WINDOW SIGNAGE ALLOWANCE
PER PHILADELPHIA CODE 14-904
GLASS AREA 13.8+18.7+13.8 = 60.1 SF
MAX. SIGNAGE AREA (20%) 12 SF
PROPOSED SIGNAGE AREA .7+1.2 = 1.9 SF - IN COMPLIANCE
DRAWN BY:
SCALE:
N O
T
FO
R C
O N
ST
R
UC
TI
O N
PROJECT:
SWRL STUDIO, LLC
2715 Folsom St Philadelphia, PA 19130
©2026
DATE:
PROJECT NO:
NOTES:
swrl studio
NO. DATE DESCRIPTION
ARCHITECT
STRUCTURAL ENGINEER
PRESTON STRUCTURAL SOLUTIONS, LLC
106 Gay Street, Unit 305 Philadelphia, PA 19127
1/4" = 1'-0"
A000
DH
COVER SHEET
2223 RIDGE
TANG'S
HALAL
2223 RIDGE AVE
PHILADELPHIA, PA 19121
10/24/26 2026_02
PROJECT LOCATION
PHILADELPHIA, PA 19121
SCOPE:
EXTERIOR RENOVATION OF RESTUARANT INCLUDING NEW AWNING,
EXTERIOR WALL SIGN AND WINDOW SIGNAGE
APPLICABLE CODE SUMMARY:
PHILADELPHIA BUILDING CODE (2021 INTERNATIONAL BUILDING CODE)
PHILADELPHIA EXISTING BUILDING CODE (2021 INTERNATIONAL EXISTING BUILDING CODE)
PHILADELPHIA ELECTRICAL CODE (2020 NATIONAL ELECTRIC CODE)
PROJECT DATA:
JURISDICTION: CITY OF PHILADELPHIA
ZONING: CMX-3 COMMUNITY COMMERCIAL MIXED-USE
BUSINESS NAME: TANG'S HALAL/CHINESE RESTAURANT
PHOTO: EXISTING - RIDGE AVE RENDERING : PROPOSED - RIDGE AVE RENDERING : PROPOSED - CECIL B. MOORE AVEPHOTO : EXISTING - CECIL B. MOORE AVE
2223 RIDGE AVE BASE SCOPE - DEMO
DB-01 UNINSTALL GUTTER AND DOWNSPOUT. PATCH AND REPAIR GLAZED BRICK AS NECESSARY
DB-02 UNINSTALL EXISTING FABRIC AWNING. PATCH AND REPAIR WALL
DB-03 UNINSTALL EXISTING SECURITY CAMERAS, STORE AND STORE AND PREPARE FOR REINSTALLATION DB-04 UNINSTALL EXISTING MAILBOXES, PREPARE FOR REINSTALLATION. PATCH GLAZED BRICK AS
NECESSARY
BASE SCOPE - PROPOSED
B-01 NEW VINYL WALL SIGNAGE
B-02 PREP & PAINT EXISTING OH ROLLING GATE. INSPECT FOR PROPER FUNCTION
B-03 NEW ALUMINUM AWNING TO COVER OH ROLLING GATE
B-05 NEW VINYL WINDOW SIGNAGE
B-07 PAINT EXISTING CONCERETE SILL AND STEP, GRAY
B-08 REINSTALL EXISTING SECURITY CAMERAS
B-09 PAINT EXISTING TRIM
B-10 PAINT EXISTING SIGN AREA
B-11 NEW ADDRESS NUMBERS
B-12 REINSTALL MAILBOXES, ALIGNED ON WALL
B-13 INSTALL NEW RESIDENTIAL SECURITY GATE
B-14 CLEAN GLAZED BRICK
AD-ALT SCOPE - PROPOSED
A-01 REQUIRED - NEW PARAPET TIEBACK, RESET MASONRY PARAPET TO PLUMB CONDITION, SEE STRUCTURE
SHEET INDEX
SHEET
NUMBER SHEET NAME BI
D S
ET
0/
/2
A000 COVER SHEET ●
A101 EXTERIOR ELEVATIONS ●
S001 GENERAL NOTES ●
S100 STRUCTURAL PLANS & SECTIONS ●
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
GENERAL NOTES:
ALL DRAWINGS ARE TO SCALE AS INDICATED. THE CONTRACTOR MUST
VERIFY THE SCALE BEFORE BEGINNING CONSTRUCTION. DO NOT SCALE
DIRECTLY FROM THE DRAWINGS.
IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN ALL
PERMITS FOR PLUMBING AND ELECTRICAL WORK, AND ANY OTHER WORK
NOT PERMITTED UNDER A GENERAL BUILDING PERMIT.
WORK NOT INDICATED ON A PART OF THE DRAWINGS BUT REASONABLY
IMPLIED TO BE SIMILAR TO THAT SHOWN AT CORRESPONDING PLACES,
SHALL BE REPEATED.
CONTRACTOR SHALL COORDINATE OPENINGS SHOWN ON THE DRAWINGS.
CONTRACTOR SHALL VERIFY AND/OR ESTABLISH ALL EXISTING CONDITIONS
AND DIMENSIONS AT THE SITE.
IF THE EXISTING FIELD CONDITIONS DO NOT PERMIT THE INSTALLATION OF
THE WORK IN ACCORDANCE WITH THE DETAILS SHOWN, THE CONTRACTOR
SHALL NOTIFY THE ARCHITECT IMMEDIATELY AND PROVIDE A SKETCH OF
THE CONDITION WITH CONTRACTOR’S PROPOSED MODIFICATION OF THE
DETAILS GIVEN ON THE CONTRACT DOCUMENTS.
IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND ALL
SUB-CONTRACTORSTO COORDINATE THE WORK AND VERIFY ALL
DIMENSIONS AND INSPECT CONDITIONS OF PRIOR WORK BY ALL TRADES
BEFORE PROCEEDING WITH ANY WORK. UNACCEPTABLE OR INCORRECT
PRIOR WORK SHALL BE REPAIRED OR REPLACED BEFORE STARTING WORK.
PROCEEDING WITH THE WORK SHALL CONSTITUTE ACCEPTANCE OF PRIOR
WORK.
WHERE WORK INVOLVES EXISTING SUPPORTING STRUCTURE, THE
CONTRACTOR SHALL PROVIDE SHORING AND PROTECTION REQUIRED TO
INSURE THE STRUCTURAL INTEGRITY OF THE EXISTING STRUCTURE.
UNLESS SPECIFICALLY SHOWN OR NOTED ON THE DRAWINGS, NO
STRUCTURAL MEMBER SHALL BE CUT, NOTCHED, BORED OR OTHERWISE
MODIFIED WITHOUT THE PERMISSION OF THE STRUCTURAL ENGINEER OF
RECORD
ALL PRODUCTS AND MATERIALS TO BE INSTALLED FOLLOWING
MANUFACTURERS' RECOMMENDATIONS.
CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES IN
THE DOCUMENTS PRIOR TO PROCEEDING WITH ANY WORK INVOLVED.
THE PURPOSE OF THESE DRAWINGS IS FOR THE CONTRACTOR TO INCLUDE
ALL THE LABOR, MATERIALS AND SERVICES REQUIRED FOR THE
COMPLETION OF ALL WORK SHOWN OR REASONABLY IMPLIED BUT NOT
LIMITED TO THAT EXPLICITLY SHOWN IN THE DOCUMENTS.
1.
2.
3.
4.
5.
PROJECT NOTES:
"BASE SCOPE" MEANS THE MINIMUM SCOPE OF WORK. ADDITIONAL SCOPE
MAY BE REQUIRED TO COMPLY WITH CODE, LIFE SAFETY AND STRUCTURAL
REQUIREMENTS.
"AD-ALT SCOPE" MEANS ADDITIONAL AND ALTERNATIVE SCOPE. THE
OWNER HAS THE RIGHT TO INCLUDE OR EXCLUDE ANY OR ALL ITEMS
IDENTIFIED IN THE FINAL SCOPE OF WORK
PAINTING APPLIES TO FIRST LEVEL ONLY UNLESS NOTED OTHERWISE
FOR NEW OR REPLACEMENT GATES, INSTALL SEE-THROUGH GRILLES ONLY
WINDOW DECALS TO HAVE CLEAR BACKGROUNDS RATHER AN OPAQUE
PANELS OR FULL-WINDOW COVERING, TYP.
EXISTING
RECESSED MURAL
EXISTING MAILBOX
TO REMAIN
EXISTING INTERNET
BOXES
EXISTING STONE ACCENT, TYP.
DB-02DB-02
DB-03DB-03
DB-01DB-01
EXISTING INTERNET
BOXES TO REMAIN
A101
8'
0"
A-01
B-14B-14
B-09B-09
B-01B-01
B-03B-03
B-08B-08
B-02B-02
B-07B-07
B-05B-05
13.8 sf 13.8 sf18.7 sf
.7 sf 1.2 sf
EXISTING
RECESSED MURAL
EXISTING SECURITY
CAMERA
DB-02DB-02
DB-03DB-03
DB-04DB-04
EXISTING SECURITY
CAMERA TO REMAIN
A-01
B-14B-14
B-10B-10
B-09B-09
B-11B-11
B-08B-08
B-02B-02
B-13B-13
B-12B-12
B-07B-07 +8'-0"
Z-CLIP ANCHOR, SEE STRUCTURE
8"
1 1/4"
42"
"1" ALUMINUM TUBE
METAL AWNING, POWDER
COATING, COLOR TBD
Z-CLIP ANCHOR, SEE STRUCTURE
RECESSED BAFFLE LIGHT
0"
28" 40" 40" 28"
11' - 4"
RECESSED LIGHT FIXTURE
AWNING OVERHEAD
EXISTING SIDEWALK
RIDGE AVE
SECURITY CAMERA
VINYL ADDRESS SIGN,
FONT: TBD
NEW METAL AWNING
A101
11' - 4"
WINDOW SIGNAGE ALLOWANCE
PER PHILADELPHIA CODE 14-904
GLASS AREA 13.8+18.7+13.8 = 60.1 SF
MAX. SIGNAGE AREA (20%) 12 SF
PROPOSED SIGNAGE AREA .7+1.2 = 1.9 SF - IN COMPLIANCE
DRAWN BY:
SCALE:
N O
T
FO
R C
O N
ST
R
UC
TI
O N
PROJECT:
SWRL STUDIO, LLC
2715 Folsom St Philadelphia, PA 19130
©2026
DATE:
PROJECT NO:
NOTES:
swrl studio
NO. DATE DESCRIPTION
ARCHITECT
STRUCTURAL ENGINEER
PRESTON STRUCTURAL SOLUTIONS, LLC
106 Gay Street, Unit 305 Philadelphia, PA 19127
As indicated
A101
FC
EXTERIOR
ELEVATIONS
2223 RIDGE
TANG'S
HALAL
2223 RIDGE AVE
PHILADELPHIA, PA 19121
10/24/26 2026_02
SCALE: 1/4" = 1'-0"
3 ELEVATION - RIDGE AVE - DEMO
SCALE: 1/4" = 1'-0"
4 ELEVATION - RIDGE AVE - PROPOSED
SCALE: 1/4" = 1'-0"
5 ELEVATION - CECIL B MOORE - DEMO
SCALE: 1/4" = 1'-0"
6 ELEVATION - CECIL B MOORE - PROPOSED
SCALE: 1 1/2" = 1'-0"
7 AWNING DETAILS
SCALE: 1/2" = 1'-0"
1 FLOOR PLAN - RIDGE
SCALE: 1/2" = 1'-0"
2 AWNING ENLARGED ELEVATION
BASE SCOPE - DEMO
DB-01 UNINSTALL GUTTER AND DOWNSPOUT. PATCH AND REPAIR GLAZED BRICK AS NECESSARY
DB-02 UNINSTALL EXISTING FABRIC AWNING. PATCH AND REPAIR WALL
DB-03 UNINSTALL EXISTING SECURITY CAMERAS, STORE AND STORE AND PREPARE FOR REINSTALLATION DB-04 UNINSTALL EXISTING MAILBOXES, PREPARE FOR REINSTALLATION. PATCH GLAZED BRICK AS
NECESSARY
BASE SCOPE - PROPOSED
B-01 NEW VINYL WALL SIGNAGE
B-02 PREP & PAINT EXISTING OH ROLLING GATE. INSPECT FOR PROPER FUNCTION
B-03 NEW ALUMINUM AWNING TO COVER OH ROLLING GATE
B-05 NEW VINYL WINDOW SIGNAGE
B-07 PAINT EXISTING CONCERETE SILL AND STEP, GRAY
B-08 REINSTALL EXISTING SECURITY CAMERAS
B-09 PAINT EXISTING TRIM
B-10 PAINT EXISTING SIGN AREA
B-11 NEW ADDRESS NUMBERS
B-12 REINSTALL MAILBOXES, ALIGNED ON WALL
B-13 INSTALL NEW RESIDENTIAL SECURITY GATE
B-14 CLEAN GLAZED BRICK
AD-ALT SCOPE - PROPOSED
A-01 REQUIRED - NEW PARAPET TIEBACK, RESET MASONRY PARAPET TO PLUMB CONDITION, SEE STRUCTURE
A.B. ANCHOR BOLT
A.F.F. ABOVE FINISH FLOOR
ADDL. ADDITIONAL
ALT. ALTERNATE
ARCH. ARCHITECT
B.C.E. BOTTOM CHORD EXTENSION
B.O. BOTTOM OF
BLDG. BUILDING
BM. BEAM
BOTT. BOTTOM
BRG. BEARING
BSMT. BASEMENT
BTWN. BETWEEN
CL CENTERLINE
CANT. CANTILEVER
CMU CONCRETE MASONRY UNIT
COL. COLUMN
CONC. CONCRETE
CONN. CONNECTION
CONT. CONTINUOUS
CTRD. CENTERED
Ø DIAMETER
DWG. DRAWING
E.F. EACH FACE
E.O.D. EDGE OF DECK
E.O.S. EDGE OF SLAB
E.W. EACH WAY
EA. EACH
EL. ELEVATION
ELEV. ELEVATOR
EMBED. EMBEDMENT
EQ. EQUAL
EQUIP. EQUIPMENT
EWB EACH WAY BOTTOM
EX. EXISTING
EXIST. EXISTING
EXP. EXPANSION
EXT. EXTERIOR
FDN. FOUNDATION
FIN. FINISH
FLR. FLOOR
FT. FEET
FTG. FOOTING
GA. GAGE
GALV. GALVANIZED
H.P. HIGH POINT
HORIZ. HORIZONTAL
I.F. INSIDE FACE
IN. INCHES
INFO. INFORMATION
INT. INTERIOR
JT. JOINT
EWT EACH WAY TOP
BP_ BEARING PLATE
GB_ GRADE BEAM
k KIP k-ft KIP-FEET
L.P. LOW POINT
L.W. LIGHT WEIGHT
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LWB LONG WAY BOTTOM
M.E.P. MECHANICAL ELECTRICAL PLUMBING
M.S.T. METAL STUD TRUSS
MAX. MAXIMUM
MECH. MECHANICAL
MEZZ. MEZZANINE
MFR. MANUFACTURER
MIN. MINIMUM
MISC. MISCELLANEOUS
N.T.S. NOT TO SCALE
N.W. NORMAL WEIGHT
o/c ON CENTER
PL PLATE
PC PILE CAP
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PTN. PARTITION
REINF. REINFORCEMENT
REQ'D. REQUIRED
RET'G. RETAINING
S.F. STEP FOOTING
S.O.G. SLAB ON GRADE
SCHED. SCHEDULE
SECT. SECTION
SIM. SIMILAR
SPECS. SPECIFICATIONS
STIFF. STIFFENER
STRUCT. STRUCTURAL
SWB SHORT WAY BOTTOM
T&B TOP AND BOTTOM
T. TOP
T.O. TOP OF
T.O.C. TOP OF CONCRETE
T.O.S. TOP OF STEEL
T.S. THICKENED SLAB
TCELE TOP CHORD EXTENSION LEFT END
TCERE TOP CHORD EXTENSION RIGHT END
TDS TURN DOWN SLAB
THK. THICK OR THICKENED
TYP. TYPICAL
U.N.O. UNLESS NOTED OTHERWISE
V.I.F. VERIFY IN FIELD
VERT. VERTICAL
W.R.T. WOOD ROOF TRUSS
w/ WITH
WWF WELDED WIRE FABRIC
P.C. PRECAST
P.A.F. POWDER ACTUATED FASTENER
M.P. MASONRY PIER
N.B.L. NON BEARING LINTEL
W.P. WALL PLATE
W.C. WET COLUMN
ABBREVIATIONS
PROJECT DESCRIPTION
1. Project consists of a facade improvment to an existing mixed use building. Existing superstructure is
3 levels above grade and 1 level below grade. Foundations consist of CMU and stone foundation walls. Superstructure is wood floor sheathing over rough sawn wood framing.
2. This description is for general orientation only. The General Contractor is responsible for all scope items described in the drawings and project specifications as well as for all material and labor that can reasonably be inferred there from.
GENERAL APPLICATION
1. These structural drawings are intended to be used in conjunction with the project’s architectural, mechanical, and electrical drawings. All disciplines must be reviewed collectively to fully understand the design intent and construction requirements.
2. Contractors shall not bid or proceed with any portion of the work without thoroughly reviewing all relevant project documents, including but not limited to architectural, mechanical, and electrical drawings and specifications.
3. Any perceived discrepancies, omissions, or ambiguities in the structural drawings shall be promptly brought to the attention of the Structural Engineer. No related work shall proceed until the Engineer has issued written clarification or direction.
4. The Contractor is responsible for notifying the Structural Engineer in writing of any proposed deviation or substitution from the contract documents. Approval or review of shop drawings, product data, or similar submittals by the Structural Engineer shall not constitute acceptance of deviations unless such deviations have been clearly and explicitly identified in writing at the time of submission.
MISCELLANEOUS NOTES
1. The Contractor is solely responsible for implementing and maintaining all safety measures, programs, and precautions associated with the execution of the work on this project.
2. The Contractor shall protect all persons and property, both on-site and adjacent to the project site, from injury, damage, or loss. Responsibility for such protection lies exclusively with the Contractor.
3. The selection and execution of construction means, methods, techniques, sequences, and procedures—including the erection of structural elements—are entirely the responsibility of the Contractor.
4. The structure is engineered to perform as a complete system only upon full completion and under the design loads specified. The Contractor is responsible for ensuring construction-phase stability, including evaluating the structure’s capacity to support construction loads. Provide all temporary bracing, shoring, and other measures required to maintain stability and safety during construction.
5. No openings or modifications to structural elements—including changes in size, shape, or location— shall be made without prior written approval from the Structural Engineer.
6. Openings measuring 1'-4" or less on a side are typically not shown on the structural drawings. Refer to the drawings of other design disciplines for the locations and dimensions of such openings.
7. Openings in floors and roofs for utility penetrations are not detailed on structural drawings. The Contractor shall coordinate the required locations and dimensions with the respective trade responsible for the utility work.
8. All proposed openings in structural members shall be clearly indicated on shop drawings and submitted for review. Any opening not shown on the structural drawings is subject to written acceptance and shall not be implemented without prior approval.
9. Fireproofing requirements for structural components are not depicted on these drawings. Refer to project specifications and architectural documents for fireproofing locations and requirements.
10. Do not scale these drawings. Use only the dimensions shown. In the event of discrepancies or conflicts, obtain clarification from the Architect and Structural Engineer before proceeding with affected work.
11. No structural repairs, alterations, or modifications shall be undertaken without prior review and written approval from the Structural Engineer. All proposed modifications must be supported by detailed drawings and structural calculations prepared by a licensed Professional Engineer registered in the state where the project is located and retained by the Contractor.
12. If framed floors are used for staging or temporary material storage, the Contractor shall verify that the applied unit loads do not exceed the design loads of the floor framing system.
QUALITY ASSURANCE AND QUALITY CONTROL
1. The Contractor is solely responsible for ensuring the quality of all workmanship and materials, including those provided by subcontractors and suppliers.
2. Testing or inspections performed by or on behalf of the Owner do not relieve the Contractor of the obligation to perform all work in full compliance with the Contract Documents.
3. Workmanship: The Contractor shall correct, at their own expense, any work that fails to meet specified requirements.
4. All deficient work shall be corrected using methods acceptable to the Architect. Any additional costs incurred by the Architect in reviewing or approving corrective work shall be the responsibility of the Contractor.
5. Testing and special inspections required by the structural drawings, applicable building code, and the local authority having jurisdiction shall be performed by the Owner’s Testing Agency. The agency must comply with ASTM E329 and shall, upon completion of the work, provide a certificate of compliance signed by a Professional Engineer licensed in the state where the project is located, and responsible for the special inspections and testing.
6. The individual overseeing soils and foundation testing on behalf of the Testing Agency shall be a licensed Professional Engineer specializing in geotechnical engineering, herein referred to as the Geotechnical Engineer. This individual is responsible for verifying that soils, earthwork, and foundations conform to the foundation design and the referenced geotechnical report. Refer to the “Foundations” section of these General Notes for further requirements.
7. Refer to the “Special Inspections” section of these General Notes for a detailed list of required inspections and testing.
SPECIAL INSPECTION
1. Special inspections and testing shall be performed in accordance with the requirements of the applicable building code, the local authority having jurisdiction, and the construction documents.
Refer to the “Quality Assurance” section of these General Notes for additional guidance.
2. The Contractor shall coordinate and schedule all required inspections and testing in advance of commencing work subject to such requirements. Reasonable notice must be provided to the Special Inspector to facilitate timely performance.
3. Any deficiencies identified during inspections or testing shall be corrected to the satisfaction of the Testing Agency before acceptance of the work.
4. Inspections conducted by local code officials do not substitute for the inspections and testing required to be performed by the Owner’s Testing Agency, as stipulated in the construction documents.
SPECIFICATIONS
1. These General Notes are intended to function as the structural portion of project specifications.
SUBMITTALS
1. Refer to the “Materials” section of these General Notes for a list of items requiring shop drawing submittals.
2. Submit all required documentation (e.g., manufacturer’s product data, shop drawings, etc.) in electronic format (PDF or equivalent).
3. Reproducible copies of the contract documents shall not be used as the basis for shop drawings or submittals.
4. All submittals shall be transmitted directly to Preston Structural Solutions LLC for review and further distribution.
5. Prior to submission, submittals must be reviewed by both the Contractor and applicable
Subcontractors. Each drawing shall bear the Contractor’s approval stamp, confirming coordination of dimensions, quantities, and interface with other trades in accordance with the contract documents.
6. Allow a minimum of 14 calendar days for the review process following receipt of complete submittal packages.
7. Reviewed submittals will be returned to the Contractor with comments, if any, by Preston Structural Solutions LLC in electronic format.
COMMON NAIL DIMENSIONS
Common Nail (Steel Wire) Minimum Length (in)
6d
0.131
0.148
2 1/2
3 1/20.162
Minimum Diameter (in)
8d
10d
16d
0.113
DESIGN VALUES FOR DIMENSIONAL LUMBER
Species & Grade Compressive
Stress
Select Structural
Flexural Stress
1,400 psi
No. 1
No. 2
Stud
975 psi
850 psi
675 psi
1,500 psi
1,350 psi
1,300 psi
800 psi
Horizontal Shear Stress
150 psi
150 psi
150 psi
150 psi
Modulus of Elasticity
1,600 ksi
1,500 ksi
1,300 ksi
1,200 ksi
HEM-FIR (HF)
Building Code: 2021 International Building Code (Note 1)
Structural Design Criteria
Local Jurisdiction: Philadelphia, PA Risk Category: II
Foundations:
Notes:
1. The governing building code defines the applicable edition of referenced codes and standards. Where governing building code does not define referenced codes and standards, the latest edition shall be used.
2. Foundation design criteria determined utilizing 2021 IBC minimum bearing capacity tables. Contractor shall verify in-situ soils reflect the provided bearing capacity.
Wind Loading Basic Wind Speed Exposure Category
Vult= 114 MPH B
Seismic Loading Seismic Importance Factor, Ie 1.00 Mapped Spectral Response Acceleration Ss 0.181 S1 0.047 Site Class D Spectral Response Coefficients Sds 0.193 Sd1 0.076 Snow Loading Ground Snow Load, Pg 25 PSF Minimum Flat Roof Snow Load, Pf 21 PSF
Allowable Bearing Capacity 2,000 PSF Minimum Frost Depth 36 IN
GCpi +/-0.18 Ultimate Components & Cladding Wind Design Pressure, PSF 20ft2 50ft2 100ft2
Wall Pressures
-22.2/20.4 -21.0/19.2 -20.0/18.2Interior (Zone 4) -26.6/20.4 -24.1/19.2 -22.2/18.2Corner (Zone 5)
Importance Factor, IS 1.0
WOOD FRAMING
GENERAL:
1. All wood construction shall conform to ANSI/AWC NDS unless otherwise noted. A current copy of this standard shall be maintained on-site by the Contractor at all times.
2. Refer to the “Wood Materials Tables” for specified material types and properties.
3. Qualifications: All carpentry work shall be performed by tradespeople experienced with projects of comparable size and complexity and familiar with conventional light-frame construction and the minimum fastening requirements of the IBC.
PRODUCTS:
1. All wood framing shall be at a moisture content of 19% or less and shall be marked S-Dry (surface dried) or KD (kiln dried).
2. Unless noted otherwise, all sizes noted on these drawings are nominal. Actual sizes are based on
"Minimum Dressed-Dry" dimensions according to American Softwood and Lumber Standard PS20-10.
Members which the architect, engineer, or inspector judge to be misgraded shall be reinspected by a qualified lumber grader. Members which have permissible grade characteristics in such combination to affect the performance of the member are also subject to replacement at the discretion of the architect, engineer, or inspector.
3. Unless noted otherwise, all manufactured framing sizes are based on specified manufacturers published information.
4. See plan notes for wall framing material and spacing.
5. Wood I-joists: where framing members are noted TJI on the drawings, use engineered products by
Weyerhaeuser or approved equal.
6. Structural Panels: Sheathing for roofs and walls shall conform to APA PS-2 standards. All panels shall be Exposure 1, unless noted otherwise.
7. Sills: Sill plates shall be pressure treated Southern Pine stamped to show compliance with AWPA standards.
8. Wood stud wall framing elements including but not limited to headers, top plates, sole plates, cripple studs, trimmers, and sills shall match stud member specification, unless noted otherwise.
CONNECTORS:
1. All connectors, anchors, bolts, and fasteners in contact with preservative-treated wood shall be either hot-dipped galvanized (G90 or G185) or stainless steel (Type 304 or 316).
2. Provide anchor bolts at all foundation top surfaces to secure sill plates. See typical details for anchor size, spacing, and embedment.
3. J- and L-type anchor bolts are acceptable for sill plate anchorage.
4. Provide plate washers at all anchor bolt connections in shear walls. Refer to the “Typical Wood Shear
Wall” details for configuration.
5. All nailing shall meet or exceed the minimum requirements of IBC Table 2304.9.1 unless more stringent requirements are indicated in the drawings or notes.
6. Nails shall conform to ASTM F1667 and be steel common wire type.
7. Pre-drill nail holes where necessary to prevent splitting of wood members.
8. Steel plates used in wood construction shall conform to ASTM A36.
9. Bolts shall conform to ASTM A307.
10. Exposed bolts not in contact with treated wood may be plain, uncoated steel.
11. Bolt holes shall be 1/16" larger than the bolt diameter unless specified otherwise.
12. All bolts shall be retightened before enclosure or concealment.
13. Lag screws shall penetrate a minimum of 8 times the shaft diameter into the main member unless otherwise noted.
14. Diagonal (toe-nail) lag screws shall have a minimum edge distance of 4 times the shaft diameter.
INSTALLATION:
1. Built-up wood columns concealed within wall framing may be constructed using multiple 2x members.
Do not splice individual laminations. Refer to typical details for required nailing.
2. At roof and floor levels, install wood panels with their long dimension perpendicular to supports and stagger short edges.
3. Refer to plan notes for nailing patterns at roof and floor sheathing.
4. Refer to the plans for locations requiring special blocking and additional fastening.
5. Refer to plan notes for vertical wall sheathing requirements.
6. For all designated shear walls, sheathing contributes to lateral resistance. Refer to typical details for required fastening of sheathing to framing members.
7. Provide solid blocking with flat 2x4s at all sheathing edges within shear walls.
FRAMING TOLERANCES:
1. Wall and partition layout: ±¼" from intended position.
2. Plates and runners: Deviation not to exceed ¼" in 8'-0" from a straight line.
3. Studs: Out-of-plumb tolerance of ¼" in 8'-0", not cumulative.
4. Face of framing: Deviation from true plane not to exceed ¼" in 8'-0".
WOOD STRUCTURAL PANEL REQUIREMENTS
Supporting Element Minimum Thickness
Roof over roof joists
24 OC Single Floor
32/16
15/32"
APA Span Rating
32/16
23/32"
15/32"
Floors (Sturd-I T&G)
Walls
MASONRY MATERIALS TABLE
Material Standard
ASTM C 90Hollow Concrete Masonry Units
ASTM C 476Grout
ASTM C 270Mortar
ASTM A615-grade 60Reinforcing
ASTM A706-grade 60Welded Reinforcing Bars
ASTM A651Wire Reinforcing
NOTES:
1. Provide lightweight hollow concrete masonry units for general use. Provide normal weight or solid units where indicated.
2. Mortar for concrete masonry shall be type S at exterior walls and type N at interior walls.
3. Hydrated lime required in all mortar.
4. Wire joint reinforcing shall be ladder type.
MASONRY STRENGTH TABLE
Element Specified Compressive Strength
Clay Masonry f'm = 2500 psi f'g>=f'm (2000psi minimum) f'm = 2000 psi f'g = 1.0*f'm (2000 psi minimum)
Grout for Clay Masonry
Concrete Masonry
Grout for Concrete Masonry
LIGHT GAUGE METAL FRAMING
1. Light-gage metal framing shall be fabricated and installed in accordance with these drawings, the project specifications, and the latest editions of AISI S100, AISI S240, and ASTM C955. Shop drawings shall be submitted for review prior to fabrication and shall include member sizes, thicknesses, connections, bracing, bridging, openings, and all other details necessary for fabrication and installation.
2. All metal stud lintels shall be fabricated as detailed on the structural drawings. Shop drawings shall include lintel configurations, connections, and reinforcement.
3. Structural cold-formed steel framing shall be fabricated from steel conforming to ASTM A1003/A1003M and shall be hot-dip galvanized in accordance with ASTM A653/A653M. Unless noted otherwise:
A. 54 mil (16 ga.) and thicker: Fy = 50 ksi B. 43 mil (18 ga.) and 33 mil (20 ga.): Fy = 33 ksi C. Provide G60 minimum coating for typical framing and G90 coating where specifically indicated on the structural drawings.
4. Member thicknesses indicated on the structural drawings are minimum design thicknesses. Gauge designations, where provided, are for reference only. Substituted members shall have equal or greater thickness, yield strength, and section properties than the members specified.
5. All welding of cold-formed steel members shall be performed by qualified welders in accordance with
AWS D1.3.
6. Connections shall be installed using the fastener type, quantity, and spacing indicated on the structural drawings. Where not specifically detailed, connections shall be installed in accordance with the manufacturer's published requirements and shall develop the required design strength.
7. Cut cold-formed steel members using saws or shears. Flame cutting is not permitted. Field cutting, notching, or modification of structural framing beyond manufacturer-provided punchouts shall not be permitted without approval of the Engineer of Record.
8. Provide bridging, bracing, blocking, deflection tracks, and all required accessories as shown on the structural drawings or as required by AISI S240 for a complete and stable installation.
9. Field conditions that differ from those shown on the structural drawings shall be reported to the Engineer of Record prior to fabrication or installation.
STEEL MATERIALS DESIGNATION
Material Standard
W and WT Sections ASTM A992 (50ksi) or ASTM 572 Gr. 50 (50ksi)
M, S, C, MC, L, MT, ST Sections ASTM A36 (36 ksi)
Plates, Bars, and Threaded Rod ASTM ASTM A36 (36ksi)
Bolts
- typical (Group A)
- where indicated as A307
ASTM F3125 Grade A325 or F1852 ASTM A307 Gr. A
Nuts ASTM A563, Heavy Hex
Washers ASTM F436, except plate washers to be
ASTM A36
All Threaded Rod and Threaded Studs, UNO ASTM A36
Weld Electrodes E70 (70ksi)
NOTES:
1. All bolts are snug tight.
STRUCTURAL STEEL
GENERAL:
1. All structural steel work shall conform to AISC 360. Dimensional tolerances shall conform to AISC 303 unless noted otherwise. A copy of these references shall be maintained on site by the Contractor at all times.
2. Refer to the “Steel Materials” table for required steel material specifications.
3. Qualifications: Both the Fabricator and Erector shall demonstrate prior experience with projects of similar size, scope, and complexity.
TESTING AND INSPECTIONS:
1. All inspections and testing shall comply with AISC 360 and IBC Chapter 17. Required inspections include welding, high-strength bolting, anchor rod placement, joint details, fabricated components, and erected framing. Required testing includes ultrasonic testing (UT) of full penetration welds, bolt tension verification, and shear stud bend tests.
2. See the “Special Inspections and Testing” table for a summary of required inspections.
SUBMITTALS:
1. All structural steel submittals shall conform to AISC 360.
2. Submittals shall include:
A. Erection drawings B. Shop drawings C. Certified mill test reports for all structural steel
3. Erection Drawings: Provide plan views at a minimum scale of 1/8" = 1'-0", including all necessary elevations, sections, and connection details for complete steel frame erection.
4. Shop Drawings: Include member piece drawings with all cuts, dimensions, holes, cambers, welds, and connection details required for fabrication.
CONNECTIONS:
1. All connections shall be designed by the fabricator unless noted otherwise. If a connection is not detailed in the Contract Documents, the Contractor shall request design information from the EOR.
BOLTING:
1. Bolted connections indicated as slip-critical or using oversized/long-slotted holes in shear shall:
A. Be slip-critical B. Have Class A faying surfaces C. Be fully tensioned
2. Bolts subject to non-static loads, tensioned Group B fasteners, or built-up members shall be fully tensioned.
3. Bolts not subject to the above may be installed to snug-tight condition.
4. A307 bolts shall only be used where explicitly indicated.
WELDING:
1. Fillet Welds: Use sizes as indicated, but not less than AISC minimums.
2. Groove Welds: Full-penetration unless noted otherwise.
3. All welds are continuous unless otherwise noted.
SHOP CLEANING AND PAINTING:
1. Primed Steel: Where painting is indicated without further specification, prepare to SSPC-SP2 and apply one coat of rust-inhibitive primer to 1 mil dry film thickness.
2. Galvanized Steel: Clean and galvanize per ASTM A123. Repair damage and welds per ASTM A780.
Provide vent holes in HSS members and plug vertically oriented tubes.
3. Other Coatings: Where specific coating systems are indicated, comply with the coating manufacturer’s surface preparation and application requirements.
ERECTION:
1. Do not finalize bolting or welding until the steel structure has been adequately aligned and stabilized.
2. Field modifications for fabrication or erection errors are permitted only with prior written approval of the EOR. Gas-cut surfaces shall be finished per AWS D1.1.
DRAWN BY:
SCALE:
N O
T F
O R
C O
N S
T R
U C
T
IO
N
PROJECT:
SWRL STUDIO, LLC
2715 Folsom St Philadelphia, PA 19130
©2026
DATE:
PROJECT NO:
NOTES:
swrl studio
NO. DATE DESCRIPTION
ARCHITECT
STRUCTURAL ENGINEER
PRESTON STRUCTURAL SOLUTIONS, LLC
106 Gay Street, Unit 305 Philadelphia, PA 19127
As indicated
S001
REP
GENERAL
NOTES
2223 RIDGE
TANG'S
HALAL
2223 RIDGE AVE
PHILADELPHIA, PA, 19121
08/06/26
152602
STRUCTURAL DRAWING LIST
SHEET
NUMBER SHEET NAME
S001 GENERAL NOTES
S100 STRUCTURAL PLANS & SECTIONS
S100
S100
S100
PREFAB CANOPY
(BY OTHERS)
PREFAB CANOPY
(BY OTHERS)
300ZG-54
@ 16" o/c
EX. FLOOR SHEATHING
(2) BAYS OF FULL DEPTH 2x BLOCKING @ 24" o/c (MAX.)
400S200-54 (33 KSI) @ 24" o/c
(MAX.) TYP. WHERE INDICATED
300ZG-54 @ 16" o/c EX. FLOOR SHEATHING
(3)#10-16 SCREWS,
TYP. WHERE
INDICATED
CONTRACTOR NOTES:
1. EXISTING STEEL BEAM AND FLOOR FRAMING WERE NOT VISIBLE AT THE TIME OF THE FIELD SURVEY. CONTRACTOR SHALL EXPOSE
THE EXISTING FRAMING AND VERIFY THAT THE EXISTING MEMBER SIZES, ORIENTATION, AND GEOMETRY ARE CONSISTENT WITH THE CONDITIONS SHOWN AND SUITABLE FOR THE PROPOSED CONNECTION DETAILS. CONTACT THE ENGINEER OF RECORD IF EXISTING CONDITIONS DIFFER FROM THOSE SHOWN OR IF THE PROPOSED DETAILS CANNOT BE INSTALLED AS INDICATED.
2. WHERE EXISTING FLOOR JOISTS FRAME PERPENDICULAR TO THE EXTERIOR WALL, OMIT THE FULL-DEPTH 2x BLOCKING AND FASTEN THE LIGHT-GAUGE STEEL FRAMING DIRECTLY TO THE EXISTING FLOOR JOISTS IN ACCORDANCE WITH THE CONNECTION
REQUIREMENTS SHOWN.
ATTACHMENT METHOD #1 (DEEP PERIMETER BEAM)
ATTACHMENT METHOD #2 (SHALLOW PERIMETER BEAM)
METAL STUD OR STOREFRONT
WINDOW BELOW
STOREFRONT WINDOW BELOW
(OMIT AND PROVIDE FULL HEIGHT STUD
AT METAL STUD WALL LOCATIONS)
(2)0.157" SST PDPA/PDPAT-62KP
@ EA. STUD
CONT. 600T200-43 (33) TOP TRACK
FULL DEPTH 2x BLOCKING @ 48" o/c (MAX.)
CONT. GAUGE ANGLE
CONN. TO STRUCT. BY
CANOPY SUPPLIER
400S200-54 (33 KSI) @ 48" o/c (MAX.)
(3)#10-16 SCREWS
CONN. TO STRUCT. BY
CANOPY SUPPLIER
NOTES:
1. Remove existing mortar to a minimum depth of 3/4", or until sound, intact mortar is encountered—whichever is greater.
2. Exercise care during mortar removal operations to avoid damaging the face of the existing brick. Any brick units damaged as a result of demolition or removal efforts shall be repaired or replaced at the contractor’s expense.
3. The color and texture of replacement brick and mortar shall be closely matched to the existing adjacent brickwork to maintain visual continuity.
FINISH JOINT PROFILE TO
MATCH EX.
INSTALL MORTAR IN 1/4"
LIFTS UNTIL THUMBPRINT
HARD
EX. BRICK MASONRY
M A
S O
N
RY
O R
U T
IL
IZ
E
EX
IS
T
IN
G
W H
ER
E
PO
S
S
IB
LE
RE
S
ET
P A
RA
PE
T T
O P
LU
M
B, M
A T
C H
E X
3/16
3/16
FLASHING (SEE ARCH)
GALV. (OR PRIMED w/ ZINC RICH PRIMER) L5x5x3/8, TOUCH UP WELDS w/ ZINC RICH
PRIMER AFTER WELDING GALV. SURFACES
(2)2x FLAT BLOCKING, SECURE EA. PLY w/ (2)10d TOE NAILS TO EX. RAFTERS EA. END, TYP. (3) BAYS UNDER ANGLE
DECORATIVE STRUCTURAL STAR
BOLT (OR SIMILAR), SELECTED BY
ARCH, SUBMIT TO EOR FOR REVIEW,
COAT WITH ZINC RICH PRIMER AND
PAINT PER ARCH.
3/4"Ø ZINC PLATED
THREADED ROD
GALV. (OR PRIMED w/ ZINC RICH PRIMER) L5x5x3/8, TOUCH UP WELDS w/ ZINC RICH
PRIMER AFTER WELDING GALV. SURFACES
GALV. (OR PRIMED w/ ZINC RICH PRIMER) L5x5x3/8 (ENGAGE (4) JOISTS MIN.), TOUCH UP WELDS w/ ZINC RICH PRIMER AFTER
WELDING GALV. SURFACES
(3)3/4" A325 THRU BOLTS
S100
S100
S100
S100
DRAWN BY:
SCALE:
N O
T F
O R
C O
N S
T R
U C
T
IO
N
PROJECT:
SWRL STUDIO, LLC
2715 Folsom St Philadelphia, PA 19130
©2026
DATE:
PROJECT NO:
NOTES:
swrl studio
NO. DATE DESCRIPTION
ARCHITECT
STRUCTURAL ENGINEER
PRESTON STRUCTURAL SOLUTIONS, LLC
106 Gay Street, Unit 305 Philadelphia, PA 19127
As indicated
S100
REP
STRUCTURAL
PLANS &
SECTIONS
2223 RIDGE
TANG'S
HALAL
2223 RIDGE AVE
PHILADELPHIA, PA, 19121
08/07/26
152602
3/4" = 1'-0"
4 CANOPY CONNECTION DETAIL
1/4" = 1'-0"
2 ELEVATION - CECIL B MOORE - PROPOSED
1/4" = 1'-0"
1 ELEVATION - RIDGE AVE - PROPOSED
3" = 1'-0"
6 TYPICAL REPOINTING MORTAR JOINT DETAIL
3/4" = 1'-0"
5 PARAPET REINFORCEMENT DETAIL
3/16" = 1'-0"
3 ROOF FRAMING PLAN
N
| A000 - COVER SHEET |
| A101 - EXTERIOR ELEVATIONS |
| S001 - GENERAL NOTES |
| S100 - STRUCTURAL PLANS & SECTIONS |