This is a bid document containing site detail drawings and specifications for the Dayton National Cemetery Gravesite Expansion project, issued February 5, 2026. The document is part of a larger set of bid documents (37 of 159 pages) prepared by Anderson Engineering of Minnesota, LLC under Project Number 18125, Drawing Number 810-CM3-033.
The project specifies installation of trash and flower vase receptacles at the cemetery, with detailed construction and design requirements. Trash receptacles must be Victor Stanley S-42 or approved equal units mounted on concrete pad anchors with stainless steel expansion shields and bolts. Flower vase receptacles require custom hinged lids. Both receptacle types require decals with white lettering in Optima Bold typeface (1-1/2" high) on all four sides, with banding colors matching existing Columbarium A installations. Additional infrastructure includes 5-inch thick reinforced concrete pads with medium broom finish, geotextile fabric, decorative beach pebble, drainage tile connections, and irrigation water supply lines. The document also includes detailed "Do Not Drink" warning signage specifications and comprehensive floral regulations for cemetery use, including restrictions on potted plants (Easter and Memorial Day only), artificial flowers (October 10–April 15 only), wreaths and grave blankets (December 1–January 20 only), and year-round allowances for fresh flowers and American flags. Final signage language requires cemetery approval. The work is under the U.S. Department of Veterans Affairs, Office of Design and Construction Services.
View the file
Other files
Show all 44
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NOTE:
-MINIMUM 1'-6" FROM
EDGES OF SIDEWALK
Trash
SEE PLAN VIEW
Flower Vases
CS502
2' -3
2' -8
5 8"
CONCRETE PAD
ANCHOR RECEPTACLES
W/STAINLESS STEEL
EXPANSION SHIELDS &
BOLTS PER
MANUFACTURER
SIGN FOR "TRASH" AS NOTED.
CLEAR DECAL W/ WHITE
LETTERING, OPTIMA BOLD
TYPEFACE 1-1/2" HIGH.
DECAL SHALL BE LOCATED ON
4 SIDES OF EACH
RECEPTACLE. BANDING
COLOR TO MATCH FWS AT
COLUMBARIUM A.
ELEVATION VIEW
VICTOR STANLEY S-42
OR APPROVED EQUAL
VICTOR STANLEY S-424
OR APPROVED EQUAL
SIGN FOR "FLOWER VASES" AS NOTED.
CLEAR DECAL W/ WHITE LETTERING, OPTIMA
BOLD TYPEFACE 1-1/2" HIGH. DECAL SHALL BE
LOCATED ON 4 SIDES OF EACH RECEPTACLE.
BANDING COLOR TO MATCH FWS AT
COLUMBARIUM A.
BRONZE WATER SPIGOT
3/4 INCH COMPRESSION
JUG FILLER,SELF-CLOSING
LEVER HANDLE
"DO NOT DRINK" SIGN
SHUT-OFF VALVE
HANDLE
SEE PLAN VIEW SEE PLAN VIEW
Flower Vases
FINISHED GRADE
2' -5
1'-2"
3/4" TYPE K COPPER PIPING
BRICK (CONTINUOUS
AROUND BOTTOM OF
VALVE BOX
3/4" OR 1-1/2" TYPE K COPPER
(SEE PLANS FOR SIZE.
LENGTH AS REQUIRED)
MAINLINE WATER
MAIN PIPE (SEE
PLANS FOR SIZE)
ADJUSTABLE PRESSURE REGULATOR
4" THREADED CURB STOP VALVE
3/4" DOMESTIC WATER SUPPLY
LINE; SEE IRRIGATION DRAWINGS
CONCRETE FOOTING
STEEL FINS, WELD TO
STEEL TUBING
GEOTEXTILE FABRIC
SECURE WITH ADHESIVES
1/2" DECORATIVE
BEACH PEBBLE
4" AGGREGATE BASE
COMPACTED SUBGRADE
12" STRUCTURAL FILL
5" THICK CONCRETE APRON (IGC ONLY)
2"
CONNECT 4" PERF.
DRAINTILE WITH SOCK TO
COLUMBARIA UNDERDRAINS.CROSS-SECTION VIEW
4'-0"
1' -0
1-1 2" x 34" COPPER REDUCER (AS REQUIRED) 3" MIN DEPTH OF 34 "
WASHED GRAVEL
FILTER FABRIC
8" WASHED ROUND GRAVEL
PVC PIPE RISER
8" WASHED ROUND GRAVEL
12" X 22" CONCRETE
VALVE BOX WITH METAL LID
SEE PLAN VIEW FOR LOCATION
2% MAX SLOPE
EITHER
DIRECTION
8'-115 8"
4' -0
6"
8"
3'-11 2"
UNLESS NOTED
OTHERWISE
6"
6"
2' -3
5 8"1' -6
2'
-0
2'-0"
FLORAL REGULATIONS
DETAIL. SEE 3/CS502.
5" THICK REINFORCED CONC. PAD W/ 1/4"
RADIUS @ EDGE, TYP. MEDIUM BROOM
FINISH, RUB OUT ALL SURFACE TOOL MARKS
TRASH RECEPTACLE:
TAPERED DOME LID
W/SELF-CLOSING DOOR
PLAN VIEW FWS
SPLASH AREA AGGREGATE
TO MATCH EXISTING FLOWER
WATERING STATIONS
FLOWER VASE RECEPTACLE W/ CUSTOM
HINGED LID & FLORAL DECALS
5" THICK
CONCRETE
APRON5'
-3
VALVE BOX
(LOCATION PER PLAN
AP
R
O N
A T
PP
C
, I G
C , T
R
AD
; N O
AP
PR
O N
A T
C O
LU
M
BA
R
IU
M
O R
M
EM
O R
IA
L
W
AL
L
FLORAL
REGULATIONSHANDLE
1/3" SQUARE HOLE
FOR ANCHOR BOLT
TRASH RECEPTACLE:
TAPERED DOME LID W/
SELF-CLOSING DOOR
FLOWER VASE RECEPTACLE:
CUSTOM HINGED LID
W/FLORAL DECALS
HANDLE
TOP VIEW
BOTTOM VIEW
4"
Do Not Drink3"
EQ. EQ.
R 1 2
3/4" HT. LETTERING, OPTIMA
BOLD TYPE FACE, INITIAL
CAP AND LOWER CASE; SEE
SIGNAGE SCHEDULE FOR
COPY
ALUMINUM SIGN PANEL
WELDED TO CONTINUOUS
CURVED FRAME; SEE
SPECIFICATIONS FOR
COLOR & FINISH
1/8" THICK ALUMINUM
SIGN PANEL
3 4"
1/
2"
1'-0"
EQ EQ
FLORAL
REGULATIONS
DAYTON NATIONAL CEMETERY FLORAL POLICY
SAFETY HAZARD
PLEASE,
ITEMS SUCH AS THESE
distract from the dignity of your National Cemetery and may create a
POTTED PLANTS
10 days before to 10 days after Easter and
Memorial Day
HOLIDAY WREATHS
and/or
GRAVE BLANKETS
DEC 1 - JAN 20
ITEMS THAT ARE NOT PERMITTED
EASTER, MEMORIAL DAY, WINTER HOLIDAYS ONLY
YEAR-ROUND DECORATIONS
HELP US MAINTAIN
THE SOLEMN DIGNITY OF
OUR VETERANS'
FINAL RESTING PLACE
AT THIS NATIONAL SHRINE
8"
ONE U.S. FLAG and/or
FRESH FLOWERS IN CONES
Always welcome
ARTIFICIAL FLOWERS
OCT 10 - APR 15
Only
3 4"
4"
1/
2"
1/ 2"
3 4"
4"
· Up to four floral arrangements accompanying the casket or urn at the time of burial will be placed on the grave and removed when they become unsightly.
· Natural, fresh-cut flowers may be placed on graves at any time of the year and will be removed when they become unsightly or to facilitate mowing.
· Plastic floral cones are available for use within the cemetery and are located in containers throughout the cemetery.
· One small American flag may be placed on the grave, will be removed only when it is damaged, faded, or tattered, and will be disposed of properly.
· No object shall be attached to a grave marker or niche cover, protrude above the top of and upright headstone or encroach on an adjacent grave.
· Artificial flowers may be placed on graves October 10 through April 15 only, during non-mowing season when they do not present a safety hazard.
· Potted plants may be placed on graves 10 days before to 10 days after Easter Sunday and memorial day only.
· Christmas wreaths and grave blankets my be placed on graves December 1 through January 20 only.
· Permanent plantings, statues, battery or solar-powered items, balloons, breakable objects, and other commemorative items are not permitted at any time.
· The department of veterans affairs does not permit adornments that are offensive, inconsistent with the dignity of the cemetery or may be a safety hazard.
· On the first and third Wednesday of each month cemetery personnel will inspect each grave for unsightly or unauthorized items.
· Durable items removed from graves will be held for one month. These items remain property of the donor but are under custodianship of the cemetery.
If not claimed within 30 days, they are then governed by the rules for disposal of federal property.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fil e P ath : y
:\1
\18
5 v a n ca m idw es t -da yto n n ati on al ce me ter y -da yto n o hio
\_0 7 c ivi l\_ ca d f ile s\_ sh ee ts\
5_ c_ sit e.d wg e dit :m mi lle r sa ve d:7 /6/
:29
P M
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18125
810-CM3-033
FEBRUARY 5, 2026
4400 W THIRD ST, DAYTON, OH 45428
BID DOCUMENTS
Date:
OF 159
Office of Design and Construction
Services
BID DOCUMENTS
DAYTON NATIONAL CEMETERY
GRAVESITE EXPANSIONGEOTECHNICAL
TERRACON
JEFF DUNLAP, PE
IRRIGATION
WATER IN
MOTION, INC.
TIMOTHY MALOOLY
COST ESTIMATING
OCMI
KYLE VEATER
175 James Avenue North Minneapolis, MN 55405 952.229.1911
611 Lunken Park Drive Cincinnati, Ohio 45226 513.612.9020
2100 North Greenville Ave. Richardson, Texas
75082 469.431.0571 CS502
SITE DETAILS - 2
SCALE:1
FLOWER WATER STATION
N.T.S.
SCALE:2
DO NOT DRINK SIGN
N.T.S.
SCALE:3
FLORAL REGULATIONS DECALS
N.T.S.
BJNJAF
NOTE: FINAL LANGUAGE SHALL BE REVIEWED AND APPROVED BY CEMETERY.
2 ADDENDUM 2 7/8/26
PM Revisions: Date:
AMENDMENT 02 7/8/20262