Drawings_Part2.pdf
PDF 7 MB Posted
- Attached to
- Upgrade Doors and Hardware - Iowa City VAMC
- Solicitation number
- 36C26325B0015_1
About this file
This document is a Demolition Plan drawing for Buildings 1 and 50, Floor 1 at the Iowa City VA Health Care System, prepared by Fourfront Design, Inc. The architectural drawing details specific door demolition and upgrade requirements across multiple rooms and areas. Key specifications include removing existing doors, frames, and hardware for several designated doors (1CN03, 1E06, 1CN01), preparing certain doors for operators and push pads, and coordinating demolition work between trades. The plan includes a comprehensive floor layout with detailed notes instructing contractors to verify existing conditions, dimensions, and coordinate work, with a scale of 1/16" = 1'-0". The project is part of a door hardware upgrade construction document set, with the drawing dated 8/28/2024 and located in Iowa City, Iowa.
View the file
Other files
Show all 31
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DN
UPDN
UP
DN
UP
R
EF.
1CN01A
1CN01
C
N
1W501CW07A
1CW07
1C07
1E06
W
50C101
AD1.11
AD1.11
AD1.11
AD1.11
AD1.11
AD1.11
AD1.11
AD1.11
DOOR 1CW07
SEE DOOR SCHEDULE
DOOR 1CW07A
SEE DOOR SCHEDULE.
DOOR 1W50
SEE DOOR SCHEDULE
DOOR 1CN01
SEE DOOR SCHEDULE.
DOOR 1CN01A
SEE DOOR SCHEDULE.
DOOR 1C07
PREP DOOR FOR OPERATOR AND
PUSH PAD, SEE ELECTRICAL.
DOOR 1E06
REMOVE EXISTING DOOR,
FRAME AND HARDWARE.
SEE DOOR SCHEDULE.
DOOR 1W36
SEE DOOR SCHEDULE.
DOOR 50C101
SEE DOOR SCHEDULE.
DOOR 1CN03
REMOVE EXISTING DOOR,
FRAME AND HARDWARE.
SEE DOOR SCHEDULE.
1CN03A
AD1.11
DOOR 1CN03A
REMOVE FRAME, DOOR AND HARDWARE
1. SHEET SIZE FOR PROPER SCALE IS 42X30. CONTRACTOR SHALL NOT
SCALE DRAWINGS BUT SHALL REQUEST THE DESIRED DIMENSIONS FROM
THE ARCHITECT.
2. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VISIT THE
PROJECT AND VERIFY EXISTING CONDITIONS/DIMENSIONS AND
PROPOSED CONDITIONS. COORDINATE DEMOLITION BETWEEN ALL
TRADES. NOTIFY A/E IMMEDIATELY OF ANY CONFLICTS OR
DISCREPANCIES.
3. SEE ENLARGED AREA PLANS FOR KEYNOTES.
4. EXISTING AREAS NOT IN CONTRACT SHOWN SHADED FOR CLARITY.
POINT OF EGRESS
SHEET LEGEND:
NORTH ARROW
PLAN NORTH
TRUE NORTH
1-HOUR FIRE BARRIER
WALL RATING LEGEND:
2-HOUR FIRE BARRIER
SMOKE BARRIER
2-HOUR FIRE SMOKE
BARRIER
FIRE RATING
SMOKE AND FIRE RATING
1-HOUR FIRE SMOKE
BARRIER
SMOKE PARTITION
SMOKE RESISTIVE
CORRIDOR WALL
FOURFRONT DESIGN, INC.
517 7TH STREET
RAPID CITY, SOUTH DAKOTA 57701
PH: (605) 342-9470
FAX: (605) 342-2377
WWW.FOURFRONTDESIGN.COM
FOUR FRONT
D E S I G N I N C.
Project Number
Building Number
Drawing Number
Dwg.
DrawnCheckedDate
Location
Project TitleDrawing Title
COR / Project Engineer
CONSULTANTS:
DateRevisions:
VA FORM 08-6231
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 of
Office of Construction and Facilities Management
Department of Veterans Affairs
Phase
STAMP: ARCHITECT/ENGINEER OF RECORD:
4F PROJECT NO: 19.2481.A26 40
/2 /2
:2
:2
P M
8/28/2024
DEMOLITION PLAN - BUILDINGS 1
AND 50, FLOOR 1 PLAN
AD1.02
UPGRADE DOORS/DOOR
HARDWARE AT IOWA CITY VA
HEALTH CARE SYSTEM
JEKP
IOWA CITY, IOWAMATTHEW RUPPENKAMP
CONSTRUCTION
DOCUMENTS
636A8-23-102
CONSTRUCTION DOCUMENTS1/16" = 1'-0"
BUILDING 1, FLOOR 1 DEMO PLAN
GENERAL NOTES:
| Sheets |
| AD1.02 - DEMOLITION PLAN - BUILDINGS 1 AND 50, FLOOR 1 PLAN |
| AD1.03 - DEMOLITION PLAN - BUILDINGS 1 AND 50, FLOOR 2 PLAN |
| AD1.05 - DEMOLITION PLAN - BUILDING 1, FLOOR 4 PLAN |
| AD1.06 - DEMOLITION PLAN - BUILDING 1, FLOOR 5 PLAN |
| AD1.07 - DEMOLITION PLAN - BUILDING 1, FLOOR 6 PLAN |
File details come from the government source that posted it. Updated .