- New U. S. Courthouse in Harrisburg, Pennsylvania
- Solicitation number
- GS-03-P-17-AZ-C-0014
About this file
Amendment 0015
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment_0016.pdf | ||
| Proposal_Form_and_Staffing_Plan.xlsx | XLSX spreadsheet | |
| Amendment_0014.pdf | ||
| Harrisburg_Proposal_Form_12.15.17.xlsx | XLSX spreadsheet | |
| Harrisburg_Proposal_Form_10.24.17.xlsx | XLSX spreadsheet | |
| Amendment_0012.pdf | ||
| 2005_Pub_64_Vol_3_JSS_Req_&_Specs.pdf | ||
| Amendment_0011.pdf | ||
| Proposal_Form_10.16.17.xlsx | XLSX spreadsheet | |
| Amendment_0010.pdf | ||
| Amendment_0009.pdf | ||
| Proposal_Form.xlsx | XLSX spreadsheet | |
| Amendment_0008.pdf | ||
| Amendment_0007.pdf | ||
| Amendment_0006.pdf | ||
| Proposal_Form.xlsx | XLSX spreadsheet | |
| Amendment_0005.pdf | ||
| Form_DS-1_(BLANK).pdf | ||
| Amendment_0004.pdf | ||
| Amendment_0003.pdf | ||
| Amendment_0002.pdf | ||
| Amendment_0001.pdf | ||
| Attachment_3_-_Small_Business_Utilization_Form.doc | DOC document | |
| Attachment_2_-_Past_Performance_Questionnaire.doc | DOC document | |
| GSA527.pdf | ||
| Attachment_1_-_Past_Project_Form.docx | DOCX document | |
| RFP_GS-03-P-17-AZ-C-0014.pdf |
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
(a) By completing items 8 and 15, and returning or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
E. IMPORTANT: Contractor is not is required to sign this document and return copies to the issuing office.
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE
2. AMENDMENT/MODIFICATION NUMBER 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQUISITION NUMBER 5. PROJECT NUMBER (If applicable)
7. ADMINISTERED BY (If other than Item 6) CODE
STANDARD FORM 30 (REV. 11/2016)
Prescribed by GSA FAR (48 CFR) 53.243
FACILITY CODE
9A. AMENDMENT OF SOLICITATION NUMBER
9B. DATED (SEE ITEM 11)
10A. MODIFICATION OF CONTRACT/ORDER NUMBER
10B. DATED (SEE ITEM 13)
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended. is not extended.
12. ACCOUNTING AND APPROPRIATION DATA (If required) copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NUMBER AS DESCRIBED IN ITEM 14.
CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER
NUMBER IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15C. DATE SIGNED
15A. NAME AND TITLE OF SIGNER (Type or print)
16C. DATE SIGNED
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
PAGE OF PAGES
6. ISSUED BY CODE
8. NAME AND ADDRESS OF CONTRACTOR (Number, street, county, State and ZIP Code) (X)
CODE
15B. CONTRACTOR/OFFEROR
(Signature of person authorized to sign)
16B. UNITED STATES OF AMERICA
(Signature of Contracting Officer)
Previous edition unusable
3PQCP
See attached.
3PQCP
General Services Administration 100 S Independence Mall West Philadelphia, PA 19106
General Services Administration 100 S Independence Mall West Philadelphia, PA 19106
GS-03-P-17-AZ-C-0014
1 13
01/08/2018
05/26/2017
Amendment 0015 Solicitation GS-03-P-17-AZ-C-0014
Block 14 continuation:
a) This amendment hereby:
1. issues clarifications to the government’s requirement, as attached to this amendment;
2. incorporates L102, L103, L104, and A400, as attached to this amendment.
3. incorporates the Proposal Form, dated January 8, 2018, as attached to this amendment in
Excel format;
i) the burden of accuracy with regard to formulas shall be on the offeror.
4. incorporates a staffing plan format, as attached to this amendment in Excel format, to be completed by the offeror and submitted with revised proposals;
i) the burden of accuracy with regard to formulas shall be on the offeror;
ii) offerors shall coordinate the staffing plan format with proposal form and management approach;
5. incorporates a revised SF1442 for utilization for the revised proposal submissions, as attached to this amendment;
6. removes the Proposal Form, issued under Amendment 0015;
7. removes the SF1442, issued under Amendment 0015;
8. removes L102, L103, L104, and A400, issued under Amendment 0015;
9. increases the page limitation for the Management Approach by 5 pages.
b) Offerors shall note that the cutoff for questions has passed and no additional questions will be responded to by the government.
c) Offerors within the Competitive Range are asked to submit a revised proposal based on these documents, as well areas from discussions, due no later than January 17, 2018 at 12:00 PM
EST.
1. Offerors are requested to specifically highlight any changes made within the technical proposal, if applicable. Offerors are cautioned that the government will only review items that have been highlighted, indicating a change to the technical proposal;
2. Offerors shall submit one (1) original and six (6) copies of their revised technical (if applicable) and price proposals. The proposals are to be submitted unbound and secured with a binder clip. The package shall also include a CD or thumb drive of the proposals.
Amendment 0015 Solicitation GS-03-P-17-AZ-C-0014
d) Revised proposals shall be sent to Nadya L. Popil, Contracting Officer, at 100 S.
Independence Mall West, Philadelphia, PA 19106.
1. Offers sent by commercial package delivery and hand delivery shall be deemed received as of the date and time of delivery to the office designated for receipt of offers;
2. Offers sent by United States Mail shall be deemed timely if delivered to the address of the office designated for receipt of offers on or before the date established for receipt of offers.
e) All other solicitation provisions shall remain unchanged.
Clarification Drawing/Spec Reference Drawing/Spec Reference 2 Submitted Question Government Response
1 Specification 084400
Please confirm that standard commercial warranties are to be provided in lieu of the specified 20 year warranty for curtainwall systems and glazing as shown in specification 084400.
The listed manufacturer’s warranties are the values that are typically specified for components (including 20 years for silicone sealant and 20 years for metal finishes) and would not expect the glazing contractors to take exception.
2 A-204 Detail 31 Please clarify in the detail where Louver 2A (with full blank-off) ends and where Louver Type 2B on top of it begins.
Detail 31 on A204 calls for LVR-2A and LVR-2B. Assume 600sf of louver sqft to be active (not requiring any blankoff).
Top of LVR-2A extends 1'-8 1/2" above Level-R1.
3 12/A312
Detail 12/A312 calls out AVB-1 behind INS-3 for the foundation at the north, west, and east podium window sills. Please confirm that along these sides of the podium, AVB-1 is to be installed at window sill foundation locations only, and not the entire length of the podium wall.
Detail 12/A312 calls out AVB-1 behind INS-3 for the foundation at the north, west, and east podium window sills. The insulation should be called out as INS-5, foil-faced insulation. AVB-1 is not required here.
4 20/A305, 10/A306
Please confirm that the entire length of the dotted lines starting at the superfins represent AVB-1. Refer to details 20/A305 and 10/A306. If yes, please provide the height of the building to which AVB-1 runs.
Assuming the question is about annotations on detail 10 (not 20) on sheet A305, AVB-1 (on sheathing, on cold-form framing) is only on the wall located at the slab-edge at the open-end (in plan) of the precast "superfin". On detail 10/A305, that is the north slab-edge. At non-superfin precast, along the west-elevation, the dotted line represents INS-5, foil-faced insulation.
On detail 20/A306, the same. AVB-1 is only at open-end (in plan) of precast "super-fin"; the south slab-edge.
Assume AVB-1 will run to 1'-8 1/2" above Level-R1.
5 41/A304, 42/A304
Details 41 and 42 on drawing A304 do not call out AVB behind the GRFC on the west podium. Confirm whether or not AVB is to be installed behind the GFRC of the west and east podiums, and if so what type of
AVB.
Insulation shown in detail 41 and 42 on drawing A304 should be tagged INS-3. AVB-1 should also be tagged. It is behind INS-3, applied over sheathing and MBP-1 (where indicated,) on cold-form metal framing. This is typical behind the GFRC-2 and MP- 1B.
6 Responsibility Matrix Specification 280000
The responsibility matrix in Specifications Appendix A states that the PLC detention locking system is to be furnished and installed by the CMc. However Specification Section 280000 says that the PLC detention monitoring and control system is to be provided by the GSA Detention Controls Contractor.
Please confirm that this system is to be provided by the GSA Detention Controls Contractor.
PLC detention control locking system should be provided by the CMc.
7 Responsibility Matrix Specification 280000
Specification section 280000 states that the GSA Security Contractor is responsible for all security system devices. The responsibility matrix in Specifications Appendix A states the the X-ray screening, magnetometer, and lobby turnstiles are to be provided by the CMc. Please clarify if the CMc is to provide the magnetometer, turnstiles, and x-ray systems. If so, please provide specifications for this equipment.
Lobby turnstiles to be provided by the CMc. X-ray machine and magnetometer procurement need to be verified with the USMS.
8 ES201
Drawing ES201 is labeled as work that is NIC to be performed by PPL. However, several of the notes on the drawings call for work to be done by the Electrical Contractor. Please clarify if the work labeled ‘by electrical contractor’ on this drawing is to be included in the CMc scope of work.
The work labeled “by electrical contractor” on ES201 is not required to be performed by the electrical contractor in-so-far as it relates to the scope of work documented on ES201. The entire drawing is issued for information related to perimeter service relocations only.
9 E051
Drawing E051 says to refer to the landscape drawings for site lighting, however there is no site lighting plan in the landscape drawings. Please provide the site lighting plan.
Refer to updated sheets L102, L103, L104 for inclusion of Site Lighting (sheets issued on December 18, 2018 are replaced with sheets issued on January 8, 2018). See additional information included in the original 12/13/2017 submission: Lighting Fixture Cuts in Vol. 2B Specifications immediately following section 26
56 00 SITE LIGHTING.
10 Responsibility Matrix Amendment 11 RFI Responses
Amendment 11 RFI response number 93 states that “structured cabling is not a requirement under this project”. However, the Responsibility Matrix states that the CMc is to furnish and install the Vertical Riser low voltage IT cabling. Please clarify if the CMc is to provide the vertical riser cabling.
Refer to Responsibility Matrix.
11 PBS-P100
Chapter 7 of the PBS-P100 calls for atrium smoke control systems to be installed per IBC requirements.
Please confirm if atrium smoke control needs to be provided in the Level 1 lobby space.
PBS P-100 section 7.11.4 requires that “Atriums must be designed in accordance with the requirements in the IBC.”
The lobby space is not an “atrium,” it is a “two-story opening” that complies with IBC section 712.1.9. Smoke control is not required by IBC section 712.1.9.
12 A400 Provide the following Partition Types which are shown on the drawings but are not detailed in the Partition Schedule: B10, B20, C20, E26, E30, E36.
Refer to updated sheet A400 to include partition types; B10, B20, C20, E26, E30, E36, and F00* (sheets issued on December 18, 2018 are replaced with sheets issued on January 8, 2018).
13 G006 Provide wall finish SWM-1 which is shown on the drawings but is not noted in the Interior Material Index.
SWM-1 was unintentionally omitted from the Interior Materials Index. Refer to 20/A-495 for additional information. This is a secure wire mesh for the holding cells. Description will be added to the Material Index in future submissions.
14 A410
Finish schedule for rooms P1.04 and P1.05 calls out for Terrazzo flooring and PMP-1 base and wall finishes. This appears to be in error. Please verity what finishes are required in these rooms.
The Finish Schedule for rooms P1.04 and P1.05 is in error. The following updates apply to both rooms. Floor: FAF-3 | Base: RB- 1 | Ceiling: - | Wall: PT-1.1/PT-1.3
15 G006 Provide the reveal layout and details for wall finish PT- 1.1.
Wall reveal locations and detail to be developed. Assume 5/8" depth and 1/2" width at reveals.
16 A411 A452 Finish schedule for rooms 01.01, 01.02, and 01.03 refer to A-452 for details, but sheet A-452 is for the Bankruptcy courtroom. Please provide details.
Finish schedule for rooms 01.01, 01.02, and 01.03 refer to A-452 for details. Note has been changed to 'SEE A420' for correct interior elevations.
17 Amendment 11 RFI Response #117
S001, 210548, 220548, 230548
RFI #117 in Amendment 11 asked whether seismic restraint was required for fire suppression, plumbing, and HVAC, as the project is seismic design category A.
The response to this RFI stated that "seismic restraints are not required at this time for plumbing and fire protection piping." Please confirm if seismic restraint is to be included for HVAC.
Seismic restraint is not required for HVAC.
18 P-111
The Level 8 plumbing plan on P-111 has a note to provide pipe lagging for all domestic water, reclaimed water, sanitary, and storm piping. Previously, this keynote was included only on the Level 10 plumbing plan. Please confirm if pipe lagging is only to be provided where indicated on the Level 8 plumbing plan. If not, please provide additional locations where pipe lagging is required.
Where indicated by Note 1 – for this floor the courtroom areas - Note 1 requires pipe lagging in the Courtroom for defined piping systems the run within the courtroom.
19 U.S. Courts Design Guide
Chapter 15 of the U.S. Courts Design Guide calls for a handicapped-accessible emergency shower with floor drain and polyethylene holiding tanks and a handicapped-accessible wash sink in mail rooms. This is not shown in the mailroom on Level GF plumbing plan P-102. Please confirm if the emergency shower and wash sink are to be provided.
The Mail Room has not yet been developed but shall comply with all requirements listed in the the US Courts Design Guide.
20 A104 A411 Finish Schedule A411 calls out PL-1 in room 01.C07 Vending, but nothing is shown on the floor plans.
Please confirm there is no millwork in this room.
Correct, there is NO PL-1 in room 01.C07 Vending.
21 A104 A430, A411
Finish Schedule A411 calls out WD-1 in room 01.C05 Jury Assembly. Elevations on A430 appear to show just PMP-1 panels. Please confirm there are no WD-1 wall panels in this room.
Correct, there is NO WD-1 in room 01.C05 Jury Assembly.
22 A104 A411, A431 Finish Schedule A411 calls out WV-1 in room 01.E01 Hearing. Elevations on A431 show AWP-2 paneling.
Please confirm there is no WV-1 paneling in this room.
Drawing 12/A431 calls for “WV-1” for the spectator rail in room E01.E01 Hearing.
23 A106 A411, A431 Finish Schedule A411 calls out WV-1 in 02.A09 Hearing, but none is shown on the elevations on A431.
Please confirm there is no WV-1 in this room.
Correct, there is no WV-1 in room 02.A09 Hearing.
24 A106 A411, A422 Finish Schedule A411 calls out AWP-2 in 02.01 Elev.
Lobby, but the elevations show PMP-1, with no AWP-
2. Please confirm there is no AWP-2 in this lobby.
Correct, there is NO AWP-2 in 02.01 Elev. Lobby.
25 Specification 012400 3.1-B
Please clarify the award date of Option 2. The proposal form identifies award date as July 30, 2018.
Spec Section 012400-3.1-B identifies award date as October 30, 2018.
Option 2 award date is July 30, 2018.
24 Proposal Form Option 3 Does GSA have ability to award only Option 3A portion of Option 3?
Yes, GSA has ability to only award only Option 3A. Refer to proposal form dated 1.8.18.
HARDSCAPE LEGEND
LAWN
GROUND COVER PLANTINGS
PRECAST MODULAR CONCRETE PAVING,
CONCRETE SIDEWALK
PLANTED BIOFILTRATION AREA
ASPHALT PARKING AREA
RE. L501/1, HANOVER PLANKSTONE 27
8"X 231
2 "X 4"
GRASSCRETE SURFACE
SOFTSCAPE LEGEND
GRASSCRETE SURFACE
'-7
'-9
WATER COLLECTION AND TREATMENT PLANTING
AREA, CONNECTED TO UNDERGROUND
COLLECTION TANK, REFER TO ENG. DWG.
ASPHALT PARKING AREA
NATIVE FREEDOM
LAWN
HARRIS ST.
N 7T
H
ST
W
AL
LA
CE
S T.
TRANSFORMERS
PADS
RETAIN WALLACE ST.
EXISTING CURBS IN GOOD
CONDITIONS
RETAIN N7TH ST.
EXISTING CURBS IN
GOOD CONDITIONS
'-0
A
D
A
V
N
A
N
2'-DEEP
STORMWATER
RETENTION
TRENCH
IMPASSE II SECURITY
FENCING
RETAINING WALL
PAVED AREA
FOR GENERATOR
CONCRETE BENCH,
RE. L301/2
CO
NC
RE
TE
B
EN
CH
'-8
SB-2
SECURITY VEHICLE
ROLL GATE
CONCRETE
STAIRCASE
341 +
+ 344
+ 340.5
+ 338
+ 340
+ 337
+ 336
+ 340
+ 340.5
+ 340.1
340.5 +
340.5 +
341 +
340.9 +
+ 340.5
+ 340.5
+ 339
+ 336
+ 338
+ 340
+ 337
+ 339
+ 336
+ 335
+ 342
341 +
7'-0"
76'-8"
5'-0"
IN
FI
LT
RA
TI
ON
T
RE
NC
H
3,773 SQFT
RAIN
GARDEN
BACK SWALE
BA
CK
S W
AL
E
BA
CK
S W
AL
E
BA
CK
S W
AL
E
BA
CK
S W
AL
E
23,167 SQFT
COURTHOUSE
PARK
CONCRETE PATH
CONCRETE PATH
CO
NC
RE
TE
P
AT
H
CO
NC
RE
TE
P
AT
H
CO
NC
RE
TE
P
AT
H
CONCRETE PATH
1,908 SQFT
RAIN
GARDEN
36 PARKNIG SPOTS
PARKING
LOT
667 SQFT
RAIN
GARDEN
'-0
'-1
'-9
'-1
2'-DEEP
STORMWATER
RETENTION
TRENCH
2'-DEEP
STORMWATER
RETENTION
TRENCH
CONCRETE
SIDEWALK
CONCRETE
SIDEWALK
CONCRETE
SIDEWALK
CONCRETE
SIDEWALK
CONCRETE
SIDEWALK
CONCRETE
SIDEWALK
CONCRETE
SIDEWALK
CO
NC
RE
TE
B
EN
CH
SB-3
SECURITY PERSON SWING
GATE. OPTION SCOPE ONLY,
REFER TO VOL. 3
SB-1
SECURITY FENCE OPTION SCOPE
ONLY, REFER TO VOL. 3
SB-1
SECURITY FENCE
OPTION SCOPE ONLY,
REFER TO VOL. 3
SB-1
SECURITY FENCE
OPTION SCOPE ONLY,
REFER TO VOL. 3
SB-1
SECURITY FENCE
OPTION SCOPE ONLY,
REFER TO VOL. 3
SB-2
SECURITY VEHICLE
ROLL GATE
RETAIN N7TH ST.
EXISTING CURBS IN
GOOD CONDITIONS
342 +
L1
L1
L1
L1
L1
L1
L1
L1 L1
L1
L7(4)
E1
E1
E1
E1
E2
E2
L2
L2
L2
L2
L2
L2
'-7
'-9
WATER COLLECTION AND TREATMENT PLANTING
AREA, CONNECTED TO UNDERGROUND
COLLECTION TANK, REFER TO ENG. DWG.
ASPHALT PARKING AREA
NATIVE FREEDOM
LAWN
HARRIS ST.
N 7T
H
ST
W
AL
LA
CE
S T.
TRANSFORMERS
PADS
RETAIN WALLACE ST.
EXISTING CURBS IN GOOD
CONDITIONS
RETAIN N7TH ST.
EXISTING CURBS IN
GOOD CONDITIONS
'-0
A
N
A
N
2'-DEEP
STORMWATER
RETENTION
TRENCH
IMPASSE II SECURITY
FENCING
RETAINING WALL
PAVED AREA
FOR GENERATOR
CONCRETE BENCH,
RE. L301/2
CO
NC
RE
TE
B
EN
CH
'-8
SB-2
SECURITY VEHICLE
ROLL GATE
CONCRETE
STAIRCASE
341 +
+ 344
+ 340.5
+ 338
+ 340
+ 337
+ 336
+ 340
+ 340.5
+ 340.1
340.5 +
340.5 +
341 +
340.9 +
+ 340.5
+ 340.5
+ 339
+ 336
+ 338
+ 340
+ 337
+ 339
+ 336
+ 335
+ 342
341 +
7'-0"
76'-8"
5'-0"
IN
FI
LT
RA
TI
ON
T
RE
NC
H
3,773 SQFT
RAIN
GARDEN
BACK SWALE
BA
CK
S W
AL
E
BA
CK
S W
AL
E
BA
CK
S W
AL
E
BA
CK
S W
AL
E
23,167 SQFT
COURTHOUSE
PARK
CONCRETE PATH
CONCRETE PATH
CO
NC
RE
TE
P
AT
H
CO
NC
RE
TE
P
AT
H
CO
NC
RE
TE
P
AT
H
CONCRETE PATH
1,908 SQFT
RAIN
GARDEN
36 PARKNIG SPOTS
PARKING
LOT
667 SQFT
RAIN
GARDEN
'-0
'-1
'-9
'-1
2'-DEEP
STORMWATER
RETENTION
TRENCH
2'-DEEP
STORMWATER
RETENTION
TRENCH
CONCRETE
SIDEWALK
CONCRETE
SIDEWALK
CONCRETE
SIDEWALK
CONCRETE
SIDEWALK
CONCRETE
SIDEWALK
CONCRETE
SIDEWALK
CONCRETE
SIDEWALK
CO
NC
RE
TE
B
EN
CH
SB-3
SECURITY PERSON SWING
GATE. OPTION SCOPE ONLY,
REFER TO VOL. 3
SB-1
SECURITY FENCE OPTION SCOPE
ONLY, REFER TO VOL. 3
SB-1
SECURITY FENCE
OPTION SCOPE ONLY,
REFER TO VOL. 3
SB-1
SECURITY FENCE
OPTION SCOPE ONLY,
REFER TO VOL. 3
SB-1
SECURITY FENCE
OPTION SCOPE ONLY,
REFER TO VOL. 3
SB-2
SECURITY VEHICLE
ROLL GATE
RETAIN N7TH ST.
EXISTING CURBS IN
GOOD CONDITIONS
342 +
L1
L1
L1
L1
L1
L1
L1
L1 L1
L1
L7(4)
E1
E1
E1
E1
E2
E2
L2
L2
L2
L2
L2
L2
1+2
L-202
L-202
Harrisburg Federal Courthouse
GS-03-P-17-AZ-C-0008
PA0784ZZ
Harrisburg Federal Courthouse
8' 16'
1/8"=1'-0"
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY - DO NOT REMOVE THIS NOTICE - PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
U.S. General Services Administration
Mid-Atlantic Region
Public Buildings Service
The DOW Building
100 South Independance Mall West
Philadelphia, PA 19106-2320
Arch E (36 X 48)
Zimmerman, G
Ennead Architects, LLP
Sarko, M
320 West 13th Street
New York NY
MC,SH
JGC
100% DESIGN DEVELOPMENT - 12/13/2017
HARRIS ST.
REILY ST.
N 7T
H
ST
N 6 T
H
ST
W
AL
LA
CE
S T.
BOYD ST.
GROUND FLOOR LAYOUT AND
GRADING PLAN
L-102
GROUND FLOOR LAYOUT AND GRADING PLAN
SCALE: 1/8" = 1'
07/28/2017SOUTH SIDEWALK AND
SLOPE MODIFICATION
12/13/2017100% DD Submission
AutoCAD SHX Text
SU-40
AutoCAD SHX Text
AASHTO 2011 (US)
AutoCAD SHX Text
SU-40
AutoCAD SHX Text
AASHTO 2011 (US)
AutoCAD SHX Text
SU-40
AutoCAD SHX Text
AASHTO 2011 (US)
AutoCAD SHX Text
SU-40
AutoCAD SHX Text
AASHTO 2011 (US)
UPUP
3' x 1'-6" DEPHT BACK SWALE ZONE
80% SAND AND SOIL
PRECAST CONC. CURVED
SEATING / RETAINING WALL, RE.
L401/3
CONCRETE BENCH
CUSTOM CONCRETE
PLANTER
REILY ST.
BOYD ST.BIKE RACKS
CAPACITY 48 BICYCLES
BACK SWALE
TRANSFORMERS
PADS
5'-4" x 65'-8" AIR EXHAUST
GRATING FROM MECHANICAL
ROOM
RAIN GARDEN
BOLLARDS AT 5'
SPACING ON CENTER
T.O.W TO BE MAX 30"
ABOVE TOPOGRAPHY
S.STEEL
GUARDRAIL
WATER VAULT UNDER,
REFER TO ENG.
DRAWINGS.
CONCRETE
STAIRCASE
7'-0"
5'-0"
CONC.
BENCH
4,480 SQFT
GREEN ROOF
GARDEN
18,579 SQFT
TOPO LAWN
8,674 SQFT
ENTRY PLAZA
3,947 SQFT
TERRACED
GARDEN
BACK SW
ALE
BACK SWALE BACK SWALEBACK SWALE
BACK SWALE
CONCRETE BENCH
CONCRETE BENCH
CONCRETE BENCH
CONCRETE BENCH
CONCRETE BENCH
CONCRETE BENCH
389 SQFT
RAIN
GARDEN
1,450 SQFT
RAIN
GARDEN
7,604 SQFT
HEMLOCK
TERRACE
2%
RAM
P
RETAINING BENCH W
ALL
RETAINING W
ALL
RETAINING BENCH W
ALL
3,123 SQFT
TOPO GARDEN
AT GRADE
T.O.W TO BE MAX 30"
ABOVE TOPOGRAPHY
CONCRETE
SIDEWALK
CONCRETE
SIDEWALK
CONCRETE
SIDEWALK
CONCRETE
SIDEWALK
CONCRETE
SIDEWALK
CONCRETE
SIDEWALK
CONCRETE
SIDEWALK
CONCRETE BENCH
CURVED CONCRETE WALL
+ T.O.W 359'-8"
CURVED CONCRETE WALL
CUSTOM CONCRETE
STAIRS
695 SQFT
CONCRETE
PLANTER
L1L1
L1
L1
L1
L1
L1
L1
L1 L1
L1
L1
L8
L8
L8
L8
L8
L8
L5
L4
L4
L4
L4
L4
L4
L4
L4
L4
L7(4)
L1
L1
L1
UPUP
3' x 1'-6" DEPHT BACK SWALE ZONE
80% SAND AND SOIL
PRECAST CONC. CURVED
SEATING / RETAINING WALL, RE.
L401/3
CONCRETE BENCH
CUSTOM CONCRETE
PLANTER
REILY ST.
BOYD ST.BIKE RACKS
CAPACITY 48 BICYCLES
BACK SWALE
TRANSFORMERS
PADS
5'-4" x 65'-8" AIR EXHAUST
GRATING FROM MECHANICAL
ROOM
RAIN GARDEN
BOLLARDS AT 5'
SPACING ON CENTER
T.O.W TO BE MAX 30"
ABOVE TOPOGRAPHY
S.STEEL
GUARDRAIL
WATER VAULT UNDER,
REFER TO ENG.
DRAWINGS.
CONCRETE
STAIRCASE
7'-0"
5'-0"
CONC.
BENCH
4,480 SQFT
GREEN ROOF
GARDEN
18,579 SQFT
TOPO LAWN
8,674 SQFT
ENTRY PLAZA
3,947 SQFT
TERRACED
GARDEN
BACK SW
ALE
BACK SWALE BACK SWALEBACK SWALE
BACK SWALE
CONCRETE BENCH
CONCRETE BENCH
CONCRETE BENCH
CONCRETE BENCH
CONCRETE BENCH
CONCRETE BENCH
389 SQFT
RAIN
GARDEN
1,450 SQFT
RAIN
GARDEN
7,604 SQFT
HEMLOCK
TERRACE
2%
RAM
P
RETAINING BENCH W
ALL
RETAINING W
ALL
RETAINING BENCH W
ALL
3,123 SQFT
TOPO GARDEN
AT GRADE
T.O.W TO BE MAX 30"
ABOVE TOPOGRAPHY
CONCRETE
SIDEWALK
CONCRETE
SIDEWALK
CONCRETE
SIDEWALK
CONCRETE
SIDEWALK
CONCRETE
SIDEWALK
CONCRETE
SIDEWALK
CONCRETE
SIDEWALK
CONCRETE BENCH
CURVED CONCRETE WALL
+ T.O.W 359'-8"
CURVED CONCRETE WALL
CUSTOM CONCRETE
STAIRS
695 SQFT
CONCRETE
PLANTER
L1L1
L1
L1
L1
L1
L1
L1
L1 L1
L1
L1
L8
L8
L8
L8
L8
L8
L5
L4
L4
L4
L4
L4
L4
L4
L4
L4
L7(4)
L1
L1
L1
L
L
L
L-204
HARDSCAPE LEGEND
LAWN
GROUND COVER PLANTINGS
PRECAST MODULAR CONCRETE PAVING,
CONCRETE SIDEWALK
PLANTED BIOFILTRATION AREA
ASPHALT PARKING AREA
RE. L501/1, HANOVER PLANKSTONE 27
8"X 231
2 "X 4"
GRASSCRETE SURFACE
SOFTSCAPE LEGEND
GRASSCRETE SURFACE
Harrisburg Federal Courthouse
GS-03-P-17-AZ-C-0008
PA0784ZZ
Harrisburg Federal Courthouse
8' 16'
1/8"=1'-0"
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY - DO NOT REMOVE THIS NOTICE - PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
U.S. General Services Administration
Mid-Atlantic Region
Public Buildings Service
The DOW Building
100 South Independance Mall West
Philadelphia, PA 19106-2320
Arch E (36 X 48)
Zimmerman, G
Ennead Architects, LLP
Sarko, M
320 West 13th Street
New York NY
MC,SH
JGC
100% DESIGN DEVELOPMENT - 12/13/2017
HARRIS ST.
REILY ST.
N 7T
H
ST
N 6 T
H
ST
W
AL
LA
CE
S T.
BOYD ST.
L01 WEST LAYOUT AND
GRADING PLAN
L-103
L01 WEST LAYOUT AND GRADING PLAN
SCALE: 1/8" = 1'
07/28/2017SOUTH SIDEWALK AND
SLOPE MODIFICATION
12/13/2017100% DD Submission
UPUPUPUPUPUP
CLERESTORY ABOVE
'-7
CONCRETE
SIDEWALK
CONCRETE BENCH,
RE. L301/2
TRANSFORMERS
PADS
RETAIN REILY ST.
EXISTING CURBS IN
GOOD CONDITIONS
RETAIN N7TH ST.
EXISTING CURBS IN
GOOD CONDITIONS
INFILTRATION TRENCH METAL
EDGE, REFER TO SECTION
RETAIN EXTG TREES
ON SIDEWALK
RETAINING WALL
'-8
CONCRETE
STAIRCASE
341 +
+ 348
+ 346
+ 344
+ 350
341 +
340.9 +
+ 342
7'-0"
76'-8"
5'-0"
BACK SWALE
INFILTRATION TRENCH
INFIL
TR
ATIO
N TR
EN
CH
IN
FI
LT
RA
TI
ON
T
RE
NC
H
IN
FI
LT
RA
TI
ON
T
RE
NC
H
CONCRETE BENCH
CONCRETE BENCH
667 SQFT
RAIN
GARDEN
18,579 SQFT
TOPO GARDEN
6,210 SQFT
EAST TOPO
GARDEN
1,419 SQFT
GREEN ROOF
GARDEN
CONCRETE
SIDEWALK
SB-3
SECURITY PERSON SWING
GATE. OPTION SCOPE ONLY,
REFER TO VOL. 3
SB-1
SECURITY FENCE
OPTION SCOPE ONLY,
REFER TO VOL. 3
342 +
L1
L1
L1 L1
L1
L1
L7(4)
L3
L3
L3
L3
E1
E1
E1
E2
UPUPUPUPUPUP
CLERESTORY ABOVE
'-7
CONCRETE
SIDEWALK
CONCRETE BENCH,
RE. L301/2
TRANSFORMERS
PADS
RETAIN REILY ST.
EXISTING CURBS IN
GOOD CONDITIONS
RETAIN N7TH ST.
EXISTING CURBS IN
GOOD CONDITIONS
INFILTRATION TRENCH METAL
EDGE, REFER TO SECTION
RETAIN EXTG TREES
ON SIDEWALK
RETAINING WALL
'-8
CONCRETE
STAIRCASE
341 +
+ 348
+ 346
+ 344
+ 350
341 +
340.9 +
+ 342
7'-0"
76'-8"
5'-0"
BACK SWALE
INFILTRATION TRENCH
INFIL
TR
ATIO
N TR
EN
CH
IN
FI
LT
RA
TI
ON
T
RE
NC
H
IN
FI
LT
RA
TI
ON
T
RE
NC
H
CONCRETE BENCH
CONCRETE BENCH
667 SQFT
RAIN
GARDEN
18,579 SQFT
TOPO GARDEN
6,210 SQFT
EAST TOPO
GARDEN
1,419 SQFT
GREEN ROOF
GARDEN
CONCRETE
SIDEWALK
SB-3
SECURITY PERSON SWING
GATE. OPTION SCOPE ONLY,
REFER TO VOL. 3
SB-1
SECURITY FENCE
OPTION SCOPE ONLY,
REFER TO VOL. 3
342 +
L1
L1
L1 L1
L1
L1
L7(4)
L3
L3
L3
L3
E1
E1
E1
E2
L-202
HARDSCAPE LEGEND
LAWN
GROUND COVER PLANTINGS
PRECAST MODULAR CONCRETE PAVING,
CONCRETE SIDEWALK
PLANTED BIOFILTRATION AREA
ASPHALT PARKING AREA
RE. L501/1, HANOVER PLANKSTONE 27
8"X 231
2 "X 4"
GRASSCRETE SURFACE
SOFTSCAPE LEGEND
GRASSCRETE SURFACE
Harrisburg Federal Courthouse
GS-03-P-17-AZ-C-0008
PA0784ZZ
Harrisburg Federal Courthouse
8' 16'
1/8"=1'-0"
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY - DO NOT REMOVE THIS NOTICE - PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
U.S. General Services Administration
Mid-Atlantic Region
Public Buildings Service
The DOW Building
100 South Independance Mall West
Philadelphia, PA 19106-2320
Arch E (36 X 48)
Zimmerman, G
Ennead Architects, LLP
Sarko, M
320 West 13th Street
New York NY
MC,SH
JGC
100% DESIGN DEVELOPMENT - 12/13/2017
HARRIS ST.
REILY ST.
N 7T
H
ST
N 6 T
H
ST
W
AL
LA
CE
S T.
BOYD ST.
L01 EAST LAYOUT AND
GRADING PLAN
L-104
L01 EAST LAYOUT AND GRADING PLAN
SCALE: 1/8" = 1'
07/28/2017SOUTH SIDEWALK AND
SLOPE MODIFICATION
12/13/2017100% DD Submission
AutoCAD SHX Text
SU-40
AutoCAD SHX Text
AASHTO 2011 (US)
AutoCAD SHX Text
SU-40
AutoCAD SHX Text
AASHTO 2011 (US)
AutoCAD SHX Text
SU-40
AutoCAD SHX Text
AASHTO 2011 (US)
AutoCAD SHX Text
SU-40
AutoCAD SHX Text
AASHTO 2011 (US)
LINE OF CEILING. SEE FINISH SCHEDULE
HORIZONTAL JOINT REINFORCING AT
BOTTOM COURSE, TOP COURSE AND
16" O.C. VERTICALLY
T.O. SLAB
HEAD SEAL. SEE PARTITION DETAILSLINE OF CEILING. SEE FINISH SCHEDULE
ADDITIONAL LAYERS OF GWB
WHERE SCHEDULED
SOUND ATTENUATION BLANKET
WHERE SCHEDULED
EDGE TRIM TYPICAL WHERE VISIBLE
UNDERSIDE OF STRUCTURE,SEE NOTE 2
SEE STRUCTURAL DRAWINGS FOR BOND
BEAM AND REINFORCING REQUIREMENTS
T.O. SLAB
5/8" GYPSUM WALL BOARD (TYP.)
METAL STUDS (SEE SCHEDULE BELOW)
LINE OF CEILING. SEE FINISH SCHEDULE
EDGE TRIM TYPICAL WHERE VISIBLE
ADDITIONAL LAYER OF GWB
WHERE SCHEDULED
SOUND ATTENUATION BLANKET
WHERE SCHEDULED
T.O. SLAB
5/8" GYPSUM WALL BOARD (TYP.)
METAL STUDS (SEE SCHEDULE BELOW)
2 1/2" METAL STUDS @ 4'-0" O.C. VERTICAL
LINE OF CEILING. SEE FINISH SCHEDULE
EDGE TRIM TYPICAL WHERE VISIBLE
SOUND ATTENUATION BLANKET
WHERE SCHEDULED
T.O. SLAB
5/8" GYPSUM WALL BOARD (TYP.)
METAL C-H STUD U.O.N (SEE SCHEDULE
BELOW)
1" THICK LINER BOARD
5/8"
5/8"
5/8"
5/8"
SHIM
SPACE
VARIES 5/8"
VARIES 5/8"
LINE OF CEILING. SEE FINISH SCHEDULE
UNDERSIDE OF STRUCTURE, SEE NOTE 2
EDGE TRIM TYPICAL WHERE VISIBLE
ADDITIONAL LAYER OF GWB
WHERE SCHEDULED
SOUND ATTENUATION
BLANKET
WHERE SCHEDULED
T.O. SLAB
5/8" GYPSUM WALL BOARD (TYP.)
METAL STUDS (SEE SCHEDULE BELOW) HORIZONTAL
BRIDGING AT 48" O.C.
SHIM
SPACE
UNDERSIDE OF STRUCTURE
EDGE TRIM TYPICAL WHERE VISIBLE
ADDITIONAL LAYER OF
GWB
WHERE SCHEDULED
T.O. SLAB
5/8" GYPSUM WALL BOARD (TYP.)
SHIM SPACE. SIZE AS REQ'D TO
ENSURE
PLUMBNESS OF GWB.
METAL CHANNELS (SEE SCHEDULE BELOW)
5/8"VARIES
PERIMETER APPLICATION OF
CONT. BEAD OF SEALANT.
CONT. FIRE RETARDANT BLOCKING.
CONT. FIRE RETARDANT BLOCKING.
PERIMETER APPLICATION OF
CONT. BEAD OF SEALANT.
L-3"x3 1/4‚", 6" LONG, ALTERNATE AT 4'O.C. EACH SIDE
5/8"
F
APPLIED FURRING
SCALE: 1 1/2" = 1'-0"
FURRING WALL
E
SCALE: 1 1/2" = 1'-0"
SHAFT WALL
D
SCALE: 1 1/2" = 1'-0"
CHASE WALL
C
SCALE: 1 1/2" = 1'-0"
STUD WALL
B
SCALE: 1 1/2" = 1'-0"
CMU WALL
A
SCALE: 1 1/2" = 1'-0"
HOLLOW CMU UNITS FOR EACH
THICKNESS AND RATING.
SEE SCHEDULE BELOW
FILLED CORES AT REINFORCING AND
WHERE SCHEDULED BELOW
WIDTH
MAX.
HEIGHT
MIN.
GAUGE
FIRE
RATING REMARKSINSUL.
STC
RATING
NOMINAL
SIZE
ACTUAL
SIZE
6"
5 5/8"
5 5/8"
18'-0"
N/A N/A N/A
NONE NON-LOAD BEARING
WIDTH
MAX.
HEIGHT
MIN.
GAUGE /
MIL.
FIRE
RATING REMARKSINSUL.
STC
RATING
STUD
SIZE
SPACING
WIDTH
MAX.
HEIGHT
MIN.
GAUGE /
MIL.
FIRE
RATING REMARKSINSUL.
STC
RATING
STUD
SIZE
STUD
SIZE
SPACINGSPACING
16" O.C.
20/33
NONE
N/A
16'-5"
16" O.C.
20/33 47
16" O.C.
5 1/2"
20/33 50
16" O.C.
6 1/8"
20/33 53
N/A 16" O.C.
20/33
NONE
N/A47
16" O.C.
20/33
1 HR
16" O.C.
20/33 53
6" 18'-0"
N/A N/A U906
NONE NON-LOAD BEARING2 HOUR
MEA/BSA
16" O.C.16"O.C.
VARIES-24"MAX
16'-5"
20/33 57
16" O.C.16"O.C.
VARIES-24"MAX
24'-6" --
NONE
N/A
3 1/2"
16'-5" 3 1/2"
16'-5" 3 1/2"
1 HOUR
1 HR
OSU
T3240
17'-3" 3 1/2" 2 HOUR
6"
6"
7 7/8"
6"
8 1/2"
24'-6" 5 1/2"
24'-6"
24'-6"
5 1/2"
5 1/2"
OSU
T3240
2 HOUR
2 HOUR
UL
U420
UL
U420
2 HOUR
5720/33
WIDTH
MAX.
HEIGHT
FIRE
RATING REMARKSINSUL.
STC
RATING
STUD
SIZE
SPACING
24" O.C.
2 1/2"
20/33
2 1/2 "
UL
U438
ADDITIONAL LAYERS OF GWB
WHERE SCHEDULED
3 3/4"
2 HOUR
24" O.C.
4 5/8"
20/33 52
1 HOUR
UL
U469
24" O.C.
5 1/4"
20/33
2 HOUR
UL
U467
24" O.C.
20/33 UL
U438 7 1/4"
2 HOUR
4" 3 1/2"
4"
3 1/2"
5 1/2"6"
WIDTH
MAX.
HEIGHT
FIRE
RATING REMARKSINSUL.
STC
RATING
STUD
SIZE
SPACING
VARIES
N/A 16" O.C.
3 5/8" 16'-3"
20/33
NONE
N/A
NONE
N/A
GWB TO 6" ABOVE
CEILING
VARIES
N/A 16" O.C.
N/A
NONE
N/A
3 1/2" --24'-1"
20/33
6"
WIDTH
MAX.
HEIGHT
MIN.
GAUGE
FIRE
RATING REMARKSINSUL.
STC
RATINGSPACING
LINE OF CEILING. SEE FINISH SCHEDULE
STUD
SIZE
VARIES
N/A 24" O.C.
7/8"
N/A
N/A
N/A
N/A
N/A
TEST
DESIGN
TEST
DESIGN
TEST
DESIGN
TEST
DESIGN
TEST
DESIGN
TEST
DESIGN
MEA/BSAMEA/BSAMEA/BSAMEA/BSAMEA/BSAMEA/BSA
UL
U419
MEA 81-98-M
UL
U419
MEA 81-98-M
UL
U419
MEA 81-98-M
BSA 354-78-SM
BSA 339-81-SM
BSA 354-78-SM
BSA 354-78-SM
BSA 173-77-SM
BSA 173-77-SM
N/A
METAL RUNNER
METAL RUNNER
CONT. BEAD OF SEALANT (1 BEAD
@ EACH LAYER GWB TYPICAL).
METAL RUNNER
METAL RUNNER
CONT. BEAD OF SEALANT (1 BEAD @
EACH LAYER GWB TYPICAL).
METAL RUNNER
METAL RUNNER
CONT. BEAD OF SEALANT (1 BEAD @
EACH LAYER GWB TYPICAL).
15'-3"
17'-6"
18'-2"
25'-1"
**VENT SHAFTS
*ELEV. CORES
**VENT SHAFTS
*ELEV. CORES
**VENT SHAFTS
*ELEV. CORES
**VENT SHAFTS
*ELEV. CORES
**10'-7" *12'-1"
**12'-2" *13'-11"
**12'-7" *14'-5"
**17'-5" *19'-11"
METAL RUNNER FASTENED
SHIM SPACE
METAL RUNNER
BEADS OF SEALANT
(1 BEAD @ EACH LAYER GWB TYPICAL).
TYPE
BASE
PLAN
HEAD
BASE
PLAN
HEAD
BASE
PLAN
HEAD
BASE
PLAN
HEAD
BASE
PLAN
HEAD HEAD
PLAN
BASE
A10
A14
TYPE
B12
B14
B16
B18
B22
B26
B28
TYPE
C14
C24
TYPE
D04
D10
D12
D24
TYPE
E20
E34
TYPE
F00 3 5/8" 3 5/8"
5/8" 5/8"
5/8" 5/8" 6" 6"
4 7/8"
3 5/8" 5/8" 5/8"
4 7/8"
3 5/8" 5/8" 5/8"
5/8"5/8" 3 5/8"
5/8" 5/8" 3 5/8"
5/8" 5/8"
7 1/4"
5/8" 5/8"
5/8" 5/8"
5 5/8"
5 5/8"
GENERAL NOTES
1. SEE PROJECT SPECIFICATIONS FOR PERFORMANCE
CRITERIA FOR ALL STUD AND MASONRY PARTITIONS. LIMITING
HEIGHTS ARE BASED ON L/240, DEFLECTION TYPICAL.
PARTITION WITH APPLIED TILE OR PLASTER FINISHES ARE TO
BE LIMITED TO L/360 DEFLECTION.
2. PROVIDE U.L. 2709 COMPLIANT DYNAMIC HEAD JOINTS AT ALL
RATED PARTITIONS. SEE TYPICAL PARTITION DETAILS. FOR
FIRE RATED AND NON-RATED PARTITION HEAD DETAILS.
3. INSTALL 16 GA STUDS AT ALL LOCATIONS WHERE BACKING
PLATES ARE INDICATED.
4. INSTALL TILE BACKER BOARD IN LIEU OF GYPSUM WALL
BOARD AT LOCATIONS INDICATED TO RECEIVE WALL TILE.
INSTALL TYPE "X" BACKER BOARD AT RATED PARTITIONS.
5. INSTALL WATER RESISTANT GYPSUM WALL BOARD AT
EXTERIOR WALL FURRING AND ALL SURFACES IN TOILET
ROOMS, JANITORS CLOSETS AND SIMILAR WET AREAS NOT
INDICATED TO RECEIVE WALL TILE.
6. INSTALL TYPE "X" FIRE RATED GWB AT ALL FIRE RATED
PARTITIONS.
7. INSTALL "BLUEBOARD" GYPSUM WALL BOARD AT PARTITIONS
INDICATED TO RECEIVE VENEER PLASTER.
8. SEE FINISH SCHEDULE FOR LOCATIONS TO RECEIVE IMPACT
RESISTANT GYPSUM WALL BOARD.
9. STC RATINGS PROVIDE ONLY A GENERAL INDICATION OF
ACOUSTIC PERFORMANCE UNDER LABORATORY TEST
CONDITIONS. CONSTRUCTION DETAILS DESCRIBED IN THE
DRAWINGS AND SPECIFICATIONS DEFINE THE SPECIFIC
REQUIREMENTS FOR THE WORK.
10. EXTRA LAYER OF GYPSUM WALL BOARD AT ASYMMETRICAL
PARTITIONS IS TO BE INSTALLED ON SIDE OF PARTITION WHICH
TYPE KEY IS SHOWN.
11. SEE ACOUSTICAL REPORT FOR REQUIRED STC RATINGS OF
PARTITIONS.
12. SEE LIFE SAFETY DRAWINGS FOR FIRE RATING
REQUIREMENTS OF PARTITIONS.
UNDERSIDE OF STRUCTURE,SEE NOTE 2 UNDERSIDE OF STRUCTURE,SEE NOTE 2 UNDERSIDE OF STRUCTURE,SEE NOTE 2
MIN.
GAUGE /
MIL.
MIN.
GAUGE /
MIL.
(2) 3 1/2"
(2) 5 1/2"
HEAD SEAL, SEE PARTITION DETAILS HEAD SEAL, SEE PARTITION DETAILS HEAD SEAL, SEE PARTITION DETAILS HEAD SEAL, SEE PARTITION DETAILS
5/8"
16" O.C.
20/33 50
16" O.C.
20/33 53
6"
7 7/8"
6"
8 1/2"
24'-6"
24'-6"
5 1/2"
5 1/2"
OSU
T3240
UL
U419
MEA 81-98-M
B25
B27
5/8" 5/8"
5/8" 5/8"
5/8" 5/8"
NONE
NONE
16" O.C.
5 1/2"
20/33 50
16" O.C.
6 1/8"
20/33 53
16'-5" 3 1/2"
OSU
T3240
17'-3" 3 1/2"
UL
U419
MEA 81-98-M
B15
B17
5/8"5/8" 3 5/8"
5/8" 5/8"
3 5/8" NONE
NONE
VARIES 5/8"
VARIES
N/A 16" O.C.
N/A
NONE
N/A
3 1/2" --24'-1"
20/33
6" E36
VARIES 5/8"
VARIES
N/A 16" O.C.
24'-1"
20/33
3 1/2"
N/A
NONE
N/A
GWB TO 6" ABOVE
CEILING6"
E30
VARIES 5/8"
VARIES
N/A 16" O.C.
N/A
NONE
N/A
3 1/2" --24'-1"
20/33
3 5/8" E26
N/A 16" O.C.16"O.C.
6" 6"
VARIES-24"MAX
24'-6"
20/33 52
NONE
N/A
C20
5/8"5/8"
(2) 5 1/2"
N/A
3 5/8"
16" O.C.
4 7/8"
20/33
NONE NONE
N/A
16'-5"
N/A
GWB TO 6" ABOVE
CEILING
B10
5/8"5/8"
N/A 16" O.C.
7 1/4"
20/33
NONE NONE
N/A
6" 24'-6"
N/A
GWB TO 6" ABOVE
CEILING
B20
5/8" 5/8"
5/8"
N/A
N/A
N/A
N/A
N/A
N/A
GWB ONLY
F00*
0 8' 16' 1/8"=1'-0"
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY - DO NOT REMOVE THIS NOTICE - PROPERLY DESTROY DOCUMENTS WHEN NO LONGER NEEDED
U.S. General Services Administration Mid-Atlantic Region Public Buildings Service The DOW Building 100 South Independance Mall West Philadelphia, PA 19106-2320
Arch E (36 X 48)
GR
AP
HI
C
SC
AL
E
CO
NT
RA
CT
AR
CH
ITE
CT
/E
NG
IN
EE
R
BU
ILD
IN
G
PR
OJ
EC
T
DR
AW
IN
G
A/E
CONSTRUCT.
PRIME A/E
PRIME A/E
PROJ. MGR.
SUB A/E
SUB A/E
NAME
ADDRESS
BLDG. NO.
ADD'L FACILITY
ADD'L FAC. NO.
TITLE
DESCRIPTION
SUBMISSION
GSA
PROJ. MGR.
PROJ. NO.
DRAWN BY
CKD BY
FILE NAME
FLOOR NO.
TITLE
NUMBER
ADDRESS
ADDRESS
ADDRESS
DATE CKD
DT. DRAWN
SUB. DATE
STATE
CITY
STREET
ZIP CODE
CITY
STREET
CITY
STREET
STATE
STATE
STATECITY
STREET
Zimmerman, G
DISCIPLINE SHEET TYPE SEQUENCE
CAD FILE INFORMATION
KEY PLAN
Ennead Architects, LLP
Sarko, M
320 West 13th Street New York NY
Architect Court Planning Ricci Greene Associates 158 West 27th Street New York, NY 10001
212.563.9154 tel 212.279.1037 fax www.riccigreene.com
ENNEAD ARCHITECTS, LLP
320 West 13th Street New York, NY 10014-1278
212.807.7171 tel 212.807.5917 fax www.ennead.com
Civil / Geotechnical HVAC, Electrical, & Sustainability R.G. Vanderweil Engineers 274 Summer Street Boston, MA 02210
617.423.7423 tel 617.423.7401 fax
Dawood Engineering 2020 Good Hope Road Enola, PA 17025
717.732.8576 tel
Landscape Architecture Plumbing & Fire Protection Thomas Polise Consulting Engineer PC 133 West 19th Street New York, NY 10011
212.645.1002 tel 212.645.3905 fax
Balmori Associates 584 Broadway, Suite 1201 New York, NY 10012
212.431.9191 tel 212.431.8616 fax
Structure & Blast Protection Life Safety Jensen Hughes 3610 Commerce Drive, Suite 817 Baltimore, MD 21227
410.737.8677 tel
Thornton Tomasetti 40 Wall Street New York, NY 10005
212.367.3000 tel 212.497.2374 fax
Structure - Foundations Lighting SBLD Studio 132 West 36th Street, 10th Fl New York, NY 10018
212.391.4230 tel 212.391.4231 fax
Woods - Peacock Halifax Office Park, Suite 420 5250 Cherokee Avenue Alexandria, VA 22312
703.658.4400 tel
Urban Planning Acoustic & Audio Visual Cerami & Associates 404 5th Avenue New York, NY 10018
212.370.1776 tel
Office of Planning and Architecture 234 Liberty Street Harrisburg, PA 17101
717.230.9660 tel 717.230.9664 fax
N 6th Street & Reilly Street Harrisburg
PA
17102
N
1/ 5/
1:
:4
AM
A400
Harrisburg Federal Courthouse
EPGS03P17AZC0008
WALL TYPES & PARTITION DETAILS
12/13/2017Design Development
GS-03-P-17-AZ-C-0014
GS-03-P-17-AZ-C-0008
PA0784ZZ
Harrisburg Federal Courthouse
A-400.dwg
1 1/2" = 1'-0"10 PARTITION TYPES
REVISION NUMBER REVISION DESCRIPTION REVISION DATE
(See ).
SOLICITATION, OFFER,
AND AWARD
(Construction, Alteration, or Repair) IMPORTANT - The "offer" section on the reverse must be fully completed by offeror.
9. FOR INFORMATION
CALL:
NOTE: In sealed bid solicitations "offer" and "offeror" mean "bid and "bidder".
SOLICITATION
1. SOLICITATION NUMBER
5. REQUISITION/PURCHASE REQUEST NUMBER
CODE
6. PROJECT NUMBER
8. ADDRESS OFFER TO
4. CONTRACT NUMBER
7. ISSUED BY
10. THE GOVERNMENT REQUIRES PERFORMANCE OF THE WORK DESCRIBED IN THESE DOCUMENTS (Title, identifying number, date)
11. The contractor shall begin performance within
12a. THE CONTRACTOR MUST FURNISH ANY REQUIRED PERFORMANCE AND PAYMENT BONDS?
(If "YES", indicate within how many calendar days after award in Item 12b.)
13. ADDITIONAL SOLICITATION REQUIREMENTS:
a. Sealed offers in original and
b. An offer guarantee
c. All offers are subject to the (1) work requirements, and (2) other provisions and clauses incorporated in the solicitation in full text or by reference.
d. Offers providing less than
STANDARD FORM 1442 (REV. 8/2014)
Prescribed by GSA - FAR (48 CFR) 53.236-1(d) calendar days for Government acceptance after the date offers are due will not be considered and will be rejected.
is, is not required.
local time containing offers shall be marked to show the offeror's name and address, the solicitation number, and the date and time offers are due.
(date). If this is a sealed bid solicitation, offers will be publicly opened at that time. Sealed envelopes copies to perform the work required are due at the place specified in Item 8 by (hour) award, YES NO notice to proceed. This performance period is mandatory negotiable.
calendar days and complete it within calendar days after receiving
a. NAME b. TELEPHONE NUMBER (Include area code) (NO COLLECT CALLS)
12b. CALENDAR DAYS
2. TYPE OF SOLICITATION
SEALED BID (IFB)
NEGOTIATED (RFP)
3. DATE ISSUED PAGE OF PAGES
GS-03-P-17-AZ-C-0014
GSA CONTRACTS OPS BRANCH - PA NJ & DE SECTION
100 S. INDEPENDENCE MALL WEST
PHILADELPHIA, PA 19106
Construction Manager as Contractor (CMc) Solicitation for the New United States Courthouse in Harrisburg, Pennsylvania
3PQCP
GSA CONTRACTS OPS BRANCH - PA NJ & DE SECTION
100 S. INDEPENDENCE MALL WEST
PHILADELPHIA, PA 19106
3PQCP
Nadya Popil (215) 446-5810
1 25/26/2017
01/17/2018
12:00 PM (EST)
14 Days of GMP Exercise
17. The offeror agrees to perform the work required at the prices specified below in strict accordance with the terms of this solicitation, if this offer is accepted calendar days after the date offers are due. (Insert any number equal to or greater than the minimum requirement by the Government in writing within stated in Item 13d. Failure to insert any number means the offeror accepts the minimum in Item 13d.)
OFFER (Must be fully completed by offeror)
AMOUNTS
18. The offeror agrees to furnish any required performance and payment bonds.
19. ACKNOWLEDGMENT OF AMENDMENTS
(The offeror acknowledges receipt of amendments to the solicitation -- give number and date of each)
AMENDMENT
NUMBER
DATE.
AWARD (To be completed by Government)
CONTRACTING OFFICER WILL COMPLETE ITEM 28 OR 29 AS APPLICABLE
14. NAME AND ADDRESS OF OFFEROR (Include ZIP Code)
CODE FACILITY CODE
15. TELEPHONE NUMBER (Include area code)
16. REMITTANCE ADDRESS (Include only if different than Item 14.)
20a. NAME AND TITLE OF PERSON AUTHORIZED TO SIGN OFFER (Type or print)
21. ITEMS ACCEPTED:
22. AMOUNT
26. ADMINISTERED BY
30a. NAME AND TITLE OF CONTRACTOR OR PERSON AUTHORIZED TO SIGN (Type or print)
31c. DATE
STANDARD FORM 1442 (REV. 8/2014) BACK
31b. UNITED STATES OF AMERICA
BY
31a. NAME OF CONTRACTING OFFICER (Type or print)
29. AWARD (Contractor is not required to sign this document.) Your offer on this solicitation is hereby accepted as to the items listed. This award consummates the contract, which consists of (a) the Government solicitation and your offer, and (b) this contract award. No further contractual document is necessary.
30b. SIGNATURE 30c. DATE
28. NEGOTIATED AGREEMENT (Contractor is required to sign this document and return and deliver all items or perform all work requirements identified on this form and any continuation sheets for the consideration stated in this contract. The rights and obligations of the parties to this contract shall be governed by (a) this contract award, (b) the solicitation, and (c) the clauses, representations, certifications, and specifications incorporated by reference in or attached to this contract.
copies to issuing office.) Contractor agrees to furnish
24. SUBMIT INVOICES TO ADDRESS SHOWN IN
(4 copies unless otherwise specified)
23. ACCOUNTING AND APPROPRIATION DATA
ITEM 25. OTHER THAN FULL AND OPEN COMPETITION PURSUANT TO
27. PAYMENT WILL BE MADE BY
10 U.S.C. 2304(c) ( ) 41 U.S.C. 3304(a) ( )
20b. SIGNATURE 20c. OFFER DATE
3PQCP
GSA CONTRACTS OPS BRANCH - PA NJ & DE SECTION
100 S. INDEPENDENCE MALL WEST
PHILADELPHIA, PA 19106
Nadya L. Popil
| Amendment 0015 Clarifications.pdf |
| Sheet1 |
| L102 Ground Floor Layout and Grading Plan.pdf |
| Sheets and Views |
| L-102 |
| L103 L01 West Layout and Grading Plan.pdf |
| Sheets and Views |
| L-103 |
| L104 L01 East Layout and Grading Plan.pdf |
| Sheets and Views |
| L-104 |
| A400.pdf |
| Sheets |
| A400 - WALL TYPES & PARTITION DETAILS |