This is a bid document set for the Dayton National Cemetery Gravesite Expansion project, prepared by Anderson Engineering of Minnesota, LLC for the U.S. Department of Veterans Affairs. The project is located at 4400 W Third Street, Dayton, OH 45428, with bid documents issued February 5, 2026.
The demolition plan (PPC Section 51, Drawing CD112) outlines site preparation activities including removal of existing trees, abandoned sanitary sewer sealing, existing fencing, landscaping, bituminous and gravel pavement, and concrete elements within defined construction limits on South Gettysburg Avenue. The plan specifies contractor requirements to maintain safe distances from existing historical VA Medical Center buildings to prevent damage, implement temporary construction fencing and silt fence erosion control measures, establish rock construction entrances and inlet protection, and conduct sawcutting of bituminous pavement. The site map identifies existing utilities requiring protection or coordination, including water mains, sanitary and storm sewers, gas mains, overhead and underground electric lines, telephone lines, hydrants, and sanitary/storm sewer infrastructure. Construction limits and protective measures such as tree protection and rock silt fencing are clearly delineated on the demolition plan to facilitate safe execution of the gravesite expansion project.
View the file
Other files
Show all 44
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fil e P ath : y
:\1
\18
5 v a n ca m idw es t -da yto n n ati on al ce me ter y -da yto n o hio
\_0 7 c ivi l\_ ca d f ile s\_ sh ee ts\
5_ c_ de mo -2
.dw g ed it:m mi lle r sa ve d:7
/6/
:37 A
M
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18125
810-CM3-033
FEBRUARY 5, 2026
4400 W THIRD ST, DAYTON, OH 45428
BID DOCUMENTS
Date:
OF 159
Office of Design and Construction
Services
BID DOCUMENTS
DAYTON NATIONAL CEMETERY
GRAVESITE EXPANSIONGEOTECHNICAL
TERRACON
JEFF DUNLAP, PE
IRRIGATION
WATER IN
MOTION, INC.
TIMOTHY MALOOLY
COST ESTIMATING
OCMI
KYLE VEATER
G ettysburg A venue G ettysburg A venue
H A
W A
II P
LA
C E
Wisconsin Avenue
Pe nn sy lv an ia
A ve nu e
New Mexico Place
Ohi o
Av en ue
KEY MAP
175 James Avenue North Minneapolis, MN 55405 952.229.1911
611 Lunken Park Drive Cincinnati, Ohio 45226 513.612.9020
2100 North Greenville Ave. Richardson, Texas 75082 469.431.0571
N
N.T.S.
N 0 20' 40'
DEMOLITION PLAN - PPC SECTION 51
CD112
SO
U
TH
G
ET
TY
SB
U
R G
A
VE
N U
E
EXISTING
VA MEDICAL CENTER
HOUSE
EXISTING
VA MEDICAL CENTER
HOUSE
EXISTING
VA MEDICAL CENTER
FACILITY
EXISTING
VA MEDICAL CENTER
BUILDING
REMOVE EX. TREE (TYP.)
REMOVE EXISTING
ABANDONED SANITARY SEWER
SEAL ALL ABANDONED
OPENINGS
KE
N
ES
AW
A
VE
N U
E
W
IS
C O
N
SI
N A
VE
N
U E
SCALE:1
DEMOLITION PLAN - PPC SECTION 51
1"=20'
26BJNLRK
LEGEND
CONSTRUCTION LIMITS
EXISTING WATERMAIN
EXISTING SANITARY SEWER
EXISTING STORM SEWER
EXISTING FENCE
EXISTING GAS MAIN
EXISTING OVERHEAD WIRES
EXISTING TELEPHONE
EXISTING UNDERGROUND
ELECTRIC
EXISTING HYDRANT AND GV
EXISTING SANITARY MANHOLE
EXISTING STORM SEWER INLET
REMOVE EX. FENCE/UTILITY
REMOVE EXISTING
LANDSCAPING
REMOVE EXISTING BITUMINOUS
PAVEMENT
REMOVE EXISTING GRAVEL
PAVEMENT
SAWCUT BITUMINOUS PAVEMENT
REMOVE EXISTING CONCRETE
C&G
REMOVE TREE
ROCK SOCK
SILT FENCE
TEMPORARY CONSTRUCTION
FENCE
TREE PROTECTION
INLET PROTECTION
ROCK CONSTRUCTION ENTRANCE
CONSTRUCTION LIMITS
SILT FENCE (TYP.)
(SEE DETAIL 1/SHEET CS504)
TEMPORARY CONSTRUCTION FENCE (TYP)
(SEE DETAIL 14/SHEET CS504)
REMOVE EXISTING
ABANDONED SANITARY SEWER
SEAL ALL ABANDONED
OPENINGS
CONTRACTOR TO MAINTAIN SAFE DISTANCE
FROM EXISTING HISTORICAL BUILDINGS TO
AVOID ANY DAMAGE TO BUILDINGS. (TYP.)
2 ADDENDUM 2 7/8/26
PM Revisions: Date:
AMENDMENT 02 7/8/20262
| Sheets and Views |
| CD112 DEMOLITION PLAN - PPC SECTION 51 |
File details come from the government source that posted it. Updated .