Attachment 03 - Labeling.pdf

PDF 215 KB Posted

Attached to
MPLS208151 - Renovate Controlled Area, Building 9225 Federal contract opportunity
Solicitation number
FA301621B0001
Issued by
Department of the Air Force Air Education and Training Command

About this file

This document outlines requirements for a federal construction contract opportunity to renovate a controlled area at Joint Base San Antonio Lackland Air Force Base. The solicitation seeks design-build services for renovating a controlled area in Building 9225, with a project magnitude between $500,000 and $1,000,000. The work is subject to the Construction Wage Rate Requirement and Texas prevailing wage rates. The acquisition is set aside for women-owned small businesses. Offerors must be certified through the WOSB Program Repository and submit eligibility documentation. Proposals are due by the closing date and must include completed SF1442 forms, pricing details by CLIN, and applicable representations and certifications.

View the file

Other files for this federal contract opportunity

Other files attached to MPLS208151 - Renovate Controlled Area, Building 9225, newest first.
File Type Posted
Site Visit Questions - Renovate Controlled Area - 26Mar2021.pdf PDF
Attachment 01 - Revised Statement of Work 26 March 2021.pdf PDF
Attachment 04 - Revised Patch Panel and Multiple Input-Output (MIO)_Zone Boxes (Appendix D).pdf PDF
Attachment 7 - Revised Submittal Register 20210326.pdf PDF
Attachment 18 - Partial Mech.pdf PDF
Attachment 14 - Revised Wage Determination.pdf PDF
FA301621B00010003.pdf PDF
Attachment 02 - Revised Concept Drawings (Appendix A).pdf PDF
Attachment 16 - Section L - Instructions to Offerors Rev 26Mar2021.pdf PDF
Attachment 19 - MEP Record Drawings.pdf PDF
Site Visit Questions - Renovate Controlled Area - ANSWERED.docx DOCX document
FA301621B00010002.pdf PDF
FA301621B00010001.pdf PDF
FA301621B0001.pdf PDF
Attachment 09 - Asbestos Report.pdf PDF
Attachment 10 - Lead Based Paint Report.pdf PDF
Attachment 16 - Section L - Instructions to Offerors.pdf PDF
Attachment 2 - Concept Drawings.pdf PDF
Attachment 11 - General Requirement for Obtaining Waste Manifest.pdf PDF
Attachment 1 - Statement of Work.pdf PDF
Attachment 05 - CAD_Templates_and_Reqs.zip ZIP file
Attachment 07 - Submittal Register.pdf PDF
Attachment 08 - DD1354.pdf PDF
Attachment 14 - Wage Determination.pdf PDF
Attachment 04 - Patch Panel and Multiple Input-Output (MIO)_Zone Boxes.pdf PDF
Attachment 06 - Installation Guidelines.pdf PDF
Attachment 12 - Bldg 9225 Record Dwg Binder 20140711.pdf PDF
Attachment 13 - Climatological Data 2019 - 2020.pdf PDF
Attachment 15 - Construction Cost Estimate Breakdown.xls XLS spreadsheet
Attachment 17 - Section M - Evaluation Factors for Award.pdf PDF
Show all 30

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Labeling

Label telecommunications systems in accordance with TIA/EIA-606. All labeling must be a minimum of

¼-inch (6mm) high, handwritten labels must not be used for the final configuration.

Label the front of all patch panels and MIO/zone boxes with the appropriate classification form as follows: TS/SCI = SF712 or Secret/Collateral = SF707; if TS/SCI and Secret are housed in the same

MIO/zone box the box will be labeled as TS/SCI. Label the front of each MIO/zone box with a unique ID and patch panel with a unique ID within that cabinet. Label the front of each patch panel with the applicable classification. Annotate on the patch panel’s port labeling placard the distant MIO/zone box

ID number and associated ports for each applicable module installed. Label the front of each MIO/zone box with the following information as applicable: distant room number; cabinet ID and patch panel ID;

port number; and classification.

Label all outlet faceplates with their classification and each individual outlet/connector will be labeled with the horizontal link identifier. The labeling shall appear on the faceplate in a way that clearly identifies the individual connector associated with the particular identifier. Label all backbone trunk cables at each end with the following information as applicable distant end room number; cabinet ID, patch panel/module or MIO/zone box ID and module slot location. Any exposed cabling that is not color-coded for a classification will be also marked with appropriate color tape to identify its classification IAW

CNSSAM TEMPEST/1-13 para 3.2 & 3.5.