This is a bid document containing site detail drawings and specifications for the Dayton National Cemetery Gravesite Expansion project, issued February 5, 2026. The document is part of a larger set of bid documents (37 of 159 pages) prepared by Anderson Engineering of Minnesota, LLC under Project Number 18125, Drawing Number 810-CM3-033.

The project specifies installation of trash and flower vase receptacles at the cemetery, with detailed construction and design requirements. Trash receptacles must be Victor Stanley S-42 or approved equal units mounted on concrete pad anchors with stainless steel expansion shields and bolts. Flower vase receptacles require custom hinged lids. Both receptacle types require decals with white lettering in Optima Bold typeface (1-1/2" high) on all four sides, with banding colors matching existing Columbarium A installations. Additional infrastructure includes 5-inch thick reinforced concrete pads with medium broom finish, geotextile fabric, decorative beach pebble, drainage tile connections, and irrigation water supply lines. The document also includes detailed "Do Not Drink" warning signage specifications and comprehensive floral regulations for cemetery use, including restrictions on potted plants (Easter and Memorial Day only), artificial flowers (October 10–April 15 only), wreaths and grave blankets (December 1–January 20 only), and year-round allowances for fresh flowers and American flags. Final signage language requires cemetery approval. The work is under the U.S. Department of Veterans Affairs, Office of Design and Construction Services.

View the file

Other files

File Type Posted
36C78626B0007 0003.docx DOCX document
CG108 GRADING and DRAINAGE PLAN - PPC SECTION 51.pdf PDF
CD112 DEMOLITION PLAN - PPC SECTION 51.pdf PDF
CG106 GRADING and DRAINAGE PLAN - PPC SECTIONS 48 and 52.pdf PDF
LS400A.pdf PDF
LS204.pdf PDF
Revised Davis Bacon Wage Determination_Heavy_OH20260001 06252026.pdf PDF
LS401.pdf PDF
CG100.pdf PDF
CD111 DEMOLITION PLAN _ PPC SECTION 49 and 50.pdf PDF
LS402.pdf PDF
10 14 00 Exterior Signage.pdf PDF
S001.pdf PDF
LS301.pdf PDF
01 43 39 Mockup Requirements.pdf PDF
ES101 - Electrical Site Plan.pdf PDF
Revised Davis Bacon Wage Determination_Building_OH20260093 05182026.pdf PDF
LS400B.pdf PDF
36C78626B0007 0002.docx DOCX document
36C78626B0007 0001.docx DOCX document
Prebid Site Visit Attendance Record_20260612.pdf PDF
LS200_Pages from 18125 DNC_BID_20260211.pdf PDF
LS300_Pages from 18125 DNC_BID_20260211.pdf PDF
Davis Bacon Wage Determination _ Building _ OH20260093 01022026.pdf PDF
Bid Drawings Volume 3 of 14_C LOGI DEMO_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Bid Drawings Volume 1 of 14_GEN SURV_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
36C78626B0007_1.docx DOCX document
Davis Bacon Wage Determination _ Heavy _ OH20260001 01022026.pdf PDF
Bid Specifications 810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Bid Drawings Volume 11 of 14_C GRADE UTIL_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Bid Drawings Volume 12 of 14_L PLANTING_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Bid Drawings Volume 6 of 14_L SITE PRECAST_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Bid Drawings Volume 5 of 14_C GRAVESITE_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Bid Drawings Volume 2 of 14_C BORING_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Bid Drawings Volume 8 of 14_L CAPS ADDRESSING_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Bid Drawings Volume 14 of 14_STRUC ELECT_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Bid Drawings Volume 13 of 14_IRRIGATION_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Bid Drawings Volume 10 of 14_L SECTIONS DETAILS_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Bid Drawings Volume 9 of 14_L ELEVATIONS_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Bid Drawings Volume 7 of 14_L FLATWORK_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
VAAR 852.219-75 VA Notice of Limitations On Subcontracting Certificate.docx DOCX document
IFB Cost Estimate Worksheet.xlsx XLSX spreadsheet
Bid Drawings Volume 4 of 14_C SITE_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Statement of Work 810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Show all 44

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NOTE:

-MINIMUM 1'-6" FROM

EDGES OF SIDEWALK

Trash

SEE PLAN VIEW

Flower Vases

CS502

2' -3

2' -8

5 8"

CONCRETE PAD

ANCHOR RECEPTACLES

W/STAINLESS STEEL

EXPANSION SHIELDS &

BOLTS PER

MANUFACTURER

SIGN FOR "TRASH" AS NOTED.

CLEAR DECAL W/ WHITE

LETTERING, OPTIMA BOLD

TYPEFACE 1-1/2" HIGH.

DECAL SHALL BE LOCATED ON

4 SIDES OF EACH

RECEPTACLE. BANDING

COLOR TO MATCH FWS AT

COLUMBARIUM A.

ELEVATION VIEW

VICTOR STANLEY S-42

OR APPROVED EQUAL

VICTOR STANLEY S-424

OR APPROVED EQUAL

SIGN FOR "FLOWER VASES" AS NOTED.

CLEAR DECAL W/ WHITE LETTERING, OPTIMA

BOLD TYPEFACE 1-1/2" HIGH. DECAL SHALL BE

LOCATED ON 4 SIDES OF EACH RECEPTACLE.

BANDING COLOR TO MATCH FWS AT

COLUMBARIUM A.

BRONZE WATER SPIGOT

3/4 INCH COMPRESSION

JUG FILLER,SELF-CLOSING

LEVER HANDLE

"DO NOT DRINK" SIGN

SHUT-OFF VALVE

HANDLE

SEE PLAN VIEW SEE PLAN VIEW

Flower Vases

FINISHED GRADE

2' -5

1'-2"

3/4" TYPE K COPPER PIPING

BRICK (CONTINUOUS

AROUND BOTTOM OF

VALVE BOX

3/4" OR 1-1/2" TYPE K COPPER

(SEE PLANS FOR SIZE.

LENGTH AS REQUIRED)

MAINLINE WATER

MAIN PIPE (SEE

PLANS FOR SIZE)

ADJUSTABLE PRESSURE REGULATOR

4" THREADED CURB STOP VALVE

3/4" DOMESTIC WATER SUPPLY

LINE; SEE IRRIGATION DRAWINGS

CONCRETE FOOTING

STEEL FINS, WELD TO

STEEL TUBING

GEOTEXTILE FABRIC

SECURE WITH ADHESIVES

1/2" DECORATIVE

BEACH PEBBLE

4" AGGREGATE BASE

COMPACTED SUBGRADE

12" STRUCTURAL FILL

5" THICK CONCRETE APRON (IGC ONLY)

2"

CONNECT 4" PERF.

DRAINTILE WITH SOCK TO

COLUMBARIA UNDERDRAINS.CROSS-SECTION VIEW

4'-0"

1' -0

1-1 2" x 34" COPPER REDUCER (AS REQUIRED) 3" MIN DEPTH OF 34 "

WASHED GRAVEL

FILTER FABRIC

8" WASHED ROUND GRAVEL

PVC PIPE RISER

8" WASHED ROUND GRAVEL

12" X 22" CONCRETE

VALVE BOX WITH METAL LID

SEE PLAN VIEW FOR LOCATION

2% MAX SLOPE

EITHER

DIRECTION

8'-115 8"

4' -0

6"

8"

3'-11 2"

UNLESS NOTED

OTHERWISE

6"

6"

2' -3

5 8"1' -6

2'

-0

2'-0"

FLORAL REGULATIONS

DETAIL. SEE 3/CS502.

5" THICK REINFORCED CONC. PAD W/ 1/4"

RADIUS @ EDGE, TYP. MEDIUM BROOM

FINISH, RUB OUT ALL SURFACE TOOL MARKS

TRASH RECEPTACLE:

TAPERED DOME LID

W/SELF-CLOSING DOOR

PLAN VIEW FWS

SPLASH AREA AGGREGATE

TO MATCH EXISTING FLOWER

WATERING STATIONS

FLOWER VASE RECEPTACLE W/ CUSTOM

HINGED LID & FLORAL DECALS

5" THICK

CONCRETE

APRON5'

-3

VALVE BOX

(LOCATION PER PLAN

AP

R

O N

A T

PP

C

, I G

C , T

R

AD

; N O

AP

PR

O N

A T

C O

LU

M

BA

R

IU

M

O R

M

EM

O R

IA

L

W

AL

L

FLORAL

REGULATIONSHANDLE

1/3" SQUARE HOLE

FOR ANCHOR BOLT

TRASH RECEPTACLE:

TAPERED DOME LID W/

SELF-CLOSING DOOR

FLOWER VASE RECEPTACLE:

CUSTOM HINGED LID

W/FLORAL DECALS

HANDLE

TOP VIEW

BOTTOM VIEW

4"

Do Not Drink3"

EQ. EQ.

R 1 2

3/4" HT. LETTERING, OPTIMA

BOLD TYPE FACE, INITIAL

CAP AND LOWER CASE; SEE

SIGNAGE SCHEDULE FOR

COPY

ALUMINUM SIGN PANEL

WELDED TO CONTINUOUS

CURVED FRAME; SEE

SPECIFICATIONS FOR

COLOR & FINISH

1/8" THICK ALUMINUM

SIGN PANEL

3 4"

1/

2"

1'-0"

EQ EQ

FLORAL

REGULATIONS

DAYTON NATIONAL CEMETERY FLORAL POLICY

SAFETY HAZARD

PLEASE,

ITEMS SUCH AS THESE

distract from the dignity of your National Cemetery and may create a

POTTED PLANTS

10 days before to 10 days after Easter and

Memorial Day

HOLIDAY WREATHS

and/or

GRAVE BLANKETS

DEC 1 - JAN 20

ITEMS THAT ARE NOT PERMITTED

EASTER, MEMORIAL DAY, WINTER HOLIDAYS ONLY

YEAR-ROUND DECORATIONS

HELP US MAINTAIN

THE SOLEMN DIGNITY OF

OUR VETERANS'

FINAL RESTING PLACE

AT THIS NATIONAL SHRINE

8"

ONE U.S. FLAG and/or

FRESH FLOWERS IN CONES

Always welcome

ARTIFICIAL FLOWERS

OCT 10 - APR 15

Only

3 4"

4"

1/

2"

1/ 2"

3 4"

4"

· Up to four floral arrangements accompanying the casket or urn at the time of burial will be placed on the grave and removed when they become unsightly.

· Natural, fresh-cut flowers may be placed on graves at any time of the year and will be removed when they become unsightly or to facilitate mowing.

· Plastic floral cones are available for use within the cemetery and are located in containers throughout the cemetery.

· One small American flag may be placed on the grave, will be removed only when it is damaged, faded, or tattered, and will be disposed of properly.

· No object shall be attached to a grave marker or niche cover, protrude above the top of and upright headstone or encroach on an adjacent grave.

· Artificial flowers may be placed on graves October 10 through April 15 only, during non-mowing season when they do not present a safety hazard.

· Potted plants may be placed on graves 10 days before to 10 days after Easter Sunday and memorial day only.

· Christmas wreaths and grave blankets my be placed on graves December 1 through January 20 only.

· Permanent plantings, statues, battery or solar-powered items, balloons, breakable objects, and other commemorative items are not permitted at any time.

· The department of veterans affairs does not permit adornments that are offensive, inconsistent with the dignity of the cemetery or may be a safety hazard.

· On the first and third Wednesday of each month cemetery personnel will inspect each grave for unsightly or unauthorized items.

· Durable items removed from graves will be held for one month. These items remain property of the donor but are under custodianship of the cemetery.

If not claimed within 30 days, they are then governed by the rules for disposal of federal property.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fil e P ath : y

:\1

\18

5 v a n ca m idw es t -da yto n n ati on al ce me ter y -da yto n o hio

\_0 7 c ivi l\_ ca d f ile s\_ sh ee ts\

5_ c_ sit e.d wg e dit :m mi lle r sa ve d:7 /6/

:29

P M

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS

321 4 5 6 7 8 9 10

Project Director

Revisions:

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18125

810-CM3-033

FEBRUARY 5, 2026

4400 W THIRD ST, DAYTON, OH 45428

BID DOCUMENTS

Date:

OF 159

Office of Design and Construction

Services

BID DOCUMENTS

DAYTON NATIONAL CEMETERY

GRAVESITE EXPANSIONGEOTECHNICAL

TERRACON

JEFF DUNLAP, PE

IRRIGATION

WATER IN

MOTION, INC.

TIMOTHY MALOOLY

COST ESTIMATING

OCMI

KYLE VEATER

175 James Avenue North Minneapolis, MN 55405 952.229.1911

611 Lunken Park Drive Cincinnati, Ohio 45226 513.612.9020

2100 North Greenville Ave. Richardson, Texas

75082 469.431.0571 CS502

SITE DETAILS - 2

SCALE:1

FLOWER WATER STATION

N.T.S.

SCALE:2

DO NOT DRINK SIGN

N.T.S.

SCALE:3

FLORAL REGULATIONS DECALS

N.T.S.

BJNJAF

NOTE: FINAL LANGUAGE SHALL BE REVIEWED AND APPROVED BY CEMETERY.

2 ADDENDUM 2 7/8/26

PM Revisions: Date:

AMENDMENT 02 7/8/20262

Sheets and Views