Bid Drawings Volume 10 of 14_L SECTIONS DETAILS_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf
PDF 10 MB Posted
- Solicitation number
- 36C78626B0007
About this file
This document is a comprehensive set of architectural construction details and specifications for the Dayton National Cemetery Gravestie Expansion project, prepared by Anderson Architect/Engineer of Record under the U.S. Department of Veterans Affairs.
The bid documents contain detailed construction drawings and specifications for memorial walls, columbarium units, entry walls, and associated stonework. Key structural components include cast-in-place concrete stem walls and column stems; Stone Type 1 (full veneer) and Stone Type 2 (ashlar) stone veneers with 3/8" concave mortar joints; precast concrete columbarium niche units with stainless steel embedded weld plates and rosette attachment systems; natural stone caps with varying profiles (Type C1, C2, M1, M4, E2); and ornamental fencing at entry locations. The work involves field drilling and epoxy stainless steel pin installation for stone cap setting, continuous self-adhesive EPDM membrane installation, sealant application with backer rods, and installation of stainless steel masonry ties. Specifications require smooth sawn finishes with 1/8" eased edges on all visible stone surfaces, continuous termination bars, type 1 cell vents at joint locations, damp proofing extending to spread footings, free-draining aggregate backfill, and decorative aggregate flower strips. The columbarium units feature precast concrete construction with 8" diameter clear acrylic niche covers, stainless steel rosette and bolt fastening systems, and tamper-proof anchoring details. Memorial wall plaques include marble border stones and stone marker installations with specific dimensional requirements. Detailed cap profiles, column enlargement details, wall base conditions, and softscape section details are provided for multiple wall configurations throughout the cemetery expansion area.
View the file
Other files
Show all 44
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STONE TYPE 1: SINGLE-SIDED
STONE CAP
FINISH GRADE
STONE TYPE 1: BASE STONE
PRECAST CONCRETE MARKER
WALL
STONE TYPE 2: ASHLAR
MARBLE MARKER, TYP.
(VA SUPPLIED)
4" HDPE PERFORATED DRAINTILE
ROSETT MARKER BOLT, TYP.
(VA SUPPLIED)
DECORATIVE AGGREGATE
FLOWER STRIP
THICKENED EDGE
CONCRETE PAVEMENT
FREE-DRAINING AGGREGATE/
GRANULAR DRAINAGE BACKFILL
LS301
LS502
TYP
LS301
TYP
TSW
SEE STRUCTURAL
ANCHOR CAP INTO
CAST-IN-PLACE
CONCRETE
STONE TYPE 1:
END COLUMN STONE CAP
STONE TYPE 1:
END COLUMN FULL VENEER
FINISH GRADE
C.I.P. CONCRETE STEM WALL
DECORATIVE AGGREGATE
FLOWER STRIP
THICKENED EDGE
CONCRETE PAVEMENT
FREE-DRAINING AGGREGATE/
GRANULAR DRAINAGE BACKFILL
LS301
TYP
LS502
TYP
TSW
SEE STRUCTURAL
LS503
TYP
STAINLESS STEEL MASONRY TIES, TYP.
FIELD DRILL AT LOCATION AND ANGLE
AS PER STONE CAP MANUFACTURER,
EPOXY STAINLESS PIN IN-PLACE
3/8" SEALANT W/BACKER ROD, CONT.
ALONG CAP JOINT.
CONT. SELF
ADHESIVE EPDM
CAST-IN-PLACE CONCRETE.
STEM WALL, SEE PLANS
STONE TYPE 2: FULL VENEER
PRECAST CONCRETE MARKER
WALL
LS503
TYP
FREE-DRAINING AGGREGATE/
GRANULAR
DRAINAGE BACKFILL
3/8" MORTAR JOINT
DECORATIVE AGGREGATE FLOWER STRIP
THICKENED-EDGE CONCRETE PAVEMENT
DAMP PROOFING HOLD DOWN 3" BELOW
FINISH GRADE; EXTRND DAMP
PROOFING DOWN TO TOP OF FOOTING
PRE-CAST CONCRETE MARKER
WALL
TYPE 1 HORIZONTAL CELL VENT.
SPACED BETWEEN NICHE/NICHE &
NICHE/VENEER JUNCTION
3/8" SEALANT W/BACKER ROD
STONE TYPE 1: BASE STONE;
MORTARED SOLID IN PLACE
1'- 6"
SEALANT
CONTINUOUS TERMINATION BAR
THRU-WALL DRIP EDGE FLASHING
7 5 /8"
TY
P.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
Office of
Design and Construction
Services U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
IRRIGATION:
WATER IN
MOTION, INC.
GEOTECHNICAL:
TERRACON
COST ESTIMATING:
OCMI
175 JAMES AVENUE NORTH
MINNEAPOLIS, MN 55405
952.229.1911
TIMOTHY MALOOLY
611 LUNKEN PARK DRIVE
CINCINNATI, OHIO 45226
513.612.9020
JEFF DUNLAP, PE
2100 NORTH GREENVILLE AVENUE
RICHARDSON, TEXAS 75082
469.431.0571
KYLE VEATER
BID DOCUMENTS
C :\U se rs
\rl ie be lt\
D oc um en ts \1
D N
C M em or ia l W al l_
R
_R
JL
ie be lt4
8.
rv t
-0
2-
:1
6:
PM
MEMORIAL WALL - SECTIONS DAYTON NATIONAL CEMETERY
GRAVESITE EXPANSION
4400 W THIRD ST, DAYTON, OH 45428
810CM3033
DECEMBER 5, 2025 JD RJL18125
LS301
3/4" = 1'-0"2 MARKER WALL SECTION - TYP.
3/4" = 1'-0"1 MEMORIAL WALL COLUMN SECTION - TYP.
1 1/2" = 1'-0"3 MARKER WALL CAP SETTING SECTION DETAIL, TYP.
3" = 1'-0"4 STONE TYPE 1 AT STEM WALL BASE
Revisions: Date:
LS302
STONE TYPE 1: CAP
STONE TYPE 1:
FULL VENEER
AIR GAP
LS502
SIM.
LS502
SIM.
LS503
T.O.W.
SEE 1/LS102
T.M.L.
SEE 1/LS102
VA
RI
ES
CAST-IN-PLACE CONCRETE
STEM WALL
STAINLESS STEEL
MASONRY TIES, TYP.
LS302
STONE TYPE 1: CAP
LS503
LS502
SIM.
LS503
T.O.W.
SEE 1/LS102
T.M.L.
SEE 1/LS102
T.S.W.
SEE 1/LS102
STONE TYPE 1:
FULL VENEER
AIR GAP
CAST-IN-PLACE CONCRETE
STEM WALL
STAINLESS STEEL
MASONRY TIES, TYP.
LS302
AIR GAP
3' HIGH ORNAMENTAL
FENCE. SEE 5/LS302
LS502
SIM.
T.O.W.
SEE 1/LS102
T.M.L.
SEE 1/LS102
STONE TYPE 1: FULL VENEER
STONE TYPE 1: CAP
CAST-IN-PLACE CONCRETE
STEM WALL
STAINLESS STEEL
MASONRY TIES, TYP.
LS506
LS503
LS506
T.O.W.
SEE 1/LS102
T.M.L.
SEE 1/LS102
T.S.W.
SEE 1/LS102
AIR GAP
ORNAMENTAL
FENCING. SEE 4/LS302
STONE TYPE 1: FULL VENEER
STONE TYPE 1: CAP
CAST-IN-PLACE CONCRETE
STEM WALL
STAINLESS STEEL
MASONRY TIES, TYP.
ORNAMENTAL
FENCING. SEE
1/CS503
NOTE:
SEE 2/CS503 FOR PEDESTRIAN
GATE AND 3/CS VEHICULAR GATE
ESCUTCHEON
PLATE COVER
FILL 4-14" DIA. HOLE WITH NON-SHRINK GROUT,
ENSURING 3/8" SPACING FROM SQ POST ON ALL
SIDES
STONE TYPE 1: CAPBASE PLATE POST & BOLTS CONNECTION
PER MANUFACTURER; BASIS OF DESIGN:
AMERISTAR BASE PLATE POST
STONE TYPE 1: FULL
VENEER, TYP.
WALL POSTS, REINFORCED WITH INTERNAL RIB
STAINLESS STEEL ANCHOR
SET IN PLACE WITH EPOXY
T.O.W.
SEE 1/LS1021"
7"
5/8" 5/8"
STONE TYPE 1: FULL VENEER
STONE TYPE 1: CAP
AIR GAP
T.O.W.
SEE 1/LS102
T.M.L.
SEE 1/LS102
T.S.W.
SEE 1/LS102
LS503
CAST-IN-PLACE CONCRETE
STEM WALL
STAINLESS STEEL
MASONRY TIES, TYP.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
Office of
Design and Construction
Services U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
IRRIGATION:
WATER IN
MOTION, INC.
GEOTECHNICAL:
TERRACON
COST ESTIMATING:
OCMI
175 JAMES AVENUE NORTH
MINNEAPOLIS, MN 55405
952.229.1911
TIMOTHY MALOOLY
611 LUNKEN PARK DRIVE
CINCINNATI, OHIO 45226
513.612.9020
JEFF DUNLAP, PE
2100 NORTH GREENVILLE AVENUE
RICHARDSON, TEXAS 75082
469.431.0571
KYLE VEATER
BID DOCUMENTS
C :\U se rs
\rl ie be lt\
D oc um en ts \1
D N
C E nt ry
W al l_ R
_R
JL
ie be lt4
8.
rv t
-0 2-
:2 4:
PM
ENTRY WALL - SECTIONS DAYTON NATIONAL CEMETERY
GRAVESITE EXPANSION
4400 W THIRD ST, DAYTON, OH 45428
810CM3033
DECEMBER 5, 2025 JAF RJL18125
LS302
3/4" = 1'-0"1 ENTRY WALL COLUMN SECTION, TYP.
3/4" = 1'-0"2 COLUMN TO STEM WALL CROSS-SECTION, TYP.
3/4" = 1'-0"4 ORNAMENTAL FENCE WALL SECTION ELEVATION, TYP.
3/4" = 1'-0"5 ORNAMENTAL FENCE WALL CROSS-SECTION, TYP.
3" = 1'-0"6 ENLARGEMENT ORNAMENTAL FENCE CAP - TYP.
3/4" = 1'-0"3 ENTRY WALL SECTION ELEVATION - TYP.
Q
CAST-IN-PLACE CONCRETE
STEM WALL
CAST-IN-PLACE CONCRETE MASONRY
LEDGE
CAST-IN-PLACE CONCRETE
COLUMN STEM WALL
CAST-IN-PLACE CONCRETE STEM WALL WING
WALL
STONE TYPE 1: FULL VENEER
STONE TYPE 2: ASHLAR
LIGHT DUTY CONCRETE PAVEMENT
RECESSED STONE COURSING (BELOW)
STONE TYPE 1: BANDING (BEYOND)
DECORATIVE AGGREGATE FLOWER STRIP,
CONTINUOUS
1/2
6" 1'-
3 1 /2"
6" 5 1 /4"
5" 1'-5" 5"
1/2
6" 1'-
3 1 /2"
6"5 1 /4"
6" 1'-7 1/2" 8" 6"
5 1/4" 5 1/4"3/8" TYP.
2'-3"
2'- 3 1
/2"
3'-3 1/2"
2'- 3 1
/2"
D
LIGHT DUTY CONCRETE
PAVEMENT
DECORATIVE AGGREGATE FLOWER
STRIP, CONTINUOUS
STONE TYPE 1: FULL VENEER
CAST-IN-PLACE CONCRETE
MASONRY LEDGE
CAST-IN-PLACE CONCRETE STEM
WALL
CAST-IN-PLACE CONCRETE
COLUMN STEM WALL
STONE TYPE 2: ASHLAR
STONE TYPE 1: BANDING (BEYOND)
RECESSED STONE COURSING
(BELOW)
6" 2'-3 1/2" 6" 1/2"
5 1/4"
6" 2'-
3 1 /2"
6" 1/2
5 1 /4"
5" 1'-5" 5"
3/8"TYP.
5" 1'-
5" 5"
1/2
6" 8 1
/2"
8 1/2" 6" 1/2"
3'- 3 1
/2"
3'-3 1/2"
D
STONE TYPE 1: BANDING (BEYOND)
STONE TYPE 2: ASHLAR
STONE TYPE 1: FULL VENEER
DECORATIVE AGGREGATE FLOWER
STRIP, CONTINUOUS
CAST-IN-PLACE CONCRETE STEM
WALL
CAST-IN-PLACE CONCRETE
COLUMN STEM WALL
CAST-IN-PLACE CONCRETE
MASONRY LEDGE
RECESSED STONE
COURSING (BELOW)
LIGHT DUTY CONCRETE
PAVEMENT
5" 1'-11 1/2" 5"
1/2
6" 2'-
3 1 /2"
6"5 1 /4"
1/2" 6" 2'-3 1/2" 6"
5 1/4"3/8" TYP.
5" 1'-
5" 5"
8 1 /2"
2"
3'-3 1/2"
3'- 3 1
/2"
B
STONE TYPE 1: FULL
VENEER
STONE TYPE 2: ASHLAR
STONE TYPE 1: BANDING
(BEYOND)
RECESSED STONE
COURSING (BELOW)
CAST-IN-PLACE CONCRETE
MASONRY LEDGE
CAST-IN-PLACE CONCRETE
STEM WALL
CAST-IN-PLACE CONCRETE
COLUMN STEM WALL
DECORATIVE AGGROGATE
FLOWER STRIP
LIGHT DUTY CONCRETE
PAVEMENT
5" 1'-
5" 5"
6" 8 1
/2" 1'-
5" 2"
6"
5 1 /4"
1/2" 6" 2'-3 1/2" 6" 1/2"
5 1 /4"
3/8" TYP.
3'- 3 1
/2"
3'-3 1/2" 2'-
3"
B
RECESSED STONE
COURSING (BELOW)
STONE TYPE 1: BANDING (BEYOND)
STONE TYPE 2: ASHLAR
STONE TYPE 1: FULL VENEER
CAST-IN-PLACE CONCRETE
COLUMN STEM WALL
CAST-IN-PLACE CONCRETE STEM
WALL
CAST-IN-PLACE CONCRETE
MASONRY LEDGE
DECORATIVE AGGREGATE
FLOWER STRIP
LIGHT WEIGHT CONCRETE
PAVEMENT
STONE TYPE 1: BANDING (BEYOND)
STONE TYPE 2: ASHLAR
6" 2'-3 1/2" 6" 1/2"
5 1/4" 2" 1'-11 1/2" 2"
5" 1'-
5" 5"
6" 2'-
3 1 /2"
6" 1/2
5 1 /4"
2" 1'-
5" 8 1
/2"
5" 1'-11 1/2" 5"
3/8" TYP.
3'- 3 1
/2"
3'-3 1/2"
P
STONE TYPE 1: FULL VENEER
STONE TYPE 2: ASHLAR
CAST-IN-PLACE CONCRETE
COLUMN STEM WALL
CAST-IN-PLACE CONCRETE STEM
WALL; SEE
DECORATIVE AGGREGATE
FLOWER STRIP
RECESSED STONE COURSING
(BELOW)
CAST-IN-PLACE CONCRETE MASONRY
LEDGE; SEE
CAST-INI-PLACE LIGHT DUTY
CONCRETE PAVEMENT
5" 2'-11" 5"6"
6" 6" 3'-4" 6" 6"
5 1/4" 5 1/4"
6" 1'-
3 1 /2"
6" 1/2
5 1 /4"
3/8" TYP.
2'- 3 1
/2"
5'-4"
3'-9"
6"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
Office of
Design and Construction
Services U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
IRRIGATION:
WATER IN
MOTION, INC.
GEOTECHNICAL:
TERRACON
COST ESTIMATING:
OCMI
175 JAMES AVENUE NORTH
MINNEAPOLIS, MN 55405
952.229.1911
TIMOTHY MALOOLY
611 LUNKEN PARK DRIVE
CINCINNATI, OHIO 45226
513.612.9020
JEFF DUNLAP, PE
2100 NORTH GREENVILLE AVENUE
RICHARDSON, TEXAS 75082
469.431.0571
KYLE VEATER
BID DOCUMENTS
C :\U se rs
\rl ie be lt\
D oc um en ts \1
D N
C C ol um ba riu m _R
JL
ie be lt4
8.
rv t
-0 2-
:1 9:
PM
COLUMBARIUM - COLUMN
ENLARGEMENT DETAILS
DAYTON NATIONAL CEMETERY
GRAVESITE EXPANSION
4400 W THIRD ST, DAYTON, OH 45428
810CM3033
DECEMBER 5, 2025 JAF RJL18125
LS400
1 1/2" = 1'-0"1a COLUMBARIUM PERIMETER WALL 1 - END COLUMN ENLARGEMENT 1 1/2" = 1'-0"2a COLUMBARIUM PERIMITER WALL 1/2 - OUTSIDE CORNER COLUMN ENLARGEMENT, TYP.
1 1/2" = 1'-0"3a COLUMBARIUM PERIMITER WALL 2/3 & 3/4 - INSIDE CORNER COLUMN ENLARGEMENT, TYP.
1 1/2" = 1'-0"5 COLUMBARIUM PERIMITER WALL 3 - CENTER COLUMN ENLARGEMENT
1 1/2" = 1'-0"4a COLUMBARIUM PERIMITER WALL 2/3 & 3/4 - OUTSIDE CORNER COLUMN ENLARGEMENT, TYP.
1 1/2" = 1'-0"6 COLUMBARIUM DOUBLE WALL - END COLUMN ENLARGEMENT, TYP.
DETAIL 2b IS MIRRORED CONDITION OF DETAIL 2a ABOVE2bDETAIL 1b IS MIRRORED
CONDITION OF DETAIL 1a ABOVE1b DETAIL 3b IS MIRRORED CONDITION OF DETAIL 3a ABOVE3b
DETAIL 4b IS MIRRORED CONDITION OF DETAIL 4a ABOVE4b
BB
STONE TYPE 1: BANDING (BEYOND)
STONE TYPE 2: ASHLAR
STONE TYPE 1: FULL VENEER
DECORATIVE AGGREGATE FLOWER
STRIP, CONTINUOUS
CAST-IN-PLACE CONCRETE STEM
WALL
CAST-IN-PLACE CONCRETE
COLUMN STEM WALL
CAST-IN-PLACE CONCRETE
MASONRY LEDGE
RECESSED STONE
COURSING (BELOW)
LIGHT DUTY CONCRETE
PAVEMENT
PRECAST CONCRETE
MARKER WALL UNIT
6" 1'-3 1/2" 6"
5 1/4"
6" 2'-
3 1 /2"
6"
5 1 /4"
5 1 /4"
8" 1'-
2 1 /4"
5"
1'- 5 1
/4"
5 1 /4"
7 1 /4"
5 1 /2"
3/8" TYP.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
Office of
Design and Construction
Services U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
IRRIGATION:
WATER IN
MOTION, INC.
GEOTECHNICAL:
TERRACON
COST ESTIMATING:
OCMI
175 JAMES AVENUE NORTH
MINNEAPOLIS, MN 55405
952.229.1911
TIMOTHY MALOOLY
611 LUNKEN PARK DRIVE
CINCINNATI, OHIO 45226
513.612.9020
JEFF DUNLAP, PE
2100 NORTH GREENVILLE AVENUE
RICHARDSON, TEXAS 75082
469.431.0571
KYLE VEATER
BID DOCUMENTS
C :\U se rs
\rl ie be lt\
D oc um en ts \1
D N
C M em or ia l W al l_
R
_R
JL
ie be lt4
8.
rv t
-0
2-
:1
6:
PM
MEMORIAL WALL - COLUMN
ENLARGEMENT DETAILS
DAYTON NATIONAL CEMETERY
GRAVESITE EXPANSION
4400 W THIRD ST, DAYTON, OH 45428
810CM3033
DECEMBER 5, 2025 JD RJL18125
LS401
1 1/2" = 1'-0"1 MEMORIAL WALL END COLUMN ENLARGED VIEW
1 5
LS302
A
RECESSED STONE
COURSING (BELOW)
STONE TYPE 1: FULL VENEER
CAST-IN-PLACE CONCRETE
COLUMN STEM WALL
CAST-IN-PLACE CONCRETE
STEM WALL
CAST-IN-PLACE CONCRETE
MASONRY LEDGE
LIGHT DUTY CONCRETE
PAVEMENT
6" 1'-3 1/2"
5 1/4"
6" 2'-
7 1 /2"
6" 5 1 /4"
5 1 /4"
3'- 7 1
/2"
5 1 /4"
6" 1'-
9" 6"
5 1 /4"
5 1 /4"
5 1 /4"
2'- 9"
3/8" TYP.
B
STONE TYPE 1: FULL VENEER
STONE TYPE 1: FULL VENEER
CAST-IN-PLACE
CONCRETE STEM WALL
CAST-IN-PLACE CONCRETE
COLUMN STEM WALL
CAST-IN-PLACE CONCRETE
MASONRY LEDGE
RECESSED STONE
COURSING (BELOW)
LIGHT DUTY CONCRETE
PAVEMENT
6" 2'-
7 1 /2"
6"
5 1 /4"
5 1 /4"
3'- 7 1
/2"
6" 1'-3 1/2" 6"
2'-3 1/2"
6" 1'-
9" 6"
5 1 /4"
5 1 /4"
2'- 9"
3/8" TYP.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
Office of
Design and Construction
Services U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
IRRIGATION:
WATER IN
MOTION, INC.
GEOTECHNICAL:
TERRACON
COST ESTIMATING:
OCMI
175 JAMES AVENUE NORTH
MINNEAPOLIS, MN 55405
952.229.1911
TIMOTHY MALOOLY
611 LUNKEN PARK DRIVE
CINCINNATI, OHIO 45226
513.612.9020
JEFF DUNLAP, PE
2100 NORTH GREENVILLE AVENUE
RICHARDSON, TEXAS 75082
469.431.0571
KYLE VEATER
BID DOCUMENTS
C :\U se rs
\rl ie be lt\
D oc um en ts \1
D N
C E nt ry
W al l_ R
_R
JL
ie be lt4
8.
rv t
-0 2-
:2 4:
PM
ENTRY WALL - COLUMN
ENLARGEMENT DETAILS
DAYTON NATIONAL CEMETERY
GRAVESITE EXPANSION
4400 W THIRD ST, DAYTON, OH 45428
810CM3033
12/05/25 Checker Author18125
LS402
1 1/2" = 1'-0"1 ENTRY WALL - END COLUMN ENLARGEMENT, TYP.
1 1/2" = 1'-0"2 ENTRY WALL - CENTER COLUMN ENLARGEMENT, TYP.
SIDE - ELEVATION FRONT - ELEVATION
PRE-CAST COLUMBARIUM NICHE - PROVIDE LIFTING INSERTS,
RE-INFORCING, AND WELD PLATES PER TECHNICAL SPECIFICATIONS
INSTALL ANCHOR BOLTS, WASHERS & EXPANSION SHIELDS PER SUBMITTAL REQUIREMENTS; FIELD INSTALL & FILL WITH
SEALANT FLUSH WITH ADJACENT CONCRETE, TYP.
NICHE COVERS:
PRE-DRILLED HOLES
FOR ATTACHMENT
ROSETTE (TYP.)
WELD PLATE, SEE 2/LS500
7'
0"
1'
3"
10 1/2"1 1/2"
1/
2"
1 1/2"
1/
2"
1' - 8"
1'
1/
2"
1'
3"
1/ 2"
2"
2" 7'
0"
1' - 10"
1/
2"
10' 1-1/2" (5HT X 10W) / 9' 1-1/2" (5HT X 9W) / 7' 1-1/2" (5HT X 7W) / 6' 1-1/2" (5HT X 6W) / 5' 1-1/2" (5HT X 5W)
WELD PLATE, SEE
DETAIL (TYP.)
PRE-CAST CONCRETE COLUMBARIUM UNITS - DELEGATED
DESIGN REQUIREMENTS:
1. THE CONTRACTOR SHALL PROVIDE STRUCTURAL
DESIGN OF THE PRE-CAST CONCRETE
COLUMBARIUM UNITS. STRUCTURAL DESIGN SHALL
BE SUBMITTED BY THE CONTRACTOR TO THE
CONTRACTING OFFICER'S REPRESENTATIVE (COR)
AND ENGINEER OF RECORD (EOR) AS A DELEGATED
DESIGN SUBMITTAL. DELEGATED SUBMITTALS SHALL
INCLUDE DRAWINGS AND CALCULATIONS THAT HAVE
BEEN STAMPED AND SIGNED BY AN ENGINEER
APPROPRIATELY LICENSED IN THE STATE OF
CONSTRUCTION,
2. THE PURPOSE OF THE EOR'S REVIEW SHALL BE
DETERMINING THE DRAWINGS AND CALCULATIONS
HAVE BEEN PROPERLY SEALED, THAT THE LOAD
CRITERIA IS IN GENERAL CONFORMANCE WITH THE
CONTRACT DOCUMENTS AND THE REFERENCED
BUILDING CODE, AND THAT THE CONNECTIONS TO
THE PRIMARY STRUCTURE ARE APPROPRIATE FOR
THE STRUCTURE'S DESIGNED CAPABILITIES.
INCLUDED IN THE STRUCTURAL CALCULATIONS AND
DESIGN AT MINIMUM SHALL BE:
A. DESIGN OF PRE-CAST CONCRETE COLUMBARIUM
UNITS.
B. CONNECTION OF THE PRE-CAST UNITS TO
STRUCTURAL FOUNDATIONS, BOTTOM AND TOP.
C. CONNECTION OF PRE-CAST UNITS BACK TO BACK
AND END TO END.
D. CONNECTION OF PRE-CAST UNITS TO NATURAL
STONE CAPS.
REFER TO SPECIFICATION 03 48 24 - PRE-CAST CONCRETE
COLUMBARIUM UNITS AND S001 FOR
ADDITIONAL INFORMATION.
OVERALL COVER
11 1/4"
INSIDE NICHE FACE
10 1/2"
O
VE
R
AL
L C
O
VE
R 1'
3/ 4"
IN
SI
D E
N
IC
H E
FA
C
E 1'
3"
1 1/4"
1/
4"
3/4" THICK BLANK
NICHE COVER PLATE.
3/8" DIA. PRE-DRILLED HOLE
TO ACCEPT STAINLESS
STEEL BOLTS AND
ROSETTES, (4) TYPICAL DIA.
COORDINATE SIZE OF HOLE
WITH 3/16" ROSETTE
FASTENERS
EQ
EQ
EQ EQ
IN
SI
D E
N
IC
H E
BA
C
K 1'
1/ 2"
INSIDE NICHE FACE
10"
ALL EDGES OF THE FRONT,
BACK, AND CORNERS
SHALL BE SMOOTH SAWN
AND FINISHED WITH A
CLEAN 1/8" ARIS (EASED
EDGE)
NOTE:
NICHE COVER TO BE PROVIDED BY GOVERNMENT & INSTALLED BY CONTRACTOR
CL
C L
1" DIA. ROSETTE W/ WASHER
TAMPER-PROOF
SCREW
WASHER
CLIP ANGLE ASSEMBLY
WASHER
WASHER &
LOCKWASHER
BOLT & HEX NUT, 1/4"-20 X
2 1/2" LONG
SPRING CLIP
SPRING CLIPNOTE: ALL HARDWARE TO
BE STAINLESS STEEL
1/4" DIA. HOLE, CAST IN
PLACE - HOLE NOT TO
EXTEND THRU NICHE
WALL
1/4" x 1 1/2" EXPANSION
BOLT, LOCK WASHER & HEX
NUT
1/4" DIA. HOLE, CAST IN
PLACE, TYP.
PLASTIC SHIMS, TYP.
1/4" x 1 3/4" EXPANSION BOLT, LOCK WASHER & HEX NUT
ALL EXPOSED NICHE FRONTS
SHALL BE A SMOOTH SURFACE
NICHE COVERS W/ PRE-DRILLED
3/8" DIA. HOLES TO ACCEPT
ROSETTE & BOLT
3/4" DIA. WASHER, TYP.
LS500
9 TYP
LS500
8 TYP
3/ 8"
3/ 8"
3/ 4"
3/ 4"
NOTE: ALL HARDWARE TO
BE STAINLESS STEEL
1.
A.
B.
C.
2.
NOTES:
CONTRACTOR IS RESPONSIBLE FOR PROVIDING
STRUCTURAL CALCULATIONS AND DESIGN OF
THE EMBEDDS AS A DELIGATED DESIGN ITEM.
DESIGN AND CALCULATIONS SHALL AT MINIMUM
PROVIDE:
CONNECTIONS TO CAST-IN-PLACE
FOUNDATIONS, BOTTOM AND TOP.
CONNECTIONS OF PRECAST UNITS, BACK TO
BACK AND END TO END.
CONNECTIONS TO NATURAL STONE CAP
REFER TO SPECIFICATIONS FOR ADDITIONAL
REQUIREMENTS
STAINLESS STEEL
EMBEDDED WELD
PLATE, TYP.
STAINLESS STEEL WELD PLATE
PRECAST COLUMBARIUM UNIT PRECAST CONCRETE
COLUMBARIUM UNIT, TYP.
STAINLESS STEEL
EMBEDDED WELD
PLATE, TYP.
STAINLESS STEEL WELD PLATE
END COLUMN, SEE PLANS FOR
ADDITIONAL INFORMATION, TYP.
PRECAST CONCRETE
COLUMBARIUM UNIT, TYP.
STAINLESS STEEL WELD PLATE, RECESSED 1/4"
FROM TOP OF PRECAST UNIT
END COLUMN / STEM WALL,
SEE PLANS FOR ADDITIONAL
INFORMATION, TYP.
STAINLESS STEEL EMBEDDED
WELD PLATE W/ NELSON STUD,
TYP.
NATURAL STONE CAP
PRECAST COLUMBARIUM UNIT,
TYP.
STAINLESS STEEL WELD PLATE, RECESSED 1/4"
STAINLESS STEEL EMBEDDED
WELD PLATE W/ NELSON STUD,
TYP.
NATURAL STONE CAP
PLAN VIEW:
BACK TO BACK PRECAST
COLUMBARIUM
PLAN VIEW:
BACK TO BACK PRECAST
COLUMBARIUM TO END COLUMN
SECTION A-A' VIEW:
END COLUMN / STEM WALL CONNECTION
SECTION B-B' VIEW:
DOUBLE SIDED PRECAST
COLUMBARIUM CONNECTION
VARIES
VA
R
IE
S
VA
R
IE
S
VARIES
VARIES
VA
R
IE
S
VARIES
VARIES
VA
RI
ES
PRECAST COLUMBARIUM UNIT
STAINLESS STEEL WELD PLATE
STAINLESS STEEL
EMBEDDED WELD
PLATE, TYP.
VA
RI
ES
VARIES
STAINLESS STEEL
EMBEDDED WELD
PLATE, TYP.
PRECAST COLUMBARIUM UNIT
PLAN VIEW:
SINGLE SIDED PRECAST COLUMBARIUM UNIT
TO END COLUMN
PLAN VIEW:
SINGLE SIDED PRECAST
COLUMBARIUM
THREADED SPRING CLIP TO RECEIVE
ROSETTE BOLT.
5/16" x 3/4" SLOTS
SIDE VIEW FRONT VIEW PLAN VIEW
3/32" THICK STAMPED
ANGLE BRACKET W/ (2)
SLOTS
1/
2"
1 1/4"
1/ 2"
3/4" 3/4"
7/1 6" 21
/12 8"
9/6 4"
3/3 2"
R 3/6
4"1/2"
EQ
EQ
THREADED SPRING CLIP
SIDE VIEWPLAN VIEW
NOTE: ALL HARDWARE TO
BE STAINLESS STEEL
STAINLESS STEEL
ROSETTE FASTENER,
TYP.
NICHE COVER
PLATE, TYP. STAINLESS STEEL
NICHE COVER
MOUNTING
BRACKETS, TYP.
3/4"
3/4"
10 1/2"
3/4"
3/4"
1' - 0"
1'
3/
4" 3/
4" 3/
4" 1'
1/ 4"
3/ 4"
3/ 4"
LS500
9 TYP
LS500
TYP
PRE-DRILLED WITH 7/16"
DIAMETER HOLE TO ACCEPT
STAINLESS STEEL BOLTS
AND STAINLESS STEEL
ROSETTES (4) TYP. VERIFY
PRIOR TO INSTALLATION
1/2" DIAMETER CAST
IN PLACE HOLE
PRECAST
COLUMBARIUM
NICHE UNIT, TYP.
1 1/4"
1 1 /4"
TYP. CONDITION AT INTERMEDIATE
SHELVES OF PRE-CAST UNIT
STAINLESS STEEL 3/8" DIAMETER X 3" THREADED
ROD, LOCK WASHER & HEX NUTS & PLASTIC SHIMS
STAINLESS STEEL ROSETTE AND BOLT,
TYP.
1/2" DIAMETER CAST IN PLACE HOLE,
TYP.
STAINLESS STEEL ROSETTE AND
BOLT, SEE DETAIL
STAINLESS STEEL NICHE COVER
MOUNTING BRACKET, SEE DETAIL
NICHE COVERS W/ PREDRILLED 7/16"
DIA. HOLES TO ACCEPT STAINLESS
STEEL ROSETTE & BOLT - COVERS
ARE 11 1/4" WIDTH x 1' 3 3/4" HEIGHT x
3/4" THICK
7/8" DIAMETER, 1/16" THICK CLEAR
WASHER, TYP. (2) FOR EACH
STAINLESS STEEL ROSETTE
STAINLESS STEEL ROSETTE AND BOLT
(TYP.) THROUGH 7/16" DIAMETER PRE-
DRILLED HOLE
ALL EXPOSED CONCRETE (NICHE
FRONTS) SHALL BE GROUND OR
PATCHED SMOOTH; APPLY 2 COATS
SPECIFIED HIGH BOND SEALER SUPER
COLOR COATING
1/2" DIAMETER CAST IN PLACE HOLE
PLASTIC SHIMS, TYP.
STAINLESS STEEL 1/4" x 1
3/4" EXPANSION BOLT,
LOCK WASHER & HEX
NUT, TYP.
FACE BACK
MATCH EXISTING ROSETTE
(VA STANDARD); PROVIDE PRODUCT LITERATURE &
SAMPLE FOR APPROVAL.
1/8" DIAMETER
1/16" NEOPRENE WASHER
MATCH EXISTING 3/16" x 1 1/2"
LENGTH TAMPER-PROOF SPANNER
HEAD BOLT
FRONT ELEVATION
SECTION
8 - PETAL ROSETTE
D
IA
1"
NOTES:
1.ROSETTES AND ASSOCIATED HARDWARE TO BE
PROVIDED AND INSTALLED BY THE CONTRACTOR.
ROSETTES AND SPANNER HEAD BOLT AND NUT TO BE
VA CONFIRMED
2.ALL HARDWARE TO BE STAINLESS STEEL
3/8" SEALANT
BACKER
ROD
PRECAST NICHE UNIT
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
Office of
Design and Construction
Services U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
IRRIGATION:
WATER IN
MOTION, INC.
GEOTECHNICAL:
TERRACON
COST ESTIMATING:
OCMI
175 JAMES AVENUE NORTH
MINNEAPOLIS, MN 55405
952.229.1911
TIMOTHY MALOOLY
611 LUNKEN PARK DRIVE
CINCINNATI, OHIO 45226
513.612.9020
JEFF DUNLAP, PE
2100 NORTH GREENVILLE AVENUE
RICHARDSON, TEXAS 75082
469.431.0571
KYLE VEATER
BID DOCUMENTS
C :\U se rs
\rl ie be lt\
D oc um en ts \1
D N
C C ol um ba riu m _R
JL
ie be lt4
8.
rv t
-0 2-
:1 9:
PM
COLUMBARIUM - PRECAST DETAILS DAYTON NATIONAL CEMETERY
GRAVESITE EXPANSION
4400 W THIRD ST, DAYTON, OH 45428
810CM3033
DECEMBER 5, 2025 JAF RJL18125
LS500
3/4" = 1'-0"1 PRECAST COLUMBARIUM NICHE UNIT - 5 HIGH
3" = 1'-0"4 NICHE COVER PLATE (VA PROVIDED) / (CONTRACTOR INSTALLED)
12" = 1'-0"7 COLUMBARIUM FASTENER ASSEMBLY - ISOMETRIC
6" = 1'-0"5 NICHE COVER ATTACHMENT SECTION
1" = 1'-0"2 PRECAST COLUMBARIUM UNIT WELD PLATE DETAILS
12" = 1'-0"9 NICHE COVER MOUNTING BRACKET
3" = 1'-0"3 NICHE COVER PLATE ATTACHMENT1
12" = 1'-0"8 ROSETTE FASTENER DETAIL
6" = 1'-0"6 COLUMBARIUM NICHE JOINT DETAIL
3/8" AT BOARDERS
1/4
MEMORIAL WALL PLAQUE MARKER, SEE
2/LS501
MEMORIAL WALL STAINLESS STEEL
ROSETTE PLATE, SEE 3/LS501
FACE OF MEMORIAL WALL BOARDER
PLAQUES
RECESSED PORTION OF
MEMORIAL WALL BOARDER
SPRING PLATE WITH TAMPER-
PROOF SCREW
ROSETTE, SEE 8/LS500
CENTER POST TO RECEIVE TAMPER-
PROOF ROSETTE PIN
MEMORIAL WALL RIGHT EDGE
ATTACHMENT DETAIL
NOTE:
RIGHT SIDE EDGE IS SHOWN,
LEFT SIDE EDGE IS A MIRROR IMAGE
OVERLAP BETWEEN ROSETTE AND FACE
OF BOARDER PLAQUES
OVERLAP BETWEEN ROSETTE AND
FACE OF MEMORIAL WALL MARKER
PLAQUE
13/16" 1/2" 7/16"
5/16" 3/8" 11/16"
/16
5/8
1 5
/16
2 5 /8"1/8"
TYPE 302 ROSETTE PLATE
HORIZONTAL SLOT FOR CENTER POST SECURED WITH
WASHER AND SCREW AT BACK TO RECEIVE TAMPER-PROOF
ROSETTE PIN
VERTICAL SLOT FOR TAMPER-PROOF SCREW TO SECURE
SPRING PLATE WITH ROSETTE PLATE TO DROP-IN ANCHOR IN
PRECAST MEMORIAL WALL UNIT
RIGHT EDGE ROSETTE PLATE
CL
CL
TYP.
3/4"
TYP.
1 1/2"
TYP.
3/4"
MORTARED IN PLACE BOARDER MEMORIAL WALL PLAQUE
LONG CENTER POST w/(2) CHANNELS TO ALLOW HORIZONTAL
MOVEMENT ONLY IN ROSETTE PLATE SLOT. THREADED THROUGH TO
RECEIVE TAMPER PROOF ROSETTE PIN AND MOUNTING BOLT, TYP.
TAMPER-PROOF ROSETTE PIN, TYP.
TYPE 302 ROSETTE PLATE
SPRING PLATE, TYP.
PLASTIC WASHER, TYP.
TYPE 302 ROSETTE PLATE
MEMORIAL WALL PLAQUE, SEE 8/LS501
ROSETTE w/NEOPRENE WASHER
SHORT CENTER POST w/(2) CHANNELS TO ALLOW HORIZONTAL
MOVEMENT ONLY IN ROSETTE PLATE SLOT. THREADED THROUGH TO
RECEIVE TAMPER PROOF ROSETTE PIN AND MOUNTING BOLT, TYP.
TAMPER-PROOF ANCHORING SCREW
CONTRACTOR TO FIELD DRILL CONCRETE WITH A 3/8" DRILL BIT
TO 1-1/8" DEEP TO RECEIVE THE TAMPER-PROOF SCREW WITH
THREADED INSERT
TAMPER-PROOF POST SCREW, TYP.
CL
CL
CL
3/4" THICK BLANK MEMORIAL WALL MARKER
PROVIDED BY THE VA NCA; INSTALLED BY
THE CONTRACTOR
7 3 /4"
11 1/4"
VA SUPPLIED PLAQUES FIELD CUT AND MORTARED IN PLACE MEMORIAL WALL BORDER PLAQUES
3 3/4" 11 1/4"
3 3/4"
3 1 /2"
3 1 /2"
7 3 /4"
CONTRACTOR TO FIELD DRILL CONCRETE WITH A
3/8" DRILL BIT TO 1-1/8" TO RECIEVE THE SCREW
w/THREADED INSERT
TYPE 302 ROSETTE PLATE
SPRING PLATE
TAMPER-PROOF SCREW
TAMPER-PROOF ROSETTE PIN
ROSETTE w/NEOPRENE WASHER TO MATCH
EXISTING COLUMBARIUM UNIT ROSETTE
CENTER POST w/(2) CHANNELS TO ALLOW HORIZONTAL
MOVEMENT ONLY IN ROSETTE PLATE SLOT. THREADED INTERIOR
TO RECEIVE TAMPER-PROOF ROSETTE PIN
POST SCREW AND WASHER
FACE OF MEMORIAL WALL
BOARDER PLAQUES
ROSETTE, SEE 8/LS500
OVERLAP BETWEEN ROSETTE AND MEMORIAL
WALL BOARDER PLAQUES
CENTER POST TO RECEIVE TAMPER-
PROOF ROSETTE PIN
OVERLAP BETWEEN ROSETTE
AND MEMORIAL WALL MARKER
PLAQUE
RECESSED PORTION OF
MEMORIAL WALL BOARDER
PLAQUES
EDGE OF MEMORIAL WALL
MARKER PLAQUE
ROSETTE PLATE
SPRING PLATE WITH TAMPER-
PROOF SCREW 1/4" TYP.
AT
E
DG
ES
3/8
MEMORIAL WALL TOP EDGE
ATTACHMENT
3 1/4"
3/4
3/4 " 1 1
/2"
CL 1/8
3/8" 1 1/4"
TYPE 302 ROSETTE PLATE
HORIZONTAL SLOT FOR CENTER POST SECURED WITH
WASHER AND SCREW AT BACK TO RECEIVE TAMPER-
PROOF ROSETTE PIN
VERTICAL SLOT FOR TAMPER-PROOF SCREW TO
SECURE SPRING PLATE WITH ROSETTE PLATE TO
DROP-IN ANCHOR IN PRECAST MEMORIAL WALL UNIT
TOP EDGE ROSETTE PLATE
FACE OF MEMORIAL WALL
BOARDER PLAQUES
ROSETTE, SEE 8/LS500
OVERLAP BETWEEN ROSETTE AND
BOARDER PLAQUES
CENTER POST TO RECEIVE TAMPER-
PROOF ROSETTE PIN
OVERLAP BETWEEN ROSETTE
AND MEMORIAL WALL MARKER
PLAQUE
RECESSED PORTION OF MEMORIAL
WALL BOARDER
EDGE OF MEMORIAL WALL
MARKER PLAQUE
ROSETTE PLATE
SPRING PLATE WITH TAMPER-
PROOF SCREW
MEMORIAL WALL BOTTOM EDGE
ATTACHMENT
1/4" TYP.
A T
BO
AR
DE
RS
3/8
3/8
3 1/4"
1" 1 1/8"
1 5 /16
1 1
1/1 6"1/8
1/8
1/2"
CL
TYPE 302 SS ROSETTE PLATE
HORIZONTAL SLOT FOR CENTER POST SECURED WITH
WASHER AND SCREW AT BACK TO RECEIVE TAMPER-
PROOF ROSETTE PIN
VERTICAL SLOT FOR TAMPER-PROOF SCREW TO SECURE
SPRING PLATE WITH ROSETTE PLATE TO DROP-IN ANCHOR IN
PRECAST MEMORIAL WALL UNIT
BOTTOM EDGE ROSETTE PLATE
21' 9-3/4" WIDTH
5'- 6"
H
EI
GH
T
8"
PRECAST MEMORIAL WALL - PROVIDE LIFTING
INSERTS,
RE-INFORCING, AND WELD PLATES PER
TECHNICAL SPECIFICATIONSWELD PLATE; SEE 5/LS501
SIDE - ELEVATION FRONT - ELEVATION
1.
A.
B.
C.
2.
NOTES:
CONTRACTOR IS RESPONSIBLE FOR PROVIDING STRUCTURAL CALCULATIONS AND DESIGN OF
THE EMBEDDS AS A DELIGATED DESIGN ITEM. DESIGN AND CALCULATIONS SHALL AT MINIMUM
PROVIDE:
CONNECTIONS TO CAST-IN-PLACE FOUNDATIONS, BOTTOM AND TOP.
CONNECTIONS OF PRECAST UNITS, BACK TO BACK AND END TO END.
CONNECTIONS TO NATURAL STONE CAP
REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS
EMBEDDED WELD
PLATE, TYP.
WELD PLATE
CAST-IN-PLACE STEM WALL
PRECAST CONCRETE
COLUMBARIUM UNIT, TYP.
EMBEDDED WELD
PLATE, TYP.
WELD PLATE
END COLUMN, SEE PLANS FOR
ADDITIONAL INFORMATION, TYP.
PRECAST
MEMORIAL WALL
WELD PLATE, RECESSED 1/4"
FROM TOP OF PRECAST MEMORIAL
WALL
END COLUMN/ STEM WALL,
SEE PLANS FOR ADDITIONAL
INFORMATION
EMBEDDED WELD PLATE
w/NELSON STUD, TYP.
NATURAL STONE CAP
PLAN VIEW:
BACK TO BACK PRECAST MEMORIAL WALL
TO STEM WALL
PLAN VIEW:
BACK TO BACK PRECAST MEMORIAL
WALL TO END COLUMN
SECTION VIEW:
END COLUMN / STEM WALL CONNECTION
VARIES
VA
R
IE
S
VARIES
PRECAST MEMORIAL WALL
VA
RI
ES
VARIES
VA
RI
ES
VARIES
CONTINUOUS SELF ADHESIVE EPDM
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
Office of
Design and Construction
Services U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
IRRIGATION:
WATER IN
MOTION, INC.
GEOTECHNICAL:
TERRACON
COST ESTIMATING:
OCMI
175 JAMES AVENUE NORTH
MINNEAPOLIS, MN 55405
952.229.1911
TIMOTHY MALOOLY
611 LUNKEN PARK DRIVE
CINCINNATI, OHIO 45226
513.612.9020
JEFF DUNLAP, PE
2100 NORTH GREENVILLE AVENUE
RICHARDSON, TEXAS 75082
469.431.0571
KYLE VEATER
BID DOCUMENTS
C :\U se rs
\rl ie be lt\
D oc um en ts \1
D N
C M em or ia l W al l_
R
_R
JL
ie be lt4
8.
rv t
-0
2-
:1
6:
PM
MEMORIAL WALL - PRECAST
DETAILS
DAYTON NATIONAL CEMETERY
GRAVESITE EXPANSION
4400 W THIRD ST, DAYTON, OH 45428
810CM3033
DECEMBER 5, 2025 JD RJL18125
LS501
6" = 1'-0"8 MEMORIAL WALL EDGE ATTACHMENT DETAIL, TYP.
12" = 1'-0"4 MEMORIAL WALL PLAQUE MARKER ATTACHMENT SECTION DETAIL
3" = 1'-0"2 MEMORIAL WALL PLAQUE MARKER, TYP.
NOT TO SCALE3 MEMORIAL WALL PLAQUE MARKER ATTACHMENT - ISOMETRIC
6" = 1'-0"6 MEMORIAL WALL TOP EDGE ATTACHMENT DETAIL, TYP.
6" = 1'-0"7 MEMORIAL WALL BOTTOM EDGE ATTACHMENT DETAIL, TYP.
3/4" = 1'-0"1 MEMORIAL WALL PRECAST UNIT
1" = 1'-0"5 PRECAST MEMORIAL WALL WELD PLATE DETAILS
NICHE COVER (VA SUPPLIED;
CONTRACTOR INSTALLED)
PRECAST COLUMBARIUM UNIT
ANCHOR
PRE-CAST COLUMBARIUM UNIT
TYPE 1 HORIZONTAL CELL VENT.
SPACED BETWEEN NICHE/NICHE &
NICHE/VENEER JUNCTION
3/8" SEALANT W/BACKER ROD
DECORATIVE AGGREGATE, 6"
DEPTH MIN.
CAST-IN-PLACE STEM WALL
THICKENED EDGE CONCRETE
PAVEMENT
FREE-DRAINING AGGREGATE/
GRANULAR DRAINAGE BACKFILL
WRAP DRAINAGE FILL WITH NON-WOVEN
GEOTEXTILE FABRIC.
OVERLAP @ TOP 6" MIN.
4" HDPE PERFORATED DRAINTILE;
(SEE UTILITY PLAN) UNDERDRAIN SLOPE
@ .5% MIN.
STONE TYPE 1: BASE STONE;
MORTARED SOLID IN PLACE
DAMP PROOFING: EXTEND DOWN TO
COVER TOP OF SPREAD FOOTING
1'- 0"
COMPACTED AGGREGATE BASE
SEE CIVIL
5/
8"
1"
5"
DRIP EDGE FLASHING
SEE SITE PLAN
VARIES
STONE TYPE 1: FULL VENEER
3/8" CONCAVE MORTAR JOINT
SEALANT
CONTINUOUS TERMINATION BAR
MORTAR MESH MINIMUM 18" ABOVE MORTAR
HAUNCH
TYPE 1 CELL VENT AT EACH JOINT (BEYOND)
MORTAR HAUNCH
CONTINUOUS SELF ADHESIVE EPDM
MEMBRANE
3/8" MORTAR JOINT
DECORATIVE AGGREGATE, 6" DEPTH MIN.
THICKENED-EDGE CONCRETE PAVEMENT.
DAMP PROOFING: EXTEND DOWN TO COVER TOP
OF SPREAD FOOTING
1'- 6"
7 5 /8"
TY
P.
5 1/4"
1 5/8"
FREE-DRAINING AGGREGATE/GRANULAR
DRAINAGE BACKFILL
COMPACTED AGGREGATE BASE
SEE CIVIL
STONE TYPE 1: FULL VENEER
3/8" CONCAVE MORTAR JOINT
SEALANT
CONTINUOUS TERMINATION BAR
MORTAR MESH MINIMUM 18" ABOVE MORTAR
HAUNCH
TYPE 1 CELL VENT AT EACH JOINT (BEYOND)
MORTAR HAUNCH
CONTINUOUS THRU WALL FLASHING WITH DRIP
3/8" CONCAVE MORTAR JOINT. TYP.
DAMP PROOFING: EXTEND DOWN TO COVER TOP
OF SPREAD FOOTING
CONTINUOUS SELF ADHESIVE EPDM
MEMBRANE
FINISHED GRADE
3 5 /8"
7 5 /8"
5/
8"
NOTE:
SEE 1/LS513 FOR
STONE SIZES
STONE SIZE B. TYP.
STONE SIZE C. TYP.
STONE SIZE B. TYP.
STONE SIZE A. TYP.
5/
8"
5 1/4"
6"
1'- 6"
1 5/8"
STONE TYPE 2: FULL
VENEER
3/8" CONCAVE
MORTAR JOINT
SEALANT
CONTINUOUS TERMINATION
BAR
MORTAR MESH MINIMUM 18"
ABOVE MORTAR HAUNCH
TYPE 1 CELL VENT, (BEYOND)
AT EACH JOINT
MORTAR HAUNCH
CONTINUOUS THRU
WALL FLASHING
3/8" CONCAVE MORTAR JOINT.
DECORATIVE AGGREGATE, 6"
DEPTH MIN.
THICKENED-EDGE CONCRETE
PAVEMENT
DAMP PROOFING: EXTEND DOWN TO
COVER TOP OF SPREAD FOOTING
COMPACTED AGGREGATE BASE
CONTINUOUS SELF ADHESIVE
EPDM MEMBRANE
5 1/4"
1'- 6"
3/
8"
1 5/8"
NON-WOVEN GEOTEXTILE FABRIC
STONE TYPE 2: ASHLAR
3/8" CONCAVE MORTAR
JOINT
SEALANT
CONTINUOUS TERMINATION BAR
MORTAR MESH MINIMUM 18"
ABOVE MORTAR HAUNCH
TYPE 1 CELL VENT, (BEYOND)
AT EACH JOINT
MORTAR HAUNCH
CONTINUOUS THRU WALL
FLASHING
3/8" MORTAR JOINT
CONTINUOUS SELF ADHESIVE
EPDM MEMBRANE
FINISHED GRADE
DAMP PROOFING: EXTEND DOWN TO
COVER TOP OF SPREAD FOOTING
1 5/8"
1'- 6"
STONE TYPE 1: BANDING
SEE 1/LS513 FOR STONE SIZING
5 9/128"
TY
P.
1'- 0"
STONE TYPE 1: FULL VENEER
3/8" CONCAVE MORTAR JOINT
SEALANT
CONTINUOUS TERMINATION BAR
MORTAR MESH MINIMUM 18" ABOVE
MORTAR HAUNCH
TYPE 1 CELL VENT, (BEYOND) AT
EACH JOINT
MORTAR HAUNCH
CONTINUOUS SELF ADHESIVE EPDM
MEMBRANE
3/8" MORTAR JOINT
THICKENED-EDGE CONCRETE PAVEMENT
DAMP PROOFING: EXTEND DOWN TO
COVER TOP OF SPREAD FOOTING
5 1/4"
1'- 6"
8"
1 5/8"
COMPACTED AGGREGATE BASE
SEE CIVIL
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
Office of
Design and Construction
Services U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
IRRIGATION:
WATER IN
MOTION, INC.
GEOTECHNICAL:
TERRACON
COST ESTIMATING:
OCMI
175 JAMES AVENUE NORTH
MINNEAPOLIS, MN 55405
952.229.1911
TIMOTHY MALOOLY
611 LUNKEN PARK DRIVE
CINCINNATI, OHIO 45226
513.612.9020
JEFF DUNLAP, PE
2100 NORTH GREENVILLE AVENUE
RICHARDSON, TEXAS 75082
469.431.0571
KYLE VEATER
BID DOCUMENTS
C :\U se rs
\rl ie be lt\
D oc um en ts \1
D N
C C ol um ba riu m _R
JL
ie be lt4
8.
rv t
-0 2-
:1 9:
PM
WALL DETAILS DAYTON NATIONAL CEMETERY
GRAVESITE EXPANSION
4400 W THIRD ST, DAYTON, OH 45428
810CM3033
DECEMBER 5, 2025 JAF RJL18125
LS502
3" = 1'-0"1 NICHE WALL BASE SECTION DETAIL
3" = 1'-0"2 COLUMN BASE AT PAVEMENT SECTION DETAIL
3" = 1'-0"3 COLUMN BASE AT SOFTSCAPE SECTION DETAIL
3" = 1'-0"4 CONNECTOR WALL BASE AT PAVEMENT SECTION DETAIL
3" = 1'-0"5 CONNECTOR WALL BASE AT SOFTSCAPE SECTION DETAIL
3" = 1'-0"6 WING WALL AT PAVEMENT SECTION DETAIL
FIELD DRILL AT LOACTION AND ANGLE AS PER
PRECAST COLUMBARIUM MANUFACTURER, EPOXY
STAINLESS STEEL PIN IN-PLACE
PRECAST NICHE UNITS
TYPE 2 STONE VENEER,
WHERE APPLICABLE
SEE CAP PROFILES AND LAYOUT PLANS
CAP SIZING VARIES BY SETTING CONDITION;
FIELD DRILL AT LOCATION AND ANGLE AS
PER PRECAST COLUMBARIUM
MANUFACTURER, EPOXY STAINLESS PIN
IN-PLACE
PRECAST NICHE UNITS
SEE CAP PROFILES AND LAYOUT PLANS
CAP SIZING VARIES BY SETTING CONDITION;
LS503
4 TYP
LS503
5 TYP
LS503
5 TYP
SINGLE SIDED
DOUBLE SIDED
TYPE 1 CELL VEMT (HORIZONTAL). PLACE AT
EVERY CAP JOINT
CONT. SELF ADHESIVE EPDM MEMBRANE,
HOLD MEMBRANE BACK 1/2" FROM FACE
TYPE 1 CELL VENT (VERTICAL). CELL VENT
SHALL NOT EXTEND PAST STONE VENEER
FACE, SPACE LONGITUDINALLY EVERY 24"-36".
STONE TYPE 1: CAP
3/8" BACKER ROD AND SEALANT
STONE TYPE 2 VENEER
CONT. SELF-ADHESIVE EPDM MEMBRANE,
OVERLAP 3", HOLD BACK 1/2" FROM FACE.
LS503
6 TYP
LS503
6 TYP
1/4" CHAMFER ALL TOP
EDGES, TYP.
STONE TYPE1 : CAP
STONE TYPE1 : CAP
CONTINUOUS SELF
ADHESIVE EPDM
MORTAR & SHIMS AS
NECESSARY
TYPE 1 HORIZONTAL
CELL VENTS; LOCATE
AT EACH CAP JOINT
1/4" CHAMFER ALL
TOP EDGES, TYP.
6-5/8" OVERHANG 6-5/8" OVERHANG
1/4" 1/4
1/4"
1/4
CONTINUOUS SELF
ADHESIVE EPDM
MORTAR & SHIMS AS
NECESSARY
TYPE 1 HORIZONTAL
CELL VENTS; LOCATE
AT EACH CAP JOINT
CONTINOUS 1/2" SEALANT W/
BACKER ROD ALONG CAP SEAM
SINGLE SIDED DOUBLE SIDED
CL
DRIP EDGE
CONTINUOUS
AROUND CAP
1/2" 1"3/8
1/4"
CONTINUOUS 1/2"
SEALANT W/BACKER
ROD ALONG CAP
SEAM
PRECAST NICHE UNITS
CONTINUOUS STAINLESS STEEL
FLASHING
STONE TYPE 1: FULL VENEER
1/2" SEALANT AND BACKER ROD
3/8" SEALANT AND BACKER ROD
6X6X5/16 STAINLESS STEEL ANGLE LINTEL SHELF
3/8" SEALANT AND BACKER ROD
STONE TYPE 1: CAP
CAST-IN-PLACE CONCRETE
STEM WALL
1/2" DIA. SIMPSON TITEN HD SCREW ANCHOR
EMBEDDED IN EPOXY 3-1/4" MIN. 2 SCREW
ANCHORS PER LINTEL MIN.
CONTINUOUS SELF ADHESIVE EPDM
1'- 4"
SE
E
1/L S2
VA
RI
ES
T.O.W.
SEE 1/LS100
STONE TYPE 1: FULL VENEER 3/4"
RECESS COURSING SHALL BE
EXTRUDED TO BE FLUSH WHERE
STONE ABUTS CAP.
FIELD DRILL AT LOCATION AND ANGLE
AS PER STONE CAP MANUFACTURER,
EPOXY STAINLESS PIN IN-PLACE
3/8" SEALANT W/BACKER ROD, CONT.
ALONG CAP JOINT.
CONTINUOUS SELF
ADHESIVE EPDM
CAST-IN-PLACE CONCRETE. STEM
WALL, SEE PLANS
SEE CAP PROFILES AND LAYOUT PLANS
CAP SIZING VARIES BY SETTING CONDITION;
STONE VENEER
LS503
6 TYP
OVERHANG
6 5/8"
T.O.W.
SEE 1/LS100
FIELD DRILL AT LOCATION AND ANGLE
AS PER STONE CAP MANUFACTURER,
EPOXY STAINLESS PIN IN-PLACE
3/8" SEALANT W/BACKER ROD, CONT.
ALONG CAP JOINT.
CONT. SELF
ADHESIVE EPDM
CAST-IN-PLACE CONCRETE.
STEM WALL, SEE PLANS
SEE CAP PROFILES AND LAYOUT PLANS
CAP SIZING VARIES BY SETTING CONDITION;
STONE TYPE 1: FULL VENEER
LS503
6 TYP
OVERHANG
2"
T.O.W.
SEE 1/LS100
3/8"
HORIZONTAL CELL VENT
STONE TYPE 1; STONE
CAP
JOINT SEALANT
BACKER ROD
3/ 8"
TOP OF NICHE UNIT,
MEMORIAL WALL & ENTRY WALL
CONTINUOUS SELF-ADHESIVE
EPDM AND FLASHING
VERT CELL VENT
STONE CAP
JOINT SEALANT
BACKER ROD
TOP OF NICHE/MEMORIAL
WALL UNIT
1/ 2"
1/2"
COLUMN STONE VENEER
PROVIDE SMOOTH SURFACE ON
STONE FACE AT AREA TO RECEIVE
SEALANT & BACKER ROD
M
IN1"
CONTINUOUS SELF-ADHESIVE
EPDM AND FLASHING
3/8" BACKER ROD AND SEALANT
STONE TYPE 1: FULL VENEER
PRECAST NICHE UNIT
PROVIDE SMOOTH
SURFACE ON STONE
FACE AT AREA TO
RECEIVE SEALANT AND
BAKER ROD
MI
N1"
CONTINUOUS STAINLESS
STEEL FLASHING
STONE TYPE 1: FULL
VENEER
1/2" SEALANT AND BACKER ROD
3/8" SEALANT AND
BACKER ROD
3/8" SEALANT AND BACKER ROD
STONE TYPE 1: CAP
CAST-IN-PLACE COLUMN
STEM WALL
CONTINUOUS SELF ADHESIVE EPDM
STAINLESS STEEL
MASONRY TIES, TYP.
STONE TYPE 1: FULL VENEER 3/4"
RECESS COURSING SHALL BE
EXTRUDED TO BE FLUSH WHERE
STONE ABUTS CAP.
T.O.W.
SEE 1/LS100
T.S.W.
SEE 1/LS100
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
Office of
Design and Construction
Services U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
IRRIGATION:
WATER IN
MOTION, INC.
GEOTECHNICAL:
TERRACON
COST ESTIMATING:
OCMI
175 JAMES AVENUE NORTH
MINNEAPOLIS, MN 55405
952.229.1911
TIMOTHY MALOOLY
611 LUNKEN PARK DRIVE
CINCINNATI, OHIO 45226
513.612.9020
JEFF DUNLAP, PE
2100 NORTH GREENVILLE AVENUE
RICHARDSON, TEXAS 75082
469.431.0571
KYLE VEATER
BID DOCUMENTS
C :\U se rs
\rl ie be lt\
D oc um en ts \1
D N
C C ol um ba riu m _R
JL
ie be lt4
8.
rv t
-0 2-
:1 9:
PM
CAP SETTING DETAILS DAYTON NATIONAL CEMETERY
GRAVESITE EXPANSION
4400 W THIRD ST, DAYTON, OH 45428
810CM3033
DECEMBER 5, 2025 JAF RJL18125
LS503
1 1/2" = 1'-0"1 NICHE WALL CAP SETTING SECTION DETAIL, TYP
3" = 1'-0"4 CAP SETTING AT VENEER DETAIL, TYP.
3" = 1'-0"5 NICHE UNIT CAP SETTING DETAIL, TYP.
6" = 1'-0"6 CAP DRIP EDGE DETAIL, TYP
3" = 1'-0"10 ANGLE LINTEL SHELF DETAIL, TYP.
1 1/2" = 1'-0"3 COLUMN CAP SETTING, DOUBLE-SLOPE SECTION DETAIL
1 1/2" = 1'-0"2 COLUMN CAP SETTING, SINGLE-SLOPE SECTION DETAIL
6" = 1'-0"7 NATURAL STONE CAP JOINT ELEVATION DETAIL, TYP.
6" = 1'-0"8 NATURAL STONE CAP AT VENEER JOINT ELEVATON DETAIL, TYP.
6" = 1'-0"9 BACKER ROD & SEALANT AT CONCRETE TO STONE DETAIL
3" = 1'-0"11 COLUMN TO C.I.P. CONCRETE DETAIL, TYP.
A8"
LETTERS AND NUMBERS SHALL BE
BRONZE, POST MOUNTED IN EPOXY TO
MATCH EXISTING COLUMBARIA "A"
WALL ID LETTERING
TE
XT
HE
IG
HT
1.
2.
3.
4.
5.
NOTES:
FONT TO MATCH EXISTING COLUMBARIA "A"
ALL CHARACTERS TO BE BRONZE INDICATORS POST MOUNTED IN EPOXY.
SEE ELEVATIONS FOR ROW INDICATOR LOCATIONS.
SEE ADDRESSING PLANS LS140 AND LS 141 FOR COLUMN MARKER AND WALL ID LOCATIONS
INDICATORS TO BE CENTERED ON PLAQUE COVER PLATES, SEE 2LS/504 AND 3/LS504.
A
ROW ID MARKER
FIELD DRILL AND SET BRONZE MARKER, POST
MOUNTED IN EPOXY SET INTO STONE VENEER
TO MATCH EXISTING COLUMBARIA "A"
COLUMN ID MARKER
FIELD DRILL AND SET BRONZE MARKER, POST
MOUNTED IN EPOXY SET INTO STONE CAP TO
MATCH EXISTING COLUMBARIA "A"
2" 2"
2"
BOTTOM OF CAP
COLUMBARIUM NICHE
COVER
FACE OF STONE CAP102"
LS504
1 TYP
EQ EQ
MEMORIAL WALL MARBLE
PLAQUE
FACE OF STONE CAP102"
LS504
1 TYP
EQ EQ MEMORIAL WALL MARBLE
BORDER
CL
CL
6"
6"
4"
4"
R 3"
R 3"
HANDRAIL TO
RETURN AND
CLOSE ON ITSELF
WITH CONTINUOUS
SMOOTH SURFACE
CLOSED LOOP
CONNECTION
R 3"
R 3"
CL
1-1/2" DIA. METAL
POST
3" DIA. STAINLESS STEEL
ESCUTCHEON COVER PLATE
BY MANUFACTURER
CORE DRILLED POST INTO
CONCRETE STEP, 6" MIN.;
NON-SHRINK GROUT PER
MANUFACTURER
RECOMMENDATIONS
2" 1'-0"
3" 5"
LIGHT DUTY CONCRETE
PAVEMENT; SEE 5/CS504
AMENDED TOP SOIL, 2'-0" DEPTH MIN.
6" DEPTH COMPACTED AGGREGATE BASE.
APPROVED COMPACTED SUBGRADE
3" MULCH PLANTING BED, MIN.
PLANTING FABRIC
6"
6"
1 1 /2"
R 1/ 2"
TY
P.CONTROL JOINT
NEW ROOT BARRIER. EXTEND 4'-0" BELOW
FINISHED GRADE.
1A B
C
D
E
EQEQ
CL
NICHE ROW ID MARKER, TYP.
LOCATE NICHE ROW ID'S ON EACH
COLUMN SIDE WALL FACING
COLUMBARIA NICHE UNITS.
CL
CL
CL
CL
CL
CL
WALL ID LETTERING
LOCATE WALL ID ON EACH COLUMN
SIDE WALL FACING COLUMBARIA
NICHE UNITS.
CL
NICHE COLUMN ID
COLUMN IDENTIFICATION NUMBER
POST IS ALIGNED TO CENTER OF
MARBLE NICHE COVER. LOCATION
AS SHOWN ON ADDRESSING PLAN
INTERIOR CORNER COLUMN
3CL
CL
CL
CL
WALL ID LETTERING
LOCATE WALL ID ON EACH
COLUMN SIDE WALL FACING
COLUMBARIA NICHE UNITS.
NICHE COLUMN ID
COLUMN IDENTIFICATION NUMBER POST IS
ALIGNED TO CENTER OF MARBLE NICHE
COVER. LOCATION AS SHOWN ON
ADDRESSING PLAN
CL
WALL ID LETTERING
LOCATE WALL ID ON EACH
COLUMN SIDE WALL
FACING COLUMBARIA
NICHE UNITS.
EQ EQ
EQ EQ
CENTER COLUMN EXTERIOR CORNER AND END COLUMN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
Office of
Design and Construction
Services U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
IRRIGATION:
WATER IN
MOTION, INC.
GEOTECHNICAL:
TERRACON
COST ESTIMATING:
OCMI
175 JAMES AVENUE NORTH
MINNEAPOLIS, MN 55405
952.229.1911
TIMOTHY MALOOLY
611 LUNKEN PARK DRIVE
CINCINNATI, OHIO 45226
513.612.9020
JEFF DUNLAP, PE
2100 NORTH GREENVILLE AVENUE
RICHARDSON, TEXAS 75082
469.431.0571
KYLE VEATER
BID DOCUMENTS
C :\U se rs
\rl ie be lt\
D oc um en ts \1
D N
C C ol um ba riu m _R
JL
ie be lt4
8.
rv t
-0 2-
:1 9:
PM
COLUMBARIUM - DETAILS DAYTON NATIONAL CEMETERY
GRAVESITE EXPANSION
4400 W THIRD ST, DAYTON, OH 45428
810CM3033
DECEMBER 5, 2025 JAF RJL18125
LS504
1 1/2" = 1'-0"1 COLUMBARIUM AND MEMORIAL WALL LETTERING AND NUMBERING
1 1/2" = 1'-0"2 NICHE COLUMN ID MARKER NUMBERING
1 1/2" = 1'-0"3 MEMORIAL WALL COLUMN ID MARKER NUMBERING
3" = 1'-0"6 STAIRCASE RAILING DETAIL
3" = 1'-0"7 HANDRAIL POST SETTING DETAIL
1 1/2" = 1'-0"8 LANDSCAPE EDGER CURB, TYP.
3/4" = 1'-0"4 COLUMBARIUM INTERIOR CORNER COLUMN ID PLACEMENT DETAIL
3/4" = 1'-0"5 COLUMBARIUM CENTER COLUMNS END COLUMNS AND EXTERIOR CORNERS ID PLACEMENT DETAIL
LS301
MW1
CL
CL
CL
WALL ID LETTERING
LOCATE WALL ID ON EACH COLUMN
SIDE WALL FACING MEMORIAL WALL
COURT INTERIOR.
PLAQUE MARKER WALL COLUMN ID
COLUMN IDENTIFICATION NUMBER
POST IS ALIGNED TO CENTER OF
MARBLE PLAQUE COVER. PLAQUE
ID'S SHALL FACE COURT INTERIOR.
LOCATION AS SHOWN ON
ADDRESSING PLAN
CL
PLAQUE ROW ID MARKER, TYP.
PLAQUE ROW ID'S ON EACH COLUMN SHALL FACE
MEMORIAL WALL PLAQUES
CL
CL
CL
CL
CL
CL
CL
1 3/8" 3 3/4" 1/4" 11 1/4" 1/4"
1 3 /8"
3 1 /2"
1/4
7 3 /4"
1/4
3/4" THICK BORDER STONE
ALL EDGES OF THE
FRONT, BACK, AND
CORNERS SHALL BE
SMOOTH SAWN AND
FINISHED WITH A
CLEAN 1/8" ARIS
(EASED EDGE)
HORIZONTAL
BORDER STONE
MEMORIAL
WALL MARKER
CORNER
BORDER STONE
VERTICAL BORDER STONE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
Office of
Design and Construction
Services U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
IRRIGATION:
WATER IN
MOTION, INC.
GEOTECHNICAL:
TERRACON
COST ESTIMATING:
OCMI
175 JAMES AVENUE NORTH
MINNEAPOLIS, MN 55405
952.229.1911
TIMOTHY MALOOLY
611 LUNKEN PARK DRIVE
CINCINNATI, OHIO 45226
513.612.9020
JEFF DUNLAP, PE
2100 NORTH GREENVILLE AVENUE
RICHARDSON, TEXAS 75082
469.431.0571
KYLE VEATER
BID DOCUMENTS
C :\U se rs
\rl ie be lt\
D oc um en ts \1
D N
C M em or ia l W al l_
R
_R
JL
ie be lt4
8.
rv t
-0
2-
:1
6:
PM
MEMORIAL WALL - DETAILS DAYTON NATIONAL CEMETERY
GRAVESITE EXPANSION
4400 W THIRD ST, DAYTON, OH 45428
810CM3033
DECEMBER 5, 2025 JD RJL18125
LS505
1" = 1'-0"1 MEMORIAL WALL COLUMN ID PLACEMENT DETAIL
1" = 1'-0"2 MEMORIAL WALL ROW ID PLACEMENT DETAIL
3" = 1'-0"3 MEMORIAL WALL PLAQUE MARKER DETAIL
3/8
2"1"
3'-0"
3/8"
2" 1"
3/8
3/8"
2'-11 1/4"
2'-
5/
8"EQ EQ
EQ
EQ
APPROXIMATE LOCATION
OF VA SEAL PLAQUE SOLID
METAL SETTING NOTCH ON
BACK OF SEAL; PER
MANUFACTURER
ROPE FINISH
CONTINUOUS
MEDIUM PEBBLE FINISH FOR
ALL BACKGROUND AREAS
STONE TYPE 1
ELEVATION
APPROXIMATE LOCATION
OF VA SEAL PLAQUE SOLID
METAL SETTING NOTCH ON
BACK OF SEAL; PER
MANUFACTURER
3'- 0 3
/8"
2" 1"
1"
3/8"
STONE TYPE 1:
CEMETERY ADDRESS
PLAQUE
6" METAL LETTERING
MOUNTED TO PLAQUE
4" METAL LETTERING
MOUNTED TO PLAQUE
4'-11 1/4"3/8"4'-11 1/4"
1 3 /16
8 5
/8" 9 5
/8" 9 1
3/1 6"
CL
CL
CL
ELEVATION
DRILL THROUGH NATURAL STONE (3 INCH
MINIMUM) TO CIP CONCRETE SUBSTRATE AND
FILL WITH MORTAR IMMEDIATELY BEFORE
SETTING SEAL
STONE TYPE 1
MASONRY TIE
NEOPRENE SLEEVE
SOLID METAL PORTION ON BACK OF SEAL. DRILL
AND TAP FOR STUD; 3 LOCATIONS AS INDICATED ON
ELEVATION.
VA SEAL
NATURAL STONE
CAST-IN-PLACE CONCRETE
STEM WALL
STONE TYPE 1: FULL VENEER
MASONRY TIE
1.
2.
3.
4.
NOTES:
SEE SPECIFICATIONS FOR MATERIAL,
WORKMANSHIP, FINISH, COATING, AND
FASTENERS.
VA SEAL IS TO BE SUPPLIED AND
INSTALLED BY THE CONTRACTOR.
VA SEAL: 23-1/4" DIA.
SUBMIT SHOP DRAWINGS.
SECTION
SEALANT & BACKER ROD
SEALANT & BACKER ROD
DRILL THROUGH NATURAL STONE (3 INCH
MINIMUM) TO CIP CONCRETE SUBSTRATE AND
FILL WITH MORTAR IMMEDIATELY BEFORE
SETTING SEAL
NEOPRENE SLEEVE
STONE TYPE 1
DRILL THROUGH NATURAL STONE TO
CIP CONCRETE SUBSTRATE AND FILL
WITH MORTAR IMMEDIATELY BEFORE
SETTING LETTERING
STAND OFF METAL LETTERING, TYP.
3/8" DIA. STAINLESS STEEL THREADED
STUD SCREWED INTO FABRICATED
THREADED SLOTS. POSITION LETTERS
INTO HOLES WHILE MORTAR IS DAMP.
NEOPRENE SLEEVE
STONE TYPE 1: ADDRESSING STONE
CAST-IN-PLACE CONCRETE STEM WALL
SECTION
MASONRY TIE EMBEDDED IN NON-
SHRINK MORTAR
SEALANT & BACKER ROD
1.
2.
NOTES:
SEE SPECIFICATIONS FOR MATERIAL,
WORKMANSHIP, FINISH, COATING, AND
FASTENERS.
SUBMIT SHOP DRAWINGS.
MORTAR MESH IN AIRSPACE, FULL
HEIGHT OF WALL/COLUMN
STONE TYPE 1: FULL
VENEER
CAST-IN-PLACE STEM WALL
ORNAMENTAL FENCE
1'- 6"
CAST-IN-PLACE STEM
WALL SEE STRUCTURAL
MORTAR MESH IN
AIRSPACE FULL HEIGHT
OF WALL/COLUMN
STONE TYPE 1:
FULL VENEER
THICKENED EDGE
CONCRETE
PAVEMENT; SEE
DETAIL 15/CS504
ORNAMENTAL
GATE POST; SEE
CIVIL
1'- 6"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
Office of
Design and Construction
Services U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
IRRIGATION:
WATER IN
MOTION, INC.
GEOTECHNICAL:
TERRACON
COST ESTIMATING:
OCMI
175 JAMES AVENUE NORTH
MINNEAPOLIS, MN 55405
952.229.1911
TIMOTHY MALOOLY
611 LUNKEN PARK DRIVE
CINCINNATI, OHIO 45226
513.612.9020
JEFF DUNLAP, PE
2100 NORTH GREENVILLE AVENUE
RICHARDSON, TEXAS 75082
469.431.0571
KYLE VEATER
BID DOCUMENTS
C :\U se rs
\rl ie be lt\
D oc um en ts \1
D N
C E nt ry
W al l_ R
_R
JL
ie be lt4
8.
rv t
-0 2-
:2 4:
PM
ENTRY WALL - DETAILS DAYTON NATIONAL CEMETERY
GRAVESITE EXPANSION
4400 W THIRD ST, DAYTON, OH 45428
810CM3033
DECEMBER 5, 2025 JAF RJL18125
LS506
1 1/2" = 1'-0"1 ENTRY WALL STONE VA SEAL PLAQUE - EAST WALL
1 1/2" = 1'-0"2 ENTRY WALL STONE CEMETERY SIGN - WEST WALL
3" = 1'-0"3 ENTRY WALL COLUMN ORNAMENTAL FENCE - TYP.
3" = 1'-0"4 ENTRY WALL ORNAMENTAL FENCE - TYP.
C1.1-PLAN
LENGTH
3'-0 9/16"
SL
AB4" PE
AK6"
LENGTH
4'-0 9/16"
C1.2-PLAN
LENGTH
4'-11 5/8"
C1.3-PLAN
LENGTH
5'-2 1/2"
C1.4-PLAN
LENGTH
5'-0 9/16"
C1.5-PLAN
C2.1-PLAN
LENGTH
3'-0 9/16"
SL
AB4" PE
AK6"
C2.2-PLAN
LENGTH
3'-11 5/8"
C2.3-PLAN
LENGTH
4'-11 5/8"
C2.4-PLAN
LENGTH
5'-0 9/16"
C4.1PLAN
C4.1-RIGHT
C4.1-FRONT
SL
AB4"
PE
AK6"
PE
AK6"
SL
AB4"
W
ID
TH
2'-
7 1 /2"
LENGTH
3'-7 1/2"
C4.2-PLAN
C4.2 - FRONT & RIGHT
SL
AB4"
PE
AK6"
W
ID
TH
3'-
7 1 /2"
LENGTH
3'-7 1/2"
C4.3-PLAN
C4.3-RIGHT
C4.3-FRONT
SL
AB4"
PE
AK6"
PE
AK6"
SL
AB4"
W
ID
TH
3'-
7 1 /2"
LENGTH
3'-7 1/2"
C4.4-PLAN
C4.4 - RIGHT
C4.4 - FRONT
SL
AB4"
PE
AK6"
PE
AK6"
SL
AB4"
W
ID
TH
2'-
7 1 /2"
LENGTH
5'-8"
TYPICAL C2 - PROFILE
VERTICAL FACE
BELOW
VERTICAL FACE
BELOW
VERTICAL FACE BELOW
CONTINUOUS
DRIP EDGE
RIDGE
OV
ER
HA
NG
T
YP
2"
OV
ER
HA
NG
T
YP
6 5
/8"
OV
ER
HA
NG
6 5 /8"
OV
ER
HA
NG
6 5 /8"
CONTINUOUS DRIP EDGE
TYPICAL C1 - PROFILE
WIDTH
2'-0"
WIDTH
2'-0"
LENGTH 2
2'-6"
LENGTH 1
2'-6"
169.00°
OVERHANG
2 3/4"
W2.1-PLAN
WIDTH
2'-0"
PE
AK6"
SL
AB4"
CONTINUOUS
DRIP EDGE, TYP.
W2.1-FRONT
WIDTH
2'-0"
W
IDTH
2'-0"
LE
NG
TH
2'- 6"
LENGTH 2
2'-6"
89.00°
W2.2-PLAN
WIDTH
2'-0"
OVERHANG
1'-5 23/32"
OVERHANG
1'-0 7/32"
SL
AB4"
PE
AK6"
W2.2-FRONT
WIDTH
2'-0"
W
IDTH
2'-0"
LE
NG
TH
2'- 6"
LENGTH 2
2'-6"
88.00°
W2.3-PLAN
WIDTH
2'-0"
SL
AB4"
PE
AK6"
W2.3-FRONT W2.4-PLAN
W2.4, W2.5, W2.6, W2.7, W2.8-RIGHT
W
ID
TH
2'-
0"
LENGTH
4'-3 3/4"
VERTICAL FACE
BELOW, TYP.
PE
AK6"
WIDTH
2'-0"
CONTINUOUS
DRIP EDGE
W2.5-PLAN
W
ID
TH
2'- 0"
LENGTH
4'-1"
W3.2-PLAN
W
ID
TH
2'-
0"
LENGTH
4'-7"
W3.1-PLAN
W
ID
TH
2'-
0"
LENGTH
4'-3 1/2"
W3.3-PLAN
LENGTH
4'-4 1/2"
W
ID
TH
2'-
0"
OV
ER
HA
NG
2"
OV
ER
HA
NG
2 3
/4"
OVERHANG
2 3/4"
OVERHANG
2 3/4"
C1.6-PLAN
LENGTH
3'-11 5/8"
C2.5-PLAN
LENGTH
2'-11 5/8"
CONTINUOUS
DRIP EDGE
CONTINUOUS DRIP
EDGE, TYP.
1'-3 1/8" RIDGE
WIDTH
2'-11 5/8"
NOTE:
1.REFER TO LS130 FOR CAP LAYOUT PLANS AND POSITIONING.
2.ALL VISIBLE TYPE C1 STONE CAP FACES SHALL HAVE A
CONTINUOUS DRIP EDGE SET BACK 1".
4'-10 1/4"
NOTE:
1.REFER TO LS130 FOR CAP LAYOUT PLANS AND POSITIONING.
2.ALL VISIBLE TYPE C4 STONE CAP FACES SHALL HAVE A
CONTINUOUS DRIP EDGE SET BACK 1".
NOTE:
1.REFER TO LS130 FOR CAP LAYOUT PLANS AND POSITIONING.
2.ALL VISIBLE TYPE C2 STONE CAP FACES SHALL HAVE A
CONTINUOUS DRIP EDGE SET BACK 1".
1 1/2" RIDGE 2'-11 3/4" RIDGE
NOTE:
1.REFER TO LS130 FOR CAP LAYOUT PLANS AND POSITIONING.
2.ALL VISIBLE TYPE W2 STONE CAP FACES SHALL HAVE A
CONTINUOUS DRIP EDGE SET BACK 1".
OVERHANG
2"
OVERHANG
2 3/4"
OV
ER
HA
NG
2 3 /4"
OV
ER
HA
NG
2"
OV
ER
HA
NG
2 3 /4"
OV
ER
HA
NG
2 3 /4"
OVERHANG
2"
OVERHANG
2" OVERHANG
2 3/4"
OVERHANG
2 3/4"
OV
ER
HA
NG
2 3 /4"
OV
ER
HA
NG
2"
OVERHANG
2"
OV
ER
HA
NG
2 3 /4"
OV
ER
HA
NG
2 3 /4"
OVERHANG
2"
OV
ER
HA
NG
2 3 /4"
OV
ER
HA
NG
2 3 /4"
OVERHANG
2 3/4"
OVERHANG
2 3/4"
OVERHANG
2 3/4"
OVERHANG
2 3/4"
OVERHANG
2 3/4"
OVERHANG2 3/4"
OVERHANG2 3/4"
OVERHANG
3 3/256"
OVERHANG
2 125/256"
OV
ER
HA
NG
2 3 /4"
OV
ER
HA
NG
2 3 /4"
OV
ER
HA
NG
2 3 /4"
OV
ER
HA
NG
2 3 /4"
OVERHANG
2"
OV
ER
HA
NG
2 3 /4"
OV
ER
HA
NG
2 3 /4"
TY
PE
C
TY
PE
C
TY
PE
C
TY
PE
W
TY
PE
W
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
Office of
Design and Construction
Services U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
IRRIGATION:
WATER IN
MOTION, INC.
GEOTECHNICAL:
TERRACON
COST ESTIMATING:
OCMI
175 JAMES AVENUE NORTH
MINNEAPOLIS, MN 55405
952.229.1911
TIMOTHY MALOOLY
611 LUNKEN PARK DRIVE
CINCINNATI, OHIO 45226
513.612.9020
JEFF DUNLAP, PE
2100 NORTH GREENVILLE AVENUE
RICHARDSON, TEXAS 75082
469.431.0571
KYLE VEATER
BID DOCUMENTS
C :\U se rs
\rl ie be lt\
D oc um en ts \1
D N
C C ol um ba riu m _R
JL
ie be lt4
8.
rv t
-0 2-
:1 9:
PM
COLUMBARIUM - CAP PROFILES DAYTON NATIONAL CEMETERY
GRAVESITE EXPANSION
4400 W THIRD ST, DAYTON, OH 45428
810CM3033
DECEMBER 5, 2025 JAF RJL18125
LS510
3/4" = 1'-0"
COLUMBARIUM CAP PROFILES1
2'-7 1/2" WIDTH
M4.1 - PLAN M1.1-PLAN
2'-7 1/4" WIDTH
3'-7 1/2" LENGTH
3'-7 1/2" LENGTH
5'-2 9/16" LENGTH
6" P
EA
K
4" S
LA
B
2" OVERHANG2" OVERHANG
2" OVERHANG 2 3/4"OVERHANG
4" S
LA
B
6" P
EA
K
2'- 7 1
/2" W
ID
TH
2 3/4" OVERHANG 2 3/4" OVERHANG
M1.2-PLAN
O
VE
RH
AN
GE
2"
O
VE
RH
AN
G 2 3
/4"
2 3/4" OVERHANG 2 3/4" OVERHANG
5'-8 5/8" LENGTH
M4.1 - RIGHT M1.1 & M1.2 - PROFILE
M4.1-FRONT
CONTINUOUS
DRIP EDGE, TYP.
CONTINUOUS
DRIP EDGE, TYP.
VERTICAL FACE
BELOW, TYP.
EQ EQ
1'-3 5/8" RIDGE
NOTE:
1.REFER TO LS131 FOR CAP LAYOUT PLANS AND POSITIONING.
2.ALL VISIBLE TYPE M1 AND M4 STONE CAP FACES SHALL HAVE A
CONTINUOUS DRIP EDGE SET BACK 1" FROM FACE.
TY
PE
M
TY
PE
M
2" 2" 2"
2"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
Office of
Design and Construction
Services U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
IRRIGATION:
WATER IN
MOTION, INC.
GEOTECHNICAL:
TERRACON
COST ESTIMATING:
OCMI
175 JAMES AVENUE NORTH
MINNEAPOLIS, MN 55405
952.229.1911
TIMOTHY MALOOLY
611 LUNKEN PARK DRIVE
CINCINNATI, OHIO 45226
513.612.9020
JEFF DUNLAP, PE
2100 NORTH GREENVILLE AVENUE
RICHARDSON, TEXAS 75082
469.431.0571
KYLE VEATER
BID DOCUMENTS
C :\U se rs
\rl ie be lt\
D oc um en ts \1
D N
C M em or ia l W al l_
R
_R
JL
ie be lt4
8.
rv t
-0
2-
:1
6:
PM
MEMORIAL WALL - CAP PROFILES DAYTON NATIONAL CEMETERY
GRAVESITE EXPANSION
4400 W THIRD ST, DAYTON, OH 45428
810CM3033
DECEMBER 5, 2025 JD RJL18125
LS511
1" = 1'-0"
MEMORIAL WALL CAP PROFILES1
3'-11 1/2" LENGTH
2'- 7 1
/2" W
ID
TH
LENGTH
2'-1 15/32"
E4.1 - PLAN
E2.1 - PLAN E2.2 - PLAN E2.3 - PLAN E2.4 - PLAN
EQ
EQ
2 3/4" OVERHANG
2 3 /4"
O
VE
RH
AN
G
2 3 /4"
O
VE
RH
AN
G
2 3/4" OVERHANG
2 3/4" OVERHANG 2 3/4" OVERHANG
SL
AB4"
6" P
EA
K
2 3/4" OVERHANG 2 3/4" OVERHANG
2'-7 1/2"
3'-1" WIDTH
2 3/4" OVERHANG 2 3/4" OVERHANG
LENGTH
2'-5 13/16"
TYPICAL E2 CAP
PROFILE
E4 CAP PROFILE - RIGHT
E4 CAP PROFILE - FRONT
1'-2 1/2" RIDGE
VERTICAL FACE BELOW,
TYP.
NOTE:
1.REFER TO LS132 FOR CAP LAYOUT PLANS AND POSITIONING.
2.ALL VISIBLE TYPE E2 STONE CAP FACES SHALL HAVE A
CONTINUOUS DRIP EDGE SET BACK 1".
TY
PE
E
OV
ER
HA
NG
2 3 /4"
OV
ER
HA
NG
2 3 /4"
TY
PE
E
W
ID
TH
3'-
1"
PE
AK6"
SL
AB4"
LENGTH
3'-0 3/8"
E2.5 - PLAN
LENGTH
2'-2 17/32"
E2.6 - PLAN
LENGTH
2'-5 13/16"
LENGTH
2'-1 15/32"
4 1/4" 1 9/16"
4 1 /4" 1 15/16"
4 1 /4"
1 15/16"
4 1 /4"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
Office of
Design and Construction
Services U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
IRRIGATION:
WATER IN
MOTION, INC.
GEOTECHNICAL:
TERRACON
COST ESTIMATING:
OCMI
175 JAMES AVENUE NORTH
MINNEAPOLIS, MN 55405
952.229.1911
TIMOTHY MALOOLY
611 LUNKEN PARK DRIVE
CINCINNATI, OHIO 45226
513.612.9020
JEFF DUNLAP, PE
2100 NORTH GREENVILLE AVENUE
RICHARDSON, TEXAS 75082
469.431.0571
KYLE VEATER
BID DOCUMENTS
C :\U se rs
\rl ie be lt\
D oc um en ts \1
D N
C E nt ry
W al l_ R
_R
JL
ie be lt4
8.
rv t
-0 2-
:2 4:
PM
ENTRY WALL - WALL CAP
PROFILES
DAYTON NATIONAL CEMETERY
GRAVESITE EXPANSION
4400 W THIRD ST, DAYTON, OH 45428
810CM3033
DECEMBER 5, 2025 JAF RJL18125
LS512
1" = 1'-0"
ENTRY WALL CAP PROFILES1
STONE - A
FACE
BANDING STONE - TYP.
1'-11 5/8"
3 5 /8"
3 5 /8"
4 5/8"
1"
1"
1"
1"
7 5 /8"
3 5/8"1'-11 5/8"
FRONT RIGHT
STONE - B
5/
8"
3 5/8"1'-11 5/8"
FRONT RIGHT
STONE - C
3 5 /8"
3 5/8"1'-11 5/8"
FRONT RIGHT RIGHT
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA…