WINDOW SIGNAGE ALLOWANCE

PER PHILADELPHIA CODE 14-904

GLASS AREA 11.3+11.3+12.1+12.1 = 46.8 SF

MAX. SIGNAGE AREA (20%) 9.36 SF

PROPOSED SIGNAGE AREA .7 = .7 SF - IN COMPLIANCE

DRAWN BY:

SCALE:

N O

T

FO

R C

O N

ST

R

UC

TI

O N

PROJECT:

SWRL STUDIO, LLC

2715 Folsom St Philadelphia, PA 19130

©2026

DATE:

PROJECT NO:

NOTES:

swrl studio

NO. DATE DESCRIPTION

ARCHITECT

STRUCTURAL ENGINEER

PRESTON STRUCTURAL SOLUTIONS, LLC

106 Gay Street, Unit 305 Philadelphia, PA 19127

1/4" = 1'-0"

A000

DH

COVER SHEET

2323 RIDGE

McCoys

2323 RIDGE AVE

PHILADELPHIA, PA 19121

10/24/26 2026_02

PROJECT LOCATION

PHILADELPHIA, PA 19121

SCOPE:

EXTERIOR RENOVATION OF EXISTING AUTO SERVICE CENTER INCLUDING NEW

WALL SIGNAGE AND WINDOW SIGNAGE

APPLICABLE CODE SUMMARY:

PHILADELPHIA BUILDING CODE (2021 INTERNATIONAL BUILDING CODE)

PHILADELPHIA EXISTING BUILDING CODE (2021 INTERNATIONAL EXISTING BUILDING CODE)

PHILADELPHIA ELECTRICAL CODE (2020 NATIONAL ELECTRIC CODE)

PROJECT DATA:

JURISDICTION: CITY OF PHILADELPHIA

ZONING: CMX-2 NEIGHBORHOOD COMMERCIAL MIXED-USE

BUSINESS NAME: McCOY'S AUTO & TIRE SERVICE CENTER

PHOTO : EXISTING RENDERING : PROPOSED - BASE SCOPE

2323 RIDGE AVE BASE SCOPE - DEMO

DB-02 UNINSTALL EXISTING WALL SIGNS

BASE SCOPE - PROPOSED

B-01 NEW FLAT WALL SIGNAGE

B-02 PREP & PAINT EXISTING OH ROLLING GATE. INSPECT FOR PROPER FUNCTION

B-04 NEW EXTERIOR LIGHTING - 1 FIXTURE

B-05 NEW VINYL WINDOW SIGNAGE

B-07 PATCH, REPAIR AND PAINT STUCCO. COLOR = OFF WHITE

B-10 PAINT EXISTING GUTTERS, FASCIA, DOWNSPOUTS AND BOLLARDS. COLOR =

RED = BENJAMIN MOORE VERMILION 2002-10

AD-ALT SCOPE - PROPOSED

A-01 NEW BLACK METAL FENCING AND SLIDING GATE, SEE PLAN.

A-02 NEW RAILING ON EXISTING RAMP FOR ADA COMPLIANCE. VERIFY SLOPE COMPLIES WITH NO GREATER

THAN 1" RISE TO 12" RUN SLOPE

A-03 REINSTALL EXISTING INSPECTION STATION SIGN, MOUNT TO WALL

A-04 NEW VINYL SIGNAGE ON OH ROLLING GATES

A-05 NEW FREESTANDING POLE SIGN. NEW FOUNDATION, POLE AND SIGNAGE

A-06 PATCH, REPAIR AND PAINT EXISTING DOOR

A-07 NEW DIAMOND PLATE WALL PROTECTION COVERS AS COLUMN WRAPS BETWEEN GARAGE DOORS, TYP.SHEET INDEX

SHEET

NUMBER SHEET NAME BI

D S

ET

0/

/2

A000 COVER SHEET ●

A101 EXTERIOR ELEVATIONS ●

A102 PLANS AND ENLARGED DRAWINGS ●

A103 DETAILS ●

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

GENERAL NOTES:

ALL DRAWINGS ARE TO SCALE AS INDICATED. THE CONTRACTOR MUST

VERIFY THE SCALE BEFORE BEGINNING CONSTRUCTION. DO NOT SCALE

DIRECTLY FROM THE DRAWINGS.

IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN ALL

PERMITS FOR PLUMBING AND ELECTRICAL WORK, AND ANY OTHER WORK

NOT PERMITTED UNDER A GENERAL BUILDING PERMIT.

WORK NOT INDICATED ON A PART OF THE DRAWINGS BUT REASONABLY

IMPLIED TO BE SIMILAR TO THAT SHOWN AT CORRESPONDING PLACES,

SHALL BE REPEATED.

CONTRACTOR SHALL COORDINATE OPENINGS SHOWN ON THE DRAWINGS.

CONTRACTOR SHALL VERIFY AND/OR ESTABLISH ALL EXISTING CONDITIONS

AND DIMENSIONS AT THE SITE.

IF THE EXISTING FIELD CONDITIONS DO NOT PERMIT THE INSTALLATION OF

THE WORK IN ACCORDANCE WITH THE DETAILS SHOWN, THE CONTRACTOR

SHALL NOTIFY THE ARCHITECT IMMEDIATELY AND PROVIDE A SKETCH OF

THE CONDITION WITH CONTRACTOR’S PROPOSED MODIFICATION OF THE

DETAILS GIVEN ON THE CONTRACT DOCUMENTS.

IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND ALL

SUB-CONTRACTORSTO COORDINATE THE WORK AND VERIFY ALL

DIMENSIONS AND INSPECT CONDITIONS OF PRIOR WORK BY ALL TRADES

BEFORE PROCEEDING WITH ANY WORK. UNACCEPTABLE OR INCORRECT

PRIOR WORK SHALL BE REPAIRED OR REPLACED BEFORE STARTING WORK.

PROCEEDING WITH THE WORK SHALL CONSTITUTE ACCEPTANCE OF PRIOR

WORK.

WHERE WORK INVOLVES EXISTING SUPPORTING STRUCTURE, THE

CONTRACTOR SHALL PROVIDE SHORING AND PROTECTION REQUIRED TO

INSURE THE STRUCTURAL INTEGRITY OF THE EXISTING STRUCTURE.

UNLESS SPECIFICALLY SHOWN OR NOTED ON THE DRAWINGS, NO

STRUCTURAL MEMBER SHALL BE CUT, NOTCHED, BORED OR OTHERWISE

MODIFIED WITHOUT THE PERMISSION OF THE STRUCTURAL ENGINEER OF

RECORD

ALL PRODUCTS AND MATERIALS TO BE INSTALLED FOLLOWING

MANUFACTURERS' RECOMMENDATIONS.

CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES IN

THE DOCUMENTS PRIOR TO PROCEEDING WITH ANY WORK INVOLVED.

THE PURPOSE OF THESE DRAWINGS IS FOR THE CONTRACTOR TO INCLUDE

ALL THE LABOR, MATERIALS AND SERVICES REQUIRED FOR THE

COMPLETION OF ALL WORK SHOWN OR REASONABLY IMPLIED BUT NOT

LIMITED TO THAT EXPLICITLY SHOWN IN THE DOCUMENTS.

1.

2.

3.

4.

5.

PROJECT NOTES:

"BASE SCOPE" MEANS THE MINIMUM SCOPE OF WORK. ADDITIONAL SCOPE

MAY BE REQUIRED TO COMPLY WITH CODE, LIFE SAFETY AND STRUCTURAL

REQUIREMENTS.

"AD-ALT SCOPE" MEANS ADDITIONAL AND ALTERNATIVE SCOPE. THE

OWNER HAS THE RIGHT TO INCLUDE OR EXCLUDE ANY OR ALL ITEMS

IDENTIFIED IN THE FINAL SCOPE OF WORK

PAINTING APPLIES TO FIRST LEVEL ONLY UNLESS NOTED OTHERWISE

FOR NEW OR REPLACEMENT GATES, INSTALL SEE-THROUGH GRILLES ONLY

WINDOW DECALS TO HAVE CLEAR BACKGROUNDS RATHER AN OPAQUE

PANELS OR FULL-WINDOW COVERING, TYP.

AD-ALT SCOPE - DEMO

DA-01 DEMOLISH EXISTING BLACK METAL FENCING AND GATE

DA-02 REMOVE DECOMMISSIONED ATM

DA-03 UNINSTALL EXISTING STATE INSPECTION SITE SIGN, STORE AND PROTECT AND PREPARE SIGN FOR

REINSTALLATION

DA-04 DEMOLISH EXISTING FREESTANDING POLE SIGN. PATCH AND REPAIR CONCRETE

RENDERING : PROPOSED FULL SCOPE

DA-01

DA-04

DB-02DB-02

EXISTING FLOODLIGHTS

TO REMAIN, TYP.

WALL IN

PERSPECTIVE

4'

0"

2' - 0" V.I.F.

B-10B-10

B-07B-07

B-02B-02

A-04

B-07B-07 B-01B-01 B-10B-10

A-07

B-10B-10 A-06A-02

A-03A-05

A-01

B-04B-04

B-05

.7 sf 1.3 sf

WALL IN

PERSPECTIVE

DB-02

DA-03

DA-04

DA-02

WALL IN

PERSPECTIVE

B-07B-07

B-02B-02

A-04

A-05

B-10

WINDOW SIGNAGE ALLOWANCE

PER PHILADELPHIA CODE 14-904

GLASS AREA 11.3+11.3+12.1+12.1 = 46.8 SF

MAX. SIGNAGE AREA (20%) 9.36 SF

PROPOSED SIGNAGE AREA .7 = .7 SF - IN COMPLIANCE

DRAWN BY:

SCALE:

N O

T

FO

R C

O N

ST

R

UC

TI

O N

PROJECT:

SWRL STUDIO, LLC

2715 Folsom St Philadelphia, PA 19130

©2026

DATE:

PROJECT NO:

NOTES:

swrl studio

NO. DATE DESCRIPTION

ARCHITECT

STRUCTURAL ENGINEER

PRESTON STRUCTURAL SOLUTIONS, LLC

106 Gay Street, Unit 305 Philadelphia, PA 19127

1/4" = 1'-0"

A101

FC

EXTERIOR

ELEVATIONS

2323 RIDGE

McCoys

2323 RIDGE AVE

PHILADELPHIA, PA 19121

10/24/26 2026_02

SCALE: 1/4" = 1'-0"

1 ELEVATION - N BONSALL ST - DEMO

SCALE: 1/4" = 1'-0"

2 ELEVATION - N BONSALL ST - PROPOSED

SCALE: 1/4" = 1'-0"

3 ELEVATION - RIDGE AVE - DEMO

SCALE: 1/4" = 1'-0"

4 ELEVATION - RIDGE AVE - PROPOSED

NOTE: SEE SCOPE DESCRIPTIONS ON A102

A101

A101

A101

A101

EXISTING SLIDING CHAIN LINK

GATE TO REMAIN

EXISTING SLIDING CHAIN LINK

FENCH TO REMAIN

EXISTING BOLLARDS TO REMAIN

GARAGEOFFICE

A103

DA-03

DA-04

DA-02

DA-01

EXISTING RAMP

1" / 12"

A101

A101A101

A101

1" / 12"

SLID

IN

G G

ATE

16' - 0"

23' - 9" V.I.F.

38' - 0" V.I.F.

SLID

IN

G D

IR

EC

TIO

N

GARAGEOFFICE

/3 A103A-05

A-03

SEE

A-02

A-01

B-10B-10

DRAWN BY:

SCALE:

N O

T

FO

R C

O N

ST

R

UC

TI

O N

PROJECT:

SWRL STUDIO, LLC

2715 Folsom St Philadelphia, PA 19130

©2026

DATE:

PROJECT NO:

NOTES:

swrl studio

NO. DATE DESCRIPTION

ARCHITECT

STRUCTURAL ENGINEER

PRESTON STRUCTURAL SOLUTIONS, LLC

106 Gay Street, Unit 305 Philadelphia, PA 19127

3/16" = 1'-0"

A102

FC

PLANS AND

ENLARGED

DRAWINGS

2323 RIDGE

McCoys

2323 RIDGE AVE

PHILADELPHIA, PA 19121

10/24/26 2026_02

SCALE: 3/16" = 1'-0"

1 FLOOR PLAN - DEMO

SCALE: 3/16" = 1'-0"

2 FLOOR PLAN - PROPOSED

BASE - PROPOSED

B-01 NEW FLAT WALL SIGNAGE

B-02 PREP & PAINT EXISTING OH ROLLING GATE. INSPECT FOR PROPER

FUNCTION

B-04 NEW EXTERIOR LIGHTING - 1 FIXTURE

B-05 NEW VINYL WINDOW SIGNAGE

B-07 PATCH, REPAIR AND PAINT STUCCO. COLOR = OFF WHITE

B-10 PAINT EXISTING GUTTERS, FASCIA, DOWNSPOUTS AND BOLLARDS. COLOR =

RED = BENJAMIN MOORE VERMILION 2002-10

BASE - DEMO

DB-02 UNINSTALL EXISTING WALL SIGNS

SCOPE - AD-ALT - PROPOSED

A-01 NEW BLACK METAL FENCING AND SLIDING GATE, SEE PLAN.

A-02 NEW RAILING ON EXISTING RAMP FOR ADA COMPLIANCE. VERIFY SLOPE

COMPLIES WITH NO GREATER THAN 1" RISE TO 12" RUN SLOPE

A-03 REINSTALL EXISTING INSPECTION STATION SIGN, MOUNT TO WALL

A-04 NEW VINYL SIGNAGE ON OH ROLLING GATES

A-05 NEW FREESTANDING POLE SIGN. NEW FOUNDATION, POLE AND SIGNAGE

A-06 PATCH, REPAIR AND PAINT EXISTING DOOR

A-07 NEW DIAMOND PLATE WALL PROTECTION COVERS AS COLUMN WRAPS

BETWEEN GARAGE DOORS, TYP.

AD-ALT - DEMO

DA-01 DEMOLISH EXISTING BLACK METAL FENCING AND GATE

DA-02 REMOVE DECOMMISSIONED ATM

DA-03 UNINSTALL EXISTING STATE INSPECTION SITE SIGN, STORE AND

PROTECT AND PREPARE SIGN FOR REINSTALLATION

DA-04 DEMOLISH EXISTING FREESTANDING POLE SIGN. PATCH AND REPAIR

CONCRETE

V.

I.F

70"

76" V.I.F.

V.

I.F

7' - 4" V.I.F. 6' - 1" V.I.F.12"

1" / 12"

EXISTING RAMP. VERIFY

SLOPE COMPLIANCE WITH

1' RISE TO 12' RUN

4'

0"

8' - 0"

SCALE: 1/2" = 1'-0"

1 RAMP CROSS SECTION

SCALE: 1/2" = 1'-0"

2 RAMP ELEVATION

SCALE: 1/2" = 1'-0"

3 FREESTANDING POLE SIGN

DRAWN BY:

SCALE:

N O

T

FO

R C

O N

ST

R

UC

TI

O N

PROJECT:

SWRL STUDIO, LLC

2715 Folsom St Philadelphia, PA 19130

©2026

DATE:

PROJECT NO:

NOTES:

swrl studio

NO. DATE DESCRIPTION

ARCHITECT

STRUCTURAL ENGINEER

PRESTON STRUCTURAL SOLUTIONS, LLC

106 Gay Street, Unit 305 Philadelphia, PA 19127

1/2" = 1'-0"

A103 Author

DETAILS

2323 RIDGE

McCoys

2323 RIDGE AVE

PHILADELPHIA, PA 19121

10/24/26 2026_02

A000 - COVER SHEET
A101 - EXTERIOR ELEVATIONS
A102 - PLANS AND ENLARGED DRAWINGS
A103 - DETAILS