This is a technical engineering drawing for a component of the Electron-Ion Collider project at Brookhaven National Laboratory. The document consists of two detailed sheets describing "Braze Fittings" and "Final Machining" for a specialized lid assembly with precise ultra-high vacuum (UHV) requirements. The assembly involves multiple components including a lid assembly, water plugs, brazed half nipples, and weld fittings, fabricated using gold and copper brazing materials with strict specifications. Key technical requirements include passing a helium leak test of 2x10^-10 std cc/sec, ensuring all braze joints are leak-tight with a maximum leak rate of 1x10^-9 atm cc He/sec, and being compatible with an ultra-high vacuum environment. The manufacturing process involves precise machining, brazing, and post-brazing finishing, with detailed tolerance specifications and material standards (ASTM B152, B187, A269) specified for each component.

View the file

Other files

Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A

B

C

D

6 5

G

E

F

NOTES:

H

8 6 5

24 3 1

A

D W G

N O

R E V S H T

O F

C

D

2 4 3

G

E

F

H

CREO

ELECTRON-ION COLLIDER

SCALE:

DRAWING NUMBER:

FINISH

APPLICATION

CATEGORY

Q.A.

UNLESS OTHERWISE SPECIFIED

DIMENSIONS ARE IN INCHES

USED ON DRAWING NO. QTY. PER ASS'Y.

BREAK SHARP EDGES

ANGULAR TOLERANCE �#�1�$�

DECIMAL TOLERANCES

.X �#� .030

.XX �#� .015

.XXX �#� .005

ACCORDANCE WITH

ASME Y14.5 2009

INTERPRET IN GENERAL

E

SIZE

SHEET OFWEIGHT:

UPTON, N.Y. 11973

REV.

.03 MAX. MIN. 015

BROOKHAVEN NATIONAL LABORATORYE I C

2X 90.0�$�

2X 90.0�$�

M

REVISION APPROVALS

SUPVENGDESCHKBYDATEDESCRIPTIONECN NO.REV

------1

ESR 704 MHZ FPC TEST

FINAL BRAZING ASSEMBLY

LID, BRAZED FITTINGS

2400M0166 1/2

397.3

2400M0170

1 2 A3DEPARTMENT

CHAIR

SAFETY / RSC

Q.A.

DIVISION

HEAD

CEE / CME

SUPERVISOR

APPROVAL

ENG / PHY

APPROVAL

DESIGN

APPROVAL

CHECKED

BY

DRAWN BY P-D. MALENDELE 07/25/25

BILL OF MATERIALS

REMARKSDESCRIPTIONPART NUMBERITEM

NUMBERQTY

ASTM B152LID ASSEMBLY MACHINING2400M016811

ASTM B187WATER PLUG2400M013128

BRAZED HALF NIPPLE, UPPER MACHINING2400M013532

ASTM A269WELD FITTINGS W/ 1" TUBE2400M013642

35Au/65CuGOLD & COPPER .002 BFM FOIL52

35Au/65CuGOLD & COPPER BRAZE WIRE .020 DIAMETER62

35Au/65CuGOLD & COPPER BRAZE WIRE .040 DIAMETER714

1. MAKE FROM 2400M0168-5 " LID "

2. FABRICATE IN ACCORDANCE WITH SPECIFICATION EIC-VSG-SPC-023.

3. ASSEMBLY TO BE USED IN ULTRA-HIGH VACUUM ENVIRONMENT AND MUST BE UHV COMPATIBLE.

4. ASSEMBLY MUST PASS A HELIUM LEAK TEST OF 2X10^-10 STD CC/SEC HE

5. ALL BRAZE JOINTS TO BE LEAK TIGHT. LEAK RATE NOT TO EXCEED 1 X 10e-9 ATM CC HE/SEC.

" BRAZE FITTINGS"

SEE DETAIL A

2X LEAK CHECK

SEE DETAIL B

SEE DETAIL C

ALIGN WITH SCRIBE MARKS

LOCATED ON ITEM #1

PRIOR TO BRAZE OPERATION

DETAIL A

SCALE 2/1

8X BRAZE BELOW FLUSH

PEEN IN PLACE

DETAIL B

SCALE 2/1

2X VIEW

2X BRAZE

DETAIL C

SCALE 2/1

2X VIEW

2X BRAZED

THIS INFORMATION IS CONTROLLED BY THE

U.S. DEPARTMENT OF COMMERCE EXPORT

CONTROL ADMINISTRATION REGULATIONS

15 CFR PARTS 730-774 AS EAR99 TECHNOLOGY

ISOMETRIC VIEW

FOR REFERENCE ONLY

REF

REF

REF

REF

REF

REF

APPROVED R&D

ELEC APPVL IN

W

INDCHILL

SHEET OF

E

CATEGORY:

Q.A.

WEIGHT:SCALE:

DRAWING NUMBER:SIZE

D W G

N O

A

REV.

S H T

O F

R E V

A

B

C

D

6 5

G

E

F

H

8 6 5

ELECTRON-ION COLLIDER

UPTON, N.Y. 11973

24 3

C

D

2 4 3

G

E

F

H

BROOKHAVEN NATIONAL LABORATORY

29.539 .001

( )30.16

7.045 16.075 ( )7.045

( )27.782 ( )1.1911.191

R

TYP.

.13

( )20.50

( )30.16

( )2.051

( )2.82

17.968

.954 .003 1.266

27.782

.879 .003

1.191

( )20.50

10.250

2X �n� THRU3.897

( )2.051

( )2.960

( )4.871

6.497

( )2.820

2.113

.707

1.266

( )17.968

( )1.266

2X R.13

R3.543

4X R.40

2X R.39

19.875 .001

4X �x�.688 �x�.03

.261 .002

2400M0166 A3

1/2 397.6 2 2

M

"FINAL MACHINING"

6. AFTER BRAZING MACHINE THE FOLLOWING:

- QUALIFY TOP SURFACE

- FINISH VACUUM PORT ID

- FINISH TOP POCKET

7. BREAK ALL SHARP EDGES .010 X 45 �$�

8. TAG PART WITH DRAWING NUMBER IN ACCORDANCE WITH MIL-STD-130.

SECTION B-B

T S

SECTION A-A