Final Drawings_Part7.pdf
PDF 18 MB Posted
- Solicitation number
- 36C77622R0069
About this file
This document outlines a federal contract opportunity for infrastructure upgrades at a Department of Veterans Affairs facility. The solicitation calls for construction services to complete EHRM Infrastructure Upgrades at a location in Columbia, Missouri. The contractor will be responsible for providing all labor, project management, materials, tools, supplies, and equipment as required by the drawings and specifications to finish the necessary work for the project. The solicitation number is 36C77622R0069 and was issued by the Department of Veterans Affairs Technology Acquisition Center located in Austin, Texas.
View the file
Other files
Show all 31
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
#4
#5
#7
#8
UPDN
#1#2#3 #1
OPEN TO
ROOF ACCESS
BELOW
UP
DN
STR #1
441 442 443A 443B 443C
444443K437
443D 451 454A
454 454B
454D
454C
455A
C45
445 448 452 456
443E443F
449 458
457A
443G
463A464465466433
431A
428A
C
427A
401A
C41
416416A419
425A 423A 420A C43 417A 415A 414 412C 412B
413A
ST
R
411A
C
405A
407A
411413415417420
414B
423425
426A
410A
439 451A
443H
401B 401C
NO ROOF
ACCESS
NO ROOF
ACCESS
NO ROOF
ACCESS
DN
NO ROOF
ACCESS
G400
F400
ST
R
F401
F402
DN
NOT IN SCOPE.
PROJECT 589A4-19-103
NOT IN SCOPE.
AREA TO BE RENOVATED IN 2023
TS-204-1.4
FOURTH FLOOR
SECURITY PLAN
RMJr
1 SECURITY - OVERALL FLOOR PLAN - FOURTH FLOOR
SCALE: 1" = 20'
N
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
589A4-21-700
1/25/2022
100% CONSTRUCTION
DOCUMENT
EHRM Infrastructure Upgrades - Columbia, MO
800 HOSPITAL DRIVE
COLUMBIA, MO 652016 S. OLD ORHCARD AVE.
WEBSTER GROVES, MO 63119
PHONE #: 314-918-8383
Consultant POC
#7
#8
UP
DN
U P
D N
#2#3 #1
#4
#5
F
F
F F
F
F
EXIST.
ROOM
EXIST.
TELECOM
5/TS-401
TS-205-1.5
FIFTH FLOOR
SECURITY PLAN
RMJr
1 SECURITY - OVERALL FLOOR PLAN - FIFTH FLOOR
SCALE: 1" = 20'
N
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
589A4-21-700
1/25/2022
100% CONSTRUCTION
DOCUMENT
EHRM Infrastructure Upgrades - Columbia, MO
800 HOSPITAL DRIVE
COLUMBIA, MO 652016 S. OLD ORHCARD AVE.
WEBSTER GROVES, MO 63119
#2#3 #1
DN
F
F
F
F
#4
#5
UP
DN
625B
623 625F
625C 625D
619 615A
C67
625E 612A
615 614
612B 612C
613C 613B
612D
612G
612F
612E
STR #1
632A
645 646 647 648 656 657 663 664 666 668 670
607608
ST
R
605604603683
C
667665660
662656B
C65
660A 676 675
C003
682685
C004686
656A
670A 659 658
624654
650A
C
601A
601B
C
C63
617618621622
C
625A632
C
626A
C
C69
652A653
C71
C61
601C
EXIST.
TELECOM
6/TS-401
1 SECURITY - OVERALL FLOOR PLAN - SIXTH FLOOR
SCALE: 1" = 20'
TS-206-1.6
SIXTH FLOOR
SECURITY PLAN
RMJr
N
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
589A4-21-700
1/25/2022
100% CONSTRUCTION
DOCUMENT
EHRM Infrastructure Upgrades - Columbia, MO
800 HOSPITAL DRIVE
COLUMBIA, MO 652016 S. OLD ORHCARD AVE.
WEBSTER GROVES, MO 63119
UP 24R
D
E
F
J
M
B.9
D.4
E.5
STORAGE
K006
K0
K005
K0
K0
STORAGE
K002
ELEC.
ROOM
K003
MED.
GAS
EQUIPMENT
ROOM
K004
CORRIDOR
C0K03
LOADING
K005
MECHANICAL
K001
A
B.1
H.2
STAIR
K053
ELEV
P-18
CORRIDOR
C0K01
K001
K0
1.7
1.7
C
K0
A
K0
STORAGE
K007
1.5
K
6.2
N
B
P
10 11 12 13
G
8 9
H
G.5
P-18A
K0
N.5
C1K18
7/TS-401
TS-207-2.B
BASEMENT FLOOR
SECURITY PLAN
RMJr
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
589A4-21-700
1/25/2022
100% CONSTRUCTION
DOCUMENT
EHRM Infrastructure Upgrades - Columbia, MO
800 HOSPITAL DRIVE
COLUMBIA, MO 652016 S. OLD ORHCARD AVE.
WEBSTER GROVES, MO 63119
A060
TELECOM
ROOM
A060
TELECOM
DEMARK ENTRANCE
A060A
1 ENLARGED PLAN - TELECOM ROOM A060A
SCALE: 1/4" = 1'-0"
E006
EXIST.
TELECOM
E006
2 ENLARGED PLAN - TELECOM ROOM E006
SCALE: 1/4" = 1'-0"
G050EXIST.
TELECOM
G050
3 ENLARGED PLAN - TELECOM ROOM G050
SCALE: 1/4" = 1'-0"
N N N N
4 ENLARGED PLAN - TELECOM ROOM W05B
SCALE: 1/4" = 1'-0"
W05B
EXIST.
TELECOM
W05B
D
EXIST.
TELECOM
A153A
5 ENLARGED PLAN - TELECOM ROOM A153A
SCALE: 1/4" = 1'-0" 6 ENLARGED PLAN - TELECOM ROOM E139
SCALE: 1/4" = 1'-0" 7 ENLARGED PLAN - TELECOM ROOM B144A
SCALE: 1/4" = 1'-0"
N N N N
8 ENLARGED PLAN - TELECOM ROOM G141
SCALE: 1/4" = 1'-0"
9 ENLARGED PLAN - TELECOM ROOM C105
SCALE: 1/4" = 1'-0" 10 ENLARGED PLAN - TELECOM ROOM E203
SCALE: 1/4" = 1'-0"
N N
E138
E139
TV
EXIST.
TELECOM
E139
TV
EXIST.
TELECOM
B144A G141
EXIST.
TELECOM
G141
C105
EXIST.
TELECOM
C105
E202
E203
EXIST.
TELECOM
E203
KS
PB
CR
PB
CRKS
PB
CRKS
PB
CRKS
C
RPB
KS
PB
CR KS
C R
KS
PB
CR
KS
PB
C R
KS
C R
KS
PB
11 SYMBOLS LEGEND AND GENERAL SECURITY NOTES
SCALE: N.T.S.
KS
PB
CR
CARD READER WITH KEYPAD
PUSH BUTTON (REX)
KEY SWITCH
ELECTRONIC STRIKE LOCK
ELECTRIFIED LOCK SET
REQUEST TO EXIT (REX) PIR SENSOR
DOOR CONTACT
E = DENOTES EXISTING
ES
ES
ES
ES
ES
EL
ES
ES
ES
ES
ES
E E
E
EE
E
E
EE
E
E
E E
E E
EE
E E
E E
E E
EE
E E
E E
E E
E E
E E
EE
E
E
GENERAL SECURITY NOTES:
1. CONTRACTOR SHALL RELOCATE EXISTING FIELD HARDWARE FOR DOORS
THAT ARE BEING RELOCATED OR REPLACED. REFER TO DOOR SCHEDULE,
ARCHITECTURAL PLANS AND TS-500 FOR DETAILS.
2. CONTRACTOR SHALL PROVIDE NEW FIELD HARDWARE FOR NEW TR DOORS.
REFER TO TS-500 FOR DETAILS.
3. CONTRACTOR SHALL INSTALL REX PIR SENSORS FOR DOORS WITH ELECTRIC
STRIKE LOCKS. REFER TO TS-500 FOR DETAILS.
4. PATCH AND PAINT ANY HOLES IN HARD CEILING OR WALLS TO MATCH
EXISTING. COORDINATE WITH ARCHITECT.
EL
PIR
PIR E
DC
DC
DC
D C
DC
DCDC
D
CD
C
DC
DC
DC
D C
DETAIL NOTE: EXISTING FIELD HARDWARE TO BE RELOCATED.
DETAIL NOTE: EXISTING FIELD HARDWARE TO BE RELOCATED.DETAIL NOTE: EXISTING FIELD HARDWARE TO BE RELOCATED.DETAIL NOTE: EXISTING FIELD HARDWARE TO BE RELOCATED.DETAIL NOTE: EXISTING FIELD HARDWARE TO BE RELOCATED.
DETAIL NOTE: EXISTING FIELD HARDWARE TO BE RELOCATED.
DETAIL NOTE: EXISTING FIELD HARDWARE TO BE RELOCATED.
TS-400
BLDG. 1 - SECURITY
TELECOM ROOM - ENLARGED PLANS
RMJr
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
589A4-21-700
1/25/2022
100% CONSTRUCTION
DOCUMENT
EHRM Infrastructure Upgrades - Columbia, MO
800 HOSPITAL DRIVE
COLUMBIA, MO 652016 S. OLD ORHCARD AVE.
WEBSTER GROVES, MO 63119
1 ENLARGED PLAN - TELECOM ROOM A306A
SCALE: 1/4" = 1'-0" 2 ENLARGED PLAN - TELECOM ROOM C316
SCALE: 1/4" = 1'-0"
N
5 ENLARGED PLAN - TELECOM ROOM 551
SCALE: 1/4" = 1'-0" 6 ENLARGED PLAN - TELECOM ROOM 650
SCALE: 1/4" = 1'-0"
N N
A306A
EXIST.
TELECOM
A306A
EXIST.
TELECOM
C316
EXIST.
TELECOM
# SF
EXIST.
TELECOM
7 ENLARGED PLAN - ENTRANCE ROOM K007
SCALE: 1/4" = 1'-0"
N
K0
STORAGE
K007
C R
KS
PB
ES
EE
E
E
C R
KS
PB EE
E E
CR KS
ES
E E
E
CRKS
PB
ES
E
E E
E
CR KS
ES
TELECOM DEMARC
(ENTRANCE ROOM)
11 SYMBOLS LEGEND AND GENERAL SECURITY NOTES
SCALE: N.T.S.
3 ENLARGED PLAN - TELECOM ROOM C358C
SCALE: 1/4" = 1'-0"
N N
EXIST.
TELECOM
C358C
EXIST.
TELECOM
E326
E
E
E
E
CR KS
PB
C R
KS
PB EE
E
4 ENLARGED PLAN - TELECOM ROOM E326
SCALE: 1/4" = 1'-0"
N
ELEL
EEL
PIR
E
PIR
KS
PB
CR
CARD READER WITH KEYPAD
PUSH BUTTON (REX)
KEY SWITCH
ELECTRONIC STRIKE LOCK
ELECTRIFIED LOCK SET
REQUEST TO EXIT (REX) PIR SENSOR
DOOR CONTACT
E = DENOTES EXISTING
ES
GENERAL SECURITY NOTES:
1. CONTRACTOR SHALL RELOCATE EXISTING FIELD HARDWARE FOR DOORS
THAT ARE BEING RELOCATED OR REPLACED. REFER TO DOOR SCHEDULE,
ARCHITECTURAL PLANS AND TS-500 FOR DETAILS.
2. CONTRACTOR SHALL PROVIDE NEW FIELD HARDWARE FOR NEW TR DOORS.
REFER TO TS-500 FOR DETAILS.
3. CONTRACTOR SHALL INSTALL REX PIR SENSORS FOR DOORS WITH ELECTRIC
STRIKE LOCKS. REFER TO TS-500 FOR DETAILS.
4. PATCH AND PAINT ANY HOLES IN HARD CEILING OR WALLS TO MATCH
EXISTING. COORDINATE WITH ARCHITECT.
EL
PIR
DC
DETAIL NOTE: EXISTING FIELD HARDWARE TO BE RELOCATED.
DETAIL NOTE: EXISTING FIELD HARDWARE TO BE RELOCATED.
D216
D216A
9 ENLARGED PLAN - DATA CENTER D216 MIDDLE DOOR
SCALE: 1/4" = 1'-0" 10 ENLARGED PLAN - DATA CENTER D216 - SOUTH DOOR
SCALE: 1/4" = 1'-0"
N
D C
D C
DC
D C
DC
DC
DC
C R
KS
PB
ES
EE
E
E D
C
C R
KS
PB
ES
EE
E
E D
C
DETAIL NOTE: EXISTING FIELD HARDWARE TO BE RELOCATED.DETAIL NOTE: EXISTING FIELD HARDWARE TO BE RELOCATED.
DETAIL NOTE: EXISTING FIELD HARDWARE TO BE RELOCATED.
RAMP UP
8 ENLARGED PLAN - DATA CENTER D216 - NORTH DOOR
SCALE: 1/4" = 1'-0"
N
C R
KS
PB
ES
EE
E
E D
C
DETAIL NOTE: EXISTING FIELD HARDWARE TO BE RELOCATED.
N
TS-401
BLDG. 1 - SECURITY
TELECOM ROOM - ENLARGED PLANS
RMJr
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
589A4-21-700
1/25/2022
100% CONSTRUCTION
DOCUMENT
EHRM Infrastructure Upgrades - Columbia, MO
800 HOSPITAL DRIVE
COLUMBIA, MO 652016 S. OLD ORHCARD AVE.
WEBSTER GROVES, MO 63119
1 TYPICAL ACCESS CONTROL - SINGLE DOOR DETAILS
SCALE: N.T.S. 2 TYPICAL ACCESS CONTROL - DOUBLD DOOR DETAILS
SCALE: N.T.S.
DASHED BOX INDICATES
EQUIPMENT ON OPPOSITE SIDE
VIEW FROM NON-SECURE SIDE
FLOOR
CEILING
J-BOX
DC
DASHED BOX INDICATES
EQUIPMENT ON OPPOSITE SIDE
VIEW FROM NON-SECURE SIDE
ES
FLOOR
CEILING
J-BOX
CR
DC
PIR
KS
DASHED BOX INDICATES
EQUIPMENT ON OPPOSITE SIDE
VIEW FROM NON-SECURE SIDE
FLOOR
CEILING
J-BOX
DC DC
KS
LEAF 1LEAF 2
BOLTED LEAF
X ES
CR
KEYED NOTES:
1. (2) A, (2)L, I, O, IN 1-1/4" (32MM) C TO
PORTAL INTERFACE PANEL
2. 4-11/16" X 4-11/16" J-BOX WITH COVER
3. CARD READER WITH KEYPAD
4. BYPASS KEY SWITCH
5. DOOR POSITION SENSOR
6. TRANSFER HINGE
7. PASSIVE INFRARED REQUEST TO EXIT
SENSOR (REX PIR)
8. ELECTRIC STRIKE LOCK
GENERAL NOTES:
1. THE PORTAL SHALL BE SECURED BY ELECTRIC
STRIKE LOCK.
2. UPON A REQUEST TO EXIT OR A VALID CARD
READ (AND PIN CODE ENTRY DURING HIGH
SECURITY) THE BMS SHALL ENERGIZE THE
ELECTRIC STRIKE LOCK AND RELEASE THE
DOOR STRIKE.
3. WHEN DOORS ARE CLOSED, THE ELECTRIC
STRIKE LOCK SHALL DE-ENERGIZE AND THE
DOOR SHALL BE SECURE.
4. USING THE KEYSWITCH WILL CAUSE THE
ELECTRIC STRIKE LOCK TO ENERGIZE AND SEND
A KEYSWITCH USED SIGNAL TO THE ACS. THE
KEYSWITCH IS TO BE USED TO OVERRIDE THE
ELECTRIC STRIKE LOCK IN THE EVENT OF AN
ACS FAILURE.
PIR
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
589A4-21-700
1/25/2022
100% CONSTRUCTION
DOCUMENT
EHRM Infrastructure Upgrades - Columbia, MO
800 HOSPITAL DRIVE
COLUMBIA, MO 652016 S. OLD ORHCARD AVE.
WEBSTER GROVES, MO 63119
PHONE #: 314-918-8383
Consultant POC
TS-500
SECURITY PLAN - TYPICAL DETAILS
RMJr
X
M
T
PIPE LINE SYMBOLS
SHUT OFF VALVE (SEE
SPECIFICATION FOR TYPE)
GATE VALVE
BALL VALVE
BUTTERFLY VALVE
VALVE IN RISE (SEE SPECIFICATION FOR TYPE)
MULTI-PURPOSE PUMP DISCHARGE VALVE
CHECK VALVE
SOLENOID VALVE
PRESSURE REDUCING VALVE (HYDRONIC)
PRESSURE REGULATING VALVE (STEAM)
CALIBRATED - ORIFICE BALANCING VALVE
ACTIVE FLOW-LIMITING VALVE
PLUG VALVE
IN-LINE PUMP
Y-PATTERN STRAINER
Y-PATTERN STRAINER W/ BLOWDOWN VALVE
UNION
AIR VENT (M - MANUAL, A - AUTOMATIC)
RELIEF VALVE
VACUUM BREAKER
PRESSURE AND TEMPERATURE TEST PORT
THERMOMETER
PRESSURE GAGE WITH COCK
FLEX PIPE COUPLING
PIPE ANCHOR
PIPE GUIDE
PITCH DOWN IN DIRECTION OF ARROW
WATER METER
STEAM TRAP
TWO-WAY CONTROL VALVE
THREE-WAY CONTROL VALVE
MOTORIZED BUTTER FLY VALVE
GLOBE VALVE
A
UNIT NUMBER
EQUIPMENT DESIGNATION
TYPE OF SERVICE: S = SUPPLY
R = RETURN
E = EXHAUST
T = TRANSFER
AIR QUANTITY
IN CFM
SCHEDULED
DEVICE NO
UNIT NUMBER
DAMPER TYPE DESIGNATION
AIRFLOW MEASURING STATION
EXISTING EQUIPMENT DESIGNATION
S-1
FSD
AHU
AHU-1
ID-#
HVAC SENSOR
SENSOR TYPE
OPTIONS
SPECIALTY SENSOR TYPE
I = INSULATED BASE
G= PROVIDE GUARD
CO = CARBON MONOXIDE
CO2= CARBON DIOXIDE
NG = NATURAL GAS
T = TEMPERATURE SENSOR
H = HUMIDITY SENSOR
O = OCCUPANCY SENSOR
R = REFRIGERANT SENSOR
P = PRESSURE SENSOR
MECHANICAL SYMBOLS
ASSOCIATED UNIT
X Y
Z
ACCESS PANEL, TOP OR SIDE
TURNING VANES
MOTORIZED DAMPER
GRAVITY BACKDRAFT DAMPER
MANUAL VOLUME DAMPER
FIRE DAMPER
SMOKE DAMPER
FIRE/SMOKE DAMPER
FLOW ARROW DOWNSTREAM OF FAN
FLOW ARROW UPSTREAM OF FAN
SUPPLY DIFFUSER AS SCHEDULED. ARROWS INDICATE
DIRECTION OF AIR DISCHARGE. IF NO ARROWS ARE
SHOWN ON PLAN, DEFAULT IS A 4-WAY THROW
RETURN GRILLE OR REGISTER AS SCHEDULED
EXHAUST GRILLE OR REGISTER AS SCHEDULED
SLOT DIFFUSER AS SCHEDULED. ARROWS INDICATE DIRECTION
OF AIR DISCHARGE. IF NO ARROWS ARE SHOWN ON PLAN,
DEFAULT IS 2-WAY THROW
SIDEWALL DIFFUSER AS SCHEDULED
SIDEWALL RETURN OR EXHAUST AS SCHEDULED
DUCT SYSTEM SYMBOLS
12x12
12ø
12x10ø
FLEXIBLE DUCT
ROUND DUCT SIZE, (ACTUAL SIZE INDICATED)
CHANGE OF ELEVATION - RISE (R) OR DROP (D)
FLEXIBLE DUCT CONNECTION
SUPPLY AND OUTSIDE AIR SECTION UP
RETURN AIR SECTION UP
SPIRAL FLAT-OVAL DUCT SIZE, FIRST FIGURE
IS SIDE SHOWN (ACTUAL SIZE INDICATED)
R
DUCT SIZE, FIRST FIGURE IS SIDE
SHOWN (CLEAR INSIDE, ADJUST FOR
LINER)
SUPPLY AND OUTSIDE AIR SECTION DOWN
RETURN AIR SECTION DOWN
EXHAUST AIR SECTION UP
EXHAUST AIR SECTION DOWN
REFRIGERANT VENTRV
CHEMICAL FEEDCF
V VENT
CW COLD WATER, DOMESTIC
CWS
CA
CWR
CR
CS
CONDENSER WATER RETURN
CONDENSER WATER SUPPLY
CHILLED WATER RETURN
CHILLED WATER SUPPLY
COMPRESSED AIR
CHR
CHS
LPS
HWS
HWR
HPR
HPS
LPR
HG
RS
RL
PC
CHILLED/HOT WATER RETURN
CHILLED/HOT WATER SUPPLY
REFRIGERANT HOT GAS
REFRIGERANT SUCTION
REFRIGERANT LIQUID
PUMPED CONDENSATE
LOW PRESSURE CONDENSATE RETURN (15 PSIG)
LOW PRESSURE STEAM SUPPLY (15 PSIG)
HEATING WATER SUPPLY
HEATING WATER RETURN
HIGH PRESSURE CONDENSATE RETURN (100 PSIG)
HIGH PRESSURE STEAM SUPPLY (100 PSIG)
SRV STEAM RELIEF VENT
PUMP DISCHARGE
DRAIND
PD
DOMESTIC HOT WATERHW
MU MAKE-UP WATER (NON-POTABLE)
BLOW DOWNBD
CD CONDENSATE (STEAM) DRAIN
MPS
MPR
MEDIUM PRESSURE CONDENSATE
RETURN (60 PSIG)
MEDIUM PRESSURE STEAM SUPPLY (60PSIG)
PIPE SYSTEM ABBREVIATIONS
HORIZONTAL EXIT (& REFUGE AREA) FIRE BARRIER - 2HR
OCCUPANCY/AREA SEPARATION FIRE BARRIER - 2HR
NEW WORK BY THIS CONTRACTOR TO BE
INSTALLED UNDERGROUND, OR BELOW FLOOR
(DARK, CENTERLINE)
SUBDIVIDING SPACES SMOKE BARRIER - .5HR/1HR
BUILDING SEPERATION FIRE BARRIER - 2HR
EXISTING TO BE REMOVED BY THIS CONTRACTOR
(DARK, DASHED LINE, DEMOLITION PLANS)
EXISTING TO REMAIN OR NEW WORK BY OTHERS
(LIGHT, SOLID LINE)
NEW WORK BY THIS CONTRACTOR
(DARK, SOLID LINE)
LINE TYPE LEGEND
MECH EQUIPMENT DESIGNATION
MECH EQUIPMENT DESIGNATION
AC AIR CURTAIN
ACC AIR COOLED CONDENSER
ACU AIR CONDITIONING UNIT
ACV AIR CONTROL VALVE
AF AIR FILTER
AHU AIR HANDLING UNIT
AS AIR SEPARATOR
ATU AIR TERMINAL UNIT
B BOILER
BCU BLOWER COIL UNIT
BS BASKET STRAINER
BT BUFFER TANK
CAV CONSTANT AIR VOLUME
CB CHILLED BEAM
CC COOLING COIL
CFP CHEMICAL FEED PUMP
CH CHILLER
CP CONDENSER WATER PUMP
CRAC COMPUTER ROOM AIR CONDITIONING UNIT
CRP CONDENSATE RETURN PUMP
CSG CLEAN STEAM GENERATOR
CT COOLING TOWER
CTF COOLING TOWER FILTER
CU CONDENSING UNIT
CUH CABINET UNIT HEATER
CVR CONVECTOR
CWP CHILLED WATER PUMP
DFH DEAERATING FEEDWATER HEATER
DHU DESSICANT DEHUMIDIFICATION UNIT
DMC DUCT MOUNTED COIL
EAV EXHAUST AIR VALVE
EF EXHAUST FAN
EJ EXPANSION JOINT
ERU ENERGY RECOVERY UNIT
ET EXPANSION TANK
EVC EVAPORATIVE COOLER
F FAN
FAV FUME AIR VALVE
FC FLUID COOLER
FCU FAN COIL UNIT
FD FIRE DAMPER
FFU FAN FILTER UNIT
FSD COMBINATION FIRE/SMOKE DAMPER
FT FLASH TANK
FTR FIN-TUBE RADIATION
FTU FAN TERMINAL UNIT
GP GLYCOL PUMP
GV GRAVITY VENTILATOR
H HUMIDIFIER
HC HEATING COIL
HEV HOOD EXHAUST VALVE
HPU HEAT PUMP UNIT
HRU HEAT RECOVERY UNIT
HWP HEATING WATER PUMP
HX HEAT EXCHANGER
L LOUVER
MAU MAKE-UP AIR UNIT
MD MOTORIZED DAMPER
P PUMP
PAC PACKAGED AIR CONDITIONING UNIT
PC PUMPED CONDENSATE
PG PIPE GUIDE
PHWP PRIMARY HEATING WATER PUMP
PHX PLATE HEAT EXCHANGER
PRV PRESSURE REGULATING VALVE
PTAC PACKAGED TERMINAL AIR CONDITIONER
RF RETURN FAN
RHC TERMINAL REHEAT COIL
RP RADIANT PANEL
RTU ROOFTOP UNIT
SA SOUND ATTENUATOR
SAV SUPPLY AIR VALVE
SCWP SECONDARY CHILLED WATER PUMP
SD SMOKE DAMPER
SF SUPPLY FAN
SHWP SECONDARY HEATING WATER PUMP
SPP STEAM PRESSURE PUMP
ST STEAM TRAP
T TANK
TCP TEMPERATURE CONTROL PANEL
UH UNIT HEATER
VAV VARIABLE AIR VOLUME BOX
VFD VARIABLE FREQUENCY DRIVE
VI VIBRATION ISOLATION
VRF VRF INDOOR UNIT
WCC WATER COOLED CONDENSER
WSHP WATER SOURCE HEAT PUMP
MECHANICAL ABBREVIATIONS
A AIR OR AMP (PER CONTEXT)
ACC ACCESSORIES
AD ACCESS DOOR
AFF ABOVE FINISHED FLOOR
AFS AIR FLOW SWITCH
AHRI AIR CONDITIONING, HEATING, AND
REFRIGERATION INSTITUTE
AI ANALOG SIGNAL INPUT
AMB AMBIENT
AO ANALOG SIGNAL OUTPUT
AP ACCESS PANEL
APD AIR PRESSURE DROP
APLV APPLICATION PART LOAD VALUE
APPROX APPROXIMATE
ARCH ARCHITECTURE/ARCHITECT
AUX AUXILIARY
AV AUTOMATIC VENT
AVG AVERAGE
BDD BACK DRAFT DAMPER
BFC BELOW FINISHED CEILING
BFP BACKFLOW PREVENTER
BHP BRAKE HORSEPOWER
BI BINARY SIGNAL INPUT
BMS BUILDING MANAGEMENT SYSTEM
BO BINARY SIGNAL OUTPUT
BOB BOTTOM OF BEAM
BOD BOTTOM OF DUCT
BOP BOTTOM OF PIPE
BS BEAM SPACE
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNITS PER HOUR
BWE BAKED WHITE ENAMEL
CAP CAPACITY
CAV CONSTANT AIR VOLUME
CFH CUBIC FEET PER HOUR
CFM CUBIC FEET PER MINUTE
CI CAST IRON
CLG COOLING DUCT (COLD DUCT)
CO CLEAN OUT
COMP COMPRESSOR
CONC CONCRETE
COND CONDENSATE
CONN CONNECTION
CORR CORRIDOR
CV CONTROL VALVE
D DEPTH
DB DRY BULB
DBA A-WEIGHTED DECIBELS
DEFL DEFLECTION
DEG DEGREES
DEG F DEGREES FAHRENHEIT
DES DESIGN
DIA DIAMETER
DIM DIMENSION
DISCH DISCHARGE
DIV DIVISION
DN DOWN
DP DIFFERENTIAL PRESSURE SENSOR
DPS DIFFERENTIAL PRESSURE SWITCH
DPT DIFFERENTIAL PRESSURE TRANSMITTER
DTL DETAIL
DWG(S) DRAWING(S)
EA EXHAUST AIR OR EACH (PER CONTEXT)
EAT ENTERING AIR TEMPERATURE
EER ENERGY EFFICIENT RATIO
EFF EFFICIENCY
ELEC ELECTRIC
ELEV ELEVATION
EQ EQUAL
ESP EXTERNAL STATIC PRESSURE
EWB ENTERING AIR WET BULB TEMPERATURE
EWT ENTERING WATER TEMPERATURE
EXH EXHAUST
EXIST, EX EXISTING
EXT EXTERNAL
F FAHRENHEIT
F&T FLOAT AND THERMOSTATIC
FC FLEXIBLE CONNECTION
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FIN FINISHED
FLR FLOOR
FPF FINS PER FOOT
FPM FEET PER MINUTE
FS FLOW SWITCH
FT FEET
FT-HD HEAD IN FEET
GA GAUGE
GAL GALLONS
GALV GALVANIZED
GC GENERAL CONTRACTOR
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
H HEIGHT
HD HEAD
HEV HOSE END VALVE
HORIZ HORIZONTAL
HP HORSEPOWER
HR HOUR
HTG HEATING DUCT (HOT DECK)
HVAC HEATING, VENTILATING & AIR
CONDITIONING
HW HOT WATER
HZ HERTZ
IB INVERTED BUCKET
IE INVERT ELEVATION
IN INCH/INCHES
INDIC INDICATOR
IPLV INTEGRATED PART-LOAD VALUE
ISP INTERNAL STATIC PRESSURE
JS JOIST SPACE
KW KILOWATTS
L LENGTH
LAT LEAVING AIR TEMPERATURE
LB(S) POUNDS
LF LINEAR FEET
LRA LOCKED ROTOR AMPS
LS LIGHT SPACE
LVL LEVEL
LWT LEAVING WATER TEMPERATURE
MAN MANUAL
MANU MANUFACTURER
MAX MAXIMUM
MBH THOUSAND BRITISH THERMAL UNITS PER
HOUR
MCA MINIMUM CIRCUIT AMPS
MCC MOTOR CONTROL CENTER
MECH MECHANICAL
MERV MINIMUM EFFICIENCY REPORTING VALUE
(ASHRAE 52.2)
MFR MANUFACTURER
MIN MINIMUM OR MINUTE (PER CONTEXT)
MTD MOUNTED
MTL METAL
MV MANUAL VENT
NC NORMALLY CLOSED OR NOISE CRITERIA
(PER CONTEXT)
NIC NOT IN CONTRACT
NO NORMALLY OPEN OR NUMBER (PER CONTEXT)
NOM NOMINAL
NPLV NON-STANDARD PART LOAD VALUE
NPSH NET POSITIVE SUCTION HEAD
NTS NOT TO SCALE
OA OUTSIDE AIR
OBD OPPOSED BLADE DAMPER
OC ON CENTER
OD OUTSIDE DIAMETER
OT OIL TRAP
PA PIPE ANCHOR
PBD PARALLEL BLADE DAMPER
PD PRESSURE DROP
PENT PENTHOUSE
PH PHASE
PHC PREHEAT COIL
PLBG PLUMBING
PNEU PNEUMATIC
PPH POUNDS PER HOUR
PRESS PRESSURE
PRV PRESSURE REGULATING VALVE
PSI POUNDS PER SQUARE INCH
PSIA POUNDS PER SQUARE INCH ABSOLUTE
PSIG POUNDS PER SQUARE INCH GAUGE
QTY QUANTITY
RA RETURN AIR
RAD RADIATED
RD ROOF DRAIN
REFR REFRIGERANT
REQ REQUIRED
RH RELATIVE HUMIDITY
RLA RUNNING LOAD AMPS
RM ROOM
RND ROUND
RPM REVOLUTIONS PER MINUTE
SA SUPPLY AIR
SAN SANITARY
SEC'N SECTION
SEER SEASONAL ENERGY EFFICIENCY RATIO
SENS SENSIBLE
SF SQUARE FOOT
SH SENSIBLE HEAT
SHT SHEET
SND SOUND
SOL SOLENOID
SP STATIC PRESSURE
SPD STATIC PRESSURE DIFFERENTIAL
SPT STATIC PRESSURE TRANSMITTER
SQ SQUARE
SST STAINLESS STEEL
STL STEEL
STM STEAM
T&P TEMPERATURE AND PRESSURE
TC TEMPERATURE CONTROL
TD THERMODYNAMIC OR TEMPERATURE
DIFFERENTIAL (PER CONTEXT)
TDH TOTAL DYNAMIC HEAD
TEMP TEMPERATURE
TOT TOTAL
TPD TOTAL PRESSURE DROP
TSP TOTAL STATIC PRESSURE
TYP TYPICAL
UC UNDERCUT DOOR
UG UNDERGROUND
UNO UNLESS NOTED OTHERWISE
V VOLTS
VAC VACUUM
VD VOLUME DAMPER (MANUAL)
VEL VELOCITY
VERT VERTICAL
VFD VARIABLE FREQUENCY DRIVE
VOL VOLUME
VTR VENT THRU ROOF
W WATT OR WIDTH (PER CONTEXT)
W/ WITH
W/O WITHOUT
WB WET BULB
WC WATER COLUMN
WG WATER GAUGE
WPD WATER PRESSURE DIFFERENTIAL
WT WEIGHT
MECH MAIN GENERAL NOTES
1. ALL ELBOWS, FITTINGS, ETC., IN PIPING AND DUCTWORK REQUIRED
TO CLEAR ALL JOB OBSTRUCTIONS ARE NOT NECESSARILY
INDICATED. ALL NECESSARY TRANSITIONS, FITTINGS AND OFFSETS
ARE REQUIRED WHETHER SHOWN OR NOT.
2. BECAUSE OF THE LIMITED SPACE AVAILABLE TO INSTALL ALL OF THE
MECHANICAL WORK, COORDINATION BETWEEN THE VARIOUS
TRADES IS OF THE UTMOST IMPORTANCE. SEE SPECIFICATION
230100 FOR REQUIRED COORDINATION DRAWINGS.
3. THE CONTRACTOR SHALL COORDINATE STAGING AND SCHEDULING
WITH THE OWNER'S REPRESENTATIVE.
4. EXISTING CONDITIONS ARE BASED ON INFORMATION OBTAINED
FROM PREVIOUS CONSTRUCTION DOCUMENTS AND INFORMAL
FIELD OBSERVATION AND SHALL NOT BE CONSTITUTED AS "AS
BUILT." THE CONTRACTOR SHALL FIELD-VERIFY EXISTING
CONDITIONS BEFORE THE ONSET OF CONSTRUCTION.
5. DEMOLISH ALL PIPING, DUCTWORK EQUIPMENT, ETC., SHOWN TO BE
REMOVED, IN ITS ENTIRETY, INCLUDING ALL HANGERS AND
SUPPORTS.
6. WHERE CONTRACTOR IS REQUIRED TO CONCEAL NEW WORK,
REMOVE OR MODIFY EXISTING CONSTRUCTION OR EQUIPMENT, OR
ATTACH TO EXISTING CONSTRUCTION, THE CONTRACTOR SHALL
REPAIR OR REPLACE EXISTING CONSTRUCTION AND MATERIALS TO
MATCH CONDITIONS AT THE ONSET OF CONSTRUCTION. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO REMOVE AND REPLACE
EXISTING CEILINGS AND WALLS REQUIRED FOR INSTALLATION OF
MECHANICAL SYSTEMS.
7. THE OWNER SHALL MAINTAIN ALL SALVAGE RIGHTS OF EQUIPMENT
AND MATERIALS REMOVED. ALL EQUIPMENT AND MATERIALS NOT
CLAIMED BY THE OWNER SHALL BE REMOVED FROM THE PREMISES
BY THIS CONTRACTOR.
8. ALL WORK SHALL BE INSTALLED PER THE REFERENCE DETAILS,
REGARDLESS OF WHETHER OR NOT THE DETAILS ARE CALLED OUT
ON THE PLANS.
9. PROVIDE VENTS AT ALL HYDRONIC PIPING HIGH POINTS, AND
DRAINS AT ALL PIPING LOW POINTS, REGARDLESS OF WHETHER
SHOWN OR NOT.
10. THE CONTRACTOR SHALL VERIFY ALL REFRIGERANT PIPE SIZING
AND ROUTINGS WITH THE EQUIPMENT MANUFACTURER. THE
CONTRACTOR SHALL ALSO PROVIDE ALL REQUIRED REFRIGERANT
ACCESSORIES AS RECOMMENDED BY THE EQUIPMENT
MANUFACTURER FOR COMPLETE AND FULLY FUNCTIONAL SYSTEMS.
11. DO NOT SCALE THE LOCATION OF HVAC CEILING ELEMENTS, SUCH
AS AIR INLETS AND OUTLETS, FROM THE M-SERIES DRAWINGS. SEE
ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT HVAC
CEILING ELEMENT LOCATIONS. REFLECTED CEILING PLANS GOVERN
THE LOCATION OF DIFFUSERS, REGISTERS, AND GRILLES. M-SERIES
DRAWINGS GOVERN TYPE, STYLE, AND SIZE OF DIFFUSERS,
REGISTERS, AND GRILLES.
12. ALL DUCTWORK SHALL COMPLY WITH "HVAC DUCT CONSTRUCTION
STANDARDS - METAL AND FLEXIBLE," 3RD EDITION, SMACNA 2005,
EXCEPT WHERE MORE RESTRICTIVE REQUIREMENTS ARE
SPECIFIED. ANY PLAN REFERENCES TO "SMACNA FIGURE ---"
REFERS TO THIS STANDARD. SEE SPECIFICATIONS FOR SCHEDULE
OF DUCT PRESSURE CLASS AND SEAL CLASS.
13. IN GENERAL, THE FINAL FLEX DUCT RUNOUT TO EACH DIFFUSER,
REGISTER, OR GRILLE IS NOT SIZED ON PLANS. FLEX DUCT RUNOUT
SIZE SHALL MATCH AIR OUTLET NECK SIZE, UNO.
14. IT IS THE INTENT OF THESE DRAWINGS THAT A MANUAL BALANCING
DAMPER BE PROVIDED AT EVERY INDIVIDUAL DUCTED CONNECTION
TO AN AIR DEVICE, UNLESS A BALANCING DAMPER IS SCHEDULED
TO BE FURNISHED WITH AIR DEVICE.
15. ALL EXISTING TEMPERATURE CONTROLS THAT ARE BEING
DEMOLISHED OR DISABLED AS WORK OF THIS CONTRACT SHALL BE
COMPLETELY REMOVED FROM BUILDING.
16. THE CONTRACTOR SHALL CONNECT THE NEW HVAC SYSTEM TO THE
OWNER'S EXISTING BUILDING CONTROL SYSTEM. REFER TO THE
SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
17. CONTRACTOR SHALL HAVE THE DOCUMENTS REVIEWED
COMPLETELY BY A CERTIFIED BALANCING CONTRACTOR FOR THE
INCLUSION OF THE NECESSARY ADDITIONAL AIR AND HYDRONIC
SYSTEM BALANCING DEVICES NOT SHOWN IN THESE DOCUMENTS
FOR COMPLETE HVAC SYSTEM BALANCING. REFER TO
SPECIFICATION SECTION 230593 FOR CONSTRUCTION DOCUMENT
EXAMINATION REPORT.
18. THESE PLANS ARE DIAGRAMMATIC IN NATURE. THE CONTRACTOR
SHALL BE PREPARED TO MAKE SOME ALTERATIONS TO THE EXACT
LOCATION OF DUCTWORK, PIPING AND EQUIPMENT FROM THE
LOCATION INDICATED ON THESE DRAWINGS TO FIT ACTUAL JOB
CONDITIONS.
19. REMOVE CEILINGS AS REQUIRED TO COMPLETE THE SCOPE
INDICATED IN THE CONSTRUCTION DOCUMENTS. REPLACE OR
REINSTALL ALL PORTIONS OF THE BUILDING (CEILING TILES, WALLS,
ETC) REMOVED TO ACCOMMODATE THE INSTALLATION OF ANY
MECHANICAL DEVICE, EQUIPMENT, ETC., USING WORKERS
QUALIFIED IN THE APPROPRIATE TRADE. ALL SPACES ARE
REQUIRED TO REMAIN AVAILABLE DURING NORMAL BUSINESS
HOURS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENT
FULLY SPRINKLERED
Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
PROJECT MANAGEMENTCONSULTANT
321 4 5 6 7 8 9 10
6 S. OLD ORCHARD AVE.
WEBSTER GROVES, MO 63119
PHONE #: 314-918-8383
Consultant POC
8718 Botts Lane San Antonio, Texas 78217 www.hfscompany.com
Phone: (210) 816-4784 Fax: (210) 881-6808 jbianco@hfscompany.com
D U s e rs \j ru z ic k a
\D o c u m e n ts
\0
-M
E P
F P
-H O
S -R jR u z ic k a E
S P
H Z
.r v t
/2
/2
:2
:5
P
M
MH-000
MECHANICAL SYMBOLS AND
ABBREVIATIONS
EHRM INFRASTRUCTURE
UPGRADES - COLUMBIA, MO
800 HOSPITAL DR.
COLUMBIA, MO 65201
589A4-21-700
1/25/2022 MLW DBC
Revisions: Date:
4'-0"
11'-6"
T S R Q P Na N M L K Jb J Hb H G F EaMbNb FaSb
7.6
3.6
4.1
DN
UP
UP
UP
STAIR #1
UP
STR #3
CLEAN TUNNEL
C012
MH-400-1.PB
MH-400-1.PB
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENT
FULLY SPRINKLERED
Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
PROJECT MANAGEMENTCONSULTANT
321 4 5 6 7 8 9 10
6 S. OLD ORCHARD AVE.
WEBSTER GROVES, MO 63119
PHONE #: 314-918-8383
Consultant POC
KEY PLAN
8718 Botts Lane San Antonio, Texas 78217 www.hfscompany.com
Phone: (210) 816-4784 Fax: (210) 881-6808 jbianco@hfscompany.com
D U s e rs \j ru z ic k a
\D o c u m e n ts
\0
-M
E P
F P
-H O
S -R jR u z ic k a E
S P
H Z
.r v t
/2
/2
:2
:5
P
M
MH-100-1.PB
FLOOR PLAN - PARTIAL - PIPE
BASEMENT - AREA 3 & 4
EHRM INFRASTRUCTURE
UPGRADES - COLUMBIA, MO
800 HOSPITAL DR.
COLUMBIA, MO 65201
589A4-21-700
1/25/2022 MLW DBC
1/8" = 1'-0"
PIPE BASEMENT_PA_NW_MECH_AREA 3 & 4
GENERAL SHEET NOTES
1. ALL NEW PIPING PENETRATIONS THROUGH FLOORS OR ROOFS SHOULD
COORDINATE WITH STRUCTURAL. PROVIDE A SEAL AROUND NEW PENETRATION.
2. LOCATE BOTTOM OF ACUs APPROXIMATELY 1'-0" ABOVE CABLE TRAY.
COORDINATE FINAL ACU INSTALLATION HEIGHTS WITH OTHER TRADES.
3. REMOVE AND REINSTALL MECHANICAL EQUIPMENT, DUCTWORK, OR PIPING AS
REQUIRED FOR CABLE TRAY INSTALLATION. REINSTALL EQUIPMENT, DUCTWORK,
OR PIPING TO EXISTING OR BETTER CONDITIONS AS IT WAS BEFORE REMOVAL.
SEE TECHNOLOGY DRAWINGS FOR CABLE TRAY ROUTING.
PLAN NORTH
EXIST.
ELEV. LOBBY
CBE5
EXIST.
TELECOM
E006
C B
E
F023A CBF3
F024
F001A
F004
F021
F018
F020 F019 F017 F016
F015A
F015
F014
C B
F
F005 F010
F012
F013
F036F011
F009A
F009F008F007F006F003
CBF5
F001B
F001
F002A
F002
E012
E001G
CBF1
E001
E009
E010
E008
E007
CBE1CBE2
E004
E005
F037STR #11
E001A
E001CE001D
E001B
E002NE002M
E002O
E002F
E002E
E002D E002C E002Q
E002A
E002
E002B
F029A F029 F028
F027A
F028A F025
F025A
F027 F026
F034
F034A F035A
F035
F033F032F031F030
F030A
F023 F022
E003
CBE4
C B
F
-OPEN TO BELOW-
SEE PIPE BASEMENT FLOOR PLAN
DRAWING FOR ROOM DETAILS
DN
UP
UPDN
1 2 3 4 5 5.6 6.3 7 8 9 11 11.5 12
B
C
D
E
E.11211.51110.610
F
G
H
#10
#9
#11
F
F
F
F
F
F
F
MH-401-1.B
3/4" PC
DISCHARGE
DRAIN INTO
SERVICE SINK
MH-401-1.B
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENT
FULLY SPRINKLERED
Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
PROJECT MANAGEMENTCONSULTANT
321 4 5 6 7 8 9 10
6 S. OLD ORCHARD AVE.
WEBSTER GROVES, MO 63119
PHONE #: 314-918-8383
Consultant POC
KEY PLAN
8718 Botts Lane San Antonio, Texas 78217 www.hfscompany.com
Phone: (210) 816-4784 Fax: (210) 881-6808 jbianco@hfscompany.com
D U s e rs \j ru z ic k a
\D o c u m e n ts
\0
-M
E P
F P
-H O
S -R jR u z ic k a E
S P
H Z
.r v t
/2
/2
:2
:5
P
M
MH-101-1.B
FLOOR PLAN - PARTIAL -
BASEMENT - AREA 1
EHRM INFRASTRUCTURE
UPGRADES - COLUMBIA, MO
800 HOSPITAL DR.
COLUMBIA, MO 65201
589A4-21-700
1/25/2022 MLW DBC
1/8" = 1'-0"
BASEMENT_PA_NW_MECH_AREA 1
GENERAL SHEET NOTES
1. ALL NEW PIPING PENETRATIONS THROUGH FLOORS OR ROOFS SHOULD
COORDINATE WITH STRUCTURAL. PROVIDE A SEAL AROUND NEW PENETRATION.
2. LOCATE BOTTOM OF ACUs APPROXIMATELY 1'-0" ABOVE CABLE TRAY.
COORDINATE FINAL ACU INSTALLATION HEIGHTS WITH OTHER TRADES.
3. REMOVE AND REINSTALL MECHANICAL EQUIPMENT, DUCTWORK, OR PIPING AS
REQUIRED FOR CABLE TRAY INSTALLATION. REINSTALL EQUIPMENT, DUCTWORK,
OR PIPING TO EXISTING OR BETTER CONDITIONS AS IT WAS BEFORE REMOVAL.
SEE TECHNOLOGY DRAWINGS FOR CABLE TRAY ROUTING.
OFFICE
G051
EXIST.
TELECOM
G050
G014
CBG2
G001
C B
G
G012
G013
G048
G047
G043A
G052C
G045
G046
G043
G016 G052B
G052
G036
G032
G032A
G055
G059
G052A
G030
G029
G027A
G027
CBG6
G026
G015
G031 G024A G024B
G004
C B
G
G040A
G042
G023
G024 G018 G017
CBG4
G037
G040 G038
G019C G019A
G019B
G019
G008
G004A
G038A
G015A
STR #G1
-OPEN TO BELOW-
SEE PIPE BASEMENT
FLOOR PLAN
DRAWING FOR ROOM
DETAILS
UP
DN
DN
UU.5VWW.3W.4XYZAABBCCCC.6DD
3.6
4.1
4.5
4.7
6.1
7.1
7.6
8.3
8.9
9.8
10.2
6.3
#14
#15
#13 #12
3/4" PC
RS
RL
3/4" PC UP TO TELECOM ROOM G141 ACU-1-
G141. SEE SHEET MH-410-1.1 FOR
CONTINUATION.
MH-401-1.B
ROUTE CONDENSATE
DRAIN HIGH, DROP AT
COLUMN TO GRADE
LEVEL, AND ROUTE TO
EXISTING FLOOR DRAIN
DROP CONDENSATE
DRAIN AT MECHANICAL
ROOM WALL TO GRADE
LEVEL, AND ROUTE TO
EXISTING FLOOR DRAIN.
ROUTE REFRIGERANT PIPING UP SHAFT
TO CONDENSING UNIT ON ROOF. SEE
SHEET MH-111-1.1 FOR CONTINUATION.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENT
FULLY SPRINKLERED
Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
PROJECT MANAGEMENTCONSULTANT
321 4 5 6 7 8 9 10
6 S. OLD ORCHARD AVE.
WEBSTER GROVES, MO 63119
PHONE #: 314-918-8383
Consultant POC
KEY PLAN
8718 Botts Lane San Antonio, Texas 78217 www.hfscompany.com
Phone: (210) 816-4784 Fax: (210) 881-6808 jbianco@hfscompany.com
D U s e rs \j ru z ic k a
\D o c u m e n ts
\0
-M
E P
F P
-H O
S -R jR u z ic k a E
S P
H Z
.r v t
/2
/2
:2
:5
P
M
MH-102-1.B
FLOOR PLAN - PARTIAL -
BASEMENT - AREA 2
EHRM INFRASTRUCTURE
UPGRADES - COLUMBIA, MO
800 HOSPITAL DR.
COLUMBIA, MO 65201
589A4-21-700
1/25/2022 MLW DBC
1/8" = 1'-0"
BASEMENT_PA_NW_MECH_AREA 2
GENERAL SHEET NOTES
1. ALL NEW PIPING PENETRATIONS THROUGH FLOORS OR ROOFS SHOULD
COORDINATE WITH STRUCTURAL. PROVIDE A SEAL AROUND NEW PENETRATION.
2. LOCATE BOTTOM OF ACUs APPROXIMATELY 1'-0" ABOVE CABLE TRAY.
COORDINATE FINAL ACU INSTALLATION HEIGHTS WITH OTHER TRADES.
3. REMOVE AND REINSTALL MECHANICAL EQUIPMENT, DUCTWORK, OR PIPING AS
REQUIRED FOR CABLE TRAY INSTALLATION. REINSTALL EQUIPMENT, DUCTWORK,
OR PIPING TO EXISTING OR BETTER CONDITIONS AS IT WAS BEFORE REMOVAL.
SEE TECHNOLOGY DRAWINGS FOR CABLE TRAY ROUTING.
TELECOM
A056A
OFFICE
STORAGE
A060B
TELECOM
ROOM
A060
TELECOM
DEMARK ENTRANCE
A060A
7.2
6.3
5.5
4.6
4.4
3.7
2.8
1.9
A058
B007
B006B
B006A
A063C A063G
A063
A063A
A063H
A063D A063F
A024A
A056
STR #1
D007
D005AD005
D006
D004C
D004F
B050
C B
A
A055
A054B
A004
E001EE002H E002I E002J E002K E002L E001F
A001
A002
A003
CBA2
A007 A009
CBA3 CBA4
A005
A004A
A006 A008A A008
A012
A013
A010A
A010 A019 A020
A024
A024B
S T
R
A026
A027A
A027
A028
A022
A018
A025B A025
CBA5
A023 A029
A023A A031
C B
A
C B
A
A021
A045A
A015A
A015
A011
A014
A030
A032
A034
A033
A033
A035
A042A
A042A043A045A017
A033A
A033B
A038
A037
A036
A039A040A041
CBA8
A046
A047A
A047
CBA11
CBA8
D004L
A048
A049
A006A
A051
A51A
A050
CBA9
A052
CBA10
A053
A059A
A059
A057
D004M
D004N
D002
D001B
D001A
D001
D004E
D004B
D004AD004O
A009A
B001A
CBD1
A020A
A054
A016A
A016
A063EA063B
DN
UP
K J H G F E D C B AEaHbJb
A
Fa Eb Ab
1.1
#4
#5
#1#2#3
REX
MH-401-1.B
MH-401-1.B
3/4" PC UP, SEE SHEET
MH-410-1.1 FOR CONTINUATION
3/4" PC
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENT
FULLY SPRINKLERED
Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
PROJECT MANAGEMENTCONSULTANT
321 4 5 6 7 8 9 10
6 S. OLD ORCHARD AVE.
WEBSTER GROVES, MO 63119
PHONE #: 314-918-8383
Consultant POC
KEY PLAN
8718 Botts Lane San Antonio, Texas 78217 www.hfscompany.com
Phone: (210) 816-4784 Fax: (210) 881-6808 jbianco@hfscompany.com
D U s e rs \j ru z ic k a
\D o c u m e n ts
\0
-M
E P
F P
-H O
S -R jR u z ic k a E
S P
H Z
.r v t
/2
/2
:2
:0
P
M
MH-103-1.B
FLOOR PLAN - PARTIAL -
BASEMENT - AREA 3 & 4
EHRM INFRASTRUCTURE
UPGRADES - COLUMBIA, MO
800 HOSPITAL DR.
COLUMBIA, MO 65201
589A4-21-700
1/25/2022 MLW DBC
1/8" = 1'-0"
BASEMENT_PA_NW_MECH_AREA 3 & 4
GENERAL SHEET NOTES
1. ALL NEW PIPING PENETRATIONS THROUGH FLOORS OR ROOFS SHOULD
COORDINATE WITH STRUCTURAL. PROVIDE A SEAL AROUND NEW PENETRATION.
2. LOCATE BOTTOM OF ACUs APPROXIMATELY 1'-0" ABOVE CABLE TRAY.
COORDINATE FINAL ACU INSTALLATION HEIGHTS WITH OTHER TRADES.
3. REMOVE AND REINSTALL MECHANICAL EQUIPMENT, DUCTWORK, OR PIPING AS
REQUIRED FOR CABLE TRAY INSTALLATION. REINSTALL EQUIPMENT, DUCTWORK,
OR PIPING TO EXISTING OR BETTER CONDITIONS AS IT WAS BEFORE REMOVAL.
SEE TECHNOLOGY DRAWINGS FOR CABLE TRAY ROUTING.
KEYED NOTES
1. REMOVE ALL AIR DEVICES IN HARD CEILING TO BE DEMOLISHED WITHIN THIS
ROOM. PROVIDE TEMPORARY SUPPORTS AS REQUIRED TO CONTINUE
FUNCTION OF EXISTING MECHANICAL SYSTEMS DURING CONSTRUCTION.
REINSTALL ALL AIR DEVICES IN NEW CEILING.
M A
T C
H L
IN
E
'B
TU
W010
CBG2
10.4
11.5
12.5
13.5
10.2
13.4
EXIST.
TELECOM
W05B
N1
TO HOSPITAL
PALLETS WILL
BE STACKED
TWO HIGH ON
RACKS
ENGINEERING
ENV
P R
O C
E S
S S
T O
R E
S
TSS STORAGE
E Q
U
IP
M E
N T
SPS
T S
S
12111098
TSS STORAGE
TSS STORAGE
TSS STORAGE
75 64321
A
B
C
D
F
E
G
PS
PS
F
F
F
F
F
F
F
ROUTE RS/RL PIPING ALONG NORTH
WALL TO CONDENSING UNIT ON
LOADING DOCK ROOF. SEE SHEET
MH-170-1.R FOR CU LOCATION.
MH-401-1.B
RL
RS
MH-401-1.B
TERMINATE CONDENSATE
PIPING AT EXISTING
FUNNEL DRAIN
3/4" PC
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENT
FULLY SPRINKLERED
Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
PROJECT MANAGEMENTCONSULTANT
321 4 5 6 7 8 9 10
6 S. OLD ORCHARD AVE.
WEBSTER GROVES, MO 63119
PHONE #: 314-918-8383
Consultant POC
KEY PLAN
8718 Botts Lane San Antonio, Texas 78217 www.hfscompany.com
Phone: (210) 816-4784 Fax: (210) 881-6808 jbianco@hfscompany.com
D U s e rs \j ru z ic k a
\D o c u m e n ts
\0
-M
E P
F P
-H O
S -R jR u z ic k a E
S P
H Z
.r v t
/2
/2
:2
:0
P
M
MH-104-14.B
FLOOR PLAN - PARTIAL -
BASEMENT - WAREHOUSE
EHRM INFRASTRUCTURE
UPGRADES - COLUMBIA, MO
800 HOSPITAL DR.
COLUMBIA, MO 65201
589A4-21-700
1/25/2022 MLW DBC
1/8" = 1'-0"
BASEMENT_PA_NW_MECH_WAREHOUSE
GENERAL SHEET NOTES
1. ALL NEW PIPING PENETRATIONS THROUGH FLOORS OR ROOFS SHOULD
COORDINATE WITH STRUCTURAL. PROVIDE A SEAL AROUND NEW PENETRATION.
2. LOCATE BOTTOM OF ACUs APPROXIMATELY 1'-0" ABOVE CABLE TRAY.
COORDINATE FINAL ACU INSTALLATION HEIGHTS WITH OTHER TRADES.
3. REMOVE AND REINSTALL MECHANICAL EQUIPMENT, DUCTWORK, OR PIPING AS
REQUIRED FOR CABLE TRAY INSTALLATION. REINSTALL EQUIPMENT, DUCTWORK,
OR PIPING TO EXISTING OR BETTER CONDITIONS AS IT WAS BEFORE REMOVAL.
SEE TECHNOLOGY DRAWINGS FOR CABLE TRAY ROUTING.
C0K01
CORRIDOR
P-18
ELEV
K053
STAIR
K001
MECHANICAL
K005
LOADING
C0K03
CORRIDOR
K004
MED.
GAS
EQUIPMENT
ROOMK003
ELEC.
ROOM
K002
STORAGE
K006
STORAGE
K007
TELECOM
DEMARK
ENT. RM.
N.5
G.5
H
G
13121110
P
N
K
1.7
H.2
E.5
M
J
F
E
UP 24R
TERMINATE CONDENSATE AT
EXISTING FLOOR DRAIN
3/4" PC
MH-401-1.B
FD
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENT
FULLY SPRINKLERED
Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
PROJECT MANAGEMENTCONSULTANT
321 4 5 6 7 8 9 10
6 S. OLD ORCHARD AVE.
WEBSTER GROVES, MO 63119
PHONE #: 314-918-8383
Consultant POC
KEY PLAN
8718 Botts Lane San Antonio, Texas 78217 www.hfscompany.com
Phone: (210) 816-4784 Fax: (210) 881-6808 jbianco@hfscompany.com
D U s e rs \j ru z ic k a
\D o c u m e n ts
\0
-M
E P
F P
-H O
S -R jR u z ic k a E
S P
H Z
.r v t
/2
/2
:2
:0
P
M
MH-105-22.B
FLOOR PLAN - PARTIAL -
BASEMENT - CLC
EHRM INFRASTRUCTURE
UPGRADES - COLUMBIA, MO
800 HOSPITAL DR.
COLUMBIA, MO 65201
589A4-21-700
1/25/2022 MLW DBC
1/8" = 1'-0"
BASEMENT_PA_NW_MECH_CLC
GENERAL SHEET NOTES
1. ALL NEW PIPING PENETRATIONS THROUGH FLOORS OR ROOFS SHOULD
COORDINATE WITH STRUCTURAL. PROVIDE A SEAL AROUND NEW PENETRATION.
2. LOCATE BOTTOM OF ACUs APPROXIMATELY 1'-0" ABOVE CABLE TRAY.
COORDINATE FINAL ACU INSTALLATION HEIGHTS WITH OTHER TRADES.
3. REMOVE AND REINSTALL MECHANICAL EQUIPMENT, DUCTWORK, OR PIPING AS
REQUIRED FOR CABLE TRAY INSTALLATION. REINSTALL EQUIPMENT, DUCTWORK,
OR PIPING TO EXISTING OR BETTER CONDITIONS AS IT WAS BEFORE REMOVAL.
SEE TECHNOLOGY DRAWINGS FOR CABLE TRAY ROUTING.
E109 E110E125F
E125EC1E24
E125DE125CE125BE125A
E124
E123
E126
C
E
E133
E115
E114
E130
E131
E132
E112
E111
E129
E127
F100
E137
E102F E102E E102D E102C E102B E102A
F129
F135
F104
E-1204
F171
F128
F134
F122
C1E21
F171A
F150
F101
F125
C F
F123
F151B
F102
F126
C1F11
F124
F151A
C1F7
C1E12
E144
E140
F168
F137A
C1F7
F121
F137
F169
E146
E148
E138
C1E11
C1F1
C1F19
C
F
C1F2
C1F21
E147
C1E8 E145
E143
F136
F118
F117
F163
C1F20
F103
F160
F161
F116
C1F6
C F
F115
F164
F F
E134
C1E10
F166
F167
F165
F162
C
F
F109
F108
C1F8
F146
F131
C1F15
F105
F113
F114A
F127 F130
F103B
F114
F132
F151
F149
F119
F107
F106
F112 F155
F147
F152
C
F
C
F
F144
F138
F153
F138A
F145
F148
F110 F111 F142F141F140F139 F156
C1F12 C1F13
F133
F157 F158 F159
C1F17
F142 F154
F120
E127A
F103A
EXIST.
ELEV. LOBBY
C1E9
EXIST.
TELECOM
E139
#10
#9
#11
UP
E X
T
EXT30EXT36
E X
T
EXT30 EXT36
M V
M V
O
O
M A
M A
E.5
F.1
F.2
F.9
G.5
C
C.3
D
D.1
E
E.1
F
G
H
0 0.1 1 2 3 4 5 5.6 6 6.3 7 8 9
FE
FE
FE
FE
FE
FE
FE
FE
TV
T
VTV
3/4" PC
MH-410-1.1
TERMINATE PC
INTO SERVICE
SINK
MH-410-1.1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENT
FULLY SPRINKLERED
Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
PROJECT MANAGEMENTCONSULTANT
321 4 5 6 7 8 9 10
6 S. OLD ORCHARD AVE.
WEBSTER GROVES, MO 63119
PHONE #: 314-918-8383
Consultant POC
KEY PLAN
8718 Botts Lane San Antonio, Texas 78217 www.hfscompany.com
Phone: (210) 816-4784 Fax: (210) 881-6808 jbianco@hfscompany.com
D U s e rs \j ru z ic k a
\D o c u m e n ts
\0
-M
E P
F P
-H O
S -R jR u z ic k a E
S P
H Z
.r v t
/2
/2
:2
:0
P
M
MH-110-1.1
FLOOR PLAN - PARTIAL - FIRST
FLOOR - AREA 1
EHRM INFRASTRUCTURE
UPGRADES - COLUMBIA, MO
800 HOSPITAL DR.
COLUMBIA, MO 65201
589A4-21-700
1/25/2022 MLW DBC
1/8" = 1'-0"
1ST FLOOR_PA_NW_MECH_AREA 1
GENERAL SHEET NOTES
1. ALL NEW PIPING PENETRATIONS THROUGH FLOORS OR ROOFS SHOULD
COORDINATE WITH STRUCTURAL. PROVIDE A SEAL AROUND NEW PENETRATION.
2. LOCATE BOTTOM OF ACUs APPROXIMATELY 1'-0" ABOVE CABLE TRAY.
COORDINATE FINAL ACU INSTALLATION HEIGHTS WITH OTHER TRADES.
3. REMOVE AND REINSTALL MECHANICAL EQUIPMENT, DUCTWORK, OR PIPING AS
REQUIRED FOR CABLE TRAY INSTALLATION. REINSTALL EQUIPMENT, DUCTWORK,
OR PIPING TO EXISTING OR BETTER CONDITIONS AS IT WAS BEFORE REMOVAL.
SEE TECHNOLOGY DRAWINGS FOR CABLE TRAY ROUTING.
C133C
G
G176
G100
G101
G102
G102A
G160
G103
G
G105
G106
G
G105A
G108
G114A
G
G116
G114
G115
G113G112
G156
G173G
G111
G110
G110A
G
G148 G147 G146 G171
G145
G143A
G144
G142A
G168
G142
G170
G169
G143
G107
G136 G139
G155
G155B
G137
G138
G163 G162
G120
G121
G123
G122
G133
G127 G128
G159
G
G
G129
G130
G131
G132
G119
G124
G
G118 G161
G164A
G164
G135 G140
G
A
G193
G149
G150
G150A
G151 G153
B176D
G152
G196E
G196H G196G G196F
G192
EXIST.
TELECOM
G141
#14
#13 #12
#15
UU.5VWW.4XYZAABBCCCC.6DD
10.4
10.2
9.8
9.1
8.9
8.3
8.2
7.6
7.2
7.1
6.7
6.3
6.2
6.1
5.5
5.4
5.1
4.7
4.6
4.1
DD CC.6 CC BB AA
3.7
3.6
3.2
5.7
9*
N7
F
F
F F
F
F
F
10.2
8.9
XYZ
MH-410-1.1
MH-410-1.1
RS/RL UP TO 2ND FLOOR .
SEE VIEW "2" ON THIS
SHEET FOR CONTINUATION
RS/RL UP TO CONDENSING UNIT. SEE
SHEETS MH-101-1.B AND MH-401-1.B
FOR CONTINUATION. SEE SHEET
MH-170-1.R FOR CU LOCATION.
CU
1-G141 RL
RS
FIRST FLOOR
ROOF (OR)
INTERSTITIAL SPACE
ABOVE FIRST FLOOR
RS/RL DOWN TO FIRST FLOOR.
SEE VIEW "1" ON THIS SHEET
FOR CONTINUATION
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENT
FULLY SPRINKLERED
Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
PROJECT MANAGEMENTCONSULTANT
321 4 5 6 7 8 9 10
6 S. OLD ORCHARD AVE.
WEBSTER GROVES, MO 63119
PHONE #: 314-918-8383
Consultant POC
KEY PLAN
8718 Botts Lane San Antonio, Texas 78217 www.hfscompany.com
Phone: (210) 816-4784 Fax: (210) 881-6808 jbianco@hfscompany.com
D U s e rs \j ru z ic k a
\D o c u m e n ts
\0
-M
E P
F P
-H O
S -R jR u z ic k a E
S P
H Z
.r v t
/2
/2
:2
:1
P
M
MH-111-1.1
FLOOR PLAN - PARTIAL - FIRST
FLOOR - AREA 2
EHRM INFRASTRUCTURE
UPGRADES - COLUMBIA, MO
800 HOSPITAL DR.
COLUMBIA, MO 65201
589A4-21-700
1/25/2022 MLW DBC
1/8" = 1'-0"
1ST FLOOR_PA_NW_MECH_AREA 2
1/8" = 1'-0"
2ND FLOOR_PA_NW_MECH_INTERSTITIAL
GENERAL SHEET NOTES
1. ALL NEW PIPING PENETRATIONS THROUGH FLOORS OR ROOFS SHOULD
COORDINATE WITH STRUCTURAL. PROVIDE A SEAL AROUND NEW PENETRATION.
2. LOCATE BOTTOM OF ACUs APPROXIMATELY 1'-0" ABOVE CABLE TRAY.
COORDINATE FINAL ACU INSTALLATION HEIGHTS WITH OTHER TRADES.
3. REMOVE AND REINSTALL MECHANICAL EQUIPMENT, DUCTWORK, OR PIPING AS
REQUIRED FOR CABLE TRAY INSTALLATION. REINSTALL EQUIPMENT, DUCTWORK,
OR PIPING TO EXISTING OR BETTER CONDITIONS AS IT WAS BEFORE REMOVAL.
SEE TECHNOLOGY DRAWINGS FOR CABLE TRAY ROUTING.
01 1 A0 01
A158A160A161 A159
C168 C170 C171
C174
C175
C173
C172C167C146 C137C125C126C127C128
C136
C124
C123
C133
C134
C113
C111
C112
C114
C115
C116
C117
C118
C119
C132
C120 C121 C122
B168
B172
B176
B176C
B176B
B176A
B152
B148
B154 B167B
B160
B164
B166
B167A B167
B129
B128
B165
B136B
B136 B132
B136A
B175A
B112AB108
B108A
B107A
B107
B104 B105
B109 B110 B112
B135
B133
A103
B150
C1A8
A153
A152A
A191
A149
A148A187A188
C1A9
A167
C
A
A162
A165
A166
A168
A
C135
G194B
B106
B131A
B131B
B
B179
B126 B129
B174
C B
B119
B170
C169
C168 B121 B120 B122
C1B4
B127
B128
B130 B131 B164
B165
C
B
B123
C176
D149
D101
A189
A147
A106A107
A194
A110
A117G
A117F
A117E
A117A
A117B A116
A115
C
B
A116A
A153C
A117C
C1A7 A117D
A156C
A156B
A156A
A157
A101
A102A108A109A111A112A113A114
A153B
B149
A186
C1A2
A193 A192
D102H D102K
D104
D102L
D106
D130
D
A
D
D102A
D102B
D102C
D102D D120
D102G D103
E102LE102G
A163
B139
C1E14
E102J E102K
B146
E108B
E105
C1A1
E102H
E104
E107
E108
B139A
E102
E103
E108C
B145
B116
B116A
B138B134
B137
B132A
B166A
C
A
C
B
B152A
B173
A118
B134A
A172 A171 A169
B175
B160A
MATCH LINE 'A'
M A
T C
H L
IN
E
'B
MATCH LINE 'C'
M A
T C
H L
IN
E
'D
M A
T C
H L
IN
E
'B
EXIST.
TELECOM
A153A
BREAK
ROOM
B144
EXIST.
TELECOM
B144A
LOCKERS
B143
EXIST.
TOILET
B144B
ELECTRIC
SHAFT
D202A
#4
#5
#1#2#3
UPDN
UP
DN
UP
E X
T
E X
T
NG
NG
NG NG NG
NGNGNG
MV MV MV MV
MV
MV
MV
MV
O2 O2 O2 O2
O2
O2
O2
MA MA MA MA
MA
MA
MA MA MA MA
MAMAMAMA
MA
Sb Nb Mb Fa EbT S R Q P Na N M La L K Jb J Hb H Ga G F Ea
FE
S
S S
S S
S
S
T V
T V
REFG.
REFG.
MH-410-1.1
MH-410-1.1
MH-410-1.1
MH-410-1.1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENT
FULLY SPRINKLERED
Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
PROJECT MANAGEMENTCONSULTANT
321 4 5 6 7 8 9 10
6 S. OLD ORCHARD AVE.
WEBSTER GROVES, MO 63119
PHONE #: 314-918-8383
Consultant POC
KEY PLAN
8718 Botts Lane San Antonio, Texas 78217 www.hfscompany.com
Phone: (210) 816-4784 Fax: (210) 881-6808 jbianco@hfscompany.com
D U s e rs \j ru z ic k a
\D o c u m e n ts
\0
-M
E P
F P
-H O
S -R jR u z ic k a E
S P
H Z
.r v t
/2
/2
:2
:1
P
M
MH-112-1.1
FLOOR PLAN - PARTIAL - FIRST
FLOOR - AREA 3 & 4
EHRM INFRASTRUCTURE
UPGRADES - COLUMBIA, MO
800 HOSPITAL DR.
COLUMBIA, MO 65201
589A4-21-700
1/25/2022 MLW DBC
1/8" = 1'-0"
1ST FLOOR_PA_NW_MECH_AREA 3 & 4
GENERAL SHEET NOTES
1. ALL NEW PIPING PENETRATIONS THROUGH FLOORS OR ROOFS SHOULD
COORDINATE WITH STRUCTURAL. PROVIDE A SEAL AROUND NEW PENETRATION.
2. LOCATE BOTTOM OF ACUs APPROXIMATELY 1'-0" ABOVE CABLE TRAY.
COORDINATE FINAL ACU INSTALLATION HEIGHTS WITH OTHER TRADES.
3. REMOVE AND REINSTALL MECHANICAL EQUIPMENT, DUCTWORK, OR PIPING AS
REQUIRED FOR CABLE TRAY INSTALLATION. REINSTALL EQUIPMENT, DUCTWORK,
OR PIPING TO EXISTING OR BETTER CONDITIONS AS IT WAS BEFORE REMOVAL.
SEE TECHNOLOGY DRAWINGS FOR CABLE TRAY ROUTING.
5.4
4.4
D125
D107
D124
D124A
D126
D127
D128
D129D129B
D100A
C182 C103 C102C1C2
C192
C191
C189 C184
C188
C185
C187
C186
C193
C180
C181
D194
C107
C142AC142C140AC140C139C138
C137A
C135
C134B
C136
C
A
C133B C1C10
C132
C106
C109
C179
D198
D199C
D199B
D193A
D193
D
E
D199
D183 D182 D155
D181
D180
C1C23
D
A
D
C
C
D179
D
B
C
C
D194A D189D
D185
D
C
D186
D187
D194
D199A
D195A
C152
D195
C1D23
D191 D190 D189 D170
D134
D152
D159A
D159B
D159
D160
D161
D158
D157
C
D
D162
D156
D154 D153
D153A
D163
D175A
D175
D173 D174
D164
D165
D173A
D166D167D168
C1D21
D169
D172A
D172D171
D171A
C133
C104
C110
C1C1 D101B
D150
D151B
C143
C101
C
C
C101C
D129C
D151
D151C
C101D
C1D5
C198
C1C9
C D
D102F
D102E
C D
C1D4
C137
C144
C1C2
EXISTING
U/C WAITING
C178
EXIST.
TELECOM
C105
#6
UP
DNUP UPDN
UP
DN
DN
FaMbNb
13.4
EaFGGaHHaJJaKLLaMNNaPQRRaRbSSbT
RS/RL UP TO FIRST FLOOR
ROOF (1 SW). SEE SHEET
MH-170-1.R FOR CONDENSING
UNIT LOCATIONS
MH-410-1.1
MH-410-1.1
3/4" PC
MH-410-1.1
MH-410-1.1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENT
FULLY SPRINKLERED
Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
PROJECT MANAGEMENTCONSULTANT
321 4 5 6 7 8 9 10
6 S. OLD ORCHARD AVE.
WEBSTER GROVES, MO 63119
PHONE #: 314-918-8383
Consultant POC
KEY PLAN
8718 Botts Lane San Antonio, Texas 78217 www.hfscompany.com
Phone: (210) 816-4784 Fax: (210) 881-6808 jbianco@hfscompany.com
D U s e rs \j ru z ic k a
\D o c u m e n ts
\0
-M
E P
F P
-H O
S -R jR u z ic k a E
S P
H Z
.r v t
/2
/2
:2
:1
P
M
MH-113-1.1
FLOOR PLAN - PARTIAL - FIRST
FLOOR - AREA 3A & 4A
EHRM INFRASTRUCTURE
UPGRADES - COLUMBIA, MO
800 HOSPITAL DR.
COLUMBIA, MO 65201
589A4-21-700
1/25/2022 MLW DBC
1/8" = 1'-0"
1ST FLOOR_PA_NW_MECH_AREA 3A & 4A
GENERAL SHEET NOTES
1. ALL NEW PIPING PENETRATIONS THROUGH FLOORS OR ROOFS SHOULD
COORDINATE WITH STRUCTURAL. PROVIDE A SEAL AROUND NEW PENETRATION.
2. LOCATE BOTTOM OF ACUs APPROXIMATELY 1'-0" ABOVE CABLE TRAY.
COORDINATE FINAL ACU INSTALLATION HEIGHTS WITH OTHER TRADES.
3. REMOVE AND REINSTALL MECHANICAL EQUIPMENT, DUCTWORK, OR PIPING AS
REQUIRED FOR CABLE TRAY INSTALLATION. REINSTALL EQUIPMENT, DUCTWORK,
OR PIPING TO EXISTING OR BETTER CONDITIONS AS IT WAS BEFORE REMOVAL.
SEE TECHNOLOGY DRAWINGS FOR CABLE TRAY ROUTING.
11.5
13.5
13.6
12.5
C2E7
C2E12
F210 F211 F212 F214 F215 F217 F235 F236
F239 F240 F267 F266 F265
F269
C2F23
F268 F264 F263
F210A
C2F3
F204
C2F1
F201
F202
F206DF206C
C2F7
F203
E202
F224
C2F8
F206AF206B
F205
F242
F237
F206
F207
C2F20
E201
C2F20
F256
F245
F241
C 2F
F231
F223
C2F14 F257
F230
F232
F219
F238
F233
C2F16
F234
F243
F246
C 2F
E207
E204A
F209
C2F4
C2F6
F216
F208
C 2F
F209A
E204
C2E6
F247
F244
C2F17
F225
F228
E209
E205A C2E3
E222E223E225E226
F218
C2F12
F222
C 2E
E212A
E224A
E214
E213
E205
F221
C2F19
F227
F222A
E208
E217
E212E211
E
C 2E
C 2F
F250
F255
C 2F
F226
E216E255
C2E1 E253
E220
F211A
F248
F249
C 2F
F220
E211A
E254
E210
F256
C 2F
F213A
F213
E221
E219
E218
C 2F
E215
F252
F257
F260F271
F261F270
F262
C 2F
F258F273
F259F272
F229
F200
F274
E209A
F275
F213B
E241
E239
E237
E236
C2E9
C2E11
E230E232E233E234E235
E238 C2E16
C2E14
C 2E
E244
E240
E242 E243 E249
C2E18
E245
C 2E
E246
E247
E248 E250
E231
E228
C2E13
E251 E252
F251
F253
EXIST.
ELEV. LOBBY
C2E10
EXIST.
TELECOM
E203
#10
#9
#11
DN
UP
DN
2 3 4 5 6 7 8 9 10 11 11.6 12
H
G.5
G
F.2
F
E
D.8
D
C
B
5.6 6.3 10.6 11.5 12.1
F.9
F.1
E.4
E.1
D.5
F
F E
FE
F
F
F
F
F
T V
3/4" PC
MH-420-1.2
3/4" PC
DISCHARGE PC
INTO SERVICE
SINK
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENT
FULLY SPRINKLERED
Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
PROJECT MANAGEMENTCONSULTANT
321 4 5 6 7 8 9 10
6 S. OLD ORCHARD AVE.
WEBSTER GROVES, MO 63119
PHONE #: 314-918-8383
Consultant POC
KEY PLAN
8718 Botts Lane San Antonio, Texas 78217 www.hfscompany.com
Phone: (210) 816-4784 Fax: (210) 881-6808 jbianco@hfscompany.com
D U s e rs \j ru z ic k a
\D o c u m e n ts
\0
-M
E P
F P
-H O
S -R jR u z ic k a E
S P
H Z
.r v t
/2
/2
:2
:2
P
M
MH-120-1.2
FLOOR PLAN - PARTIAL - SECOND
FLOOR - AREA 1
EHRM INFRASTRUCTURE
UPGRADES - COLUMBIA, MO
800 HOSPITAL DR.
COLUMBIA, MO 65201
589A4-21-700
1/25/2022 MLW DBC
1/8" = 1'-0"
2ND FLOOR_PA_NW_MECH_AREA 1
GENERAL SHEET NOTES
1. ALL NEW PIPING PENETRATIONS THROUGH FLOORS OR ROOFS SHOULD
COORDINATE WITH STRUCTURAL. PROVIDE A SEAL AROUND NEW PENETRATION.
2. LOCATE BOTTOM OF ACUs APPROXIMATELY 1'-0" ABOVE CABLE TRAY.
COORDINATE FINAL ACU INSTALLATION HEIGHTS WITH OTHER TRADES.
3. REMOVE AND REINSTALL MECHANICAL EQUIPMENT, DUCTWORK, OR PIPING AS
REQUIRED FOR CABLE TRAY INSTALLATION. REINSTALL EQUIPMENT, DUCTWORK,
OR PIPING TO EXISTING OR BETTER CONDITIONS AS IT WAS BEFORE REMOVAL.
SEE TECHNOLOGY DRAWINGS FOR CABLE TRAY ROUTING.
D206A
C201C
C201B
D202
D202B
D212
D201
D206
D205A
D201A
D203
D204 D219C
D219B
D219
D220
D219H
D219G
D219F
D221
A223
A223A
A223C
A225A222A
A220
A226A205A207
A204
C2E8
C203
B236
B204
B238
B203
B239A
B239
B241
A212
B200
B242A201
A200
B237
D219E
C201
C201D
C202
C201F C201E
C201A
B201B A214 A215
A209
C2A05
C 2A
A202 A203 A218
D219D
A200A
A219
C2A03
A208
A216
A212
STR #1
C 2A
A222
A200
C2B4A
A201B C2A02
A200A
A206A
C2A01
A211
A213
A210
A223B
A223D
A221
C2A09
EXIST.
TELECOM
A217
#2#3 #1
#4
#5
UPDN
UP
OPEN TO
ROOF ACCESS
N7
N2
Na N M L K J H G FJb HbNb Ma Fa
3 2 1
6 5 4
0 #
3 2 1
6 5 4
0 #
BMS
BMS
ANT
T T B
AREA NOT IN SCOPE
PROJECT: 589A4-19-103
RELOCATE BEHAVIOR HEALTH CLINIC
CU
2-A217.1
CU
2-A217.2
CU
1-B144A
CU
3-A306A
CU
1-A153A
MH-420-1.2
MH-420-1.2
ROUTE REFRIGERANT PIPING UP ALONG EXTERIOR WALL
TO PENETRATE WALL ABOVE SECOND FLOOR CEILING
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENT
FULLY SPRINKLERED
Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
PROJECT MANAGEMENTCONSULTANT
321 4 5 6 7 8 9 10
6 S. OLD ORCHARD AVE.
WEBSTER GROVES, MO 63119
PHONE #: 314-918-8383
Consultant POC
KEY PLAN
8718 Botts Lane San Antonio, Texas 78217 www.hfscompany.com
Phone: (210) 816-4784 Fax: (210) 881-6808 jbianco@hfscompany.com
D U s e rs \j ru z ic k a
\D o c u m e n ts
\0
-M
E P
F P
-H O
S -R jR u z ic k a E
S P
H Z
.r v t
/2
/2
:2
:2
P
M
MH-121-1.2
FLOOR PLAN - PARTIAL - SECOND
FLOOR - AREA 4
EHRM INFRASTRUCTURE
UPGRADES - COLUMBIA, MO
800…