B08_Attachment_1D_Shoshone_Drawings_59-111.pdf

PDF 16 MB Posted

Attached to
Shoshone Wildland Fire Operations and Field Office
Solicitation number
140L0625R0002
Issued by

View the file

Other files

File Type Posted
Sol_140L0625R0002_Amd_0008.pdf PDF
B08_Attachment_19_Revised_Final_Specifications_8-7-25_0007.pdf PDF
B08_Attachment_20C_Revised_Final_Drawings_20250804_Part3_0007.pdf PDF
B08_Attachment_20D_Revised_Final_Drawings_20250804_Part4_0007.pdf PDF
B08_Attachment_20A_Revised_Final_Drawings_20250804_Part1_0007.pdf PDF
B08_Attachment_20E_Revised_Final_Drawings_20250804_Part5_0007.pdf PDF
B08_Attachment_20B_Revised_Final_Drawings_20250804_Part2_0007.pdf PDF
Sol_140L0625R0002_Amd_0007.pdf PDF
B08_Attachment_18_Q_A_4_25R0002_0007.pdf PDF
Sol_140L0625R0002_Amd_0006.pdf PDF
B08_Attachment_17_J_A_140L0625R0002_0005.pdf PDF
Sol_140L0625R0002_Amd_0005.pdf PDF
B08_Attachment_16_Q_A_3__25R0002_0004.pdf PDF
Sol_140L0625R0002_Amd_0004.pdf PDF
Sol_140L0625R0002_Amd_0003.pdf PDF
B08_Attachment_15_Past_Perf_Questionnaire_UPDATED_0002.docx DOCX document
B08_Attachment_14_Q_A_2__25R0002_0002.docx DOCX document
Sol_140L0625R0002_Amd_0002.pdf PDF
B08_Attachment_12_Q_A_1_0001.pdf PDF
B08_Attachment_13_Site_Visit_Sign-In_Sheet_0001.pdf PDF
Sol_140L0625R0002_Amd_0001.pdf PDF
B08_Attachment_3_Price_Breakout.xlsx XLSX spreadsheet
B08_Attachment_1B_Shoshone_Drawings_8-14.pdf PDF
B08_Attachment_2B_Revised_Specs_012000_Nov2024.pdf PDF
B08_Attachment_9_Wage_Determination.pdf PDF
B08_Attachment_8_Limitations_on_SubK_Breakout.xlsx XLSX spreadsheet
B08_Attachment_1C_Shoshone_Drawings_15-58.pdf PDF
B08_Attachment_1E_Shoshone_Drawings_112-124.pdf PDF
Sol_140L0625R0002.pdf PDF
B08_Attachment_1A_Shoshone_Drawings_1-7.pdf PDF
B08_Attachment_4_Geotech_Report.pdf PDF
B08_Attachment_7_ACM_Report.pdf PDF
B08_Attachment_5_Clarifications.pdf PDF
B08_Attachment_6_Idaho_Lead-Based_Paint_Debris_Fact_Sheet.pdf PDF
B08_Attachment_11_SF1442_Completion_Instructions.pdf PDF
B08_Attachment_10_Past_Perf_Questionnaire.docx DOCX document
B08_Attachment_2A_Specifications.pdf PDF
Show all 37

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REF REF

REF

ASSEMBLY TYPE (SEE ASSEMBLIES SHEET)

ASSEMBLY MODIFIER, PER TYPE

ROOM NAME AND NUMBER

WINDOW TYPE (SEE A600s)

KEYNOTE

DRAWING NUMBER

SHEET WHERE DRAWN

DOOR NUMBER (SEE SHEET A601)

DIMENSION TO FACE OF FRAMING

DIMENSION TO GRID LINE

A101

SIM

X

XX

NAME

X

X

PLAN LEGEND

DIRECTION OF VIEW, IF APPLICABLE

DIMENSION TO CENTER LINE

CL

FIRE EXTINGUISHER CABINET AND

EXTINGUISHER - SEE SPECIFICATIONSFEC

A201

A2012

A201

A201

A301

A301

A301

______________2

A301

I.T./PACS

ROOM

HUDDLE

ROOM

WELLNESS

HALL

PRIVATE

OFFICE

HUDDLE

ROOM

PRIVATE

OFFICE

HUDDLE

ROOM

FIRE READY

ROOM

HUDDLE

ROOM

FOCUS

ROOM

FIRE SUITE

MEP

BREAK

AREA

SMALL

CONFERENCE

ROOM

FIELD

OFFICE/S.S./DISTRICT

STAFF

JAN.

STAFF

VESTIBULE

STAFF

VESTIBULE

MAIL ROOM

A702

A701

A702

A C

110-1111-1

125-1

A C

122-1

106-1

107-1121-1

123-1

124-1

A C

A C

VE

VE

VE

VE

VA

VD VE VE VE VE

VE

VE

VE

VE

VE

VE

VE

VE

VE VE VE

VA VA

VE

ENTRY HALL

MAIN

CONFERENCE

ROOM FIELD

OFFICE

LOBBY/ENTRY

RECEPTION

OFFICE

SUPPLY/PLOTTER

ROOM

A C

A C

A C

A C

126-2AC126-1AC

VAVAVB

H128-2AC

VE VE VE VE

VE

VE

VE

SMALL

CONFERENCE

ROOM

W.R.R.

VE

VA

VESTIBULE

A C

105-1

VE VE VE

A701

A701

A301

ALB

C

D D

C

C

C

D

D

D

C

C

D

B

B

B

A

A

B B

A

A

B

E

A

A

A

B

A

B

A

A

A 1 B

A

D

A

D

D

A.1

B

A

E

B

A

A

E

A A

A

B 1,3

B

A

A

B 1,3

A

B

B B.1

AA

A

B.1

B

E

R.R.

R.R.

B

A.1

42' - 6"

42' - 8"

40' - 8" 42' - 4" 43' - 0" 47' - 8"

90' - 4" 40' - 8"

6'

5'

7'

C L C L

C L C L

C L 5'

4"

8'

7'

8'

CLCLCLCL

7' - 3" 8' - 0" 12' - 0" 8' - 0"

CLCLCLCLCL

8' - 0" 8' - 0" 8' - 0" 8' - 0" 4' - 5"

CLCLCLCL5' - 6" 8' - 0" 8' - 0" 8' - 0"

CLCLCLCLCLCL 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 3' - 3"

C L C L

C L C L

C L C L

C L C L

7'

8'

8'

8'

8'

8'

8'

2"

9' - 10"

CL

EA

R

6'

5' - 6" 11' - 7" 5' - 8" 5' - 11 1/2" 12' - 0"

2'

0"

9'

1"

12' - 5 27/32"

6' - 0"

6' - 0"

11' - 10" 21' - 0"

103-1

3' - 0"

B

M.R.R.

B

B

127-1AC

1 5 6 8 9 11 13 14 15 16 17 18 19

A

B

C

2 3 4 7 10

D D

IT STRG.

117A

A C

A.1

A.1A.1

A

A

AFEC

FEC

FEC

A111

9' - 4" 3' - 4" 5' - 4" 4' - 0" 5' - 4" 3' - 4"3' - 4"4' - 0"3' - 4"4' - 0" 11' - 4" 4' - 8" 6' - 8" 3' - 4" 12' - 0" 4' - 0"

A111

A111

BELOW AT

COLUMN BASE

AT COLUMN

CAP

42' - 8" 2' - 4" 11' - 9" 3' - 8" 17' - 9" 9' - 10 1/2" 7' - 8" 13' - 5" 4' - 4" 10' - 9" 7' - 0" 22' - 6" 18' - 2"

0"

13' - 6" 13' - 6" 13' - 8" 13' - 9" 14' - 2" 14' - 5" 88' - 10 1/2"

B.1

B 1,3

B

B

B

B

E

E

A

4' - 0" 8' - 0" 4' - 0"

2' - 8"

2' - 8"4' - 0" 8' - 0" 4' - 0" D

2'

4'

VFVFVFVF

VF

A

FEC

104-1AC

A

B

A

A

A.1

FIELD

OFFICE/S.S./DISTRICT

STAFF

A

A

8' - 1"

3'

A. SEE CIVIL, STRUCTURAL, MECHANICAL, AND ELECTRICAL

DRAWINGS FOR ADDITIONAL REQUIREMENTS AND

COORDINATION.

B. SEE FIRE DRAWINGS FOR ADDITIONAL WORK TO OCCUR AND

ADDITIONAL REQUIREMENTS.

C. SEE A001 AND A101 FOR WALL TYPE INFORMATION AND

LOCATIONS.

D. SEE CODE PLAN FOR INFORMATION ON SQUARE FOOTAGE OF

BUILDING AND OTHER RELATED ITEMS.

E. SEE CODE PLAN FOR ENVELOPE ENERGY REQUIREMENTS.

F. SEE SPECIFICATIONS FOR ALL BUILDING COMPONENTS.

G. SEE EXTERIOR ELEVATIONS ON A201 FOR LOCATIONS OF CMU

VENEER AT BASE OF EXTERIOR WALLS.

H. COORDINATE EXTERIOR WALL DIMENSIONS AND FACE OF STEM

WALL LOCATIONS WITH STRUCTURAL DRAWINGS.

I. DIMENSIONS OF WINDOWS LOCATED WITHIN STUCCO ARE TO

CENTERLINE OF WINDOW. DIMENSIONS TO WINDOWS AND

FRAMES LOCATED WITHIN CMU VEENER ARE TO OUTSIDE OF

ROUGH OPENING.

J. SEE FINISH PLAN ON A501 FOR COORDINATION OF FINISHES

AND OTHER ITEMS MOUNTED ON INTERIOR WALLS.

K. SEE A501 FOR ROLLER SHADE LOCATIONS.

L. PROVIDE METAL STUD BLOCKING IN WALL AS NEEDED FOR

ALL MOUNTED EQUIPMENT, MILLWORK, AND HARDWARE,

COORDINATE WITH WALL TYPES.

GENERAL NOTES

P

LO

T

D A T E

P

LO

T T E D

B Y

C H K 'D

B Y

D E S

IG

N

O F F

IC

E

D E S

IG

N E D

B Y

P R O J E C T

N O

D R A W N

B Y

A P P R O V E D

B Y

U N

IT

E D

S T A T E S

D E P A R T M E N T

O F

T H E

IN

T E R

IO

R

B U R E A U

O F

L A N D

M A N A G E M E N T

D A T E

D E S C R

IP

T

IO

N

M A R K

A P P R O V E D

D A T E

SHEET OF

:3 :3

P M

C U s e rs a lf o n s o ra m ir e z D o c u m e n ts R e vi tL o c a lT e m p N W B L M D O a rc h a lf o n s o ra m ir e z .r vt

F L O O R

P L A N

A101

N W B L M D O

S H O S H O N E

F

IE

L D

O F F

IC

E

R E P L A C E M E N T

J R C

R H

C U S H

IN

G

T E R R E L L

J R C

B L M

.1 .2

T W

IN

F A L L S

D

IS

T R

IC

T

ID

A H O

59 124

# SHEET NOTES

1 OPERABLE PARTITION DOOR. SEE SPECIFICATIONS.

STRUCTURAL SUPPORTS NECESSARY, SEE STRUCTURAL

DRAWINGS FOR STRUCTURAL STEEL ASSOCIATED WITH DOOR.

2 MECHANICAL EQUIPMENT, SEE MECHANICAL DRAWINGS.

3 FIRE SPRINKLER RISER, SEE FIRE DRAWINGS.

4 PLUMBING ACCESS AREA. SEE PLUMBING DRAWINGS FOR

PIPING LOCATIONS.

5 PRINTER BY GOVERNMENT, NOT IN CONTRACT.

A101

1 FLOOR PLAN

NORTH REF

SCALE IN FEET

A.1

A

A.1

PARTITION MANUFACTURER SELECTED

COORDINATE SIZE WITH OPERABLE

PA

RT

IT

IO

N M

AN

U

FA

CT

UR

ER

S

EL

EC

TE

D

CO

O

RD

IN

AT

E

SI

ZE

W

IT

H O

PE

RA

BL

E

STRUCTURAL STEEL COLUMN ASSOCIATED

WITH OPERABLE PARTITION, SEE

STRUCTURAL DRAWINGS.

OPERABLE PARTITION - SEE

SPECIFICATION 102239 FOR FURTHER

INFORMATION

5"

5"

2' - 9"

2'

SEALANT

TYP.

1/2"1

A311

S L O P E

SLOPE SLOPE

S L O P E

CL

CL

4"X8"X16" CMU BLOCK

FULLY GROUTED, RUNNING

BOND, BLOCK COLOR TO

MATCH BUILDING BLOCK

COLOR, SEE STRUCTURAL

DRAWING FOR FURTHER

DETAILS

STRUCTURAL STEEL

COLUMN

CL

CL

P

LO

T

D A T E

P

LO

T T E D

B Y

C H K 'D

B Y

D E S

IG

N

O F F

IC

E

D E S

IG

N E D

B Y

P R O J E C T

N O

D R A W N

B Y

A P P R O V E D

B Y

U N

IT

E D

S T A T E S

D E P A R T M E N T

O F

T H E

IN

T E R

IO

R

B U R E A U

O F

L A N D

M A N A G E M E N T

D A T E

D E S C R

IP

T

IO

N

M A R K

A P P R O V E D

D A T E

SHEET OF

:3 :3

P M

C U s e rs a lf o n s o ra m ir e z D o c u m e n ts R e vi tL o c a lT e m p N W B L M D O a rc h a lf o n s o ra m ir e z .r vt

P L A N

D E T A

IL

S

A111

N W B L M D O

S H O S H O N E

F

IE

L D

O F F

IC

E

R E P L A C E M E N T

J R C

R H

C U S H

IN

G

T E R R E L L

J R C

B L M

.1 .2

T W

IN

F A L L S

D

IS

T R

IC

T

ID

A H O

60 124

A111

3 FOLDING PARTITION POCKET

SCALE IN FEET

A111

2 TYPICAL COLUMN W RAP AT CONCRETE CAP

SCALE IN FEET

A111

1 TYPICAL COLUMN W RAP AT BASE

A201

A2012

A201

A201

A301

A301

A301

______________2

A301

B E L O W

A B O V E

VCVCVCVCVCVCVCVCVCVCVCVC

A301

8'

2' - 0"

2'

2' - 0"

2' - 0"

2'

2' - 0"

2'

2' - 0"

2'

2' - 0"

2'

3 3 3 3 3 3 333333

2' - 0"

2' - 0"

1 5 6 8 9 11 13 14 15 16 17 18 19

AA

BB

C

2 3 4 7 10

D D

5 5

1'

3'

4"

1'

CLCLCLCLCLCLCLCLCLCLCLCL

8' - 0" 8' - 0" 11' - 0" 8' - 0" 25' - 6" 8' - 0" 8' - 0" 8' - 0" 51' - 0" 8' - 0" 8' - 0" 8' - 0"

A122

A122

A122

A122

A122

______________5

A122

A122

A122

A122

A122

A122

A122

A122

A122

45' - 6"

3'

CL

E.Q. E.Q.

6' - 0"

TYP. OF 4

6 6

A122

A122

1. THE FOLLOWING REFERENCES HAVE BEEN USED AS A BASIS

FOR DESIGN OF THE ROOFING RELATED WORK OF THE PROJECT

AND SHALL BE USED BY THE CONTRACTOR TO DETERMINE

REQUIREMENTS FOR FABRICATION AND/OR INSTALLATION WHEN

NOT SPECIFICALLY INDICATED IN THE CONTRACT DOCUMENTS.

A.NATIONAL ROOFING CONTRACTORS ASSOCIATION (NRCA)

"ROOFING AND WATER PROOFING MANUAL, FIFTH EDITION".

B. SHEET METAL AND AIR CONDITIONING NATIONAL

CONTRACTORS ASSOCIATION (SMACNA) - "ARCHITECTURAL

SHEET METAL MANUAL, FIFTH EDITION".

C. INTERNATIONAL BUILDING CODE: MOST CURRENT

ADOPTED VERSION

D. INTERNATIONAL PLUMBING CODE: MOST CURRENT

ADOPTED VERSION

E. AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE) -

ASCE/SEI 7-10: "MINIMUM DESIGN LOADS FOR BUILDINGS

AND OTHER STRUCTURES" (REVISION OF ASCE/SEI 7-05).

F. MATERIAL MANUFACTURERS MOST RECENT PRINTED

SPECIFICATIONS AND INSTALLATION DETAILS.

2. PRIOR TO THE START OF WORK THE CONTRACTOR SHALL

PROVIDE AND INSTALL PROTECTION OVER, UNDER AND/OR

AROUND ALL SERVICE LINES, BUILDING COMPONENTS,

SIDEWALKS, PAVEMENT AND LANDSCAPING WHICH COULD BE

DAMAGED OR SOILED WHILE PERFORMING WORK OF THE

CONTRACT.

3. DETAILS IN THE PROJECT DRAWINGS ARE SHOWN AT

SPECIFIC LOCATIONS AND ARE INTENDED TO SHOW GENERAL

REQUIREMENTS THROUGHOUT:

A. DETAILS NOTED ARE "TYPICAL" AND IMPLY ALL SIMILAR

CONDITIONS TREATED SIMILARLY. MODIFICATIONS TO BE

MADE BY THE CONTRACTOR TO ACCOMMODATE MINOR

VARIATIONS WITHOUT ADDITIONAL COST TO THE GOVERNMENT.

GENERAL ROOFING NOTES

MATERIALS LEGEND

STANDING SEAM METAL ROOF PANEL PER

SPECIFICATION 074113.16- ROOF ASSEMBLY

'H1' - SEE ASSEMBLY DETAILS SHEET

P

LO

T

D A T E

P

LO

T T E D

B Y

C H K 'D

B Y

D E S

IG

N

O F F

IC

E

D E S

IG

N E D

B Y

P R O J E C T

N O

D R A W N

B Y

A P P R O V E D

B Y

U N

IT

E D

S T A T E S

D E P A R T M E N T

O F

T H E

IN

T E R

IO

R

B U R E A U

O F

L A N D

M A N A G E M E N T

D A T E

D E S C R

IP

T

IO

N

M A R K

A P P R O V E D

D A T E

SHEET OF

:3 :4

P M

C U s e rs a lf o n s o ra m ir e z D o c u m e n ts R e vi tL o c a lT e m p N W B L M D O a rc h a lf o n s o ra m ir e z .r vt

R O O F

P L A N

A121

N W B L M D O

S H O S H O N E

F

IE

L D

O F F

IC

E

R E P L A C E M E N T

J R C

R H

C U S H

IN

G

T E R R E L L

J R C

B L M

.1 .2

T W

IN

F A L L S

D

IS

T R

IC

T

ID

A H O

61 124

NORTH REF

SCALE IN FEET

A121

1 ROOF PLAN

# SHEET NOTES

1 GUTTER AND DOWNSPOUTS, SEE EXTERIOR ELEVATIONS FOR

DOWNSPOUT LOCATIONS.

2 LINE OF FACE OF EXTERIOR STUD BELOW.

3 WINDOW AT FACADE BELOW. SEE A201 AND A601 FOR

FURTHER INFORMATION.

4 MECHANICAL VENT PENETRATIONS, SEE MECHANICAL

DRAWINGS. REFER TO 1/A124 AND 2/A124 FOR

ADDITIONAL INFORMATION.

5 TUBULAR DAYLIGHTING DEVICE UNIT SKYLIGHT, SEE

SPECIFICATIONS AND ROOF DETAILS SHEET FOR FURTHER

INFORMATION. SEE CEILING PLAN FOR DAYLIGHT TUBE

DIFFUSER LOCATIONS. REFER TO 4/A124 AND 5/A124 FOR

ADDITIONAL INFORMATION.

6 ONE ROW OF SNOW FENCE REQUIRED WITH ASSOCIATED

SEAM CLAMPS. START CLAMPS 1'-0" FROM THE EAVE.

SPACE CLAMPS 16" O.C. (AT SEAMS). INSTALL SNOW CLIP

ONTO ASSOCIATED BAR BETWEEN EVERY PAIR OF SEAMS.

SEE SPECIFICATIONS FOR FURTHER INFORMATION.

7 PLUMBING VENT

TOP OF W ALL

113'-0"

C

SEALANT

FIRE TREATED WOOD NAILERS

PREFINISHED BREAK METAL FASCIA FLASHING,

BREAK INTO TWO SEPARATE PIECES

2x12 TREATED WOOD BLOCKING

SEALANT

CONTINUOUS CLEAT

PREFINISHED METAL COPING

STRUCTURAL FRAMING, SEE

STRUCTURAL DRAWINGS

SECURE @ 12" O.C. USING HEX HEAD,

GASKETED #12 GALVANIZED STEEL

THREADED FASTENERS

LAP TEMPORARY ROOF AND VAPOR

RETARDER DOWN OVER BLOCKING

2x8 TREATED WOOD BLOCKING

METAL SOFFIT PANEL

FOAM IN PLACE INSULATION -

COVER FIRST DECK FLUTE

FOR DIMENSIONS

SEE ROOF PLAN

STRUCTURAL FRAMING, SEE

STRUCTURAL DRAWINGS

DRIP EDGE

EDGE ANGLE, SEE STRUCTURAL DRAWINGS

WEATHER BARRIER, SEAL TO DECK

VAPOR RETARDER, SEAL TO DECK

SEALANT

FIRE TREATED WOOD NAILERS

PREFINISHED BREAK METAL

FASCIA FLASHING, BREAK INTO

TWO SEPARATE PIECES

2x12 TREATED WOOD BLOCKING

SEALANT

CONTINUOUS CLEAT

PREFINISHED METAL COPING

STRUCTURAL STEEL HSS -

SEE STRUCTURAL DRAWINGS

SECURE @ 12" O.C. USING HEX

HEAD,

GASKETED #12 GALVANIZED STEEL

THREADED FASTENERS

LAP TEMPORARY ROOF AND VAPOR

RETARDER DOWN OVER BLOCKING

2x8 TREATED WOOD BLOCKING

METAL SOFFIT PANEL

FOAM IN PLACE INSULATION -

COVER FIRST DECK FLUTE

STRUCTURAL FRAMING, SEE

STRUCTURAL DRAWINGS

FLOATING RAKE SUPPORT WITH

NECESSARY FASTENERS

H1

C

EDGE ANGLE, SEE

STRUCTURAL DRAWINGS

WEATHER BARRIER, SEAL TO DECK

VAPOR RETARDER, SEAL TO DECK

B

SEALANT

FIRE TREATED WOOD NAILERS

PREFINISHED BREAK METAL

FASCIA FLASHING, BREAK INTO

TWO SEPARATE PIECES

2x12 TREATED WOOD BLOCKING

SEALANT

CONTINUOUS CLEAT

PREFINISHED METAL COPING

2 1/2" COLD FORMED FRAMING

SECURE @ 12" O.C. USING HEX HEAD,

GASKETED #12 GALVANIZED STEEL

THREADED FASTENERS

LAP TEMPORARY ROOF AND VAPOR

RETARDER DOWN OVER BLOCKING

2x8 TREATED WOOD BLOCKING

METAL SOFFIT PANEL

FOAM IN PLACE INSULATION -

COVER FIRST DECK FLUTE

STRUCTURAL FRAMING, SEE

STRUCTURAL DRAWINGS

C

2 1/2" COLD FORMED FRAMING

FOAM IN PLACE INSULATION -

FILL CAVITY

BATT INSULATION

3" / 1'-0"

DRIP EDGE

H1

EDGE ANGLE, SEE STRUCTURAL DRAWINGS

WEATHER BARRIER, SEAL TO DECK

VAPOR RETARDER, SEAL TO DECK

SLIP TRACK TO BE FRAMED ALONG

ENTIRE LENGTH OF STRUCTURAL

FRAMING, SEE STRUCTURAL DRAWINGS.

BATT INSULATION

B

H1

EXTERIOR

INTERIOR

INTERIOR

PRE-FINISHED METAL FLASHING

FASTENER, TYP.

PRE-FINISHED METAL COUNTERFLASHING

PRE-FINISHED METAL REGLET

FLASHING

RUN METAL FLASHINGS BEHIND

INSULATION

LAP SELF ADHERING VAPOR

RETARDER UP SHEATHING

LAP BUILDING WRAP FLASHING OVER

METAL FLASHINGS

CLIP AND BEARING PLATE

FOR STANDING SEAM

METAL ROOF

C

STRUCTURAL FRAMING, SEE

STRUCTURAL DRAWINGS

2 1/2" COLD FORMED

FRAMING

BATT INSULATION

M

IN

8"

FIRE TREATED WOOD NAILERS

2x12 TREATED WOOD BLOCKING

LAP TEMPORARY ROOF AND VAPOR

RETARDER DOWN OVER BLOCKING

2x8 TREATED WOOD BLOCKING

METAL SOFFIT PANEL

STRUCTURAL FRAMING, SEE

STRUCTURAL DRAWINGS

DRIP EDGE

HOOK PANEL OVER DRIP

EDGE - REFER TO NOTE #1

STYLE D DRIP EDGE

W/CONTINUOUS CLEAT

SELF ADHERING MEMBRANE -

LAP S.A.M. ONTO FASCIA

PRE-FINISHED METAL FLASHING WITH

DRIP EDGE - COLOR TO MATCH METAL

PANEL ROOFING - WRAP BREAK METAL

SEPARATE INTO TWO PIECES TO PREVENT

OIL CANNING, NO EXPOSED FASTENERS.

WITH CONTINIOUS CLEAT.

SEE GUTTER DETAIL ON A123

FOR FURTHER INFORMATION

AND DIMENSIONS M

IN

1/

2"

EDGE ANGLE, SEE

STRUCTURAL DRAWINGS

H1

SEALANT

FIRE TREATED WOOD NAILERS

PREFINISHED BREAK METAL

FASCIA FLASHING, BREAK INTO

TWO SEPARATE PIECES

2x12 TREATED WOOD BLOCKING

SEALANT

CONTINUOUS CLEAT

PREFINISHED METAL COPING

STRUCTURAL STEEL HSS -

SEE STRUCTURAL DRAWINGS

SECURE @ 12" O.C. USING HEX

HEAD,

GASKETED #12 GALVANIZED STEEL

THREADED FASTENERS

LAP TEMPORARY ROOF AND VAPOR

RETARDER DOWN OVER BLOCKING

2x8 TREATED WOOD BLOCKING

METAL SOFFIT PANEL

FOAM IN PLACE INSULATION

STRUCTURAL FRAMING, SEE

STRUCTURAL DRAWINGS

FLOATING RAKE SUPPORT WITH

NECESSARY FASTENERS

H1

EDGE ANGLE, SEE

STRUCTURAL DRAWINGS

WEATHER BARRIER, SEAL TO DECK

VAPOR RETARDER, SEAL TO DECK

P

LO

T

D A T E

P

LO

T T E D

B Y

C H K 'D

B Y

D E S

IG

N

O F F

IC

E

D E S

IG

N E D

B Y

P R O J E C T

N O

D R A W N

B Y

A P P R O V E D

B Y

U N

IT

E D

S T A T E S

D E P A R T M E N T

O F

T H E

IN

T E R

IO

R

B U R E A U

O F

L A N D

M A N A G E M E N T

D A T E

D E S C R

IP

T

IO

N

M A R K

A P P R O V E D

D A T E

SHEET OF

:3 :4

P M

C U s e rs a lf o n s o ra m ir e z D o c u m e n ts R e vi tL o c a lT e m p N W B L M D O a rc h a lf o n s o ra m ir e z .r vt

R O O F

D E T A

IL

S

A122

N W B L M D O

S H O S H O N E

F

IE

L D

O F F

IC

E

R E P L A C E M E N T

J R C

R H

C U S H

IN

G

T E R R E L L

J R C

B L M

.1 .2

T W

IN

F A L L S

D

IS

T R

IC

T

ID

A H O

62 124

A122

3 TYPICAL LOW SIDE EAVE DETAIL AT DRIP EDGE

SCALE IN FEET

A122

6 TYPICAL RAKE DETAIL AT STUCCO

SCALE IN FEET

A122

2 TYPICAL HIGH EAVE DETAIL

SCALE IN FEET

SCALE IN FEET

A122

1 TYPICAL ROOF TO W ALL TRANSITION

SCALE IN FEET

A122

4 LOW EAVE DETAIL W ITH GUTTER

10.50

SCALE IN FEET

A122

5 TYPICAL RAKE DETAIL AT CMU VENEER

5"

5"

GUTTER - PRE FINISHED

24 GA GALV STEEL

GUTTER STRAP -

PRE FINISHED 24 GA

GALV STEEL 1" WIDE

AT 24" O.C.

RIVETS AT 1" O.C. ALL SIDES -

COLOR TO MATCH METAL

FULL BED OF NON CURING

SEALANT IN JOINT - TYP ALL AROUND

DROP TUBE

PRE FINISHED 24 GA GALV

STEEL DOWNSPOUT (4"x4")

3"

HEX HEAD STAINLESS STEEL

THREADED FASTENER HEAD -

COLOR TO MATCH METAL

STRAP AND DROP TUBE

GUTTER DIMENSIONS

GUTTER GUARD

SMACNA GUTTER PROFILE 'B'

RE: ROOF PLAN FOR GUTTER LOCATIONS.

RE: EXTERIOR ELEVATIONS FOR DOWNSPOUT LOCATIONS.

B

H1

EXTERIOR

INTERIOR

INTERIOR

FASTENER, TYP.

PRE-FINISHED METAL

COUNTERFLASHING

PRE-FINISHED METAL REGLET

FLASHING

RUN METAL FLASHINGS BEHIND

INSULATION

LAP SELF ADHERING VAPOR

RETARDER UP SHEATHING

CLIP AND BEARING PLATE

FOR STANDING SEAM

METAL ROOF

STRUCTURAL FRAMING, SEE

STRUCTURAL DRAWINGS

J-MOLD FOR GYPSUM

BOARD

JAMB BEYOND/BEHIND

FOAM IN PLACE

INSULATION - FILL CAVITY

6" COLD FORMED METAL

FRAMING, SEE STRUCTURAL

DRAWINGS

PRE-FINISHED METAL SILL

PAN FLASHING WITH END

DAMS AT SILL

JOINT SEALANT

SHIM AS REQUIRED

JOINT SEALANT/

BACKING EACH SIDE

A602

M

IN

8"

SEALANT

STRUCTURAL

FRAMING, SEE

STRUCTURAL

DRAWINGS

METAL SOFFIT PANEL

FOAM IN PLACE INSULATION -

COVER FIRST DECK FLUTE

STRUCTURAL FRAMING,

SEE STRUCTURAL

DRAWINGS

WEATHER BARRIER,

SEAL TO DECK

C

H1

TOP OF W ALL

113'-0"

D

SEALANT

2 1/2" COLD FORMED FRAMING

METAL SOFFIT PANEL

FOAM IN PLACE

INSULATION - COVER

FIRST DECK FLUTE

STRUCTURAL FRAMING, SEE

STRUCTURAL DRAWINGS

WEATHER BARRIER, SEAL TO DECK

H1

D

FIRE TREATED WOOD NAILERS

PREFINISHED BREAK METAL FASCIA

FLASHING, BREAK INTO TWO

SEPARATE PIECES

2x12 TREATED WOOD BLOCKING

SEALANT

CONTINUOUS CLEAT

PREFINISHED METAL COPING

SECURE @ 12" O.C. USING HEX HEAD,

GASKETED #12 GALVANIZED STEEL

THREADED FASTENERS

LAP TEMPORARY ROOF AND VAPOR

RETARDER DOWN OVER BLOCKING

2x8 TREATED WOOD BLOCKING

DRIP EDGE

EDGE ANGLE, SEE

STRUCTURAL DRAWINGS

FOR DIMENSIONS

SEE ROOF PLAN

TOP OF W ALL

113'-0"

SEALANT

STRUCTURAL FRAMING,

SEE STRUCTURAL

METAL SOFFIT PANEL

FOAM IN PLACE

INSULATION - COVER

FIRST DECK FLUTE

WEATHER BARRIER,

SEAL TO DECK

P

LO

T

D A T E

P

LO

T T E D

B Y

C H K 'D

B Y

D E S

IG

N

O F F

IC

E

D E S

IG

N E D

B Y

P R O J E C T

N O

D R A W N

B Y

A P P R O V E D

B Y

U N

IT

E D

S T A T E S

D E P A R T M E N T

O F

T H E

IN

T E R

IO

R

B U R E A U

O F

L A N D

M A N A G E M E N T

D A T E

D E S C R

IP

T

IO

N

M A R K

A P P R O V E D

D A T E

SHEET OF

:3 :5

P M

C U s e rs a lf o n s o ra m ir e z D o c u m e n ts R e vi tL o c a lT e m p N W B L M D O a rc h a lf o n s o ra m ir e z .r vt

R O O F

D E T A

IL

S

A123

N W B L M D O

S H O S H O N E

F

IE

L D

O F F

IC

E

R E P L A C E M E N T

J R C

R H

C U S H

IN

G

T E R R E L L

J R C

B L M

.1 .2

T W

IN

F A L L S

D

IS

T R

IC

T

ID

A H O

63 124

A123

4 GUTTER DIMENSIONS / STRAP AND DROP TUBE

A123

1 ROOF TO W ALL TO W INDOW TRANSITION

SCALE IN FEET

SCALE IN FEET

A123

2 TYPICAL W ALL TO ROOF TRANSITION AT TYPE C W ALL

SCALE IN FEET

A123

3 TYPICAL W ALL TO ROOF TRANSITION AT TYPE D W ALL AND EAVE DETAIL

SCALE IN FEET

A123

5 TYPICAL W ALL TO ROOF TRANSITION AT TYPE D W ALL

DIFFUSER

FRAME

CEILING TILE

SQUARE/ROUND

TRANSITION V-

CLIP

T-BAR

SQUARE/ROUND

TRANSITION

A

A

METAL DECK

EXTENSION TUBE - COORDINATE

ROUTING TO CEILING BELOW WITH

MECHANICAL, PLUMBING,

STRUCTURAL AND FIRE SYSTEM

NOTE:

-ALL TUBE JOINTS AND SEAMS TAPED WITH 2" FOIL TAPE

-MIN. ROOF SLOPE IS 2.4 DEGREES

-6" MIN. CLEARANCE SHOULD BE MAINTAINED FROM ALL

COMPONENTSSECTION VIEW

STRUCTURAL FRAMING, SEE

STRUCTURAL DRAWINGS

METAL FLASHING BY TUBULAR DAYLIGHTING

DEVICE MANUFACTURER. SEE SPECIFICATION

086200 AND DETAIL SEE 5/A124

PRE-MOLDED PIPE FLASHING

W/ALUMINUM BASE SET IN CONT.

BEAD OF URETHANE SEALANT

GASKETED FASTENER - INSTALL

PER MANF. RECOMMENDATIONS

AND INSTRUCTIONS

CONTINUOUS BEAD

URETHANE SEALANT

STAINLESS STEEL

CLAMPING RING

UNDER NO CIRCUMSTANCES CAN THE

PIPE PENETRATE OR COME WITHIN 4"

OF THE STANDING SEAM METAL PANEL

ROOF PANEL SEAM

NOTES: APPLY LAP SEALANT

BETWEEN PENETRATION AND

PRE-MOLDED PIPE FLASHING

PRIOR TO INSTALLATION OF

CLAMPING RING.

PIPE SHOULD EXTEND 1'-0"

MINIMUM ABOVE ROOF SURFACE

SEE SHEETS A121, A122, P401

AND PLUMBING DRAWINGS FOR

PENETRATION LOCATIONS

H1

NOTE: USE METAL JACK

SLEEVES AT ALL 'HOT' PIPE

PENETRATION LOCATIONS

H1

M

IN

CURB PAN

S-CLIP

SET S-CLIP IN 3/4" BUTYL TAPE

EXHAUST/INTAKE VENT CURB -

REMOVE /REINSTALL AS REQUIRED

TO INSTALL FLASHING (TYPICAL)

PREMANUFACTURED CURB

VENT/DUCT TYPICAL

#12 HEX HEAD THREADED FASTENER W/

EPDM WASHER (MIN. 3 PER SIDE)

BUILDING WRAP - FULLY FLASH CURB

- SEE SPECIFICATION 072500

H1

FIRE TREATED WOOD NAILERS

2x6 TREATED WOOD

BLOCKING

STRUCTURAL FRAMING, SEE

STRUCTURAL DRAWINGS

EDGE ANGLE, SEE

STRUCTURAL DRAWINGS

EXHAUST/INTAKE VENT CURB

PREMANUFACTURED CURB

VENT/DUCT TYPICAL

FRONT FACE CURB FLASHING -

REFER TO DETAIL 6/A105

#12 HEX HEAD THREADED FASTENER

W/ EPDM WASHER (MIN. 3 PER SIDE)

TURN PANEL LEG 1" MIN. UP CURB

Z-CLIP

NOTE(S):

1. SET Z-CLIP IN 3/4" BUTYL TAPE.

ATTACH W/#8 FLAT TRUSS HEAD,

GALV. STL. THREADED FASTERNER

AT 8# O.C.

BUILDING WRAP - FULLY FLASH CURB

- SEE SPECIFICATION 072500

SEAL ENDS OF Z-CLIP USING COLOR

MATCHING URETHANE SEALANT

M

IN

4" H1

FIRE TREATED WOOD NAILERS

2x6 TREATED WOOD BLOCKING

STRUCTURAL FRAMING, SEE

STRUCTURAL DRAWINGS

EDGE ANGLE, SEE

STRUCTURAL DRAWINGS

6" 4"

OPENING

PRE-MOLDED PIPE FLASHING

W/ALUMINUM BASE SET IN CONT.

BEAD OF URETHANE SEALANT

ø 1'-4 1/2"

PIPE CURB FLASHING BY METAL

ROOF PANEL MANUFACTURER, SEE

SPECIFICATION 074113.16

PANEL SUPPORT

FASTENER #1E 1/4"-14 X 1 1/4"

(5 FOR EACH PANEL)

1'

M

IN

M

AX

1'

FASTENER #1E 1/4"-14 X 1 1/4"

SPACED PER MANUFACTURER

RECOMMENDATIONS

P

LO

T

D A T E

P

LO

T T E D

B Y

C H K 'D

B Y

D E S

IG

N

O F F

IC

E

D E S

IG

N E D

B Y

P R O J E C T

N O

D R A W N

B Y

A P P R O V E D

B Y

U N

IT

E D

S T A T E S

D E P A R T M E N T

O F

T H E

IN

T E R

IO

R

B U R E A U

O F

L A N D

M A N A G E M E N T

D A T E

D E S C R

IP

T

IO

N

M A R K

A P P R O V E D

D A T E

SHEET OF

:3 :5

P M

C U s e rs a lf o n s o ra m ir e z D o c u m e n ts R e vi tL o c a lT e m p N W B L M D O a rc h a lf o n s o ra m ir e z .r vt

R O O F

D E T A

IL

S

A124

N W B L M D O

S H O S H O N E

F

IE

L D

O F F

IC

E

R E P L A C E M E N T

J R C

R H

C U S H

IN

G

T E R R E L L

J R C

B L M

.1 .2

T W

IN

F A L L S

D

IS

T R

IC

T

ID

A H O

64 124

NOT TO SCALEA124

4 DAYLIGHTING TUBE DETAILING

A124

3 TYPICAL PIPE PENETRATION DETAIL

10.50

SCALE IN FEET

A124

1 ROOF CURB - UPSLOPE SIDE

A124

2 ROOF CURB - DOW NSLOPE SIDE10.50

SCALE IN FEET

10.50

SCALE IN FEET

A124

5 LARGE PIPE PENETRATION DETAIL

STUCCO SYSTEM

PER SPECIFICATION

092400

CMU VENEER PER

SPECIFICATION

042613

MATERIALS LEGEND

STANDING SEAM METAL

ROOF PANEL PER

SPECIFICATION

074113.16

FIRST FLOOR

100'-0"

TOP OF WALL

113'-0"

A301

A301

A301

VE VE VE

VA

VC

A301

VE

VA VA VA

VE VE VE VEVE

VC VC VC VC VC VC VC VC VC VC VC

12 23 4

TY

P.

3'

5555555 55555

8 8 8 8 8 89

15689111314151617181920 234710

111111 12 1313 13

12' - 0"

E.Q.E.Q.E.Q.E.Q. EQEQ

FIRST FLOOR

100'-0"

TOP OF WALL

113'-0"

A301

VE VE VE VE VE VE VE VE

5 5 555555

ABCD

2 2 2 2

FIRST FLOOR

100'-0"

TOP OF WALL

113'-0"

A301

VE VE VE VEVE

5 5 5 5 5 8 8 9

A B C D

13222

VF

FIRST FLOOR

100'-0"

TOP OF WALL

113'-0"

A301

A301

A301

VEVEVEVEVD

A301

VE VE VE VE

VB VA VA

VE

6 6 6 6 6 6 6 6 6 68 98 8888

1 5 6 8 9 11 13 14 15 16 17 18 19

2 3 4 7 10

4'

6" TYP. SEE A601 6" TYP.

ALA

13 13 13 13 1311 1111

A311

TYP.

2 2 2 2

VFVFVFVF

22 6666

7'

6 6

A. SEE A100 FOR WALL ASSEMBLY AND ROOF TYPES.

B. SEE CIVIL AND LANDSCAPE DRAWINGS FOR ALL SITE RELATED

ITEMS ADJACENT TO THE BUILDING.

C. CONTROLS IN THE CMU VENEER ARE TO FOLLOW

SPECIFICATION 042613.

D. CONTROLS JOINTS IN THE STUCCO ARE TO FOLLOW

SPECIFICATION 092400.

E. SEE 'DOOR AND WINDOW SCHEDULE' SHEET, A601, FOR

DOOR AND WINDOWS TYPES.

F. SEE ROOF PLANS GUTTER AND DOWNSPOUT DRAIN

LOCATIONS.

G. SEE STRUCTURAL DRAWINGS FOR ALL T.O. WALL

MEASUREMENTS AND TOP OF STEEL MEASUREMENTS.

H. SEE 'DOOR AND WINDOW SCHEDULE' SHEET, A601, FOR

DETAILS AND TRIM LOCATIONS.

I. SEE ELECTRICAL DRAWINGS FOR ALL EXTERIOR LIGHTING AND

ELECTRICAL ITEMS.

J. SEE MECHANICAL DRAWINGS FOR ALL MECHANICAL

EQUIPMENT.

K. CONCRETE FOUNDATION STEM WALL TO BE COVERED WITH

CONCRETE FACED INSULATION BOARD, SEE WALL SECTIONS

AND DETAILS.

L. PAINT ALL EXPOSED STRUCTURAL STEEL PER SPECIFICATION

099113.

M. PAINT ALL EXPOSED MECHANICAL DIFFUSERS TO MATCH

ADJACENT SIDING COLOR.

GENERAL NOTES

P

LO

T

D A T E

P

LO

T T E D

B Y

C H K 'D

B Y

D E S

IG

N

O F F

IC

E

D E S

IG

N E D

B Y

P R O J E C T

N O

D R A W N

B Y

A P P R O V E D

B Y

U N

IT

E D

S T A T E S

D E P A R T M E N T

O F

T H E

IN

T E R

IO

R

B U R E A U

O F

L A N D

M A N A G E M E N T

D A T E

D E S C R

IP

T

IO

N

M A R K

A P P R O V E D

D A T E

SHEET OF

:2 :0

P M

C U s e rs a lf o n s o ra m ir e z D o c u m e n ts R e vi tL o c a lT e m p N W B L M D O a rc h a lf o n s o ra m ir e z .r vt

E X T E R

IO

R

E L E V A T

IO

N S

A201

N W B L M D O

S H O S H O N E

F

IE

L D

O F F

IC

E

R E P L A C E M E N T

J R C

R H

C U S H

IN

G

T E R R E L L

J R C

B L M

.1 .2

T W

IN

F A L L S

D

IS

T R

IC

T

ID

A H O

65 124

# SHEET NOTES

1 STUCCO CONTROL JOINT, TYPICAL. SEE A001 FOR DETAIL.

2 MASONRY CONTROL JOINT, SEALANT TO MATCH COLOR OF CMU

CONTROL JOINT VENEER. SEE STRUCTURAL DRAWINGS FOR CONTROL

JOINT DETAIL.

3 PLUMBING VENT, SEE PLUMBING DRAWINGS.

4 REGLET AND COUNTERFLASHING, SEE ROOF DETAILS ON A120'S

SHEETS.

5 VERTICAL SUN SHADE DEVICE, TO BE ' AGS Inc. P-375 ' 3/8" THICK

ALUMINUM PERFORATED PANELS WITH MANUFACTURER'S STANDARD

PERCENTAGE OF PERFORATION, COLOR TO MATCH HORIZONTAL SUN

SHADE DEVICE. SEE DETAILS ON A603.

6 HORIZONTAL SUN SHADE DEVICE,TO BE 'ARCHITECTURAL LOUVERS H6JN

- 6" DEEP 25 DEGREE NARROW N BLADE EXTRUDED ALUMINUM

STATIONARY SUNSHADE WITH 4" BLADE SPACING, STANDARD TRIM, AND

A BLACK ANODIZED FINISH' OR EQUAL. SEE DETAIL ON A603.

7 TUBULAR DAYLIGHTING DEVICE UNIT SKYLIGHT, SEE SPECIFICATIONS

AND ROOF DETAILS SHEET FOR FURTHER INFORMATION. SEE CEILING

PLAN FOR DAYLIGHT TUBE DIFFUSER LOCATIONS.

8 CMU VENEER AT COLUMN BASE WITH CONCRETE CAP.

9 PRIME AND PAINT ALL EXPOSED STEEL, SEE SPECIFICATION 099113.

10 SNOW GUARD, TYPICAL. SEE ROOF PLAN ON A121 AND SPECIFICATIONS

FOR FURTHER INFORMATION.

11 GUTTER DOWNSPOUT WITH ASSOCIATED GUTTER, COLOR TO MATCH

ROOFING COLOR.

12 ELECTRICAL EQUIPMENT, SEE ELECTRICAL DRAWINGS.

13 EXTERIOR LIGHT FIXTURE, SEE ELECTRICAL DRAWINGS.

A201

1 NORTH ELEVATION

A201

2 EAST ELEVATION

A201

3 WEST ELEVATION

A201

4 SOUTH ELEVATION

SCALE IN FEET

SCALE IN FEET

SCALE IN FEET

T ectonic Cop yright 2007

T ectonic Cop yright 2007T ectonic Cop yright 2007

FIRST FLOOR

100'-0"

A301

FIELD OFFICE/S.S./DISTRICT

STAFF

3" / 1'-0" 1" / 1'-0"

H1

H1

C

D D

C

A303

3______________

A303

SIM. SIM.

OPP.

C

B

A122

FIRST FLOOR

100'-0"

A301

ENTRY HALL

FIRE READY ROOM

WELLNESS

HALL

BREAK AREA

3" / 1'-0"

1" / 1'-0"

LOBBY/ENTRY

H1

H1

D

A302

A303

A A

B

B B

ABD

ALA

VC

VA

A122

A123

FIRST FLOOR

100'-0"

TOP OF W ALL

113'-0"

A301

FIRE SUITE

3" / 1'-0"

1" / 1'-0"

H1

H1

C

C

D D

A302

A303

BC

A123

A122

VE VE

FIRST FLOOR

100'-0"

TOP OF W ALL

113'-0"

A301

FIELD

OFFICE/S.S./DISTRICT

STAFF

FIRE SUITE

A301

A301

VC VC VC VC VC VC VC VC VC

A301

H1 H1

C

D

C

D

FIRE READY

ROOM

R.R.

R.R.

A303

A303

OPP.

VC VC VC

B

B

B 1,3

B

1 6 8 13 15 17 19 20

H1H1

B B

VE

FIRST FLOOR

100'-0"

A301

MAIN CONFERENCE ROOM

FIELD OFFICE

HUDDLE ROOM

PRIVATE OFFICE

PRIVATE OFFICE

SMALL CONFERENCE ROOM

FIELD OFFICE/S.S./DISTRICT

STAFF

C

D

H1

H1

3" / 1'-0"

1" / 1'-0"

A302

A303

SIM.

A303

A

A A

B 1 A

ABD

VF

B 1,3

A122

P

LO

T

D A T E

P

LO

T T E D

B Y

C H K 'D

B Y

D E S

IG

N

O F F

IC

E

D E S

IG

N E D

B Y

P R O J E C T

N O

D R A W N

B Y

A P P R O V E D

B Y

U N

IT

E D

S T A T E S

D E P A R T M E N T

O F

T H E

IN

T E R

IO

R

B U R E A U

O F

L A N D

M A N A G E M E N T

D A T E

D E S C R

IP

T

IO

N

M A R K

A P P R O V E D

D A T E

SHEET OF

:4 :2

P M

C U s e rs a lf o n s o ra m ir e z D o c u m e n ts R e vi tL o c a lT e m p N W B L M D O a rc h a lf o n s o ra m ir e z .r vt

B U

IL

D

IN

G

S E C T

IO

N S

A301

N W B L M D O

S H O S H O N E

F

IE

L D

O F F

IC

E

R E P L A C E M E N T

J R C

R H

C U S H

IN

G

T E R R E L L

J R C

B L M

.1 .2

T W

IN

F A L L S

D

IS

T R

IC

T

ID

A H O

66 124

A301

1 BUILDING SECTION I

A301

2 BUILDING SECTION II

A301

3 BUILDING SECTION III

A301

4 BUILDING SECTION V

SCALE IN FEET

SCALE IN FEET

SCALE IN FEET

SCALE IN FEET

A301

5 BUILDING SECTION IV

FIRST FLOOR

100'-0"

LOBBY/ENTRY

H1

D

A602

A602

A122

METAL SOFFIT PANELS,

TYPICAL AT ALL SOFFITS.

SEE SPECIFICATION

074293. COLOR TO

MATCH COLOR OF

ROOFING PANELS

PRE-FINISHED METAL

GUTTER AND

DOWNSPOUT, SEE

SPECIFICATION

074113.16 AND DETAILS

ON A123

PRIME AND PAINT ALL

EXPOSED EXTERIOR

STEEL, SEE EXTERIOR

PAINT SPECIFICATION

099113

SEE DETAILS ON A311

FOR COLUMN WRAP

DETAILS

ALA

DOWNSPOUT TO HUG

COLUMN AND BASE AS

CLOSE AS POSSIBLE.

A123

SIM

C

FIRST FLOOR

100'-0"

FIRE SUITE

C

D

H1

C

A311

SIM

A602

A602

A122

METAL SOFFIT PANELS,

TYPICAL AT ALL SOFFITS.

SEE SPECIFICATION

074293. COLOR TO

MATCH COLOR OF

ROOFING PANELS

PRE-FINISHED METAL

GUTTER AND

DOWNSPOUT, SEE

SPECIFICATION

074113.16 AND

DETAILS ON A123

PRIME AND PAINT ALL

EXPOSED EXTERIOR

STEEL, SEE EXTERIOR

PAINT SPECIFICATION

099113

SEE DETAILS ON A311

FOR COLUMN WRAP

DETAILS

VE

6'

TY

P.

3'

DOWNSPOUT TO HUG

COLUMN AND BASE AS

CLOSE AS POSSIBLE.

A123

FIRST FLOOR

100'-0"

MAIN CONFERENCE ROOM

FIELD OFFICE

H1

D

A602

A311

SIM

A123

A602

VF

D

6'

TY

P.

3'

A. SEE CIVIL, STRUCTURAL, MECHANICAL, AND ELECTRICAL

DRAWINGS FOR ADDITIONAL REQUIREMENTS AND

COORDINATION.

B. SEE FIRE DRAWINGS FOR ADDITIONAL WORK TO OCCUR AND

ADDITIONAL REQUIREMENTS.

C. SEE A001 AND A101 FOR WALL TYPE INFORMATION AND

LOCATIONS.

D. SEE CODE PLAN FOR INFORMATION ON SQUARE FOOTAGE OF

BUILDING AND OTHER RELATED ITEMS.

E. SEE CODE PLAN FOR ENVELOPE ENERGY REQUIREMENTS.

F. SEE SPECIFICATIONS FOR ALL BUILDING COMPONENTS.

G. SEE EXTERIOR ELEVATIONS ON A201 FOR LOCATIONS OF CMU

VENEER AT BASE OF EXTERIOR WALLS.

H. COORDINATE EXTERIOR WALL DIMENSIONS AND FACE OF STEM

WALL LOCATIONS WITH STRUCTURAL DRAWINGS.

I. DIMENSIONS OF WINDOWS LOCATED WITHIN STUCCO ARE TO

CENTERLINE OF WINDOW. DIMENSIONS TO WINDOWS AND

FRAMES LOCATED WITHIN CMU VEENER ARE TO OUTSIDE OF

ROUGH OPENING.

J. SEE FINISH PLAN ON A501 FOR COORDINATION OF FINISHES

AND OTHER ITEMS MOUNTED ON INTERIOR WALLS.

K. SEE A501 FOR ROLLER SHADE LOCATIONS.

L. PROVIDE METAL STUD BLOCKING IN WALL AS NEEDED FOR

ALL MOUNTED EQUIPMENT, MILLWORK, AND HARDWARE,

COORDINATE WITH WALL TYPES.

GENERAL NOTES

P

LO

T

D A T E

P

LO

T T E D

B Y

C H K 'D

B Y

D E S

IG

N

O F F

IC

E

D E S

IG

N E D

B Y

P R O J E C T

N O

D R A W N

B Y

A P P R O V E D

B Y

U N

IT

E D

S T A T E S

D E P A R T M E N T

O F

T H E

IN

T E R

IO

R

B U R E A U

O F

L A N D

M A N A G E M E N T

D A T E

D E S C R

IP

T

IO

N

M A R K

A P P R O V E D

D A T E

SHEET OF

:3 :2

P M

C U s e rs a lf o n s o ra m ir e z D o c u m e n ts R e vi tL o c a lT e m p N W B L M D O a rc h a lf o n s o ra m ir e z .r vt

W A L L

S E C T

IO

N S

A302

N W B L M D O

S H O S H O N E

F

IE

L D

O F F

IC

E

R E P L A C E M E N T

J R C

R H

C U S H

IN

G

T E R R E L L

J R C

B L M

.1 .2

T W

IN

F A L L S

D

IS

T R

IC

T

ID

A H O

67 124

A302

2 W ALL SECTION II

A302

1 W ALL SECTION I

A302

3 W ALL SECTION III

SCALE IN FEET

SCALE IN FEET

FIRST FLOOR

100'-0"

FIRE SUITE

C

D

H1

A311

SIM

A122

A311

TY

P.

3'

FIRST FLOOR

100'-0"

HUDDLE ROOM

C

H1

H1

B 1,3

B

A122

A122

FIRST FLOOR

100'-0"

FIRE SUITE

C

D

H1

A122

A602

A602

A311

SIM

6'

TY

P.

3'

FIRST FLOOR

100'-0"

BREAK AREA

D

H1

D

A

A602

A311

SIM

A602

A122

METAL SOFFIT PANELS,

TYPICAL AT ALL SOFFITS.

SEE SPECIFICATION

074293. COLOR TO

MATCH COLOR OF

ROOFING PANELS

PRE-FINISHED METAL

GUTTER AND

DOWNSPOUT, SEE

SPECIFICATION

074113.16 AND

DETAILS ON A123

PRIME AND PAINT ALL

EXPOSED EXTERIOR

STEEL, SEE EXTERIOR

PAINT SPECIFICATION

099113

A311

SEE DETAILS ON A311

FOR COLUMN WRAP

DETAILS

4'

TY

P.

3'

DOWNSPOUT TO HUG

COLUMN AND BASE AS

CLOSE AS POSSIBLE.

A123

A. SEE CIVIL, STRUCTURAL, MECHANICAL, AND ELECTRICAL

DRAWINGS FOR ADDITIONAL REQUIREMENTS AND

COORDINATION.

B. SEE FIRE DRAWINGS FOR ADDITIONAL WORK TO OCCUR AND

ADDITIONAL REQUIREMENTS.

C. SEE A001 AND A101 FOR WALL TYPE INFORMATION AND

LOCATIONS.

D. SEE CODE PLAN FOR INFORMATION ON SQUARE FOOTAGE OF

BUILDING AND OTHER RELATED ITEMS.

E. SEE CODE PLAN FOR ENVELOPE ENERGY REQUIREMENTS.

F. SEE SPECIFICATIONS FOR ALL BUILDING COMPONENTS.

G. SEE EXTERIOR ELEVATIONS ON A201 FOR LOCATIONS OF CMU

VENEER AT BASE OF EXTERIOR WALLS.

H. COORDINATE EXTERIOR WALL DIMENSIONS AND FACE OF STEM

WALL LOCATIONS WITH STRUCTURAL DRAWINGS.

I. DIMENSIONS OF WINDOWS LOCATED WITHIN STUCCO ARE TO

CENTERLINE OF WINDOW. DIMENSIONS TO WINDOWS AND

FRAMES LOCATED WITHIN CMU VEENER ARE TO OUTSIDE OF

ROUGH OPENING.

J. SEE FINISH PLAN ON A501 FOR COORDINATION OF FINISHES

AND OTHER ITEMS MOUNTED ON INTERIOR WALLS.

K. SEE A501 FOR ROLLER SHADE LOCATIONS.

L. PROVIDE METAL STUD BLOCKING IN WALL AS NEEDED FOR

ALL MOUNTED EQUIPMENT, MILLWORK, AND HARDWARE,

COORDINATE WITH WALL TYPES.

GENERAL NOTES

P

LO

T

D A T E

P

LO

T T E D

B Y

C H K 'D

B Y

D E S

IG

N

O F F

IC

E

D E S

IG

N E D

B Y

P R O J E C T

N O

D R A W N

B Y

A P P R O V E D

B Y

U N

IT

E D

S T A T E S

D E P A R T M E N T

O F

T H E

IN

T E R

IO

R

B U R E A U

O F

L A N D

M A N A G E M E N T

D A T E

D E S C R

IP

T

IO

N

M A R K

A P P R O V E D

D A T E

SHEET OF

:4 :3

P M

C U s e rs a lf o n s o ra m ir e z D o c u m e n ts R e vi tL o c a lT e m p N W B L M D O a rc h a lf o n s o ra m ir e z .r vt

W A L L

S E C T

IO

N S

A303

N W B L M D O

S H O S H O N E

F

IE

L D

O F F

IC

E

R E P L A C E M E N T

J R C

R H

C U S H

IN

G

T E R R E L L

J R C

B L M

.1 .2

T W

IN

F A L L S

D

IS

T R

IC

T

ID

A H O

68 124

A303

1 W ALL SECTION IV

A303

2 W ALL SECTION V

A303

3 W ALL SECTION VI

A303

4 W ALL SECTION VII

SCALE IN FEET

SCALE IN FEET

SCALE IN FEET

SELF ADHERING THROUGH WALL

FLASHING. LAP UP WALL

WEEPS AT BOTTOM OF MASONRY

VENEER. SPACING AT 24" O.C., SEE

SPECIFICATION 042000

CAVITY DRAINAGE MATERIAL

LIQUID FLASHING TO LAP OVER

METAL FLASHING - INSTALL

SHEATHING PER MANUFACTURER

WRITTEN INSTRUCTIONS

6" STEEL STUD

FRAMING

CONCRETE SLAB ON

GRADE, SEE STRUCTURAL

DRAWINGS, SEE FINISH

PLAN FOR FLOORING

FINISHES

BASE COURSE. SEE

GEOTECHNICAL SOILS

REPORT

BITUMINOUS

DAMP PROOFING

SILL PLATE GASKETING

CONCRETE STEM WALL

PER STRUCTURAL

DRAWINGS

1/2" EXPANSION JOINT,

SEE STRUCTURAL

DRAWINGS

INTERIOREXTERIOR

FULLY GROUT

BEHIND CMU VENEER

BELOW GRADE

GROUT CELLS SOLID

BELOW GRADE

EXPANSION JOINT, SEE

CIVIL DRAWINGS

EXTERIOR PAVING WHERE

OCCURS, SEE CIVIL

DRAWINGS FOR LOCATIONS

AND FINISH GRADE

ELEVATIONS

VAPOR BARRIER BENEATH

CONCRETE SLAB - SEE

S002 FOR BARRIER

INFORMATION

BE

LO

W F

FE

4"

SEE EXTERIOR ELEVATIONS

T.O. CMU

INTERIOR

CONTINUOUS PRE-FINISHED

METAL FLASHING LAPS BEHIND

FLEXIBLE FLASHING - SLOPE

METAL FLASHING

1/4" = 1'-0" TO DRAIN

CASING BEAD WITH

WEEP HOLES

8"X4"X16" UNIT

MASONRY VENEER SILL

UNIT

EXTERIOR

C

D

SEALANT

LIQUID FLASHING TO LAP

OVER METAL FLASHING -

INSTALL PER SHEATHING

MANUFACTURER WRITTEN

INSTRUCTIONS

1/2" 4"

1/2"

1/2" 1/2"

STRUCTURAL STEEL

COLUMN, SEE

STRUCTURAL DRAWINGS.

PRIME AND PAINT ALL

EXPOSED STEEL

SEALANT AT ALL SIDES

OF CONCRETE CAP TO

STEEL TRANSTION

PRECAST CONCRETE

COLUMN CAP SET IN BED

OF MORTAR

1/2" X 4" 316

STAINLESS STEEL

THREADED ROD SET

MORTAR

1/8" KERF AT ALL SIDES

OF COLUMN CAP

4" DEEP X 4" HIGH X 16"

LONG GROUND FACE CMU

BLOCK WITH FULLY

GROUTED CELLS, SEE

STRUCTURAL DRAWINGS FOR

FURTHER INFORMATION

2" 2"

FILL VOID WITH CONRETE

PER STRUCUTRAL DRAWINGS

EQ EQ

JOINT SEALANT AND

BACKING

CMU VENEER

CORNER BLOCK

D

C

SEE: A001 FOR

WALL ASSEMBLIES

P

LO

T

D A T E

P

LO

T T E D

B Y

C H K 'D

B Y

D E S

IG

N

O F F

IC

E

D E S

IG

N E D

B Y

P R O J E C T

N O

D R A W N

B Y

A P P R O V E D

B Y

U N

IT

E D

S T A T E S

D E P A R T M E N T

O F

T H E

IN

T E R

IO

R

B U R E A U

O F

L A N D

M A N A G E M E N T

D A T E

D E S C R

IP

T

IO

N

M A R K

A P P R O V E D

D A T E

SHEET OF

:0 :1

P M

C U s e rs a lf o n s o ra m ir e z D o c u m e n ts R e vi tL o c a lT e m p N W B L M D O a rc h a lf o n s o ra m ir e z .r vt

W A L L

D E T A

IL

S

A311

N W B L M D O

S H O S H O N E

F

IE

L D

O F F

IC

E

R E P L A C E M E N T

J R C

R H

C U S H

IN

G

T E R R E L L

J R C

B L M

.1 .2

T W

IN

F A L L S

D

IS

T R

IC

T

ID

A H O

69 124

A311

3 TYPICAL FOUNDATION SILL DETAIL

SCALE IN FEET

A311

2 TYPICAL CMU SILL TO STUCCO TRANSITION

SCALE IN FEET

A311

1 TYPICAL COLUMN CAP DETAIL

10.50

SCALE IN FEET

A311

5 TYPICAL STUCCO TO CMU VENEER TRANSITION

10.50

SCALE IN FEET

N

O C

D D

C o m m e n t

.0

.2

RB1

RB1

RB1

RB1

RB1

P T

P T

PT4

PT4

PT5

PT3

PT4

PT4

W T

W T

W T

W T

WT5

WT2

WT2

WT4

WT3

WT2

PT5

WT2 WT2

WT2

WT1

WT6

WT5

WT4

WT3

WT2

WT6

WT2 WT2

T B

T B

WT2

WT1

WT2

WT1

WT2

WT1

EXTENT OF ACCENT PAINT OR WALL FINISHES

FLOOR FINISH 'SC1'

SEALED CONCRETE

LOCATION AND TYPE OF CORNER GUARDS

CG

FINISH PLAN LEGEND

FLOORING MATERIAL CHANGE, MATERIAL TYPES

SHOWN ON EACH SIDE OF TRANSITION

ROOM NAME AND NUMBER

FLOOR FINISH 'LVT1'

LUXURY VINYL TILE

FLOOR FINISH 'CP1'

CARPET TILE

INSTALL DIRECTION OF DIRECTIONAL FLOOR FINISH

FINISH TAG

A8## # INTERIOR ELEVATION CALLOUT AND

DIRECTION OF ELEVATION VIEW

NAME

FINISH TAGS DISPLAYED IN GROUPING ON FINISH PLAN

REPRESENT MAJORITY ROOM FINISH SELECTIONS. ORDER OF

GROUPING DEFINED IN EXAMPLE BELOW:

MAJORITY WALL FINISH

MAJORITY BASE FINISH

MAJORITY FLOOR FINISH

FLOORING

BASE

RB1 RUBBER BASE 4" - SEE SPECIFICATION 096513

RB2 RUBBER BASE 6" - SEE SPECIFICATION 096513

TB1 TILE BASE - SEE SPECIFICATION 093013

WALLS

FRP1 FIBERGLASS PANELS - SEE SPECIFICATION 066400

PT# PAINT - SEE SPECIFICATION 099123

WT1 WALL TILE - SEE SPECIFICATION 093013

FLOORING TRANSITIONS

TR1 SC TO CP/LV

TR2 CP TO FT

CASEWORK

PL# PLASTIC LAMINATE - SEE SPECIFICATION 064116 AND

SEPCIFICATION 123623.13

ROOM FINISH ABBREVIATIONS

CP1 CARPET TILE - SEE SPECIFICATION 096813

CP2 WALK OFF CARPET - SEE SPECIFICATION 096813

FT1 FLOOR TILE - SEE SPECIFICATION 093013

LVT1 LUXURY VINYL TILE - SEE SPECIFICATION 096519

SC1 SEALED CONCRETE WITH STAIN - SEE SPECIFICATION 033500

FLOOR FINISH 'CP2'

WALK OFF CARPET

FLOOR FINISH 'FT1'

FLOOR TILE

GENERAL FINISH NOTES

A. MOTORIZED ROLLER SHADES TO BE PROVIDED AT EACH OF THE

FIRE READY ROOM CLERESTORY WINDOWS, SEE ROLLER SHADE

SPECIFICATION 122413.

ENTRY HALL

I.T./PACS

ROOM

HUDDLE

ROOM

WELLNESS

M.R.R.

W.R.R.

111 PRIVATE

OFFICE

HUDDLE

ROOM

PRIVATE

OFFICE

HUDDLE

ROOM

FIRE READY

ROOM

HUDDLE

ROOM

FOCUS

ROOM

FIRE SUITE

MEP

BREAK

AREA

SMALL

CONFERENCE

ROOM

FIELD

OFFICE/S.S./DISTRICT

STAFF

JAN.

STAFF

VESTIBULE

STAFF

VESTIBULE

VESTIBULE

OFFICE

SUPPLY/PLOTTER

ROOM

RECEPTION

LOBBY/ENTRY

MAIN

CONFERENCE

ROOM FIELD

OFFICE

MAIL ROOM

R.R.

R.R.

HALL

RS1RS1RS1RS1

RS1

RS1

RS1

RS1

RS1

RS1 RS1 RS1 RS1

RS1 RS1

RS1 RS1 RS1 RS1 RS1

RS1 RS1 RS1 RS1 RS1

RS1

RS1RS1

RS1

RS1

RS1

RS1

RS1

RS1

RS1

RS1

RS1

RS1

RS1

RS1

RS1

SMALL

CONFERENCE

ROOM

CG

CG

CG

CG CG CG

CGCG

CG

CG

CG

CGCG

CG

CG

CGCG

CG

CG

CG

CG

CG

IT STRG.

117A 1

CG CG CG CG

CG CG

RS1RS1RS1

CG

FIELD

OFFICE/S.S./DISTRICT

STAFF

CG

CGCG

CG

P

LO

T

D A T E

P

LO

T T E D

B Y

C H K 'D

B Y

D E S

IG

N

O F F

IC

E

D E S

IG

N E D

B Y

P R O J E C T

N O

D R A W N

B Y

A P P R O V E D

B Y

U N

IT

E D

S T A T E S

D E P A R T M E N T

O F

T H E

IN

T E R

IO

R

B U R E A U

O F

L A N D

M A N A G E M E N T

D A T E

D E S C R

IP

T

IO

N

M A R K

A P P R O V E D

D A T E

SHEET OF

:4 :3

P M

C U s e rs a lf o n s o ra m ir e z D o c u m e n ts R e vi tL o c a lT e m p N W B L M D O a rc h a lf o n s o ra m ir e z .r vt

F

IN

IS

H

P L A N

A501

N W B L M D O

S H O S H O N E

F

IE

L D

O F F

IC

E

R E P L A C E M E N T

J R C

R H

C U S H

IN

G

T E R R E L L

J R C

B L M

.1 .2

T W

IN

F A L L S

D

IS

T R

IC

T

ID

A H O

70 124

# KEYNOTES

1 WALLS TO RECEIVE FRP1 UP TO 48" A.F.F. (ABOVE FINISH FLOOR).

2 WALL MOUNTED WHITEBOARD, (VISUAL DISPLAY UNIT) VDU1, WHERE

NOTED. MOUNT 2'-10" ABOVE FINISH FLOOR. SEE SPECIFICATIONS

FOR FURTHER INFORMATION.

3 UPPER CLERESTORY WINDOWS WITHIN ROOM NOTED ARE ALL TO

RECIEVE MOTORIZED ROLLER SHADES. SEE ROOF PLAN FOR WINDOW

LOCATIONS AND ELECTRICAL DRAWINGS FOR CONNECTIONS.

A501

1 FINISH PLAN

NORTH REF

SCALE IN FEET

ROOM FINISH SCHEDULE

ROOM

NUMBER

ROOM

NAME

FLOOR BASE

WALLS

ADDITIONAL NOTES

NORTH EAST SOUTH WEST

117 I.T./PACS ROOM SC1 RB1 PT1 PT1 PT1 PT1

117A IT STRG. SC1 RB1 PT1 PT1 PT1 PT1

118 HUDDLE ROOM CP1 RB1 PT1 PT1 PT1 PT1

119 SMALL CONFERENCE ROOM CP1 RB1 PT1 PT1 PT1 PT1

120 STAFF VESTIBULE CP2 RB1 PT1 PT1 PT1 PT1

121 HUDDLE ROOM CP1 RB1 PT1 PT1 PT1 PT1

122 FIRE SUITE CP1 RB1 PT1 PT1 PT1 PT1

123 HUDDLE ROOM CP1 RB1 PT1 PT1 PT1 PT1

124 FOCUS ROOM CP1 RB1 PT1 PT1 PT1 PT1

125 FIRE READY ROOM CP1/LVT

RB1 PT1 PT1 PT1 PT1

126 VESTIBULE CP2 RB1 PT1 PT1 PT1 PT1

127 MAIL ROOM CP1 RB1 PT1 PT1 PT1 PT1

128 OFFICE SUPPLY/PLOTTER ROOM CP1 RB1 PT1 PT1 PT1 PT1

129 RECEPTION CP1 RB1 PT1 PT1 PT1 PT1

130 R.R. FT1 TB1/TR# PT1/WT1 PT1/WT1 PT1/WT1 PT1/WT1

131 R.R. FT1 TB1/TR# PT1/WT1 PT1/WT1 PT1/WT1 PT1/WT1

132 MAIN CONFERENCE ROOM FIELD OFFICE CP1 RB1 PT1 PT1 PT1 PT1

ROOM FINISH SCHEDULE

ROOM

NUMBER

ROOM

NAME

FLOOR BASE

WALLS

ADDITIONAL NOTES

NORTH EAST SOUTH WEST

101 LOBBY/ENTRY CP2 RB1 PT1 PT1 PT1 PT1

102 ENTRY HALL CP1 RB1 PT1 PT1 PT1 PT1

103 FIELD OFFICE/S.S./DISTRICT STAFF CP1 RB1 PT1 PT1 PT1 PT2

104 FIELD OFFICE/S.S./DISTRICT STAFF CP1 RB1 PT1 PT1 PT1 PT1

105 HUDDLE ROOM CP1 RB1 PT1 PT1 PT1 PT1

106 PRIVATE OFFICE CP1 RB1 PT1 PT1 PT1 PT1

107 PRIVATE OFFICE CP1 RB1 PT1 PT1 PT1 PT1

108 SMALL CONFERENCE ROOM CP1 RB1 PT1 PT1 PT1 PT1

109 STAFF VESTIBULE CP2 RB1 PT1 PT1 PT1 PT1

110 M.R.R. FT1 TB1/TR# PT1/WT1/WT2 PT1/WT1/WT2 PT1/WT1/WT2 PT1/WT1/WT2

111 W.R.R. FT1 TB1/TR# PT1/WT1/WT2 PT1/WT1/WT2 PT1/WT1/WT2 PT1/WT1/WT2

112 HALL CP1 RB1 PT1 PT1 PT1 PT1

113 MEP SC1 RB2 PT1 PT1 PT1 PT1

114 BREAK AREA LVT1 RB1 PT1 PT1 PT1/WT3/WT4/WT5/WT6/W

T7

PT1

115 JAN. SC1 RB2 PT1/FRP1 PT1/FRP1 PT1 PT1

116 WELLNESS CP1 RB1 PT1 PT1 PT1/WT2 PT1

DOOR NOTES

1. DOOR TO HAVE 180 DEGREE OPENING DOOR SWING.

2. DOOR AND FRAME ARE LOCATED ON THE INTERIOR OF THE

BUILDING.

3. DOOR TO RECIEVE POSITION SENSOR PER ELECTRICAL DRAWINGS.

4. DOOR TO BE UNDERCUT FOR MECHANICAL AIR TRANSFER.

5. RIM EXIT DEVICE TO HAVE TRIM WITH KEY CONTROL LEVER ON

THE EXTERIOR. KEYED LOCKSET TO BE USED FOR EMERGENCIES IN

EVENT OF A PACS SYSTEM FAILURE - COORDINATE KEYING WITH

GOVERNMENT.

HARDWARE GROUPSABBREVIATIONS

AL ALUMINUM

HM HOLLOW METAL

IHM INSULATED HOLLOW METAL

IN 1" INSULATED TEMPERED GLAZING

T 1/4" TEMPERED GLAZING

WD SOLID CORE WOOD

FF FACTORY FINISH

PT# PAINT (REFERENCE INTERIOR/EXTERIOR PAINT SPECIFICATION)

SET 1

• LOCK SET (OFFICE)

• HINGES

• WALL STOP

• SILENCER

SET 2

• LOCK SET (STOREROOM)

• HINGES

• WALL STOP

• SILENCER

• MANUAL FLUSH BOLT AT

TOP AND BOTTOM AT

PAIRS OF DOORS ON

FIXED LEAF

SET 3

• PASSAGE LATCH

• HINGES

• WALL STOP

• SILENCER

• SURFACE CLOSER

SET 4

• LOCK SET (BATH)

• HINGES

• WALL STOP

• SILENCER

SET 5

• LOCK SET (STOREROOM)

• HINGES

• WEATHERSTRIP

• THRESHOLD

SET 6

• OFFSET HINGES (SECURITY WITH

NON-REMOVABLE PINS AND

SECURITY STUD) -

• RIM EXIT DEVICE

• SURFACE CLOSER

• THRESHOLD

• AUTOMATIC DOOR OPERATOR

• POWER SUPPLY

• ACTUATION SWITCHES

• DOOR POSITION SENSOR

• STRIKE PLATE PROTECTOR

SET 7

• SECURITY HINGES WITH NON-

REMOVABLE PINS AND SECURITY

STUD

• EPT-10 POWER TRANSFER

• ELECTRIC RIM EXIT DEVICE

• SURFACE CLOSER

• FLOOR STOP

• SECURE CARD ACCESS, J-BOX

FOR ELECTRIFIED DOOR

HARDWARE FUNCTION

• DOOR POSITION SENSOR

• STRIKE PLATE PROTECTOR

• WEATHERSTRIP

• SWEEP

• THRESHOLD

SET 8

• OFFSET HINGES (SECURITY WITH

NON-REMOVABLE PINS AND

SECURITY STUD) -

• RIM EXIT DEVICE

• SURFACE CLOSER

• THRESHOLD

• AUTOMATIC DOOR OPERATOR

• POWER SUPPLY

• ACTUATION SWITCHES

• DOOR POSITION SENSOR

• STRIKE PLATE PROTECTOR

• WEATHERSTRIP

• SWEEP

• THRESHOLD

SET 9

• LOCK SET - LEVER - ELECTRIFIED

MORTISE LOCK (FAIL SECURE)

• SECURITY HINGES WITH NON-

REMOVABLE PINS AND SECURITY

STUD (WITH ELECTRIC MIDDLE

HINGE)

• POWER TRANSFER DEVICE

• SECURE CARD ACCESS, J-BOX

FOR ELECTRIFIED DOOR HARDWARE

• FUNCTION

• SURFACE CLOSER

• WALL STOP

• SILENCER

• DOOR POSITION SENSOR

• STRIKE PLATE PROTECTOR

SET 10

• RIM EXIT DEVICE

• HINGES

• SILENCER

• CLOSER

• WALL STOP

SET 11

• ELECTRIC RIM EXIT DEVICE

• SECURITY HINGES WITH NON-

REMOVABLE PINS AND SECURITY

STUD (WITH ELECTRIC MIDDLE

HINGE)

• POWER TRANSFER DEVICE

• SECURE CARD ACCESS, J-BOX

FOR ELECTRIFIED DOOR HARDWARE

• SURFACE CLOSER

• WALL STOP

• SILENCER

• DOOR POSITION SENSOR

• STRIKE PLATE PROTECTOR

A. FOR FRAME TYPE LOCATIONS, SEE FLOOR PLAN SHEETS.

B. FOR ALUMINUM FRAMED HARDWARE GROUPS, SEE SPECIFICATION

DIVISION 8, SECTION "ALUMINUM - FRAMED ENTRANCES AND

STOREFRONTS." FOR ALL OTHER OPENING HARDWARE GROUPS, SEE

SPECIFICATION DIVISION 8, SECTION "DOOR HARDWARE."

C. FIELD VERIFY ALL ROUGH OPENING DIMENSIONS PRIOR TO

FABRICATION/ INSTALLATION.

D. PROVIDE ONE ELECTRICAL CONDUIT RUN FROM DOOR STRIKE TO

ABOVE ADJACENT CEILING SPACE AS NEEDED FOR DOORS TO

RECEIVE ELECTRIC HARDWARE. REFERENCE ELECTRICAL DRAWINGS FOR

ALL ELECTRIFIED DOOR HARDWARE ITEMS.

E. PAINT ALL HOLLOW METAL DOORS AND FRAMES PER SPECIFICATION

DIVISION 9.

F. 'AC' AT THE END OF THE DOOR NUMBER INDICATES DOOR TO HAVE

ACCESS CONTROL, SEE HARDWARE GROUP, SPECIFICATIONS AND

ELECTRICAL DRAWINGS FOR FURTHER INFORMATION.

HOLLOW METAL DOORS AND DOOR FRAMES ARE TO BE INSULATED AT

ALL EXTERIOR DOOR LOCATIONS.

GENERAL NOTES

VA VB VC

VINYL WINDOW TYPE ELEVATIONS

4' - 0"

4'

3'

3' - 4"

4'

3'

2'

SE

E

EL

EV

AT

IO

N S

4' - 6"

VE

4' - 6"

2'

4'

3'

VD

3' - 0"

2'

4'

3'

"1

VF

3'

4'

2'

4' - 0"

*NOTE: ALL EXTERIOR WINDOWS TO USE INSULATED LAMINATED GLASS (GL-3), EXCEPT FOR WINDOW TYPE 'VC'.

WINDOW TYPE 'VC' TO USE INSULATED GLASS (GL-2).

A B C

DOOR TYPES

SEE SCHED.

SE

E

SC

H

ED

SE

E

SC

H

ED

SEE SCHED.

SE

E

SC

H

ED

SEE SCHED.

3'

2'

1'

8" 8"

1 2

HOLLOW METAL DOOR

FRAME TYPES

*NOTE: 4" HEAD OF FRAME

AT FRAMES IN EXTERIOR

VENEER LOCATIONS

2" SEE SCHED. 2"

2"

SE

E

SC

H

ED

2" SEE SCHED. 2"

1' - 6" 2"

2"

SE

E

SC

H

ED

3"

2"

SEE SCHED.

2" 1' - 6" 2"

2" 1'

4"

SE

E

SC

H

ED

3"

T T

2" SEE SCHED. 2"

1' - 0"

2"

2"

SE

E

SC

H

ED

3"

T

SE

E

SC

H

ED

4"

4" SEE SCHED. 4"

STOREFRONT FRAME TYPE ELEVATIONS

ALA

IN

IN IN

IN

IN IN

10' - 4"

9'

2"

1' - 8"

2"

3' - 0"

2"

3' - 0"

2"

1' - 10"

2"

2"

2'

2"

6'

0"

2"

4" 2'

7"

ALB

10' - 4"

9'

*INTERIOR DOOR AND FRAME

T T T

T T

T

2"

EQ

2"

2' - 11"

2"

2' - 11"

2"

EQ

2"

2"

2'

2"

6'

0"

2" H

INTERIOR ALUMINUM FRAMES

2'

3'

1"

4' - 0"

*NOTE: WINDOW TYPE 'H' TO BE 'CRL HORIZONTAL SLIDING DAISY MODEL PASS-THRU

ASSEMBLY WITH D4 OVERHEAD TRACK WITH JAMBS' OR EQUAL. FRAME COLOR TO BE SATIN

ANODIZED. PROVIDE ASSOCIATED KETED LOCK AND NECESSARY GLAZING. INSTALL PER

MANUFACTURER RECOMMENDATIONS AND INSTRUCTIONS. KEYING TO BE TIED INTO OVERALL

BUILDING KEY SYSTEM.

P

LO

T

D A T E

P

LO

T T E D

B Y

C H K 'D

B Y

D E S

IG

N

O F F

IC

E

D E S

IG

N E D

B Y

P R O J E C T

N O

D R A W N

B Y

A P P R O V E D

B Y

U N

IT

E D

S T A T E S

D E P A R T M E N T

O F

T H E

IN

T E R

IO

R

B U R E A U

O F

L A N D

M A N A G E M E N T

D A T E

D E S C R

IP

T

IO

N

M A R K

A P P R O V E D

D A T E

SHEET OF

:4 :1

P M

C U s e rs a lf o n s o ra m ir e z D o c u m e n ts R e vi tL o c a lT e m p N W B L M D O a rc h a lf o n s o ra m ir e z .r vt

D O O R

A N D

W

IN

D O W

S C H E D U L E S

A N D

D E T A

IL

S

A601

N W B L M D O

S H O S H O N E

F

IE

L D

O F F

IC

E

R E P L A C E M E N T

J R C

R H

C U S H

IN

G

T E R R E L L

J R C

B L M

.1 .2

T W

IN

F A L L S

D

IS

T R

IC

T

ID

A H O

71 124

DOOR SCHEDULE

DOOR

NUMBER

ROOM

NUMBER

ROOM NAME

DOOR FRAME HARDWARE

DOOR

NUMBER

SIZE

MTL TYPE

FINISH

GLAZE NOTES MTL TYPE

FRAME

FINISH

GROUP

W H T

101-1 101 LOBBY/ENTRY 3'-0" 7'-0" 1 3/4" AL C FF IN 3 AL ALA FF 8 101-1

101-2 101 LOBBY/ENTRY 3'-0" 7'-0" 1 3/4" AL C FF IN 3 AL ALA FF 8 101-2

101-3 101 LOBBY/ENTRY 6'-0" 7'-0" 1 3/4" AL C FF T 3 AL ALB FF 6 101-3

103-1 103 FIELD OFFICE/S.S./DISTRICT STAFF 3'-0" 7'-0" 1 3/4" WD B FF T HM 1 PT2 10 103-1

104-1AC 104 FIELD OFFICE/S.S./DISTRICT STAFF 3'-0" 7'-0" 1 3/4" WD B FF T 3 HM 1 PT2 11 104-1AC

105-1 105 HUDDLE ROOM 3'-0" 7'-0" 1 3/4" WD A FF - HM 3 PT2 1 105-1

106-1 106 PRIVATE OFFICE 3'-0" 7'-0" 1 3/4" WD A FF - HM 3 PT2 1 106-1

107-1 107 PRIVATE OFFICE 3'-0" 7'-0" 1 3/4" WD A FF - HM 3 PT2 1 107-1

108-1 108 SMALL CONFERENCE ROOM 3'-0" 7'-0" 1 3/4" WD A FF - HM 2 PT2 3 108-1

109-1AC 109 STAFF VESTIBULE 3'-0" 7'-0" 1 3/4" IHM B FF IN 3,5 IHM 1 PT3 7 109-1AC

109-2 109 STAFF VESTIBULE 3'-0" 7'-0" 1 3/4" WD B FF T HM 1 PT2 10 109-2

110-1 110 M.R.R. 3'-0" 7'-0" 1 3/4" WD A FF - HM 1 PT2 3 110-1

111-1 111 W.R.R. 3'-0" 7'-0" 1 3/4" WD A FF - HM 1 PT2 3 111-1

112-1 112 HALL 2'-0" 7'-0" 1 3/4" WD A FF - HM 1 PT2 2 112-1

113-1 113 MEP 4'-0" 7'-0" 1 3/4" IHM A FF - 3 IHM 5 PT2 5 113-1

114-1AC 114 BREAK AREA 3'-0" 7'-0" 1 3/4" IHM B FF IN 3 IHM 1 PT3 7 114-1AC

114-2 114 BREAK AREA 3'-0" 7'-0" 1 3/4" WD B FF T HM 1 PT2 3 114-2

115-1 115 JAN. 3'-0" 7'-0" 1 3/4" WD A FF - HM 1 PT2 2 115-1

116-1 116 WELLNESS 3'-0" 7'-0" 1 3/4" WD A FF - HM 1 PT2 4 116-1

117-1AC 117A IT STRG. 3'-0" 7'-0" 1 3/4" WD A FF - 3 HM 1 PT2 9 117-1AC

117-2AC 117 I.T./PACS ROOM 3'-0" 7'-0" 1 3/4" WD A FF - 3,4 HM 1 PT2 9 117-2AC

118-1 118 HUDDLE ROOM 3'-0" 7'-0" 1 3/4" WD B FF T HM 1 PT2 3 118-1

119-1 119 SMALL CONFERENCE ROOM 3'-0" 7'-0" 1 3/4" WD B FF T HM 1 PT2 3 119-1

120-1AC 120 STAFF VESTIBULE 3'-0" 7'-0" 1 3/4" IHM B FF IN 3,5 IHM 1 PT3 7 120-1AC

120-2 120 STAFF VESTIBULE 3'-0" 7'-0" 1 3/4" WD B FF T HM 1 PT2 10 120-2

121-1 121 HUDDLE ROOM 3'-0" 7'-0" 1 3/4" WD A FF - HM 3 PT2 1 121-1

122-1 122 FIRE SUITE 3'-0" 7'-0" 1 3/4" WD B FF T HM 1 PT2 10 122-1

122-2AC 122 FIRE SUITE 3'-0" 7'-0" 1 3/4" WD B FF T 3 HM 1 PT2 11 122-2AC

123-1 123 HUDDLE ROOM 3'-0" 7'-0" 1 3/4" WD A FF - HM 3 PT2 1 123-1

124-1 124 FOCUS ROOM 3'-0" 7'-0" 1 3/4" WD A FF - HM 3 PT2 1 124-1

125-1 125 FIRE READY ROOM 3'-0" 7'-0" 1 3/4" WD B FF T HM 4 PT2 10 125-1

125-2AC 125 FIRE READY ROOM 3'-0" 7'-0" 1 3/4" WD B FF T 3 HM 4 PT2 11 125-2AC

126-1AC 126 VESTIBULE 3'-0" 7'-0" 1 3/4" IHM B FF IN 3 IHM 1 PT 7 126-1AC

126-2AC 126 VESTIBULE 3'-0" 7'-0" 1 3/4" WD B FF T 2 HM 1 PT2 11 126-2AC

127-1AC 127 MAIL ROOM 3'-0" 7'-0" 1 3/4" WD A FF - 3 HM 1 PT2 9 127-1AC

128-1AC 128 OFFICE SUPPLY/PLOTTER ROOM 3'-0" 7'-0" 1 3/4" WD A FF - 3 HM 1 PT2 9 128-1AC

128-2AC 128 OFFICE SUPPLY/PLOTTER ROOM 3'-0" 7'-0" 1 3/4" WD A FF - 1 HM 1 PT2 9 128-2AC

129-1AC 129 RECEPTION 3'-0" 7'-0" 1 3/4" WD A FF - 3 HM 1 PT2 9 129-1AC

130-1 130 R.R. 3'-0" 7'-0" 1 3/4" WD A FF - HM 1 PT2 4 130-1

131-1 131 R.R. 3'-0" 7'-0" 1 3/4" WD A FF - HM 1 PT2 4 131-1

132-1AC 132 MAIN CONFERENCE ROOM FIELD OFFICE 3'-0" 7'-0" 1 3/4" WD B FF T 3 HM 4 PT2 11 132-1AC

132-2AC 132 MAIN CONFERENCE ROOM FIELD OFFICE 3'-0" 7'-0" 1 3/4" WD B FF T 3 HM 4 PT2 11 132-2AC jbeagle Text Box See Clarification 1.04 - Doors shall be prepped for access control, however, no PACS system will be installed under subject contract jbeagle Highlight

GRID

SEE A001 FOR

WALL ASSEMBLIES

SILL BEYOND

C

FOAM IN PLACE

INSULATION - FILL

CAVITY

2 1/2" COLD FORMED

METAL FRAMING

SHIM AS REQUIRED

NOTE: INSTALL LIQUID

FLASHING FOR OPENING

PER SHEATHING

MANUFACTURER WRITTEN

INSTRUCTIONS

JOINT SEALANT/

BACKING (EACH SIDE)

VINYL WINDOW

4"

GRID

C

6" COLD FORMED METAL

FRAMING, SEE THE

STRUCTURAL DRAWINGS

FOAM IN PLACE

INSULATION - FILL

CAVITY

2 1/2" COLD FORMED

METAL FRAMING

LIQUID FLASHING

INSTALL PER SHEATHING

MANUFACTURER WRITTEN

INSTRUCTIONS

CONTINUOUS PRE-

FINISHED SHEET

METAL AND TRIM

DRIP FLASHING

ALUMINUM FRAMED

ENTRANCES AND STOREFRONT

FRAME SYSTEM

GLASS UNIT

AS SCHEDULED

JOINT SEALANT/

BACKING EACH

SIDE

CONTINUOUS V-

GROOVE DRIP EDGE

(HEAD)

SEE A001 FOR

WALL ASSEMBLIES

SEE A601

B.O. FRAMING

SHIM AS REQUIRED

NOTE: INSTALL LIQUID

FLASHING FOR OPENING

PER SHEATHING

MANUFACTURER WRITTEN

INSTRUCTIONS

4"

2 1/2"

C

GRID

JAMB

BEYOND/BEHIND

SEE A001 FOR

WALL ASSEMBLIES

FOAM IN PLACE

INSULATION - FILL

CAVITY

6" COLD FORMED

METAL FRAMING

PRE-FINISHED METAL

SILL PAN FLASHING

WITH END DAMS AT

SILL

JOINT SEALANT

SEE A601

T.O. FRAMING

SHIM AS REQUIRED

JOINT SEALANT/

BACKING EACH SIDE

NOTE: INSTALL LIQUID

FLASHING FOR OPENING

PER SHEATHING

MANUFACTURER WRITTEN

INSTRUCTIONS

LIQUID FLASHING

INSTALL PER SHEATHING

MANUFACTURER WRITTEN

INSTRUCTIONS

4"

8"X4"X16" UNIT

MASONRY VENEER SILL

UNIT

GRID

VINYL WINDOW

PREFINISHED METAL SILL

PAN FLASHING WITH

END DAMS

5/8" GLASSMAT

GYPSUM SHEATHING

JOINT SEALANT

AND BACKING

FOAM IN PLACE INSULATION

SEE A601

T.O. FRAMING

MASONRY VENEER

SEE A001 FOR WALL

ASSEMBLIES

LIQUID FLASHING

INSTALL PER SHEATHING

MANUFACTURER WRITTEN

INSTRUCTIONS

FIRE TREATED WOOD

BLOCKING AS REQUIRED

NOTE: INSTALL LIQUID

FLASHING FOR OPENING

PER SHEATHING

MANUFACTURER WRITTEN

INSTRUCTIONS

SOLID SURFACE SILL - SEE

SPECIFICATION 123661.16

EXTEND SILL 1/2" PAST THE

OUTER EDGE OF THE WINDOW

OPENING.

2"

4"

D

JOINT SEALANT AND BACKING

2 1/2" COLD FORMED

METAL FRAMING

SHIM AS REQUIRED

D

GRID

SHIM AS REQUIRED

JOINT SEALANT/

BACKING (EACH SIDE)

SEE: A001 FOR

WALL ASSEMBLIES

FOAM IN PLACE

INSULATION -

FILL CAVITY

CMU VENEER

CORNER BLOCK NOTE: INSTALL LIQUID

FLASHING FOR OPENING

PER SHEATHING

MANUFACTURER WRITTEN

INSTRUCTIONS

2 1/2"

WINDOW AND FRAME

PER SCHEDULE

SET IN BED OF SEALANT

JOINT

SEALANT

SLOPE

FLASHING PAN

EXTERIOR CONCRETE,

SEE LANDSCAPE AND

CIVIL DRAWINGS

SEALANT OVER

EXPANSION

MATERIAL

SEE STRUCTURAL

DRAWINGS FOR

STRUCTURAL CONCRETE

WORK

VAPOR BARRIER BENEATH

CONCRETE SLAB - SEE

S002 FOR BARRIER

INFORMATION

1/2" EXPANSION JOINT,

SEE STRUCTURAL

DRAWINGS

GRID

C

6" COLD FORMED METAL

FRAMING, SEE THE

STRUCTURAL DRAWINGS

FOAM IN PLACE

INSULATION - FILL

CAVITY

2 1/2" COLD FORMED

METAL FRAMING

LIQUID FLASHING

INSTALL PER SHEATHING

MANUFACTURER WRITTEN

INSTRUCTIONS

CONTINUOUS PRE-

FINISHED SHEET

METAL AND TRIM

DRIP FLASHING

VINYL WINDOW

JOINT SEALANT/

BACKING

CONTINUOUS V-

GROOVE DRIP EDGE

(HEAD)

SEE A001 FOR

WALL ASSEMBLIES

SEE A601

B.O. FRAMING

NOTE: INSTALL LIQUID

FLASHING FOR OPENING

PER SHEATHING

MANUFACTURER WRITTEN

INSTRUCTIONS

4"

GRID

D

6" COLD FORMED METAL

FRAMING

FOAM IN PLACE

INSULATION - FILL CAVITY

2 1/2" COLD FORMED

METAL FRAMING

LIQUID FLASHING

INSTALL PER SHEATHING

MANUFACTURER WRITTEN

INSTRUCTIONS

CONTINUOUS PRE-

FINISHED SHEET METAL

AND TRIM DRIP

FLASHING

VINYL WINDOW

JOINT SEALANT/

BACKING

SEE A001 FOR

WALL ASSEMBLIES

SEE A601

B.O. FRAMING

SEALANT STRUCTURAL STEEL

LINTEL - SEE

STRUCTURAL DRAWINGS

NOTE: INSTALL LIQUID

FLASHING FOR OPENING

PER SHEATHING

MANUFACTURER WRITTEN

INSTRUCTIONS

WEEPS AT BOTTOM OF

MASONRY VENEER. SPACING

AT 24" O.C., SEE

SPECIFICATION 042000

CAVITY DRAINAGE MATERIAL

4"

D

GRID

SHIM AS REQUIRED

JOINT SEALANT/

BACKING (EACH SIDE)

SEE: A001 FOR

WALL ASSEMBLIES

FOAM IN PLACE

INSULATION - FILL

CAVITY

CMU VENEER

CORNER BLOCK

NOTE: INSTALL LIQUID

FLASHING FOR OPENING

PER SHEATHING

MANUFACTURER WRITTEN

INSTRUCTIONS

FIRE TREATED

BLOCKING AS

REQUIRED

P

LO

T

D A T E

P

LO

T T E D

B Y

C H K 'D

B Y

D E S

IG

N

O F F

IC

E

D E S

IG

N E D

B Y

P R O J E C T

N O

D R A W N

B Y

A P P R O V E D

B Y

U N

IT

E D

S T A T E S

D E P A R T M E N T

O F

T H E

IN

T E R

IO

R

B U R E A U

O F

L A N D

M A N A G E M E N T

D A T E

D E S C R

IP

T

IO

N

M A R K

A P P R O V E D

D A T E

SHEET OF

:4 :1

P M

C U s e rs a lf o n s o ra m ir e z D o c u m e n ts R e vi tL o c a lT e m p N W B L M D O a rc h a lf o n s o ra m ir e z .r vt

D O O R

A N D

W

IN

D O W

D E T A

IL

S

A602

N W B L M D O

S H O S H O N E

F

IE

L D

O F F

IC

E

R E P L A C E M E N T

J R C

R H

C U S H

IN

G

T E R R E L L

J R C

B L M

.1 .2

T W

IN

F A L L S

D

IS

T R

IC

T

ID

A H O

72 124

3" = 1'-0"A602

5 VINYL W INDOW JAMB DETAIL AT STUCCO

3" = 1'-0"A602

1 STOREFRONT W INDOW HEAD DETAIL AT STUCCO

3" = 1'-0"A602

8 VINYL W INDOW SILL AT STUCCO/CLERESTORY W INDOW S

3" = 1'-0"A602

9 VINYL W INDOW SILL AT CMU VENEER

3" = 1'-0"A602

4 STOREFRONT W INDOW JAMB AT CMU VENEER

3" = 1'-0"A602

7 TYPICAL STOREFRONT FRAMING SILL AT SIDEW ALK

3" = 1'-0"A602

2 VINYL W INDOW HEAD DETAIL AT STUCCO

3" = 1'-0"A602

3 VINYL W INDOW HEAD DETAIL AT CMU VENEER

3" = 1'-0"A602

6 VINYL W…