REF REF
REF
ASSEMBLY TYPE (SEE ASSEMBLIES SHEET)
ASSEMBLY MODIFIER, PER TYPE
ROOM NAME AND NUMBER
WINDOW TYPE (SEE A600s)
KEYNOTE
DRAWING NUMBER
SHEET WHERE DRAWN
DOOR NUMBER (SEE SHEET A601)
DIMENSION TO FACE OF FRAMING
DIMENSION TO GRID LINE
A101
SIM
X
XX
NAME
X
X
PLAN LEGEND
DIRECTION OF VIEW, IF APPLICABLE
DIMENSION TO CENTER LINE
CL
FIRE EXTINGUISHER CABINET AND
EXTINGUISHER - SEE SPECIFICATIONSFEC
A201
A2012
A201
A201
A301
A301
A301
______________2
A301
I.T./PACS
ROOM
HUDDLE
ROOM
WELLNESS
HALL
PRIVATE
OFFICE
HUDDLE
ROOM
PRIVATE
OFFICE
HUDDLE
ROOM
FIRE READY
ROOM
HUDDLE
ROOM
FOCUS
ROOM
FIRE SUITE
MEP
BREAK
AREA
SMALL
CONFERENCE
ROOM
FIELD
OFFICE/S.S./DISTRICT
STAFF
JAN.
STAFF
VESTIBULE
STAFF
VESTIBULE
MAIL ROOM
A702
A701
A702
A C
110-1111-1
125-1
A C
122-1
106-1
107-1121-1
123-1
124-1
A C
A C
VE
VE
VE
VE
VA
VD VE VE VE VE
VE
VE
VE
VE
VE
VE
VE
VE
VE VE VE
VA VA
VE
ENTRY HALL
MAIN
CONFERENCE
ROOM FIELD
OFFICE
LOBBY/ENTRY
RECEPTION
OFFICE
SUPPLY/PLOTTER
ROOM
A C
A C
A C
A C
126-2AC126-1AC
VAVAVB
H128-2AC
VE VE VE VE
VE
VE
VE
SMALL
CONFERENCE
ROOM
W.R.R.
VE
VA
VESTIBULE
A C
105-1
VE VE VE
A701
A701
A301
ALB
C
D D
C
C
C
D
D
D
C
C
D
B
B
B
A
A
B B
A
A
B
E
A
A
A
B
A
B
A
A
A 1 B
A
D
A
D
D
A.1
B
A
E
B
A
A
E
A A
A
B 1,3
B
A
A
B 1,3
A
B
B B.1
AA
A
B.1
B
E
R.R.
R.R.
B
A.1
42' - 6"
42' - 8"
40' - 8" 42' - 4" 43' - 0" 47' - 8"
90' - 4" 40' - 8"
6'
5'
7'
C L C L
C L C L
C L 5'
4"
8'
7'
8'
CLCLCLCL
7' - 3" 8' - 0" 12' - 0" 8' - 0"
CLCLCLCLCL
8' - 0" 8' - 0" 8' - 0" 8' - 0" 4' - 5"
CLCLCLCL5' - 6" 8' - 0" 8' - 0" 8' - 0"
CLCLCLCLCLCL 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 3' - 3"
C L C L
C L C L
C L C L
C L C L
7'
8'
8'
8'
8'
8'
8'
2"
9' - 10"
CL
EA
R
6'
5' - 6" 11' - 7" 5' - 8" 5' - 11 1/2" 12' - 0"
2'
0"
9'
1"
12' - 5 27/32"
6' - 0"
6' - 0"
11' - 10" 21' - 0"
103-1
3' - 0"
B
M.R.R.
B
B
127-1AC
1 5 6 8 9 11 13 14 15 16 17 18 19
A
B
C
2 3 4 7 10
D D
IT STRG.
117A
A C
A.1
A.1A.1
A
A
AFEC
FEC
FEC
A111
9' - 4" 3' - 4" 5' - 4" 4' - 0" 5' - 4" 3' - 4"3' - 4"4' - 0"3' - 4"4' - 0" 11' - 4" 4' - 8" 6' - 8" 3' - 4" 12' - 0" 4' - 0"
A111
A111
BELOW AT
COLUMN BASE
AT COLUMN
CAP
42' - 8" 2' - 4" 11' - 9" 3' - 8" 17' - 9" 9' - 10 1/2" 7' - 8" 13' - 5" 4' - 4" 10' - 9" 7' - 0" 22' - 6" 18' - 2"
0"
13' - 6" 13' - 6" 13' - 8" 13' - 9" 14' - 2" 14' - 5" 88' - 10 1/2"
B.1
B 1,3
B
B
B
B
E
E
A
4' - 0" 8' - 0" 4' - 0"
2' - 8"
2' - 8"4' - 0" 8' - 0" 4' - 0" D
2'
4'
VFVFVFVF
VF
A
FEC
104-1AC
A
B
A
A
A.1
FIELD
OFFICE/S.S./DISTRICT
STAFF
A
A
8' - 1"
3'
A. SEE CIVIL, STRUCTURAL, MECHANICAL, AND ELECTRICAL
DRAWINGS FOR ADDITIONAL REQUIREMENTS AND
COORDINATION.
B. SEE FIRE DRAWINGS FOR ADDITIONAL WORK TO OCCUR AND
ADDITIONAL REQUIREMENTS.
C. SEE A001 AND A101 FOR WALL TYPE INFORMATION AND
LOCATIONS.
D. SEE CODE PLAN FOR INFORMATION ON SQUARE FOOTAGE OF
BUILDING AND OTHER RELATED ITEMS.
E. SEE CODE PLAN FOR ENVELOPE ENERGY REQUIREMENTS.
F. SEE SPECIFICATIONS FOR ALL BUILDING COMPONENTS.
G. SEE EXTERIOR ELEVATIONS ON A201 FOR LOCATIONS OF CMU
VENEER AT BASE OF EXTERIOR WALLS.
H. COORDINATE EXTERIOR WALL DIMENSIONS AND FACE OF STEM
WALL LOCATIONS WITH STRUCTURAL DRAWINGS.
I. DIMENSIONS OF WINDOWS LOCATED WITHIN STUCCO ARE TO
CENTERLINE OF WINDOW. DIMENSIONS TO WINDOWS AND
FRAMES LOCATED WITHIN CMU VEENER ARE TO OUTSIDE OF
ROUGH OPENING.
J. SEE FINISH PLAN ON A501 FOR COORDINATION OF FINISHES
AND OTHER ITEMS MOUNTED ON INTERIOR WALLS.
K. SEE A501 FOR ROLLER SHADE LOCATIONS.
L. PROVIDE METAL STUD BLOCKING IN WALL AS NEEDED FOR
ALL MOUNTED EQUIPMENT, MILLWORK, AND HARDWARE,
COORDINATE WITH WALL TYPES.
GENERAL NOTES
P
LO
T
D A T E
P
LO
T T E D
B Y
C H K 'D
B Y
D E S
IG
N
O F F
IC
E
D E S
IG
N E D
B Y
P R O J E C T
N O
D R A W N
B Y
A P P R O V E D
B Y
U N
IT
E D
S T A T E S
D E P A R T M E N T
O F
T H E
IN
T E R
IO
R
B U R E A U
O F
L A N D
M A N A G E M E N T
D A T E
D E S C R
IP
T
IO
N
M A R K
A P P R O V E D
D A T E
SHEET OF
:3 :3
P M
C U s e rs a lf o n s o ra m ir e z D o c u m e n ts R e vi tL o c a lT e m p N W B L M D O a rc h a lf o n s o ra m ir e z .r vt
F L O O R
P L A N
A101
N W B L M D O
S H O S H O N E
F
IE
L D
O F F
IC
E
R E P L A C E M E N T
J R C
R H
C U S H
IN
G
T E R R E L L
J R C
B L M
.1 .2
T W
IN
F A L L S
D
IS
T R
IC
T
ID
A H O
59 124
# SHEET NOTES
1 OPERABLE PARTITION DOOR. SEE SPECIFICATIONS.
STRUCTURAL SUPPORTS NECESSARY, SEE STRUCTURAL
DRAWINGS FOR STRUCTURAL STEEL ASSOCIATED WITH DOOR.
2 MECHANICAL EQUIPMENT, SEE MECHANICAL DRAWINGS.
3 FIRE SPRINKLER RISER, SEE FIRE DRAWINGS.
4 PLUMBING ACCESS AREA. SEE PLUMBING DRAWINGS FOR
PIPING LOCATIONS.
5 PRINTER BY GOVERNMENT, NOT IN CONTRACT.
A101
1 FLOOR PLAN
NORTH REF
SCALE IN FEET
A.1
A
A.1
PARTITION MANUFACTURER SELECTED
COORDINATE SIZE WITH OPERABLE
PA
RT
IT
IO
N M
AN
U
FA
CT
UR
ER
S
EL
EC
TE
D
CO
O
RD
IN
AT
E
SI
ZE
W
IT
H O
PE
RA
BL
E
STRUCTURAL STEEL COLUMN ASSOCIATED
WITH OPERABLE PARTITION, SEE
STRUCTURAL DRAWINGS.
OPERABLE PARTITION - SEE
SPECIFICATION 102239 FOR FURTHER
INFORMATION
5"
5"
2' - 9"
2'
SEALANT
TYP.
1/2"1
A311
S L O P E
SLOPE SLOPE
S L O P E
CL
CL
4"X8"X16" CMU BLOCK
FULLY GROUTED, RUNNING
BOND, BLOCK COLOR TO
MATCH BUILDING BLOCK
COLOR, SEE STRUCTURAL
DRAWING FOR FURTHER
DETAILS
STRUCTURAL STEEL
COLUMN
CL
CL
P
LO
T
D A T E
P
LO
T T E D
B Y
C H K 'D
B Y
D E S
IG
N
O F F
IC
E
D E S
IG
N E D
B Y
P R O J E C T
N O
D R A W N
B Y
A P P R O V E D
B Y
U N
IT
E D
S T A T E S
D E P A R T M E N T
O F
T H E
IN
T E R
IO
R
B U R E A U
O F
L A N D
M A N A G E M E N T
D A T E
D E S C R
IP
T
IO
N
M A R K
A P P R O V E D
D A T E
SHEET OF
:3 :3
P M
C U s e rs a lf o n s o ra m ir e z D o c u m e n ts R e vi tL o c a lT e m p N W B L M D O a rc h a lf o n s o ra m ir e z .r vt
P L A N
D E T A
IL
S
A111
N W B L M D O
S H O S H O N E
F
IE
L D
O F F
IC
E
R E P L A C E M E N T
J R C
R H
C U S H
IN
G
T E R R E L L
J R C
B L M
.1 .2
T W
IN
F A L L S
D
IS
T R
IC
T
ID
A H O
60 124
A111
3 FOLDING PARTITION POCKET
SCALE IN FEET
A111
2 TYPICAL COLUMN W RAP AT CONCRETE CAP
SCALE IN FEET
A111
1 TYPICAL COLUMN W RAP AT BASE
A201
A2012
A201
A201
A301
A301
A301
______________2
A301
B E L O W
A B O V E
VCVCVCVCVCVCVCVCVCVCVCVC
A301
8'
2' - 0"
2'
2' - 0"
2' - 0"
2'
2' - 0"
2'
2' - 0"
2'
2' - 0"
2'
3 3 3 3 3 3 333333
2' - 0"
2' - 0"
1 5 6 8 9 11 13 14 15 16 17 18 19
AA
BB
C
2 3 4 7 10
D D
5 5
1'
3'
4"
1'
CLCLCLCLCLCLCLCLCLCLCLCL
8' - 0" 8' - 0" 11' - 0" 8' - 0" 25' - 6" 8' - 0" 8' - 0" 8' - 0" 51' - 0" 8' - 0" 8' - 0" 8' - 0"
A122
A122
A122
A122
A122
______________5
A122
A122
A122
A122
A122
A122
A122
A122
A122
45' - 6"
3'
CL
E.Q. E.Q.
6' - 0"
TYP. OF 4
6 6
A122
A122
1. THE FOLLOWING REFERENCES HAVE BEEN USED AS A BASIS
FOR DESIGN OF THE ROOFING RELATED WORK OF THE PROJECT
AND SHALL BE USED BY THE CONTRACTOR TO DETERMINE
REQUIREMENTS FOR FABRICATION AND/OR INSTALLATION WHEN
NOT SPECIFICALLY INDICATED IN THE CONTRACT DOCUMENTS.
A.NATIONAL ROOFING CONTRACTORS ASSOCIATION (NRCA)
"ROOFING AND WATER PROOFING MANUAL, FIFTH EDITION".
B. SHEET METAL AND AIR CONDITIONING NATIONAL
CONTRACTORS ASSOCIATION (SMACNA) - "ARCHITECTURAL
SHEET METAL MANUAL, FIFTH EDITION".
C. INTERNATIONAL BUILDING CODE: MOST CURRENT
ADOPTED VERSION
D. INTERNATIONAL PLUMBING CODE: MOST CURRENT
ADOPTED VERSION
E. AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE) -
ASCE/SEI 7-10: "MINIMUM DESIGN LOADS FOR BUILDINGS
AND OTHER STRUCTURES" (REVISION OF ASCE/SEI 7-05).
F. MATERIAL MANUFACTURERS MOST RECENT PRINTED
SPECIFICATIONS AND INSTALLATION DETAILS.
2. PRIOR TO THE START OF WORK THE CONTRACTOR SHALL
PROVIDE AND INSTALL PROTECTION OVER, UNDER AND/OR
AROUND ALL SERVICE LINES, BUILDING COMPONENTS,
SIDEWALKS, PAVEMENT AND LANDSCAPING WHICH COULD BE
DAMAGED OR SOILED WHILE PERFORMING WORK OF THE
CONTRACT.
3. DETAILS IN THE PROJECT DRAWINGS ARE SHOWN AT
SPECIFIC LOCATIONS AND ARE INTENDED TO SHOW GENERAL
REQUIREMENTS THROUGHOUT:
A. DETAILS NOTED ARE "TYPICAL" AND IMPLY ALL SIMILAR
CONDITIONS TREATED SIMILARLY. MODIFICATIONS TO BE
MADE BY THE CONTRACTOR TO ACCOMMODATE MINOR
VARIATIONS WITHOUT ADDITIONAL COST TO THE GOVERNMENT.
GENERAL ROOFING NOTES
MATERIALS LEGEND
STANDING SEAM METAL ROOF PANEL PER
SPECIFICATION 074113.16- ROOF ASSEMBLY
'H1' - SEE ASSEMBLY DETAILS SHEET
P
LO
T
D A T E
P
LO
T T E D
B Y
C H K 'D
B Y
D E S
IG
N
O F F
IC
E
D E S
IG
N E D
B Y
P R O J E C T
N O
D R A W N
B Y
A P P R O V E D
B Y
U N
IT
E D
S T A T E S
D E P A R T M E N T
O F
T H E
IN
T E R
IO
R
B U R E A U
O F
L A N D
M A N A G E M E N T
D A T E
D E S C R
IP
T
IO
N
M A R K
A P P R O V E D
D A T E
SHEET OF
:3 :4
P M
C U s e rs a lf o n s o ra m ir e z D o c u m e n ts R e vi tL o c a lT e m p N W B L M D O a rc h a lf o n s o ra m ir e z .r vt
R O O F
P L A N
A121
N W B L M D O
S H O S H O N E
F
IE
L D
O F F
IC
E
R E P L A C E M E N T
J R C
R H
C U S H
IN
G
T E R R E L L
J R C
B L M
.1 .2
T W
IN
F A L L S
D
IS
T R
IC
T
ID
A H O
61 124
NORTH REF
SCALE IN FEET
A121
1 ROOF PLAN
# SHEET NOTES
1 GUTTER AND DOWNSPOUTS, SEE EXTERIOR ELEVATIONS FOR
DOWNSPOUT LOCATIONS.
2 LINE OF FACE OF EXTERIOR STUD BELOW.
3 WINDOW AT FACADE BELOW. SEE A201 AND A601 FOR
FURTHER INFORMATION.
4 MECHANICAL VENT PENETRATIONS, SEE MECHANICAL
DRAWINGS. REFER TO 1/A124 AND 2/A124 FOR
ADDITIONAL INFORMATION.
5 TUBULAR DAYLIGHTING DEVICE UNIT SKYLIGHT, SEE
SPECIFICATIONS AND ROOF DETAILS SHEET FOR FURTHER
INFORMATION. SEE CEILING PLAN FOR DAYLIGHT TUBE
DIFFUSER LOCATIONS. REFER TO 4/A124 AND 5/A124 FOR
ADDITIONAL INFORMATION.
6 ONE ROW OF SNOW FENCE REQUIRED WITH ASSOCIATED
SEAM CLAMPS. START CLAMPS 1'-0" FROM THE EAVE.
SPACE CLAMPS 16" O.C. (AT SEAMS). INSTALL SNOW CLIP
ONTO ASSOCIATED BAR BETWEEN EVERY PAIR OF SEAMS.
SEE SPECIFICATIONS FOR FURTHER INFORMATION.
7 PLUMBING VENT
TOP OF W ALL
113'-0"
C
SEALANT
FIRE TREATED WOOD NAILERS
PREFINISHED BREAK METAL FASCIA FLASHING,
BREAK INTO TWO SEPARATE PIECES
2x12 TREATED WOOD BLOCKING
SEALANT
CONTINUOUS CLEAT
PREFINISHED METAL COPING
STRUCTURAL FRAMING, SEE
STRUCTURAL DRAWINGS
SECURE @ 12" O.C. USING HEX HEAD,
GASKETED #12 GALVANIZED STEEL
THREADED FASTENERS
LAP TEMPORARY ROOF AND VAPOR
RETARDER DOWN OVER BLOCKING
2x8 TREATED WOOD BLOCKING
METAL SOFFIT PANEL
FOAM IN PLACE INSULATION -
COVER FIRST DECK FLUTE
FOR DIMENSIONS
SEE ROOF PLAN
STRUCTURAL FRAMING, SEE
STRUCTURAL DRAWINGS
DRIP EDGE
EDGE ANGLE, SEE STRUCTURAL DRAWINGS
WEATHER BARRIER, SEAL TO DECK
VAPOR RETARDER, SEAL TO DECK
SEALANT
FIRE TREATED WOOD NAILERS
PREFINISHED BREAK METAL
FASCIA FLASHING, BREAK INTO
TWO SEPARATE PIECES
2x12 TREATED WOOD BLOCKING
SEALANT
CONTINUOUS CLEAT
PREFINISHED METAL COPING
STRUCTURAL STEEL HSS -
SEE STRUCTURAL DRAWINGS
SECURE @ 12" O.C. USING HEX
HEAD,
GASKETED #12 GALVANIZED STEEL
THREADED FASTENERS
LAP TEMPORARY ROOF AND VAPOR
RETARDER DOWN OVER BLOCKING
2x8 TREATED WOOD BLOCKING
METAL SOFFIT PANEL
FOAM IN PLACE INSULATION -
COVER FIRST DECK FLUTE
STRUCTURAL FRAMING, SEE
STRUCTURAL DRAWINGS
FLOATING RAKE SUPPORT WITH
NECESSARY FASTENERS
H1
C
EDGE ANGLE, SEE
STRUCTURAL DRAWINGS
WEATHER BARRIER, SEAL TO DECK
VAPOR RETARDER, SEAL TO DECK
B
SEALANT
FIRE TREATED WOOD NAILERS
PREFINISHED BREAK METAL
FASCIA FLASHING, BREAK INTO
TWO SEPARATE PIECES
2x12 TREATED WOOD BLOCKING
SEALANT
CONTINUOUS CLEAT
PREFINISHED METAL COPING
2 1/2" COLD FORMED FRAMING
SECURE @ 12" O.C. USING HEX HEAD,
GASKETED #12 GALVANIZED STEEL
THREADED FASTENERS
LAP TEMPORARY ROOF AND VAPOR
RETARDER DOWN OVER BLOCKING
2x8 TREATED WOOD BLOCKING
METAL SOFFIT PANEL
FOAM IN PLACE INSULATION -
COVER FIRST DECK FLUTE
STRUCTURAL FRAMING, SEE
STRUCTURAL DRAWINGS
C
2 1/2" COLD FORMED FRAMING
FOAM IN PLACE INSULATION -
FILL CAVITY
BATT INSULATION
3" / 1'-0"
DRIP EDGE
H1
EDGE ANGLE, SEE STRUCTURAL DRAWINGS
WEATHER BARRIER, SEAL TO DECK
VAPOR RETARDER, SEAL TO DECK
SLIP TRACK TO BE FRAMED ALONG
ENTIRE LENGTH OF STRUCTURAL
FRAMING, SEE STRUCTURAL DRAWINGS.
BATT INSULATION
B
H1
EXTERIOR
INTERIOR
INTERIOR
PRE-FINISHED METAL FLASHING
FASTENER, TYP.
PRE-FINISHED METAL COUNTERFLASHING
PRE-FINISHED METAL REGLET
FLASHING
RUN METAL FLASHINGS BEHIND
INSULATION
LAP SELF ADHERING VAPOR
RETARDER UP SHEATHING
LAP BUILDING WRAP FLASHING OVER
METAL FLASHINGS
CLIP AND BEARING PLATE
FOR STANDING SEAM
METAL ROOF
C
STRUCTURAL FRAMING, SEE
STRUCTURAL DRAWINGS
2 1/2" COLD FORMED
FRAMING
BATT INSULATION
M
IN
8"
FIRE TREATED WOOD NAILERS
2x12 TREATED WOOD BLOCKING
LAP TEMPORARY ROOF AND VAPOR
RETARDER DOWN OVER BLOCKING
2x8 TREATED WOOD BLOCKING
METAL SOFFIT PANEL
STRUCTURAL FRAMING, SEE
STRUCTURAL DRAWINGS
DRIP EDGE
HOOK PANEL OVER DRIP
EDGE - REFER TO NOTE #1
STYLE D DRIP EDGE
W/CONTINUOUS CLEAT
SELF ADHERING MEMBRANE -
LAP S.A.M. ONTO FASCIA
PRE-FINISHED METAL FLASHING WITH
DRIP EDGE - COLOR TO MATCH METAL
PANEL ROOFING - WRAP BREAK METAL
SEPARATE INTO TWO PIECES TO PREVENT
OIL CANNING, NO EXPOSED FASTENERS.
WITH CONTINIOUS CLEAT.
SEE GUTTER DETAIL ON A123
FOR FURTHER INFORMATION
AND DIMENSIONS M
IN
1/
2"
EDGE ANGLE, SEE
STRUCTURAL DRAWINGS
H1
SEALANT
FIRE TREATED WOOD NAILERS
PREFINISHED BREAK METAL
FASCIA FLASHING, BREAK INTO
TWO SEPARATE PIECES
2x12 TREATED WOOD BLOCKING
SEALANT
CONTINUOUS CLEAT
PREFINISHED METAL COPING
STRUCTURAL STEEL HSS -
SEE STRUCTURAL DRAWINGS
SECURE @ 12" O.C. USING HEX
HEAD,
GASKETED #12 GALVANIZED STEEL
THREADED FASTENERS
LAP TEMPORARY ROOF AND VAPOR
RETARDER DOWN OVER BLOCKING
2x8 TREATED WOOD BLOCKING
METAL SOFFIT PANEL
FOAM IN PLACE INSULATION
STRUCTURAL FRAMING, SEE
STRUCTURAL DRAWINGS
FLOATING RAKE SUPPORT WITH
NECESSARY FASTENERS
H1
EDGE ANGLE, SEE
STRUCTURAL DRAWINGS
WEATHER BARRIER, SEAL TO DECK
VAPOR RETARDER, SEAL TO DECK
P
LO
T
D A T E
P
LO
T T E D
B Y
C H K 'D
B Y
D E S
IG
N
O F F
IC
E
D E S
IG
N E D
B Y
P R O J E C T
N O
D R A W N
B Y
A P P R O V E D
B Y
U N
IT
E D
S T A T E S
D E P A R T M E N T
O F
T H E
IN
T E R
IO
R
B U R E A U
O F
L A N D
M A N A G E M E N T
D A T E
D E S C R
IP
T
IO
N
M A R K
A P P R O V E D
D A T E
SHEET OF
:3 :4
P M
C U s e rs a lf o n s o ra m ir e z D o c u m e n ts R e vi tL o c a lT e m p N W B L M D O a rc h a lf o n s o ra m ir e z .r vt
R O O F
D E T A
IL
S
A122
N W B L M D O
S H O S H O N E
F
IE
L D
O F F
IC
E
R E P L A C E M E N T
J R C
R H
C U S H
IN
G
T E R R E L L
J R C
B L M
.1 .2
T W
IN
F A L L S
D
IS
T R
IC
T
ID
A H O
62 124
A122
3 TYPICAL LOW SIDE EAVE DETAIL AT DRIP EDGE
SCALE IN FEET
A122
6 TYPICAL RAKE DETAIL AT STUCCO
SCALE IN FEET
A122
2 TYPICAL HIGH EAVE DETAIL
SCALE IN FEET
SCALE IN FEET
A122
1 TYPICAL ROOF TO W ALL TRANSITION
SCALE IN FEET
A122
4 LOW EAVE DETAIL W ITH GUTTER
10.50
SCALE IN FEET
A122
5 TYPICAL RAKE DETAIL AT CMU VENEER
5"
5"
GUTTER - PRE FINISHED
24 GA GALV STEEL
GUTTER STRAP -
PRE FINISHED 24 GA
GALV STEEL 1" WIDE
AT 24" O.C.
RIVETS AT 1" O.C. ALL SIDES -
COLOR TO MATCH METAL
FULL BED OF NON CURING
SEALANT IN JOINT - TYP ALL AROUND
DROP TUBE
PRE FINISHED 24 GA GALV
STEEL DOWNSPOUT (4"x4")
3"
HEX HEAD STAINLESS STEEL
THREADED FASTENER HEAD -
COLOR TO MATCH METAL
STRAP AND DROP TUBE
GUTTER DIMENSIONS
GUTTER GUARD
SMACNA GUTTER PROFILE 'B'
RE: ROOF PLAN FOR GUTTER LOCATIONS.
RE: EXTERIOR ELEVATIONS FOR DOWNSPOUT LOCATIONS.
B
H1
EXTERIOR
INTERIOR
INTERIOR
FASTENER, TYP.
PRE-FINISHED METAL
COUNTERFLASHING
PRE-FINISHED METAL REGLET
FLASHING
RUN METAL FLASHINGS BEHIND
INSULATION
LAP SELF ADHERING VAPOR
RETARDER UP SHEATHING
CLIP AND BEARING PLATE
FOR STANDING SEAM
METAL ROOF
STRUCTURAL FRAMING, SEE
STRUCTURAL DRAWINGS
J-MOLD FOR GYPSUM
BOARD
JAMB BEYOND/BEHIND
FOAM IN PLACE
INSULATION - FILL CAVITY
6" COLD FORMED METAL
FRAMING, SEE STRUCTURAL
DRAWINGS
PRE-FINISHED METAL SILL
PAN FLASHING WITH END
DAMS AT SILL
JOINT SEALANT
SHIM AS REQUIRED
JOINT SEALANT/
BACKING EACH SIDE
A602
M
IN
8"
SEALANT
STRUCTURAL
FRAMING, SEE
STRUCTURAL
DRAWINGS
METAL SOFFIT PANEL
FOAM IN PLACE INSULATION -
COVER FIRST DECK FLUTE
STRUCTURAL FRAMING,
SEE STRUCTURAL
DRAWINGS
WEATHER BARRIER,
SEAL TO DECK
C
H1
TOP OF W ALL
113'-0"
D
SEALANT
2 1/2" COLD FORMED FRAMING
METAL SOFFIT PANEL
FOAM IN PLACE
INSULATION - COVER
FIRST DECK FLUTE
STRUCTURAL FRAMING, SEE
STRUCTURAL DRAWINGS
WEATHER BARRIER, SEAL TO DECK
H1
D
FIRE TREATED WOOD NAILERS
PREFINISHED BREAK METAL FASCIA
FLASHING, BREAK INTO TWO
SEPARATE PIECES
2x12 TREATED WOOD BLOCKING
SEALANT
CONTINUOUS CLEAT
PREFINISHED METAL COPING
SECURE @ 12" O.C. USING HEX HEAD,
GASKETED #12 GALVANIZED STEEL
THREADED FASTENERS
LAP TEMPORARY ROOF AND VAPOR
RETARDER DOWN OVER BLOCKING
2x8 TREATED WOOD BLOCKING
DRIP EDGE
EDGE ANGLE, SEE
STRUCTURAL DRAWINGS
FOR DIMENSIONS
SEE ROOF PLAN
TOP OF W ALL
113'-0"
SEALANT
STRUCTURAL FRAMING,
SEE STRUCTURAL
METAL SOFFIT PANEL
FOAM IN PLACE
INSULATION - COVER
FIRST DECK FLUTE
WEATHER BARRIER,
SEAL TO DECK
P
LO
T
D A T E
P
LO
T T E D
B Y
C H K 'D
B Y
D E S
IG
N
O F F
IC
E
D E S
IG
N E D
B Y
P R O J E C T
N O
D R A W N
B Y
A P P R O V E D
B Y
U N
IT
E D
S T A T E S
D E P A R T M E N T
O F
T H E
IN
T E R
IO
R
B U R E A U
O F
L A N D
M A N A G E M E N T
D A T E
D E S C R
IP
T
IO
N
M A R K
A P P R O V E D
D A T E
SHEET OF
:3 :5
P M
C U s e rs a lf o n s o ra m ir e z D o c u m e n ts R e vi tL o c a lT e m p N W B L M D O a rc h a lf o n s o ra m ir e z .r vt
R O O F
D E T A
IL
S
A123
N W B L M D O
S H O S H O N E
F
IE
L D
O F F
IC
E
R E P L A C E M E N T
J R C
R H
C U S H
IN
G
T E R R E L L
J R C
B L M
.1 .2
T W
IN
F A L L S
D
IS
T R
IC
T
ID
A H O
63 124
A123
4 GUTTER DIMENSIONS / STRAP AND DROP TUBE
A123
1 ROOF TO W ALL TO W INDOW TRANSITION
SCALE IN FEET
SCALE IN FEET
A123
2 TYPICAL W ALL TO ROOF TRANSITION AT TYPE C W ALL
SCALE IN FEET
A123
3 TYPICAL W ALL TO ROOF TRANSITION AT TYPE D W ALL AND EAVE DETAIL
SCALE IN FEET
A123
5 TYPICAL W ALL TO ROOF TRANSITION AT TYPE D W ALL
DIFFUSER
FRAME
CEILING TILE
SQUARE/ROUND
TRANSITION V-
CLIP
T-BAR
SQUARE/ROUND
TRANSITION
A
A
METAL DECK
EXTENSION TUBE - COORDINATE
ROUTING TO CEILING BELOW WITH
MECHANICAL, PLUMBING,
STRUCTURAL AND FIRE SYSTEM
NOTE:
-ALL TUBE JOINTS AND SEAMS TAPED WITH 2" FOIL TAPE
-MIN. ROOF SLOPE IS 2.4 DEGREES
-6" MIN. CLEARANCE SHOULD BE MAINTAINED FROM ALL
COMPONENTSSECTION VIEW
STRUCTURAL FRAMING, SEE
STRUCTURAL DRAWINGS
METAL FLASHING BY TUBULAR DAYLIGHTING
DEVICE MANUFACTURER. SEE SPECIFICATION
086200 AND DETAIL SEE 5/A124
PRE-MOLDED PIPE FLASHING
W/ALUMINUM BASE SET IN CONT.
BEAD OF URETHANE SEALANT
GASKETED FASTENER - INSTALL
PER MANF. RECOMMENDATIONS
AND INSTRUCTIONS
CONTINUOUS BEAD
URETHANE SEALANT
STAINLESS STEEL
CLAMPING RING
UNDER NO CIRCUMSTANCES CAN THE
PIPE PENETRATE OR COME WITHIN 4"
OF THE STANDING SEAM METAL PANEL
ROOF PANEL SEAM
NOTES: APPLY LAP SEALANT
BETWEEN PENETRATION AND
PRE-MOLDED PIPE FLASHING
PRIOR TO INSTALLATION OF
CLAMPING RING.
PIPE SHOULD EXTEND 1'-0"
MINIMUM ABOVE ROOF SURFACE
SEE SHEETS A121, A122, P401
AND PLUMBING DRAWINGS FOR
PENETRATION LOCATIONS
H1
NOTE: USE METAL JACK
SLEEVES AT ALL 'HOT' PIPE
PENETRATION LOCATIONS
H1
M
IN
CURB PAN
S-CLIP
SET S-CLIP IN 3/4" BUTYL TAPE
EXHAUST/INTAKE VENT CURB -
REMOVE /REINSTALL AS REQUIRED
TO INSTALL FLASHING (TYPICAL)
PREMANUFACTURED CURB
VENT/DUCT TYPICAL
#12 HEX HEAD THREADED FASTENER W/
EPDM WASHER (MIN. 3 PER SIDE)
BUILDING WRAP - FULLY FLASH CURB
- SEE SPECIFICATION 072500
H1
FIRE TREATED WOOD NAILERS
2x6 TREATED WOOD
BLOCKING
STRUCTURAL FRAMING, SEE
STRUCTURAL DRAWINGS
EDGE ANGLE, SEE
STRUCTURAL DRAWINGS
EXHAUST/INTAKE VENT CURB
PREMANUFACTURED CURB
VENT/DUCT TYPICAL
FRONT FACE CURB FLASHING -
REFER TO DETAIL 6/A105
#12 HEX HEAD THREADED FASTENER
W/ EPDM WASHER (MIN. 3 PER SIDE)
TURN PANEL LEG 1" MIN. UP CURB
Z-CLIP
NOTE(S):
1. SET Z-CLIP IN 3/4" BUTYL TAPE.
ATTACH W/#8 FLAT TRUSS HEAD,
GALV. STL. THREADED FASTERNER
AT 8# O.C.
BUILDING WRAP - FULLY FLASH CURB
- SEE SPECIFICATION 072500
SEAL ENDS OF Z-CLIP USING COLOR
MATCHING URETHANE SEALANT
M
IN
4" H1
FIRE TREATED WOOD NAILERS
2x6 TREATED WOOD BLOCKING
STRUCTURAL FRAMING, SEE
STRUCTURAL DRAWINGS
EDGE ANGLE, SEE
STRUCTURAL DRAWINGS
6" 4"
OPENING
PRE-MOLDED PIPE FLASHING
W/ALUMINUM BASE SET IN CONT.
BEAD OF URETHANE SEALANT
ø 1'-4 1/2"
PIPE CURB FLASHING BY METAL
ROOF PANEL MANUFACTURER, SEE
SPECIFICATION 074113.16
PANEL SUPPORT
FASTENER #1E 1/4"-14 X 1 1/4"
(5 FOR EACH PANEL)
1'
M
IN
M
AX
1'
FASTENER #1E 1/4"-14 X 1 1/4"
SPACED PER MANUFACTURER
RECOMMENDATIONS
P
LO
T
D A T E
P
LO
T T E D
B Y
C H K 'D
B Y
D E S
IG
N
O F F
IC
E
D E S
IG
N E D
B Y
P R O J E C T
N O
D R A W N
B Y
A P P R O V E D
B Y
U N
IT
E D
S T A T E S
D E P A R T M E N T
O F
T H E
IN
T E R
IO
R
B U R E A U
O F
L A N D
M A N A G E M E N T
D A T E
D E S C R
IP
T
IO
N
M A R K
A P P R O V E D
D A T E
SHEET OF
:3 :5
P M
C U s e rs a lf o n s o ra m ir e z D o c u m e n ts R e vi tL o c a lT e m p N W B L M D O a rc h a lf o n s o ra m ir e z .r vt
R O O F
D E T A
IL
S
A124
N W B L M D O
S H O S H O N E
F
IE
L D
O F F
IC
E
R E P L A C E M E N T
J R C
R H
C U S H
IN
G
T E R R E L L
J R C
B L M
.1 .2
T W
IN
F A L L S
D
IS
T R
IC
T
ID
A H O
64 124
NOT TO SCALEA124
4 DAYLIGHTING TUBE DETAILING
A124
3 TYPICAL PIPE PENETRATION DETAIL
10.50
SCALE IN FEET
A124
1 ROOF CURB - UPSLOPE SIDE
A124
2 ROOF CURB - DOW NSLOPE SIDE10.50
SCALE IN FEET
10.50
SCALE IN FEET
A124
5 LARGE PIPE PENETRATION DETAIL
STUCCO SYSTEM
PER SPECIFICATION
092400
CMU VENEER PER
SPECIFICATION
042613
MATERIALS LEGEND
STANDING SEAM METAL
ROOF PANEL PER
SPECIFICATION
074113.16
FIRST FLOOR
100'-0"
TOP OF WALL
113'-0"
A301
A301
A301
VE VE VE
VA
VC
A301
VE
VA VA VA
VE VE VE VEVE
VC VC VC VC VC VC VC VC VC VC VC
12 23 4
TY
P.
3'
5555555 55555
8 8 8 8 8 89
15689111314151617181920 234710
111111 12 1313 13
12' - 0"
E.Q.E.Q.E.Q.E.Q. EQEQ
FIRST FLOOR
100'-0"
TOP OF WALL
113'-0"
A301
VE VE VE VE VE VE VE VE
5 5 555555
ABCD
2 2 2 2
FIRST FLOOR
100'-0"
TOP OF WALL
113'-0"
A301
VE VE VE VEVE
5 5 5 5 5 8 8 9
A B C D
13222
VF
FIRST FLOOR
100'-0"
TOP OF WALL
113'-0"
A301
A301
A301
VEVEVEVEVD
A301
VE VE VE VE
VB VA VA
VE
6 6 6 6 6 6 6 6 6 68 98 8888
1 5 6 8 9 11 13 14 15 16 17 18 19
2 3 4 7 10
4'
6" TYP. SEE A601 6" TYP.
ALA
13 13 13 13 1311 1111
A311
TYP.
2 2 2 2
VFVFVFVF
22 6666
7'
6 6
A. SEE A100 FOR WALL ASSEMBLY AND ROOF TYPES.
B. SEE CIVIL AND LANDSCAPE DRAWINGS FOR ALL SITE RELATED
ITEMS ADJACENT TO THE BUILDING.
C. CONTROLS IN THE CMU VENEER ARE TO FOLLOW
SPECIFICATION 042613.
D. CONTROLS JOINTS IN THE STUCCO ARE TO FOLLOW
SPECIFICATION 092400.
E. SEE 'DOOR AND WINDOW SCHEDULE' SHEET, A601, FOR
DOOR AND WINDOWS TYPES.
F. SEE ROOF PLANS GUTTER AND DOWNSPOUT DRAIN
LOCATIONS.
G. SEE STRUCTURAL DRAWINGS FOR ALL T.O. WALL
MEASUREMENTS AND TOP OF STEEL MEASUREMENTS.
H. SEE 'DOOR AND WINDOW SCHEDULE' SHEET, A601, FOR
DETAILS AND TRIM LOCATIONS.
I. SEE ELECTRICAL DRAWINGS FOR ALL EXTERIOR LIGHTING AND
ELECTRICAL ITEMS.
J. SEE MECHANICAL DRAWINGS FOR ALL MECHANICAL
EQUIPMENT.
K. CONCRETE FOUNDATION STEM WALL TO BE COVERED WITH
CONCRETE FACED INSULATION BOARD, SEE WALL SECTIONS
AND DETAILS.
L. PAINT ALL EXPOSED STRUCTURAL STEEL PER SPECIFICATION
099113.
M. PAINT ALL EXPOSED MECHANICAL DIFFUSERS TO MATCH
ADJACENT SIDING COLOR.
GENERAL NOTES
P
LO
T
D A T E
P
LO
T T E D
B Y
C H K 'D
B Y
D E S
IG
N
O F F
IC
E
D E S
IG
N E D
B Y
P R O J E C T
N O
D R A W N
B Y
A P P R O V E D
B Y
U N
IT
E D
S T A T E S
D E P A R T M E N T
O F
T H E
IN
T E R
IO
R
B U R E A U
O F
L A N D
M A N A G E M E N T
D A T E
D E S C R
IP
T
IO
N
M A R K
A P P R O V E D
D A T E
SHEET OF
:2 :0
P M
C U s e rs a lf o n s o ra m ir e z D o c u m e n ts R e vi tL o c a lT e m p N W B L M D O a rc h a lf o n s o ra m ir e z .r vt
E X T E R
IO
R
E L E V A T
IO
N S
A201
N W B L M D O
S H O S H O N E
F
IE
L D
O F F
IC
E
R E P L A C E M E N T
J R C
R H
C U S H
IN
G
T E R R E L L
J R C
B L M
.1 .2
T W
IN
F A L L S
D
IS
T R
IC
T
ID
A H O
65 124
# SHEET NOTES
1 STUCCO CONTROL JOINT, TYPICAL. SEE A001 FOR DETAIL.
2 MASONRY CONTROL JOINT, SEALANT TO MATCH COLOR OF CMU
CONTROL JOINT VENEER. SEE STRUCTURAL DRAWINGS FOR CONTROL
JOINT DETAIL.
3 PLUMBING VENT, SEE PLUMBING DRAWINGS.
4 REGLET AND COUNTERFLASHING, SEE ROOF DETAILS ON A120'S
SHEETS.
5 VERTICAL SUN SHADE DEVICE, TO BE ' AGS Inc. P-375 ' 3/8" THICK
ALUMINUM PERFORATED PANELS WITH MANUFACTURER'S STANDARD
PERCENTAGE OF PERFORATION, COLOR TO MATCH HORIZONTAL SUN
SHADE DEVICE. SEE DETAILS ON A603.
6 HORIZONTAL SUN SHADE DEVICE,TO BE 'ARCHITECTURAL LOUVERS H6JN
- 6" DEEP 25 DEGREE NARROW N BLADE EXTRUDED ALUMINUM
STATIONARY SUNSHADE WITH 4" BLADE SPACING, STANDARD TRIM, AND
A BLACK ANODIZED FINISH' OR EQUAL. SEE DETAIL ON A603.
7 TUBULAR DAYLIGHTING DEVICE UNIT SKYLIGHT, SEE SPECIFICATIONS
AND ROOF DETAILS SHEET FOR FURTHER INFORMATION. SEE CEILING
PLAN FOR DAYLIGHT TUBE DIFFUSER LOCATIONS.
8 CMU VENEER AT COLUMN BASE WITH CONCRETE CAP.
9 PRIME AND PAINT ALL EXPOSED STEEL, SEE SPECIFICATION 099113.
10 SNOW GUARD, TYPICAL. SEE ROOF PLAN ON A121 AND SPECIFICATIONS
FOR FURTHER INFORMATION.
11 GUTTER DOWNSPOUT WITH ASSOCIATED GUTTER, COLOR TO MATCH
ROOFING COLOR.
12 ELECTRICAL EQUIPMENT, SEE ELECTRICAL DRAWINGS.
13 EXTERIOR LIGHT FIXTURE, SEE ELECTRICAL DRAWINGS.
A201
1 NORTH ELEVATION
A201
2 EAST ELEVATION
A201
3 WEST ELEVATION
A201
4 SOUTH ELEVATION
SCALE IN FEET
SCALE IN FEET
SCALE IN FEET
T ectonic Cop yright 2007
T ectonic Cop yright 2007T ectonic Cop yright 2007
FIRST FLOOR
100'-0"
A301
FIELD OFFICE/S.S./DISTRICT
STAFF
3" / 1'-0" 1" / 1'-0"
H1
H1
C
D D
C
A303
3______________
A303
SIM. SIM.
OPP.
C
B
A122
FIRST FLOOR
100'-0"
A301
ENTRY HALL
FIRE READY ROOM
WELLNESS
HALL
BREAK AREA
3" / 1'-0"
1" / 1'-0"
LOBBY/ENTRY
H1
H1
D
A302
A303
A A
B
B B
ABD
ALA
VC
VA
A122
A123
FIRST FLOOR
100'-0"
TOP OF W ALL
113'-0"
A301
FIRE SUITE
3" / 1'-0"
1" / 1'-0"
H1
H1
C
C
D D
A302
A303
BC
A123
A122
VE VE
FIRST FLOOR
100'-0"
TOP OF W ALL
113'-0"
A301
FIELD
OFFICE/S.S./DISTRICT
STAFF
FIRE SUITE
A301
A301
VC VC VC VC VC VC VC VC VC
A301
H1 H1
C
D
C
D
FIRE READY
ROOM
R.R.
R.R.
A303
A303
OPP.
VC VC VC
B
B
B 1,3
B
1 6 8 13 15 17 19 20
H1H1
B B
VE
FIRST FLOOR
100'-0"
A301
MAIN CONFERENCE ROOM
FIELD OFFICE
HUDDLE ROOM
PRIVATE OFFICE
PRIVATE OFFICE
SMALL CONFERENCE ROOM
FIELD OFFICE/S.S./DISTRICT
STAFF
C
D
H1
H1
3" / 1'-0"
1" / 1'-0"
A302
A303
SIM.
A303
A
A A
B 1 A
ABD
VF
B 1,3
A122
P
LO
T
D A T E
P
LO
T T E D
B Y
C H K 'D
B Y
D E S
IG
N
O F F
IC
E
D E S
IG
N E D
B Y
P R O J E C T
N O
D R A W N
B Y
A P P R O V E D
B Y
U N
IT
E D
S T A T E S
D E P A R T M E N T
O F
T H E
IN
T E R
IO
R
B U R E A U
O F
L A N D
M A N A G E M E N T
D A T E
D E S C R
IP
T
IO
N
M A R K
A P P R O V E D
D A T E
SHEET OF
:4 :2
P M
C U s e rs a lf o n s o ra m ir e z D o c u m e n ts R e vi tL o c a lT e m p N W B L M D O a rc h a lf o n s o ra m ir e z .r vt
B U
IL
D
IN
G
S E C T
IO
N S
A301
N W B L M D O
S H O S H O N E
F
IE
L D
O F F
IC
E
R E P L A C E M E N T
J R C
R H
C U S H
IN
G
T E R R E L L
J R C
B L M
.1 .2
T W
IN
F A L L S
D
IS
T R
IC
T
ID
A H O
66 124
A301
1 BUILDING SECTION I
A301
2 BUILDING SECTION II
A301
3 BUILDING SECTION III
A301
4 BUILDING SECTION V
SCALE IN FEET
SCALE IN FEET
SCALE IN FEET
SCALE IN FEET
A301
5 BUILDING SECTION IV
FIRST FLOOR
100'-0"
LOBBY/ENTRY
H1
D
A602
A602
A122
METAL SOFFIT PANELS,
TYPICAL AT ALL SOFFITS.
SEE SPECIFICATION
074293. COLOR TO
MATCH COLOR OF
ROOFING PANELS
PRE-FINISHED METAL
GUTTER AND
DOWNSPOUT, SEE
SPECIFICATION
074113.16 AND DETAILS
ON A123
PRIME AND PAINT ALL
EXPOSED EXTERIOR
STEEL, SEE EXTERIOR
PAINT SPECIFICATION
099113
SEE DETAILS ON A311
FOR COLUMN WRAP
DETAILS
ALA
DOWNSPOUT TO HUG
COLUMN AND BASE AS
CLOSE AS POSSIBLE.
A123
SIM
C
FIRST FLOOR
100'-0"
FIRE SUITE
C
D
H1
C
A311
SIM
A602
A602
A122
METAL SOFFIT PANELS,
TYPICAL AT ALL SOFFITS.
SEE SPECIFICATION
074293. COLOR TO
MATCH COLOR OF
ROOFING PANELS
PRE-FINISHED METAL
GUTTER AND
DOWNSPOUT, SEE
SPECIFICATION
074113.16 AND
DETAILS ON A123
PRIME AND PAINT ALL
EXPOSED EXTERIOR
STEEL, SEE EXTERIOR
PAINT SPECIFICATION
099113
SEE DETAILS ON A311
FOR COLUMN WRAP
DETAILS
VE
6'
TY
P.
3'
DOWNSPOUT TO HUG
COLUMN AND BASE AS
CLOSE AS POSSIBLE.
A123
FIRST FLOOR
100'-0"
MAIN CONFERENCE ROOM
FIELD OFFICE
H1
D
A602
A311
SIM
A123
A602
VF
D
6'
TY
P.
3'
A. SEE CIVIL, STRUCTURAL, MECHANICAL, AND ELECTRICAL
DRAWINGS FOR ADDITIONAL REQUIREMENTS AND
COORDINATION.
B. SEE FIRE DRAWINGS FOR ADDITIONAL WORK TO OCCUR AND
ADDITIONAL REQUIREMENTS.
C. SEE A001 AND A101 FOR WALL TYPE INFORMATION AND
LOCATIONS.
D. SEE CODE PLAN FOR INFORMATION ON SQUARE FOOTAGE OF
BUILDING AND OTHER RELATED ITEMS.
E. SEE CODE PLAN FOR ENVELOPE ENERGY REQUIREMENTS.
F. SEE SPECIFICATIONS FOR ALL BUILDING COMPONENTS.
G. SEE EXTERIOR ELEVATIONS ON A201 FOR LOCATIONS OF CMU
VENEER AT BASE OF EXTERIOR WALLS.
H. COORDINATE EXTERIOR WALL DIMENSIONS AND FACE OF STEM
WALL LOCATIONS WITH STRUCTURAL DRAWINGS.
I. DIMENSIONS OF WINDOWS LOCATED WITHIN STUCCO ARE TO
CENTERLINE OF WINDOW. DIMENSIONS TO WINDOWS AND
FRAMES LOCATED WITHIN CMU VEENER ARE TO OUTSIDE OF
ROUGH OPENING.
J. SEE FINISH PLAN ON A501 FOR COORDINATION OF FINISHES
AND OTHER ITEMS MOUNTED ON INTERIOR WALLS.
K. SEE A501 FOR ROLLER SHADE LOCATIONS.
L. PROVIDE METAL STUD BLOCKING IN WALL AS NEEDED FOR
ALL MOUNTED EQUIPMENT, MILLWORK, AND HARDWARE,
COORDINATE WITH WALL TYPES.
GENERAL NOTES
P
LO
T
D A T E
P
LO
T T E D
B Y
C H K 'D
B Y
D E S
IG
N
O F F
IC
E
D E S
IG
N E D
B Y
P R O J E C T
N O
D R A W N
B Y
A P P R O V E D
B Y
U N
IT
E D
S T A T E S
D E P A R T M E N T
O F
T H E
IN
T E R
IO
R
B U R E A U
O F
L A N D
M A N A G E M E N T
D A T E
D E S C R
IP
T
IO
N
M A R K
A P P R O V E D
D A T E
SHEET OF
:3 :2
P M
C U s e rs a lf o n s o ra m ir e z D o c u m e n ts R e vi tL o c a lT e m p N W B L M D O a rc h a lf o n s o ra m ir e z .r vt
W A L L
S E C T
IO
N S
A302
N W B L M D O
S H O S H O N E
F
IE
L D
O F F
IC
E
R E P L A C E M E N T
J R C
R H
C U S H
IN
G
T E R R E L L
J R C
B L M
.1 .2
T W
IN
F A L L S
D
IS
T R
IC
T
ID
A H O
67 124
A302
2 W ALL SECTION II
A302
1 W ALL SECTION I
A302
3 W ALL SECTION III
SCALE IN FEET
SCALE IN FEET
FIRST FLOOR
100'-0"
FIRE SUITE
C
D
H1
A311
SIM
A122
A311
TY
P.
3'
FIRST FLOOR
100'-0"
HUDDLE ROOM
C
H1
H1
B 1,3
B
A122
A122
FIRST FLOOR
100'-0"
FIRE SUITE
C
D
H1
A122
A602
A602
A311
SIM
6'
TY
P.
3'
FIRST FLOOR
100'-0"
BREAK AREA
D
H1
D
A
A602
A311
SIM
A602
A122
METAL SOFFIT PANELS,
TYPICAL AT ALL SOFFITS.
SEE SPECIFICATION
074293. COLOR TO
MATCH COLOR OF
ROOFING PANELS
PRE-FINISHED METAL
GUTTER AND
DOWNSPOUT, SEE
SPECIFICATION
074113.16 AND
DETAILS ON A123
PRIME AND PAINT ALL
EXPOSED EXTERIOR
STEEL, SEE EXTERIOR
PAINT SPECIFICATION
099113
A311
SEE DETAILS ON A311
FOR COLUMN WRAP
DETAILS
4'
TY
P.
3'
DOWNSPOUT TO HUG
COLUMN AND BASE AS
CLOSE AS POSSIBLE.
A123
A. SEE CIVIL, STRUCTURAL, MECHANICAL, AND ELECTRICAL
DRAWINGS FOR ADDITIONAL REQUIREMENTS AND
COORDINATION.
B. SEE FIRE DRAWINGS FOR ADDITIONAL WORK TO OCCUR AND
ADDITIONAL REQUIREMENTS.
C. SEE A001 AND A101 FOR WALL TYPE INFORMATION AND
LOCATIONS.
D. SEE CODE PLAN FOR INFORMATION ON SQUARE FOOTAGE OF
BUILDING AND OTHER RELATED ITEMS.
E. SEE CODE PLAN FOR ENVELOPE ENERGY REQUIREMENTS.
F. SEE SPECIFICATIONS FOR ALL BUILDING COMPONENTS.
G. SEE EXTERIOR ELEVATIONS ON A201 FOR LOCATIONS OF CMU
VENEER AT BASE OF EXTERIOR WALLS.
H. COORDINATE EXTERIOR WALL DIMENSIONS AND FACE OF STEM
WALL LOCATIONS WITH STRUCTURAL DRAWINGS.
I. DIMENSIONS OF WINDOWS LOCATED WITHIN STUCCO ARE TO
CENTERLINE OF WINDOW. DIMENSIONS TO WINDOWS AND
FRAMES LOCATED WITHIN CMU VEENER ARE TO OUTSIDE OF
ROUGH OPENING.
J. SEE FINISH PLAN ON A501 FOR COORDINATION OF FINISHES
AND OTHER ITEMS MOUNTED ON INTERIOR WALLS.
K. SEE A501 FOR ROLLER SHADE LOCATIONS.
L. PROVIDE METAL STUD BLOCKING IN WALL AS NEEDED FOR
ALL MOUNTED EQUIPMENT, MILLWORK, AND HARDWARE,
COORDINATE WITH WALL TYPES.
GENERAL NOTES
P
LO
T
D A T E
P
LO
T T E D
B Y
C H K 'D
B Y
D E S
IG
N
O F F
IC
E
D E S
IG
N E D
B Y
P R O J E C T
N O
D R A W N
B Y
A P P R O V E D
B Y
U N
IT
E D
S T A T E S
D E P A R T M E N T
O F
T H E
IN
T E R
IO
R
B U R E A U
O F
L A N D
M A N A G E M E N T
D A T E
D E S C R
IP
T
IO
N
M A R K
A P P R O V E D
D A T E
SHEET OF
:4 :3
P M
C U s e rs a lf o n s o ra m ir e z D o c u m e n ts R e vi tL o c a lT e m p N W B L M D O a rc h a lf o n s o ra m ir e z .r vt
W A L L
S E C T
IO
N S
A303
N W B L M D O
S H O S H O N E
F
IE
L D
O F F
IC
E
R E P L A C E M E N T
J R C
R H
C U S H
IN
G
T E R R E L L
J R C
B L M
.1 .2
T W
IN
F A L L S
D
IS
T R
IC
T
ID
A H O
68 124
A303
1 W ALL SECTION IV
A303
2 W ALL SECTION V
A303
3 W ALL SECTION VI
A303
4 W ALL SECTION VII
SCALE IN FEET
SCALE IN FEET
SCALE IN FEET
SELF ADHERING THROUGH WALL
FLASHING. LAP UP WALL
WEEPS AT BOTTOM OF MASONRY
VENEER. SPACING AT 24" O.C., SEE
SPECIFICATION 042000
CAVITY DRAINAGE MATERIAL
LIQUID FLASHING TO LAP OVER
METAL FLASHING - INSTALL
SHEATHING PER MANUFACTURER
WRITTEN INSTRUCTIONS
6" STEEL STUD
FRAMING
CONCRETE SLAB ON
GRADE, SEE STRUCTURAL
DRAWINGS, SEE FINISH
PLAN FOR FLOORING
FINISHES
BASE COURSE. SEE
GEOTECHNICAL SOILS
REPORT
BITUMINOUS
DAMP PROOFING
SILL PLATE GASKETING
CONCRETE STEM WALL
PER STRUCTURAL
DRAWINGS
1/2" EXPANSION JOINT,
SEE STRUCTURAL
DRAWINGS
INTERIOREXTERIOR
FULLY GROUT
BEHIND CMU VENEER
BELOW GRADE
GROUT CELLS SOLID
BELOW GRADE
EXPANSION JOINT, SEE
CIVIL DRAWINGS
EXTERIOR PAVING WHERE
OCCURS, SEE CIVIL
DRAWINGS FOR LOCATIONS
AND FINISH GRADE
ELEVATIONS
VAPOR BARRIER BENEATH
CONCRETE SLAB - SEE
S002 FOR BARRIER
INFORMATION
BE
LO
W F
FE
4"
SEE EXTERIOR ELEVATIONS
T.O. CMU
INTERIOR
CONTINUOUS PRE-FINISHED
METAL FLASHING LAPS BEHIND
FLEXIBLE FLASHING - SLOPE
METAL FLASHING
1/4" = 1'-0" TO DRAIN
CASING BEAD WITH
WEEP HOLES
8"X4"X16" UNIT
MASONRY VENEER SILL
UNIT
EXTERIOR
C
D
SEALANT
LIQUID FLASHING TO LAP
OVER METAL FLASHING -
INSTALL PER SHEATHING
MANUFACTURER WRITTEN
INSTRUCTIONS
1/2" 4"
1/2"
1/2" 1/2"
STRUCTURAL STEEL
COLUMN, SEE
STRUCTURAL DRAWINGS.
PRIME AND PAINT ALL
EXPOSED STEEL
SEALANT AT ALL SIDES
OF CONCRETE CAP TO
STEEL TRANSTION
PRECAST CONCRETE
COLUMN CAP SET IN BED
OF MORTAR
1/2" X 4" 316
STAINLESS STEEL
THREADED ROD SET
MORTAR
1/8" KERF AT ALL SIDES
OF COLUMN CAP
4" DEEP X 4" HIGH X 16"
LONG GROUND FACE CMU
BLOCK WITH FULLY
GROUTED CELLS, SEE
STRUCTURAL DRAWINGS FOR
FURTHER INFORMATION
2" 2"
FILL VOID WITH CONRETE
PER STRUCUTRAL DRAWINGS
EQ EQ
JOINT SEALANT AND
BACKING
CMU VENEER
CORNER BLOCK
D
C
SEE: A001 FOR
WALL ASSEMBLIES
P
LO
T
D A T E
P
LO
T T E D
B Y
C H K 'D
B Y
D E S
IG
N
O F F
IC
E
D E S
IG
N E D
B Y
P R O J E C T
N O
D R A W N
B Y
A P P R O V E D
B Y
U N
IT
E D
S T A T E S
D E P A R T M E N T
O F
T H E
IN
T E R
IO
R
B U R E A U
O F
L A N D
M A N A G E M E N T
D A T E
D E S C R
IP
T
IO
N
M A R K
A P P R O V E D
D A T E
SHEET OF
:0 :1
P M
C U s e rs a lf o n s o ra m ir e z D o c u m e n ts R e vi tL o c a lT e m p N W B L M D O a rc h a lf o n s o ra m ir e z .r vt
W A L L
D E T A
IL
S
A311
N W B L M D O
S H O S H O N E
F
IE
L D
O F F
IC
E
R E P L A C E M E N T
J R C
R H
C U S H
IN
G
T E R R E L L
J R C
B L M
.1 .2
T W
IN
F A L L S
D
IS
T R
IC
T
ID
A H O
69 124
A311
3 TYPICAL FOUNDATION SILL DETAIL
SCALE IN FEET
A311
2 TYPICAL CMU SILL TO STUCCO TRANSITION
SCALE IN FEET
A311
1 TYPICAL COLUMN CAP DETAIL
10.50
SCALE IN FEET
A311
5 TYPICAL STUCCO TO CMU VENEER TRANSITION
10.50
SCALE IN FEET
N
O C
D D
C o m m e n t
.0
.2
RB1
RB1
RB1
RB1
RB1
P T
P T
PT4
PT4
PT5
PT3
PT4
PT4
W T
W T
W T
W T
WT5
WT2
WT2
WT4
WT3
WT2
PT5
WT2 WT2
WT2
WT1
WT6
WT5
WT4
WT3
WT2
WT6
WT2 WT2
T B
T B
WT2
WT1
WT2
WT1
WT2
WT1
EXTENT OF ACCENT PAINT OR WALL FINISHES
FLOOR FINISH 'SC1'
SEALED CONCRETE
LOCATION AND TYPE OF CORNER GUARDS
CG
FINISH PLAN LEGEND
FLOORING MATERIAL CHANGE, MATERIAL TYPES
SHOWN ON EACH SIDE OF TRANSITION
ROOM NAME AND NUMBER
FLOOR FINISH 'LVT1'
LUXURY VINYL TILE
FLOOR FINISH 'CP1'
CARPET TILE
INSTALL DIRECTION OF DIRECTIONAL FLOOR FINISH
FINISH TAG
A8## # INTERIOR ELEVATION CALLOUT AND
DIRECTION OF ELEVATION VIEW
NAME
FINISH TAGS DISPLAYED IN GROUPING ON FINISH PLAN
REPRESENT MAJORITY ROOM FINISH SELECTIONS. ORDER OF
GROUPING DEFINED IN EXAMPLE BELOW:
MAJORITY WALL FINISH
MAJORITY BASE FINISH
MAJORITY FLOOR FINISH
FLOORING
BASE
RB1 RUBBER BASE 4" - SEE SPECIFICATION 096513
RB2 RUBBER BASE 6" - SEE SPECIFICATION 096513
TB1 TILE BASE - SEE SPECIFICATION 093013
WALLS
FRP1 FIBERGLASS PANELS - SEE SPECIFICATION 066400
PT# PAINT - SEE SPECIFICATION 099123
WT1 WALL TILE - SEE SPECIFICATION 093013
FLOORING TRANSITIONS
TR1 SC TO CP/LV
TR2 CP TO FT
CASEWORK
PL# PLASTIC LAMINATE - SEE SPECIFICATION 064116 AND
SEPCIFICATION 123623.13
ROOM FINISH ABBREVIATIONS
CP1 CARPET TILE - SEE SPECIFICATION 096813
CP2 WALK OFF CARPET - SEE SPECIFICATION 096813
FT1 FLOOR TILE - SEE SPECIFICATION 093013
LVT1 LUXURY VINYL TILE - SEE SPECIFICATION 096519
SC1 SEALED CONCRETE WITH STAIN - SEE SPECIFICATION 033500
FLOOR FINISH 'CP2'
WALK OFF CARPET
FLOOR FINISH 'FT1'
FLOOR TILE
GENERAL FINISH NOTES
A. MOTORIZED ROLLER SHADES TO BE PROVIDED AT EACH OF THE
FIRE READY ROOM CLERESTORY WINDOWS, SEE ROLLER SHADE
SPECIFICATION 122413.
ENTRY HALL
I.T./PACS
ROOM
HUDDLE
ROOM
WELLNESS
M.R.R.
W.R.R.
111 PRIVATE
OFFICE
HUDDLE
ROOM
PRIVATE
OFFICE
HUDDLE
ROOM
FIRE READY
ROOM
HUDDLE
ROOM
FOCUS
ROOM
FIRE SUITE
MEP
BREAK
AREA
SMALL
CONFERENCE
ROOM
FIELD
OFFICE/S.S./DISTRICT
STAFF
JAN.
STAFF
VESTIBULE
STAFF
VESTIBULE
VESTIBULE
OFFICE
SUPPLY/PLOTTER
ROOM
RECEPTION
LOBBY/ENTRY
MAIN
CONFERENCE
ROOM FIELD
OFFICE
MAIL ROOM
R.R.
R.R.
HALL
RS1RS1RS1RS1
RS1
RS1
RS1
RS1
RS1
RS1 RS1 RS1 RS1
RS1 RS1
RS1 RS1 RS1 RS1 RS1
RS1 RS1 RS1 RS1 RS1
RS1
RS1RS1
RS1
RS1
RS1
RS1
RS1
RS1
RS1
RS1
RS1
RS1
RS1
RS1
RS1
SMALL
CONFERENCE
ROOM
CG
CG
CG
CG CG CG
CGCG
CG
CG
CG
CGCG
CG
CG
CGCG
CG
CG
CG
CG
CG
IT STRG.
117A 1
CG CG CG CG
CG CG
RS1RS1RS1
CG
FIELD
OFFICE/S.S./DISTRICT
STAFF
CG
CGCG
CG
P
LO
T
D A T E
P
LO
T T E D
B Y
C H K 'D
B Y
D E S
IG
N
O F F
IC
E
D E S
IG
N E D
B Y
P R O J E C T
N O
D R A W N
B Y
A P P R O V E D
B Y
U N
IT
E D
S T A T E S
D E P A R T M E N T
O F
T H E
IN
T E R
IO
R
B U R E A U
O F
L A N D
M A N A G E M E N T
D A T E
D E S C R
IP
T
IO
N
M A R K
A P P R O V E D
D A T E
SHEET OF
:4 :3
P M
C U s e rs a lf o n s o ra m ir e z D o c u m e n ts R e vi tL o c a lT e m p N W B L M D O a rc h a lf o n s o ra m ir e z .r vt
F
IN
IS
H
P L A N
A501
N W B L M D O
S H O S H O N E
F
IE
L D
O F F
IC
E
R E P L A C E M E N T
J R C
R H
C U S H
IN
G
T E R R E L L
J R C
B L M
.1 .2
T W
IN
F A L L S
D
IS
T R
IC
T
ID
A H O
70 124
# KEYNOTES
1 WALLS TO RECEIVE FRP1 UP TO 48" A.F.F. (ABOVE FINISH FLOOR).
2 WALL MOUNTED WHITEBOARD, (VISUAL DISPLAY UNIT) VDU1, WHERE
NOTED. MOUNT 2'-10" ABOVE FINISH FLOOR. SEE SPECIFICATIONS
FOR FURTHER INFORMATION.
3 UPPER CLERESTORY WINDOWS WITHIN ROOM NOTED ARE ALL TO
RECIEVE MOTORIZED ROLLER SHADES. SEE ROOF PLAN FOR WINDOW
LOCATIONS AND ELECTRICAL DRAWINGS FOR CONNECTIONS.
A501
1 FINISH PLAN
NORTH REF
SCALE IN FEET
ROOM FINISH SCHEDULE
ROOM
NUMBER
ROOM
NAME
FLOOR BASE
WALLS
ADDITIONAL NOTES
NORTH EAST SOUTH WEST
117 I.T./PACS ROOM SC1 RB1 PT1 PT1 PT1 PT1
117A IT STRG. SC1 RB1 PT1 PT1 PT1 PT1
118 HUDDLE ROOM CP1 RB1 PT1 PT1 PT1 PT1
119 SMALL CONFERENCE ROOM CP1 RB1 PT1 PT1 PT1 PT1
120 STAFF VESTIBULE CP2 RB1 PT1 PT1 PT1 PT1
121 HUDDLE ROOM CP1 RB1 PT1 PT1 PT1 PT1
122 FIRE SUITE CP1 RB1 PT1 PT1 PT1 PT1
123 HUDDLE ROOM CP1 RB1 PT1 PT1 PT1 PT1
124 FOCUS ROOM CP1 RB1 PT1 PT1 PT1 PT1
125 FIRE READY ROOM CP1/LVT
RB1 PT1 PT1 PT1 PT1
126 VESTIBULE CP2 RB1 PT1 PT1 PT1 PT1
127 MAIL ROOM CP1 RB1 PT1 PT1 PT1 PT1
128 OFFICE SUPPLY/PLOTTER ROOM CP1 RB1 PT1 PT1 PT1 PT1
129 RECEPTION CP1 RB1 PT1 PT1 PT1 PT1
130 R.R. FT1 TB1/TR# PT1/WT1 PT1/WT1 PT1/WT1 PT1/WT1
131 R.R. FT1 TB1/TR# PT1/WT1 PT1/WT1 PT1/WT1 PT1/WT1
132 MAIN CONFERENCE ROOM FIELD OFFICE CP1 RB1 PT1 PT1 PT1 PT1
ROOM FINISH SCHEDULE
ROOM
NUMBER
ROOM
NAME
FLOOR BASE
WALLS
ADDITIONAL NOTES
NORTH EAST SOUTH WEST
101 LOBBY/ENTRY CP2 RB1 PT1 PT1 PT1 PT1
102 ENTRY HALL CP1 RB1 PT1 PT1 PT1 PT1
103 FIELD OFFICE/S.S./DISTRICT STAFF CP1 RB1 PT1 PT1 PT1 PT2
104 FIELD OFFICE/S.S./DISTRICT STAFF CP1 RB1 PT1 PT1 PT1 PT1
105 HUDDLE ROOM CP1 RB1 PT1 PT1 PT1 PT1
106 PRIVATE OFFICE CP1 RB1 PT1 PT1 PT1 PT1
107 PRIVATE OFFICE CP1 RB1 PT1 PT1 PT1 PT1
108 SMALL CONFERENCE ROOM CP1 RB1 PT1 PT1 PT1 PT1
109 STAFF VESTIBULE CP2 RB1 PT1 PT1 PT1 PT1
110 M.R.R. FT1 TB1/TR# PT1/WT1/WT2 PT1/WT1/WT2 PT1/WT1/WT2 PT1/WT1/WT2
111 W.R.R. FT1 TB1/TR# PT1/WT1/WT2 PT1/WT1/WT2 PT1/WT1/WT2 PT1/WT1/WT2
112 HALL CP1 RB1 PT1 PT1 PT1 PT1
113 MEP SC1 RB2 PT1 PT1 PT1 PT1
114 BREAK AREA LVT1 RB1 PT1 PT1 PT1/WT3/WT4/WT5/WT6/W
T7
PT1
115 JAN. SC1 RB2 PT1/FRP1 PT1/FRP1 PT1 PT1
116 WELLNESS CP1 RB1 PT1 PT1 PT1/WT2 PT1
DOOR NOTES
1. DOOR TO HAVE 180 DEGREE OPENING DOOR SWING.
2. DOOR AND FRAME ARE LOCATED ON THE INTERIOR OF THE
BUILDING.
3. DOOR TO RECIEVE POSITION SENSOR PER ELECTRICAL DRAWINGS.
4. DOOR TO BE UNDERCUT FOR MECHANICAL AIR TRANSFER.
5. RIM EXIT DEVICE TO HAVE TRIM WITH KEY CONTROL LEVER ON
THE EXTERIOR. KEYED LOCKSET TO BE USED FOR EMERGENCIES IN
EVENT OF A PACS SYSTEM FAILURE - COORDINATE KEYING WITH
GOVERNMENT.
HARDWARE GROUPSABBREVIATIONS
AL ALUMINUM
HM HOLLOW METAL
IHM INSULATED HOLLOW METAL
IN 1" INSULATED TEMPERED GLAZING
T 1/4" TEMPERED GLAZING
WD SOLID CORE WOOD
FF FACTORY FINISH
PT# PAINT (REFERENCE INTERIOR/EXTERIOR PAINT SPECIFICATION)
SET 1
• LOCK SET (OFFICE)
• HINGES
• WALL STOP
• SILENCER
SET 2
• LOCK SET (STOREROOM)
• HINGES
• WALL STOP
• SILENCER
• MANUAL FLUSH BOLT AT
TOP AND BOTTOM AT
PAIRS OF DOORS ON
FIXED LEAF
SET 3
• PASSAGE LATCH
• HINGES
• WALL STOP
• SILENCER
• SURFACE CLOSER
SET 4
• LOCK SET (BATH)
• HINGES
• WALL STOP
• SILENCER
SET 5
• LOCK SET (STOREROOM)
• HINGES
• WEATHERSTRIP
• THRESHOLD
SET 6
• OFFSET HINGES (SECURITY WITH
NON-REMOVABLE PINS AND
SECURITY STUD) -
• RIM EXIT DEVICE
• SURFACE CLOSER
• THRESHOLD
• AUTOMATIC DOOR OPERATOR
• POWER SUPPLY
• ACTUATION SWITCHES
• DOOR POSITION SENSOR
• STRIKE PLATE PROTECTOR
SET 7
• SECURITY HINGES WITH NON-
REMOVABLE PINS AND SECURITY
STUD
• EPT-10 POWER TRANSFER
• ELECTRIC RIM EXIT DEVICE
• SURFACE CLOSER
• FLOOR STOP
• SECURE CARD ACCESS, J-BOX
FOR ELECTRIFIED DOOR
HARDWARE FUNCTION
• DOOR POSITION SENSOR
• STRIKE PLATE PROTECTOR
• WEATHERSTRIP
• SWEEP
• THRESHOLD
SET 8
• OFFSET HINGES (SECURITY WITH
NON-REMOVABLE PINS AND
SECURITY STUD) -
• RIM EXIT DEVICE
• SURFACE CLOSER
• THRESHOLD
• AUTOMATIC DOOR OPERATOR
• POWER SUPPLY
• ACTUATION SWITCHES
• DOOR POSITION SENSOR
• STRIKE PLATE PROTECTOR
• WEATHERSTRIP
• SWEEP
• THRESHOLD
SET 9
• LOCK SET - LEVER - ELECTRIFIED
MORTISE LOCK (FAIL SECURE)
• SECURITY HINGES WITH NON-
REMOVABLE PINS AND SECURITY
STUD (WITH ELECTRIC MIDDLE
HINGE)
• POWER TRANSFER DEVICE
• SECURE CARD ACCESS, J-BOX
FOR ELECTRIFIED DOOR HARDWARE
• FUNCTION
• SURFACE CLOSER
• WALL STOP
• SILENCER
• DOOR POSITION SENSOR
• STRIKE PLATE PROTECTOR
SET 10
• RIM EXIT DEVICE
• HINGES
• SILENCER
• CLOSER
• WALL STOP
SET 11
• ELECTRIC RIM EXIT DEVICE
• SECURITY HINGES WITH NON-
REMOVABLE PINS AND SECURITY
STUD (WITH ELECTRIC MIDDLE
HINGE)
• POWER TRANSFER DEVICE
• SECURE CARD ACCESS, J-BOX
FOR ELECTRIFIED DOOR HARDWARE
• SURFACE CLOSER
• WALL STOP
• SILENCER
• DOOR POSITION SENSOR
• STRIKE PLATE PROTECTOR
A. FOR FRAME TYPE LOCATIONS, SEE FLOOR PLAN SHEETS.
B. FOR ALUMINUM FRAMED HARDWARE GROUPS, SEE SPECIFICATION
DIVISION 8, SECTION "ALUMINUM - FRAMED ENTRANCES AND
STOREFRONTS." FOR ALL OTHER OPENING HARDWARE GROUPS, SEE
SPECIFICATION DIVISION 8, SECTION "DOOR HARDWARE."
C. FIELD VERIFY ALL ROUGH OPENING DIMENSIONS PRIOR TO
FABRICATION/ INSTALLATION.
D. PROVIDE ONE ELECTRICAL CONDUIT RUN FROM DOOR STRIKE TO
ABOVE ADJACENT CEILING SPACE AS NEEDED FOR DOORS TO
RECEIVE ELECTRIC HARDWARE. REFERENCE ELECTRICAL DRAWINGS FOR
ALL ELECTRIFIED DOOR HARDWARE ITEMS.
E. PAINT ALL HOLLOW METAL DOORS AND FRAMES PER SPECIFICATION
DIVISION 9.
F. 'AC' AT THE END OF THE DOOR NUMBER INDICATES DOOR TO HAVE
ACCESS CONTROL, SEE HARDWARE GROUP, SPECIFICATIONS AND
ELECTRICAL DRAWINGS FOR FURTHER INFORMATION.
HOLLOW METAL DOORS AND DOOR FRAMES ARE TO BE INSULATED AT
ALL EXTERIOR DOOR LOCATIONS.
GENERAL NOTES
VA VB VC
VINYL WINDOW TYPE ELEVATIONS
4' - 0"
4'
3'
3' - 4"
4'
3'
2'
SE
E
EL
EV
AT
IO
N S
4' - 6"
VE
4' - 6"
2'
4'
3'
VD
3' - 0"
2'
4'
3'
"1
VF
3'
4'
2'
4' - 0"
*NOTE: ALL EXTERIOR WINDOWS TO USE INSULATED LAMINATED GLASS (GL-3), EXCEPT FOR WINDOW TYPE 'VC'.
WINDOW TYPE 'VC' TO USE INSULATED GLASS (GL-2).
A B C
DOOR TYPES
SEE SCHED.
SE
E
SC
H
ED
SE
E
SC
H
ED
SEE SCHED.
SE
E
SC
H
ED
SEE SCHED.
3'
2'
1'
8" 8"
1 2
HOLLOW METAL DOOR
FRAME TYPES
*NOTE: 4" HEAD OF FRAME
AT FRAMES IN EXTERIOR
VENEER LOCATIONS
2" SEE SCHED. 2"
2"
SE
E
SC
H
ED
2" SEE SCHED. 2"
1' - 6" 2"
2"
SE
E
SC
H
ED
3"
2"
SEE SCHED.
2" 1' - 6" 2"
2" 1'
4"
SE
E
SC
H
ED
3"
T T
2" SEE SCHED. 2"
1' - 0"
2"
2"
SE
E
SC
H
ED
3"
T
SE
E
SC
H
ED
4"
4" SEE SCHED. 4"
STOREFRONT FRAME TYPE ELEVATIONS
ALA
IN
IN IN
IN
IN IN
10' - 4"
9'
2"
1' - 8"
2"
3' - 0"
2"
3' - 0"
2"
1' - 10"
2"
2"
2'
2"
6'
0"
2"
4" 2'
7"
ALB
10' - 4"
9'
*INTERIOR DOOR AND FRAME
T T T
T T
T
2"
EQ
2"
2' - 11"
2"
2' - 11"
2"
EQ
2"
2"
2'
2"
6'
0"
2" H
INTERIOR ALUMINUM FRAMES
2'
3'
1"
4' - 0"
*NOTE: WINDOW TYPE 'H' TO BE 'CRL HORIZONTAL SLIDING DAISY MODEL PASS-THRU
ASSEMBLY WITH D4 OVERHEAD TRACK WITH JAMBS' OR EQUAL. FRAME COLOR TO BE SATIN
ANODIZED. PROVIDE ASSOCIATED KETED LOCK AND NECESSARY GLAZING. INSTALL PER
MANUFACTURER RECOMMENDATIONS AND INSTRUCTIONS. KEYING TO BE TIED INTO OVERALL
BUILDING KEY SYSTEM.
P
LO
T
D A T E
P
LO
T T E D
B Y
C H K 'D
B Y
D E S
IG
N
O F F
IC
E
D E S
IG
N E D
B Y
P R O J E C T
N O
D R A W N
B Y
A P P R O V E D
B Y
U N
IT
E D
S T A T E S
D E P A R T M E N T
O F
T H E
IN
T E R
IO
R
B U R E A U
O F
L A N D
M A N A G E M E N T
D A T E
D E S C R
IP
T
IO
N
M A R K
A P P R O V E D
D A T E
SHEET OF
:4 :1
P M
C U s e rs a lf o n s o ra m ir e z D o c u m e n ts R e vi tL o c a lT e m p N W B L M D O a rc h a lf o n s o ra m ir e z .r vt
D O O R
A N D
W
IN
D O W
S C H E D U L E S
A N D
D E T A
IL
S
A601
N W B L M D O
S H O S H O N E
F
IE
L D
O F F
IC
E
R E P L A C E M E N T
J R C
R H
C U S H
IN
G
T E R R E L L
J R C
B L M
.1 .2
T W
IN
F A L L S
D
IS
T R
IC
T
ID
A H O
71 124
DOOR SCHEDULE
DOOR
NUMBER
ROOM
NUMBER
ROOM NAME
DOOR FRAME HARDWARE
DOOR
NUMBER
SIZE
MTL TYPE
FINISH
GLAZE NOTES MTL TYPE
FRAME
FINISH
GROUP
W H T
101-1 101 LOBBY/ENTRY 3'-0" 7'-0" 1 3/4" AL C FF IN 3 AL ALA FF 8 101-1
101-2 101 LOBBY/ENTRY 3'-0" 7'-0" 1 3/4" AL C FF IN 3 AL ALA FF 8 101-2
101-3 101 LOBBY/ENTRY 6'-0" 7'-0" 1 3/4" AL C FF T 3 AL ALB FF 6 101-3
103-1 103 FIELD OFFICE/S.S./DISTRICT STAFF 3'-0" 7'-0" 1 3/4" WD B FF T HM 1 PT2 10 103-1
104-1AC 104 FIELD OFFICE/S.S./DISTRICT STAFF 3'-0" 7'-0" 1 3/4" WD B FF T 3 HM 1 PT2 11 104-1AC
105-1 105 HUDDLE ROOM 3'-0" 7'-0" 1 3/4" WD A FF - HM 3 PT2 1 105-1
106-1 106 PRIVATE OFFICE 3'-0" 7'-0" 1 3/4" WD A FF - HM 3 PT2 1 106-1
107-1 107 PRIVATE OFFICE 3'-0" 7'-0" 1 3/4" WD A FF - HM 3 PT2 1 107-1
108-1 108 SMALL CONFERENCE ROOM 3'-0" 7'-0" 1 3/4" WD A FF - HM 2 PT2 3 108-1
109-1AC 109 STAFF VESTIBULE 3'-0" 7'-0" 1 3/4" IHM B FF IN 3,5 IHM 1 PT3 7 109-1AC
109-2 109 STAFF VESTIBULE 3'-0" 7'-0" 1 3/4" WD B FF T HM 1 PT2 10 109-2
110-1 110 M.R.R. 3'-0" 7'-0" 1 3/4" WD A FF - HM 1 PT2 3 110-1
111-1 111 W.R.R. 3'-0" 7'-0" 1 3/4" WD A FF - HM 1 PT2 3 111-1
112-1 112 HALL 2'-0" 7'-0" 1 3/4" WD A FF - HM 1 PT2 2 112-1
113-1 113 MEP 4'-0" 7'-0" 1 3/4" IHM A FF - 3 IHM 5 PT2 5 113-1
114-1AC 114 BREAK AREA 3'-0" 7'-0" 1 3/4" IHM B FF IN 3 IHM 1 PT3 7 114-1AC
114-2 114 BREAK AREA 3'-0" 7'-0" 1 3/4" WD B FF T HM 1 PT2 3 114-2
115-1 115 JAN. 3'-0" 7'-0" 1 3/4" WD A FF - HM 1 PT2 2 115-1
116-1 116 WELLNESS 3'-0" 7'-0" 1 3/4" WD A FF - HM 1 PT2 4 116-1
117-1AC 117A IT STRG. 3'-0" 7'-0" 1 3/4" WD A FF - 3 HM 1 PT2 9 117-1AC
117-2AC 117 I.T./PACS ROOM 3'-0" 7'-0" 1 3/4" WD A FF - 3,4 HM 1 PT2 9 117-2AC
118-1 118 HUDDLE ROOM 3'-0" 7'-0" 1 3/4" WD B FF T HM 1 PT2 3 118-1
119-1 119 SMALL CONFERENCE ROOM 3'-0" 7'-0" 1 3/4" WD B FF T HM 1 PT2 3 119-1
120-1AC 120 STAFF VESTIBULE 3'-0" 7'-0" 1 3/4" IHM B FF IN 3,5 IHM 1 PT3 7 120-1AC
120-2 120 STAFF VESTIBULE 3'-0" 7'-0" 1 3/4" WD B FF T HM 1 PT2 10 120-2
121-1 121 HUDDLE ROOM 3'-0" 7'-0" 1 3/4" WD A FF - HM 3 PT2 1 121-1
122-1 122 FIRE SUITE 3'-0" 7'-0" 1 3/4" WD B FF T HM 1 PT2 10 122-1
122-2AC 122 FIRE SUITE 3'-0" 7'-0" 1 3/4" WD B FF T 3 HM 1 PT2 11 122-2AC
123-1 123 HUDDLE ROOM 3'-0" 7'-0" 1 3/4" WD A FF - HM 3 PT2 1 123-1
124-1 124 FOCUS ROOM 3'-0" 7'-0" 1 3/4" WD A FF - HM 3 PT2 1 124-1
125-1 125 FIRE READY ROOM 3'-0" 7'-0" 1 3/4" WD B FF T HM 4 PT2 10 125-1
125-2AC 125 FIRE READY ROOM 3'-0" 7'-0" 1 3/4" WD B FF T 3 HM 4 PT2 11 125-2AC
126-1AC 126 VESTIBULE 3'-0" 7'-0" 1 3/4" IHM B FF IN 3 IHM 1 PT 7 126-1AC
126-2AC 126 VESTIBULE 3'-0" 7'-0" 1 3/4" WD B FF T 2 HM 1 PT2 11 126-2AC
127-1AC 127 MAIL ROOM 3'-0" 7'-0" 1 3/4" WD A FF - 3 HM 1 PT2 9 127-1AC
128-1AC 128 OFFICE SUPPLY/PLOTTER ROOM 3'-0" 7'-0" 1 3/4" WD A FF - 3 HM 1 PT2 9 128-1AC
128-2AC 128 OFFICE SUPPLY/PLOTTER ROOM 3'-0" 7'-0" 1 3/4" WD A FF - 1 HM 1 PT2 9 128-2AC
129-1AC 129 RECEPTION 3'-0" 7'-0" 1 3/4" WD A FF - 3 HM 1 PT2 9 129-1AC
130-1 130 R.R. 3'-0" 7'-0" 1 3/4" WD A FF - HM 1 PT2 4 130-1
131-1 131 R.R. 3'-0" 7'-0" 1 3/4" WD A FF - HM 1 PT2 4 131-1
132-1AC 132 MAIN CONFERENCE ROOM FIELD OFFICE 3'-0" 7'-0" 1 3/4" WD B FF T 3 HM 4 PT2 11 132-1AC
132-2AC 132 MAIN CONFERENCE ROOM FIELD OFFICE 3'-0" 7'-0" 1 3/4" WD B FF T 3 HM 4 PT2 11 132-2AC jbeagle Text Box See Clarification 1.04 - Doors shall be prepped for access control, however, no PACS system will be installed under subject contract jbeagle Highlight
GRID
SEE A001 FOR
WALL ASSEMBLIES
SILL BEYOND
C
FOAM IN PLACE
INSULATION - FILL
CAVITY
2 1/2" COLD FORMED
METAL FRAMING
SHIM AS REQUIRED
NOTE: INSTALL LIQUID
FLASHING FOR OPENING
PER SHEATHING
MANUFACTURER WRITTEN
INSTRUCTIONS
JOINT SEALANT/
BACKING (EACH SIDE)
VINYL WINDOW
4"
GRID
C
6" COLD FORMED METAL
FRAMING, SEE THE
STRUCTURAL DRAWINGS
FOAM IN PLACE
INSULATION - FILL
CAVITY
2 1/2" COLD FORMED
METAL FRAMING
LIQUID FLASHING
INSTALL PER SHEATHING
MANUFACTURER WRITTEN
INSTRUCTIONS
CONTINUOUS PRE-
FINISHED SHEET
METAL AND TRIM
DRIP FLASHING
ALUMINUM FRAMED
ENTRANCES AND STOREFRONT
FRAME SYSTEM
GLASS UNIT
AS SCHEDULED
JOINT SEALANT/
BACKING EACH
SIDE
CONTINUOUS V-
GROOVE DRIP EDGE
(HEAD)
SEE A001 FOR
WALL ASSEMBLIES
SEE A601
B.O. FRAMING
SHIM AS REQUIRED
NOTE: INSTALL LIQUID
FLASHING FOR OPENING
PER SHEATHING
MANUFACTURER WRITTEN
INSTRUCTIONS
4"
2 1/2"
C
GRID
JAMB
BEYOND/BEHIND
SEE A001 FOR
WALL ASSEMBLIES
FOAM IN PLACE
INSULATION - FILL
CAVITY
6" COLD FORMED
METAL FRAMING
PRE-FINISHED METAL
SILL PAN FLASHING
WITH END DAMS AT
SILL
JOINT SEALANT
SEE A601
T.O. FRAMING
SHIM AS REQUIRED
JOINT SEALANT/
BACKING EACH SIDE
NOTE: INSTALL LIQUID
FLASHING FOR OPENING
PER SHEATHING
MANUFACTURER WRITTEN
INSTRUCTIONS
LIQUID FLASHING
INSTALL PER SHEATHING
MANUFACTURER WRITTEN
INSTRUCTIONS
4"
8"X4"X16" UNIT
MASONRY VENEER SILL
UNIT
GRID
VINYL WINDOW
PREFINISHED METAL SILL
PAN FLASHING WITH
END DAMS
5/8" GLASSMAT
GYPSUM SHEATHING
JOINT SEALANT
AND BACKING
FOAM IN PLACE INSULATION
SEE A601
T.O. FRAMING
MASONRY VENEER
SEE A001 FOR WALL
ASSEMBLIES
LIQUID FLASHING
INSTALL PER SHEATHING
MANUFACTURER WRITTEN
INSTRUCTIONS
FIRE TREATED WOOD
BLOCKING AS REQUIRED
NOTE: INSTALL LIQUID
FLASHING FOR OPENING
PER SHEATHING
MANUFACTURER WRITTEN
INSTRUCTIONS
SOLID SURFACE SILL - SEE
SPECIFICATION 123661.16
EXTEND SILL 1/2" PAST THE
OUTER EDGE OF THE WINDOW
OPENING.
2"
4"
D
JOINT SEALANT AND BACKING
2 1/2" COLD FORMED
METAL FRAMING
SHIM AS REQUIRED
D
GRID
SHIM AS REQUIRED
JOINT SEALANT/
BACKING (EACH SIDE)
SEE: A001 FOR
WALL ASSEMBLIES
FOAM IN PLACE
INSULATION -
FILL CAVITY
CMU VENEER
CORNER BLOCK NOTE: INSTALL LIQUID
FLASHING FOR OPENING
PER SHEATHING
MANUFACTURER WRITTEN
INSTRUCTIONS
2 1/2"
WINDOW AND FRAME
PER SCHEDULE
SET IN BED OF SEALANT
JOINT
SEALANT
SLOPE
FLASHING PAN
EXTERIOR CONCRETE,
SEE LANDSCAPE AND
CIVIL DRAWINGS
SEALANT OVER
EXPANSION
MATERIAL
SEE STRUCTURAL
DRAWINGS FOR
STRUCTURAL CONCRETE
WORK
VAPOR BARRIER BENEATH
CONCRETE SLAB - SEE
S002 FOR BARRIER
INFORMATION
1/2" EXPANSION JOINT,
SEE STRUCTURAL
DRAWINGS
GRID
C
6" COLD FORMED METAL
FRAMING, SEE THE
STRUCTURAL DRAWINGS
FOAM IN PLACE
INSULATION - FILL
CAVITY
2 1/2" COLD FORMED
METAL FRAMING
LIQUID FLASHING
INSTALL PER SHEATHING
MANUFACTURER WRITTEN
INSTRUCTIONS
CONTINUOUS PRE-
FINISHED SHEET
METAL AND TRIM
DRIP FLASHING
VINYL WINDOW
JOINT SEALANT/
BACKING
CONTINUOUS V-
GROOVE DRIP EDGE
(HEAD)
SEE A001 FOR
WALL ASSEMBLIES
SEE A601
B.O. FRAMING
NOTE: INSTALL LIQUID
FLASHING FOR OPENING
PER SHEATHING
MANUFACTURER WRITTEN
INSTRUCTIONS
4"
GRID
D
6" COLD FORMED METAL
FRAMING
FOAM IN PLACE
INSULATION - FILL CAVITY
2 1/2" COLD FORMED
METAL FRAMING
LIQUID FLASHING
INSTALL PER SHEATHING
MANUFACTURER WRITTEN
INSTRUCTIONS
CONTINUOUS PRE-
FINISHED SHEET METAL
AND TRIM DRIP
FLASHING
VINYL WINDOW
JOINT SEALANT/
BACKING
SEE A001 FOR
WALL ASSEMBLIES
SEE A601
B.O. FRAMING
SEALANT STRUCTURAL STEEL
LINTEL - SEE
STRUCTURAL DRAWINGS
NOTE: INSTALL LIQUID
FLASHING FOR OPENING
PER SHEATHING
MANUFACTURER WRITTEN
INSTRUCTIONS
WEEPS AT BOTTOM OF
MASONRY VENEER. SPACING
AT 24" O.C., SEE
SPECIFICATION 042000
CAVITY DRAINAGE MATERIAL
4"
D
GRID
SHIM AS REQUIRED
JOINT SEALANT/
BACKING (EACH SIDE)
SEE: A001 FOR
WALL ASSEMBLIES
FOAM IN PLACE
INSULATION - FILL
CAVITY
CMU VENEER
CORNER BLOCK
NOTE: INSTALL LIQUID
FLASHING FOR OPENING
PER SHEATHING
MANUFACTURER WRITTEN
INSTRUCTIONS
FIRE TREATED
BLOCKING AS
REQUIRED
P
LO
T
D A T E
P
LO
T T E D
B Y
C H K 'D
B Y
D E S
IG
N
O F F
IC
E
D E S
IG
N E D
B Y
P R O J E C T
N O
D R A W N
B Y
A P P R O V E D
B Y
U N
IT
E D
S T A T E S
D E P A R T M E N T
O F
T H E
IN
T E R
IO
R
B U R E A U
O F
L A N D
M A N A G E M E N T
D A T E
D E S C R
IP
T
IO
N
M A R K
A P P R O V E D
D A T E
SHEET OF
:4 :1
P M
C U s e rs a lf o n s o ra m ir e z D o c u m e n ts R e vi tL o c a lT e m p N W B L M D O a rc h a lf o n s o ra m ir e z .r vt
D O O R
A N D
W
IN
D O W
D E T A
IL
S
A602
N W B L M D O
S H O S H O N E
F
IE
L D
O F F
IC
E
R E P L A C E M E N T
J R C
R H
C U S H
IN
G
T E R R E L L
J R C
B L M
.1 .2
T W
IN
F A L L S
D
IS
T R
IC
T
ID
A H O
72 124
3" = 1'-0"A602
5 VINYL W INDOW JAMB DETAIL AT STUCCO
3" = 1'-0"A602
1 STOREFRONT W INDOW HEAD DETAIL AT STUCCO
3" = 1'-0"A602
8 VINYL W INDOW SILL AT STUCCO/CLERESTORY W INDOW S
3" = 1'-0"A602
9 VINYL W INDOW SILL AT CMU VENEER
3" = 1'-0"A602
4 STOREFRONT W INDOW JAMB AT CMU VENEER
3" = 1'-0"A602
7 TYPICAL STOREFRONT FRAMING SILL AT SIDEW ALK
3" = 1'-0"A602
2 VINYL W INDOW HEAD DETAIL AT STUCCO
3" = 1'-0"A602
3 VINYL W INDOW HEAD DETAIL AT CMU VENEER
3" = 1'-0"A602
6 VINYL W…
This is the start of the file's text. The full file is on GovTribe.