WINDOW SIGNAGE ALLOWANCE

PER PHILADELPHIA CODE 14-904

GLASS AREA 22.8+8.3+16.3+7.3+19.8 = 74.5 SF

MAX. SIGNAGE AREA (20%) 15 SF

PROPOSED SIGNAGE AREA 5.4+.7+.5+5.4 = 12 SF - IN COMPLIANCE

DRAWN BY:

SCALE:

N O

T

FO

R C

O N

ST

R

UC

TI

O N

PROJECT:

SWRL STUDIO, LLC

2715 Folsom St Philadelphia, PA 19130

©2026

DATE:

PROJECT NO:

NOTES:

swrl studio

NO. DATE DESCRIPTION

ARCHITECT

STRUCTURAL ENGINEER

PRESTON STRUCTURAL SOLUTIONS, LLC

106 Gay Street, Unit 305 Philadelphia, PA 19127

1/4" = 1'-0"

A000

DH

COVER SHEET

1754 N 27th

1754 N 27th St

PHILADELPHIA, PA 19121

10/24/26 2026_02

PROJECT LOCATION

PHILADELPHIA, PA 19121

SCOPE:

EXTERIOR RENOVATION OF EXISTING CORNER STORE INCLUDING NEW WALL

SIGNAGE AND WINDOW SIGNAGE

APPLICABLE CODE SUMMARY:

PHILADELPHIA BUILDING CODE (2021 INTERNATIONAL BUILDING CODE)

PHILADELPHIA EXISTING BUILDING CODE (2021 INTERNATIONAL EXISTING BUILDING CODE)

PHILADELPHIA ELECTRICAL CODE (2020 NATIONAL ELECTRIC CODE)

PROJECT DATA:

JURISDICTION: CITY OF PHILADELPHIA

ZONING: CMX-1 NEIGHBORHOOD COMMERCIAL MIXED-USE-1

BUSINESS NAME: GARY'S MOM & POP GROCERY & DELI

PHOTO: EXISTING RENDERING: PROPOSED - 27TH ST

1754 N 27TH ST BASE SCOPE - DEMO

DB-01 UNINSTALL EXISTING FABRIC AWNING. PATCH AND REPAIR WALL @ ANCHOR

LOCATIONS

DB-02 REMOVE REFLECTIVE FILM AND STICKERS AND CLEAN WINDOWS

BASE SCOPE - PROPOSED

B-01 NEW 1/2" PVC WALL SIGNAGE

B-02 PREP & PAINT EXISTING OH ROLLING GATE. INSPECT FOR PROPER FUNCTION.

COLOR = BLACK

B-03 NEW VINYL SIGNAGE ON OH ROLLING GATES

B-05 NEW VINYL WINDOW SIGNAGE

B-07 PREPARE AND PAINT WALL. COLOR = BLACK ABOVE BRICK VENEER, OFFWHITE

ON SIDE WALL TO FIRE STAIRS

B-13 NEW THIN BRICK VENEER, 80 SF, BOD: GLEN-GERY HERITAGE S

AD-ALT SCOPE - PROPOSED

A-02 NEW WOOD GATE WITH NEW CONDENSATE PVC PIPING, PAINTED BLACK

A-03 NEW AC UNIT CAGE

A-04 NEW CONCRETE TOP COAT FOR LEVEL STEPS AND LANDING, BROOM FINISH

A-05 INSTALL NEW TEMPERED GLASS TO FIT WITHIN EXISTING DOOR FRAMING

A-06 PATCH AND REPAIR EXISTING METAL CORNICE. PROVIDE NEW ROOFING AND FLASHING AS NEEDED

SHEET INDEX

SHEET

NUMBER SHEET NAME BI

D S

ET

0/

/2

A000 COVER SHEET ●

A101 EXTERIOR ELEVATIONS ●

A102 EXTERIOR ELEVATIONS - PROPOSED ●

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

GENERAL NOTES:

ALL DRAWINGS ARE TO SCALE AS INDICATED. THE CONTRACTOR MUST

VERIFY THE SCALE BEFORE BEGINNING CONSTRUCTION. DO NOT SCALE

DIRECTLY FROM THE DRAWINGS.

IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN ALL

PERMITS FOR PLUMBING AND ELECTRICAL WORK, AND ANY OTHER WORK

NOT PERMITTED UNDER A GENERAL BUILDING PERMIT.

WORK NOT INDICATED ON A PART OF THE DRAWINGS BUT REASONABLY

IMPLIED TO BE SIMILAR TO THAT SHOWN AT CORRESPONDING PLACES,

SHALL BE REPEATED.

CONTRACTOR SHALL COORDINATE OPENINGS SHOWN ON THE DRAWINGS.

CONTRACTOR SHALL VERIFY AND/OR ESTABLISH ALL EXISTING CONDITIONS

AND DIMENSIONS AT THE SITE.

IF THE EXISTING FIELD CONDITIONS DO NOT PERMIT THE INSTALLATION OF

THE WORK IN ACCORDANCE WITH THE DETAILS SHOWN, THE CONTRACTOR

SHALL NOTIFY THE ARCHITECT IMMEDIATELY AND PROVIDE A SKETCH OF

THE CONDITION WITH CONTRACTOR’S PROPOSED MODIFICATION OF THE

DETAILS GIVEN ON THE CONTRACT DOCUMENTS.

IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND ALL

SUB-CONTRACTORSTO COORDINATE THE WORK AND VERIFY ALL

DIMENSIONS AND INSPECT CONDITIONS OF PRIOR WORK BY ALL TRADES

BEFORE PROCEEDING WITH ANY WORK. UNACCEPTABLE OR INCORRECT

PRIOR WORK SHALL BE REPAIRED OR REPLACED BEFORE STARTING WORK.

PROCEEDING WITH THE WORK SHALL CONSTITUTE ACCEPTANCE OF PRIOR

WORK.

WHERE WORK INVOLVES EXISTING SUPPORTING STRUCTURE, THE

CONTRACTOR SHALL PROVIDE SHORING AND PROTECTION REQUIRED TO

INSURE THE STRUCTURAL INTEGRITY OF THE EXISTING STRUCTURE.

UNLESS SPECIFICALLY SHOWN OR NOTED ON THE DRAWINGS, NO

STRUCTURAL MEMBER SHALL BE CUT, NOTCHED, BORED OR OTHERWISE

MODIFIED WITHOUT THE PERMISSION OF THE STRUCTURAL ENGINEER OF

RECORD

ALL PRODUCTS AND MATERIALS TO BE INSTALLED FOLLOWING

MANUFACTURERS' RECOMMENDATIONS.

CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES IN

THE DOCUMENTS PRIOR TO PROCEEDING WITH ANY WORK INVOLVED.

THE PURPOSE OF THESE DRAWINGS IS FOR THE CONTRACTOR TO INCLUDE

ALL THE LABOR, MATERIALS AND SERVICES REQUIRED FOR THE

COMPLETION OF ALL WORK SHOWN OR REASONABLY IMPLIED BUT NOT

LIMITED TO THAT EXPLICITLY SHOWN IN THE DOCUMENTS.

1.

2.

3.

4.

5.

PROJECT NOTES:

"BASE SCOPE" MEANS THE MINIMUM SCOPE OF WORK. ADDITIONAL SCOPE

MAY BE REQUIRED TO COMPLY WITH CODE, LIFE SAFETY AND STRUCTURAL

REQUIREMENTS.

"AD-ALT SCOPE" MEANS ADDITIONAL AND ALTERNATIVE SCOPE. THE

OWNER HAS THE RIGHT TO INCLUDE OR EXCLUDE ANY OR ALL ITEMS

IDENTIFIED IN THE FINAL SCOPE OF WORK

PAINTING APPLIES TO FIRST LEVEL ONLY UNLESS NOTED OTHERWISE

FOR NEW OR REPLACEMENT GATES, INSTALL SEE-THROUGH GRILLES ONLY

WINDOW DECALS TO HAVE CLEAR BACKGROUNDS RATHER AN OPAQUE

PANELS OR FULL-WINDOW COVERING, TYP.

AD-ALT SCOPE - DEMO

DA-01 DEMOLISH EXISTING WOOD FENCE AND GATE

DA-02 PREPARE STEPS FOR NEW CONCRETE TOP COAT

DA-03 REMOVE EXISTING BROKEN GLASS. PREPARE TO REPLACE

RENDERING: PROPOSED - W MONTGOMERY AVE

EXISTING WALL MOUNTED AIR

CONDITIONING UNIT TO REMAIN

DB-01

DB-02

DA-03

DA-02 A-04

A-03

B-03B-03 B-02B-02

B-07B-07

B-13B-13

B-05B-05

B-07B-07

A-06

A-05

B-05B-05

8' - 7 1/4" V.I.F.

3'

9"

22.8 sf

5.4 sf

3' - 0"

EXISTING WALL MOUNTED

AIR CONDITIONING UNIT TO

REMAIN

DB-02DB-02

DA-03

DA-02

3' - 0"

A-04

B-05B-05

A-03

B-13B-13

B-07B-07

A-05

V.I.F.

4' - 9 1/16"

V.

I.F

/2

6'

6" V

.I.

F.

V.I.F.

2' - 6"

2'

6"

7.3 sf8.3 sf

16.3 sf

.5 sf

.7 sf

WINDOW SIGNAGE ALLOWANCE

PER PHILADELPHIA CODE 14-904

GLASS AREA 22.8+8.3+16.3+7.3+19.8 = 74.5 SF

MAX. SIGNAGE AREA (20%) 15 SF

PROPOSED SIGNAGE AREA 5.4+.7+.5+5.4 = 12 SF - IN COMPLIANCE

SCALE: 1/4" = 1'-0"

1 ELEVATION - 27TH STREET - DEMO

SCALE: 1/4" = 1'-0"

2 ELEVATION - 27TH STREET - PROPOSED

SCALE: 1/4" = 1'-0"

3 ELEVATION - CORNER - DEMO

SCALE: 1/4" = 1'-0"

4 ELEVATION - CORNER - PROPOSED

DRAWN BY:

SCALE:

N O

T

FO

R C

O N

ST

R

UC

TI

O N

PROJECT:

SWRL STUDIO, LLC

2715 Folsom St Philadelphia, PA 19130

©2026

DATE:

PROJECT NO:

NOTES:

swrl studio

NO. DATE DESCRIPTION

ARCHITECT

STRUCTURAL ENGINEER

PRESTON STRUCTURAL SOLUTIONS, LLC

106 Gay Street, Unit 305 Philadelphia, PA 19127

1/4" = 1'-0"

A101 Author

EXTERIOR

ELEVATIONS

1754 N 27th

1754 N 27th St

PHILADELPHIA, PA 19121

10/24/26 2026_02

BASE SCOPE - DEMO

DB-01 UNINSTALL EXISTING FABRIC AWNING. PATCH AND REPAIR WALL @ ANCHOR

LOCATIONS

DB-02 REMOVE REFLECTIVE FILM AND STICKERS AND CLEAN WINDOWS

BASE SCOPE - PROPOSED

B-01 NEW 1/2" PVC WALL SIGNAGE

B-02 PREP & PAINT EXISTING OH ROLLING GATE. INSPECT FOR PROPER FUNCTION.

COLOR = BLACK

B-03 NEW VINYL SIGNAGE ON OH ROLLING GATES

B-05 NEW VINYL WINDOW SIGNAGE

B-07 PREPARE AND PAINT WALL. COLOR = BLACK ABOVE BRICK VENEER, OFFWHITE

ON SIDE WALL TO FIRE STAIRS

B-13 NEW THIN BRICK VENEER, 80 SF, BOD: GLEN-GERY HERITAGE S

AD-ALT SCOPE - PROPOSED

A-02 NEW WOOD GATE WITH NEW CONDENSATE PVC PIPING, PAINTED BLACK

A-03 NEW AC UNIT CAGE

A-04 NEW CONCRETE TOP COAT FOR LEVEL STEPS AND LANDING, BROOM FINISH

A-05 INSTALL NEW TEMPERED GLASS TO FIT WITHIN EXISTING DOOR FRAMING

A-06 PATCH AND REPAIR EXISTING METAL CORNICE. PROVIDE NEW ROOFING AND FLASHING AS NEEDED

AD-ALT SCOPE - DEMO

DA-01 DEMOLISH EXISTING WOOD FENCE AND GATE

DA-02 PREPARE STEPS FOR NEW CONCRETE TOP COAT

DA-01

DA-03

DB-02DB-02

DB-01DB-01

A-03

B-02B-02

B-05B-05

A-03

A-02

B-13B-13

B-07B-07

A-06

EXTENT OF NEW

WALL PAINT

A-05

B-01B-01

9' - 0"

6'

0"

11' - 6"8' - 9 11/16" V.I.F.

3'

9"

19.8 sf

6' - 1"

3'

3"

5.4 sf

WINDOW SIGNAGE ALLOWANCE

PER PHILADELPHIA CODE 14-904

GLASS AREA 22.8+8.3+16.3+7.3+19.8 = 74.5 SF

MAX. SIGNAGE AREA (20%) 15 SF

PROPOSED SIGNAGE AREA 5.4+.7+.5+5.4 = 12 SF - IN COMPLIANCE

DRAWN BY:

SCALE:

N O

T

FO

R C

O N

ST

R

UC

TI

O N

PROJECT:

SWRL STUDIO, LLC

2715 Folsom St Philadelphia, PA 19130

©2026

DATE:

PROJECT NO:

NOTES:

swrl studio

NO. DATE DESCRIPTION

ARCHITECT

STRUCTURAL ENGINEER

PRESTON STRUCTURAL SOLUTIONS, LLC

106 Gay Street, Unit 305 Philadelphia, PA 19127

1/4" = 1'-0"

A102

FC

EXTERIOR

ELEVATIONS -

PROPOSED

1754 N 27th

1754 N 27th St

PHILADELPHIA, PA 19121

10/24/26 2026_02

SCALE: 1/4" = 1'-0"

1 ELEVATION - MONTGOMERY AVE - DEMO

SCALE: 1/4" = 1'-0"

2 ELEVATION - MONTGOMERY AVE - PROPOSED

BASE SCOPE - DEMO

DB-01 UNINSTALL EXISTING FABRIC AWNING. PATCH AND REPAIR WALL @ ANCHOR

LOCATIONS

DB-02 REMOVE REFLECTIVE FILM AND STICKERS AND CLEAN WINDOWS

BASE SCOPE - PROPOSED

B-01 NEW 1/2" PVC WALL SIGNAGE

B-02 PREP & PAINT EXISTING OH ROLLING GATE. INSPECT FOR PROPER FUNCTION.

COLOR = BLACK

B-03 NEW VINYL SIGNAGE ON OH ROLLING GATES

B-05 NEW VINYL WINDOW SIGNAGE

B-07 PREPARE AND PAINT WALL. COLOR = BLACK ABOVE BRICK VENEER, OFFWHITE

ON SIDE WALL TO FIRE STAIRS

B-13 NEW THIN BRICK VENEER, 80 SF, BOD: GLEN-GERY HERITAGE S

AD-ALT SCOPE - PROPOSED

A-02 NEW WOOD GATE WITH NEW CONDENSATE PVC PIPING, PAINTED BLACK

A-03 NEW AC UNIT CAGE

A-04 NEW CONCRETE TOP COAT FOR LEVEL STEPS AND LANDING, BROOM FINISH

A-05 INSTALL NEW TEMPERED GLASS TO FIT WITHIN EXISTING DOOR FRAMING

A-06 PATCH AND REPAIR EXISTING METAL CORNICE. PROVIDE NEW ROOFING AND FLASHING AS NEEDED

AD-ALT SCOPE - DEMO

DA-01 DEMOLISH EXISTING WOOD FENCE AND GATE

DA-02 PREPARE STEPS FOR NEW CONCRETE TOP COAT

A000 - COVER SHEET
A101 - EXTERIOR ELEVATIONS
A102 - EXTERIOR ELEVATIONS - PROPOSED

File details come from the government source that posted it. Updated .