Solicitation Questions and Responses2.pdf

PDF 248 KB Posted

Attached to
POCH/INTERIOR RENOVATIONS
Solicitation number
GS-03P-10-AZ-C-0039
Issued by

About this file

Questions/Answers 2

View the file

Other files

File Type Posted
SF1442POCH4.pdf PDF
SF30POCH4.pdf PDF
06500 Add 2.doc DOC document
15900 Add 2.doc DOC document
08750 Add 2.doc DOC document
15752 Add 2.DOC DOC document
15910 Add 2.doc DOC document
08710 Add 2.doc DOC document
08000-Door Schedule Add 2.xls XLS spreadsheet
SF1442POCH3.pdf PDF
09001 Room Finish Schedule Notes Add 2.doc DOC document
15840 Add 2.DOC DOC document
01260 Add 2.doc DOC document
08000 Add 2.doc DOC document
09000 FinMatSched Add 2.doc DOC document
TOC Add 2.doc DOC document
15725 Add 2.DOC DOC document
15838 Add 2.doc DOC document
15056 Add 2.doc DOC document
SF30PochInteriors3.pdf PDF
15817 Add 2.doc DOC document
Cover sheet Add 2.DOC DOC document
09900 Add 2.doc DOC document
09001-RmFinishSched Add 2.xls XLS spreadsheet
POCHINTAddendum 3 all 1 .pdf PDF
POChINTamend2sf30.pdf PDF
SF30POCHINTERAMED001.pdf PDF
POCHINTAMENDMENT.pdf PDF
Solicitation Questions and Responses 10-29-10.pdf PDF
pochinteriorsC101_Negotiated.doc DOC document
20100826 Issued for Const.pdf PDF
POCHSF1442interiors.pdf PDF
pochinterC301.doc DOC document
Addendum 1 Drawings.pdf PDF
C201SolpochInter.doc DOC document
Final Spec 2010-0823.pdf PDF
Addendum 1 Specs.pdf PDF
PA1_dvb.mht MHT file
Show all 38

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

No. Question Response

Reference Specification Section 08000, General

Notes: General Note 13 in Section 08000, Door

Schedule states some doors at the 10th floor main corridor were purchased in an earlier project and may exist on site. These are available to the contractor, however the contractor is responsible for confirming availability and suitability of these doors. Please provide the amount of doors that were purchased for the earlier project.

For bidding purposes, assume no doors were purchased.

Reference Specification Section 08000, General

Notes: General Note 13 in Section 08000, Door

Schedule states some doors at the 10th floor main corridor were purchased in an earlier project and may exist on site. These are available to the contractor, however the contractor is responsible for confirming availability and suitability of these doors. Please clarify if the door hardware was also purchased for these doors.

For bidding purposes, assume no door hardware was purchased.

Reference Specification Section 08715, Hardware

Set Schedule: Hardware Set 1113 states that the new hardware is to match and replace existing hardware. Please provide the make and model of the existing door hardware.

The existing door hardware is building standard. Standard building locksets are Best

Lock Co. For specific information, refer to specification sections 08710 and 08715.

Reference Specification Sections 08715, Hardware

Set Schedule: Hardware Set 1115 states that the new hardware is to match and replace existing hardware but replace lockset with panic device with alarm and time delay. Please clarify the make, model of the panic hardware.

Make of the building standard panic hardware is listed under Exit Devices (2.1 F) in specification section 08710. Specific model number to be provided after award.

Please identify where the existing shut off valves are for the bathrooms to be renovated. We would like to see if the bathrooms can be individually isolated the way they are currently installed.

Requested information is provided on sheets

M4.01, M4.02 and M4.03. Existing shut-off valves are capped and new shut off valves serve each pair of toilet rooms.

POCH Interiors Renovation

Solicitation Questions and Responses

Please confirm that the only asbestos/hazardous waste abatement is on the ten floor as shown on drawings ENV 10 01 and ENV 10 02

Specifications Section 02085, Asbestos

Abatement Procedures, is deleted in

Amendment 2. Based on ACM survey undertaken prior to this contract, it is believed that no ACMs will be impacted by the current scope of work below the Ninth Floor. Survey at impacted areas of the Ninth and Tenth

Floors has indicated presence of ACMs at the

Tenth Floor only. Should any additional ACM be encountered in any work area, the

Contractor is to abate in accordance with

Section 02080.

See responses to Questions 29, 30, and 31 for other hazardous materials.

Note 4 on drawing ENV 10 01 and ENV 10 02 states

"Fluorescent light bulbs and ballasts in the project area are considered regulated materials". Does this note apply to only the tenth floor or does it pertain to the other floors within this project scope as well?

See response to Question 29.

Note 5 on drawing ENV 10 01 and ENV 10 02 states

"Thermostats in the project area are considered regulated material". Does this note apply to only the tenth floor or does it pertain to the other floors within this project scope as well?

See response to Question 30.

Drawings A 1 26 & A 1 27 RCP, Tenth Floor Demo

RCP Plan - North & South, does not seem to reflect the current demolished state of the tenth floor as observed in the work through. Is there a revised drawing showing the current state of the 10th floor that is to be demolished?

The drawings generally reflect existing conditions, sufficient to define the scope of work. Reference General Note 7 on Sheet

G.0.04. Bids are to be put together in accordance with the drawings and specifications.

Provide quantities for all hazmat items to be removed? A hazmat report with quantities are required to price.

See Specifications Section 02080, Asbestos

Abatement, reissued with Amendment 2.

Terrazzo cannot be installed over nights. Will the floors be able to be shut down over entire weekends to install in sections? Confirm work can occur days and nights on weekends. Also how do we deal wit the USMS area that says open 24/7.

There will need to be rerouting of traffic or weekend shut down.

Work is able to be performed during days and nights during the weekends with proper coordination and advanced notice with the

CM. Access must be guaranteed to the courtrooms/chambers and ends of the cooridors. Rerouting will be necessary, and stairwells can be utilized for this. Complete shut downs are not possible.

Options say up to 120 days for approval. This is very hard to get subcontractors to hold price this long. Can this be shortened?

GSA is unable to guarantee that options will be approved in less than 120 days. This is not able to be shortened.

Can phase 8 start earlier than listed for the 10th floor? Does the building have any restrictions to

See answer to question 52. All bids should be submitted in accordance to the drawings and specifications, inclusive of phasings.

Does the building have any restrictions when starting floors 3 and 5 work?

All DHS and Building security requirements must be adhered to as per the contract and specifications. Additionally, all work must be performed with minimal tenant disturbance.

The specs say other projects will be going on.

Please provide information of how the elevators, trash routing, dumpsters will be coordinated to allow efficient work flow?

Coordination amongst the various projects going on within the building will be handled via the CM, inclusive of elevators, trash routing, and dumpsters. Based upon project progress meetings and projected work schedules, these issues will be coordinated as necessary.

There is a detail for the temporary partition.

Where do you expect this to be installed? We assume this is not required in areas that need to be reopened each day - please confirm

Install in areas as required to separate occupied building areas from construction zones. Partition detailed is not required in areas to be reopened each day.

Define refurbishing scope of existing clock. Note

16E on A2.10

Revise Note 16E to read, "Replace existing clock mechanism with UL rated mechanism.

Adjust as required to make clock operational."

50 Note 112-B shown but not defined. Please provide See response to Question 23.

51 Define scope for refurbishing jury chair 3 / A5.04

Revise Note 3, A.5.04 to read, "Clean existing jury chair with mild detergent and water. Wipe dry."

Phasing - why do we have to wait for phase 1 through 7 to be complete prior to starting remaining construction (phase 8) See M1.01

The General Contractor is required to submit of schedule of constrution for the completion of all with with minimal disruption to the building. The intent is to install the air handlers behind finished spaces after demolition and before the new work , restricting access to the mech rms. Also, please see the answer to question 45.

Mechanical gen'l note 1: Please define "will not be disturbed" There will be some disturbance to daily activities when restroom is down, corridor is being renovated etc.

It is assumed noise generating work will be required to complete the tasks. Noisy work generating complaints may cause work stoppages. Alternate toilet rooms in the building may be used during the renovation of some toilet rooms. A schedule of work needs to be submitted.

We assume corridors being renovated can be done in its entirety meaning ceilings and flooring completely demo'd with lights temporarily hung.

Work are will be left clean and safe at the end of each night. - Please confirm.

As per the specifications, all areas of occupied tenant space must remain accessible, operational , and clean for safe utilization during normal business hours.

M10.03 Note 3. Fill opening with like material is in conflict with architectural. We assume patching per Arch dwgs. Please confirm.

Revise General Note 3 on Sheets A.1.36 and

A.1.37 to read, "Patch exist wall surfaces to remain following removals. Match adj surfaces. Patch in kind, UNO." Revise Keynote

3, Sheets M.10.01 and M.10.02 to read, “Repair openings in wall where ductwork shall be removed. Refer to Architectural Dwgs for details. Coordinate infill with all new wall openings for new ductwork."

Note 7 Dwg M10.02. Says duct to be removed and disposed as directed by CM. Please provide plan for removal of duct and other materials.

The general contractor shall submit a plan and approach for removal of materials. The CM will be the owners rep for day to day operations.

Note 2 Dwg M10.05 Says to store fin tube and covers as directed by CM. We assume this can be stored on site - please confirm.

Fin tubes and covers are able to be stored on site. Storage of any salvaged materials shall be coordinated with the CM.

Please confirm that we can work areas day and night on weekends.

See answer to question 43.

Please confirm hygienist air sampling and testing is by the GC

Air sampling and monitoring is to be conducted by the GC as per specification section 02080.

Need spec for this scope of work (Mechanical

Commissioning)

Specification 15910, Commissioning of HVAC was issued with Amendment 1.

Due to all the information still required in the short time left, a time extension will be required to price.

Will a time extension be provided.

Bids will now be accepted until November

17th, 2010 at 3PM and in accordance with the solicitation documents.

1140 1.2 B13 We assume concrete floors and partial install of terrazzo floors are adequate for safe access for tenants. Please confirm.

As per the specifications, it is the contractors responsibility to maintain safe access for tenant utilization in occupied areas. Concrete

Floors are OK for safe passage as acceptable to the CM. Terrazzo in process will not be safe for public access. Coordination of safe routes will be scheduled through the CM.

1140 1.3 B3 We assume warranty period start at completion and acceptance of areas not the occupancy by the Government since we do not know when it will be occupied. Please confirm

Warranty Period(s) commence upon substantial completion and acceptance by the

Government.

1140 1.4B and E Conflicts is duration of notification of working outside the 6 am to 6 pm time. We feel the notification is 72 hours not 10 days because it will be very hard to predict if weekend work will be needed two weeks out. Please confirm.

The notification time stated is due to the nature of the building security and cannot be shortened.

65 Is this part of the base or an option? (Option 3)

Base and options have been revised in

Amendment 1 (reference Specifications

Section 01260, Base and Options.)

Are these required with bid? Is GSA providing a form to do so? Please keep in mind having nine options and 25 unit prices along with a base bid is highly unusual and almost unrealistic on a lump sum competitive bid. Bids are received up to minutes before it is due to GSA.

The revised SF1442 is provided in this amendment to be used as a unit pricing form.

Unit prices are required given the nature of the existing building.

1500 1.2 A,B,C: A says we pay, B, C, D says we do not pay for utility usage. We assume we do not pay for utility usage - please confirm.

Contractor is not required to pay for usage of utilities identified in 1.2.B through D. Charges for usage of all other utilities are to be paid by the Contractor.

00900 We assume these competent of specialty construction personnel are not due with the bids but in submittals after award. Please confirm

See response to Question 4.

1100 1.4 A 5 Please quantify the doors for the

10th floor that are available. Also please ascertain if available and suitable since we have no clue.

See response to Question 33.

The unit prices specify 2,300 square meters of leveling included in the base bid, but at what average depth should we carry for the leveling compound.

Specifications Section 01270, Unit Prices, has been reissued in Amendment 2. Refer to revised Unit Price No. 9.

Due to the amount of questions and the level of uncertainty of the existing site conditions, can an additional site visit be coordinated?

As per the pre-proposal conference, in addition to the site walk through on October 27, 2010, additional site visit days were established for

October 29, 2010 and November 1, 2010. Due to the Schedule constraints of the Building

Manager, additional site visits are not available.

The ornamental metal spec discusses extending aluminum column covers to the finish ceiling.

Where are these shown on the documents?

Covers are shown on Detail 06/A.5.10. This detail occurs at Judges Elevator Lobbies C2-

1003L and C3-1003L, as referenced on sheet A.

1.36 and A.1.37, respectively.

Drwg A-1-10 There are existing carpet squares to be removed behind the partitions to be removed

@ 8.3 X B.5 in current URS space

Sheet A.1.10 has been revised to show carpet removal in this area in Amendment 2.

Drwg. A-1-25 9th Fl Demo shows lay-in ceiling to be removed in Jury Rm C 905 G. However Drwg A-1-45 shows partial replacement of ceiling. Please clarify.

Existing suspended ceiling is being removed.

Existing plaster ceiling above is being patched and repaired. Note additional patching requirements have been included in

Amendment 1.

Drwgs A-1-30 and A-2-01 There is new GWB on either side of corridor 106a. Drwgs seem to suggest

GWB on existing frame. Drwg A-1-10 shows no demo of existing GWB wrapping the corner. Please clarify.

GWB in Corridor is existing to remain, with limited areas of patching at removal of existing partitions and fire hose cabinet, per Note D37

Sheet A.1.10 and General Note 3 Sheet A.1.30.

Drwg A-2-02 Detail 10 for South El. does not show new GWB at line 4.5 and it does show the new

GWB at lines 7 and 5.7 on existing frame in line with existing wall behind current GWB to be removed. Please clarify.

New GWB is required at Column Line 4.5.

Detail has been revised in Amendment 2.

Are the ballasts and/or lamps from demo being recycled?

See response to Question 29.

Who owns the scrap (e.g. wire, etc.) from the demo?

The General Contractor, per Section 1732, Selective Demolition, 1.2.A.

We have recently been informed that the General

Services Administration has increased its sustainability requirements and now mandates

LEED Gold for its projects. Is that true for this project?

The sustainability requirements referred to are for new construction projects and do not impact this project.

Refer to specification section 02085 section 1.04 A, "Initial Submittals of Asbestos Abatement

Contractor or Subcontractor Qualification

Information". This section details qualification requirements that state are to be submitted at with the contractors bid. Please confirm that this is a necessary requirement at the time of bid.

Specifications Section 02085, Asbestos

Abatement Procedures, is deleted, and replaced with Section 02080, Asbestos

Abatament, in Amendment 2. Submittal requirements at time of bid are identified in

1.4.B of that section. [GSA confirm].

Can the AWI certification requirement for the

Architectural casework be waived for this project?

No, the AWI certification requirements will not be waived for this project.

Solicitation Questions and Responses in amendment #1 stated that the SF1442 has been revised. Where can we get this revised form? The one on the website, there is no place on the bid form to provide the 20 plus unit prices. Are we to include the unit price cost with our submission?

The revised SF1442 is provided in this

Amendment (#2). Yes, the unit price costs are to be included in your submissions.

Are we to carry the quantities indicated in section

01270 unit prices in our bid? The quantities indicated for the Asbestos contained items do not match the quantities indicated in specification section 02080 Asbestos Abatement. Also, are these quantities beyond what are shown on the demolition drawings or does these quantities included what is shown on the drawings?

Yes. Specifications Section 01270, Unit Prices, has been reissued in Amendment 2. Refer to revised Unit Prices No. 2, 3, 7, and 11. These quantities reflect work shown on the Drawings.

The Schedule of Base Bids and Options, pages 2 and 4 of Standard Form 1442, are different than what is called out in Section 01260 Options. Please advise.

See response to Question 65. Please see the revised SF1442 as included in this amendment.

Please verify that the statement within the double lines and bolded block on many Electrical drawings is correct (ie: NOT ALL KEY NOTES USED ON THIS

SHEET). All drawings containing this Note have several demolition and/or new work notes described but that are not shown on the demolition or new work plans. We understand the statement within the block to mean that if any particular note is not located on the demolition and/or new work plans on any given drawing that the work in NOT require don that particular drawing. Please confirm.

Correct, keynotes actually shown on each

Drawing define the scope of work on that

Drawing. General Notes on each Drawing, however, apply in full.

Please clarify that the New Work Notes describing the requirement for 120V power wiring to flush valve transformers is also a requirement for 120V power wiring to automatic faucet transformers

(this work is depicted but not described in the new work notes).

The 120v circuit provides power to the low voltage transformers used at the faucets and flush valves in the public toilet rooms.

Please clarify that the new work notes describing the low voltage power wiring to each flush valve is also a requirement for low voltage power wiring to each automatic faucet (this work is depicted but now described in the new work notes).

The drawings require a single low voltage control transformer to be installed and used to power the lavatory faucets and flush valves for the toilets and urinals. All low voltage wiring shall be installed between the transformer and the fixtures served. This condition is required for all public toilet room work on the 1st, 2nd, 3rd, 5th, and 10th floor.

Solicitation Questions and Responses in amendment #1 make several references to

Addendum #2. When and where is this addendum going to be available?

Addendum #2 refers to the information provided by Shalom Baraned Associates in

Amendment #1 issued by GSA and has been available. Additional information is being issued with this Amendment.

Could you please confirm that there is no duct liner on this job.

No new ductwork is intended to have duct lining. Some existing ductwork may require repair where ducts are modified.

Reference Specification Section 07590 4.2.1, Materials: The roofing material is specified as

“Matching the existing roofing system.” Please identify who the manufacturer is for the existing roofing system.

According to building management, the existing roofing system is a Firestone SBS two -ply system.

Reference Drawings A-1-11, A-1-12 & A-1-13:

General Note 3 states where floor finish removal is indicated, remove all existing floor finishes down to existing concrete slab, UNO. Assume one layer of carpet on padding over resilient tile, Typ., UNO.

However, the legend on these drawings state to remove existing carpet, resilient base. Please clarify as to which note is applicable to these areas of floor demolition.

Delete text "Assume one layer of carpeting on padding over resilient tile, typ UNO" from

General Note 3 on Sheets A.1.10, A.1.11, A.1.12, and A.1.13.

Reference Drawing A-1-16, Note 4: General Note 4 states that where floor finish removal is indicated, remove all existing floor finishes down to existing concrete slab, UNO. Assume one layer of carpet on padding over resilient tile, Typ., UNO. Please confirm that this is accurate for all demolition of flooring on the 10th Floor.

Confirmed, note applies to all areas of floor finish removal, with exceptions as identified via keynotes.

Reference Demolition Drawings: As per the site visits there seem to be differences in the demolition drawings for the ceilings. There seem to be areas that are already demolished where as the drawing indicate these areas to be demolished.

Please clarify if we are to bid as seen or there will be another set of demolition drawings issued.

See response to Question 41.

Reference Drawing A-4-06: The existing Jury Box shows (8) Juror chairs. However, on the site visit, we saw that the existing Jury Box has (16) chairs.

Please clarify how many chairs will be salvaged, restored, and reinstalled.

Salvage existing seats for reuse as required from any of the existing Tenth Floor courtrooms, per Keynote D02, Sheets A.1.16 and A.1.17. Per Sheet A.4.06, a total of eight seats will be required. Note that not all existing seats are in condition for reuse; those salvaged and reinstalled should be in good condition requiring cleaning only.

Reference Drawing A-4-06: The new Jury Box shows (8) Juror chairs on an existing platform.

However, on the site visit, we saw that the existing

Jury Box has (16) chairs. Please clarify if we are to use the existing platform or if a new platform needs to be constructed.

Existing platform is to be salvaged and modified for reuse per Keynote 101, Sheet

A.4.06. Revised sheets A.1.17 and A.4.06 are issued in Amendment 2.

Reference Drawings A-4-06: The Legend indicates

Acoustically Treated Walls, however there is no spec section on this and the Legend is cut off at the bottom. Please clarify.

Revise legend note to read, "Indicates acoustically treated walls. All penetrations and doors to be acoustically sealed. Re:

12/A.5.03." Reference Sheet A.6.02 for partition types. Delete the following text from

General Note 6, Sheet A.6.02 : "RE A.4.06 &

A.4.07 for extent of acoustically treated partitions (both new & exist)."

Reference Drawings A-1-33: Room 216, South

Lobby, indicates Terrazzo flooring as per the plan legend. This room is not on the Finish Schedule.

Please clarify finishes for this area.

The Finish Schedule is reissued in Amendment

2, with Room 216 added and Room 201 revised. Finish work in this area includes replacement of existing flooring and wall base, and removal of existing wallcovering and painting of walls.

Reference Spec Section 01270, Unit Prices: Each

Unit price requested specifies a “Base Bid Quantity included in the Contract Documents”. Please clarify if these unit prices and our base bid are to be based on the quantities given.

Confirmed. Note Specifications Section 01270, Unit Prices, is reissued in Amendment 2.

Reference Drawings M-10-20 and M-10-20:

Drawing M-10-20 states new housekeeping concrete pads to be installed for new AHU-10E and

AHU-10D. However, there does not appear to be a detail provided for housekeeping concrete pads to be installed for the new AHU to be installed for

Options 2 & 4. Please confirm if there are to be no housekeeping pads installed for the AHU’s in

Option 2 & 4.

Refer to Note 8 on Sheet M.10.15 (the air handler unit configuration drawing) for the requirement of a new concrete housekeeping pad under all new and replacement air handlers.

Reference Drawing A-1-50: Drawing A-1-50 does not indicate the need for access to every floor for the flue shaft work. Please clarify if we will be able to access the 2nd, 4th and 8th flue shaft areas for clean up and installing the Syphonic Piping.

Drwgs clearly state where access to flue is to be attained. Contractor can work in flue above and below for work thru floors 4 and 8.

Reference Drawing A-1-50: Please verify that there is floor and decking at each floor location of the flue shaft area.

There is no existing floor decking inside the vertical shaft at each floor. Where the existing flue changes direction, there are floors following the horizontal transition. Work to install and support the new drain must be done from the existing floors outside the shaft, through the new or existing openings, or on temporary platforms/scaffolding provided by the Contractor.