This document provides details for a federal contract opportunity to complete EHRM Infrastructure Upgrades Construction work. The solicitation number is 36C77622R0069 and is being issued by the Department of Veterans Affairs Technology Acquisition Center Austin. The contractor will be required to provide all labor, project management, materials, tools, supplies, and equipment as required by drawings and specifications to complete the necessary work for the EHRM Infrastructure Upgrades Construction project located in Columbia, MO. The related file referenced is the Final Drawings_Part2.pdf, but its content was not listed.
View the file
Other files
Show all 31
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SOUND ATTENUATION
BATT INSULATION
5/8" 3 5/8" 5/8"
CONTINUOUS FIRE-RATED
SEALANT EACH SIDE
6"
2"
SOUND ATTENUATION
BATT INSULATION
5/8" 3 5/8" 5/8"
6" TYP. (UNO)
2"
5/8" FIRE-RATED GYPSUM BOARD
ON 3 5/8" METAL STUDS
4", 6" OR 8" CMU LINTEL HEADER
CMU W. + 1"
2"
EX. CMU
3/ 8"
4", 6" OR 8" CMU JAMB WITH
MINIMUM 3 MASONRY TYPE
ANCHORS
CMU W. + 1"
2"
EX. CMU
3/ 8"
1 DOOR HEAD
SCALE: 3" = 1'-0" 6 DOOR HEAD
SCALE: 3" = 1'-0"
7 DOOR JAMB
SCALE: 3" = 1'-0"2 DOOR JAMB
SCALE: 3" = 1'-0"
DOOR/FRAME ASSEMBLY
AS SCHEDULED
CONTINUOUS FIRE-RATED
SEALANT EACH SIDE
5/8" FIRE-RATED GYPSUM BOARD
ON 3 5/8" METAL STUDS
GROUT FILL SOLID
CONTINUOUS FIRE-RATED
SEALANT EACH SIDE
CONTINUOUS FIRE-RATED
SEALANT EACH SIDE
DOOR/FRAME ASSEMBLY
AS SCHEDULED
DOOR/FRAME ASSEMBLY
AS SCHEDULED
DOOR/FRAME ASSEMBLY
AS SCHEDULED
GROUT FILL SOLID
3 DOOR SILL
SCALE: FULL SIZE
4 DOOR SILL
SCALE: FULL SIZE
1 3/4"
1 3/4"
DOOR AS
SCHEDULED
DOOR AS
SCHEDULED
EXISTING
FLOORING
FLOOR AS
SCHEDULED
ROPPE #159
'BLACK' (B.O.D.)
DETAIL 'A'
DETAIL 'B'
FLOOR AS
SCHEDULED
ROPPE #59
'BLACK' (B.O.D.)
EXISTING
FLOORING
DOOR AS
SCHEDULED
FLOOR AS
SCHEDULED
FLOOR AS
SCHEDULED
MARBLE
THRESHOLD
4" MAX.
5 DOOR SILL
SCALE: FULL SIZE
DOOR AS
SCHEDULED
SET UNIT IN
FULL BED OF
MASTIC
ALUMINUM
THRESHOLD
PER HARDWARE
SCHEDULE
5"
3 JAMB ANCHORS MIN.
11 1/2" 11 1/2"
5/
8"
2"
6' -4
/8
H x
4' -1
0"
W
M
AS
O N
R Y
O
PN
G
6' -0
" H . x
'-7
" W
W
IN
D O
W O
PN
G
12 EXISTING WINDOW OPENING ENCLOSURE
SCALE: 3" = 1'-0"
1 1/2" 10"10"
15/16"
13 ELECTRIC SHAFT GRATE
SCALE: 3" = 1'-0"
SEE PLAN (FIELD VERIFY)
15/16"
3/4"
1'-0" W. x 3'-0" L.
11 1/4"
8 FLOOR STEP @ A060
SCALE: 3" = 1'-0"
5"
1 1/2"
4' -6
3"
1' -0
3'
-6
1' -4
10 RAISED FLOOR GUARDRAIL
SCALE: 3" = 1'-0"
26 WALL PROTECTION AT CBE5
27 WALL PROTECTION AT C1E9 & C2E10
28 WALL PROTECTION AT G191
29 WALL PROTECTION AT G191
30 WALL PROTECTION AT C176 & C178
PLASTIC
LAMINATE AT
TREAD AND
RISER
1" ALUMINUM
ANGLE AT
PERIMETER
2X WOOD
BLOCKING
3/4" 'AC' FACE
PLYWOOD
1 1/2" ROUND MILL
FINISH ALUMINUM
HORIZONTAL RAIL
1 1/2" SQUARE MILL
FINISH ALUMINUM
VERTICAL POST
(MIN. 3 EQUALLY
SPACED)
ALUMINUM BREAK
METAL TRIM
2"
4"
ALUMINUM BREAK
METAL TRIM
EXISTING RAISED
FLOOR SYSTEM AS
INDICATED BY
HATCH
2 X 4 WOOD NAILERS
BETWEEN FLOOR
SUPPORTS
ALUMINUM ANCHOR
PLATE AT EACH
VERTICAL POSTS
EXISTING MODULAR BRICK
VENEER WITH CMU
BACK-UP
EXISTING STEEL ANGLE
LINTELS
DEMOLITION RENOVATION
REMOVE EXISTING
CEILING ASSEMBLY AND
WOOD BLOCKING (AS
INDICATED BY HATCH)
REMOVE EXISTING
WINDOW ASSEMBLY
COMPLETE
REMOVE EXISTING SILL
PLASTER AND WOOD
BLOCKING (AS INDICATED
BY HATCH)
REMOVE EXISTING
HEATER UNIT
EXISTING PLASTER ON
FURRING CHANNELS
BACKER ROD AND
SEALANT AS INDICATED
MODULAR BRICK
TO MATCH EXISTING
(TOOTH-IN)
RIGID INSULATION
BOARD (MIN. 12.5
R-VALUE)
W/FULLY SEALED
JOINTS
4" CMU INFILL -
FULLY DAMPROOFED
MIN. 3/4" PLASTER
OVER METAL LATH
ON 7/8" FURRING
CHANNELS
ADJUSTABLE
MASONRY ANCHOR
EXISTING PLASTER AT
JAMBS TO REMAIN
MIN. STL. L4x3x1/4"
W/ANCHOR BOLTS
@ 18" O.C. MAX.
(EA. SIDE AS
SHOWN)
EXISTING CMU
WALL EXISTING DOOR
SILL CAN REMAIN
GALVANIZED STEEL
GRATE (McNICHOLS
GW-200 B.O.D.)
EQ
U
AL
EQ
U
AL
6"
NOTE: FIELD CUT GRATE CONDUIT
OPENINGS.
22 EXISTING WALL PANEL @ C1E9 & C2E10
23 EXISTING WALL PANEL @ C1E9 & C2E10
AS-710
DOOR & MISCELLANEOUS DETAILS
IAR
IAR, JFB
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
589A4-21-700
1/25/2022
100% CONSTRUCTION
DOCUMENT
EHRM Infrastructure Upgrades - Columbia, MO
800 HOSPITAL DRIVE
COLUMBIA, MO 65201
ETS
T
TA
GE
S
R I
E T E X
FO
T
CE
TI
H
AS
DER CRA
F. BIAN
C
OJ
O
SE
P
H
7 6 22 1
1/25/2022 8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
3 5/8" STUD (NON-RATED)
4 7/8"+
3 5/8" STUD (1-HR FIRE-RATED, UL NO 465)
CONTINUOUS METAL
TRACK
CONTINUOUS FIRE RATED
SEALANT (ACOUSTICAL
SEALANT AT 1A)
3 5/8" 22 GAGE METAL
STUD FRAMING AT 16" O.C.
SOUND ATTENUATION
BATT INSULATION
LINE OF STRUCTURE
DECK UNDERSIDE
CONTINUOUS FIRE RATED
SEALANT BOTH SIDES (ACOUSTICAL
SEALANT AT 1A)
3 5/8" STUD (NON-RATED)
4 7/8"+
CONTINUOUS METAL
DEFLECTION TRACK
CEILING AS SCHEDULED
BASE AS
SCHEDULED
5/8" FIRE RATED GYPSUM BOARD
BOTH SIDES TO STRUCTURE
DECK UNDERSIDE (PROVIDE
REGULAR GYPSUM BOARD
AT 1A)
WAINSCOT (AS SCHEDULED)
EXISTING METAL STUD
FRAMED WALL W/ FIRE RATED
GYPSUM BOARD TO FULL
HEIGHT EACH SIDE (ACOUSTICAL
SEALANT AT 3A)
3 5/8" STUD (EXISTING PRESUMED 1 HR.)
4 7/8"±
FINISH W/5/8" FIRE RATED GYPSUM
BOARD BOTH SIDES TO STRUCTURE
DECK UNDERSIDE (WHERE REQUIRED)
1 PARTITION TYPES
SCALE: NTS
1A
2 3
CONTINUOUS METAL
TRACK
SOUND ATTENUATION
BATT INSULATION
LINE OF STRUCTURE
DECK UNDERSIDE
CONTINUOUS METAL
DEFLECTION TRACK
BASE AS
SCHEDULED
CONTINUOUS ACOUSTICAL
SEALANT
3 5/8" 22 GAGE METAL
STUD FRAMING AT 16" O.C.
5/8" GYPSUM BOARD
BOTH SIDES TO STRUCTURE
DECK UNDERSIDE
CEILING AS SCHEDULED
CONTINUOUS ACOUSTICAL
SEALANT BOTH SIDES
LINE OF STRUCTURE
DECK UNDERSIDE
CONTINUOUS FIRE RATED
SEALANT BOTH SIDES (TOP AND
BOTTOM OF WALL) ACOUSTICAL
SEALANT AT 3A
BASE AS
SCHEDULED
3 5/8" STUD (EXISTING NON-RATED)3A
4" CMU (EXISTING PRESUMED 1 HR.)
3 5/8"
LINE OF STRUCTURE
DECK UNDERSIDE
CONTINUOUS FIRE RATED
SEALANT BOTH SIDES (TOP AND
BOTTOM OF WALL)
BASE AS
SCHEDULED
EXISTING CMU WALL EXISTING METAL STUD
FRAMED WALL W/ FIRE RATED
GYPSUM BOARD (2 LAYERS)
3 5/8" STUD (EXISTING PRESUMED 2 HR.)
6 1/8"±
LINE OF STRUCTURE
DECK UNDERSIDE
CONTINUOUS FIRE RATED
SEALANT BOTH SIDES (TOP AND
BOTTOM OF WALL)
BASE AS
SCHEDULED
EXISTING METAL STUD
FRAMED WALL W/ FIRE RATED
GYPSUM BOARD (2 LAYERS)
3 5/8" STUD (EXISTING NON-RATED)
4 1/4"±
LINE OF STRUCTURE
DECK UNDERSIDE
CONTINUOUS SEALANT BOTH
SIDES (TOP AND BOTTOM OF
WALL)
BASE AS
SCHEDULED
AS-720
PARTITION TYPES
IAR
IAR, JFB
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
589A4-21-700
1/25/2022
100% CONSTRUCTION
DOCUMENT
EHRM Infrastructure Upgrades - Columbia, MO
800 HOSPITAL DRIVE
COLUMBIA, MO 65201
ETS
T
TA
GE
S
R I
E T E X
FO
T
CE
TI
H
AS
DER CRA
F. BIAN
C
OJ
O
SE
P
H
7 6 22 1
1/25/2022 8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
AC ABOVE COUNTER
A.F.F. ABOVE FINISHED FLOOR
A.F.G. ABOVE FINISHED GRADE
AER AERIAL
A.W.G. AMERICAN WIRE GAUGE
CC CONTRACTOR FURNISHED AND INSTALLED
CER CABLE ENTRANCE ROOM (ER NOT USED IN HEALTHCARE)
CLG ABOVE CEILING
CMP COMMUNICATIONS MULTIPURPOSE CABLE, PLENUM
CMR COMMUNICATIONS MULTIPURPOSE CABLE, RISER
C.O.R. CONTRACT OFFICER REPRESENTATIVE
DEMARC DEMARCATION POINT
DEMO DEMOLITION
DIAG DIAGRAM
DISTR DISTRIBUTION
(E) EXISTING
EMT ELECTRIC METAL TUBING
ELEC ELECTRIC OR ELECTRICAL
ELEV ELEVATION
EMER EMERGENCY
F.O.C. FIBER OPTIC CABLE
GFE GOVERNMENT FURNISHED EQUIPMENT
GFCI GOVERNMENT FURNISHED, CONTRACTOR INSTALLED (VC)
GFGI GOVERNMENT FURNISHED AND INSTALLED (VV)
GIP GALVANIZED IRON PIPE
GTB GROUND TERMINAL BOX
HE HEAD-END (PA, INTERCOM)
HDPE HIGH DENSITY POLYETHYLENE
IMC INTERMEDIATE METAL CONDUIT
ISP INSIDE CABLE PLANT
IDF INTERMEDIATE DISTRIBUTION FRAME (NOT USED)
-BOX JUNCTION BOX
MDF MAIN DISTRIBUTION FRAME (NOT USED)
MH MAINTENANCE HOLE (FORMERLY MANHOLE)
MM MULTI MODE
N/A NOT APPLICABLE
NEC NATIONAL ELECTRICAL CODE
N NEUTRAL
N.I.C. NOT IN CONTRACT
N.T.S. NOT TO SCALE
OFCP OPTICAL FIBER CONDUCTIVE, PLENUM
OFCR OPTICAL FIBER CONDUCTIVE, RISER
OFNP OPTICAL FIBER NONCONDUCTIVE, PLENUM
OFNR OPTICAL FIBER NONCONDUCTIVE, RISER
OSP OUTSIDE CABLE PLANT
PB PULL BOX
PR PAIR
PVC POLYVINYL CHLORIDE
RSC RIGID STEEL CONDUIT
SM SINGLE MODE
SP SERVICE PROVIDER
STD STANDARD
STP SHIELDED TWISTED PAIR
TB TERMINAL BLOCK
TR TELECOMMUNICATIONS ROOM
TYP TYPICAL
TZ TELECOMMUNICATIONS ZONE
UG UNDERGROUND
UGC UNDERGROUND COMMUNICATIONS CABLE
UON UNLESS OTHERWISE NOTED
UTP UNSHIELDED TWISTED PAIR
VC GOVERNMENT FURNISHED, CONTRACTOR INSTALLED (GFCI)
VV GOVERNMENT FURNISHED AND INSTALLED (GFGI)
WP WEATHERPROOF
1. GENERAL CONSTRUCTION
1.1. DEMOLITION
1.1.1. THE CONTRACTOR SHALL COORDINATE WITH THE C.O.R. TO MAKE SAFE ALL
THAT WILL NOT BE REMOVED DURING DEMOLITION.
1.1.2. EXISTING CABLES, MODULAR JACKS, FACEPLATES, AND PATCH CABLES MAY
NOT BE REMOVED UNTIL AFTER CUT-OVER TO THE NEW CABLE SYSTEM IS
COMPLETE. CUT-OVER MAY BE BY ZONE, FLOOR, BUILDING, ETC. AND SHALL BE
COORDINATED WITH THE C.O.R. PRIOR TO WORK BEING PERFORMED.
1.1.3. EXISTING PATCH PANELS, PATCH CABLES, EQUIPMENT RACKS, ETC., MAY BE
"FLOATED" DURING CONSTRUCTION AND REMOVED AFTER CUT-OVER IS
COMPLETE.
1.2. CONSTRUCTION
1.1.1. CONTRACTOR SHALL INSTALL AND "BUILD-OUT" TR EQUIPMENT RACKS, CABLE
TRAYS, AND FITTINGS TO THE EXTENT POSSIBLE. FINAL INSTALLATION MAY NOT
BE COMPLETE UNTIL AFTER FINAL CUT-OVER OF THE CONSTRUCTION AREA IS
COMPLETE.
1.1.2. INSTALL FIBER OPTIC BACKBONE RISER CABLES TO THE TR(S) IN
CONSTRUCTION AREA.
1.1.3. INSTALL HORIZONTAL CATEGORY 6A CABLES FROM WORK AREAS TO THE TR(S)
IN THE CONSTRUCTION AREA.
1.1.4. CONTRACTOR SHALL TEST AND CERTIFY 100% OF INSTALLED HORIZONTAL
CABLES.
2. DATA CENTER CONSTRUCTION
2.1. DEMOLITION
2.1.1. REMOVAL OF EXISTING CABINETS AND ABANDONED CABLING WILL FOLLOW
CUT-OVER TO NEW CABLE SYSTEMS AND RELOCATION OF EQUIPMENTS TO NEW
CABINETS.
2.1.2. CONTRACTOR WILL REMOVE "OLD CABINETS" AS THEY ARE EMPTIED.
2.1.3. "OLD" CABINETS WILL BE MOVED TO A STAGING AREA FOR DISPOSAL. THE
CONTRACTOR SHALL COORDINATE WITH THE C.O.R. PRIOR TO BEGINNING
WORK.
2.2. CONSTRUCTION
2.2.1. CONTRACTOR SHALL INSTALL CABINETS, EQUIPMENT RACKS, CABLE TRAYS
AND FITTINGS.
2.2.2. CONTRACTOR SHALL INSTALL BACKBONE CABLES FROM THE TR(S).
2.2.3. CONTRACTOR SHALL TEST AND CERTIFY 100% OF BACKBONE CABLE.
2.2.4. CONTRACTOR SHALL PROVIDE FIBER OPTIC PATCH CABLES PRIOR TO MOVING
EQUIPMENT TO NEW CABINETS.
3. CLOSEOUT (COMMISSIONING)
3.0.1. CONTRACTOR SHALL PERFORM TESTING AND CERTIFICATION IN ACCORDANCE
WITH SPECIFICATION 27 08 00.
3.0.2. CONTRACTOR SHALL PROVIDE TEST DOCUMENTATION AND AS-BUILT DRAWINGS
AS SPECIFIED.
1. THE CONTRACTOR SHALL REVIEW ALL CONTRACT DOCUMENTS INCLUDING THE DRAWINGS AND SPECIFICATIONS.
2. THE CONTRACTOR SHALL COMPLETE ALL WORK INCLUDED IN THE CONTRACT DOCUMENTS.
3. THE CONTRACTOR SHALL PHYSICALLY SURVEY AND VERIFY EXISTING CONDITIONS PRIOR TO STARTING CONSTRUCTION TO MINIMIZE UNFORESEEN CONDITIONS.
4. THE SCALE OF DRAWINGS IS PROVIDED AS A REFERENCE. THE CONTRACTOR IS RESPONSIBLE FOR CABLE LENGTHS, PATHWAY SIZING, DIMENSIONS, MEASUREMENTS, QUANTITIES, ETC.
5. THE CONTRACTOR SHALL COORDINATE AND VERIFY ALL ITEMS OF CASEWORK, CEILINGS, AND MILLWORK.
6. CONDUIT, CABLE TRAY, J-HOOKS, AND OTHER CABLE SUPPORTS ARE SHOWN IN APPROXIMATE LOCATIONS. CONTRACTOR SHALL COORDINATE WITH OTHER TRADES PRIOR TO INSTALLATION.
7. DISCREPANCIES OR CONFLICTS BETWEEN DRAWINGS AND SPECIFICATIONS SHALL BE CALLED TO THE ATTENTION OF THE DESIGN TEAM. DISCREPANCIES OR CONFLICTS BETWEEN THE DRAWINGS AND SPECIFICATIONS NOT CALLED TO THE ATTENTION OF THE DESIGN TEAM SHALL BE DEEMED TO HAVE BEEN RESOLVED WITHIN THE BID OR PROPOSAL AND THE CONTRACTOR SHALL PERFORM THE WORK IN THE IN THE MANNER, GREATER QUANTITY, BETTER QUALITY, IN ACCORDANCE WITH THE DESIGN TEAM'S INTERPRETATION.
GENERAL NOTES
TELECOMMUNICATION - GENERAL INFORMATION
ABBREVATIONS PHASING PLAN
LEGEND
T-001
TELECOMMUNICATIONS
GENERAL INFORMATION
RMJr
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
589A4-21-700
1/25/2022
100% CONSTRUCTION
DOCUMENT
EHRM Infrastructure Upgrades - Columbia, MO
800 HOSPITAL DRIVE
COLUMBIA, MO 65201
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
DATA OUTLET; LETTER INDICATES AS FOLLOWS:
N = JACK QUANTITY
COMBINED VOICE&DATA OUTLET; LETTER INDICATES AS FOLLOWS:
N = JACK QUANTITY
FLOOR BOX - OVER-COUNTER; LETTER INDICATES AS FOLLOWS:
N = JACK QUANTITY
DATA OUTLET - CEILING MOUNTED; LETTER INDICATES AS FOLLOWS:
N = JACK QUANTITY
WIRELESS ACCESS POINT
EZ PATH FIRESTOP PENETRATION
ELECTRICAL PANEL BOARD.
TMGB - TELECOM MAIN GROUND BUS BAR
BASKET CABLE TRAY
NURSE'S CALL MASTER STATION MTD ON NURSE'S COUNTER TOP
NURSE CALL TERMINAL CABINET
NURSE CALL STATION.
2= DUPLICATE FACILITIES FOR TWO BEDS.
D= DUTY STATION.
E= MTD 6'-0" AFF FOR SHOWER LOCATION, MTD 4'-6" AFF FOR TUB LOCATION,
MTD 3'-0" AFF FOR TOILET LOCATION.
P= PSYCHIATRIC CORRIDOR STATION WITH KEY SWITCH.
S= AUDIO VISUAL MALL STATION MTD 5'-0" AFF UNLESS OTHERWISE NOTED.
U= UTILITY CALL STATION, MTD 5'-0" AFF UNLESS OTHERWISE NOTED.
NURSE CALL STATION.
2= NURSE'S CALL DOME LIGHT. MTD 6" ABOVE DOOR.
D= CORRIDOR DOME LIGHT.
I= AUXILIARY INTERSECTIONAL DOME LIGHT.
TELEPHONE TERMINAL CABINET
TELEPHONE BACKBOARD (WALL MOUNTED)
N
N
N
N
25-JAN-22
RESPONSIBILITY MATRIX CF/CI -
DIV 27/28
CF/CI -
DIV 26 GFE/CI GF/GI GO/GRI GC
CATV N/A
Intercom System N/A Neutral Host - Distributed Antenna System Antennas (DAS) N/A Nurse Call System N/A Neon Coding N/A Patient Wandering System Devices N/A Public Address/Overhead Paging Speakers N/A Physical Security - Acess Controls (EXISTING) X Physical Security - Acess Controls (NEW) X RTLS (CenTraK) N/A Telecommunications Infrastructure Plant (TIP) X Telecom Room Equipment Fittings X Telecom Room Electrical & Lighting X Telecommunications Equipment Backboard - fire retardant plywood, fire retardant paint X
Telecommunications Pathway - cable tray, conduits, bushings, back-boxes, fittings X
Telecommunications Room Equipment Bonding X Telecommunications Grounding & Bonding - bus bars, ground conductor, backbone conductor X
TV Monitors N/A Video Surveillance Cameras N/A Wireless Network - VA Internal WLAN (WAPs) X Wireless Network - Patient Network WLAN (WAPs) X
* GC = General Contractor Furnished/General Contractor Installed
* CF/CI = Contractor Furnished/Contractor Installed
* GFE/CI = Government Furnished Equipment/Contractor Installed
* GF/GI = Government Furnished/Government Installed
* GO/GRI = Government Owned (Existing)/Government Removed and Installed
* X = Responsible
* NIC = Not In Contract
* N/A = Not Applicable to this scope of work or no systems currently installed.
PREFERRED PRODUCTS MATRIX
LINE DESCRIPTION MANUFACTURE PART NUMBER LINE DESCRIPTION MANUFACTURE PART NUMBER
01 Copper Connectivity 47 Cable support, steel, J-hook, 2"x3", integrated retainer clip, galvanzied MonoSystems H-233-S 02 Cable, UTP, CMP, Category 6, 4-pair, white Panduit PUP6504WH-UY 48 Center hanger bracket, steel, galvanized MonoSystems H-433-H 03 Cable, UTP, CMP, Category 6A, 4-pair, green Panduit PUP6AS04GR-G 49 Cable tray, "J-Tray", solid aluminum, 2-7/8"x 1-7/8"x10' MonoSystems H-433-AB 04 Cable, UTP, CMP, Category 6A, 4-pair, orange Panduit PUP6AS04OR-G 50 Cover, "J-Tray", solid aluminum MonoSystems H-433-AC 05 Cable, UTP, CMP, Category 6A, 4-pair, blue Panduit PUP6AS04BU-G 51 Threaded rod, 3/8"x6' Chatsworth 11440-001 06 Cable, UTP, CMP, Category 6A, 4-pair, pink CommScope UN874040614/10 52 Grounding & Bonding 07 Patch cable, UTP, CMP, Category 6, 4-pair, white, 6 ft. Panduit UTPSP6Y 53 Ground bus bar, TMGB, 2"x20" Chatsworth 40153-020 08 Patch cable, UTP, CMP, Category 6A, 4-pair, green, 6 ft. Panduit UTP6ASD6GR 54 Ground bus bar, TGB, 2"x12" Chatsworth 13622-212 09 Patch cable, UTP, CMP, Category 6A, 4-pair, orange, 6 ft. Panduit UTP6ASD6OR 55 Ground terminal block, 1-mounting hole Chatsworth 08009-001 10 Patch cable, UTP, CMP, Category 6A, 4-pair, blue, 6 ft. Panduit UTP6ASD6BU 56 Ground lug connector, compression type, #6 gauge Burndy YGA6C2TC38E2G1
11 Patch cable, UTP, CMP, Category 6, 4-pair, white, 10 ft. Panduit UTPSP10Y 57 Copper-to-Copper Antioxidant Joint Compound Chatsworth 40168-801 12 Patch cable, UTP, CMP, Category 6A, 4-pair, green, 10 ft. Panduit UTP6A10GR 58 Ground lug connector, compression type, #6 gauge Burndy YGA6C2TC38E2G1
13 Patch cable, UTP, CMP, Category 6A, 4-pair, orange, 10 ft. Panduit UTP6ASD10OR 59 Copper-to-Copper Antioxidant Joint Compound Chatsworth 40168-801 14 Patch cable, UTP, CMP, Category 6A, 4-pair, blue, 10 ft. Panduit UTP6ASD10BU 60 Telecom Room Fittings 15 Modular jack, Category 6, Mini-Com, 8P/8C, white Panduit CJ688TGWH 61 Equipment rack, Mighty Mo 20® Channel Racks, black Legrand OR-MM20730-B 16 Modular jack, Category 6A, Mini-Com, 8P/8C, green Panduit CJ6X88TGGR 62 Rack installation kit, concrete, 1/2" Chatsworth 40604-003 17 Modular jack, Category 6A, Mini-Com, 8P/8C, orange Panduit CJ6X88TGOR 63 Mounting plate, rack to runway, with bracket, 15-18", black Chatsworth 12730-718 18 Modular jack, Category 6A, Mini-Com, 8P/8C, blue Panduit CJ6X88TGBU 64 Cable runway, UL Classified, 18", 1-1/2"x3/8" stringers, black Chatsworth 11275-718 19 Modular jack, Category 6A, Mini-Com, 8P/8C, black Panduit CJ6X88TGBL 65 Cable runway, E-Bend, 18", 1-1/2"x3/8" stringers, black Chatsworth 10822-718 20 Modular jack, Category 6A, Mini-Com, 8P/8C, red Panduit CJ6X88TGRD 66 Radius drop, cross member Chatsworth 14304-718 21 Faceplate, wall phone, Category 6, stainless steel, 1-P, 1-gang Panduit KWP6PYY 67 Cross member, movable, 18", black Chatsworth 12115-718 22 Faceplate, Mini-Com, white, 1-P, 1-gang Panduit CFPL1WHY 68 Butt splice, UL Classified, 1-1/2"x3/8" stringer, black Chatsworth 16301-701 23 Faceplate, Mini-Com, white, 4-P, 1-gang Panduit CFPL4WHY 69 Junction splice, UL Classified, 1-1/2"x3/8" stringer, black Chatsworth 16302-701 24 Faceplate, Mini-Com, stainless steel, 8-P, 2-gang Panduit CFPL6S-2GY 70 Butt swivel splice, UL Classified, 1-1/2"x3/8" stringer, black Chatsworth 16487-701 25 Surface mount box, Mini-Com, white, 2-P Panduit CBX2WH-AY 71 Junction swivel splice, UL Classified, 1-1/2"x3/8" stringer, black Chatsworth 16488-701 26 Patch panel, angled, modular jack, with strian relief bar, 24-P, 1U Panduit CPPLA24WBLY 72 Vertical swivel splice, UL Classified, 1-1/2"x3/8" stringer, black Chatsworth 16489-701 27 Patch panel, angled, high density, modular jack, 48-P, 1U Panduit CPPA48HDWBLY 73 Triangular support bracket, aluminum Chatsworth 11312-718 28 Fiber Optic Connectivity 74 Threaded ceiling kit, 3/8" rod Chatsworth 11310-001 29 Cable, fiber optic, interlocking armor, OFCP, 9/125, SM OS2, 12-strand, yellow, pre-term 12F MPO * Leviton FT-AK012KK999F36C36CY-NNAS 75 Network cabinet, Gen 3 cabinet, 45U x 40" x 43.3", perf. 2-door front/rear, sq. punch rails, glacier white Chatsworth NF8N-113N-C42-1
30 Cable, fiber optic, interlocking armor, OFCP, 50/125, MM OM4, 24-strand, aqua, pre-term 12F MPO * Leviton FT-FK024KK999F36C36CY-NNAS
76 Server cabinet, Gen 3 cabinet, 45U x 23.6" x 43.3", perf. dbl-door front/rear, sq. punch rails, glacier white Chatsworth FF1N-113C-E42-B
31 Patch cable, fiber optic, OFNP, 9/125, SM OS-2, duplex LC, type A/A, yellow * Leviton PCF-S2PD1RR-0100MAA 77 Threaded rod cover Chatsworth 11085-001 32 Patch cable, fiber optic, OFNP, 9/125, SM OS-2, duplex LC, type A/B, yellow * Leviton PCF-S2PD1RR-0100MAB 78 Threaded rod, 3/8"x6' Chatsworth 11440-001 33 Patch cable, fiber optic, OFNP, 50/125, MM OM-4, duplex LC, type A/A, aqua * Leviton PCF-M4PD1RR-0100MAA 79 Hardware, hex nut, 3/8"-16 Chatsworth 20142-091
34 Patch cable, fiber optic, OFNP, 50/125, MM OM-4, duplex LC, type A/B, aqua * Leviton PCF-M4PD1RR-0100MAB 80 Hardware, split lock washer, 3/8" Chatsworth 20141-090 35 Cassette, 12-fiber, 9/125, single mode OS2, 1x12F MTP, shuttered duplex LC, universal polarity, blue Leviton FM-A012CSAC0U 81 Hardware,flat washer, wide, 3/8" Chatsworth 04002-002
36 Cassette, 24-fiber, 50/125, multi mode OM4, 2x12F MTP, shuttered duplex LC, universal polarity, aqua Leviton FM-F024CSAC0U
82 Hardware,flat washer, narrow, 3/8" Chatsworth 20283-113
37 Enclosure, fiber optic, (12) SDX MTP cassettes, 19"x4U Leviton 5R4UH-W12 38 Enclosure, fiber optic, (3) SDX MTP cassettes, 19"x1U Leviton 5R1UH-W03 39 Pathways 40 Cable tray, wire mesh, 12"x4" MonoSystems MM4-12-118 41 Adaptor, conduit to tray MonoSystems MM-CTA-X 42 Ground lug, split bolt MonoSystems MM-GL-IK2 43 Splice bolt assembly MonoSystems TM-CPL-JN3 * CONTRACTOR SHALL DETERMINE PART NUMBER BASED ON LENGTH REQUIRED FOR EACH ITEM PRIOR TO
ORDERING
44 Support strut, 12" tray, pre-galvanized MonoSystems MM-P-TRP-12 45 Retaining clip MonoSystems MM-CPL-KBT 46 Cable support, steel, J-hook, 4"x3", integrated retainer clip, galvanzied MonoSystems H-433-S
1 RESPONSIBILITY MATRIX
SCALE: N.T.S. 2 PREFERRED PRODUCTS MATRIX
SCALE: N.T.S.
SHEET NOTES:
1. MATERIALS SHOWN IN THE "PREFERRED PRODUCTS MATRIX ARE THE BASIS OF DESIGN AND ARE COMPATIBLE WITH EXISTING CONDITIONS. EQUIVALENT
PRODUCTS MAY BE SUBMITTED FOR APPROVAL.
2. CONTRACTOR IS RESPONSIBLE FOR DETERMINING QUANTITIES, LENGTH, DISTANCES, COLOR, AND OTHER DETAILS.
3 CABLE SCHEDULE
SCALE: N.T.S.
CABLE SCHEDULE
DESCRIPTION CABLE TYPE UL LISTING PERFORMANCE CABLE COLOR STRANDS/PAIRS CABLE CONFIG. OUTLET COLOR
VOICE (EXISTING) UTP CMP EXISTING WHITE 4-PAIR WHITE
DATA UTP CMP CATEGORY 6A BLUE 4-PAIR BLUE/ORANGE
WIRELESS LAN UTP CMP CATEGORY 6A GREEN 4-PAIR ORANGE
SECURITY (EXISTING) UTP CMP EXISTING PURPLE (VIOLET) 4-PAIR ORANGE
GET WELL (EXISTING) UTP CMP EXISTING BROWN 4-PAIR ORANGE
GUEST WIFI (EXISTING) UTP CMP EXISTING PINK 4-PAIR ORANGE
MM - DATA RISER 50/125 OFCP* MULTI MODE AQUA 24-STRAND TIGHT BUFFER AQUA-DUPLEX LC
SM - DATA RISER 9/125 OFCP* SINGLE MODE YELLOW 24-STRAND TIGHT BUFFER BLACK-DUPLEX LC
SM - DATA RISER - OSP 9/125 OFNR** SINGLE MODE BLACK 24-STRAND LOOSE TUBE BLACK-DUPLEX LC
* INTERLOCKING ARMORED CABLE, UL LISTED OFCP FOR USE IN PLENUM SPACES.
** ALL DIELECTRIC, NON-CONDUCTING, INDOOR/OUTDOOR CABLE, UL LISTED OFNR FOR USE IN NON-PLENUM, RISER SPACES.
SCHEDULE NOTES:
1. CABLE CONNECTORS, FACEPLATES, MODULAR JACKS, PATCH CABLES, AND PATCH PANELS SHALL BE A SINGLE MANUFACTURER, SUCH AS HUBBELL OR PANDUIT.
2. CATEOGORY 6A TELECOMMUNICATIONS OUTLETS AND PATCH PANELS OUTLETS TO BE TERMINATED T568B
3. PREFERRED CABLE AND CONNECTIVITY MANUFACTURER IS PANDUIT
4. EXISTING CABLES SHALL NOT BE REMOVED DURING DEMOLITION. RE-TERMINATE ON NEW PATCH PANEL. COORIDINATE WITH COR FOR PLACEMENT.
4 TR ZONE SCHEDULE
SCALE: N.T.S.
TR ZONE TR ROOM NO. BLDG. FLOOR/LEVEL
1 A060A 1 BASEMENT
2 E006 1 BASEMENT
3 G050 1 BASEMENT
4 W05B 14 BASEMENT
5 A153A 1 1st
6 E139 1 1st
7 B144A 1 1st
8 G141 1 1st
9 C105 1 1st
10 A213 1 2nd
11 E203 1 2nd
12 A306A 1 3rd
13 C308 1 3rd
14 E326 1 3rd
15 445 1 4th
16 551 1 5th
17 650 1 6th
18 C358C 1 3rd
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
589A4-21-700
1/25/2022
100% CONSTRUCTION
DOCUMENT
EHRM Infrastructure Upgrades - Columbia, MO
800 HOSPITAL DRIVE
COLUMBIA, MO 65201
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
T-002
RESPONSIBILITY AND
PREFERRED PRODUCTS MATRIX
RMJr
#10
#9
#11
DN
UP
UPDN
F
F
F
F
F
F
F
CB
E3
F023A CBF3
F024
F001A F004
F021
F018
F020 F019 F017 F016
F015A
F015
F014
CB
F4
F005 F010
F012F013
F036F011
F009A
F009F008F007F006F003
CBF5
F001B F001
F002A
F002
E012 E001G
CBF1
E001
E009
E010
E008
E007
CBE1CBE2
E004
E005
F037STR #11
B051B048B042B039AB039
E001AE001CE001D
E001B
E002NE002M
E002O
E002F
E002E
E002D E002C E002Q
E001E
E002A
E002
E002B
E002H E002I E002J E002K E002L E001F
A001
A003 A007 A009
A010A
A010 A019 A020
37A
F029A F029 F028
F027A
F028A F025
F025A
F027 F026
F034
F034A F035A
F035
F033F032F031F030 F030A
F023 F022
E003
CBE4
A009A
CB
F2
A020A
MATCH LINE 'A'MATCH LINE 'A'
EXIST.
ELEV. LOBBY
CBE5
EXIST.
TELECOM
E006
1 DEMO FLOOR PLAN - BASEMENT - AREA 1
SCALE: 1/8 = 1'-0"
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
589A4-21-700
1/25/2022
100% CONSTRUCTION
DOCUMENT
EHRM Infrastructure Upgrades - Columbia, MO
800 HOSPITAL DRIVE
COLUMBIA, MO 65201
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
TD-100-1.B
BASEMENT TECHNOLOGY
DEMO PLAN - AREA 1
VV
KEY PLAN
N
DEMO NOTES
1. EXISTING CABLE TRAYS SHALL BE RE-USED
UNLESS OTHERWISE NOTED.
2. EXISTING J-HOOKS SHALL BE RE-USED UNLESS
OTHERWISE NOTED.
3. EXISTING TELECOMMUNICATIONS ROOM.
CONTRACTOR SHALL DEMO ALL PATCH PANELS
AND CABLING RELATED TO THIS PROJECT.
CONTRACTOR SHALL REMOVE ALL DATA CABLES
FROM THE DEVICE TO THE SOURCE.
CONTRACTOR SHALL COORDINATE WITH THE
COR PRIOR TO BEGINNING WORK IN EACH
TELECOM ROOM (TR).
4. DO NOT REMOVE ANY WALL MOUNT EQUIPMENT,
ELECTRICAL CABLES AND EQUIPMENT, OR ANY
CABLING OR DEVICE THAT IS NOT DATA
RELATED. COORDINATE WITH COR PRIOR TO
REMOVING CABLING FROM WALL FIELDS OR
FROM WALL MOUNTED EQUIPMENT.
5. BUILDING AUTOMATION SYSTEMS (BAS) OR
ELECTRONIC SECURITY SYSTEMS CABLES
SHALL NOT BE REMOVED. COORDINATE WITH
COR TO IDENTIFY BAS OR SECURITY CABLES.
6. EXISTING TELECOMMUNICATIONS OUTLET.
CONTRACTOR SHALL REMOVE ALL DEVICE
FACEPLATES AND MODULAR JACKS. EXISTING
OUTLET BOXES AND CONDUITS SHALL BE
PRESERVED FOR REUSE.
7. CONTRACTOR SHALL REMOVE ALL DATA CABLES
EXCEPT CATEGORY 6A OR UNLESS OTHERWISE
NOTED. CONTRACTOR SHALL COORDINATE
WITH THE COR PRIOR TO REMOVING CABLES,
OUTLETS, FACE PLATES, PATCH PANELS, AND
PATCH CABLES.
8. CABLES SHALL NOT BE ABANDONED IN PLACE
WITHOUT PRIOR APPROVAL OF THE COR.
9. WHERE CABLES ARE TO BE REMOVED,
CONTRACTOR SHALL COMPLETELY REMOVE THE
CABLE FROM OUTLET TO PATCH PANEL.
10.CONTRACTOR SHALL REMOVE NON-CATEGORY
6/6A FACE PLATES, MODULAR JACKS, AND
PATCH PANELS AFTER CUT OVER TO NEW
CATEGORY 6A CABLE PLANT.
11.CABLE SUPPORTS, SUCH AS CABLE TRAYS, OR
J-HOOKS, THAT ARE NOT TO BE REUSED SHALL
BE PRESERVED FOR REUSE. COORDINATE WITH
THE COR PRIOR TO REMOVING CABLE
SUPPORTS.
12.NURSE CALL SYSTEM TO BE MAINTAINED IN TR
ROOM. CONTRACTOR SHALL COORDINATE NEW
EQUIPMENT LOCATION WITH THE COR PRIOR TO
MOVING THE NURSE CALL SYSTEM OR BEFORE
WALL DEMOLITION BEGINS.
13.PRIOR TO RELOCATING WALL MOUNTED TV,
CONTRACTOR SHALL COORDINATE WITH THE
COR FOR THE NEW LOCATION AND PROVIDE
NEW CATEGORY 6A DATA AND ELECTRICAL
OUTLETS.
UP
#14
#15
#13 #12
DN
DN
DN
G014
B025
B027A
B027 CB
B3
CBG2
G001
CB
G1
G012
G013
G048
G047
G043A
G052C
G045
G046
G043
G016 G052B
G052
G036
G032
G032A
G055 G059
G052A
G030
G029
G027A
G027
CBG6
G026
G015
G031 G024A G024B
CBG5
G004
CB
G3
G040A
G042 G023
G024 G018 G017
CBG4
G037
G040 G038 G019C G019A
G019B
G019
G008
G004A
G038A
G015A
STR #G1
M
AT
C H
L
IN
E 'B
EXIST.
OFFICE
G051
EXIST.
TELECOM
G050
1 DEMO FLOOR PLAN - BASEMENT - AREA 2
SCALE: 1/8" = 1'-0"
KEYED NOTES
1. CATEGORY 6 CABLES TO REMAIN. PRESERVE
CABLES, MODULAR JACKS, AND PATCH PANELS
FOR REUSE.
2. CONTRACTOR SHALL RELOCATE NURSE CALL
CABINET OR TELEPHONE BACKBOARD
COORDINATING THE NEW LOCATION WITH THE
COR.
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
589A4-21-700
1/25/2022
100% CONSTRUCTION
DOCUMENT
EHRM Infrastructure Upgrades - Columbia, MO
800 HOSPITAL DRIVE
COLUMBIA, MO 65201
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
TD-101-1.B
BASEMENT TECHNOLOGY
DEMO PLAN - AREA 2
VV
KEY PLAN
N
DEMO NOTES
1. EXISTING CABLE TRAYS SHALL BE RE-USED
UNLESS OTHERWISE NOTED.
2. EXISTING J-HOOKS SHALL BE RE-USED UNLESS
OTHERWISE NOTED.
3. EXISTING TELECOMMUNICATIONS ROOM.
CONTRACTOR SHALL DEMO ALL PATCH PANELS
AND CABLING RELATED TO THIS PROJECT.
CONTRACTOR SHALL REMOVE ALL DATA CABLES
FROM THE DEVICE TO THE SOURCE.
CONTRACTOR SHALL COORDINATE WITH THE
COR PRIOR TO BEGINNING WORK IN EACH
TELECOM ROOM (TR).
4. DO NOT REMOVE ANY WALL MOUNT EQUIPMENT,
ELECTRICAL CABLES AND EQUIPMENT, OR ANY
CABLING OR DEVICE THAT IS NOT DATA
RELATED. COORDINATE WITH COR PRIOR TO
REMOVING CABLING FROM WALL FIELDS OR
FROM WALL MOUNTED EQUIPMENT.
5. BUILDING AUTOMATION SYSTEMS (BAS) OR
ELECTRONIC SECURITY SYSTEMS CABLES
SHALL NOT BE REMOVED. COORDINATE WITH
COR TO IDENTIFY BAS OR SECURITY CABLES.
6. EXISTING TELECOMMUNICATIONS OUTLET.
CONTRACTOR SHALL REMOVE ALL DEVICE
FACEPLATES AND MODULAR JACKS. EXISTING
OUTLET BOXES AND CONDUITS SHALL BE
PRESERVED FOR REUSE.
7. CONTRACTOR SHALL REMOVE ALL DATA CABLES
EXCEPT CATEGORY 6A OR UNLESS OTHERWISE
NOTED. CONTRACTOR SHALL COORDINATE
WITH THE COR PRIOR TO REMOVING CABLES,
OUTLETS, FACE PLATES, PATCH PANELS, AND
PATCH CABLES.
8. CABLES SHALL NOT BE ABANDONED IN PLACE
WITHOUT PRIOR APPROVAL OF THE COR.
9. WHERE CABLES ARE TO BE REMOVED,
CONTRACTOR SHALL COMPLETELY REMOVE THE
CABLE FROM OUTLET TO PATCH PANEL.
10.CONTRACTOR SHALL REMOVE NON-CATEGORY
6/6A FACE PLATES, MODULAR JACKS, AND
PATCH PANELS AFTER CUT OVER TO NEW
CATEGORY 6A CABLE PLANT.
11.CABLE SUPPORTS, SUCH AS CABLE TRAYS, OR
J-HOOKS, THAT ARE NOT TO BE REUSED SHALL
BE PRESERVED FOR REUSE. COORDINATE WITH
THE COR PRIOR TO REMOVING CABLE
SUPPORTS.
12.NURSE CALL SYSTEM TO BE MAINTAINED IN TR
ROOM. CONTRACTOR SHALL COORDINATE NEW
EQUIPMENT LOCATION WITH THE COR PRIOR TO
MOVING THE NURSE CALL SYSTEM OR BEFORE
WALL DEMOLITION BEGINS.
13.PRIOR TO RELOCATING WALL MOUNTED TV,
CONTRACTOR SHALL COORDINATE WITH THE
COR FOR THE NEW LOCATION AND PROVIDE
NEW CATEGORY 6A DATA AND ELECTRICAL
UP
#4
#5
#7
#8
REX
#1#2#3
DN
UP
DN
A058
B013
B013A
B011B
B011A
B011C B011D B011E B011F B011G
B011
B011H
B011J B009
B007
B010
B010A
B006C
B006
B006B
B006A
B009A
B036A
ST
R
B036B
B034 B036
A056
STR #1
B025
B027A
B024 B019
B027
B031
CB
B3
B030
B026 B023
B032
B014
B016
B018
B022 B021
B017
B045
B015
B012
B046A
B047 B046 B049
B050
CB
A1
B051B048B042B039AB039
CBB3
A055
A054B
A004
E001E
E002B
E002H E002I E002J E002K E002L
A001
A002 A003
CBA2
A007 A009
CBA3 CBA4
A005
A004A
A006 A008A A008
A012
A013
A047
CBA8
A060
D004L
A048
A049
A006A
A051
A51A
A050
CBA9
A052
CBA10
A053
A059A
A059
A057
D004M
D004N
D002
D001B
D001A
D001
D004E
D004BD004AD004O
D031
D003
D003B D004G
D004H
D028 D003A D004I
CBB1
B033
B033A
B037A
B037 A009A
B002D
B002G
B002F
B002K
B002A
B002
B001F
B002E
C009D
C009
C009B
C001
C009A
B001E
B001B
B001D
B0
C
B001A
C001A C001C
C001D
CB
D4
C009C
CBD1
CB
B4
A054
A016A
A016
MATCH LINE 'A'
MATCH LINE 'C'
EXIST.
TELECOM
A056A
NOT IN SCOPE.
KITCHEN RENO PROJECT
1 DEMO FLOOR PLAN - BASEMENT - AREA 3 & 4
SCALE: 1/8" = 1'-0"
KEYED NOTES
1. EXISTING TELECOM SERVICE PROVIDER RACKS
TO REMAIN. NOT IN SCOPE OF WORK FOR THIS
PROJECT.
2. EXISTING TELECOM ROOM TO BE RELOCATED
TO NEW TELECOM ROOM TR A060.
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
589A4-21-700
1/25/2022
100% CONSTRUCTION
DOCUMENT
EHRM Infrastructure Upgrades - Columbia, MO
800 HOSPITAL DRIVE
COLUMBIA, MO 65201
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
TD-102-1.B
BASEMENT TECHNOLOGY
DEMO PLAN AREA 3 & 4
VV
KEY PLAN
N
DEMO NOTES
1. EXISTING CABLE TRAYS SHALL BE RE-USED
UNLESS OTHERWISE NOTED.
2. EXISTING J-HOOKS SHALL BE RE-USED UNLESS
OTHERWISE NOTED.
3. EXISTING TELECOMMUNICATIONS ROOM.
CONTRACTOR SHALL DEMO ALL PATCH PANELS
AND CABLING RELATED TO THIS PROJECT.
CONTRACTOR SHALL REMOVE ALL DATA CABLES
FROM THE DEVICE TO THE SOURCE.
CONTRACTOR SHALL COORDINATE WITH THE
COR PRIOR TO BEGINNING WORK IN EACH
TELECOM ROOM (TR).
4. DO NOT REMOVE ANY WALL MOUNT EQUIPMENT,
ELECTRICAL CABLES AND EQUIPMENT, OR ANY
CABLING OR DEVICE THAT IS NOT DATA
RELATED. COORDINATE WITH COR PRIOR TO
REMOVING CABLING FROM WALL FIELDS OR
FROM WALL MOUNTED EQUIPMENT.
5. BUILDING AUTOMATION SYSTEMS (BAS) OR
ELECTRONIC SECURITY SYSTEMS CABLES
SHALL NOT BE REMOVED. COORDINATE WITH
COR TO IDENTIFY BAS OR SECURITY CABLES.
6. EXISTING TELECOMMUNICATIONS OUTLET.
CONTRACTOR SHALL REMOVE ALL DEVICE
FACEPLATES AND MODULAR JACKS. EXISTING
OUTLET BOXES AND CONDUITS SHALL BE
PRESERVED FOR REUSE.
7. CONTRACTOR SHALL REMOVE ALL DATA CABLES
EXCEPT CATEGORY 6A OR UNLESS OTHERWISE
NOTED. CONTRACTOR SHALL COORDINATE
WITH THE COR PRIOR TO REMOVING CABLES,
OUTLETS, FACE PLATES, PATCH PANELS, AND
PATCH CABLES.
8. CABLES SHALL NOT BE ABANDONED IN PLACE
WITHOUT PRIOR APPROVAL OF THE COR.
9. WHERE CABLES ARE TO BE REMOVED,
CONTRACTOR SHALL COMPLETELY REMOVE THE
CABLE FROM OUTLET TO PATCH PANEL.
10.CONTRACTOR SHALL REMOVE NON-CATEGORY
6/6A FACE PLATES, MODULAR JACKS, AND
PATCH PANELS AFTER CUT OVER TO NEW
CATEGORY 6A CABLE PLANT.
11.CABLE SUPPORTS, SUCH AS CABLE TRAYS, OR
J-HOOKS, THAT ARE NOT TO BE REUSED SHALL
BE PRESERVED FOR REUSE. COORDINATE WITH
THE COR PRIOR TO REMOVING CABLE
SUPPORTS.
12.NURSE CALL SYSTEM TO BE MAINTAINED IN TR
ROOM. CONTRACTOR SHALL COORDINATE NEW
EQUIPMENT LOCATION WITH THE COR PRIOR TO
MOVING THE NURSE CALL SYSTEM OR BEFORE
WALL DEMOLITION BEGINS.
13.PRIOR TO RELOCATING WALL MOUNTED TV,
CONTRACTOR SHALL COORDINATE WITH THE
COR FOR THE NEW LOCATION AND PROVIDE
NEW CATEGORY 6A DATA AND ELECTRICAL
#5
#6
REX
DN
DN
DN
UP
DN DN
UP
UP
DN
DN
DN
DN
UP
UP
.4
.5
.5
.5
D027
CBD3
C006A
C006
STR #7
D021A
D021
STR #6
CBD7
D022
D020
D023
D022CD022D
D022A
D002D001
D004BD004AD004O
D031
D003
D003B D004G
D004H
D028
D029
D003A
D003C
D004I
D004J
D004KD003D
CBD5
D025D030
D024
D019C
C003A
C003B
C003C
C004D
C004BC004AC004
C005A
C005
C003
C003E
C011
C014C013C013A
B002E
C009D
C009
C009B
C001
C009A C001A C001C
C001D
CB
D4
C002
C002B C008
C0
J
C009C
C009E
C009F C009G
C009I
C009K
CBC1
C009H
C009M
C010
C009N
CBC1A
C003F C003D
D019A
D019B
D019D D019
D019C
CBC2
CB
C3
CBD1
C002A
D026
STR#9
D018
STR #17
MATCH LINE 'C'
NOT IN SCOPE.
MORGUE RENO. PROJECT
1 DEMO FLOOR PLAN - BASEMENT - AREA 3A & 4A
SCALE: 1/8" = 1'-0"
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
589A4-21-700
1/25/2022
100% CONSTRUCTION
DOCUMENT
EHRM Infrastructure Upgrades - Columbia, MO
800 HOSPITAL DRIVE
COLUMBIA, MO 65201
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
TD-103-1.B
BASEMENT TECHNOLOGY
DEMO PLAN - AREA 3A & 4A
VV
KEY PLAN
N
DEMO NOTES
1. EXISTING CABLE TRAYS SHALL BE RE-USED
UNLESS OTHERWISE NOTED.
2. EXISTING J-HOOKS SHALL BE RE-USED UNLESS
OTHERWISE NOTED.
3. EXISTING TELECOMMUNICATIONS ROOM.
CONTRACTOR SHALL DEMO ALL PATCH PANELS
AND CABLING RELATED TO THIS PROJECT.
CONTRACTOR SHALL REMOVE ALL DATA CABLES
FROM THE DEVICE TO THE SOURCE.
CONTRACTOR SHALL COORDINATE WITH THE
COR PRIOR TO BEGINNING WORK IN EACH
TELECOM ROOM (TR).
4. DO NOT REMOVE ANY WALL MOUNT EQUIPMENT,
ELECTRICAL CABLES AND EQUIPMENT, OR ANY
CABLING OR DEVICE THAT IS NOT DATA
RELATED. COORDINATE WITH COR PRIOR TO
REMOVING CABLING FROM WALL FIELDS OR
FROM WALL MOUNTED EQUIPMENT.
5. BUILDING AUTOMATION SYSTEMS (BAS) OR
ELECTRONIC SECURITY SYSTEMS CABLES
SHALL NOT BE REMOVED. COORDINATE WITH
COR TO IDENTIFY BAS OR SECURITY CABLES.
6. EXISTING TELECOMMUNICATIONS OUTLET.
CONTRACTOR SHALL REMOVE ALL DEVICE
FACEPLATES AND MODULAR JACKS. EXISTING
OUTLET BOXES AND CONDUITS SHALL BE
PRESERVED FOR REUSE.
7. CONTRACTOR SHALL REMOVE ALL DATA CABLES
EXCEPT CATEGORY 6A OR UNLESS OTHERWISE
NOTED. CONTRACTOR SHALL COORDINATE
WITH THE COR PRIOR TO REMOVING CABLES,
OUTLETS, FACE PLATES, PATCH PANELS, AND
PATCH CABLES.
8. CABLES SHALL NOT BE ABANDONED IN PLACE
WITHOUT PRIOR APPROVAL OF THE COR.
9. WHERE CABLES ARE TO BE REMOVED,
CONTRACTOR SHALL COMPLETELY REMOVE THE
CABLE FROM OUTLET TO PATCH PANEL.
10.CONTRACTOR SHALL REMOVE NON-CATEGORY
6/6A FACE PLATES, MODULAR JACKS, AND
PATCH PANELS AFTER CUT OVER TO NEW
CATEGORY 6A CABLE PLANT.
11.CABLE SUPPORTS, SUCH AS CABLE TRAYS, OR
J-HOOKS, THAT ARE NOT TO BE REUSED SHALL
BE PRESERVED FOR REUSE. COORDINATE WITH
THE COR PRIOR TO REMOVING CABLE
SUPPORTS.
12.NURSE CALL SYSTEM TO BE MAINTAINED IN TR
ROOM. CONTRACTOR SHALL COORDINATE NEW
EQUIPMENT LOCATION WITH THE COR PRIOR TO
MOVING THE NURSE CALL SYSTEM OR BEFORE
WALL DEMOLITION BEGINS.
13.PRIOR TO RELOCATING WALL MOUNTED TV,
CONTRACTOR SHALL COORDINATE WITH THE
COR FOR THE NEW LOCATION AND PROVIDE
NEW CATEGORY 6A DATA AND ELECTRICAL
A063C A063G
A063
A063A
A063H
A063D A063F
A024A
D008 D004
D009
CB
D2
D007
D005AD005
D006
D004C
D004F
E001E2L E001F
CBA4
A012
A013
A010A
A010 A019 A020
A024
A024B
ST
R
A026
A027A
A027
A028
A022
A018
A025BA025CBA5
A023 A029
A023A A031
CB
A7
CB
A6
A021
A045A
A015A A015
A011
A014 A030
A032
A034 A033
A033
A035
A042A
A042A043A045A017
A033A
A033B
A038
A037
A036
A039A040A041
CBA8
A046
A047A
A047
CBA11
CBA8
004G
004H
004I
A009A
A020A
A016A
A016
A063EA063B
MATCH LINE 'A'
MATCH LINE 'C'
M
AT
C H
L
IN
E 'D
M
RANCE
1 DEMO FLOOR PLAN - BASEMENT - AREA 5
SCALE: 1/8" = 1'-0"
N
UP
DN
D021
STR #6
D015
D022B
D012
D010
D008 D004
D017
D016
D013
D0
A
D015A
ST
R
D011
D009
CB
D2
D007
D014
004G
004H
004I
004J
004K
PB01C
STR #12 #17
MATCH LINE 'C'
M
AT
C H
L
IN
E 'D
2 DEMO FLOOR PLAN - BASEMENT - AREA 5
SCALE: 1/8" = 1'-0"
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
589A4-21-700
1/25/2022
100% CONSTRUCTION
DOCUMENT
EHRM Infrastructure Upgrades - Columbia, MO
800 HOSPITAL DRIVE
COLUMBIA, MO 65201
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
TD-104-1.B
BASEMENT TECHNOLOGY
DEMO PLAN - AREA 5
VV
KEY PLAN
NN
DEMO NOTES
1. EXISTING CABLE TRAYS SHALL BE RE-USED
UNLESS OTHERWISE NOTED.
2. EXISTING J-HOOKS SHALL BE RE-USED UNLESS
OTHERWISE NOTED.
3. EXISTING TELECOMMUNICATIONS ROOM.
CONTRACTOR SHALL DEMO ALL PATCH PANELS
AND CABLING RELATED TO THIS PROJECT.
CONTRACTOR SHALL REMOVE ALL DATA CABLES
FROM THE DEVICE TO THE SOURCE.
CONTRACTOR SHALL COORDINATE WITH THE
COR PRIOR TO BEGINNING WORK IN EACH
TELECOM ROOM (TR).
4. DO NOT REMOVE ANY WALL MOUNT EQUIPMENT,
ELECTRICAL CABLES AND EQUIPMENT, OR ANY
CABLING OR DEVICE THAT IS NOT DATA
RELATED. COORDINATE WITH COR PRIOR TO
REMOVING CABLING FROM WALL FIELDS OR
FROM WALL MOUNTED EQUIPMENT.
5. BUILDING AUTOMATION SYSTEMS (BAS) OR
ELECTRONIC SECURITY SYSTEMS CABLES
SHALL NOT BE REMOVED. COORDINATE WITH
COR TO IDENTIFY BAS OR SECURITY CABLES.
6. EXISTING TELECOMMUNICATIONS OUTLET.
CONTRACTOR SHALL REMOVE ALL DEVICE
FACEPLATES AND MODULAR JACKS. EXISTING
OUTLET BOXES AND CONDUITS SHALL BE
PRESERVED FOR REUSE.
7. CONTRACTOR SHALL REMOVE ALL DATA CABLES
EXCEPT CATEGORY 6A OR UNLESS OTHERWISE
NOTED. CONTRACTOR SHALL COORDINATE
WITH THE COR PRIOR TO REMOVING CABLES,
OUTLETS, FACE PLATES, PATCH PANELS, AND
PATCH CABLES.
8. CABLES SHALL NOT BE ABANDONED IN PLACE
WITHOUT PRIOR APPROVAL OF THE COR.
9. WHERE CABLES ARE TO BE REMOVED,
CONTRACTOR SHALL COMPLETELY REMOVE THE
CABLE FROM OUTLET TO PATCH PANEL.
10.CONTRACTOR SHALL REMOVE NON-CATEGORY
6/6A FACE PLATES, MODULAR JACKS, AND
PATCH PANELS AFTER CUT OVER TO NEW
CATEGORY 6A CABLE PLANT.
11.CABLE SUPPORTS, SUCH AS CABLE TRAYS, OR
J-HOOKS, THAT ARE NOT TO BE REUSED SHALL
BE PRESERVED FOR REUSE. COORDINATE WITH
THE COR PRIOR TO REMOVING CABLE
SUPPORTS.
12.NURSE CALL SYSTEM TO BE MAINTAINED IN TR
ROOM. CONTRACTOR SHALL COORDINATE NEW
EQUIPMENT LOCATION WITH THE COR PRIOR TO
MOVING THE NURSE CALL SYSTEM OR BEFORE
WALL DEMOLITION BEGINS.
13.PRIOR TO RELOCATING WALL MOUNTED TV,
CONTRACTOR SHALL COORDINATE WITH THE
COR FOR THE NEW LOCATION AND PROVIDE
NEW CATEGORY 6A DATA AND ELECTRICAL
M V
M
AO2
M V
M
AO2
EX
T3
EXT30EXT36
EX
T3
EXT30 EXT36
FE
FE
FE
FE
FE
FE
FE
UP
UP
#10
#9
#11
E109 E110E125F
E125EC1E24
E125DE125CE125BE125A
E124
E123
E126
C
E2
E133
E122 E121 E120
E117 E116
E115
E114
E130
E131
E132
E112
E111
E129
E127
B109 B110 B112
F100
B131A
C
E6
E137
E102LE102G
E102F E102E E102D E102C E102B E102A
F129
F135
C1E14
E102J E102K
F104
E-1204
F171
F128
F134
C1E13
E108B
F122
C1E21
F171A F150
F101
F125
E102H
E107
E108
C 1F
F123
F151B
F102
F126
E102
E106
E108C
C1F11
F124
F151A
C1F7
C1E12
E144
E140
F168
F137A
C1F7
F121
F137
F169
E146
E148
E138
C1E11
C1F1
C1F19
C
F1
C1F2
C1F21
E147
C1E8 E145
E143
F136
F118
F117
B138
F163
C1E15
C1F20
F103
F160
F161
B134
F116
C1F6
C 1F
F115
C1E16
F164
E134
C1E10
F166
F167
F165
F162
B137
C
F9
F109
F108
C1F8
F146 F131
C1F15
F105
F113
F114A
F127 F130
F103B
F114
F132
F151
F149
C1E17
F119
F107
F106
F112 F155
F147
F152
C
F1
C
F1 4 F144
F138
F153
F138A
F145
F148
F110 F111 F142F141F140F139 F156
C1F12 C1F13
F133
F157 F158 F159
C1F17
F142 F154
F120
E127A
F103A
B134A
MATCH LINE 'A'
M
AT
C H
L
IN
E 'D
BREAK
ROOM
EXIST.
TELECOM
B144A
LOCKERS
B143
EXIST.
TOILET
B144B
EXIST.
ELEV. LOBBY
C1E9
EXIST.
TELECOM
E139
2 2 2
2 2 2
2 2 2 2
2 2 2 2 2 2
2 2
2 2
2 2 2
2 2
2 2
4 2 2
2 2
2 2
2 2
1 1
2 23
3 2
1 DEMO FLOOR PLAN - FIRST FLOOR - AREA 1
SCALE: 1/8 = 1'-0"
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
589A4-21-700
1/25/2022
100% CONSTRUCTION
DOCUMENT
EHRM Infrastructure Upgrades - Columbia, MO
800 HOSPITAL DRIVE
COLUMBIA, MO 65201
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
TD-105-1.1
FIRST FLOOR TECHNOLOGY
DEMO PLAN- AREA 1
VV
KEY PLAN
N
DEMO NOTES
1. EXISTING CABLE TRAYS SHALL BE RE-USED
UNLESS OTHERWISE NOTED.
2. EXISTING J-HOOKS SHALL BE RE-USED UNLESS
OTHERWISE NOTED.
3. EXISTING TELECOMMUNICATIONS ROOM.
CONTRACTOR SHALL DEMO ALL PATCH PANELS
AND CABLING RELATED TO THIS PROJECT.
CONTRACTOR SHALL REMOVE ALL DATA CABLES
FROM THE DEVICE TO THE SOURCE.
CONTRACTOR SHALL COORDINATE WITH THE
COR PRIOR TO BEGINNING WORK IN EACH
TELECOM ROOM (TR).
4. DO NOT REMOVE ANY WALL MOUNT EQUIPMENT,
ELECTRICAL CABLES AND EQUIPMENT, OR ANY
CABLING OR DEVICE THAT IS NOT DATA
RELATED. COORDINATE WITH COR PRIOR TO
REMOVING CABLING FROM WALL FIELDS OR
FROM WALL MOUNTED EQUIPMENT.
5. BUILDING AUTOMATION SYSTEMS (BAS) OR
ELECTRONIC SECURITY SYSTEMS CABLES
SHALL NOT BE REMOVED. COORDINATE WITH
COR TO IDENTIFY BAS OR SECURITY CABLES.
6. EXISTING TELECOMMUNICATIONS OUTLET.
CONTRACTOR SHALL REMOVE ALL DEVICE
FACEPLATES AND MODULAR JACKS. EXISTING
OUTLET BOXES AND CONDUITS SHALL BE
PRESERVED FOR REUSE.
7. CONTRACTOR SHALL REMOVE ALL DATA CABLES
EXCEPT CATEGORY 6A OR UNLESS OTHERWISE
NOTED. CONTRACTOR SHALL COORDINATE
WITH THE COR PRIOR TO REMOVING CABLES,
OUTLETS, FACE PLATES, PATCH PANELS, AND
PATCH CABLES.
8. CABLES SHALL NOT BE ABANDONED IN PLACE
WITHOUT PRIOR APPROVAL OF THE COR.
9. WHERE CABLES ARE TO BE REMOVED,
CONTRACTOR SHALL COMPLETELY REMOVE THE
CABLE FROM OUTLET TO PATCH PANEL.
10.CONTRACTOR SHALL REMOVE NON-CATEGORY
6/6A FACE PLATES, MODULAR JACKS, AND
PATCH PANELS AFTER CUT OVER TO NEW
CATEGORY 6A CABLE PLANT.
11.CABLE SUPPORTS, SUCH AS CABLE TRAYS, OR
J-HOOKS, THAT ARE NOT TO BE REUSED SHALL
BE PRESERVED FOR REUSE. COORDINATE WITH
THE COR PRIOR TO REMOVING CABLE
SUPPORTS.
12.NURSE CALL SYSTEM TO BE MAINTAINED IN TR
ROOM. CONTRACTOR SHALL COORDINATE NEW
EQUIPMENT LOCATION WITH THE COR PRIOR TO
MOVING THE NURSE CALL SYSTEM OR BEFORE
WALL DEMOLITION BEGINS.
13.PRIOR TO RELOCATING WALL MOUNTED TV,
CONTRACTOR SHALL COORDINATE WITH THE
COR FOR THE NEW LOCATION AND PROVIDE
NEW CATEGORY 6A DATA AND ELECTRICAL
FE
FE
FE
DN
UP
UP
DN
F175
F174C
F174B
F174A
C1E33
C1E31
F181
A130
C
E6
E102L
C1E35
C1E29
F176
F174
E102C E102B E102A
E-1100
E102J E102K
F171
F171A F150
E102H
F151B
E102
F151A
E144
E140
F168 F169
E146
C1F19
C
F1
C1E8 E145
E143
F163
F179B
F177
F160 F177A
F178
F161
F164
F1 F2
C1E32
F166
F167
F165
F162
F179
C1F22
F170
F151
F180
156 F157 F158 F159
C1F17
A119A A121 A123 A125
C1E30
E100A
E142
E141
E100
E101
MATCH LINE 'A'
M
AT
C H
L
IN
E 'D
2 2 2
2 2 2 2
2 2 2
2 2
2 3
2 2
3 3
2 3
2 2 2 22
1 DEMO FLOOR PLAN - FIRST FLOOR - AREA 1A
SCALE: 1/8 = 1'-0"
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
589A4-21-700
1/25/2022
100% CONSTRUCTION
DOCUMENT
EHRM Infrastructure Upgrades - Columbia, MO
800 HOSPITAL DRIVE
COLUMBIA, MO 65201
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
TD-106-1.1
FIRST FLOOR TECHNOLOGY
DEMO PLAN- AREA 1A
VV
KEY PLAN
N
DEMO NOTES
1. EXISTING CABLE TRAYS SHALL BE RE-USED
UNLESS OTHERWISE NOTED.
2. EXISTING J-HOOKS SHALL BE RE-USED UNLESS
OTHERWISE NOTED.
3. EXISTING TELECOMMUNICATIONS ROOM.
CONTRACTOR SHALL DEMO ALL PATCH PANELS
AND CABLING RELATED TO THIS PROJECT.
CONTRACTOR SHALL REMOVE ALL DATA CABLES
FROM THE DEVICE TO THE SOURCE.
CONTRACTOR SHALL COORDINATE WITH THE
COR PRIOR TO BEGINNING WORK IN EACH
TELECOM ROOM (TR).
4. DO NOT REMOVE ANY WALL MOUNT EQUIPMENT,
ELECTRICAL CABLES AND EQUIPMENT, OR ANY
CABLING OR DEVICE THAT IS NOT DATA
RELATED. COORDINATE WITH COR PRIOR TO
REMOVING CABLING FROM WALL FIELDS OR
FROM WALL MOUNTED EQUIPMENT.
5. BUILDING AUTOMATION SYSTEMS (BAS) OR
ELECTRONIC SECURITY SYSTEMS CABLES
SHALL NOT BE REMOVED. COORDINATE WITH
COR TO IDENTIFY BAS OR SECURITY CABLES.
6. EXISTING TELECOMMUNICATIONS OUTLET.
CONTRACTOR SHALL REMOVE ALL DEVICE
FACEPLATES AND MODULAR JACKS. EXISTING
OUTLET BOXES AND CONDUITS SHALL BE
PRESERVED FOR REUSE.
7. CONTRACTOR SHALL REMOVE ALL DATA CABLES
EXCEPT CATEGORY 6A OR UNLESS OTHERWISE
NOTED. CONTRACTOR SHALL COORDINATE
WITH THE COR PRIOR TO REMOVING CABLES,
OUTLETS, FACE PLATES, PATCH PANELS, AND
PATCH CABLES.
8. CABLES SHALL NOT BE ABANDONED IN PLACE
WITHOUT PRIOR APPROVAL OF THE COR.
9. WHERE CABLES ARE TO BE REMOVED,
CONTRACTOR SHALL COMPLETELY REMOVE THE
CABLE FROM OUTLET TO PATCH PANEL.
10.CONTRACTOR SHALL REMOVE NON-CATEGORY
6/6A FACE PLATES, MODULAR JACKS, AND
PATCH PANELS AFTER CUT OVER TO NEW
CATEGORY 6A CABLE PLANT.
11.CABLE SUPPORTS, SUCH AS CABLE TRAYS, OR
J-HOOKS, THAT ARE NOT TO BE REUSED SHALL
BE PRESERVED FOR REUSE. COORDINATE WITH
THE COR PRIOR TO REMOVING CABLE
SUPPORTS.
12.NURSE CALL SYSTEM TO BE MAINTAINED IN TR
ROOM. CONTRACTOR SHALL COORDINATE NEW
EQUIPMENT LOCATION WITH THE COR PRIOR TO
MOVING THE NURSE CALL SYSTEM OR BEFORE
WALL DEMOLITION BEGINS.
13.PRIOR TO RELOCATING WALL MOUNTED TV,
CONTRACTOR SHALL COORDINATE WITH THE
COR FOR THE NEW LOCATION AND PROVIDE
NEW CATEGORY 6A DATA AND ELECTRICAL
9*
N7
F
F
F
F F
F
F
F
#14
#13 #12
#15
C133C
C133B
C111
C112
C1
B176C
B176B
B176
C
G
G176
G100
G101
G102
G102A
G160
G103
G
G105
G106
G
G105A
G108
G114A
G
G116
G114
G115
G113G112
G156
G173G
G111
G110
G110A
G
G148 G147 G146 G171
G145 G143A
G144
G142A G168
G142
G170
G169 G143
G107
G191
G136 G139
G155
G155B
G137
G138
G163 G162
G120
G121
G123
G122
G133
G127 G128
G159
G
G
G129
G130
G131
G132
G119
G124 G
5 G118 G161
G164A C104
G164
C110
G135 G140
G
A
G193
G149
G150
G150A
G151 G153
B176D
G152
G196E
G196H G196G G196F
G192
M
AT
C H
L
IN
E 'B
MATCH LINE 'F'
EXIST.
TELECOM
G141
2 2
1 41 4
4 1 3
4 1
2 21
22 22
2 2
2 2
2 2
1 DEMO FLOOR PLAN - FIRST FLOOR - AREA 2
SCALE: 1/8" = 1'-0"
Project Number
Building Number
Drawing Number
DrawnCheckedIssue Date
Location
Project Title
21 3 4 5 6 7 8 9 10
21 3 4 5 6 7 8 9 10
B
A
C
D
E
F
B
A
C
D
E
F
PhaseDrawing Title
Approved: Project Director
PROJECT MANAGEMENTCONSULTANTRevisions: Date:
U.S. Department of Veterans Affairs
Construction and Facilities Management
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
FULLY SPRINKLERED
589A4-21-700
1/25/2022
100% CONSTRUCTION
DOCUMENT
EHRM Infrastructure Upgrades - Columbia, MO
800 HOSPITAL DRIVE
COLUMBIA, MO 65201
8718 Botts Lane Phone: (210) 816-4784 San Antonio, Texas 78217 Fax: (210) 881-6808 www.hfscompany.com jbianco@hfscompany.com
TD-107-1.1
FIRST FLOOR TECHNOLOGY
DEMO PLAN- AREA 2
VV
KEY PLAN
N
DEMO NOTES
1. EXISTING CABLE TRAYS SHALL BE RE-USED
UNLESS OTHERWISE NOTED.
2. EXISTING J-HOOKS SHALL BE RE-USED UNLESS
OTHERWISE NOTED.
3. EXISTING TELECOMMUNICATIONS ROOM.
CONTRACTOR SHALL DEMO ALL PATCH PANELS
AND CABLING RELATED TO THIS PROJECT.
CONTRACTOR SHALL REMOVE ALL DATA CABLES
FROM THE DEVICE TO THE SOURCE.
CONTRACTOR SHALL COORDINATE WITH THE
COR PRIOR TO BEGINNING WORK IN EACH
TELECOM ROOM (TR).
4. DO NOT REMOVE ANY WALL MOUNT EQUIPMENT,
ELECTRICAL CABLES AND EQUIPMENT, OR ANY
CABLING OR DEVICE THAT IS NOT DATA
RELATED. COORDINATE WITH COR PRIOR TO
REMOVING CABLING FROM WALL FIELDS OR
FROM WALL MOUNTED EQUIPMENT.
5. BUILDING AUTOMATION SYSTEMS (BAS) OR
ELECTRONIC SECURITY SYSTEMS CABLES
SHALL NOT BE REMOVED. COORDINATE WITH
COR TO IDENTIFY BAS OR SECURITY CABLES.
6. EXISTING TELECOMMUNICATIONS OUTLET.
CONTRACTOR SHALL REMOVE ALL DEVICE
FACEPLATES AND MODULAR JACKS. EXISTING
OUTLET BOXES AND CONDUITS SHALL BE
PRESERVED FOR REUSE.
7. CONTRACTOR SHALL REMOVE ALL DATA CABLES
EXCEPT CATEGORY 6A OR UNLESS OTHERWISE
NOTED. CONTRACTOR SHALL COORDINATE
WITH THE COR PRIOR TO REMOVING CABLES,
OUTLETS, FACE PLATES, PATCH PANELS, AND
PATCH CABLES.
8. CABLES SHALL NOT BE ABANDONED IN PLACE
WITHOUT PRIOR APPROVAL OF THE COR.
9. WHERE CABLES ARE TO BE REMOVED,
CONTRACTOR SHALL COMPLETELY REMOVE THE
CABLE FROM OUTLET TO PATCH PANEL.
10.CONTRACTOR SHALL REMOVE NON-CATEGORY
6/6A FACE PLATES, MODULAR JACKS, AND
PATCH PANELS…