KC-135AtomizerTestInstruction.pdf.pdf

PDF 77 KB Posted

Attached to
Universal Fuel Control Test Stand Federal contract opportunity
Solicitation number
FA8224-15-R-0013
Issued by
Department of the Air Force Materiel Command Lifecycle Management Center Hill Air Force Base

About this file

Attachment BB -- KC-135AtomizerTestInstruction.pdf

View the file

Other files for this federal contract opportunity

Other files attached to Universal Fuel Control Test Stand, newest first.
File Type Posted
Section_M_Fuels_28_January_2016.pdf PDF
pd24E87.doc DOC document
Section_L_Fuels_28_January_2016.pdf PDF
Dec3PS.pdf PDF
Amendment_0007.doc DOC document
FA8224-15-R-0013_0002.pdf PDF
F-15FuelControl_TestInstruction.pdf.pdf PDF
Questions_and_Answers__10_Aug_2015.pdf PDF
Universal_Test_Stand.doc DOC document
Questions_and_Answers_24_July_2015.pdf PDF
B252_fp2008.pdf PDF
Bldg252_TestingAreaDrawing.PDF PDF
Bldg252Pictures.pdf PDF
C-5FlowDivider_TestInstruction.pdf.pdf PDF
METCAL_TM_86_01N 1 .pdf PDF
A003_CDRL_TMCR 1 .pdf PDF
A008_DI_ATTS_80283B 1 .pdf PDF
F-16FuelPump_TestInstruction.pdf.pdf PDF
A004_DI-SESS-8100DT 1 .pdf PDF
FA8224-15-R-0013.pdf PDF
C-5AtomizerTestInstruction.pdf.pdf PDF
C-17IGV_TestInstruction.pdf.pdf PDF
C-130_FuelControl-1__TestInstruction.pdf.pdf PDF
C-17FuelAccessories_TestInstruction.pdf.pdf PDF
C-17FuelControl_TestInstruction.pdf.pdf PDF
A011_DI_ADMN_81249A 1 .pdf PDF
Robins_TM-86-01N 1 .pdf PDF
F-22TestInstruction_pdf.pdf PDF
C-130Atomizer899981TestInstruction.pdf.pdf PDF
A001_DI_MISC_8145B 1 .pdf PDF
FED-STD-313D 1 .pdf PDF
A014_DIMGMT-81842 1 .pdf PDF
A002_DI_IPSC_81488 1 .pdf PDF
C-5FuelControl_TestInstruction.pdf PDF
A005_DI_QCIC_80278B 1 .pdf PDF
F-15AtomizerTestInstruction.pdf.pdf PDF
A-10_FuelControl__TestInstruction.pdf.pdf PDF
A010_FED_STD_313D 1 .pdf PDF
A013_DIMGMT-81580 1 .pdf PDF
KC-135TestInstruction.pdf.pdf PDF
C-130Atomizer3601193TestInstruction.pdf.pdf PDF
A009_AFMETACL_TM-86-01 1 .pdf PDF
C-17FlowDivider_TestInstruction.pdf.pdf PDF
Purchase_Specification.pdf PDF
A-10AtomizerTestInstruction.pdf.pdf PDF
A007_DI_ATTS_80282B 1 .pdf PDF
F-16AtomizerTestInstruction.pdf.pdf PDF
C-130Atomizer75076TestInstruction.pdf.pdf PDF
F-15FuelFilter_TestInstruction.pdf.pdf PDF
C-130FuelControl-8__TestInstruction.pdf.pdf PDF
Show all 50

Universal Fuel Control Test Stand has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

T.O. 2G-T62T-43

Figure 5-19B. Atomizer Fitting Repair

5-58B Change 9

Figure 5-19C. Flow Test of Atomizer Fittings

Change 9 5-58C

NOTES:

3.

4.

5.

6.

8.

9.

10.

UNEVEN WEAR PATTERNS ON THE EXTERNAL SPLINE OR EXTERNAL GEAR ARE NOT ACCEPTABLE.

THE OIL RETAINER MUST BE LOCATED .13" TO .14" FROM THE EXTERNAL GEAR END AND MUST BE TIGHT.

PARTS WHICH DO NOT MEET THESE REQUIREMENTS SHOULD BE TAGGED UNSERVICEABLE AND HELD FOR

DISPOSITION AT A LATER DATE.

5-58D) Change 9 warning

d. Flow Testing.

(1) Flow test fuel nozzle (3, figure 3-28) as follows:

(a) Connect flow check fixture, ST92300 (75, figure 2-1) to a fuel manifold flow bench, 164101-100 (85, figure 2-1).

(b) Install fuel nozzle (3) in flow check fixture, ST92300.

Calibrating fluid, MIL-C-7024, type II, is toxic to eyes, skin, and respiratory tract.

Do not breathe vapors. Use in a well-ventilated area. Wear eye and skin pro-tection. Avoid use around sparks, open flame, and heated surfaces.

(c) Connect a source of calibrating fluid, MIL-C-7024, type II, at a pressure of 350 psig, 70-90°F, to fuel nozzle (3).

Minimum fuel flow must be 14-16 pph.

(d) Observe fluid spray from nozzle.

Spray must be conical, symmetrical, and free of voids and streaks. Verify that spray angle, when measured 1/2

in. downstream of nozzle, is greater than 70°.

(e) Replace fuel nozzle if it does not sat-isfactorily meet test parameters.

(2) Flow test fuel manifold (9, figure 3-28) as follows:

(a) Install filter fitting (4, figure 3-28) in fuel manifold (9).

(b) Install fuel manifold on fuel manifold flow bench, 164101-100 (85, figure 2-1) with fuel nozzles directed into the beakers provided with flow bench.

Calibrating fluid, MIL-C-7024, type II, is toxic to eyes, skin, and respiratory tract.

Do not breathe vapors. Use in a well ventilated area. Wear eye and skin pro-tection. Avoid use around sparks, open flame, and heated surfaces.

(c) Use calibrating fluid, MIL-C-7024, type II, specific gravity of 0.815, at

80°F, as test fluid. Adjust inlet fluid pressure to 145 psig. Verify that flow rate is 288-312 pph.

(d) The flow rate from each fuel nozzle shall not exceed ±4% from the average.

(e) Test all fuel nozzles. Replace fuel manifold (9, figure 3-28) if it does not satisfactorily meet test parameters.

(3) Flow test oil jet cartridge (75, figure 3-12) as follows:

(a) Using oil, grade S 150, per ASTM 2422, flow test oil jet cartridge.

NOTE

All four jets of oil jet cartridge must flow freely.

(b) Flow test at 0.3-0.5 gpm at 20 psi.

(4) Flow test atomizer fitting (4, figure 5-19A) as follows: (See figure 5-19C.

(a) Using a hydrometer, measure the specific gravity of test fluid.

NOTE

Atomizer fittings must be free of car-bon deposits or other obstructions.

Clean per paragraph 4.3.i.

(b)

( c

( d )

( e

Using a flow test bench, P/N 164101- 100, or equivalent, adjust test flow to

45.0 - 46.0 pounds per hour (pph).

With a test fluid specific gravity of 0.78, pressure shall not exceed 2 psig.

To adjust variations in test fluid flow and specific gravity, verify pres-sure in accordance with the following formula:

Pressure = Fluid Flow Specific Gravity x 1294

Repeat step b. and c. for all atomizer fittings in each liner.

Repair atomizer fitting assemblies (4, figure 5-19A) if flow test indi-cates obstruction as follows:

Remove grommet (3).

Machine off clogged atomizer tube.

Redrill fitting as shown in figure

5-19B.

Clean, blast, and wrap fitting for brazing.

Position tube and brazing onto atomizer fitting as shown in figure 5-19B.

Change 9 5-59