These documents are detailed mechanical, electrical, and HVAC design plans for a new office building project. The plans include comprehensive technical drawings covering ventilation ductwork, piping layouts, mechanical yard configurations, electrical power distribution, lighting plans, fire alarm systems, data infrastructure, and utility connections. Key technical specifications include a 300 kVA pad-mount transformer, 208/120V electrical service, multiple branch electrical panels, energy recovery ventilation systems, and heat pump terminal units. The design appears to incorporate sophisticated building systems with considerations for energy efficiency, including solar photovoltaic integration, ground source electrical grounding, and zoned mechanical systems with multiple air handling units.

The drawings provide intricate details on equipment mounting, conduit routing, cable management, ground bar configurations, and system interconnections across multiple building zones. Electrical plans show detailed circuit layouts, receptacle placements, lighting fixture specifications, and control systems. The mechanical plans include extensive ductwork routing, equipment placement, and support structure details. The overall design suggests a modern, technologically advanced office facility with integrated mechanical, electrical, and communication infrastructure designed to meet contemporary building performance and sustainability standards.

View the file

Other files

File Type Posted
Sol_140L0625R0002_Amd_0008.pdf PDF
B08_Attachment_19_Revised_Final_Specifications_8-7-25_0007.pdf PDF
B08_Attachment_20C_Revised_Final_Drawings_20250804_Part3_0007.pdf PDF
B08_Attachment_20D_Revised_Final_Drawings_20250804_Part4_0007.pdf PDF
B08_Attachment_20A_Revised_Final_Drawings_20250804_Part1_0007.pdf PDF
B08_Attachment_20B_Revised_Final_Drawings_20250804_Part2_0007.pdf PDF
Sol_140L0625R0002_Amd_0007.pdf PDF
B08_Attachment_18_Q_A_4_25R0002_0007.pdf PDF
Sol_140L0625R0002_Amd_0006.pdf PDF
B08_Attachment_17_J_A_140L0625R0002_0005.pdf PDF
Sol_140L0625R0002_Amd_0005.pdf PDF
B08_Attachment_16_Q_A_3__25R0002_0004.pdf PDF
Sol_140L0625R0002_Amd_0004.pdf PDF
Sol_140L0625R0002_Amd_0003.pdf PDF
B08_Attachment_15_Past_Perf_Questionnaire_UPDATED_0002.docx DOCX document
B08_Attachment_14_Q_A_2__25R0002_0002.docx DOCX document
Sol_140L0625R0002_Amd_0002.pdf PDF
B08_Attachment_12_Q_A_1_0001.pdf PDF
B08_Attachment_13_Site_Visit_Sign-In_Sheet_0001.pdf PDF
Sol_140L0625R0002_Amd_0001.pdf PDF
B08_Attachment_3_Price_Breakout.xlsx XLSX spreadsheet
B08_Attachment_1B_Shoshone_Drawings_8-14.pdf PDF
B08_Attachment_2B_Revised_Specs_012000_Nov2024.pdf PDF
B08_Attachment_9_Wage_Determination.pdf PDF
B08_Attachment_8_Limitations_on_SubK_Breakout.xlsx XLSX spreadsheet
B08_Attachment_1D_Shoshone_Drawings_59-111.pdf PDF
B08_Attachment_1C_Shoshone_Drawings_15-58.pdf PDF
B08_Attachment_1E_Shoshone_Drawings_112-124.pdf PDF
Sol_140L0625R0002.pdf PDF
B08_Attachment_1A_Shoshone_Drawings_1-7.pdf PDF
B08_Attachment_4_Geotech_Report.pdf PDF
B08_Attachment_7_ACM_Report.pdf PDF
B08_Attachment_5_Clarifications.pdf PDF
B08_Attachment_6_Idaho_Lead-Based_Paint_Debris_Fact_Sheet.pdf PDF
B08_Attachment_11_SF1442_Completion_Instructions.pdf PDF
B08_Attachment_10_Past_Perf_Questionnaire.docx DOCX document
B08_Attachment_2A_Specifications.pdf PDF
Show all 37

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

P L O T

D A T E

P L O T T E D

B Y

C H K 'D

B Y

D E S

IG

N O F F

IC

E

D E S

IG

N E D

B Y

P R O J E C T

N O

D R A W N

B Y

A P P R O V E D

B Y

U N

IT

E D

S T A T E S

D E P A R T M E N T

O F

T H E

IN

T E R

IO

R B U R E A U

O F

L A N D

M A N A G E M E N T

D A T E

D E S C R

IP

T

IO

N M A R K

A P P R O V E D

D A T E

SHEET OF

:4

:0

A M

C

U s e rs a ri c o D o c u m e n ts A u to

C a d R e v it

L o c a l

F il e N W B L M D O H V A C a lf re d o ri c o .r v t

V E N T

IL

A T

IO

N D U C T W O R K

P L A N

A R E A

D

M102D

S H O S H O N E

F

IE

L D

O F F

IC

E R E P L A C E M E N T

N

F R O N G N E R

J

R O D R

IG

U E Z

N F R O N G N E R

L B Y D

F E D E R A L

ID

A H O

F A L L S

N

F R O N G N E R

B

C A R T E R

T W

IN

F A L L S

D

IS

T R

IC

T

ID

A H O

101 124

P R

O

FE

SSIONA L ENGINEER

NATHA N J. FRONGNER

STATE OF IDAHO

L I C E N S E D

18674

N STSS

186662022.07.11 18:06:04 -06'00'

O T

D A T E

P L O T T E D

B Y

C H K 'D

B Y

D E S

IG

N O F F

IC

E

D E S

IG

N E D

B Y

P R O J E C T

N O

D R A W N

B Y

A P P R O V E D

B Y

U N

IT

E D

S T A T E S

D E P A R T M E N T

O F

T H E

IN

T E R

IO

R B U R E A U

O F

L A N D

M A N A G E M E N T

D A T E

D E S C R

IP

T

IO

N M A R K

A P P R O V E D

D A T E

SHEET OF

:4

:1

A M

C

U s e rs a ri c o D o c u m e n ts A u to

C a d R e v it

L o c a l

F il e N W B L M D O H V A C a lf re d o ri c o .r v t

H V A C

C O N T R O L S

A N D

P

IP

IN

G

P L A N

M103

S H O S H O N E

F

IE

L D

O F F

IC

E R E P L A C E M E N T

N

F R O N G N E R

J

R O D R

IG

U E Z

N F R O N G N E R

L B Y D

F E D E R A L

ID

A H O

F A L L S

N

F R O N G N E R

B

C A R T E R

T W

IN

F A L L S

D

IS

T R

IC

T

ID

A H O

102 124

P R

O

FE

SSIONA L ENGINEER

NATHA N J. FRONGNER

STATE OF IDAHO

L I C E N S E D

18674

N STSS

186662022.07.11 18:07:08

O T

D A T E

P L O T T E D

B Y

C H K 'D

B Y

D E S

IG

N O F F

IC

E

D E S

IG

N E D

B Y

P R O J E C T

N O

D R A W N

B Y

A P P R O V E D

B Y

U N

IT

E D

S T A T E S

D E P A R T M E N T

O F

T H E

IN

T E R

IO

R B U R E A U

O F

L A N D

M A N A G E M E N T

D A T E

D E S C R

IP

T

IO

N M A R K

A P P R O V E D

D A T E

SHEET OF

:4

:1

A M

C

U s e rs a ri c o D o c u m e n ts A u to

C a d R e v it

L o c a l

F il e N W B L M D O H V A C a lf re d o ri c o .r v t

E N L A R G E D

M E C H A N

IC

A L

V

IE

W S

M401

S H O S H O N E

F

IE

L D

O F F

IC

E R E P L A C E M E N T

N

F R O N G N E R

J

R O D R

IG

U E Z

N F R O N G N E R

L B Y D

F E D E R A L

ID

A H O

F A L L S

N

F R O N G N E R

B

C A R T E R

T W

IN

F A L L S

D

IS

T R

IC

T

ID

A H O

103 124

P R

O

FE

SSIONA L ENGINEER

NATHA N J. FRONGNER

STATE OF IDAHO

L I C E N S E D

18674

N STSS

186662022.07.11 18:08:15

12ga - 80 lbs

10ga - 125 lbs

3/4"- 3000 lbs 5/8"- 2000 lbs 1/2"- 1250 lbs 3/8"- 680 lbs

1/4"- 270 lbs

1"x 16ga 700 lbs

1"x 18ga 420 lbs

1"x 20ga 320 lbs

1"x 22ga 260 lbs

1"x 22ga 260 lbs

11/2x11/2x16ga 11/2x11/2x1/8 11/2x11/2x3/16 2x2x1/811/2x11/2x1/4 2x2x3/16 2x2x1/4 21/2x21/2x3/16 21/2x21/2x1/4

11/2"x 16ga 1100 lbs

P L O T

D A T E

P L O T T E D

B Y

C H K 'D

B Y

D E S

IG

N O F F

IC

E

D E S

IG

N E D

B Y

P R O J E C T

N O

D R A W N

B Y

A P P R O V E D

B Y

U N

IT

E D

S T A T E S

D E P A R T M E N T

O F

T H E

IN

T E R

IO

R B U R E A U

O F

L A N D

M A N A G E M E N T

D A T E

D E S C R

IP

T

IO

N M A R K

A P P R O V E D

D A T E

SHEET OF

:4

:1

A M

C

U s e rs a ri c o D o c u m e n ts A u to

C a d R e v it

L o c a l

F il e N W B L M D O H V A C a lf re d o ri c o .r v t

H V A C

D E T A

IL

S

M501

S H O S H O N E

F

IE

L D

O F F

IC

E R E P L A C E M E N T

N

F R O N G N E R

J

R O D R

IG

U E Z

N F R O N G N E R

L B Y D

F E D E R A L

ID

A H O

F A L L S

N

F R O N G N E R

B

C A R T E R

T W

IN

F A L L S

D

IS

T R

IC

T

ID

A H O

104 124

P R

O

FE

SSIONA L ENGINEER

NATHA N J. FRONGNER

STATE OF IDAHO

L I C E N S E D

18674

N STSS

186662022.07.11 18:09:38

O T

D A T E

P L O T T E D

B Y

C H K 'D

B Y

D E S

IG

N O F F

IC

E

D E S

IG

N E D

B Y

P R O J E C T

N O

D R A W N

B Y

A P P R O V E D

B Y

U N

IT

E D

S T A T E S

D E P A R T M E N T

O F

T H E

IN

T E R

IO

R B U R E A U

O F

L A N D

M A N A G E M E N T

D A T E

D E S C R

IP

T

IO

N M A R K

A P P R O V E D

D A T E

SHEET OF

:4

:1

A M

C

U s e rs a ri c o D o c u m e n ts A u to

C a d R e v it

L o c a l

F il e N W B L M D O H V A C a lf re d o ri c o .r v t

H V A C

D E T A

IL

S

M502

S H O S H O N E

F

IE

L D

O F F

IC

E R E P L A C E M E N T

N

F R O N G N E R

J

R O D R

IG

U E Z

N F R O N G N E R

L B Y D

F E D E R A L

ID

A H O

F A L L S

N

F R O N G N E R

B

C A R T E R

T W

IN

F A L L S

D

IS

T R

IC

T

ID

A H O

105 124

P R

O

FE

SSIONA L ENGINEER

NATHA N J. FRONGNER

STATE OF IDAHO

L I C E N S E D

18674

N STSS

186662022.07.11 18:10:53

O T

D A T E

P L O T T E D

B Y

C H K 'D

B Y

D E S

IG

N O F F

IC

E

D E S

IG

N E D

B Y

P R O J E C T

N O

D R A W N

B Y

A P P R O V E D

B Y

U N

IT

E D

S T A T E S

D E P A R T M E N T

O F

T H E

IN

T E R

IO

R B U R E A U

O F

L A N D

M A N A G E M E N T

D A T E

D E S C R

IP

T

IO

N M A R K

A P P R O V E D

D A T E

SHEET OF

:4

:1

A M

C

U s e rs a ri c o D o c u m e n ts A u to

C a d R e v it

L o c a l

F il e N W B L M D O H V A C a lf re d o ri c o .r v t

H V A C

D E T A

IL

S

M503

S H O S H O N E

F

IE

L D

O F F

IC

E R E P L A C E M E N T

N

F R O N G N E R

J

R O D R

IG

U E Z

N F R O N G N E R

L B Y D

F E D E R A L

ID

A H O

F A L L S

N

F R O N G N E R

B

C A R T E R

T W

IN

F A L L S

D

IS

T R

IC

T

ID

A H O

106 124

P R

O

FE

SSIONA L ENGINEER

NATHA N J. FRONGNER

STATE OF IDAHO

L I C E N S E D

18674

N STSS

186662022.07.11 18:12:23

DUCT DETECTOR

DUCT DETECTOR

P L O T

D A T E

P L O T T E D

B Y

C H K 'D

B Y

D E S

IG

N O F F

IC

E

D E S

IG

N E D

B Y

P R O J E C T

N O

D R A W N

B Y

A P P R O V E D

B Y

U N

IT

E D

S T A T E S

D E P A R T M E N T

O F

T H E

IN

T E R

IO

R B U R E A U

O F

L A N D

M A N A G E M E N T

D A T E

D E S C R

IP

T

IO

N M A R K

A P P R O V E D

D A T E

SHEET OF

:4

:1

A M

C

U s e rs a ri c o D o c u m e n ts A u to

C a d R e v it

L o c a l

F il e N W B L M D O H V A C a lf re d o ri c o .r v t

H V A C

D E T A

IL

S

M504

S H O S H O N E

F

IE

L D

O F F

IC

E R E P L A C E M E N T

N

F R O N G N E R

J

R O D R

IG

U E Z

N F R O N G N E R

L B Y D

F E D E R A L

ID

A H O

F A L L S

N

F R O N G N E R

B

C A R T E R

T W

IN

F A L L S

D

IS

T R

IC

T

ID

A H O

107 124

P R

O

FE

SSIONA L ENGINEER

NATHA N J. FRONGNER

STATE OF IDAHO

L I C E N S E D

18674

N STSS

186662022.07.11 18:13:53

O T

D A T E

P L O T T E D

B Y

C H K 'D

B Y

D E S

IG

N O F F

IC

E

D E S

IG

N E D

B Y

P R O J E C T

N O

D R A W N

B Y

A P P R O V E D

B Y

U N

IT

E D

S T A T E S

D E P A R T M E N T

O F

T H E

IN

T E R

IO

R B U R E A U

O F

L A N D

M A N A G E M E N T

D A T E

D E S C R

IP

T

IO

N M A R K

A P P R O V E D

D A T E

SHEET OF

:4

:1

A M

C

U s e rs a ri c o D o c u m e n ts A u to

C a d R e v it

L o c a l

F il e N W B L M D O H V A C a lf re d o ri c o .r v t

H V A C

D E T A

IL

S

M505

S H O S H O N E

F

IE

L D

O F F

IC

E R E P L A C E M E N T

N

F R O N G N E R

J

R O D R

IG

U E Z

N F R O N G N E R

L B Y D

F E D E R A L

ID

A H O

F A L L S

N

F R O N G N E R

B

C A R T E R

T W

IN

F A L L S

D

IS

T R

IC

T

ID

A H O

108 124

P R

O

FE

SSIONA L ENGINEER

NATHA N J. FRONGNER

STATE OF IDAHO

L I C E N S E D

18674

N STSS

186662022.07.11 18:15:07

O T

D A T E

P L O T T E D

B Y

C H K 'D

B Y

D E S

IG

N O F F

IC

E

D E S

IG

N E D

B Y

P R O J E C T

N O

D R A W N

B Y

A P P R O V E D

B Y

U N

IT

E D

S T A T E S

D E P A R T M E N T

O F

T H E

IN

T E R

IO

R B U R E A U

O F

L A N D

M A N A G E M E N T

D A T E

D E S C R

IP

T

IO

N M A R K

A P P R O V E D

D A T E

SHEET OF

:4

:2

A M

C

U s e rs a ri c o D o c u m e n ts A u to

C a d R e v it

L o c a l

F il e N W B L M D O H V A C a lf re d o ri c o .r v t

H V A C

S C H E D U L E S

M601

S H O S H O N E

F

IE

L D

O F F

IC

E R E P L A C E M E N T

N

F R O N G N E R

J

R O D R

IG

U E Z

N F R O N G N E R

L B Y D

F E D E R A L

ID

A H O

F A L L S

N

F R O N G N E R

B

C A R T E R

T W

IN

F A L L S

D

IS

T R

IC

T

ID

A H O

109 124

P R

O

FE

SSIONA L ENGINEER

NATHA N J. FRONGNER

STATE OF IDAHO

L I C E N S E D

18674

N STSS

186662022.07.11 18:16:34

TRANSFORMER

ELECTRICAL GROUND

-GENERAL-

WALL MOUNTED BATTERY PACK EMERGENCY LIGHT

SHADING INDICATES LUMINAIRE ON LIFE SAFETY

COMBINATION MOTOR STARTER

BRANCH CIRCUIT HOME RUN TO PANELBOARD,

DESIGNATION INDICATES PANEL AND CIRCUIT

NUMBERS.

BARE-LAMP FLUORESCENT STRIP LIGHT

OCCUPANCY SENSOR

WALL MOUNTED LUMINAIRE

CONDUIT STUB DOWN (OUT OF DRAWING LIMITS)

CONDUIT STUB UP (OUT OF DRAWING LIMITS)

-GENERAL-

CONDUIT BREAK SYMBOL

LIGHTING, ONE-LINE, AND POWER CIRCUITING

CONDUIT CAP

CEILING MOUNTED FOURPLEX RECEPTACLE

FLOOR MOUNTED SPECIAL PURPOSE RECEPTACLE

CEILING MOUNTED DUPLEX RECEPTACLE

DISCONNECT SWITCH

MOTOR STARTER

FUSED DISCONNECT SWITCH

SPECIAL PURPOSE RECEPTACLE

FOURPLEX RECEPTACLE

-LIGHTING-

FLOOR MOUNTED DUPLEX RECEPTACLE

FLOOR MOUNTED FOURPLEX RECEPTACLE

FUSED SWITCH

PHOTOCELL FOR DAYLIGHTING

MOTOR

-ONE LINE SYMBOLS-

CIRCUIT BREAKER

CONTROL FUSE

TRANSFORMER

MANUAL TRANSFER SWITCH

PANELBOARD

CONDUIT CHANGE IN ELEVATION

SYMBOL DESCRIPTION

DUPLEX RECEPTACLE

GFI = GROUND FAULT CIRCUIT

INTERRUPTER

D = DEDICATED DUPLEX GROUNDED

RECEPTACLE

IG = ISOLATED GROUND

DESCRIPTIONSYMBOL

SYMBOL DESCRIPTION SYMBOL DESCRIPTION

LIGHTING, ONE-LINE, AND POWER CIRCUITING

(UNDERGROUND)

WALL MOUNTED EXIT LIGHT (WITH FACES &

DIRECTION ARROWS INDICATED IF USED)

NEW PANEL, SURFACE MOUNTED

DISTRIBUTION PANEL

T

BONDING POINT

GROUND BUS

GROUND TEST WELL

GROUNDING CONDUCTOR

CONTROL WIRING

FEEDER DESIGNATION, SEE FEEDER SCHEDULE

SPECIAL SYSTEMS SYMBOLS:

CR = CARD READER

OS = OCCUPANCY SENSOR

R = REMOTE INDICATING LIGHT

TC = TIME CLOCK

TS = TAMPER SWITCH

- ABBREVIATIONS - - ABBREVIATIONS -

(E)

(N)

(PART)

+XX

A

AC

AF

AFC

AFF

AFG

AIC

AS

AT

BFG

C

CAM

CB

CKT

CLG

CSC

ELEC

ELEV

EMERG

FA

FACP

FLR

FLUOR

G

EF

GEN

GFCI

GFI

GND

HP

HV

IC

IG

JB

K

LTG

LTS

LV

MAM

MCB

MCSW

MLO

MTD

N

NC

NEC

NF

NIC

NL

NO

P

PB

PNL

PWR

RCPT(S)

SBC

SP

SW

T

TEL

TTB

TV

TVSS

UF

UG

UNO

V

VFD

WG

WP

WSC

XFMR

EXISTING

NEW

PARTIAL CIRCUIT

MOUNTING HEIGHT IN INCHES. AFF UNO

AMP

ABOVE COUNTER TOP

AMP FRAME

ABOVE FINISHED COUNTER

ABOVE FINISHED FLOOR

ABOVE FINISHED GRADE

AMPS INTERRUPTING CAPACITY

AMPS SENSOR

AMP TRIP

BELOW FINISHED GRADE

CONDUIT

CONTROL ADDRESSABLE MODULE

MOLDED CASE CIRCUIT BREAKER

CIRCUIT

CEILING

CEILING SECURITY CAMERA

ELECTRIC

ELEVATION

EMERGENCY

FIRE ALARM

FIRE ALARM CONTROL PANEL

FLOOR

FLUORESCENT

GROUND (EQUIPMENT)

EXHAUST FAN

GENERATOR

GROUND FAULT CIRCUIT INTERRUPTER

GROUND FAULT CIRCUIT INTERRUPTER

GROUND (EQUIPMENT)

HORSEPOWER

HIGH VOLTAGE

INTERRUPTING CAPACITY

ISOLATED GROUND

JUNCTION BOX

THOUSAND

LIGHTING

LIGHTS

LOW VOLTAGE

MONITOR ADDRESSABLE MODULE

MAIN CIRCUIT BREAKER

MOLDED CASE SWITCH

MAIN LUGS ONLY

MOUNTED

NEUTRAL

NORMALLY CLOSED

NATIONAL ELECTRIC CODE

NON FUSED

NOT IN CONTRACT

NIGHT LIGHT

NORMALLY OPEN

POLE

PULL BOX

PANEL

POWER

RECEPTACLE(S)

STRANDED BARE COPPER

SPARE

SWITCH

TRANSFORMER

TELEPHONE

TELEPHONE TERMINAL BOARD

TELEVISION

TRANSIENT VOLTAGE SURGE SUPPRESSOR

UNDERFLOOR

UNDERGROUND

UNLESS NOTED OTHERWISE

VOLTAGE

VARIABLE FREQUENCY DRIVE

WIRE GUARD

WEATHERPROOF

WALL MOUNT SECURITY CAMERA

TRANSFORMER

EXIT LIGHT (WITH FACES & DIRECTION ARROWS

INDICATED IF USED)

MISC. SYSTEM COMPONENT

PAC - PHYSICAL ACCESS CONTROL

ACC - ACCESS CONTROL CONSOLE

ANN = ANNUNCIATOR

CAM = CONTROL ADDRESSABLE MODULE

FACP = FIRE ALARM CONTROL PANEL

FSD = FIRE SMOKE DAMPER

MAM = MONITOR ADDRESSABLE MODULE

TVSS = TRANSIENT VOLTAGE SURGE

SUPPRESSER

VFD = VARIABLE FREQUENCY DRIVE

LED LUMINARIES

# = BRANCH CIRCUIT NUMBER

x = SWITCH LEG IDENTIFIER

#x

SWITCH

DUAL SWITCH

METER

UPS UNINTERRUPTIBLE POWER SUPPLY

(NOTE: NOT ALL SYMBOLS SHOWN ARE USED ON THESE DRAWINGS)ELECTRICAL LEGEND

AHJ AUTHORITY HAVING JURISDICTION

PANEL

XX

J

XXX

M

-TELECOM DEVICES-

SYMBOL DESCRIPTION

X AVAILABLE FAULT CURRENT

MTS MANUAL TRANSFER SWITCH

MCM THOUSAND CIRCULAR MILS

GROUND ROD

EGB ELECTRICAL GROUND BUSBAR

NORTH ARROW

HATCHING INDICATES ITEM(S) TO BE REMOVED

MECHANICAL EQUIPMENT TAG

KEY NOTE

SHADING INDICATES EQUIPMENT

2 PORT DATA FACEPLATE (TYPICAL)

CEILING MOUNTED SPEAKER ROUTED WITH 1"

CONDUIT. Z# CORRESPONDS TO ZONE CONTROL.

VOLUME CONTROL MOUNTED AT +48 AFF. Z#

CORRESPONDS TO THE ZONE CONTROL.

HDMI CABLE PORT MOUNTED AT +72 AFF.

S

VC Z#

TV

Z#

-FIRE ALARM DEVICES-

STROBE LIGHT

COMBINATION FIRE HORN/STROBE LIGHT

SMOKE DETECTOR

X I = IONIZATION TYPE

P = PHOTOELECTRIC TYPE

T = THERMAL TYPE

DT = DUCT TYPE

FIRE ALARM CONTROL PANEL

MANUAL PULL STATION

SYMBOL DESCRIPTION

-GRAPHIC SYMBOLS-

SYMBOL DESCRIPTION

N

19543

SWITCH SYMBOL

SINGLE POLE (IF BLANK)

2 = DOUBLE POLE

3 = THREE-WAY

4 = FOUR-WAY

D = DIMMER

K = KEY OPERATED

LV = LOW VOLTAGE

TO = THERMAL OVERLOAD

WP = WEATHERPROOF

x = SMALL LETTER INDICATES LUMINARIES

CONTROLLED

x

-POWER-

DESCRIPTIONSYMBOL

-GROUNDING-

DESCRIPTIONSYMBOL

GENERAL NOTES:

1. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH LOCAL

BUILDING CODES AND THE LATEST EDITION OF THE NATIONAL

ELECTRIC CODE (NEC).

2. REFERENCE SPECIFICATIONS FOR CONSTRUCTION MATERIALS AND

INSTALLATION PROCEDURES. SPECIFICATIONS ARE A PART OF THE

CONSTRUCTION DOCUMENTS. SHOULD ANY CONFLICT ARISE

BETWEEN THE DRAWINGS AND SPECIFICATIONS, SUCH CONFLICT

SHALL BE BROUGHT TO THE ATTENTION OF THE

ARCHITECT/ENGINEER FOR RESOLUTION.

3. THESE DRAWINGS ARE DIAGRAMMATIC IN CHARACTER AND DO NOT

NECESSARILY SHOW MATERIALS FOR A COMPLETE INSTALLATION.

4. ALL PENETRATIONS THROUGH FIRE SEPARATION WALLS ARE TO BE

SEALED TO MAINTAIN SEPARATION RATING.

5. JUNCTION BOXES FOR LUMINARIES ARE NOT INDICATED HERE ON.

PROVIDE THE PROPER NUMBER OF J-BOXES TO MEET LOCAL CODE

AND NATIONAL ELECTRICAL CODE.

6. LEGEND SHOWN ABOVE IS APPLICABLE TO ALL ELECTRICAL

DRAWINGS.

SDBTC SOFT DRAWN BARE TINNED COPPER

WELDER RECEPTACLE

JUNCTION BOX MOUNTED AT 100" AFF. FOR

FUTURE SECURITY SYSTEM. WITH 1" CONDUIT

AND PULL STRING.

03:16:40 PM 07-11-2022 (-04'00' GMT)

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X

X

X

X

X

X

X X

X X

X

X X X X X X

X

OHP

OHP

OHP

OHP

OHP

OHP

OHP

OHP

OHP

OHP

OHP

OHP

OHP

OHP

OHP

OHP

OHP

OHP

OHP

OHP

OHP

OHP

OHP

ELEVATION

UG

P

U G

P

UGP

UGP

UGP

UGP

UGP

UGP

UGP

U G

P

U G

P

U G

P U

G P

UGP

U G

P U

G P

U G

P

U G

P U

G P

U G

P

G P

P

UGP

UGP

UGP

UGP

UGP

UGP

UGP

UGP

TC

TC

TC

TC

TC

TC

TC

TC

TC

TC

TC

TC

TC

TC

TC

TC

TC

UGP

UGP

UGP

UGP

UGP

UGP

UGP

UGP

UGP

UG

P

UG

P

X

X

XXX

XXXXXXXXXXXXXX

X

OHP

OHP

OH

U G

XXXXXXXXXXXXXXXX

XXXXXXXXXXXX

XXXXXXXXXXXXXXXX

XXXXXXXXXXXX

XXXXXXXXXXXXXX

XXXXXXXXXXXXX

XXXXXXXXXXXXXX

XXXXXXXXXXXXXXXX

X

X

OHPOHP

POHPOHPOHPHPOH

OHPPPOHP

OHPO

OHPOOOOOOOOOOOOO

OHP

OHP

OHP

OHO

ELEVATIONLEVATIO

UGP

UGP GPPUGPUGUGUGUUUUGUGUGUUGUGGPUUUGGGPUGGPUGUGGPPU

GPGGPUGP

TC

TC

TC

TC

TC

TC

TC

UGP

UGP

UGP

UGP

UGP

UGP

U

P U

PGP

U

UGP

UGP

UGPGP

U

UG

P

UG

GPUGUUUU

HP

X

X

X

X

X

XXXXXXXXXXXXXXXXXXXXXXXXX

XXXXX

XXXXXXXXXX

XXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXX

X

X X

X

XXXX

X

UG

P

UG

P

UG

P

UG

P

UUG

P

UGUUUG

P

UGUG

P

UG

P

UGUUG

P

UUGUGUGGGG

P

G

PPP

UUUUUUUUUUUU

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

UGP

UGP

UGP

UGP

UGP

UGP

UGP

U XX

U G

P

U G

P

U G

P U

G P

PP

UGPGP

TC

TC

TC

TC

TC

XXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXXX

U

G P

GG

P

G P

U G

P G

PPPPP

G

P G

P G

PP

G

P G

P G

P G

PPPP

G

P G

PP

G

P G

P G

PPP

G

P

GG

P

GG

P G

P G

P

TC

TC

TC

TC

HPPPOHP

OHP

OHPOHH

OHPOHOHO

U G

PP

G

UU

P

G

UU

P

GG

UU

GG

P

GG

P G

U P

G U

PP

G

U P

G

UU

G

PPPP

G

UUUU

G

PP

UU

G

PP

UU

G

PP

U

GG

P

UU

G P

U

GG

PP

G

UU

P

G

UUU

GG

PP

U

GG

P U

GG

P

U

GG

PP

GG

UU

GG

P U

GG

PP

GG

U

P

GG

UU

P

G

UUU

G P

U G

PPP

G

U G

UUU

PP

G

UUUU

PPP

G

P U

G U

P

GG

U P

GG

UU

GG

U

P

GG

P

UU

GGGG

PP

U

GGGG

PP

U

GG

PP

GG

U

PPPP

GG

UU

PPPP

GGG

U

G

UU

PP

GGGG

UU

PPP

GGGG

UU

P

GGG

U G

U

PP

G

UUUU

G

PP

UU

GG

PPPPPPP

GG

UUUUUUUU

GG

PPPP

UU

G U

P U

P G

PP

UU

G U

P U

P G

PP

UUUU

GG

PPPP

UU

GGGG

PP

UU

G U

G P

U P

GG

PP

UU

G

U P

U P

G

PP

UU

GGGG

PP

UU

G P

U P

G

PP

G

UU

P G

UU

P

GG

UUUU

PP

GG

UUU

G

P U

GG

U

G U

GG

U

G U

GG

P

UU

GGGG

PP

U

G U

GG

P

G

PP

GG

U

P

GG

U P

GG

UU

GG

P

UU

GGGG

PPPP

UU

GGGG

PPP

GG

U

P

GG

U

PP

GGGG

UUUU

PP

GGG

UUUU

U G

P

UU

G

PP

UU

G

PP

UUU

G U

P G

PPP

U

GG

P

U

GG

PP

GG

P U

GG

U

PP

GGGG

UU

PP

GGGG

UU

P

GG

UU

GG

P

UUUU

GG

PP

UUUU

GGGG

PP

UU

GGGG

PP

UU

GGGG

PP

U

G U

GG

P

UU

G

PP

GG

UU

PP

GGG

UUUUU

GG

PPPP

GG

UUUU

PP

G

P U

P U

G

UU

PP

G

P U

P U

G

UU

PP

GG

UUUU

PPPP

GG

UU

PP

G

P U

P U

G

UU

PP

G

P U

P U

G

UU

PPPP

GG

UU

PP

G P

U P

U G

UUUU

G

UU

G

PP

UU

G

PP

UU

GG

PPPP

U

G P

G U

P

GG

U

PP

GGGG

UU

P G

P

GG

U G

UU

GG

P U

GG

P

U G

PP

GG

U

PP

GGGG

UU

P

GGGGG

PP

GGGG

UUU

GG

P U

GG

P

UU

GG

PPPP

UU

GG

PP

U G

PPPP

G

UU

PPPP

GG

UUUU

PPP

G

P U

G

UUU

P

GG

U

GG

UU

GG

U P

GG

P

UU

GGGG

PP

UU

GGGG

PP

U

GG

P U

GG

PP

G P

GG

U

G U

PPPP

GG

UUUU

PPPP

GG

U

G U

G

UU

P

GGG

UU

P

GG

UU

P G

P

GG

U

PPPP

GG

UUUU

G U

P U

P G

PP

U

GG

PPPPPPP

GG

UUUUUU

GG

PPPP

UU

G

U P

U P

G

PP

UU

G

PP

UUUU

GG

PP

UU

GGGG

PP

UU

G U

G P

U P

GG

PP

UU

G

PP

UU

GGGG

P

UU

G

U P

U P

G

PPP

G

UU

PP

GG

UUUU

PP

GG

UUUUU

G P

U

GG

U

GG

P G

P U

GG

PP

U G

U

GGG

P

GG

U P

GG

U

P G

P

GG

U G

UU

G

U

GG

P G

P

UU

GGGG

PP

UU

GGG

PP

GG

U

GG

U P

GG

UUU

PP

GGGG

UUUU

U

G

PPPP

G P

U G

UUU

PPPP

GG

UUUU

PP

G

UUU

PP

GG

U

G U

P

GG

P U

GGG

PP

U

GG

P U

GG

P

U

GG

PP

G

P

GG

U G

U

PP

GG

UUUU

PPP

GG

U G

U

PP

GGGG

UU

PPP

GGGG

UU

P

G P

GG

U

G U

PPPP

GG

UUUUUU

G

U P

U P

G

PP

UU

GG

PPPPPPP

GG

UUUUUUU

GG

PPPP

UU

G

PP

UU

G

U P

U P

G

PP

UUUU

GG

PPPP

U

GGGG

PP

UU

P

GG

PP

UU

G

U P

U P

G

PP

UUU

GGGG

PP

UU

G

PPP

G

UU

P G

UU

PP

GG

UUUU

PP

GG

UUUU

GGGG

UU

GGG

P G

U G

P G

U G

U

GG

P G

P

UU

GGGG

PP

U G

U

GG

P G

PP

GG

U P

GG

U

G P

GG

U

G

UU

G U

GG

P

G P

UU

GGGG

PP

UU

GGGG

PPP

GG

U

P

GG

U

PP

GGGG

UUUU

PP

GGGG

UUUU

U G

P U

PP

UU

P

OHP

OHP

UGP

UGP

UGPGP

U

UGP

U

P U

PGP

UTILITIES LEGEND

EXISTING TELECOM

EXISTING UNDERGROUND ELECTRIC

EXISTING

GYM

EXISTING SOLAR

PHOTOVOLTAIC

INVERTER

ENCLOSURE

EXISTING

WAREHOUSE

EXISTING

SHOP

EXISTING

TRANSFORMER &

CT AND JUNCTION

CABINET ENCLOSURE

DEMOLITION SEQUENCE 1

DEMOLITION NOTES

DEMOLITION SEQUENCE 2

1. DEMOLITION SHALL BE SEQUENCED SUCH THAT EXISTING BUILDING

REMAINS FULLY OPERATIONAL DURING CONSTRUCTION OF NEW

FIELD OFFICE.

2. DEMOLITION MAY CONSIST OF THREE SEPARATE SEQUENCES AS

SHOWN OR AS APPROVED BY THE CO.

3. REMOVABLE ITEMS WITHIN EACH SEQUENCE SHALL BE DETERMINED

BY THE CONTRACTOR AND APPROVED BY GOVERNMENT.

4. COORDINATE NEW UTILITY CONNECTIONS AND ROUTING TO ENSURE

ALL SITE BUILDINGS REMAIN OPERATIONAL DURING CONSTRUCTION.

5. EXISTING UNDERGROUND POWER UTILITIES IMPACTED BY THE

PLACEMENT/CONSTRUCTION OF NEW BUILDING SHALL BE

TEMPORARILY REROUTED TO EXISTING FACILITY TO MAINTAIN

CONTINUOUS OPERATIONS.

6. SEE SHEET C-102, MASTER DEMOLITION PLAN, FOR ADDITIONAL

DEMOLITION NOTES.

1. MAINTAIN THE EXISTING SOUTHEAST ACCESS GATE AS

OPERATIONAL UNTIL DEMOLITION AND CONSTRUCTION WORK ON

SOUTHEAST ROADWAY AREA BEGINS. BEFORE DEMOLITION AND

CONSTRUCTION WORK ON SOUTHEAST ROADWAY BEGINS,

NORTHWEST GATE SHALL BE PROVIDED WITH AN ACCESS GATE

CONTROLLER AND MADE OPERATIONAL WITH TEMPORARY POWER.

AFTER NORTHWEST GATE IS MADE OPERATIONAL, DEMOLISH OR CAP

AND ABANDON IN PLACE UNDERGROUND POWER SERVICE FROM

EXISTING BUILDING TO SOUTHEAST ACCESS GATE CONTROLLER.

RETAIN SOUTHEAST ACCESS GATE CONTROLLER IN PLACE AND

RELOCATE POWER FEED TO NEW BUILDING

2. DEMOLISH EXISTING TELECOM SERVICE TO EXISTING BUILDING

AFTER NEW SERVICE HAS BEEN ESTABLISHED TO NEW BUILDING.

3. REMOVE POWER SERVICE FROM SOLAR PANEL INVERTER

ENCLOSURE TO EXISTING BUILDING AND RELOCATE TO NEW

BUILDING.

4. DEMOLISH EXISTING TRANSFORMER AND CT & JUNCTION CABINET

ENCLOSURE AND DEMOLISH OR CAP AND ABANDON IN PLACE

UNDERGROUND POWER SERVICE TO EXISTING BUILDINGS AFTER

NEW TRANSFORMER AND/OR TEMPORARY SERVICE IS PUT INTO

SERVICE TO NEW AND EXISTING BUILDINGS.

5. DEMOLISH OR CAP AND ABANDON IN PLACE POWER FEED TO

EXISTING WAREHOUSE AND SHOP AFTER NEW POWER FEED FROM

NEW TRANSFORMER HAS BEEN ACCOMPLISHED.

6. DEMOLISH ELECTRICAL EQUIPMENT AND APPARATUS IN EXISTING

BUILDING AFTER NEW BUILDING IS OPERATIONAL.

7. REMOVE EXISTING 12KW GENERATOR AND TRANSFER SWITCH / LOAD

PANEL AND REINSTALL AT NEW BUILDING DURING OFFICE

TRANSFER.

8. DEMOLISH LIGHT POLES AND FIXTURES AND DEMOLISH OR CAP AND

ABANDON IN PLACE POWER FEED TO EXISTING LIGHT POLES

FIXTURES.1

EXISTING ACCESS

GATE (SOUTHEAST)

EXISTING

TELECOMM

SERVICE

ENCLOSURE

EXISTING

BUILDING

TC

UGP

DEMOLITION SEQUENCE 3

EXISTING ACCESS

GATE (NORTHWEST)

1954303:17:06 PM 07-11-2022 (-04'00' GMT)

X X

X X

X X

OHP

OHP

OHP

OHP

OHP

OHP

OHP

OHP

OHP

OHP

OHP

OHP

OHP

OHP

OHP

OHP

OHP

OHP

OHP

OHP

OHP

OHP

OHP

UG

P

U G

P

G P

UGP

UGP

UGP

UGP

UGP

UGP

UGP

UGP

TC

TC

TC

TC

TC

TC

TC

TC

TC

TC

TC

TC

UG

P

UG

P

U G

P U

G P

U G

P U

G P

UG

P

UGP

UGP

U G

P U

G P

U G

P

UGP

UGP

UGP

UGP

UGP

U G

P U

G P

U G

P U

G P

U G

P

TC TC TC TC TC

LTP

LTP

LTP LTP LTP

LTP

LTP

LTP

LT

P

LTP

LTP

LTP

LTP LTP LTP LTP LTPLTP

LTP

LTP

LTP

LTP

LTP

LTP

LTP

LTP

LTP

LTP

LTP

LT

P

LT

P

LT

P

LT

P

LT

P

LTP

LTP

LTP

LTP

LTP

LTP

LTP

LTP

UGP UGP UGP UGP UGP UGP

TC

TC

TC

TC

TC

TC

TC

TC

TC

TC

U G

P U

G P

UG

P

UGP

LTP

LTP

LTP

LT

P

LT

P

LTP

LT

P

LT

P

LT

P

LTP

LTP

LTP

LTP

LTP

CR

CR

CR

CR

PACS

PACS

PACS

PACS

PACS

PACS

PACS

PACS

PACS

PACS

PACS PACS

PACS

PACS

PACS

PACS

PACS

PACS

PACS

PACS

PACS

PACS

PACS

PACS

PAC

S

PACS

PACS

PACS

PA

C

S

PA

C S

PA

C

S

PA

C S

PA

CS

PA

CS

PACS

COM

C O

M C

O M

C O

M C

O M

UG

P

LTPLTP

LT

P

CR

KEY NOTES

1. PROVIDE NEW SERVICE TO NEW TRANSFORMER.

2. PROVIDE NEW 300KVA TRANSFORMER WITH METERING PACKAGE AND NEW SECONDARY

CONNECTION ENCLOSURE. REROUTE POWER CONDUIT RUNS FROM EXISTING CT & JUNCTION

CABINET TO NEW SECONDARY CONNECTION ENCLOSURE.

3. PROVIDE NEW UNDERGROUND POWER FEED FROM NEW SECONDARY CONNECTION

ENCLOSURE TO NEW 400A NEMA 3R DISCONNECT WITH 400A FUSES, MOUNTED ON SIDE OF

NEW BUILDING. PROVIDE NEW POWER FEEDS FROM NEW DISCONNECT TO PANELBOARDS LP1

& LP2 IN MEP ROOM. SEE SINGLE LINE DIAGRAM ON SHEET E-603.

4. REMOVED NOTE.

5. PROVIDE NEW UNDERGROUND POWER FEED FROM NEW SECONDARY CONNECTION

ENCLOSURE TO EXISTING WAREHOUSE. FIELD LOCATE AND TIE INTO EXISTING POWER FEED,

SEE SINGLE DIAGRAM ON SHEET E-603.

6. PROVIDE NEW UNDERGROUND POWER FEED FROM NEW SECONDARY CONNECTION

ENCLOSURE TO EXISTING SHOP. FIELD LOCATE AND TIE INTO EXISTING POWER FEED, SEE

SINGLE DIAGRAM ON SHEET E-603.

7. PROVIDE NEW UNDERGROUND POWER FEED FROM EXISTING SOLAR POWER CONVERTER

INVERTER ENCLOSURE TO NEW PV SYSTEM DISCONNECT PANEL ON SIDE OF NEW BUILDING.

SEE SINGLE LINE DIAGRAM ON SHEET E-603.

8. PROVIDE #2/0 AWG BARE CU GROUND RING, WITH (4) GROUND RODS LOCATED 5FT FROM

BUILDING FOOTPRINT BURIED MINIMUM 36" BELOW FINISHED GRADE. GROUND RING SHALL

BOND WITH ELECTRICAL GROUND BUS BAR (EGB) LOCATED IN MAIN BUILDING MEP ROOM. SEEN

SINGLE LINE DIAGRAM ON SHEET E-603.

9. PROVIDE NEW UNDERGROUND 3" FEED FROM NEW BUILDING I.T./PACS ROOM TO VEHICLE

ACCESS GATE CONTROLLERS.

10. PROVIDE NEW ELECTRIC VEHICLE ACCESS GATE SYSTEM WITH SLIDE GATE OPERATOR. GATE

CONTROLLER TO HAVE BATTERY BACKUP. EACH VEHICLE GATE REQUIRES ACCESS CARD

READERS ON ENTRY AND EXIT. EACH PEDESTAL TO CONTAIN 2 CARD READERS, ONE LOCATED

LOW FOR CARS AND ONE LOCATED HIGHER FOR LARGER VEHICLES. EACH PEDESTAL TO

CONTAIN AN AUDIO/ VIDEO STATION. CONDUCTORS SHALL BE SIZED IN ACCORDANCE WITH

MANUFACTURES RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE A FULLY FUNCTIONAL

GATE OPENING SYSTEM.

11. PROVIDE TWENTY-TWO (22) NEW LED AREA LIGHTS, 25' TALL LIGHT POLE, CONTROLLED WITH

EMBEDDED WIRELESS NETWORKED CONTROLS, WITH PHOTOCELL AND DIMMING CAPABILITY.

PROVIDE UNDERGROUND CONDUIT FROM NEW BUILDING MEP ROOM. INSTALL HANDHOLES AS

NECESSARY. REFER TO DETAIL 22 ON SHEET C-505 AND PANEL SCHEDULE LP2 ON SHEET E-601.

12. PROVIDE NEW COMMUNICATION ENCLOSURE, REROUTE EXISTING COMMUNICATION CONDUIT

RUNS FROM EXISTING CT & JUNCTION CABINET ENCLOSURE TO NEW COMMUNICATION

ENCLOSURE.

13. PROVIDE NEW UNDERGROUND COMM CONDUIT FROM NEW COMMUNICATION ENCLOSURE TO

NEW BUILDING COMM ROOM. (2) 3" PVC.

14. REMOVED NOTE.

15. PROVIDE NEW UNDERGROUND COMM CONDUIT TO EXISTING SHOP. FIELD LOCATE AND TIE

INTO EXISTING COMM CONDUIT FEEDS.

16. PROVIDE NEW UNDERGROUND COMM CONDUIT TO EXISTING WAREHOUSE. FIELD LOCATE AND

TIE INTO EXISTING COMM CONDUIT FEEDS.

17. PROVIDE NEW 3' UNDERGROUND COMM CONDUIT FROM EXISTING TELCOM ENCLOSURE TO

NEW BUILDING I.T./PACS ROOM.

18. PROVIDE AND REPLACE BROKEN SOLAR PANEL. REPAIR INVERTER. PROVIDE LIGHTNING

PROTECTION FOR SOLAR ARRAY AND INVERTER CABINET PER MANUFACTURER'S

RECOMMENDTATIONS.

19. PROVIDE 3" UNDERGROUND CONDUIT AND HANDHOLE FOR FUTURE ELECTRIC VEHICLE

CHARGING AREA.

20. PROVIDE NEW UNDERGROUND FEED FROM MEP ROOM TO RELOCATED GENERATOR. SEE

SINGLE LINE DIAGRAM ON SHEET E-601 AND VIEW 2/E103 ON SHEET E-103.

UTILITIES LEGEND

TC

UGP

EXISTING TELECOM

EXISTING UNDERGROUND ELECTRIC

PROPOSED TELECOM

PROPOSED UNDERGROUND ELECTRIC

TC

UGP

EXISTING ACCESS

VEHICLE GATE

CONTROLLER

NEW

OFFICE

BLDG

NEW ACCESS

VEHICLE GATE 2

EXISTING

GYM

EXISTING SOLAR

PHOTOVOLTAIC INVERTER

ENCLOSURE

EXISTING

WAREHOUSE

EXISTING

SHOP

GENERAL NOTES

1. COORDINATE CONNECTIONS AND ROUTING WITH OTHER SITE UTILITIES.

EXISTING

TRANSFORMER &

CT AND JUNCTION

CABINET ENCLOSURE

EXISTING ACCESS

VEHICLE GATE IN

TEMPORARY USE

DURING

CONSTRUCTION

EXISTING

TELECOMM

SERVICE

ENCLOSURE

CR

PACS PROPOSED ACCESS CONTROL SYSTEM

CARD READER STATION

J HANDHOLE /JUNCTION BOX

LTP PROPOSED UNDERGROUND ELECTRIC

FOR LIGHTING

NEW ACCESS

VEHICLE GATE 1

EXISTING ACCESS

VEHICLE GATE

(CURRENTLY NOT

IN OPERATION)

RELOCATED 12KW

GENERATOR

8EXISTING BUILDING

OUTLINE

FUTURE ELECTRIC

VEHICLE CHARGING

AREA

NEW ACCESS

VEHICLE GATE 1

OPERATOR

STATION

1954303:17:19 PM 07-11-2022 (-04'00' GMT)

O T

D A T E

P L O T T E D

B Y

C H K 'D

B Y

D E S

IG

N O F F

IC

E

D E S

IG

N E D

B Y

P R O J E C T

N O

D R A W N

B Y

A P P R O V E D

B Y

U N

IT

E D

S T A T E S

D E P A R T M E N T

O F

T H E

IN

T E R

IO

R B U R E A U

O F

L A N D

M A N A G E M E N T

D A T E

D E S C R

IP

T

IO

N M A R K

A P P R O V E D

D A T E

SHEET OF

:0

:1

A M

C

U s e rs a ri c o D o c u m e n ts A u to

C a d R e v it

L o c a l

F il e N W B L M D O E L E C T a lf re d o ri c o .r v t

P O W E R

P L A N

E103

S H O S H O N E

F

IE

L D

O F F

IC

E R E P L A C E M E N T

D D

J R

L B Y D

F E D E R A L

ID

A H O

F A L L S

D D B C

T W

IN

F A L L S

D

IS

T R

IC

T

ID

A H O

114 124

1954303:17:30 PM 07-11-2022 (-04'00' GMT)

O T

D A T E

P L O T T E D

B Y

C H K 'D

B Y

D E S

IG

N O F F

IC

E

D E S

IG

N E D

B Y

P R O J E C T

N O

D R A W N

B Y

A P P R O V E D

B Y

U N

IT

E D

S T A T E S

D E P A R T M E N T

O F

T H E

IN

T E R

IO

R B U R E A U

O F

L A N D

M A N A G E M E N T

D A T E

D E S C R

IP

T

IO

N M A R K

A P P R O V E D

D A T E

SHEET OF

:0

:2

A M

C

U s e rs a ri c o D o c u m e n ts A u to

C a d R e v it

L o c a l

F il e N W B L M D O E L E C T a lf re d o ri c o .r v t

L

IG

H T

IN

G P L A N

E104

S H O S H O N E

F

IE

L D

O F F

IC

E R E P L A C E M E N T

D D

J R

L B Y D

F E D E R A L

ID

A H O

F A L L S

D D B C

T W

IN

F A L L S

D

IS

T R

IC

T

ID

A H O

115 124

1954303:17:30 PM 07-11-2022 (-04'00' GMT)

O T

D A T E

P L O T T E D

B Y

C H K 'D

B Y

D E S

IG

N O F F

IC

E

D E S

IG

N E D

B Y

P R O J E C T

N O

D R A W N

B Y

A P P R O V E D

B Y

U N

IT

E D

S T A T E S

D E P A R T M E N T

O F

T H E

IN

T E R

IO

R B U R E A U

O F

L A N D

M A N A G E M E N T

D A T E

D E S C R

IP

T

IO

N M A R K

A P P R O V E D

D A T E

SHEET OF

:0

:2

A M

C

U s e rs a ri c o D o c u m e n ts A u to

C a d R e v it

L o c a l

F il e N W B L M D O E L E C T a lf re d o ri c o .r v t

F

IR

E A L A R M

P L A N

E105

S H O S H O N E

F

IE

L D

O F F

IC

E R E P L A C E M E N T

D D

J R

L B Y D

F E D E R A L

ID

A H O

F A L L S

D D B C

T W

IN

F A L L S

D

IS

T R

IC

T

ID

A H O

116 124

1954303:17:31 PM 07-11-2022 (-04'00' GMT)

O T

D A T E

P L O T T E D

B Y

C H K 'D

B Y

D E S

IG

N O F F

IC

E

D E S

IG

N E D

B Y

P R O J E C T

N O

D R A W N

B Y

A P P R O V E D

B Y

U N

IT

E D

S T A T E S

D E P A R T M E N T

O F

T H E

IN

T E R

IO

R B U R E A U

O F

L A N D

M A N A G E M E N T

D A T E

D E S C R

IP

T

IO

N M A R K

A P P R O V E D

D A T E

SHEET OF

:0

:2

A M

C

U s e rs a ri c o D o c u m e n ts A u to

C a d R e v it

L o c a l

F il e N W B L M D O E L E C T a lf re d o ri c o .r v t

D A T A

P L A N

E106

S H O S H O N E

F

IE

L D

O F F

IC

E R E P L A C E M E N T

D D

J R

L B Y D

F E D E R A L

ID

A H O

F A L L S

D D B C

T W

IN

F A L L S

D

IS

T R

IC

T

ID

A H O

117 124

1954303:17:31 PM 07-11-2022 (-04'00' GMT)

LP1-1 LP1-1 LP1-1

L O T

D A T E

P L O T T E D

B Y

C H K 'D

B Y

D E S

IG

N O F F

IC

E

D E S

IG

N E D

B Y

P R O J E C T

N O

D R A W N

B Y

A P P R O V E D

B Y

U N

IT

E D

S T A T E S

D E P A R T M E N T

O F

T H E

IN

T E R

IO

R B U R E A U

O F

L A N D

M A N A G E M E N T

D A T E

D E S C R

IP

T

IO

N M A R K

A P P R O V E D

D A T E

SHEET OF

:0

:2

A M

C

U s e rs a ri c o D o c u m e n ts A u to

C a d R e v it

L o c a l

F il e N W B L M D O E L E C T a lf re d o ri c o .r v t

E L E C T R

IC

A L

D E T A

IL

S

E501

S H O S H O N E

F

IE

L D

O F F

IC

E R E P L A C E M E N T

D D

J R

L B Y D

F E D E R A L

ID

A H O

F A L L S

D D B C

T W

IN

F A L L S

D

IS

T R

IC

T

ID

A H O

118 124

1954303:17:32 PM 07-11-2022 (-04'00' GMT)

O T

D A T E

P L O T T E D

B Y

C H K 'D

B Y

D E S

IG

N O F F

IC

E

D E S

IG

N E D

B Y

P R O J E C T

N O

D R A W N

B Y

A P P R O V E D

B Y

U N

IT

E D

S T A T E S

D E P A R T M E N T

O F

T H E

IN

T E R

IO

R B U R E A U

O F

L A N D

M A N A G E M E N T

D A T E

D E S C R

IP

T

IO

N M A R K

A P P R O V E D

D A T E

SHEET OF

:0

:2

A M

C

U s e rs a ri c o D o c u m e n ts A u to

C a d R e v it

L o c a l

F il e N W B L M D O E L E C T a lf re d o ri c o .r v t

E L E C T R

IC

A L

D E T A

IL

S

E502

S H O S H O N E

F

IE

L D

O F F

IC

E R E P L A C E M E N T

D D

J R

L B Y D

F E D E R A L

ID

A H O

F A L L S

D D B C

T W

IN

F A L L S

D

IS

T R

IC

T

ID

A H O

119 124

1954303:17:32 PM 07-11-2022 (-04'00' GMT)

O T

D A T E

P L O T T E D

B Y

C H K 'D

B Y

D E S

IG

N O F F

IC

E

D E S

IG

N E D

B Y

P R O J E C T

N O

D R A W N

B Y

A P P R O V E D

B Y

U N

IT

E D

S T A T E S

D E P A R T M E N T

O F

T H E

IN

T E R

IO

R B U R E A U

O F

L A N D

M A N A G E M E N T

D A T E

D E S C R

IP

T

IO

N M A R K

A P P R O V E D

D A T E

SHEET OF

:0

:3

A M

C

U s e rs a ri c o D o c u m e n ts A u to

C a d R e v it

L o c a l

F il e N W B L M D O E L E C T a lf re d o ri c o .r v t

E L E C T R

IC

A L

D E T A

IL

S

E503

S H O S H O N E

F

IE

L D

O F F

IC

E R E P L A C E M E N T

D D

J R

L B Y D

F E D E R A L

ID

A H O

F A L L S

D D B C

T W

IN

F A L L S

D

IS

T R

IC

T

ID

A H O

120 124

1954303:17:33 PM 07-11-2022 (-04'00' GMT)

O T

D A T E

P L O T T E D

B Y

C H K 'D

B Y

D E S

IG

N O F F

IC

E

D E S

IG

N E D

B Y

P R O J E C T

N O

D R A W N

B Y

A P P R O V E D

B Y

U N

IT

E D

S T A T E S

D E P A R T M E N T

O F

T H E

IN

T E R

IO

R B U R E A U

O F

L A N D

M A N A G E M E N T

D A T E

D E S C R

IP

T

IO

N M A R K

A P P R O V E D

D A T E

SHEET OF

:0

:3

A M

C

U s e rs a ri c o D o c u m e n ts A u to

C a d R e v it

L o c a l

F il e N W B L M D O E L E C T a lf re d o ri c o .r v t

E L E C T R

IC

A L

D E T A

IL

S

E504

S H O S H O N E

F

IE

L D

O F F

IC

E R E P L A C E M E N T

D D

J R

L B Y D

F E D E R A L

ID

A H O

F A L L S

D D B C

T W

IN

F A L L S

D

IS

T R

IC

T

ID

A H O

121 124

1954303:17:33 PM 07-11-2022 (-04'00' GMT)

O T

D A T E

P L O T T E D

B Y

C H K 'D

B Y

D E S

IG

N O F F

IC

E

D E S

IG

N E D

B Y

P R O J E C T

N O

D R A W N

B Y

A P P R O V E D

B Y

U N

IT

E D

S T A T E S

D E P A R T M E N T

O F

T H E

IN

T E R

IO

R B U R E A U

O F

L A N D

M A N A G E M E N T

D A T E

D E S C R

IP

T

IO

N M A R K

A P P R O V E D

D A T E

SHEET OF

:0

:3

A M

C

U s e rs a ri c o D o c u m e n ts A u to

C a d R e v it

L o c a l

F il e N W B L M D O E L E C T a lf re d o ri c o .r v t

E L E C T R

IC

A L

S C H E D U L E S

E601

S H O S H O N E

F

IE

L D

O F F

IC

E R E P L A C E M E N T

D D

J R

L B Y D

F E D E R A L

ID

A H O

F A L L S

D D B C

T W

IN

F A L L S

D

IS

T R

IC

T

ID

A H O

122 124

1954303:17:44 PM 07-11-2022 (-04'00' GMT)

O T

D A T E

P L O T T E D

B Y

C H K 'D

B Y

D E S

IG

N O F F

IC

E

D E S

IG

N E D

B Y

P R O J E C T

N O

D R A W N

B Y

A P P R O V E D

B Y

U N

IT

E D

S T A T E S

D E P A R T M E N T

O F

T H E

IN

T E R

IO

R B U R E A U

O F

L A N D

M A N A G E M E N T

D A T E

D E S C R

IP

T

IO

N M A R K

A P P R O V E D

D A T E

SHEET OF

:0

:3

A M

C

U s e rs a ri c o D o c u m e n ts A u to

C a d R e v it

L o c a l

F il e N W B L M D O E L E C T a lf re d o ri c o .r v t

E L E C T R

IC

A L

S C H E D U L E S

E602

S H O S H O N E

F

IE

L D

O F F

IC

E R E P L A C E M E N T

D D

J R

L B Y D

F E D E R A L

ID

A H O

F A L L S

D D B C

T W

IN

F A L L S

D

IS

T R

IC

T

ID

A H O

123 124

1954303:17:45 PM 07-11-2022 (-04'00' GMT)

SCALE: NTS1 ELECTRICAL SINGLE LINE DIAGRAM

NOTES:

1. NEW PAD MOUNT TRANSFORMER SHALL BE OIL FILLED TYPE KNAN WITH ADVANCED

METERING PACKAGE, WITH SECONDARY GROUNDED SERVICE CONDUCTOR GROUNDED

WITH A GROUNDING ELECTRODE.

2. REFER TO SHEET E601 & E602 FOR PANEL SCHEDULES.

3. ALL CONNECTIONS TO GROUNDING BUS BARS SHALL BE MINIMUM #4 AWG CU

4. VERIFY EXISTING WAREHOUSE & SHOP TERMINATION POINTS AND ROUTING.

5. PROVIDE ADVANCED METERING AS REQUIRED BY ENERGY POLICY ACT 2005 § 103 (42

U.S.C. § 8253(e))

6. EXISTING PV METERING NOT SHOWN

NEW PAD MOUNT

TRANSFORMER

300KVA

4.5% Z

3PH 4W

208/120V12.47KV

PANELBOARD 'LP1', 3PH, 4W

120/208V, 400A BUS, 84CKT,

22KAIC

SERVICE

UTILITY POLE

RISER GN

400A

COLD

WATER

PIPE

BUILDING

STEEL

GROUND

RING/

RODS

CONCRETE

ENCASED

ELECTRODE

COMM RM

GND BAR

'TGB'

MEP ROOM GROUND BAR, 'EGB'

TO FACP

DSW-1

800A, 4W

600A FUSE

1 2

NOTE: FACP ONE-LINE DIAGRAM IS SCHEMATIC ONLY. REFER TO PLANS FOR DEVICE QUANTITIES & LOCATIONS.

ALL DEVICES SHALL COMPLY WITH ADA REQUIREMENTS. DEVICES SHALL BE LOCATED PER NFPA & ADA REQUIREMENTS. HORNS SHALL BE CAPABLE OF BEING SILENCED WHILE MAINTAINING STROBE ACTIVATION.

PHOTO-ELECTRIC

DETECTORS

THERMAL

DETECTORS

FACP

HORNS AND STROBES ON SEPARATE CIRCUITS

120VAC CONTROL

CIRCUIT, LPX-XX

1" CONDUIT TO

ANNUNCIATOR

PANEL

SCALE: NTS

FACP SINGLE LINE DIAGRAM2

E602

NOTE 1

NOTE 2

PANELBOARD 'LP2', 3PH, 4W

120/208V, 400A BUS, 84CKT,

22KAIC

400A

NOTE 2

FEEDER SCHEDULE

NUMBER DESCRIPTION

(3) 3" CONDUIT, EA. W/ (3) 300MCM & #2/0 GND

(2) 3" CONDUIT, EA. W/ (4) 350MCM & #1 GND

2" CONDUIT, W/ (3) #4/0 & #2/0 NEUTRAL

#2/0 GEC

(1) 3" CONDUIT, W/ (4) 250MCM & #4 GND

(2) 3" CONDUIT, EA. W/ (4) #4/0 & #2 GND

1-1/4" CONDUIT, W/ (4) #4 & #8 GND

PV SYSTEM

DISCONNECT

SWITCH

400A, 4W

200A FUSE

NEW 1000A

SECONDARY

CONNECTION

ENCLOSURE

EXISTING WAREHOUSE

EXISTING SHOP

NOTE 3

EXISTING

INVERTER

PANEL

TO SOLAR

ARRAY

70A

RELOCATED

KOHLER

GENERATOR

12RESVL SERIES

12 KVA, 240/120 V,

1 , 3W, 60HZ

70 A

GEN

RELOCATED KOHLER

MODEL RXT AUTOMATIC

TRANSFER SWITCH, ATS1,

2P, 3W, SOLID NEUTRAL,

WITH 12-SPACE LOAD

CENTER

100A

NOTE 2

NOTE 4

M

ADVANCED

METER

SEE NOTE 5

NOTE 1

NOTE 6

1954303:17:45 PM 07-11-2022 (-04'00' GMT)

File details come from the government source that posted it. Updated .