Drawings 6 of 12.pdf
PDF 6 MB Posted
- Solicitation number
- RFQ 171 230000000791 2
- Issued by
- Barry County, Michigan
About this file
This file consists of mechanical demolition and construction drawings prepared by Matrix Consulting for the Department of Technology, Management and Budget, State Facilities Administration, Design and Construction Division of the State of Michigan. The drawings depict demolition work across three connected buildings (29A, 29B, and 29C) with both base bid and alternate pricing options. The project involves extensive disconnection, removal, and demolition of existing HVAC systems including relief air ductwork, intake louvers, cooling coils, supply and return air ductwork, pneumatic VAV boxes, and associated controls and accessories. Additional demolition includes piping systems such as steam piping, heating water supply and return piping, condensate piping, expansion tanks, circulation pumps, heat exchanger skids, radiant floor heating systems, radiant ceiling panels, and pneumatic control systems. The drawings are scaled appropriately for construction and include detailed demolition notes with numbered references corresponding to specific areas on each plan, covering basement, first floor, and attic spaces across all three buildings.
The contract work is organized with a base bid for Buildings 29A and portions of 29B, and alternate pricing (Add Alternate #1) for Buildings 29B and 29C. Multiple systems are designated to remain in place, including existing make-up air units, supply fans, exhaust fans, certain louvers, cabinet unit heaters, condensing units, fin tube heating elements, and radiant heating systems designated for reuse. The project involves modification of existing piping and ductwork connections to accommodate new control valves, shutoff valves, and balance valves. Construction is scheduled based on the issue date of September 14, 2023, with drawings prepared by DBP and checked by CAT under consultant job number 20080.00 and contract order number 472/LCFMAINTPROJ with funding code 472/19503.SMD.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
X-8x8
SA DN
X-20x12
SA DN
X-14x10
SA DN
X-20x10
SA DN
X-10x10
SA DN
X-18x10
SA DN
X-14x10
SA DN
X-12x10
RA DN
X-16x10
RA DN
X-10x10 RA DN
X-12x8
SA DN
X-24x12
RA DN
X-10x10
EA DN
X-28x10
SA DN
X-10" EA DN
X-18x16
RA DN
X-12x8
SA DN
X-12x8
EA DN
X-20x16
RA DN
X-12x10
EA DN
X-20x10
RA DN
X-8x8
EA DN
X-20x12
SA DN
X-18x18
RA DN
X-18x12
EA DN
X-18x18
RA DN
X-EXHAUST
LOUVER
X-16x10 RA
X-18x18 RA X-20x18 RA
X-10x10 RA
X-14x22 RA X-36x22 RA
X-22x22 RA
X-32x16
RA
X-20x16 RA X-18x16 RA
X-14x16 RA
X-18x16 RA
X-36x32 RA
X-18x18 RA
X-18x18 RA
X-36x26 RA X-38x10 RA
(BELOW)
X-38x30 RA
X-20x24
OA
X-20x20
OA
X-30x24 OA
X-20x12 SA X-12x8 SA X-20x14
SA
X-16x6 SA
X-6x6
SA
X-14x8
SA
X-22x16 SA X-24x28
SA
X-30x16
SA
X-16x18
SA
X-18x18
SA
X-16x16 SA
X-22x14 SA
X-2x14 SA
X-8x6 SA
X-4x4 SA
X-8x6 SA
X-8x6 SA X-2x12 SA
X-20x12 SA
X-8x6 SA X-16x6 SA
X-8x6 SA
X-14x8 SA
X-16x6 SAX-14x10 SAX-16x6 SA
X-12x16
SA
X-18x12 SA
X-12x8 SA
X-12x8 SA
X-16x10 SA
X-10x6 SA X-16x6 SA
X-16x8 SA
X-24x30 SA
X-34x26
SA
X-18x32
SA
X-34x18
SA
X-8x10 SA
X-24x24 SAX-24x16 SA
X-24x16 SA
X-16x10
SA
X-20x8 SA
X-16x6 SA
X-10x10 EA X-16x10 EA
X-12x10
EA
X-12x8 EA
X-8x12 EA
X-20x10 EA X-20x12 EA X-22"ø EA
X-18x12 EA
X-HC
X-FILTER
X-SF-10
X-RF-10
X-12x12 SA
X-12x24 SA
X-14"ø SA X-14"ø SA
X-12"ø SA X-12"ø SA
X-20x20 SA
X-20x18
SA
X-20x16
SA
X-14x10 SA
X-12x16
SA
X-10x16 SA
X-8x6 SA
X-6x8SA
X-INTAKE LOUVER
X-8x8
SA DN
X-40x20 RA
X-8x6
EA DN
X-20x20 EA
X-MAU
X-16x16 SA
X-SF-13
X-12x20 SA
X-12x8
SA DN
X-12x8
SA DN
X-EF-10
X-EXHAUST
LOUVER
X-RELIEF
LOUVER
X-INTAKE
LOUVER
X-INTAKE
LOUVER X-INTAKE
LOUVER
X-80x76 RA
X-38x32 SA
X-SD 400
20x6 TYP. 4
X-8x8
SA DN
X-8x8
SA DN
X-8x8
SA DN
X-8x8
SA DN
X-8x6
SA DN
X-12x12
SA DN
X-EF-19
X-16x6
SA DN
X- SA DN
TO X-CUH
(280 CFM)
X-6x6
SA DN
X-12x10
SA DN
X-26x12
SA DN
X-16x6
SA DN
X-16x6
SA DN
X-8x6
SA DN
X-16x6
SA DN
X-16x6
SA DN
X-8x6
SA DN
X-8x6
SA DN
X-8x6
SA DN
X-8x6
SA DN
X-8x6
SA DN
X-HUMIDIFIER
X-HC
X-FILTER
X-CC
2 2
4 4
X-4x4 SA DN
DEMOLITION NOTES
DISCONNECT, REMOVE AND DEMO EXISTING
RELIEF AIR DUCTWORK AND ALL ASSOCIATED
ACCESSORIES IN THEIR ENTIRETY. EXISTING
LOUVER TO REMAIN. BLANK OFF UNUSED
LOUVER SECTION WITH GALVANIZED STEEL
AND INSTALL 2" FIBERBOARD INSULATION
BEHIND BLANK OFF.
DISCONNECT, REMOVE, AND DEMO EXISTING
INTAKE LOUVER AND ALL ASSOCIATED
ACCESSORIES IN THEIR ENTIRETY.
DISCONNECT, REMOVE AND DEMO EXISTING
SHED DORMER LOUVER OPENING PER
ARCHITECTURAL DRAWINGS. PATCH ROOF
PENETRATION NOT USED FOR NEW SUPPLY AIR
DUCT AND RETURN AIR DUCT ROUTING PER
ARCHITECTURAL DRAWINGS TO MAINTAIN ALL
WARRANTIES, MATCH EXISTING ROOFING, AND
SEAL WATER TIGHT.
DISCONNECT, REMOVE, AND DEMO EXISTING
INTAKE LOUVER, OUTSIDE AIR DUCTWORK,
HEATING COILS, FILTERS, AND ALL ASSOCIATED
ACCESSORIES. REUSE ROOF PENETRATION
FOR ROUTING OF NEW SUPPLY AND RETURN
AIR DUCTWORK INTO ATTIC.
DISCONNECT, REMOVE, AND DEMO EXISTING
COOLING COILS, FILTERS, HUMIDIFIER, SUPPLY
FAN, CONTROLS, AND ALL ASSOCIATED
ACCESSORIES IN THEIR ENTIRETY.
DISCONNECT, REMOVE, AND DEMO EXISTING
SUPPLY AIR DUCTWORK, RETURN AIR
DUCTWORK, AND ALL ASSOCIATED
ACCESSORIES TO THE EXTENTS SHOWN.
DISCONNECT, REMOVE, AND DEMO EXISTING
PNEUMATIC VAV BOXES, CONTROLS,
PNEUMATIC TUBING AND ALL ASSOCIATED
ACCESSORIES IN THEIR ENTIRETY. MODIFY
ASSOCIATED DUCTWORK AS REQUIRED TO
CONNECT TO NEW VAV BOX.
EXISTING MAKE UP AIR UNIT TO REMAIN.
DISCONNECT, REMOVE, AND DEMO EXISTING
PNEUMATIC TUBING, CONTROLS, AND ALL
ASSOCIATED ACCESSORIES IN THEIR ENTIRETY.
EXISTING SUPPLY FAN TO REMAIN.
DISCONNECT, REMOVE, AND DEMO PNEUMATIC
TUBING, CONTROLS, AND ALL ASSOCIATED
ACCESSORIES IN THEIR ENTIRETY.
DISCONNECT, REMOVE, AND DEMO EXISTING
RETURN FAN, CONTROLS, AND ALL
ASSOCIATED ACCESSORIES IN THEIR ENTIRETY.
EXISTING EXHAUST FAN TO REMAIN.
DISCONNECT, REMOVE, AND DEMO PNEUMATIC
TUBING, CONTROLS, AND ALL ASSOCIATED
ACCESSORIES IN THEIR ENTIRETY.
EXISTING LOUVER TO REMAIN.
GENERAL NOTES
1. DISCONNECT, REMOVE, AND DEMO ALL
PREVIOUSLY ABANDONED DUCTWORK, PIPING,
FITTINGS, AND ALL ASSOCIATED ACCESSORIES
IN THEIR ENTIRETY IN ATTIC SPACE.
file no.
checked by drawn by consultant contract order no.
472/LCFMAINTPROJ
consultant job no.
20080.00
M a t r ix
472/19503.SMD
funding code sheet description
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L
A C
H R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N issue date
KEY PLAN
9/14/2023 FOR CONSTRUCTION
BUILDING 29C UPPER ATTIC
PLAN - MECHANICAL
DEMOLITION
N BUILDING 29C UPPER ATTIC PLAN - MECHANICAL DEMOLITION (ADD ALTERNATE #1)
SCALE: 1/8" = 1'-0"
0 1 5 10 20
M-306
DBP
CAT
X-HX SKID
(AHU COILS)
X-HX SKID
(FIN TUBE)
X-SC PUMP
X-HX
X-PUMP
X-XT
X-PUMP
X-HX
X-SC PUMP
X-AS
X-3-1/2" STM UP
X-2"
SC UP
X-1" HR UP
X-1" HR UP
X-1" HR UP
X-1" HR UP
X-1" HR UP
X-1" HR UP
X-1" HR UP
X-1" HR UP
X-1" HR UP
X-6" HR UP
X-2" HR
UP
X-1" HR UP
X-1" HR UP
P
X-2-1/2" HS
UP
X-2" HS UP
X-2" HS UP
X-3" HS UP
X-3" HS UP
X-2" HS UP
X-2" HS UP
X-2" HS UP
X-1" HS UP
X-1" HS UP
X-1" HS
X-1-1/4"
HS
X-1" HS UP
X-1" HS UP
X-1" HS
X-1" HS
X-1"
HS UP
X-1" HS UP
X-1" HS UP
X-1-1/2" HS
X-1-1/4" HS UP
X-1" HS UP
X-1-1/2" CW
X-1-1/2" CW
X-6" HR
X-1-1/2" HR
X-1-1/2" HR
X-3/4" STM UP
X-1-1/2"
STM UP
X-2-3/4"
STM UP
X-1"
SC UP
X-1"
SC UP
X-1-1/2"
STM
X-4" STM
X-6" STM
X-6" STM
X-6" STM
X-SC
X-SC
X-SC
X-3" STM
X-3" HR
X-2-1/2" HR X-3" HS
X-2-1/2" HS
X-2-1/2"
HR UP
X-3" HR UP
X-AS 6
X-3" HS UP X-2-1/2"
HS UP
X-PRV-1
X-PRV-2
X-4" STM
X-2-1/2" G
TO GAS SEVICE
X-2-1/2" G
X-2-1/2" G 4
DEMOLITION NOTES
DISCONNECT, REMOVE, AND DEMO EXISTING
HEAT EXCHANGER, AIR SEPARATOR, PIPING, AND
ALL ASSOCIATED ACCESSORIES IN THEIR
ENTIRETY.
DISCONNECT, REMOVE, AND DEMO EXISTING
CIRCULATION PUMP, CONTROLS, PIPING,
CONCRETE PADS, AND ALL ASSOCIATED
ACCESSORIES IN THEIR ENTIRETY.
EXISTING STEAM CONDENSATE PUMP TO REMAIN.
DISCONNECT, REMOVE, AND DEMO EXISTING HEAT
EXCHANGER SKID PACKAGE, CONTROLS, AND ALL
ASSOCIATED ACCESSORIES IN THEIR ENTIRETY.
DISCONNECT, REMOVE, AND DEMO PIPING AND
ALL ASSOCIATED ACCESSORIES TO THE EXTENTS
SHOWN.
DISCONNECT, REMOVE, AND DEMO EXISTING
IN-FLOOR HEATING SUPPLY PIPING, HEATING
RETURN PIPING AND ALL ASSOCIATED
ACCESSORIES IN THEIR ENTIRETY. CAP PIPING AT
CEILING PENETRATION.
DISCONNECT, REMOVE AND DEMO EXISTING
STEAM PIPING, CONDENSATE PIPING, AND ALL
ASSOCIATED ACCESSORIES TO THE EXTENTS
SHOWN.
DISCONNECT, REMOVE, AND DEMO EXISTING
EXPANSION TANK, PIPING AND ALL ASSOCIATED
ACCESSORIES IN THEIR ENTIRETY.
DISCONNECT, REMOVE, AND DEMO EXISTING MAKE
UP COLD WATER PIPING AND ALL ASSOCIATED
ACCESSORIES TO THE EXTENTS SHOWN.
DISCONNECT, REMOVE, AND DEMO EXITING STEAM
PRESSURE REDUCING VALVE, RELIEF VALVE, AND
ALL ASSOCIATED ACCESSORIES TO THE EXTENTS
SHOWN.
file no.
checked by drawn by consultant contract order no.
472/LCFMAINTPROJ
consultant job no.
20080.00
M a t r ix
472/19503.SMD
funding code sheet description
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L
A C
H R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N issue date
KEY PLAN
9/14/2023 FOR CONSTRUCTION
BUILDING 29B BASEMENT
PLAN - PIPING DEMOLITION
N BUILDING 29B BASEMENT PLAN - PIPING DEMOLITION (BASE BID)
M-307
DBP
CAT
SCALE: 1/4" = 1'-0"
0 1 5 10
ZONE # F-2
AREA = 2,252 SQ. FT.
(ABANDONED)
ZONE # F-2
AREA = 2,252 SQ. FT.
(ABANDONED)
ZONE # F-1
AREA = 1,762 SQ. FT.
(ABANDONED)
ZONE # F-1
AREA = 1,762 SQ. FT.
(ABANDONED)
ZONE # F-2
AREA = 2,050 SQ. FT.
(ABANDONED)
ZONE # F-2
AREA = 2,050 SQ. FT.
(ABANDONED)
ZONE # F-1
AREA = 1,925 SQ. FT.
(ABANDONED)
ZONE # F-1
AREA = 1,925 SQ. FT.
(ABANDONED)
ZONE # F-4
AREA = 1,125 SQ. FT.
(ABANDONED)
ZONE # F-3
AREA = 1,133 SQ. FT.
(ABANDONED)
ACTIVE ZONE
AREA = 800 SQ. FT.
ACTIVE ZONE
AREA = 800 SQ. FT.
1 1
2 2
ZONE # F-2
AREA = 2,252 SQ. FT.
(ABANDONED)
ZONE # F-2
AREA = 2,252 SQ. FT.
(ABANDONED)
ZONE # F-1
AREA = 1,762 SQ. FT.
(ABANDONED)
ZONE # F-1
AREA = 1,762 SQ. FT.
(ABANDONED)
ZONE # F-2
AREA = 2,050 SQ. FT.
(ABANDONED)
ZONE # F-2
AREA = 2,050 SQ. FT.
(ABANDONED)
ZONE # F-1
AREA = 1,925 SQ. FT.
(ABANDONED)
ZONE # F-1
AREA = 1,925 SQ. FT.
(ABANDONED)
ZONE # F-4
AREA = 1,125 SQ. FT.
(ABANDONED)
ZONE # F-3
AREA = 1,133 SQ. FT.
(ABANDONED)
ACTIVE ZONE
AREA = 800 SQ. FT.
ACTIVE ZONE
AREA = 800 SQ. FT.
1 1
2 2
DEMOLITION NOTES
EXISTING ABANDONED RADIANT FLOOR HEAT,
PIPING, AND ALL ASSOCIATED ACCESSORIES TO
REMAIN. PIPING TO BE CAPPED IN BASEMENT AT
RISER LOCATIONS.
EXISTING RADIANT FLOOR HEAT, PIPING, AND ALL
ASSOCIATED ACCESSORIES TO REMAIN AND BE
REUSED. DISCONNECT, REMOVE, AND DEMO
EXISTING CONTROLS, PNEUMATIC TUBING, AND
ALL ASSOCIATED ACCESSORIES.
file no.
checked by drawn by consultant contract order no.
472/LCFMAINTPROJ
consultant job no.
20080.00
M a t r ix
472/19503.SMD
funding code sheet description
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L
A C
H R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N issue date
KEY PLAN
9/14/2023 FOR CONSTRUCTION
BUILDING 29A BELOW FIRST
FLOOR PLAN - RADIANT
FLOOR DEMOLITION
N BUILDING 29A BELOW FIRST FLOOR PLAN - RADIANT FLOOR DEMOLITION (BASE BID)
SCALE: 1/8" = 1'-0"
0 1 5 10 20
M-308
ZONE # C-2
AREA = 478 SQ. FT
(ABANDONED)
ZONE # C-4
AREA = 106 SQ FT
(ABANDONED)
ZONE # C-2
AREA = 478 SQ. FT
(ABANDONED)
ZONE # C-3
AREA = 750 SQ. FT
(ABANDONED)
ZONE # C-4
AREA = 1005 SQ. FT
(ABANDONED)
ZONE # C-1
AREA = 455 SQ. FT
(ABANDONED)ZONE # C-1
AREA = 553 SQ. FT
(ABANDONED)
ZONE # C-1
AREA = 466 SQ. FT
(ABANDONED)
ZONE # C-1
AREA = 466 SQ. FT
(ABANDONED)
ZONE # C-2
AREA =561 SQ. FT
(ABANDONED) ZONE # C-2
AREA = 750 SQ. FT
(ABANDONED)
ACTIVE ZONE
AREA = 800 SQ. FT ACTIVE ZONE
AREA = 800 SQ. FT
M-309
1 1
2 2
X-2"ø
X-1-1/2"ø
X-1-1/4"ø
X-4"ø
X-2"ø X-1-1/4"ø
X-3"ø
X-1-1/4"ø
X-1-1/2"ø
X-2"ø
X-1-1/2"ø
X-2"ø
X-2"ø X-2-1/2"ø
X-1"ø
DEMOLITION NOTES
EXISTING ABANDONED RADIANT CEILING PANELS
AND ALL ASSOCIATED ACCESSORIES TO REMAIN.
PIPING TO BE CAPPED IN BASEMENT AT RISER
LOCATIONS. DISCONNECT, REMOVE, AND DEMO
EXISTING RADIANT CEILING PANEL PIPING,
IN-FLOOR HEAT PIPING, AND ALL ASSOCIATED
ACCESSORIES TO THE EXTENTS SHOWN IN
ATTIC.
EXISTING RADIANT CEILING PANELS, PIPING, AND
ALL ASSOCIATED ACCESSORIES TO REMAIN AND
BE REUSED. DISCONNECT, REMOVE, AND DEMO
EXISTING CONTROLS, PNEUMATIC TUBING, AND
ALL ASSOCIATED ACCESSORIES.
DISCONNECT, REMOVE, AND DEMO EXISTING
PNEUMATIC CONTROL VALVE, PNEUMATIC
TUBING, CONTROLS, AND ALL ASSOCIATED
ACCESSORIES IN THEIR ENTIRETY. MODIFY
EXISTING PIPING AS NEEDED FOR NEW CONTROL
VALVE CONNECTION.
DISCONNECT, REMOVE, AND DEMO EXISTING
3-WAY PNEUMATIC CONTROL VALVE, PNEUMATIC
TUBING, CONTROLS, AND ALL ASSOCIATED
ACCESSORIES IN THEIR ENTIRETY. MODIFY
EXISTING PIPING AS NEEDED FOR NEW CONTROL
VALVE CONNECTION.
EXISTING PUMP TO REMAIN. DISCONNECT,
REMOVE, AND DEMO EXISTING CONTROLS AND
ALL ASSOCIATED ACCESSORIES IN THEIR
ENTIRETY.
EXISTING HEAT EXCHANGER TO REMAIN.
EXISTING EXPANSION TANK TO REMAIN.
X-HX
X-ET
P P P P
P
PP
X-HR
X-HS
X-STM
X-CW
X-PRESSURE
GUAGE (TYP.)
X-SHUTOFF
VALVE (TYP.)
X-PUMP
(TYP. 2)
X-CONTROL
VALVE
X-3-WAY CONTROL VALVE
(TYP. 2)
X-BACK FLOW
PREVENTER
X-STRAINER
X-PRESSURE
REDUCING VALVE
X-PRESSURE
RELIEF VALVE
FTX-STEAM
TRAP
X-SC TO SC PUMP
FROM GYM / WORKOUT 1
FROM GYM / WORKOUT 2
TO GYM / WORKOUT 1
TO GYM / WORKOUT 2
file no.
checked by drawn by consultant contract order no.
472/LCFMAINTPROJ
consultant job no.
20080.00
M a t r ix
472/19503.SMD
funding code sheet description
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L
A C
H R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N issue date
KEY PLAN
9/14/2023 FOR CONSTRUCTION
BUILDING 29A FIRST FLOOR
PLAN - RADIANT CEILING
DEMOLITION
N BUILDING 29A FIRST FLOOR PLAN - RADIANT CEILING DEMOLITION (BASE BID)
SCALE: 1/8" = 1'-0"
0 1 5 10 20
M-309
DBP
CAT
1 MECHANICAL ROOM - PIPING DEMOLITION
SCALE: NTS
ZONE # C-4
AREA = 710 SQ. FT
(ABANDONED)
ZONE # C-3
AREA = 172 SQ. FT
(ABANDONED)
ZONE # C-4
AREA = 598 SQ. FT
(ABANDONED)
ZONE # C-3
AREA = 342 SQ. FT
(ABANDONED)
ZONE # C-1
AREA = 293 SQ. FT
(ABANDONED)
ZONE # C-2
AREA = 355 SQ. FT
(ABANDONED)
ZONE # C-2
AREA = 200 SQ. FT
(ABANDONED)
X-2"ø
X-4"ø
X-3/4"ø
X-1-1/4"ø
X-2"ø
X-2"ø
X-2-1/2"ø
X-1-1/2"øX-2"ø
X-1-1/2"ø
X-1-1/2"ø
X-1"ø
X-2"øX-1-1/2"ø
X-1-1/4"ø
X-1-1/2"ø
X-1"ø X-2"ø
X-1"ø
X-1"ø
X-1-1/4"ø
X-1-1/2"ø
X-2"ø
X-1-1/4"ø
X-2-1/2"ø
X-3/4"ø
X-2"ø
X-1-1/2"ø
1 1
1 1 1 1
DEMOLITION NOTES
EXISTING ABANDONED RADIANT CEILING PANELS
AND ALL ASSOCIATED ACCESSORIES TO REMAIN.
PIPING TO BE CAPPED IN BASEMENT AT RISER
LOCATIONS. DISCONNECT, REMOVE, AND DEMO
EXISTING RADIANT CEILING PANEL PIPING,
IN-FLOOR HEAT PIPING, AND ALL ASSOCIATED
ACCESSORIES TO THE EXTENTS SHOWN IN
ATTIC.
file no.
checked by drawn by consultant contract order no.
472/LCFMAINTPROJ
consultant job no.
20080.00
M a t r ix
472/19503.SMD
funding code sheet description
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L
A C
H R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N issue date
KEY PLAN
9/14/2023 FOR CONSTRUCTION
N BUILDING 29B FIRST FLOOR PLAN - RADIANT CEILING DEMOLITION (ADD ALTERNATE #1)
SCALE: 1/8" = 1'-0"
0 1 5 10 20
M-310
DBP
CAT
BUILDING 29B FIRST FLOOR
PLAN - RADIANT CEILING
DEMOLITION
ZONE # C-2
AREA = 1940 SQ. FT
(ABANDONED)
ZONE # C-2
AREA = 110 SQ. FT
(ABANDONED)
ZONE # C-2
AREA = 630 SQ. FT
(ABANDONED)
ZONE # C-1
AREA = 347 SQ. FT
(ABANDONED)
ZONE # C-1
AREA = 135 SQ. FT
(ABANDONED)
ZONE # C-4
AREA = 316 SQ. FT
(ABANDONED) ZONE # C-3
AREA = 540 SQ. FT
(ABANDONED)
ZONE # C-1
AREA = 132 SQ. FT
(ABANDONED)
X-3"ø
X-2"øX-1-1/2"ø
X-2"ø
X-4"ø
X-1-1/2"ø
X-1-1/2"ø X-1-1/4"ø
DEMOLITION NOTES
EXISTING ABANDONED RADIANT CEILING PANELS
AND ALL ASSOCIATED ACCESSORIES TO REMAIN.
PIPING TO BE CAPPED IN BASEMENT AT RISER
LOCATIONS. DISCONNECT, REMOVE, AND DEMO
EXISTING RADIANT CEILING PANEL PIPING,
IN-FLOOR HEAT PIPING, AND ALL ASSOCIATED
ACCESSORIES TO THE EXTENTS SHOWN IN
ATTIC.
file no.
checked by drawn by consultant contract order no.
472/LCFMAINTPROJ
consultant job no.
20080.00
M a t r ix
472/19503.SMD
funding code sheet description
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L
A C
H R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N issue date
KEY PLAN
9/14/2023 FOR CONSTRUCTION
N BUILDING 29C FIRST FLOOR PLAN - RADIANT CEILING DEMOLITION (ADD ALTERNATE #1)
SCALE: 1/8" = 1'-0"
0 1 5 10 20
M-311
DBP
CAT
BUILDING 29C FIRST FLOOR
PLAN - RADIANT CEILING
DEMOLITION
333333333333
3 3 3 3 3 3 3 3
3 3 3 3 3 3 3
3333333
3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3
333333
X-1-1/4"ø
HWR
X-1-1/4"ø
HWR
X-1-1/4"ø HWR X-1-1/4"ø
HWR
X-1-1/4"ø
HWR
X-1"ø HWS
(TYP.)
X-1"ø HWS
(TYP.)
X-1"ø HWS
(TYP.)
X-1"ø HWS
(TYP.)
X-1"ø HWS
(TYP.)
X-1"ø HWS
(TYP.)
X-1"ø HWS
(TYP.)
X-1"ø HWS
(TYP.)
X-1-1/4"ø
HWR
X-1-1/4"ø
HWR
X-1-1/4"ø
HWR
X-2" HWR
& HWR
X-2-1/2"ø HWR
X-2" HWS
& HWR
X-2-1/2"ø HWR
& HWS
X-STM HC
X-CC
X-STM HC
X-CC
X-STM HC
X-CC
X-STM HC
X-CC
X-COND
X-COND
X-CONCRETE PAD
X-CONCRETE PAD
X-COND
X-FIN TUBE X-FIN TUBE X-FIN TUBE X-FIN TUBE X-FIN TUBE X-FIN TUBE X-FIN TUBE
X-FIN TUBE
X-FIN TUBE
X-FIN TUBE X-FIN TUBE X-FIN TUBE X-FIN TUBE X-FIN TUBE X-FIN TUBE X-FIN TUBE X-FIN TUBE X-FIN TUBE X-FIN TUBE X-FIN TUBE X-FIN TUBE X-FIN TUBE
X-FIN TUBE
X-FIN TUBEX-FIN TUBEX-FIN TUBEX-FIN TUBEX-FIN TUBEX-FIN TUBE
X-FIN TUBEX-FIN TUBEX-FIN TUBE
X-FIN TUBE
X-FIN TUBEX-FIN TUBEX-FIN TUBEX-FIN TUBEX-FIN TUBEX-FIN TUBEX-FIN TUBEX-FIN TUBE
X-FIN TUBE
X-FIN TUBE
X-FIN TUBE X-FIN TUBE X-FIN TUBE X-FIN TUBE X-FIN TUBE X-FIN TUBE
X-FIN TUBE
X-FIN TUBE X-FIN TUBE X-FIN TUBE X-FIN TUBE X-FIN TUBE X-FIN TUBE X-FIN TUBE
X-FIN TUBE
X-FIN TUBE
X-FIN TUBEX-FIN TUBEX-FIN TUBEX-FIN TUBEX-FIN TUBEX-FIN TUBE
X-FIN TUBE
1T T T T
T T T
T
T
TTTT
TTTT
T
T T T
T T
T T T
T T T T
TTT
T
4 4 4 4 4
4444444
44444
4 4 4 4 4 4 4 4 4
4 4 4
4 4 4 4 4 4
4 4 4 4 4 4
44444
44444
5 5 5 5 5 5 5 5
5 5 5
5 5 5
X-DX1
X-DX1
X-DX 1
X-DX1
X-DX 1
X-DX
X-DX
X-DX
X-DX
DEMOLITION NOTES
DISCONNECT, REMOVE, AND DEMO EXISTING
CONDENSING UNIT, COOLING COIL, CONCRETE
PAD, REFRIGERANT PIPING, CONTROLS,
PNEUMATIC TUBING AND ALL ASSOCIATED
ACCESSORIES IN THEIR ENTIRETY.
DISCONNECT, REMOVE, AND DEMO EXISTING
STEAM HEATING COILS, STEAM PIPING, STEAM
CONDENSATE PIPING, CONTROLS, PNEUMATIC
TUBING, AND ALL ASSOCIATED ACCESSORIES IN
THEIR ENTIRETY.
EXISTING FIN TUBE TO REMAIN. EXISTING FIN
TUBE THROUGHOUT THE BUILDING TO REMAIN
UNLESS OTHERWISE NOTED.
DISCONNECT REMOVE, AND DEMO EXISTING
PNEUMATIC CONTROL VALVE, PNEUMATIC
TUBING, CONTROLS, AND ALL ASSOCIATED
ACCESSORIES. MODIFY HEATING PIPING AS
REQUIRED TO INSTALL NEW SHUTOFF VALVES,
CONTROL VALVES, AND BALANCE VALVE.
REMOVE EXISTING SHUTOFF VALVES AND
BALANCE VALVE.
DISCONNECT, REMOVE, AND DEMO EXISTING
WALL MOUNTED THERMOSTATS, CONTROLS,
PNEUMATIC TUBING AND ALL ASSOCIATED
ACCESSORIES IN THEIR ENTIRETY. PATCH,
PRIME, AND PAINT LOCATIONS WHERE
THERMOSTATS WERE REMOVED TO MATCH
EXISTING.
GENERAL NOTES
1. THERMOSTATS ARE LOCATED IN THE
OCCUPIED SPACE. THERMOSTATS SHOWN
ON THIS PLAN FOR CLARITY.
2. DISCONNECT, REMOVE, AND DEMO ALL
PREVIOUSLY ABANDONED PIPING, FITTINGS,
AND ALL ASSOCIATED ACCESSORIES IN
THEIR ENTIRETY IN ATTIC SPACE.
file no.
checked by drawn by consultant contract order no.
472/LCFMAINTPROJ
consultant job no.
20080.00
M a t r ix
472/19503.SMD
funding code sheet description
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L
A C
H R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N issue date
KEY PLAN
9/14/2023 FOR CONSTRUCTION
BUILDING 29A LOWER ATTIC
PLAN - PIPING DEMOLITION
N BUILDING 29A LOWER ATTIC PLAN - PIPING DEMOLITION (BASE BID)
SCALE: 1/8" = 1'-0"
0 1 5 10 20
M-312
TT
T
T
T
T
T
T
T T
T T
T
T
T
T
T
T
T X-3/4"ø
HWS DN
X-2-1/2" HS
& 3" HR
X-3/4"
HS DN
X-3" HR DN
TO X-CONV
X-2-1/2" HS
DN TO X-CONV
X-3/4" HS & HR
X-2" HS &
1" HR
X-1" HS DN
X-3/4" HS & HR
(TYP.)
X-3" HS &
1" HR
X-3/4" HR DN
X-2" HS &
1" HR
X-3" HS
X-3/4" HS
& HR
X-3/4" HS &
HR (TYP.)
X-3/4" HS
& HR UP
X-2" HS
X-1" HS DN
X-1" HS DN
X-1" HR DN
X-3/4" HS &
HR (TYP.)
X-1" HS & HR
X-1" HS & HR
X-1" HS & HR
X-1-1/4" HS
& 2" HR
X-3/4" HS DN
X-FIN TUBE
X-3/4" HS DN X-3/4" HR DN
X-2" HS &
2-1/2" HR
X-3/4" HS
& HR
X-3/4" HS &
HR (TYP.)
X-3/4" HS
& HR UP
X-1-1/2" HS
& 2-1/2" HR
X-1-1/2" HS
& 2-1/2" HR
X-3/4" HS
& HR UP
X-1" HS DN
X-FIN TUBE
X-1" HS DN
X-1" HS DN
X-1" HS DN
X-1" HS DN
X-1" HS DN
X-1" HS DN
X-1" HR DN
X-1" HS
& HR
X-3/4" HS &
HR (TYP.)
X-1" HS
& HR
X-1-1/4" HS
& 2-1/2" HR
X-1-1/4" HS
& 2-1/2" HR
X-3/4" HS
& HR UP
X-1" HS & 3" HR
X-1" HS &
2-1/2" HR
X-3/4"
HS DN
X-3/4"
HR DN
X-3/4"
HS DNX-3/4"
HS DN
X-3/4" HS
& HR UP
X-3/4" HS
& HR UP
X-3" HS DN TO
X-CONV
T
X-2-1/2"
& 3" HR
X-FIN
TUBE
X-2-1/2"
HRX-2-1/2"
HR
X-2-1/2" HR DN
TO X-CONV
X-3/4"
HS & HR
6 6
6 6 6
X-2-1/2"ø HWR
& HWS
7 7
X-CONCRETE PAD
X-COND
X-COND
X-CUH
X-CUH
X-CUH
X-CUH
X-CUH
(ABANDONED)
X-AC
X-AC
X-AC
X-AC
X-FIN TUBE
X-FIN TUBE
X-FIN TUBE
X-FIN TUBE
X-FIN TUBE
X-FIN TUBE
X-FIN TUBE
X-FIN TUBE
X-FIN TUBE
X-FIN TUBE
X-FIN TUBE
X-FIN TUBE
X-FIN TUBE
X-FIN TUBE
X-FIN TUBE
X-FIN TUBE X-FIN TUBE
X-FIN TUBE
X-FIN TUBE
X-FIN TUBE
X-FIN TUBE
X-FIN TUBE
X-FIN TUBE
X-FIN TUBE
X-FIN TUBE
X-FIN TUBE
X-FIN TUBE
X-CU
X-DX2
X-DX2
X-2-1/2" G
TO BASEMENT
X-2-1/2"
G UP
DEMOLITION NOTES
DISCONNECT, REMOVE, DEMO EXISTING
PNEUMATIC VAV BOXES, CONTROLS, PNEUMATIC
TUBING AND ALL ASSOCIATED ACCESSORIES IN
THEIR ENTIRETY. MODIFY ASSOCIATED PIPING AS
REQUIRED TO CONNECT TO NEW VAV BOX.
DISCONNECT, REMOVE, AND DEMO EXISTING
CONDENSER, CONTROLS, PNEUMATIC TUBING,
CONCRETE PAD, REFRIGERANT PIPING, AND ALL
ASSOCIATED ACCESSORIES IN THEIR ENTIRETY.
DISCONNECT, REMOVE, AND DEMO EXISTING
ABANDONED CABINET UNIT HEATER, PNEUMATIC
TUBING, CONTROLS, PIPING AND ALL
ASSOCIATED ACCESSORIES IN THEIR ENTIRETY.
DISCONNECT, REMOVE, AND DEMO EXISTING
HEATING WATER SUPPLY PIPING, HEATING
WATER RETURN PIPING, AND ALL ASSOCIATED
ACCESSORIES TO THE EXTENTS SHOWN.
EXISTING CABINET UNIT HEATER TO REMAIN.
DISCONNECT, REMOVE, AND DEMO EXISTING
CONTROLS, CONTROL VALVE, PNEUMATIC
TUBING, AND ALL ASSOCIATED ACCESSORIES IN
THEIR ENTIRETY.
EXISTING FIN TUBE TO REMAIN. EXISTING FIN
TUBE THROUGHOUT THE BUILDING TO REMAIN
UNLESS OTHERWISE NOTED.
DISCONNECT, REMOVE, AND DEMO EXISTING
PNEUMATIC THERMOSTAT, PNEUMATIC TUBING,
AND ALL ASSOCIATED PNEUMATIC TUBING IN
THEIR ENTIRETY.
EXISTING CONDENSING UNITS TO REMAIN.
EXISTING AIR CONDITIONING UNITS TO REMAIN.
DISCONNECT AND MODIFY EXISTING HEATING
PIPING AS REQUIRED TO INSTALL NEW SHUTOFF
VALVES, CONTROL VALVES, AND BALANCE
VALVE. REMOVE EXISTING VALVES WHERE
APPLICABLE.
GENERAL NOTES
1. THERMOSTATS ARE LOCATED IN THE
OCCUPIED SPACE. THERMOSTATS SHOWN
ON THIS PLAN FOR CLARITY.
2. DISCONNECT, REMOVE, AND DEMO ALL
PREVIOUSLY ABANDONED PIPING, FITTINGS,
AND ALL ASSOCIATED ACCESSORIES IN
THEIR ENTIRETY IN ATTIC SPACE.
file no.
checked by drawn by consultant contract order no.
472/LCFMAINTPROJ
consultant job no.
20080.00
M a t r ix
472/19503.SMD
funding code sheet description
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L
A C
H R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N issue date
KEY PLAN
9/14/2023 FOR CONSTRUCTION
BUILDING 29B LOWER ATTIC
PLAN - PIPING DEMOLITION
N BUILDING 29B LOWER ATTIC PLAN - PIPING DEMOLITION (ADD ALTERNATE #1)
SCALE: 1/8" = 1'-0"
0 1 5 10 20
M-313
| Sheets and Views |
| M-000-2008000-T-000 |
| M100-2008000-M-100 |
| M300-2008000-M-300 |
| M301-2008000-M-301 |
| M302-2008000-M-302 |
| M303-2008000-M-303 |
| M304-2008000-M-304 |
| M305-2008000-M-305 |
| M306-2008000-M-306 |
| M307-2008000-M-307 |
| M308-2008000-M-308 |
| M309-2008000-M-309 |
| M310-2008000-M-310 |
| M311-2008000-M-311 |
| M312-2008000-M-312 |
| M313-2008000-M-313 |
| M314-2008000-M-314 |
| M315-2008000-M-315 |
| M316-2008000-M-316 |
| M317-2008000-M-317 |
| M318-2008000-M-318 |
| M319-2008000-M-319 |
| M320-2008000-M-319 |
| M400-2008000-M-400 |
| M401-2008000-M-401 |
| M402-2008000-M-402 |
| M403-2008000-M-403 |
| M404-2008000-M-404 |
| M405-2008000-M-405 |
| M406-2008000-M-406 |
| M600-2008000-M-600 |
| M601-2008000-M601 |
| M602-2008000-M602 |
| M603-2008000-M603 |
| M604-2008000-M604 |
| M605-2008000-M605 |
| M606-2008000-M606 |
| M607-2008000-M607 |
| M608-2008000-M608 |
| M609-2008000-M-609 |
| M610-2008000-M-610 |
| M611-2008000-M-611 |
| M800-2008000-M-800 |
| M801-2008000-M-801 |
| M802-2008000-M-802 |
| M900-2008000-M-900 |
File details come from the government source that posted it. Updated .