This solicitation is for design-build renovation services for a controlled area at Joint Base San Antonio Lackland Air Force Base. The project budget is between $500,000 and $1,000,000, and Davis-Bacon wage rates apply. This acquisition is set aside for women-owned small businesses. Offerors must be certified through the SBA WOSB program and documents verifying eligibility must be submitted with the initial offer. The solicitation requires offerors to complete identification blocks, pricing, and certifications on the SF1442 form. A detailed proposal and all supporting documentation as specified in the instructions must also be submitted. The response deadline is not provided.
View the file
Other files for this federal contract opportunity
Show all 30
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
U P
UP
OFFICE 341
CLASSROOM 328-329
CLASSROOM 340
MECHANICAL RM ROOF BELOW
CLASSROOM 310CLASSROOM 309
MEN
ELEC.
JAN.
WOMEN
ELEV
CORRIDOR CLASSROOM 311
CLASSROOM 312 C
H
AS
E
STORAGE 314 C
H
AS
E
STAIR 3
STORE ROOM 315STORE ROOM 316
OFFICE 317OFFICE 318
CLASSROOM 319
CORRIDOR 302
STORAGE 320A
STORAGE 320
OFFICE 321OFFICE 323
OFFICE 322
STAIR 2
COMM. 303
STORAGE 327
STORAGE 326
CLASSROOM)
CLASSROOM 313
V I F
STORE ROOM 315STORE ROOM 316
SWING SPACE
OFFICE 316 OFFICE 315
(TYP.)
(TYP.)
(TYP.)(TYP.)
(TYP.)
(TYP.)
(TYP.)
(TYP.)
(TYP.)
(TYP.)
(TYP.) (TYP.)
(TYP.)
(TYP.)
(TYP.)
(TYP.)
(TYP.)
MEN
ELEC.
JAN.
WOMEN
ELEV
CORRIDOR
COMM.
(E)31/31 EA
RISER UP TO
(E)FAN
(E)16/16
(E)14/16
(E)16/8
(E)16/6
(E )6 "Ø H O T
AI
R
(E )8 "Ø C O
LD
A
IR
(E)
(E)22/16 EA
RISER FROM
SECOND
FLOOR
(E)6"Ø (E)6"Ø
(E)16/8
(E)
G
10 9 8 7 6 5 4 3 2 1
F
E
D
C
B
A
10 9 8 7 6 5 4 2 1
A
B
C
D
E
F
G
APPROVALDATEDESCRIPTIONZONESYMBOL
DATE:
PROJECT NUMBER
DRAWING NUMBER
DATE
SCALE: AS NOTED
BASE CIVIL ENGINEER
APPROVED
CHIEF ENGINEERING FLIGHT (CEC)
RECOMMENDED
CHIEF CONTRACTS SECTION (CECC)
RECOMMENDED
CONSTRUCTABILITY REVIEW (CECC2)
USING AGENCY
FIRE CHIEF (CEFS)
DESIGN TEAM
ENGINEER/DESIGNER
DRAWN BY
AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE
REVISIONS
MPLS 11-014
IN SHEETS, SHEET
DO NOT SCALE DRAWING
04 APRIL 2013
RRG
LA 11-0015
This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le wi thout the Archi tect 's e x p r e s s w r i t t e n p e r m i s s i o n .
11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL
12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL
02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL
03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL
04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL
04.30.2013GENERAL REVISION1
RECORD DRAWING
07-11-2014
THESE RECORD DRAWINGS HAVE
BEEN PREPARED, IN PART, ON THE
BASIS OF INFORMATION COMPILED
AND FURNISHED BY OTHERS. THE
ARCHITECT CANNOT ASSURE ITS
ACCURACY AND THEREFORE
CANNOT BE RESPONSIBLE FOR ANY
ERRORS OR OMISSIONS WHICH
HAVE BEEN INCORPORATED INTO
THIS DOCUMENT AS A RESULT.
01 RECORD DRAWING SUBMITTAL 03.10.2014
LACKLAND AIR FORCE BASE, TEXAS
37th TRAINING WING
REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO
LACKLAND AFB, TX
Velocity Con-Cor, LLC.
02 RECORD DRAWING SUBMITTAL 04.28.2014
03 RECORD DRAWING SUBMITTAL 05.23.2014
UP
OFFICE 341
CLASSROOM 328-329
CLASSROOM 340
MECHANICAL RM ROOF BELOW
CLASSROOM 310CLASSROOM 309
MEN
ELEC.
JAN.
WOMEN
ELEV
CORRIDOR CLASSROOM 311
CLASSROOM 312 C
H
AS
E
STORAGE 314 C
H
AS
E
STAIR 3
OFFICE 317OFFICE 318
CLASSROOM 319
CORRIDOR 302
SWING SPACE
OFFICE 321
SWING SPACE
OFFICE 323
SWING SPACE
OFFICE 322
SWING SPACE
(SWING SPACE
OFFICE 330
STAIR 2
COMM. 303
STORAGE 327
OFFICE 316 OFFICE 315
STORAGE 326
OFFICE 320
CLASSROOM)
CLASSROOM 313
V I F
(TYP.)
(TYP.)
(TYP.)
(TYP.)
(TYP.)
(TYP.)
(TYP.)
(TYP.)
(TYP.)
(TYP.)
(TYP.) (TYP.)
(TYP.)
H/205H/205H/205H/205
H/165
H/165
J/1525 (TYP.
FOR 2)
E/775 (TYP.
FOR 4)
J/1495 (TYP.
FOR 2)
E/760 (TYP.
FOR 4)
J/1495 (TYP.
FOR 2)
E/760 (TYP.
FOR 4)
E/780 (TYP.
FOR 4)
J/1535 (TYP.
FOR 2)
H/165H/165
J/1850 (TYP.
FOR 2)
F/950 (TYP.
FOR 4)
N/300C/300C/300N/300
N/300N/300
C/300C/300
H/165
(TYP.)
(TYP.) J/1850 (TYP.
FOR 2)
F/950 (TYP.
FOR 4)
HC
CC
FAN
MEN
ELEC.
JAN.
WOMEN
ELEV
CORRIDOR
COMM.
(E )6 "Ø H O T
AI
R
(E )8 "Ø C O
LD
A
IR
(E)31/31 EA
RISER UP TO
EF-1
(E)14/16
(E)16/6
(E)22/16 EA
RISER FROM
SECOND
FLOOR
(E)6"Ø (E)6"Ø
(E)16/8
(E)16/16
POC
P/420
B/260
PROVIDE
PLASTER
FRAME
12/6
POC
B/165
PROVIDE
PLASTER
FRAME 12/6
POC
N/280
(E)
POC
12/6
G
10 9 8 7 6 5 4 3 2 1
F
E
D
C
B
A
10 9 8 7 6 5 4 2 1
A
B
C
D
E
F
G
APPROVALDATEDESCRIPTIONZONESYMBOL
DATE:
PROJECT NUMBER
DRAWING NUMBER
DATE
SCALE: AS NOTED
BASE CIVIL ENGINEER
APPROVED
CHIEF ENGINEERING FLIGHT (CEC)
RECOMMENDED
CHIEF CONTRACTS SECTION (CECC)
RECOMMENDED
CONSTRUCTABILITY REVIEW (CECC2)
USING AGENCY
FIRE CHIEF (CEFS)
DESIGN TEAM
ENGINEER/DESIGNER
DRAWN BY
AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE
REVISIONS
MPLS 11-014
IN SHEETS, SHEET
DO NOT SCALE DRAWING
04 APRIL 2013
RRG
LA 11-0015
This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le without the Architect 's e x p r e s s w r i t t e n p e r m i s s i o n .
11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL
12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL
02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL
03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL
04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL
04.30.2013GENERAL REVISION1
RECORD DRAWING
07-11-2014
THESE RECORD DRAWINGS HAVE
BEEN PREPARED, IN PART, ON THE
BASIS OF INFORMATION COMPILED
AND FURNISHED BY OTHERS. THE
ARCHITECT CANNOT ASSURE ITS
ACCURACY AND THEREFORE
CANNOT BE RESPONSIBLE FOR ANY
ERRORS OR OMISSIONS WHICH
HAVE BEEN INCORPORATED INTO
THIS DOCUMENT AS A RESULT.
01 RECORD DRAWING SUBMITTAL 03.10.2014
LACKLAND AIR FORCE BASE, TEXAS
37th TRAINING WING
REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO
LACKLAND AFB, TX
Velocity Con-Cor, LLC.
HWP-2 HWP-1
H C
C C
FAN
HWP-2 HWP-1
HWP-2 HWP-1
G
10 9 8 7 6 5 4 3 2 1
F
E
D
C
B
A
10 9 8 7 6 5 4 2 1
A
B
C
D
E
F
G
APPROVALDATEDESCRIPTIONZONESYMBOL
DATE:
PROJECT NUMBER
DRAWING NUMBER
DATE
SCALE: AS NOTED
BASE CIVIL ENGINEER
APPROVED
CHIEF ENGINEERING FLIGHT (CEC)
RECOMMENDED
CHIEF CONTRACTS SECTION (CECC)
RECOMMENDED
CONSTRUCTABILITY REVIEW (CECC2)
USING AGENCY
FIRE CHIEF (CEFS)
DESIGN TEAM
ENGINEER/DESIGNER
DRAWN BY
AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE
REVISIONS
MPLS 11-014
IN SHEETS, SHEET
DO NOT SCALE DRAWING
04 APRIL 2013
RRG
LA 11-0015
This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le without the Architect 's e x p r e s s w r i t t e n p e r m i s s i o n .
11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL
12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL
02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL
03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL
04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL
04.30.2013GENERAL REVISION1
RECORD DRAWING
07-11-2014
THESE RECORD DRAWINGS HAVE
BEEN PREPARED, IN PART, ON THE
BASIS OF INFORMATION COMPILED
AND FURNISHED BY OTHERS. THE
ARCHITECT CANNOT ASSURE ITS
ACCURACY AND THEREFORE
CANNOT BE RESPONSIBLE FOR ANY
ERRORS OR OMISSIONS WHICH
HAVE BEEN INCORPORATED INTO
THIS DOCUMENT AS A RESULT.
01 RECORD DRAWING SUBMITTAL 03.10.2014
LACKLAND AIR FORCE BASE, TEXAS
37th TRAINING WING
REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO
LACKLAND AFB, TX
Velocity Con-Cor, LLC.
MARK CFM
RANGE
NECK
SIZE THROWDAMPER LOCATION REMARKS
TMS, TYPE 3 FRAME
24"X24" MODULE
LAY-IN
CEILINGYES4W6"Ø5-160A
EF-1 3670 1.0" BELT 1076 200#REST
ROOMS
1.5/460/3 OCCUPANCYROOF
EXHAUST
UNIT SHALL BE U.L. LISTED, A.M.C.A. CERTIFIED AND
FURNISHED WITH BACKDRAFT DAMPER, ALUMINUM
BIRDSCREEN AND DISCONNECT SWITCH.
INSTALL FAN AT EXISTING ROOF CURB. PROVIDE CURB
ADAPTER AS REQUIRED.
EQUIVALENT MANUFACTURERS: GREENHECK, ACME,
BREIDERT AND PENN VENTILATOR
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
B
C
D
E
F
G
H
J
K
L
M
N
P
4W
4W
4W
4W
4W
4W
4W
YES
YES
(TITUS MODEL #)
SURFACE
SURFACE
SURFACE
WALL
WALL
WALL
165-280
285-450
455-685
690-860
865-985
165-280
375-1885
250-440
550-875
5-200
205-350
355-650
5-160
8"Ø
10"Ø
12"Ø
14"Ø
15"Ø
6"Ø
8"Ø
24"X24"
18"X6"
24"X8"
12"X6"
12"X12"
16"X16"
TMS, TYPE 3 FRAME
24"X24" MODULE
TMS, TYPE 3 FRAME
24"X24" MODULE
TMS, TYPE 3 FRAME
24"X24" MODULE
TMS, TYPE 3 FRAME
24"X24" MODULE
TMS, TYPE 3 FRAME
24"X24" MODULE
TMS, TYPE 3 FRAME
12"X12" MODULE
TMS, TYPE 1 FRAME
12"X12" MODULE
350RS, TYPE 3
BORDER;
24"X24"MODULE
3OORS
350RS
350RS
350RS
NOTES:
NOT ALL MARKS MAY BE USED.
ALL AIR DEVICES TO HAVE OFF WHITE FINISH.
PROVIDE 'TR' SQ TO ROU;ND ADAPTER REDUCER AS REQUIRED.
EQUIVALENT MANUFACTURERS: METAL-AIRE, ANEMOSTAT, KRUEGER, AND PRICE
ACE-195C8B
LAY-IN
CEILING
LAY-IN
CEILING
LAY-IN
CEILING
LAY-IN
CEILING
LAY-IN
CEILING
LAY-IN
CEILING
WALL 3OORS
Q - NO WALL440-560 18"X10" 350RS
G
10 9 8 7 6 5 4 3 2 1
F
E
D
C
B
A
10 9 8 7 6 5 4 2 1
A
B
C
D
E
F
G
APPROVALDATEDESCRIPTIONZONESYMBOL
DATE:
PROJECT NUMBER
DRAWING NUMBER
DATE
SCALE: AS NOTED
BASE CIVIL ENGINEER
APPROVED
CHIEF ENGINEERING FLIGHT (CEC)
RECOMMENDED
CHIEF CONTRACTS SECTION (CECC)
RECOMMENDED
CONSTRUCTABILITY REVIEW (CECC2)
USING AGENCY
FIRE CHIEF (CEFS)
DESIGN TEAM
ENGINEER/DESIGNER
DRAWN BY
AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE
REVISIONS
MPLS 11-014
IN SHEETS, SHEET
DO NOT SCALE DRAWING
04 APRIL 2013
RRG
LA 11-0015
This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le without the Architect 's e x p r e s s w r i t t e n p e r m i s s i o n .
11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL
12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL
02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL
03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL
04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL
04.30.2013GENERAL REVISION1
RECORD DRAWING
07-11-2014
THESE RECORD DRAWINGS HAVE
BEEN PREPARED, IN PART, ON THE
BASIS OF INFORMATION COMPILED
AND FURNISHED BY OTHERS. THE
ARCHITECT CANNOT ASSURE ITS
ACCURACY AND THEREFORE
CANNOT BE RESPONSIBLE FOR ANY
ERRORS OR OMISSIONS WHICH
HAVE BEEN INCORPORATED INTO
THIS DOCUMENT AS A RESULT.
01 RECORD DRAWING SUBMITTAL 03.10.2014
LACKLAND AIR FORCE BASE, TEXAS
37th TRAINING WING
REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO
LACKLAND AFB, TX
Velocity Con-Cor, LLC.
(E)EXTERNALLY WRAP
SHEET METAL SUPPLY
DUCT
EXISTING AIR DEVICE
SHALL BE REMOVED
AND REPLACED WITH
NEW
POC
EXISTING ROUND DUCT
TO REMAIN FOR
CONNECTION TO NEW
DIFFUSER. PROVIDE
DUCT TO RECONNECT TO
NEW AIR DEVICE AS
REQUIRED.
RESIL.
GROMMET
MOUNTED IN
SHT. MTL.
PANEL
DRIP
EDGE
2" X 2" WD.
BLOCKING BOLTED
TO MTL. CURB WITH
3/8" BOLTS AT 6"
O.C.
PREFABRICATED
MTL. CURB
AND CANT
POULTRY
NETTING FILL
BOX ABOVE
W/LOOSE
INSUL.
MTL.
DECK
TOP CHORD
OF BAR
JOIST
2-1/2" X 2-1/2" X 1/4"
STL. ANGLE HEADER
WELDED TO BAR
JOISTS
WD. BLOCKING
ANCHORED BY 1/2"
BOLTS @ 12" O.C.
CUT METAL DECK FOR
NEW PIPE
PENETRATION
RIGID
INSUL.
FLASHING
INTO
ROOFING
CONT.
CLEAT
CURB
FLASHING
CADMIUM PLATED
SCREWS
W/NEOPRENE
WASHERS AT 4" O.C.
SEE MECH./ELEC.
FOR PIPE SIZES
SHEET
METAL
WEATHER
HOOD
G
10 9 8 7 6 5 4 3 2 1
F
E
D
C
B
A
10 9 8 7 6 5 4 2 1
A
B
C
D
E
F
G
APPROVALDATEDESCRIPTIONZONESYMBOL
DATE:
PROJECT NUMBER
DRAWING NUMBER
DATE
SCALE: AS NOTED
BASE CIVIL ENGINEER
APPROVED
CHIEF ENGINEERING FLIGHT (CEC)
RECOMMENDED
CHIEF CONTRACTS SECTION (CECC)
RECOMMENDED
CONSTRUCTABILITY REVIEW (CECC2)
USING AGENCY
FIRE CHIEF (CEFS)
DESIGN TEAM
ENGINEER/DESIGNER
DRAWN BY
AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE
REVISIONS
MPLS 11-014
IN SHEETS, SHEET
DO NOT SCALE DRAWING
04 APRIL 2013
RRG
LA 11-0015
This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le without the Architect 's e x p r e s s w r i t t e n p e r m i s s i o n .
11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL
12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL
02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL
03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL
04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL
04.30.2013GENERAL REVISION1
RECORD DRAWING
07-11-2014
THESE RECORD DRAWINGS HAVE
BEEN PREPARED, IN PART, ON THE
BASIS OF INFORMATION COMPILED
AND FURNISHED BY OTHERS. THE
ARCHITECT CANNOT ASSURE ITS
ACCURACY AND THEREFORE
CANNOT BE RESPONSIBLE FOR ANY
ERRORS OR OMISSIONS WHICH
HAVE BEEN INCORPORATED INTO
THIS DOCUMENT AS A RESULT.
01 RECORD DRAWING SUBMITTAL 03.10.2014
LACKLAND AIR FORCE BASE, TEXAS
37th TRAINING WING
REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO
LACKLAND AFB, TX
Velocity Con-Cor, LLC.
OA
RA
SF-C
SF-S
SDR-1
SF VFD
LT-A
PFILT-S
SUPPLY
RETURN C A
B
CLG-O
C
C CD
SUPPLY
RETURNCA
B
RH-O
H
C
CD-T
DAPHI-A
L H
CD-P
LH
LOCATED 2/3 DOWN THE
LONGEST DUCT RUN
HD
HD-T
HD-P
LH
LOCATED 2/3 DOWN THE
LONGEST DUCT RUN
NC
OAD-O
SF-O
AHU 3 AND 4
DUAL DUCT UNITS
SEQUENCE OF OPERATION
SUPPLY FAN CONTROL: THE VARIABLE SPEED SUPPLY FAN WILL BE STARTED BASED ON OCCUPANCY SCHEDULE. WHEN THE SUPPLY FAN STATUS INDICATES THE FAN STARTED, THE CONTROL SEQUENCE WILL BE ENABLED. THE SUPPLY FAN WILL MODULATE TO MAINTAIN THE DISCHARGE STATIC PRESSURE, AS DETERMINED FROM THE MINIMUM OF THE HOT DECK AND COLD DECK DUCT STATIC PRESSURE SENSORS, AT
SETPOINT. UPON A LOSS OF AIRFLOW, THE SUPPLY FAN WILL AUTOMATICALLY RESTART.
OA CONTROL: THE OA DAMPER WILL OPEN WHEN AIR UNIT IS ENABLED UNDER OCCUPIED CONDITIONS AND
WILL CLOSE WHEN AREA IS UNOCCUPIED.
TEMPERATURE CONTROL: THE UNIT WILL CONTROL TO MAINTAIN A CONSTANT COLD DECK AND HOT DECK
DISCHARGE AIR TEMPERATURE.
OCCUPIED MODE: THE OCCUPANCY MODE WILL BE CONTROLLED VIA A NETWORK INPUT. THE OCCUPANCY
MODE CAN ALSO BE OVERRIDDEN BY A NETWORK INPUT.
UNOCCUPIED MODE: THE UNIT WILL REMAIN OFF DURING UNOCCUPIED PERIODS.
COLD DECK: THE COOLING COIL WILL MODULATE TO MAINTAIN THE COLD DECK TEMPERATURE SETPOINT.
WHEN THE UNIT IS SHUTDOWN, THE COOLING COIL WILL BE COMMANDED TO A PRESET POSITION SHOULD THE OUTDOOR AIR TEMPERATURE FALL BELOW THE LOW OUTDOOR AIR TEMPERATURE SETPOINT. UPON A
LOSS OF AIRFLOW, THE COOLING COIL WILL BE OFF.
HOT DECK: THE HOT DECK COIL WILL MODULATE TO MAINTAIN THE HOT DECK TEMPERATURE SETPOINT.
WHEN THE UNIT IS SHUTDOWN, THE HOT DECK COIL WILL BE COMMANDED TO A PRESET POSITION SHOULD THE OUTDOOR AIR TEMPERATURE FALL BELOW THE LOW OUTDOOR AIR TEMPERATURE SETPOINT. UPON A
LOSS OF AIRFLOW, THE HOT DECK COIL WILL REMAIN IN CONTROL.
PHWP2-C
PHWP2-S
PHWP1-C
PHWP1-S
HWS
HWR
OA-T
LOCATED IN THE SHADE ON THE
NORTH SIDE OF THE BUILDING
Boiler 1
BLR2LW-T
PHWR-T
NC C
MIX-O
NO
BLR1LW-T
PHWP2
Boiler 2
BLR1ISOV-S
BLR1ISOV-C
BLR2ISOV-C
BLR2ISOV-S
PHWP1
BLR1-EN
BLR1SP-O
BLR1-A
BLR1-S
BOILER 1 CONTROL
CABINET
BLR2-EN
BLR2SP-O
BLR2-A
BLR2-S
BOILER 2 CONTROL
CABINET
PHWP1 STARTER
PHWP2 STARTER
PHWS-T
HOT WATER SYSTEM
SEQUENCE OF OPERATION:
SYSTEM ENABLE: THE HEATING SYSTEM WILL AUTOMATICALLY
START WHEN THE SYSTEM ENABLE IS "ON". WHEN THE SYSTEM
ENABLE IS "OFF", THE HEATING SYSTEM WILL BE DISABLED.
BOILER CONTROL: THIS SYSTEM CONSISTS OF TWO BOILERS.
THE BURNERS SHALL BE CONTROLLED VIA THEIR OWN
INTERNAL CONTROLS. THE OUTDOOR AIR TEMPERATURE
SHALL DETERMINE THE NUMBER OF BOILERS RUNNING. A 3-
WAY MIXING VALVE SHALL MODULATE TO MAINTAIN SUPPLY
WATER TEMPERATURE DELIVERED TO THE BUILDING TO
SETPOINT AS RESET BY THE OUTDOOR AIR TEMPERATURE. THE
BOILER SETPOINT WILL BE CONTROLLED REMOTELY VIA THE
FMS. WHEN AN ADDITIONAL BOILER IS REQUIRED, THE BOILER
WITH THE LOWEST RUNTIME TOTAL SHALL BE ENABLED TO RUN.
THE BOILER ISOLATION VALVE WILL BE COMMANDED OPEN
PRIOR TO STARTING THE PUMP AND KEPT OPEN LONG ENOUGH
FOR THE PUMP TO COAST DOWN. IF THE STATUS OF THE
BOILER ISOLATION VALVE FAILS TO MATCH THE COMMAND, AN
ALARM WILL BE GENERATED AND THE NEXT BOILER IN
SEQUENCE WILL BE ENABLED.
HOT WATER PUMP CONTROL: WHEN ENABLED, A PUMP FOR
EACH BOILER WILL BE STARTED. AFTER THE BOILER IS
COMMANDED OFF, THE PUMP WILL CONTINUE TO RUN FOR A
SHORT TIME TO DISSIPATE THE HEAT. IF THE PUMP STATUS
DOES NOT MATCH THE COMMAND, AN ALARM WILL BE
GENERATED AND THE PUMP WILL BE STOPPED. UPON LOSS OF
STATUS, THE PUMP WILL RESTART AFTER THE SYSTEM RESET
IS ACTIVATED.
ADDITIONAL POINTS MONITORED BY THE FMS:
BOILER n STATUS (BLRn-S) BOILER n ALARM (BLRn-A) BOILER n LEAVING WATER TEMPERATURE (BLRnLW-T)
PRIMARY HW RETURN TEMPERATURE (PHWR-T)
OUTDOOR AIR TEMPERATURE (OA-T)
HWR
HWS
G
10 9 8 7 6 5 4 3 2 1
F
E
D
C
B
A
10 9 8 7 6 5 4 2 1
A
B
C
D
E
F
G
APPROVALDATEDESCRIPTIONZONESYMBOL
DATE:
PROJECT NUMBER
DRAWING NUMBER
DATE
SCALE: AS NOTED
BASE CIVIL ENGINEER
APPROVED
CHIEF ENGINEERING FLIGHT (CEC)
RECOMMENDED
CHIEF CONTRACTS SECTION (CECC)
RECOMMENDED
CONSTRUCTABILITY REVIEW (CECC2)
USING AGENCY
FIRE CHIEF (CEFS)
DESIGN TEAM
ENGINEER/DESIGNER
DRAWN BY
AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE
REVISIONS
MPLS 11-014
IN SHEETS, SHEET
DO NOT SCALE DRAWING
04 APRIL 2013
RRG
LA 11-0015
This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le without the Architect 's e x p r e s s w r i t t e n p e r m i s s i o n .
11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL
12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL
02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL
03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL
04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL
04.30.2013GENERAL REVISION1
RECORD DRAWING
07-11-2014
THESE RECORD DRAWINGS HAVE
BEEN PREPARED, IN PART, ON THE
BASIS OF INFORMATION COMPILED
AND FURNISHED BY OTHERS. THE
ARCHITECT CANNOT ASSURE ITS
ACCURACY AND THEREFORE
CANNOT BE RESPONSIBLE FOR ANY
ERRORS OR OMISSIONS WHICH
HAVE BEEN INCORPORATED INTO
THIS DOCUMENT AS A RESULT.
01 RECORD DRAWING SUBMITTAL 03.10.2014
LACKLAND AIR FORCE BASE, TEXAS
37th TRAINING WING
REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO
LACKLAND AFB, TX
Velocity Con-Cor, LLC.
UGE
UGT
ELECTRICAL SYMBOLS AND ABBREVIATIONS
ACS
I
PP
WAP
CAM
REX
ES
PB
EPB
DB
IC
DS
CCTV
PJ
I
SP
SP
T
DH
H
FF
D
J
R
C
J
F
DB
LC
FS
PS
FS
TS
TS
HD
GB
SD
DSD
A
V
AV
ML
MD
DC
CR
ANN
FAEX
FACP
SEC
ISC
AMP
G
10 9 8 7 6 5 4 3 2 1
F
E
D
C
B
A
10 9 8 7 6 5 4 2 1
A
B
C
D
E
F
G
APPROVALDATEDESCRIPTIONZONESYMBOL
DATE:
PROJECT NUMBER
DRAWING NUMBER
DATE
SCALE: AS NOTED
BASE CIVIL ENGINEER
APPROVED
CHIEF ENGINEERING FLIGHT (CEC)
RECOMMENDED
CHIEF CONTRACTS SECTION (CECC)
RECOMMENDED
CONSTRUCTABILITY REVIEW (CECC2)
USING AGENCY
FIRE CHIEF (CEFS)
DESIGN TEAM
ENGINEER/DESIGNER
DRAWN BY
AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE
REVISIONS
MPLS 11-014
IN SHEETS, SHEET
DO NOT SCALE DRAWING
04 APRIL 2013
RRG
LA 11-0015
This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le wi thout the Archi tect 's e x p r e s s w r i t t e n p e r m i s s i o n .
11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL
12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL
02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL
03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL
04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL
04.30.2013GENERAL REVISION1
RECORD DRAWING
07-11-2014
THESE RECORD DRAWINGS HAVE
BEEN PREPARED, IN PART, ON THE
BASIS OF INFORMATION COMPILED
AND FURNISHED BY OTHERS. THE
ARCHITECT CANNOT ASSURE ITS
ACCURACY AND THEREFORE
CANNOT BE RESPONSIBLE FOR ANY
ERRORS OR OMISSIONS WHICH
HAVE BEEN INCORPORATED INTO
THIS DOCUMENT AS A RESULT.
01 RECORD DRAWING SUBMITTAL 03.10.2014
LACKLAND AIR FORCE BASE, TEXAS
37th TRAINING WING
REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO
LACKLAND AFB, TX
Velocity Con-Cor, LLC.
UP
CLASSROOM 310CLASSROOM 309
MEN
ELEC.
JAN.
WOMEN
ELEV
CORRIDOR CLASSROOM 311
CLASSROOM 312 C
H
AS
E
STORAGE 314 C
H
AS
E
STAIR 3
STORE ROOM 315STORE ROOM 316
OFFICE 317OFFICE 318
CLASSROOM 319
CORRIDOR 302
STORAGE 320A
STORAGE 320
OFFICE 321OFFICE 323
OFFICE 322
STAIR 2
COMM. 303
STORAGE 327
STORAGE 326
CLASSROOM)
CLASSROOM 313
V I F
STORE ROOM 315STORE ROOM 316
SWING SPACE
OFFICE 316 OFFICE 315
G
10 9 8 7 6 5 4 3 2 1
F
E
D
C
B
A
10 9 8 7 6 5 4 2 1
A
B
C
D
E
F
G
APPROVALDATEDESCRIPTIONZONESYMBOL
DATE:
PROJECT NUMBER
DRAWING NUMBER
DATE
SCALE: AS NOTED
BASE CIVIL ENGINEER
APPROVED
CHIEF ENGINEERING FLIGHT (CEC)
RECOMMENDED
CHIEF CONTRACTS SECTION (CECC)
RECOMMENDED
CONSTRUCTABILITY REVIEW (CECC2)
USING AGENCY
FIRE CHIEF (CEFS)
DESIGN TEAM
ENGINEER/DESIGNER
DRAWN BY
AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE
REVISIONS
MPLS 11-014
IN SHEETS, SHEET
DO NOT SCALE DRAWING
04 APRIL 2013
RRG
LA 11-0015
This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le without the Architect 's e x p r e s s w r i t t e n p e r m i s s i o n .
11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL
12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL
02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL
03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL
04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL
04.30.2013GENERAL REVISION1
RECORD DRAWING
07-11-2014
THESE RECORD DRAWINGS HAVE
BEEN PREPARED, IN PART, ON THE
BASIS OF INFORMATION COMPILED
AND FURNISHED BY OTHERS. THE
ARCHITECT CANNOT ASSURE ITS
ACCURACY AND THEREFORE
CANNOT BE RESPONSIBLE FOR ANY
ERRORS OR OMISSIONS WHICH
HAVE BEEN INCORPORATED INTO
THIS DOCUMENT AS A RESULT.
01 RECORD DRAWING SUBMITTAL 03.10.2014
LACKLAND AIR FORCE BASE, TEXAS
37th TRAINING WING
REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO
LACKLAND AFB, TX
Velocity Con-Cor, LLC.
UP
CLASSROOM 310CLASSROOM 309
MEN
ELEC.
JAN.
WOMEN
ELEV
CORRIDOR CLASSROOM 311
CLASSROOM 312 C
H
AS
E
STORAGE 314 C
H
AS
E
STAIR 3
STORE ROOM 315STORE ROOM 316
OFFICE 317OFFICE 318
CLASSROOM 319
CORRIDOR 302
STORAGE 320A
STORAGE 320
OFFICE 321OFFICE 323
OFFICE 322
STAIR 2
COMM. 303
STORAGE 327
STORAGE 326
CLASSROOM)
CLASSROOM 313
V I F
STORE ROOM 315STORE ROOM 316
SWING SPACE
OFFICE 316 OFFICE 315
G
10 9 8 7 6 5 4 3 2 1
F
E
D
C
B
A
10 9 8 7 6 5 4 2 1
A
B
C
D
E
F
G
APPROVALDATEDESCRIPTIONZONESYMBOL
DATE:
PROJECT NUMBER
DRAWING NUMBER
DATE
SCALE: AS NOTED
BASE CIVIL ENGINEER
APPROVED
CHIEF ENGINEERING FLIGHT (CEC)
RECOMMENDED
CHIEF CONTRACTS SECTION (CECC)
RECOMMENDED
CONSTRUCTABILITY REVIEW (CECC2)
USING AGENCY
FIRE CHIEF (CEFS)
DESIGN TEAM
ENGINEER/DESIGNER
DRAWN BY
AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE
REVISIONS
MPLS 11-014
IN SHEETS, SHEET
DO NOT SCALE DRAWING
04 APRIL 2013
RRG
LA 11-0015
This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le wi thout the Archi tect 's e x p r e s s w r i t t e n p e r m i s s i o n .
11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL
12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL
02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL
03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL
04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL
04.30.2013GENERAL REVISION1
RECORD DRAWING
07-11-2014
THESE RECORD DRAWINGS HAVE
BEEN PREPARED, IN PART, ON THE
BASIS OF INFORMATION COMPILED
AND FURNISHED BY OTHERS. THE
ARCHITECT CANNOT ASSURE ITS
ACCURACY AND THEREFORE
CANNOT BE RESPONSIBLE FOR ANY
ERRORS OR OMISSIONS WHICH
HAVE BEEN INCORPORATED INTO
THIS DOCUMENT AS A RESULT.
01 RECORD DRAWING SUBMITTAL 03.10.2014
LACKLAND AIR FORCE BASE, TEXAS
37th TRAINING WING
REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO
LACKLAND AFB, TX
Velocity Con-Cor, LLC.
UP
CLASSROOM 310CLASSROOM 309
MEN
ELEC.
JAN.
WOMEN
ELEV
CORRIDOR CLASSROOM 311
CLASSROOM 312 C
H
AS
E
STORAGE 314 C
H
AS
E
STAIR 3
STORE ROOM 315STORE ROOM 316
OFFICE 317OFFICE 318
CLASSROOM 319
CORRIDOR 302
STORAGE 320A
STORAGE 320
OFFICE 321OFFICE 323
OFFICE 322
STAIR 2
COMM. 303
STORAGE 327
STORAGE 326
CLASSROOM)
CLASSROOM 313
V I F
STORE ROOM 315STORE ROOM 316
SWING SPACE
OFFICE 316 OFFICE 315
G
10 9 8 7 6 5 4 3 2 1
F
E
D
C
B
A
10 9 8 7 6 5 4 2 1
A
B
C
D
E
F
G
APPROVALDATEDESCRIPTIONZONESYMBOL
DATE:
PROJECT NUMBER
DRAWING NUMBER
DATE
SCALE: AS NOTED
BASE CIVIL ENGINEER
APPROVED
CHIEF ENGINEERING FLIGHT (CEC)
RECOMMENDED
CHIEF CONTRACTS SECTION (CECC)
RECOMMENDED
CONSTRUCTABILITY REVIEW (CECC2)
USING AGENCY
FIRE CHIEF (CEFS)
DESIGN TEAM
ENGINEER/DESIGNER
DRAWN BY
AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE
REVISIONS
MPLS 11-014
IN SHEETS, SHEET
DO NOT SCALE DRAWING
04 APRIL 2013
RRG
LA 11-0015
This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le wi thout the Archi tect 's e x p r e s s w r i t t e n p e r m i s s i o n .
11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL
12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL
02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL
03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL
04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL
04.30.2013GENERAL REVISION1
RECORD DRAWING
07-11-2014
THESE RECORD DRAWINGS HAVE
BEEN PREPARED, IN PART, ON THE
BASIS OF INFORMATION COMPILED
AND FURNISHED BY OTHERS. THE
ARCHITECT CANNOT ASSURE ITS
ACCURACY AND THEREFORE
CANNOT BE RESPONSIBLE FOR ANY
ERRORS OR OMISSIONS WHICH
HAVE BEEN INCORPORATED INTO
THIS DOCUMENT AS A RESULT.
01 RECORD DRAWING SUBMITTAL 03.10.2014
LACKLAND AIR FORCE BASE, TEXAS
37th TRAINING WING
REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO
LACKLAND AFB, TX
Velocity Con-Cor, LLC.
UP
CLASSROOM 310CLASSROOM 309
MEN
ELEC.
JAN.
WOMEN
ELEV
CORRIDOR CLASSROOM 311
CLASSROOM 312 C
H
AS
E
STORAGE 314 C
H
AS
E
STAIR 3
OFFICE 317OFFICE 318
CLASSROOM 319
CORRIDOR 302
SWING SPACE
OFFICE 321
SWING SPACE
OFFICE 323
SWING SPACE
OFFICE 322
SWING SPACE
(SWING SPACE
STAIR 2
COMM. 303
STORAGE 327
OFFICE 316 OFFICE 315
STORAGE 326
OFFICE 320
CLASSROOM)
CLASSROOM 313
V I F
72/20
XCR72
O
SERA
KRUG
TABLE
O
OO
6910-18D-29
G
10 9 8 7 6 5 4 3 2 1
F
E
D
C
B
A
10 9 8 7 6 5 4 2 1
A
B
C
D
E
F
G
APPROVALDATEDESCRIPTIONZONESYMBOL
DATE:
PROJECT NUMBER
DRAWING NUMBER
DATE
SCALE: AS NOTED
BASE CIVIL ENGINEER
APPROVED
CHIEF ENGINEERING FLIGHT (CEC)
RECOMMENDED
CHIEF CONTRACTS SECTION (CECC)
RECOMMENDED
CONSTRUCTABILITY REVIEW (CECC2)
USING AGENCY
FIRE CHIEF (CEFS)
DESIGN TEAM
ENGINEER/DESIGNER
DRAWN BY
AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE
REVISIONS
MPLS 11-014
IN SHEETS, SHEET
DO NOT SCALE DRAWING
04 APRIL 2013
RRG
LA 11-0015
This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le without the Architect 's e x p r e s s w r i t t e n p e r m i s s i o n .
11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL
12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL
02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL
03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL
04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL
04.30.2013GENERAL REVISION1
RECORD DRAWING
07-11-2014
THESE RECORD DRAWINGS HAVE
BEEN PREPARED, IN PART, ON THE
BASIS OF INFORMATION COMPILED
AND FURNISHED BY OTHERS. THE
ARCHITECT CANNOT ASSURE ITS
ACCURACY AND THEREFORE
CANNOT BE RESPONSIBLE FOR ANY
ERRORS OR OMISSIONS WHICH
HAVE BEEN INCORPORATED INTO
THIS DOCUMENT AS A RESULT.
01 RECORD DRAWING SUBMITTAL 03.10.2014
LACKLAND AIR FORCE BASE, TEXAS
37th TRAINING WING
REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO
LACKLAND AFB, TX
Velocity Con-Cor, LLC.
UP
CLASSROOM 310CLASSROOM 309
MEN
ELEC.
JAN.
WOMEN
ELEV
CORRIDOR CLASSROOM 311
CLASSROOM 312 C
H
AS
E
STORAGE 314 C
H
AS
E
STAIR 3
OFFICE 317OFFICE 318
CLASSROOM 319
CORRIDOR 302
SWING SPACE
OFFICE 321
SWING SPACE
OFFICE 323
SWING SPACE
OFFICE 322
SWING SPACE
(SWING SPACE
STAIR 2
COMM. 303
STORAGE 327
OFFICE 316 OFFICE 315
STORAGE 326
OFFICE 320
CLASSROOM)
CLASSROOM 313
V I F
72/20
XCR72
O
/7
5/
L
42/87/66L
/7
5/
L
SERA
KRUG
TABLE
O
/7
5/
L
/7
5/
L
OO
6910-18D-29
G
10 9 8 7 6 5 4 3 2 1
F
E
D
C
B
A
10 9 8 7 6 5 4 2 1
A
B
C
D
E
F
G
APPROVALDATEDESCRIPTIONZONESYMBOL
DATE:
PROJECT NUMBER
DRAWING NUMBER
DATE
SCALE: AS NOTED
BASE CIVIL ENGINEER
APPROVED
CHIEF ENGINEERING FLIGHT (CEC)
RECOMMENDED
CHIEF CONTRACTS SECTION (CECC)
RECOMMENDED
CONSTRUCTABILITY REVIEW (CECC2)
USING AGENCY
FIRE CHIEF (CEFS)
DESIGN TEAM
ENGINEER/DESIGNER
DRAWN BY
AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE
REVISIONS
MPLS 11-014
IN SHEETS, SHEET
DO NOT SCALE DRAWING
04 APRIL 2013
RRG
LA 11-0015
This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le without the Architect 's e x p r e s s w r i t t e n p e r m i s s i o n .
11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL
12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL
02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL
03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL
04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL
04.30.2013GENERAL REVISION1
RECORD DRAWING
07-11-2014
THESE RECORD DRAWINGS HAVE
BEEN PREPARED, IN PART, ON THE
BASIS OF INFORMATION COMPILED
AND FURNISHED BY OTHERS. THE
ARCHITECT CANNOT ASSURE ITS
ACCURACY AND THEREFORE
CANNOT BE RESPONSIBLE FOR ANY
ERRORS OR OMISSIONS WHICH
HAVE BEEN INCORPORATED INTO
THIS DOCUMENT AS A RESULT.
01 RECORD DRAWING SUBMITTAL 03.10.2014
LACKLAND AIR FORCE BASE, TEXAS
37th TRAINING WING
REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO
LACKLAND AFB, TX
Velocity Con-Cor, LLC.
UP
CLASSROOM 310CLASSROOM 309
MEN
ELEC.
JAN.
WOMEN
ELEV
CORRIDOR CLASSROOM 311
CLASSROOM 312 C
H
AS
E
STORAGE 314 C
H
AS
E
STAIR 3
OFFICE 317OFFICE 318
CLASSROOM 319
CORRIDOR 302
SWING SPACE
OFFICE 321
SWING SPACE
OFFICE 323
SWING SPACE
OFFICE 322
SWING SPACE
(SWING SPACE
STAIR 2
COMM. 303
STORAGE 327
OFFICE 316 OFFICE 315
STORAGE 326
OFFICE 320
CLASSROOM)
CLASSROOM 313
V I F
72/20
XCR72
O
/7
5/
L
42/87/66L
/7
5/
L
SERA
KRUG
TABLE
O
/7
5/
L
/7
5/
L
OO
6910-18D-29
G
10 9 8 7 6 5 4 3 2 1
F
E
D
C
B
A
10 9 8 7 6 5 4 2 1
A
B
C
D
E
F
G
APPROVALDATEDESCRIPTIONZONESYMBOL
DATE:
PROJECT NUMBER
DRAWING NUMBER
DATE
SCALE: AS NOTED
BASE CIVIL ENGINEER
APPROVED
CHIEF ENGINEERING FLIGHT (CEC)
RECOMMENDED
CHIEF CONTRACTS SECTION (CECC)
RECOMMENDED
CONSTRUCTABILITY REVIEW (CECC2)
USING AGENCY
FIRE CHIEF (CEFS)
DESIGN TEAM
ENGINEER/DESIGNER
DRAWN BY
AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE
REVISIONS
MPLS 11-014
IN SHEETS, SHEET
DO NOT SCALE DRAWING
04 APRIL 2013
RRG
LA 11-0015
This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le without the Architect 's e x p r e s s w r i t t e n p e r m i s s i o n .
11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL
12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL
02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL
03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL
04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL
04.30.2013GENERAL REVISION1
RECORD DRAWING
07-11-2014
THESE RECORD DRAWINGS HAVE
BEEN PREPARED, IN PART, ON THE
BASIS OF INFORMATION COMPILED
AND FURNISHED BY OTHERS. THE
ARCHITECT CANNOT ASSURE ITS
ACCURACY AND THEREFORE
CANNOT BE RESPONSIBLE FOR ANY
ERRORS OR OMISSIONS WHICH
HAVE BEEN INCORPORATED INTO
THIS DOCUMENT AS A RESULT.
01 RECORD DRAWING SUBMITTAL 03.10.2014
LACKLAND AIR FORCE BASE, TEXAS
37th TRAINING WING
REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO
LACKLAND AFB, TX
Velocity Con-Cor, LLC.
EXISTING ELECTRONIC GRADE DISTRIBUTION PANEL "#1",
208Y/120V, 60Hz, 1600A, 3PH., 4W., N1 ENCLOSED
1600/3
200/3
4F
225/3
4C
EXISTING ELECTRONIC GRADE DISTRIBUTION PANEL "#4",
208Y/120V, 60Hz, 1600A, 3PH., 4W., N1 ENCLOSED
1600/3
200/3
6F
225/3
6C
3000/3
1600/3
1600/3
EXISTING LOW VOLTAGE SWITCHGEAR
EXISTING SERVICE ENTRANCE
200/3
4J
6C 200/3
100/3
6C
EXISTING ELECTRONIC GRADE DISTRIBUTION PANEL "#2",
208Y/120V, 60Hz, 200A, 3PH., 4W., N1 ENCLOSED
G
10 9 8 7 6 5 4 3 2 1
F
E
D
C
B
A
10 9 8 7 6 5 4 2 1
A
B
C
D
E
F
G
APPROVALDATEDESCRIPTIONZONESYMBOL
DATE:
PROJECT NUMBER
DRAWING NUMBER
DATE
SCALE: AS NOTED
BASE CIVIL ENGINEER
APPROVED
CHIEF ENGINEERING FLIGHT (CEC)
RECOMMENDED
CHIEF CONTRACTS SECTION (CECC)
RECOMMENDED
CONSTRUCTABILITY REVIEW (CECC2)
USING AGENCY
FIRE CHIEF (CEFS)
DESIGN TEAM
ENGINEER/DESIGNER
DRAWN BY
AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE
REVISIONS
MPLS 11-014
IN SHEETS, SHEET
DO NOT SCALE DRAWING
04 APRIL 2013
RRG
LA 11-0015
This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le wi thout the Archi tect 's e x p r e s s w r i t t e n p e r m i s s i o n .
11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL
12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL
02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL
03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL
04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL
04.30.2013GENERAL REVISION1
RECORD DRAWING
07-11-2014
THESE RECORD DRAWINGS HAVE
BEEN PREPARED, IN PART, ON THE
BASIS OF INFORMATION COMPILED
AND FURNISHED BY OTHERS. THE
ARCHITECT CANNOT ASSURE ITS
ACCURACY AND THEREFORE
CANNOT BE RESPONSIBLE FOR ANY
ERRORS OR OMISSIONS WHICH
HAVE BEEN INCORPORATED INTO
THIS DOCUMENT AS A RESULT.
01 RECORD DRAWING SUBMITTAL 03.10.2014
LACKLAND AIR FORCE BASE, TEXAS
37th TRAINING WING
REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO
LACKLAND AFB, TX
Velocity Con-Cor, LLC.
G
10 9 8 7 6 5 4 3 2 1
F
E
D
C
B
A
10 9 8 7 6 5 4 2 1
A
B
C
D
E
F
G
APPROVALDATEDESCRIPTIONZONESYMBOL
DATE:
PROJECT NUMBER
DRAWING NUMBER
DATE
SCALE: AS NOTED
BASE CIVIL ENGINEER
APPROVED
CHIEF ENGINEERING FLIGHT (CEC)
RECOMMENDED
CHIEF CONTRACTS SECTION (CECC)
RECOMMENDED
CONSTRUCTABILITY REVIEW (CECC2)
USING AGENCY
FIRE CHIEF (CEFS)
DESIGN TEAM
ENGINEER/DESIGNER
DRAWN BY
AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE
REVISIONS
MPLS 11-014
IN SHEETS, SHEET
DO NOT SCALE DRAWING
04 APRIL 2013
RRG
LA 11-0015
This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le wi thout the Archi tect 's e x p r e s s w r i t t e n p e r m i s s i o n .
11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL
12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL
02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL
03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL
04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL
04.30.2013GENERAL REVISION1
RECORD DRAWING
07-11-2014
THESE RECORD DRAWINGS HAVE
BEEN PREPARED, IN PART, ON THE
BASIS OF INFORMATION COMPILED
AND FURNISHED BY OTHERS. THE
ARCHITECT CANNOT ASSURE ITS
ACCURACY AND THEREFORE
CANNOT BE RESPONSIBLE FOR ANY
ERRORS OR OMISSIONS WHICH
HAVE BEEN INCORPORATED INTO
THIS DOCUMENT AS A RESULT.
01 RECORD DRAWING SUBMITTAL 03.10.2014
LACKLAND AIR FORCE BASE, TEXAS
37th TRAINING WING
REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO
LACKLAND AFB, TX
Velocity Con-Cor, LLC.
10 9 8 7 6 5 4 3 2 1
F
E
D
C
B
A
10 9 8 7 6 5 4 2 1
A
B
C
D
E
F
G
APPROVALDATEDESCRIPTIONZONESYMBOL
DATE:
PROJECT NUMBER
DRAWING NUMBER
DATE
SCALE: AS NOTED
BASE CIVIL ENGINEER
APPROVED
CHIEF ENGINEERING FLIGHT (CEC)
RECOMMENDED
CHIEF CONTRACTS SECTION (CECC)
RECOMMENDED
CONSTRUCTABILITY REVIEW (CECC2)
USING AGENCY
FIRE CHIEF (CEFS)
DESIGN TEAM
ENGINEER/DESIGNER
DRAWN BY
AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE
REVISIONS
MPLS 11-014
IN SHEETS, SHEET
DO NOT SCALE DRAWING
04 APRIL 2013
RRG
LA 11-0015
This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le without the Architect 's e x p r e s s w r i t t e n p e r m i s s i o n .
11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL
12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL
02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL
03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL
04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL
04.30.2013GENERAL REVISION1
RECORD DRAWING
07-11-2014
THESE RECORD DRAWINGS HAVE
BEEN PREPARED, IN PART, ON THE
BASIS OF INFORMATION COMPILED
AND FURNISHED BY OTHERS. THE
ARCHITECT CANNOT ASSURE ITS
ACCURACY AND THEREFORE
CANNOT BE RESPONSIBLE FOR ANY
ERRORS OR OMISSIONS WHICH
HAVE BEEN INCORPORATED INTO
THIS DOCUMENT AS A RESULT.
01 RECORD DRAWING SUBMITTAL 03.10.2014
LACKLAND AIR FORCE BASE, TEXAS
37th TRAINING WING
REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO
LACKLAND AFB, TX
Velocity Con-Cor, LLC.
MEN
ELEC.
JAN.
WOMEN
ELEV
CORRIDOR
COMM.
(E)FD
(E)3"FCO
(E)4"V RISER; SEE
1/P-401 FOR
CONTINUATION;
(E)4"VTR
(E)2"V RISER; SEE
1/P-401 FOR
CONTINUATION;
(E)2"VTR
(E)2"SS DROP; SEE
1/P-401 FOR
CONTINUATION
(E)FD
(E)6"V RISER; SEE 1/P-401
FOR CONTINUATION
(E)CAP
(E)2"SS DROP; SEE
1/P-401 FOR
CONTINUATION
(E)2"V RISER; SEE
1/P-401 FOR
CONTINUATION;
(E)2"VTR
(E)2"SS DROP; SEE
1/P-401 FOR
CONTINUATION
(E)6"SS DROP; 1/P-401 FOR
CONTINUATION
(E)3"
(E)4"
(E)3"
(E)4"V
(E)4"(E)3"
(E)2"V
(E)4"
(E)4" (TYP.
FOR 4)
(E)2"V
(E)4"V
(E)4"V
(E)3"
(E)4"V
(E)2"
(E)2" (E)1-1/4"
(E)1-1/4"
(E)4"V
(E)2"V
(E)2"V
(E)4"V
(E)4"V
(E)4"SS DROP; SEE
1/P-401 FOR
CONTINUATION; (E)4"V
FROM TOP OF (E)4"SS
STACK
(E)2" (TYP.
FOR 5)
(E)2" (TYP.
FOR 4)
(E)4"V
(E)4"V
(E)3"
(E)4"V
(E)4"V
(E)3"
(E)3"
(E)2"
(E)1-1/4"V
(E)1-1/2"V
(E)2"
(E)1-1/4"V
(TYP. FOR 4)
(E)2"V
(E)2"V
(E)4"
(E)2"V
CAP
CAP
CAP
CAP
CAP
CAP
CAP
CAP
CAP
CAP
(E)4"
(E)4"
(E)4"V
(E)4"V
(E)3"
(E)1-1/2"CW RISER; SEE
2/P-401 FOR
CONTINUATION
(E)1"HW RISER; SEE
2/P-401 FOR
CONTINUATION
(E)1/2"CW RISER; SEE
2/P-401 FOR
CONTINUATION
(E)3/4"HWR; SEE 2/P-401
FOR CONTINUATION
(E)2"CW RISER; SEE
2/P-401 FOR
CONTINUATION
(E)1-1/2"HW RISER; SEE
2/P-401 FOR
CONTINUATION
(E)1/2"CW RISER; SEE
2/P-401 FOR
CONTINUATION
(E)1"
(E)1"
(E)1"
(E)1-1/4"
(E)1"
(E)1/2"
(E)1"
(E)FD
(E)1/2" (TYP. FOR 5)
(E)1-1/4"
(TYP. FOR 4)
(E)1" (TYP.
FOR 4)
(E)1/2" (TYP. FOR 5)
(E)1/2" (TYP.
FOR 2)
(E)1/2" (TYP.
FOR 2)
(E)1-1/4" (TYP. FOR 2)
(E)1"
(E)1-1/2"
(E)1-1/2"
(E)1-1/2"
(E)2"
(E)CAP
(E)CAP
(E)3/4"
(E)1-1/4"
(E)1-1/4"
(E)3/4"
(E)1/2"
(E)1-1/4"
(E)1-1/2"
(E)1-1/4"
(E)1-1/4"
(E)1-1/2"
CAP
CAP
CAP
CAPCAP
CAP
CAP
CLASSROOM 309
MEN
ELEC.
JAN.
WOMEN
ELEV
CORRIDOR
COMM.
G
10 9 8 7 6 5 4 3 2 1
F
E
D
C
B
A
10 9 8 7 6 5 4 2 1
A
B
C
D
E
F
G
APPROVALDATEDESCRIPTIONZONESYMBOL
DATE:
PROJECT NUMBER
DRAWING NUMBER
DATE
SCALE: AS NOTED
BASE CIVIL ENGINEER
APPROVED
CHIEF ENGINEERING FLIGHT (CEC)
RECOMMENDED
CHIEF CONTRACTS SECTION (CECC)
RECOMMENDED
CONSTRUCTABILITY REVIEW (CECC2)
USING AGENCY
FIRE CHIEF (CEFS)
DESIGN TEAM
ENGINEER/DESIGNER
DRAWN BY
AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE
REVISIONS
MPLS 11-014
IN SHEETS, SHEET
DO NOT SCALE DRAWING
04 APRIL 2013
RRG
LA 11-0015
This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le wi thout the Archi tect 's e x p r e s s w r i t t e n p e r m i s s i o n .
11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL
12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL
02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL
03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL
04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL
04.30.2013GENERAL REVISION1
RECORD DRAWING
07-11-2014
THESE RECORD DRAWINGS HAVE
BEEN PREPARED, IN PART, ON THE
BASIS OF INFORMATION COMPILED
AND FURNISHED BY OTHERS. THE
ARCHITECT CANNOT ASSURE ITS
ACCURACY AND THEREFORE
CANNOT BE RESPONSIBLE FOR ANY
ERRORS OR OMISSIONS WHICH
HAVE BEEN INCORPORATED INTO
THIS DOCUMENT AS A RESULT.
01 RECORD DRAWING SUBMITTAL 03.10.2014
LACKLAND AIR FORCE BASE, TEXAS
37th TRAINING WING
REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO
LACKLAND AFB, TX
Velocity Con-Cor, LLC.
CLASSROOM 309
MEN
ELEC.
JAN.
WOMEN
ELEV
CORRIDOR
COMM.
(E)4"V RISER; (E)4"VTR
(E)2"V RISER;
(E)2"VTR
(E)2"SS DROP
(E)6"V RISER
(E)2"SS DROP
(E)2"V RISER;
(E)2"VTR
(E)2"SS DROP; SEE
1/DP1 FOR
CONTINUATION
(E)6"SS DROP
(E)2"
(E)1-1/4"
(E)1-1/4"
(E)2"V
(E)FD
(E)4"
(E)4"
(E)2"
(E)4"V
(E)4"V
(E)4"SS; (E)4"V FROM
TOP OF (E)4"SS STACK
(E)4"V
(E)2"V
(E)4"V
(E)3"
(E)1-1/2"V
(E)3"
POC
POC
POC
POC; 2"
1-1/2"V (E)3"
(E)4"V (E)3"
(E)4"V
4" ABOVE
FLOOR
4" ABOVE
FLOOR
2"SS DROP THRU
FLOOR; CORE
DRILL AS
REQUIRED
WCO
POC
(E)4"
2"
4" ABOVE
FLOOR
4" ABOVE
FLOOR
POC
POC
POC
POC
POC
POC
POC
POC
POC
POC
POC
POC
TRAP PRIMER
LINE BELOW
FLOOR
PROVIDE TRAP
PRIMER
CONNECTION ON
SINK TAILPIECE
CLASSROOM 309
MEN
ELEC.
JAN.
WOMEN
ELEV
CORRIDOR
COMM.
(E)1/2"CW RISER
(E)FD
(E)1-1/2"
POC; 3/4"
3/4"
WHA-A
WHA-B
12" X 12" WALL
ACCESS PANEL
AP
12" X 12" WALL
ACCESS PANEL
AP
WHA-A
WHA-C
POC
POC
POC
POC
POC
POC
POC
POC
POC
POC
POC
POC
POC
TRAP PRIMER
LINE BELOW
FLOOR
PROVIDE TRAP
PRIMER
CONNECTION ON
SINK TAILPIECE
G
10 9 8 7 6 5 4 3 2 1
F
E
D
C
B
A
10 9 8 7 6 5 4 2 1
A
B
C
D
E
F
G
APPROVALDATEDESCRIPTIONZONESYMBOL
DATE:
PROJECT NUMBER
DRAWING NUMBER
DATE
SCALE: AS NOTED
BASE CIVIL ENGINEER
APPROVED
CHIEF ENGINEERING FLIGHT (CEC)
RECOMMENDED
CHIEF CONTRACTS SECTION (CECC)
RECOMMENDED
CONSTRUCTABILITY REVIEW (CECC2)
USING AGENCY
FIRE CHIEF (CEFS)
DESIGN TEAM
ENGINEER/DESIGNER
DRAWN BY
AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE
REVISIONS
MPLS 11-014
IN SHEETS, SHEET
DO NOT SCALE DRAWING
04 APRIL 2013
RRG
LA 11-0015
This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le without the Architect 's e x p r e s s w r i t t e n p e r m i s s i o n .
11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL
12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL
02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL
03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL
04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL
04.30.2013GENERAL REVISION1
RECORD DRAWING
07-11-2014
THESE RECORD DRAWINGS HAVE
BEEN PREPARED, IN PART, ON THE
BASIS OF INFORMATION COMPILED
AND FURNISHED BY OTHERS. THE
ARCHITECT CANNOT ASSURE ITS
ACCURACY AND THEREFORE
CANNOT BE RESPONSIBLE FOR ANY
ERRORS OR OMISSIONS WHICH
HAVE BEEN INCORPORATED INTO
THIS DOCUMENT AS A RESULT.
01 RECORD DRAWING SUBMITTAL 03.10.2014
LACKLAND AIR FORCE BASE, TEXAS
37th TRAINING WING
REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO
LACKLAND AFB, TX
Velocity Con-Cor, LLC.
10 9 8 7 6 5 4 3 2 1
F
E
D
C
B
A
10 9 8 7 6 5 4 2 1
A
B
C
D
E
F
G
APPROVALDATEDESCRIPTIONZONESYMBOL
DATE:
PROJECT NUMBER
DRAWING NUMBER
DATE
SCALE: AS NOTED
BASE CIVIL ENGINEER
APPROVED
CHIEF ENGINEERING FLIGHT (CEC)
RECOMMENDED
CHIEF CONTRACTS SECTION (CECC)
RECOMMENDED
CONSTRUCTABILITY REVIEW (CECC2)
USING AGENCY
FIRE CHIEF (CEFS)
DESIGN TEAM
ENGINEER/DESIGNER
DRAWN BY
AIR EDUCATION & TRAINING COMMANDUNITED STATES AIR FORCE
REVISIONS
MPLS 11-014
IN SHEETS, SHEET
DO NOT SCALE DRAWING
04 APRIL 2013
RRG
LA 11-0015
This electronic drawing file is released under the authority of Robert A. Lopez, AIA #16232, who maintains a hard copy of the or iginal f i le. The user of th is electronic drawing file agrees to assume all responsibility for any modification to or use of this drawing file.No person may make any modification to this electronic drawing f i le without the Architect 's e x p r e s s w r i t t e n p e r m i s s i o n .
11.13.201260% CONSTRUCTION DOCUMENT SUBMITTAL
12.21.201260% CONSTRUCTION DOCUMENT RE-SUBMITTAL
02.03.2013100% CONSTRUCTION DOCUMENT SUBMITTAL
03.04.2013100% CONSTRUCTION DOCUMENT RE - SUBMITTAL
04.04.2013100% CONSTRUCTION DOCUMENT SUBMITTAL-FINAL
04.30.2013GENERAL REVISION1
RECORD DRAWING
07-11-2014
THESE RECORD DRAWINGS HAVE
BEEN PREPARED, IN PART, ON THE
BASIS OF INFORMATION COMPILED
AND FURNISHED BY OTHERS. THE
ARCHITECT CANNOT ASSURE ITS
ACCURACY AND THEREFORE
CANNOT BE RESPONSIBLE FOR ANY
ERRORS OR OMISSIONS WHICH
HAVE BEEN INCORPORATED INTO
THIS DOCUMENT AS A RESULT.
01 RECORD DRAWING SUBMITTAL 03.10.2014
LACKLAND AIR FORCE BASE, TEXAS
37th TRAINING WING
REPAIR / RENOVATE 3rd FLOOR BLDG 9225, JIEDDO
LACKLAND AFB, TX
Velocity Con-Cor, LLC.