Bid Drawings Volume 7 of 14_L FLATWORK_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf

PDF 8 MB Posted

Attached to
Y1PZ--810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton National Cemetery
Solicitation number
36C78626B0007
Issued by

About this file

These are architectural bid documents for the Dayton National Cemetery Gravesite Expansion project. The documents comprise flatwork layout plans prepared by Anderson Consultants for the U.S. Department of Veterans Affairs, detailing concrete pavement, curbing, gates, walls, and associated site improvements.

The bid documents include four primary layout plans: the Columbarium "C" Flatwork Layout Plan showing an expansive paved area with light-duty concrete pavement, landscape edger curbs, cast-in-place concrete columns, control and expansion joints, and decorative aggregate flower strips; the Memorial Wall Flatwork Layout Plan depicting a rectangular memorial structure with similar concrete specifications; the Entry Wall Flatwork Layout Plan illustrating ornamental fencing, single-swing and vehicular gates, pedestrian access points, and associated concrete work; and the Entry Wall Flatwork Layout Plan sections showing detailed elevations for west and east wall configurations. General notes across all plans require contractors to submit paving sequence plans for engineer review and approval, notify the engineer of any discrepancies between drawings and field conditions, and coordinate construction joints at designated control joint locations. Control joints must remain continuous through landscape edger curbs, and expansion joints must be installed at all wall-to-flatwork interfaces. The specifications reference related drawings for light-duty concrete pavement (5/CS504), detectable warning panels (8/CS502), and curb details (8/LS504).

View the file

Other files

File Type Posted
36C78626B0007 0003.docx DOCX document
CG108 GRADING and DRAINAGE PLAN - PPC SECTION 51.pdf PDF
CD112 DEMOLITION PLAN - PPC SECTION 51.pdf PDF
CG106 GRADING and DRAINAGE PLAN - PPC SECTIONS 48 and 52.pdf PDF
LS400A.pdf PDF
LS204.pdf PDF
Revised Davis Bacon Wage Determination_Heavy_OH20260001 06252026.pdf PDF
LS401.pdf PDF
CG100.pdf PDF
CD111 DEMOLITION PLAN _ PPC SECTION 49 and 50.pdf PDF
LS402.pdf PDF
10 14 00 Exterior Signage.pdf PDF
S001.pdf PDF
LS301.pdf PDF
CS502 SITE DETAILS - 2.pdf PDF
01 43 39 Mockup Requirements.pdf PDF
ES101 - Electrical Site Plan.pdf PDF
Revised Davis Bacon Wage Determination_Building_OH20260093 05182026.pdf PDF
LS400B.pdf PDF
36C78626B0007 0002.docx DOCX document
36C78626B0007 0001.docx DOCX document
Prebid Site Visit Attendance Record_20260612.pdf PDF
LS200_Pages from 18125 DNC_BID_20260211.pdf PDF
LS300_Pages from 18125 DNC_BID_20260211.pdf PDF
Davis Bacon Wage Determination _ Building _ OH20260093 01022026.pdf PDF
Bid Drawings Volume 3 of 14_C LOGI DEMO_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Bid Drawings Volume 1 of 14_GEN SURV_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
36C78626B0007_1.docx DOCX document
Davis Bacon Wage Determination _ Heavy _ OH20260001 01022026.pdf PDF
Bid Specifications 810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Bid Drawings Volume 11 of 14_C GRADE UTIL_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Bid Drawings Volume 12 of 14_L PLANTING_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Bid Drawings Volume 6 of 14_L SITE PRECAST_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Bid Drawings Volume 5 of 14_C GRAVESITE_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Bid Drawings Volume 2 of 14_C BORING_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Bid Drawings Volume 8 of 14_L CAPS ADDRESSING_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Bid Drawings Volume 14 of 14_STRUC ELECT_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Bid Drawings Volume 13 of 14_IRRIGATION_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Bid Drawings Volume 10 of 14_L SECTIONS DETAILS_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Bid Drawings Volume 9 of 14_L ELEVATIONS_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
VAAR 852.219-75 VA Notice of Limitations On Subcontracting Certificate.docx DOCX document
IFB Cost Estimate Worksheet.xlsx XLSX spreadsheet
Bid Drawings Volume 4 of 14_C SITE_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Statement of Work 810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Show all 44

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CP3

CP2

CP1

CP6

CP4

CP5

LEGEND

DETECTABLE WARNING

PANEL; SEE 8/CS502

CONTROL JOINT;

SEE 7/CS504

BROOM DIRECTION

THICKENED EDGE

EXPANSION JOINT;

SEE 7/CS504

GENERAL NOTES

1.

2.

3.

4.

5.

IN THE EVENT OF ANY DISCREPANCIES

BETWEEN THE CONTRACT DRAWING LAYOUT

AND DIMENSIONING AND FIELD CONDITIONS

NOTIFY ENGINEER IMMEDIATELY.

CONSTRUCTION/COLD JOINTS WHERE

REQUIRED SHALL OCCURE AT CONTROL

JOINT LOCATION(S) SHOWN ON PLAN.

CONTRACTOR SHALL SUBMIT A PAVING

SEQUENCE PLAN FOR REVIEW AND

APPROVAL.

CONSTRUCTION JOINTS HAVE BEEN SHOWN

AS A RECOMMENDATION FOR SEQUENCING

OF POURS. CONSTRUCTION JOINTS MAY BE

SUBSTITUTED FOR CONTROL JOINTS BASED

ON PAVING SEQUENCE PLAN SUBMITTED BY

THE CONTRACTOR PRIOR TO PLACEMENT OF

CONCRETE.

CONTROL JOINTS ADJACENT TO LANDSCAPE

EDGER CURB SHALL BE CONTINUOUS ALL THE

WAY THROUGH THE CURB.

INSTALL EXPANSION JOINTS AT THE ENDS OF

ALL WALLS ABUTING CONCRETE FLATWORK.

CAST-IN-PLACE CONCRETE

COLUMN (TOW = TOP OF WALL)

DECORATIVE AGGREGATE

FLOWER STRIP

LIGHT DUTY CONCRETE

PAVEMENT; SEE 5/CS504

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

90.00°

6'- 3 1

/4"

6' CONCRETE SIDEWALK; SEE

CIVIL SITE PLAN

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID DOCUMENTS

Office of

Design and Construction

Services U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS

321 4 5 6 7 8 9 10

IRRIGATION:

WATER IN

MOTION, INC.

GEOTECHNICAL:

TERRACON

COST ESTIMATING:

OCMI

175 JAMES AVENUE NORTH

MINNEAPOLIS, MN 55405

952.229.1911

TIMOTHY MALOOLY

611 LUNKEN PARK DRIVE

CINCINNATI, OHIO 45226

513.612.9020

JEFF DUNLAP, PE

2100 NORTH GREENVILLE AVENUE

RICHARDSON, TEXAS 75082

469.431.0571

KYLE VEATER

BID DOCUMENTS

C :\U se rs

\rl ie be lt\

D oc um en ts \1

D N

C C ol um ba riu m _R

JL

ie be lt4

8.

rv t

-0 2-

:1 8:

PM

COLUMBARIUM - FLATWORK

LAYOUT PLAN

DAYTON NATIONAL CEMETERY

GRAVESITE EXPANSION

4400 W THIRD ST, DAYTON, OH 45428

810CM3033

DECEMBER 5, 2025 JAF RJL18125

LS120

1 LANDSCAPE EDGER CURB; SEE 8/LS504

KEYNOTES

DESCRIPTION#

NOTES:

2 PLANTING BED; SEE GRADING AND

PLANTING PLANS

1/4" = 1'-0"1 COLUMBARIUM 'C' - FLATWORK LAYOUT PLAN 0 4' 8'2'

TRUE

NORTH

3 FLOWER WATER STATION; SEE 1/CS502

Revisions: Date:

LEGEND

GENERAL NOTES

1.

2.

3.

IN THE EVENT OF ANY DISCREPANCIES BETWEEN

THE CONTRACT DRAWING LAYOUT AND

DIMENSIONING AND FIELD CONDITIONS NOTIFY

ENGINEER IMMEDIATELY.

CONSTRUCTION/COLD JOINTS WHERE REQUIRED

SHALL OCCURE AT CONTROL JOINT LOCATION(S)

SHOWN ON PLAN. IF NEEDED ELSE WHERE,

CONTRACTOR SHALL SUBMIT A PAVING SEQUENCE

PLAN FOR REVIEW AND APPROVAL.

CONTROL JOINTS ADJACENT TO LANDSCAPE

EDGER CURB SHALL BE CONTINUOUS ALL THE WAY

THROUGH THE CURB

DETECTABLE WARNING

PANEL; SEE 8/CS502

CONTROL JOINT;

SEE 7/CS504

BROOM DIRECTION

THICKENED EDGE

EXPANSION JOINT;

SEE 7/CS504

CAST-IN-PLACE CONCRETE

COLUMN (TOW = TOP OF WALL)

DECORATIVE AGGREGATE

FLOWER STRIP

LIGHT DUTY CONCRETE

PAVEMENT; SEE 5/CS504

9'- 0"

4'-0" 7'-6" 16'-2" 7'-6"

EQ EQ EQ

TYP.

6"

35'-2"

'-1

1 5 /8"

TYP.

6"

LS504

7'- 9 1

/8" 4'-

8 1 /2"

2'- 6"

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID DOCUMENTS

Office of

Design and Construction

Services U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS

321 4 5 6 7 8 9 10

IRRIGATION:

WATER IN

MOTION, INC.

GEOTECHNICAL:

TERRACON

COST ESTIMATING:

OCMI

175 JAMES AVENUE NORTH

MINNEAPOLIS, MN 55405

952.229.1911

TIMOTHY MALOOLY

611 LUNKEN PARK DRIVE

CINCINNATI, OHIO 45226

513.612.9020

JEFF DUNLAP, PE

2100 NORTH GREENVILLE AVENUE

RICHARDSON, TEXAS 75082

469.431.0571

KYLE VEATER

BID DOCUMENTS

C :\U se rs

\rl ie be lt\

D oc um en ts \1

D N

C M em or ia l W al l_

R

_R

JL

ie be lt4

8.

rv t

-0

2-

:1

6:

PM

MEMORIAL WALL - FLATWORK

LAYOUT

DAYTON NATIONAL CEMETERY

GRAVESITE EXPANSION

4400 W THIRD ST, DAYTON, OH 45428

810CM3033

DECEMBER 5, 2025 JD RJL18125

LS121

2 LANDSCAPE EDGER CURB, SEE 8/LS504

KEYNOTES

DESCRIPTION#

1 FLUSH CURB TRANSITION, SEE 6/CS504

1/2" = 1'-0"1 MEMORIAL WALL - FLATWORK LAYOUT PLAN

3 FLOWER WATER STATION; SEE 1/CS502

0 2' 4'1'

TRUE

NORTH

CP1

CP3

CP4

CP2

LEGEND

CONTROL JOINT; SEE

7/CS504

GENERAL NOTES

1.

2.

IN THE EVENT OF ANY DISCREPANCIES BETWEEN

THE CONTRACT DRAWING LAYOUT AND

DIMENSIONING AND FIELD CONDITIONS NOTIFY

ENGINEER IMMEDIATELY.

CONSTRUCTION/COLD JOINTS WHERE REQUIRED

SHALL OCCURE AT CONTROL JOINT LOCATION(S)

SHOWN ON PLAN. CONTRACTOR SHALL SUBMIT A

PAVING SEQUENCE PLAN FOR REVIEW AND

APPROVAL

KEYNOTES

Description#

1 ORNAMENTAL FENCING; SEE 1/CS503

2 ORNAMENTAL SINGLE-SWING GATE TO BE

CONNECTED TO DOUBLE-SWING

VEHICULAR GATE; SEE 2/CS503

3 LANDSCAPE MAINTANACE EDGER, SEE

5/CS504

4 LANDSCAPE EDGER TO MEET ENTRY

WALL WITH EXPANSION JOINT, SEE

7/CS504 & 5/LS502

EXPANSION JOINT; SEE

7/CS504

5 LANDSCAPE EDGER TO MEET ENTRY

CURB WITH EXPANSION JOINT, SEE 5 &

7/CS504

BROOM DIRECTION

THICKENED EDGE

CAST-IN-PLACE CONCRETE

COLUMN (TOW = TOP OF WALL)

LIGHT DUTY CONCRETE

PAVEMENT; SEE 5/CS504

-- GRIDLINE

CAST-IN-PLACE CONCRETE STEM

WALLS (TSW = TOP OF STEM WALL)

2'-2 3/4"

NORTH FACE OF ENTRY WALL

CEMETERY NAME PLATE

CONCRETE TO MEET EDGE

OF EXISTING WALKING

PATH WITH EXPANSION

JOINT

3'-2 7/8" EQ EQ EQ 2'-3 1/2"

4'-8 1/8" 4'-8"2'-3 1/2"EQ EQ EQ3'-2 7/8"

1'- 0 3

/4" 3'-

6" 1'-

0 3 /4"

1'- 0 3

/4" 3'-

6" 1'-

0 3 /4"

1'-0"

A B C

5'- 7 1

/2"

ORNAMENTAL

PEDESTRIAN GATE; SEE

2/CS503

ORNAMENTAL

DRIVE GATE; SEE

3/ CS503

CONCRETE TO MEET BACK OF

CURB WITH EXPANSION JOINT

NORTH FACE OF ENTRY WALL

VA SEAL

3 4

5'-6 7/8" 5'-7 3/8"

EQ EQ

4'- 0"

2'-3 1/2" EQ EQ EQ 3'-3 1/4"

1'- 0 3

/4" 3'-

6" 1'-

0 3 /4"

3'-3 1/4"2'-3 1/2" EQ EQ EQ

1'- 0 3

/4" 3'-

6" 1'-

0 3 /4"

D E F

ORNAMENTAL

DRIVE GATE; SEE

3/CS503

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID DOCUMENTS

Office of

Design and Construction

Services U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS

321 4 5 6 7 8 9 10

IRRIGATION:

WATER IN

MOTION, INC.

GEOTECHNICAL:

TERRACON

COST ESTIMATING:

OCMI

175 JAMES AVENUE NORTH

MINNEAPOLIS, MN 55405

952.229.1911

TIMOTHY MALOOLY

611 LUNKEN PARK DRIVE

CINCINNATI, OHIO 45226

513.612.9020

JEFF DUNLAP, PE

2100 NORTH GREENVILLE AVENUE

RICHARDSON, TEXAS 75082

469.431.0571

KYLE VEATER

BID DOCUMENTS

C :\U se rs

\rl ie be lt\

D oc um en ts \1

D N

C E nt ry

W al l_ R

_R

JL

ie be lt4

8.

rv t

-0 2-

:2 4:

PM

ENTRY WALL - FLATWORK LAYOUT

PLAN

DAYTON NATIONAL CEMETERY

GRAVESITE EXPANSION

4400 W THIRD ST, DAYTON, OH 45428

810CM3033

DECEMBER 5, 2025 JAF RJL18125

LS122

0 4' 8'2'

TRUE

NORTH

1/2" = 1'-0"1 ENTRY WALL - FLATWORK LAYOUT PLAN - WEST WALL

1/2" = 1'-0"2 ENTRY WALL - FLATWORK LAYOUT PLAN - EAST WALL

0 4' 8'2'

TRUE

NORTH

File details come from the government source that posted it. Updated .