Corbin_Park_-_Bid_Set_Drawings.pdf
PDF 35 MB Posted
- Solicitation number
- 26-B-20KW
- Issued by
- Volusia County, Florida
About this file
This is a bid set drawing document prepared by Tetra Tech for the City of New Smyrna Beach's Corbin Park Stormwater Management Improvements project, a federally funded recovery initiative through Volusia County's Office of Recovery and Resiliency. The project encompasses stormwater infrastructure improvements along Corbin Park Road and adjacent local roadways including Davis Drive, Juanita Drive, Swoope Drive, Doster Drive, Paige Avenue, Burma Road, Robin Road, and S. Walker Drive in New Smyrna Beach, Florida. The comprehensive construction plans include storm drainage pipe installations ranging from 12 inches to 48 inches in diameter, storm structure construction with multiple inlet and manhole configurations, pavement restoration work, utility coordination across water mains and force mains, and site restoration including sidewalk, curb, and driveway replacements. The drawing set contains detailed plan and profile sheets organized by roadway segment, alignment geometry data, pipe and structure tables with specifications, and standard civil details for construction implementation. Construction operations are limited to 7:00 a.m. to 7:00 p.m., Monday through Friday, with directional drilling and paving operations prohibited on Fridays, Saturdays, Sundays, or days preceding holidays without written approval from the County Development Engineer.
The project is funded through a U.S. Department of Housing and Urban Development Community Development Block Grant for Disaster Recovery (CDBG-DR) in response to Hurricane Ian damage suffered in September 2022. All work is subject to Federal Labor Standards including Davis-Bacon Act prevailing wage requirements, Copeland Act anti-kickback provisions, bonding requirements per 24 CFR 85.36, and Section 3 and M/WBE compliance. The prime contractor is responsible for wage compliance enforcement and submission of weekly certified payroll reports and may be held liable for wage restitution. The contractor must obtain all required permits before construction begins, coordinate with multiple utility providers including New Smyrna Beach Utilities and Florida Public Utilities, maintain temporary services as necessary, and ensure restoration of all disturbed areas within the City and County right-of-way to original condition or better. Pre-construction coordination is required with Volusia County Development Engineering at least 24 hours prior to construction start, with seven days' advance notice required for any road, lane, or sidewalk closures.
View the file
Other files
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DAVIS DR
JUANITA DR
SWOOPE DR
DOSTER DR
LIVE OAK DR
PINE ISLAND DR
PAIGE AVE
DOLORES ST
HAWKS COVE CIR
ROBIN RD
ANNETTE RD
TROPHY HUNTER TR
SIERRA DRUNDEVELOPED ROW
CAROLYN ST
JUDY ST
S W
ALKER DR
CORBIN PARK RD
HAWKS COVE CIR
BURMA RD
BURM
A RD
MAGNOLIA DR
© 2023 Microsoft Corporation © 2023 TomTom
N
PROJECT LOCATION MAP
SCALE: N.T.S.
CITY OF NEW SMYRNA BEACH
MAYOR
FRED CLEVELAND
VALLI PERRINE
ZONE 1
CITY MANAGER
KEVIN COWPER
INTERIM CITY CLERK
SHARON TAYLOR-HARDING
COMMISSIONERS
LISA MARTIN
ZONE 2
JASON MCGUIRK
ZONE 3
BRIAN ASHLEY
ZONE 4
ENGINEERING BUSINESS NO. 2429
www.tetratech.com
CLIENT INFORMATION:PROJECT LOCATION:
PROJECT DESCRIPTION / NOTES:
Tt PROJECT No.:
CLIENT PROJECT No.:
ISSUED:
CITY OF NEW SMYRNA BEACH
CORBIN PARK STORMWATER
MANAGEMENT IMPROVEMENTS
NEW SMYRNA BEACH, FLORIDA
200-41704-22002
CITY OF NEW SMYRNA BEACH
210 SAMS AVE.
NEW SMYRNA BEACH, FLORIDA 32168
201 EAST PINE ST, SUITE 1000
ORLANDO, FLORIDA 32801
PHONE: 407-839-3955
MAY 2025 - BID SUBMITTAL
VICINITY MAP:
PROJECT
LOCATION
PROJECT INCLUDES IMPROVEMENTS TO STORMWATER INFRASTRUCTURE ALONG
CORBIN PARK ROAD, AND OTHER LOCAL ROADWAYS.
PROPOSED PROJECT LIMITS
N
SHEET INDEX
SH. NO SHEET TITLE
G-000 COVER
G-001 GENERAL NOTES
G-002 GENERAL NOTES
G-003 LEGENDS & ABBREVIATIONS
C-100 EXISTING CONDITIONS & DEMOLITION KEY PLAN
C-101 CORBIN PARK ROAD EXISTING CONDITIONS & DEMOLITION PLAN
C-102 CORBIN PARK ROAD EXISTING CONDITIONS & DEMOLITION PLAN
C-103 CORBIN PARK ROAD EXISTING CONDITIONS & DEMOLITION PLAN
C-104 DAVIS DRIVE EXISTING CONDITIONS & DEMOLITION PLAN
C-105 JUANITA DRIVE EXISTING CONDITIONS & DEMOLITION PLAN
C-106 SWOOPE DRIVE EXISTING CONDITIONS & DEMOLITION PLAN
C-107 DOSTER DRIVE EXISTING CONDITIONS & DEMOLITION PLAN
C-108 PAIGE AVENUE EXISTING CONDITIONS & DEMOLITION PLAN
C-109 BURMA ROAD EXISTING CONDITIONS & DEMOLITION PLAN
C-110 ROBIN ROAD EXISTING CONDITIONS & DEMOLITION PLAN
C-111 S. WALKER DRIVE EXISTING CONDITIONS & DEMOLITION PLAN
C-200 ALIGNMENT GEOMETRY
C-201 KEY PLAN
C-202 STORM PIPE TABLES
C-203 STORM STRUCTURE TABLES
C-204 CORBIN PARK ROAD PLAN & PROFILE
C-205 CORBIN PARK ROAD PLAN & PROFILE
C-206 CORBIN PARK ROAD PLAN & PROFILE
C-207 CORBIN PARK ROAD PLAN & PROFILE
C-208 CORBIN PARK ROAD PLAN & PROFILE
C-209 CORBIN PARK ROAD PLAN & PROFILE
C-210 DAVIS DRIVE PLAN & PROFILE
C-211 DAVIS DRIVE PLAN & PROFILE
C-212 JUANITA DRIVE PLAN & PROFILE
C-213 JUANITA DRIVE PLAN & PROFILE
C-214 SWOOPE DRIVE PLAN & PROFILE
C-215 SWOOPE DRIVE PLAN & PROFILE
C-216 DOSTER DRIVE PLAN & PROFILE
C-217 DOSTER DRIVE PLAN & PROFILE
C-218 PAIGE AVENUE PLAN & PROFILE
C-218A PAIGE AVENUE & CORBIN PARK ROAD INTERSECTION
C-219 PAIGE AVENUE PLAN & PROFILE
C-220 BURMA ROAD PLAN & PROFILE
C-221 BURMA ROAD PLAN & PROFILE
C-222 S. WALKER DRIVE PLAN & PROFILE
C-223 ROBIN ROAD PLAN & PROFILE
C-501 CIVIL DETAILS
C-502 CIVIL DETAILS
C-503 CIVIL DETAILS
C-504 CIVIL DETAILS
C-505 CIVIL DETAILS
C-506 CIVIL DETAILS
C-507 CIVIL DETAILS
C-508 CIVIL DETAILS
G-001
G
EN
ER
AL
N O
TE
S
JW
ARM
MDT
GENERAL NOTES
48 HOURS BEFORE DIGGING
1-800-432-4770
SUNSHINE STATE ONE CALL CENTER
CALL 811
TOLL FREE
OR
GENERAL:
1. BENCHMARKS FOR CONSTRUCTION HAVE BEEN PROVIDED ON SHEET C-100.
2. ALL FIELD LAYOUT SURVEYING FOR CONSTRUCTION AND LOCATING EASEMENTS, ROW, AND PROPERTY LINES FOR THIS PROJECT SHALL BE PROVIDED BY THE CONTRACTOR AT THEIR EXPENSE; UNDER THE DIRECTION OF A LICENSED PROFESSIONAL LAND
SURVEYOR.
3. BENCHMARK DATUM IS NATIONAL NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 88).
4. TOPOGRAPHIC INFORMATION SHOWN ON THESE PLANS WERE TAKEN FROM SURVEY PROVIDED BY: TETRA TECH, 201 E. PINE ST., SUITE 1000, ORLANDO, FL 32801. (407) 839-3955
5. THIS PROJECT IS IN FUNDED IN PART THROUGH VOLUSIA COUNTY. FUNDING WILL BE MANAGED AND COORDINATED BY THE
COUNTY.
6. ALL LABOR, MATERIALS, AND METHODS OF CONSTRUCTION SHALL BE IN STRICT ACCORDANCE WITH THE MINIMUM ENGINEERING AND CONSTRUCTION STANDARDS ADOPTED BY THE CITY OF NEW SMYRNA BEACH AND NEW SMYRNA BREACH UTILITIES (NSBU).
WHERE CONFLICTS OR OMISSIONS EXIST, THE CITY OF NEW SMYRNA BEACH OR NSBU STANDARDS SHALL DICTATE.
SUBSTITUTIONS AND DEVIATION FROM PLANS AND SPECIFICATIONS SHALL BE PERMITTED ONLY WHEN WRITTEN APPROVAL HAS
BEEN ISSUED BY THE ENGINEER.
7. SHOP DRAWINGS OF ALL MATERIALS BEING USED SHALL BE SUBMITTED TO THE ENGINEER, CITY, NSBU, AND COUNTY AS
APPLICABLE FOR APPROVAL PRIOR TO INSTALLATION.
8. IT WILL BE THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE THAT ALL REQUIRED PERMITS ARE OBTAINED AND IN-HAND BEFORE BEGINNING ANY CONSTRUCTION. NO CONSTRUCTION OR FABRICATION OF ANY ITEM SHALL BEGIN UNTIL THE CONTRACTOR HAS RECEIVED ALL PLANS AND ANY OTHER DOCUMENTATION FROM ALL OF THE PERMITTING AND ANY OTHER REGULATORY AUTHORITIES. ANY PENALTIES, STOP WORK ORDERS OR ADDITIONAL WORK RESULTING FROM THE CONTRACTOR BEING IN VIOLATION OF THE REQUIREMENTS ABOVE, SHALL BE FULLY BORNE BY THE CONTRACTOR.
9. THE LOCATION OF ALL EXISTING UTILITIES AND STORM DRAINAGE SHOWN ON THE PLANS HAVE BEEN DETERMINED FROM THE BEST INFORMATION AVAILABLE AND ARE GIVEN FOR THE CONVENIENCE OF THE CONTRACTOR. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR INACCURACY. PRIOR TO THE START OF ANY CONSTRUCTION ACTIVITY IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE VARIOUS UTILITIES AND TO MAKE THE NECESSARY ARRANGEMENTS FOR ANY RELOCATION OF THESE UTILITIES WITH THE OWNER OF THE UTILITY. THE CONTRACTOR SHALL EXERCISE CAUTION WHEN CROSSING UNDERGROUND UTILITIES, WHETHER SHOWN ON THE PLAN OR LOCATED BY THE UTILITY COMPANY. ALL UTILITIES WHICH INTERFERE WITH THE PROPOSED CONSTRUCTION SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FIRST. ANY FEES ASSOCIATED WITH UTILITY RELOCATIONS SHALL BE BORNE IN ACCORDANCE WITH RESPECTIVE UTILITY COMPANY STANDARDS. IT IS REQUESTED THAT UTILITY COMPANIES MOVE THEIR PARTICULAR UTILITIES. ANY DELAY OR INCONVENIENCE CAUSED TO THE CONTRACTOR BY THE RELOCATION OF THE VARIOUS UTILITIES SHALL BE INCIDENTAL TO THE CONTRACT AND NO EXTRA
COMPENSATION WILL BE ALLOWED.
10. THE SEQUENCE OF CONSTRUCTION SHALL BE SUCH THAT ALL UNDERGROUND INSTALLATIONS OF EVERY KIND, INCLUDING LANDSCAPE SPRINKLERS, SHALL BE PLACED BENEATH THE PAVEMENT AND ITS EDGES PRIOR TO THE CONSTRUCTION OF THE PAVEMENT. THE PAVEMENT SHALL NOT BE CUT WITHOUT PRIOR APPROVAL OF THE CITY OF NEW SMYRNA BEACH AND/OR VOLUSIA
COUNTY, DEPENDING ON RIGHT-OF-WAY OWNERSHIP.
11. THE CONTRACTOR SHALL NOTIFY THE ENGINEER AT LEAST 48 HOURS PRIOR TO BEGINNING CONSTRUCTION AND AT LEAST 48 HOURS HOURS BEFORE REQUIRED INSPECTION ON EACH AND EVERY PHASE OF WORK. THE CONTRACTOR SHALL NOTIFY THE ENGINEER A MINIMUM OF 48 HOURS NOTICE PRIOR TO ANY SCHEDULED TESTING. NO PRESSURE TESTING, OR FINAL TESTING WILL
BE ACCEPTED UNLESS WITNESSED BY THE ENGINEER'S REPRESENTATIVE.
12. ALL CONTRACTORS, CITY REPRESENTATIVES, COUNTY REPRESENTATIVES, AND UTILITY COMPANIES ARE RESPONSIBLE FOR THEIR RESPECTIVE SURVEYING AND LAYOUT FROM BENCHMARK PROVIDED ON CONSTRUCTION PLANS. ANY SURVEY MONUMENTATION DISTURBED DURING CONSTRUCTION SHALL BE REPLACED UPON COMPLETION OF THE WORK BY A REGISTERED LAND SURVEYOR.
13. CONTRACTOR SHALL EXCAVATE TEST PITS FOR THE PURPOSE OF PROTECTING AND CONFIRMING LOCATION AND DEPTH OF EXISTING UTILITIES OR STRUCTURES IN ADVANCE OF CONSTRUCTION. TEST PITS SHALL BE DUG BY HAND AND BACKFILLED IMMEDIATELY AFTER THEIR PURPOSE HAS BEEN SATISFIED AND SHALL NOT REMAIN OPEN DURING NONWORKING HOURS.
14. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PREVENTING ANY CONSTRUCTION ACTIVITIES FROM TAKING PLACE OUTSIDE OF THE PROJECT LIMITS. ANY ON-SITE OR OFFSITE AREAS DISTURBED SHALL BE RESTORED TO ORIGINAL CONDITION OR BETTER.
15. PRIOR TO BID PREPARATION, THE CONTRACTOR MUST BECOME FAMILIAR WITH THE OVERALL SITE CONDITIONS AND PERFORM ADDITIONAL INVESTIGATIONS AS DETERMINED NECESSARY TO UNDERSTAND THE LIMIT AND DEPTH OF EXPECTED ORGANIC SILT PEAT AREAS, ADEQUACY OF EXISTING MATERIALS AS FILL, DEWATERING REQUIREMENTS, CLEAN FILL REQUIRED FROM OFFSITE, AND MATERIALS TO BE DISPOSED OF OFFSITE, ALL OF WHICH WILL AFFECT THEIR PRICING. ANY DELAY, INCONVENIENCE, OR EXPENSE CAUSED TO THE CONTRACTOR DUE TO INADEQUATE INVESTIGATION OF EXISTING CONDITIONS SHALL BE INCIDENTAL TO THE CONTRACT, AND NO EXTRA COMPENSATION WILL BE ALLOWED. THE MATERIALS ANTICIPATED TO BE ENCOUNTERED DURING CONSTRUCTION MAY REQUIRE DRYING PRIOR TO USE AS BACKFILL, AND THE CONTRACTOR MAY HAVE TO IMPORT MATERIALS, AT NO EXTRA COST, FROM OFFSITE TO MEET THE REQUIREMENTS FOR COMPACTION AND PROPER FILL.
16. REPLACE IN-KIND SIDEWALKS, DRIVES, LAWNS, MAILBOXES, SPRINKLERS, ETC., REMOVED OR DAMAGED DURING CONSTRUCTION
OR THE STAGING OF MATERIAL OR DEWATERING.
17. ROAD RESTORATION SHALL BE IN ACCORDANCE WITH THE CONTRACT DOCUMENTS.
18. ANY REMOVED OR DAMAGED PAVEMENT MARKINGS; INCLUDING, BUT NOT LIMITED TO,SOLID LINES, STOP BARS, ARROWS, AND
OTHER STRIPING SHALL BE REPLACED WITH THERMOPLASTIC.
19. ALL DIRT AND DEBRIS TRACKED MUST BE CLEANED UP AND BROOMED DAILY. IMPLEMENT DUST CONTROL IN ACCORDANCE WITH
THE CONTRACT DOCUMENTS.
20. EROSION AND SEDIMENTATION CONTROL SHALL BE IN ACCORDANCE WITH SECTION 01568.
21. EARTHWORK, GRADING AND STABILIZATION SHALL BE IN ACCORDANCE WITH SECTION 02200.
22. ALL STORMWATER STRUCTURES SHALL HAVE A TWO (2) FOOT SUMP DEPTH AND A WEEP HOLE IN THE STRUCTURE BOTTOM, UNLESS OTHERWISE SPECIFIED IN THE DRAWINGS.
23. NOTIFY VOLUSIA COUNTY DEVELOPMENT ENGINEERING DIVISION AT (386) 736-5926 A MINIMUM OF 24 HOURS PRIOR TO THE START OF CONSTRUCTION. FAILURE OF THE PERMITTEE TO OBTAIN THE APPROPRIATE INSPECTIONS PRIOR TO PROCEEDING WITH WORK SHALL NOT RELIEVE THE PERMITTEE FROM REEXCAVATION OR OTHER MEASURES NECESSARY FOR THE INSPECTION OF WORK.
24. VOLUSIA COUNTY TRAFFIC ENGINEERING (386) 736-5968 IS NOT A MEMBER OF SUNSHINE ONE CALL. WHEN REQUESTING LOCATES, PLEASE PROVIDE A MINIMUM ADVANCED NOTIFICATION OF TWO (2) BUSINESS DAYS PRIOR TO PROPOSED WORK.
25. COORDINATION WITH VOLUSIA COUNTY ENGINEERING'S INSPECTOR JIM PRICE AT (386) 561-8666 IS REQUIRED WITH A MINIMUM ADVANCED NOTICE OF SEVEN (7) DAYS PRIOR TO ANY SIDEWALK, LANE OR ROAD CLOSURE (INCLUDING FLAGGING OPERATIONS).
26. OPERATIONS SHALL NORMALLY BE CONDUCTED 7:00 A.M. TO 7:00 P.M., MONDAY THROUGH FRIDAY. ANY DEVIATION FROM THESE HOURS REQUIRES PRIOR APPROVAL FROM THE CITY OR COUNTY DEVELOPMENT ENGINEER. EMERGENCY REPAIRS ARE EXCLUDED
FROM THIS TIME RESTRICTION.
27. ALL EXISTING SIDEWALKS SHALL EITHER REMAIN OPEN OR BE PROVIDED A TEMPORARY WALKWAY IN ACCORDANCE WITH THE CURRENT VERSION OF FLORIDA DEPARTMENT OF TRANSPORTATION STANDARD INDEX NO. 102-660. ANY DAMAGE TO SIDEWALKS SHALL BE REPAIRED AND/OR REPLACED IN LIKE KIND BY THE CONTRACTOR. NEW SIDEWALKS AND SECTIONS THROUGH DRIVEWAYS
MUST BE AT A 2% MAXIMUM CROSS SLOPE PER ADA STANDARDS.
28. STAGING OF CONSTRUCTION VEHICLES OR MATERIALS IS NOT PERMITTED WITHIN THE COUNTY RIGHT-OF-WAY OR ON PEDESTRIAN WALKWAYS AND PATHS. THERE SHALL BE NO OVERNIGHT CONSTRUCTION VEHICLE RELATED PARKING, CONSTRUCTION MATERIAL
PLACEMENT OR STORAGE OF ANY KIND PERMITTED WITHIN THE COUNTY RIGHT-OF-WAY.
29. NO TRENCH OR EXCAVATION SHALL BE LEFT OPEN OR UNATTENDED OVERNIGHT, UNLESS APPROVED BY THE CITY/COUNTY DEVELOPMENT ENGINEERING INSPECTOR. EXCAVATIONS SHALL MEET THE DROP OFF PROTECTION REQUIREMENTS OF THE LATEST
FDOT DESIGN STANDARD INDEX NO. 102-600.
30. RESTORATION SHALL BE REQUIRED FOR ANY DAMAGE TO SIDEWALKS, CURBS, OR OTHER EXISTING STRUCTURES IN THE RIGHT-OF-WAY. ALL DISTURBED AREAS WITHIN THE CITY/COUNTY RIGHT OF WAY SHALL BE RE-GRADED AND SODDED. SEED AND
MULCH IS NOT AN ACCEPTABLE ALTERNATIVE TO SODDING.
31. CONTRACTOR TO COORDINATE WITH THE CITY/COUNTY FOR RIGHT OF ENTRY FOR CONSTRUCTION OUTSIDE OF RIGHT- OF-WAY.
SPILL CONTROL NOTES:
1. IN ADDITION TO THE GOOD HOUSEKEEPING AND MATERIAL MANAGEMENT PRACTICES DISCUSSED IN THE PREVIOUS NOTES OF THIS
PLAN, THE FOLLOWING PRACTICES WILL BE FOLLOWED FOR SPILL PREVENTION AND CLEANUP:
a. MANUFACTURERS' RECOMMENDED METHODS FOR SPILL CLEANUP WILL BE CLEARLY POSTED AND SITE PERSONNEL WILL BE MADE AWARE OF THE PROCEDURES AND THE LOCATION OF THE INFORMATION AND CLEANUP SUPPLIES.
b. ALL SPILLS WILL BE CLEANED UP IMMEDIATELY AFTER DISCOVERY.
c. SPILLS OF TOXIC OR HAZARDOUS MATERIAL WILL BE REPORTED TO THE APPROPRIATE STATE OR LOCAL GOVERNMENT
AGENCY, REGARDLESS OF SIZE.
d. THE SPILL PREVENTION PLAN WILL BE ADJUSTED TO INCLUDE MEASURES TO PREVENT THIS TYPE OF SPILL FROM REOCCURRING AND HOW TO CLEAN UP THE SPILL IF THERE IS ANOTHER ONE. A DESCRIPTION OF THE SPILL, WHAT CAUSED IT, AND THE CLEANUP MEASURES WILL ALSO BE INCLUDED.
e. THE SITE SUPERINTENDENT RESPONSIBLE FOR THE DAY-TO-DAY SITE OPERATIONS WILL BE THE SPILL PREVENTION AND
CLEANUP COORDINATOR.
OTHER UTILITY INFORMATION:
1. THE CONTRACTOR SHALL PROTECT UTILITIES AND OTHER IMPROVEMENTS SHOWN ON THESE PLANS AND OTHER UTILITIES AND OTHER IMPROVEMENTS NOT SHOWN. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIR OF UTILITIES AND OTHER IMPROVEMENTS DAMAGED DURING CONSTRUCTION AS DIRECTED BY THE ENGINEER, AT NO ADDITIONAL COST TO THE OWNER, AND SHALL MAINTAIN SUFFICIENT PROTECTION TO UTILITIES REQUIRED TO PROTECT THEM FROM DAMAGE AND TO PROTECT THE
PUBLIC DURING CONSTRUCTION.
2. THE CONTRACTOR SHALL NOTIFY UTILITY COMPANIES WHICH MAY HAVE THEIR UTILITIES WITHIN THE CONSTRUCTION AREAS TO LOCATE THEIR FACILITIES IN THE FIELD FORTY-EIGHT (48) HOURS PRIOR TO BEGINNING CONSTRUCTION.
3. FOR CONFLICT ADJUSTMENTS OF PROPOSED WATER AND SEWER FORCE MAIN, PIPE DEFLECTION SHALL MEET REQUIREMENTS SET FORTH IN THE SPECIFICATION MANUAL. OTHERWISE, UTILIZE FITTINGS TO MATCH CURVATURE, AS REQUIRED.
4. CHAPTER 553 - 851 OF THE FLORIDA STATUTES REQUIRES THAT AN EXCAVATOR NOTIFY GAS UTILITIES A MINIMUM OF TWO (2) WORKING DAYS PRIOR TO EXCAVATING. THE DRAWINGS SHOW ONLY THE APPROXIMATE LOCATION OF GAS MAINS AND DO NOT
SHOW SERVICE LINES.
5. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VERIFY THE HORIZONTAL & VERTICAL LOCATION OF ANY EXISTING UTILITIES OR PIPELINES PRIOR TO CONSTRUCTION. DEPTH DEPICTED IN PROFILE VIEW ARE ASSUMED TO BE THREE FEET.
6. HORIZONTAL SEPARATION BETWEEN UNDERGROUND WATER MAINS AND SANITARY OR STORM SEWERS AND WASTEWATER
FORCE MAINS.
A) NEW OR RELOCATED, UNDERGROUND WATER MAINS SHALL BE LAID TO PROVIDE A HORIZONTAL DISTANCE OF AT LEAST
THREE FEET BETWEEN THE OUTSIDE OF THE WATER MAIN AND THE OUTSIDE OF ANY EXISTING OR PROPOSED STORM
SEWER.
B) NEW OR RELOCATED, UNDERGROUND WATER MAINS SHALL BE LAID TO PROVIDE A HORIZONTAL DISTANCE OF AT LEAST SIX FEET AND PREFERABLY TEN FEET, BETWEEN THE OUTSIDE OF THE WATER MAIN AND THE OUTSIDE OF ANY EXISTING OR PROPOSED GRAVITY-TYPE SANITARY SEWER, WASTEWATER FORCE MAIN AND RECLAIMED WATER MAIN. THE MINIMUM HORIZONTAL SEPARATION DISTANCE BETWEEN WATER MAINS AND GRAVITY-TYPE SANITARY SEWERS SHALL BE REDUCED TO THREE FEET WHERE THE BOTTOM OF THE WATER MAIN IS LAID AT LEAST SIX INCHES ABOVE THE TOP OF THE SEWER.
7. VERTICAL SEPARATION BETWEEN UNDERGROUND WATER MAINS AND SANITARY OR STORM SEWERS AND WASTEWATER FORCE
MAINS.
A) NEW OR RELOCATED, UNDERGROUND WATER MAINS CROSSING ANY EXISTING OR PROPOSED GRAVITY-TYPE SANITARY
SEWER OR STORM SEWER SHALL BE A MINIMUM OF ONE FULL LENGTH OF PIPE (20'), BE CENTERED AT THE CROSSING AND LAID SO THE OUTSIDE OF THE WATER MAIN IS AT LEAST SIX INCHES, AND PREFERABLY TWELVE INCHES, ABOVE OR AT LEAST TWELVE INCHES BELOW THE OUTSIDE OF THE OTHER PIPELINE. HOWEVER, IT IS PREFERABLE TO LAY THE WATER MAIN
ABOVE THE OTHER PIPELINE.
B) NEW OR RELOCATED, UNDERGROUND WATER MAINS CROSSING ANY EXISTING OR PROPOSED WASTEWATER OR STORMWATER FORCE MAIN SHALL BE A MINIMUM OF ONE FULL LENGTH OF PIPE (20'), BE CENTERED AT THE CROSSING AND LAID TO THE OUTSIDE OF THE WATER MAIN AT LEAST TWELVE INCHES ABOVE OR BELOW THE OUTSIDE OF THE OTHER PIPELINE. HOWEVER, IT IS PREFERABLE TO LAY THE WATER MAIN ABOVE THE OTHER PIPELINE.
C) AT THE UTILITY CROSSINGS DESCRIBED IN PARAGRAPHS (A) AND (B) ABOVE, ONE FULL LENGTH OF WATER MAIN PIPE SHALL BE CENTERED ABOVE OR BELOW THE OTHER PIPELINE SO THE WATER MAIN JOINTS WILL BE AS FAR AS POSSIBLE FROM THE OTHER PIPELINE. ALTERNATIVELY, AT SUCH CROSSINGS, THE PIPES SHALL BE ARRANGED SO THAT ALL WATER MAIN JOINTS ARE AT LEAST THREE FEET FROM ALL JOINTS IN STORM SEWERS AND AT LEAST SIX FEET FORM ALL JOINTS IN GRAVITY-TYPE
SANITARY SEWERS AND WASTEWATER FORCE MAINS.
8. CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING OTHER UTILITY COMPANIES AND ARRANGING TO HAVE UTILITY POLES HELD OR RELOCATED IF DETERMINED NECESSARY FOR CONSTRUCTION. CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL COSTS
WHETHER OR NOT HOLDING UTILITY POLES IS DEPICTED IN THE PROJECT DRAWINGS.
9. FLORIDA LAW (F.S. 553.851) REQUIRES THAT PERSONS MAKING EXCAVATIONS IN PUBLIC AND PRIVATE STREETS, ALLEYS, RIGHT-OF-WAYS OR UTILITY EASEMENTS MUST FIRST OBTAIN INFORMATION ON LOCATION OF UNDERGROUND GAS PIPELINES.
10. LOCATIONS AND ELEVATIONS OF EXISTING UTILITIES EXPOSED DURING CONSTRUCTION SHALL BE ACCURATELY RECORDED ON THE CONSTRUCTION DRAWINGS. THE ENGINEER SHALL BE IMMEDIATELY NOTIFIED OF ANY CONFLICTS WITH PROPOSED CONSTRUCTION. THE ENGINEER AND/OR OWNER MAY WITHHOLD PROGRESS PAYMENTS IF AS-BUILT DRAWINGS ARE NOT MAINTAINED DURING CONSTRUCTION AND KEPT UP TO DATE WITH NEW AND EXISTING UTILITIES ACCURATELY RECORDED.
11. CONTRACTOR SHALL COORDINATE WITH ALL UTILITIES (EXISTING AND PROPOSED) TO VERIFY FINAL LOCATIONS, DEPTHS, QUANTITIES AND SIZE OF ALL UTILITIES PRIOR TO THE START OF CONSTRUCTION FOR THIS PROJECT.
12. THE INFORMATION SHOWN ON THESE DRAWINGS CONCERNING TYPE AND LOCATION OF UNDERGROUND AND OTHER UTILITIES IS BASED ON AVAILABLE RECORDS AND SURVEYS BUT IS NOT GUARANTEED TO BE ACCURATE OR ALL INCLUSIVE. THE CONTRACTOR SHALL MAKE HIS OWN DETERMINATION AS TO THE TYPE AND LOCATION OF UTILITIES AS MAY BE NECESSARY TO AVOID DAMAGE THERETO AND IS RESPONSIBLE FOR COORDINATING UTILITY RELOCATION WITH PROJECT CONSTRUCTION. CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL COSTS AND FEES ASSOCIATED WITH UTILITY RELOCATION AND/OR DAMAGE INCURRED DURING CONSTRUCTION WHETHER OR NOT THE UTILITY IS DEPICTED IN THE PROJECT DRAWINGS. CONTRACTOR WILL NOT BE COMPENSATED FOR ANY COSTS ASSOCIATED WITH LOST PRODUCTION DUE TO EXISTING UTILITIES WHETHER OR NOT THE
UTILITY IS DEPICTED IN THE PROJECT DRAWINGS.
13. IF FIELD CONDITIONS REQUIRE, THE LOCATION OF PROPOSED MAINS CAN BE ADJUSTED WITHIN THE RIGHT OF WAY WITH THE APPROVAL OF THE ENGINEER AND OWNER. THE DISTANCE FROM THE OUTSIDE EDGE OF THE MAIN AND THE RIGHT OF WAY SHALL
BE GREATER THAN OR EQUAL TO 4 FEET.
14. CONTRACTOR SHALL RESTRAIN ALL EXISTING UTILITIES AS NEEDED.
15. ALL EXISTING UTILITIES SHALL MAINTAIN SERVICE THROUGHOUT CONSTRUCTION. TEMPORARY SERVICE MAY BE REQUIRED, AT
THE EXPENSE OF THE CONTRACTOR.
16. ALL EXISTING WATER SERVICE DAMAGE OR REMOVED DURING CONSTRUCTION SHALL BE REPLACED IN THEIR ENTIRETY FROM
THE MAIN TO THE WATER METER.
17. ANY WATER MAIN WHICH REQUIRES MODIFICATIONS SHALL REQUIRE CHLORINATION AND TWO (2) CONSECUTIVE PASSING
BACTERIOLOGICAL TEST PER NSBU STANDARDS.
UTILITY PROVIDERS
WATER AND WASTEWATER
NEW SMYRNA BEACH UTILITIES
LYNN MURRISON, P.E.
LMURRISON@NSBUFL.COM
24-HOUR EMERGENCY (386) 424-1368
ELECTRIC
NEW SMYRNA BEACH UTILITIES
(386) 424-1361
24-HOUR EMERGENCY (386) 424-1366
GAS
FLORIDA PUBLIC UTILITIES
JOHNNY HILL
OFFICE (386) 668-9842
CELL (386) 747-6862
JHILL@FPUC.COM
DAVID JOHNSON
450 SOUTH HWY 17-92
DEBARY 32713
OFFICE (386) 668-9364
CELL (386) 624-4593
DJOHNSON@FPUC.COM
TELEPHONE
AT&T CONSTRUCTION AND ENGINEERING
KIRBY SPENCER
CELL (386) 366-4588
KS2488@ATT.COM
CABLE TV
BRIGHT HOUSE NETWORKS
PAUL LAIKOS
(407) 215-8838
PAUL.E.LAIKOS@CHARTER.COM
FIBER
CENTURYLINK
MARLON BROWN
(407) 374-0473
MARLON.N.BROWN@LUMEN.COM
VOLUSIA COUNTY
VOLUSIA COUNTY ENGINEERING
(386) 736-5926
Checked By:
Drawn By:
Project No.:
Designed By:
w w w .te tra te ch .c om
M
AR
K D
AT
E
D
ES
C R
IP
TI
O N
BY
8/
/2
:2 1:
A
M
C :\U
SE
R
S\
TY
LE
R
.Y O
U N
G 1\
D C
\A C
C D
O C
S\
TE
TR
A
TE
C
H
IN
C \2
-4
-2
C
O R
BI
N
P
AR
K\ W
O R
KI
N
G F
IL
ES
\C
AD
\S H
EE
TF
IL
ES
\G -0
G
EN
ER
AL
N
O
TE
S.
D
W G
YO
U N
G , T
YL
ER
A
B
C
D
E
F
2 3 4 5 6 7
Bar Measures 1 inch
C op yr ig ht : T et ra
T ec h
200-41704-22002
C O
R
BI
N P
AR
K
ST
O
R M
W
AT
ER
M
AN
AG
EM
EN
T
IM
PR
O
VE
M
EN
TS
CI
TY
O F
NE
W
S M
YR
NA
B
EA
CH
EA
ST
P
IN
E
ST
R
EE
T, S
U
IT
E
O
R
LA
N D
O , F
L
PH
O
N E:
.8
.3
F
AX
: 4
.8
.3
M ic ha el
D . T ha tc he r, P.
E.
P.
E.
N o.
, F
L
Ea st
P in e St re et
, S ui te
O rla nd o, F lo rid a
En gi ne er in g Bu si ne ss N o.
D
AT
E
PIPE MATERIAL SCHEDULE
TYPE DRAWING ABBREVIATION PIPE FITTINGS
STORM DRAIN SD SEE SPEC SECTION 02590 N/A
FORCE MAIN FM C900 DR-18 PVC DIP*
WATER MAIN WM C900 DR-18 PVC DIP*
* ALL FITTINGS SHALL BE FUSION BONDED EPOXY COATED MEETING ANSI/AWWA C116/A21.16.
G-002
G
EN
ER
AL
N O
TE
S
JW
ARM
MDT
GENERAL NOTES
48 HOURS BEFORE DIGGING
1-800-432-4770
SUNSHINE STATE ONE CALL CENTER
CALL 811
TOLL FREE
OR
Checked By:
Drawn By:
Project No.:
Designed By:
w w w .te tra te ch .c om
M
AR
K D
AT
E
D
ES
C R
IP
TI
O N
BY
8/
/2
:2 1:
A
M
C :\U
SE
R
S\
TY
LE
R
.Y O
U N
G 1\
D C
\A C
C D
O C
S\
TE
TR
A
TE
C
H
IN
C \2
-4
-2
C
O R
BI
N
P
AR
K\ W
O R
KI
N
G F
IL
ES
\C
AD
\S H
EE
TF
IL
ES
\G -0
G
EN
ER
AL
N
O
TE
S.
D
W G
YO
U N
G , T
YL
ER
A
B
C
D
E
F
2 3 4 5 6 7
Bar Measures 1 inch
C op yr ig ht : T et ra
T ec h
200-41704-22002
C O
R
BI
N P
AR
K
ST
O
R M
W
AT
ER
M
AN
AG
EM
EN
T
IM
PR
O
VE
M
EN
TS
CI
TY
O F
NE
W
S M
YR
NA
B
EA
CH
EA
ST
P
IN
E
ST
R
EE
T, S
U
IT
E
O
R
LA
N D
O , F
L
PH
O
N E:
.8
.3
F
AX
: 4
.8
.3
M ic ha el
D . T ha tc he r, P.
E.
P.
E.
N o.
, F
L
Ea st
P in e St re et
, S ui te
O rla nd o, F lo rid a
En gi ne er in g Bu si ne ss N o.
D
AT
E
VOLUSIA COUNTY RIGHT OF WAY NOTES
1. **CALL VOLUSIA COUNTY ENG. OFFICE AT (386) 736-5926, ONE BUSINESS DAY PRIOR TO BEGINNING
ALL PERMITTED WORK, ALL INSPECTIONS, ANY CHANGES FROM APPROVED PLANS AND WHEN
COMPLETED. **
*DIRECTIONAL BORES (PARALLEL & UNDER ROADS), ROAD CUTS & PAVING OPERATIONS SHALL NOT BE PERFORMED WITHIN THE RIGHT OF WAY ON FRIDAY, SATURDAY, SUNDAY, OR ANY DAY PRIOR TO A
HOLIDAY WITHOUT WRITTEN CDE/INSPECTOR APPROVAL.
2. VOLUSIA COUNTY TRAFFIC ENGINEERING (386) 736-5968 IS NOT A MEMBER OF SUNSHINE ONE CALL.
WHEN REQUESTING LOCATES, PLEASE PROVIDE A MINIMUM ADVANCED NOTIFICATION OF TWO (2)
BUSINESS DAYS PRIOR TO PROPOSED WORK.
3. ALL ROAD CLOSURES/LANE CLOSURES/LANE SHIFTS/SIDEWALK CLOSURES (& FLAGGING OPS) “ARE
SEPARATE FROM THE USE PERMIT” AND REQUIRE MOT PLAN REVIEW & APPROVAL WITH 7 DAYS
ADVANCE NOTICE TO VOLUSIA COUNTY DEVELOPMENT ENGINEERING JIM PRICE AT (386) 561-8666 OR
JPRICE@VOLUSIA.ORG PRIOR TO ANY CLOSURES. MOT IS REQUIRED ON ALL JOBS.
4. THE VOLUSIA COUNTY (STAMPED) APPROVED PLANS & PERMIT PLACARD MUST BE ONSITE AT ALL
TIMES.
5. NO STAGING/UNLOADING/PARKING OF ANY VEHICLE(S) IS ALLOWED IN THE RIGHT OF WAY OR ON SIDEWALKS. ANY DAMAGE TO THE RIGHT OF WAY WILL BE REGRADED/SODDED AND SIDEWALKS TO BE REPAIRED/REPLACED WITH 6 INCHES OF CONCRETE BY THE CONTRACTOR, PER ADA STANDARDS.
6. NO TRENCH/EXCAVATIONS SHALL BE LEFT OPEN OR UNATTENDED OVERNIGHT WITHIN THE RIGHT OF
WAY.
7. SOD ALL DISTURBED AREAS.
8. THE ENGINEER &/OR INSPECTOR'S INSPECTION, UPON CHECKING, OR ACCEPTANCE OF THE
APPLICANTS/CONTRACTOR'S “WORK”, DOES NOT RELIEVE THE CONTRACTOR OF HIS RESPONSIBILITY TO ACHIEVE THE WORK SUCH AS BUT NOT LIMITED TO- SURVEY, LINES, GRADES, DIMENSIONS &
RESTORATION WORK SHOWN IN THE PLANS OR CONTRACT DOCUMENTS PER THE USE PERMIT
PLACARD.
9. APPLICANT/CONTRACTOR IS RESPONSIBLE FOR SURVEY ACCURACY OF ALL WORK PERFORMED &
STRUCTURES TO BE PLACED WITHIN THE VOLUSIA COUNTY RIGHT OF WAYS.
10. APPLICANT/CONTRACTOR IS RESPONSIBLE FOR PRE/POST CONSTRUCTION VIDEO/PHOTOS OF
EXISTING WORK SITE.
DIRECTIONAL DRILL NOTES
1. *-DIRECTIONAL BORE OPERATIONS SHALL NOT BE PERFORMED WITHIN THE RIGHT OF WAY ON FRIDAY, SATURDAY, SUNDAY, OR ANY DAY PRIOR TO A HOLIDAY WITHOUT WRITTEN CDE/INSPECTOR
APPROVAL.
2. *ONLY DIRECTIONAL BORES METHODS CAN AND MUST BE PERFORMED.*
3. *PNEUMATIC, PUSH-PULL, MOLE OR MISSILE BORES ARE NOT PERMITTED.
4. DIRECTIONAL BORES, UNDER ROADWAYS FROM 1-3 INCHES MUST BE A MINIMUM OF 36 INCHES BELOW EDGE OF PAVEMENT. -DIRECTIONAL BORES 4 INCHES OR GREATER MUST BE 10 TIMES THE DIAMETER OF THE BORE/BACK REAMER, WHICHEVER IS GREATER, BELOW EDGE OF PAVEMENT AND
TO EXTEND TO THE RIGHT OF WAY ON EITHER SIDE.
5. ALL DIRECTIONAL DRILL MUD/SLURRY MUST BE CLEANED/RECLAIMED FROM THE RIGHT OF WAY/BORE
PITS AND DISPOSED OF ON AN APPROVED PRIVATE OFFSITE/OFF RIGHT OF WAY LOCATION.
6. *ALL DIRECTIONAL BORES OR JACK AND BORE PIT EXCAVATIONS/BOTTOM ELEVATIONS, MUST BE A
MINIMUM DISTANCE OF 2:1 FROM THE EDGE OF PAVEMENT.
7. EXCAVATIONS ARE PROHIBITED WITHIN 6 FEET FROM THE EDGE OF PAVEMENT.
PAVING NOTES
1. ALL ASPHALT MIX DESIGNS MUST BE PRE-APPROVED BY VOLUSIA COUNTY BEFORE PLACEMENT.
2. STRUCTURAL SECTION OF EXISTING PAVEMENT, BASE, STABILIZATION PAVED SHOULDER FIELD
VERIFIED PRIOR TO SAW CUTTING EDGE OF PAVEMENT.
3. SAW CUT EXISTING EDGE OF PAVEMENT FOR ALL NEW PROPOSED ROADWAY CONNECTION TIE-INS
MUST BE PERFORMED.
4. PLEASE SHOW THE EXISTING CROWN OF ROAD AND THE NEW PROPOSED CROWN OF ROAD BOTH
SHOWN ON A COMPLETE ROADWAY RIGHT OF WAY PROFILE PLAN PAGE. IDENTIFY ALSO IF
OVERBUILD OR LEVELING WILL BE NEEDED TO ACHIEVE A NEW CROWN OF ROAD.
5. *-PAVING OPERATIONS SHALL NOT BE PERFORMED WITHIN THE RIGHT OF WAY ON FRIDAY, SATURDAY, SUNDAY, OR ANY DAY PRIOR TO A HOLIDAY WITHOUT WRITTEN CDE/INSPECTOR APPROVAL.
6. FRICTION COURSE= 1.25 INCH OF FC-9.5 TL-C ASPHALT @ MAX. 20% RECYCLED MATERIALS.
7. STRUCTURAL COURSE= 2 INCH OF SP-12.5 TL-C/TL-D ASPHALT @ MAX. 30% RECYCLED MATERIALS.
8. PLEASE ALSO SHOW ON THE PLAN AND PROFILE, THE PROPOSED CROSS SLOPES PERCENTAGE W/
DIRECTIONAL ARROWS.= 10'' CRUSHED CONCRETE FINES OR LIMEROCK, COMPACTED TO A 98%
MAXIMUM DRY DENSITY PER AASHTO T-180 AND CONSTRUCTED IN ONE LIFT. =12'' STABILIZED SUB-GRADE TO A 75 FBV/LBR 40 AND COMPACTED TO A 98% MAXIMUM DRY DENSITY PER AASHTO T-180 IN ONE LIFT, “OR” IN LIEU OF STABILIZATION, UTILIZE ½ PLAN THICKNESS OF STABILIZATION W/SAME BASE MATERIALS USED, "BASE & A HALF", TO BE PLACED IN 2 LIFTS, COMPACTED TO 98% OF A T-180).
9. ALL PAVED SHOULDERS SHALL BE EQUAL IN DEPTH TO MATCH THE NEW/EXISTING ROADWAYS
STABILIZATION, BASE AND ASPHALT OVERALL THICKNESS.
10. NEW PAVING MUST MAINTAIN ADA 2% MAXIMUM SLOPES AT ALL STREET INTERSECTION CROSSWALKS.
MILL & RESURFACE NOTES
1. PLEASE NOTE/SHOW ON PLANS TO: -MILL 1-1/4'' INCH AND RESURFACE WITH 1-1/4'' INCH APPROVED
FC-9.5 TL-C ASPHALT @ MAX. 20% RECYCLE ASPHALT MIX.
2. ASPHALT RESURFACING/OVERLAYS ON ROADS MUST HAVE PROPER VISIBLE BASE/ASPHALT
STRUCTURAL CHARACTERISTICS AND MUST BE A MINIMUM OF 1.25'' IN DEPTH WITH BUTT JOINTS AT EITHER END OF THE OVERLAY ZONE AT A MINIMUM OF 10' IN WIDTH ACROSS THE LANES/SHOULDERS
TO BE OVERLAYED. (EXISTING ROADS TO BE OVERLAYED MUST BE UNCURBED ROADS, NOT TO
AFFECT EXISTING DRIVEWAYS OR DRAINAGE.)
SECTION REFERENCE
X
X-XX
REFERENCE SYMBOLSLIST OF STANDARD ABBREVIATIONS
MECHANICAL/DRAFTING LEGEND
DENOTES SECTION
LETTER IDENTIFICATION
DENOTES DRAWING NO
WHERE SECTION IS LOCATED
DETAIL REFERENCE
X
X-XX
DENOTES DRAWING NO
WHERE DETAIL IS LOCATED
DENOTES DETAIL NUMBER
IDENTIFICATION
SECTION TITLE DETAIL TITLE
SECTIONX
_ SCALE:
DETAILX
_ SCALE:
DENOTES DRAWING NO
WHERE SECTION IS LOCATED
DENOTES SECTION
LETTER IDENTIFICATION
DENOTES DRAWING NO
WHERE DETAIL IS LOCATED
DENOTES DETAIL NUMBER
IDENTIFICATION
PHANTOM LINE
HIDDEN LINE
VISIBLE LINE
CENTER LINE
BREAK LINE
EXISTING PROPOSED
MATCHLINE
1 3/32"
NOTE
CIVIL LEGEND
EXISTING STORM DRAIN
EXISTING SANITARY SEWER
EXISTING WATER MAIN
o o o o o o o o o o o o o o o o o o o GUARD RAIL xx xx xx xx STEEL FENCE x x x x x WOOD FENCE
EMBANKMENT
TOP
BOTTOM
MONITORING WELL
HYDRANT
POWER POLE
UTILITY POLE
PROPOSED MANHOLE
SEWER VALVE
EXISTING MANHOLE
MONUMENT
MITERED END SECTION
STORM MANHOLE
WATER METER
WATER VALVE
WATER WELL
MW-X
FH
CO
SS
SV
SD
WM
WV
WELL
LIGHT POLE
SEWER CLEANOUT
STORM CULVERT END
SPOT ELEVATION
XXXX.XX
EASEMENT
PROPERTY LINE
RIGHT OF WAY LINE (R-O-W)
LIMITS OF CONTRUCTION
PROPOSED CONTOUR MAJOR130
129 PROPOSED CONTOUR MINOR
(LABEL OPTIONAL)
EXISTING FORCE MAIN
VEGETATION
A
AAP ALARM ANNUNCIATOR PANEL
AARV AUTOMATIC AIR RELEASE
VALVE
AAV AUTOMATIC AIR VENT
AB ANCHOR BOLT
ABAN ABANDON(ED)
ABRSV ABRASIVE
ABS ACRYLONITRILE BUTADIENE
STYRENE
ABV ABOVE
AC ALTERNATING CURRENT
ACCMP ASPHALT-COATED
CORRUGATED METAL PIPE
ACP ASBESTOS CEMENT PIPE
ADDM ADDENDUM
ADH ADHESIVE
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AHD AHEAD
AL ALUMINUM
ALT ALTERNATE
AMP AMPERE
AMT AMOUNT
APPROX APPROXIMATE(LY)
ARCH ARCHITECT(URAL)
AS AMMONIUM SULFATE
ASPH ASPHALT
ASSY ASSEMBLY
AVE AVENUE
A/C AIR CONDITIONING
A/VV AIR/VACUUM AIR VALVE
B
BAF BAFFLE
BCV BALL CHECK VALVE
BF BLIND FLANGE
BFV BUTTERFLY VALVE
BHP BRAKE HORSEPOWER
BI BLACK IRON
BITUM BITUMINOUS OR BITUMASTIC
B/L BASELINE
BLDG BUILDING
BLK BLOCK
BM BENCH MARK
BOC BACK OF CURB
BOT BOTTOM
BP BASE PLATE
BRG BEARING
BSP BLACK STEEL PIPE
BV BALL VALVE
BW BOTH WAYS
BWW BACKWASH WATER
C
CAP CAPACITY
CA COMPRESSED AIR
CAV COMBINATION AIR VALVE
CB CATCH BASIN
CCC CHLORINE CONTACT CHAMBER
CE CHLORINATED EFFLUENT
CFM CUBIC FEET PER MINUTE
CFS CUBIC FEET PER SECOND
CV CHECK VALVE
CI CAST IRON
CIP CAST IRON PIPE
CISP CAST IRON SOIL PIPE
CJ CONSTRUCTION JOINT
CKT CIRCUIT
C/L CENTER LINE
CL2 SODIUM HYPOCHLORITE
CLF CHAIN LINK FENCE
CLR CLEAR OR CLEARANCE
CLVT CULVERT
CMP CORRUGATED METAL PIPE
CMPA CORRUGATED METAL PIPE
ARCH
CMU CONCRETE MASONRY UNIT
CND CONDUIT
CNR CORNER
CO CLEAN OUT
CO2 CARBON DIOXIDE
COAG COAGULANT
COL COLUMN
COM COMMON
CONC CONCRETE
CONN CONNECTION
CONSTR CONSTRUCT(ION)
CONT CONTINUOUS
CONTR CONTRACT(OR)
COORD COORDINATE
CO COMPANY
CP CONCRETE PIPE
CPA CONCRETE PIPE ARCH
CPLG COUPLING
CPVC CHLORINATED POLYVINYL
CHLORIDE
CR CONCENTRIC REDUCER
CS CHLORINE SOLUTION
CSG CASING
CTV CABLE TELEVISION
CY CUBIC YARD
CYL CYLINDER
C&G CURB AND GUTTER
C/C CENTER TO CENTER
D
DAT DATUM
DBL DOUBLE
DC DIRECT CURRENT
DEMO DEMOLITION
DEPT DEPARTMENT
DESC DESCRIPTION
DET DETAIL
DF DIESEL FUEL
DI DUCTILE IRON
DIA DIAMETER
DIFF DIFFUSER
DIM DIMENSION
DIP DUCTILE IRON PIPE
DISCH DISCHARGE
DIR DIRECTION
DMH DROP MANHOLE
DN DOWN
DR DRAIN
DV DIAPHRAGM VALVE
DW DRIVEWAY
DWG DRAWING
DWV DRAIN, WASTE, AND VENT
E
E EAST
EA EACH
ECC ECCENTRIC
EF EACH FACE
EFF EFFLUENT
E/L EASEMENT LINE
EL ELEVATION
ELAST ELASTOMERIC
ELEC ELECTRICAL
EMER EMERGENCY
EMC ENCASE(MENT)
ENGR ENGINEER
EP EDGE OF PAVEMENT
EPDM ETHYLENE PROPYLENE DIENE
MONOMER
EPRF EXPLOSION PROOF
EQUIP EQUIPMENT
ER ECCENTRIC REDUCER
ESTM EASEMENT
EST ESTIMATE(D)
EW EACH WAY
EX EXISTING
EXC EXCAVATE
EXP EXPANSION
EXST EXISTING
EXST GR EXISTING GRADE
EXT EXTERIOR
EXTN EXTENSION
F
FAB FABRICATE(D)
FCA FLANGED COUPLING ADAPTER
FB FLAT BAR
FCV FLOW-CONTROL VALVE
FD FLOOR DRAIN
FDN FOUNDATION
FE FILTER(ED) EFFLUENT
FHY FIRE HYDRANT
FIG FIGURE
FIN FINISH(ED)
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FL FLUORIDE
FLG FLANGE(D)
FLL FLOW LINE
FLTR FILTER
FM FORCE MAIN
FPM FEET PER MINUTE
FPS FEET PER SECOND
FRP FIBERGLASS REINFORCED
PLASTIC
FT FOOT OR FEET
FUT FUTURE
FV FOOT VALVE
FW FINISHED WATER
FWP FACTORY WIRED PANEL
F/F FACE TO FACE
G
GA GAUGE
GAL GALLON(S)
GALV GALVANIZED
GIP GALVANIZED IRON PIPE
GJ GROOVE JOINT
GND GROUND
GPD GALLONS PER DAY
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GPS GALLONS PER SECOND
GR GRADE
GRTG GRATING
GS GALVANIZED STEEL
GSP GALVANIZED STEEL PIPE
GSR GROUND STORAGE RESERVOIR
GST GROUND STORAGE TANK
GT GROUT
GV GAS VALVE
H
HB HOSE BIBB
HD HEAVY-DUTY
HDPE HIGH-DENSITY POLYETHYLENE
HDR HYDRAULIC
HFA HYDROFLUOSILICIC ACID
HGR HANGER
HGT HEIGHT
HNDRL HAND RAIL
HOA HAND-OFF-AUTO
HORIZ HORIZONTAL
HP HORSEPOWER
HPA HIGH PRESSURE AIR
HR HOUR
HVAC HEATING, VENTILATION, AND AIR
CONDITIONING
HWL HIGH WATER LEVEL
HWY HIGHWAY
HZ HERTZ
I
ID INSIDE DIAMETER
IN INCH(ES)
INF INFLUENT
INT INTERSECTION
INTR INTERIOR
IE INVERT ELEVATION
IP IRON PIPE
IPS INTERNATIONAL PIPE
STANDARD
IR INTERNAL RECYCLE
IW IRRIGATION WATER
J
JB JUNCTION BOX
JT JOINT
K
K KIP (1,000 LB)
KPL KICK PLATE
KV KILOVOLT
KVA KILOVOLT-AMPERE
KW KILOWATT
KWH KILOWATT-HOUR
L
L LEFT
LAB LABORATORY
LAM LAMINATE OR LAMINATION
LATL LATERAL
LAV LAVATORY
LEN LENGTH
LB POUND(S)
LF LINEAR FEET
LP LIGHT POLE
LS LIME SLURRY
LSS LIME STABILIZED SLUDGE
LVR LOUVER
LWL LOW WATER LEVEL
M
M METER
MAINT MAINTAIN OR MAINTENANCE
MAN MANUAL(LY)
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MCC MOTOR CONTROL CENTER
ME MITERED END
MECH MECHANICAL
MEG MATCH EXISTING GRADE
MFR MANUFACTURE(R)
MG MILLION GALLONS
MGD MILLION GALLONS PER DAY
MH MANHOLE
MI MILE(S)
MIN MINIMUM, MINUTE(S)
MISC MISCELLANEOUS
MJ MECHANICAL JOINT
ML MIXED LIQUOR
MO MASONRY OPENING
MON MONUMENT
MPH MILES PER HOUR
MPT MALE PIPE THREAD
MS MOTOR STARTER
MSP MOTOR STARTER PANEL
MTD MOUNTED
MV MOTORIZED VALVE
MW MANWAY
MWL MEAN WATER LEVEL
MWP MAXIMUM WORKING PRESSURE
N
N NORTH
NH3 AMMONIUM SULFATE
NE NORTHEAST
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NPF NATIONAL PIPE THREAD
NPT NATIONAL PIPE TAPER
(THREAD)
NPW NON-POTABLE WATER
NRS NON-RISING SYSTEM
NSB NEW SMYRNA BEACH
NSBU NEW SMYRNA BEACH UTILITIES
NTS NOT TO SCALE
NW NORTHWEST
N/A NOT APPLICABLE
O
O2 OXYGEN
OC ON CENTER
OCL SODIUM HYPOCHLORITE
OD OUTSIDE DIAMETER
ODP OPEN DRIP PROOF
OF OVERFLOW
OH OVER HEAD
OHW OVER HEAD WIRE
OPP OPPOSITE
OPT OPTIONAL
OR OFFICIAL RECORDS
OSY OUTSIDE SCREW AND YOKE
O&M OPERATION AND MAINTENANCE
P
PA PROCESS AIR
PC POINT OF CURVE
PCM PERMANENT CONTROL
MONUMENT
PE PLAIN END
PG PRESSURE GAGE
PI POINT OF INTERSECTION
PL PLATE
P/L PROPERTY LINE
PNV PINCH VALVE
PO4 CORROSION INHIBITOR
POB POINT OF BEGINNING
POE POINT OF ENTRY
POJ PUSH-ON JOINT
POL POLYMER
PP POWER POLE
PPD POUNDS PER DAY
PPM PARTS PER MILLION
PREFAB PREFABRICATED
PRESS PRESSURE
PRV PRESSURE REDUCING VALVE
PRW PROCESS WATER
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PSIA POUNDS PER SQUARE INCH
ABSOLUTE
PSIG POUNDS PER SQUARE INCH
GAGE
PT POINT OF TANGENCY
PV PLUG VALVE
PVC POLYVINYL CHLORIDE
PVMT PAVEMENT
PW POTABLE WATER
PWR POWER
Q
Q FLOW
QTY QUANTITY
R
RAD RADIUS
RAS RETURN ACTIVATED SLUDGE
RC REINFORCED CONCRETE
RCB REINFORCED CONCRETE BOX
RCP REINFORCED CONCRETE PIPE
RCPA REINFORCED CONCRETE PIPE
ARCH
RD ROAD
RDCR REDUCER
REBAR REINFORCING STEEL
REF REFERENCE
REINF REINFORCE(D)(ING)(MENT)
REM REMOVE(ABLE)
REQ'D REQUIRED
RF RAISED FACE
RJ RESTRAINED JOINT
RM ROOM
RPBP REDUCED PRESSURE
BACKFLOW PREVENTER
RPM REVOLUTIONS PER MINUTE
RR RAILROAD
RT RIGHT
RVT RIVETED
RWM RAW WATER
RWW RAW WASTEWATER
R/W RIGHT-OF-WAY
S
S SOUTH
SA SAMPLE LINE
SAN SANITARY
SCHED SCHEDULE
SD STORM DRAIN
SE SOUTHEAST
SECT SECTION
SEFF SECONDARY EFFLUENT
SF SQUARE FOOT OR FEET
SHT SHEET(ED)(ING)
SIG SIGNAL
SIM SIMILAR
SL SLUDGE
SLV SLEEVE
SM SHEET METAL
SOLN SOLUTION
SP SOIL PIPE, SPACE(ING)
SPEC SPECIFICATION
SPRT SUPPORT
SQ SQUARE
SS SANITARY SEWER
SSE SUBSTANDARD EFFLUENT
SST STAINLESS STEEL
ST STREET
STA STATION
STD STANDARD
STK STAKE
STL STEEL
STR STRAIGHT
STRUCT STRUCTURAL
SURF SURFACE
SV SOLENOID VALVE
SVCE SERVICE
SVW SERVICE WATER
SW SOUTHWEST
SWD SIDEWATER DEPTH
SWSH SURFACE WASH
SYM SYMBOL
SYMM SYMMETRICAL
S/W SIDEWALK
T
TAN TANGENT
TB TOP OF BEAM
TBM TEMPORARY BENCH MARK
TB-xx TEST BORING-xx (e.g. TB-1)
TD TRENCH DRAIN
TDH TOTAL DYNAMIC HEAD
TE TOTALLY ENCLOSED
TEFC TOTALLY ENCLOSED FAN
COOLED
TEL TELEPHONE
TENV TOTALLY ENCLOSED
NON-VENTILATED
THD THREAD(ED)
THK THICK(NESS)
TLM TELEMETRY
TOB TOP OF BANK
TOC TOP OF CURB
TOS TOE OF SLOPE
TOT TOTAL
TP TELEPHONE POLE
TS THICKENED SLUDGE
TV TELEVISION
TYP TYPICAL
T&B TOP AND BOTTOM
U
UD UNDERDRAIN
UG UNDERGROUND
ULT ULTIMATE
UN UNION
UON UNLESS OTHERWISE NOTED
UGE UNDERGROUND ELECTRIC
UTC UNDERGROUND TELEPHONE
CABLE
UTIL UTILITY
V
V VOLT(S)
VAC VACUUM
VAR VARIES
VC VERTICAL CURVE
VCP VITRIFIED CLAY PIPE
VEL VELOCITY
VERT VERTICAL
VFD VARIABLE FREQUENCY DRIVE
VOL VOLUME
W
W WATER MAIN
WAS WASTE ACTIVATED SLUDGE
WCO WALL CLEAN OUT
WF WIDE FLANGE
WH WALL HYDRANT
WL WATER LINE
WM WATER MAIN
WP WATER PROOF(ING), WORKING
POINT
WPR WORKING PRESSURE
WS WATER SURFACE
WSP WELDED STEEL PIPE
WT WEIGHT
WTP WATER TREATMENT PLANT
WV WATER VALVE
WW WASH WATER
WWF WELDED WIRE FABRIC
WWM WELDED WIRE MESH
WWTP WASTEWATER TREATMENT
PLANT
W/ WITH
W/O WITHOUT
X
XFER TRANSFER
Y
YD YARD(S)
YH YARD HYDRANT
YR YEAR(S) YR
FM
DRIVEWAY
RESTORATION
PROPOSED STORM DRAIN
SS
SS PROPOSED SANITARY SEWER
INLET/MANHOLE TO
BE REMOVED
PIPE TO BE GROUT
FILLED & ABANDONED
XXXXXX PIPE TO BE REMOVED
TREE PROTECTION
TREE REMOVAL
DIMENSION
LINES AND
LEADERS
SD
SD
FLARED END SECTION
DROP INLET
ASPHALT MILL AND
RESURFACE
REMOVE AND REPLACE
EXISTING PAVEMENT
CURB RESTORATION
| | | | | | | | | | | | CURB TO BE REMOVED
SHELL ROAD REMOVE
AND REPLACE
W PROPOSED WATER MAIN
W
FM PROPOSED FORCE MAIN
MECHANICAL/DRAFTING LEGEND
G-003
LE
G
EN
D
S
AB
BR
EV
IA
TI
O
N S
JW
ARM
MDTChecked By:
Drawn By:
Project No.:
Designed By:
w w w .te tra te ch .c om
M
AR
K D
AT
E
D
ES
C R
IP
TI
O N
BY
8/
/2
:2 1:
A
M
C :\U
SE
R
S\
TY
LE
R
.Y O
U N
G 1\
D C
\A C
C D
O C
S\
TE
TR
A
TE
C
H
IN
C \2
-4
-2
C
O R
BI
N
P
AR
K\ W
O R
KI
N
G F
IL
ES
\C
AD
\S H
EE
TF
IL
ES
\G -0
L
EG
EN
D S
AB
BR
EV
IA
TI
O N
S.
D
W G
YO
U N
G , T
YL
ER
A
B
C
D
E
F
2 3 4 5 6 7
Bar Measures 1 inch
C op yr ig ht : T et ra
T ec h
200-41704-22002
C O
R
BI
N P
AR
K
ST
O
R M
W
AT
ER
M
AN
AG
EM
EN
T
IM
PR
O
VE
M
EN
TS
CI
TY
O F
NE
W
S M
YR
NA
B
EA
CH
EA
ST
P
IN
E
ST
R
EE
T, S
U
IT
E
O
R
LA
N D
O , F
L
PH
O
N E:
.8
.3
F
AX
: 4
.8
.3
M ic ha el
D . T ha tc he r, P.
E.
P.
E.
N o.
, F
L
Ea st
P in e St re et
, S ui te
O rla nd o, F lo rid a
En gi ne er in g Bu si ne ss N o.
D
AT
E
C-101
C-101
C-102
C-103
C-104
C-104
C-105
C-105
C-106
C-106
C-107
C-107
C-108
C-108
C-109
C-109
C-111
C-110 C-103
C-102
DAVIS DR
JUANITA DR
SWOOPE DR
DOSTER DR
LIVE OAK DR
PINE ISLAND DR
PAIGE AVE
DOLORES ST
HAWKS COVE CIR
ROBIN RD
ANNETTE RD
TROPHY HUNTER TR
SIERRA DR
UNDEVELOPED ROW
CAROLYN ST
JUDY ST
S W
ALKER DR
CORBIN PARK RD
CORBIN PARK RD
HAWKS COVE CIR
BURMA RD
MAGNOLIA DR
102. BENCHMARK IR LB26
N 1696911.3620 E 672639.2670
ELEV 5.69
639. BENCHMARK ND LB26
N 1697632.5000 E 672351.8300
ELEV 5.42
4425. BENCHMARK ND LB26
N 1695541.3350
E 671696.4240
ELEV 7.22
5413. BENCHMARK ND LB26
N 1699391.7880
E 671220.1480
ELEV 7.24
12896. BENCHMARK ND LB26
N 1700076.6930
E 671677.0400
ELEV 4.40
16864. BENCHMARK ND LB26
N 1699936.8450
E 670918.1550
ELEV 6.23
16866.BENCHMARK ND LB26
N 1698652.0770
E 670870.4420
ELEV 7.46
BENCHMARK TABLE
PT#
12896
16864
16866
DESCRIPTION
BENCHMARK IR LB26
BENCHMARK ND LB26
BENCHMARK ND LB26
BENCHMARK ND LB26
BENCHMARK ND LB26
BENCHMARK ND LB26
BENCHMARK ND LB26
ELEVATION
5.69
5.42
7.22
7.24
4.40
6.23
7.46
NORTHING
1696911.3620
1697632.5000
1695541.3350
1699391.7880
1700076.6930
1699936.8450
1698652.0770
EASTING
672639.2670
672351.8300
671696.4240
671220.1480
671677.0400
670918.1550
670870.4420
Checked By:
Drawn By:
Project No.:
Designed By:
w w w .te tra te ch .c om
M
AR
K D
AT
E
D
ES
C R
IP
TI
O N
BY
8/
/2
:2 1:
A
M
C :\U
SE
R
S\
TY
LE
R
.Y O
U N
G 1\
D C
\A C
C D
O C
S\
TE
TR
A
TE
C
H
IN
C \2
-4
-2
C
O R
BI
N
P
AR
K\ W
O R
KI
N
G F
IL
ES
\C
AD
\S H
EE
TF
IL
ES
\C -1
E
XI
ST
IN
G
C O
N D
IT
IO
N S
D
EM
O
LI
TI
O N
K
EY
P
LA
N .D
W G
YO
U N
G , T
YL
ER
A
B
C
D
E
F
2 3 4 5 6 7
Bar Measures 1 inch
C op yr ig ht : T et ra
T ec h
200-41704-22002
C O
R
BI
N P
AR
K
ST
O
R M
W
AT
ER
M
AN
AG
EM
EN
T
IM
PR
O
VE
M
EN
TS
CI
TY
O F
NE
W
S M
YR
NA
B
EA
CH
EA
ST
P
IN
E
ST
R
EE
T, S
U
IT
E
O
R
LA
N D
O , F
L
PH
O
N E:
.8
.3
F
AX
: 4
.8
.3
M ic ha el
D . T ha tc he r, P.
E.
P.
E.
N o.
, F
L
Ea st
P in e St re et
, S ui te
O rla nd o, F lo rid a
En gi ne er in g Bu si ne ss N o.
D
AT
E
N
0 75' 150' 300'
C-100
EX
IS
TI
N
G C
O N
D
IT
IO
N
S
D
EM
O
LI
TI
O
N
KE
Y
PL
AN
JW
ARM
MDT
OAK (UNLESS NOTED OTHERWISE)
PINE
MAGNOLIA
PALM
EVERGREEN
CYPRESS
CEDAR
BAY
MYRTLE
TREE LEGENDTREE LEGEND
1. HORIZONTAL COORDINATES ARE BASED ON NAD83 (2011), FLORIDA EAST ZONE.
2. ELEVATIONS SHOWN HEREON ARE BASED ON NATIONAL GEODETIC SURVEY BENCHMARK #
M212, BEING A NAIL AND DISK SET IN A CONCRETE RETAINING WALL, HAVING A PUBLISHED
ELEVATION OF 6.31. (NAVD 88)
3. THERE MAY BE EASEMENTS AND RESTRICTIONS OF RECORDS AND/OR PRIVATE
AGREEMENTS NOT FURNISHED TO THIS SURVEYOR THAT MAY AFFECT PROPERTY RIGHTS
AND/OR LAND USE RIGHTS OF THE LANDS SHOWN HEREON.
4. NO UNDERGROUND INSTALLATIONS, FOUNDATION FOOTINGS OR IMPROVEMENTS HAVE BEEN
LOCATED EXCEPT AS NOTED.
5. THIS SURVEY WAS PERFORMED IN ACCORDANCE WITH THE STANDARDS OF PRACTICE FOR
SURVEYS AS SET FORTH BY THE FLORIDA BOARD OF PROFESSIONAL SURVEYORS AND
MAPPERS, CHAPTER 5J-17, FLORIDA ADMINISTRATIVE CODE.
6. BASED ON THE NATIONAL FLOOD INSURANCE PROGRAM "FIRM" MAP COMMUNITY - PANEL
NUMBER 12127 C 0540J & 12127 C 0700J DATED 09/29/2017 THE SHOWN AREA IS LOCATED IN
ZONES "X" AND "AE". ZONE "AE" HAVING AN ELEVATION OF 5.00.
7. THIS FIELD SURVEY WAS PERFORMED ON DECEMBER 5, 2022.
NOTES
S
F
P
UTILITY MARKER (AS SHOWN)
UTILITY METER (AS SHOWN)
UTILITY RISER (AS SHOWN)
UTILITY MANHOLE (AS SHOWN)
UTILITY VALVE (AS SHOWN)
LIGHT POLE
ELECTRIC TRANSFORMER
FIRE HYDRANT
SATELLITE DISH
POST
TRAFFIC SIGN
SPRINKLER HEAD
SPIGOT
WELLDECIDUOUS TREE
EVERGREEN TREE
CLEANOUT
FLAG (AS SHOWN)
BENCHMARK
NAIL & DISK
TRAVERSE POINT
SET 1/2" IRON ROD LB# 26
FOUND IRON (TYPE)
SECTION CORNER
BM
ND
TP
SC
CO UTILITY POLE (AS SHOWN)
GUY ANCHOR
MAILBOXMB
PALM TREE
F
S SET MONUMENT (TYPE)
FOUND MONUMENT (TYPE)
ANT ANTENNA
BFP BACK FLOW PREVENTER
BM BENCHMARK
(C) CALCULATED
CO CLEANOUT
CONC CONCRETE
CM CONCRETE MONUMENT
CMP CORRUGATED METAL
PIPE
CPP CORRUGATED PLASTIC
PIPE
(D) AS DESCRIBED
DIP DUCTILE IRON PIPE
DH DRILL HOLE
EB ELECTRIC RISER
ELEC ELECTRIC
EM ELECTRIC METER
EOP EDGE OF PAVEMENT
ET ELECTRIC TRANSFORMER
F FOUND
FDC FIRE DEPT CONNECTION
FF FINISHED FLOOR
FH FIRE HYDRANT
FO FIBER OPTIC
G GAS
GM GAS METER
GV GAS VALVE
INV INVERT
IP IRON PIPE
IR IRON ROD
IRRV IRRIGATION VALVE
JBL JURISDICTIONAL
BOUNDARY LINE
(M) MEASURED
MB MAILBOX
MH MANHOLE
MW MONITORING WELL
ND NAIL & DISK
NL NAIL
OE OVERHEAD UTILITY LINES
OR OFFICIAL RECORDS
P POST
(P) PER PLAT
PB PLAT BOOK
PG PAGE
PK PK NAIL
POL POINT ON LINE
RCP REINFORCED CONC PIPE
RR RAILROAD
RW RECLAIMED WATER
S SET
SC SECTION CORNER
SH SPRINKLER HEAD
SPIG WATER SPIGOT
SS SANITARY SEWER
SD STORM DRAIN
SV SANITARY SEWER VALVE
TB TELEPHONE RISER
TEL TELEPHONE
TP TRAVERSE POINT
TSC TRAFFIC SIGNAL
CONTROL
TSP TRAFFIC SIGNAL POLE
TV CABLE TELEVISION
UE UNDERGROUND UTILITY
LINES
W WATER
WM WATER METER
WV WATER VALVE
XC X CUT
LEGEND
ABBREVIATIONS
BENCHMARK
15" RCP
INV 3.16
MB MB
MB
MB
MB
MB
1143 CORBIN PARK RD
FF = 6.59
2201 JUANITA DR
FF = 8.60
1144 CORBIN PARK RD
FF = 6.85
1160 CORBIN PARK RD
FF = 7.89
1086 CORBIN PARK RD
FF = 8.04
2190 SWOOPE DR
FF = 5.81
1188 CORBIN PARK RD
FF = 8.48
RIP RAP
18" CMP INV 3.43
RIP RAP
18" CMP INV 3.34
WM
W M
2xW M
W M
WM
WMWV
FH
2xWV 2xWV
14x22" CMP
W INV 3.19
14x23" CMP
W INV 3.40
E INV 3.41
CONC
DRIVE CONC
DRIVE
CONC
DRIVE
CONC
DRIVE
C O
N C
D R
IVE
C O
N C
D R
IVE
C O
N C
D R
IVE
C O
N C
D R
IVE
ROW R
O
W
ROW
ROWROW
EOP
CURBCURB
C U
R B
CURB
DITCH CL
C O
N C
D R
IVE
CHAIN LINK FENCE
OSW N1
(GIS)
2203 JU
AN
ITA D
R
FF = 8.57
UNPAVED ROAD
CURB
EOP
DITCH CL
5.27
5.47 5.11
5.24
5.58
5.98
5.68
5.86
6.13
5.37
5.26
5.90 5.
6.34
5.88
6.45 6.70 6.44
5.24
5.40
5.50
5.10
5.32
5.32
3.8
3.9
3.1
5.1 4.7
5.1
5.1 4.9
5.1
3.4
4.8
5.4
2.5
4.6
4.7
5.3
5.4
4.7 5.8
5.3
4.9
4.8
5.3
4.7
5.0 3.7
5.1
5.2
5.6 5.8
5.6 4.6
3.7
3.5 4.7
5.0
5.4
5 4
TH #01SOIL BORING TH #20 @ 3.80'
SOIL BORING TH #21 @ 5.55' PV
2xWV
4''FM
4''FM 4''FM 4''FM 4''FM 4''FM 4''FMUT UT
UT UT UT UTUT
6''W 6''W
8''W
OE OE OE OE
O E
8''W 8''W 8''W 8''W 8''W 8''W
8''W
100+00 101+00
102+00 103+00 104+00 105+00 106+00 107+00
4+
5+
5+
.5
5+
6+
6+
.9
X X
X X
X X
X X
X X
X X
X X
X X
X
X X
X X
X X
DROP INLET
TOP 5.13
15" RCP (NE) INV 2.71
15" CPP (NW) INV 2.79
15" RCP INV 2.62
15" RCP INV 2.74
15" RCP INV 2.84
6" RETAINING WALL
18" CMP INV 3.52
6" RETAINING WALL
18" CMP INV 3.47
15" CPP INV 2.80
15" RCP INV 2.80
XXXXXXXX
XXXXXX
15" CPP INV 3.26
XXXXXX
15" CMP INV 2.82
CORBIN PARK RD
(ROW VARIES)
D
AV
IS
D
R (5
0' R
O W
JU
AN
IT
A
D R
(5 0'
R O
W
TURBIDITY BARRIER
REMOVE CURB
(TYP.)
CUT AND CAP
ABANDON EXIST WM
(GROUT FILL)
MB
MB
SV
BENCHMARK ND LB26
N 1697632.5000
E 672351.8300
ELEV 5.42
MB
MB
MB
MB
MB
FOC BOX
2200 DOSTER DR
FF = 8.13
2194 DOSTER DR
FF = 6.03
2201 DOSTER DR
FF = 8.11
2200 SIERRA DR
FF = 8.16
2195 DOSTER DR
FF = 7.96
2203 SWOOPE DR
FF = 8.17
1045 CORBIN PARK RD
FF = 6.53
WM
WM
2xWM
3xWV WV
14x22" CMP
W INV 3.19
E INV 3.20
14x23" CMP
W INV 3.40
E INV 3.41
CONC
DRIVE
C O
N C
D R
IVE
C O
N C
D R
IVE
EOP
TOB
TOB
TOB
DITCH CL
DITCH CL
VEGETATION LINE
VEGETATION LINE
CONC
DRIVE
CONC
DRIVE
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
2xWV
WV
2xWV
WM
VEGETATION LINE
CURB CURB
U N
PAVED
D
R
IVE
TOB
TOB
DITCH CL DITCH CL
WM
WM 2xWM
OSW H21
OSW H21
OSW H24
DITCH CL
CURB
CURB
EOP
4.99
5.35
5.19
5.15
5.20 5.40
5.08 5.46 5.61
5.16
5.47
5.36
6.51
6.29
6.35
5.31 5.44
5.21
5.24
5.49
5.01
5.54
5.11
5.02
5.76
6.14
5.69
4.2
4.9
3.1 4.4
4.34.8
3.0 2.9 2.5 4.4
4.8
3.5
4.7 5.6
4.6 3.2
4.9
2.6 2.5
4.4
3.0
4.9
3.2
4.6 2.4
4.0
2.3
5.5 5.8
2.1
5.7
5.2
5.9
5.5
2.3 1.8 1.6 3.7
1.7 4.1
2.0 4.7
5.8 5.4
5.8
5.3
4.7 5.6 4.7
4.8 4.7
4.2
4.3 4.0
6 6
5 5
TH #02
TH #03
TH #10
4''FM 4''FM 4''FM 4''FM
4''FM 4''FM 4''FM 4''FM
UT UT UT UT UT UT UT UT8''W 8''W 8''W 8''W
6' 'W
6''W
U T
U T
6''W 6''W
SD
18''SD
OE OE
O E
O E
OE OE
O E
O E
OE OE OE
8''W 8''W 8''W 8''W
107+00 108+00 109+00 110+00 111+00 112+00 113+00 114+00 115+00
3+
4+
4+
.3
1+
2+
2+
.5
XXXXXXXXXXXX
XXXXXXXXXXXX
MES
24" RCP INV 1.86
MES
24" RCP INV 1.80 MES
24" RCP INV 1.49
MES
24" RCP INV 1.66
14x23" ERCP INV 2.52
14x23" ERCP INV 2.58
XXXXXXX
DROP INLET
TOP 4.90
14X23" RCP (NE) INV 2.54
15" CMP (SE) INV 2.99
15" CMP INV 2.99
SW
O
O
PE
D R
(5 0'
R O
W
CORBIN PARK RD
(ROW VARIES)
SI
ER
R A
D R
(5 0'
R O
W
12" CPP INV 3.52
DROP INLET
TOP 4.70
18" CPP (NE) INV 2.36
14X23" ERCP (SW) INV 2.47
12" CPP (NW) INV 3.04
X X
X X
X X
X X
XXXXXXXX
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
D O
ST
ER
D R
(5 0'
R O
W
X X
X X
X
X REMOVE CURB
(TYP.)
CUT AND CAP,
ABANDON EXIST 6" WM
(GROUT FILL)
14x23" CMP INV 3.41
14x23" CMP INV 3.40
C-101
C O
R
BI
N P
AR
K
R O
AD
EX
IS
TI
N G
C O
N D
IT
IO
N S
D
EM
O
LI
TI
O N
P
LA
N
JW
ARM
MDTChecked By:
Drawn By:
Project No.:
Designed By:
w w w .te tra te ch .c om
M
AR
K D
AT
E
D
ES
C R
IP
TI
O N
BY
8/
/2
:2 2:
A
M
C :\U
SE
R
S\
TY
LE
R
.Y O
U N
G 1\
D C
\A C
C D
O C
S\
TE
TR
A
TE
C
H
IN
C \2
-4
-2
C
O R
BI
N
P
AR
K\ W
O R
KI
N
G F
IL
ES
\C
AD
\S H
EE
TF
IL
ES
\C -1
E
XI
ST
IN
G
C O
N D
IT
IO
N S
D
EM
O
LI
TI
O N
P
LA
N .D
W G
YO
U N
G , T
YL
ER
A
B
C
D
E
F
2 3 4 5 6 7
Bar Measures 1 inch
C op yr ig ht : T et ra
T ec h
200-41704-22002
C O
R
BI
N P
AR
K
ST
O
R M
W
AT
ER
M
AN
AG
EM
EN
T
IM
PR
O
VE
M
EN
TS
CI
TY
O F
NE
W
S M
YR
NA
B
EA
CH
EA
ST
P
IN
E
ST
R
EE
T, S
U
IT
E
O
R
LA
N D
O , F
L
PH
O
N E:
.8
.3
F
AX
: 4
.8
.3
M ic ha el
D . T ha tc he r, P.
E.
P.
E.
N o.
, F
L
Ea st
P in e St re et
, S ui te
O rla nd o, F lo rid a
En gi ne er in g Bu si ne ss N o.
D
AT
E
40'20' 80'0
N
40'20' 80'0
N
M
AT
C H
LI
N
E
- T
H
IS
S H
EE
T
MATCHLINE - SEE SHEETC-104 MATCHLINE - SEE SHEETC-105
M
AT
C H
LI
N
E
- T
H
IS
S H
EE
T
M
AT
C H
LI
N
E
- S
EE
S
H
EE
TC-
MATCHLINE - SEE SHEETC-106 MATCHLINE - SEE SHEETC-107
NOTES:
1. PIPE TO BE CUT AND CAPPED ON ANY
EXPOSED ENDS, AND REMOVED WHERE IN
CONFLICT WITH THE PROPOSED
IMPROVEMENTS. REMAINDER OF THE PIPE
SHALL BE GROUT FILLED AND ABANDONED IN
PLACE.
2. EROSION AND SEDIMENT CONTROL SHALL
CONSIST OF SILT FENCE, INLET PROTECTION,
AND TURBIDITY BARRIERS PER
SPECIFICATION SECTION 01568.
C-501
REMOVAL LEGEND
INLET/MANHOLE TO
BE REMOVED
PIPE TO BE GROUT FILLED &
ABANDONED
PIPE TO BE REMOVED
TREE PROTECTION
TREE REMOVAL
ASPHALT MILL AND
RESURFACE
REMOVE AND REPLACE
EXISTING PAVEMENT
| | | | | | | | | | | CURB TO BE REMOVED
DRIVEWAY REMOVE
AND REPLACE
SHELL ROAD REMOVE
AND REPLACE
X X X X X
C-503
C-503
C-503
C-503
MB MB
MB
MB
MB
MBMBMB
GATE
880 CORBIN PARK RD
950 CORBIN PARK RD
827 CORBIN PARK RD
840 CORBIN PARK RD860 CORBIN PARK RD
875 CORBIN PARK RD
870 CORBIN PARK RD
2201 SIERRA DR
FF = 8.24
850 CORBIN PARK RD
C O
N C
D R
IVE
C O
N C
D R
IVE
C O
N C
D R
IVE
C O
N C
D R
IVE
C O
N C
D R
IVE
C O
N C
D R
IVE
C O
N C
D R
IVE
C O
N C
D R
IVE
C O
N C
D R
IVE
12" RETAINING WALL
TOP 6.68
SB TH-3
ELEV 4.67
W M W M
WM
WM
2xWM
WM
WM
SB AB-9
ELEV 5.43
U N
PAVED
D
R
IVE
ASPH
ALT
D R
IVE
TOB
TOB
TOB
DITCH CL
DITCH CL
DITCH CL DITCH CL
D
ITC
H C
L
TOB
TO
B2xUE EB
W O
O D
FEN
C
E
CHAIN LINK FENCE
W O
O D
PO
ST FEN
C E
UTV
OSW G1
OSW G3
OSW G5
W
ETLAN
D (G
IS)
OSW H7
OSW H9
EOP
TO
B TO
S
TOB
DITCH CL
ROW
R O
W
5.02
5.70
5.44 5.40
5.05 5.28
4.83
5.22
5.53
5.61
5.56
5.75 5.96
4.3
1.8 1.3
2.2
1.2 4.7
4.9 5.3
0.1 4.3
0.8 4.8
2.8
1.0 4.6
1.2 2.0
4.8
1.5
1.4 2.2
4.1 4.6
1.94.5
5.2
5.2
5.3
5.2
22 3
1 2 3 4
3 4
3 4
2 3 4
TH #04
10" PVC
ELEV 2.68
4''FM 4''FM 4''FM 4''FM 4''FM 4''FM 4''FM 4''FM
UT UT8''W 8''W
xxxxxxxx
8''W 8''W 8''W 8''WUT UT UT UT
x
8''W
OE
OE OE OE OE OE OE OE
10''SD
115+00 116+00 117+00 118+00 119+00 120+00 121+00 122+00 123+00
XXXXXXXX X
X
X X
X X
X X
X
XXXX
XXXXXXX XXXXXX XXXXXXXXXXXXXXXXXXXXXXX
MES
24" RCP INV 1.97
MES
24" RCP INV 2.06
24" CMP INV 1.22
24" CMP INV 1.04
24" RCP INV 0.53
24" RCP INV 0.34
24" CMP INV 1.33
24" CMP INV 1.24
24" RCP INV 1.44
24" RCP INV 1.52
24" CPP INV 1.33
24" CPP INV 1.13
CORBIN PARK RD
(ROW VARIES)
U N
D
EV
EL
O
PE
D
R O
W (5
0' R
O W
U N
D
EV
EL
O
PE
D
R O
W (5
0' R
O W
XXXXXXXXXXXXXXXXXXXXXX
24" RCP INV 1.42
24" RCP INV 1.75
TURBIDITY BARRIER
MBMB
MB
800 CORBIN PARK RD
2209 LIVE OAK DR
785 CORBIN PARK RD
WM
DITCH CL
TOB
HOG WIRE FNECE
H O
G W
IR
E FEN
C E
C O
N C
D R
IVE
FH&WV
WV
2xW V
WM WM
18" RCP INV 2.81
SB AB-8
ELEV 5.81
WETLAND E1
(GIS)
EOP
EOP
DITCH CL
TOB DITCH CL
TOB
ROW
5.80 6.03
5.82 6.30
5.67 6.02
5.70
5.83
5.84 6.44
6.06
5.93 6.05
6.04
5.60 5.63
5.61
2.2
4.7
2.6
5.4 5.2
4.7 2.2
4.7
2.8 4.9
3.3
5.5
5.2
5.0 5.8
5.7
5.3
5.0 3.32.9
3.9
5.5 3.8
5.7 4.2
4.3 4.4
5.0 5.1
4 4
TH #05
2xWM
4''FM
4''FM
4''FM
4''FM 4''FM 4''FM
8''W 8''W 8''W 8''W
8''W 8''W
UT
UT UT UT UT
UT
x x x x x x x x x x x x x x x x x x
18''SD
OE
OE OE OE OE OE
123+00 124+00 125+00
126+00 127+00 128+00 129+00
XXXXXXXX
14"x23" CMP INV 3.00
14"x23" CMP INV 2.46
LI
VE
O
AK
D R
(5 0'
R O
W
PI
N
E
IS
LA
N
D D
R (5
0' R
O W
C-102
C O
R
BI
N P
AR
K
R O
AD
EX
IS
TI
N G
C O
N D
IT
IO
N S
D
EM
O
LI
TI
O N
P
LA
N
JW
ARM
MDTChecked By:
Drawn By:
Project No.:
Designed By:
w w w .te tra te ch .c om
M
AR
K D
AT
E
D
ES
C R
IP
TI
O N
BY
8/
/2
:2 2:
A
M
C :\U
SE
R
S\
TY
LE
R
.Y O
U N
G 1\
D C
\A C
C D
O C
S\
TE
TR
A
TE
C
H
IN
C \2
-4
-2
C
O R
BI
N
P
AR
K\ W
O R
KI
N
G F
IL
ES
\C
AD
\S H
EE
TF
IL
ES
\C -1
E
XI
ST
IN
G
C O
N D
IT
IO
N S
D
EM
O
LI
TI
O N
P
LA
N .D
W G
YO
U N
G , T
YL
ER
A
B
C
D
E
F
2 3 4 5 6 7
Bar Measures 1 inch
C op yr ig ht : T et ra
T ec h
200-41704-22002
C O
R
BI
N P
AR
K
ST
O
R M
W
AT
ER
M
AN
AG
EM
EN
T
IM
PR
O
VE
M
EN
TS
CI
TY
O F
NE
W
S M
YR
NA
B
EA
CH
EA
ST
P
IN
E
ST
R
EE
T, S
U
IT
E
O
R
LA
N D
O , F
L
PH
O
N E:
.8
.3
F
AX
: 4
.8
.3
M ic ha el
D . T ha tc he r, P.
E.
P.
E.
N o.
, F
L
Ea st
P in e St re et
, S ui te
O rla nd o, F lo rid a
En gi ne er in g Bu si ne ss N o.
D
AT
E
40'20' 80'0
N
40'20' 80'0
N
M
AT
C H
LI
N
E
- S
EE
S
H
EE
TC-
M
AT
C H
LI
N
E
- T
H
IS
S H
EE
T
M
AT
C H
LI
N
E
- S
EE
S
H
EE
TC-
M
AT
C H
LI
N
E
- T
H
IS
S H
EE
T
NOTES:
1. PIPE TO BE CUT AND CAPPED ON ANY
EXPOSED ENDS, AND REMOVED WHERE IN
CONFLICT WITH THE PROPOSED
IMPROVEMENTS. REMAINDER OF THE PIPE
SHALL BE GROUT FILLED AND ABANDONED IN
PLACE.
2. EROSION AND SEDIMENT CONTROL SHALL
CONSIST OF SILT FENCE, INLET PROTECTION,
AND TURBIDITY BARRIERS PER
SPECIFICATION SECTION 01568.
CORBIN PARK RD
(ROW VARIES)
C-501
REMOVAL LEGEND
INLET/MANHOLE TO
BE REMOVED
PIPE TO BE GROUT FILLED &
ABANDONED
PIPE TO BE REMOVED
TREE PROTECTION
TREE REMOVAL
ASPHALT MILL AND
RESURFACE
REMOVE AND REPLACE
EXISTING PAVEMENT
| | | | | | | | | | | CURB TO BE REMOVED
DRIVEWAY REMOVE
AND REPLACE
SHELL ROAD REMOVE
AND REPLACE
X X X X X
C-503
C-503
C-503
BENCHMARK ND LB26
N 1699391.7880 E 671220.1480
ELEV 7.24
MB MBMB
MBMB
FO
FOFO
G
MB MB MB MB MB
CHAIN LINK FNECE
CHAIN LINK FENCE
CHAIN LINK FENCE
CHAIN LINK FENCE
CHAIN LINK FENCE
C H
AIN
LIN
K FEN
C
E
CHAIN LINK FENCE
PLASTIC FENCE
12" CMP
W INV 3.78
E INV 3.75
CONC
DRIVE
WOOD POST FENCE24" H
ED
G E
MES
18" RCP INV 4.43
CHAIN LINK FENCE
24 HEDGEW
V
WM
WM
WM
WM
FOC BOX
2xTELE
CABINET
2xWM
WM
W M
WM
WM
WV
WV
FH
WM
2xWM
W M
MES
18" RCP INV 3.33
TO
B
D
ITC
H C
L
3xUNKNOWN UTILITY
W O
O D
PO
ST FEN
C E
OSW D3
UT
ASPH
ALT
D R
IVE
C O
N C
PAD
U N
PAVED
D
R
IVE
U N
PAVED
D
R
IVE
C O
N C
D R
IVE
C O
N C
D R
IVE
C O
N C
R O
AD
CONC
DRIVE
U N
PAVED
R
O
AD
TO
B
D
ITC
H C
L
TO
B
D
ITC
H C
L
TO
S
UNPAVED
DRIVE
TOB TOB
DITCH CL TOB
DITCH CL
R O
W
ROW
R O
W
ROW
U N
PAVED
D
R
IVE
U N
PAVED
D
R
IVE
UTILITY EASEMENT5.00' UTILITY EASEMENT 5.00' UTILITY EASEMENT
15.00' U
TILITY EASEM
EN
T
.0
0' U
TI
LI
TY
EA
SE
M
EN
T
EOP
C O
N C
D R
IVE
SS-1
TOP 5.80
ARV
TO
B
D
ITC
H C
L
5.32 5.57
5.50
5.51
6.456.06
6.08
5.96
6.55
6.69
6.12
6.04 5.56
6.32 6.20
6.49
6.39
6.18 6.04
5.0
4.3
5.5
4.0
5.8
5.9
4.05.6
6.7
5.0
6.0
5.8
3.9
5.4 5.2
5.4
3.3 5.6
5.8
5.43.7
5.9 5.7
5.6
5.6
6.0
5.8
5.8 5.3
5.4
5.1
6.4 5.8
6.3
6.0
4.7
6.4 5.8
6.2 3.8
6 7
TH #14
TH #17 @ 5.05'
SOIL BORING TH #16 @ 6.45'SOIL BORING TH #15 @ 3.25'
20"W
ELEC
PAN
EL
8" FM
16" CASING
8" FM
16" CASING
8" FM
16" CASING
MES
18" RCP INV 4.43
xx4''FM 4''FM xxxx
8''W
8''WUT UT
x xx
G G
G
20''R W
20''R W
FO
FO
FO
xx xx x
12''W
G G G G G
18''SD
OE
O E
O E
OE OE OE OE OE OE
OE
20''R W
4''FM
4''FM
4''FM
8''FM
(IN
16'' C
ASIN
G
8''FM
8''FM
4''FM
4''FM
4''FM
12''W
12''W 12''W 12''W 12''W 12''W 12''W
129+00 130+00 131+00 132+00 133+00 134+00 135+00 136+00 137+00
603+00 604+00
5+
606+00
XXXXXXXXXXX
X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
XXXXXXXXX
COR…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .