Attachment I - A2_HCNTRL.pdf

PDF 42 MB Posted

Attached to
P1556 10th Marines Maintenance and Operations Complex, Marine Corps Base (MCB) Camp Lejeune, North Carolina
Solicitation number
N4008525R2532
Issued by

About this file

This document is an architectural and engineering design file for a Humidity Controlled Warehouse (Building A2) at Marine Corps Base Camp Lejeune, North Carolina, part of the 10th Marines Operational Complex project. The comprehensive set of technical drawings and specifications covers multiple disciplines including architectural, structural, mechanical, plumbing, fire protection, and electrical systems for a 46,771 square foot facility designed to support marine operations.

Key design features include a single-story Type II-B construction building with concrete masonry unit (CMU) walls, standing seam metal roofing, and specialized environmental controls for humidity management. The mechanical systems include two air handling units with chilled and hot water coils, a dehumidification system, boilers, chillers, and multiple exhaust and intake fans designed to maintain precise environmental conditions. The facility will house vehicle/equipment storage bays, offices, mechanical rooms, and support spaces, with comprehensive systems to monitor temperature, humidity, air quality, and equipment performance through a building automation system. The project is being designed for the Naval Facilities Engineering Systems Command Mid-Atlantic division, with final design submittal dated March 19, 2025 and anticipated construction completion in 2025.

View the file

Other files

File Type Posted
N4008525R2532 Amendment 0009.pdf PDF
N4008525R2532 Amendment 0008.pdf PDF
1450-04A.pdf PDF
1760523 PROD - Final (Rev02).xlsx XLSX spreadsheet
Tank_PPI.pdf PDF
HP 500 9158DBCivStruct-10th Dwg.pdf PDF
1760523 P1556_ADDENDUM_GEOTECH REPORT_TEXT.pdf PDF
P1556_FINAL_TESTS AND ANALYSES.pdf PDF
P1556_FINAL_GEOTECH REPORT_APPENDICES.pdf PDF
1760523 Amendment 04_Dwgs.pdf PDF
1760523 Amendment 03_Specs.pdf PDF
1760523 Geotech Report_Addendum 3.pdf PDF
1760523 P1556_ADDENDUM_GEOTECH REPORT_FIGURES.pdf PDF
1760523 P1556_ADDENDUM_GEOTECH REPORT_APPENDICES.pdf PDF
P1556_FINAL_GEOTECH REPORT_TEXT.pdf PDF
P1556_FINAL_GEOTECH REPORT_FIGURES.pdf PDF
N4008525R2532 Amendment 0006.pdf PDF
DD_Maneuver_Area.pdf PDF
P1495 (B1337)_Drawings_Excerpt.pdf PDF
1760523 Camp-Lejeune-SCPTu-01-Footing-Settlement-and-Liquefaction-Analyses.xls XLS spreadsheet
1760523 Amendment 05_Dwgs.pdf PDF
1760523 Amendment 04_Specs.pdf PDF
Attachment J - Price Proposal Form (rev1).docx DOCX document
N4008525R2532 Amendment 0004.pdf PDF
N4008525R2532 Amendment 0003.pdf PDF
1760523 DWG Amendment 02.pdf PDF
N4008525R2532 Amendment 0002.pdf PDF
1760523 DWG Amendment 01.pdf PDF
Site Visit Log - N4008525R2532 P1556.pdf PDF
BLDG P1556 -1760523 COMBINED.pdf PDF
N4008525R2532 Amendment 0001.pdf PDF
P1556 Interior Finishes Brand Name or Equal Redacted.pdf PDF
Attachment I - B1_B1445.pdf PDF
Attachment I - A5_B1337.pdf PDF
Attachment C - Construction Experience Data Sheet.docx DOCX document
Attachment B - PIEE Vendor Access Instructions.pdf PDF
Attachment J - Price Proposal Form.docx DOCX document
Attachment I - D2_HAZ.pdf PDF
Attachment H - SPECS.pdf PDF
Attachment G - Small Business Subcontracting Plan (SBSP) Template.docx DOCX document
Attachment F - Small Business Participation Commitment Document (SBPCD).docx DOCX document
Attachment E - Historical Small Business Utilization.docx DOCX document
N4008525R2532.pdf PDF
Attachment I - D1_B1450.pdf PDF
Attachment I - C1_HP500.pdf PDF
Attachment D - Past Performance Questionnaire.docx DOCX document
Attachment A - PPI Log Template.xlsx XLSX spreadsheet
Attachment I - A4_ARTSHLTR.pdf PDF
Attachment I - A3_NMSHLTR.pdf PDF
Attachment I - A1_FLDMAINT.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SATISFACTORY TO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

D E S

IG

N A

N D

C O

N S T R U

C T

IO

N

D C

C O

R E

N A V A L S

T A T

IO

N

N O

R F O

L K V A

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

J E

U N

E

N C

F ile

P ri n t

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

M

A

P.

STCETIHCRA

FB

BERN N.C

.NEW

CERT. NO.

UTCETIHCRA

DERET

SI

G E R

N

OI

TA

RO

PR

OC

LAR

CAROLINANORTH

50679

T

T C

E

TI

HCRAD

R E

G I S

ERE

A N

I

L

ORA

N O

R

T H

C

N

D A

R

N

DE

.J UE

ER

III

C

N

NRB E

E W

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

A T

L A

N T

IC

AS INDICATED

HCNTRL

A2

APPROVED BY SOFIA SCHWARTZ

AMB DIRECTOR

MCB CAMP LEJEUNE

S p ro je c ts

\2

\2

M

ID

L A

N T

C L P

-1 th

M a ri n e s N

M E

S

IS

C o m p le x \2

D e s ig n \2

D w g s \2

A

R C

H

A H

C N

T R

L .r v t

/3

/2

:1

:2

P

M

C O

V E

R S

H E

E T

G-001

1760523

FINAL SUBMITTAL

12915152

MARCH 19, 2025

JAS JAS DJE,III

DRR/KRT

DJD

EJA

DSN

06 MAY 2025

P -1

T

H M

A R

IN

E

S O

P E

R A

T

IO

N A

L C

O M

P L

E X

HUMIDITY CONTROLLED WAREHOUSE

MARINE CORPS BASE CAMP LEJEUNE

P-1556 10TH MARINES OPERATIONAL COMPLEX

NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND

MID-ATLANTIC

DESIGN AND CONSTRUCTION

FACILITIES ENGINEERING AND ACQUISITION DIVISION

NORFOLK, VIRGINIA

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

R

MCB CAMP LEJEUNE

ATLANTIC OCEAN

ATLANTIC OCEAN

NEW

R

IVER

P-1556 SITE

GENERAL PROJECT NOTES GOVERNING REGULATIONS

BUILDING CODE:

UNIFIED FACILITIES CRITERIA (UFC) 1-200-01 (01 SEP 2022, W/ CHANGE 3, 26 FEB 2024) UNIFIED FACILITIES CRITERIA (UFC) 1-200-02 (01 DEC. 2020, W/CHANGE 02, 01 JUN 2022) UNIFIED FACILITIES CRITERIA (UFC) 3-110-03 (01 MAY 2012, W/CHANGE 5, 12 JUN 2020)

ACCESSIBILITY CODE:

UNIFORM ACCESSIBILITY STANDARDS (UFAS)

AMERICANS WITH DISABILITIES ACT (ADA)

ACCESSIBILITY GUIDELINES FOR BUILDINGS AND FACILITIES (ADAAG)

MECHANICAL CODE:

INTERNATIONAL MECHANICAL CODE (IMC) 2021

ELECTRICAL CODE:

NFPA 70, NATIONAL ELECTRIC CODE (2023)

PLUMBING CODE:

INTERNATIONAL PLUMBING CODE (IPC) 2021

FIRE PREVENTION & LIFE SAFETY CODE:

UNIFIED FACILITIES CRITERIA (UFC) 3-600-01 (15 DEC. 2016, W/CHANGE 6, 06 MAY 2021)

NFPA 101, LIFE SAFETY CODE (2024)

1. WHERE EXISTING CONSTRUCTION IS DAMAGED BY CONSTRUCTION REQUIRED BY THESE

DOCUMENTS. REPAIR THE DAMAGED ITEM(S) WITH MATERIALS TO MATCH THE ADJACENT

MATERIAL, TEXTURE AND COLOR.

2. FIELD VERIFY EXISTING DIMENSIONS, PRIOR TO ORDERING MATERIALS OR BEGINNING

DEMOLITION.

3. ALL ITEMS NOT SHOWING AS "EXISTING" MUST BE PROVIDED AND INSTALLED UNDER THE

REQUIREMENTS OF THIS CONTRACT.

4. COORDINATE LAY DOWN AREA WITH THE CONTRACTING OFFICER PRIOR TO THE

PRECONSTRUCTION MEETING. THE ALLOWABLE AREA SIZE MUST BE ESTABLISHED BY THE

CONTRACTING OFFICER.

5. MANUFACTURER'S TRADE NAMES LISTED ARE NOT INTENDED TO BE PROPRIETARY.

PRODUCTS OF OTHER MANUFACTURERS WILL BE ACCEPTABLE PROVIDED THEY MATCH THE

COLOR, FINISHES, TEXTURES AND PATTERNS OF THE MANUFACTURER LISTED, AND MEET THE

TECHNICAL REQUIREMENTS OF THE SPECIFICATIONS.

6. OBSERVE AND MAINTAIN BUILDING AND COMPOUND SECURITY REQUIREMENTS AS DIRECTED

BY THE CONTRACTING OFFICER.

7. CONSTRUCTION WILL BE ACCOMPLISHED IN AND AROUND AREAS WHICH WILL REMAIN

OPERATIONAL. AVOID INTERFERENCE WITH THE OPERATIONAL WORK ROUTINE.

8. ALL SUBMITTALS REQUIRED BY THESE DRAWINGS OR SPECIFICATIONS MUST BE SUBMITTED

TO THE CONTRACTING OFFICER FOR APPROVAL PRIOR TO COMMENCEMENT OF RELATED

WORK.

B1450

B1445

B1337

NEW PARKING

B1

D1

D2

CONTROLLED

HUMID

ITY

W

AREHOUSE

A2

FIELD M

AIN

T.

SHOP

A1

A4

A5

A3-3

A3-3

PHASE 2

PHASE 1

A3

A3

SATISFACTORY TO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

D E S

IG

N A

N D

C O

N S T R U

C T

IO

N

D C

C O

R E

N A V A L S

T A T

IO

N

N O

R F O

L K V A

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

J E

U N

E

N C n t

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

M

A

P.

STCETIHCRA

FB

BERN N.C

.NEW

CERT. NO.

UTCETIHCRA

DERET

SI

G E R

N

OI

TA

RO

PR

OC

LAR

CAROLINANORTH

50679

T

T C

E

TI

HCRAD

R E

G I S

ERE

A N

I

L

ORA

N O

R

T H

C

N

D A

R

N

DE

.J UE

ER

III

C

N

NRB E

E W

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

A T

L A

N T

IC

AS INDICATED

HCNTRL

A2

APPROVED BY SOFIA SCHWARTZ

AMB DIRECTOR

MCB CAMP LEJEUNE

S p ro je c ts

\2

\2

M

ID

L A

N T

C L P

-1 th

M a ri n e s N

M E

S

IS

C o m p le x \2

D e s ig n \2

D w g s \2

A

R C

H

A H

C N

T R

L .r v t

/3

/2

:1

:2

P

M L O

C A

T

IO

N M

A P

S A

N D

I N

D E

X O

F D

R A

W

IN

G S

G-002

1760523

FINAL SUBMITTAL

12915153

MARCH 19, 2025

JAS JAS DJE,III

DRR/KRT

DJD

EJA

DSN

06 MAY 2025

P -1

T

H M

A R

IN

E

S O

P E

R A

T

IO

N A

L C

O M

P L

E X

ARCHITECT

MBF ARCHITECTS, P.A.

317-C POLLOCK STREET

NEW BERN, NC 28560

CIVIL

STANTEC

801 JONES FRANKLIN ROAD, SUITE 300

RALEIGH NC 27606

LANDSCAPE

STANTEC

229 PEACHTREE STREET NE, SUITE 1900

ATLANTA GA 30303

GEOTECHNICAL

ECS SOUTHEAST, LLP

6714 NETHERLANDS DRIVE

WILMINGTON, NC 28405

LIFE SAFETY

JENSEN HUGHES

4445 CORPORATION LANE, SUITE 211

VIRGINIA BEACH, VA 23455

STRUCTURAL

KAYDOS-DANIELS ENGINEERS, PLLC

400-201 WEST MORGAN STREET

RALEIGH, NC 27603

COMPREHENSIVE INTERIOR DESIGN

WITHIN INTERIOR DESIGN, INC.

1008 GRANBY STREET

NORFOLK, VA 23510

FIRE ALARM /FIRE PROTECTION

JENSEN HUGHES

4445 CORPORATION LANE, SUITE 211

VIRGINIA BEACH, VA 23455

PLUMBING / MECHANICAL / ELECTRICAL

CRENSHAW CONSULTING ENGINEERS

3516 BUSH STREET, SUITE 200

RALEIGH, NC 27609

REGIONAL MAP

VICINITY MAP

SITE MAP

PROJECT LOCATION

N

N

N

TELECOMMUNICATIONS

CRENSHAW CONSULTING ENGINEERS

3516 BUSH STREET, SUITE 200

RALEIGH, NC 27609

LIGHTNING PROTECTION

CRENSHAW CONSULTING ENGINEERS

3516 BUSH STREET, SUITE 200

RALEIGH, NC 27609

AUDIOVISUAL

THORBURN ASSOCIATES, INCORPORATED

2500 GATEWAY CENTRE BLVD., SUITE 800

MORRISVILLE, NC 27560

DESIGN TEAM INDEX OF DRAWINGS

BUILDING LOCATION AND PHASING MAP

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

D E S

IG

N A

N D

C O

N S T R U

C T

IO

N

D C

C O

R E

N A V A L S

T A T

IO

N

N O

R F O

L K V A

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

J E

U N

E

N C n t

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

M

A

P.

STCETIHCRA

FB

BERN N.C

.NEW

CERT. NO.

UTCETIHCRA

DERET

SI

G E R

N

OI

TA

RO

PR

OC

LAR

CAROLINANORTH

50679

T

T C

E

TI

HCRAD

R E

G I S

ERE

A N

I

L

ORA

N O

R

T H

C

N

D A

R

N

DE

.J UE

ER

III

C

N

NRB E

E W

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

A T

L A

N T

IC

AS INDICATED

HCNTRL

A2

APPROVED BY SOFIA SCHWARTZ

AMB DIRECTOR

MCB CAMP LEJEUNE

S p ro je c ts

\2

\2

M

ID

L A

N T

C L P

-1 th

M a ri n e s N

M E

S

IS

C o m p le x \2

D e s ig n \2

D w g s \2

A

R C

H

A H

C N

T R

L .r v t

/3

/2

:1

:2

P

M

IN

D

E X

O F

D R

A W

IN

G

S

G-003

1760523

FINAL SUBMITTAL

12915154

MARCH 19, 2025

JAS JAS DJE,III

DRR/KRT

DJD

EJA

DSN

06 MAY 2025

P -1

T

H M

A R

IN

E

S O

P E

R A

T

IO

N A

L C

O M

P L

E X

INDEX OF DRAWINGS

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

X

Y

FIRE EXTINGUISHER BRACKET (4A:80B:C)

X = REQUIRED EGRESS CAPACITY (PERSONS)

Y = PROVIDED EGRESS CAPACITY (PERSONS)

ROOM AREA (SF)

OCCUPANT FACTOR (SF/PERSON)

NUMBER OF OCCUPANTS (PERSONS)

SMOKE PARTITION

1-HR FIRE BARRIER

TRAVEL PATH AND DISTANCE

COMMON PATH OF TRAVEL

KNOX BOX

FIRE ALARM CONTROL PANEL

TD = XXFT

CP = XXFT

LIFE SAFETY LEGEND

1,000

XXXXX

XXXX

XXXX

FACP

K

APPLICABLE BUILDING CODES

USE GROUP/OCCUPANCY

S-1 STORAGE (IBC 311.2 & LSC 6.1.13) - ORDINARY HAZARD (LSC 42.1.5)

FOR IBC, BUILDING IS A S-1 OCCUPANCY.

FOR LSC, BUILDING IS A STORAGE OCCUPANCY.

FACILITIES USED FOR PARKING OR STORAGE OF MOTOR VEHCILES MUST COMPLY WITH NFPA 88A (UFC 3-600-01 4-47.1.1).

FIRE PROTECTION SYSTEMS

WET PIPE SPRINKLER SYSTEMS

ADDRESSABLE FIRE ALARM SYSTEM

CONSTRUCTION TYPE

FLOOR LEVEL

REQUIRED EXIT

CAPACITY

AVAILABLE EXIT

CAPACITY

NUMBER OF EXITS

REQUIRED

NUMBER OF EXITS

PROVIDED

FIRST FLOOR 32 1,700 2 9

BUILDING AREA & HEIGHT:

BASED ON SPRINKLERED GROUP S-1 ALLOWABLE PROVIDED

ALLOWABLE AREA (IBC TABLE 506.2): 70,000-SF 46,467-SF

ALLOWABLE STORIES (IBC TABLE 504.4): 1-STORY* 1-STORY

ALLOWABLE HEIGHT (IBC TABLE 504.3): 75-FT EAVES: 22-FT

PEAK: 33.93-FT

*LIMITED TO A SINGLE STORY TO ALLOW FOR THE INCREASE IN ALLOWABLE

AREA FOR A SINGLE-STORY BUILDING PER IBC TABLE 506.2

TYPE II-B

EXTERIOR WALLS

EXTERIOR FIRE EXPOSURE BASED ON SEPARATION DISTANCE (TYPE II-B)

FIRE SEPARATION DISTANCE

< 5 FT

> 5 FT AND < 10 FT

> 10 FT

GROUP S-1

2 - HOUR

1 - HOUR

0 - HOUR

INTERIOR FINISH CLASSIFICATION LIMITS

LIMITS (BASED ON STORAGE OCCUPANCY WITH REDUCTION FOR SPRINKLERS) REQUIRED PROVIDED

EXIT (TABLE A10.2.2.) MINIMUM CLASS C MINIMUM CLASS C

EXIST ACCESS CORRIDORS (TABLE A10.2.2.) MINIMUM CLASS C MINIMUM CLASS C

OTHER SPACES (TABLE A10.2.2) MINIMUM CLASS C MINIMUM CLASS C

FLOOR FINISH MINIMUM 0.1 W/CM2 MINIMUM 0.1 W/CM2

OCCUPANT LOADS

OCCUPANT LOADS (LSC TABLE 7.3.1.2)

STORAGE USE (IN STORAGE OCCUPANCY) MAXIMUM PROBABLE

BUSINESS 150 SF/PERSON

MEP SPACE 500 SF/PERSON

TRAVEL DISTANCE (LSC TABLE A.7.6)

COMMON PATH OF TRAVEL (STORAGE): 100 FT

TOTAL TRAVEL DISTANCE (ENCLOSED PARKING GARAGE LSC TABLE 42.8.6.1): 200 FT

DEAD END CORRIDOR (STORAGE): 100 FT

CAPACITY OF EXITS (LSC TABLE 7.3.3.1)

LEVEL COMPONENTS (WIDTH/PERSON) 0.2 IN/PERSON

NUMBER OF EXITS (LCS 7.4)

2 FOR OCCUPANT LOAD ≤ 500, 3 FOR OCCUPANT LOAD > 500 AND ≤ 1,000.

FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS

(IBC TABLE 601, TYPE II-B CONSTRUCTION)

REQUIRED PROVIDED

PRIMARY STRUCTRUAL FRAME, INCL. COLUMNS, GIRDERS & TRUSSES 0-HOUR 0-HOUR

PRIMARY STRUCTURAL FRAME SUPPORTING A ROOF ONLY 0-HOUR 0-HOUR

BEARING WALLS, INTERIOR & EXTERIOR 0-HOUR 0-HOUR

FLOOR CONSTRUCTION 0-HOUR 0-HOUR

ROOF CONSTRUCTION (SECONDARY MEMBERS ONLY) 0-HOUR 0-HOUR

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

IBC INTERNATIONAL BUILDING CODE 2021

UFC 1-200-01 DOD BUILDING CODE, 24 FEBRUARY 2023

UFC 3-520-01 INTERIOR ELECTRICAL SYSTEMS, 12 APRIL 2021

UFC 3-600-01 FIRE PROTECTION ENGINEERING FOR FACILITIES, 6 MAY 2021

UFC 4-440-01 WAREHOUSES AND STROAGE FACILITIES, 1 APRIL 2019

NFPA 10 PORTABLE FIRE EXTINGUISHER 2022

NFPA 13 INSTALLATION OF SPRINKLER SYSTEMS 2022

NFPA 24 INSTALLATION OF PRIVATE FIRE SERVICE MAINS AND THEIR APPURTENANCES 2022

NFPA 70 NATIONAL ELECTRICAL CODE 2023

NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE 2022

NFPA 88A PARKING STRUCTURES 2023

NFPA 90A INSTALLATION OF AIR-CONDITIONING AND VENTILATING SYSTEM 2024

NFPA 101 LIFE SAFETY CODE (LSC) 2024

THERE IS A DISTANCE OF AT LEAST 40-FT BETWEEN BUILDING A2 AND ANY OTHER STRUCTURES ON ALL SIDES. THIS PROVIDES A FIRE SEPARATION DISTANCE OF AT LEAST 30-FT FROM THE ADJACENT BUILDINGS TO AN IMAGIANRY LOT LINE AND AT LEAST 10-FT FROM THE IMAGINARY LOTE LINE TO BUILDING A2; THEREFORE, THERE IS NO FIRE RESISTANCE RATING REQUIRED ON THE EXTERIOR WALLS BASED ON THE FIRE SEPARATION DISTANCE.

INTERIOR FIRE RESISTANCE RATING REQUIREMENTS

ROOM

SPRINKLER VALVE ROOM

REQUIRED SEPARATION

1-HOUR (NFPA 24 6.2.9(6))

ADDITIONAL LIFE SAFETY CRITERIA

MEANS OF EGRESS MUST BE ILLUMINATED IN ACCORDANCE WITH LSC 7.8 (LSC 42.2.8.1). ARTIFICIAL LIGHTING IS REQUIRED AT LOCATIONS AND

TIMES NECESSARY TO MAINTAIN ADEQUATE ILLUMINATION (LSC 7.8.1.2.1).

EMERGENCY LIGHTING SYSTEMS MUST BE PROVIDED IN ACCORDANCE WITH LSC 7.9 (LSC 42.2.9).

MEANS OF EGRESS MUST BE PROVIDED WITH SIGNS IN ACCORDANCE WITH LSC 7.10 AND UFC 3-600-01 2-5.2 (LSC 42.2.10). SIGNS MUST HAVE LETTERING ON AN OPAQUE BACKGROUND. INTERNALLY ILLUMINATED SIGNS MUST BE LIGHT EMITTING DIODE (LED) TYPE, ELECTROLUMINESCENCE (LEC), OR COLD CATHODE TYPE. INCANDESCENT FIXTURES ARE NOT PERMITTED. RADIOLUMINOUS EXIT SIGNS ARE

NOT PERMITTED (UFC 3-600-01 10-2.1).

FIRE EXTINGUISHERS ARE NOT REQUIRED IN STORAGE OCCUPANCIES (LSC 42.3.5 & UFC 3-600-01 9-17.1).

PROVIDED

0 - HOUR

PROVIDED

1-HOUR

AREA

OFFICES

OCCUPANCY/USE APPROX.

AREA (SF)

OCCUPANT LOAD

FACTOR

(SF/PERSON)

OCCUPANT

LOAD

(PERSONS)

STORAGE / BUSINESS 807 5150

VEHICLE STORAGE BAY STORAGE / STORAGE 42,881 24MAX

MEP SPACES STORAGE / MEP 1,468 3500

45,156TOTAL 32-

PARKING GARAGE SEPARATION SMOKE PARTITION (NFPA 88A 5.3.5) SMOKE PARTITION

SATISFACTORY TO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

D E S

IG

N A

N D

C O

N S T R U

C T

IO

N

D C

C O

R E

N A V A L S

T A T

IO

N

N O

R F O

L K V A

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

J E

U N

E

N C n t

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

A T

L A

N T

IC

AS INDICATED

HCNTRL

A2

APPROVED BY SOFIA SCHWARTZ

AMB DIRECTOR

MCB CAMP LEJEUNE

C U s e rs \a e lb o g h d a d y \D o c u m e n ts \2

F

IR

E

A

H

C N

T R

L a e lb o g h d a d y .r v t

/2

/2

:0

:4

P

M L

IF

E S

A F

E T

Y G

E N

E R

A L

N O

T E

S A

N D

L E

G E

N D

GI001

1760523

FINAL DESIGN SUBMITTAL

12915155

MARCH 19, 2025

APF AHE KEC

DRR/KRT

DSN

EJA

DSN

P -1

T

H M

A R

IN

E

S O

P E

R A

T

IO

N A

L C

O M

P L

E X

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

Lic. No. 044409

AARON P FREIDC

O M M O

N W

EAL

THOF

V

IR

G

IN

IA

P R O F

E

SSIONAL EN

G

IN

E E

06 MAY 2025

N

0 40' 80'

BUILDING A1

R

IS

E R

FM

C P

FD

C

FH

FH

FH

FH

FH

FH

FD

E

BUILDING A2

R

IS

ER

FA

C P

FD

C

FD

E

IP

L

-F

T

IP

L

-F

T

NMESIS COMPOUND CODE COMPLIANCE SITE PLAN

A1 SCALE: 1" = 40'-0"

NOTES:

FACP - FIRE ALARM CONTROL PANEL

FAL - FIRE ACCESS LANE (W - WIDTH)

FMCP - FIRE ALARM/MASS NOTIFICATION CONTROL PANEL

FDC - FIRE DEPARTMENT CONNECTION

FDE - FIRE DEPARTMENT ENTRANCE

FH - FIRE HYDRANT

HL - HOSE LAY DISTANCE

IPL - IMAGINARY PROPERTY LINE

RISER - SPRINKLER RISER

EGRESS DISCHARGE PATH

PIV - POST INDICATING VALVE (NOT REQUIRED): CAMP LEJEUNE FIRE

DEPARTMENT PREFERS THAT INCOMING FIRE SERVICES ARE

PROTECTED IN ACCORDANCE WITH NFPA 24 6.2.9(6); THEREFORE,

INDICATING CONTROL VALVES ARE LOCATED ON THE SPRINKLER

RISERS IN FIRE-RATED ROOMS ACCESSIBLE FROM THE EXTERIOR

AND POST INDICATING VALVES ARE NOT REQUIRED.

30'

10'

30'

10'

FAL

W

>20 -F

T

FAL

W

>20 -F

T

71-FT

63-FT

FA

L W

>20-FT

HL=200-FT

HL=224-FT

HL=94-FT

HL=106-FT

HL=168-FT

HL=143-FT

TYPICAL FUTURE

NMESIS SHELTER

TYPICAL NMESIS SHELTER

SATISFACTORY TO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

D E S

IG

N A

N D

C O

N S T R U

C T

IO

N

D C

C O

R E

N A V A L S

T A T

IO

N

N O

R F O

L K V A

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

J E

U N

E

N C n t

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

A T

L A

N T

IC

AS INDICATED

HCNTRL

A2

APPROVED BY SOFIA SCHWARTZ

AMB DIRECTOR

MCB CAMP LEJEUNE

C U s e rs \a e lb o g h d a d y \D o c u m e n ts \2

F

IR

E

A

H

C N

T R

L a e lb o g h d a d y .r v t

/2

/2

:0

:4

P

M

N M

E S

IS

C

O M

P O

U N

D C

O D

E C

O M

P L

IA

N C

E S

IT

E

P L A

N

GI002

1760523

FINAL DESIGN SUBMITTAL

12915156

MARCH 19, 2025

APF AHE KEC

DRR/KRT

DSN

EJA

DSN

P -1

T

H M

A R

IN

E

S O

P E

R A

T

IO

N A

L C

O M

P L

E X

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

Lic. No. 044409

AARON P FREIDC

O M M O

N W

EAL

THOF

V

IR

G

IN

IA

P R O F

E

SSIONAL EN

G

IN

E E

A

C P

K

34567891011

A

C

D

E

F

B

1.12.110.9

E.9

D.9

A.1

COLD MECH

106B

ELECT

COMM

SPRINKLER

UNISEX

UNISEX

OFFICE

OFFICE

BULLPEN

VEHICLE/EQUIPMENT

STORAGE BAYS

41,852

MAX

TD = 153 FT

CP = 52 FT

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

JL

TV

TD = 141 FT

HOT MECH

106A

GENERAL SHEET NOTES:

1.

2.

3.

4.

5.

6.

FOR LIFE SAFETY LEGEND, SEE SHEET GI001.

APPLY MARKINGS TO FIRE-RATED BARRIERS INDICATING ITS RATING IN ACCORDANCE WITH IBC SECTION 703.5.

FIRESTOP PENETRATIONS AND JOINTS TO MAINTAIN THE INTEGRITY OF THE FIRE-RATED CONSTRUCTION. FIRE-

RESISTANCE-RATING OF WALLS, FLOORS, CEILINGS, AND SHAFTS MUST BE MAINTAINED.

PENETRATIONS AND JOINTS MUST BE PROVIDED WITH UL LISTED FIRESTOP SYSTEMS.

THE RATINGS OF FIRESTOP SYSTEMS MUST BE GREATER THAN OR EQUAL TO THE RATING OF THE BARRIER.

UL ASSEMBLIES AND MATERIAL PRODUCT DATA SHEETS FOR FIRESTOPPING SYSTEMS MUST BE SUBMITTED AND APPROVED BEFORE ANY FIRESTOPPING IS INSTALLED. REFER TO THE PROJECT SPECIFICATIONS FOR

ADDITIONAL REQUIREMENTS AND INFORMATION.

SATISFACTORY TO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

D E S

IG

N A

N D

C O

N S T R U

C T

IO

N

D C

C O

R E

N A V A L S

T A T

IO

N

N O

R F O

L K V A

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

J E

U N

E

N C n t

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

A T

L A

N T

IC

AS INDICATED

HCNTRL

A2

APPROVED BY SOFIA SCHWARTZ

AMB DIRECTOR

MCB CAMP LEJEUNE

C U s e rs \a e lb o g h d a d y \D o c u m e n ts \2

F

IR

E

A

H

C N

T R

L a e lb o g h d a d y .r v t

/2

/2

:0

:4

P

M

L

IF

E S

A F

E T

Y F

L O

O R

P L A

N

H U

M

ID

IT

Y

C O

N T

R O

L L E

D W

A R

E H

O U

S E

GI101

1760523

FINAL DESIGN SUBMITTAL

12915157

MARCH 19, 2025

APF AHE KEC

DRR/KRT

DSN

EJA

DSN

P -1

T

H M

A R

IN

E

S O

P E

R A

T

IO

N A

L C

O M

P L

E X

N

GRAPHIC SCALE: 1/16"=1'-0"

16' 0 8' 16' 32'

SCALE: 1/16" = 1'-0"

A3

HUMIDITY CONTROLLED WAREHOUSE LIFE SAFETY FLOOR PLAN

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

Lic. No. 044409

AARON P FREIDC

O M M O

N W

EAL

THOF

V

IR

G

IN

IA

P R O F

E

SSIONAL EN

G

IN

E E

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

YS

TE

M S

C O

M M

AN

D

DRAWFORM REVISION: 25 AUGUST 2020

DE

SI

GN

A

ND

C

ON

ST

RU

CT

IO

N (D C) C

OR

E

NA

VA

L

ST

AT

IO

N

- N

OR

FO

LK

, V A

M

AR

IN

E

C O

R

PS

B

AS

E C

AM

P

LE

JE

U N

E, N

C

Fi le

Pa th

P rin t D at e:

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

S

YS

TE

M

S C

O M

M

AN

D

M

ID

AT

LA

N

TI

C

AS INDICATED

HCNTRL

A2

APPROVED BY SOFIA SCHWARTZ

AMB DIRECTOR

MCB CAMP LEJEUNE

C :\U se rs

\h en ry .K

AY

D

O S-

D

AN

IE

LS

\D oc um en ts \S

TR

U

C T_

_A 2_

H C

N

TR

L_ ho ne w el l.r vt 4/

/2

:4

0:

A M

C O

VE

R

S H

EE

T

S-001

1760523

FINAL SUBMITTAL

12915158

MARCH 19, 2025

BCC SAM LGG

DRR/KRT

NBJ

EJA

DSN

06 MAY 2025

P-

0T H

M

AR

IN

ES

O

PE

R

AT

IO

N

AL

C

O M

PL

EX

SHEET INDEX

SHEET NO SHEET TITLE

S-001 COVER SHEET

S-002 STRUCTURAL NOTES

S-003 STRUCTURAL NOTES

S-101 FOUNDATION PLAN

S-102 ROOF FRAMING PLAN

S-501 GENERAL CONSTRUCTION DETAILS

S-502 GENERAL CONSTRUCTION DETAILS

S-511 STRUCTURAL SECTIONS

S-512 STRUCTURAL SECTIONS

DESIGN CRITERIA

1. BUILDING CODES..............................2021 IBC "INTERNATIONAL BUILDING CODE"

UFC 1-200-01, CHANGE 2, 12 JUN 2023 "GENERAL BUILDING REQUIREMENTS"

UFC 3-301-01, CHANGE 1, 02 OCT 2023 "STRUCTURAL ENGINEERING"

UFC 4-010-01, CHANGE 2, 30 JUL 2022 "MINIMUM ANTI-TERRORISM

STANDARDS FOR BUILDINGS"

2. BUILDING RISK CATEGORY........................................................................................... II

3. SUPERIMPOSED DEAD LOADS:

a) ROOF...................................................................................................... 20 PSF

4. DESIGN LIVE LOADS:

a) ROOF...................................................................................................... 20 PSF

b) FLOOR.................................................................................................. 100 PSF

c) MECHANICAL/ELECTRICAL ROOMS...................................................125 PSF

d) VEHICLE BAY (AXLE LOAD) ...................................................................... 16K

5. SNOW:

a) GROUND SNOW LOAD ........................................................................ 10 PSF

b) FLAT ROOF SNOW LOAD..................................................................... 10 PSF

c) SNOW EXPOSURE FACTOR, Ce ............................................................... 1.0

d) IMPORTANCE FACTOR, Is ........................................................................ 1.0

e) THERMAL FACTOR, Ct ............................................................................... 1.0

6. WIND

a) ULTIMATE WIND SPEED ................................................................. 144 MPH

b) NOMINAL WIND SPEED.................................................................... 112 MPH

c) WIND EXPOSURE CATEGORY..................................................................... B

d) INTERNAL PRESSURE COEFFICIENT .................................................... 0.18

e) ROOF COMPONENTS AND CLADDING .......... SEE TABLE ON SHEET S001

f) WALL COMPONENTS AND CLADDING .......... SEE TABLE ON SHEET S001

g) WIND BASE SHEAR (ULTIMATE).................................. Vx = 101K, Vy = 203K

7. SEISMIC:

a) SITE CLASS .................................................................................................. D

b) IMPORTANCE FACTOR, Ie ........................................................................ 1.0

c) MAPPED SPECTRAL RESPONSE ACCELERATION, Ss ................... 0.115 G

d) ONE SECOND PERIOD SPECTRAL RESPONSE COEFFICIENT, ..... 0.055 G

e) SHORT PERIOD SPECTRAL RESPONSE COEFFICIENT, SDS ........ 0.123 G

f) ONE SEC PERIOD SPECTRAL RESPONSE COEFFICIENT, SD1...... 0.088 G

g) SEISMIC RESPONSE COEFFICIENT, Cs ............................................... 0.041

h) RESPONSE MODIFICATION FACTOR, R

i) SEISMIC DESIGN CATEGORY .................................................................... B

j) BASIC SEISMIC FORCE RESISTING SYSTEM ........................... STEEL NOT

SPECIFICALLY DETAILED FOR SEISMIC

k) ANALYSIS PROCEDURE ............................ EQUIVALENT LATERAL FORCE

l) SEISMIC BASE SHEAR ........................................................... Vx = Vy = 109K

8. RAIN:

a) RAIN INTENSITY, i ............................................................................ 4.25 in/hr

A A

ZONE 45 5

3 2 3

3 2 3

ZO

NE

WALLS

ROOF

COMPONENTS & CLADDING PRESSURE (PSF)

SHOP DRAWINGS/SUBMITTALS:ABBREVIATIONS:

ParallelPAR.

CONT Continuous

Double Degree Demolish, Demolition

Centered Counter Sink

Depressed

Existing

Electric, Electrical

Each Face

Elevation Edge Nail

Equipment

Expansion Joint

Drawing

Diameter Diagonal Dimension

Drag Truss

Face of Steel (Studs)

Face Of

Far Side

Face of Masonry

Field Nail Floor, Flooring

Foundation

Face of Concrete

Existing

Exterior Expansion

Each Way

Finish, Finished

Finished Floor Finish Grade

Floor Joist

Future

Header Hanger

Height

Gusset

Heating/Ventilation/ Air Conditioning

Hold Down

Horizontal High Point

Grade Beam

Grade, Grading Glued Laminated Girder Truss

Footing

Each Side

Laminated Length, Angle

Include

Inside Diameter

Information

Interior Insulated

FTG

INT.

JST

L

LAM

JT. Joint Joist

HT

H.P.

HORIZ

H.V.A.C

IN

I.D.

INCL

INFO

INS

Inch

GA

GD

G.B.

FUT.

GLB

G.T.

HD

HGR

HDR

GUSS.

Gauge

Equal

F.J.

FLR

F.N.

FND

F.S.

F.O.

F.O.C.

F.O.S.

F.O.M.

FT. Feet

EQ.

EQPT.

EXP.

E.W.

F.F.

F.G.

FIN

EXT.

EXIST'G

E.S.

DO

DWG

DWL

D.T.

E.F.

E.J.

E.N.

ELV

ELEC

EA.

Dowel

Each

CSK

DBL

DEG

DEP

DEM

CTR'D

DIA

DIM

DIAG

Ditto

Pounds per Cubic Foot

Plate, Property Line

Precast Concrete

Pounds per Square Foot Pounds per Square Inch

Revision, Revised

Pressure Treated

R.,RAD.

Return

Rafters Roof

Required Reinforcement Reference

RFT.

RF.

REF.

RET.

REQ.

REINF.

REV.

Plywood Panel

Penetration

Radius

PLY.

PNL.

P.T.

P.S.I.

P.S.F.

PENT.

P.C.C.

P.C.F.

PL.

American Concrete Institute

Air Conditioning Anchor Bolt

Bottom Bottom of Footing

Above Finished Floor

American Society for Testing Materials

American Plywood Institute

Between

Blocking

Boundry Nail

Adjacent

Architect

Alternate Aluminum

Concrete Masonry Unit

Control Joint / Ceiling Joist

Connection Construction

Ceiling

Cast-in-Place

Concrete

Channel

ARCH.

C.J.

CLG

COL

CLR

CONC

CMU

C.I.P.

CONST

CONN

C

Column

Clear

A.S.T.M.

B.N.

BM

BLW.

BETWN.

BLK.

BOTT

B.O.F.

BLKG

Beam

Below

Block

A/C A.B.

A.C.I.

AL.

ADJ.

ALT.

A.P.A.

A.F.F.

Long Leg Horizontal

Mount, Mounted, Mounting

Manufacture, Manufacturer

Long Leg Vertical

Opposite Hand, Overhead Outside Diameter

MaximumMAX

Number Nominal

Opening

On Center Not To Scale

Not In Contract

Near Side

North

O.D.

O.C.

N.T.S.

OPNG

O.H.

NOM

N.S.

N.I.C.

NO.

N.

Minimum

Medium

Metal

Mezzanine

Miscellaneous Masonry Opening

Machine Bolt

Mechanical

MFR

MIN

MISC

M.O.

MTL

MT.

MECH

M.B.

MEZZ

MED

Long Pound

Live Load

Louver Masonry

Low Point

L.L.H.

L.P.

LVR

MAS

L.L.V.

L.L.

LG

LB

(E)

P PlateL

Unless Otherwise Noted Unless Noted Otherwise

Welded Wire Mesh Welded Wire Fabric WeightWT.

W.W.M.

W.W.F.

Vapor Barrier Vertical

Without

West Wood

Water Proof Working Point

With

W/O W.P.

W.PT.

W.

WD.

V.B.

U.O.N.

VERT.

U.N.O.

W/

Toe Nail

Typical Tube Steel Top of Wall

Top of Beam

Top of Steel Top of Parapet Top of Footing Top of Concrete

T.O.S.

T.S.

TYP.

T.O.W

T.N.

T.O.B.

T.O.P.

T.O.F.

T.O.C.

Sheet Metal Screw Specification(s)

Thick, Thickness

R.T. Roof Truss

S.S. Stainless Steel

Steel Structural

Stiffener Standard

Tongue & Groove Top & Bottom Symmetrical Suspended

Top of Curb

SYM

THK

T.C.

T&G T&B

STL.

STD.

STRUCT

STIFF.

SUSP.

South Schedule Section

Similar Sheet

Square

Separation

SHT.

SIM.

SPEC.

S.M.S.

SQ.

SEC.

SEP.

SCHED.

S.

Room

Rough Sawn Rough Opening

R.S.

R.O.

RM.

International Building CodeIBC Seismic Lateral Resisting SystemSLRS

GalvanizedGAL

Grade BeamGB

Masonry Control JointMCJ

Pre-Engineered Metal BuildingPEMB.

Powder Acuated FastenersP.A.F.

S-XXX

A1

A1

S-XXX

A1

S-XXX

GRID LINES - CENTER LINE

DETAIL NO.

ELEVATION NO.

SECTION NO.

SECTION

ELEVATION

DETAIL BUBBLE

GRID LINES - F.O. STUD/WALL

GRID NO.

SHEET NO. WHERE

SECTION IS SHOWN

SHEET NO. WHERE

ELEVATION IS SHOWN

SHEET NO. WHERE

DETAIL IS SHOWN

DESIGN BASIS: SYMBOLS:

RO

OF

COMPONENTS & CLADDING NEW DESIGN WIND PRESSURE (ULTIMATE)

ZONE

EFFECTIVE

WIND

AREA

(+) PRESSURE

(PSF)

(-) PRESSURE

(PSF)

1 10 36 -64

1 20 31 -57

1 50 25 -47

1 100 20 -40

2 10 -88

2 20 -79

2 50 -66

2 100 -57

3 10

3 20

3 50

3 100

4 10 48 -52

4 20 46 -50

4 50 48 -47

4 100 41 -45

4 500 36 -40

5 10 -64

5 20 -60

5 50 -54

5 100 -50

5 500 -40

W

AL

LS

-88

-79

-66

-57

ZO

NE

REFERENCE SPECIFICATIONS FOR

SPECIAL INSPECTION REQUIREMENTS

1.

2.

3.

4.

5.

SEE SPECIFICATIONS AND DEFERRED SUBMITTAL REQUIREMENTS ON SHEET

S-002 FOR REQUIRED SHOP DRAWING AND SUBMITTAL REQUIRMENTS TO BE

PROVIDED TO THE CONTRACTING OFFICER FOR REVIEW AND COMMENT.

STEEL REINFORCING LISTS AND QUANTITIES AND LENGTH OF ALL MATERIALS

ARE THE RESPONSIBILITY OF THE CONTRACTOR TO ASSURE COMPLIANCE

WITH THE PLANS. THE ENGINEER WILL NOT REVIEW THESE ITEMS.

REVIEW OF SHOP DRAWINGS IS FOR THE PURPOSE OF GENERAL COMPLIANCE

WITH THE CONTRACT DOCUMENTS. ALL ERRORS IN DETAILING, FABRICATION,

AND CORRECT FITTING OF ALL STRUCTURAL MEMBERS INCLUDING

COORDINATION WITH OTHER TRADES ARE THE RESPONSIBILITY OF THE

CONTRACTOR. SHOP DRAWING SUBMITTAL REVIEW DOES NOT CONSTITUTE

CHANGE ORDERS. ANY PROPOSED CHANGES MUST BE SUBMITTED IN A

LETTER OR DETAIL FOR APPROVAL.

SHOP DRAWINGS MUST BE SUBMITTED AT LEAST TWO WEEKS PRIOR TO THE

SCHEDULED FABRICATION DATE.

REPRODUCTION OF THESE STRUCTURAL DRAWINGS IS PROHIBITED FOR THE

PURPOSE OF PREPARING SHOP DRAWINGS. SUBCONTRACTOR/FABRICATOR

MUST PROVIDE INDEPENDENTLY CREATED DRAWINGS BASED ON THE

INFORMATION SHOWN IN THE CONTRACT DOCUMENTS.

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

YS

TE

M S

C O

M M

AN

D

DRAWFORM REVISION: 25 AUGUST 2020

DE

SI

GN

A

ND

C

ON

ST

RU

CT

IO

N (D C) C

OR

E

NA

VA

L

ST

AT

IO

N

- N

OR

FO

LK

, V A

M

AR

IN

E

C O

R

PS

B

AS

E C

AM

P

LE

JE

U N

E, N

C

P rin t D at e:

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

S

YS

TE

M

S C

O M

M

AN

D

M

ID

AT

LA

N

TI

C

AS INDICATED

HCNTRL

A2

APPROVED BY SOFIA SCHWARTZ

AMB DIRECTOR

MCB CAMP LEJEUNE

C :\U se rs

\h en ry .K

AY

D

O S-

D

AN

IE

LS

\D oc um en ts \S

TR

U

C T_

_A 2_

H C

N

TR

L_ ho ne w el l.r vt 4/

/2

:4

0:

A M

ST

R

U C

TU

R

AL

N

O

TE

S

S-002

1760523

FINAL SUBMITTAL

12915159

MARCH 19, 2025

BCC SAM LGG

DRR/KRT

NBJ

EJA

DSN

06 MAY 2025

P-

0T H

M

AR

IN

ES

O

PE

R

AT

IO

N

AL

C

O M

PL

EX

STRUCTURAL NOTES

1.0.1

1.0.2

1.0.3

1.0.4

1.0.5

1.0.6

1.0.8

1.0.9

1.0.10

1.0.11

1.0.12

1.0.13

3.2.1

3.2.2

3.2.3

3.2.4

3.2.5

3.2.6

3.3.4

3.3.1

3.3.2

3.3.3

3.2.7

3.2.8

3.2.9

3.2.10

3.2.11

3.3.5

3.3.6

3.3.7

3.3.8

3.3.9

3.1.9

3.1.10

3.1.11

3.01.0 GENERAL NOTES: 3.3 MECHANICAL ANCHORS IN HARDENED

CONCRETE AND MASONRY

(EXPANSION ANCHORS):

CONCRETE:

REINFORCING STEEL:3.1

3.2 ADHESIVE, ANCHOR RODS AND REBAR

IN HARDENED CONCRETE (EPOXY

ANCHORS):

A.

B.

ADHESIVE ANCHOR INSTALLATIONS MUST COMPLY WITH MANUFACTURER'S

WRITTEN INSTRUCTIONS AND SPECIFICATIONS, INLCUDING ICC-ES REPORTS

DUST MUST BE BLOWN FROM THE HOLE WITH COMPRESSED AIR TO

ENSURESURFACE. ADDITIONALLY, THE HOLE MUST BE BRUSHED WITH A NYLON

BRUSH THEN BLOWN AGAIN WITH COMPRESSED AIR.

ADHESIVE MUST ONLY BE APPLIED TO DRY SURFACES.

BASE MATERIAL TEMPERATURE MUST BE 40°F OR ABOVE AT TIME OF

INSTALLATION. FOR BEST RESULTS, MATERIAL SHOULD BE 70°F-80°F.

WHEN INSTALLING EPOXY ANCHORS INTO MASONRY, ANCHORS MUST BE

INSTALLED IN SOLID GROUTED CELLS ONLY.

CHEMICAL ANCHOR SYSTEMS:

CONCRETE: USE ONLY ADHESIVE ANCHOR SYSTEMS THAT HAVE BEEN

ISSUED AN ICC-ES REPORT IN ACCORDANCE WITH PROVISIONS OF OF

ICC-ES AC308. ANCHOR SYSTEM SHOULD BE APPROVED FOR USE IN

CRACKED CONCRETE AND SEISMIC DESIGN CATEGORIES A-F PER

SECTION 2.0 OF THE ICC-ES EVALUATION SERVICES REPORT. ANCHOR

SYSTEM MUST BE INSTALLED PER REQUIREMENTS OF THE ICC-ES

EVALUATION SERVICES REPORT FOR SPECIFIC ANCHOR, AND AS

REQUIRED BY THE MANUFACTURER.

GROUT-FILLED MASONRY UNITS: USE ONLY ADHESIVE

ANCHORSYSTEMS THAT HAVE BEEN ISSUED AN ICC-ES REPORT

INACCORDANCE WITH PROVISIONS OF ISS-ES AC58. ANCHORSYSTEMS

MUST BE INSTALLED PER REQUIREMENTS OF ICC-ESEVALUATION

SERVICES REPORT FOR THE SPECIFIC ANCHOR,AND AS REQUIRED BY

THE MANUFACTURER.

ANCHOR RODS:

RODS MUST BE ASTM A36 THREADED RODS WITH ASTM A563 GRADE A NUTS

AND ANSI B18.22.1 TYPE A WASHERS, UNLESS OTHERWISE NOTED. ANCHORS

DESIGNATED AS ASTM A193 GRADE B7 THREADED RODS MUST USE ASTM A563

GRADE DH HEAVY HEX NUTS AND ASTM F436 WASHERS.

REINFORCEMENT BARS: ASTM A615 GRADE 60 STEEL.

REMOVE GREASE, OIL, RUST AND OTHER LAITANCE FROM RODS AND DOWELS

PRIOR TO INSTALLATION.

SPECIAL INSPECTION REQUIREMENTS MUST BE DICTATED BY SECTION 4.0 OF

THE ICC-ES EVALUATION SERVICES REPORT. SPECIAL INSPECTION MUST

VERIFY ANCHOR TYPE, ANCHOR DIMENSIONS, CONCRETE TYPE, CONCRETE

COMPRESSIVE STRENGTH, HOLE DIMENSIONS, ANCHOR SPACINGS, EDGE

DISTANCES, SLAB THICKNESS, ANCHOR EMBEDMENT, AND TIGHTENING

TORQUE.

CONTRACTOR'S OPTION TO USE OTHER MANUFACTURER'S PRODUCTS ONLY

WITH PRIOR APPROVAL OF THE ENGINEER & CONTRACTING OFFICER. SUBMIT

MANUFACTURER'S LITERATURE AND PRODUCT INSTALLATION FOR REVIEW.

A.

B.

ANCHORS TO BE INSTALLED IN HOLES DRILLED WITH CARBIDE-TIPPED DRILL

BITS. ANCHORS TO BE INSTALLED PER MANUFACTURER'S WRITTEN

INSTRUCTIONS.

WHEN INSTALLING DRILLED EXPANSION ANCHORS IN EXISTING REINFORCED

CONCRETE, USE CARE AND CAUTION TO AVOID CUTTING OR DAMAGING THE

EXISTING REINFORCEMENT.

MAINTAIN A MINIMUM CLEARANCE OF 25 mm[1"] BETWEEN THE REINFORCEMENT

AND THE DRILLED EXPANSION ANCHORS. EXPANSION ANCHORS MUST NOT BE

USED AT CONCRETE CURBS.

EXPANSION ANCHOR SYSTEMS:

CONCRETE: USE ONLY EXPANSION ANCHOR SYSTEMS THAT HAVE BEEN

ISSUED AN ICC-ES REPORT IN ACCORDANCE WITH THE PROVISIONS OF

ICC-ES AC193. ANCHOR SYSTEMS SHOULD BE APPROVED FOR USE WITH

CRACKED CONCRETE AND SEISMIC DESIGN CATEGORIES A-F PER

SECTION 2.0 OF THE ICC EVALUATIONS SERVICES REPORT. ANCHOR

SYSTEM MUST BE INSTALLED PER THE REQUIREMENTS OF THE ICC-ES

EVALUATION SERVICES REPORT FOR THE SPECIFIC ANCHOR, AND AS

REQUIRED BY THE MANUFACTURER.

MASONRY: USE ONLY EXPANSION ANCHOR SYSTEMS THAT HAVE BEEN

ISSUED AN ICC-ES REPORT IN ACCORDANCE WITH THE PROVISIONS OF

ICC-ES AC01. ANCHOR SYSTEMS SHOULD BE APPROVED FOR SEISMIC

USE DETAILED IN THE CONDITIONS OF USE LISTED IN THE ICC-ES

EVALUATION SERVICES REPORT. ANCHOR SYSTEM MUST BE INSTALLED

PER THE REQUIREMENTS OF THE ICC-ES EVALUATION SERVICES

REPORT FOR THE SPECIFIC ANCHOR, AND AS REQUIRED BY THE

MANUFACTURER.

UNDERCUT ANCHOR SYSTEMS:

CONCRETE: USE ONLY UNDERCUT ANCHOR SYSTEMS THAT HAVE BEEN ISSUED

AN ICC-ES REPORT IN ACCORDANCE WITH THE PROVISIONS OF ICC-ES AC193.

ANCHOR SYSTEMS SHOULD BE APPROVED FOR USE IN CRACKED CONCRETE

AND SEISMIC DESIGN CATEGORIES A-F PER SECTION 2.0 OF THE ICC

EVALUATIONS SERVICES REPORT. ANCHOR SYSTEM MUST BE INSTALLED

PER THE REQUIREMENTS OF THE ICC-ES EVALUATION SERVICES REPORT

FOR SPECIFIC ANCHOR, AND AS REQUIRED BY THE MANUFACTURER.

WHERE THE MANUFACTURER'S INSTALLATION INSTRUCTIONS OR APPLICABLE

ICC-ES EVALUATION SERVICES REPORT CALL FOR THE APPLICATION OF AN

INSTALLATION TORQUE, THE SPECIFIED TORQUE MUST BE APPLIED WITH

CALIBRATED TORQUE WRENCH. THE SPECIFIED INSTALLATION TORQUE MUST

NOT BE EXCEEDED.

ANCHORS ARE TYPICALLY AVAILABLE IN ELECTRO-GALVANIZED CARBON STEEL,

HOT DIPPED GALVANIZED CARBON STEEL, AND STAINLESS STEEL. USE OF

ELECTRO-GALVANIZED CARBON STEEL ANCHORS IS TYPICALLY LIMITED TO DRY,

INTERIOR LOCATIONS, UNLESS OTHERWISE NOTED. STAINLESS STEEL OR HOT-

DIPPED GALVANIZED ANCHORS ARE GENERALLY. SUITABLE FOR APPLICATIONS

EXPOSED TO EXTERIOR WEATHER CONDITIONS. FINAL AUTHORITY ON TYPE OF

ANCHOR COATING UTILIZED RESTS WITH THE STRUCTURAL ENGINEER OF

RECORD & CONTRACTING OFFICER AND MUST BE APPROVED BY SUCH.

EXPANSION ANCHORS FOR NON-VIBRATION ISOLATED MECHANICAL EQUIPMENT

RATED OVER 10HP ARE NOT PERMITTED BY ASCE 7-10 SECTION 13.6.5.5.

ANCHORS INSTALLED IN OVERHEAD CONDITIONS FOR NON- VIBRATION

ISOLATED EQUIPMENT WITH RECIPROCATING OR ROTATING MECHANISMS MUST

BE UNDERCUT ANCHORS.

THE SPECIAL INSPECTOR MUST BE ON THE JOBSITE CONTINUOUSLY DURING

ANCHOR INSTALLATIONS, UNLESS OTHERWISE NOTED IN ICC-ES ESR, TO VERIFY

ANCHOR TYPE, ANCHOR DIMENSIONS, CONCRETE TYPE, CONCRETE

COMPRESSIVE STRENGTH, HOLE DIMENSIONS ANCHOR SPACINGS, EDGE

DISTANCES, SLAB THICKNESS, ANCHOR EMBEDMENT, AND TIGHTENING

TORQUE.

A.

B.

C.

D.

E.

F.

G.

A.

B.

C.

D.

THE PROJECT SPECIFICATIONS (A BOOK OF SPECIFICATIONS WHEN PROVIDED)

ARE A PART OF THE CONTRACT DOCUMENTS. IF THERE IS A DISCREPANCY

FOUND BETWEEN THE SPECIFICATIONS AND THE DRAWINGS, SPECIFICATIONS

TAKE PRECEDENCE, HOWEVER THE MATTER MUST BE PROMPTLY SUBMITTED

TO THE CONTRACTING OFFICER FOR CLARIFICATION. WORK PERFORMED BY

THE CONTRACTOR WITHOUT SUCH A CLARIFICATION MUST BE AT

CONTRACTOR'S OWN RISK AND EXPENSE.

EXAMINE THE STRUCTURAL DRAWINGS AND THE SPECIFICATIONS AND NOTIFY

THE ENGINEER & CONTRACTING OFFICER OF DISCREPANCIES IN ELEVATIONS,

DIMENSIONS, AND SITE CONDITIONS INCLUDING ERRORS BEFORE PROCEEDING

WITH WORK. OMISSIONS AND CONFLICTS BETWEEN THE VARIOUS ELEMENTS

OF THE DRAWINGS (AND SPECIFICATIONS) MUST BE RESOLVED IN WRITING

WITH THE ENGINEER/ARCHITECT & CONTRACTING OFFICER PRIOR TO START OF

WORK.

THE DRAWINGS (AND SPECIFICATIONS) REPRESENT THE COMPLETED

STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION.

PROVIDE ALL MEASURES AND MEANS NECESSARY TO PROTECT PERSONS AND

THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES MUST INCLUDE,

BUT NOT BE LIMITED TO BRACING, SHORING, ETC. OBSERVATION VISITS BY THE

ARCHITECT OR ENGINEER DOES NOT INCLUDE REVIEW OF THESE MEASURES.

TYPICAL DETAILS MUST BE USED WHENEVER APPLICABLE WHETHER

SPECIFICALLY REFERENCED OR NOT.

DRAWINGS MUST NOT BE SCALED FOR CONSTRUCTION PURPOSES.

PIPES OR DUCTS MUST NOT BE PLACED IN STRUCTURAL MEMBERS UNLESS

SPECIFICALLY DETAILED OR APPROVED BY THE ENGINEER & CONTRACTING

OFFICER.

REFER TO ARCHITECTURAL DRAWINGS FOR THE FOLLOWING:

SIZE AND LOCATION OF DOOR AND WINDOW OPENINGS, UNLESS

OTHERWISE NOTED.

SIZE AND LOCATION OF INTERIOR AND EXTERIOR NON-BEARING

PARTITIONS.

SIZE AND LOCATION OF CURBS, FLOOR DRAINS, SLOPES, DEPRESSED

AREAS, CHANGES IN LEVEL, RAMPS, CHAMFERS, GROOVES, INSERTS,

ETC., EXCEPT AS SHOWN.

SIZE AND LOCATION OF FLOOR AND ROOF OPENINGS, EXCEPT AS

SHOWN.

FLOOR AND ROOF FINISHES.

STAIR FRAMING AND DETAILS, EXCEPT AS SHOWN.

DIMENSIONS NOT SHOWN ON STRUCTURAL DRAWINGS.

REFER TO MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR THE

FOLLOWING:

PIPE RUNS, SLEEVES, HANGERS, TRENCHES, SLAB OPENINGS, ETC.,

EXCEPT AS SHOWN OR NOTED.

ELECTRICAL CONDUITS, BOXES, OUTLETS.

CONCRETE INSERTS FOR ELECTRICAL, MECHANICAL AND PLUMBING

FIXTURES.

SIZE AND LOCATION OF MACHINE AND EQUIPMENT BASES, ANCHOR

BOLTS, ETC.

ASTM REFERENCES ARE FROM THE LATEST ISSUE AND LATEST REVISION,

UNLESS OTHERWISE NOTED.

INVESTIGATE THE SITE DURING CLEARING AND EXCAVATION FOR UNSUITABLE

CONDITIONS, UNCONSOLIDATED AND UNDOCUMENTED FILLS, BURIED

STRUCTURES, UTILITIES, ETC., AND IMMEDIATELY NOTIFY THE

ARCHITECT/ENGINEER & CONTRACTING OFFICER OF SITE CONDITIONS NOT

REFLECTED ON THE DRAWINGS OR DIFFERENT FROM MAXIMUM OR MINIMUM

DIMENSIONS INDICATED, INCLUDING CONFLICT IN GRADES, ADVERSE SOIL

CONDITIONS, GROUNDWATER PRESENT, DEEPENED FOOTINGS, UNCOVERED

AND UNEXPECTED UTILITY LINES, ETC.

CONSTRUCTION MATERIALS, IF PLACED ON STRUCTURAL MEMBERS, MUST BE

SPREAD OUT SUCH THAT THE LOADING DOES NOT EXCEED THE DESIGN LIVE

LOADS. PROVIDE SHORING AND BRACING WHERE CONSTRUCTION LOADING

EXCEEDS THE DESIGN STRENGTH OF THE STRUCTURAL MEMBERS OR THE

STRUCTURAL STRENGTH HAS NOT BEEN ATTAINED OR THE STRUCTURE IS NOT

COMPLETE.

DETERMINE THE LOCATION OF UTILITY SERVICES IN AREAS TO BE EXCAVATED

BEFORE BEGINNING EXCAVATION. EXERCISE EXTREME CAUTION IN

EXCAVATING AND TRENCHING. DAMAGE CAUSED AS A RESULT OF FAILING TO

EXACTLY LOCATE AND PRESERVE EXISTING UNDERGROUND UTILITIES IS THE

RESPONSIBILITY OF THE CONTRACTOR.

STRUCTURAL DRAWINGS TO BE USED IN CONJUNCTION WITH ARCHITECTURAL

DRAWINGS BY: MBF ARCHITECTS

SLAB ON GRADE

FOOTINGS & ALL OTHER CONCRETE

MIN. f'c

4,000 psi 3,000 psi

SLAB ON GRADE REINFORCEMENT MUST BE POSITIONED AT MID-DEPTH.

SHOP DRAWINGS FOR SIZE AND LAYOUT OF REINFORCING REBARS ARE

REQUIRED WHEN NOTED IN THE LIST OF REQUIRED SHOP DRAWINGS.

3.0.11 PROVIDE CONSTRUCTION OR CONTROL JOINTS IN SLAB ON GRADE AS SHOWN

ON PLANS UNLESS SPECIFIED OTHERWISE. LOCATION OF JOINTS NOT

SPECIFICALLY INDICATED MUST BE REVIEWED BY THE STRUCTURAL ENGINEER &

CONTRACTING OFFICER PRIOR TO PLACING REINFORCING STEEL.

DRY PACK MUST BE ONE PART CEMENT AND 2 3/4 PARTS SAND WITH JUST

ENOUGH WATER TO HYDRATE CEMENT AND FORM A BALL SHOWING MOISTURE

ON THE SURFACE WHEN SQUEEZED. IT MUST BE RAMMED IN TIGHT TO MAXIMUM

DENSITY ATTAINABLE, AND MUST BE FROM A PRODUCT THAT SPECIFIES A

MINIMUM STRENGTH AT 28 DAYS OF 5000 psi.

NON-SHRINK GROUT MUST BE FROM A PRODUCT THAT SPECIFIES A MINIMUM

COMPRESSIVE STRENGTH AT 28 DAYS OF 7,000 psi PER ASTM C109. GROUTING

OF BASE PLATES PRIOR TO PLUMBING OF COLUMN IS NOT PERMITTED.

PROJECTING CORNERS OF SLABS, BEAMS, WALLS, COLUMNS, ETC., MUST BE

FORMED WITH A 3/4" CHAMFER OR TOOLED EDGE, UNLESS OTHERWISE NOTED.

CONCRETE WHICH DURING THE LIFE OF THE STRUCTURE MUST BE SUBJECT TO

FREEZING TEMPERATURES WHILE WET, MUST HAVE A WATER CEMENT RATIO

NOT EXCEEDING 0.45 BY WEIGHT AND MUST CONTAIN ENTRAINED AIR PER ACI

613. SUCH CONCRETE MUST INCLUDE EXTERIOR SLABS, PERIMETER

FOUNDATIONS, EXTERIOR CURBS, ETC.

3.0.12

3.0.13

3.0.14

3.0.15

3.0.1 CEMENT MUST CONFORM TO ASTM C150, TYPE II / V

AGGREGATES FOR NORMAL WEIGHT CONCRETE MUST CONFORM TO ASTM C33,

1 1/2" MAXIMUM SIZE.

ADMIXTURES MUST NOT BE USED WITHOUT PRIOR APPROVAL OF THE ENGINEER

& CONTRACTING OFFICER. ADMIXTURES USED TO INCREASE THE WORKABILITY

OF THE CONCRETE MUST NOT REDUCE THE STRENGTH OF CONCRETE. FLY ASH

(POZZOLAN) IF PERMITED BY SPECIFICATIONS MUST NOT EXCEED 25% FOR SLAB

ON GRADE AND 25% FOR OTHER CONCRETE.

THE MIX DESIGN, INCLUDING PROPORTIONS OF MATERIALS FOR A ONE YARD

BATCH, MUST BE SUBMITTED TO THE ENGINEER OF RECORD & CONTRACTING

OFFICER FOR REVIEW PRIOR TO ORDERING CONCRETE.

READY-MIX CONCRETE MUST BE MIXED AND DELIVERED IN ACCORDANCE WITH

ASTM C94.

REINFORCING BARS AND INSERTS MUST BE SECURED IN PLACE PRIOR TO

PLACING CONCRETE.

CONDUITS EMBEDDED HORIZONTALLY IN THE SLAB MUST HAVE AN OUTSIDE

DIAMETER NO GREATER THAN 1/3 THE THICKNESS OF THE SLAB. CONDUIT MUST

NOT BE EMBEDDED IN A SLAB THAT IS LESS THAN 3 1/2" THICK. EXCEPT FOR

LOCAL OFFSETS, MIN. CLEAR DISTANCE BETWEEN CONDUITS MUST BE 6".

NON-STRUCTURAL STEEL MEMBERS EMBEDDED IN CONCRETE MUST BE

GALVANIZED OR PAINTED. DAMAGED GALVANIZED AREAS MUST BE REPAIRED

PRIOR TO EMBEDMENT.

CONCRETE MUST HAVE A MAXIMUM DRY DENSITY OF 150 pcf.

MINIMUM CONCRETE COMPRESSIVE STRENGTHS AT 28 DAYS.

3.0.2

3.0.3

3.0.4

3.0.5

3.0.6

3.0.7

3.0.8

3.0.9

3.0.10

CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED

TO EARTH:.............................................................................. 3"

CONCRETE EXPOSED TO EARTH OR WEATHER:

NO.6 THROUGH NO.18 BAR ................................... 2"

NO.5 BAR, W31 OR D31 WIRE, AND SMALLER ....1 1/2"

CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT

WITH GROUND:

SLABS, WALLS, JOISTS:

NO.14 AND NO.18 BAR .............................................1 1/2"

NO.11 BAR AND SMALLER ...................................... 3/4"

3.1.1 DETAILING, FABRICATION AND ERECTION OF REINFORCING BARS MUST BE IN

ACCORDANCE WITH ACI MANUAL OF STANDARD PRACTICE FOR DETAILING

REINFORCED CONCRETE STRUCTURES, ACI 315-LATEST ADOPTED EDITION.

REINFORCING MUST BE ADEQUATELY SUPPORTED TO PREVENT DISPLACEMENT

BY CONCRETE PLACEMENT OR WORKERS.

REINFORCING BARS EXCEPT BARS TO BE WELDED MUST CONFORM TO THE

"STANDARD SPECIFICATION FOR DEFORMED BILLET STEEL BARS FOR

CONCRETE REINFORCEMENT", ASTM A615 GRADE 60. BARS TO BE WELDED

MUST CONFORM TO ASTM A706.

WELDING OF REINFORCING BARS TO BE IN ACCORDANCE WITH "STRUCTURAL

WELDING CODE-REINFORCING STEEL", AWS D1.4. REINFORCING STEEL TO BE

WELDED MUST HAVE A MAXIMUM CARBON EQUIVALENT (CE) OF 0.75. SPECIAL

INSPECTION IS REQUIRED. TESTING IS REQUIRED FOR WELDS THICKER THAN

5/16".

WHERE CONTINUOUS BARS ARE CALLED OUT IN FOOTINGS, SPLICES MAY BE

USED. WHERE BARS ARE SHOWN SPLICED, THEY MAY RUN CONTINUOUS AT

CONTRACTOR'S OPTION.

REINFORCING BAR BENDS MUST BE MADE COLD.

UNLESS OTHERWISE SHOWN, WALL VERTICAL REINFORCING MUST BE

POSITIONED AT THE CENTER OF THE WALL.

DOWELS BETWEEN FOOTINGS AND WALLS MUST BE THE SAME GRADE, SIZE,

AND SPACING AS VERTICAL REINFORCING.

REINFORCING BARS MUST BE PROVIDED WITH THE FOLLOWING CONCRETE

COVER:

3.1.2

3.1.3

3.1.4

3.1.5

3.1.6

3.1.7

3.1.8

18"

18"

18"

1.0.7

1.

A.

B.

C.

D.

E.

F.

2.

DEFERRED SUBMITTALS:

THE DEFERRED SUBMITTAL ITEMS MUST NOT BE INSTALLED UNTIL

THEIR DESIGN AND SUBMITTAL DOCUMENTS HAVE BEEN

REVIEWED BY THE ARCHITECT OR ENGINEER OF RECORD AND

THAT THEY HAVE BEEN FOUND TO BE IN GENERAL CONFORMANCE

WITH THE DESIGN OF THE BUILDING.

STRUCTURAL STEEL SHOP DRAWINGS AND CONNECTION

DESIGN, EXCLUDING LATERAL CONNECTIONS PROVIDED

WITHIN THE CONTRACT DOCUMENTS.

STAIRS AND STAIR CONNECTIONS TO BUILDING/WALLS

LADDERS, GUARDRAILS, HANDRAILS AND THEIR COMPONENTS

SUPPORT ANCHORAGE OF MECHANICAL, ELECTRICAL AND

PLUMBING EQUIPMENT AND COMPONENTS

COLD-FORMED FRAMING /METAL STUDS CALCULATIONS AND

SHOP DRAWINGS INCLUDING LAYOUT, TYPICAL CONSTRUCTION

DETAILS, AND CONNECTIONS (ITEMS SHOWN IN PLANS ARE

MINIMUM SIZES REQUIRED)

SLAB ON GRADE CONTROL JOINT PLAN (PE SEAL NOT

REQUIRED FOR THIS ITEM)

THE ABOVE LISTED SUBMITTAL DOCUMENTS MUST BE STAMPED

AND SIGNED BY A REGISTERED PROFESSIONAL ENGINEER.

2.0.1

2.0.2

2.0.3

2.0.4

2.0.5

2.0.6

2.0.7

2.0.8

2.0.9

2.0.10

2.0 FOUNDATION:

SUBMIT COMPACTION TEST REPORTS FOR FILL BY A QUALIFIED TESTING LAB

TO ARCHITECT/ENGINEER & CONTRACTING OFFICER BEFORE FOUNDATION

PLACEMENT. LOOSE SOIL AND FILL DIRT MUST BE COMPACTEDTO A MINIMUM

OF 95% MAXIMUM DENSITY.

THE FOOTING EXCAVATIONS MUST BE KEPT FREE FROM LOOSE MATERIAL AND

STANDING WATER AND MUST BE NEAT AND TRUE TO LINE BEFORE CONCRETE

IS PLACED.

ABANDONED FOOTINGS, UTILITIES, ETC. THAT INTERFERE WITH NEW

CONSTRUCTION MUST BE REMOVED.

WALL FOOTINGS ARE CONTINUOUS POURED CONCRETE WITH CONTINUOUS

REINFORCING PLACED 3" CLEAR OF BOTTOM AND SIDES.

UNLESS OTHERWISE NOTED, WALL FOOTINGS ARE CENTERED UNDER WALLS

AND COLUMN FOOTINGS UNDER COLUMNS.

PROVIDE FOR DESIGN AND INSTALLATION OF CRIBBING, SHEATHING AND

SHORING REQUIRED TO SAFELY RETAIN GRADES.

PROVIDE FOR DE-WATERING OF EXCAVATIONS FROM SURFACE, GROUND, AND

OR SEEPAGE WATER.

CONT. EXT.

FTG.

MIN. FTG. WIDTH MIN. FTG. THICKNESS MIN. EMBEDMENT

CONT. INT.

FTG.

PAD (SPREAD)

FTG.

2'-0"

MIN. FOOTING SIZES

12" 18"

18"

18"

12"

12"

2'-0"

3'-0"

FOUNDATION DESIGN IN BASED ON A MAXIMUM NET ALLOWABLE SOIL

BEARING PRESSURE OF 5,000 PSF TO BE PROVIDED AFTER THE

INSTALLATION AND APPROVAL OF DENSIFIED DISPLACEMENT AGGREGATE

PIERS (DDAPS) FOR THE ENTIRE BUILDING FOUNDATION SYSTEM AS

RECOMMENDED IN THE AECOM GEOTECHNICAL ENGINEERING REPORT

REVISION DATED 30 JANUARY 2024 AND AS SPECIFIED. ALL WALL AND

COLUMN FOOTING MUST BE SUPPORTED ON DDAPS.

FOOTING DEPTHS SHOWN ARE A MINIMUM AND MAY REQUIRE DEEPENING

BASED ON SITE CONDITIONS.

FOOTINGS MUST BEAR ON FIRM UNDISTURBED OR COMPACTED SOIL.

MINIMUM FOOTING DIMENSIONS AND EMBEDMENTS MUST BE AS FOLLOWS:

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

YS

TE

M S

C O

M M

AN

D

DRAWFORM REVISION: 25 AUGUST 2020

DE

SI

GN

A

ND

C

ON

ST

RU

CT

IO

N (D C) C

OR

E

NA

VA

L

ST

AT

IO

N

- N

OR

FO

LK

, V A

M

AR

IN

E

C O

R

PS

B

AS

E C

AM

P

LE

JE

U N

E, N

C

P rin t D at e:

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

S

YS

TE

M

S C

O M

M

AN

D

M

ID

AT

LA

N

TI

C

AS INDICATED

HCNTRL

A2

APPROVED BY SOFIA SCHWARTZ

AMB DIRECTOR

MCB CAMP LEJEUNE

C :\U se rs

\h en ry .K

AY

D

O S-

D

AN

IE

LS

\D oc um en ts \S

TR

U

C T_

_A 2_

H C

N

TR

L_ ho ne w el l.r vt 4/

/2

:4

0:

A M

ST

R

U C

TU

R

AL

N

O

TE

S

S-003

1760523

FINAL SUBMITTAL

12915160

MARCH 19, 2025

BCC SAM LGG

DRR/KRT

NBJ

EJA

DSN

06 MAY 2025

P-

0T H

M

AR

IN

ES

O

PE

R

AT

IO

N

AL

C

O M

PL

EX

3.4.1

4.0.1

4.0.2

4.0.3

4.0.4

4.0.8

4.0.9

4.0.10

4.0.11

4.0.12

4.0.13

4.0.14

4.0.15

4.0.17

4.0.18

4.0.19

4.0.20

4.0.21

4.0.5

4.0.6

4.0.7

4.0.16

3.4.2

3.4.3

3.4.4

3.4.5

3.4.6

3.4.7

3.4 POWDER ACTUATED FASTENERS IN

HARDENED CONCRETE, MASONRY,

AND STEEL (SHOT PINS):

4.0 MASONRY:

POWDER ACTUATED FASTENING SYSTEMS:

CONCRETE MASONRY UNITS

MASONRY COMPONENTS

DESIGN STRENGTH: f'm = 2000 psi

MORTAR (TYPE S)

GROUT

STRENGTH @ 28 DAYS

2000 psi

3000 psi

1800 psi

MASONRY WORK MUST CONFORM TO INTERNATIONAL BUILDING CODE

(IBC), LATEST ADOPTED EDITION AS LISTED HEREIN.

CONCRETE MASONRY UNITS MUST BE MEDIUM WEIGHT UNITS IN

ACCORDANCE WITH ASTM C90 WITH MAXIMUM LINEAR SHRINKAGE OF 0.065%.

CEMENT MUST BE AS SPECIFIED FOR CONCRETE.

MORTAR MUST CONFORM TO ASTM C270

EXCERPTS FROM ASTM C270:

CCELLS BELOW GRADE MUST BE FULLY GROUTED UNLESS OTHERWISE

NOTED. ADDITIONALLY, CELLS WITH REINFORCING MUST BE FILLED SOLID

WITH GROUTED UNLESS OTHERWISE NOTED WITHIN THE SECTIONS AND

TYPICAL DETAILS.

NOTED.

GROUT MUST BE CONSOLIDATED WITH A MECHANICAL VIBRATOR.

MINIMUM 4000 rpm, 3/4" MAXIMUM HEAD. PROVIDE INSPECTION AND

CLEANOUT HOLES AT THE BASE OF GROUTED CELLS FOR LIFTS

GREATER THAN 5'-0".

WHEN GROUTING IS STOPPED FOR ONE HOUR OR LONGER, HORIZONTAL

CONSTRUCTION JOINTS MUST BE FORMED BY STOPPING THE GROUT

POUR 1 1/2" BELOW TOP OF THE UPPERMOST UNIT.

UNLESS OTHERWISE NOTED, MASONRY MUST BE CONSTRUCTED

WITH A RUNNING BOND PATTERN.

ELECTRIC CONDUIT BOXES AND/OR OTHER OBSTRUCTIONS ARE NOT

PERMITTED IN CELLS CONTAINING REINFORCING, UNLESS APPROVED BY

THE ENGINEER & CONTRACTING OFFICER.

UNLESS OTHERWISE SHOWN ON THE PLANS, LAP SPLICES OF

REINFORCING STEEL IN MASONRY MUST BE PER SCHEDULE.

HORIZONTAL REINFORCEMENT BARS MUST BE PLACED IN BOND BEAM

MASONRY UNITS.

LINTEL REINFORCEMENT BARS MUST BE PLACED IN LINTEL BEAM BLOCK.

VERTICAL REINFORCEMENT BARS MUST BE PLACED AT THE CENTER OFTHE

WALL UNLESS OTHERWISE SHOWN. VERTICAL BARS ARE TO BE TIED OR

OTHERWISE FIXED IN POSITION AT INTERVALS OF NOT MORE THAN 200

BAR DIAMETERS AND AT TOP AND BOTTOM.

ANCHOR BOLTS MUST BE SET WITH TEMPLATES AND HELD IN PLACE

PRIOR TO GROUTING.

PROVIDE A MINIMUM OF ONE BAR DIAMETER OF GROUT BETWEEN MAIN

REINFORCING AND MASONRY UNITS. PROVIDE A MINIMUM OF 1"

GROUT AROUND BOLTS EMBEDDED IN MASONRY.

TABLE 2 PROPERTY SPECIFICATION REQUIREMENTSA

MORTAR TYPE

AVG. COMPRESSIVE

STRENGTH AT 28

DAYS, MIN.

WATER

RETENTION,

MIN. %

AIR

CONTENT,

MAX. %B

AGGREGATE RATIO

(MEASURED IN DAMP,

LOOSE CONDITIONS)

GROUT MUST CONFORM TO ASTM C476.

EXCERPTS FROM ASTM C476:

CEMENT-

LIME

MORTAR

CEMENT

MASONRY

CEMENT

M

S

N

O

M

S

N

O

M

S

N

O

2500 psi

1800 psi

750 psi

350 psi

2500 psi

1800 psi

750 psi

350 psi

2500 psi

1800 psi

750 psi

350 psi

75 12

75 12

75 14

75 14

75 12

75 12

75 18

75 18

75 20

75 20

C

C

C

C

D

D

NOT LESS THAN 2 1

AND NOT MORE THAN

3 1

2 THE SUM OF

SEPARATE VOLUMES

OF CEMENTITIOUS

MATERIALS

A

LABORATORY PREPARED MORTAR ONLY

B

SEE NOTE

C

WHEN STRUCTURAL REINFORCEMENT IS INCORPORATED IN CEMENT-LINE OR

CEMENT MORTAR, THE MAX. AIR CONTENT MUST BE 12%.

D

WHEN STRUCTURAL REINFORCEMENT IS INCORPORATED IN MASONRY OR

CEMENT MORTAR, THE MAX. AIR CONTENT MUST BE 18%.

PROPORTIONS BY VOLUME (CEMENTITIOUS MATERIALS)

MORTAR TYPE

PORTLAND

CEMENT OR

BLENDED

CEMENT

CEMENT-

LIME

MORTAR

CEMENT

M

S

N

O

M

M

S

S

N

O

1/2

M

M

S

S

N

O

1/2

M S N M S N

TABLE 1 PROPORTION SPECIFICATION REQUIREMENTS

MASONRY

CEMENT

MORTAR

CEMENT

NOT LESS THAN

2 1

4 AND NOT

MORE THAN 31

THE SUM OF

SEPARATE

VOLUMES OF

CEMENTITIOUS

MATERIALS

AGGREGATE

RATIO (MEASURED

IN DAMP, LOOSE

CONDITIONS)

HYDRATED

LIME OR LIME

PUTTY

1/4

OVER 1/4 TO 1/2

OVER 1/2 TO 1 1/4

OVER 1 1/4 TO 2 1/2

MORTAR JOINTS MUST BE STRAIGHT, CLEAN AND UNIFORM IN THICKNESS,

AND MUST BE TOOLED AS SHOWN ON THE PLANS OR AS SPECIFIED (FLUSH

JOINTS IF NO SPECIAL TREATMENT SPECIFIED). UNLESS OTHERWISE

SPECIFIED OR DETAILED ON THE PLANS, HORIZONTAL AND VERTICAL MORTAR

JOINTS MUST BE 3/8" THICK WITH FULL MORTAR COVERAGE ON THE

FACE SHELL.

OVERHANGING MORTAR DROPPINGS AND DEBRIS MUST BE REMOVED

FROM CELLS RECEIVING GROUT. FAILURE TO REMOVE DEBRIS MUST BE

CAUSE FOR REJECTION OF WALL AND REPAIR OR REWORK NECESSARY

MUST BE ENTIRELY AT CONTRACTOR'S EXPENSE.

VERTICAL HEAD JOINTS MUST BE BUTTERED WELL FOR A THICKNESS EQUAL

TO THE FACE SHELL OF THE BLOCK AND THESE JOINTS MUST BE SHOVED

TIGHTLY SO THAT THE MORTAR BONDS WELL TO BOTH BLOCKS. IF IT IS

NECESSARY TO MOVE A BLOCK SO AS TO OPEN A JOINT, THE BLOCK MUST

BE REMOVED FROM THE WALL, CLEANED AND SET IN FRESH MORTAR

TABLE 2103.12

GROUT PROPORTIONS BY VOLUME FOR MASONRY CONSTRUCTION

PARTS BY VOLUME

OF PORTLAND

CEMENT OR

BLENDED CEMENT

PARTS BY

VOLUME OF

HYDRATED

LIME OR LIME

PUTTY

AGGREGATE, MEASURED IN A DAMP,

LOOSE CONDITION

FINE COARSE

TYPE

FINE GROUT 1 0-1/10

1 0-1/10COARSE

GROUT

2 1/4-3 TIMES THE

SUM OF THE

VOLUMES OF THE

CEMENTITIOUS

MATERIALS

2 1/4-3 TIMES THE

SUM OF THE

VOLUMES OF THE

CEMENTITIOUS

MATERIALS

1-2 TIMES THE SUM

OF THE VOLUMES

OF THE

CEMENTITIOUS

MATERIALS

4.0.8.1 SPECIFIED COMPRESSIVE STRENGTH- PROPORTIONS ESTABLISHED

BY 28-DAY COMPRESSIVE STRENGTH TESTS IN ACCORDANCE WITH

TEST METHOD C 1019 THAT OBTAIN THE SPECIFIED COMPRESSIVE

STRENGTH. THE GROUT MUST BE MIXED TO A SLUMP OF 8 in. TO 11

in. AS DETERMNINED BY TEST METHOD C 143/C 143M AND MUST HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 psi AT 28 DAYS.

A.

B.

C.

CONCRETE: FOR GENERAL CONCRETE AND LIGHTWEIGHT CONCRETE:

POWDER ACTUATED FASTENING SYSTEMS MUST BE INSTALLED PER

REQUIREMENTS OF THE ICC-ES EVALUATION SERVICES REPORT FOR THE

SPECIFIC FASTENER, AND AS REQUIRED BY THE MANUFACTURER.

MASONRY: POWDER ACTUATED FASTENING SYSTEMS MUST BE INSTALLED

PER THE REQUIREMENTS OF THE ICC-ES EVALUATION SERVICES REPORT

FOR SPECIFIC FASTENER, AND AS REQUIRED BY THE MANUFACTURER.

STEEL: POWDER ACTUATED FASTENING SYSTEMS MUST BE INSTALLED

PER THE REQUIREMENTS OF THE ICC-ES EVALUATION SERVICES REPORT

FOR THE SPECIFIC FASTENER, AND AS REQUIRED BY THE

MANUFACTURER.

WHEN INSTALLING POWDER ACTUATED FASTENERS IN EXISTING NON-

PRESTRESSED REINFORCED CONCRETE, USE CARE AND CAUTION TO AVOID

HITTING OR DAMAGE TO THE EXISTING REINFORCING BARS. MAINTAIN A MINIMUM

CLEARANCE OF 1" BETWEEN THE REINFORCEMENT AND THE FASTENER.

POWDER ACTUATED FASTENERS ARE NOT PERMITTED BY ASCE 7-16 SECTION

13.4.5 FOR SEISMIC TENSION LOAD APPLICATIONS. POWDER ACTUATED

FASTENERS MUST NOT BE USED TO CARRY SEISMIC TENSION LOADS (EXCEPT

FOR VERTICAL SEISMIC LOAD PRODUCED BY SELF-WEIGHT OF THE

COMPONENTS SUPPORTED) OR IN CRACKED CONCRETE UNLESS PRE-

APPROVED FOR SUCH LOADING BY THE…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .