Drawings_Part6.pdf
PDF 9 MB Posted
- Attached to
- Upgrade Doors and Hardware - Iowa City VAMC
- Solicitation number
- 36C26325B0015_1
About this file
These construction documents detail a door and door hardware upgrade project for the Iowa City VA Health Care System, involving multiple buildings (Buildings 1, 2, 7, and 50). The project encompasses comprehensive demolition plans and floor plans across basement, first, and second levels, with specific focus on removing and replacing existing doors, frames, hardware, operators, motion sensors, and hinges. Detailed demolition legends and wall rating classifications are provided, indicating careful consideration of fire barriers, smoke partitions, and corridor wall ratings. The documents, prepared by Fourfront Design, Inc. and dated August 28, 2024, are at the construction documents phase and include precise architectural drawings with 1/16" and 1/4" scale measurements, highlighting specific door modification requirements for each identified door across the healthcare facility's complex infrastructure.
View the file
Other files
Show all 31
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DN
DN
UP
UP
C
A
AD1.12
AD1.12
AD1.12
DOOR 1C03
DOOR 113A
DOOR 113
DOOR 103
AD1.12
1. SHEET SIZE FOR PROPER SCALE IS 42X30. CONTRACTOR SHALL NOT
SCALE DRAWINGS BUT SHALL REQUEST THE DESIRED DIMENSIONS FROM
THE ARCHITECT.
2. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VISIT THE
PROJECT AND VERIFY EXISTING CONDITIONS/DIMENSIONS AND
PROPOSED CONDITIONS. COORDINATE DEMOLITION BETWEEN ALL
TRADES. NOTIFY A/E IMMEDIATELY OF ANY CONFLICTS OR
DISCREPANCIES.
3. SEE ENLARGED AREA PLANS FOR KEYNOTES.
4. EXISTING AREAS NOT IN CONTRACT SHOWN SHADED FOR CLARITY.
POINT OF EGRESS
SHEET LEGEND:
NORTH ARROW
PLAN NORTH
TRUE NORTH
FOURFRONT DESIGN, INC.
517 7TH STREET
RAPID CITY, SOUTH DAKOTA 57701
PH: (605) 342-9470
FAX: (605) 342-2377
WWW.FOURFRONTDESIGN.COM
FOUR FRONT
D E S I G N I N C.
Project Number
Building Number
Drawing Number
Dwg.
DrawnCheckedDate
Location
Project TitleDrawing Title
COR / Project Engineer
CONSULTANTS:
DateRevisions:
VA FORM 08-6231
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 of
Office of Construction and Facilities Management
Department of Veterans Affairs
Phase
STAMP: ARCHITECT/ENGINEER OF RECORD:
4F PROJECT NO: 19.2481.A26 40
/2 /2
:2
:5
P M
8/28/2024
DEMOLITION PLAN - BUILDING 2,
FLOOR 1 PLAN
AD1.09
UPGRADE DOORS/DOOR
HARDWARE AT IOWA CITY VA
HEALTH CARE SYSTEM
JEKP
IOWA CITY, IOWAMATTHEW RUPPENKAMP
CONSTRUCTION
DOCUMENTS
636A8-23-102
CONSTRUCTION DOCUMENTS1/8" = 1'-0"
BUILDING 2, FLOOR 1 DEMO PLAN
GENERAL NOTES:
1. SHEET SIZE FOR PROPER SCALE IS 42X30. CONTRACTOR SHALL NOT
SCALE DRAWINGS BUT SHALL REQUEST THE DESIRED DIMENSIONS FROM
THE ARCHITECT.
2. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VISIT THE
PROJECT AND VERIFY EXISTING CONDITIONS/DIMENSIONS AND
PROPOSED CONDITIONS. COORDINATE DEMOLITION BETWEEN ALL
TRADES. NOTIFY A/E IMMEDIATELY OF ANY CONFLICTS OR
DISCREPANCIES.
3. SEE ENLARGED AREA PLANS FOR KEYNOTES.
4. EXISTING AREAS NOT IN CONTRACT SHOWN SHADED FOR CLARITY.
-7 AD1.12
DOOR 03-7
POINT OF EGRESS
SHEET LEGEND:
NORTH ARROW
PLAN NORTH
TRUE NORTH
FOURFRONT DESIGN, INC.
517 7TH STREET
RAPID CITY, SOUTH DAKOTA 57701
PH: (605) 342-9470
FAX: (605) 342-2377
WWW.FOURFRONTDESIGN.COM
FOUR FRONT
D E S I G N I N C.
Project Number
Building Number
Drawing Number
Dwg.
DrawnCheckedDate
Location
Project TitleDrawing Title
COR / Project Engineer
CONSULTANTS:
DateRevisions:
VA FORM 08-6231
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 of
Office of Construction and Facilities Management
Department of Veterans Affairs
Phase
STAMP: ARCHITECT/ENGINEER OF RECORD:
4F PROJECT NO: 19.2481.A26 40
/2 /2
:2
:5
P M
8/28/2024
DEMOLITION PLAN - BUILDING 7
FLOOR PLANS
AD1.10
UPGRADE DOORS/DOOR
HARDWARE AT IOWA CITY VA
HEALTH CARE SYSTEM
JEKP
IOWA CITY, IOWAMATTHEW RUPPENKAMP
CONSTRUCTION
DOCUMENTS
636A8-23-102
CONSTRUCTION DOCUMENTS
GENERAL NOTES:
1/8" = 1'-0"
BUILDING 7 DEMO PLAN
BE24
02-11
02-1402-21
02-20
02-11
B E
02-1202-20
02-21
B E
02-12
02-20
02-21
B W
A
02-12
02-20
02-21
02-11 02-11
1. SHEET SIZE FOR PROPER SCALE IS 42X30. CONTRACTOR SHALL NOT
SCALE DRAWINGS BUT SHALL REQUEST THE DESIRED DIMENSIONS FROM
THE ARCHITECT.
2. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VISIT THE
PROJECT AND VERIFY EXISTING CONDITIONS/DIMENSIONS AND
PROPOSED CONDITIONS. COORDINATE DEMOLITION BETWEEN ALL
TRADES. NOTIFY A/E IMMEDIATELY OF ANY CONFLICTS OR
DISCREPANCIES.
3. SEE ENLARGED AREA PLANS FOR KEYNOTES.
4. EXISTING AREAS NOT IN CONTRACT SHOWN SHADED FOR CLARITY.
02-1102-11
02-14
B C
W
02-20
02-21
BS04
02-20
02-21
02-11
02-14
B W
02-1102-11
02-14
BCS03B
02-1102-11
02-14
02-23
B W
02-1102-11
02-14
02-23
B W
C
02-11
02-14
02-20
B W
02-11
02-14
02-20
02-21
02-11
B W
02-11
02-14
02-2102-21
02-11
B C
02-11
02-20
02-21
02-22
02-11
1E06
02-11
02-14
02-20
02-21
02-11
1CN01A
1CN01
02-11
02-14
02-11
02-21
02-20
02-20
02-21
C
N
02-14
02-1102-11
02-27
02-0302-03
02-11
02-14
W
02-24
02-11
TEMPORARY PARTITION
DEMOLITION LEGEND:
PLAN NORTH
TRUE NORTH
NORTH ARROW
1-HOUR FIRE BARRIER
WALL RATING LEGEND:
2-HOUR FIRE BARRIER
SMOKE BARRIER
2-HOUR FIRE SMOKE
BARRIER
FIRE RATING
SMOKE AND FIRE RATING
1-HOUR FIRE SMOKE
BARRIER
SMOKE PARTITION
SMOKE RESISTIVE
CORRIDOR WALL
1C07
02-14
02-1102-11
02-14
02-11
02-11
1CW07
02-24
02-11
02-11
02-14
1W501CW07A
02-24 02-24
50C101
02-14
02-11
02-11
1CN03A
02-11
02-14
FOURFRONT DESIGN, INC.
517 7TH STREET
RAPID CITY, SOUTH DAKOTA 57701
PH: (605) 342-9470
FAX: (605) 342-2377
WWW.FOURFRONTDESIGN.COM
FOUR FRONT
D E S I G N I N C.
Project Number
Building Number
Drawing Number
Dwg.
DrawnCheckedDate
Location
Project TitleDrawing Title
COR / Project Engineer
CONSULTANTS:
DateRevisions:
VA FORM 08-6231
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 of
Office of Construction and Facilities Management
Department of Veterans Affairs
Phase
STAMP: ARCHITECT/ENGINEER OF RECORD:
4F PROJECT NO: 19.2481.A26 40
/2 /2
:2
:5
P M
8/28/2024
DEMOLITION PLANS - ENLARGED
AD1.11
UPGRADE DOORS/DOOR
HARDWARE AT IOWA CITY VA
HEALTH CARE SYSTEM
JEKP
IOWA CITY, IOWAMATTHEW RUPPENKAMP
CONSTRUCTION
DOCUMENTS
636A8-23-102
CONSTRUCTION DOCUMENTS
1/4" = 1'-0"
BUILDING 1 - DOOR BE24 - ENLARGED PLAN - DEMO
1/4" = 1'-0"
BUILDING 1 - DOOR BE01 - ENLARGED PLAN - DEMO
1/4" = 1'-0"
BUILDING 1 - DOOR BE00 - ENLARGED PLAN - DEMO
1/4" = 1'-0"
BUILDING 1 - DOOR BW12A - ENLARGED PLAN - DEMO
02-03 REMOVE EXISTING CEILING AS NEEDED DUE TO RELOCATED DOOR.
02-11 PROVIDE AND INSTALL TEMPORARY VESTIBULE TO SEPERATE AREAS
OF CONSTRUCTION ACTIVITY FROM ADJACENT AREAS THAT WILL
REMAIN OCCUPIED AND OPERATIONAL.
02-12 FRAME MAY NEED TO BE SAW CUT FROM THE CONCRETE TO GET
THE DOOR OPENING TO FIT THE NEW DOOR AND FRAME.
02-14 SEAL DOOR OPENING TO PREVENT DUST FROM LEAVING
CONSTRUCTION AREA.
02-20 REMOVE EXISTING FRAME AND REPLACE. SEE DOOR SCHEDULE.
02-21 REMOVE EXISTING DOOR AND REPLACE. SEE DOOR SCHEDULE.
02-22 REMOVE EXISTING HARDWARE AND REPLACE TO MATCH EXISTING.
SEE DOOR SCHEDULE.
02-23 REMOVE EXISTING MOTION SENSOR AND REPLACE. SEE DOOR
SCHEDULE.
02-24 REMOVE EXISTING OPERATOR AND REPLACE. SEE DOOR SCHEDULE.
02-27 REMOVE EXISTING DOOR, FRAME AND WALL.
GENERAL NOTES:
KEYNOTES:
1/4" = 1'-0"
BUILDING 1 - DOOR BCW02 - ENLARGED PLAN - DEMO
1/4" = 1'-0"
BUILDING 1 - DOOR BS04 - ENLARGED PLAN - DEMO
1/4" = 1'-0"
BUILDING 1 - DOOR BW101 - ENLARGED PLAN - DEMO
1/4" = 1'-0"
BUILDING 1 - DOOR BCS03B - ENLARGED PLAN - DEMO
1/4" = 1'-0"
BUILDING 1 - DOOR BW107 - ENLARGED PLAN - DEMO
1/4" = 1'-0"
BUILDING 1 - DOOR BW110C - ENLARGED PLAN - DEMO
1/4" = 1'-0"
BUILDING 1 - DOOR BW114 - ENLARGED PLAN - DEMO
1/4" = 1'-0"
BUILDING 1 - DOOR BW115 - ENLARGED PLAN - DEMO
1/4" = 1'-0"
BUILDING 1 - DOOR BC07 - ENLARGED PLAN - DEMO
1/4" = 1'-0"
BUILDING 1 - DOOR 1E06 - ENLARGED PLAN - DEMO
1/4" = 1'-0"
BUILDING 1 - DOORS 1CN01 AND 1CN01A - ENLARGED PLAN - DEMO
1/4" = 1'-0"
BUILDING 1 - DOOR 1CN03 - ENLARGED PLAN - DEMO
1/4" = 1'-0"
BUILDING 1 - DOOR 1W36 - ENLARGED PLAN - DEMO
1/4" = 1'-0"
BUILDING 1 - DOOR 1C07 - ENLARGED PLAN - DEMO
1/4" = 1'-0"
BUILDING 1 - DOOR 1CW07 - ENLARGED PLAN - DEMO
1/4" = 1'-0"
BUILDING 1 - DOORS 1W50 AND 1CW07A - ENLARGED PLAN - DEMO
1/4" = 1'-0"
BUILDING 50 - DOOR 50C101 - ENLARGED PLAN - DEMO
1/4" = 1'-0"
BUILDING 1 - DOOR 1CN03A -
ENLARGED PLAN - DEMO
1. SHEET SIZE FOR PROPER SCALE IS 42X30. CONTRACTOR SHALL NOT
SCALE DRAWINGS BUT SHALL REQUEST THE DESIRED DIMENSIONS FROM
THE ARCHITECT.
2. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VISIT THE
PROJECT AND VERIFY EXISTING CONDITIONS/DIMENSIONS AND
PROPOSED CONDITIONS. COORDINATE DEMOLITION BETWEEN ALL
TRADES. NOTIFY A/E IMMEDIATELY OF ANY CONFLICTS OR
DISCREPANCIES.
3. SEE ENLARGED AREA PLANS FOR KEYNOTES.
4. EXISTING AREAS NOT IN CONTRACT SHOWN SHADED FOR CLARITY.
02-11 2 C
S
02-11
02-14
02-14
02-11
2W41 02-25
02-25
02-11
2W44
02-14
02-11
02-2502-25
02-11
02-11
4CE0502-14
02-11
02-24
02-24
4CS04
02-14
02-1102-11
02-24
02-21
02-21
02-24
4CS05
C
S
02-11
02-14
02-11
02-11
02-1402-11 02-24
02-24
02-2402-24
4CS05A
02-14
02-11
02-11
02-24
02-24
4S05 02-21
02-2402-11
02-11
4CS07A
02-14
02-11
02-11
TEMPORARY PARTITION
DEMOLITION LEGEND:
PLAN NORTH
TRUE NORTH
NORTH ARROW
1-HOUR FIRE BARRIER
WALL RATING LEGEND:
2-HOUR FIRE BARRIER
SMOKE BARRIER
2-HOUR FIRE SMOKE
BARRIER
FIRE RATING
SMOKE AND FIRE RATING
1-HOUR FIRE SMOKE
BARRIER
SMOKE PARTITION
SMOKE RESISTIVE
CORRIDOR WALL
4CS03
02-14
02-11
02-1102-21
02-24
02-24
02-21
C
02-14
02-11 02-24
02-11
4CW07
02-11
02-11
02-14
02-24
02-24
02-14
02-11
02-14
02-11
02-14
02-11
02-11
4W54
4W52
C
W
02-21
02-22
02-21
02-20
02-2102-21
02-20
02-11
02-11
4W39
02-11 02-14
02-11
02-24
02-24
C
S
02-11
02-14
02-11
02-2102-21
E
02-14
02-11
02-24
02-11
6CW03
02-14
02-1102-11
02-24
S
T
02-14
02-11
02-11
02-26
9ST03
02-14
02-11
02-11
02-26
C
3 02-11
02-14
02-11
SP103
02-1102-11
02-14
02-14
02-1102-11
02-21
02-24
A
02-14
02-11
02-21
02-11
-7
02-11
02-20
02-21
FOURFRONT DESIGN, INC.
517 7TH STREET
RAPID CITY, SOUTH DAKOTA 57701
PH: (605) 342-9470
FAX: (605) 342-2377
WWW.FOURFRONTDESIGN.COM
FOUR FRONT
D E S I G N I N C.
Project Number
Building Number
Drawing Number
Dwg.
DrawnCheckedDate
Location
Project TitleDrawing Title
COR / Project Engineer
CONSULTANTS:
DateRevisions:
VA FORM 08-6231
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 of
Office of Construction and Facilities Management
Department of Veterans Affairs
Phase
STAMP: ARCHITECT/ENGINEER OF RECORD:
4F PROJECT NO: 19.2481.A26 40
/2 /2
:2
:0
P M
8/28/2024
DEMOLITION PLANS - ENLARGED
AD1.12
UPGRADE DOORS/DOOR
HARDWARE AT IOWA CITY VA
HEALTH CARE SYSTEM
JEKP
IOWA CITY, IOWAMATTHEW RUPPENKAMP
CONSTRUCTION
DOCUMENTS
636A8-23-102
CONSTRUCTION DOCUMENTS
02-11 PROVIDE AND INSTALL TEMPORARY VESTIBULE TO SEPERATE AREAS
OF CONSTRUCTION ACTIVITY FROM ADJACENT AREAS THAT WILL
REMAIN OCCUPIED AND OPERATIONAL.
02-14 SEAL DOOR OPENING TO PREVENT DUST FROM LEAVING
CONSTRUCTION AREA.
02-20 REMOVE EXISTING FRAME AND REPLACE. SEE DOOR SCHEDULE.
02-21 REMOVE EXISTING DOOR AND REPLACE. SEE DOOR SCHEDULE.
02-22 REMOVE EXISTING HARDWARE AND REPLACE TO MATCH EXISTING.
SEE DOOR SCHEDULE.
02-24 REMOVE EXISTING OPERATOR AND REPLACE. SEE DOOR SCHEDULE.
02-25 REMOVE EXISTING HINGES AND REPLACE. REALIGN DOORS AND
ADJUST AS REQUIRED. SEE DOOR SCHEDULE.
02-26 REMOVE EXISTING GLASS AND REPLACE. SEE DOOR SCHEDULE.
GENERAL NOTES:
KEYNOTES:
1/4" = 1'-0"
BUILDING 1 - DOOR 2CS08 -
ENLARGED PLAN - DEMO
1/4" = 1'-0"
BUILDING 1 - DOOR 2W41 -
ENLARGED PLAN - DEMO
1/4" = 1'-0"
BUILDING 1 - DOOR 2W44 -
ENLARGED PLAN - DEMO
1/4" = 1'-0"
BUILDING 1 - DOOR 4CE05 -
ENLARGED PLAN - DEMO
1/4" = 1'-0"
BUILDING 1 - DOOR 4CS04 ENLARGED
PLAN - DEMO
1/4" = 1'-0"
BUILDING 1 - DOORS 4CS05, 4CS06 -
ENLARGED PLAN - DEMO
1/4" = 1'-0"
BUILDING 1 - DOOR 4CS05A -
ENLARGED PLAN - DEMO
1/4" = 1'-0"
BUILDING 1 - DOOR 4S05 - ENLARGED
PLAN - DEMO
1/4" = 1'-0"
BUILDING 1 - DOOR 4CS07A -
ENLARGED PLAN - DEMO
1/4" = 1'-0"
BUILDING 1 - DOORS 4CS03 -
ENLARGED PLAN - DEMO
1/4" = 1'-0"
BUILDING 1 - DOOR 4C10 - ENLARGED
PLAN - DEMO
1/4" = 1'-0"
BUILDING 1 - DOOR 4CW07 -
ENLARGED PLAN - DEMO
1/4" = 1'-0"
BUILDING 1 - DOORS 4W52, 4W54,
4CW10 - ENLARGED PLAN - DEMO
1/4" = 1'-0"
BUILDING 1 - DOOR 4W39 -
ENLARGED PLAN - DEMO
1/4" = 1'-0"
BUILDING 1 - DOOR 5CS02 -
ENLARGED PLAN - DEMO
1/4" = 1'-0"
BUILDING 1 - DOOR 5E03 - ENLARGED
PLAN - DEMO
1/4" = 1'-0"
BUILDING 1 - DOOR 6CW03 -
ENLARGED PLAN - DEMO
1/4" = 1'-0"
BUILDING 1 - DOOR 9ST02 -
ENLARGED PLAN - DEMO
1/4" = 1'-0"
BUILDING 1 - DOOR 9ST03 -
ENLARGED PLAN - DEMO
1/4" = 1'-0"
BUILDING 2 - DOOR 1C03 - ENLARGED
PLAN - DEMO
1/4" = 1'-0"
BUILDING 2 - DOOR 103 - ENLARGED
PLAN - DEMO
1/4" = 1'-0"
BUILDING 2 - DOOR 113 - ENLARGED
PLAN - DEMO
1/4" = 1'-0"
BUILDING 2 - DOOR 113A - ENLARGED
PLAN - DEMO
1/4" = 1'-0"
BUILDING 7 - DOOR 03-7 - ENLARGED
PLAN - DEMO
BE24
B C
BW110C
B W
BCS03B
BW114 BW115
BS04
B W
B C
W
B W
A
B E
B E
A1.11
A1.11
A1.11
A1.11
A1.11
A1.11
A1.11
A1.11
A1.11
A1.11
A1.11
A1.11
A1.11
1. SHEET SIZE FOR PROPER SCALE IS 42X30. CONTRACTOR SHALL NOT
SCALE DRAWINGS BUT SHALL REQUEST THE DESIRED DIMENSIONS FROM
THE ARCHITECT.
2. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VISIT THE
PROJECT AND VERIFY EXISTING CONDITIONS/DIMENSIONS AND
PROPOSED CONDITIONS. COORDINATE DEMOLITION BETWEEN ALL
TRADES. NOTIFY A/E IMMEDIATELY OF ANY CONFLICTS OR
DISCREPANCIES.
3. SEE ENLARGED AREA PLANS FOR KEYNOTES.
4. EXISTING AREAS NOT IN CONTRACT SHOWN SHADED FOR CLARITY.
POINT OF EGRESS
SHEET LEGEND:
NORTH ARROW
PLAN NORTH
TRUE NORTH
1-HOUR FIRE BARRIER
WALL RATING LEGEND:
2-HOUR FIRE BARRIER
SMOKE BARRIER
2-HOUR FIRE SMOKE
BARRIER
FIRE RATING
SMOKE AND FIRE RATING
1-HOUR FIRE SMOKE
BARRIER
SMOKE PARTITION
SMOKE RESISTIVE
CORRIDOR WALL
FOURFRONT DESIGN, INC.
517 7TH STREET
RAPID CITY, SOUTH DAKOTA 57701
PH: (605) 342-9470
FAX: (605) 342-2377
WWW.FOURFRONTDESIGN.COM
FOUR FRONT
D E S I G N I N C.
Project Number
Building Number
Drawing Number
Dwg.
DrawnCheckedDate
Location
Project TitleDrawing Title
COR / Project Engineer
CONSULTANTS:
DateRevisions:
VA FORM 08-6231
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 of
Office of Construction and Facilities Management
Department of Veterans Affairs
Phase
STAMP: ARCHITECT/ENGINEER OF RECORD:
4F PROJECT NO: 19.2481.A26 40
/2 /2
:2
:0
P M
8/28/2024
BUILDING 1 - BASEMENT PLAN
A1.01
UPGRADE DOORS/DOOR
HARDWARE AT IOWA CITY VA
HEALTH CARE SYSTEM
KZKP
IOWA CITY, IOWAMATTHEW RUPPENKAMP
CONSTRUCTION
DOCUMENTS
636A8-23-102
CONSTRUCTION DOCUMENTS
1/16" = 1'-0"
BUILDING 1, BASEMENT
GENERAL NOTES:
SHEET SPECIFIC NOTES:
1. SEE THE DOOR HARDWARE SCHEDULE AND SPECIFICATIONS FOR
NEW DOOR HARDWARE.
UPDN
UP
DN
UP
R
EF.
1. SHEET SIZE FOR PROPER SCALE IS 42X30. CONTRACTOR SHALL NOT
SCALE DRAWINGS BUT SHALL REQUEST THE DESIRED DIMENSIONS FROM
THE ARCHITECT.
2. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VISIT THE
PROJECT AND VERIFY EXISTING CONDITIONS/DIMENSIONS AND
PROPOSED CONDITIONS. COORDINATE DEMOLITION BETWEEN ALL
TRADES. NOTIFY A/E IMMEDIATELY OF ANY CONFLICTS OR
DISCREPANCIES.
3. SEE ENLARGED AREA PLANS FOR KEYNOTES.
4. EXISTING AREAS NOT IN CONTRACT SHOWN SHADED FOR CLARITY.
1CN01A
1CN01
C
N
1W501CW07A
1CW07
1C07
1E06
W
50C101
A1.11
A1.11
A1.11
A1.11
A1.11
A1.11
A1.11
A1.11
1CN03A
A1.11
1-HOUR FIRE BARRIER
WALL RATING LEGEND:
2-HOUR FIRE BARRIER
SMOKE BARRIER
2-HOUR FIRE SMOKE
BARRIER
FIRE RATING
SMOKE AND FIRE RATING
1-HOUR FIRE SMOKE
BARRIER
SMOKE PARTITION
SMOKE RESISTIVE
CORRIDOR WALL
POINT OF EGRESS
SHEET LEGEND:
NORTH ARROW
PLAN NORTH
TRUE NORTH
FOURFRONT DESIGN, INC.
517 7TH STREET
RAPID CITY, SOUTH DAKOTA 57701
PH: (605) 342-9470
FAX: (605) 342-2377
WWW.FOURFRONTDESIGN.COM
FOUR FRONT
D E S I G N I N C.
Project Number
Building Number
Drawing Number
Dwg.
DrawnCheckedDate
Location
Project TitleDrawing Title
COR / Project Engineer
CONSULTANTS:
DateRevisions:
VA FORM 08-6231
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 of
Office of Construction and Facilities Management
Department of Veterans Affairs
Phase
STAMP: ARCHITECT/ENGINEER OF RECORD:
4F PROJECT NO: 19.2481.A26 40
/2 /2
:2
:0
P M
8/28/2024
BUILDINGS 1 AND 50, FLOOR 1 PLAN
A1.02
UPGRADE DOORS/DOOR
HARDWARE AT IOWA CITY VA
HEALTH CARE SYSTEM
KZKP
IOWA CITY, IOWAMATTHEW RUPPENKAMP
CONSTRUCTION
DOCUMENTS
636A8-23-102
CONSTRUCTION DOCUMENTS
GENERAL NOTES:
SHEET SPECIFIC NOTES:
1. SEE THE DOOR HARDWARE SCHEDULE AND SPECIFICATIONS FOR
NEW DOOR HARDWARE.
1/16" = 1'-0"
BUILDING 1, FLOOR 1
UP
DN
UP
2W44
2W41
C
S
A1.12
A1.12
A1.12
1. SHEET SIZE FOR PROPER SCALE IS 42X30. CONTRACTOR SHALL NOT
SCALE DRAWINGS BUT SHALL REQUEST THE DESIRED DIMENSIONS FROM
THE ARCHITECT.
2. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VISIT THE
PROJECT AND VERIFY EXISTING CONDITIONS/DIMENSIONS AND
PROPOSED CONDITIONS. COORDINATE DEMOLITION BETWEEN ALL
TRADES. NOTIFY A/E IMMEDIATELY OF ANY CONFLICTS OR
DISCREPANCIES.
3. SEE ENLARGED AREA PLANS FOR KEYNOTES.
4. EXISTING AREAS NOT IN CONTRACT SHOWN SHADED FOR CLARITY.
POINT OF EGRESS
SHEET LEGEND:
NORTH ARROW
PLAN NORTH
TRUE NORTH
1-HOUR FIRE BARRIER
WALL RATING LEGEND:
2-HOUR FIRE BARRIER
SMOKE BARRIER
2-HOUR FIRE SMOKE
BARRIER
FIRE RATING
SMOKE AND FIRE RATING
1-HOUR FIRE SMOKE
BARRIER
SMOKE PARTITION
SMOKE RESISTIVE
CORRIDOR WALL
FOURFRONT DESIGN, INC.
517 7TH STREET
RAPID CITY, SOUTH DAKOTA 57701
PH: (605) 342-9470
FAX: (605) 342-2377
WWW.FOURFRONTDESIGN.COM
FOUR FRONT
D E S I G N I N C.
Project Number
Building Number
Drawing Number
Dwg.
DrawnCheckedDate
Location
Project TitleDrawing Title
COR / Project Engineer
CONSULTANTS:
DateRevisions:
VA FORM 08-6231
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 of
Office of Construction and Facilities Management
Department of Veterans Affairs
Phase
STAMP: ARCHITECT/ENGINEER OF RECORD:
4F PROJECT NO: 19.2481.A26 40
/2 /2
:2
:0
P M
8/28/2024
BUILDINGS 1 AND 50, FLOOR 2 PLAN
A1.03
UPGRADE DOORS/DOOR
HARDWARE AT IOWA CITY VA
HEALTH CARE SYSTEM
KZKP
IOWA CITY, IOWAMATTHEW RUPPENKAMP
CONSTRUCTION
DOCUMENTS
636A8-23-102
CONSTRUCTION DOCUMENTS
1/16" = 1'-0"
BUILDINGS 1 AND 50, FLOOR 2
GENERAL NOTES:
SHEET SPECIFIC NOTES:
1. SEE THE DOOR HARDWARE SCHEDULE AND SPECIFICATIONS FOR
NEW DOOR HARDWARE.
| Sheets |
| AD1.09 - DEMOLITION PLAN - BUILDING 2, FLOOR 1 PLAN |
| AD1.10 - DEMOLITION PLAN - BUILDING 7 FLOOR PLANS |
| AD1.11 - DEMOLITION PLANS - ENLARGED |
| AD1.12 - DEMOLITION PLANS - ENLARGED |
| A1.01 - BUILDING 1 - BASEMENT PLAN |
File details come from the government source that posted it. Updated .