Updated Door Schedule Dwg No. A6.00.pdf

PDF 431 KB Posted

Attached to
Upgrade Doors and Hardware - Iowa City VAMC
Solicitation number
36C26325B0015_1
Issued by

About this file

This document is a door schedule for an upgrade project at the Iowa City VA Health Care System, detailing door replacements and modifications across multiple buildings and levels. The comprehensive schedule covers Buildings 1, 2, 7, and 50, with specific details for each door including fire rating, panel dimensions, materials, finishes, hardware groups, and installation requirements. The project involves replacing, modifying, and upgrading doors with various specifications such as adding operators, access control, Personal Identity Verification (PIV), and maintaining egress paths. Work is to be performed during routine work hours, nights, or weekends, with careful coordination required to minimize disruption. The door upgrades include different types of doors (hollow metal, wood, aluminum, fiberglass) with various finishes and functional requirements, such as fire-rated glass, lead-lined doors, and integration with existing access control systems.

View the file

Other files

File Type Posted
ICRA DOOR SCHEDULE_20240719.xlsx XLSX spreadsheet
636A8-23-102 Upgrade Doors Hardware QA_Revised 9.5.25.docx DOCX document
36C26325B0015 0004.docx DOCX document
Specifications Revised 9.3.25.pdf PDF
636A8-23-102 Upgrade Doors Hardware QA.docx DOCX document
36C26325B0015 0003.docx DOCX document
Site Visit Sign in Sheet.pdf PDF
Wage Determination IA20250068 8.22.25.pdf PDF
JA Best Access Systems - Cormax_Redacted.pdf PDF
36C26325B0015 0002.docx DOCX document
Specifications Revised 8.18.25.pdf PDF
Final SOW_8.18.25.docx DOCX document
JA Honeywell - Lenel Fully_Redacted.pdf PDF
36C26325B0015 0001 (Amendment 0001).pdf PDF
Questions_Answers or Clarifications (Attachment).pdf PDF
IFB Attachment - Site Visit Campus Map.pdf PDF
36C26325B0015_1.docx DOCX document
Drawings_Part1.pdf PDF
Drawings_Part4.pdf PDF
TMS 20939 VA Privacy Training.pdf PDF
Specifications 486 pages.pdf PDF
Safety or Environmental Violations and EMR Information 2 pages.pdf PDF
SOW Final 6 pages.pdf PDF
Drawings_Part3.pdf PDF
Drawings_Part5.pdf PDF
Drawings_Part6.pdf PDF
Wage Determination 8-8-2025 7 pages.pdf PDF
Limitations on Subcontracting Certificate of Compliance 2 pages.pdf PDF
VA Handbook 6500.6 Appendix C.pdf PDF
Drawings_Part2.pdf PDF
Drawings_Part7.pdf PDF
Show all 31

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ALUM ALUMINUM

F FLUSH FULL

FG FULL GLASS

FRP FIBERGLASS REINFORCED POLYMER

FTF FACTORY TRANSPARENT FINISH

HM HOLLOW METAL

ME MATCH EXISTING

NV NARROW VIEW

PTE PAINT TO MATCH EXISTING

SG SPLIT GLASS

STE STAIN TO MATCH EXISTING

PIV PERSONAL IDENTITY VERIFICATION

VV VISION VIEW

WD WOOD

DOOR LEGEND:

FOURFRONT DESIGN, INC.

517 7TH STREET

RAPID CITY, SOUTH DAKOTA 57701

PH: (605) 342-9470

FAX: (605) 342-2377

WWW.FOURFRONTDESIGN.COM

FOUR FRONT

D E S I G N I N C.

Project Number

Building Number

Drawing Number

Dwg.

DrawnCheckedDate

Location

Project TitleDrawing Title

COR / Project Engineer

CONSULTANTS:

DateRevisions:

VA FORM 08-6231

o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9

F

E

D

C

B

A

1 2 3 4 5 6 7 8 9 of

Office of Construction and Facilities Management

Department of Veterans Affairs

Phase

STAMP: ARCHITECT/ENGINEER OF RECORD:

4F PROJECT NO: 19.2481.A26 40

/2 /2

:2

:1

P M

8/28/2024

DOOR SCHEDULES

A6.00

UPGRADE DOORS/DOOR

HARDWARE AT IOWA CITY VA

HEALTH CARE SYSTEM

JEKP

IOWA CITY, IOWAMATTHEW RUPPENKAMP

CONSTRUCTION

DOCUMENTS

636A8-23-102

CONSTRUCTION DOCUMENTS

DOOR SCHEDULE - BUILDING 1

Level

DOOR

NUMBER FIRE RATING

PANEL

WIDTH

PANEL

HEIGHT

PANEL

THICKNESS

PANEL

COUNT PANEL TYPE

PANEL

MATERIAL

PANEL

FINISH

GLAZING

TYPE

FRAME

TYPE

FRAME

MATERIAL FRAME FINISH HEAD JAMB SILL

HARDWARE

GROUP

NEW

OPERATOR

NEW

PIV PHASING* NOT USED COMMENTS

BUILDING 1

BASEMENT BC07 --- 3' - 8" 7' - 0" --- 1 HG ALUM FTF --- AL-002 ALUM FTF 5/A6.01 10/A6.01 11/A6.01 02 NO NO ROUTINE WORK HOURS NEW ALUM DOOR AND FRAME REUSE ACCESS CONTROL AND OPERATOR, ADD INSIDE ACTUATOR / MAINTAIN MOTION SENSORS IN THE

PATH OF EGRESS

BASEMENT BCS03B 90 MIN. 3' - 0" 7' - 0" 1 3/4" 1 NV EXISTING PTE --- EXISTING HM PTE --- --- --- 03 NO NO NIGHT OR WEEKEND AND NOT AT THE

SAME TIME AS BW107, BW101, BCW02

ADD NEW MOTION SENSOR / MAINTAIN MOTION SENSORS IN THE PATH OF EGRESS

BASEMENT BCW02 90 MIN. 7' - 0" 7' - 0" 1 3/4" 2 NV HM PTE --- HM-001 HM PTE 1/A6.01 6/A6.01 04 NO NO START FRIDAY NIGHT AND FINISH BY

SUNDAY NIGHT AND NOT AT THE SAME

TIME AS BCS03B, BW107, BW101

NEW DOOR, FRAME AND HARDWARE

BASEMENT BE00 --- 3' - 0" 6' - 0" 1 3/4" 1 F HM PTE --- HM-001 HM PTE 3/A6.01 8/A6.01 --- 01 NO NO ROUTINE WORK HOURS NEW DOOR, FRAME AND HARDWARE FRAME SET IN BRICK VENEER WITH CONCRETE WALLS

BASEMENT BE01 --- 3' - 0" 7' - 0" 1 3/4" 1 F HM PTE --- 4 - SIDED HM PTE 4/A6.01 9/A6.01 --- 01 NO NO ROUTINE WORK HOURS NEW DOOR, FRAME AND HARDWARE FRAME SET IN BRICK VENEER WITH CONCRETE WALLS

BASEMENT BE24 45 MIN. 6' - 0" 7' - 0" 1 3/4" 2 NV HM PTE --- HM-001 HM PTE 1/A6.01 6/A6.01 --- 05 NO NO ROUTINE WORK HOURS NEW DOOR, FRAME AND HARDWARE RECONNECT ACCESS CONTROL

BASEMENT BS04 --- 4' - 0" 7' - 0" 1 3/4" 1 F WD STE --- HM-001 HM PTE 1/A6.01 6/A6.01 --- 06 NO NO ROUTINE WORK HOURS NEW DOOR, FRAME AND HARDWARE

BASEMENT BW12A --- 3' - 0" 7' - 0" 1 3/4" 1 F HM PTE --- HM-001 HM PTE 3/A6.01 8/A6.01 --- 07 NO NO ROUTINE WORK HOURS NEW DOOR, FRAME AND HARDWARE FRAME SET IN BRICK VENEER WITH CONCRETE WALLS

BASEMENT BW101 --- 7' - 0" 7' - 0" 1 3/4" 2 NV EXISTING EXISTING --- EXISTING EXISTING EXISTING --- --- --- 03 NO NO NIGHT OR WEEKEND AND NOT AT THE

SAME TIME AS BCS03B, BW107, BCW02

ADD NEW MOTION SENSOR

BASEMENT BW107 --- 6' - 0" 7' - 0" 1 3/4" 2 NV EXISTING PTE --- EXISTING EXISTING FTF --- --- --- 03 NO NO NIGHT OR WEEKEND AND NOT AT THE

SAME TIME AS BW101, BCW02, BCS03B

ADD NEW MOTION SENSOR / PAINT EXISITING HM DOOR AND FRAME

BASEMENT BW110C 45 MIN. 3' - 0" 7' - 0" 1 3/4" 1 F HM PTE --- HM-001 HM PTE 1/A6.01 6/A6.01 --- 08 NO NO ROUTINE WORK HOURS NEW DOOR, FRAME AND HARDWARE RECONNECTING ACCESS CONTROL, NEW ELECTRIC STRIKE

BASEMENT BW114 45 MIN. 3' - 8" 7' - 0" 1 3/4" 1 NV HM PTE --- HM-001 HM PTE 1/A6.01 6/A6.01 --- 08 NO NO ROUTINE WORK HOURS NEW DOOR, FRAME AND HARDWARE RECONNECTING ACCESS CONTROL, NEW ELECTRIC STRIKE, NARROW LIGHT GLASS

BASEMENT BW115 45 MIN. 3' - 8" 7' - 0" 1 3/4" 1 NV HM PTE --- HM-001 HM PTE 1/A6.01 6/A6.01 --- 08 NO NO ROUTINE WORK HOURS NEW DOOR AND FRAME / TO MATCH WARD / FIRE RATED GLASS / CLASSROOM W/ NARROW LIGHT

LEVEL 1 1C07 --- 3' - 6" 7' - 0" 1 3/4" 1 F EXISTING STE --- EXISTING EXISTING PTE --- --- --- 09 YES NO ROUTINE WORK HOURS ADD OPERATOR AND PUSH BUTTON OPENER AND TIE INTO EXISTING ACCESS CONTROL

LEVEL 1 1CN01 --- 12' - 6" 7' - 0" --- 2 ME ALUM ME --- AL-101 ALUM ME 2/A6.01 7/A6.01 --- SLIDER NO NO NIGHT OR WEEKEND, MAINTAIN EGRESS, FIREWATCH

NEW AUTO SLIDING DOORS / MAINTAIN MOTION SENSORS IN THE PATH OF EGRESS

LEVEL 1 1CN01A --- 12' - 6" 7' - 0" --- 2 ME ALUM ME --- AL-101 ALUM ME 2/A6.01 7/A6.01 --- SLIDER NO NO NIGHT OR WEEKEND, MAINTAIN EGRESS, FIREWATCH

NEW AUTO SLIDING DOORS / MAINTAIN MOTION SENSORS IN THE PATH OF EGRESS

LEVEL 1 1CN03 --- 5' - 8" 7' - 0" 1 3/4" 2 UNEVEN HG WD STE --- HM-001 HM PTE 1/A6.01 6/A6.01 --- 10 YES YES ROUTINE WORK HOURS NEW DOOR AND FRAME AND HARDWARE- 3'-8" PANEL WITH HALF GLASS AND SOLID PANEL FOR 2'-0" FLUSH PANEL WITH ELEC EXIT

DEVICE

LEVEL 1 1CN03A --- 4' - 0" 7' - 0" 1 3/4" 1 VV WD STE --- HM HM PTE 1/A6.01 6/A6.01 --- 28 YES YES ROUTINE WORK HOURS REPLACE DOOR AND FRAME ADD ACCESS CONTROL ADD OPERATOR

LEVEL 1 1CW07 --- 6' - 0" 7' - 0" 1 3/4" 2 FG EXISTING PTE --- EXISTING ALUM ALUM --- --- --- 15 YES NO NIGHT, MAINTAIN EGRESS REMOVE AND REPLACE OPERATOR / MAINTAIN MOTION SENSORS IN THE PATH OF EGRESS

LEVEL 1 1CW07A --- 6' - 4" 7' - 0" 1 3/4" 2 FG EXISTING PTE --- EXISTING ALUM FTF --- --- --- 15 YES NO NIGHT, MAINTAIN EGRESS REMOVE AND REPLACE OPERATOR / MAINTAIN MOTION SENSORS IN THE PATH OF EGRESS

LEVEL 1 1E06 --- 3' - 0" 7' - 0" 1 3/4" 1 F WD STE --- HM-001 HM PTE 1/A6.01 6/A6.01 --- 16 NO NO ROUTINE WORK HOURS NEW DOOR, FRAME AND HARDWARE

LEVEL 1 1W36 SMOKE

BARRIER

3' - 6" 7' - 0" 1 3/4" 1 F EXISTING PTE --- EXISTING HM PTE --- --- --- 09 YES NO ROUTINE WORK HOURS ADD OPERATOR AND PUSH BUTTON OPENER AND TIE INTO EXISTING ACCESS CONTROL / MAINTAIN MOTION SENSORS IN THE PATH OF

EGRESS

LEVEL 1 1W50 --- 6' - 5 1/2" 7' - 0" 1 3/4" 2 FG EXISTING PTE --- EXISTING ALUM ALUM --- --- --- 15 YES NO NIGHT OR WEEKEND, MAINTAIN EGRESS, FIREWATCH

REMOVE AND REPLACE OPERATOR / MAINTAIN MOTION SENSORS IN THE PATH OF EGRESS

LEVEL 2 2CS08 --- 4' - 0" 7' - 0" 1 3/4" 1 FG EXISTING STE --- EXISTING HM PTE --- --- --- N/A YES NO NIGHT OR WEEKEND ADD OPERATOR, MOVE EXISTING SENSOR, ADD HIDDEN PUSH BUTTON AT RECEPTION DESK, COORDINATE LOCATION WITH COR. /

MAINTAIN MOTION SENSORS IN THE PATH OF EGRESS

LEVEL 2 2W41 --- 5' - 8" 9' - 0" 1 3/4" 2 UNEVEN F WD - LEAD

LINED

STE --- HM - LEAD

LINED

HM PTE --- --- --- 21 NO NO NOT AT THE SAME TIME AS 2W44 REPLACE WOOD SLAB DOORS AND HARDWARE

LEVEL 2 2W44 --- 5' - 8" 9' - 0" 1 3/4" 2 UNEVEN F WD - LEAD

LINED

STE --- HM - LEAD

LINED

HM PTE --- --- --- 21 NO NO NOT AT THE SAME TIME AS 2W41 REPLACE WOOD SLAB DOORS AND HARDWARE

LEVEL 4 4C10 --- 4' - 0" 7' - 0" 1 3/4" 1 F EXISTING STE --- EXISTING HM PTE --- --- --- 18 YES NO MAINTAIN EGRESS REMOVE AND REPLACE OPERATOR / MAINTAIN MOTION SENSORS IN THE PATH OF EGRESS

LEVEL 4 4CE05 SMOKE

BARRIER

7' - 0" 7' - 0" 1 3/4" 2 F EXISTING STE --- EXISTING HM PTE 1/A6.01 6/A6.01 --- 24 YES NO MAINTAIN EGRESS REMOVE AND REPLACE OPERATOR ADD SMOKE SEALS

LEVEL 4 4CS03 SMOKE

BARRIER

7' - 0" 7' - 0" 1 3/4" 2 F EXISTING STE --- EXISTING HM PTE 1/A6.01 6/A6.01 --- 25 YES NO NIGHT OR WEEKEND AND NOT AT THE

SAME TIME AS 4CS04

REMOVE AND REPLACE OPERATOR / ADD NEW UL ARMOR PLATES / SHIM DOOR TO MEET NFPA101 REQUIREMENTS / MAINTAIN MOTION

SENSOR IN THE PATH OF EGRESS

LEVEL 4 4CS04 --- 7' - 0" 7' - 0" --- 2 F EXISTING STE --- EXISTING HM PTE --- --- --- 25 YES NO NIGHT OR WEEKEND AND NOT AT THE

SAME TIME AS 4CS03

REMOVE AND REPLACE OPERATOR / MAINTAIN MOTION SENSOR IN THE PATH OF EGRESS

LEVEL 4 4CS05 SMOKE

BARRIER

7' - 0" 7' - 0" --- 2 F EXISTING STE --- EXISTING HM PTE --- --- --- 23 YES NO NIGHT OR WEEKEND AND NOT AT THE

SAME TIME AS 4CS06 OR 4CS05A,

MAINTAIN EGRESS

REMOVE AND REPLACE OPERATOR / MAINTAIN MOTION SENSOR IN THE PATH OF EGRESS

LEVEL 4 4CS05A --- 7' - 0" 7' - 0" --- 2 F EXISTING STE --- EXISTING HM PTE --- --- --- 23 YES NO NIGHT OR WEEKEND AND NOT AT THE

SAME TIME AS 4CS06 OR 4CS05,

MAINTAIN EGRESS

REMOVE AND REPLACE OPERATOR

LEVEL 4 4CS06 --- 7' - 0" 7' - 0" 1 3/4" 2 F EXISTING STE --- EXISTING HM PTE --- --- --- 26 YES NO NIGHT OR WEEKEND AND NOT AT THE

SAME TIME AS 4CS05 OR 4CS05A,

MAINTAIN EGRESS

REMOVE AND REPLACE OPERATOR AND ARMOR PLATES / MAINTAIN MOTIONSENSORS IN THE PATH OF EGRESS

LEVEL 4 4CS07A SMOKE

BARRIER

7' - 0" 7' - 0" 1 3/4" 2 F EXISTING STE --- EXISTING HM PTE --- --- --- 27 NO NO NIGHT OR WEEKEND AND NOT AT THE

SAME TIME AS 4CS05, 4CS05A, 4CS06,

MAINTAIN EGRESS

REMOVE AND REPLACE ARMOR PLATE

LEVEL 4 4CW07 --- 7' - 0" 7' - 0" 1 3/4" 2 NV EXISTING PTE --- EXISTING HM PTE --- --- --- 23 YES NO NIGHT OR WEEKEND AND NOT AT THE

SAME TIME AS 4W39, MAINTAIN EGRESS

REMOVE AND REPLACE OPERATOR

LEVEL 4 4CW10 --- 7' - 6" 7' - 0" 1 3/4" 2 F EXISTING PTE --- EXISTING HM PTE --- --- --- N/A NO NO ANYTIME REMOVE AND REPLACE OPERATOR / MAINTAIN MOTION SENSOR IN THE PATH OF EGRESS

LEVEL 4 4S05 --- 3' - 0" 7' - 0" 1 3/4" 1 VV WD - LEAD

LINED

STE LEAD LINED

TO MATCH

DOOR

HM - LEAD

LINED

HM PTE 1/A6.01 6/A6.01 --- 28 YES NO ROUTINE WORK HOURS REPLACE DOOR AND FRAME ACCESS CONTROL ADD OPERATOR LEAD LINED DOOR / 4'-7", ENSURE LEAD LINER OVERLAPS DRY WALL.

LEVEL 4 4W39 SMOKE

BARRIER

7' - 0" 7' - 0" 1 3/4" 2 F EXISTING PTE --- EXISTING HM PTE --- --- --- 15 YES NO NIGHT OR WEEKEND AND NOT AT THE

SAME TIME AS 4CW07, MAINTAIN

EGRESS

REMOVE AND REPLACE OPERATOR

LEVEL 4 4W52 --- 3' - 0" 7' - 0" 1 3/4" 1 NV WD STE --- HM-001 HM PTE 1/A6.01 6/A6.01 --- 32 NO YES ROUTINE WORK HOURS NEW FRAME, DOOR AND HARDWARE

LEVEL 4 4W54 45 MIN. 4' - 0" 7' - 0" 1 3/4" 1 F HM PTE --- EXISTING HM PTE --- --- --- 31 NO YES ROUTINE WORK HOURS EXISTING FRAME NEW DOOR AND HARDWARE

LEVEL 5 5CS02 --- 5' - 7 5/8" 7' - 0" 1 3/4" 2 UNEVEN NV HM PTE --- HM-002 HM PTE 1/A6.01 6/A6.01 --- 33 NO NO NIGHT OR WEEKEND, MAINTAIN EGRESS REPLACE DOOR FRAME AND HARDWARE RECONNECT ACCESS CONTROL

LEVEL 5 5E03 45 MIN. 3' - 0" 7' - 0" 1 3/4" 1 F EXISTING STE --- EXISTING HM PTE --- --- --- 18 YES NO ANYTIME REMOVE AND REPLACE OPERATOR

LEVEL 6 6CW03 --- 3' - 8" 7' - 0" 1 3/4" 1 SG EXISTING PTE --- EXISTING HM PTE --- --- --- 18 YES NO MAINTAIN EGRESS REMOVE AND REPLACE OPERATOR

LEVEL 9 9ST02 90 MIN. 3' - 8" 7' - 0" 1 3/4" 1 NV EXISTING PTE CLEAR AND

RATED

EXISTING HM PTE 1/A6.01 6/A6.01 --- N/A NO NO MAINTAIN EGRESS REMOVE AND REPLACE FIRE RATED GLASS / 90 MIN.

LEVEL 9 9ST03 90 MIN. 3' - 8" 7' - 0" 1 3/4" 1 NV EXISTING PTE CLEAR AND

RATED

EXISTING HM PTE 3/A6.01 8/A6.01 --- N/A NO NO MAINTAIN EGRESS REMOVE AND REPLACE FIRE RATED GLASS / 90 MIN., ADD NEW SEALS

DOOR SCHEDULE - BUILDINGS 2, 7, AND 50

Level

DOOR

NUMBER FIRE RATING

PANEL

WIDTH

PANEL

HEIGHT

PANEL

THICKNESS

PANEL

COUNT PANEL TYPE

PANEL

MATERIAL

PANEL

FINISH

GLAZING

TYPE

FRAME

TYPE

FRAME

MATERIAL FRAME FINISH HEAD JAMB SILL

HARDWARE

GROUP

NEW

OPERATOR

NEW

PIV PHASING* NOT USED COMMENTS

BUILDING 2

LEVEL 1 1C03 45 MIN. 7' - 4" 7' - 0" 1 3/4" 2 NV EXISTING PTE --- EXISTING HM PTE --- --- --- N/A YES NO NIGHT OR WEEKEND, MAINTAIN EGRESS REMOVE AND REPLACE OPERATOR

LEVEL 1 103 45 MIN. 7' - 0" 7' - 0" 1 3/4" 2 F HM PTE --- HM-001 HM PTE 1/A6.01 6/A6.01 --- YES YES NIGHT OR WEEKEND, MAINTAIN EGRESS NEW DOOR, FRAME AND OPERATOR

LEVEL 1 113 --- 3' - 0" 7' - 0" 1 3/4" 1 NV EXISTING STE --- EXISTING HM PTE --- --- --- 18 YES NO NIGHT OR WEEKEND REMOVE AND REPLACE OPERATOR

LEVEL 1 113A --- 3' - 0" 7' - 0" 1 3/4" 1 FG WD STE --- EXISTING HM PTE --- --- --- 34 NO NO ANYTIME REPLACE EXISTING DOOR WITH NEW SOLID CORE DOOR WITH NO WINDOW

BUILDING 7

LEVEL 1 03-7 --- 3' - 0" 7' - 0" 1 3/4" 1 F HM PTE --- HM-001 HM PTE 4/A6.01 9/A6.01 --- 35 NO NO MAINTAIN EGRESS REPLACE EXISTING DOOR, FRAME AND HARDWARE

BUILDING 50

LEVEL 1 50C101 --- 7' - 6 1/4" 7' - 0" 1 3/4" 1 AL-FG ALUM ALUM --- AL-001 ALUM ALUM 2/A6.01 7/A6.01 --- - YES YES MAINTAIN EGRESS NEW ALUMINUM DOOR W/ OPERATORS ADD PIV AND ACCESS CONTROL

*All Phasing Must Be Coordinated With COR

*All Phasing Must Be Coordinated With COR

Sheets
G0.00 - COVER SHEET
G0.01 - CAMPUS MAP
G1.00 - INFECTION CONTROL RISK ASSESSMENT
AD1.01 - DEMOLITION PLAN - BUILDING 1 - BASEMENT PLAN
AD1.02 - DEMOLITION PLAN - BUILDINGS 1 AND 50, FLOOR 1 PLAN
AD1.03 - DEMOLITION PLAN - BUILDINGS 1 AND 50, FLOOR 2 PLAN
AD1.05 - DEMOLITION PLAN - BUILDING 1, FLOOR 4 PLAN
AD1.06 - DEMOLITION PLAN - BUILDING 1, FLOOR 5 PLAN
AD1.07 - DEMOLITION PLAN - BUILDING 1, FLOOR 6 PLAN
AD1.08 - DEMOLITION PLAN - BUILDING 1, FLOOR 9
AD1.09 - DEMOLITION PLAN - BUILDING 2, FLOOR 1 PLAN
AD1.10 - DEMOLITION PLAN - BUILDING 7 FLOOR PLANS
AD1.11 - DEMOLITION PLANS - ENLARGED
AD1.12 - DEMOLITION PLANS - ENLARGED
A1.01 - BUILDING 1 - BASEMENT PLAN
A1.02 - BUILDINGS 1 AND 50, FLOOR 1 PLAN
A1.03 - BUILDINGS 1 AND 50, FLOOR 2 PLAN
A1.05 - BUILDING 1, FLOOR 4 PLAN
A1.06 - BUILDING 1, FLOOR 5 PLAN
A1.07 - BUILDING 1, FLOOR 6 PLAN
A1.08 - BUILDING 1, FLOOR 9 PLAN
A1.09 - BUILDING 2, FLOOR 1 PLAN
A1.10 - BUILDING 7 FLOOR PLANS
A1.11 - NEW CONSTRUCTION PLANS - ENLARGED
A1.12 - NEW CONSTRUCTION PLANS - ENLARGED
A6.00 - DOOR SCHEDULES
A6.01 - DOOR ELEVATIONS AND DETAILS
Untitled
Untitled

File details come from the government source that posted it. Updated .