12_Attachment_1A_Workspace_Specs_for_Temp_Facility_Rev_03.xlsx

XLSX spreadsheet 77 KB Posted

Attached to
Temporary Facility T-2728 Federal contract opportunity
Solicitation number
FA8219-18-R-0010
Issued by
Department of the Air Force Materiel Command Lifecycle Management Center Hill Air Force Base

About this file

Attachment 1A Revision 03

View the file

Other files for this federal contract opportunity

Other files attached to Temporary Facility T-2728, newest first.
File Type Posted
12_Attachment_4_FAR_52212_2_Evaluation_Addendum_Temp_Fac_Rev_03.docx DOCX document
12_Attachment_1_Statement_of_Work_Temporary_Facility_Rev_03.docx DOCX document
FA8219-18-R-0010-0004.pdf PDF
12_Attachment_3_FAR52212-1_Instructions_Addendum_Temp_Fac_Rev_03.docx DOCX document
12_FA8219-18-R-0010-0002.pdf PDF
12_Attachment_1E_ICD_ICS_705_v1_4.pdf PDF
12_Attachment_1_Statement_of_Work_Temporary_Facility_Rev_02.pdf PDF
12_Attachment_1L_Site_Map_Temp_Facility_and_Utilities.pdf PDF
12_Attachment_1A_Workspace_Specifications_for_Temp_Facility_Rev_02.xlsx XLSX spreadsheet
12_Attachment_3_FAR_52_212-1_Instructions_to_Offerors_Addendum_Temporary_Facility_Rev_02.pdf PDF
12_Attachment_1A_Workspace_Specifications_Temporary_Facility_Rev_01.xlsx XLSX spreadsheet
12_Attachment_8_CDRL_A028_Conceptual_Design.pdf PDF
12_Attachment_1F_Air_Force_Furnishings_Commodity_Council_Contractors_Rev_01.pdf PDF
12_Attachment_8_CDRL_A112_Site_Preparation.pdf PDF
03_Vendor_Solicitation_Questions_and_Comments.xlsx XLSX spreadsheet
11_Record_of_Pre-Proposal_Conference_Sign-in.pdf PDF
12_FA821918R0010-0001.pdf PDF
12_Attachment_1_Statement_of_Work_Temporary_Facility_Rev_01.pdf PDF
12_Attachment_3_FAR_52_212-1_Instructions_to_Offerors_Addendum_Temporary_Facility_Rev_01.pdf PDF
12_Attachment_1N_Communications_Requirements.png PNG image
12_Attachment_8_CDRL_A071_Accident_Incident_Reports.pdf PDF
12_Attachment_4_FAR_52_212_2_Evaluation_Addendum_Temporary_Facility_Rev_01.pdf PDF
03_Vendor_Questions_and_Comments_Updated_09_Feb_2018.pdf PDF
12_Attachment_1A_Workspace_Specifications_for_Temporary_Facility_Final.xlsx XLSX spreadsheet
12_Attachment_6_Subcontractor_Consent_Letter.docx DOCX document
12_Attachment_1C_Hill_AFB_Civil_Engineering_Requirements.docx DOCX document
12_Attachment_1G_City_Light_Power_Service_Connection_Manual_2017_R3.pdf PDF
12_Attachment_1J_01_57_20_Environmental_Protection.pdf PDF
12_Attachment_8_CDRL_A001_Design.pdf PDF
12_Attachment_7_Past_Performance_Questionnaire.docx DOCX document
12_Attachment_1I_01_35_26_Government_Safety_Requirements.pdf PDF
12_Attachment_1F_Air_Force_Furnishings_Commodity_Council_Contract_Requirements.pdf PDF
12_FA821918R7010.pdf PDF
12_Attachment_1L_Site_Map_Temp_Facility_and_Utilities.pdf PDF
12_Attachment_1H_01_00_00_General_Requirements.docx DOCX document
12_Attachment_1E_ICD_ICS_705.pdf PDF
12_Attachment_8_CDRL_A002_Site_Preparation.pdf PDF
12_Attachment_4_FAR_52_212-2_Evaluation_Addendum_Temporary_Facility_Revised.docx DOCX document
12_Attachment_2_Wage_Determination_UT180104.pdf PDF
12_Attachment_8_CDRL_A003_Accident_Mishap.pdf PDF
12_Attachment_1B_Standards_and_Specifications_Library.docx DOCX document
12_Attachment_5_Past_Performance_Information_Form.docx DOCX document
12_Attachment_1M_Buried_Antenna_Location.pdf PDF
12_Attachment_1D_TAB_K.pdf PDF
12_Attachment_1_Statement_of_Work_Temporary_Facility_Final.docx DOCX document
12_Attachment_3_FAR_52_212-1_Instructions_to_Offerors_Addendum_Temporary_Facility_Revised.docx DOCX document
12_Attachment_1K_HAFB_Safety_Fire_Protection_Health_Specs.pdf PDF
Show all 47

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

GBSD Temporary Facility Requirements:
Total Foot Print: Not to exceed 24,530 square feet
Supports: 204 personnel
Purpose: Office space
Ceiling Height: Not less than 8' floor to ceiling
Common Area: All exterior walls and any walls adjacent to Office Space Area #1, 2, 3, 4, Video Teleconference Room, or Computer Room must be constructed to the standards defined in ICD/ICS 705Supports # of EmployeesConstruction Specifications
Entry Foyer w/ Security Desk1
Fire Alarm Panel
Double door entry from outside (w/ vindicator access)
6'x6' Security Desk w/ office chair (1 person) - Large enough to support single video monitor for surveillance of exterior security cameras, video switching box, and computer station
Sufficient power drops
Panel for exterior security cameras and Digital Video Recorder
Computer network drop, consisting of 2 strand single mode fiber optic cable mounted in a single port face plate with SC connectors and in a separate junction box two blue CAT6 cables and jacks mounted in a dual port face plate
Hinged floor crawl space access behind security desk
Hatch must be Bilco Type TER 30"x30" or Gov't approved alternative
Make flush with remaining floor and use same flooring type over hatch
Wall mounted cubby storage for electronic devices (i.e., cell phones)
150 individual cubbies with individual access to each cubby (purpose is to store cell phones and electronic devices)
Single security door access to work area hallway (w/ vindicator access)ICD/ICS 705
Hallway provides access to Office Space Areas #1, #2, #3, #4, Video Teleconference Room, Computer Lab and Communications Room, as described belowICD/ICS 705
Break Room w/ Kitchenette - may adjoin exterior wall w/ windows8
Lower Cabinets appropriate for the space
Upper cabinets appropriate for the space
Laminate Counter top to cover all lower cabinets
Double basin sink w/ hot and cold running water and drain (high water faucet for filling coffee maker or large pots)
Area for 2 large refrigerators
Area for 2 large coffee makers
Area for 2 Microwaves
Cabinetry dedicated to store and sell snacks (e.g., upper display cabinet, small counter top, lower storage cabinets) - this can be suitable piece of furniture or a built in.
Appropriate room lighting
Vinyl flooring throughout
Laminate backsplash (counter top to upper cabinets)
Seating for up to 8 people
Water Fountain with Bottle Filler (Ideally located in vicinity of breakroom)
Male Bathroom (IAW: OSHA Standards 1910.141(c)(1)(i), Table J-1) Counter top w/ 3 sink basins installed and Mirror entire length of counter; 3 urinals; and 4 toilet stalls (Water closets)UFC 1-200-01
Female Bathroom (IAW: OSHA Standards 1910.141(c)(1)(i), Table J-1) Counter top w/ 3 sink basins and mirror entire length of counter; and 4 toilet stalls (Water closets)UFC 1-200-01
Janitor/Cleaning Supply ClosetN/A
Deep basin sink (or functionally similar) w/ hot and cold running water and drain (needed to fill and empty mop buckets)
4 shelves along one side wall for cleaning supplies
Appropriate switched lighting
Storage area for up to 30 temporary duty laptop computers and accessories, installed in single power and network rack systems (120VAC power and fiber optic network drops).
Office Space Area #1: Entire room constructed to ICD/ICS 705 Standards; No windows on exterior walls; access from main hallway100ICD/ICS 705
Open air office space for 94 employees (carpeted w/ appropriate ceiling lighting, fire detection and suppression, and HVAC to code)94
Each employees cube shall be monolithic panel, 6'x6' staff cube (efficiency), w/ power to all panels
Cubicles shall be grouped into sets of 4 - to the maximum extent possible
Each set of 4 cubicles will have a single entry point (sized to code) with entry from a hall space (sized to code)
Each cubical work space shall contain:
Corner style desk space (appropriate to size of their cubical)
2 each 3-drawer filing cabinets (attached under desk top)
Over-desk storage cabinets (appropriate to size of their cubical)
Black, swivel/tilt mesh mid-back task chair, with fixed cantilevered arms
Switched lighting under the over-desk storage cabinets
Sufficient electrical outlets to support 3 computers, 2 monitors, 1 telephone, 1 KVM Switch, and cubical lights, plus one additional double outlet
6 strand single mode fiber optic cable installed in a single 3 port face plate with SC connectors per location and in a separate junction box two blue CAT 6 cables and jacks mounted in a two port face plate per location
Centrally located workspace for three (3) Network Printers, w/ 1 power and fiber optic network drop per printer
Centrally located workspace for one (1) 5-drawer safe (18"x28" - weighs 1,000 lbs. loaded) and 1 paper shredder (20"x27")
6 individual offices (carpeted w/ appropriate ceiling lighting and HVAC to code)6
Supervisor’s office shall be a stackable panel, 8'x10' manager cube, with power on all panels, and with office height panels (76"-81") with door.
Each supervisor’s office shall be furnished with freestanding "U" shaped desk, with 24" wide storage tower with shelves
Chairs shall be black, swivel/tilt mesh mid-back task chair, with fixed cantilevered arms
Sufficient electrical
6 strand single mode fiber optic cable installed in a single 3 port face plate with SC connectors per location and in a separate junction box two blue CAT 6 cables and jacks mounted in a two port face plate per location
Intrusion Detection System (IDS) Panel (throughout area #1) - tied back to communication room (CER)
IDS consists of door intrusion and motion sensors tied to IDS panel within room
Vindicator Access Control on area #1 entry door - tied back to Communication Room (CER)
Centrally located workspace for two (2) Network Printers, w/ 1 power and fiber optic network drop, and 1 power and fiber optic network drop
Conference Room #1:18ICD/ICS 705
1 Conference Room Table for 8 (office chairs) with seating around perimeter wall for 10 additional persons
2 strand single mode fiber optic cable installed in a single port face plate with SC connectors and a separate junction box two blue CAT 6 cables and jacks mounted in a two port face plate, at conference room table
Computer work stations and desk with one (1) 60" wall mounted monitor, Power outlet, and 1 fiber optic video line from computer work station to monitor
Teleconference phone (located on conference table) w/ 1 fiber optic network drop in close proximity of conference table to allow connectivity.
Fire detection and suppression system (to code)
Multi-zoned lighting throughout with dimming capability
HVAC to Code
Conference Room #2:18ICD/ICS 705
1 Conference Room Table for 8 (Office chairs) with seating around perimeter wall for 10 additional persons
2 strand single mode fiber optic cable installed in a single port face plate with SC connectors and in a separate junction box two blue CAT 6 cables and jacks mounted in a two port face plate, at conference room table
Computer work stations and desk with one (1) 60" wall mounted monitor, Power outlet, and 1 fiber optic video line from computer work station to monitor
Teleconference phone (located on conference table) w/ 1 fiber optic network drop in close proximity of conference table to allow connectivity.
Fire detection and suppression system (to code)
Multi-zoned lighting throughout with dimming capability
HVAC to Code
Office Space Area #2: Entire room constructed to ICD/ICS 705 Standards; No windows on exterior walls; access from main hallway50ICD/ICS 705
Open air office space for 48 employees (carpeted w/ appropriate ceiling lighting, fire detection and suppression, and HVAC to code)48
Each employees cube shall be monolithic panel, 6'x6' staff cube (efficiency), w/ power to all panels
Cubicles shall be grouped into sets of 4 - to the maximum extent possible
Each set of 4 cubicles will have a single entry point (sized to code) with entry from a hall space (sized to code)
Each cubical work space shall contain:
Corner style desk space (appropriate to size of their cubical)
2 each 3-drawer filing cabinets (attached under desk top)
Over-desk storage cabinets (appropriate to size of their cubical)
Black, swivel/tilt mesh mid-back task chair, with fixed cantilevered arms
Switched lighting under the over-desk storage cabinets
Sufficient electrical outlets to support 3 computers, 2 monitors, 1 telephone, 1 KVM Switch, and cubical lights, plus one additional double outlet
6 strand single mode fiber optic cable installed in a single 3 port face plate with SC connectors per location and in a separate junction box two blue CAT 6 cables and jacks mounted in a two port face plate per location
Centrally located workspace for three (3) Network Printers, w/ 1 power and fiber optic network drop per printer
Centrally located workspace for one (1) 5-drawer safe (18"x28" - weighs 1,000 lbs. loaded) and 1 paper shredder (20"x27")
2 individual offices (carpeted w/ appropriate ceiling lighting and HVAC to code)2
Supervisor’s office shall be a stackable panel, 8'x10' manager cube, with power on all panels, and with office height panels (76"-81") with door.
Each supervisor’s office shall be furnished with freestanding "U" shaped desk, with 24" wide storage tower with shelves
Chairs shall be black, swivel/tilt mesh mid-back task chair, with fixed cantilevered arms
Sufficient electrical
6 strand single mode fiber optic cable installed in a single 3 port face plate with SC connectors per location and in a separate junction box two blue CAT 6 cables and jacks mounted in a two port face plate per location
Intrusion Detection System (IDS) Panel (throughout area #2 - tied back to communication room (CER)
IDS consists of door intrusion and motion sensors tied to IDS panel within room
Vindicator Access Control on area #2 main entry door - tied back to Communication Room (CER)
Centrally located workspace for two (2) Network Printers, w/ 1 power and fiber optic network drop, and 1 power and fiber optic network drop
Office Space Area #3: Entire room constructed to ICD/ICS 705 Standards; No windows on exterior walls; access from main hallway - must be adjacent to Workspace #435ICD/ICS 705
Open air office space for 33 employees (carpeted w/ appropriate ceiling lighting fire detection and suppression, and HVAC to code)33
Each employees cube shall be monolithic panel, 6'x6' staff cube (efficiency), w/ power to all panels
Cubicles shall be grouped into sets of 4 - to the maximum extent possible
Each set of 4 cubicles will have a single entry point (sized to code) with entry from a hall space (sized to code)
Each cubical work space shall contain:
Corner style desk space (appropriate to size of their cubical)
2 each 3-drawer filing cabinets (attached under desk top)
Over-desk storage cabinets (appropriate to size of their cubicle)
Black, swivel/tilt mesh mid-back task chair, with fixed cantilevered arms
Switched lighting under the over-desk storage cabinets
Sufficient electrical outlets to support 2 computers, 4 monitors, 1 telephone, 1 KVM Switch, and cubical lights) plus one additional double outlet
6 strand single mode fiber optic cable installed in a single 3 port face plate with SC connectors per location and in a separate junction box two blue CAT 6 cables and jacks mounted in a two port face plate per location
Centrally located workspace for three (3) Network Printers, w/ 1 power and fiber optic network drop per printer
Centrally located workspace for one (1) 5-drawer safe (18"x28" - weighs 1,000 lbs. loaded) and 1 paper shredder
2 individual offices (carpeted w/ appropriate ceiling lighting and HVAC to code)2
Supervisor’s office shall be a stackable panel, 8'x10' manager cube, with power on all panels, and with office height panels (76"-81") with door.
Each supervisor’s office shall be furnished with freestanding "U" shaped desk, with 24" wide storage tower with shelves
Chairs shall be black, swivel/tilt mesh mid-back task chair, with fixed cantilevered arms
Sufficient electrical
6 strand single mode fiber optic cable installed in a single 3 port face plate with SC connectors per location and in a separate junction box two blue CAT 6 cables and jacks mounted in a two port face plate per location
Intrusion Detection System (IDS) Panel (throughout area #3) - tied back to communication room (CER)
IDS consists of door intrusion and motion sensors tied to IDS panel within room
Vindicator Access Control on area #3 entry door - tied back to Communication Room Switch
Centrally located workspace for two (2) Network Printers, w/ 1 power and fiber optic network drop per printer
Office Space Area #4: Entire room constructed to ICD/ICS 705 Standards; No windows on exterior walls; access from main hallway - must be adjacent to Workspace #315ICD/ICS 705
Open air office space for 14 employees (carpeted w/ appropriate ceiling lighting fire detection and suppression, and HVAC to code)14
Each employees cube shall be monolithic panel, 6'x6' staff cube (efficiency), w/ power to all panels
Cubicles shall be grouped into sets of 4 - to the maximum extent possible
Each set of 4 cubicles will have a single entry point (sized to code) with entry from a hall space (sized to code)
Each cubical work space shall contain:
Corner style desk space (appropriate to size of their cubical)
2 each 3-drawer filing cabinets (attached under desk top)
Over-desk storage cabinets (appropriate to size of their cubical)
Black, swivel/tilt mesh mid-back task chair, with fixed cantilevered arms
Switched lighting under the over-desk storage cabinets
Sufficient electrical outlets to support 3 computers, 2 monitors, 1 KVM Switch, and cubical lights) plus one additional double outlet
6 strand single mode fiber optic cable installed in a single 3 port face plate with SC connectors per location and in a separate junction box two blue CAT 6 cables and jacks mounted in a two port face plate per location
Centrally located workspace for three (3) Network Printers, w/ 1 power and fiber optic network drop per printer
Centrally located workspace for one (1) 5-drawer safe (18"x28" - weighs 1,000 lbs. loaded) and 1 paper shredder (20"x27")
1 individual office (carpeted w/ appropriate ceiling lighting and HVAC to code)1
Supervisor’s office shall be a stackable panel, 8'x10' manager cube, with power on all panels, and with office height panels (76"-81") with door.
Each supervisor’s office shall be furnished with freestanding "U" shaped desk, with 24" wide storage tower with shelves
Chairs shall be black, swivel/tilt mesh mid-back task chair, with fixed cantilevered arms
Sufficient electrical
6 strand single mode fiber optic cable installed in a single 3 port face plate with SC connectors per location and in a separate junction box two blue CAT 6 cables and jacks mounted in a two port face plate per location
Intrusion Detection System (IDS) Panel (throughout area #3) - tied back to communication room (CER)
IDS consists of door intrusion and motion sensors tied to IDS panel within room
Vindicator Access Control on area #3 entry door - tied back to Communication Room Switch
Video Teleconference Room: Entire room constructed to ICD/ICS 705 Standards; access from main hallway; must be adjacent to Computer Lab24ICD/ICS 705
1 Conference Room Table for 8, with seating around the walls for 16 additional persons
Computer workstation w/ 9 fiber optic computer network cable drops
Teleconference phone (located on conference table) w/ 1 fiber optic network drop in close proximity of conference table to allow connectivity.
Intrusion Detection System (IDS) Panel (inside room); can be tied with computer lab - all tied back to the Comm Rm (CER)
IDS consists of door intrusion and motion sensors tied to IDS panel within room
Vindicator Access Control on entry door - tied back to Communication Room Switch
Video Teleconference Equipment with two (2) 60" wall mounted monitors and one overhead projector.
Multi-zoned lighting throughout room with dimming capability
Fire detection and suppression system (to code)
Computer Lab: Entire Room constructed to ICD/ICS 705 Standards; access from main hallway; must be adjacent to Video Teleconference Room.3 employees and 20 additional workstationsICD/ICS 705
Open air office space for 3 employees (carpeted w/ appropriate ceiling lighting fire detection and suppression, and HVAC to code)3
Each employees cube shall be monolithic panel, 6'x6' staff cube (efficiency), w/ power to all panels
Each cubical work space shall contain:
Corner style desk space (appropriate to size of their cubical)
2 each 3-drawer filing cabinets (attached under desk top)
Over-desk storage cabinets (appropriate to size of their cubical)
Black, swivel/tilt mesh mid-back task chair, with fixed cantilevered arms
Switched lighting under the over-desk storage cabinets
Sufficient electrical outlets to support 3 computers, 2 monitors, 1 KVM Switch, and cubical lights, plus one additional double outlet
6 strand single mode fiber optic cable installed in a single 3 port face plate with SC connectors per location and in a separate junction box two blue CAT 6 cables and jacks mounted in a two port face plate per location
20 additional independent work spaces (these do not have to contain cubicle furniture - 6 foot long work desks will suffice) - Each work space shall contain:20
5 desktop computers, 2 monitors, 1 keyboard, 1 mouse, 1 KVM switch
Dividers between each work station
Black, swivel/tilt mesh mid-back task chair, with fixed cantilevered arms (1 chair per work station)
6 strand single mode fiber optic cable installed in a single 3 port face plate with SC connectors per location and in a separate junction box two blue CAT 6 cables and jacks mounted in a two port face plate per locations
Appropriate power outlets for all equipment
Intrusion Detection System (IDS) Panel (inside room); can be tied with video teleconference room - all tied back to the Comm Rm (CER)
IDS consists of door intrusion and motion sensors tied to IDS panel within room
Vindicator Access Control on entry door - tied back to Communication Room Switch
Centrally located workspace for six (6) Network Printers, w/ 1 power and fiber optic network drop per printer
Centrally located workspace for one (1) 5-drawer safe (18"x28" - weighs 1,000 lbs. loaded) and 1 paper w/optical shredder (20"x27")
Main Communications Room (CER): ICD/ICS 705; centrally located to provide direct network access to each workspace (no pass-throughs) Reference Tab K - 75 ABW/SC, Telecommunications Installation Criteria for Facility Design and RenovationN/AICD/ICS 705
Room shall be sized to accommodate 3 equipment racks installed side by side and shall be placed to provide front and rear access with a minimum of 36" clearance front and back
Racks shall be 19" X 7' two post racks, racks shall have 6" vertical cable managers located on the left and right sides, front and back, and seismically braced
Racks shall be grounded; shall have one (1) quad-plex 120 VAC, 60Hz, 1 phase electrical outlets and two (2) 208 VAC, 60Hz, 1 phase electrical outlets per rack and installed on the back side bottom of each rack
Provide, install, terminate, test and label 12 strand single mode fiber optic cable in a rack mounted fiber patch panel with SC connectors from the CER to a rack mounted fiber patch panel in each TR
Provide, install, terminate, test and label a 25 pair house cable on a 24 port rack mounted CAT 6 patch panel from the CER to a 24 port rack mounted CAT 6 patch panel in each TR
5 SwitchesThe Government shall provide and install required switchesDELETED
5 TACLANEs The Government shall provide and install required TACLANESDELETED
Intrusion Detection System (IDS) Panel (inside room) - tied back to communication room (CER)
IDS consists of door intrusion and motion sensors tied to IDS panel within room
Vindicator Access Control on entry door - tied back to Communication Room Switch
Fire detection and suppression system (to code)
Mechanical/Electrical: Secure exterior entry - entire room constructed to ICD/ICS 705 standards; mechanical lock on exterior door.N/AICD/ICS 705
Design to support all required mechanical systems
Design to support all required electrical systems
Design to support all required HVAC systems with capabilities to emergency shut down for Shelter-In-Place requirements
Fire detection and suppression (to code)
Exterior Camera System: Day, night, and all weather security cameras; 360 degrees around outside of facility; mounted to the building; linked to security desk in foyer
Clear line of sight to all entrances, emergency exits, and door ways.
Exterior Communications CablingN/AN/A
Provide, install, terminate, test and label 24 strand single mode fiber optic cable in a rack mounted fiber patch panel with SC connectors from MH 19011-30 to CER
Provide, install, terminate, test and label 50 pair cable in a backboard mounted BET from MH 19011-30 to CER. From BET provide, install, terminate, test and label a 50 pair house cable in a CAT 6 rack mounted patch panel
Provide and install 2, 4" conduit from MH 19011-30 to CER. Within one of the 4" conduits install 4, 1" inner-ducts
Provide, install, terminate, test and label a 300 pair cable in Bldg 1214
Provide, Install, terminate, test and label 288 strand single mode fiber from MH 19011-30 through MH19011-29, MH19011-28 to Bldg 1214. Unspliced cable shall be tested using OTDR
Splice 24 strand single mode fiber in MH 19011-30 to 288 strand fiber
Splice 50 pair cable in MH 19011-30 to 300 pair cable
Amendment 0004 changes incorporated:
Lines: 14, 56, 64, 71, 79, 98, 106, 124, 132, 150, 158, 184, and 189 - Amended to clarify computer drop requirements.
Lines: 65, 67, 133, 159, 167, 191, and 205 - Amended to clarify reference to "CER."
Lines: 73 and 87 - Deleted fiber requirement for teleconference phones
Lines: 198-204 - Amended to provide clarification of requirements
Lines: 220-227 - Added to define exterior comm cabling requirements