Attachment A _Roof Plans_Site Layout.pdf

PDF 301 KB Posted

Attached to
Y1DZ--589A4-21-700 EHRM Infrastructure Upgrades Construction Columbia, MO
Solicitation number
36C77622R0069
Issued by

About this file

This document contains a roof plan and site layout diagram for a hospital facility along with details of an associated federal contract opportunity for infrastructure upgrades at a VA location in Columbia, Missouri. The roof plan outlines the various roof sections, materials, contractors, and warranty expiration dates. The federal contract opportunity involves providing all labor, project management, materials, tools, and equipment to complete infrastructure upgrades per drawings and specifications. The solicitation was issued by the Department of Veterans Affairs Technology Acquisition Center in Austin, Texas. The upgrades are for EHRM infrastructure at the VA facility in Columbia and the response due date is not specified.

View the file

Other files

File Type Posted
Answers to Technical Questions 7-15-22.pdf PDF
36C77622R0069 0007 Amendment 0007 7-15-22.pdf PDF
TERRACON ASBESTOS SURVEY Final Report-NESHAP Survey Report_updated as removed.pdf PDF
36C77622R0069 0006 Amendment 0006 7-7-2022.pdf PDF
Answers_Clarifications to Technical Questions 7-7-22.pdf PDF
Answers to Technical Questions 6-29-22.pdf PDF
36C77622R0069 0005 Amendment 0005 6-29-2022.pdf PDF
36C77622R0069 0004 Amendment 0004 6-27-2022.pdf PDF
36C77622R0069 0003 - Amendment 0003 - 6-22-2022.pdf PDF
36C77622R0069 0002 - Amendment 0002 - 6-16-2022.pdf PDF
Construction Wage Rates - Boone County - 5-27-22.pdf PDF
Site Visit Sign-In-Sheet 6-9-22.pdf PDF
36C77622R0069 0001 - Amendment 0001 - 6-9-22.pdf PDF
Attachment C - VA Notice of Limitations on Subcontracting-Certificate of Compliance.docx DOCX document
Final Drawings_Part3.pdf PDF
Construction Wage Rates - Boone County - 4-22-22.pdf PDF
Attachment A - PPQ.docx DOCX document
Final Specifications-Vol 1_Rev2 - 3-28-22.pdf PDF
Attachment D - Contractor Safety and Environmental Record Evaluation Form.docx DOCX document
Attachment B - VHA Suppl. Contract Rqmnts for Combatting COVID-19 Updated 12-14-2021.pdf PDF
Final Specifications-Vol 2_Rev2 - 3-28-22.pdf PDF
Final Drawings_Part6.pdf PDF
Final Drawings_Part7.pdf PDF
Final Drawings_Part2.pdf PDF
Final Drawings_Part1.pdf PDF
36C77622R0069 Columbia EHRM Infra - 5-19-22.pdf PDF
Final Drawings_Part9.pdf PDF
Final Drawings_Part8.pdf PDF
Final Narrative.pdf PDF
Final Drawings_Part4.pdf PDF
Final Drawings_Part5.pdf PDF
Show all 31

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

H D

L

DL

D

L

D

PENTHOUSE

46 SQ / 4,600 SF

Garland Company, Inc. /

Shay Roofing, Inc.

1300549-A - Garla-Shield

EXP: 9/12/2023

(SHUT DOWN REQUIRED)

SIXTH FLOOR

189 SQ / 18,900 SF

Garland Company, Inc. / Shay Roofing, Inc.

1300549-B - Garla-Shield

EXP: 9/12/2023

THIRD FLOOR (3 EAST)

127.3 SQ / 12,730 SF

TREMCO / Shay Roofing, Inc.

177126 - AlphaGuard BIO

EXP: 6/1/2038

FIRST FLOOR (1 NE)

49.6 SQ / 4,960 SF

TREMCO / Shay Roofing, Inc.

177126 - AlphaGuard BIO

EXP: 6/1/2038

FIRST FLOOR (PEC)

54 SQ / 5,400 SF

Missouri Builders Service, Inc.

AB#1211925 - Carlisle: Golden Seal

EXP: 1/30/2027

FIRST FLOOR (1 NW-B)

85.2 SQ / 8,520 SF

TREMCO / Shay Roofing, Inc.

177126 / 177676 - AlphaGuard BIO

EXP: 6/1/2038

THIRD FLOOR (3 WEST)

126.2 SQ / 12,620 SF

TREMCO / Shay Roofing, Inc.

177676 - AlphaGuard BIO

EXP: 5/31/2038

THIRD FLOOR (ICU)

124 SQ / 12,400 SF

Shay Roofing, Inc.

W7003471 - GP DensDek

EXP: 3/31/2029

FIRST FLOOR (MRI)

56.9 SQ / 5,690 SF

Watkins Roofing, Inc.

W3001777 - Centria: Fluorofinish

EXP: 7/31/2025

FIRST FLOOR (1 SW)

81 SQ / 8,100 SF

TREMCO / Shay Roofing, Inc.

177676 - AlphaGuard BIO

EXP: 5/31/2038

THIRD FLOOR (3 SOUTH)

127.4 SQ / 12,735 SF

TREMCO / Weathercraft, Inc.

173358 - AlphaGuard BIO

EXP: 11/27/2037

FIRST FLOOR (1 SE)

55.3 SQ / 5,530 SF

TREMCO / Shay Roofing, Inc.

177126 - AlphaGuard BIO

EXP: 6/1/2038

WAREHOUSE

159.7 SQ / 15,975 SF

Watkins Roofing, Inc.

589A4-11-115 - Centria

EXP: 10/1/2031

FIRST FLOOR (OR)

144.2 SQ / 14,420 SF

SIPLAST / Missouri Builders Service, Inc.

41248 - Paradiene 20 EG/30 FR

EXP: 3/16/2037

COMM. LIVING CENTER (CLC)

177.4 SQ / 17,745 SF

Watkins Roofing, Inc.

NA - Firestone: Red Shield

EXP: 11/1/2031 est.

THIRD FLOOR (ACA)

126.8 SQ / 12,675 SF

Watkins Roofing, Inc.

700371388 - Firestone: Red Shield

EXP: 11/1/2029

SECOND FLOOR (ACA)

82 SQ / 8,200 SF

-ORIGINAL-

NA - Firestone: Red Shield?

EXP: Expired

ACA SLOPING SKYLIGHTS

THIRD FLOOR (ACA DENTAL)

125.3 SQ / 12,530 SF

Watkins Roofing, Inc.

700371388 - Firestone: Red Shield

EXP: 11/1/2029

CHILLER PLANT

47.3 SQ / 4,730 SF

WATKINS

EXP: 2001

FIRST FLOOR (SOUTH)

2.8 SQ / 2,800 SF

FHC/MARANT

EXP:

FOURTH FLOOR - NW STAIRS -

PARKING GARAGE

5.4 SQ / 540 SF

CRALLO

EXP:

Floor / Roof

Elevation (Above Sea Level)

Penthouse Parapet

842 Ft 10-1/8 Inches

Penthouse Roof 837 " 9-1/8 "

Upper Penthouse

826 " 2-1/2 "

Lower Penthouse Roof 826 " 2-1/2 "

6th Floor Roof 813 " 1-1/4 "

5th Floor Roof 800 " 5-1/4 "

4th Floor Roof 787 " 9-1/4 "

ACA Penthouse Roof " "

ICU Penthouse Roof " "

3rd Floor Roof A (ACA)

3rd Floor Roof B (ACA)

3rd Floor Roof (ICU)

3rd Floor Roof 775 " 1-1/4 "

3rd Floor 762 " 5-1/4 "

2nd Floor Roof A (ACA)

762 " 5-1/4 "

2nd Floor Roof B (ACA)

762 " 5 1/4 "

2nd Floor 749 " 9-1/4 "

1st Floor Roof (O.R.)

752 " 0-5/8 "

1st Floor Roof 749 " 9-1/4 "

1st Floor 736 " 0 "

Basement Roof 736 " "

Basement 722 " 2-3/4 "

Pipe Basement Roof

722 " 2-3/4 "

Pipe Basement

715 " 2-3/4 "

Warehouse Roof " "

Chiller Plant Roof " "

FOURTH FLOOR (PH)

787' - 9 1/4"

11.9 SQ / 1,190 SF

Mays-Maune-McWard, Inc.

41064 - Centria: Fluorofinish

EXP: 11/27/2035

SECOND FLOOR (ACA PHCY)

28.5 SQ / 2,850 SF

Shay Roofing, Inc.

700380121 - Firestone:

EXP: 2/17/2030

FOURTH FLOOR - SW STAIRS -

PARKING GARAGE

2.4 SQ / 240 SF

CRALLO

EXP: NA

FOURTH FLOOR (ACA PH)

7.5 SQ / 750 SF

Watkins Roofing, Inc.

700371388 - Firestone: Red Shield

EXP: 11/1/2029

SECOND FLOOR (ACA)

74.4 SQ / 7,438 SF

Watkins Roofing, Inc.

RB159941 - Firestone: Red Shield

EXP: 12/29/2026

(Edging only, where shown)

N

SCALE: NTS

V H

A C

M O

S H

E L T

M

F i l e n a m e

R o o f

P l a n s S i t e

L a y o u t S

E P d w g

P r i n t

D a t e

S e p

Attachment "A"

AutoCAD SHX Text

SITE PLAN - ROOF PLAN

File details come from the government source that posted it. Updated .