Attachment_26_-_08_71_00_Door_Hardware.pdf

PDF 127 KB Posted

Attached to
LRAFB Multiple Award Construction Contract (MACC) Federal contract opportunity
Solicitation number
FA4460-16-R-0002
Issued by
Department of the Air Force Air Mobility Command

About this file

LRAFB 08 71 00 Door Hardware

View the file

Other files for this federal contract opportunity

Other files attached to LRAFB Multiple Award Construction Contract (MACC), newest first.
File Type Posted
FA4460-16-R-0002-0006.pdf PDF
Attachment_25_-_NKAK_15-1088_Rpr_Sus_Aircraft_MX_Shop_Restroom_Bldg_364_Revised_24_June_2016.pdf PDF
Attachment_27_-_ADA_Clarification.pdf PDF
FA4460-16-R-0002-0005.pdf PDF
Attachment_23_-_LRAFB_MACC_Site_Visit_Questions_ _Answers.pdf PDF
Attachment_24_-_B-364_Floorplans.pdf PDF
Attachment_21_-_Solicitation_Questions_ _Answers_2.pdf PDF
Attachment_22_-_Site_Visit_Attendance_Rosters.pdf PDF
FA4460-16-R-0002-0004.pdf PDF
FA4460-16-R-0002-0003.pdf PDF
Attachment_20_-_Solicitation_Questions_ _Answers.pdf PDF
NKAK_15-1088_Rpr_Acft_Mx_Shop_Restroom_B-364.pdf PDF
FA4460-16-R-0002-0002.pdf PDF
Attachment_19_-_Site_Visit_Attendee_Information.xlsx XLSX spreadsheet
Attachment_18_-_LRAFB_Architectural_Compatibility_Guide.pdf PDF
FA4460-16-R-0002-U0001.pdf PDF
Attachment_7_-_LRAFB_Architectural_Design_Guide_Supplement.pdf PDF
Attachment_1_-_EMIS_Instruction_Guide.doc DOC document
Attachment_8_-_LRAFB_Civil_Design_Criteria.pdf PDF
Attachment_16_-_LRAFB_Information.pdf PDF
Attachment_15_-_LRAFB_Section_26_05_04_Raceways.pdf PDF
Attachment_14_-_LRAFB_Section_09_06_89_Typical_Finish_Schedule.pdf PDF
Attachment_13_-_LRAFB_Mechanical_Design_Criteria.pdf PDF
Attachment_3_-_C D_Report.doc DOC document
Attachment_5_-_Financial_Institution_Reference_Sheet.docx DOCX document
Attachment_6_-_Seed_Project_Package.zip ZIP file
Attachment_4_-_Past_Performance_Package.docx DOCX document
Attachment_12_-_LRAFB_Fire_Detection_and_Alarm_Systems.pdf PDF
FA4460-16-R-0002.pdf PDF
Attachment_17_-_Scheduled_Government_Furnished_Property.pdf PDF
MACC_Statement_of_Work.pdf PDF
Attachment_2_-_Environmental_MOA.doc DOC document
Attachment_10_-_LRAFB_Computer_Telephone_Systems.pdf PDF
Attachment_11_-_LRAFB_Building_Mass_Notification_System.pdf PDF
Attachment_7_-_LRAFB_Architectural_Design_Guide_Supplement.pdf PDF
Attachment_9_-_LRAFB_Electrical_Design_Standards.pdf PDF
Show all 36

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DOOR HARDWARE 08 71 00 - 11

SECTION 08 71 00 – DOOR HARDWARE

PART 1 - GENERAL

1.01 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by basic designation only.

AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM)

ASTM E 283 (1991) Determining the Rate of Air Leakage Through Exterior

Windows, Curtain Walls and Doors Under Specified Pressure

Differences Across the Specimen

BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA)

BHMA L & R Directory (Effective thru Jun 1999) Directory of Certified Locks &

Latches

BHMA Closer Directory (Effective thru Jul (1999) Directory of Certified Door Closers

BHMA Exit Devices Directory (Effective thru Aug 1998) Directory of Certified Exit Devices

BHMA A156.1 (1997) Butts and Hinges

BHMA A156.2 (1996) Bored and Preassembled Locks and Latches

BHMA A156.3 (1994) Exit Devices

BHMA A156.4 (1992) Door Controls - Closers

BHMA A156.5 (1992) Auxiliary Locks & Associated Products

BHMA A156.6 (1994) Architectural Door Trim

BHMA A156.7 (1997) Template Hinge Dimensions

BHMA A156.8 (1994) Door Controls - Overhead Stops and Holders

BHMA A156.15 (1995) Closer Holder Release Devices

BHMA A156.16 (1989) Auxiliary Hardware

BHMA A156.18 (1993) Materials and Finishes

BHMA A156.21 (1996) Thresholds

DOOR AND HARDWARE INSTITUTE (DHI)

DHI Locations for CSD (1997) Recommended Locations for Builders' Hardware for

Custom Steel Doors and Frames

DHI Locations for SSD (1990) Recommended Locations for Architectural Hardware for

Standard Steel Doors and Frames

DHI ANSI/DHI A115.1G (1994) Installation Guide for Doors and Hardware

DHI ANSI/DHI A115-W (Varies) Wood Door Hardware Standards

(Incl All5-W1 thru A115-W9)

NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)

NFPA 80 (1999) Fire Doors and Fire Windows

NFPA 101 (1997; Errata 97-1; TIA-97-1) Life Safety Code

NFPA 105 (1999) Installation of Smoke-Control Door Assemblies

1.02 SUBMITTALS

A. Government approval is required for all submittals. The following shall be submitted in accordance with Section 01 33 00 SUBMITTAL PROCEDURES

B. Hardware Schedule

C. Hardware schedule listing all items to be furnished. The schedule shall include for each item:

the quantities; manufacturer's name and catalog numbers; the ANSI number specified, sizes;

detail information and catalog cuts; finishes; door and frame size and materials; location and hardware set identification cross-references to drawings; corresponding reference standard type number or function number from manufacturer's catalog if not covered by ANSI or BHMA;

and list of abbreviations and template numbers.

1.03 DELIVERY, STORAGE, AND HANDLING

Hardware shall be delivered to the project site in the manufacturer's original packages. Each article of hardware shall be individually packaged in the manufacturer's standard commercial carton or container, and shall be properly marked or labeled to be readily identifiable with the approved hardware schedule. Each change key shall be tagged or otherwise identified with the door for which its cylinder is intended. Where double cylinder functions are used or where it is not obvious which is the key side of a door, appropriate instructions shall be included with the lock and on the hardware schedule. Manufacturer's printed installation instructions, fasteners, and special tools shall be included in each package.

1.04 SPECIAL TOOLS

Special tools, such as those supplied by the manufacturer, unique wrenches, and dogging keys, shall be provided as required to adjust hardware items.

1.05 WARRANTY

Manufacturer's standard performance guarantees or warranties that extend beyond a one year period shall be provided.

1.06 OPERATION AND MAINTENANCE MANUALS

Three complete copies of maintenance instructions listing routine maintenance procedures, possible breakdowns and repairs, and troubleshooting guides shall be provided.

PART 2 - PRODUCTS

2.01 GENERAL HARDWARE REQUIREMENTS

Hardware shall conform to the requirements specified herein and the DOOR HARDWARE SCHEDULES listed at the end of this section. All doors shall be operated by curved return lever handles, touch bar exit devices, J407 Pulls or J301/304 Push Plates. Door knobs are NOT acceptable devices.

2.02 TEMPLATES

Requirements for hardware to be mounted on metal doors or metal frames shall be coordinated between hardware manufacturer and door or frame manufacturer by use of templates and other information to establish location, reinforcement required, size of holes, and similar details.

Templates of hinges shall conform to BHMA A156.7.

2.03 HINGES

Hinges shall conform to BHMA A156.1. Hinges used on metal doors and frames shall also conform to BHMA A156.7. Hinges shall be at a minimum, Heavy Weight, 4-1/ 2” x 4-1/ 2” ANSI 5111, five knuckle with four ball bearings, non-rising removable pin with button tip and plug. Base shall be stainless steel or brass for exterior doors.

A. Hinges for Reverse Bevel Doors with Locks

Hinges for reverse bevel doors with locks shall have pins that are made nonremovable by means such as a set screw in the barrel, or safety stud, when the door is in the closed position.

2.04 LEVER HANDLE LOCKSETS & DEADBOLTS

To the maximum extent possible, lever handle locksets and deadbolts, and all components thereof, including cylinders and removable cores, shall be the products of a single manufacturer. Lock fronts for double-acting doors shall be rounded. Strikes for wood doors shall be furnished with wrought boxes.

A. Lever Handle Cylindrical Locksets

Lever Handle Cylindrical Locksets, and strikes shall be series 4000, and shall conform to BHMA A156.2, Grade 1. Lever Handle Cylindrical Locksets & Deadbolts shall have adjustable bevel fronts or otherwise conform to the shape of the door. Lever handles shall be Curved Return 14D, Best Series 9K, Grade 1, function ANSI F81 or approved equal.

B. Tubular Deadbolts

Tubular Deadbolts shall conform to BHMA A156.5, Grade 1.

C. Lock Cylinders/Interchangeable Key Cores

Lock Cylinders/Interhangeable Key Cores shall comply with BHMA A156.5. Lock cylinders/Interchangeable Key Cores shall be Best Lock Corp., 7 PIN interchangeable key core compatible. Final key cores shall be provided by this contract and be an extension of the existing Best style A3 keying system. Final coded core shall be delivered to LRAFB Locksmith Shop directly from the manufacturer or his designated supplier. Final coded cores will be installed by LRAFB Locksmith Shop. Provide two coded keys with each core. Disassembly of Lever Handle Cylindrical lockset or exit device shall not be required to remove core from lockset. All locksets, and lockable exit devices shall accept and be Best Lock Corp., 7 PIN interchangeable key core compatible.

D. Lock Trim

Lock trim shall be cast, forged, or heavy wrought construction of commercial plain design. In addition to meeting the test requirement of BHMA A156.2, lever handles, roses, and escutcheons shall be 0.050 inch thick, if unreinforced. If reinforced, the outer shell shall be

0.035 inch thick and the combined thickness shall be 0.070 inch except that knob shanks shall be 0.060 inch thick.

2.05 EXIT DEVICES AND EXIT DEVICE ACCESSORIES

Exit devices and exit device accessories shall conform to BHMA A156.3, Grade 1.

A. Exit Devices and Auxiliary Items

Trim shall be of wrought construction and commercial plain design with straight, beveled, or smoothly rounded sides, corners, and edges. Adjustable flush mortise strikes shall be provided vertical rod devices. Open back strikes shall be provided for pairs of doors with mortise and vertical rod devices; except open back strikes shall be used on labeled doors only where specifically provided for in the published listings. Touch bars shall be provided instead of conventional crossbars and arms. Von Duprin Series 99, Precision Hardware Inc/Apex 2000 Series or Hager Company Inc 4500 Series.

2.06 DOOR CLOSING DEVICES

Door closing devices shall conform to BHMA A156.4, Grade 1. Closing devices shall be products of one manufacturer for each type specified. The opening resistance of closing devices shall not exceed 5 lbs applied at the latch stile.

A. Surface Type Closers

Surface type closers shall be Grade 1, Series C02000 Full Cover with options PT-4H, Size 1, and PT-4D with back check position valve. Except as otherwise specified, sizes shall conform to the manufacturer's published recommendations. All closers be top jamb (push side) mounted.

2.07 ARCHITECTURAL DOOR TRIM

Architectural door trim shall conform to BHMA A156.6.

A. Door Protection Plates

1. Kick Plates

Kick plates shall be Type J102 stainless steel. Width of plates shall be 2 inches less than door width for single doors 1 inch less for pairs of doors. Height shall be 10 inches. Edges of metal plates shall be beveled.

B. Push Plates

1. Push-Plates

Push-pull plates shall be Type J301/304, Grade 1, 0.050 inch thick minimum stainless steel beveled four edges.

C. Door Pulls and Plate

1. Door Pulls

Door Pull and Plate shall be Category J407 stainless steel, Grade 1.

2.08 MISCELLANEOUS

A. Metal Thresholds

Thresholds shall conform to BHMA A156.21. Thresholds for exterior doors shall be extruded aluminum of the type indicated and shall provide proper clearance and an effective seal with specified weather stripping. Where required, thresholds shall be modified to receive projecting bolts of exit devices. Thresholds shall be beveled with slopes not exceeding 1:2 and with heights not exceeding 1/2 inch. Air leakage rate of weatherstripping shall not exceed 0.5 cubic feet per minute per lineal foot of crack when tested in accordance with ASTM E 283 at standard test conditions.

B. Rain Drips

Extruded aluminum, not less than 0.07 inch thick, clear anodized aluminum. Door sill rain drips shall be 1-1/2 inches to 1-3/4 inches high by 5/8 inch projection. Overhead rain drips shall be approximately 1-1/2 inches high by 2-1/2 inches projection and shall extend 2 inches on either side of the door opening width.

C. Aluminum Housed Type Weatherseals

Weatherseals of the type indicated shall consist of extruded aluminum retainers not less than

0.07 inch wall thickness with TPE inserts. Aluminum shall be clear anodized. Weatherseal material shall be of an industrial/commercial grade. Seals shall remain functional through all weather and temperature conditions. Air leakage rate of weatherstripping shall not exceed 0.5 cubic feet per minute per lineal foot of crack when tested in accordance with ASTM E 283 at standard test conditions.

D. Door Stops

Wall stops, floor stops and combination stop and holders shall conform to BHMA A156.16.

2.09 FASTENINGS

Fastenings of proper type, size, quantity, and finish shall be supplied with each article of hardware. Machine screws and expansion shields shall be used for attaching hardware to concrete or masonry. Fastenings exposed to the weather in the finished work shall be of brass, bronze, or stainless steel. Sex bolts, through bolts, or machine screws and grommet nuts, where used on reverse-bevel exterior doors equipped with half-surface or full-surface hinges, shall employ one-way screws or other approved tamperproof screws. Screws for the jamb leaf of half-mortise and full-surface hinges attached to structural steel frames shall be one-way or other approved tamperproof type.

2.010 FINISHES

Unless otherwise specified, finishes shall conform to those identified in BHMA A156.18. All finishes shall be Satin Chromium Plated unless otherwise noted.

2.011 HARDWARE FOR FIRE DOORS

Hardware for fire doors shall conform to the requirements of NFPA 80and NFPA 101.

PART 3 - EXECUTION

3.01 APPLICATION

Hardware shall be located in accordance with DHI Locations for CSD and DHI Locations for SSD, except that deadlocks shall be mounted 48 inches above finish floor. When approved, slight variations in locations or dimensions will be permitted. Application shall be in accordance with DHI ANSI/DHI A115.1G or DHI ANSI/DHI A115-W. Door control devices for exterior doors such as closers and holders, shall be attached to doors with thru bolts and nuts or sex bolts.

Alternate fastening methods may be approved by the Contracting Officer’s Representative when manufacturers' documentation is submitted to verify that the fastening devices and door reinforcements are adequate to resist wind induced stresses.

A. Hardware for Fire Doors and Smoke-Control Door Assemblies

Hardware for fire doors shall be installed in accordance with the requirements of NFPA 80. Exit devices installed on fire doors shall have a visible label bearing the marking "Fire Exit Hardware". Other hardware installed on fire doors, such as locksets, closers, and hinges shall have a visible label or stamp indicating that the hardware items have been approved by an approved testing agency for installation on fire-rated doors. Hardware for smoke-control door assemblies shall be installed in accordance with NFPA 105.

B. Door-Closing Devices

Door-closing devices shall be installed and adjusted in accordance with the templates and printed instructions supplied by the manufacturer of the devices. All doors shall have the closer mounted on the push side of the door.

C. Kick Plates and Mop Plates

Kick plates shall be installed on the push side of single-acting doors and on both sides of double-acting doors. Mop plates shall be installed on the pull side of the single acting doors.

D. Thresholds

Thresholds shall be secured with a minimum of three fasteners per single door width and six fasteners per double door width with a maximum spacing of 12 inches. Exterior thresholds shall be installed in a bed of sealant with expansion anchors and stainless steel screws, except that bronze or anodized bronze thresholds shall be installed with expansion anchors with brass screws. Minimum screw size shall be No. 10 length, dependent on job conditions, with a minimum of 3/4 inch thread engagement into the floor or anchoring device used.

E. Rain Drips

Door sill rain drips shall align with the bottom edge of the door. Overhead rain drips shall align with bottom edge of door frame rabbet. Drips shall be set in sealant and fastened with stainless steel screws.

F. Weatherseals

Weatherseals shall be located as indicated, snug to door face and fastened in place with color matched metal screws after door and frames have been finish painted. Screw spacing shall be as recommended by manufacturer.

3.02 OPERATIONAL TESTS

Prior to acceptance of any electrical hardware system, an operational test shall be performed to determine if devices are operating as intended by the specifications. Wiring shall be tested for correct voltage, current carrying capacity, and proper grounding. Stray voltages in lock wiring shall be eliminated to prevent locking devices from releasing in critical situations.

3.03 FIELD QUALITY CONTROL

Contractor shall inspect the completed installation and certify that the hardware has been furnished and installed in accordance with the manufacturers' instructions and as specified. The inspection report shall identify any malfunctioning items and recommend adjustment or replacement as appropriate.

3.04 HARDWARE SETS

Contractor shall provide and install door hardware as indicated on the following door hardware schedules. All door hardware shall be Grade 1. All door hardware shall be Builder Hardware Manufactures Association (BHMA) Satin Chromium Plated, Brass, Bronze or Steel material unless otherwise noted to be Satin stainless steel (SS), brushed aluminum (A) or clear aluminum (X). Only items used within the conditioned building envelope will be allowed to be plated steel.

DOOR HARDWARE SCHEDULE, ALL INTERIOR DOORS

1 Stain Grade Solid Core Wood

Door, Light Oak Finish 1-3/ 4” x 3’-0” x 7’-0” in 16 gauge steel frame

1-1/ 2 Pair Full Mortise Hinges Ball Bearing Heavy Weight, Stainless Steel, 4-1/ 2” x 4-1/ 2” ANSI A5111, Grade 1

HAGER BB1199 BHMA 626 or approved equal

1 Kick Plate 10” x 34”, BHMA 626, Grade 1

HAGER 194S-10”x34”, BHMA 626 or approved equal

3 Silencers Rubber or Vinyl (not painted)

1 Door Closer Grade 1, Thru-bolted, LCN 4020N

Series Smoothee or approved equal

1 Dead Bolt, Tubular Best, 83T Series, Grade 1

83T 7 K S5 626 CS or approved equal

1 Lever Handle Cylindrical Curved Return Best Series 9K, Grade 1, ANSI F81

Lockset 93K 7 AB 14D S3 626 or approved equal

1 Tri Base Floor Stop HAGER 295 F, Cast Brass, BHMA 626 finish, w/ Black Rubber Bumper, Grade 1, or approved equal

2 Changeable Key Cores Steel Construction Key Cores, 7 Pin Best Lock

Compatible

1 Door Viewer HAGER 1758, 160 degree door viewer with privacy flap. US26D finish

DOOR HARDWARE SCHEDULE, ALL EXTERIOR STEEL DOORS

1 Prefinished Exterior Grade

Steel Door, 5” x 20” Lite 1-3/ 4” x 3’-0” x 7’-0” in 16 gauge steel frame

1-1/ 2 Pair Full Mortise Hinges Ball Bearing Heavy Weight, Stainless Steel, 4-1/ 2” x 4-1/ 2” ANSI A5111, Grade 1

HAGER BB1199 BHMA 626 or approved equal

1 Kick Plate 10” x 34”, BHMA 626, Grade 1

HAGER 194S-10”x34”, BHMA 626 or approved equal

3 Silencers Rubber or Vinyl

1 Door Closer Grade 1, Thru-bolted, LCN 4020N

Series Smoothee or approved equal

1 Lever Handle Cylindrical Curved Return Von Duprin, Series 992L w/ # 17 Lever

Lockset Design Option, Grade 1 or approved equal

1 Panic Bar Device Grade 1, Von Duprin Series 99, CD9948L, or approved equal

1 Vertical Rod Set Von Duprin Series 99 concealed vertical rod device, Grade 1 or approved equal

2 Vertical Rod Mortise

Strike Plates Flush mortise strike plates top & bottom

1 Tri Base Floor Stop HAGER 295 F, Cast Brass, BHMA 626 finish, w/ Black Rubber Bumper, Grade 1 or approved equal

1 Threshold HAGAR, 417S, Finish A, door width x 6” x 1/ 4” or approved equal, set in a bed of elastomeric sealant.

1 Door Bottom Sweep Hager, 770S/B w/ nylon brush, Finish A, door width, Grade 1

1 Weather-stripping

Gasket Set Jambs and Head, Hager 863S, Finish X w/ TPE Gasket

2 Changeable Key Cores Steel Construction Key Cores, 7 Pin Best Lock

Compatible

DOOR HARDWARE SCHEDULE, ALL EXTERIOR DOUBLE STEEL DOORS

2 Prefinished Exterior Grade

Steel Door, 5” x 20” Lite 1-3/ 4” x 3’-0” x 7’-0” in 16 gauge steel frame

3 Pair Full Mortise Hinges Ball Bearing Heavy Weight, Stainless Steel, 4-1/ 2” x 4-1/ 2” ANSI A5111, Grade 1

HAGER BB1199 BHMA 626 or approved equal

2 Kick Plates 10” x 34”, BHMA 626, Grade 1 or approved equal

HAGER 194S-10”x34”, BHMA 626 or approved equal

6 Silencers Rubber or Vinyl

2 Door Closers Grade 1, Thru-bolted, LCN 4020N compensating

Series Smoothee or approved equal

2 Lever Handle Cylindrical

Locksets Curved Return Von Duprin, Series 992L w/ # 17 Lever

Design Option, Grade 1 or approved equal

2 Panic Bar Exit Device Grade 1, Von Duprin Series 99 CD9948L

Touch Bar or approved equal

2 Vertical Rod Sets Von Duprin Series 99 concealed vertical rod devices, Grade 1 or approved equal

4 Vertical Rod Mortise

Strike Plates Flush mortise strike plates top & bottom

2 Tri Base Floor Stop HAGER 295 F, Cast Brass, BHMA 626 finish, w/ Black Rubber Bumper, Grade 1 or approved equal

1 Threshold HAGAR, 417S, Finish A, 72” x 6” x 1/ 4” or approved equal, set in a bed of elastomeric sealant.

2 Door Bottom Sweeps Hager, 770S/B w/ nylon brush, Finish A, door width, Grade 1 or approved equal

2 Weather-stripping

Gasket Set Jambs and Head, Hager 863S, Finish X with

TPE Gasket or approved equal

2 Changeable Key Cores Steel Construction Key Cores, 7 Pin Best Lock

Compatible

1 Astragal set HAGAR, 845S/846S, Finish A, or approved equal, full door height

DOOR HARDWARE SCHEDULE, ALL RESTROOM DOORS

1 Stain Grade Solid Core Wood

Door, Light Oak Finish 1-3/ 4” x 3’-0” x 7’-0” in 16 gauge steel frame

1-1/2 Pair Full Mortise Hinges Ball Bearing Heavy Weight, Stainless Steel, 4-1/ 2” x 4-1/ 2” ANSI A5111, Grade 1

HAGER BB1199 BHMA 626 or approved equal

2 Kick Plates 10” x 34”, BHMA 626, Grade 1

HAGER 194S-10”x34”, BHMA 626 or approved

3 Silencers Rubber or Vinyl (not painted)

1 Door Closer Grade 1, Thru-bolted, LCN 4020N compensating

Series Smoothee or approved equal

1 Door Pull & Plate Hager Series 100, 101E, Stainless Steel, J407, Grade 1 or approved equal

1 Door Push Plate Hager, A30S, 1.6 mm, Stainless Steel, J301/J304, Grade 1 or approved equal

1 Lever Handle Cylindrical Curved Return Best Series 9K, Grade 1, ANSI F81

Lockset 93K 7 AB 14D S3 626 or approved equal

1 Tri Base Floor Stop HAGER 295 F, Cast Brass, BHMA 626 finish, w/ Black Rubber Bumper, Grade 1 or approved equal

1 Changeable Key Cores Steel Construction Key Cores, 7 Pin Best Lock

Compatible

SMALL FORMAT INTERCHANGABLE CORE – 7 PIN - TYPICAL

CURVED RETURN CYLINDRICAL LEVER HANDLE LOCKSET – TYPICAL

TOUCH BAR EXIT DEVICE WITH CONCEALED VERTICAL RODS, LEVER HANDLE AND

FLUSH MORTISE STRIKES

END OF SECTION - DOOR HARDWARE --