Attachment 02 - Revised Concept Drawings (Appendix A).pdf

PDF 768 KB Posted

Attached to
MPLS208151 - Renovate Controlled Area, Building 9225 Federal contract opportunity
Solicitation number
FA301621B0001
Issued by
Department of the Air Force Air Education and Training Command

About this file

This document contains concept drawings and a federal contract opportunity solicitation. The concept drawings are for the renovation of a controlled area in Building 9225 on Joint Base San Antonio Lackland Air Force Base, including demolition and new floor plans. The related solicitation is for the design-build renovation between $500,000 to $1,000,000, requiring compliance with Davis-Bacon wage rates. As a Women-Owned Small Business set-aside, eligibility must be verified in the WOSB Program Repository. Offerors must complete SF1442 blocks and price line items in section B, and include proposals and certifications per the instructions in sections I, K and L. The soliciting agency is the Air Force Air Education and Training Command.

View the file

Other files for this federal contract opportunity

Other files attached to MPLS208151 - Renovate Controlled Area, Building 9225, newest first.
File Type Posted
Site Visit Questions - Renovate Controlled Area - 26Mar2021.pdf PDF
Attachment 01 - Revised Statement of Work 26 March 2021.pdf PDF
Attachment 04 - Revised Patch Panel and Multiple Input-Output (MIO)_Zone Boxes (Appendix D).pdf PDF
Attachment 7 - Revised Submittal Register 20210326.pdf PDF
Attachment 18 - Partial Mech.pdf PDF
Attachment 14 - Revised Wage Determination.pdf PDF
FA301621B00010003.pdf PDF
Attachment 16 - Section L - Instructions to Offerors Rev 26Mar2021.pdf PDF
Attachment 19 - MEP Record Drawings.pdf PDF
Site Visit Questions - Renovate Controlled Area - ANSWERED.docx DOCX document
FA301621B00010002.pdf PDF
FA301621B00010001.pdf PDF
FA301621B0001.pdf PDF
Attachment 09 - Asbestos Report.pdf PDF
Attachment 10 - Lead Based Paint Report.pdf PDF
Attachment 16 - Section L - Instructions to Offerors.pdf PDF
Attachment 2 - Concept Drawings.pdf PDF
Attachment 03 - Labeling.pdf PDF
Attachment 11 - General Requirement for Obtaining Waste Manifest.pdf PDF
Attachment 1 - Statement of Work.pdf PDF
Attachment 05 - CAD_Templates_and_Reqs.zip ZIP file
Attachment 07 - Submittal Register.pdf PDF
Attachment 08 - DD1354.pdf PDF
Attachment 14 - Wage Determination.pdf PDF
Attachment 04 - Patch Panel and Multiple Input-Output (MIO)_Zone Boxes.pdf PDF
Attachment 06 - Installation Guidelines.pdf PDF
Attachment 12 - Bldg 9225 Record Dwg Binder 20140711.pdf PDF
Attachment 13 - Climatological Data 2019 - 2020.pdf PDF
Attachment 15 - Construction Cost Estimate Breakdown.xls XLS spreadsheet
Attachment 17 - Section M - Evaluation Factors for Award.pdf PDF
Show all 30

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TCCPBWWBBTCXT2UPSMTT

SAN ANTONIO

M

E

D

I

N

A

RIV

ER

S

A

N

A

N

T

O

N

I O

R

IV

E R

G

U

A

D

A

L

U

P

E

C

R

E

E

K

R

I

V

E

R

GUADALUPE

C

I B

O

L

O

CREEK

KENDALL

RIVER

B

A

L C

O

N

E

S

C

R

E

E

K

C

I

B

O

L

O

WILSON

C

I

B

O

L

O

C

R

E

E

K

BEXAR

COMAL

CALAVERAS

LAKE

Brooks AFB

Randolph AFB

International Airport

San Antonio

New

Braunfels

Seguin

Stockdale

Boerne

CANYON LAKE

REC. AREA

FORT SAM

HOUSTON

CAMP

BULLIS

LACKLAND AFB

Kelly

AFB

10904

10416

10215

10207

10900

10504

10902

10634

10810

10175

10345

10201

10255

10251

10265

10261

10263

10334

10534

10547

10055

10075

10050

10070

10338

10800

10205

10385

10253

10380

10652

10802

10656

10806

10650

10501

10540

10395

10330

10541

10203

10065

10060

10670

10390

10346

10658

10701

10056

10705

10808

10375

10903

10185

10654

10700

10638

10260

10210

10177

10725

10811

10799

10801

10007

10549

46504335

10727

10708

G-001

Y

L I Z

A S

U A

I N

C

U

M I P

E G

D

2 3 4 5

C

B

A

D a t e

A P

P R

O V

E D

A S

B

U I L T

A p p r o v a l

D a t e

D e s c r i p t i o n

R e v

Reference Number:

Sheet of

F I L

E

N

A M

E

D W

N

B

Y

D E

S I G

N E

D

B

Y

R E

L E

A S

E D

B

Y

C K

D

B

Y

W O

R K

O

D

N

U M

B E

R

C O

N T

R A

C T

M

B E

R

D R

A W

I N

G

C

O D

E

D A

T E

PROJECT NUMBER

F S

N

D

C

B

A

1 2 3 4 5

X I I

X

I

X

IX

V

I

I

I

V

I

I

V I

V

I

V

III

I

I

I

J O

I N

T

B

A S

E

S

A

T

O N

I O d

C

I V

I L

E

N G

I N

E E

R

S

Q

S A

N

A

N T

O N

I O

X

S

I G

N E

D

MPLS208151

R E

N O

V A

O

M S

L D

G

J O

I N

T

B

A S

E

S

T

O N

I O

G E

N E

R A

L

C O

V E

R

S

H E

E T

DRAWING INDEX

SHEET ID SHEET TITLE

GENERAL

G-001

COVER SHEET

ARCHITECTURAL

A-101

CONCEPT FLOOR PLAN - DEMOLITION

A-102

CONCEPT FLOOR PLAN - NEW

LACKLAND AIR FORCE BASE

PROJECT

LOCATION

Scale: N.T.S

JOINT BASE SAN ANTONIO

LACKLAND AIR FORCE BASE

802d CIVIL ENGINEER SQ.

SAN ANTONIO, TX

MPLS208151 RENOVATE ROOMS BLDG 9225

JOINT BASE SAN ANTONIO

AutoCAD SHX Text ELECTRICAL: TRANSFORMER, PLAN TRANSFORMER, ONE-LINE DIAGRAM UNDER FLOOR JUNCTION BOX JUNCTION BOX PULL BOX TROLLEY DUCT LADDER CABLE TRAY WIREWAY BUSWAY PUSH BUTTON FLUSH MOUNTED PANEL SURFACE MOUNTED PANEL UNINTERRUPTIBLE POWER SUPPLY GENERATOR CIRCUIT BREAKER FUSED DISCONNECT SWITCH UN-FUSED DISCONNECT SWITCH ELECTRICAL TIME CLOCK

AutoCAD SHX Text N

AutoCAD SHX Text

A-101

Y

L I Z

A S

U A

I N

C

U

M I P

E G

D

2 3 4 5

C

B

A

D a t e

A P

P R

O V

E D

A S

B

U I L T

A p p r o v a l

D a t e

D e s c r i p t i o n

R e v

Reference Number:

Sheet of

F I L

E

N

A M

E

D W

N

B

Y

D E

S I G

N E

D

B

Y

R E

L E

A S

C K

D

B

Y

W O

D

M

B E

R

C O

N T

R A

M

B E

R

D R

A W

I N

G

C

O D

E

D A

T E

PROJECT NUMBER

F S

N

D

C

B

A

1 2 3 4 5

X I I

X

I

X

IX

V

I

I

I

V

I

I

V I

V

I

V

III

I

I

I

J O

I N

T

B

A S

E

S

T

O N

I O d

C

I V

I L

E

N G

I N

E E

R

S

Q

S A

N

A

N T

O N

I O

S

I G

N E

D

MPLS208151

R E

N O

V A

O

D

G

J O

I N

T

B

A S

E

S

T

O N

I O

A R

C H

I T

E C

T U

R A

L

C O

N C

E P

T

F

L O

P

A

N

D

E M

O L I T

I O

N

CONCEPT FLOOR PLAN - DEMOLITION

Scale: N.T.S

AutoCAD SHX Text

LEGEND LEGEND EXISTING DEMOLISH

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

CONSTRUCTION STATUS

AutoCAD SHX Text

NOT FOR CONSTRUCTION

AutoCAD SHX Text KEYED NOTES: DEMOLISH MODULAR WALLS DEMOLISH OPENING FOR DOOR REMOVE WALL MOUNTED VINDICATOR,STORE FOR REINSTALLATION INTO ROOM 320.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

GENERAL NOTES: 1. DEMOLISH REFLECTED CEILINGS IN ALL ROOMS EXCEPT FOR DEMOLISH REFLECTED CEILINGS IN ALL ROOMS EXCEPT FOR ROOM 322.

A-102

Y

L I Z

A S

U I A

N

C

U

M I P

E G

D

2 3 4 5

C

B

A

D a t e

A P

P R

O V

E D

A S

B

U I L T

A p p r o v a l

D a t e

D e s c r i p t i o n

R e v

Reference Number:

Sheet of

F I L

E

N

A M

E

D W

N

B

Y

D E

S I G

N E

D

B

Y

R E

L E

A S

C K

D

B

Y

W O

D

M

B E

R

C O

N T

R A

M

B E

R

D R

A W

I N

G

C

O D

E

D A

T E

PROJECT NUMBER

F S

N

D

C

B

A

1 2 3 4 5

X I I

X

I

X

IX

V

I

I

I

V

I

I

V I

V

I

V

III

I

I

I

J O

I N

T

B

A S

E

S

T

O N

I O d

C

I V

I L

E

N G

I N

E E

R

S

Q

S A

N

A

N T

O N

I O

S

I G

N E

D

MPLS208151

R E

N O

V A

O

D

G

J O

I N

T

B

A S

E

S

T

O N

I O

A R

C H

I T

E C

T U

R A

L

C O

N C

E P

T

F

L O

P

A

N

N

E W

CONCEPT FLOOR PLAN - NEW

Scale: N.T.S

MARK

SIZE

W HT RATE

101 4'-0" STC 45

102 3'-0" 7'-0" STC 45

103 3'-0" STC 507'-0"

7'-0"

101 101

103 103

DOOR SCHEDULE

AutoCAD SHX Text

LEGEND LEGEND EXISTING NEW

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

CONSTRUCTION STATUS

AutoCAD SHX Text

NOT FOR CONSTRUCTION

AutoCAD SHX Text KEYED NOTES: NEW WALL TO BE PLACED IN EXACT LOCATION OF PREVIOUS MODULAR WALL. REINSTALL STORED VINDICATOR. INSTALL NEW VINDICATOR PROPOSED NEW COMM RACKS TO BE INSTALLED IN ACCORDANCE WITH ICD70 STANDARDS. ALL INTERIOR WALLS ARE TO HAVE A STC45 RATING. ALL INTERIOR WALLS ARE TO HAVE A STC50 RATING. INSTALL NEW WALL MOUNTED 208/120V, 100A, 3PH, 4W PANEL INSTALL NEW WALL MOUNTED 208/120V, 225A, 3PH, 4W PANEL

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text GENERAL NOTES: 1. ALL ROOMS ARE TO BE TO ICD70 STANDARDS.ALL ROOMS ARE TO BE TO ICD70 STANDARDS.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

NIPRNIPR

AutoCAD SHX Text

SIPR

AutoCAD SHX Text

JWICSJWICS

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

Sheets and Views
MPLS208151- B9225 Concept Drawings-G-001
MPLS208151- B9225 Concept Drawings-A-101 CONCEPT-FP-DEMO
MPLS208151- B9225 Concept Drawings-A-101 CONCEPT-FP-NEW

File details come from the government source that posted it. Updated .