This is a Limited Pre-Renovation Asbestos and Lead Paint Survey Report for the C.W. (Bill) Young, Bay Pines VA Medical Center in Bay Pines, Florida, prepared by Terracon Consultants, Inc. for Above Group Inc. The survey was conducted on December 17-18, 2024, and June 12, 2025, to identify asbestos-containing materials (ACM) and lead-based paint in designated Building 100 areas scheduled for renovation to install new PET/CT equipment. The survey covered interior areas including rooms 2C118, 2C107, 2C107A, 2C112D, 2C129, SC120, 2C121, 2C124, 2C125, and various hallways, with floor finishes of vinyl tile, faux wood plank, carpet, and carpet tile; wall finishes of painted drywall, vinyl cove base, ceramic tile, and plastic wall panels; and suspended ceiling systems.
The asbestos survey identified 29 homogeneous areas with 79 bulk samples collected and analyzed. Results detected asbestos in multiple materials classified as Non-Friable Category I (NESHAP/OSHA classification), including 3-5% chrysotile in mixed yellow/black mastics under vinyl floor tiles and carpet (approximately 1,414 square feet total), 2-10% chrysotile in white paper-wrapped thermal system insulation (TSI) on mechanical equipment (80 linear feet total), 2% chrysotile in tan duct mastic (20 linear feet), and 20 wood interior doors assumed to contain asbestos. The lead paint survey of eight samples showed no detectable lead concentrations above laboratory reporting limits. All identified asbestos-containing materials require removal by a Florida-licensed asbestos abatement contractor as OSHA Class II work activities prior to renovation, with compliance required under EPA NESHAP regulations (40 CFR 61, Subpart M) and Florida Department of Environmental Protection requirements, including third-party air monitoring during abatement. The survey was limited to accessible areas, and additional suspect materials may exist in concealed locations.
View the file
Other files
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Limited Pre-Renovation Asbestos and Lead Paint Survey Report
C.W. (Bill) Young, Bay Pines VA Medical Center
Project No. 516-CSI-134 –New 1.5T PET/CT 10000 Bay Pines Boulevard
Bay Pines, Florida 33744
August 27, 2025 Terracon Project No. H4247213, Revised
Prepared for:
Above Group Inc.
400 E. Pratt Street, 8th Floor
Baltimore, MD 21202
Prepared by:
Terracon Consultants, Inc.
Tampa, Florida
5463 West Waters Avenue, Suite 830
Tampa, Florida 33634
P (813) 221-0050
F (813) 221-0051
Terracon.com
Facilities | Environmental | Geotechnical | Materials
Above Group, Inc.
400 E. Pratt Street, 8th Floor
Baltimore, MD 21202
Attn: Ms. Jennifer Knight
P: (405) 206-0437
E: jknight@abovegroupinc.com
RE: Limited Pre-Renovation Asbestos and Lead Paint Survey Report
C.W. (Bill) Young, Bay Pines VA Medical Center
Project No. 516-CSI-134 – Site Prep for the Installation of New PET/CT
Designated Building 100 Areas
10000 Bay Pines Boulevard
Terracon Report No. H4247213, Revised
Dear Ms. Knight:
Terracon Consultants, Inc. is pleased to submit the attached report to Above Group, Inc. (Client). The purpose of this report is to present the results of a limited pre-renovation asbestos and lead paint survey performed within the designated areas of the C.W. (Bill) Young, Bay Pines VA Medical Center located in
Bay Pines, Florida. This survey was conducted in general accordance with PH4247213, dated July 1, 2024. Terracon understands this survey was requested in connection with the installation of PET/CT equipment within the designated areas of Building 100 of the subject structure.
Based on the laboratory results, asbestos was detected in building materials assessed during our survey. Laboratory analysis of the paint chip samples indicated lead was not detected in samples above the laboratory detection/reporting limit. Please refer to the attached report for further details.
Terracon appreciates the opportunity to provide this service to Above Group, Inc. If you have any questions regarding this report, or if you need assistance with project oversight and sampling during renovation, please contact the undersigned at 727-470-1104.
Sincerely, Terracon Consultants, Inc.
Florida Asbestos Business License Number ZA-337
Karl Kologiski Mark Fricke, CIH, CSP, LAC AHERA Building Inspector FL Licensed Asbestos Consultant AX132 mailto:jknight@abovegroupinc.com Kologiski, Karl V Rectangle
Kologiski, Karl V Rectangle
Kologiski, Karl V Stamp
Facilities | Environmental | Geotechnical | Materials 1
TABLE OF CONTENTS
Page
1.0 INTRODUCTION
1.1 Project Objective
1.2 Reliance
2.0 BUILDING DESCRIPTION
3.0 ASBESTOS FIELD ACTIVITIES
3.1 Visual Assessment
3.2 Physical Assessment
3.3 Sample Collection
3.4 Sample Analysis
4.0 LEAD-BASED PAINT FIELD ACTIVITIES
4.1 Visual Observations
4.2 Visual Assessment
4.3 Sample Collection
4.4 Sample Analysis
5.0 ASBESTOS REGULATORY OVERVIEW
6.0 LEAD-BASED PAINT REGULATORY OVERVIEW
7.0 ASBESTOS FINDINGS AND RECOMMENDATIONS
7.1 Findings
7.2 Recommendations
8.0 LEAD-BASED PAINT FINDINGS AND RECOMMENDATIONS
8.1 Findings
9.0 LIMITATIONS/GENERAL COMMENTS
APPENDIX A ASBESTOS ANALYTICAL LABORATORY RESULTS
APPENDIX B LEAD PAINT ANALYTICAL LABORATORY RESULTS
APPENDIX C REPRESENTATIVE PHOTOGRAPHS
APPENDIX D LICENSES AND CERTIFICATIONS
APPENDIX E ASBESTOS SAMPLE LOCATIONS
Asbestos and Lead Paint Survey Report
C.W. (Bill) Young, Bay Pines VA Medical Center
10000 Bay Pines Boulevard
Terracon Project No. H4247213 (Revised)
1.0 INTRODUCTION
Terracon Consultants, Inc. (Terracon) conducted a limited pre-renovation asbestos survey, and limited lead paint survey of the designated Building 100 areas of the C.W. (Bill) Young, Bay Pines VA Medical
Center in Bay Pines, Florida. Surveys and sampling were limited to suspect materials located within interior areas that are part of the PET/CT installation in the designated areas.
The survey was conducted from December 17-18, 2024 and June 12, 2025, by Terracon representative
Mr. Karl Kologiski, an Asbestos Hazard Emergency Response Act (AHERA)-accredited asbestos inspector in general accordance with Terracon Proposal PH4247213, dated July 1, 2024. Although reasonable effort was made to survey all accessible suspect materials within the designated interior and roof locations, additional suspect but un-sampled materials could be located in walls, in voids, or in other inaccessible or concealed areas. Applicable licenses and certifications are presented in Appendix D.
Homogeneous areas of suspected asbestos-containing materials (ACM) and suspect lead paint were visually identified, surveyed, and documented. Asbestos sampling was performed in general accordance with the United States (U.S.) Environmental Protection Agency (EPA) 40 Code of Federal Regulations
(CFR) Part 763 Subpart E 763, known as AHERA. Suspect lead paint samples were obtained from representative surfaces potentially containing lead coatings.
1.1 Project Objective
Terracon’s services were performed to accommodate planned renovation activities and to satisfy requirements of the EPA regulation 40 CFR 61, Subpart M, National Emission Standards for Hazardous
Air Pollutants (NESHAP). NESHAP regulations prohibit the release of asbestos fibers to the atmosphere during renovation or demolition activities. The asbestos NESHAP requires that potentially regulated ACM
(RACM) be identified, classified, and quantified prior to planned disturbances or demolition activities.
Lead paint testing was performed to comply with applicable sections of the U.S. Occupational Safety and
Health Administration (OSHA) Lead Standard (29 CFR 1926.62) for disturbance of paint/coatings with lead that will be encountered during renovation or demolition activities.
1.2 Reliance
This report is for the exclusive use of Above Group, Inc. (Above Group) for the project being discussed.
Reliance by any other party on this report is prohibited without written authorization of Terracon and
Above Group. Reliance on this report by Above Group and all authorized parties will be subject to the terms, conditions, and limitations stated in the proposal, this report, and the existing agreement between Above Group and Terracon. The limitations of liability defined in Terracon’s Agreement for
Services is the aggregate limit of Terracon’s liability to Above Group.
Asbestos & Lead Paint Survey Report
Project No. 516-CSI-134 – Site Prep for the Installation of New PET/CT
Bay Pines VA Hospital ■ Bay Pines, Florida
August 27, 2025 ■ Terracon Project No. H4247213 Revised
Facilities | Environmental | Geotechnical | Materials 2
2.0 BUILDING DESCRIPTION
The designated interior areas of Building 100 included in the survey consisted of the mechanical system and the following rooms: 2C118, 2C107 & 2C107A, 2C112D, 2C129, SC120, 2C121, 2C124, 2C125 ,Hallways C2-47, C2-49, C2-50 C2-52 and mechanical system mezzanine. Interior floor finishes of the Building 100 areas in the subject areas included vinyl floor tile, faux wood plank, carpet, and carpet tile. Wall finishes included painted drywall - joint compound, vinyl cove base, ceramic tile, and plastic wall panel. Ceilings consisted of a suspended ceiling grid and ceiling tiles.
3.0 ASBESTOS FIELD ACTIVITIES
The asbestos portion of the survey was conducted on December 17-18, 2024 and June 12, 2025, by
Terracon representative Mr. Karl Kologiski an AHERA-accredited asbestos inspector. A copy of the inspector certificates and applicable licenses are attached as Appendix F. The survey was conducted in general accordance with the sample collection protocols established in EPA 40 CFR Part 763 Subpart E
763.86, AHERA. A summary of survey activities is provided below.
3.1 Visual Assessment
Survey activities were initiated with limited visual observations of the accessible, designated areas to identify homogeneous areas of suspect ACM. A homogeneous area (HA) consists of building materials that appear similar throughout in terms of color and texture with consideration given to the date of application. The limited assessment was conducted in readily accessible areas of the buildings.
3.2 Physical Assessment
A physical assessment of each homogeneous area of suspect ACM was conducted to assess the friability and condition of the materials. A friable material is defined by the EPA as a material which can be crumbled, pulverized, or reduced to powder by hand pressure when dry. Friability was assessed by physically touching suspect materials.
3.3 Sample Collection
Based on results of the visual observations, bulk samples of suspect ACM were collected in general accordance with AHERA sampling protocols. Samples of suspect materials were collected in randomly selected locations in each homogeneous area. Samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker.
The selection of sample locations and frequency of sampling were based on Terracon’s observations and the assumption that like materials in the same area are homogeneous in content. A total of seventy-nine (79) bulk samples were collected by Terracon from twenty-nine (29) homogeneous areas of suspect ACM.
Project No. 516-CSI-134 – Site Prep for the Installation of New PET/CT
Facilities | Environmental | Geotechnical | Materials 3
3.4 Sample Analysis
Bulk samples were submitted under secure chain of custody protocols to Scientific Analytical Institute
(SAI) of Greensboro North Carolina for analysis by polarized light microscopy with dispersion staining techniques per EPA methodology 600/R-93/116. The percentage of asbestos, where applicable was determined by microscopic visual estimation. SAI is accredited under the National Voluntary
Laboratory Accreditation Program (NVLAP) Accreditation No. 200664-0. Asbestos laboratory data is presented in Appendix A. Representative asbestos sample photographs are presented in Appendix C.
Asbestos sample locations are presented in Appendix E.
4.0 LEADPAINT FIELD ACTIVITES
4.1 Visual Observations
The lead paint survey was limited to readily observable and accessible surfaces that may be disturbed during the planned renovations. Terracon cannot guarantee that all lead paint coated surfaces were identified during our survey as some lead paint may be hidden from sight or in inaccessible locations, or the homogeneous construction areas identified may not be truly homogeneous. This limited lead paint survey was not performed in accordance with U.S. Department of Housing and Urban
Development (HUD) Guidelines for the Evaluation and Control of Lead-Based Paint (LBP)
Hazards in Housing or applicable to EPA 40 CFR 745 requirements. It should be understood that this limited lead paint survey was not considered to be comprehensive in nature, and the results are not intended to be used to determine all lead hazards, develop lead abatement plans, or prepare detailed cost estimates for lead abatement.
4.2 Visual Assessment
A visual assessment of each unique combination, defined as a color, component, and substrate, of suspect lead paint was conducted in addition to an assessment of the paint condition.
4.3 Sample Collection
A total of eight (8) paint chip samples of suspect lead paint were collected. Paint chip samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker.
Laboratory results are presented in Appendix B. Representative lead paint sample photographs are presented in Appendix C.
4.4 Sample Analysis
Paint chip samples were submitted under chain of custody to Scientific Analytical Institute (SAI) for analysis by flame atomic absorption spectrometry per EPA SW-846/3050B/7000B. SAI is accredited under the Environmental Lead Laboratory Accreditation Program (ELLAP) (Accreditation No. 173190).
Project No. 516-CSI-134 – Site Prep for the Installation of New PET/CT
Facilities | Environmental | Geotechnical | Materials 4
5.0 ASBESTOS REGULATORY OVERVIEW
The asbestos NESHAP (40 CFR Part 61, Subpart M) regulates asbestos fiber emissions and asbestos waste disposal practices. The NESHAP regulation also requires the identification and classification of existing ACM according to friability prior to demolition or renovation activity.
Under NESHAP, asbestos-containing building materials are classified as:
1. Friable ACM, or
2. Category I Non-Friable ACM, or
3. Category II Non-Friable ACM.
Friable materials are those that, when dry, may be crumbled, pulverized, or reduced to powder by hand pressure. Category I Non-Friable ACM includes packings, gaskets, resilient floor coverings and asphalt roofing products containing more than 1% asbestos. Category II Non-Friable ACM are any materials other than Category I Non-Friable ACM that contain more than 1% asbestos.
Under NESHAP, Regulated Asbestos-Containing Materials (RACM are classified as:
1. Friable ACM.
2. Category I Non-Friable ACM that is in poor condition and/or has become friable.
3. Category I Non-Friable ACM that will or has been subjected to sanding, grinding, cutting, or abrading.
4. Category II Non-Friable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act upon the material in the course of renovation or demolition operations.
In the State of Florida, asbestos activities are regulated by the Florida Department of Environmental
Protection (FDEP). Some counties have developed an enforcement division to carry out the responsibilities of the FDEP and have developed environmental and asbestos ordinances in which additional compliance is required. Since the facility is located in Pinellas County Florida, the NESHAP regulations are under the authority of the Pinellas County Air Quality Division (727-464-4425).
Per the NESHAP, RACM must be removed prior to renovation or demolition activities that will disturb the materials. Removal of any ACM or RACM must be conducted by a State of Florida-licensed asbestos abatement contractor, in compliance with Florida Statute (F.S) 469.001-014. In addition, third party air monitoring should be performed during and following the abatement.
The OSHA Asbestos standard for construction (29 CFR 1926.1101) regulates employee workplace exposure to asbestos. The OSHA standard has (2) Permissible Exposure Limits (PEL) that require employee exposure to airborne asbestos fibers be maintained below 0.1 asbestos fibers per cubic centimeter of air (0.1 f/cc) for an 8-hour Time-Weighted Average (8-Hr. TWA) and 1.0 f/cc for a 30-minute TWA (Excursion Limit). The OSHA standard classifies construction and maintenance activities which could disturb ACM and specifies work practices and precautions which employers must follow when engaging in each class of regulated work.
Project No. 516-CSI-134 – Site Prep for the Installation of New PET/CT
Facilities | Environmental | Geotechnical | Materials 5
6.0 LEAD-CONTAINING PAINT REGULATORY OVERVIEW
Lead is regulated by the EPA, HUD, Florida Department of Environmental Protection (FDEP) and OSHA.
The EPA and FDEP regulate lead use, removal, and disposal, and OSHA regulates lead exposure to workers.
The EPA defines Lead-Based Paint (LBP) as any paint, varnish, stain, or other applied coating that contains lead equal to or greater than 1.0 mg/cm2, 5,000 mg/kg, or 0.5% by dry weight as determined by laboratory analysis.
For the purpose of the OSHA lead standard, lead-containing materials includes any detectable concentrations of metallic lead, all inorganic lead compounds, and organic lead soaps. A synopsis of the OSHA regulations (29 CFR 1926.62) and the applicability are as follows:
The OSHA Lead Standard for Construction (29 CFR 1926.62) applies to all construction work where an employee may be occupationally exposed to lead. All work related to construction, alteration, or repair
(including painting and decorating) is included. The Lead-in-Construction standard applies to any detectable concentration of lead in paint, as even small concentrations of lead can result in unacceptable employee exposures depending upon on the method of disturbance-removal and other workplace conditions.
Under this standard, construction includes, but is not limited to, the following:
◼ Demolition or salvage of structures where lead or materials containing lead are present.
◼ Removal or encapsulation of materials containing lead.
◼ New construction, alteration, repair, or renovation of structures, substrates, or portions containing lead, or materials containing lead.
◼ Installation of products containing lead
◼ Lead contamination/emergency clean-up.
◼ Transportation, disposal, storage, or containment of lead or materials containing lead on the site or location at which construction activities are performed.
◼ Maintenance operations associated with construction activities described above.
7.0 FINDINGS AND RECOMMENDATIONS – ASBESTOS
7.1 Findings
HA#
HA
DESCRIPTION
SAMPLE
LOCATIONS
NESHAP / OSHA
CLASSIFICATION
CONDITION
MATERIAL
LOCATION
QUANTITY
(SF)
ASBESTOS TYPE
CX1
Non-asbestos 12” white/gray streak VFT/ and mixed yellow/black asbestos mastic C2-51 HA
2C-122D
C2-51 Non-Friable Cat I Good
2C-122D
C2-51
C2-50
C2-49
C2-47
3% Chrysotile -
Mixed Yellow/Black
Mastic
CX2
Non-asbestos 12” off white VFT and asbestos black mastic / 2C-10712
2C-107
2C107A Non-Friable Cat I Good
2C-107
2C107A
5% Chrysotile -
Mastic
CX4
Non asbestos 12” blue
VFT and mixed yellow/black asbestos mastic / 2C122D
2C-122D Non-Friable Cat I Good 2C-122D
(Patch)
2% Chrysotile -
Mixed Yellow/Black
Mastic
CX10
24” Black Carpet Squares w/ Green & Black Mastic 2C-120 Non-Friable Cat I Good 2C-120 140
2% Chrysotile -
Mixed Green/Black
Mastic
CX11
Non-asbestos blue sq pattern carpet and mixed yellow/black asbestos mastic / 2C121
2C-121 Non-Friable Cat I Good 2C-121 180
3% Chrysotile -
Mixed Yellow/Black
Mastic
Project No. 516-CSI-134 – Site Prep for the Installation of New PET/CT
Facilities | Environmental | Geotechnical | Materials 6
HA#
HA
DESCRIPTION
SAMPLE
LOCATIONS
NESHAP / OSHA
CLASSIFICATION
CONDITION
MATERIAL
LOCATION
QUANTITY
(SF)
ASBESTOS TYPE
CX24 4” White paper wrap TSI
Upper
Mechanical
Mezzanine
Non-Friable Cat I Good
Upper
Mechanical
Mezzanine
60 Liner
Feet
7-10% Chrysotile -
White Mastic
CX27 Tan Duct Mastic
Upper
Mechanical
Mezzanine
Non-Friable Cat I Good
Upper
Mechanical
Mezzanine
20 Liner
Feet 2% Chrysotile
CX30 Wood Interior Door NA Assumed ACM Good Throughout
Work Area 20 Doors NA
Laboratory results are presented in Appendix A. Representative asbestos sample photographs are presented in Appendix C. Asbestos sample locations are presented in Appendix E. Estimated quantities are based on a cursory field evaluation, and actual quantities may vary significantly, especially if asbestos containing materials are present in hidden and/or inaccessible areas not evaluated as part of this survey. It should be noted that the quantity provided is an estimate only and should not be used for bidding or notification purposes. It should be noted that suspect materials other than those identified may exist. Should suspect materials other than those which were identified during this survey be uncovered prior to or during the renovation process, those materials should be assumed asbestos-containing until sampling and analysis can confirm or refute their asbestos content.
7.2 Recommendations
Non-Friable Cat I Mixed Yellow/Black Mastics In its current state, the noted mastics can be considered a Non-Friable, Category I ACM. As such, this material should be removed by a Florida licensed asbestos abatement contractor as an OSHA Class II work activity. In addition, The State of Florida requires any concrete waste (CMU, Slab, etc.) to be free of any ACM material (paint, mastics, etc.) prior to disposal or recycling.
Non-Friable Cat I, Tan Duct Mastic and White TSI Mastic
In its current state, the noted mastics can be considered a Non-Friable, Category I ACM. As such, this material should be removed by a Florida licensed asbestos abatement contractor as an OSHA Class II work activity. In addition, The State of Florida requires any concrete waste (CMU, Slab, etc.) to be free of any ACM material (paint, mastics, etc.) prior to disposal or recycling.
Assumed ACM, Interior Door and Frame Assemblies
Due to the on-going operations in the designated areas of the PET/CT scan areas, the doors and frames could not be tested for asbestos at the time of the survey. The metal door frames were labeled as fire-rated door frames, however there were no markings on the wood doors. The door and frame assemblies are assumed to be asbestos containing and are to be treated as such, until the designated areas are vacated, at which time, the doors and frames can be drilled so that the interior contents can be sampled for asbestos content.
Terracon recommends that if any materials not sampled in this survey are uncovered during planned work that these suspect materials should be considered asbestos containing until sampled and proven otherwise. It is recommended that any materials identified as containing asbestos be removed prior to renovation or demolition activities by a Florida-Licensed Asbestos Abatement Contractor. We also recommend direct contact with the Pinellas County Air Quality Division (727-464-4425) for confirmation and clarifications of their asbestos program requirements.
Project No. 516-CSI-134 – Site Prep for the Installation of New PET/CT
Facilities | Environmental | Geotechnical | Materials 7
8.0 FINDINGS AND RECOMMENDATIONS – Lead Paint
8.1 Findings
Detectable concentrations of lead were not identified in the various coatings evaluated during the assessment. The lead paint summary table presented below summarizes the results of the 7 paint chip samples:
Sample
ID
Sample
Location Item Substrate Color
Reporting
Limit
(PPM)
Concentration
(PPM)
Paint Chip
Results %
Weight
CP-1 2C-122D Wall Drywall Blue 38 <38 0.0038
CP-2 2C-118 Wall Drywall Brown 53 <53 0.0053
CP-3 2C-124 Wall Drywall Teal 48 <48 0.0048
CP4 2C-48 Wall Drywall Green 46 <46 0.0046
CP5 2C-107 Wall Drywall Off White 62 <62 0.0062
CP6 2C-50 Wall Drywall Beige 35 <35 0.0035
CP7 2C-107 Door Frame Metal White 40 <86 0.0086
CP8 2C-120 Wall Drywall Purple 43 <43 0.0043
9.0 LIMITATIONS/GENERAL COMMENTS
This Limited Interior Pre-Renovation Asbestos and Lead Paint Survey was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, conclusions, and recommendations expressed in this report are based on conditions observed during our survey of the designated areas. The information contained in this report is relevant to the date on which this survey was conducted and should not be relied upon to represent conditions at a later date.
This report has been prepared on behalf of and exclusively for use by Above Group for specific application to their project as discussed. This report is not a bidding document. Contractors or consultants reviewing this report must draw their own conclusions regarding further investigation or remediation deemed necessary. Terracon does not warrant the work of regulatory agencies, laboratories or other third parties supplying information which may have been used in the preparation of this report.
No warranty, express or implied, is made.
APPENDIX A
ASBESTOS ANALYTICAL LABORATORY RESULTS
Bulk Asbestos Analysis By Polarized Light Microscopy EPA Method: 600/R-93/116 and
40 CFR, Part 763, Subpart E, App.E
Lab Order ID:Attn: 10071152Customer: Terracon 5463 W Waters Ave Suite 830 Tampa, FL 33634-1253
Analysis:
Date Received:
Date Amended:
Karl Kologiski
PLM
12/19/2024
Project: Bay Pines VA CT - H4247213 Date Reported: 12/26/2024
01/23/2025
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos
Fibrous Components
Non-Fibrous Components Treatment
Attributes
CX1-1 - A
10071152_0001
12" white/gray streak
VFT/2C-122D
None Detected 100% Other
Non-Fibrous
Dissolved
White
Homogeneous tile
CX1-1 - B
10071152_0053
12" white/gray streak
VFT/2C-122D
None Detected 100% Other
Non-Fibrous
Dissolved
Yellow
Homogeneous mastic
CX1-2 - A
10071152_0002
12" white/gray streak
VFT/2C-51 HA
None Detected 100% Other
Non-Fibrous
Dissolved
White
Homogeneous tile
CX1-2 - B
10071152_0054
12" white/gray streak
VFT/2C-51 HA
3% Chrysotile 97% Other
Non-Fibrous
Dissolved
Yellow, Black
Homogeneous mixed mastic
CX1-3 - A
10071152_0003
12" white/gray streak
VFT/2C-51 HA
None Detected 100% Other
Non-Fibrous
Dissolved
White
Homogeneous tile
CX1-3 - B
10071152_0055
12" white/gray streak
VFT/2C-51 HA
3% Chrysotile 97% Other
Non-Fibrous
Dissolved
Yellow, Black
Homogeneous mixed mastic
CX2-4 - A
10071152_0004
12" off white VFT/2C-107
None Detected 100% Other
Non-Fibrous
Dissolved
White
Homogeneous tile
CX2-4 - B
10071152_0056
12" off white VFT/2C-107
5% Chrysotile 95% Other
Non-Fibrous
Dissolved
Black
Homogeneous mastic
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.
Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Charmel Dozier (85)
Analyst Approved Signatory
Page 1 of 11P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
EPA Method: 600/R-93/116 and
40 CFR, Part 763, Subpart E, App.E
Lab Order ID:Attn: 10071152Customer: Terracon 5463 W Waters Ave Suite 830 Tampa, FL 33634-1253
Analysis:
Date Received:
Date Amended:
Karl Kologiski
PLM
12/19/2024
Project: Bay Pines VA CT - H4247213 Date Reported: 12/26/2024
01/23/2025
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos
Fibrous Components
Non-Fibrous Components Treatment
Attributes
CX2-5 - A
10071152_0005
12" off white VFT/2C-107A
None Detected 100% Other
Non-Fibrous
Dissolved
White
Homogeneous tile
CX2-5 - B
10071152_0057
12" off white VFT/2C-107A
5% Chrysotile 95% Other
Non-Fibrous
Dissolved
Black
Homogeneous mastic
CX2-6 - A
10071152_0006
12" off white VFT/2C-107A
None Detected 100% Other
Non-Fibrous
Dissolved
White
Homogeneous tile
CX2-6 - B
10071152_0058
12" off white VFT/2C-107A
5% Chrysotile 95% Other
Non-Fibrous
Dissolved
Black
Homogeneous mastic
CX3-7 - A
10071152_0007
6" faux wood plank/2C-118
None Detected 100% Other
Non-Fibrous
Dissolved
Brown
Homogeneous wood plank
CX3-7 - B
10071152_0059
6" faux wood plank/2C-118
None Detected 100% Other
Non-Fibrous
Dissolved
Yellow
Homogeneous mastic
CX3-8 - A
10071152_0008
6" faux wood plank/2C-124
None Detected 100% Other
Non-Fibrous
Dissolved
Brown
Homogeneous wood plank
CX3-8 - B
10071152_0060
6" faux wood plank/2C-124
None Detected 100% Other
Non-Fibrous
Crushed, Dissolved
Yellow, Gray
Homogeneous mastic/leveling
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.
Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Charmel Dozier (85)
Page 2 of 11P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
EPA Method: 600/R-93/116 and
40 CFR, Part 763, Subpart E, App.E
Lab Order ID:Attn: 10071152Customer: Terracon 5463 W Waters Ave Suite 830 Tampa, FL 33634-1253
Analysis:
Date Received:
Date Amended:
Karl Kologiski
PLM
12/19/2024
Project: Bay Pines VA CT - H4247213 Date Reported: 12/26/2024
01/23/2025
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos
Fibrous Components
Non-Fibrous Components Treatment
Attributes
CX3-9 - A
10071152_0009
6" faux wood plank/2C-125
None Detected 100% Other
Non-Fibrous
Dissolved
Brown
Homogeneous wood plank
CX3-9 - B
10071152_0061
6" faux wood plank/2C-125
None Detected 100% Other
Non-Fibrous
Crushed, Dissolved
Yellow, Gray
Homogeneous mastic/leveling
CX4-10 - A
10071152_0010
12" blue VFT/2C122D
None Detected 100% Other
Non-Fibrous
Dissolved
Blue
Homogeneous tile
CX4-10 - B
10071152_0062
12" blue VFT/2C122D
2% Chrysotile 98% Other
Non-Fibrous
Dissolved
Black, Yellow
Homogeneous mixed mastic
CX4-11 - A
10071152_0011
12" blue VFT/2C122D
None Detected 100% Other
Non-Fibrous
Dissolved
Blue
Homogeneous tile
CX4-11 - B
10071152_0063
12" blue VFT/2C122D
2% Chrysotile 98% Other
Non-Fibrous
Dissolved
Black, Yellow
Homogeneous mixed mastic
CX5-12 - A
10071152_0012
4" tan cove base/2C122D
None Detected 100% Other
Non-Fibrous
Dissolved
Blue
Homogeneous cove base
CX5-12 - B
10071152_0064
4" tan cove base/2C122D
None Detected 100% Other
Non-Fibrous
Dissolved
Yellow
Homogeneous mastic
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.
Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Charmel Dozier (85)
Page 3 of 11P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
EPA Method: 600/R-93/116 and
40 CFR, Part 763, Subpart E, App.E
Lab Order ID:Attn: 10071152Customer: Terracon 5463 W Waters Ave Suite 830 Tampa, FL 33634-1253
Analysis:
Date Received:
Date Amended:
Karl Kologiski
PLM
12/19/2024
Project: Bay Pines VA CT - H4247213 Date Reported: 12/26/2024
01/23/2025
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos
Fibrous Components
Non-Fibrous Components Treatment
Attributes
CX5-13 - A
10071152_0013
4" tan cove base/2C122D
None Detected 100% Other
Non-Fibrous
Dissolved
Blue
Homogeneous cove base
CX5-13 - B
10071152_0065
4" tan cove base/2C122D
None Detected 100% Other
Non-Fibrous
Dissolved
Yellow
Homogeneous mastic
CX6-14
10071152_0014
DW/JC/2C118
None Detected 10% Cellulose 90% Other
Fibrous
Crushed
White
Homogeneous drywall: none detected, joint compound: none detected
CX6-15
10071152_0015
DW/JC/2C107
None Detected 10% Cellulose 90% Other
Fibrous
Crushed
White
Homogeneous drywall: none detected, joint compound: none detected
CX6-16
10071152_0016
DW/JC/2C122D
None Detected 10% Cellulose 90% Other
Fibrous
Crushed
White
Homogeneous drywall: none detected, joint compound: none detected
CX6-17
10071152_0017
DW/JC/2C121
None Detected 10% Cellulose 90% Other
Fibrous
Crushed
White
Homogeneous drywall: none detected, joint compound: none detected
CX6-18
10071152_0018
DW/JC/2C-51-hallway
None Detected 10% Cellulose 90% Other
Fibrous
Crushed
White
Homogeneous drywall: none detected, joint compound: none detected
CX6-19
10071152_0019
DW/JC/C2-48
None Detected 10% Cellulose 90% Other
Fibrous
Crushed
White
Homogeneous drywall: none detected, joint compound: none detected
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.
Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Charmel Dozier (85)
Page 4 of 11P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
EPA Method: 600/R-93/116 and
40 CFR, Part 763, Subpart E, App.E
Lab Order ID:Attn: 10071152Customer: Terracon 5463 W Waters Ave Suite 830 Tampa, FL 33634-1253
Analysis:
Date Received:
Date Amended:
Karl Kologiski
PLM
12/19/2024
Project: Bay Pines VA CT - H4247213 Date Reported: 12/26/2024
01/23/2025
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos
Fibrous Components
Non-Fibrous Components Treatment
Attributes
CX7-20 - A
10071152_0020
4" tan ceramic wall tile/2C122D
None Detected 100% Other
Non-Fibrous
Crushed
White
Homogeneous ceramic tile
CX7-20 - B
10071152_0066
4" tan ceramic wall tile/2C122D
None Detected 100% Other
Non-Fibrous
Dissolved
White
Homogeneous adhesive
CX7-21 - A
10071152_0021
4" tan ceramic wall tile/2C122D
None Detected 100% Other
Non-Fibrous
Crushed
White
Homogeneous ceramic tile
CX7-21 - B
10071152_0067
4" tan ceramic wall tile/2C122D
None Detected 100% Other
Non-Fibrous
Crushed
White
Homogeneous grout
CX8-22 - A
10071152_0022
4" brown cove base/2C107A
None Detected 100% Other
Non-Fibrous
Dissolved
Brown
Homogeneous cove base
CX8-22 - B
10071152_0068
4" brown cove base/2C107A
None Detected 100% Other
Non-Fibrous
Dissolved
Yellow
Homogeneous mastic
CX8-23 - A
10071152_0023
4" brown cove base/2C-121
None Detected 100% Other
Non-Fibrous
Dissolved
Brown
Homogeneous cove base
CX8-23 - B
10071152_0069
4" brown cove base/2C-121
None Detected 100% Other
Non-Fibrous
Dissolved
Yellow
Homogeneous mastic
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.
Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Charmel Dozier (85)
Page 5 of 11P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
EPA Method: 600/R-93/116 and
40 CFR, Part 763, Subpart E, App.E
Lab Order ID:Attn: 10071152Customer: Terracon 5463 W Waters Ave Suite 830 Tampa, FL 33634-1253
Analysis:
Date Received:
Date Amended:
Karl Kologiski
PLM
12/19/2024
Project: Bay Pines VA CT - H4247213 Date Reported: 12/26/2024
01/23/2025
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos
Fibrous Components
Non-Fibrous Components Treatment
Attributes
CX8-24 - A
10071152_0024
4" brown cove base/C2-51-hallway
None Detected 100% Other
Non-Fibrous
Dissolved
Brown
Homogeneous cove base
CX8-24 - B
10071152_0070
4" brown cove base/C2-51-hallway
None Detected 100% Other
Non-Fibrous
Dissolved
Yellow
Homogeneous mastic
CX9-25
10071152_0025
24" pinhole Ct/2C 121
None Detected 50% 25%
Mineral Wool Cellulose
25% Other
Fibrous
Teased
White
Homogeneous
CX9-26
10071152_0026
24" pinhole Ct/2C 118
None Detected 50% 25%
Mineral Wool Cellulose
25% Other
Fibrous
Teased
White
Homogeneous
CX10-27 - A
10071152_0027
24" black carpet sq/2C-120
None Detected 70% Synthetic Fibers 30% Other
Fibrous
Ashed
Black, Blue
Homogeneous carpet
CX10-27 - B
10071152_0071
24" black carpet sq/2C-120
None Detected 100% Other
Non-Fibrous
Dissolved
Green
Homogeneous mastic
CX10-28 - A
10071152_0028
24" black carpet sq/2C-120
None Detected 70% Synthetic Fibers 30% Other
Fibrous
Ashed
Black, Blue
Homogeneous carpet
CX10-28 - B
10071152_0072
24" black carpet sq/2C-120
2% Chrysotile 98% Other
Non-Fibrous
Dissolved
Green, Black
Homogeneous mastic - amended - additional QC requested
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.
Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Charmel Dozier (85)
Page 6 of 11P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
EPA Method: 600/R-93/116 and
40 CFR, Part 763, Subpart E, App.E
Lab Order ID:Attn: 10071152Customer: Terracon 5463 W Waters Ave Suite 830 Tampa, FL 33634-1253
Analysis:
Date Received:
Date Amended:
Karl Kologiski
PLM
12/19/2024
Project: Bay Pines VA CT - H4247213 Date Reported: 12/26/2024
01/23/2025
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos
Fibrous Components
Non-Fibrous Components Treatment
Attributes
CX11-29 - A
10071152_0029
Blue sq pattern carpet/2C121
None Detected 70% Synthetic Fibers 30% Other
Fibrous
Ashed
Blue
Homogeneous carpet
CX11-29 - B
10071152_0073
Blue sq pattern carpet/2C121
None Detected 100% Other
Non-Fibrous
Dissolved
Yellow
Homogeneous mastic
CX11-29 - C
10071152_0074
Blue sq pattern carpet/2C121
None Detected 100% Other
Non-Fibrous
Dissolved
White
Homogeneous tile
CX11-29 - D
10071152_0075
Blue sq pattern carpet/2C121
3% Chrysotile 97% Other
Non-Fibrous
Dissolved
Yellow, Black
Homogeneous mixed mastic
CX11-30 - A
10071152_0030
Blue sq pattern carpet/2C121
None Detected 70% Synthetic Fibers 30% Other
Fibrous
Ashed
Blue
Homogeneous carpet
CX11-30 - B
10071152_0076
Blue sq pattern carpet/2C121
None Detected 100% Other
Non-Fibrous
Dissolved
Yellow
Homogeneous mastic
CX11-30 - C
10071152_0077
Blue sq pattern carpet/2C121
None Detected 100% Other
Non-Fibrous
Dissolved
White
Homogeneous tile
CX11-30 - D
10071152_0078
Blue sq pattern carpet/2C121
3% Chrysotile 97% Other
Non-Fibrous
Dissolved
Black, Yellow
Homogeneous mixed mastic
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.
Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Charmel Dozier (85)
Page 7 of 11P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
EPA Method: 600/R-93/116 and
40 CFR, Part 763, Subpart E, App.E
Lab Order ID:Attn: 10071152Customer: Terracon 5463 W Waters Ave Suite 830 Tampa, FL 33634-1253
Analysis:
Date Received:
Date Amended:
Karl Kologiski
PLM
12/19/2024
Project: Bay Pines VA CT - H4247213 Date Reported: 12/26/2024
01/23/2025
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos
Fibrous Components
Non-Fibrous Components Treatment
Attributes
CX12-31
10071152_0031
24" random divet CT/2C- 122D
None Detected 55% 15%
Cellulose Mineral Wool
30% Other
Fibrous
Teased
White
Homogeneous
CX12-32
10071152_0032
24" random divet CT/2C-120
None Detected 55% 15%
Cellulose Mineral Wool
30% Other
Fibrous
Teased
White
Homogeneous
CX12-33
10071152_0033
24" random divet CT/2C-124
None Detected 55% 15%
Cellulose Mineral Wool
30% Other
Fibrous
Teased
White
Homogeneous
CX13-34
10071152_0034
2x4 random divit CT/C2-51 hallway
None Detected 55% 15%
Cellulose Mineral Wool
30% Other
Fibrous
Teased
White
Homogeneous
CX13-35
10071152_0035
2x4 random divit CT/C2-51 hallway
None Detected 55% 15%
Cellulose Mineral Wool
30% Other
Fibrous
Teased
White
Homogeneous
CX14-36 - A
10071152_0036
4" white cove base/C2-48
None Detected 100% Other
Non-Fibrous
Dissolved
White
Homogeneous cove base
CX14-36 - B
10071152_0085
4" white cove base/C2-48
None Detected 100% Other
Non-Fibrous
Dissolved
Yellow
Homogeneous mastic
CX14-37 - A
10071152_0037
4" white cove base/2C118
None Detected 100% Other
Non-Fibrous
Dissolved
White
Homogeneous cove base
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.
Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Charmel Dozier (85)
Page 8 of 11P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
EPA Method: 600/R-93/116 and
40 CFR, Part 763, Subpart E, App.E
Lab Order ID:Attn: 10071152Customer: Terracon 5463 W Waters Ave Suite 830 Tampa, FL 33634-1253
Analysis:
Date Received:
Date Amended:
Karl Kologiski
PLM
12/19/2024
Project: Bay Pines VA CT - H4247213 Date Reported: 12/26/2024
01/23/2025
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos
Fibrous Components
Non-Fibrous Components Treatment
Attributes
CX14-37 - B
10071152_0079
4" white cove base/2C118
None Detected 100% Other
Non-Fibrous
Dissolved
Yellow
Homogeneous mastic
CX14-38 - A
10071152_0038
4" white cove base/2C129
None Detected 100% Other
Non-Fibrous
Dissolved
White
Homogeneous cove base
CX14-38 - B
10071152_0080
4" white cove base/2C129
None Detected 100% Other
Non-Fibrous
Dissolved
Yellow
Homogeneous mastic
CX15-39
10071152_0039
Caulking - wall panel/2C118
None Detected 100% Other
Non-Fibrous
Ashed
Tan
Homogeneous
CX15-40
10071152_0040
Caulking - wall panel/2C118
None Detected 100% Other
Non-Fibrous
Ashed
Tan
Homogeneous
CX16-41
10071152_0041
24" solid ceiling tile/2C118
None Detected 40% 30%
Cellulose Mineral Wool
30% Other
Fibrous
Teased
White
Homogeneous
CX16-42
10071152_0042
24" solid ceiling tile/2C118
None Detected 40% 30%
Cellulose Mineral Wool
30% Other
Fibrous
Teased
White
Homogeneous
CX17-43 - A
10071152_0043
Plastic wall panel/2C118
None Detected 100% Other
Non-Fibrous
Ashed
White
Homogeneous wall panel
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.
Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Charmel Dozier (85)
Page 9 of 11P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
EPA Method: 600/R-93/116 and
40 CFR, Part 763, Subpart E, App.E
Lab Order ID:Attn: 10071152Customer: Terracon 5463 W Waters Ave Suite 830 Tampa, FL 33634-1253
Analysis:
Date Received:
Date Amended:
Karl Kologiski
PLM
12/19/2024
Project: Bay Pines VA CT - H4247213 Date Reported: 12/26/2024
01/23/2025
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos
Fibrous Components
Non-Fibrous Components Treatment
Attributes
CX17-43 - B
10071152_0081
Plastic wall panel/2C118
None Detected 100% Other
Non-Fibrous
Dissolved
Yellow
Homogeneous mastic
CX17-44 - A
10071152_0044
Plastic wall panel/2C118
None Detected 100% Other
Non-Fibrous
Ashed
White
Homogeneous wall panel
CX17-44 - B
10071152_0082
Plastic wall panel/2C118
None Detected 100% Other
Non-Fibrous
Dissolved
Yellow
Homogeneous mastic
CX18-45
10071152_0045
Fire stop Pu/2C120
None Detected 1% Fiber Glass 99% Other
Non-Fibrous
Dissolved
Red
Homogeneous
CX18-46
10071152_0046
Fire stop Pu/2C120
None Detected 1% Fiber Glass 99% Other
Non-Fibrous
Dissolved
Red
Homogeneous
CX19-47 - A
10071152_0047
4" faux wood plank/2C129
None Detected 100% Other
Non-Fibrous
Dissolved
Brown
Homogeneous wood plank
CX19-47 - B
10071152_0083
4" faux wood plank/2C129
None Detected 100% Other
Non-Fibrous
Crushed, Dissolved
Yellow, Gray
Homogeneous mastic/leveling
CX19-48 - A
10071152_0048
4" faux wood plank/C248
None Detected 100% Other
Non-Fibrous
Dissolved
Brown
Homogeneous wood plank
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.
Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Charmel Dozier (85)
Page 10 of 11P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
EPA Method: 600/R-93/116 and
40 CFR, Part 763, Subpart E, App.E
Lab Order ID:Attn: 10071152Customer: Terracon 5463 W Waters Ave Suite 830 Tampa, FL 33634-1253
Analysis:
Date Received:
Date Amended:
Karl Kologiski
PLM
12/19/2024
Project: Bay Pines VA CT - H4247213 Date Reported: 12/26/2024
01/23/2025
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos
Fibrous Components
Non-Fibrous Components Treatment
Attributes
CX19-48 - B
10071152_0084
4" faux wood plank/C248
None Detected 100% Other
Non-Fibrous
Dissolved, Crushed
Gray, Yellow
Homogeneous mastic/leveling
CX20-49
10071152_0049
Gray sink undercoat/2C107
None Detected 5% Cellulose 95% Other
Non-Fibrous
Dissolved
Gray
Homogeneous
CX20-50
10071152_0050
Gray sink undercoat/2C107
None Detected 5% Cellulose 95% Other
Non-Fibrous
Dissolved
Gray
Homogeneous
CX21-51
10071152_0051
Caulking back splash/2C107
None Detected 100% Other
Non-Fibrous
Dissolved
White, Tan
Homogeneous
CX21-52
10071152_0052
Caulking back splash/2C107
None Detected 100% Other
Non-Fibrous
Dissolved
Tan, White
Homogeneous
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.
Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Charmel Dozier (85)
Page 11 of 11P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
EPA Method: 600/R-93/116 and
40 CFR, Part 763, Subpart E, App.E
Lab Order ID:Attn: 10084739Customer: Terracon 5463 W Waters Ave Suite 830 Tampa, FL 33634-1253
Analysis:
Date Received:
Date Amended:
Karl Kologiski
PLM
06/16/2025
Project: Bay Pines VA PET/CT
08/11/2025
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos
Fibrous Components
Non-Fibrous Components Treatment
Attributes
CX 24 60 - A
10084739_0008
4" White paper wrap TSI elbow/T joint
10% Chrysotile 90% Other
Non-Fibrous
Ashed
White
Homogeneous mastic
CX 24 60 - B
10084739_0028
4" White paper wrap TSI elbow/T joint
None Detected 60% Cellulose 40% Other
Fibrous
Ashed
White
Homogeneous paper
CX 24 61 - A
10084739_0009
4" White paper wrap TSI elbow/T joint
10% Chrysotile 90% Other
Non-Fibrous
Ashed
White
Homogeneous mastic
CX 24 61 - B
10084739_0029
4" White paper wrap TSI elbow/T joint
None Detected 60% Cellulose 40% Other
Fibrous
Ashed
White
Homogeneous paper
CX 24 62 - A
10084739_0010
4" White paper wrap TSI elbow/T joint
10% Chrysotile 90% Other
Non-Fibrous
Ashed
White
Homogeneous mastic
CX 24 62 - B
10084739_0030
4" White paper wrap TSI elbow/T joint
None Detected 60% Cellulose 40% Other
Fibrous
Ashed
White
Homogeneous paper
CX 24 63 - A
10084739_0011
4" White paper wrap TSI elbow/T joint
7% Chrysotile 93% Other
Non-Fibrous
Ashed
White
Homogeneous mastic
CX 24 63 - B
10084739_0031
4" White paper wrap TSI elbow/T joint
None Detected 60% Cellulose 40% Other
Fibrous
Ashed
White
Homogeneous paper
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .