Additional Questions.xlsx

XLSX spreadsheet 77 KB Posted

Attached to
Power Conditioning and Continuation Interfacing Equipment RFP Federal contract opportunity
Solicitation number
FA821723R5000
Issued by
Department of the Air Force Materiel Command Lifecycle Management Center Hill Air Force Base

View the file

Other files for this federal contract opportunity

Other files attached to Power Conditioning and Continuation Interfacing Equipment RFP, newest first.
File Type Posted
USSF-SPOC Buckley 442 Utility (29 Apr 22).docx DOCX document
USSF-SPOC Buckley 1030 (19 Oct 22).docx DOCX document
USSF-SPOC Buckley 442 Tech (1 Apr 22).docx DOCX document
USSF-SPOC Buckley 433 (6 Oct 22).docx DOCX document
USSF-SPOC Buckley 1028 (21 Nov 22).docx DOCX document
USSF-SPOC Buckley 445 (1 Apr 22).docx DOCX document
01 Amendment.docx DOCX document
USSF-SPOC Buckley 444 (1 Apr 22).docx DOCX document
USSF-SPOC Buckley 731 (28 Oct 22).docx DOCX document
REVISED_Section L_PCCIE 15June2023_Final.pdf PDF
EMPM Questions_PCCIE Answers.xlsx XLSX spreadsheet
00 Amendment.docx DOCX document
FA821723R5000_15June2023.pdf PDF
REVISED_PCCIE II_TEP Matrix_15June23_Final.xlsx XLSX spreadsheet
REVISED_PCCIE_PWS_15June23_Final.pdf PDF
CDRL-0010-Program Management Reviews.pdf PDF
CDRL-0016-UPS Service Report.pdf PDF
CDRL-0005 Key Personnel.pdf PDF
CDRL-0007-Progress Status Internet Database.pdf PDF
CDRL-0002 Quality Control Program.pdf PDF
CDRL-0009-Monthly Conference Report.pdf PDF
CDRL-0025-Contractors status and managemnt report-PM.pdf PDF
CDRL-0027-Small Business Subcontracting Plan.pdf PDF
CDRL-0011 Emergency Telephone Number Identification.pdf PDF
CDRL-0006 Overseas and identified OCONUS Travel.pdf PDF
CDRL-0014 Contract Exit Criteria.pdf PDF
CDRL-0024 Repair and Sustainment Services.pdf PDF
CDRL-0026-Contractors status and managemnt report-EM.pdf PDF
CDRL-0015 Inventory Spare Part Kits.pdf PDF
CDRL-0022 EM Extended Repair Notice-Parts....pdf PDF
CDRL-0023 Extenuating Circumstances-Delay.pdf PDF
CDRL-0013 Plan of Action-Escalation Plan.pdf PDF
CDRL-0001 Associate Contractor Agreements.pdf PDF
CDRL-0020 Strength of Support Report.pdf PDF
CDRL-0004 Workers Health and Safety.pdf PDF
CDRL-0008-UPS Service Report.pdf PDF
CDRL-0017 Emergency Telephone Assist.pdf PDF
CDRL-0012 Service Reports and Delivery.pdf PDF
CDRL-0019 Repair Proposal.pdf PDF
CDRL-0021 Summary of Repair Efforts.pdf PDF
CDRL-0018 EM Notification Content.pdf PDF
FA821723R5000_15May2023.pdf PDF
PCCIE_QASP_02June2022_Final.pdf PDF
CDRL Package.pdf PDF
PCCIE II_TEP Matrix_04April23_Final.xlsx XLSX spreadsheet
Section M_PCCIE_20Dec2022.pdf PDF
PCCIE_PWS_May 2023 Final.pdf PDF
Section L_PCCIE 20Dec2022.pdf PDF
Appendix C -SAFETY 05Aug22 Final.pdf PDF
SOFA Clause 2022.pdf PDF
Show all 50

Power Conditioning and Continuation Interfacing Equipment RFP has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

Question No.RFP AttachmentSectionQUESTION FOR SUBMISSION
1REVISED_Cross+Reference+Matrix_PCCIE_2023Contract DocumentationPlease confirm that the items listed under the "Contract Documentation" section should be acknowledged as received by offerors, but that we are not to submit these items with our proposal.Contractor does not need to submit back the Contract Documentation on the Cross Reference Matrix
2PWSContract Clauses, pg 19 of 52Considering that not all repair / replacement parts and/or batteries may be BAA or TAA compliant, and since there is a 30 day repair or replenishments requirement in the PWS, will there be an accelerated process for obtaining waivers from BAA/TAA when those instances arise?This will be addressed on a case-by-case basis
3PWS12.3.3Root Cause Analysis (RCA) is the process of discovering the root causes of problems in order to identify appropriate solutions. RCA assumes that it is much more effective to systematically prevent and solve for underlying issues rather than just treating the evident problem or symptom. Root cause analysis can be performed with a collection of principles, techniques, and methodologies that can all be leveraged to identify the root causes of an event or trend. Looking beyond superficial cause and effect, RCA can show where processes or systems failed or caused an issue in the first place. Unless obvious external issues are the cause this may require an indepth review of trend analysis of events leading up to, at the point of an event and the time that followed to properly diagnose the true Root Cause. PWS 12.3.3 (g.) requires a one sentence summary of the failure's root cause. Can you please clarify this requirement is for a short summary of the work performed and the technician's suspected Root Cause for the failure and not a complete RCA?Root Cause is in Section 12.4.3 i.

We corrected the PWS to state. A summary of the failure's etc….

4PWS15.7.dPlease confirm that per PWS 15.7.d, if the PM visit requires the UPS to go into bypass, the contractor shall communicate with the site POC that a government employee will place the UPS into bypass mode prior to the technician arriving to the site. It is our assumption that the DOD customer does not have any experience or knowledge in the area and shall not have that duty placed upon them.The PWS was updated to state: a.The contractor shall manipulate the switchgear and they will not be held liable for any downstream damage assuming correct procedures are followed. The contractor may require the site to fill out a release of liability form for any downstream equipment damage. Regardless of who manipulates the switchgear, there is risk of damage to critical equipment downstream. There is no increase in risk regarding who performs the switchgear manipulation, however, it is a risk that we as the government must assume.
5Section LC.2.4Can you provide the make, model and quantity for all connected batteries in the awarded task section of the PWS? Without this information, we will have to make assumptions, such as Quantity, make, model and process for completing the response.Will attach site sheets
6Section LC.2.4Can the serial, model #'s, and Quantity be provided for all Auxiliary / Ancillary equipment in the awardable task section of the PWS? Without this information, we will have to make assumptions, such as Quantity, make, model and process for completing the response.Will attach site sheets

SOLICITATION NO. N40084-12-R-6500 PROJECT TITLE/LOCATION: GOVERNMENT PRE PROPOSAL INQUIRY FORM

File details come from the government source that posted it. Updated .