Attach 3 Architectural Compatibility Plan.pdf

PDF 6 MB Posted

Attached to
Multiple Award Construction Contract (MACC) Federal contract opportunity
Solicitation number
FA4497-12-R-0002
Issued by
Department of the Air Force Air Mobility Command

About this file

Attachment 3 Architectural Compatibility Plan

View the file

Other files for this federal contract opportunity

Other files attached to Multiple Award Construction Contract (MACC), newest first.
File Type Posted
Font Size.docx DOCX document
Title Block.dwg DWG drawing
Amend 0002.pdf PDF
Attach 1 DAFB Specs —
Exhibit 1 SOW Bldg 711 9 Mar 12.pdf PDF
Responses to Questions-5A.pdf PDF
Responses to Questions-5.pdf PDF
Alter Latrines.pdf PDF
Rpr Doors.pdf PDF
Pipe Layout Heating Sys.pdf PDF
Renovate Latrines Hanger Fac 711.pdf PDF
Rpr Maintenace Stands.pdf PDF
Eletrical Riser Diagram Door Wiring.pdf PDF
W5104.pdf PDF
W4698_981011_Install New Equipment Mechanical Room Facility.pdf PDF
Maintain Hangar Floors.pdf PDF
Rpr Doors Main Hanger.pdf PDF
Rpr Hangar Doors.pdf PDF
Rpl Hanger Door Stops.pdf PDF
Modify Lighting.pdf PDF
Local Control Panel Wiring Diagram.pdf PDF
Rpr HVAC System.pdf PDF
Const Fuel Sys Maint. Dock.pdf PDF
Modification Of Receptacles.pdf PDF
RprHangar Doors Two Facs.pdf PDF
Rpr Heating Sys.pdf PDF
Rpr Hangar Shops.pdf PDF
Rpr Doors.pdf PDF
New Roof.pdf PDF
Rpr Doors.pdf PDF
Rpr Heat Air Cond Maint Hanger Fac.pdf PDF
W5070.pdf PDF
Responses to Questions-4.pdf PDF
as builts - BUILDING 711- 4 nov 05 acad 2000 lt.dwg DWG drawing
Site Visit Minutes- 23 Feb.pdf PDF
Site Visit Minutes- 28 Feb.pdf PDF
Amend 0001.pdf PDF
Attach 6 —
Responses to Questions-3.pdf PDF
Responses to Questions-2.docx DOCX document
Attach 6 —
Site Visit Information.pdf PDF
Responses to Questions- 1.pdf PDF
Attach 1 DAFB Specs —
FA4497-12-R-0002.pdf PDF
Exhibit 1 Seed Project Docs.pdf PDF
Attach 5 Climate Data.pdf PDF
Attach 4 Ext Color Scheme.pdf PDF
Attach 2 Local Design Guide —
Attach 6 Past Perf Survey.pdf PDF
Show all 50

Multiple Award Construction Contract (MACC) has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Dover Air Force Base architectural compatibility plan an architecture of community

1011592267A Typewritten Text

1011592267A Typewritten Text

FA4497-12-R-0002

Attachment 3

Vision

An Architecture of Community is the long-range vision for Dover Air Force Base. This is a vision of excellence displayed in a high-quality corporate image for facilities, the landscape, and the environment. Its architecture is a language understated by post-modern and neo-classical form that remains uncluttered in a well-developed landscape setting.

Architectural compatibility and Community can be achieved by understanding the vision for the base and by refining its design vocabulary. Successful examples of high quality facili-ties, landscaping, and streetscapes are presented in this Architectural Compatibility Plan (ACP). These examples depict the design standards that will ensure compatibility and achieve the vision of excellence.

1table of contents table of contents

Introduction

Design Standards

Basewide

Buildings

Wall Systems

Roof Systems

Entrances

Windows and Doors

Ancillary Structures

Screens and Enclosures

Landscaping

Walkways and Paths

Roads

Parking

Signs

Site Furnishings

Lighting

Utilities………

Flightline / Industrial

Family Housing

Implementation

Appendices

Materials and Colors.................................A1

Exterior Color Applications.....................A2

Landscape Materials.................................A3

Related Plans and Guidelines ...............A4

ACRB Checklist ........................................A5

Index.............................................................A6

Notes............................................................A7

2 architectural compatibility plan - Dover Air Force Base

The Architectural Compatibility Plan (ACP) defines a clear design vo cab u lary to be used throughout the base, providing specific standards for all aspects of exterior design. Compatible architecture is ac com plished with similar buildings, using common design forms, details, materials, site features, and streetscapes.

Quality and compatibility are achieved through creat-ing a unified visual environment that is based on an Architecture of Community, similar to a campus or small town. The principal design goal is to direct de vel op ment at Dover AFB toward a livable, attractive, and cohesive installation.

The ACP provides the design standards that will help to build compatible facilities and a quality environment.

Implementation of the standards will result in the creation of community.

introduction

Purpose

The purpose of the ACP is to define de-sign standards for buildings, site devel-opment, and streetscapes that serve to integrate the visual character throughout the base.

The ACP will help ensure consistent quality design decisions by commanders, planners, architects, engineers, mainte-nance staff, and residents. It promotes clear, concise communication between the Dover AFB personnel and design professionals.

This plan applies to self-help initiatives, small projects, and operations and maintenance activities as well as large construction efforts.

The ACP is referenced from and supports the Dover AFB General Plan as a key component plan.

introduction tion section defines methods to facilitate the coordination and approval of design submittals.

Finally, the Appendices provide addi-tional information including an index; a list of building materials, site amenities, colors, and landscape materials; and a checklist for the ACRB and project personnel. Use the Appendices in con-junction with the general text of the ACP as a quick reference to specific materials and color specifications.

A poster is available upon request that displays photographic examples of the Dover AFB community.

How to Use This Plan

The ACP defines three distinct archi-tectural settings: Basewide, Flightline / Industrial, and Family Housing (see the map below).

General and specific design standards for all buildings are included in the Basewide setting. Basewide standards shall be applied to all projects. When a project is located in the Flightline / Indus-trial, or Family Housing setting more specific standards from those Sections of the ACP shall be applied.

The Implementation Section of the ACP outlines key elements to ensure success in designing and constructing excellent facilities. It discusses the traditional design process, highlights the impor-tance of site analysis, and describes the role of the Architectural Compatibility Review Board (ACRB). The implementa-

Basewide

Flightline / Industrial

Family Housing

Architectural Settings

4 architectural compatibility plan - Dover Air Force Base design stan dards

Design standards for buildings and supporting elements are outlined in this section. These standards encourage architectural compatibility using common forms, materials, colors, and architectural details.

The first priority is to achieve architectural compatibility for Dover Air Force Base as a whole. The second priority is compatibility within an ar chi tec tur al setting or sub-area. Outstanding designs for individual buildings or facilities are the third priority. The goal is to design excellent facilities that satisfy all of these priorities.

5design standards - basewide

Dover AFB has established a direction towards architectural unity. The existing architecture depicts a predominant materials palette and a consistency of material detailing. The following design standards are applicable to the entire installation, to both host and tenant organizations.

Site planning and site development issues contribute significantly to the architectural context. Building setbacks and the scale and definition of space are as fundamental to creating architectural compatibility as consistent facade designs. Develop exterior spaces to promote pedestrian use and activity and to connect buildings and the land-scape. Use the landscape with other visual elements to create greater continuity.

BUILDINGS

Achieving compatibility among buildings is essential in creating an Architecture of Community. Develop facilities with a common design theme and character to enhance architectural compatibility.

Unity is the goal, not conformity.

Style / Form

Place buildings at grade with the entrance expressed as a feature.

Emphasize horizontal proportions on building elements.

Rectangular elements are the stan-dard for major building masses. Use clean, simple, contemporary forms and avoid curves or angular elements in plan.

Use brick as the predominant wall material with stucco accents com-bined with sloped metal roofing and pronounced eaves with moderate overhangs.

Develop a strong relationship be-tween buildings and exterior spaces.

Articulate building facades to create areas of shade and shadow.

Scale / Massing

Reduce the monumental appearance of large structures by developing smaller massing components.

Break up the mass of large structures to allow for sloped roofs to the maxi-mum extent.

Combine functions whenever pos-sible to avoid a proliferation of small independent structures.

Existing Buildings

Match the existing materials for addition / alteration projects unless a significant change to the exterior envelope is included.

Whenever possible bring existing facilities into compliance.

basewide

6 architectural compatibility plan - Dover Air Force Base

WALL SYSTEMS

Walls provide the principal details and architectural features for buildings that contribute significantly to the character of the base. Limit the pallet of materials maintain consistency in material and color to reduce visual clutter caused by too much diversity.

Brick

Use Dover Tan standard-size face brick in a running bond pattern with tooled concave joints as the standard.

Use header, rowlock, and soldier coursing with corbelling, relief or other accents to create shadow lines.

Brick may be used when appropriate for lintels and sills.

Promote the use of relief in brick surfaces creating shadow lines.

Conceal expansion joints with down-spouts or locate them at transitions in the wall such as at pilasters or reveals.

Use natural colored Portland cement mortar.

Efflorescence in masonry work is unacceptable. Measures must be provided to prevent it.

Stucco

Use stucco for subtle accents to brick and as the wall finish for renovations when brick is not feasible.

Tan is the primary color for stucco.

Dark tan stucco may be used as an accent on stucco walls with ACRB approval.

Sand finish is the standard.

Use a three-coat, cement based stucco. Using of final finish of synthetic hardcoat over the scratch and brown coats is acceptable.

Coordinate joint patterns with relief in the wall such as at pilasters to minimize their presence.

Protect stucco from damage by lawn maintenance equipment with land-scape buffer or mow strip.

7design standards - basewide

Architectural Precast

Precast is appropriate for lintels, sills, water tables, belt courses, and friezes.

Natural Portland Cement is the stan-dard color.

Use precast sparingly to ensure that brick remains the prominent material.

Other Materials

Distinguish the base from the facade with detailing and / or a change in material.

Limit the use of pre-finished metal wall panels to industrial / flightline facilities and special applications only with ACRB approval.

Factory finish all exposed metals with a powder-coat application such as Kynar-500.

Joint sealants shall match the color of the darker adjacent surfaces.

When adjacent surfaces are the same color use a 10% darker joint sealant in the same color.

Accents / Detailing

High-visibility facilities shall dem-onstrate a greater application of detailing.

Use accents such as horizontal band-ing, medallions, and friezes to high-light entries and to enliven facades.

Use joints, reveals, recessed panels, and expressed pilasters to break up flat facades and add visual interest.

Wall Components

Organize and coordinate placement of all mechanical, electrical, lighting, communication, and other building components, including downspouts and vents, into the overall architec-tural design.

Do not expose conduits, cables, and piping on walls.

All gas meters, fire bells, vents, lou-vers, and electrical / communication boxes shall match the wall surface color on which the equipment is mounted.

Wall-mounted light fixtures shall be coordinated with the architectural features.

8 architectural compatibility plan - Dover Air Force Base

ROOF SYSTEMS

Consistency in the roof color, material, and form plays a vital role in architec-tural compatibility. Make roofs compa-rable in shape, slope, material, and color throughout the base.

General

Hipped roofs are preferred for most buildings. Gabled end walls with sloped parapets may also be used.

Open gabled elements may be used to accent entries.

Slopes shall be between 4:12 and 6:12.

Dutch-hipped roofs may be used with ACRB approval.

Do not use large overhangs. Keep overhangs proportional to the size and height of the building.

Low-sloped roofs are allowed for larger structures in combination with sloped metal roofs, or add / alt projects with ACRB approval.

Materials and Color

Use factory-finished, standing seam metal roofing on sloped roofs, with a 16-inch wide panel and a 2-inch raised standing seam.

Roofing shall be dark bronze.

Roof flashing shall match the roof material and color.

Stepped flashing at the intersection of roofs and walls shall match wall color.

Membrane roofing for low-sloped roofs may only be used with ACRB approval. A warranted minimum slope of 1/2 : 12 is required.

Parapets / Copings

Sloped parapets on the gabled end should be the same slope as the roof.

Factory-finished metal or properly-flashed precast concrete copings may be used on brick parapet walls.

All precast copings should have raked joints filled with elastomeric joint sealants.

Use factory-finished metal copings on stucco and metal wall panel parapet walls, matching the wall color. Be-hind a parapet wall, coping, flashing, and counter-flashing should match the roof color.

9design standards - basewide

Fascias, Gutters, and Downspouts

Incorporate continuous metal fascias that are no more than 8 inches in height for all sloped roofs.

Avoid the use of turn-down standing seam metal fascias.

Fascia finish shall match the roof color when occurring with metal roofing.

Gutters on sloped roofs are encour-aged and shall be factory finished to match the roof color.

When roofs are not visible, fascias shall match the color of the adjacent surface.

Connect downspouts to the storm drainage system wherever possible.

Integrate downspouts with archi-tectural details and match their color with that of the wall. Dark bronze may be used with ACRB approval.

Interior roof drains and open scup-pers are allowed only with approval of the ACRB.

Roof Vents and Elements

Minimize, consolidate, and organize roof penetrations on the least visible side of the building.

PVC pipes and other roof elements must be finished to match the roof color.

Do not use rooftop mechanical units.

When required, minimize the nega-tive visual effects with screening to match the roof color.

Consider the use of dormer vents to conceal and screen exhaust fans.

Avoid roof-mounted antennas.

10 architectural compatibility plan - Dover Air Force Base

ENTRANCES

Entrances not only act as the transitional element from exterior to interior, they also provide opportunities to create a focal point on a façade. They establish a user’s first impression and delineate the importance of the building by the size and architectural detailing of the entrance structure.

General

Ensure the building entrance is clearly visible and highlighted as a prominent feature.

Projected entrance features with gabled roof forms are preferred.

Create enclosed vestibules and weather-protected transition spaces at entrances.

Primary Entrances

Provide overhead enclosure for weather protection.

Use accent pavers in approach walk-way or at entry plaza feature.

Integrate handicapped ramps into overall design.

Locate newspaper, vending ma-chines, and similar elements out of view to avoid visual clutter.

Secondary Entrances

Reflect the character of the primary entry but to a lesser extent.

Recessed entries are acceptable to provide areas of shade and weather protection.

Service and Emergency Egress

Minimize visual impact with proper siting and access.

Provide unobtrusive service en-trances physically and visually sepa-rated from primary and secondary entrances.

Use landscaping and screen walls to screen and separate loading docks.

Do not use canopies at emergency egress doorways.

Drop-offs and Porte-cocheres

Limit porte-cocheres to special, high profile facilities.

Design as an integral part of the building entrance using the same style, form, and materials.

Treat these sites as special, high-pro-file design areas with corresponding amenities, design accents, and formal landscaping.

Handrails

Handrails shall be factory-finished with a surface matching dark bronze.

Integrate handrail designs with the facility design.

Plazas and Courtyards

The use of plazas and courtyards is encouraged at primary and second-ary entries.

Use concrete surfacing with special joint patterns and/or red colored concrete accent pavers with ACRB approval.

Incorporate landscaping and lighting into the design.

11design standards - basewide

WINDOWS AND DOORS

Windows and doors create a compliment in the facade and must be considered as individual details and for overall arrangement, order, and scale.

Openings

Use window type, size, placement and mullion pattern to emphasize the overall architectural design.

Use regularly spaced windows to establish contextual rhythms.

Set windows back at least 2 inches from the building facade.

Incorporate operable windows with screens where possible.

Transom windows / elements above doors / windows are encouraged.

Doors and Frames

Use dark bronze aluminum storefront systems with thermal-break construction.

Door, frame, and hardware colors shall match and be dark bronze.

All secondary-use and service doors and frames shall match adjacent surfaces.

Limit hollow metal frames to security doors, utility rooms, and outlying sites.

Sealants applied adjacent to windows and doors shall match the frame color.

Glazing

Use bronze tinted, dual-pane insulated e-glass.

Mirrored, spandrel, glass block and plastic glazing shall not be used.

Use off-white or dark bronze frames to match the architectural features.

Clerestories and Skylights

Develop clerestories or low-profile skylights integrally with the building design using either glass or translu-cent insulated panels.

Match clerestory windows with dark bronze colored frames.

Security Screens

Electronic security systems or secu-rity glazing are preferred to physical screens or bars.

Where physical barriers are required, develop simple rectangular designs that are unobtrusive.

12 architectural compatibility plan - Dover Air Force Base

ANCILLARY STRUCTURES

Similarity in ancillary structures, color, and materials provides continuity in the outdoor spaces on the base and reduces overall visual clutter.

General

Construct structures using the ap-proved Dover Tan brick, metal roofs, and precast concrete details.

Stucco may be used with ACRB approval.

Coordinate the siting of all ancillary structures with each other and adja-cent buildings.

Use non-weathering, corrosion resis-tant materials.

Landscape ancillary structures con-sistent with larger structures.

Integrate the structure with land-scaping, and other site elements.

Do not use temporary buildings or outdoor storage facilities.

Minimize the use and number of storage buildings, and consolidate in low-visibility areas.

Pavilions

Centrally locate pavilions between several facilities to create multipurpose use.

Use manufactured pavilions only in low-visibility locations.

Wood gazebos are not allowed.

Bike storage pavilions should match the materials of the adjacent facility.

Do not use enclosed bike storage lockers.

Use scored pavement patterns, or brick pavers with ACRB approval, as an accent.

Trellises and Arbors

Incorporate trellises into the design of high-visibility facilities to create areas of shade and interest.

Construct of low maintenance materials.

Integrate with building design / style and entry plazas or outdoor spaces.

Use commercial / non-residential style and detailing.

Incorporate vines or other landscape materials in the design.

13design standards - basewide

SCREENS AND ENCLOSURES

Screens and enclosures help to minimize the visual impact of undesirable features and provide separation and security where necessary. Both architectural and landscape screens – separately and in combination – can be applied to achieve visual continuity throughout the base.

General

Where possible, use landscaping instead of walls for screening.

Use landscaping to soften walls, fences, and screen dumpsters.

Locate utility components in the least visible area with adequate access to minimize the need for screening.

Ensure screens are high enough to conceal equipment, vending ma-chines, and utilities.

Walls

Construct freestanding walls with brick piers / columns and of split-faced block infill with a precast cap.

Articulate long walls with recessed sections for planting.

Generally, do not attach screen walls to buildings.

Do not place screen walls immediately adjacent to roadways or sidewalks.

Walls adjacent to brick buildings shall use brick with precast concrete cap.

Fences

Use decorative metal fencing with brick columns and low split-face block walls for high-visibility areas that don't require visual separation.

Vinyl-clad chain link fencing shall be black in industrial areas and dark green for perimeter fencing.

Wood is allowed only in the Family Housing setting.

Dumpster Enclosures

Locate dumpsters to minimize visual impact.

For new facilities, combine dumpster enclosures along service drives.

Use split face block walls with brick piers at the corners. Cap walls and piers with precast coping.

In high-visibility locations provide dark bronze gates to screen dumpsters.

Provide dark bronze protective bollards.

Provide concrete pads and access aprons.

Include landscaping areas and provi-sions for pedestrian access.

Force Protection

Observe force protection require-ments, integrating physical measures with the architecture.

Use a combination of walls, bollards, and tensile cables with landscape beds.

Develop all security walls to comply with the walls standards above.

Minimize the visibility of all force pro-tection devices with landscaping and integral designs.

Jersey Barriers are allowed only with ACRB approval. Do not paint.

Promote the use of polymer concrete portable planters as a barrier system.

14 architectural compatibility plan - Dover Air Force Base

LANDSCAPING

Use landscaping to enhance facilities and to unify the base. Establish a central organizing landscape theme that unifies and connects individual facilities.

Maintenance

Establish a maintenance program.

Use only approved planting materials as specified on the Landscape Materi-als listing Appendix A3.

Allow shrubs to mass naturally and avoid ornamental pruning.

Use 3/4-inch red barnyard stone in planting beds around facilities and shredded hardwood red mulch around individual plantings.

Provide sprinkler systems in planting beds and high-visibility areas.

Edging

Separate and define all planting areas from sod areas with metal edging.

Spade-cut edges are acceptable in low-visibility areas.

Raised planting beds constructed of brick or split face block may be used in focal-point areas.

Wood, timber, and plastic edging is not allowed.

Landscape Screens

Where possible, use landscaping instead of walls for screening.

Reduce the negative visual impacts of parking areas and unsightly features with landscape screening.

Use a three-tier landscaped screen that combines ground covers, shrubs, and small trees.

Vary plant species, and avoid regular-ly-spaced similar trees; use clusters.

Roadways

Primary roadways use same species, deciduous and coniferous street trees equally spaced to coordinate with light standards.

Secondary and access roadways use a more random spacing of mixed spe-cies in clusters and / or groupings at focal points.

Plant street trees on the building side of sidewalks.

15design standards - basewide

Parking Areas

Use shrubs in groupings and land-scaped berms to soften the visual impact of parking areas.

Reduce visual impact of large parking areas with landscape buffers and parking islands.

Use deciduous street trees in medi-ans and islands to create shade and interest.

Fill in between trees with low shrubs, flowers, and ground covers. Allow areas for pedestrian cross circulation.

Avoid the use of hedges outlining parking areas.

Facility

Use landscaping elements that compliment building architectural features and proportions.

Provide a soft transition from the horizontal ground plane to the plane of the building.

Highlight building entries and architectural features and screen unattractive building features such as utility risers or service areas.

Design randomly spaced plantings and tree massing to fill-out areas between facilities.

Use ground covers within planting beds.

Open Spaces

Use turf for all recreation areas, pa-rade grounds, lawns, and open fields.

Create undeveloped natural areas using native grasses and shrubs.

Incorporate maintenance-free ground cover materials in areas of steep slope or areas that are difficult to maintain.

16 architectural compatibility plan - Dover Air Force Base

WALKWAYS AND PATHS

Develop a consistent pedestrian circula-tion system of walkways and paths to enhance the community environment.

Connect passenger waiting shelters, out-door plazas, parks, and other pedestrian gathering sites into the overall circulation network.

Sidewalks

Provide walkways a minimum of 5 feet wide along all primary, secondary, and access roadways.

Maintain a minimum 3-foot wide land-scaped parkway between curb and sidewalk.

Provide curvilinear, meandering walks for dormitory and housing areas.

Highlight special-use locations, such as plazas, building entrances, and important intersections, with Dover Red brick paving with ACRB approval.

Size sidewalks appropriately for the visual scale of the facility and the amount of pedestrian traffic volume.

Use natural colored concrete with a broom finish and troweled edges for all walkways in developed areas.

In areas of secondary importance, building entrances should make use of joint patterns.

Crosswalks and Ramps

Ensure that all paths lead to the safest crossing point possible, and cross roadways at 90-degree angles.

Incorporate ADA access curb ramps and crosswalk markings into all crosswalks.

Use reflective paint or white striping to delineate crosswalks at special areas.

Mark crosswalks with 24"-wide longitudinal lines spaced four feet on center with no transverse lines.

Construct all concrete curb ramps with a waffle stamp pattern and flared curb ramps.

Provide for adequate drainage away from the ramp or by drainage grates.

Plazas and Courtyard Paving

Use Dover Red brick or concrete pav-ers as a unifying theme.

Concrete or brick pavers may be used as banding or at edges to create high-lights.

Use a basket weave or running bond paving pattern.

Recreation Trails

Provide a minimum 6-foot paved width in a free form configuration that follows the contours or other natural features.

Separate the trail system from vehicu-lar traffic by a minimum of 10 feet.

Take advantage of natural envi-ronments such as the golf course, wetland areas, etc.

Incorporate activity generators, interpretive signs and recreation opportunities.

Provide a 5-foot by 10-foot paved rest area approximately every mile.

Include a bench and litter receptacle at each location.

Use asphaltic concrete for trail sys-tems. In highly natural settings such as wetlands and wooded areas use compacted, crushed fines.

17design standards - basewide

ROADS

Develop the transportation network to provide a consistent experience through-out the base. An organized system of primary, secondary, and tertiary arteries must reinforce a logical hierarchy of design features.

Primary

Primary roadways are the widest and fastest arterials and will often contain two lanes of traffic in each direction often with planted medians.

Minimize stops and turns, and elimi-nate on-street parking.

Parking and service access curb cuts are discouraged.

Keep parking areas and buildings away from the road edge.

Secondary

Secondary roadways are feeder streets from access roads to primary roads.

On-street parking is discouraged.

Keep off-street parking areas away from the road edge.

Minimize the number of curb cuts from driveways and area entrances.

Tertiary

Tertiary roadways are the narrow-est and slowest public streets and provide access to individual sites or parking areas.

On-street parking and curb-cuts for driveways, parking lot entrances, and services drive entrances are allowed.

Maintain capability for large vehicles such as fire trucks and moving vans.

Service Drives

Service drives provide access for service vehicles to certain parts of a building or site.

Combine service drives for several facilities where possible.

Maintain setback between the build-ing and service drive.

Minimize the visual impact of service drives through correct placement of drives and landscape screening.

Paving

Use asphalt paving for all primary, secondary, and access roadways.

Use concrete paving in loading areas, dumpster enclosures and sites used by heavy vehicles.

Gravel surfacing may be used on patrol roads and outlying sites only.

Incorporate a concrete apron where gravel roads meet paved roads.

All patching shall match adjacent materials.

Brick and concrete pavers shall match Dover Red.

Use only white striping except when painting yellow no-passing striping.

Curb and Gutter

Comply with base CE standards for all 6-inch integrated concrete curb and gutter for all roadways and drives in developed areas.

Patrol roads and service drives in outlying areas may not require curb and gutter, with ACRB approval.

Wheel stops in lieu of curbs are not allowed.

Do not paint concrete curbs.

18 architectural compatibility plan - Dover Air Force Base

PARKING

Develop functional lots with clear circu-lation and a positive appearance that complements the facility. Provide a pleasant transition from the parking area to the facility.

General

Reduce large parking areas with land-scaped islands and planting strips.

Parking layout must address main-tenance, snow removal, safety, and accessibility issues.

Combine parking areas for adjacent facilities.

Avoid parking directly in front of primary building entrances.

Provide spacing between parking lots and buildings in compliance with force protection standards.

Avoid parking on roads or within 40 feet of an intersection.

Use the 90-degree parking configu-ration when possible.

Provide 4” wide white striping for all pavement markings.

Do not paint handicapped parking symbols to the asphalt.

Medians and Islands

Provide planting medians for every four rows of vehicles and planting islands for every 20 stalls.

Coordinate layout for light poles with the islands and minimize their number to provide the required illumination.

Provide designated areas for pedes-trian cross traffic.

Reserved Parking

Minimize the number of reserved spaces.

Designate spaces by rank or title with curb-mounted signs.

Paving

Asphalt paving is the standard.

Use concrete where required for heavy vehicles, motorcycle parking, and where fuel spills may occur.

Curb and Gutter

Use concrete curbs and gutters for parking areas.

Asphalt curbs, wood timbers, and precast wheel stops are prohibited.

Do not paint concrete curbs.

19design standards - basewide

SIGNS

Signs are an important and positive element in the overall base appearance.

Their purpose is to clearly communicate necessary or helpful information for directions, identification, and customer service without adding visual clutter.

General

Use concise, clear signing in ac-cordance with Air Force, AMC, and Dover AFB Sign Standards.

Minimize the number of signs used for each facility.

Signs must be consistent in style, placement, color, and language.

Avoid mottoes, insignias, super graphics, or individual titles on build-ings or identification signs.

Color

Use Park Service Brown for back-grounds with reflective white lettering on metal placards unless as noted in regulation signs.

Use dark bronze square metal posts.

Finish back of sign and fastening devices dark bronze.

Identification Signs

Limit the use of monument signs to entry gates, headquarters buildings, housing neighborhoods, and special use areas / facilities with ACRB approval.

Construct monument signs with brick columns with split-faced block infill and precast concrete caps. Use pin-mounted Helvetica letters.

Incorporate landscaping, accent lighting, and/or paving.

Facility identification signs with street addresses normally identify individual facilities and are generally free stand-ing and not applied to facility facades.

Display facility numbers in one loca-tion - at the back or side corner of buildings, coordinated with archi-tectural features.

Building-mounted signs or individual letters with corporate logos are al-lowed for commercial facility signs only with ACRB approval.

Direction Signs

Use to identify highly frequented or special interest destinations and street names.

Display the Air Mobility Command logo decal on the left of all street name signs.

Regulation Signs

Use for traffic control, parking, and base warnings.

Traffic control signs must follow the Manual on Uniform Traffic Control Devices administered by the Federal Highway Administration for color and display requirements.

Handicapped parking signs must fol-low AMC Exterior Sign Standards for color and display requirements.

Base warning signs must adhere to the Air Force Sign Standard for color and display requirements.

20 architectural compatibility plan - Dover Air Force Base

SITE FURNISHINGS

The common use and style of site ameni-ties will further unify the base, providing a “thread of continuity” throughout.

Reflect the basewide standard regardless of where site furnishings are placed.

General

Select site furnishings from the list on page A1.

Use dark bronze metal benches and furnishings with a factory applied powder-coat finish.

Seating / Benches

Provide seating along walkways, near building entries, and in courtyards and plazas.

Place benches within a paved area.

Litter / Ash Receptacles

Place at building entrances, path-ways, outdoor seating, and picnic areas.

Locate these to be functional, yet visually unobtrusive.

Planters

Minimize the use of freestanding planters.

When used, locate planters in con-junction with other exterior elements.

Use planters that match ash and litter receptacles in design.

Bike Racks

Provide bicycle-parking areas for all facilities. Combine areas for densely sited building.

Place bike racks on concrete pads in accessible locations near established bike routes and near secondary entrances to buildings.

Increase the numbers of available bike racks in residential and recre-ational areas.

Screen bicycle parking areas with landscaping or screen walls.

Barbecue Grills

Limit built-in grills to recreational areas, dormitories, and fire stations.

Use materials that compliment adjacent facilities.

Placement and design of built-in grills must be approved by the ACRB.

21design standards - basewide

Picnic Tables

Use factory finished, recycled plastic picnic tables with metal frames.

Do not use at administration yard areas or industrial facilities.

Provide mid-morning to late-after-noon shade for all picnic tables.

Limit tables to outdoor picnic or dining areas; and group to allow for large parties or individual family outings.

Bollards

Use bollards to protect buildings, equipment, and people from vehicle impact and to restrict access.

Use an 8-inch diameter, factory fin-ished dark bronze aluminum, domed-top bollard as the standard.

Use same style bollard with single-function luminaire at pedestrian areas, pathways, and entrances.

For force protection use an 8-inch diameter, concrete filled, steel pipe.

Cap lighted force protection bollards with a pre-manufactured, domed-top, single luminaire.

For bollards protecting equipment or buildings from vehicle damage, paint to match adjacent surfaces.

For special applications concrete monumental bollards may be used with ACRB approval.

Tree Grates

Use black tree grates at all formal pla-zas and courtyards set into concrete paving. Accent with brick pavers.

Playground Equipment

Provide consistent-style pre-manu-factured play equipment at parks, family housing areas, child develop-ment centers, community centers, and recreational areas.

Place equipment with safe ground surfacing, benches, litter receptacles, and landscaping for shade.

Provide adequate pedestrian circu-lation paths to play areas.

Flag Poles

Use a brushed aluminum pole, mounted on a concrete base.

Create a sense of place at flag pole locations with landscape or plaza design.

22 architectural compatibility plan - Dover Air Force Base

LIGHTING

Exterior lighting is a system that directly impacts the visual qualities of the base.

By day, the fixtures and poles add visual character and rhythm to the streetscape.

By night these amenities contribute to the perception of safety and comfort.

Use common components throughout the base.

General

Use underground utility service to lighting fixtures.

Use high-pressure sodium lamps for all applications.

Photometrics are required for all applications.

Streets

All classifications of roadways will use the same luminaries, poles, and mounting height.

Use factory finished luminaries and poles for all roadways.

Equally space poles on alternating sides of all roadways.

Parking Areas

Use arm-mounted, square, shoebox-type luminaries in factory finished dark bronze.

Use multiple luminaries on dark bronze, square poles to reduce the number of poles.

Coordinate pole placement with park-ing island locations.

Walkways and Paths

Provide pedestrian-scaled lighting fixtures throughout housing area and along recreation trails and sidewalks not adjacent to roadways.

Use dark bronze arm-mounted shoe-box fixtures.

Equally space light fixtures for side-walks on same side of walk.

Mounting Heights

Control spillover light near residential areas.

Keep mounting heights low and consistent. Any lights mounted over 30 feet high require ACRB approval.

Architectural and Accent

Incorporate recessed, wall-mounted luminaries to wash light across plaza, paving, and stairs.

Minimize and integrate into the building design the use of building mounted fixtures for general illu-mination of service yards and outdoor spaces.

Uplight architectural, landscaping, and building entrance features to emphasize importance and hierarchy.

23design standards - basewide

UTILITIES

Use consistent utility components and place electrical services and building feeds underground to reduce overhead visual clutter.

Utility Lines and Structures

Place all utility lines underground.

Do not cut pavements to install utilities - bore whenever possible.

Avoid free-standing utility structures where possible.

Use underground vaults for equip-ment where possible.

Locate equipment on concrete pads.

Fire Hydrants

Locate fire hydrants at least 5 feet away from other structures. Maintain a 30-inch clear area.

Paint hydrants dark bronze.

Utility Components

Carefully place and organize equip-ment and services.

Locate mechanical equipment on the least visible side of the building.

Screen equipment with landscaping materials or screen walls.

If equipment is placed within 10 feet of a building, paint dark bronze unless within 10' of a light-colored surface, then match the wall color.

Minimize the use of all externally at-tached meters and control devices. If used, paint to match the wall color.

Exterior surface-mounted utility conduits, lines, or equipment are not allowed (except meters and control devices).

In remote locations, paint freestand-ing pipes and above-ground utility system components dark bronze.

Communications

Collocate coaxial and telephone exte-rior components and entry points.

Align all communication components with one another on the horizontal and vertical plane.

The flightline encompasses aircraft hangars and maintenance facili-ties. Buildings should be designed with forms, materials, and color palettes similar to those of the Basewide area, but with simplified detailing more appropriate for their function. Large buildings – common to this area

– require careful design and orientation to avoid unappealing monolithic facades.

flightline / industrial architectural compatibility plan - Dover Air Force Base

BUILDINGS

Observe all horizontal and vertical safety restrictions along the flightline.

Consolidate functions where possible to eliminate smaller, individual buildings.

Integrate large masses and volumes with smaller ones to minimize the scale.

Only use pavement to buildings when necessary.

Lower the apparent height of hangars and warehouses by modulating build-ing elevations with submasses, clere-stories, openings, material changes, and architectural detailing.

Avoid large, flat facades.

All industrial facilities require curbs and bollard protection.

WALL SYSTEMS

On smaller administration facilities, use tan brick or a combination of tan brick and taupe brown stucco.

On larger facilities, use a combina-tion of tan brick and flat profile, sandstone colored metal panels.

Use a horizontal expression of sand-stone colored metal panels.

Do not use metal panel as the sole material for any structure.

Cap brick parapet walls with metal or precast concrete coping.

Locate visible vents and louvers as planned design elements; avoid ran-dom placement.

Vents and louvers are to match the color of adjacent surfaces.

25design standards - flightline

ROOF SYSTEMS

All structures shall use gabled or single sloped parapet end walls.

Low-slope metal roofs are allowed only for very large volumes or accent sub-masses with ACRB approval.

Metal roofing for large industrial buildings may be of the minimum slope recommended by the roofing manufacturer.

Lower appendages on large facilities, small buildings, and entries may use open gabled or hipped roofs with ACRB approval.

WINDOWS AND DOORS

Use windows, clerestories, and trans-lucent fiberglass panels to promote natural lighting and reduce the mass of the facade.

Accent primary entrance doors to express their use and importance.

Secondary-use doors and frames, such as service, shall match adjacent wall surfaces.

Large hangar and overhead doors must match the wall color.

LANDSCAPING

Use landscaping to soften and re-duce the scale of larger facilities.

Minimize the use of deciduous trees and shrubs to prevent leaf buildup along the apron and runway.

Reduce the density of landscaping by grouping landscape elements at entries and high-visibility areas.

SCREENS AND ENCLOSURES

Integrate physical security measures into the architectural design process.

Coordinate security walls with the design of adjacent facilities or the immediate context.

Use screen walls, bollards, and de-fined roadways in selected locations to direct and limit facility access.

Painting of Jersey barriers is prohibited.

Residential architectural settings should express a neighborhood im-age that distinguishes them from the remainder of the base. Achiev-ing architectural compatibility relies on the use of consistent building materials, site furnishings, and landscaping. Residents are afforded some opportuni-ties to use the standards creatively to express individual pride of place in and around their homes.

family housing architectural compatibility plan - Dover Air Force Base

GENERAL

Organize units into cohesive neigh-borhoods with curvilinear streets and minimize the use of cul-de-sacs.

The existing housing styles should be reviewed when planning for new units.

Construct new community facilities following the basewide design standards.

For all brick applications use Dover Red in lieu of Dover Tan.

Use vinyl siding, asphalt or composi-tion shingles with Dover Red brick accents.

WALL SYSTEMS

Use trim and siding colors from the three approved color schemes indi-cated on page A1.

Alternate randomly exterior color schemes.

Accent and shutter colors shall match the approved scheme.

ROOF SYSTEMS

Use gabled or hipped roofs with between 4:12 and 6:12 pitch.

Consider the use of dormers.

Use shingles with an architectural profile.

Use fascias, gutters, downspouts, and soffits finished to match the trim.

Use factory-finished, corrosion resis-tant materials.

ANCILLARY STRUCTURES

Install passenger waiting shelters at locations convenient to the family housing areas.

Use shelters that are sized to accom-modate the number of people using them.

27design standards - family housing

LANDSCAPING

Use mixed species and informal landscaping to integrate new with existing housing areas and to improve the overall community setting.

Add plantings for shade and privacy and develop foundation plantings.

Landscape the perimeter edges of recreational and common areas.

Use landscaped berms to soften major arterial roads and screen undesirable views.

Develop a street tree program.

All self-help landscape materials are to follow the ACRB's approved material list.

Follow basewide standards for landscape edging.

SCREENS AND ENCLOSURES

Use wood shadowbox fencing for backyard privacy.

Use the base standard dark green vinyl-coated chain link fencing around the base boundary of the housing area.

ROADS

Enhance streetscapes with landscaping, walkways, and site furnishings.

Use road features such as smaller radius corners and narrow street widths to reduce traffic speeds.

WALKWAYS AND PATHS

Emphasize pedestrian and bicycle circulation within housing areas and connect housing to community facilities.

Provide seating and other basewide site furnishings along walkways.

Use concrete slabs for patios.

NEIGHBORHOOD ENTRIES

Construct neighborhood entrance signs reflecting the architectural character of the setting.

Provide accent landscaping, lighting, and brick paving.

LIGHTING AND UTILITIES

Provide pedestrian-scale lighting fixtures throughout housing areas.

Provide parking lot and street lighting that matches the basewide standard for primary roads and parking lots.

28 architectural compatibility plan - Dover Air Force Base

The ACP is a multipurpose tool that shall be used throughout the entire planning, programming, and design process, from inception to project completion for any project on base.

The ACP is implemented by the Base Civil Engineer.

While architectural designers are the primary users of the plan, it must also be used by project managers, programmers, planners, engineers, maintenance and operations personnel, self-help personnel, SABER per-sonnel and the Architectural Compatibility Review Board

(ACRB).

Any items purchased for the exterior of buildings

– including those purchased with impact cards – must conform to the requirements pre scribed in the ACP.

In the next three pages, key elements in the im ple men t-a tion process are highlighted.

implementation

29implementation

Key Elements

Adhering to key elements of the imple-mentation process leads to success in designing excellent facilities that will be compatible with and a part of the whole community.

Distribute the ACP.

Establish the Architectural Compati-bility Review Board (ACRB).

Hire good designers.

Respect the General Plan.

Process proper submittals.

Cross-reference all planning and design documents to the ACP.

Distribute the ACP

Distribution of the plan should be as wide as possible. On base, provide cop-ies to commanders of all major units and tenants, the civil engineering squadron commander, operations, branch chiefs, base architect, and community planner.

Provide copies to the major command and headquarters representatives.

Establish the ACRB

The ACRB is the installation approval au-thority for all designs and visual features on the installation.

The ACRB is organized by the Base Civil Engineer (BCE).

The chairperson as appointed.

Members include the base architect, community planner, chief engineer, and others as determined by the chairperson.

The base architect, engineering disciplines, and project manager review designs regardless of ACRB involvement.

The ACRB meets as required or as a subgroup of the installation Facilities Board (FB).

Most projects, regardless of size, must be approved by the ACRB. (The chairperson makes the determination on review requirements).

Design projects are submitted to the ACRB by the base-assigned project manager (see project checklist on page A5 for submittal requirements).

ACRB Project Checklist

All projects and service contracts shall be reviewed by the ACRB using the checklist on page A5. The Base project manager is responsible for providing the design checklist to the ACRB for completion.

30 architectural compatibility plan - Dover Air Force Base

Hire Good Designers

Ensure the involvement of design oriented personnel in the A-E selection process.

Select A-E firms that are sensitive to and understand architectural compatibility.

The AF project manager provides cop-ies of the ACP to the designer before design begins.

Respect the General Plan

All new projects must agree with the goals and objectives outlined in the in-stallation master plan to ensure that the siting of new projects is compatible with adjacent facilities.

Process Proper Submittals

All design projects are reviewed by the ACRB. This includes Requirements Documents, Concept Design, and Final Design submittals.

Submittals shall include the required information and data at the appropri-ate times, and the process shall allow adequate review time.

Requirements Document

In the initial submittal, the A-E defines

– with the help of the AF – the require-ments for the project. It may explore potential solutions, but more importantly, it includes bubble diagrams depicting the relationships of major functional elements and site / facility development options. This submittal is reviewed by the ACRB.

Each submitted package will comprise the following.

Scope / Programming Requirements

Project Description

Goals and Objectives

Sub-area Development Plans

Site Inventory / Site Analysis

Spatial Relationship Analysis (i.e., relationship to site)

Adjacent Facilities and Project Site Photos

Site Inventory / Site Analysis includes (but is not limited to): vehicular traffic patterns, view, climatic conditions, envi-ronmental, safety, utility constraints, and geographic conditions. Refer to sketch.

31implementation

Develop site plans, floor plans, roof plans, and building elevations concur-rently to ensure the proposed solution is a comprehensive design. Floor plans must be developed with consideration of the site and building massing.

The ACRB will review concept submit-tals. If the initial submittal is rejected, or if there are significant concerns or com-ments, a resubmission is required prior to proceeding to the next design stage.

Each submittal package shall include:

Concise Verbalized Design Concept

Systems Description

Adjacent Facilities and Site Photos

Site Plans (colored)

Floor Plans

Composite Elevations (with color and shadows)

Mechanical / Electrical Communica-tions Entrances and Equipment Locations and Configurations.

Building Sections

Roof Plan

Massing or Perspective Sketches

Study Model (as required)

Cost Estimate

Final Design

The final design shall remain consistent with the approved concept design. It includes highly developed drawings that further refine and detail the visual and functional quality of the design.

As a minimum, each submittal package shall include the following:

Formal Colored Rendering (early in this phase)

Material / Color Boards (interior and exterior)

Catalog Cuts (photos)

Design Analysis

Cost Estimate

Contract Documents

Contract Documents (CDs)

Contract documents must be in Auto- CAD and include comprehensive draw-ings and specifications to meet all of the standards defined by the ACP.

All civil, mechanical, and electrical drawings must be consistent with the ar-chitectural drawings. All utility elements such as light fixtures, transformers, panels, grilles, vents, piping, etc., must be shown on the architectural drawings.

Concept Design

This submittal must include adequate information to fully describe the project design, allowing customers / clients to easily comprehend the proposed solu-tion. The goal is to achieve AF customer understanding and approval early in this process.

Multiple submittals may be required for large or complex projects. Generally, completion of concept design requires two submittals.

This is the start of the file's text. The full file is on GovTribe.