WINDOW SIGNAGE ALLOWANCE
PER PHILADELPHIA CODE 14-904
GLASS AREA 6.6+10.9+12.9+5.5+5.4+5.5+15.8+15.8+15.8 = 94.2 SF
MAX. SIGNAGE AREA (20%) 18.8 SF
PROPOSED SIGNAGE AREA 1.2+.7 = 1.9 SF - IN COMPLIANCE
DRAWN BY:
SCALE:
N O
T
FO
R C
O N
ST
R
UC
TI
O N
PROJECT:
SWRL STUDIO, LLC
2715 Folsom St Philadelphia, PA 19130
©2026
DATE:
PROJECT NO:
NOTES:
swrl studio
NO. DATE DESCRIPTION
ARCHITECT
STRUCTURAL ENGINEER
PRESTON STRUCTURAL SOLUTIONS, LLC
106 Gay Street, Unit 305 Philadelphia, PA 19127
1/4" = 1'-0"
A000
DH
COVER SHEET
2163 RIDGE
KORMAN'S
2163 RIDGE AVE
PHILADELPHIA, PA 19121
10/24/26 2026_02
2163 RIDGE AVE
SHEET INDEX
SHEET
NUMBER SHEET NAME BI
D S
ET
0/
/2
A000 COVER SHEET ●
A101 EXTERIOR ELEVATIONS ●
A102 EXTERIOR ELEVATIONS - PROPOSED ●
A103 PLANS AND ENLARGED DRAWINGS ●
S001 GENERAL NOTES ●
S100 STRUCTURAL PLANS ●
S200 FACADE ELEVATIONS ●
S300 STRUCTURAL SECTIONS ●
PHILADELPHIA, PA 19121
SCOPE:
EXTERIOR RENOVATION OF EXISTING RETAIL STORE INCLUDING NEW
EXTERIOR WALL SIGN AND WINDOW SIGNAGE
APPLICABLE CODE SUMMARY:
PHILADELPHIA BUILDING CODE (2021 INTERNATIONAL BUILDING CODE)
PHILADELPHIA EXISTING BUILDING CODE (2021 INTERNATIONAL EXISTING BUILDING CODE)
PHILADELPHIA ELECTRICAL CODE (2020 NATIONAL ELECTRIC CODE)
PROJECT DATA:
JURISDICTION: CITY OF PHILADELPHIA
ZONING: CMX-3 COMMUNITY COMMERCIAL MIXED-USE
BUSINESS NAME: LEE KORMAN'S DISCOUNT
PROJECT LOCATION
AD-ALT SCOPE - DEMO
DA-01 REMOVE EXISTING ANGLED WALL SIGN TO REVEAL METAL CORNICE ON 22ND ST
DA-02 REMOVE BROKEN LIGHT UP SIGN. PATCH AND REPAIR WALL AS NECESSARY
DA-03 REMOVE EXISTING RESIDENTIAL COLLAPSIBLE GATE
DA-05 REMOVE EXISTING WALL SLATS
DA-06 REMOVE EXISTING OVERHEAD ROLLING DOORS ON 22ND ST
DA-07 REMOVE EXISTING INFILL WALL
DA-09 REMOVE EXISTING CELLAR DOORS
BASE SCOPE - DEMO
DB-01 REMOVE EXISTING ANGLED WALL SIGN TO REVEAL METAL CORNICE ON RIDGE AVE
BASE SCOPE - PROPOSED
B-01 NEW 1/2" PVC WALL SIGNAGE ON RIDGE AVE
B-02 PREP & PAINT EXISTING OH ROLLING GATE. INSPECT FOR PROPER FUNCTION
B-03 NEW ALUMINUM AWNING TO COVER OH ROLLING GATE - 18' ON RIDGE AVE
B-04 NEW LIGHTING INSTALLED ON UNDERSIDE OF AWNING - 4 FIXTURES
B-05 NEW VINYL WINDOW SIGNAGE
AD-ALT SCOPE - PROPOSED
A-01 PATCH AND REPAIR EXISTING METAL CORNICE. PROVIDE NEW ROOFING AND FLASHING
A-02 NEW INFILL WALL: METAL FRAMING, INSULATION, INTERIOR DRYWALL, EXTERIOR CEMENT BOARD PANELING
A-03 NEW THIN BRICK VENEER. BOD: GLEN-GERY HERITAGE S
A-04 NEW VINYL WALL SIGNAGE
A-05 PAINT EXISTING BRICK WALL, WHITE
A-06 NEW 1/2" PVC WALL SIGNAGE ON 22ND ST
A-07 NEW ALUMINUM AWNING - 39' ON 22ND ST
A-08 NEW LIGHTING INSTALLED ON UNDERSIDE OF AWNING - 4 FIXTURES
A-09 CLEAN AND REPAIR BRICK ON 2ND AND 3RD STORIES
A-10 INSTALL NEW RESIDENTIAL SECURITY GATE
A-11 EXISTING ALUMINUM STOREFRONT GLAZING TO REMAIN. PAINT FRAME BLACK
A-12 PAINT EXISTING SILLS, WHITE
A-13 PREP & PAINT EXISTING OH ROLLING GATE, BLACK
A-14 BACK FILL AND SUPPORT NEW CONCRETE SIDEWALK. SEE STRUCTURE FOR REINFORCEMENT DETAILS.
RECOMMENDED DUE TO UNSAFE SIDEWALK CONDITION.
A-15 NEW BRICK PILASTER
A-16 NEW BRICK SILL
A-17 NEW BRICK BASE
A-18 ALIGN NEW BRICK VENEER TO END OF EXISTING COLUMN
PHOTO: EXISTING RENDERING : PROPOSED - BASE SCOPE
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
GENERAL NOTES:
ALL DRAWINGS ARE TO SCALE AS INDICATED. THE CONTRACTOR MUST
VERIFY THE SCALE BEFORE BEGINNING CONSTRUCTION. DO NOT SCALE
DIRECTLY FROM THE DRAWINGS.
IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN ALL
PERMITS FOR PLUMBING AND ELECTRICAL WORK, AND ANY OTHER WORK
NOT PERMITTED UNDER A GENERAL BUILDING PERMIT.
WORK NOT INDICATED ON A PART OF THE DRAWINGS BUT REASONABLY
IMPLIED TO BE SIMILAR TO THAT SHOWN AT CORRESPONDING PLACES,
SHALL BE REPEATED.
CONTRACTOR SHALL COORDINATE OPENINGS SHOWN ON THE DRAWINGS.
CONTRACTOR SHALL VERIFY AND/OR ESTABLISH ALL EXISTING CONDITIONS
AND DIMENSIONS AT THE SITE.
IF THE EXISTING FIELD CONDITIONS DO NOT PERMIT THE INSTALLATION OF
THE WORK IN ACCORDANCE WITH THE DETAILS SHOWN, THE CONTRACTOR
SHALL NOTIFY THE ARCHITECT IMMEDIATELY AND PROVIDE A SKETCH OF
THE CONDITION WITH CONTRACTOR’S PROPOSED MODIFICATION OF THE
DETAILS GIVEN ON THE CONTRACT DOCUMENTS.
IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND ALL
SUB-CONTRACTORSTO COORDINATE THE WORK AND VERIFY ALL
DIMENSIONS AND INSPECT CONDITIONS OF PRIOR WORK BY ALL TRADES
BEFORE PROCEEDING WITH ANY WORK. UNACCEPTABLE OR INCORRECT
PRIOR WORK SHALL BE REPAIRED OR REPLACED BEFORE STARTING WORK.
PROCEEDING WITH THE WORK SHALL CONSTITUTE ACCEPTANCE OF PRIOR
WORK.
WHERE WORK INVOLVES EXISTING SUPPORTING STRUCTURE, THE
CONTRACTOR SHALL PROVIDE SHORING AND PROTECTION REQUIRED TO
INSURE THE STRUCTURAL INTEGRITY OF THE EXISTING STRUCTURE.
UNLESS SPECIFICALLY SHOWN OR NOTED ON THE DRAWINGS, NO
STRUCTURAL MEMBER SHALL BE CUT, NOTCHED, BORED OR OTHERWISE
MODIFIED WITHOUT THE PERMISSION OF THE STRUCTURAL ENGINEER OF
RECORD
ALL PRODUCTS AND MATERIALS TO BE INSTALLED FOLLOWING
MANUFACTURERS' RECOMMENDATIONS.
CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES IN
THE DOCUMENTS PRIOR TO PROCEEDING WITH ANY WORK INVOLVED.
THE PURPOSE OF THESE DRAWINGS IS FOR THE CONTRACTOR TO INCLUDE
ALL THE LABOR, MATERIALS AND SERVICES REQUIRED FOR THE
COMPLETION OF ALL WORK SHOWN OR REASONABLY IMPLIED BUT NOT
LIMITED TO THAT EXPLICITLY SHOWN IN THE DOCUMENTS.
1.
2.
3.
4.
5.
PROJECT NOTES:
"BASE SCOPE" MEANS THE MINIMUM SCOPE OF WORK. ADDITIONAL SCOPE
MAY BE REQUIRED TO COMPLY WITH CODE, LIFE SAFETY AND STRUCTURAL
REQUIREMENTS.
"AD-ALT SCOPE" MEANS ADDITIONAL AND ALTERNATIVE SCOPE. THE
OWNER HAS THE RIGHT TO INCLUDE OR EXCLUDE ANY OR ALL ITEMS
IDENTIFIED IN THE FINAL SCOPE OF WORK
PAINTING APPLIES TO FIRST LEVEL ONLY UNLESS NOTED OTHERWISE
FOR NEW OR REPLACEMENT GATES, INSTALL SEE-THROUGH GRILLES ONLY
WINDOW DECALS TO HAVE CLEAR BACKGROUNDS RATHER AN OPAQUE
PANELS OR FULL-WINDOW COVERING, TYP.
RENDERING: PROPOSED - FULL SCOPE
EXISTING PAINTED BRICK
DA-01
DA-05
DA-06
DA-07
DA-07
DA-09
EXISTING OH ROLLING GATE
EXISTING PAINTED BRICK
DA-03
DA-02
DB-01DB-01
DRAWN BY:
SCALE:
N O
T
FO
R C
O N
ST
R
UC
TI
O N
PROJECT:
SWRL STUDIO, LLC
2715 Folsom St Philadelphia, PA 19130
©2026
DATE:
PROJECT NO:
NOTES:
swrl studio
NO. DATE DESCRIPTION
ARCHITECT
STRUCTURAL ENGINEER
PRESTON STRUCTURAL SOLUTIONS, LLC
106 Gay Street, Unit 305 Philadelphia, PA 19127
1/4" = 1'-0"
A101
FC
EXTERIOR
ELEVATIONS
2163 RIDGE
KORMAN'S
2163 RIDGE AVE
PHILADELPHIA, PA 19121
10/24/26 2026_02
SCALE: 1/4" = 1'-0"
1 ELEVATION - 22ND ST - DEMO
SCALE: 1/4" = 1'-0"
2 ELEVATION - NICHOLAS ST - DEMO
SCALE: 1/4" = 1'-0"
3 ELEVATION - RIDGE AVE - DEMO
AD-ALT SCOPE - DEMO
DA-01 REMOVE EXISTING ANGLED WALL SIGN TO REVEAL METAL CORNICE ON 22ND ST
DA-02 REMOVE BROKEN LIGHT UP SIGN. PATCH AND REPAIR WALL AS NECESSARY
DA-03 REMOVE EXISTING RESIDENTIAL COLLAPSIBLE GATE
DA-05 REMOVE EXISTING WALL SLATS
DA-06 REMOVE EXISTING OVERHEAD ROLLING DOORS ON 22ND ST
DA-07 REMOVE EXISTING INFILL WALL
DA-09 REMOVE EXISTING CELLAR DOORS
BASE SCOPE - DEMO
DB-01 REMOVE EXISTING ANGLED WALL SIGN TO REVEAL METAL CORNICE ON RIDGE AVE
18" 84" 18" 84" 18" 84" 18" 84" 18"
35' - 6"27' - 6 1/16" V.I.F.
/2 " V
.I.
F.
A103
8"
V.I.F.
1' - 1 11/16"
A-05
A-01
A-06
A-07
A-02
A-03
A-04
A-08
A-09
A-14
A-15
A-16
A-17
A-18
29' - 10" V.I.F.
/2 " V
.I.
F.
A-01
A-12
A-05
A-13
A103
A-01
B-01B-01
B-03B-03
B-05B-05
B-04B-04
B-02B-02
A-10
A-11
A-09
6.6 sf
10.9 sf
12.9 sf
5.5 sf 5.4 sf 5.5 sf
15.8 sf 15.8 sf 15.8 sf
.7 sf
1.2 sf
WINDOW SIGNAGE ALLOWANCE
PER PHILADELPHIA CODE 14-904
GLASS AREA 6.6+10.9+12.9+5.5+5.4+5.5+15.8+15.8+15.8 = 94.2 SF
MAX. SIGNAGE AREA (20%) 18.8 SF
PROPOSED SIGNAGE AREA 1.2+.7 = 1.9 SF - IN COMPLIANCE
DRAWN BY:
SCALE:
N O
T
FO
R C
O N
ST
R
UC
TI
O N
PROJECT:
SWRL STUDIO, LLC
2715 Folsom St Philadelphia, PA 19130
©2026
DATE:
PROJECT NO:
NOTES:
swrl studio
NO. DATE DESCRIPTION
ARCHITECT
STRUCTURAL ENGINEER
PRESTON STRUCTURAL SOLUTIONS, LLC
106 Gay Street, Unit 305 Philadelphia, PA 19127
1/4" = 1'-0"
A102
FC
EXTERIOR
ELEVATIONS -
PROPOSED
2163 RIDGE
KORMAN'S
2163 RIDGE AVE
PHILADELPHIA, PA 19121
10/24/26 2026_02
SCALE: 1/4" = 1'-0"
1 ELEVATION - 22ND - PROPOSED
SCALE: 1/4" = 1'-0"
2 ELEVATION - NICHOLAS ST - PROPOSED
SCALE: 1/4" = 1'-0"
3 ELEVATION - RIDGE AVE - PROPOSED
BASE SCOPE - PROPOSED
B-01 NEW 1/2" PVC WALL SIGNAGE ON RIDGE AVE
B-02 PREP & PAINT EXISTING OH ROLLING GATE. INSPECT FOR PROPER FUNCTION
B-03 NEW ALUMINUM AWNING TO COVER OH ROLLING GATE - 18' ON RIDGE AVE
B-04 NEW LIGHTING INSTALLED ON UNDERSIDE OF AWNING - 4 FIXTURES
B-05 NEW VINYL WINDOW SIGNAGE
AD-ALT SCOPE - PROPOSED
A-01 PATCH AND REPAIR EXISTING METAL CORNICE. PROVIDE NEW ROOFING AND FLASHING
A-02 NEW INFILL WALL: METAL FRAMING, INSULATION, INTERIOR DRYWALL, EXTERIOR CEMENT BOARD PANELING
A-03 NEW THIN BRICK VENEER. BOD: GLEN-GERY HERITAGE S
A-04 NEW VINYL WALL SIGNAGE
A-05 PAINT EXISTING BRICK WALL, WHITE
A-06 NEW 1/2" PVC WALL SIGNAGE ON 22ND ST
A-07 NEW ALUMINUM AWNING - 39' ON 22ND ST
A-08 NEW LIGHTING INSTALLED ON UNDERSIDE OF AWNING - 4 FIXTURES
A-09 CLEAN AND REPAIR BRICK ON 2ND AND 3RD STORIES
A-10 INSTALL NEW RESIDENTIAL SECURITY GATE
A-11 EXISTING ALUMINUM STOREFRONT GLAZING TO REMAIN. PAINT FRAME BLACK
A-12 PAINT EXISTING SILLS, WHITE
A-13 PREP & PAINT EXISTING OH ROLLING GATE, BLACK
A-14 BACK FILL AND SUPPORT NEW CONCRETE SIDEWALK. SEE STRUCTURE FOR REINFORCEMENT DETAILS.
RECOMMENDED DUE TO UNSAFE SIDEWALK CONDITION.
A-15 NEW BRICK PILASTER
A-16 NEW BRICK SILL
A-17 NEW BRICK BASE
A-18 ALIGN NEW BRICK VENEER TO END OF EXISTING COLUMN
VIF
36' - 9 3/4"
NEW 1/2" PVC LETTERING ON PAN
ALUMINUM AWNING
8"
3"
NEW 1/2" PVC LETTERING ON PAN
ALUMINUM AWNING
VIF
18' - 0"
VINYL ADDRESS SIGN
SIDEWALK
35' - 6"
18" 84" 18" 84" 18" 84" 18" 84" 18"
SI
DE
W
AL
K
SI
D
EW
AL
K
A103
22ND STREET
RI
DG
E
AV
E
62 1/8" 106" 106" 106"21
/1 6"
W
ID
TH
O
F
AW
NI
NG
1" V
IF
WIDTH OF AWNING
38' - 6" VIF
42"
LINE OF AWNING OVERHEAD
A-14 A-14
5/8" GYP
TRIM, PROFILE TBD
6" METAL STUD @ 16" O.C.
R-21 MIN. INSULATION
ZIP SHEATHING
FIBER CEMENT PANELING. BOD: HARDIE PANEL HZ5
TRIM, PROFILE TBD
THIN BRICK
EXTERIORINTERIOR
A103
EXISTING SIDEWALK
A103
Z-CLIP ANCHOR, SEE STRUCTURE
8"
1 1/4"
42"
1" ALUMINUM TUBE
METAL AWNING, BLACK
POWDER COATING
Z-CLIP ANCHOR, SEE STRUCTURE
RECESSED BAFFLE LIGHT
NEW 1/2" PVC LETTERING
NEW 2" ALUMINUM SIGNAGE PAN
FIBER CEMENT PANEL. BOD: HARDIE PANEL HZ5
1/4" RAIN SCREEN DRAINAGE MAT
ZIP SHEATHING, SEAMS TAPED AND ROLLED
R-21 MIN INSULATION
CONCRETE CURB TO REPLACE
BROWNSTONE CURB
EXISTING FOUNDATION WALL
EXISTING FLOOR ASSEMBLY
TO REMAIN TRIM PROFILE, TBD, DO NOT CAULK
5/8" TYPE X GYP
THIN BRICK VENEER
EXISTING SIDE WALK
SCALE: 1/2" = 1'-0"
2 PROPOSED AWNING - RIDGE AVE
SCALE: 1/2" = 1'-0"
1 PROPOSED AWNING - 22ND STREET
DRAWN BY:
SCALE:
N O
T
FO
R C
O N
ST
R
UC
TI
O N
PROJECT:
SWRL STUDIO, LLC
2715 Folsom St Philadelphia, PA 19130
©2026
DATE:
PROJECT NO:
NOTES:
swrl studio
NO. DATE DESCRIPTION
ARCHITECT
STRUCTURAL ENGINEER
PRESTON STRUCTURAL SOLUTIONS, LLC
106 Gay Street, Unit 305 Philadelphia, PA 19127
As indicated
A103
FC
PLANS AND
ENLARGED
DRAWINGS
2163 RIDGE
KORMAN'S
2163 RIDGE AVE
PHILADELPHIA, PA 19121
10/24/26 2026_02
SCALE: 1/4" = 1'-0"
3 PROPOSED FLOOR PLAN / RCP
SCALE: 1/2" = 1'-0"
4 WALL SECTION
SCALE: 1 1/2" = 1'-0"
5 AWNING DETAILS
SCALE: 1 1/2" = 1'-0"
6 DETAIL INFILL WALL BASE
A.B. ANCHOR BOLT
A.F.F. ABOVE FINISH FLOOR
ADDL. ADDITIONAL
ALT. ALTERNATE
ARCH. ARCHITECT
B.C.E. BOTTOM CHORD EXTENSION
B.O. BOTTOM OF
BLDG. BUILDING
BM. BEAM
BOTT. BOTTOM
BRG. BEARING
BSMT. BASEMENT
BTWN. BETWEEN
CL CENTERLINE
CANT. CANTILEVER
CMU CONCRETE MASONRY UNIT
COL. COLUMN
CONC. CONCRETE
CONN. CONNECTION
CONT. CONTINUOUS
CTRD. CENTERED
Ø DIAMETER
DWG. DRAWING
E.F. EACH FACE
E.O.D. EDGE OF DECK
E.O.S. EDGE OF SLAB
E.W. EACH WAY
EA. EACH
EL. ELEVATION
ELEV. ELEVATOR
EMBED. EMBEDMENT
EQ. EQUAL
EQUIP. EQUIPMENT
EWB EACH WAY BOTTOM
EX. EXISTING
EXIST. EXISTING
EXP. EXPANSION
EXT. EXTERIOR
FDN. FOUNDATION
FIN. FINISH
FLR. FLOOR
FT. FEET
FTG. FOOTING
GA. GAGE
GALV. GALVANIZED
H.P. HIGH POINT
HORIZ. HORIZONTAL
I.F. INSIDE FACE
IN. INCHES
INFO. INFORMATION
INT. INTERIOR
JT. JOINT
EWT EACH WAY TOP
BP_ BEARING PLATE
GB_ GRADE BEAM
k KIP k-ft KIP-FEET
L.P. LOW POINT
L.W. LIGHT WEIGHT
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LWB LONG WAY BOTTOM
M.E.P. MECHANICAL ELECTRICAL PLUMBING
M.S.T. METAL STUD TRUSS
MAX. MAXIMUM
MECH. MECHANICAL
MEZZ. MEZZANINE
MFR. MANUFACTURER
MIN. MINIMUM
MISC. MISCELLANEOUS
N.T.S. NOT TO SCALE
N.W. NORMAL WEIGHT
o/c ON CENTER
PL PLATE
PC PILE CAP
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PTN. PARTITION
REINF. REINFORCEMENT
REQ'D. REQUIRED
RET'G. RETAINING
S.F. STEP FOOTING
S.O.G. SLAB ON GRADE
SCHED. SCHEDULE
SECT. SECTION
SIM. SIMILAR
SPECS. SPECIFICATIONS
STIFF. STIFFENER
STRUCT. STRUCTURAL
SWB SHORT WAY BOTTOM
T&B TOP AND BOTTOM
T. TOP
T.O. TOP OF
T.O.C. TOP OF CONCRETE
T.O.S. TOP OF STEEL
T.S. THICKENED SLAB
TCELE TOP CHORD EXTENSION LEFT END
TCERE TOP CHORD EXTENSION RIGHT END
TDS TURN DOWN SLAB
THK. THICK OR THICKENED
TYP. TYPICAL
U.N.O. UNLESS NOTED OTHERWISE
V.I.F. VERIFY IN FIELD
VERT. VERTICAL
W.R.T. WOOD ROOF TRUSS
w/ WITH
WWF WELDED WIRE FABRIC
P.C. PRECAST
P.A.F. POWDER ACTUATED FASTENER
M.P. MASONRY PIER
N.B.L. NON BEARING LINTEL
W.P. WALL PLATE
W.C. WET COLUMN
ABBREVIATIONS
PROJECT DESCRIPTION
1. Project consists of a facade improvment to an existing mixed use building. Existing superstructure is
3 levels above grade and 1 level below grade. Foundations consist of CMU and stone foundation walls. Superstructure is wood floor sheathing over rough sawn wood framing.
2. This description is for general orientation only. The General Contractor is responsible for all scope items described in the drawings and project specifications as well as for all material and labor that can reasonably be inferred there from.
GENERAL APPLICATION
1. These structural drawings are intended to be used in conjunction with the project’s architectural, mechanical, and electrical drawings. All disciplines must be reviewed collectively to fully understand the design intent and construction requirements.
2. Contractors shall not bid or proceed with any portion of the work without thoroughly reviewing all relevant project documents, including but not limited to architectural, mechanical, and electrical drawings and specifications.
3. Any perceived discrepancies, omissions, or ambiguities in the structural drawings shall be promptly brought to the attention of the Structural Engineer. No related work shall proceed until the Engineer has issued written clarification or direction.
4. The Contractor is responsible for notifying the Structural Engineer in writing of any proposed deviation or substitution from the contract documents. Approval or review of shop drawings, product data, or similar submittals by the Structural Engineer shall not constitute acceptance of deviations unless such deviations have been clearly and explicitly identified in writing at the time of submission.
MISCELLANEOUS NOTES
1. The Contractor is solely responsible for implementing and maintaining all safety measures, programs, and precautions associated with the execution of the work on this project.
2. The Contractor shall protect all persons and property, both on-site and adjacent to the project site, from injury, damage, or loss. Responsibility for such protection lies exclusively with the Contractor.
3. The selection and execution of construction means, methods, techniques, sequences, and procedures—including the erection of structural elements—are entirely the responsibility of the Contractor.
4. The structure is engineered to perform as a complete system only upon full completion and under the design loads specified. The Contractor is responsible for ensuring construction-phase stability, including evaluating the structure’s capacity to support construction loads. Provide all temporary bracing, shoring, and other measures required to maintain stability and safety during construction.
5. No openings or modifications to structural elements—including changes in size, shape, or location— shall be made without prior written approval from the Structural Engineer.
6. Openings measuring 1'-4" or less on a side are typically not shown on the structural drawings. Refer to the drawings of other design disciplines for the locations and dimensions of such openings.
7. Openings in floors and roofs for utility penetrations are not detailed on structural drawings. The Contractor shall coordinate the required locations and dimensions with the respective trade responsible for the utility work.
8. All proposed openings in structural members shall be clearly indicated on shop drawings and submitted for review. Any opening not shown on the structural drawings is subject to written acceptance and shall not be implemented without prior approval.
9. Fireproofing requirements for structural components are not depicted on these drawings. Refer to project specifications and architectural documents for fireproofing locations and requirements.
10. Do not scale these drawings. Use only the dimensions shown. In the event of discrepancies or conflicts, obtain clarification from the Architect and Structural Engineer before proceeding with affected work.
11. No structural repairs, alterations, or modifications shall be undertaken without prior review and written approval from the Structural Engineer. All proposed modifications must be supported by detailed drawings and structural calculations prepared by a licensed Professional Engineer registered in the state where the project is located and retained by the Contractor.
12. If framed floors are used for staging or temporary material storage, the Contractor shall verify that the applied unit loads do not exceed the design loads of the floor framing system.
QUALITY ASSURANCE AND QUALITY CONTROL
1. The Contractor is solely responsible for ensuring the quality of all workmanship and materials, including those provided by subcontractors and suppliers.
2. Testing or inspections performed by or on behalf of the Owner do not relieve the Contractor of the obligation to perform all work in full compliance with the Contract Documents.
3. Workmanship: The Contractor shall correct, at their own expense, any work that fails to meet specified requirements.
4. All deficient work shall be corrected using methods acceptable to the Architect. Any additional costs incurred by the Architect in reviewing or approving corrective work shall be the responsibility of the Contractor.
5. Testing and special inspections required by the structural drawings, applicable building code, and the local authority having jurisdiction shall be performed by the Owner’s Testing Agency. The agency must comply with ASTM E329 and shall, upon completion of the work, provide a certificate of compliance signed by a Professional Engineer licensed in the state where the project is located, and responsible for the special inspections and testing.
6. The individual overseeing soils and foundation testing on behalf of the Testing Agency shall be a licensed Professional Engineer specializing in geotechnical engineering, herein referred to as the Geotechnical Engineer. This individual is responsible for verifying that soils, earthwork, and foundations conform to the foundation design and the referenced geotechnical report. Refer to the “Foundations” section of these General Notes for further requirements.
7. Refer to the “Special Inspections” section of these General Notes for a detailed list of required inspections and testing.
SPECIAL INSPECTION
1. Special inspections and testing shall be performed in accordance with the requirements of the applicable building code, the local authority having jurisdiction, and the construction documents.
Refer to the “Quality Assurance” section of these General Notes for additional guidance.
2. The Contractor shall coordinate and schedule all required inspections and testing in advance of commencing work subject to such requirements. Reasonable notice must be provided to the Special Inspector to facilitate timely performance.
3. Any deficiencies identified during inspections or testing shall be corrected to the satisfaction of the Testing Agency before acceptance of the work.
4. Inspections conducted by local code officials do not substitute for the inspections and testing required to be performed by the Owner’s Testing Agency, as stipulated in the construction documents.
SPECIFICATIONS
1. These General Notes are intended to function as the structural portion of project specifications.
SUBMITTALS
1. Refer to the “Materials” section of these General Notes for a list of items requiring shop drawing submittals.
2. Submit all required documentation (e.g., manufacturer’s product data, shop drawings, etc.) in electronic format (PDF or equivalent).
3. Reproducible copies of the contract documents shall not be used as the basis for shop drawings or submittals.
4. All submittals shall be transmitted directly to Preston Structural Solutions LLC for review and further distribution.
5. Prior to submission, submittals must be reviewed by both the Contractor and applicable
Subcontractors. Each drawing shall bear the Contractor’s approval stamp, confirming coordination of dimensions, quantities, and interface with other trades in accordance with the contract documents.
6. Allow a minimum of 14 calendar days for the review process following receipt of complete submittal packages.
7. Reviewed submittals will be returned to the Contractor with comments, if any, by Preston Structural Solutions LLC in electronic format.
CAST-IN-PLACE CONCRETE
GENERAL:
1. All concrete work shall conform to ACI 318 and ACI 301. Dimensional tolerances shall conform to ACI
117 unless noted otherwise. The Contractor shall maintain copies of these standards on site at all times.
2. Required concrete compressive strengths are specified in the "Concrete Mix Design Requirements" table.
3. Refer to the "Concrete Materials Designation" table for specific material requirements.
FORMING:
1. All formwork shall provide a Class B finish per ACI 117 unless noted otherwise on the architectural drawings. For architectural concrete finishes, refer to the architectural documents.
2. Construction joints indicated on the drawings shall be incorporated into the work. Elimination or modification of joint locations shall require approval by the Structural Engineer. Additional joints, if necessary, shall be placed at locations of minimum shear and included in shop drawings for review.
Vertical joints in beams, girders, joists, walls, and slabs shall be located at mid-span unless otherwise noted and shall include keys and dowels to transfer design shear. Reinforcement shall pass continuously through joints. Where roughened surfaces are required, mechanically roughen to a ¼" amplitude and ensure all laitance is removed.
3. Provide chamfers at exposed corners of columns, beams, walls, and slab edges unless otherwise indicated in architectural drawings.
4. Coordinate all openings (e.g., doors, windows, MEP penetrations, drip slots, reglets, brick ledges, curbs) with architectural drawings. Structural drawings may not indicate all opening dimensions.
5. Formwork removal shall conform to ACI 301.
REINFORCING AND EMBEDDED ITEMS:
1. Provide standard hooks at bar terminations at all exposed concrete faces unless otherwise indicated (e.g., at openings, slab edges, joints, beam ends, wall ends).
2. Provide two (2) #5 bars on each side of all slab and wall openings unless noted otherwise. Extend bars a minimum of 2'-0" beyond each edge of the opening.
3. Welded wire fabric (WWF) shall be lapped one full mesh plus 2 inches.
4. Reinforcing bar lap splices shall be a minimum of 64 bar diameters unless otherwise specified.
5. Reinforcing dowels shall be embedded a minimum of 21 bar diameters.
6. Provide continuous reinforcing through corners, construction joints, contraction/control joints, and at all interfaces between abutting concrete elements. Epoxy-coated bars shall be used through construction joints at parking garage slabs and other slabs exposed to de-icing agents.
7. Welding of reinforcement is prohibited unless specifically permitted and shall comply with ASTM A706.
PLACING AND FINISHING:
1. All handling, placement, construction, and curing of concrete shall comply with ACI 301, including procedures for cold, hot, or wet weather conditions.
2. Curing compounds shall not be used on surfaces intended to receive subsequent finishes (e.g., additional concrete, tile, paint) unless the curing compound can be shown to be removable, dissipative, or otherwise compatible with subsequent applications.
3. All concrete shall be cast-in-place unless specifically approved otherwise. Shotcrete placement is not permitted unless approved in writing by the Structural Engineer prior to permit submission.
Shotcrete requests shall comply with ACI 506.2 and include preconstruction testing. Shotcrete may only be used for simple, conventionally reinforced foundation walls. All pilasters and in-wall columns must be cast separately and not formed as part of the shotcrete work.
COMMON NAIL DIMENSIONS
Common Nail (Steel Wire) Minimum Length (in)
6d
0.131
0.148
2 1/2
3 1/20.162
Minimum Diameter (in)
8d
10d
16d
0.113
CONCRETE MATERIALS DESIGNATION
Material Standard
Portland Cement ASTM C150, Type I or Type II
Fly Ash ASTM C618, C or F
Aggregate ASTM C33
Water Potable
High Range Water Reducing Admixture
ASTM C494, Type A or Type D
Accelerator Admixture ASTM C494, Type C or Type E
Water Reducing Admixture
ASTM C494, Type F or Type G
Air Entraining Admixture ASTM C260
Curing Compound ASTM C306, Type I, Class A
Reinforcing Bars ASTM A615-grade 60 (Specified Yield Strength = 60ksi)
Vapor Retarder below SOG ASTM E1745-Class A
Welded Reinforcing Bars ASTM A706-grade 60 (Specified Yield Strength = 60ksi)
Notes:
1. Type III Portland cement may be used if acceptable to the Architect.
CONCRETE MIX DESIGN REQUIREMENTS
Exterior Slab-on-Grade (S.O.G.)
Element f'c (psi)
5000, NW
Cement Type
I/II
Max W/C
0.4
Max Agg
3/4"
Air Content (Note 1,2)
Slump (Note 3)
4"
Exposure Class
F1 C2
S0 W0
TABLE FOOTNOTES:
1. For any concrete exposed to freezing temperatures and moisture, the air content shall be the greater of 5% minimum required by ACI 318, or of that shown in the table.
2. Tolerance on air content as delivered shall be +/- 1.5%
3. Slump tolerances as follow (ACI 117):
Specified Slump not greater than 4" = +/- 1" Specified Slump more than 4" = +/- 1 1/2" Where Slump is specified as a range = No Tolerance See ACI 301 for slump of concrete before addition of plasticizers or high-range water reducing admixtures.
GENERAL CONCRETE MIX NOTES:
1. Strength (f'c) is the 28 day compressive strength at 28 days unless noted otherwise or compressive strength at the specified age.
2. Concrete is normal weight concrete unless noted otherwise. Normal weight concrete (NW) shall have a dry density of 145 +/- 5 pcf unless noted otherwise. Lightweight concrete (LW) shall have a dry density of 110 +/- 5 pcf unless noted otherwise.
3. Required minimum average splitting tensile strength = 6.7x√(f'c) regardless of concrete density.
4. Mix designs shall be in accordance with ACI 301.
5. Exposure Class indicates the severity of the anticipated exposure of concrete members for each exposure indicated below according to ACI 318/ACI 301:
Freeze Thaw Exposure noted thus: F0,F1,F2,F3 Water-Soluble Sulfate in Soil Exposure noted thus: S0,S1,S2,S3 Permeability Requirements noted thus: W0,W1 Corrosion Protections of Reinforcement noted thus: C0,C1,C2 Refer to ACI 301/ACI 318 for specific requirements based on the exposure category indicated in the mix design table above.
6. Corrosion Protection of Reinforcement requirements (C0,C1,C2):
Maximum water-soluble chloride ion (CL-) content in concrete, by % weight of cement:
C0 = 1.0 C1 = 0.3 C2 = 0.15
7. Where concrete is exposed to F3 freeze thaw exposure, restrictions on maximum fly ash and/or other cementitious materials apply. Refer to Table 26.4.2.2(b) in ACI 318-14 for requirements.
Footings 4000, NW I/II - 3/4" - 4"
F0 C0
S0 W0
Foundation Walls 4000, NW
I/II 0.45 3/4" 5 4"
F1 C2
S0 W0
DESIGN VALUES FOR DIMENSIONAL LUMBER
Species & Grade Compressive Stress
Select Structural
Flexural Stress
1,400 psi
No. 1
No. 2
Stud
975 psi
850 psi
675 psi
1,500 psi
1,350 psi
1,300 psi
800 psi
Horizontal Shear Stress
150 psi
150 psi
150 psi
150 psi
Modulus of Elasticity
1,600 ksi
1,500 ksi
1,300 ksi
1,200 ksi
HEM-FIR (HF)
FOUNDATIONS
1. No Geotechnical Engineering report has been provided. Foundations have been designed in accordance with the design parameters referenced in the “Structural Design Criteria” section. All earthwork and subgrade preparation shall be performed to achieve soil properties consistent with those design criteria. The contractor shall evaluation the soils to determine if the design parameters utilized are appropriate and engage a Geotechnical Engineer as necessary.
2. The Geotechnical Engineer shall perform inspection and testing of subgrade soils, earthwork, and foundation conditions. Refer to the “Special Inspections” and “Quality Assurance” sections of these General Notes. Do not place foundations or slabs-on-grade without written approval from the Geotechnical Engineer confirming that site preparation and soil conditions conform to the foundation design requirements.
3. The bottoms of exterior footings shall be founded below final exterior grade as required to satisfy frost protection requirements. Refer to the “Structural Design Criteria” section for frost depth and bearing requirements.
4. Where foundation walls retain earth on both sides, backfill shall be placed and compacted simultaneously on both sides to maintain balanced lateral soil pressure.
5. All foundation walls shall be adequately braced against movement during backfilling operations.
Bracing shall remain in place until both the lower and upper slabs are installed. Additional bracing shall be provided as needed to resist movement or overstress from construction loading, irrespective of the slab installation sequence.
6. Vertical movement of slab-on-grade is anticipated. Refer to the Geotechnical Report for estimated movement values. Interior non-load-bearing partitions shall be isolated from the slab-on-grade to accommodate potential vertical movement.
7. The Contractor shall provide and maintain continuous site drainage—via mechanical or other suitable means—as required to control surface water and subsurface moisture, ensuring a dry and stable work area throughout construction.
8. Foundation drainage systems, waterproofing, and associated detailing are not shown in the structural drawings. Refer to the architectural and civil drawings and project specifications for all requirements related to waterproofing, drainage, and coordination with other disciplines.
REQUIRED CONCRETE COVER
Assembly Cover (in)
Concrete cast against & permanently exposed to earth
Concrete Exposed to Earth or Weather
#6 - #18
#5 and smaller
1 1/2
3/4
1 1/2
Concrete not Exposed to Earth or Weather
Walls, Slabs #11 and smaller
Columns and beams
Building Code: 2021 International Building Code (Note 1)
Structural Design Criteria
Local Jurisdiction: Philadelphia, PA Risk Category: II
Foundations:
Notes:
1. The governing building code defines the applicable edition of referenced codes and standards. Where governing building code does not define referenced codes and standards, the latest edition shall be used.
2. Foundation design criteria determined utilizing 2021 IBC minimum bearing capacity tables. Contractor shall verify in-situ soils reflect the provided bearing capacity.
Wind Loading Basic Wind Speed Exposure Category
Vult= 114 MPH B
Seismic Loading Seismic Importance Factor, Ie 1.00 Mapped Spectral Response Acceleration Ss 0.181 S1 0.047 Site Class D Spectral Response Coefficients Sds 0.193 Sd1 0.076 Snow Loading Ground Snow Load, Pg 25 PSF Minimum Flat Roof Snow Load, Pf 21 PSF
Allowable Bearing Capacity 2,000 PSF Minimum Frost Depth 36 IN
GCpi +/-0.18 Ultimate Components & Cladding Wind Design Pressure, PSF 20ft2 50ft2 100ft2
Wall Pressures
-22.2/20.4 -21.0/19.2 -20.0/18.2Interior (Zone 4) -26.6/20.4 -24.1/19.2 -22.2/18.2Corner (Zone 5)
Importance Factor, IS 1.0
WOOD FRAMING
GENERAL:
1. All wood construction shall conform to ANSI/AWC NDS unless otherwise noted. A current copy of this standard shall be maintained on-site by the Contractor at all times.
2. Refer to the “Wood Materials Tables” for specified material types and properties.
3. Qualifications: All carpentry work shall be performed by tradespeople experienced with projects of comparable size and complexity and familiar with conventional light-frame construction and the minimum fastening requirements of the IBC.
PRODUCTS:
1. All wood framing shall be at a moisture content of 19% or less and shall be marked S-Dry (surface dried) or KD (kiln dried).
2. Unless noted otherwise, all sizes noted on these drawings are nominal. Actual sizes are based on
"Minimum Dressed-Dry" dimensions according to American Softwood and Lumber Standard PS20-10.
Members which the architect, engineer, or inspector judge to be misgraded shall be reinspected by a qualified lumber grader. Members which have permissible grade characteristics in such combination to affect the performance of the member are also subject to replacement at the discretion of the architect, engineer, or inspector.
3. Unless noted otherwise, all manufactured framing sizes are based on specified manufacturers published information.
4. See plan notes for wall framing material and spacing.
5. Wood I-joists: where framing members are noted TJI on the drawings, use engineered products by
Weyerhaeuser or approved equal.
6. Structural Panels: Sheathing for roofs and walls shall conform to APA PS-2 standards. All panels shall be Exposure 1, unless noted otherwise.
7. Sills: Sill plates shall be pressure treated Southern Pine stamped to show compliance with AWPA standards.
8. Wood stud wall framing elements including but not limited to headers, top plates, sole plates, cripple studs, trimmers, and sills shall match stud member specification, unless noted otherwise.
CONNECTORS:
1. All connectors, anchors, bolts, and fasteners in contact with preservative-treated wood shall be either hot-dipped galvanized (G90 or G185) or stainless steel (Type 304 or 316).
2. Provide anchor bolts at all foundation top surfaces to secure sill plates. See typical details for anchor size, spacing, and embedment.
3. J- and L-type anchor bolts are acceptable for sill plate anchorage.
4. Provide plate washers at all anchor bolt connections in shear walls. Refer to the “Typical Wood Shear
Wall” details for configuration.
5. All nailing shall meet or exceed the minimum requirements of IBC Table 2304.9.1 unless more stringent requirements are indicated in the drawings or notes.
6. Nails shall conform to ASTM F1667 and be steel common wire type.
7. Pre-drill nail holes where necessary to prevent splitting of wood members.
8. Steel plates used in wood construction shall conform to ASTM A36.
9. Bolts shall conform to ASTM A307.
10. Exposed bolts not in contact with treated wood may be plain, uncoated steel.
11. Bolt holes shall be 1/16" larger than the bolt diameter unless specified otherwise.
12. All bolts shall be retightened before enclosure or concealment.
13. Lag screws shall penetrate a minimum of 8 times the shaft diameter into the main member unless otherwise noted.
14. Diagonal (toe-nail) lag screws shall have a minimum edge distance of 4 times the shaft diameter.
INSTALLATION:
1. Built-up wood columns concealed within wall framing may be constructed using multiple 2x members.
Do not splice individual laminations. Refer to typical details for required nailing.
2. At roof and floor levels, install wood panels with their long dimension perpendicular to supports and stagger short edges.
3. Refer to plan notes for nailing patterns at roof and floor sheathing.
4. Refer to the plans for locations requiring special blocking and additional fastening.
5. Refer to plan notes for vertical wall sheathing requirements.
6. For all designated shear walls, sheathing contributes to lateral resistance. Refer to typical details for required fastening of sheathing to framing members.
7. Provide solid blocking with flat 2x4s at all sheathing edges within shear walls.
FRAMING TOLERANCES:
1. Wall and partition layout: ±¼" from intended position.
2. Plates and runners: Deviation not to exceed ¼" in 8'-0" from a straight line.
3. Studs: Out-of-plumb tolerance of ¼" in 8'-0", not cumulative.
4. Face of framing: Deviation from true plane not to exceed ¼" in 8'-0".
WOOD STRUCTURAL PANEL REQUIREMENTS
Supporting Element Minimum Thickness
Roof over roof joists
24 OC Single Floor
32/16
15/32"
APA Span Rating
32/16
23/32"
15/32"
Floors (Sturd-I T&G)
Walls
REINFORCED MASONRY
GENERAL:
1. All masonry work shall conform to ACI 530.1/ASCE 6/ TMS 602 unless noted otherwise.
Contractor shall keep a copy of these references on site at all times.
2. Masonry Strength –See Masonry Strength Table
3. Materials –See Masonry Materials Table
TESTING:
1. Owner will engage a qualified Testing Agency, approved by the Architect and Engineer to perform tests and Special Inspections. Upon completion of work, Testing Agency shall furnish a certificate of compliance, signed by the Professional Engineer responsible for management of the Agency. The Professional Engineer must be registered in the state where the project is located. Tests and inspections shall be performed in compliance with ACI 530.1/ASCE 6/ TMS 602 and Chapter 17 of the IBC. Inspections include: proportions of site-prepared mortar, construction of mortar joints, location of reinforcement and connectors, grout space, grade and size of reinforcement, proportions of site-prepared grout, grout placement and curing.
Testing includes: Grout strength, mortar strength, and prisms.
2. Masonry grout shall not be placed until reinforcing and connectors have been inspected by the owner's independent inspection agency and/or the special inspector.
3. See "Special Inspections and Testing" Table.
SUBMITTALS:
1. Submittals shall conform to ACI 530.1/ASCE 6/ TMS 602. All submittals shall be reviewed by the Contractor prior to Engineers/Architects review and shall bear Contractors review stamp.
Contractor is responsible for reviewing submittals for conformance with all contract documents and coordination with all trades.
2. Submittals for all masonry shall include: Mix designs for grout and mortar, material certificates for: reinforcing, anchors, ties, and metal accessories, masonry units, mortar materials, and grout materials.
3. Reinforcing shop drawings shall include placement drawings 1/8"=1'-0”minimum scale complete with wall elevations. Include special reinforcement required at openings through masonry structure. Include all accessories specified and required to support reinforcement.
4. Embed shop drawings shall include placement drawings 1/8”=1’-0”minimum scale locating all embed plates, anchors, and anchor bolts for structural and non-structural components attaching to masonry. Contractor is responsible for coordinating with all trades for determining the need for embeds and locations. Post installed anchors are not allowed unless approved by the structural engineer during the shop submittal process.
REINFORCING AND EMBEDDED ITEMS:
1. Vertical reinforcement shall extend the full height of the wall unless noted otherwise. Provide vertical reinforcement at all wall corners; end of walls; each side of openings and at each side of control and expansion joints.
2. Provide bond beams at sill lines, top and bottom edge of openings, top of walls, floor lines, and roof lines. Bond beams shall be continuous unless noted otherwise. See typical bond beam detail.
3. Continue reinforcing through construction joints and around corners unless noted otherwise.
Terminate horizontal reinforcement at control joints except keep bars continuous at floor lines, roof lines, lintels, and top and bottom of typical openings.
4. Provide standard hooks on bars terminating at a masonry face unless noted. i.e.: edges of openings, ends of walls, heads, jambs, control joints, etc.
5. Splice bars with contact laps per the reinforcing splice and development length table, unless noted otherwise.
6. Vertical reinforcement shall have a minimum clearance of 3/4" from masonry and shall be supported and fastened together to prevent displacement.
7. Horizontal joint reinforcing shall be lapped no less than 6" at all splices including corners and tees where no control joint is used.
8. Dowels from concrete shall be furnished and placed by the concrete contractor.
9. Welding of reinforcing is prohibited, unless noted otherwise and shall conform to ASTM A706.
MASONRY ERECTION:
1. Unless otherwise noted, lay masonry in running bond.
2. Unless noted provide control joints at 30 feet on center.
3. Coordinate blockouts, reveals, holes, openings, and built in items with all contract documents and trades.
4. Grout lift heights shall follow requirements of TMS 602 Sections 3.5C and 3.5D.
5. Grout cells solid at: reinforcing, bond beams, inserts, anchors, elevator guide rails, and 24" below and 12" to each side of steel beam bearing points.
6. Consolidate grout pours 12" or less in height by mechanical vibration or puddling not more than five minutes after grouting.
7. Consolidate grout pours exceeding 12" in height by mechanical vibration not more than five minutes after grouting, and reconsolidate after initial water loss and settlement has occurred.
8. Grout in masonry beams shall be vibrated as it is placed. Where full depth grouting is required, the grouting shall extend to the end of the horizontal reinforcement.
9. Hot weather construction refer to ACI 530.1 section 1.8D.
10. Cold weather construction refer to ACI 530.1 section 1.8C.
MASONRY MATERIALS TABLE
Material Standard
ASTM C 90Hollow Concrete Masonry Units
ASTM C 476Grout
ASTM C 270Mortar
ASTM A615-grade 60Reinforcing
ASTM A651Wire Reinforcing
NOTES:
1. Provide lightweight hollow concrete masonry units for general use. Provide normal weight or solid units where indicated.
2. Mortar for concrete masonry shall be type S at exterior walls and type N at interior walls.
3. Hydrated lime required in all mortar.
4. Wire joint reinforcing shall be ladder type.
MASONRY STRENGTH TABLE
Element Specified Compressive Strength
Clay Masonry f'm = 2500 psi f'g>=f'm (2000psi minimum) f'm = 2000 psi f'g = 1.0*f'm (2000 psi minimum)
Grout for Clay Masonry
Concrete Masonry
Grout for Concrete Masonry
MASONRY REINFORCING SPLICE LENGTHS
Bar Size Splice Length (in.)
#3 13
#4
#5
NOTES:
1. Laps in reinforcing bars in reinforced masonry shall have minimum lengths defined above unless noted otherwise on the drawings.
2. All splices are to be wired together.
3. Splice and development lengths are the same value for horizontal and vertical bars.
4. F'm must be greater than or equal to 2,000 PSI.
5. Clear cover from face of block must be greater than 2".
LIGHT GAUGE METAL FRAMING
1. Light-gage metal framing shall be fabricated and installed in accordance with these drawings, the project specifications, and the latest editions of AISI S100, AISI S240, and ASTM C955. Shop drawings shall be submitted for review prior to fabrication and shall include member sizes, thicknesses, connections, bracing, bridging, openings, and all other details necessary for fabrication and installation.
2. All metal stud lintels shall be fabricated as detailed on the structural drawings. Shop drawings shall include lintel configurations, connections, and reinforcement.
3. Structural cold-formed steel framing shall be fabricated from steel conforming to ASTM A1003/A1003M and shall be hot-dip galvanized in accordance with ASTM A653/A653M.
Unless noted otherwise:
A. 54 mil (16 ga.) and thicker: Fy = 50 ksi B. 43 mil (18 ga.) and 33 mil (20 ga.): Fy = 33 ksi C. Provide G60 minimum coating for typical framing and G90 coating where specifically indicated on the structural drawings.
4. Member thicknesses indicated on the structural drawings are minimum design thicknesses. Gauge designations, where provided, are for reference only. Substituted members shall have equal or greater thickness, yield strength, and section properties than the members specified.
5. All welding of cold-formed steel members shall be performed by qualified welders in accordance with AWS D1.3.
6. Connections shall be installed using the fastener type, quantity, and spacing indicated on the structural drawings. Where not specifically detailed, connections shall be installed in accordance with the manufacturer's published requirements and shall develop the required design strength.
7. Cut cold-formed steel members using saws or shears. Flame cutting is not permitted. Field cutting, notching, or modification of structural framing beyond manufacturer-provided punchouts shall not be permitted without approval of the Engineer of Record.
8. Provide bridging, bracing, blocking, deflection tracks, and all required accessories as shown on the structural drawings or as required by AISI S240 for a complete and stable installation.
9. Field conditions that differ from those shown on the structural drawings shall be reported to the Engineer of Record prior to fabrication or installation.
DRAWN BY:
SCALE:
N O
T F
O R
C O
N S
T R
U C
T
IO
N
PROJECT:
SWRL STUDIO, LLC
2715 Folsom St Philadelphia, PA 19130
©2026
DATE:
PROJECT NO:
NOTES:
swrl studio
NO. DATE DESCRIPTION
ARCHITECT
STRUCTURAL ENGINEER
PRESTON STRUCTURAL SOLUTIONS, LLC
106 Gay Street, Unit 305 Philadelphia, PA 19127
As indicated
S001
REP
GENERAL
NOTES
2163 RIDGE
KORMAN'S
2163 RIDGE AVE
PHILADELPHIA, PA, 19121
08/07/26
152602
STRUCTURAL DRAWING LIST
SHEET
NUMBER SHEET NAME
S001 GENERAL NOTES
S100 STRUCTURAL PLANS
S200 FACADE ELEVATIONS
S300 STRUCTURAL SECTIONS
S200 2
S200
S200
BACKFILL
EXISTING VOID w/
COMPACTED FILL
4" SLAB ON GRADE,
REINF. w/ 6x6-W1.4xW1.4 W.W.F.
OVER 4" COMPACTED PENNDOT 2A STONE,
SEE CITY STANDARDS FOR ADD'L INFO
S300
NEW FULLY GROUTED CMU BASEMENT
WALL w/ CONT. CIP CONC. SPREAD
FOOTING, SEE SECTIONS
S300
S200 2
S200
S200
EXISTING FOUNDATION WALL
(TO REMAIN)
EXISTING SIDEWALK
(TO REMAIN)
DEMO EXISTING
ELEVATED SLAB
EXISTING FOUNDATION
WALL (TO REMAIN)
DEMO EXISTING
BILCO DOOR
EXISTING FOUNDATION
WALL (TO REMAIN)
EXISTING FOUNDATION WALL
(TO REMAIN)
EX. BILCO DOOR, NOT CURRENTLY ACCESSIBLE
FROM BASEMENT, CONTRACTOR TO VERIFY VOID
UNDER EXISTING DOOR HAS BEEN BACKFILLED w/
SOIL, BACKFILL WITH SOIL IF VOID EXISTS
DRAWN BY:
SCALE:
N O
T F
O R
C O
N S
T R
U C
T
IO
N
PROJECT:
SWRL STUDIO, LLC
2715 Folsom St Philadelphia, PA 19130
©2026
DATE:
PROJECT NO:
NOTES:
swrl studio
NO. DATE DESCRIPTION
ARCHITECT
STRUCTURAL ENGINEER
PRESTON STRUCTURAL SOLUTIONS, LLC
106 Gay Street, Unit 305 Philadelphia, PA 19127
3/16" = 1'-0"
S100
REP
STRUCTURAL
PLANS
2163 RIDGE
KORMAN'S
2163 RIDGE AVE
PHILADELPHIA, PA, 19121
08/06/26
152602
3/16" = 1'-0"
2 LEVEL 1
3/16" = 1'-0"
1 LEVEL 1 DEMO PLAN
N N
S300
S300
S300
TYP. OF
(4) LOC.
S300
S300
S300
S300
S300
S300
ALT.
DRAWN BY:
SCALE:
N O
T F
O R
C O
N S
T R
U C
T
IO
N
PROJECT:
SWRL STUDIO, LLC
2715 Folsom St Philadelphia, PA 19130
©2026
DATE:
PROJECT NO:
NOTES:
swrl studio
NO. DATE DESCRIPTION
ARCHITECT
STRUCTURAL ENGINEER
PRESTON STRUCTURAL SOLUTIONS, LLC
106 Gay Street, Unit 305 Philadelphia, PA 19127
1/4" = 1'-0"
S200
REP
FACADE
ELEVATIONS
2163 RIDGE
KORMAN'S
2163 RIDGE AVE
PHILADELPHIA, PA, 19121
08/06/26
152602
1/4" = 1'-0"
1 ELEVATION - RIDGE AVE - PROPOSED
1/4" = 1'-0"
2 ELEVATION - 22ND - PROPOSED
1/4" = 1'-0"
3 ELEVATION - NICHOLAS ST - PROPOSED
C
8" FULLY GROUTED CMU BLOCK,
SEE FOR ADD'L INFO
MATERIAL REQUIREMENTS
• BLOCK
1. NORMAL WEIGHT OR MEDIUM WEIGHT BLOCK
2. 8" WIDE x 8" TALL x 16" LONG
3. 2,000 PSI
• MORTAR
1. TYPE S
2. 1,800 PSI
• GROUT
1. 2,000 PSI OR GREATER
#5 HORIZ. DOWEL DRILL AND EPOXY w/
HILTI HIT-HY 200-R V3 INTO EX. FDN WALL
w/ 8" EMBED @ 8" o/c ALONG WALL HEIGHT
8" 8"
/1 S300
DOWELS TO MATCH SIZE AND
SPACING OF VERT. WALL REINF.
CONT. CAST-IN-PLACE
CONC. FTG. T.O. SLAB
FINISHED GRADE
T.O. FTG
CONTRACTOR NOTE: DO NOT BACKFILL
WALL UNTIL TOP OF WALL IS BRACED
BY FLOOR FRAMING.
#5 x @ 16"45"
20"
8" FULLY GROUTED CMU WALL, REINF. w/ #5 @ 16" VERT., #5 @ 48" o/c HORIZ, & 9 GA LADDER TYPE JOINT REINF @ 16" o/c
2" CLR.2" CLR.
6"
24"
(3) CONT. #4 BARS
2" CLR.
3" C
LR
WATERPROOFING
(BY CONTRACTOR)
PROVIDE MIN. 4" COMPACTED 3/4"
GRAVEL TO ACHIEVE BEARING
CAPACITY OF 2,000 PSF
NEW SOG,
SEE PLAN
(2) BAYS OF FULL DEPTH
BLOCK @ 24" o/c
EX. FLOOR JOIST
EX. FLOOR SHEATHING
EX. MASONRY ABOVE
PROVIDE BOND BEAM COURSE,
TYP. WHERE INDICATED
EX. CRACK (VIF)
LIMIT BRICK REMOVAL AND REPLACEMENT TO
AREAS WITH CRACKED OR FRACTURED UNITS ONLY.
DO NOT REMOVE ANY BRICK WITHOUT ADEQUATE
WALL BRACING IN PLACE.
EX. BRICK MASONRY
NOTES:
1. Bond pattern may vary. install new brick masonry in a bond pattern that matches the existing adjacent conditions.
2. Remove and reset existing brackets, supports, light fixtures, and other appurtenances as required to facilitate repair work. Reinstall to original locations unless otherwise directed.
3. Exercise care during mortar removal operations to avoid damaging the face of the existing brick. Any brick units damaged as a result of demolition or removal efforts shall be repaired or replaced at the contractor’s expense.
4. The color and texture of replacement brick and mortar shall be closely matched to the existing adjacent brickwork to maintain visual continuity. Provide samples for Architect and Owner to review for approval.
C
EN
T
ER
LI
N
E O
F C
RA
C
K
REPOINT MORTAR ALONG CRACK
FO
R
LE
N
G T
H O
F C
RA
C
K 8"
O N
C
EN
T
ER
LINE OF CRACK
20" 20"
SIMPSON STRONG-TIE HELI-TIE
STITCHING TIE. SPACE
VERTICALLY AS SHOWN
MADE WITH GRINDER
1 1/4" DEEP GROOVE
SIMPSON STRONG-TIE HELI-TIE STITCHING TIE
NOTES:
1. Refer to the manufacturer’s installation guidelines and product specifications for all additional requirements and instructions not explicitly detailed herein.
2. To accommodate corner conditions at wall intersections, Heli-Tie stitching ties may be field-bent to 90 degrees, provided a minimum bend radius of 1/4" is maintained.
3. Provide a 1-1/4" deep groove filled with non-shrink mortar.
4. Exercise care during mortar removal operations to avoid damaging the face of the existing brick. Any brick units damaged as a result of demolition or removal efforts shall be repaired or replaced at the contractor’s expense.
5. The color and texture of replacement brick and mortar shall be closely matched to the existing adjacent brickwork to maintain visual continuity. Provide samples for Architect and Owner to review for approval.
6. Stitch ties shall be installed at indicated spacing for the entire length of the crack.
7. First and last stitch ties shall be installed a minimum of one course beyond the top and bottom of the crack extent.
EX. BRICK MASONRY
3" MIN. ANCHOR
EDGE DISTANCE
CONCRETE BASE
600S200-43 (33 KSI) @ 24" o/c
TYP. STUD
1/4"x1 3/4" EMBED TITEN TURBO @ 24" o/c
600T125-33 (33 KSI) CONT. BOTTOM TRACK
(1)#10-16 SCREW PER STUD FLANGE
ClarkDietric…