BRIDGE INSPECTION REPORT
PINEHURST BRANCH BRIDGE
BEACH DRIVE OVER PINEHURST BRANCH
ROCK CREEK PARK
LN
STRUCTURE NO. 3450-030P
INSPECTION TYPE: ROUTINE
INSPECTION DATE: 6/11/13
Federal Highway Administration
Report prepared by: WU
MILE POINT:
KILOMETER POINT:
0.00 0.00
Federal Lands Bridge Office Bridge Inspection and Management Program 21400 Ridgetop Circle Sterling, Virginia 20166 http://www.efl.fhwa.dot.gov/FLHBO/BIP
STRUCTURE SUMMARY STRUCTURE NO. 3450-030P
PINEHURST BRANCH BRIDGE INSPECTION DATE: 6/11/13
BRIDGE IDENTIFICATION AND DESCRIPTION
MAIN SPAN MATERIAL: ....... CONCRETE NO. OF MAIN SPANS:
MAIN SPAN TYPE: ............... ARCH - DECK NO. OF APPR. SPANS:
# OF BEAMS, MAIN SPAN: .. 1 STRUCT. TOTAL LENGTH: .. 16.0 FT (4.9 M)
DECK TYPE: ......................... NOT APPLICABLE MAX. SPAN LENGTH: .......... 16.0 FT (4.9 M) WEARING SURFACE: .......... NOT APPLICABLE DECK WIDTH: ...................... 35.5 FT (10.8 M) ABUT. FOUNDATIONS: ........ SPREAD FTG ON BEARING MAT'L CURB TO CURB WIDTH: ..... 21.0 FT (6.4 M)
PIER FOUNDATION(S): ........ N/A YEAR BUILT:
ABUTMENT / PIER MAT'L: ... CONCRETE YEAR RECONSTRUCTED: .. N/A
PROJ./PLAN REF. NO: ......... 202(1) / 0000000000 SKEW ANGLE: ..................... 0 °
NPS ROAD CLASS: .............. 1 - PRINCIPAL PARK ROAD FRACTURE CRITICAL: ........ N/A STRUCTURE HISTORY: ...... 2000-DOWNSTREAM SPANDREL WALL REBUILT, STEEL ARCH REPAINTED.
LOCATION
ROCK CREEK PARK MILE POINT: ..................... 0.00 (KM PT 0.00)
STATE: ................................. DISTRICT OF COLUMBIA LOCATION: 0.2 MILES SOUTH OF SHERRILL DRIVE
FACILITY CARRIED: ............ BEACH DRIVE
FEATURE INTERSECTED: .. PINEHURST BRANCH
STRUCTURE EVALUATION SUMMARY
This concrete and steel deck arch bridge is in fair condition overall. The steel portion of the arch continues to rust along the top of the footings and along the seam, with up to 100% loss of section on the plates and hardware. This condition should be repaired in order to arrest further rusting and section loss.
Other problems include minor outward rotation of the west spandrel wall at the north end, moderate spalling of the exposed portions of the concrete footing for the steel arch, severe deterioration of the vertical joint filler between the northwest wingwall and the west spandrel wall, channel bank erosion, and moderate scour along the south abutment as a result of the poor channel alignment. The rotation of the west spandrel will continue to be monitored during future inspections.
Repairs should be made as outlined in this report to prevent the possible development of more serious or costly problems in the future. If corrective action is not taken, the deterioration will likely continue to progress and may eventually lead to loss of load capacity.
INSPECTION TEAM: E. DUES, C. MARBURGER (GANNETT FLEMING)
CONDITION ASSESSMENT:
ERIC DUES, PE, FIELD TEAM LEADER
REPORT REVIEW :
MARCUS MILLER, P.E., SENIOR INSPECTION ENGINEER 703-404-6252
REPORT APPROVAL: DATE: 10/31/13
JORGOMAI CEESAY, PH.D., P.E., BIP SUPERVISORY ENGINEER 703-404-6244
RECOMMENDATIONS AND ESTIMATED COSTS STRUCTURE NO. 3450-030P
A (Critical) - Structure is closed, in imminent danger of collapse, or presents a critical safety hazard.
B (Major) - Structure is seriously deficient or presents a safety hazard, but can remain in service at reduced loads or with frequent inspections.
C (Moderate) - Structure is deficient, functionally obsolete, or requires substantial repairs to prevent a serious deficiency or unsafe condition.
D (Minor) - Structure is generally in good condition. Preventative maintenance may be required.
E (Special) - Structure is under construction or reconstruction.
C226 PRIORITY OF IMPROVEMENT
ITEM
NO.
MAINTENANCE RECOMMENDATIONS
(GENERALLY NOT FLHP ELIGIBLE)
QTY. UNIT COST
UNIT
ESTIMATE
COST
PRELIM.
PRELIM. MAINTENANCE TOTAL : $115,000
ITEM
NO.
REHABILITATION/RECONSTRUCTION
(TYPICALLY NEEDED WITHIN 5 YEARS)
QTY. UNIT
UNIT
COST ESTIMATES
PRELIM. COST
REHAB. RECONSTR.
PRELIM. REHABILITATION/RECONSTRUCTION TOTAL :
COST ESTIMATE SUMMARY
PRELIM. MAINTENANCE TOTAL:
PRELIM. REHABILITATION TOTAL:
PRELIM. RECONSTRUCTION TOTAL:
TOTAL ITEMIZED COSTS:
PRELIMINARY ESTIMATE TOTAL* :
(*Includes typical contract costs for mobilization, traffic control, and design/construction engineering; but does not include detour bridges, work beyond the bridge limits, or work not listed above. Estimates are approximate and are for preliminary planning purposes only; they should not be used as a complete or final engineers estimate.)
REMARKS:
FIELD INSPECTION REPORT STRUCTURE NO. 3450-030P
G = GOOD (CODES 7 - 9) F = FAIR (CODES 5 - 6) P = POOR (CODES 0 - 4)
CONDITION RATING CODE EQUIVALENTS FOR SUB-ELEMENTS
SERIOUS CONDITION - loss of section, deterioration, spalling, or scour have seriously affected primary structural components. Local failures are possible.
Fatigue cracks in steel or shear cracks in concrete may be present.
CRITICAL CONDITION - advanced deterioration of primary structural elements. Fatigue cracks in steel or shear cracks in concrete may be present or scour may have removed substructure support. Unless closely monitored it may be necessary to close the structure until corrective action can be taken.
“IMMINENT” FAILURE CONDITION - major deterioration or section loss present in critical structural components or obvious vertical or horizontal movement affecting structure stability. Structure is closed to traffic but corrective action may return structure to light service.
FAILED CONDITION - out of service; beyond corrective action.
CONDITION RATING CODES FOR ITEMS 58 - 62, 222, 223
NOT APPLICABLE
EXCELLENT CONDITION
VERY GOOD CONDITION - no problems noted.
GOOD CONDITION - some minor problems.
SATISFACTORY CONDITION - structural elements show some minor deterioration.
FAIR CONDITION - all primary structural elements are sound but may have minor section loss, cracking, spalling, or scour.
POOR CONDITION - advanced section loss, deterioration, spalling, or scour.
N
58. DECK
ITEM REFERENCE AND REMARKS
OTHER
ALIGNMENT
DEFLECTION AND/OR VIBRATION
FASCIA(E)
DIAPHRAGMS AND BRACING
TRUSSES
FLOOR BEAMS AND STRINGERS
ARCH(ES) OR SLAB(S)
GIRDERS OR BEAMS
BEARING DEVICES
59. SUPERSTRUCTURE
OTHER
DEFLECTION AND/OR VIBRATION
UTILITIES
DRAINS AND DRAINAGE
PARAPETS AND/OR RAILINGS
CURBS, SIDEWALKS, AND MEDIAN
RIDEABILITY
WEARING SURFACE
EXPANSION JOINTS
DECK SLAB
OTHER
SETTLEMENT OR DEFLECTION
EROSION AND/OR SCOUR
FOUNDATIONS
CAPS AND/OR BEARING SEATS
PILE BENTS
WALLS AND/OR COLUMNS
PIER(S)
OTHER
SLOPE PROTECTION
SETTLEMENT OR DEFLECTION
EROSION AND/OR SCOUR
EXPANSION JOINTS
WEEP HOLES
WINGWALLS
FOUNDATIONS
BACKWALLS AND/OR BULKHEADS
CAPS AND/OR BEARING SEATS
PILE BENTS
BREASTWALLS OR COLUMNS
ABUTMENTS
60. SUBSTRUCTURE
1.
10.
2.
3.
4.
5.
6.
7.
8.
9.
10.
9.
8.
7.
6.
5.
4.
3.
2.
1.
PAINT
11.
N
N N F N N N N F G
F G
(VEGETATION)
N N N N F G N F F G N N
N N N N N N N
11.
10.
9.
8.
7.
6.
5.
4.
3.
2.
1.
12.
13.
14.
15.
16.
17.
18.
19.
(CONCRETE FTG)
58.3, 222.4 MINOR LONGITUDINAL CRACK ALONG CENTERLINE OF ROADWAY.
MINOR RANDOM CRACKING THROUGHOUT. LARGE ASPHALT
PATCHES IN NORTHBOUND LANE, BOTH APPROACHES. NORTH
APPROACH (BOTH LANES) PATCHED WITH ASPHALT.
58.5 MINOR TRANSVERSE CRACKING THROUGHOUT SIDEWALK;
BROKEN AT NORTH END DUE TO SETTLEMENT. SEE 222.6. MINOR
SPALL IN WEST GUTTER NEAR SOUTH END OF BRIDGE.
58.6, 222.3 MINOR CHECKING OF TIMBER RAILING AND APPROACH
GUARDRAILS.
59.3,8 MINOR CRACKING WITH EFFLORESCENCE AND MINOR POPOUTS
WITH EXPOSED REBAR ON CONCRETE (WEST) PORTION OF ARCH
UNDERSIDE. HEAVY EFFLORESCENCE ON UNDERSIDE OF RING
STONES AT WEST SIDE. MINOR TO MODERATE FRACTURING OF
RING STONES ON WEST SIDE NEAR SOUTH END.
MODERATE EFFLORESCENCE ON WEST SPANDREL WALL NEAR
NORTH END. NORTH END OF WEST SPANDREL WALL ROTATED
OUT 3", MEASURED AT TOP. MODERATE VEGETATION
OVERHANGING WEST SPANDREL WALL.
MODERATE TO SEVERE RUSTING THROUGHOUT STEEL (EAST)
PORTION OF ARCH, WITH UP TO 100% SECTION LOSS ON PLATES
AND HARDWARE, ESPECIALLY ALONG TOP OF FOOTINGS AND
ALONG SEAM.
59.11 MODERATE VEGETATION GROWTH ALONG UPSTREAM SIDE OF
STRUCTURE. LARGE TREE NEAR SLOPE OF UPSTREAM
EMBANKMENT.
60.5 MODERATE SPALLING OF EXPOSED PORTIONS OF CONCRETE
FOOTINGS FOR STEEL PORTION OF ARCH.
60.6 MINOR CRACKING WITH EFFLORESCENCE ON WINGWALLS. DRY
STACKED STONE WINGWALL AT NORTHWEST CORNER APPEARS
STABLE.
G G G G G N
N
N
N
N
FIELD INSPECTION REPORT STRUCTURE NO. 3450-030P
ITEM REFERENCE AND REMARKS
STREAM BED COMPOSITION : 9.
AVERAGE CLEAR OPENING 8.
NORMAL VELOCITY 7.
ADEQUACY OF OPENING 6.
OTHER 5.
WATERWAY OBSTRUCTIONS 4.
CHANNEL PROTECTION3.
EROSION AND/OR SCOUR2.
ALIGNMENT1.
61. CHANNEL 5
P F G G
F(SPILLWAY)
LOW
SUFF
5 FT.
SAND, SILT
222. APPROACHES 6
OTHER 9.
ALIGNMENT 8.
SIGNS7.
SETTLEMENT 6.
EROSION5.
SURFACING4.
APPROACH GUARDRAIL 3.
2. RELIEF JOINTS
APPROACH SLABS1. N
N G F G G N G N
223. RETAINING WALL N
OTHER 6.
SETTLEMENT OR DEFLECTION5.
EROSION AND/OR SCOUR4.
FOUNDATION3.
WEEP HOLES2.
1. WALL
36. TRAFFIC AND SAFETY FEATURES
APPROACH GUARDRAIL ENDSD.
APPROACH GUARDRAILSC.
TRANSITIONSB.
BRIDGE RAILINGSA. 0
TRAFFIC SAFETY RATING CODES
0 - Does not meet standards or a safety feature is required and none is provided.
1 - Meets currently acceptable standards.
N - Not applicable or a safety feature is not required.
60.8 SEVERE DETERIORATION OF VERTICAL JOINT FILLER BETWEEN
NORTHWEST WINGWALL AND WEST SPANDREL WALL; MINOR
ELSEWHERE.
60.9 MODERATE SCOUR ALONG SOUTH ABUTMENT WITH FOOTING
EXPOSED UP TO 12"H IN CONCRETE PORTION AND UP TO 24"H IN
STEEL PORTION. MODERATE SCOUR HOLE AT UPSTREAM END OF
NORTH ABUTMENT, UP TO 2'D; MINOR AT DOWNSTREAM END OF
SOUTH ABUTMENT, UP TO 1'D. MODERATE EROSION ALONG
WINGWALLS.
61.1 CHANNEL FLOWS DIRECTLY INTO SOUTH ABUTMENT CAUSING
SCOUR (SEE 60.9).
61.2,3 MINOR TO MODERATE EROSION OF CHANNEL BANKS AT
STRUCTURE.
61.4 MODERATE ACCUMULATION OF SILT AND SEDIMENT IN CHANNEL
UNDER STRUCTURE AGAINST NORTH ABUTMENT.
61.5 PREVIOUSLY NOTED MODERATE SCALING OF SPILLWAY ON
DOWNSTREAM SIDE OF STRUCTURE COULD NOT BE VERIFIED
DURING THIS INSPECTION. MINOR SCOUR OF SPILLWAY WITH
APPROXIMATELY 2" OF UNDERMINING (COULD NOT BE VERIFIED
DURING THIS INSPECTION).
222.5 SIDEWALK UNDERMINED (1-1/2'L X 4"H X 1-1/2' UNDER) AT NORTH
END.
222.6 1-1/2" SETTLEMENT OF SIDEWALK NEAR NORTH END.
36.A,C GUARDRAIL HEIGHT OF 1'-10" DOES NOT MEET AASHTO MINIMUM
HEIGHT REQUIREMENT OF 2'-3" FOR TRAFFIC BARRIERS.
STRUCTURE LOAD RATING STRUCTURE NO. 3450-030P
TRUCK TYPE
INVENTORY RATING (NORMAL TRAFFIC) OPERATING RATING (MAXIMUM LOAD)
TONS METRIC TONS TONS METRIC TONS
H 15 14 20 18
HS 27 24 37 34
TYPE 3 23 21 31 28
TYPE 3S2 36 33 50 45
TYPE 3-3 45 41 61 55
DESIGN LOADING: UNKNOWN (H15 ASSUMED - SEE REMARKS)
X CAPACITY MEETS OR EXCEEDS DESIGN LOAD
CAPACITY IS LESS THAN DESIGN LOAD
ORIGINAL LOAD RATING CALCULATION APPLICABLE
ORIGINAL LOAD RATING CALCULATION REVISED
DATE OF LOAD RATING CALCULATION:
LOAD RATING CONTROLLED BY:
REMARKS: DESIGN LOADING IS UNKNOWN; ASSUMPTION IS BASED ON STRUCTURE TYPE, LOCATION, AGE AND
CONDITION.
A
A
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 3450-030P
PINEHURST BRANCH BRIDGE INSPECTION DATE: 6/11/13
STRUCTURE IDENTIFICATION
(201) PARK: ROCK CREEK PARK (1) STATE: ....................................... 113 - DISTRICT OF COLUMBI
(202) STRUCTURE NAME: .......... PINEHURST BRANCH BRIDGE (2) STATE HWY. AGENCY DIST:
(203) STRUCTURE KIND: ............ 1 - BRIDGE (3) COUNTY CODE: ........................ 001 - DISTRICT OF COLUMBI
(204) STRUCTURE NUMBER: ..... 3450-030P (4) CITY/PLACE CODE:
(205) NPS REGION: .................... 2 - NATIONAL CAPITAL (5) INVENTORY ROUTE:
(206) ROUTE CODE NUMBER: ... 10 (6) FEATURES INTERSECTED:....... PINEHURST BRANCH
(207) ROAD SECTION NO: .......... 030P (7) FACILITY CARRIED: .................. BEACH DRIVE
(208) NPS ROAD CLASS: ............ 1 - PRINCIPAL PARK ROAD (8) STATE STRUCTURE NO: .......... 3450030P0000000
(209) WITHIN NPS BNDRY?: ....... YES (9) LOCATION: ................................ 0.2 MILES SOUTH OF SHERR
(210) OPERATING UNIT: ............. PARK (10) INV. RTE. - MIN. VERT. CLR: .. 99.99 FT (99.99 M)
(211) PROJECT NO(S): ................ 202(1) (11) MILE POINT: ............................. 0.00 (KM PT 0.00)
(212) DRAWING NUMBERS: ....... 0000000000 (27) YEAR BUILT:
(21) MAINTAINED BY: ................. 66 - NATIONAL PARK SERVICE (106) YEAR RECONSTRUCTED: .... N/A
(22) OWNER: ............................... 66 - NATIONAL PARK SERVICE (20) TOLL: ........................................ 3 - FREE ROAD
(37) HISTORICAL DESIGNATION: .. 5 - NOT ELIGIBLE
STRUCTURE DESCRIPTION, FOUNDATION, AND DECK TYPE
(43A) MAIN STR. MATERIAL: ..
(43B) MAIN STR. TYPE:
(45) NO. OF MAIN SPANS:
(48) MAX. SPAN LENGTH:
(49) STRUCTURE LENGTH:
(216A) ABUTMENT #1 FDN:
(216B) ABUTMENT #2 FDN:
(217A) PREDOM. PIER FDN.: ..
(217B) SECOND. PIER FDN: ...
(107) DECK TYPE:
1 - CONCRETE
11 - ARCH - DECK
16.0 FT (4.9 M)
16.0 FT (4.9 M)
2 - SPREAD FTG ON BEARING MAT'L
2 - SPREAD FTG ON BEARING MAT'L
6 - N/A
6 - N/A
N - NOT APPLICABLE
(44A) APPR. STR. MATERIAL: ........ 0 - OTHER
(44B) APPR. STR. TYPE: ................ 00 - OTHER
(46) NO. OF APPROACH SPANS: .. 0
(108) WEAR SURFACE/PROTECT SYSTEM:
A) TYPE WEARING SURFACE: .. N - NOT APPLICABLE
B) TYPE MEMBRANE: ................. N - NOT APPLICABLE
C) TYPE PROTECTION: .............. N - NOT APPLICABLE
(218) IS SALT USED?: ..................... YES
LOAD RATING AND POSTING
(31) DESIGN LOAD: ................. 0 - UNKNOWN (41) LOAD RESTRICTION: ......... A - OPEN, NO RESTRICTION
(66) INVENTORY RATING: ...... 27.0 TONS (24.0 METRIC TONS) (70) BRIDGE POSTING: .............. 5 - NO POSTING REQUIRED
(64) OPERATING RATING: ...... 37.0 TONS (34.0 METRIC TONS)
INSPECTION DATES
(90) INSPECTION DATE: 6/13 (91) FREQ. OF INSP: 24 MONTHS (92 / 93) CRITICAL FEATURE INSPECTION (CFI):
(219) ADD. STUDIES NEEDED: N - 0 - NONE (A) FRACTURE CRITICAL: ... NO
INSP. EVERY: MONTHS - LAST INSP. : (220) SPECIAL STUDY TYPE: 0 - NONE
(B) UNDERWATER: .............. NO
(221) SPECIAL STUDY DATE: INSP. EVERY: MONTHS - LAST INSP. :
(C) SPECIAL INSPECTION: .. NO
INSP. EVERY: MONTHS - LAST INSP. :
f
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 3450-030P
PINEHURST BRANCH BRIDGE INSPECTION DATE: 6/11/13
GEOMETRY, TRAFFIC, AND NAVIGATIONAL DATA
(16) LATITUDE: ............................. 38°58'16.30"
(17) LONGITUDE: ......................... 77°02'37.70"
(19) DETOUR LENGTH: ............... 2 MI (3 KM)
(28A) LANES ON STRUCT:
(28B) LANES UNDER STRUCT: ... 00
(42A) SERVICE ON: ..................... 5 - HIGHWAY-PEDESTRIAN
(42B) SERVICE UNDER: .............. 5 - WATERWAY
(29) AVG. DAILY TRAFFIC:
(30) YEAR OF ADT:
(114) FUTURE ADT:
(115) YEAR OF FUTURE ADT:
(101) PARALLEL STRUCTURE: ... N - NONE
(38) NAVIGATION CONTROL?: ... 0
(39) VERTICAL CLEARANCE: ...... 0.0 FT (0.0 M)
(40) HORIZ. CLEARANCE: ........... 0.0 FT (0.0 M)
(111) ABUT. OR PIER PROT:
LATERAL UNDERCLEARANCE:
(55) RIGHT: ....................... 0.0 FT (0.0 M)
(56) LEFT: ......................... 0.0 FT (0.0 M)
(51) CURB TO CURB WIDTH: ........... 21.0 FT (6.4 M)
(52) DECK WIDTH: ............................ 35.5 FT (10.8 M)
(32) APPR. ROADWAY WIDTH: ........ 28.0 FT (8.5 M)
(213) APPR. PAVEMENT WIDTH: ..... 21.0 FT (6.4 M)
LEFT SHOULDER: .................. 1.0 FT (0.3 M)
RIGHT SHOULDER: ................ 6.0 FT (1.8 M)
(33) BRIDGE MEDIAN: ....................... 0 - NO MEDIAN
(34) SKEW ANGLE: ............................ 0 °
(35) DECK FLARE?: ........................... NO
(47) TOTAL HORIZ. CLEARANCE: .... 21.0 FT (6.4 M)
(50) SIDEWALKS:
LEFT : ...................................... 0.0 FT (0.0 M)
RIGHT : ................................... 5.0 FT (1.5 M)
(214) BRIDGE RAIL TYPE:
RAIL CONFIGURATION: ......... 1 - FULL HEIGHT (NO PARAPE
MATERIAL: .............................. 8 - TIMBER/OTHER
DESIGN TYPE: ........................ 3 - SIMPLE RAIL (joints at each
(215) BRIDGE RAIL HEIGHT: ............ 1.83 FT (0.56 M)
(53) MIN. VRT. CLEAR. OVER DECK: 99.99 FT (99.99 M)
(54) MIN. VRT. UNDERCLEARANCE: 0.00 FT (0.00 M)
CONDITION AND APPRAISAL DATA, PROPOSED IMPROVEMENTS, AND COST
(58) DECK: ................................. N
(59) SUPERSTRUCTURE:
(60) SUBSTRUCTURE:
(61) CHANNEL:
(62) CULVERT: ........................... N
(222) APPROACHES:
(223) RETAINING WALL: ........... N
(36) TRAFFIC SAFETY FEAT: ... 0101
(75A) TYPE OF WORK:
(75B) WORK DONE BY:
(76) IMPROVEMENT LENGTH: ..
(67) STRUCTURAL EVALUATION:
(68) DECK GEOMETRY:
(69) UNDERCLEARANCES:
(71) WATERWAY ADEQUACY:
(72) APPROACH ALIGNMENT:
(113) SCOUR CRITICAL:
(225) PURPOSE OF IMPROVEMENT:
(226) PRIORITY OF IMPROVEMENT:
(227) MAINTENANCE COST:
(228) REHAB./RECONSTR. COST: ...
(229) CONSTRUCTION COST:
N
5 - Stable; scour within limits of
1 - MAINTENANCE
C - MODERATE
ADDITIONAL INFORMATION
(230) STRUCTURE HISTORY:
2000-DOWNSTREAM SPANDREL WALL REBUILT, STEEL ARCH REPAINTED.
(231) ADDITIONAL CONSIDERATIONS:
(330) ADDITIONAL CONFIG. INFO.:
http:77�02'37.70 http:38�58'16.30
APPENDIX STRUCTURE NO. 3450-030P
PHOTOGRAPHS STRUCTURE NO. 3450-030P
FLOW
PHOTO #1 - LOOKING SOUTH TOWARD BINGHAM DRIVE
PHOTO #2 - EAST (DOWNSTREAM) SIDE; NOTE HIGH BACKWATER
FROM ROCK CREEK HAS OVERTOPPED SPILLWAY
PHOTO #3 - GENERAL TOPSIDE VIEW LOOKING SOUTH
PHOTO #4 - TYPICAL RANDOM CRACKING OF PAVEMENT;
SOUTHBOUND LANE SHOWN
PHOTO #5 - TYPICAL CHECKING OF TIMBER
GUARDRAIL; WEST GUARDRAIL SHOWN
PHOTO #6 - CRACKING OF SIDEWALK AT
NORTH END; NOTE SIDEWALK BROKEN DUE
TO SETTLEMENT
PHOTO #7 - EAST SIDEWALK UNDERMINED AT
NORTH END
PHOTO #8 - ROTATION OF WEST SPANDREL
WALL AT NORTH END
PHOTO #9 - GENERAL UNDERSIDE VIEW
LOOKING EAST, CONCRETE PORTION
PHOTO #10 - TYPICAL EFFLORESCENCE ON
UNDERSIDE OF RING STONES AT WEST SIDE;
NORTH END SHOWN
PHOTO #11 - GENERAL UNDERSIDE VIEW LOOKING WEST, STEEL
PORTION
PHOTO #12 - TYPICAL RUSTING OF ARCH WITH SECTION LOSS ON
PLATES AND HARDWARE; NORTH SIDE SHOWN
PHOTO #13 - CLOSE UP OF PREVIOUS
PICTURE; NOTE SEVERE CORROSION OF
SEAM
PHOTO #14 - GENERAL VIEW OF SOUTH
ABUTMENT
PHOTO #15 - VEGETATION ALONG UPSTREAM
SIDE OF STRUCTURE
PHOTO #16 - TYPICAL EFFLORESCENCE ON
WINGWALLS; NORTHWEST WINGWALL
SHOWN; ALSO NOTE DETERIORATION OF
VERTICAL JOINT FILLER
PHOTO #17 - PREVIOUSLY NOTED SOUTH ABUTMENT FOOTING
EXPOSED NOT VISIBLE DUE TO HIGH WATER
PHOTO #18 - TYPICAL SPALLING OF EXPOSED PORTIONS OF
CONCRETE FOOTING FOR STEEL PORTION OF ARCH; EAST END OF
NORTH ABUTMENT SHOWN
PHOTO #19 - SCOUR AT DOWNSTREAM END OF SOUTH ABUTMENT
PHOTO #20 - LOOKING UPSTREAM THROUGH STRUCTURE
PHOTO #21 - TYPICAL EROSION OF CHANNEL BANKS; SOUTH
UPSTREAM CHANNEL BANK SHOWN
PHOTO #22 - LOOKING DOWNSTREAM THROUGH STRUCTURE
PHOTO #23 - PREVIOUSLY NOTED SCALING OF CONCRETE ON
SPILLWAY NOT VISIBLE DUE TO HIGH WATER