Drawings_Part5.pdf
PDF 8 MB Posted
- Attached to
- Upgrade Doors and Hardware - Iowa City VAMC
- Solicitation number
- 36C26325B0015_1
About this file
These are architectural demolition plan drawings for the Iowa City VA Health Care System, specifically for Building 1, covering Floors 5, 6, and 9. The documents are part of a project to upgrade doors and door hardware, prepared by Fourfront Design, Inc. for the Department of Veterans Affairs Office of Construction and Facilities Management. The drawings provide detailed floor plans showing specific demolition requirements, including replacing door frames, hardware, and door operators, and removing fire-rated glass in certain locations. Each floor plan includes general notes emphasizing the contractor's responsibility to verify existing conditions, coordinate demolition between trades, and notify the architect/engineer of any conflicts or discrepancies. The plans use a 1/16" = 1'-0" scale and include legends for sheet orientation, wall ratings, and fire barriers.
View the file
Other files
Show all 31
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1. SHEET SIZE FOR PROPER SCALE IS 42X30. CONTRACTOR SHALL NOT
SCALE DRAWINGS BUT SHALL REQUEST THE DESIRED DIMENSIONS FROM
THE ARCHITECT.
2. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VISIT THE
PROJECT AND VERIFY EXISTING CONDITIONS/DIMENSIONS AND
PROPOSED CONDITIONS. COORDINATE DEMOLITION BETWEEN ALL
TRADES. NOTIFY A/E IMMEDIATELY OF ANY CONFLICTS OR
DISCREPANCIES.
3. SEE ENLARGED AREA PLANS FOR KEYNOTES.
4. EXISTING AREAS NOT IN CONTRACT SHOWN SHADED FOR CLARITY.
C
S
E
AD1.12
AD1.12
DOOR 5CS02
REPLACE DOOR FRAME AND HARDWARE. SEE DOOR SCHEDULE.
DOOR 5E03
REMOVE AND REPLACE DOOR OPERATOR. SEE DOOR SCHEDULE
POINT OF EGRESS
SHEET LEGEND:
NORTH ARROW
PLAN NORTH
TRUE NORTH
1-HOUR FIRE BARRIER
WALL RATING LEGEND:
2-HOUR FIRE BARRIER
SMOKE BARRIER
2-HOUR FIRE SMOKE
BARRIER
FIRE RATING
SMOKE AND FIRE RATING
1-HOUR FIRE SMOKE
BARRIER
SMOKE PARTITION
SMOKE RESISTIVE
CORRIDOR WALL
FOURFRONT DESIGN, INC.
517 7TH STREET
RAPID CITY, SOUTH DAKOTA 57701
PH: (605) 342-9470
FAX: (605) 342-2377
WWW.FOURFRONTDESIGN.COM
FOUR FRONT
D E S I G N I N C.
Project Number
Building Number
Drawing Number
Dwg.
DrawnCheckedDate
Location
Project TitleDrawing Title
COR / Project Engineer
CONSULTANTS:
DateRevisions:
VA FORM 08-6231
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 of
Office of Construction and Facilities Management
Department of Veterans Affairs
Phase
STAMP: ARCHITECT/ENGINEER OF RECORD:
4F PROJECT NO: 19.2481.A26 40
/2 /2
:2
:4
P M
8/28/2024
DEMOLITION PLAN - BUILDING 1,
FLOOR 5 PLAN
AD1.06
UPGRADE DOORS/DOOR
HARDWARE AT IOWA CITY VA
HEALTH CARE SYSTEM
JEKP
IOWA CITY, IOWAMATTHEW RUPPENKAMP
CONSTRUCTION
DOCUMENTS
636A8-23-102
CONSTRUCTION DOCUMENTS
GENERAL NOTES:
1/16" = 1'-0"
BUILDING 1, FLOOR 5 DEMO PLAN
DN
1. SHEET SIZE FOR PROPER SCALE IS 42X30. CONTRACTOR SHALL NOT
SCALE DRAWINGS BUT SHALL REQUEST THE DESIRED DIMENSIONS FROM
THE ARCHITECT.
2. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VISIT THE
PROJECT AND VERIFY EXISTING CONDITIONS/DIMENSIONS AND
PROPOSED CONDITIONS. COORDINATE DEMOLITION BETWEEN ALL
TRADES. NOTIFY A/E IMMEDIATELY OF ANY CONFLICTS OR
DISCREPANCIES.
3. SEE ENLARGED AREA PLANS FOR KEYNOTES.
4. EXISTING AREAS NOT IN CONTRACT SHOWN SHADED FOR CLARITY.
6CW03
AD1.12
DOOR 6CW03
REMOVE AND REPLACE DOOR OPERATOR.
SEE DOOR SCHEDULE.
POINT OF EGRESS
SHEET LEGEND:
NORTH ARROW
PLAN NORTH
TRUE NORTH
1-HOUR FIRE BARRIER
WALL RATING LEGEND:
2-HOUR FIRE BARRIER
SMOKE BARRIER
2-HOUR FIRE SMOKE
BARRIER
FIRE RATING
SMOKE AND FIRE RATING
1-HOUR FIRE SMOKE
BARRIER
SMOKE PARTITION
SMOKE RESISTIVE
CORRIDOR WALL
FOURFRONT DESIGN, INC.
517 7TH STREET
RAPID CITY, SOUTH DAKOTA 57701
PH: (605) 342-9470
FAX: (605) 342-2377
WWW.FOURFRONTDESIGN.COM
FOUR FRONT
D E S I G N I N C.
Project Number
Building Number
Drawing Number
Dwg.
DrawnCheckedDate
Location
Project TitleDrawing Title
COR / Project Engineer
CONSULTANTS:
DateRevisions:
VA FORM 08-6231
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 of
Office of Construction and Facilities Management
Department of Veterans Affairs
Phase
STAMP: ARCHITECT/ENGINEER OF RECORD:
4F PROJECT NO: 19.2481.A26 40
/2 /2
:2
:4
P M
8/28/2024
DEMOLITION PLAN - BUILDING 1,
FLOOR 6 PLAN
AD1.07
UPGRADE DOORS/DOOR
HARDWARE AT IOWA CITY VA
HEALTH CARE SYSTEM
KZKP
IOWA CITY, IOWAMATTHEW RUPPENKAMP
CONSTRUCTION
DOCUMENTS
636A8-23-102
CONSTRUCTION DOCUMENTS
GENERAL NOTES:
1/16" = 1'-0"
BUILDING 1, FLOOR 6 DEMO PLAN
S
T
9ST03
AD1.12
AD1.12
DOOR 9ST03
REMOVE FIRE RATED GLASS. SEE DOOR SCHEDULE.
DOOR 9ST02
REMOVE FIRE RATED GLASS. SEE DOOR SCHEDULE.
1. SHEET SIZE FOR PROPER SCALE IS 42X30. CONTRACTOR SHALL NOT
SCALE DRAWINGS BUT SHALL REQUEST THE DESIRED DIMENSIONS FROM
THE ARCHITECT.
2. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VISIT THE
PROJECT AND VERIFY EXISTING CONDITIONS/DIMENSIONS AND
PROPOSED CONDITIONS. COORDINATE DEMOLITION BETWEEN ALL
TRADES. NOTIFY A/E IMMEDIATELY OF ANY CONFLICTS OR
DISCREPANCIES.
3. SEE ENLARGED AREA PLANS FOR KEYNOTES.
4. EXISTING AREAS NOT IN CONTRACT SHOWN SHADED FOR CLARITY.
POINT OF EGRESS
SHEET LEGEND:
NORTH ARROW
PLAN NORTH
TRUE NORTH
1-HOUR FIRE BARRIER
WALL RATING LEGEND:
2-HOUR FIRE BARRIER
SMOKE BARRIER
2-HOUR FIRE SMOKE
BARRIER
FIRE RATING
SMOKE AND FIRE RATING
1-HOUR FIRE SMOKE
BARRIER
SMOKE PARTITION
SMOKE RESISTIVE
CORRIDOR WALL
FOURFRONT DESIGN, INC.
517 7TH STREET
RAPID CITY, SOUTH DAKOTA 57701
PH: (605) 342-9470
FAX: (605) 342-2377
WWW.FOURFRONTDESIGN.COM
FOUR FRONT
D E S I G N I N C.
Project Number
Building Number
Drawing Number
Dwg.
DrawnCheckedDate
Location
Project TitleDrawing Title
COR / Project Engineer
CONSULTANTS:
DateRevisions:
VA FORM 08-6231
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 of
Office of Construction and Facilities Management
Department of Veterans Affairs
Phase
STAMP: ARCHITECT/ENGINEER OF RECORD:
4F PROJECT NO: 19.2481.A26 40
/2 /2
:2
:5
P M
8/28/2024
DEMOLITION PLAN - BUILDING 1,
FLOOR 9
AD1.08
UPGRADE DOORS/DOOR
HARDWARE AT IOWA CITY VA
HEALTH CARE SYSTEM
KZKP
IOWA CITY, IOWAMATTHEW RUPPENKAMP
CONSTRUCTION
DOCUMENTS
636A8-23-102
CONSTRUCTION DOCUMENTS
1/16" = 1'-0"
BUILDING 1, FLOOR 9 DEMO PLAN
GENERAL NOTES:
| Sheets |
| AD1.06 - DEMOLITION PLAN - BUILDING 1, FLOOR 5 PLAN |
| AD1.07 - DEMOLITION PLAN - BUILDING 1, FLOOR 6 PLAN |
| AD1.08 - DEMOLITION PLAN - BUILDING 1, FLOOR 9 |
| AD1.09 - DEMOLITION PLAN - BUILDING 2, FLOOR 1 PLAN |
| AD1.10 - DEMOLITION PLAN - BUILDING 7 FLOOR PLANS |
File details come from the government source that posted it. Updated .