Attachment 19 - MEP Record Drawings.pdf

PDF 7 MB Posted

Attached to
MPLS208151 - Renovate Controlled Area, Building 9225 Federal contract opportunity
Solicitation number
FA301621B0001
Issued by
Department of the Air Force Air Education and Training Command

About this file

This solicitation is for design-build renovation services for a controlled area at Joint Base San Antonio Lackland Air Force Base. The project budget is between $500,000 and $1,000,000, and Davis-Bacon wage rates apply. This acquisition is set aside for women-owned small businesses. Offerors must be certified through the SBA WOSB program and documents verifying eligibility must be submitted with the initial offer. The solicitation requires offerors to complete identification blocks, pricing, and certifications on the SF1442 form. A detailed proposal and all supporting documentation as specified in the instructions must also be submitted. The response deadline is not provided.

View the file

Other files for this federal contract opportunity

Other files attached to MPLS208151 - Renovate Controlled Area, Building 9225, newest first.
File Type Posted
Site Visit Questions - Renovate Controlled Area - 26Mar2021.pdf PDF
Attachment 14 - Revised Wage Determination.pdf PDF
Attachment 01 - Revised Statement of Work 26 March 2021.pdf PDF
Attachment 04 - Revised Patch Panel and Multiple Input-Output (MIO)_Zone Boxes (Appendix D).pdf PDF
Attachment 7 - Revised Submittal Register 20210326.pdf PDF
Attachment 18 - Partial Mech.pdf PDF
FA301621B00010003.pdf PDF
Attachment 02 - Revised Concept Drawings (Appendix A).pdf PDF
Attachment 16 - Section L - Instructions to Offerors Rev 26Mar2021.pdf PDF
Site Visit Questions - Renovate Controlled Area - ANSWERED.docx DOCX document
FA301621B00010002.pdf PDF
FA301621B00010001.pdf PDF
FA301621B0001.pdf PDF
Attachment 09 - Asbestos Report.pdf PDF
Attachment 10 - Lead Based Paint Report.pdf PDF
Attachment 16 - Section L - Instructions to Offerors.pdf PDF
Attachment 05 - CAD_Templates_and_Reqs.zip ZIP file
Attachment 07 - Submittal Register.pdf PDF
Attachment 08 - DD1354.pdf PDF
Attachment 14 - Wage Determination.pdf PDF
Attachment 2 - Concept Drawings.pdf PDF
Attachment 03 - Labeling.pdf PDF
Attachment 11 - General Requirement for Obtaining Waste Manifest.pdf PDF
Attachment 1 - Statement of Work.pdf PDF
Attachment 04 - Patch Panel and Multiple Input-Output (MIO)_Zone Boxes.pdf PDF
Attachment 06 - Installation Guidelines.pdf PDF
Attachment 12 - Bldg 9225 Record Dwg Binder 20140711.pdf PDF
Attachment 13 - Climatological Data 2019 - 2020.pdf PDF
Attachment 15 - Construction Cost Estimate Breakdown.xls XLS spreadsheet
Attachment 17 - Section M - Evaluation Factors for Award.pdf PDF
Show all 30

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

U P

UP

OFFICE 341

CLASSROOM 328-329

CLASSROOM 340

MECHANICAL RM ROOF BELOW

CLASSROOM 310CLASSROOM 309

MEN

ELEC.

JAN.

WOMEN

ELEV

CORRIDOR CLASSROOM 311

CLASSROOM 312 C

H

AS

E

STORAGE 314 C

H

AS

E

STAIR 3

STORE ROOM 315STORE ROOM 316

OFFICE 317OFFICE 318

CLASSROOM 319

CORRIDOR 302

STORAGE 320A

STORAGE 320

OFFICE 321OFFICE 323

OFFICE 322

STAIR 2

COMM. 303

STORAGE 327

STORAGE 326

CLASSROOM)

CLASSROOM 313

V I F

STORE ROOM 315STORE ROOM 316

SWING SPACE

OFFICE 316 OFFICE 315

(TYP.)

(TYP.)

(TYP.)(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.) (TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

MEN

ELEC.

JAN.

WOMEN

ELEV

CORRIDOR

COMM.

(E)31/31 EA

RISER UP TO

(E)FAN

(E)16/16

(E)14/16

(E)16/8

(E)16/6

(E )6 "Ø H O T

AI

R

(E )8 "Ø C O

LD

A

IR

(E)

(E)22/16 EA

RISER FROM

SECOND

FLOOR

(E)6"Ø (E)6"Ø

(E)16/8

(E)

G

10 9 8 7 6 5 4 3 2 1

F

E

D

C

B

A

10 9 8 7 6 5 4 2 1

A

B

C

D

E

F

G

APPROVALDATEDESCRIPTIONZONESYMBOL

DATE:

PROJECT NUMBER

DRAWING NUMBER

DATE

SCALE: AS NOTED

BASE CIVIL ENGINEER

APPROVED

CHIEF ENGINEERING FLIGHT (CEC)

RECOMMENDED

CHIEF CONTRACTS SECTION (CECC)

RECOMMENDED

CONSTRUCTABILITY REVIEW (CECC2)

USING AGENCY

FIRE CHIEF (CEFS)

DESIGN TEAM

ENGINEER/DESIGNER

DRAWN BY

AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE

REVISIONS

MPLS 11-014

IN SHEETS, SHEET

DO NOT SCALE DRAWING

04 APRIL 2013

RRG

LA 11-0015

This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le wi thout the Archi tect 's e x p r e s s w r i t t e n p e r m i s s i o n .

11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL

12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL

02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL

03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL

04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL

04.30.2013GENERAL REVISION1

RECORD DRAWING

07-11-2014

THESE RECORD DRAWINGS HAVE

BEEN PREPARED, IN PART, ON THE

BASIS OF INFORMATION COMPILED

AND FURNISHED BY OTHERS. THE

ARCHITECT CANNOT ASSURE ITS

ACCURACY AND THEREFORE

CANNOT BE RESPONSIBLE FOR ANY

ERRORS OR OMISSIONS WHICH

HAVE BEEN INCORPORATED INTO

THIS DOCUMENT AS A RESULT.

01 RECORD DRAWING SUBMITTAL 03.10.2014

LACKLAND AIR FORCE BASE, TEXAS

37th TRAINING WING

REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO

LACKLAND AFB, TX

Velocity Con-Cor, LLC.

02 RECORD DRAWING SUBMITTAL 04.28.2014

03 RECORD DRAWING SUBMITTAL 05.23.2014

UP

OFFICE 341

CLASSROOM 328-329

CLASSROOM 340

MECHANICAL RM ROOF BELOW

CLASSROOM 310CLASSROOM 309

MEN

ELEC.

JAN.

WOMEN

ELEV

CORRIDOR CLASSROOM 311

CLASSROOM 312 C

H

AS

E

STORAGE 314 C

H

AS

E

STAIR 3

OFFICE 317OFFICE 318

CLASSROOM 319

CORRIDOR 302

SWING SPACE

OFFICE 321

SWING SPACE

OFFICE 323

SWING SPACE

OFFICE 322

SWING SPACE

(SWING SPACE

OFFICE 330

STAIR 2

COMM. 303

STORAGE 327

OFFICE 316 OFFICE 315

STORAGE 326

OFFICE 320

CLASSROOM)

CLASSROOM 313

V I F

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.) (TYP.)

(TYP.)

H/205H/205H/205H/205

H/165

H/165

J/1525 (TYP.

FOR 2)

E/775 (TYP.

FOR 4)

J/1495 (TYP.

FOR 2)

E/760 (TYP.

FOR 4)

J/1495 (TYP.

FOR 2)

E/760 (TYP.

FOR 4)

E/780 (TYP.

FOR 4)

J/1535 (TYP.

FOR 2)

H/165H/165

J/1850 (TYP.

FOR 2)

F/950 (TYP.

FOR 4)

N/300C/300C/300N/300

N/300N/300

C/300C/300

H/165

(TYP.)

(TYP.) J/1850 (TYP.

FOR 2)

F/950 (TYP.

FOR 4)

HC

CC

FAN

MEN

ELEC.

JAN.

WOMEN

ELEV

CORRIDOR

COMM.

(E )6 "Ø H O T

AI

R

(E )8 "Ø C O

LD

A

IR

(E)31/31 EA

RISER UP TO

EF-1

(E)14/16

(E)16/6

(E)22/16 EA

RISER FROM

SECOND

FLOOR

(E)6"Ø (E)6"Ø

(E)16/8

(E)16/16

POC

P/420

B/260

PROVIDE

PLASTER

FRAME

12/6

POC

B/165

PROVIDE

PLASTER

FRAME 12/6

POC

N/280

(E)

POC

12/6

G

10 9 8 7 6 5 4 3 2 1

F

E

D

C

B

A

10 9 8 7 6 5 4 2 1

A

B

C

D

E

F

G

APPROVALDATEDESCRIPTIONZONESYMBOL

DATE:

PROJECT NUMBER

DRAWING NUMBER

DATE

SCALE: AS NOTED

BASE CIVIL ENGINEER

APPROVED

CHIEF ENGINEERING FLIGHT (CEC)

RECOMMENDED

CHIEF CONTRACTS SECTION (CECC)

RECOMMENDED

CONSTRUCTABILITY REVIEW (CECC2)

USING AGENCY

FIRE CHIEF (CEFS)

DESIGN TEAM

ENGINEER/DESIGNER

DRAWN BY

AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE

REVISIONS

MPLS 11-014

IN SHEETS, SHEET

DO NOT SCALE DRAWING

04 APRIL 2013

RRG

LA 11-0015

This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le without the Architect 's e x p r e s s w r i t t e n p e r m i s s i o n .

11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL

12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL

02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL

03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL

04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL

04.30.2013GENERAL REVISION1

RECORD DRAWING

07-11-2014

THESE RECORD DRAWINGS HAVE

BEEN PREPARED, IN PART, ON THE

BASIS OF INFORMATION COMPILED

AND FURNISHED BY OTHERS. THE

ARCHITECT CANNOT ASSURE ITS

ACCURACY AND THEREFORE

CANNOT BE RESPONSIBLE FOR ANY

ERRORS OR OMISSIONS WHICH

HAVE BEEN INCORPORATED INTO

THIS DOCUMENT AS A RESULT.

01 RECORD DRAWING SUBMITTAL 03.10.2014

LACKLAND AIR FORCE BASE, TEXAS

37th TRAINING WING

REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO

LACKLAND AFB, TX

Velocity Con-Cor, LLC.

HWP-2 HWP-1

H C

C C

FAN

HWP-2 HWP-1

HWP-2 HWP-1

G

10 9 8 7 6 5 4 3 2 1

F

E

D

C

B

A

10 9 8 7 6 5 4 2 1

A

B

C

D

E

F

G

APPROVALDATEDESCRIPTIONZONESYMBOL

DATE:

PROJECT NUMBER

DRAWING NUMBER

DATE

SCALE: AS NOTED

BASE CIVIL ENGINEER

APPROVED

CHIEF ENGINEERING FLIGHT (CEC)

RECOMMENDED

CHIEF CONTRACTS SECTION (CECC)

RECOMMENDED

CONSTRUCTABILITY REVIEW (CECC2)

USING AGENCY

FIRE CHIEF (CEFS)

DESIGN TEAM

ENGINEER/DESIGNER

DRAWN BY

AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE

REVISIONS

MPLS 11-014

IN SHEETS, SHEET

DO NOT SCALE DRAWING

04 APRIL 2013

RRG

LA 11-0015

This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le without the Architect 's e x p r e s s w r i t t e n p e r m i s s i o n .

11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL

12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL

02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL

03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL

04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL

04.30.2013GENERAL REVISION1

RECORD DRAWING

07-11-2014

THESE RECORD DRAWINGS HAVE

BEEN PREPARED, IN PART, ON THE

BASIS OF INFORMATION COMPILED

AND FURNISHED BY OTHERS. THE

ARCHITECT CANNOT ASSURE ITS

ACCURACY AND THEREFORE

CANNOT BE RESPONSIBLE FOR ANY

ERRORS OR OMISSIONS WHICH

HAVE BEEN INCORPORATED INTO

THIS DOCUMENT AS A RESULT.

01 RECORD DRAWING SUBMITTAL 03.10.2014

LACKLAND AIR FORCE BASE, TEXAS

37th TRAINING WING

REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO

LACKLAND AFB, TX

Velocity Con-Cor, LLC.

MARK CFM

RANGE

NECK

SIZE THROWDAMPER LOCATION REMARKS

TMS, TYPE 3 FRAME

24"X24" MODULE

LAY-IN

CEILINGYES4W6"Ø5-160A

EF-1 3670 1.0" BELT 1076 200#REST

ROOMS

1.5/460/3 OCCUPANCYROOF

EXHAUST

UNIT SHALL BE U.L. LISTED, A.M.C.A. CERTIFIED AND

FURNISHED WITH BACKDRAFT DAMPER, ALUMINUM

BIRDSCREEN AND DISCONNECT SWITCH.

INSTALL FAN AT EXISTING ROOF CURB. PROVIDE CURB

ADAPTER AS REQUIRED.

EQUIVALENT MANUFACTURERS: GREENHECK, ACME,

BREIDERT AND PENN VENTILATOR

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

B

C

D

E

F

G

H

J

K

L

M

N

P

4W

4W

4W

4W

4W

4W

4W

YES

YES

(TITUS MODEL #)

SURFACE

SURFACE

SURFACE

WALL

WALL

WALL

165-280

285-450

455-685

690-860

865-985

165-280

375-1885

250-440

550-875

5-200

205-350

355-650

5-160

8"Ø

10"Ø

12"Ø

14"Ø

15"Ø

6"Ø

8"Ø

24"X24"

18"X6"

24"X8"

12"X6"

12"X12"

16"X16"

TMS, TYPE 3 FRAME

24"X24" MODULE

TMS, TYPE 3 FRAME

24"X24" MODULE

TMS, TYPE 3 FRAME

24"X24" MODULE

TMS, TYPE 3 FRAME

24"X24" MODULE

TMS, TYPE 3 FRAME

24"X24" MODULE

TMS, TYPE 3 FRAME

12"X12" MODULE

TMS, TYPE 1 FRAME

12"X12" MODULE

350RS, TYPE 3

BORDER;

24"X24"MODULE

3OORS

350RS

350RS

350RS

NOTES:

NOT ALL MARKS MAY BE USED.

ALL AIR DEVICES TO HAVE OFF WHITE FINISH.

PROVIDE 'TR' SQ TO ROU;ND ADAPTER REDUCER AS REQUIRED.

EQUIVALENT MANUFACTURERS: METAL-AIRE, ANEMOSTAT, KRUEGER, AND PRICE

ACE-195C8B

LAY-IN

CEILING

LAY-IN

CEILING

LAY-IN

CEILING

LAY-IN

CEILING

LAY-IN

CEILING

LAY-IN

CEILING

WALL 3OORS

Q - NO WALL440-560 18"X10" 350RS

G

10 9 8 7 6 5 4 3 2 1

F

E

D

C

B

A

10 9 8 7 6 5 4 2 1

A

B

C

D

E

F

G

APPROVALDATEDESCRIPTIONZONESYMBOL

DATE:

PROJECT NUMBER

DRAWING NUMBER

DATE

SCALE: AS NOTED

BASE CIVIL ENGINEER

APPROVED

CHIEF ENGINEERING FLIGHT (CEC)

RECOMMENDED

CHIEF CONTRACTS SECTION (CECC)

RECOMMENDED

CONSTRUCTABILITY REVIEW (CECC2)

USING AGENCY

FIRE CHIEF (CEFS)

DESIGN TEAM

ENGINEER/DESIGNER

DRAWN BY

AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE

REVISIONS

MPLS 11-014

IN SHEETS, SHEET

DO NOT SCALE DRAWING

04 APRIL 2013

RRG

LA 11-0015

This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le without the Architect 's e x p r e s s w r i t t e n p e r m i s s i o n .

11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL

12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL

02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL

03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL

04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL

04.30.2013GENERAL REVISION1

RECORD DRAWING

07-11-2014

THESE RECORD DRAWINGS HAVE

BEEN PREPARED, IN PART, ON THE

BASIS OF INFORMATION COMPILED

AND FURNISHED BY OTHERS. THE

ARCHITECT CANNOT ASSURE ITS

ACCURACY AND THEREFORE

CANNOT BE RESPONSIBLE FOR ANY

ERRORS OR OMISSIONS WHICH

HAVE BEEN INCORPORATED INTO

THIS DOCUMENT AS A RESULT.

01 RECORD DRAWING SUBMITTAL 03.10.2014

LACKLAND AIR FORCE BASE, TEXAS

37th TRAINING WING

REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO

LACKLAND AFB, TX

Velocity Con-Cor, LLC.

(E)EXTERNALLY WRAP

SHEET METAL SUPPLY

DUCT

EXISTING AIR DEVICE

SHALL BE REMOVED

AND REPLACED WITH

NEW

POC

EXISTING ROUND DUCT

TO REMAIN FOR

CONNECTION TO NEW

DIFFUSER. PROVIDE

DUCT TO RECONNECT TO

NEW AIR DEVICE AS

REQUIRED.

RESIL.

GROMMET

MOUNTED IN

SHT. MTL.

PANEL

DRIP

EDGE

2" X 2" WD.

BLOCKING BOLTED

TO MTL. CURB WITH

3/8" BOLTS AT 6"

O.C.

PREFABRICATED

MTL. CURB

AND CANT

POULTRY

NETTING FILL

BOX ABOVE

W/LOOSE

INSUL.

MTL.

DECK

TOP CHORD

OF BAR

JOIST

2-1/2" X 2-1/2" X 1/4"

STL. ANGLE HEADER

WELDED TO BAR

JOISTS

WD. BLOCKING

ANCHORED BY 1/2"

BOLTS @ 12" O.C.

CUT METAL DECK FOR

NEW PIPE

PENETRATION

RIGID

INSUL.

FLASHING

INTO

ROOFING

CONT.

CLEAT

CURB

FLASHING

CADMIUM PLATED

SCREWS

W/NEOPRENE

WASHERS AT 4" O.C.

SEE MECH./ELEC.

FOR PIPE SIZES

SHEET

METAL

WEATHER

HOOD

G

10 9 8 7 6 5 4 3 2 1

F

E

D

C

B

A

10 9 8 7 6 5 4 2 1

A

B

C

D

E

F

G

APPROVALDATEDESCRIPTIONZONESYMBOL

DATE:

PROJECT NUMBER

DRAWING NUMBER

DATE

SCALE: AS NOTED

BASE CIVIL ENGINEER

APPROVED

CHIEF ENGINEERING FLIGHT (CEC)

RECOMMENDED

CHIEF CONTRACTS SECTION (CECC)

RECOMMENDED

CONSTRUCTABILITY REVIEW (CECC2)

USING AGENCY

FIRE CHIEF (CEFS)

DESIGN TEAM

ENGINEER/DESIGNER

DRAWN BY

AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE

REVISIONS

MPLS 11-014

IN SHEETS, SHEET

DO NOT SCALE DRAWING

04 APRIL 2013

RRG

LA 11-0015

This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le without the Architect 's e x p r e s s w r i t t e n p e r m i s s i o n .

11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL

12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL

02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL

03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL

04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL

04.30.2013GENERAL REVISION1

RECORD DRAWING

07-11-2014

THESE RECORD DRAWINGS HAVE

BEEN PREPARED, IN PART, ON THE

BASIS OF INFORMATION COMPILED

AND FURNISHED BY OTHERS. THE

ARCHITECT CANNOT ASSURE ITS

ACCURACY AND THEREFORE

CANNOT BE RESPONSIBLE FOR ANY

ERRORS OR OMISSIONS WHICH

HAVE BEEN INCORPORATED INTO

THIS DOCUMENT AS A RESULT.

01 RECORD DRAWING SUBMITTAL 03.10.2014

LACKLAND AIR FORCE BASE, TEXAS

37th TRAINING WING

REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO

LACKLAND AFB, TX

Velocity Con-Cor, LLC.

OA

RA

SF-C

SF-S

SDR-1

SF VFD

LT-A

PFILT-S

SUPPLY

RETURN C A

B

CLG-O

C

C CD

SUPPLY

RETURNCA

B

RH-O

H

C

CD-T

DAPHI-A

L H

CD-P

LH

LOCATED 2/3 DOWN THE

LONGEST DUCT RUN

HD

HD-T

HD-P

LH

LOCATED 2/3 DOWN THE

LONGEST DUCT RUN

NC

OAD-O

SF-O

AHU 3 AND 4

DUAL DUCT UNITS

SEQUENCE OF OPERATION

SUPPLY FAN CONTROL: THE VARIABLE SPEED SUPPLY FAN WILL BE STARTED BASED ON OCCUPANCY SCHEDULE. WHEN THE SUPPLY FAN STATUS INDICATES THE FAN STARTED, THE CONTROL SEQUENCE WILL BE ENABLED. THE SUPPLY FAN WILL MODULATE TO MAINTAIN THE DISCHARGE STATIC PRESSURE, AS DETERMINED FROM THE MINIMUM OF THE HOT DECK AND COLD DECK DUCT STATIC PRESSURE SENSORS, AT

SETPOINT. UPON A LOSS OF AIRFLOW, THE SUPPLY FAN WILL AUTOMATICALLY RESTART.

OA CONTROL: THE OA DAMPER WILL OPEN WHEN AIR UNIT IS ENABLED UNDER OCCUPIED CONDITIONS AND

WILL CLOSE WHEN AREA IS UNOCCUPIED.

TEMPERATURE CONTROL: THE UNIT WILL CONTROL TO MAINTAIN A CONSTANT COLD DECK AND HOT DECK

DISCHARGE AIR TEMPERATURE.

OCCUPIED MODE: THE OCCUPANCY MODE WILL BE CONTROLLED VIA A NETWORK INPUT. THE OCCUPANCY

MODE CAN ALSO BE OVERRIDDEN BY A NETWORK INPUT.

UNOCCUPIED MODE: THE UNIT WILL REMAIN OFF DURING UNOCCUPIED PERIODS.

COLD DECK: THE COOLING COIL WILL MODULATE TO MAINTAIN THE COLD DECK TEMPERATURE SETPOINT.

WHEN THE UNIT IS SHUTDOWN, THE COOLING COIL WILL BE COMMANDED TO A PRESET POSITION SHOULD THE OUTDOOR AIR TEMPERATURE FALL BELOW THE LOW OUTDOOR AIR TEMPERATURE SETPOINT. UPON A

LOSS OF AIRFLOW, THE COOLING COIL WILL BE OFF.

HOT DECK: THE HOT DECK COIL WILL MODULATE TO MAINTAIN THE HOT DECK TEMPERATURE SETPOINT.

WHEN THE UNIT IS SHUTDOWN, THE HOT DECK COIL WILL BE COMMANDED TO A PRESET POSITION SHOULD THE OUTDOOR AIR TEMPERATURE FALL BELOW THE LOW OUTDOOR AIR TEMPERATURE SETPOINT. UPON A

LOSS OF AIRFLOW, THE HOT DECK COIL WILL REMAIN IN CONTROL.

PHWP2-C

PHWP2-S

PHWP1-C

PHWP1-S

HWS

HWR

OA-T

LOCATED IN THE SHADE ON THE

NORTH SIDE OF THE BUILDING

Boiler 1

BLR2LW-T

PHWR-T

NC C

MIX-O

NO

BLR1LW-T

PHWP2

Boiler 2

BLR1ISOV-S

BLR1ISOV-C

BLR2ISOV-C

BLR2ISOV-S

PHWP1

BLR1-EN

BLR1SP-O

BLR1-A

BLR1-S

BOILER 1 CONTROL

CABINET

BLR2-EN

BLR2SP-O

BLR2-A

BLR2-S

BOILER 2 CONTROL

CABINET

PHWP1 STARTER

PHWP2 STARTER

PHWS-T

HOT WATER SYSTEM

SEQUENCE OF OPERATION:

SYSTEM ENABLE: THE HEATING SYSTEM WILL AUTOMATICALLY

START WHEN THE SYSTEM ENABLE IS "ON". WHEN THE SYSTEM

ENABLE IS "OFF", THE HEATING SYSTEM WILL BE DISABLED.

BOILER CONTROL: THIS SYSTEM CONSISTS OF TWO BOILERS.

THE BURNERS SHALL BE CONTROLLED VIA THEIR OWN

INTERNAL CONTROLS. THE OUTDOOR AIR TEMPERATURE

SHALL DETERMINE THE NUMBER OF BOILERS RUNNING. A 3-

WAY MIXING VALVE SHALL MODULATE TO MAINTAIN SUPPLY

WATER TEMPERATURE DELIVERED TO THE BUILDING TO

SETPOINT AS RESET BY THE OUTDOOR AIR TEMPERATURE. THE

BOILER SETPOINT WILL BE CONTROLLED REMOTELY VIA THE

FMS. WHEN AN ADDITIONAL BOILER IS REQUIRED, THE BOILER

WITH THE LOWEST RUNTIME TOTAL SHALL BE ENABLED TO RUN.

THE BOILER ISOLATION VALVE WILL BE COMMANDED OPEN

PRIOR TO STARTING THE PUMP AND KEPT OPEN LONG ENOUGH

FOR THE PUMP TO COAST DOWN. IF THE STATUS OF THE

BOILER ISOLATION VALVE FAILS TO MATCH THE COMMAND, AN

ALARM WILL BE GENERATED AND THE NEXT BOILER IN

SEQUENCE WILL BE ENABLED.

HOT WATER PUMP CONTROL: WHEN ENABLED, A PUMP FOR

EACH BOILER WILL BE STARTED. AFTER THE BOILER IS

COMMANDED OFF, THE PUMP WILL CONTINUE TO RUN FOR A

SHORT TIME TO DISSIPATE THE HEAT. IF THE PUMP STATUS

DOES NOT MATCH THE COMMAND, AN ALARM WILL BE

GENERATED AND THE PUMP WILL BE STOPPED. UPON LOSS OF

STATUS, THE PUMP WILL RESTART AFTER THE SYSTEM RESET

IS ACTIVATED.

ADDITIONAL POINTS MONITORED BY THE FMS:

BOILER n STATUS (BLRn-S) BOILER n ALARM (BLRn-A) BOILER n LEAVING WATER TEMPERATURE (BLRnLW-T)

PRIMARY HW RETURN TEMPERATURE (PHWR-T)

OUTDOOR AIR TEMPERATURE (OA-T)

HWR

HWS

G

10 9 8 7 6 5 4 3 2 1

F

E

D

C

B

A

10 9 8 7 6 5 4 2 1

A

B

C

D

E

F

G

APPROVALDATEDESCRIPTIONZONESYMBOL

DATE:

PROJECT NUMBER

DRAWING NUMBER

DATE

SCALE: AS NOTED

BASE CIVIL ENGINEER

APPROVED

CHIEF ENGINEERING FLIGHT (CEC)

RECOMMENDED

CHIEF CONTRACTS SECTION (CECC)

RECOMMENDED

CONSTRUCTABILITY REVIEW (CECC2)

USING AGENCY

FIRE CHIEF (CEFS)

DESIGN TEAM

ENGINEER/DESIGNER

DRAWN BY

AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE

REVISIONS

MPLS 11-014

IN SHEETS, SHEET

DO NOT SCALE DRAWING

04 APRIL 2013

RRG

LA 11-0015

This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le without the Architect 's e x p r e s s w r i t t e n p e r m i s s i o n .

11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL

12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL

02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL

03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL

04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL

04.30.2013GENERAL REVISION1

RECORD DRAWING

07-11-2014

THESE RECORD DRAWINGS HAVE

BEEN PREPARED, IN PART, ON THE

BASIS OF INFORMATION COMPILED

AND FURNISHED BY OTHERS. THE

ARCHITECT CANNOT ASSURE ITS

ACCURACY AND THEREFORE

CANNOT BE RESPONSIBLE FOR ANY

ERRORS OR OMISSIONS WHICH

HAVE BEEN INCORPORATED INTO

THIS DOCUMENT AS A RESULT.

01 RECORD DRAWING SUBMITTAL 03.10.2014

LACKLAND AIR FORCE BASE, TEXAS

37th TRAINING WING

REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO

LACKLAND AFB, TX

Velocity Con-Cor, LLC.

UGE

UGT

ELECTRICAL SYMBOLS AND ABBREVIATIONS

ACS

I

PP

WAP

CAM

REX

ES

PB

EPB

DB

IC

DS

CCTV

PJ

I

SP

SP

T

DH

H

FF

D

J

R

C

J

F

DB

LC

FS

PS

FS

TS

TS

HD

GB

SD

DSD

A

V

AV

ML

MD

DC

CR

ANN

FAEX

FACP

SEC

ISC

AMP

G

10 9 8 7 6 5 4 3 2 1

F

E

D

C

B

A

10 9 8 7 6 5 4 2 1

A

B

C

D

E

F

G

APPROVALDATEDESCRIPTIONZONESYMBOL

DATE:

PROJECT NUMBER

DRAWING NUMBER

DATE

SCALE: AS NOTED

BASE CIVIL ENGINEER

APPROVED

CHIEF ENGINEERING FLIGHT (CEC)

RECOMMENDED

CHIEF CONTRACTS SECTION (CECC)

RECOMMENDED

CONSTRUCTABILITY REVIEW (CECC2)

USING AGENCY

FIRE CHIEF (CEFS)

DESIGN TEAM

ENGINEER/DESIGNER

DRAWN BY

AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE

REVISIONS

MPLS 11-014

IN SHEETS, SHEET

DO NOT SCALE DRAWING

04 APRIL 2013

RRG

LA 11-0015

This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le wi thout the Archi tect 's e x p r e s s w r i t t e n p e r m i s s i o n .

11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL

12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL

02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL

03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL

04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL

04.30.2013GENERAL REVISION1

RECORD DRAWING

07-11-2014

THESE RECORD DRAWINGS HAVE

BEEN PREPARED, IN PART, ON THE

BASIS OF INFORMATION COMPILED

AND FURNISHED BY OTHERS. THE

ARCHITECT CANNOT ASSURE ITS

ACCURACY AND THEREFORE

CANNOT BE RESPONSIBLE FOR ANY

ERRORS OR OMISSIONS WHICH

HAVE BEEN INCORPORATED INTO

THIS DOCUMENT AS A RESULT.

01 RECORD DRAWING SUBMITTAL 03.10.2014

LACKLAND AIR FORCE BASE, TEXAS

37th TRAINING WING

REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO

LACKLAND AFB, TX

Velocity Con-Cor, LLC.

UP

CLASSROOM 310CLASSROOM 309

MEN

ELEC.

JAN.

WOMEN

ELEV

CORRIDOR CLASSROOM 311

CLASSROOM 312 C

H

AS

E

STORAGE 314 C

H

AS

E

STAIR 3

STORE ROOM 315STORE ROOM 316

OFFICE 317OFFICE 318

CLASSROOM 319

CORRIDOR 302

STORAGE 320A

STORAGE 320

OFFICE 321OFFICE 323

OFFICE 322

STAIR 2

COMM. 303

STORAGE 327

STORAGE 326

CLASSROOM)

CLASSROOM 313

V I F

STORE ROOM 315STORE ROOM 316

SWING SPACE

OFFICE 316 OFFICE 315

G

10 9 8 7 6 5 4 3 2 1

F

E

D

C

B

A

10 9 8 7 6 5 4 2 1

A

B

C

D

E

F

G

APPROVALDATEDESCRIPTIONZONESYMBOL

DATE:

PROJECT NUMBER

DRAWING NUMBER

DATE

SCALE: AS NOTED

BASE CIVIL ENGINEER

APPROVED

CHIEF ENGINEERING FLIGHT (CEC)

RECOMMENDED

CHIEF CONTRACTS SECTION (CECC)

RECOMMENDED

CONSTRUCTABILITY REVIEW (CECC2)

USING AGENCY

FIRE CHIEF (CEFS)

DESIGN TEAM

ENGINEER/DESIGNER

DRAWN BY

AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE

REVISIONS

MPLS 11-014

IN SHEETS, SHEET

DO NOT SCALE DRAWING

04 APRIL 2013

RRG

LA 11-0015

This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le without the Architect 's e x p r e s s w r i t t e n p e r m i s s i o n .

11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL

12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL

02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL

03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL

04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL

04.30.2013GENERAL REVISION1

RECORD DRAWING

07-11-2014

THESE RECORD DRAWINGS HAVE

BEEN PREPARED, IN PART, ON THE

BASIS OF INFORMATION COMPILED

AND FURNISHED BY OTHERS. THE

ARCHITECT CANNOT ASSURE ITS

ACCURACY AND THEREFORE

CANNOT BE RESPONSIBLE FOR ANY

ERRORS OR OMISSIONS WHICH

HAVE BEEN INCORPORATED INTO

THIS DOCUMENT AS A RESULT.

01 RECORD DRAWING SUBMITTAL 03.10.2014

LACKLAND AIR FORCE BASE, TEXAS

37th TRAINING WING

REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO

LACKLAND AFB, TX

Velocity Con-Cor, LLC.

UP

CLASSROOM 310CLASSROOM 309

MEN

ELEC.

JAN.

WOMEN

ELEV

CORRIDOR CLASSROOM 311

CLASSROOM 312 C

H

AS

E

STORAGE 314 C

H

AS

E

STAIR 3

STORE ROOM 315STORE ROOM 316

OFFICE 317OFFICE 318

CLASSROOM 319

CORRIDOR 302

STORAGE 320A

STORAGE 320

OFFICE 321OFFICE 323

OFFICE 322

STAIR 2

COMM. 303

STORAGE 327

STORAGE 326

CLASSROOM)

CLASSROOM 313

V I F

STORE ROOM 315STORE ROOM 316

SWING SPACE

OFFICE 316 OFFICE 315

G

10 9 8 7 6 5 4 3 2 1

F

E

D

C

B

A

10 9 8 7 6 5 4 2 1

A

B

C

D

E

F

G

APPROVALDATEDESCRIPTIONZONESYMBOL

DATE:

PROJECT NUMBER

DRAWING NUMBER

DATE

SCALE: AS NOTED

BASE CIVIL ENGINEER

APPROVED

CHIEF ENGINEERING FLIGHT (CEC)

RECOMMENDED

CHIEF CONTRACTS SECTION (CECC)

RECOMMENDED

CONSTRUCTABILITY REVIEW (CECC2)

USING AGENCY

FIRE CHIEF (CEFS)

DESIGN TEAM

ENGINEER/DESIGNER

DRAWN BY

AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE

REVISIONS

MPLS 11-014

IN SHEETS, SHEET

DO NOT SCALE DRAWING

04 APRIL 2013

RRG

LA 11-0015

This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le wi thout the Archi tect 's e x p r e s s w r i t t e n p e r m i s s i o n .

11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL

12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL

02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL

03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL

04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL

04.30.2013GENERAL REVISION1

RECORD DRAWING

07-11-2014

THESE RECORD DRAWINGS HAVE

BEEN PREPARED, IN PART, ON THE

BASIS OF INFORMATION COMPILED

AND FURNISHED BY OTHERS. THE

ARCHITECT CANNOT ASSURE ITS

ACCURACY AND THEREFORE

CANNOT BE RESPONSIBLE FOR ANY

ERRORS OR OMISSIONS WHICH

HAVE BEEN INCORPORATED INTO

THIS DOCUMENT AS A RESULT.

01 RECORD DRAWING SUBMITTAL 03.10.2014

LACKLAND AIR FORCE BASE, TEXAS

37th TRAINING WING

REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO

LACKLAND AFB, TX

Velocity Con-Cor, LLC.

UP

CLASSROOM 310CLASSROOM 309

MEN

ELEC.

JAN.

WOMEN

ELEV

CORRIDOR CLASSROOM 311

CLASSROOM 312 C

H

AS

E

STORAGE 314 C

H

AS

E

STAIR 3

STORE ROOM 315STORE ROOM 316

OFFICE 317OFFICE 318

CLASSROOM 319

CORRIDOR 302

STORAGE 320A

STORAGE 320

OFFICE 321OFFICE 323

OFFICE 322

STAIR 2

COMM. 303

STORAGE 327

STORAGE 326

CLASSROOM)

CLASSROOM 313

V I F

STORE ROOM 315STORE ROOM 316

SWING SPACE

OFFICE 316 OFFICE 315

G

10 9 8 7 6 5 4 3 2 1

F

E

D

C

B

A

10 9 8 7 6 5 4 2 1

A

B

C

D

E

F

G

APPROVALDATEDESCRIPTIONZONESYMBOL

DATE:

PROJECT NUMBER

DRAWING NUMBER

DATE

SCALE: AS NOTED

BASE CIVIL ENGINEER

APPROVED

CHIEF ENGINEERING FLIGHT (CEC)

RECOMMENDED

CHIEF CONTRACTS SECTION (CECC)

RECOMMENDED

CONSTRUCTABILITY REVIEW (CECC2)

USING AGENCY

FIRE CHIEF (CEFS)

DESIGN TEAM

ENGINEER/DESIGNER

DRAWN BY

AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE

REVISIONS

MPLS 11-014

IN SHEETS, SHEET

DO NOT SCALE DRAWING

04 APRIL 2013

RRG

LA 11-0015

This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le wi thout the Archi tect 's e x p r e s s w r i t t e n p e r m i s s i o n .

11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL

12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL

02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL

03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL

04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL

04.30.2013GENERAL REVISION1

RECORD DRAWING

07-11-2014

THESE RECORD DRAWINGS HAVE

BEEN PREPARED, IN PART, ON THE

BASIS OF INFORMATION COMPILED

AND FURNISHED BY OTHERS. THE

ARCHITECT CANNOT ASSURE ITS

ACCURACY AND THEREFORE

CANNOT BE RESPONSIBLE FOR ANY

ERRORS OR OMISSIONS WHICH

HAVE BEEN INCORPORATED INTO

THIS DOCUMENT AS A RESULT.

01 RECORD DRAWING SUBMITTAL 03.10.2014

LACKLAND AIR FORCE BASE, TEXAS

37th TRAINING WING

REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO

LACKLAND AFB, TX

Velocity Con-Cor, LLC.

UP

CLASSROOM 310CLASSROOM 309

MEN

ELEC.

JAN.

WOMEN

ELEV

CORRIDOR CLASSROOM 311

CLASSROOM 312 C

H

AS

E

STORAGE 314 C

H

AS

E

STAIR 3

OFFICE 317OFFICE 318

CLASSROOM 319

CORRIDOR 302

SWING SPACE

OFFICE 321

SWING SPACE

OFFICE 323

SWING SPACE

OFFICE 322

SWING SPACE

(SWING SPACE

STAIR 2

COMM. 303

STORAGE 327

OFFICE 316 OFFICE 315

STORAGE 326

OFFICE 320

CLASSROOM)

CLASSROOM 313

V I F

72/20

XCR72

O

SERA

KRUG

TABLE

O

OO

6910-18D-29

G

10 9 8 7 6 5 4 3 2 1

F

E

D

C

B

A

10 9 8 7 6 5 4 2 1

A

B

C

D

E

F

G

APPROVALDATEDESCRIPTIONZONESYMBOL

DATE:

PROJECT NUMBER

DRAWING NUMBER

DATE

SCALE: AS NOTED

BASE CIVIL ENGINEER

APPROVED

CHIEF ENGINEERING FLIGHT (CEC)

RECOMMENDED

CHIEF CONTRACTS SECTION (CECC)

RECOMMENDED

CONSTRUCTABILITY REVIEW (CECC2)

USING AGENCY

FIRE CHIEF (CEFS)

DESIGN TEAM

ENGINEER/DESIGNER

DRAWN BY

AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE

REVISIONS

MPLS 11-014

IN SHEETS, SHEET

DO NOT SCALE DRAWING

04 APRIL 2013

RRG

LA 11-0015

This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le without the Architect 's e x p r e s s w r i t t e n p e r m i s s i o n .

11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL

12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL

02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL

03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL

04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL

04.30.2013GENERAL REVISION1

RECORD DRAWING

07-11-2014

THESE RECORD DRAWINGS HAVE

BEEN PREPARED, IN PART, ON THE

BASIS OF INFORMATION COMPILED

AND FURNISHED BY OTHERS. THE

ARCHITECT CANNOT ASSURE ITS

ACCURACY AND THEREFORE

CANNOT BE RESPONSIBLE FOR ANY

ERRORS OR OMISSIONS WHICH

HAVE BEEN INCORPORATED INTO

THIS DOCUMENT AS A RESULT.

01 RECORD DRAWING SUBMITTAL 03.10.2014

LACKLAND AIR FORCE BASE, TEXAS

37th TRAINING WING

REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO

LACKLAND AFB, TX

Velocity Con-Cor, LLC.

UP

CLASSROOM 310CLASSROOM 309

MEN

ELEC.

JAN.

WOMEN

ELEV

CORRIDOR CLASSROOM 311

CLASSROOM 312 C

H

AS

E

STORAGE 314 C

H

AS

E

STAIR 3

OFFICE 317OFFICE 318

CLASSROOM 319

CORRIDOR 302

SWING SPACE

OFFICE 321

SWING SPACE

OFFICE 323

SWING SPACE

OFFICE 322

SWING SPACE

(SWING SPACE

STAIR 2

COMM. 303

STORAGE 327

OFFICE 316 OFFICE 315

STORAGE 326

OFFICE 320

CLASSROOM)

CLASSROOM 313

V I F

72/20

XCR72

O

/7

5/

L

42/87/66L

/7

5/

L

SERA

KRUG

TABLE

O

/7

5/

L

/7

5/

L

OO

6910-18D-29

G

10 9 8 7 6 5 4 3 2 1

F

E

D

C

B

A

10 9 8 7 6 5 4 2 1

A

B

C

D

E

F

G

APPROVALDATEDESCRIPTIONZONESYMBOL

DATE:

PROJECT NUMBER

DRAWING NUMBER

DATE

SCALE: AS NOTED

BASE CIVIL ENGINEER

APPROVED

CHIEF ENGINEERING FLIGHT (CEC)

RECOMMENDED

CHIEF CONTRACTS SECTION (CECC)

RECOMMENDED

CONSTRUCTABILITY REVIEW (CECC2)

USING AGENCY

FIRE CHIEF (CEFS)

DESIGN TEAM

ENGINEER/DESIGNER

DRAWN BY

AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE

REVISIONS

MPLS 11-014

IN SHEETS, SHEET

DO NOT SCALE DRAWING

04 APRIL 2013

RRG

LA 11-0015

This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le without the Architect 's e x p r e s s w r i t t e n p e r m i s s i o n .

11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL

12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL

02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL

03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL

04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL

04.30.2013GENERAL REVISION1

RECORD DRAWING

07-11-2014

THESE RECORD DRAWINGS HAVE

BEEN PREPARED, IN PART, ON THE

BASIS OF INFORMATION COMPILED

AND FURNISHED BY OTHERS. THE

ARCHITECT CANNOT ASSURE ITS

ACCURACY AND THEREFORE

CANNOT BE RESPONSIBLE FOR ANY

ERRORS OR OMISSIONS WHICH

HAVE BEEN INCORPORATED INTO

THIS DOCUMENT AS A RESULT.

01 RECORD DRAWING SUBMITTAL 03.10.2014

LACKLAND AIR FORCE BASE, TEXAS

37th TRAINING WING

REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO

LACKLAND AFB, TX

Velocity Con-Cor, LLC.

UP

CLASSROOM 310CLASSROOM 309

MEN

ELEC.

JAN.

WOMEN

ELEV

CORRIDOR CLASSROOM 311

CLASSROOM 312 C

H

AS

E

STORAGE 314 C

H

AS

E

STAIR 3

OFFICE 317OFFICE 318

CLASSROOM 319

CORRIDOR 302

SWING SPACE

OFFICE 321

SWING SPACE

OFFICE 323

SWING SPACE

OFFICE 322

SWING SPACE

(SWING SPACE

STAIR 2

COMM. 303

STORAGE 327

OFFICE 316 OFFICE 315

STORAGE 326

OFFICE 320

CLASSROOM)

CLASSROOM 313

V I F

72/20

XCR72

O

/7

5/

L

42/87/66L

/7

5/

L

SERA

KRUG

TABLE

O

/7

5/

L

/7

5/

L

OO

6910-18D-29

G

10 9 8 7 6 5 4 3 2 1

F

E

D

C

B

A

10 9 8 7 6 5 4 2 1

A

B

C

D

E

F

G

APPROVALDATEDESCRIPTIONZONESYMBOL

DATE:

PROJECT NUMBER

DRAWING NUMBER

DATE

SCALE: AS NOTED

BASE CIVIL ENGINEER

APPROVED

CHIEF ENGINEERING FLIGHT (CEC)

RECOMMENDED

CHIEF CONTRACTS SECTION (CECC)

RECOMMENDED

CONSTRUCTABILITY REVIEW (CECC2)

USING AGENCY

FIRE CHIEF (CEFS)

DESIGN TEAM

ENGINEER/DESIGNER

DRAWN BY

AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE

REVISIONS

MPLS 11-014

IN SHEETS, SHEET

DO NOT SCALE DRAWING

04 APRIL 2013

RRG

LA 11-0015

This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le without the Architect 's e x p r e s s w r i t t e n p e r m i s s i o n .

11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL

12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL

02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL

03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL

04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL

04.30.2013GENERAL REVISION1

RECORD DRAWING

07-11-2014

THESE RECORD DRAWINGS HAVE

BEEN PREPARED, IN PART, ON THE

BASIS OF INFORMATION COMPILED

AND FURNISHED BY OTHERS. THE

ARCHITECT CANNOT ASSURE ITS

ACCURACY AND THEREFORE

CANNOT BE RESPONSIBLE FOR ANY

ERRORS OR OMISSIONS WHICH

HAVE BEEN INCORPORATED INTO

THIS DOCUMENT AS A RESULT.

01 RECORD DRAWING SUBMITTAL 03.10.2014

LACKLAND AIR FORCE BASE, TEXAS

37th TRAINING WING

REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO

LACKLAND AFB, TX

Velocity Con-Cor, LLC.

EXISTING ELECTRONIC GRADE DISTRIBUTION PANEL "#1",

208Y/120V, 60Hz, 1600A, 3PH., 4W., N1 ENCLOSED

1600/3

200/3

4F

225/3

4C

EXISTING ELECTRONIC GRADE DISTRIBUTION PANEL "#4",

208Y/120V, 60Hz, 1600A, 3PH., 4W., N1 ENCLOSED

1600/3

200/3

6F

225/3

6C

3000/3

1600/3

1600/3

EXISTING LOW VOLTAGE SWITCHGEAR

EXISTING SERVICE ENTRANCE

200/3

4J

6C 200/3

100/3

6C

EXISTING ELECTRONIC GRADE DISTRIBUTION PANEL "#2",

208Y/120V, 60Hz, 200A, 3PH., 4W., N1 ENCLOSED

G

10 9 8 7 6 5 4 3 2 1

F

E

D

C

B

A

10 9 8 7 6 5 4 2 1

A

B

C

D

E

F

G

APPROVALDATEDESCRIPTIONZONESYMBOL

DATE:

PROJECT NUMBER

DRAWING NUMBER

DATE

SCALE: AS NOTED

BASE CIVIL ENGINEER

APPROVED

CHIEF ENGINEERING FLIGHT (CEC)

RECOMMENDED

CHIEF CONTRACTS SECTION (CECC)

RECOMMENDED

CONSTRUCTABILITY REVIEW (CECC2)

USING AGENCY

FIRE CHIEF (CEFS)

DESIGN TEAM

ENGINEER/DESIGNER

DRAWN BY

AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE

REVISIONS

MPLS 11-014

IN SHEETS, SHEET

DO NOT SCALE DRAWING

04 APRIL 2013

RRG

LA 11-0015

This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le wi thout the Archi tect 's e x p r e s s w r i t t e n p e r m i s s i o n .

11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL

12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL

02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL

03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL

04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL

04.30.2013GENERAL REVISION1

RECORD DRAWING

07-11-2014

THESE RECORD DRAWINGS HAVE

BEEN PREPARED, IN PART, ON THE

BASIS OF INFORMATION COMPILED

AND FURNISHED BY OTHERS. THE

ARCHITECT CANNOT ASSURE ITS

ACCURACY AND THEREFORE

CANNOT BE RESPONSIBLE FOR ANY

ERRORS OR OMISSIONS WHICH

HAVE BEEN INCORPORATED INTO

THIS DOCUMENT AS A RESULT.

01 RECORD DRAWING SUBMITTAL 03.10.2014

LACKLAND AIR FORCE BASE, TEXAS

37th TRAINING WING

REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO

LACKLAND AFB, TX

Velocity Con-Cor, LLC.

G

10 9 8 7 6 5 4 3 2 1

F

E

D

C

B

A

10 9 8 7 6 5 4 2 1

A

B

C

D

E

F

G

APPROVALDATEDESCRIPTIONZONESYMBOL

DATE:

PROJECT NUMBER

DRAWING NUMBER

DATE

SCALE: AS NOTED

BASE CIVIL ENGINEER

APPROVED

CHIEF ENGINEERING FLIGHT (CEC)

RECOMMENDED

CHIEF CONTRACTS SECTION (CECC)

RECOMMENDED

CONSTRUCTABILITY REVIEW (CECC2)

USING AGENCY

FIRE CHIEF (CEFS)

DESIGN TEAM

ENGINEER/DESIGNER

DRAWN BY

AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE

REVISIONS

MPLS 11-014

IN SHEETS, SHEET

DO NOT SCALE DRAWING

04 APRIL 2013

RRG

LA 11-0015

This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le wi thout the Archi tect 's e x p r e s s w r i t t e n p e r m i s s i o n .

11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL

12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL

02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL

03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL

04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL

04.30.2013GENERAL REVISION1

RECORD DRAWING

07-11-2014

THESE RECORD DRAWINGS HAVE

BEEN PREPARED, IN PART, ON THE

BASIS OF INFORMATION COMPILED

AND FURNISHED BY OTHERS. THE

ARCHITECT CANNOT ASSURE ITS

ACCURACY AND THEREFORE

CANNOT BE RESPONSIBLE FOR ANY

ERRORS OR OMISSIONS WHICH

HAVE BEEN INCORPORATED INTO

THIS DOCUMENT AS A RESULT.

01 RECORD DRAWING SUBMITTAL 03.10.2014

LACKLAND AIR FORCE BASE, TEXAS

37th TRAINING WING

REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO

LACKLAND AFB, TX

Velocity Con-Cor, LLC.

10 9 8 7 6 5 4 3 2 1

F

E

D

C

B

A

10 9 8 7 6 5 4 2 1

A

B

C

D

E

F

G

APPROVALDATEDESCRIPTIONZONESYMBOL

DATE:

PROJECT NUMBER

DRAWING NUMBER

DATE

SCALE: AS NOTED

BASE CIVIL ENGINEER

APPROVED

CHIEF ENGINEERING FLIGHT (CEC)

RECOMMENDED

CHIEF CONTRACTS SECTION (CECC)

RECOMMENDED

CONSTRUCTABILITY REVIEW (CECC2)

USING AGENCY

FIRE CHIEF (CEFS)

DESIGN TEAM

ENGINEER/DESIGNER

DRAWN BY

AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE

REVISIONS

MPLS 11-014

IN SHEETS, SHEET

DO NOT SCALE DRAWING

04 APRIL 2013

RRG

LA 11-0015

This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le without the Architect 's e x p r e s s w r i t t e n p e r m i s s i o n .

11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL

12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL

02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL

03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL

04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL

04.30.2013GENERAL REVISION1

RECORD DRAWING

07-11-2014

THESE RECORD DRAWINGS HAVE

BEEN PREPARED, IN PART, ON THE

BASIS OF INFORMATION COMPILED

AND FURNISHED BY OTHERS. THE

ARCHITECT CANNOT ASSURE ITS

ACCURACY AND THEREFORE

CANNOT BE RESPONSIBLE FOR ANY

ERRORS OR OMISSIONS WHICH

HAVE BEEN INCORPORATED INTO

THIS DOCUMENT AS A RESULT.

01 RECORD DRAWING SUBMITTAL 03.10.2014

LACKLAND AIR FORCE BASE, TEXAS

37th TRAINING WING

REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO

LACKLAND AFB, TX

Velocity Con-Cor, LLC.

MEN

ELEC.

JAN.

WOMEN

ELEV

CORRIDOR

COMM.

(E)FD

(E)3"FCO

(E)4"V RISER; SEE

1/P-401 FOR

CONTINUATION;

(E)4"VTR

(E)2"V RISER; SEE

1/P-401 FOR

CONTINUATION;

(E)2"VTR

(E)2"SS DROP; SEE

1/P-401 FOR

CONTINUATION

(E)FD

(E)6"V RISER; SEE 1/P-401

FOR CONTINUATION

(E)CAP

(E)2"SS DROP; SEE

1/P-401 FOR

CONTINUATION

(E)2"V RISER; SEE

1/P-401 FOR

CONTINUATION;

(E)2"VTR

(E)2"SS DROP; SEE

1/P-401 FOR

CONTINUATION

(E)6"SS DROP; 1/P-401 FOR

CONTINUATION

(E)3"

(E)4"

(E)3"

(E)4"V

(E)4"(E)3"

(E)2"V

(E)4"

(E)4" (TYP.

FOR 4)

(E)2"V

(E)4"V

(E)4"V

(E)3"

(E)4"V

(E)2"

(E)2" (E)1-1/4"

(E)1-1/4"

(E)4"V

(E)2"V

(E)2"V

(E)4"V

(E)4"V

(E)4"SS DROP; SEE

1/P-401 FOR

CONTINUATION; (E)4"V

FROM TOP OF (E)4"SS

STACK

(E)2" (TYP.

FOR 5)

(E)2" (TYP.

FOR 4)

(E)4"V

(E)4"V

(E)3"

(E)4"V

(E)4"V

(E)3"

(E)3"

(E)2"

(E)1-1/4"V

(E)1-1/2"V

(E)2"

(E)1-1/4"V

(TYP. FOR 4)

(E)2"V

(E)2"V

(E)4"

(E)2"V

CAP

CAP

CAP

CAP

CAP

CAP

CAP

CAP

CAP

CAP

(E)4"

(E)4"

(E)4"V

(E)4"V

(E)3"

(E)1-1/2"CW RISER; SEE

2/P-401 FOR

CONTINUATION

(E)1"HW RISER; SEE

2/P-401 FOR

CONTINUATION

(E)1/2"CW RISER; SEE

2/P-401 FOR

CONTINUATION

(E)3/4"HWR; SEE 2/P-401

FOR CONTINUATION

(E)2"CW RISER; SEE

2/P-401 FOR

CONTINUATION

(E)1-1/2"HW RISER; SEE

2/P-401 FOR

CONTINUATION

(E)1/2"CW RISER; SEE

2/P-401 FOR

CONTINUATION

(E)1"

(E)1"

(E)1"

(E)1-1/4"

(E)1"

(E)1/2"

(E)1"

(E)FD

(E)1/2" (TYP. FOR 5)

(E)1-1/4"

(TYP. FOR 4)

(E)1" (TYP.

FOR 4)

(E)1/2" (TYP. FOR 5)

(E)1/2" (TYP.

FOR 2)

(E)1/2" (TYP.

FOR 2)

(E)1-1/4" (TYP. FOR 2)

(E)1"

(E)1-1/2"

(E)1-1/2"

(E)1-1/2"

(E)2"

(E)CAP

(E)CAP

(E)3/4"

(E)1-1/4"

(E)1-1/4"

(E)3/4"

(E)1/2"

(E)1-1/4"

(E)1-1/2"

(E)1-1/4"

(E)1-1/4"

(E)1-1/2"

CAP

CAP

CAP

CAPCAP

CAP

CAP

CLASSROOM 309

MEN

ELEC.

JAN.

WOMEN

ELEV

CORRIDOR

COMM.

G

10 9 8 7 6 5 4 3 2 1

F

E

D

C

B

A

10 9 8 7 6 5 4 2 1

A

B

C

D

E

F

G

APPROVALDATEDESCRIPTIONZONESYMBOL

DATE:

PROJECT NUMBER

DRAWING NUMBER

DATE

SCALE: AS NOTED

BASE CIVIL ENGINEER

APPROVED

CHIEF ENGINEERING FLIGHT (CEC)

RECOMMENDED

CHIEF CONTRACTS SECTION (CECC)

RECOMMENDED

CONSTRUCTABILITY REVIEW (CECC2)

USING AGENCY

FIRE CHIEF (CEFS)

DESIGN TEAM

ENGINEER/DESIGNER

DRAWN BY

AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE

REVISIONS

MPLS 11-014

IN SHEETS, SHEET

DO NOT SCALE DRAWING

04 APRIL 2013

RRG

LA 11-0015

This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le wi thout the Archi tect 's e x p r e s s w r i t t e n p e r m i s s i o n .

11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL

12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL

02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL

03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL

04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL

04.30.2013GENERAL REVISION1

RECORD DRAWING

07-11-2014

THESE RECORD DRAWINGS HAVE

BEEN PREPARED, IN PART, ON THE

BASIS OF INFORMATION COMPILED

AND FURNISHED BY OTHERS. THE

ARCHITECT CANNOT ASSURE ITS

ACCURACY AND THEREFORE

CANNOT BE RESPONSIBLE FOR ANY

ERRORS OR OMISSIONS WHICH

HAVE BEEN INCORPORATED INTO

THIS DOCUMENT AS A RESULT.

01 RECORD DRAWING SUBMITTAL 03.10.2014

LACKLAND AIR FORCE BASE, TEXAS

37th TRAINING WING

REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO

LACKLAND AFB, TX

Velocity Con-Cor, LLC.

CLASSROOM 309

MEN

ELEC.

JAN.

WOMEN

ELEV

CORRIDOR

COMM.

(E)4"V RISER; (E)4"VTR

(E)2"V RISER;

(E)2"VTR

(E)2"SS DROP

(E)6"V RISER

(E)2"SS DROP

(E)2"V RISER;

(E)2"VTR

(E)2"SS DROP; SEE

1/DP1 FOR

CONTINUATION

(E)6"SS DROP

(E)2"

(E)1-1/4"

(E)1-1/4"

(E)2"V

(E)FD

(E)4"

(E)4"

(E)2"

(E)4"V

(E)4"V

(E)4"SS; (E)4"V FROM

TOP OF (E)4"SS STACK

(E)4"V

(E)2"V

(E)4"V

(E)3"

(E)1-1/2"V

(E)3"

POC

POC

POC

POC; 2"

1-1/2"V (E)3"

(E)4"V (E)3"

(E)4"V

4" ABOVE

FLOOR

4" ABOVE

FLOOR

2"SS DROP THRU

FLOOR; CORE

DRILL AS

REQUIRED

WCO

POC

(E)4"

2"

4" ABOVE

FLOOR

4" ABOVE

FLOOR

POC

POC

POC

POC

POC

POC

POC

POC

POC

POC

POC

POC

TRAP PRIMER

LINE BELOW

FLOOR

PROVIDE TRAP

PRIMER

CONNECTION ON

SINK TAILPIECE

CLASSROOM 309

MEN

ELEC.

JAN.

WOMEN

ELEV

CORRIDOR

COMM.

(E)1/2"CW RISER

(E)FD

(E)1-1/2"

POC; 3/4"

3/4"

WHA-A

WHA-B

12" X 12" WALL

ACCESS PANEL

AP

12" X 12" WALL

ACCESS PANEL

AP

WHA-A

WHA-C

POC

POC

POC

POC

POC

POC

POC

POC

POC

POC

POC

POC

POC

TRAP PRIMER

LINE BELOW

FLOOR

PROVIDE TRAP

PRIMER

CONNECTION ON

SINK TAILPIECE

G

10 9 8 7 6 5 4 3 2 1

F

E

D

C

B

A

10 9 8 7 6 5 4 2 1

A

B

C

D

E

F

G

APPROVALDATEDESCRIPTIONZONESYMBOL

DATE:

PROJECT NUMBER

DRAWING NUMBER

DATE

SCALE: AS NOTED

BASE CIVIL ENGINEER

APPROVED

CHIEF ENGINEERING FLIGHT (CEC)

RECOMMENDED

CHIEF CONTRACTS SECTION (CECC)

RECOMMENDED

CONSTRUCTABILITY REVIEW (CECC2)

USING AGENCY

FIRE CHIEF (CEFS)

DESIGN TEAM

ENGINEER/DESIGNER

DRAWN BY

AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE

REVISIONS

MPLS 11-014

IN SHEETS, SHEET

DO NOT SCALE DRAWING

04 APRIL 2013

RRG

LA 11-0015

This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le without the Architect 's e x p r e s s w r i t t e n p e r m i s s i o n .

11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL

12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL

02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL

03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL

04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL

04.30.2013GENERAL REVISION1

RECORD DRAWING

07-11-2014

THESE RECORD DRAWINGS HAVE

BEEN PREPARED, IN PART, ON THE

BASIS OF INFORMATION COMPILED

AND FURNISHED BY OTHERS. THE

ARCHITECT CANNOT ASSURE ITS

ACCURACY AND THEREFORE

CANNOT BE RESPONSIBLE FOR ANY

ERRORS OR OMISSIONS WHICH

HAVE BEEN INCORPORATED INTO

THIS DOCUMENT AS A RESULT.

01 RECORD DRAWING SUBMITTAL 03.10.2014

LACKLAND AIR FORCE BASE, TEXAS

37th TRAINING WING

REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO

LACKLAND AFB, TX

Velocity Con-Cor, LLC.

10 9 8 7 6 5 4 3 2 1

F

E

D

C

B

A

10 9 8 7 6 5 4 2 1

A

B

C

D

E

F

G

APPROVALDATEDESCRIPTIONZONESYMBOL

DATE:

PROJECT NUMBER

DRAWING NUMBER

DATE

SCALE: AS NOTED

BASE CIVIL ENGINEER

APPROVED

CHIEF ENGINEERING FLIGHT (CEC)

RECOMMENDED

CHIEF CONTRACTS SECTION (CECC)

RECOMMENDED

CONSTRUCTABILITY REVIEW (CECC2)

USING AGENCY

FIRE CHIEF (CEFS)

DESIGN TEAM

ENGINEER/DESIGNER

DRAWN BY

AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE

REVISIONS

MPLS 11-014

IN SHEETS, SHEET

DO NOT SCALE DRAWING

04 APRIL 2013

RRG

LA 11-0015

This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le without the Architect 's e x p r e s s w r i t t e n p e r m i s s i o n .

11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL

12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL

02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL

03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL

04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL

04.30.2013GENERAL REVISION1

RECORD DRAWING

07-11-2014

THESE RECORD DRAWINGS HAVE

BEEN PREPARED, IN PART, ON THE

BASIS OF INFORMATION COMPILED

AND FURNISHED BY OTHERS. THE

ARCHITECT CANNOT ASSURE ITS

ACCURACY AND THEREFORE

CANNOT BE RESPONSIBLE FOR ANY

ERRORS OR OMISSIONS WHICH

HAVE BEEN INCORPORATED INTO

THIS DOCUMENT AS A RESULT.

01 RECORD DRAWING SUBMITTAL 03.10.2014

LACKLAND AIR FORCE BASE, TEXAS

37th TRAINING WING

REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO

LACKLAND AFB, TX

Velocity Con-Cor, LLC.

File details come from the government source that posted it. Updated .