Bid Drawings Volume 13 of 14_IRRIGATION_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf

PDF 13 MB Posted

Attached to
Y1PZ--810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton National Cemetery
Solicitation number
36C78626B0007
Issued by

About this file

These are bid documents for the Dayton National Cemetery Gravesite Expansion irrigation project located at 4400 W Third Street, Dayton, Ohio 45428. The project is issued by the U.S. Department of Veterans Affairs, Office of Design and Construction Services, with drawings prepared by Anderson Engineering of Minnesota, LLC (Project #18125, Drawing #810-CM3-033) and issued February 5, 2026. The documents total 133 pages and contain detailed irrigation plans, schedules, specifications, and installation details.

The scope of work includes comprehensive irrigation system modifications across multiple cemetery sections, encompassing equipment replacement, new installation, and system upgrades to accommodate gravesite expansion. Key deliverables include amendment and reinstallation of existing landscape irrigation distribution equipment (control valves, decoders, quick couplers, lateral piping, and sprinklers) with contemporary water-efficient sprinkler models; installation of approximately 100+ new turf and planting bed irrigation stations across various sections; replacement of existing conventional wire controllers with new decoder-based systems; installation of new pedestal-based irrigation controllers with Toro Sentinel DXI cellular internet-connected remote central control hardware and software including a Microsoft Surface Pro 10 tablet with WMS software; flow sensor installation with telecom cable hardwiring; irrigation booster pump station verification and performance adjustment; comprehensive training for owner personnel on system operation and maintenance with audio recording delivery; and reconnection of existing flower watering stations. The project involves six interconnected irrigation systems (Systems A through F) serving different cemetery sections with specific valve schedules, sprinkler placements, and pressure requirements documented in detailed irrigation schedules and plans.

View the file

Other files

File Type Posted
36C78626B0007 0003.docx DOCX document
CG108 GRADING and DRAINAGE PLAN - PPC SECTION 51.pdf PDF
CD112 DEMOLITION PLAN - PPC SECTION 51.pdf PDF
CG106 GRADING and DRAINAGE PLAN - PPC SECTIONS 48 and 52.pdf PDF
LS400A.pdf PDF
LS204.pdf PDF
Revised Davis Bacon Wage Determination_Heavy_OH20260001 06252026.pdf PDF
LS401.pdf PDF
CG100.pdf PDF
CD111 DEMOLITION PLAN _ PPC SECTION 49 and 50.pdf PDF
LS402.pdf PDF
10 14 00 Exterior Signage.pdf PDF
S001.pdf PDF
LS301.pdf PDF
CS502 SITE DETAILS - 2.pdf PDF
01 43 39 Mockup Requirements.pdf PDF
ES101 - Electrical Site Plan.pdf PDF
Revised Davis Bacon Wage Determination_Building_OH20260093 05182026.pdf PDF
LS400B.pdf PDF
36C78626B0007 0002.docx DOCX document
36C78626B0007 0001.docx DOCX document
Prebid Site Visit Attendance Record_20260612.pdf PDF
LS200_Pages from 18125 DNC_BID_20260211.pdf PDF
LS300_Pages from 18125 DNC_BID_20260211.pdf PDF
Davis Bacon Wage Determination _ Building _ OH20260093 01022026.pdf PDF
Bid Drawings Volume 3 of 14_C LOGI DEMO_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Bid Drawings Volume 1 of 14_GEN SURV_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
36C78626B0007_1.docx DOCX document
Davis Bacon Wage Determination _ Heavy _ OH20260001 01022026.pdf PDF
Bid Specifications 810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Bid Drawings Volume 11 of 14_C GRADE UTIL_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Bid Drawings Volume 12 of 14_L PLANTING_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Bid Drawings Volume 6 of 14_L SITE PRECAST_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Bid Drawings Volume 5 of 14_C GRAVESITE_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Bid Drawings Volume 2 of 14_C BORING_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Bid Drawings Volume 8 of 14_L CAPS ADDRESSING_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Bid Drawings Volume 14 of 14_STRUC ELECT_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Bid Drawings Volume 10 of 14_L SECTIONS DETAILS_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Bid Drawings Volume 9 of 14_L ELEVATIONS_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Bid Drawings Volume 7 of 14_L FLATWORK_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
VAAR 852.219-75 VA Notice of Limitations On Subcontracting Certificate.docx DOCX document
IFB Cost Estimate Worksheet.xlsx XLSX spreadsheet
Bid Drawings Volume 4 of 14_C SITE_810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Statement of Work 810CM3033 Gravesite Expansion with FCA Deficiencies at Dayton NC.pdf PDF
Show all 44

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GENERAL DIRECTION

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fil e P ath : c

:\u se rs\ co lin ce as on

\m alo oly pr op er tie s\w ate r in m oti on , in c -do cu me nts \w im pr oje ct fol de rs\ da yto n n ati on al ce me ter y -s1

2\d ay ton na tio na l c em ete ry d2

4-

-0

1\w or kb en ch \da yto n n ati on al ce me tey

.dw g ed it:c oli nc ea so n sa ve d:2

/6/

:43 P

M

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS

321 4 5 6 7 8 9 10

Project Director

Revisions:

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 18125

810-CM3-033

FEBRUARY 5, 2026

4400 W THIRD ST, DAYTON, OH 45428

TM CJC

BID DOCUMENTS

Date:

OF 133

Office of Design and Construction

Services

BID DOCUMENTS

DAYTON NATIONAL CEMETERY

GRAVESITE EXPANSIONGEOTECHNICAL

TERRACON

JEFF DUNLAP, PE

IRRIGATION

WATER IN

MOTION, INC.

TIMOTHY MALOOLY

COST ESTIMATING

OCMI

KYLE VEATER

175 James Avenue North Minneapolis, MN 55405 952.229.1911

611 Lunken Park Drive Cincinnati, Ohio 45226 513.612.9020

2100 North Greenville Ave. Richardson, Texas 75082 469.431.0571

THE LANDSCAPE IRRIGATION SYSTEM DESIGN OF THE DAYTON NATIONAL CEMETERY GRAVESITE EXPANSION SHALL INCLUDE EULLY FUNCTIONAL AUTOMATIC IRRIGATION INCLUDING AMENDMENT, REPLACEMENT AND REINSTALLATION OF THE ALREADY IN-PLACE EQUIPMENT AND NEW INSTALLATION CONSISTENT WITH THE ORIGINAL MANUFACTURER AND PERFORMANCE INTENT OF THE EXISTING SYSTEM.

SHEET NOTES CODE 1- MEMORIAL WALL AND COLUMBARIA

TO COMPLEMENT THE REDESIGNED AREA, THE LANDSCAPE IRRIGATION DISTRIBUTION EQUIPMENT (CONTROL VALVES, DECODERS, QUICK COUPLERS, LATERAL PIPING AND SPRINKLERS) WILL BE AMENDED TO ACCOMMODATE THE LANDSCAPE CHANGES AND ADDITIONAL COLUMBARIA SECTION. THE EXISTING IRRIGATION PRESSURE MAIN AND DECODER WIRE PATH SERVING

THE SELECTED IRRIGATION INSTALLER SHALL SALVAGE AND CATALOGUE EXISTING SURFACE-BASED IRRIGATION EQUIPMENT THAT MAY BE REMOVED FOR TURNOVER TO THE OWNER. SURFACE-BASED EQUIPMENT TO BE SALVAGED INCLUDES SERVICE BOXES, ELECTRIC AND MANUAL VALVES, DECODERS, QUICK COUPLERS AND SPRINKLERS. OBSOLETE UNDERGROUND IRRIGATION EQUIPMENT IN SECTIONS 36-42 SHALL BE ABANDONED IN-PLACE.

THE EXISTING SYSTEM A IRRIGATION SPRINKLER AND CONTROL EQUIPMENT WILL BE SPECIFIED FOR NEW INSTALLATION IN THIS AREA. THERE SHALL BE APPROXIMATELY SIX REPLACEMENT STATIONS OF TURF SPRINKLER IRRIGATION AND APPROXIMATELY THREE NEW STATIONS OF IRRIGATION TO WATER PLANTING BEDS. SPRINKLER MODELS SPECIFIED WILL BE AMENDED FROM THE ORIGINALLY INSTALLED MODELS TO INCLUDE CONTEMPORARY WATER-EFFICIENT FEATURES AND WILL BE PLACED IN THE DESIGN AREA TO COMPLIMENT THE LANDSCAPE BEING IRRIGATED.

SHEET NOTE CODE 2 NORTH PRIMARY ENTRY AND ENTRY MONUMENT

TO COMPLEMENT THE REDESIGNED AREA, THE LANDSCAPE IRRIGATION DISTRIBUTION EQUIPMENT (CONTROL VALVES, DECODERS, QUICK COUPLERS, LATERAL PIPING AND SPRINKLERS) WILL BE AMENDED TO ACCOMMODATE THE LANDSCAPE CHANGES. THE EXISTING IRRIGATION PRESSURE MAIN AND DECODER WIRE PATH SERVING THE AREA WILL BE PRESERVED FOR REUSE WHEREVER

THE SELECTED IRRIGATION INSTALLER SHALL SALVAGE AND CATALOGUE EXISTING SURFACE-BASED IRRIGATION EQUIPMENT THAT MAY BE REMOVED FOR TURNOVER TO THE OWNER. SURFACE-BASED EQUIPMENT TO BE SALVAGED INCLUDES SERVICE BOXES, ELECTRIC AND MANUAL VALVES, DECODERS, QUICK COUPLERS AND SPRINKLERS. OBSOLETE UNDERGROUND IRRIGATION EQUIPMENT IN SECTIONS 36-42 SHALL BE ABANDONED IN-PLACE.

THE EXISTING SYSTEM B IRRIGATION SPRINKLER AND CONTROL EQUIPMENT BRANDS WILL BE SPECIFIED FOR NEW INSTALLATION IN THIS AREA. THERE WILL BE APPROXIMATELY FOUR REPLACEMENT STATIONS OF TURF SPRINKLER IRRIGATION PLUS APPROXIMATELY FOUR NEW STATIONS OF IRRIGATION TO WATER PLANTING BEDS. SPRINKLER MODELS SPECIFIED WILL BE AMENDED FROM THE ORIGINALLY INSTALLED MODELS TO INCLUDE CONTEMPORARY WATER-EFFICIENT FEATURES AND WILL BE PLACED IN THE DESIGN AREA TO COMPLIMENT THE LANDSCAPE BEING IRRIGATED.

SHEET NOTES CODE 3-INGROUND CREMAINS

LOCATED ALONG THE SOUTH SIDE OF OHIO AVENUE AND WEST OF THE INTERSECTION OF PENNSYLVANIA AVENUE, A NEW AREA OF TURF IRRIGATION WILL COVER APPROXIMATELY 1.25 ACRES (NEW SECTION 45) AND 2,473 INGROUND CREMAINS. THE AREA IS ADJACENT TO ANOTHER SECTION THAT IS CONTROLLED BY SYSTEM C CONTROLLER LOCATED ON THE NORTH SIDE OF OHIO AVENUE. SYSTEM C SHALL BE DESIGNATED TO OPERATE THE NEW MP4 AREA IRRIGATION.

THE SELECTED IRRIGATION INSTALLER SHALL CONNECT NEW IRRIGATION PRESSURE PIPING AND SYSTEM C DECODER CONTROL WIRE LOCATED IN THE ADJACENT SECTION 46 AND INSTALL ALONG THE SOUTH SIDE OF OHIO AVENUE TO AREA 4 AND PROCEED TO INSTALL NEW LANDSCAPE IRRIGATION DISTRIBUTION EQUIPMENT IN THE AREA TO BE IRRIGATED.

THE EXISTING SYSTEM C IRRIGATION SPRINKLER AND CONTROL EQUIPMENT BRANDS WILL BE SPECIFIED FOR NEW INSTALLATION IN THIS AREA. THERE SHALL BE APPROXIMATELY SIX NEW TURF SPRINKLER IRRIGATION STATIONS INSTALLED AND ADDED TO SYSTEM C CONTROLLER. SPRINKLER MODELS SPECIFIED WILL INCLUDE CONTEMPORARY WATER-EFFICIENT FEATURES AND WILL BE PLACED IN THE DESIGN AREA TO COMPLIMENT THE LANDSCAPE BEING IRRIGATED.

SYSTEM C SHALL BE CONFIGURED TO ENABLE THE AREA TO BE FLOW MANAGED. THE DESIGN SHALL INCLUDE A POINT OF CONNECTION THAT SHALL DISTRIBUTE SYSTEM C PRODUCT WATER TO SYSTEM C CONTROL VALVES. THE POINT OF CONNECTION SHALL INCLUDE A THREE-INCH RAIN BIRD 300BPES MASTER VALVE IN AN APPROPRIATELY SIZED SERVICE BOX WITH TORO TW-D-1 SINGLE VALVE DECODER, BADGER DYNASONICS RS-900W POLYMER MODEL D8-C-020NAAP9SS-BMXX TWO-INCH PULSE ULTRASONIC FLOW SENSOR IN AN APPROPRIATELY SIZED SERVICE BOX WITH TORO TW-DAC-FLOW PULSE DECODER AND A QUICK COUPLER IN AN APPROPRIATELY SIZED SERVICE BOX DOWNSTREAM OF THE FLOW SENSOR ON THE SYSTEM C SUB MAINLINE.

SHEET NOTES CODE 4-SECTION 33A, TRADITIONAL BURIAL

LOCATED SOUTH OF SECTION 33, AT THE NORTHCENTRAL INTERSECTION OF MICHIGAN AVENUE AND OHIO AVENUE, NEW SECTION 33A WILL COVER APPROXIMATELY 0.30 ACRES AND INCLUDE SPACE FOR 75 SINGLE BURIAL PLOTS. THE AREA IS CURRENTLY IRRIGATED BY CONTROLLER D, A 24-VOLT CONVENTIONAL WIRE CONTROLLER LOCATED APPROXIMATELY 300 FEET TO THE NORTHWEST OF NEW SECTION 33A.

TO COMPLEMENT THE REDESIGNED AREA, THE LANDSCAPE IRRIGATION DISTRIBUTION EQUIPMENT (CONTROL VALVES, DECODERS, QUICK COUPLERS, LATERAL PIPING AND SPRINKLERS) WILL BE REPLACED.THE NEW SECTION 33A AREA WILL BE REDESIGNED TO ACCOMMODATE THE PLANNED USE. THE EXISTING IRRIGATION PRESSURE MAIN AND DECODER WIRE PATH SERVING THE AREA WILL BE PRESERVED FOR REUSE WHEREVER PRACTICAL.

THE SELECTED IRRIGATION INSTALLER SHALL SALVAGE AND CATALOGUE EXISTING SURFACE-BASED IRRIGATION EQUIPMENT THAT MAY BE REMOVED FOR TURNOVER TO THE OWNER. SURFACE-BASED EQUIPMENT TO BE SALVAGED INCLUDES SERVICE BOXES, MANUAL AND ELECTRIC VALVES, DECODERS, QUICK COUPLERS AND SPRINKLERS. OBSOLETE UNDERGROUND IRRIGATION EQUIPMENT IN NEW SECTION 33A SHALL BE ABANDONED IN-PLACE.

THE EXISTING SYSTEM D IRRIGATION SPRINKLER AND CONTROL EQUIPMENT BRANDS WILL BE SPECIFIED FOR NEW INSTALLATION IN THIS AREA. THERE WILL BE APPROXIMATELY TWO REPLACEMENT STATIONS OF TURF SPRINKLER IRRIGATION TO SERVE NEW SECTION 33A. SPRINKLER MODELS SPECIFIED WILL BE AMENDED FROM THE ORIGINALLY INSTALLED MODELS TO INCLUDE CONTEMPORARY WATER-EFFICIENT FEATURES AND WILL BE PLACED IN THE DESIGN AREA TO COMPLIMENT THE LANDSCAPE BEING IRRIGATED.

THE SELECTED IRRIGATION INSTALLER SHALL MAKE ALL TERMINAL CONNECTIONS AND TAG EACH NEW CONTROL VALVE IN ITS RESPECTIVE SERVICE BOX. THE SELECTED IRRIGATION INSTALLER SHALL NEATLY COIL THE SPARE WIRE, IDENTITY

IF SO, THE SELECTED IRRIGATION INSTALLER SHALL CONTAIN NEW REPLACEMENT 24-VOLT FIELD WIRE IN SCHEDULE 40PVC CONDUIT SIZED NOT LESS THAN 1.25—INCH, FROM THE SYSTEM D CONTROLLER TO THE NEW SECTION 33A IRRIGATION CONTROL VALVE LOCATIONS INCLUDING PULL BOXES EVERY 200 FEET. THE SELECTED IRRIGATION INSTALLER SHALL REPAIR ALL DAMAGE CAUSED BY THE INSTALLATION OF NEW 24-VOLT IRRIGATION FIELD WIRE FROM THE SYSTEM D CONTROLLER TO THE NEW SECTION

SYSTEM D SHALL BE CONFIGURED TO ENABLE THE AREA TO BE FLOW MANAGED. THE DESIGN SHALL INCLUDE A POINT OF CONNECTION THAT SHALL DISTRIBUTE SYSTEM D PRODUCT WATER TO SYSTEM D CONTROL VALVES. THE POINT OF CONNECTION SHALL INCLUDE A THREE-INCH RAIN BIRD 300BPES MASTER VALVE IN AN APPROPRIATELY SIZED SERVICE BOX WITH TORO TW-D-1 SINGLE VALVE DECODER, BADGER DYNASONICS RS-900W POLYMER MODEL D8-C-020NAAP9SS-BMXX TWO-INCH PULSE ULTRASONIC FLOW SENSOR IN AN APPROPRIATELY SIZED SERVICE BOX WITH TORO TW-DAC-FLOW PULSE DECODER AND A QUICK COUPLER IN AN APPROPRIATELY SIZED SERVICE BOX DOWNSTREAM OF THE FLOW SENSOR ON THE SYSTEM D SUB MAINLINE.

SHEET NOTES CODE 5-SECTONS 48-52 PREPLACED CRYPTS

LOCATED ALONG SOUTH GETTYSBURG AVENUE AND EAST OF KENESAW AVENUE, A NEW AREA OF IRRIGATION WILL COVER APPROXIMATELY 8.11 ACRES (NEW SECTIONS 48-52) AND 7,912 PREPLACED CRYPTS. THERE SHALL BE APPROXIMATELY 30 NEW TURF SPRINKLER IRRIGATION STATIONS INSTALLED BY THE SELECTED IRRIGATION INSTALLER. A NEW PEDESTAL-BASED IRRIGATION CONTROLLER SHALL BE INSTALLED, PROGRAMMED AND PLACED INTO SERVICE BY THE SELECTED IRRIGATION INSTALLER TO OPERATE THE NEW SPRINKLER IRRIGATION STATIONS SERVING AREA 5. THE CONTROLLER AND SYSTEM SHALL BE DESIGNATED AS SYSTEM F. SYSTEM F CONTROLLER SHALL BE SET NEAR AND SHALL DERIVE 115VOLT POWER FROM THE ELECTRIC SERVICE SERVING THE NEARBY IRRIGATION BOOSTER PUMP STATION.

SYSTEM F SHALL BE CONFIGURED TO ENABLE THE AREA TO BE FLOW MANAGED. THE DESIGN SHALL INCLUDE A POINT OF CONNECTION FROM THE NEARBY EXISTING 10-INCH IRRIGATION PIPELINE TO A SUB MAINLINE THAT SHALL DISTRIBUTE SYSTEM F PRODUCT WATER TO SYSTEM F CONTROL VALVES. THE POINT OF CONNECTION SHALL INCLUDE A FOUR-INCH MANUAL ISOLATION VALVE WITH BLOW POINT FOR WINTERIZATION, THREE-INCH RAIN BIRD 300BPES MASTER VALVE IN AN APPROPRIATELY SIZED SERVICE BOX WITH TORO TW-D-1 SINGLE VALVE DECODER, BADGER DYNASONICS RS-900W POLYMER MODEL D8-C-020NAAP9SS-BMXX TWO-INCH PULSE ULTRASONIC FLOW SENSOR IN AN APPROPRIATELY SIZED SERVICE BOX WITH TORO TW-DAC-FLOW PULSE DECODER AND A QUICK COUPLER IN AN APPROPRIATELY SIZED SERVICE BOX DOWNSTREAM OF THE FLOW SENSOR ON THE SYSTEM F SUB MAINLINE.

SHEET NOTES CODE 6-SECTIONS 36 THROUGH 42

THE REPLACEMENT EQUIPMENT INCLUDES PRESSURE PIPE, DECODER CONTROL WIRE, QUICK COUPLERS, ELECTRIC AND MANUAL VALVES AND DECODERS IN SERVICE BOXES, LATERAL PIPING AND SPRINKLER EMISSION DEVICES. THERE SHALL BE APPROXIMATELY 45 STATIONS OF REPLACEMENT IRRIGATION. THE EXISTING 24-VOLT CONVENTIONAL WIRE SYSTEM E CONTROLLER SHALL BE REPLACED WITH A NEW DECODER-BASED SYSTEM E

THE SELECTED IRRIGATION INSTALLER SHALL SALVAGE AND CATALOGUE EXISTING SURFACE-BASED IRRIGATION EQUIPMENT FOR TURNOVER TO THE OWNER. SURFACE-BASED EQUIPMENT TO BE SALVAGED INCLUDES SERVICE BOXES, MANUAL AND ELECTRIC VALVES, QUICK COUPLERS AND SPRINKLERS. OBSOLETE UNDERGROUND IRRIGATION EQUIPMENT IN SECTIONS 36-42 SHALL BE ABANDONED IN-PLACE. EXISTING IRRIGATION CORRIDORS IN SECTIONS 36-42 SHALL BE RE-UTILIZED FOR RE-INSTALLATION OF NEW REPLACEMENT IRRIGATION EQUIPMENT.

SYSTEM E SHALL BE CONFIGURED TO ENABLE THE AREA TO BE FLOW MANAGED. THE DESIGN SHALL INCLUDE A POINT OF CONNECTION THAT SHALL DISTRIBUTE SYSTEM E PRODUCT WATER TO SYSTEM D CONTROL VALVES. THE POINT OF CONNECTION SHALL INCLUDE A THREE-INCH RAIN BIRD 300BPES MASTER VALVE IN AN APPROPRIATELY SIZED SERVICE BOX WITH TORO TW-D-1 SINGLE VALVE DECODER, BADGER DYNASONICS RS-900W POLYMER MODEL D8-C-020NAAP9SS-BMXX TWO-INCH PULSE ULTRASONIC FLOW SENSOR IN AN APPROPRIATELY SIZED SERVICE BOX WITH TORO TW-DAC-FLOW PULSE DECODER AND A QUICK COUPLER IN AN APPROPRIATELY SIZED SERVICE BOX DOWNSTREAM OF THE FLOW SENSOR ON THE SYSTEM E SUB MAINLINE.

SHEET CODE 7-HAWAI PLACE FLOWER WATERING STATIONS

THE IRRIGATION SUPPLY PIPELINE ALONG HAWAII PLACE IDENTIFIED AS NON-FUNCTIONAL SHALL BE REPLACED FROM A POINT OF KNOWN OPERATION OF THE EXISTING IRRIGATION SUPPLY PIPELINE NEAR THE INTERSECTION OF WISCONSIN AVENUE/NEW MEXICO PLACE AND HAWAII PLACE AND SHALL EXTEND APPROXIMATELY 400 FEET SOUTHWEST ALONG HAWAII PLACE. THE SELECTED IRRIGATION INSTALLER SHALL RECONNECT THREE (3) FLOWER WATER STATIONS ALONG HAWAII PLACE.EXISTING OUT OF SERVICE FLOWER WATERING STATION PIPING SHALL BE ABANDONED IN PLACE.

TRACE WIRE AND WARNING TAPE SHALL BE INSTALLED ABOVE THE NEW PIPELINE FEEDING THE FLOWER WATERING STATIONS PER APPLICABLE NCA IRRIGATION PIPELINE INSTALLATION GUIDELINES. THE EXISTING IRRIGATION PIPELINE CORRIDOR ALONG HAWAII AVENUE SHALL BE RE-UTILIZED FOR RE-INSTALLATION OF THE NEW REPLACEMENT EQUIPMENT. THE SELECTED IRRIGATION INSTALLER SHALL RECONNECT

SHEET NOTES CODE 8-BOOSTER PUMP STATION AUGMENTATION

THE EXISTING IRRIGATION MUNICIPAL WATER SUPPLY AND BOOSTER PUMP STATION SHALL CONTINUE TO BE UTILIZED TO FURNISH PRODUCT WATER TO ALL LANDSCAPE IRRIGATION.

SOLE SOURCE DUTY TO BE PERFORMED BY A FACTORY AUTHORIZED WATERTRONICS SERVICING AGENT.

THE SELECTED IRRIGATION INSTALLER SHALL CONTACT MIKE GREEN OF WATERTRONICS, HARLAND, WI MIKE.GREEN@WATERTRONICS.COM, 262-337-3318 TO FACILITATE THE DISPATCHING OF A FACTORY AUTHORIZED WATERTRONICS SERVICING AGENT.

PROVIDE FOR NOT LESS THAN FIVE BUSINESS DAYS FOR A COMPLETE REVIEW, REPAIR, ADJUSTMENT, TESTING, DOCUMENTATION AND PLACEMENT INTO SERVICE OF THE EXISTING MUNICIPAL WATER IRRIGATION BOOSTER PUMP STATION PER THE MANUFACTURER PROGRAMMING AND FEATURES RECORDS. UPON VERIFICATION OF PROPER OPERATION AND BASE PROGRAMMING, ADJUST THE BOOSTER PUMP STATION PERFORMANCE AS NEEDED TO ACCOMMODATE IRRIGATION EXPANSION.

ADDITIONALLY, THE WATERTRONICS SERVICING AGENT SHALL INSTALL, PROGRAM, TEST, DOCUMENT AND PLACE INTO SERVICE:

WATERTRONICS WATERVISION PUMP STATION MONITORING HARDWARE AND SOFTWARE ONTO THE NEW IRRIGATION SYSTEM LAPTOP FURNISHED BY THE SELECTED IRRIGATION INSTALLER.

AN OPTOCOUPLER TO ENABLE SHARING OF THE BOOSTER PUMP STATION FLOW SENSOR SIGNAL AND COORDINATION WITH THE SELECTED IRRIGATION INSTALLER WHO SHALL HARDWIRE THE CONNECTION OF THE FLOW SENSOR TO NEW SATELLITE IRRIGATION CONTROLLER F USING PE-39 SIX PAIR SHIELDED TELECOM CABLE, PROPERLY GROUNDED PER MANUFACTURER RECOMMENDATIONS.

THE SELECTED IRRIGATION INSTALLER SHALL REMOVE AND DISPOSE OF THE EXISTING NON-FUNCTIONAL WALL MOUNT TORO SENTINEL RADIO-BASED BOOSTER PUMP PERFORMANCE TRANSMITTER. PROFESSIONALLY PATCH WALL PENETRATIONS AGAINST WEATHER AND INSECT INTRUSION. THE SELECTED IRRIGATION INSTALLER SHALL COORDINATE WITH THE WATERTRONICS SERVICING AGENT TO HARDWIRE THE CONNECTION OF THE FLOW SENSOR TO NEW SATELLITE IRRIGATION CONTROLLER F USING PE-39 SIX PAIR SHIELDED TELECOM CABLE PROPERLY GROUNDED PER MANUFACTURER RECOMMENDATIONS. THE SELECTED IRRIGATION INSTALLER SHALL PERFORM THE REQUIRED TORO DXI IRRIGATION DATABASE TASKS TO FULLY INTEGRATE AND ACTIVATE THE PUMP STATION FLOW SENSOR SIGNAL INTO THE TORO SENTINEL DXI IRRIGATION SOFTWARE DATABASE. SEE FIELD CONTROLLER INTERCOMMUNICATION AND CENTRAL CONTROL SECTION.

THE WATERTRONICS SERVICING AGENT SHALL FURNISH NOT LESS THAN THREE HOURS OF DETAILED BOOSTER PUMP STATION HARDWARE, SOFTWARE AND WATERVISION TRAINING TO THE OWNER’S DESIGNATED PERSONNEL. THE TRAINING SHALL INCLUDE ORIENTATION OF THE PUMP STATION COMPONENTS AND FEATURES, SEQUENCE OF OPERATION, USER INTERPHASE, STATUS INTERPRETATIONS AND RESET PROCEDURES, MALFUNCTION AND ALARM CONDITION DETECTION AND REMEDIES, USER APPROPRIATE MAINTENANCE AND CONTACT INFORMATION TO RECEIVE LIVE OFFSITE SUPPORT AND ONSITE SERVICE BY A THE RECORDING SHALL BE EDITED TO INCLUDE SEARCHABLE CHAPTERS/TOPICS AND SHALL BE DELIVERED TO THE OWNER FOR FUTURE REFERENCE AS A CONDITION OF PROJECT CLOSEOUT.MANUFACTURER-AUTHORIZED SERVICING AGENT. THE BOOSTER PUMP STATION TRAINING SHALL BE CLEAR AND UNDERSTANDABLE AND SHALL INCLUDE VIDEO AND AUDIO RECORDING.

FIELD CONTROLLER INTERCOMMUNICATION AND CENTRAL CONTROL

THE OBSOLETE IRRIGATION CONTROLS, INCLUDING THE CENTRAL COMPUTER, SOFTWARE AND FIELD CONTROLLERS SHALL BE REPLACED BY THE SELECTED IRRIGATION INSTALLER WITH NEW TORO SENTINEL DXI CELLULAR INTERNET CONNECTED REMOTE CENTRAL CONTROL HARDWARE AND SOFTWARE INCLUDING:

Signal to be relayed to Sentinel softwarel — yearTablet PCMicrosoft Surface Pro 10 for Business Intel Core Ultra 7 165U-5g—32GB RAM 256GB SSD MS Complete 2yr exchange warranty, Thunderbolt 4 Dock, Surface USB-C Travel Hub, Type Cover w/PenOr approved equal with Toro WMS software installed via free licensed installation from the Toro Company. Consult authorized Toro Sentinel Servicing Agent.One-year

THE SELECTED IRRIGATION INSTALLER SHALL CONTACT CHRIS NAGY OF THE TORO COMPANY CHRIS.NAGY@TORO.COM, 248-342-4570 TO ARRANGE FOR THE CORRECT CONFIGURATION OF THE NEW TABLET PC AND SOFTWARE REGISTRATION IN THE OWNER’S NAME INCLUDING ADMINISTRATOR AND LOWER USER CREDENTIALS, SATELLITE CONTROLLER COMMUNICATIONS AND COMMUNICATION WITH THE PUMP STATION MONITOR.

JIM LAICHE OF THE TORO COMPANY JIM.LAICHE@TORO.COM , 804-334-2225 SHALL ARRANGE FOR A FACTORY AUTHORIZED TORO SENTINEL SERVICING AGENT TO DELIVER TO DESIGNATED OWNER PERSONNEL, EXTENSIVE IRRIGATION COMPUTER CENTRAL CONTROL HARDWARE AND SOFTWARE TRAINING.

THE FACTORY AUTHORIZED TORO SENTINEL SERVICING AGENT SHALL PROVIDE FOR NOT LESS THAN FOUR BUSINESS DAYS FOR A COMPLETE REVIEW, ADJUSTMENT, TESTING, DOCUMENTATION AND PLACEMENT INTO SERVICE OF THE NEW TORO SENTINEL DXI WITH WMS REMOTE CENTRAL CONTROL SOFTWARE INCLUDING:

INSTALL ANY REQUIRED UPDATES TO THE LAPTOP FIRMWARE, DRIVERS AND OPERATING SYSTEM*

CONFIRM ADEQUATE COMMUNICATION WITH REQUIRED INTERNET RESOURCES AND FIELD DEVICES*

INSTALL, PROGRAM, TEST, DOCUMENT AND PLACE INTO SERVICE:*

TORO AUTHORIZED INTERNET-BASED WEATHER SERVICE

* ALARM CONDITION NOTIFICATIONS TO DESIGNATED OWNER REPRESENTATIVE

* SOFTWARE, COORDINATE WITH WATERTRONICS

SHARED BOOSTER PUMP FLOW SIGNAL*

FLOW SENSORS ADDED TO SUBSYSTEMS SYSTEMS C (FSC, D (FSD), E (FDE), F (FSF)*

FLOW ZONES ASSOCIATED WITH FLOW SENSORS C, D, E, F. SUBSYSTEMS A AND B SHALL HAVE FLOW DATA ASSIGNED FROM THE BOOSTER PUMP STATION SHARED FLOW SIGNAL.

* FLOW TESTING AND DATA ENTRY FOR ALL IRRIGATION STATIONS.

FLOW WATCH FOR ALL IRRIGATION STATIONS HIGH AND LOW FLOW ALARM NOTIFICATIONS*

* FLOW OPTOMIZATION OF IRRIGATION SCHEDULES

* SELECTABLE WEATHER-BASED IRRIGATION SCHEDULES

SELECTABLE FIXED IRRIGATION SCHEDULES*

FURNISH AND DOCUMENT NOT LESS THAN FOUR HOURS OF TRAINING TO THE OWNER OF TORO SENTINEL REMOTE CONTROL SOFTWARE, BASIC THROUGH ADVANCED, TRAINING IN THE INSTALLATION AND USE OF THE CELLULAR PHONE/FIELD TABLET APPLICATION, ADMINISTRATOR TRAINING IN THE ASSIGNMENT AND REVOCATION OF SUBORDINATE USER PRIVILEGES.*

THE RECORDING SHALL BE EDITED TO INCLUDE SEARCHABLE CHAPTERS/TOPICS AND SHALL BE DELIVERED TO THE OWNER FOR FUTURE REFERENCE AS A CONDITION OF PROJECT CLOSEOUT.THE IRRIGATION COMPUTER CENTRAL CONTROL HARDWARE AND SOFTWARE TRAINING SHALL BE CLEARLY AND UNDERSTANDABLY VIDEO AND AUDIO RECORDED.

swgation 2 , _ O. IRRIGATION GENERAL DIRECTION6 6o

ANDERSON CID2

7A IR100VA

LOCATED AT THE INTERSECTION OF WEST THIRD AVENUE AND WISCONSIN AVENUE, THE NORTH PRIMARY ENTRY TO THE CEMETERY IS CURRENTLY IRRIGATED BY FOUR STATIONS OF TURF SPRINKLERS CONTROLLED BY THE SYSTEM B CONTROLLER.

PRACTICAL.

THE REPLACEMENT PIPELINE AND FITTINGS ALONG HAWAII PLACE SHALL BE OF HDPE SDR11 CLASS 200 BUTT FUSE WELD POLYETHYLENE AND SHALL BE ASSOCIATED TO SYSTEM B CONTROLLER PRESSURE PIPELINE.

THREE (3) FLOWER WATERING STATIONS ALONG HAWAII PLACE.

cell service, two year equipment warrantyTablet PC Bump Case URBAN ARMOR GEAR UAG Designed for Microsoft Surface Pro 10 Case with Built-in Kickstand Hand & Shoulder Strap Pen Holder Compatible with Type Cover Keyboard Or approved equall-year THE SELECTED IRRIGATION INSTALLER SHALL INSTALL AND CONNECT ALL IRRIGATION CONTROLLERS, TEST, TROUBLESHOOT, PLACE INTO SERVICE AND ENTER BASIC IRRIGATION STATION DATA AND IRRIGATION SCHEDULES THAT ENABLE COORDINATED IRRIGATION OPERATIONS WITHIN 10-HOUR WATER WINDOWS AND WITHOUT HYDRAULIC OVERLOADING INCLUDING AVOIDANCE OF EXCEEDING FIVE FEET PER SECOND WATER VELOCITY THROUGH PIPES AND AVOIDING EXCEEDING WATER SUPPLY CAPABILITY OF THE MUNICIPAL IRRIGATION BOOSTER PUMP STATION.

IT REMAINS UNCLEAR IF THE EXISTING SYSTEM D CONVENTIONAL 24-VOLT FIELD WIRE IS CONTAINED IN CONDUIT.

33A IRRIGATION CONTROL VALVE LOCATIONS.

LOCATED AT THE NORTHWEST AREA OF THE CEMETERY, SOUTH OF WEST THIRD STREET AND NORTH OF MCMAHON AVENUE, THIS RE-DESIGN AREA IS CURRENTLY IRRIGATED BY SIX STATIONS OF TURF SPRINKLERS CONTROLLED BY THE SYSTEM A CONTROLLER.

THE AREA WILL BE PRESERVED FOR REUSE WHEREVER PRACTICAL.

THE NON-FUNCTIONAL AND OBSOLETE IRRIGATION EQUIPMENT IN SECTIONS 36-42 IS RE-DESIGNED AND SPECIFIED FOR RE-INSTALLATION BY THE SELECTED IRRIGATION INSTALLER.

CONTROLLER CONSISTENT WITH ALL OTHER CONTROLLERS (SEE THE FIELD CONTROLLER INTERCOMMUNICATION AND CENTRAL CONTROL SECTION BELOW).

CONFIRM HARDWARE AND SOFTWARE WARRANTY AND SUPPORT REGISTRATION WITH TORO NATIONAL SERVICE NETWORK (NSN)

ENTER ADMINISTRATOR AND SUBORDINATE USER PRIVILEGES DESIGNATED BY THE OWNER

AVAILABLE INTEGRATION(S) WITH THE WATERTRONICS WATERVISION PUMP MONITORING

TIPPING RAIN BUCKET

CELLULAR PHONE/FIELD TABLET-BASED REMOTE-CONTROL APPLICATION

OTHER FEATURES AND/OR SERVICES THAT WILL MAXIMIZE THE OWNER’S EFFICIENT USE OF THE TORO SENTINEL REMOTE CONTROL HARDWARE AND SOFTWARE.

PROGRAM, TEST, DOCUMENT AND PLACE INTO SERVICE:

SHOULD NEW 24-VOLT FIELD WIRE BE REQUIRED TO OPERATE THE NEW REPLACEMENT SECTION 33A IRRIGATION FIELD CONTROLS, THE SELECTED IRRIGATION INSTALLER SHALL INSTALL THE APPROXIMATELY TWO 24-VOLT FIELD WIRES, A COMMON WIRE AND ONE SPARE SIGNAL WIRE FROM THE SYSTEM D CONTROLLER TO THE NEW SECTION 33A IRRIGATION CONTROL VALVE LOCATIONS.

TAG THE WIRE AT BOTH ENDS PLACING ONE END IN ONE OF THE TWO NEW CONTROL VALVE SURFACE BOXES AND THE OTHER END PLACED NEATLY INSIDE THE SYSTEM D CONTROL CABINET.

CONTROLLERSPECIFIED MODELTYPECell SERVICE & HDWR WARRANTYMASTER VALVEFLOW SENSORController A (decoder controller)DXi-PPED-TW-M8C DXi-CELL-KIT DXi-FMW-WMS 5Y-EXT-WARRANTYDecoder 200 stationsi0—yearNONEBooster pump station shared flow signalcontroller B (decoder controller)DXi—PPED-TW-M8C DXi-CELL-KIT DXi-FMW-WMS 5Y-EXT-WARRANTYDecoder 200 stationsi 0—yearNONEBooster pump station shared flow signalcontroller C (decoder controller)DXi-PPED-TW-M8C DXi-CELL-KIT DXi-FMW-WMS 5Y-EXT-WARRANTYDecoder 200 stationsi0-yearRAIN BIRD 300BPES with TORO TW-D-1 DecoderBadger Dynasonics RS-900W MODEL D8-C-020NAAP9SS-BMXX with Toro TW-DAC-FLOW DecoderController D (conventional controller) DXi-PWM —48—M80 DXi-CELL-KIT DXi-FMW-WMS 5Y-EXT-WARRANTY24—volt 48 stationsi0-yearRAIN BIRD 300BPES with TORO TW-D-1 DecoderBadger Dynasonics RS-900W MODEL D8-C-020NAAP9SS-BMXX with Toro TW-DAC-FLOW DecoderController E (decoder controller)DXi-PPED-TW-M8C DXi-CELL-KIT DXi-FMW-WMS 5Y-EXT-WARRANTYDecoder 200 stationsi 0—yearRAIN BIRD 300BPES with TORO TW-D-1 DecoderBadger Dynasonics RS-900W MODEL D8-C-020NAAP9SS-BMXX with Toro TW-DAC-FLOW DecoderController F (decoder controller)DXi-PPED-TW-M8C DXi-CELL-KIT DXi-FMW-WMS 5Y-EXT-WARRANTYDecoder 200 stationsi0—yearRAIN BIRD 300BPES with TORO TW—D —1 DecoderBadger Dynasonics RS-900W MODEL D8—C-020NAAP9SS—BMXX with Toro TW-DAC—FLOW DecoderRain CanTexas Instruments TR — 525IUse pulse decoder. Connect to Controller F.

<0

T EPA

Timothy R. Malooly CID, CIC, CLIA #012894

Water Sense

2008 PARTNER

Je

C,, < 'ON AsSO

AutoCAD SHX Text

IRRIGATION GENERAL DIRECTION

AutoCAD SHX Text

IR100

AutoCAD SHX Text THE LANDSCAPE IRRIGATION SYSTEM DESIGN OF THE DAYTON NATIONAL CEMETERY GRAVESITE EXPANSION SHALL INCLUDE FULLY FUNCTIONAL AUTOMATIC IRRIGATION INCLUDING AMENDMENT, REPLACEMENT AND REINSTALLATION OF THE ALREADY IN-PLACE EQUIPMENT AND NEW INSTALLATION CONSISTENT WITH THE ORIGINAL MANUFACTURER AND PERFORMANCE INTENT OF THE EXISTING SYSTEM. SHEET NOTES CODE 1- MEMORIAL WALL AND COLUMBARIA LOCATED AT THE NORTHWEST AREA OF THE CEMETERY, SOUTH OF WEST THIRD STREET AND NORTH OF MCMAHON AVENUE, THIS RE-DESIGN AREA IS CURRENTLY IRRIGATED BY SIX STATIONS OF TURF SPRINKLERS CONTROLLED BY THE SYSTEM A CONTROLLER. TO COMPLEMENT THE REDESIGNED AREA, THE LANDSCAPE IRRIGATION DISTRIBUTION EQUIPMENT (CONTROL VALVES, DECODERS, QUICK COUPLERS, LATERAL PIPING AND SPRINKLERS) WILL BE AMENDED TO ACCOMMODATE THE LANDSCAPE CHANGES AND ADDITIONAL COLUMBARIA SECTION. THE EXISTING IRRIGATION PRESSURE MAIN AND DECODER WIRE PATH SERVING THE AREA WILL BE PRESERVED FOR REUSE WHEREVER PRACTICAL. THE SELECTED IRRIGATION INSTALLER SHALL SALVAGE AND CATALOGUE EXISTING SURFACE-BASED IRRIGATION EQUIPMENT THAT MAY BE REMOVED FOR TURNOVER TO THE OWNER. SURFACE-BASED EQUIPMENT TO BE SALVAGED INCLUDES SERVICE BOXES, ELECTRIC AND MANUAL VALVES, DECODERS, QUICK COUPLERS AND SPRINKLERS. OBSOLETE UNDERGROUND IRRIGATION EQUIPMENT IN SECTIONS 36-42 SHALL BE ABANDONED IN-PLACE. THE EXISTING SYSTEM A IRRIGATION SPRINKLER AND CONTROL EQUIPMENT WILL BE SPECIFIED FOR NEW INSTALLATION IN THIS AREA. THERE SHALL BE APPROXIMATELY SIX REPLACEMENT STATIONS OF TURF SPRINKLER IRRIGATION AND APPROXIMATELY THREE NEW STATIONS OF IRRIGATION TO WATER PLANTING BEDS. SPRINKLER MODELS SPECIFIED WILL BE AMENDED FROM THE ORIGINALLY INSTALLED MODELS TO INCLUDE CONTEMPORARY WATER-EFFICIENT FEATURES AND WILL BE PLACED IN THE DESIGN AREA TO COMPLIMENT THE LANDSCAPE BEING IRRIGATED. SHEET NOTE CODE 2- NORTH PRIMARY ENTRY AND ENTRY MONUMENT LOCATED AT THE INTERSECTION OF WEST THIRD AVENUE AND WISCONSIN AVENUE, THE NORTH PRIMARY ENTRY TO THE CEMETERY IS CURRENTLY IRRIGATED BY FOUR STATIONS OF TURF SPRINKLERS CONTROLLED BY THE SYSTEM B CONTROLLER. TO COMPLEMENT THE REDESIGNED AREA, THE LANDSCAPE IRRIGATION DISTRIBUTION EQUIPMENT (CONTROL VALVES, DECODERS, QUICK COUPLERS, LATERAL PIPING AND SPRINKLERS) WILL BE AMENDED TO ACCOMMODATE THE LANDSCAPE CHANGES. THE EXISTING IRRIGATION PRESSURE MAIN AND DECODER WIRE PATH SERVING THE AREA WILL BE PRESERVED FOR REUSE WHEREVER PRACTICAL. THE SELECTED IRRIGATION INSTALLER SHALL SALVAGE AND CATALOGUE EXISTING SURFACE-BASED IRRIGATION EQUIPMENT THAT MAY BE REMOVED FOR TURNOVER TO THE OWNER. SURFACE-BASED EQUIPMENT TO BE SALVAGED INCLUDES SERVICE BOXES, ELECTRIC AND MANUAL VALVES, DECODERS, QUICK COUPLERS AND SPRINKLERS. OBSOLETE UNDERGROUND IRRIGATION EQUIPMENT IN SECTIONS 36-42 SHALL BE ABANDONED IN-PLACE. THE EXISTING SYSTEM B IRRIGATION SPRINKLER AND CONTROL EQUIPMENT BRANDS WILL BE SPECIFIED FOR NEW INSTALLATION IN THIS AREA. THERE WILL BE APPROXIMATELY FOUR REPLACEMENT STATIONS OF TURF SPRINKLER IRRIGATION PLUS APPROXIMATELY FOUR NEW STATIONS OF IRRIGATION TO WATER PLANTING BEDS. SPRINKLER MODELS SPECIFIED WILL BE AMENDED FROM THE ORIGINALLY INSTALLED MODELS TO INCLUDE CONTEMPORARY WATER-EFFICIENT FEATURES AND WILL BE PLACED IN THE DESIGN AREA TO COMPLIMENT THE LANDSCAPE BEING IRRIGATED. SHEET NOTES CODE 3-INGROUND CREMAINS LOCATED ALONG THE SOUTH SIDE OF OHIO AVENUE AND WEST OF THE INTERSECTION OF PENNSYLVANIA AVENUE, A NEW AREA OF TURF IRRIGATION WILL COVER APPROXIMATELY 1.25 ACRES (NEW SECTION 45) AND 2,473 INGROUND CREMAINS. THE AREA IS ADJACENT TO ANOTHER SECTION THAT IS CONTROLLED BY SYSTEM C CONTROLLER LOCATED ON THE NORTH SIDE OF OHIO AVENUE. SYSTEM C SHALL BE DESIGNATED TO OPERATE THE NEW MP4 AREA IRRIGATION. THE SELECTED IRRIGATION INSTALLER SHALL CONNECT NEW IRRIGATION PRESSURE PIPING AND SYSTEM C DECODER CONTROL WIRE LOCATED IN THE ADJACENT SECTION 46 AND INSTALL ALONG THE SOUTH SIDE OF OHIO AVENUE TO AREA 4 AND PROCEED TO INSTALL NEW LANDSCAPE IRRIGATION DISTRIBUTION EQUIPMENT IN THE AREA TO BE IRRIGATED. THE EXISTING SYSTEM C IRRIGATION SPRINKLER AND CONTROL EQUIPMENT BRANDS WILL BE SPECIFIED FOR NEW INSTALLATION IN THIS AREA. THERE SHALL BE APPROXIMATELY SIX NEW TURF SPRINKLER IRRIGATION STATIONS INSTALLED AND ADDED TO SYSTEM C CONTROLLER. SPRINKLER MODELS SPECIFIED WILL INCLUDE CONTEMPORARY WATER-EFFICIENT FEATURES AND WILL BE PLACED IN THE DESIGN AREA TO COMPLIMENT THE LANDSCAPE BEING IRRIGATED. SYSTEM C SHALL BE CONFIGURED TO ENABLE THE AREA TO BE FLOW MANAGED. THE DESIGN SHALL INCLUDE A POINT OF CONNECTION THAT SHALL DISTRIBUTE SYSTEM C PRODUCT WATER TO SYSTEM C CONTROL VALVES. THE POINT OF CONNECTION SHALL INCLUDE A THREE-INCH RAIN BIRD 300BPES MASTER VALVE IN AN APPROPRIATELY SIZED SERVICE BOX WITH TORO TW-D-1 SINGLE VALVE DECODER, BADGER DYNASONICS RS-900W POLYMER MODEL D8-C-020NAAP9SS-BMXX TWO-INCH PULSE ULTRASONIC FLOW SENSOR IN AN APPROPRIATELY SIZED SERVICE BOX WITH TORO TW-DAC-FLOW PULSE DECODER AND A QUICK COUPLER IN AN APPROPRIATELY SIZED SERVICE BOX DOWNSTREAM OF THE FLOW SENSOR ON THE SYSTEM C SUB MAINLINE. SHEET NOTES CODE 4-SECTION 33A, TRADITIONAL BURIAL LOCATED SOUTH OF SECTION 33, AT THE NORTHCENTRAL INTERSECTION OF MICHIGAN AVENUE AND OHIO AVENUE, NEW SECTION 33A WILL COVER APPROXIMATELY 0.30 ACRES AND INCLUDE SPACE FOR 75 SINGLE BURIAL PLOTS. THE AREA IS CURRENTLY IRRIGATED BY CONTROLLER D, A 24-VOLT CONVENTIONAL WIRE CONTROLLER LOCATED APPROXIMATELY 300 FEET TO THE NORTHWEST OF NEW SECTION 33A. THE NEW SECTION 33A AREA WILL BE REDESIGNED TO ACCOMMODATE THE PLANNED USE. TO COMPLEMENT THE REDESIGNED AREA, THE LANDSCAPE IRRIGATION DISTRIBUTION EQUIPMENT (CONTROL VALVES, DECODERS, QUICK COUPLERS, LATERAL PIPING AND SPRINKLERS) WILL BE REPLACED. THE EXISTING IRRIGATION PRESSURE MAIN AND DECODER WIRE PATH SERVING THE AREA WILL BE PRESERVED FOR REUSE WHEREVER PRACTICAL. THE SELECTED IRRIGATION INSTALLER SHALL SALVAGE AND CATALOGUE EXISTING SURFACE-BASED IRRIGATION EQUIPMENT THAT MAY BE REMOVED FOR TURNOVER TO THE OWNER. SURFACE-BASED EQUIPMENT TO BE SALVAGED INCLUDES SERVICE BOXES, MANUAL AND ELECTRIC VALVES, DECODERS, QUICK COUPLERS AND SPRINKLERS. OBSOLETE UNDERGROUND IRRIGATION EQUIPMENT IN NEW SECTION 33A SHALL BE ABANDONED IN-PLACE. THE EXISTING SYSTEM D IRRIGATION SPRINKLER AND CONTROL EQUIPMENT BRANDS WILL BE SPECIFIED FOR NEW INSTALLATION IN THIS AREA. THERE WILL BE APPROXIMATELY TWO REPLACEMENT STATIONS OF TURF SPRINKLER IRRIGATION TO SERVE NEW SECTION 33A. SPRINKLER MODELS SPECIFIED WILL BE AMENDED FROM THE ORIGINALLY INSTALLED MODELS TO INCLUDE CONTEMPORARY WATER-EFFICIENT FEATURES AND WILL BE PLACED IN THE DESIGN AREA TO COMPLIMENT THE LANDSCAPE BEING IRRIGATED. SHOULD NEW 24-VOLT FIELD WIRE BE REQUIRED TO OPERATE THE NEW REPLACEMENT SECTION 33A IRRIGATION FIELD CONTROLS, THE SELECTED IRRIGATION INSTALLER SHALL INSTALL THE APPROXIMATELY TWO 24-VOLT FIELD WIRES, A COMMON WIRE AND ONE SPARE SIGNAL WIRE FROM THE SYSTEM D CONTROLLER TO THE NEW SECTION 33A IRRIGATION CONTROL VALVE LOCATIONS. THE SELECTED IRRIGATION INSTALLER SHALL MAKE ALL TERMINAL CONNECTIONS AND TAG EACH NEW CONTROL VALVE IN ITS RESPECTIVE SERVICE BOX. THE SELECTED IRRIGATION INSTALLER SHALL NEATLY COIL THE SPARE WIRE, IDENTITY TAG THE WIRE AT BOTH ENDS PLACING ONE END IN ONE OF THE TWO NEW CONTROL VALVE SURFACE BOXES AND THE OTHER END PLACED NEATLY INSIDE THE SYSTEM D CONTROL CABINET. IT REMAINS UNCLEAR IF THE EXISTING SYSTEM D CONVENTIONAL 24-VOLT FIELD WIRE IS CONTAINED IN CONDUIT. IF SO, THE SELECTED IRRIGATION INSTALLER SHALL CONTAIN NEW REPLACEMENT 24-VOLT FIELD WIRE IN SCHEDULE 40PVC CONDUIT SIZED NOT LESS THAN 1.25-INCH, FROM THE SYSTEM D CONTROLLER TO THE NEW SECTION 33A IRRIGATION CONTROL VALVE LOCATIONS INCLUDING PULL BOXES EVERY 200 FEET. THE SELECTED IRRIGATION INSTALLER SHALL REPAIR ALL DAMAGE CAUSED BY THE INSTALLATION OF NEW 24-VOLT IRRIGATION FIELD WIRE FROM THE SYSTEM D CONTROLLER TO THE NEW SECTION 33A IRRIGATION CONTROL VALVE LOCATIONS. SYSTEM D SHALL BE CONFIGURED TO ENABLE THE AREA TO BE FLOW MANAGED. THE DESIGN SHALL INCLUDE A POINT OF CONNECTION THAT SHALL DISTRIBUTE SYSTEM D PRODUCT WATER TO SYSTEM D CONTROL VALVES. THE POINT OF CONNECTION SHALL INCLUDE A THREE-INCH RAIN BIRD 300BPES MASTER VALVE IN AN APPROPRIATELY SIZED SERVICE BOX WITH TORO TW-D-1 SINGLE VALVE DECODER, BADGER DYNASONICS RS-900W POLYMER MODEL D8-C-020NAAP9SS-BMXX TWO-INCH PULSE ULTRASONIC FLOW SENSOR IN AN APPROPRIATELY SIZED SERVICE BOX WITH TORO TW-DAC-FLOW PULSE DECODER AND A QUICK COUPLER IN AN APPROPRIATELY SIZED SERVICE BOX DOWNSTREAM OF THE FLOW SENSOR ON THE SYSTEM D SUB MAINLINE. SHEET NOTES CODE 5-SECTONS 48-52 PREPLACED CRYPTS LOCATED ALONG SOUTH GETTYSBURG AVENUE AND EAST OF KENESAW AVENUE, A NEW AREA OF IRRIGATION WILL COVER APPROXIMATELY 8.11 ACRES (NEW SECTIONS 48-52) AND 7,912 PREPLACED CRYPTS. THERE SHALL BE APPROXIMATELY 30 NEW TURF SPRINKLER IRRIGATION STATIONS INSTALLED BY THE SELECTED IRRIGATION INSTALLER. A NEW PEDESTAL-BASED IRRIGATION CONTROLLER SHALL BE INSTALLED, PROGRAMMED AND PLACED INTO SERVICE BY THE SELECTED IRRIGATION INSTALLER TO OPERATE THE NEW SPRINKLER IRRIGATION STATIONS SERVING AREA 5. THE CONTROLLER AND SYSTEM SHALL BE DESIGNATED AS SYSTEM F. SYSTEM F CONTROLLER SHALL BE SET NEAR AND SHALL DERIVE 115VOLT POWER FROM THE ELECTRIC SERVICE SERVING THE NEARBY IRRIGATION BOOSTER PUMP STATION. SYSTEM F SHALL BE CONFIGURED TO ENABLE THE AREA TO BE FLOW MANAGED. THE DESIGN SHALL INCLUDE A POINT OF CONNECTION FROM THE NEARBY EXISTING 10-INCH IRRIGATION PIPELINE TO A SUB MAINLINE THAT SHALL DISTRIBUTE SYSTEM F PRODUCT WATER TO SYSTEM F CONTROL VALVES. THE POINT OF CONNECTION SHALL INCLUDE A FOUR-INCH MANUAL ISOLATION VALVE WITH BLOW POINT FOR WINTERIZATION, THREE-INCH RAIN BIRD 300BPES MASTER VALVE IN AN APPROPRIATELY SIZED SERVICE BOX WITH TORO TW-D-1 SINGLE VALVE DECODER, BADGER DYNASONICS RS-900W POLYMER MODEL D8-C-020NAAP9SS-BMXX TWO-INCH PULSE ULTRASONIC FLOW SENSOR IN AN APPROPRIATELY SIZED SERVICE BOX WITH TORO TW-DAC-FLOW PULSE DECODER AND A QUICK COUPLER IN AN APPROPRIATELY SIZED SERVICE BOX DOWNSTREAM OF THE FLOW SENSOR ON THE SYSTEM F SUB MAINLINE. SHEET NOTES CODE 6-SECTIONS 36 THROUGH 42 THE NON-FUNCTIONAL AND OBSOLETE IRRIGATION EQUIPMENT IN SECTIONS 36-42 IS RE-DESIGNED AND SPECIFIED FOR RE-INSTALLATION BY THE SELECTED IRRIGATION INSTALLER. THE REPLACEMENT EQUIPMENT INCLUDES PRESSURE PIPE, DECODER CONTROL WIRE, QUICK COUPLERS, ELECTRIC AND MANUAL VALVES AND DECODERS IN SERVICE BOXES, LATERAL PIPING AND SPRINKLER EMISSION DEVICES. THERE SHALL BE APPROXIMATELY 45 STATIONS OF REPLACEMENT IRRIGATION. THE EXISTING 24-VOLT CONVENTIONAL WIRE SYSTEM E CONTROLLER SHALL BE REPLACED WITH A NEW DECODER-BASED SYSTEM E CONTROLLER CONSISTENT WITH ALL OTHER CONTROLLERS (SEE THE FIELD CONTROLLER INTERCOMMUNICATION AND CENTRAL CONTROL SECTION BELOW). FIELD CONTROLLER INTERCOMMUNICATION AND CENTRAL CONTROL SECTION BELOW). SECTION BELOW). THE SELECTED IRRIGATION INSTALLER SHALL SALVAGE AND CATALOGUE EXISTING SURFACE-BASED IRRIGATION EQUIPMENT FOR TURNOVER TO THE OWNER. SURFACE-BASED EQUIPMENT TO BE SALVAGED INCLUDES SERVICE BOXES, MANUAL AND ELECTRIC VALVES, QUICK COUPLERS AND SPRINKLERS. OBSOLETE UNDERGROUND IRRIGATION EQUIPMENT IN SECTIONS 36-42 SHALL BE ABANDONED IN-PLACE. EXISTING IRRIGATION CORRIDORS IN SECTIONS 36-42 SHALL BE RE-UTILIZED FOR RE-INSTALLATION OF NEW REPLACEMENT IRRIGATION EQUIPMENT. SYSTEM E SHALL BE CONFIGURED TO ENABLE THE AREA TO BE FLOW MANAGED. THE DESIGN SHALL INCLUDE A POINT OF CONNECTION THAT SHALL DISTRIBUTE SYSTEM E PRODUCT WATER TO SYSTEM D CONTROL VALVES. THE POINT OF CONNECTION SHALL INCLUDE A THREE-INCH RAIN BIRD 300BPES MASTER VALVE IN AN APPROPRIATELY SIZED SERVICE BOX WITH TORO TW-D-1 SINGLE VALVE DECODER, BADGER DYNASONICS RS-900W POLYMER MODEL D8-C-020NAAP9SS-BMXX TWO-INCH PULSE ULTRASONIC FLOW SENSOR IN AN APPROPRIATELY SIZED SERVICE BOX WITH TORO TW-DAC-FLOW PULSE DECODER AND A QUICK COUPLER IN AN APPROPRIATELY SIZED SERVICE BOX DOWNSTREAM OF THE FLOW SENSOR ON THE SYSTEM E SUB MAINLINE. SHEET CODE 7-HAWAII PLACE FLOWER WATERING STATIONS THE IRRIGATION SUPPLY PIPELINE ALONG HAWAII PLACE IDENTIFIED AS NON-FUNCTIONAL SHALL BE REPLACED FROM A POINT OF KNOWN OPERATION OF THE EXISTING IRRIGATION SUPPLY PIPELINE NEAR THE INTERSECTION OF WISCONSIN AVENUE/NEW MEXICO PLACE AND HAWAII PLACE AND SHALL EXTEND APPROXIMATELY 400 FEET SOUTHWEST ALONG HAWAII PLACE. EXISTING OUT OF SERVICE FLOWER WATERING STATION PIPING SHALL BE ABANDONED IN PLACE. THE SELECTED IRRIGATION INSTALLER SHALL RECONNECT THREE (3) FLOWER WATER STATIONS ALONG HAWAII PLACE. THE REPLACEMENT PIPELINE AND FITTINGS ALONG HAWAII PLACE SHALL BE OF HDPE SDR11 CLASS 200 BUTT FUSE WELD POLYETHYLENE AND SHALL BE ASSOCIATED TO SYSTEM B CONTROLLER PRESSURE PIPELINE. TRACE WIRE AND WARNING TAPE SHALL BE INSTALLED ABOVE THE NEW PIPELINE FEEDING THE FLOWER WATERING STATIONS PER APPLICABLE NCA IRRIGATION PIPELINE INSTALLATION GUIDELINES. THE EXISTING IRRIGATION PIPELINE CORRIDOR ALONG HAWAII AVENUE SHALL BE RE-UTILIZED FOR RE-INSTALLATION OF THE NEW REPLACEMENT EQUIPMENT. THE SELECTED IRRIGATION INSTALLER SHALL RECONNECT THREE (3) FLOWER WATERING STATIONS ALONG HAWAII PLACE. SHEET NOTES CODE 8-BOOSTER PUMP STATION AUGMENTATION THE EXISTING IRRIGATION MUNICIPAL WATER SUPPLY AND BOOSTER PUMP STATION SHALL CONTINUE TO BE UTILIZED TO FURNISH PRODUCT WATER TO ALL LANDSCAPE IRRIGATION. SOLE SOURCE DUTY TO BE PERFORMED BY A FACTORY AUTHORIZED WATERTRONICS SERVICING AGENT. THE SELECTED IRRIGATION INSTALLER SHALL CONTACT MIKE GREEN OF WATERTRONICS, HARLAND, WI MIKE.GREEN@WATERTRONICS.COM, 262-337-3318 TO FACILITATE THE DISPATCHING OF A FACTORY AUTHORIZED WATERTRONICS SERVICING AGENT. MIKE.GREEN@WATERTRONICS.COM, 262-337-3318 TO FACILITATE THE DISPATCHING OF A FACTORY AUTHORIZED WATERTRONICS SERVICING AGENT. , 262-337-3318 TO FACILITATE THE DISPATCHING OF A FACTORY AUTHORIZED WATERTRONICS SERVICING AGENT. PROVIDE FOR NOT LESS THAN FIVE BUSINESS DAYS FOR A COMPLETE REVIEW, REPAIR, ADJUSTMENT, TESTING, DOCUMENTATION AND PLACEMENT INTO SERVICE OF THE EXISTING MUNICIPAL WATER IRRIGATION BOOSTER PUMP STATION PER THE MANUFACTURER PROGRAMMING AND FEATURES RECORDS. UPON VERIFICATION OF PROPER OPERATION AND BASE PROGRAMMING, ADJUST THE BOOSTER PUMP STATION PERFORMANCE AS NEEDED TO ACCOMMODATE IRRIGATION EXPANSION. ADDITIONALLY, THE WATERTRONICS SERVICING AGENT SHALL INSTALL, PROGRAM, TEST, DOCUMENT AND PLACE INTO SERVICE: WATERTRONICS WATERVISION PUMP STATION MONITORING HARDWARE AND SOFTWARE ONTO THE NEW IRRIGATION SYSTEM LAPTOP FURNISHED BY THE SELECTED IRRIGATION INSTALLER. AN OPTOCOUPLER TO ENABLE SHARING OF THE BOOSTER PUMP STATION FLOW SENSOR SIGNAL AND COORDINATION WITH THE SELECTED IRRIGATION INSTALLER WHO SHALL HARDWIRE THE CONNECTION OF THE FLOW SENSOR TO NEW SATELLITE IRRIGATION CONTROLLER F USING PE-39 SIX PAIR SHIELDED TELECOM CABLE, PROPERLY GROUNDED PER MANUFACTURER RECOMMENDATIONS. THE SELECTED IRRIGATION INSTALLER SHALL REMOVE AND DISPOSE OF THE EXISTING NON-FUNCTIONAL WALL MOUNT TORO SENTINEL® RADIO-BASED BOOSTER PUMP PERFORMANCE TRANSMITTER. PROFESSIONALLY PATCH WALL PENETRATIONS AGAINST WEATHER AND INSECT INTRUSION. THE SELECTED IRRIGATION INSTALLER SHALL COORDINATE WITH THE WATERTRONICS SERVICING AGENT TO HARDWIRE THE CONNECTION OF THE FLOW SENSOR TO NEW SATELLITE IRRIGATION CONTROLLER F USING PE-39 SIX PAIR SHIELDED TELECOM CABLE PROPERLY GROUNDED PER MANUFACTURER RECOMMENDATIONS. THE SELECTED RADIO-BASED BOOSTER PUMP PERFORMANCE TRANSMITTER. PROFESSIONALLY PATCH WALL PENETRATIONS AGAINST WEATHER AND INSECT INTRUSION. THE SELECTED IRRIGATION INSTALLER SHALL COORDINATE WITH THE WATERTRONICS SERVICING AGENT TO HARDWIRE THE CONNECTION OF THE FLOW SENSOR TO NEW SATELLITE IRRIGATION CONTROLLER F USING PE-39 SIX PAIR SHIELDED TELECOM CABLE PROPERLY GROUNDED PER MANUFACTURER RECOMMENDATIONS. THE SELECTED IRRIGATION INSTALLER SHALL PERFORM THE REQUIRED TORO DXI IRRIGATION DATABASE TASKS TO FULLY INTEGRATE AND ACTIVATE THE PUMP STATION FLOW SENSOR SIGNAL INTO THE TORO SENTINEL DXI IRRIGATION SOFTWARE DATABASE. SEE FIELD CONTROLLER INTERCOMMUNICATION AND CENTRAL CONTROL SECTION. THE WATERTRONICS SERVICING AGENT SHALL FURNISH NOT LESS THAN THREE HOURS OF DETAILED BOOSTER PUMP STATION HARDWARE, SOFTWARE AND WATERVISION TRAINING TO THE OWNER'S DESIGNATED PERSONNEL. THE TRAINING SHALL INCLUDE ORIENTATION OF THE PUMP STATION COMPONENTS AND FEATURES, SEQUENCE OF OPERATION, USER INTERPHASE, STATUS INTERPRETATIONS AND RESET PROCEDURES, MALFUNCTION AND ALARM CONDITION DETECTION AND REMEDIES, USER APPROPRIATE MAINTENANCE AND CONTACT INFORMATION TO RECEIVE LIVE OFFSITE SUPPORT AND ONSITE SERVICE BY A MANUFACTURER-AUTHORIZED SERVICING AGENT. THE BOOSTER PUMP STATION TRAINING SHALL BE CLEAR AND UNDERSTANDABLE AND SHALL INCLUDE VIDEO AND AUDIO RECORDING. THE RECORDING SHALL BE EDITED TO INCLUDE SEARCHABLE CHAPTERS/TOPICS AND SHALL BE DELIVERED TO THE OWNER FOR FUTURE REFERENCE AS A CONDITION OF PROJECT CLOSEOUT. FIELD CONTROLLER INTERCOMMUNICATION AND CENTRAL CONTROL THE OBSOLETE IRRIGATION CONTROLS, INCLUDING THE CENTRAL COMPUTER, SOFTWARE AND FIELD CONTROLLERS SHALL BE REPLACED BY THE SELECTED IRRIGATION INSTALLER WITH NEW TORO SENTINEL DXI CELLULAR INTERNET CONNECTED REMOTE CENTRAL CONTROL HARDWARE AND SOFTWARE INCLUDING: CONTROLLERSPECIFIED MODELTYPECell SERVICE & HDWR WARRANTYMASTER VALVEFLOW SENSORController A (decoder controller)DXi-PPED-TW-M8C Controller A (decoder controller)DXi-PPED-TW-M8C DXi-CELL-KIT DXi-FMW-WMS 5Y-EXT-WARRANTYDecoder 200 stations10-yearNONEBooster pump station shared flow signalController B (decoder controller)DXi-PPED-TW-M8C DXi-CELL-KIT DXi-FMW-WMS 5Y-EXT-WARRANTYDecoder 200 stations10-yearNONEBooster pump station shared flow signalController C (decoder controller)DXi-PPED-TW-M8C DXi-CELL-KIT DXi-FMW-WMS 5Y-EXT-WARRANTYDecoder 200 stations10-yearRAIN BIRD 300BPES with TORO TW-D-1 DecoderBadger Dynasonics RS-900W MODEL D8-C-020NAAP9SS-BMXX with Toro TW-DAC-FLOW DecoderController D (conventional controller) DXi-PWM-48-M8C DXi-CELL-KIT DXi-FMW-WMS 5Y-EXT-WARRANTY24-volt 48 stations10-yearRAIN BIRD 300BPES with TORO TW-D-1 DecoderBadger Dynasonics RS-900W MODEL D8-C-020NAAP9SS-BMXX with Toro TW-DAC-FLOW DecoderController E (decoder controller)DXi-PPED-TW-M8C DXi-CELL-KIT DXi-FMW-WMS 5Y-EXT-WARRANTYDecoder 200 stations10-yearRAIN BIRD 300BPES with TORO TW-D-1 DecoderBadger Dynasonics RS-900W MODEL D8-C-020NAAP9SS-BMXX with Toro TW-DAC-FLOW DecoderController F (decoder controller)DXi-PPED-TW-M8C DXi-CELL-KIT DXi-FMW-WMS 5Y-EXT-WARRANTYDecoder 200 stations10-yearRAIN BIRD 300BPES with TORO TW-D-1 DecoderBadger Dynasonics RS-900W MODEL D8-C-020NAAP9SS-BMXX with Toro TW-DAC-FLOW DecoderRain CanTexas Instruments TR-525IUse pulse decoder. Connect to Controller F. Signal to be relayed to Sentinel software1-yearTablet PCMicrosoft Surface Pro 10 for Business Intel Core Ultra 7 165U-5g-32GB RAM 256GB SSD MS Complete 2yr exchange warranty, Thunderbolt 4 Dock, Surface USB-C Travel Hub, Type Cover w/PenOr approved equal with Toro WMS software installed via free licensed installation from the Toro Company. Consult authorized Toro Sentinel Servicing Agent.One-year cell service, two year equipment warrantyTablet PC Bump Case URBAN ARMOR GEAR UAG Designed for Microsoft Surface Pro 10 Case with Built-in Kickstand Hand & Shoulder Strap Pen Holder Compatible with Type Cover Keyboard Or approved equal1-year THE SELECTED IRRIGATION INSTALLER SHALL INSTALL AND CONNECT ALL IRRIGATION CONTROLLERS, TEST, TROUBLESHOOT, PLACE INTO SERVICE AND ENTER BASIC IRRIGATION STATION DATA AND IRRIGATION SCHEDULES THAT ENABLE COORDINATED IRRIGATION OPERATIONS WITHIN 10-HOUR WATER WINDOWS AND WITHOUT HYDRAULIC OVERLOADING INCLUDING AVOIDANCE OF EXCEEDING FIVE FEET PER SECOND WATER VELOCITY THROUGH PIPES AND AVOIDING EXCEEDING WATER SUPPLY CAPABILITY OF THE MUNICIPAL IRRIGATION BOOSTER PUMP STATION. THE SELECTED IRRIGATION INSTALLER SHALL CONTACT CHRIS NAGY OF THE TORO COMPANY CHRIS.NAGY@TORO.COM, 248-342-4570 TO ARRANGE FOR THE CORRECT CONFIGURATION OF THE NEW TABLET PC AND SOFTWARE REGISTRATION IN THE OWNER'S NAME INCLUDING ADMINISTRATOR AND LOWER USER CREDENTIALS, SATELLITE CONTROLLER COMMUNICATIONS AND COMMUNICATION WITH THE PUMP STATION MONITOR. CHRIS.NAGY@TORO.COM, 248-342-4570 TO ARRANGE FOR THE CORRECT CONFIGURATION OF THE NEW TABLET PC AND SOFTWARE REGISTRATION IN THE OWNER'S NAME INCLUDING ADMINISTRATOR AND LOWER USER CREDENTIALS, SATELLITE CONTROLLER COMMUNICATIONS AND COMMUNICATION WITH THE PUMP STATION MONITOR. , 248-342-4570 TO ARRANGE FOR THE CORRECT CONFIGURATION OF THE NEW TABLET PC AND SOFTWARE REGISTRATION IN THE OWNER'S NAME INCLUDING ADMINISTRATOR AND LOWER USER CREDENTIALS, SATELLITE CONTROLLER COMMUNICATIONS AND COMMUNICATION WITH THE PUMP STATION MONITOR. JIM LAICHE OF THE TORO COMPANY JIM.LAICHE@TORO.COM , 804-334-2225 SHALL ARRANGE FOR A FACTORY AUTHORIZED TORO SENTINEL SERVICING AGENT TO DELIVER TO DESIGNATED OWNER PERSONNEL, EXTENSIVE IRRIGATION COMPUTER CENTRAL CONTROL HARDWARE AND SOFTWARE TRAINING. JIM.LAICHE@TORO.COM , 804-334-2225 SHALL ARRANGE FOR A FACTORY AUTHORIZED TORO SENTINEL SERVICING AGENT TO DELIVER TO DESIGNATED OWNER PERSONNEL, EXTENSIVE IRRIGATION COMPUTER CENTRAL CONTROL HARDWARE AND SOFTWARE TRAINING. , 804-334-2225 SHALL ARRANGE FOR A FACTORY AUTHORIZED TORO SENTINEL SERVICING AGENT TO DELIVER TO DESIGNATED OWNER PERSONNEL, EXTENSIVE IRRIGATION COMPUTER CENTRAL CONTROL HARDWARE AND SOFTWARE TRAINING. THE FACTORY AUTHORIZED TORO SENTINEL SERVICING AGENT SHALL PROVIDE FOR NOT LESS THAN FOUR BUSINESS DAYS FOR A COMPLETE REVIEW, ADJUSTMENT, TESTING, DOCUMENTATION AND PLACEMENT INTO SERVICE OF THE NEW TORO SENTINEL DXI WITH WMS REMOTE CENTRAL CONTROL SOFTWARE INCLUDING: * INSTALL ANY REQUIRED UPDATES TO THE LAPTOP FIRMWARE, DRIVERS AND OPERATING SYSTEM INSTALL ANY REQUIRED UPDATES TO THE LAPTOP FIRMWARE, DRIVERS AND OPERATING SYSTEM * CONFIRM HARDWARE AND SOFTWARE WARRANTY AND SUPPORT REGISTRATION WITH TORO NATIONAL SERVICE NETWORK (NSN) CONFIRM HARDWARE AND SOFTWARE WARRANTY AND SUPPORT REGISTRATION WITH TORO NATIONAL SERVICE NETWORK (NSN) * ENTER ADMINISTRATOR AND SUBORDINATE USER PRIVILEGES DESIGNATED BY THE OWNER ENTER ADMINISTRATOR AND SUBORDINATE USER PRIVILEGES DESIGNATED BY THE OWNER OWNER * CONFIRM ADEQUATE COMMUNICATION WITH REQUIRED INTERNET RESOURCES AND FIELD DEVICES CONFIRM ADEQUATE COMMUNICATION WITH REQUIRED INTERNET RESOURCES AND FIELD DEVICES * INSTALL, PROGRAM, TEST, DOCUMENT AND PLACE INTO SERVICE: INSTALL, PROGRAM, TEST, DOCUMENT AND PLACE INTO SERVICE: * TORO AUTHORIZED INTERNET-BASED WEATHER SERVICE TORO AUTHORIZED INTERNET-BASED WEATHER SERVICE * ALARM CONDITION NOTIFICATIONS TO DESIGNATED OWNER REPRESENTATIVE ALARM CONDITION NOTIFICATIONS TO DESIGNATED OWNER REPRESENTATIVE * CELLULAR PHONE/FIELD TABLET-BASED REMOTE-CONTROL APPLICATION CELLULAR PHONE/FIELD TABLET-BASED REMOTE-CONTROL APPLICATION * OTHER FEATURES AND/OR SERVICES THAT WILL MAXIMIZE THE OWNER'S EFFICIENT USE OF THE TORO SENTINEL REMOTE CONTROL HARDWARE AND SOFTWARE. OTHER FEATURES AND/OR SERVICES THAT WILL MAXIMIZE THE OWNER'S EFFICIENT USE OF THE TORO SENTINEL REMOTE CONTROL HARDWARE AND SOFTWARE. TORO SENTINEL REMOTE CONTROL HARDWARE AND SOFTWARE. SOFTWARE. * PROGRAM, TEST, DOCUMENT AND PLACE INTO SERVICE: PROGRAM, TEST, DOCUMENT AND PLACE INTO SERVICE: * AVAILABLE INTEGRATION(S) WITH THE WATERTRONICS WATERVISION PUMP MONITORING SOFTWARE, COORDINATE WITH WATERTRONICS AVAILABLE INTEGRATION(S) WITH THE WATERTRONICS WATERVISION PUMP MONITORING SOFTWARE, COORDINATE WITH WATERTRONICS SOFTWARE, COORDINATE WITH WATERTRONICS * TIPPING RAIN BUCKET TIPPING RAIN BUCKET * SHARED BOOSTER PUMP FLOW SIGNAL SHARED BOOSTER PUMP FLOW SIGNAL * FLOW SENSORS ADDED TO SUBSYSTEMS SYSTEMS C (FSC, D (FSD), E (FDE), F (FSF) FLOW SENSORS ADDED TO SUBSYSTEMS SYSTEMS C (FSC, D (FSD), E (FDE), F (FSF) * FLOW ZONES ASSOCIATED WITH FLOW SENSORS C, D, E, F. SUBSYSTEMS A AND B SHALL HAVE FLOW DATA ASSIGNED FROM THE BOOSTER PUMP STATION SHARED FLOW SIGNAL. FLOW ZONES ASSOCIATED WITH FLOW SENSORS C, D, E, F. SUBSYSTEMS A AND B SHALL HAVE FLOW DATA ASSIGNED FROM THE BOOSTER PUMP STATION SHARED FLOW SIGNAL. FLOW SIGNAL. * FLOW TESTING AND DATA ENTRY FOR ALL IRRIGATION STATIONS. FLOW TESTING AND DATA ENTRY FOR ALL IRRIGATION STATIONS. * FLOW WATCH FOR ALL IRRIGATION STATIONS - HIGH AND LOW FLOW ALARM NOTIFICATIONS FLOW WATCH FOR ALL IRRIGATION STATIONS - HIGH AND LOW FLOW ALARM NOTIFICATIONS * FLOW OPTOMIZATION OF IRRIGATION SCHEDULES FLOW OPTOMIZATION OF IRRIGATION SCHEDULES * SELECTABLE WEATHER-BASED IRRIGATION SCHEDULES SELECTABLE WEATHER-BASED IRRIGATION SCHEDULES * SELECTABLE FIXED IRRIGATION SCHEDULES SELECTABLE FIXED IRRIGATION SCHEDULES * FURNISH AND DOCUMENT NOT LESS THAN FOUR HOURS OF TRAINING TO THE OWNER OF TORO SENTINEL REMOTE CONTROL SOFTWARE, BASIC THROUGH ADVANCED, TRAINING IN THE INSTALLATION AND USE OF THE CELLULAR PHONE/FIELD TABLET APPLICATION, ADMINISTRATOR TRAINING IN THE ASSIGNMENT AND REVOCATION OF SUBORDINATE USER PRIVILEGES. FURNISH AND DOCUMENT NOT LESS THAN FOUR HOURS OF TRAINING TO THE OWNER OF TORO SENTINEL REMOTE CONTROL SOFTWARE, BASIC THROUGH ADVANCED, TRAINING IN THE INSTALLATION AND USE OF THE CELLULAR PHONE/FIELD TABLET APPLICATION, ADMINISTRATOR TRAINING IN THE ASSIGNMENT AND REVOCATION OF SUBORDINATE USER PRIVILEGES. THE IRRIGATION COMPUTER CENTRAL CONTROL HARDWARE AND SOFTWARE TRAINING SHALL BE CLEARLY AND UNDERSTANDABLY VIDEO AND AUDIO RECORDED. THE RECORDING SHALL BE EDITED TO INCLUDE SEARCHABLE CHAPTERS/TOPICS AND SHALL BE DELIVERED TO THE OWNER FOR FUTURE REFERENCE AS A CONDITION OF PROJECT CLOSEOUT.

CP1

CP3

CP2

CP4

DN

LI

S C U M

D R

IV

E (R

/W W

ID

TH

V A R

IE

S

MICHIGAN AVENUE MICHIGAN AVENUE

SW

SW

SW

NEW MEXICO PLACE

OHIO

AV

EN

UE

PE

NN

SY

LV

AN

IA

AV

EN

UE

WEST THIRD STREET

(R/W WIDTH VARIES)

H

AW

AI

I P

LA

C E

G

ET

TY

S B U R G

A V

EN

U E

(R /W

W

ID

TH

V

A R

IE

S

NEW MEXICO AVE

NE

W

M

EX

IC

O

P

LA

C E

SW

CONTROLLER B

WIRE PATH

4"

4"

4"

4"

10"

3"

3"

3"

3"

3"

3"

10"

3"

10"

4"

3"

3"

3"

3"

4"

4"

4"

4"

4"

4"

4"

3"

3"

3"

3"

3"

3"

8"

8"

8"

8"

10"

3"3"

1.25"

1.25"

2"

2"

3"

1.25"

1.25"

2"

3"

8"

4"

SW

DAKOTA AVENUE

TEXAS AVENUE

IN

D

IA

N A A

V

EN

U E

LI

S C U M

D R

IV

E (R

/W W

ID

TH

V A R

IE

S

KA

NS

AS

A

VE

NU

E

MCMAHON AVENUE

CO

LO

RA

DO

A

VE

NU

E

WEST THIRD STREET

(R/W WIDTH VARIES)

C O

N S

TR

U C

TI

O

N C

EN

TE

R

LI

N E

M O

T-

LI

S C

U M

D R

IV

E (P

ID

MCMAHON AVENUE

TEXAS AVENUE

BROWN AVENUE

SW

WISCONSIN AVENUE

WISCONSIN AVENUE

4"

3"

8"

8"

8"

3"

SW

SW

SW

SW

SW

SW

SW

WS

SW

CONTROLLER A

SW

2"

SW

WIRE PATH

Q

Q

Q

Q

Q

Q

Q

Q

Q

Q

Q

Q

Q

Q

Q

Q

F Q

Q

Q

Q

F

F

F

Q

Q

Q

Q

Q

Q

Q

Q

Q

Q

Q

Q

Q

Q

Q

Q

Q

Q

Q

Q

Q

Q

Q

Q

Q

Q

Q

Q

A

Q

Q

Q

Q

Q

Q

Q

Q

PUMP

STATION

VAULT

Ohio

Q

POINT OF CONNECTION

TO EXISTING SYSTEM

P…

This is the start of the file's text. The full file is on GovTribe.