ATTACHMENT 7 - Fire Protection.pdf

PDF 10 MB Posted

Attached to
Y1DZ--Expand and Renovate B400 for Urgent and Primary Care (Minor) - Tomah
Solicitation number
36C77621B0009
Issued by

About this file

This document provides details for a federal contract solicitation to expand and renovate a building for urgent and primary care services. The solicitation number is 36C77621B0009 issued by the Department of Veterans Affairs Technology Acquisition Center Austin. Contractors are sought to completely prepare the site for building operations, including demolition and removal of existing structures, and furnish all labor, materials, and work required by the attached drawings and specifications to expand and renovate building B400 for urgent and primary care at the Tomah VA facility. Responses are due by the date specified in the solicitation document. The selected contractor will be expected to perform all tasks necessary as outlined in the drawings and specifications to ready the expanded and renovated facility space for its urgent and primary care purposes by dates set in the award documentation.

View the file

Other files

File Type Posted
31 23 19 DEWATERING.pdf PDF
36C77621B0009 0003.pdf PDF
Drawings VF100 - VF101.pdf PDF
Technical Questions - FINAL - Tomah 8-2-21.pdf PDF
36C77621B0009 0002.pdf PDF
ATTACHMENT 17 - Construction Wage Rates - Monroe County - 7-9-21.pdf PDF
Site Visit Sign-in Sheet - Tomah - 9 AM - 7-12-21.pdf PDF
36C77621B0009 0001.pdf PDF
Site Visit Sign-in Sheet - Tomah - 10 AM - 7-13-21.pdf PDF
ATTACHMENT 20 - Site Visit Registration - Map.pdf PDF
36C77621B0009 - 6-29-21.pdf PDF
ATTACHMENT 15 - Fire Alarm.pdf PDF
ATTACHMENT 16 - Contractor Core Work Hours.pdf PDF
ATTACHMENT 17 - Construction Wage Rates - Monroe County - 5-14-21.pdf PDF
ATTACHMENT 12 - Furniture.pdf PDF
ATTACHMENT 4 - Electrical.pdf PDF
ATTACHMENT 13 - Civil.pdf PDF
ATTACHMENT 11 - Architectual.pdf PDF
ATTACHMENT 8 - Equipment.pdf PDF
ATTACHMENT 1 - Specifications Final 6-21-21.pdf PDF
ATTACHMENT 6 - Plumbing.pdf PDF
ATTACHMENT 2 - General.pdf PDF
ATTACHMENT 19 - Contractor Safety - Environmental Form.docx DOCX document
ATTACHMENT 10 - Signage.pdf PDF
ATTACHMENT 18 - Limitations on Subcontracting - Construction.docx DOCX document
ATTACHMENT 5 - Mechanical.pdf PDF
ATTACHMENT 9 - Interiors.pdf PDF
ATTACHMENT 3 - Structural.pdf PDF
ATTACHMENT 14 - Hazard.pdf PDF
Show all 29

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ABOVE FINISHED FLOOR

ABOVE FINISHED GRADE

AMBIENT

AMERICAN NATIONAL STANDARDS

APPROXIMATE

BACKFLOW PREVENTER (TYPE AS INDICATED)

BOTTOM OF PIPE

BRITISH THERMAL UNIT PER HOUR

BALL VALVE

CUBIC FEET PER MINUTE

CAST IRON

COMPRESSOR

CONDENSATE

CONTINUATION

CHECK VALVE

DOWN

DRAWING

EACH

EFFICIENCY

ELEVATION

EXPANSION TANK

ENTERING WATER TEMPERATURE

EXPANSION

EXTERNAL

EXISTING MATERIAL OR EQUIPMENT

NIC NOT IN CONTRACT

NO. NUMBER

NOM NOMINAL

NTS NOT TO SCALE

OD OUTSIDE DIAMETER

ACCESS PANEL

AMERICANS WITH DISABILITIES ACT

ABBREVIATION

BRAKE HORSEPOWER

CAPACITY

DIAMETER

EQUIVALENT

N.C. NORMALLY CLOSED

NA NOT APPLICABLE

N.O. NORMALLY OPEN

DOMESTIC

OS&Y OUTSIDE SCREW AND YOKE

AFF

AFG

AMB

ANSI

APPROX

BFP

BOP

BTU/H

BV

CFM

CI

COMP

COND

CONT

CV

DN

DWG

EA

EFF

EL

ET

EWT

EXP

EXT

(E)

AP

ADA

ABBR

BHP

CAP.

DIA

EQ

DOM

FIRE

FAN COIL UNIT

FLOOR

FEET PER MINUTE

FEET OR FOOT

GALLON

GALLONS PER MINUTE

GATE VALVE

HEIGHT

HORSE POWER

HIGH PRESSURE STEAM

HOUR

DEGREES IN FAHRENHEIT

FEET PER SECOND

GALLONS PER HOUR

GALLONS PER DAY

MERCURY

FIRE HOSE VALVE

FLOW SWITCH

HYDRAULIC GRADE LINE

F

FCU

FL

FPM

FT

GAL

GPM

GV

HGT

HP

HPS

HR

°F

FPS

GPH

GPD

HG

FHV

FS

HGL

INSIDE DIAMETER

INVERT ELEVATION

IN. INCHES

KW KILOWATTS

LGT LENGTH

LWT LEAVING WATER TEMPERATURE

MAX MAXIMUM

MBH 1000 BTU/HR

MECH MECHANICAL

MIN MINIMUM

MISC MISCELLANEOUS

MTG MOUNTING

IE

ID

A

B

C

D

E

F

G

H

I

K

L

M

N

P

PRESS. PRESSURE

PRV PRESSURE REDUCING VALVE

PSI POUNDS PER SQUARE INCH

PSIG POUNDS PER SQUARE INCH - GAUGE

REF REFERENCE

RL RELOCATED MATERIAL OR EQUIPMENT

RPM REVOLUTIONS PER MINUTE

SCFM STANDARD CUBIC FEET PER MINUTE

SE SEWAGE EJECTOR

SF SQUARE FEET

SG SPECIFIC GRAVITY

SS STAINLESS STEEL

STM STEAM

TEMP TEMPERATURE

TYP TYPICAL

VEL VELOCITY

W/ WITH

WG WATER GAUGE

W/0 WITHOUT

PH PHASE (ELECTRICAL)

PPM PARTS PER MILLION

SPEC SPECIFICATION

SQ. FT. SQUARE FEET

STD STANDARD

UON UNLESS OTHERWISE NOTED

V VOLT

YD YARD

SPRINKLER/ STANDPIPE

SPRINKLERSPR

SPR/STP

TAMPER SWITCHTS

O

R

S

T

U

V

W

Y

TS

FS

NS

FIRE PROTECTION PIPING

FIRE HOSE VALVE

FIRE HOSE VALVE IN CABINET

THROUGH THE WALL, FIRE DEPARTMENT CONNECTION

FREE STANDING, FIRE DEPARTMENT CONNECTION

(SIAMESE)

FIRE PUMP TEST HEADER

VALVE SUPERVISORY SWITCH, TAMPER

ALARM CHECK VALVE

DRY PIPE VALVE

DELUGE VALVE

PRE-ACTION VALVE

FLOW SWITCH

(SIAMESE)

BACKFLOW PREVENTER

OS&Y VALVE

CHECK VALVE

INSPECTOR'S TEST CONNECTION

POST INDICATING VALVE

POINT OF DISCONNECT

POINT OF CONNECTION

ELBOW - TURNED DOWN

CAP OR PLUG

LH LIGHT HAZARD SPRINKLER DENSITY CLASSIFICATION

OH-1 ORDINARY HAZARD 1 SPRINKLER DENSITY CLASSIFICATION

EXISTING ROOM/AREA SPRINKLER SYSTEM TO

REMAIN. NO NEW WORK.

1. FIRE HYDRANT FLOW TEST DATA:

a. DATE TEST WAS PERFORMED: FALL 2012

b. TEST PERFORMED BY: FIRELINE

c. PRESSURE HYDRANT:

i. LOCATION: TOMAH, WI

ii. OUTLET ELEVATION: UNKNOWN

iii. STATIC PRESSURE (PSI): 72 PSI

iv. RESIDUAL PRESSURE (PSI): 60 PSI

d. FLOW HYDRANT:

i. LOCATION: B400 & 4TH ST.

ii. FLOW (GPM): 1012

2. SPRINKLER SYSTEM DESIGN CRITERIA:

a. LIGHT HAZARD OCCUPANCY -

ADMINISTRATIVE AREAS, COMPUTER ROOMS, ETC.

b. ORDINARY HAZARD OCCUPANCY - PARKING GARAGE, LOADING DOCK, STORAGE AREAS, MECHANICAL AND ELECTRIC ROOMS AND SIMILAR AREAS WHERE STOCKPILES OF COMBUSTIBLE MATERIALS DO NOT EXCEED 8'-0".

3. SYSTEM PROTECTION AREA LIMITATIONS:

a. THE MAXIMUM FLOOR AREA ON ANY ONE FLOOR TO BE PROTECTED BY SPRINKLERS SUPPLIED BY ANY ONE SPRINKLER RISER OR COMBINED SYSTEM SHALL BE 52,000 SQ FT FOR LIGHT AND ORDINARY HAZARD.

b. THERE IS NO LIMIT TO THE NUMBER OF FLOORS THAT CAN BE PROTECTED BY A SINGLE RISER, BECAUSE EACH FLOOR IS CONSIDERED A SEPERATE FIRE AREA.

4. SPRINKLER DESIGN DENSITIES/DEMAND CRITERIA:

a. LIGHT HAZARD - 0.10 GPM PER SQ FT OVER THE HYDRAULICLLY MOST REMOTE 1500 SQ FT.

b. ORDINARY HAZARD - 0.15 GPM PER SQ FT OVER THE HYDRAULICLLY MOST REMOTE 1500 SQ FT.

SPRINKLER HEAD

SPRINKLER HEAD SCHEDULE AND LEGEND

SYMBOL LOCATION MANUFACTURER SIN K-FACTOR SR/QR TYPE TEMP. FINISH

THREAD

SIZE

COMMENTS

ALL RENOVATED

AREAS.

VIKING VK302 5.6 QR SSP 150° BRASS 1/2" SEMI-RECESSED IN CEILINGS AND

EXPOSED FOR NO CEILINGS. SEE

ARCHITECTURAL PLAN REFLECTED

CEILINGS FOR REFERENCE.

PARTITION RATING GRAPHICS:

4 HR FIRE BARRIER

3 HR FIRE BARRIER

2 HR FIRE & SMOKE BARRIER

2 HR FIRE BARRIER

2 HR FIRE BARRIER/SHAFT

1 HR FIRE & SMOKE BARRIER

1 HR FIRE BARRIER

1 HR FIRE BARRIER/SHAFT

SMOKE PARTITION (NON RATED)

NON RATED

PARTITION RATING GRAPHIC DESIGNATION: PRIORITY

1 HIGHEST

5 LOWEST

PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE

RESISTANT, OR BOTH FIRE AND SMOKE RESISTANT ARE SHOWN

GRAPHICALLY ON PLANS WITH HATCH PATTERNS.

1. Deduct Alternate #1: Remove B407 North Swing Space.

a. Remove 60 days from schedule.

2. Deduct Alternate #2: Remove B407 South Swing Space, Bathroom refresh and IT closet infrastructure from project.

a. Remove 90 days from schedule.

3. Deduct Alternate #3: Remove sealed bubble wall fountain in Waiting Room 1082 from project.

a. Remove 14 days from schedule.

4. Deduct Alternate #4: Rebuild (E) AHU rather than install new one.

a. Remove 90 calendar days from schedule.

5. Deduct Alternate #5: Remove exterior entrance canopy at staff lounge 1102.

a. Remove 14 calendar days from schedule.

DEDUCTIVE ALTERNATE:

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMP

321 4 5 6 7 8 9 10

ARCHITECT/ENGINEER OF RECORD

A/E:

CONSULTANT

C&S Engineers, Inc.

2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com

Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com

Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com

B

IM

/6

-3

B

E x p a n d

R e lo c a te

U rg e n t

C a re A n d

R e n o v a te s t F lo o r P a ti e n t C a re

/6

-3

.4

.M

E P

.r v t

/2

/2

:0

:5

A

M

F000

FIRE PROTECTION ABBREVIATIONS

AND SYMBOLS

Expand and Renovate B400 for

Urgent and Primary Care

500 E Veterans St, Tomah, WI 54660

676-19-327

400/407

05/20/2021 K.LEITCH P.KOTTA

TRIPLE C - THE A&E GROUP

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

ISSUED FOR

CONSTRUCTION

1 DESIGN, FABRICATE, INSTALL AND TEST THE FIRE SPRINKLER SYSTEM(S) IN ACCORANCE WITH THE FOLLOWING CRITERIA: A. AUTHORITY HAVING JURSIDICITION, B. OWNERS INSURANCE CARRIER, C. NFPA 13.

2 ALL WORK INDICATED ON THE CONTRACTOR DOCUMENTS IS INTENDED AS A GUIDE ONLY. THE CONTRACTOR IS RESPONSIBLE FOR PRODUCING THE NECESSARY DOCUMENTS SIGNED AND SEALED BY A PROFESSIONAL FIRE PROTECTION ENGINEER TO BE SUBMITTED TO THE AHJ FOR APPROVAL.

3 BRING TO THE ATTENTION OF THE ARECHITECT/ENGINEER ANY DISCREPANCIES BETWEEN THE DRAWINGS AND SPECIFICATIONS.

4 PROVIDE SUPERVISORY SWITCHES AT LOCATIONS REQUIRED BY AHJ AND NFPA.

5 INSTALL PIPING SO THAT IT DRAINS BACK TO DRAIN VALVES AS REQUIRED BY NFPA.

6 MAINTAIN A MINIMUM OF 7' HEAD ROOM CLEARANCE.

7 ALL SPRINKLERS SHALL BE INSTALLED IN THE CENTER OF CEILING TILES.

8 SEE ARCHITECURAL DRAWINGS FOR HEAD LOCATINS IN SENSITIVE AREAS.

9 THE CONTRACTOR SHALL PERFORM ALL REQUIRED ACCEPTANCE TESTS AS INDICATED IN THE NFPA 13. A RECORD OF THE TEST SHALL BE SUBMITTED TO THE

FIRE DEPARTMENT ON THE APPROPRIATE NFPA FORM.

FIRE PROTECTION SHEET INDEX

F000 FIRE PROTECTION ABBREVIATIONS AND SYMBOLS

FD101 B400 - LEVEL 1 - FIRE PROTECTION DEMOLITION PLAN

FD102 B400 - LEVEL 2 - FIRE PROTECTION DEMOLITION PLAN

FD103-407 B407 - LEVEL 3 - FIRE PROTECTION DEMOLITION PLAN

FP101 B400 - LEVEL 1 - FIRE PROTECTION PLAN

FP102 B400 - LEVEL 2 - FIRE PROTECTION PLAN

FP103-407 B407 - LEVEL 3 - FIRE PROTECTION PLAN

FIRE PROTECTION GENERAL NOTES:SYMBOLS:ABBREVIATIONS:

FIRE HYDRANT DATA:

FIRE PROTECTION DETAILS:

Pending Totals: NEW Plumbing systems in crawl space and 1st floor are original. Provide complete new plumbing piping systems, basement, crawl space, 1st floor. Replace all cold water, hot water, drain, waste, and vent piping throughout.

Fixtures / Piping 111175 [ Field Engineer Review Completed on 07/29/2014 by VHATOMBueniM.] [ Auto Generated Project Pending on 07/29/2014 for Project Number 676-14- 122 created by VHATOMBueniM.] Project 676-14-122 replaced the sanitary and storm sewer piping under the west wing.

Replace piping in the basement and in the 1st and 2nd floors, which exceed maximum life expectancy.

Fire Sprinkler / Pump 90803 Sprinkler piping is in good condition.

Pending Totals: NEW Ambulance Bay exhaust fan Square inline May have a control issue. Fan was running continuously when no source of CO contamination was present. (2010 vintage

Ventil (O.A. & Exh) 111174 Ventilation is in good condition.

Room Air Dist/Term 111173 VAV boxes and reheating coils in good condition.

Heating System 277776 2nd floor steam piping and convectors removed, replaced by hot water heaters or air-side heating.

Heating System 111168 The original steam piping and convectors on the 1st floor has exceeded their life expectancy and should be replaced.

Engr. Control syst. 111167 METASYS controls on the 1st and 2nd floors installed in 2005 and are in good condition.

Ducts & Water Dist 111166 Ducts and piping in good condition.

Pending Totals: NEW Air Handler (2004) serving the current dental in good condition, Air Handler is Mixed Air, Pre-Filter, Air Blender, Hot Water Pumped Heating Coil, CW Cooling Coil, Diffuser, Supply Fan with ABB VFD, Filter, Steam Humidifier on discharge *AHU-8 Trane MN: MCCB025UAODOUA SN:K04M65739A

Mechanical Rec No Description

Building 400 FCA Report

Disclaimer: These items have been determined to have reached their end of life usefulnes. This scope of work contract did not allocate funding for the below mentioned deficiencies. The following information was received from the owner's assessment report dated 1/6/2017.

FCA Report:

Revisions: Date:

ARCHITECT/ENGINEER OF RECORD

A/E:

CONSULTANT

C&S Engineers, Inc.

2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com

Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com

Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com

TRIPLE C - THE A&E GROUP

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

43886

05/20/2021 KAEKO LEITCH

1 2 3 4 5 6 6.1 7 7.8 8 9 9.1 9.9 10 11 11.2 12 13 14 18171615

M.3

M

L

K.3

K

J.3

J

I.5

I

H.1

H

G

F.1

F

E

D

C

B

A

(E) 6" FIRE SERVICE

IN BASEMENT

EXISTING TO

REMAIN FDC

(E )6

F

(E)2 1/2" F

(E)6" F

(E )6

F

EXISTING 2-1/2"

TO RISER REMAIN

EXISTING 6"

STANDPIPE

TO REMAIN

(E)2 1/2" F

(E)2 1/2" F

EXISTING FIRE SPRINKLER SYSTEM

TO BE RECONFIGURED TO

ACCOMMODATE RENOVATION AND

ADDITION. NO EXISTING FIRE

SPRINKLER PLANS FOR THE

AFFECTED AREAS ARE PROVIDED.

FIELD VERIFICATION BY FIRE

SPRINKLER CONTRACTOR IS

REQUIRED.

EXISTING FIRE SPRINKLER SYSTEM

TO BE RECONFIGURED TO

ACCOMMODATE RENOVATION AND

ADDITION. NO EXISTING FIRE

SPRINKLER PLANS FOR THE

AFFECTED AREAS ARE PROVIDED.

FIELD VERIFICATION BY FIRE

SPRINKLER CONTRACTOR IS

REQUIRED.

EXISTING 2-1/2" FIRE

SPRINKLER MAIN AND

BRANCH PIPES TO BE

MODIFIED TO ACCOMMODATE

RENOVATION.

FIRE SPRINKLER AREA

EXISTING TO REMAIN.

EXISTING 2-1/2" FIRE

SPRINKLER MAIN AND

BRANCH PIPES TO BE

MODIFIED TO ACCOMMODATE

RENOVATION.

FIRE SPRINKLER AREA

EXISTING TO REMAIN.

LIGHT HAZARD AREA

FIRE PROTECTION ZONING LINE

FIRE PROTECTION LEGEND:

EXAM

1027 EXAM

EXAM

OFFICE

OFFICE

OFFICE

OFFICE

EXAM

OFFICE

OFFICE

DIRTY UTILTIY

OFFICE

WAITING

NURSE STATION

OFFICE

EXAM

CONFERENCE

EXAM

EXAM

EXAM

OFFICE

OFFICE

WOMEN

VISITOR

TOILET

TLT

MECH

IT

1005 OFFICE

OFFICE

OFFICE

EXAM

STAIR

WAITING / CIRCULATION

EXAM

EXAM

EXAM

NURSE STATION

1085 EXAM

EXAM

WOMEN TLT

EXAM

EXAM

OFFICE

STORAGE

1096A

STAFF TOILET

STAFF TOILET

AMBULANCE GARAGE

IT

1051B

ELECT

1051A

N

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMP

321 4 5 6 7 8 9 10

GENERAL NOTES

KEY PLAN

KEYNOTES

AREA A

B400 KEY PLAN

AREA B

AREA

A1

AREA C

ARCHITECT/ENGINEER OF RECORD

A/E:

CONSULTANT

C&S Engineers, Inc.

2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com

Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com

Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com

B

IM

/6

-3

B

E x p a n d

R e lo c a te

U rg e n t

C a re A n d

R e n o v a te s t F lo o r P a ti e n t C a re

/6

-3

.4

.M

E P

.r v t

/2

/2

:0

:0

A

M

FD101

B400 - LEVEL 1 - FIRE PROTECTION

DEMOLITION PLAN

Expand and Renovate B400 for

Urgent and Primary Care

500 E Veterans St, Tomah, WI 54660

676-19-327

400/407

05/20/2021 K.LEITCH P.KOTTA

TRIPLE C - THE A&E GROUP

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

ISSUED FOR

CONSTRUCTION

SCALE: 1/8" = 1'-0"

F1

B400 - LEVEL 1 - FIRE PROTECTION DEMOLITION PLAN

A. FIRE PROTECTION CONTRACTOR TO PROVIDE COMPLETE PLANS,

APPROVALS AND INSTALLATION PER NFPA STANDARDS, LOCAL CODES

AND VA STANDARDS.

B. PROVIDE COMPLETE FIRE PROTECTION SYSTEM INCLUDING, BUT NOT

LIMITED TO, ALL NECESSARY PIPING, VALVES, FITTING, TAMPER

SWITCHES & FLOW SWITCHES.

C. ALL WORK TO BE COORDINATED WITH OTHER TRADES BEFORE

INSTALLATION. REMOVAL OF ANY PENETRATIONS THRU EXISTING WALLS

OR FLOORS TO BE PROPERLY SEALED.

D. PERFORM FLOW TEST FROM NEAREST HYDRANTS AND VERIFY SEASONAL

VARIATIONS WITH WATER UTILITIES.

E. COORDINATE TEMPORARY FIRE COVERAGE DURING CONSTRUCTION GRC

AND FACILITIES.

F. SPRINKLER HEADS HAVE BEEN LOCATED BY LIDAR SURVEY. SPRINKLER

MAINS HAVE BEEN PROVIDED BY VA PROVIDED INFORMATION.

1. NOT USED.

Revisions: Date:

ARCHITECT/ENGINEER OF RECORD

A/E:

CONSULTANT

C&S Engineers, Inc.

2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com

Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com

Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com

TRIPLE C - THE A&E GROUP

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

M

L

K.3

K

J.4

J

I.5

I

H.1

H

G

F.1

F

E

D

C

B

A

(E)2 1/2" F

(E )2

/2

F

EXISTING FIRE SPRINKLER SYSTEM

TO BE RECONFIGURED TO

ACCOMMODATE RENOVATION AND

ADDITION. NO EXISTING FIRE

SPRINKLER PLANS FOR THE

AFFECTED AREAS ARE PROVIDED.

FIELD VERIFICATION BY FIRE

SPRINKLER CONTRACTOR IS

REQUIRED.

EXISTING 2-1/2" FIRE

SPRINKLER MAIN AND

BRANCH PIPES TO BE

MODIFIED TO ACCOMMODATE

RENOVATION.

EXISTING 6"

STANDPIPE TO

REMAIN

LIGHT HAZARD AREA

FIRE PROTECTION ZONING LINE

FIRE PROTECTION LEGEND:

OFFICE

UNOCCUPIED

CLEAN UTILITY

LAB

MECHANICAL

OFFICE

2015A

TOILET, STAFF

2030A

UTILITY ROOM, SOILED

TOILET

LOCKER ROOM

LAB

TREATMENT ROOM

EXAM/ TREATMENT ROOM

EXAM/ TREATMENT ROOM

TREATMENT ROOM

EXAM/TREATMENT ROOM

TREATMENT ROOM

STAIR

S9

N

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMP

321 4 5 6 7 8 9 10

GENERAL NOTES

KEY PLAN

KEYNOTES

AREA A

B400 KEY PLAN

AREA B

AREA

A1

AREA C

ARCHITECT/ENGINEER OF RECORD

A/E:

CONSULTANT

C&S Engineers, Inc.

2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com

Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com

Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com

B

IM

/6

-3

B

E x p a n d

R e lo c a te

U rg e n t

C a re A n d

R e n o v a te s t F lo o r P a ti e n t C a re

/6

-3

.4

.M

E P

.r v t

/2

/2

:0

:0

A

M

FD102

B400 - LEVEL 2 - FIRE PROTECTION

DEMOLITION PLAN

Expand and Renovate B400 for

Urgent and Primary Care

500 E Veterans St, Tomah, WI 54660

676-19-327

400/407

05/20/2021 K.LEITCH P.KOTTA

TRIPLE C - THE A&E GROUP

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

ISSUED FOR

CONSTRUCTION

SCALE: 1/8" = 1'-0"

F1

B400 - LEVEL 2 - FIRE PROTECTION DEMOLITION PLAN

A. FIRE PROTECTION CONTRACTOR TO PROVIDE COMPLETE PLANS,

APPROVALS AND INSTALLATION PER NFPA STANDARDS, LOCAL CODES

AND VA STANDARDS.

B. PROVIDE COMPLETE FIRE PROTECTION SYSTEM INCLUDING, BUT NOT

LIMITED TO, ALL NECESSARY PIPING, VALVES, FITTING, TAMPER

SWITCHES & FLOW SWITCHES.

C. ALL WORK TO BE COORDINATED WITH OTHER TRADES BEFORE

INSTALLATION. REMOVAL OF ANY PENETRATIONS THRU EXISTING WALLS

OR FLOORS TO BE PROPERLY SEALED.

D. PERFORM FLOW TEST FROM NEAREST HYDRANTS AND VERIFY SEASONAL

VARIATIONS WITH WATER UTILITIES.

E. COORDINATE TEMPORARY FIRE COVERAGE DURING CONSTRUCTION GRC

AND FACILITIES.

F. SPRINKLER HEADS HAVE BEEN LOCATED BY LIDAR SURVEY. SPRINKLER

MAINS HAVE BEEN PROVIDED BY VA PROVIDED INFORMATION.

1. NOT USED.

Revisions: Date:

ARCHITECT/ENGINEER OF RECORD

A/E:

CONSULTANT

C&S Engineers, Inc.

2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com

Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com

Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com

TRIPLE C - THE A&E GROUP

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

407.A

407.B1

407.C1

407.D1

407.E

407.F

407.G1

407.H

407.I

407.J

407.K

407.L

407.M

407.N

407.14407.11 407.12.1407.12

407.9407.7

407.41407.4407.3407.21

J.39

J.40

J.41

407.H2

407.H1

407.13.1

OPEN OFFICE

RESTROOM

OPEN OFFICE

MECH / ELEC

RESTROOM

EXISTING FIRE SPRINKLER SYSTEM

TO BE RECONFIGURED TO

ACCOMMODATE RENOVATION AND

ADDITION. NO EXISTING FIRE

SPRINKLER PLANS FOR THE

AFFECTED AREAS ARE PROVIDED

AND LIMITED INFORMATION IS

AVAILABLE FROM FIELD VISITS. FIELD

VERIFICATION BY FIRE SPRINKLER

CONTRACTOR IS REQUIRED.

EXISTING FIRE SPRINKLER SYSTEM

TO BE RECONFIGURED TO

ACCOMMODATE RENOVATION AND

ADDITION. NO EXISTING FIRE

SPRINKLER PLANS FOR THE

AFFECTED AREAS ARE PROVIDED

AND LIMITED INFORMATION IS

AVAILABLE FROM FIELD VISITS. FIELD

VERIFICATION BY FIRE SPRINKLER

CONTRACTOR IS REQUIRED.

DEDUCT ALT 1:

REMOVE WORK

ASSOCIATED WITH

B407 NORTH.

DEDUCT ALT 2:

REMOVE WORK

ASSOCIATED WITH

B407 SOUTH.

MECH / ELECT

3790C

OFFICE

3790B

BEDROOM

BEDROOM

MECHANICAL ROOM

3780A

MECHANICAL ROOM

BEDROOM

MEDS

3711A

BEDROOM

STORAGE

DINING

3749A

BREAK

3765 BEDROOM

WARD

READING

BEDROOM

TREATMENT

CT CLINIC

TOILET

3744A

CLOSET

SHOWERS

3784A

DRESSING

DRESSING

SHOWERS

3715A

Room

DAY ROOM

TOILET

CLOSET

3750A

CORRIDOR

7C36

CORRIDOR

7C31

DATA CLOSET

3772A

ELECTRICAL

CORRIDOR

7C38

CORRIDOR

7C39

OFFICE

STAIR

S4

CORRIDOR

7C37

CORRIDOR

7C32

HAC

3736A

NURSES

BEDROOM

BEDROOM

READING

UTILITY

WARD

STAIR

S6

DINING

LOCKERS

WARD

BEDROOM

BEDROOM

CLEAN LINENS

Room

CLOSET

ELEVATOR LOBBY

7C35

ELEVATOR

CORRIDOR

CORRIDOR

7C33

BEDROOM

LAUNDRY

DEDUCT ALT 2:

REMOVE WORK

ASSOCIATED WITH

B407 SOUTH.

DEDUCT ALT 2:

REMOVE WORK

ASSOCIATED WITH

B407 SOUTH.

DEDUCT ALT 2:

REMOVE WORK

ASSOCIATED WITH

B407 SOUTH.

EXISTING SIDEWALL

SPRINKLER HEADS TO REMAIN

IN AREA

EXISTING SIDEWALL

SPRINKLER HEADS

TO REMAIN IN AREA

LIGHT HAZARD AREA

FIRE PROTECTION ZONING LINE

FIRE PROTECTION LEGEND:

N

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMP

321 4 5 6 7 8 9 10

GENERAL NOTES

KEYNOTES

B407 KEY PLAN

AREA A

KEY PLAN

ARCHITECT/ENGINEER OF RECORD

A/E:

CONSULTANT

C&S Engineers, Inc.

2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com

Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com

Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com

B

IM

/6

-3

B

E x p a n d

R e lo c a te

U rg e n t

C a re A n d

R e n o v a te s t F lo o r P a ti e n t C a re

/6

-3

.4

.M

E P

.r v t

/2

/2

:0

:0

A

M

FD103-407

B407 - LEVEL 3 - FIRE PROTECTION

DEMOLITION PLAN

Expand and Renovate B400 for

Urgent and Primary Care

500 E Veterans St, Tomah, WI 54660

676-19-327

400/407

05/20/2021 K.LEITCH G.RHODEN

TRIPLE C - THE A&E GROUP

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

ISSUED FOR

CONSTRUCTION

SCALE: 1/8" = 1'-0"

B407 - LEVEL 3 - FIRE PROTECTION DEMOLITION PLAN

A. FIRE PROTECTION CONTRACTOR TO PROVIDE COMPLETE PLANS,

APPROVALS AND INSTALLATION PER NFPA STANDARDS, LOCAL CODES

AND VA STANDARDS.

B. PROVIDE COMPLETE FIRE PROTECTION SYSTEM INCLUDING, BUT NOT

LIMITED TO, ALL NECESSARY PIPING, VALVES, FITTING, TAMPER

SWITCHES & FLOW SWITCHES.

C. ALL WORK TO BE COORDINATED WITH OTHER TRADES BEFORE

INSTALLATION. REMOVAL OF ANY PENETRATIONS THRU EXISTING WALLS

OR FLOORS TO BE PROPERLY SEALED.

D. PERFORM FLOW TEST FROM NEAREST HYDRANTS AND VERIFY SEASONAL

VARIATIONS WITH WATER UTILITIES.

E. COORDINATE TEMPORARY FIRE COVERAGE DURING CONSTRUCTION GRC

AND FACILITIES.

F. SPRINKLER HEADS HAVE BEEN LOCATED BY LIDAR SURVEY. SPRINKLER

MAINS HAVE BEEN PROVIDED BY VA PROVIDED INFORMATION.

1. NOT USED.

Revisions: Date:

ARCHITECT/ENGINEER OF RECORD

A/E:

CONSULTANT

C&S Engineers, Inc.

2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com

Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com

Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com

TRIPLE C - THE A&E GROUP

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

M

L

K.3

K

J.4

J

I.5

I

H.1

H

G

F.1

F

E

D

C

B

A

EXISTING SIAMESE

FIRE DEPARTMENT

CONNECTION

(E)2 1/2" F (E)2 1/2" F

EXISTING

2-1/2" RISER

TO REMAIN

EXISTING 6"

STANDPIPE TO

REMAIN

(E)2 1/2" F

(E)2 1/2" F

AREA TO SHOW EXISTING FIRE

SPRINKLER MAIN ONLY. NEW

BRANCH MAIN TO CLINICAL

AREA MAY BE NECESSARY PER

FIRE SPRINKLER CONTRACTORS

HYDRAULIC CALCULATIONS.

AREA TO SHOW EXISTING FIRE

SPRINKLER MAIN ONLY. NEW

BRANCH MAIN TO URGENT CARE

AREA MAY BE NECESSARY PER

FIRE SPRINKLER CONTRACTORS

HYDRAULIC CALCULATIONS.

FIRE SPRINKLER AREA

EXISTING TO REMAIN.

CONF

CONSULT ROOM 2

CONSULT ROOM 1

CLEAN UTILITY

EXAM 10

CHAIR EXAM

1085b

EXAM 6

ANTE ROOM

1108A

OFFICE

EXAM 8

ALCOVE

WHEELCHAIR ALCOVE

EQ. ALCOVE

EXAM 13 / CONSULT RM 3

EXAM 2

TEAM WORK STATIONS

WAITING

1032B

TEAM AREA

1101A

TEAM AREA

1086A

PATIENT TLT

TLT

1022B

STAFF TLT

1019B

MECH

STAFF TOILET

BARIATRIC/ WOMENS HEALTH TLT

1100B

TLT

1104B

TLT/SHWR

EXAM 2 - NEGATIVE PRESS

1104A

MEDS

EXAM 4

EXAM 5 BARIATRIC/ WOMENS HEALTH

1100A

RECEPT CHECK IN/OUT

1032A

WEIGH AREA

MEDS

CORRIDOR

OC11

EXAM 12

FAMILY TLT

NURSE MANAGER OFFICE

OFFICE

CLEAN SUPPLY

EXAM 7

SOILED UTILITY / SPD

CORRIDOR

OC13

EXAM 1

TLT

1108C

LOGISTICS STORAGE

AMBULANCE BAY

TELEHEALTH

TRIAGE

RECEPTION

1080C

TELEHEALTH

STOR

EXAM 7

CLEAN UTLITY

VESTIBULE

EXAM 9

STAFF LOUNGE

EXAM 1- NEGATIVE PRESS

1108B

WAITING

CORRIDOR

OC20

SOILED UTILITY

CORRIDOR

OC21

CORRIDOR

OC19

CORRIDOR

OC22

HALLWAY

OC14

EXAM 8

EXAM 11

LACTATION

IT

1051B

ELECT

1051A

HAC

TLT MENTAL HEALTH

1099B

MAIN ELEC A

1104C MAIN ELEC B

1104D

MENTAL HEALTH

1099A

FIRE SPRINKLER AREA

EXISTING TO REMAIN.

LIGHT HAZARD AREA

FIRE PROTECTION ZONING LINE

FIRE PROTECTION LEGEND:

N

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMP

321 4 5 6 7 8 9 10

GENERAL NOTES

KEY PLAN

KEYNOTES

AREA A

B400 KEY PLAN

AREA B

AREA

A1

AREA C

ARCHITECT/ENGINEER OF RECORD

A/E:

CONSULTANT

C&S Engineers, Inc.

2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com

Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com

Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com

B

IM

/6

-3

B

E x p a n d

R e lo c a te

U rg e n t

C a re A n d

R e n o v a te s t F lo o r P a ti e n t C a re

/6

-3

.4

.M

E P

.r v t

/2

/2

:0

:1

A

M

FP101

B400 - LEVEL 1 - FIRE PROTECTION

PLAN

Expand and Renovate B400 for

Urgent and Primary Care

500 E Veterans St, Tomah, WI 54660

676-19-327

400/407

05/20/2021 K.LEITCH P.KOTTA

TRIPLE C - THE A&E GROUP

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

ISSUED FOR

CONSTRUCTION

SCALE: 1/8" = 1'-0"

F1

B400 - LEVEL 1 - FIRE PROTECTION PLAN

1 IN THIS SHADED AREA CENTER NEW

RECESSED SPRINKLER HEADS IN NEW

CEILING TILE AND MODIFY EXISTING

BRANCH PIPING AS REQUIRED TO

ACCOMMODATE NEW LOCATION.

A. FIRE PROTECTION CONTRACTOR TO PROVIDE COMPLETE PLANS,

APPROVALS AND INSTALLATION PER NFPA STANDARDS, LOCAL CODES

AND VA STANDARDS.

B. PROVIDE COMPLETE FIRE PROTECTION SYSTEM INCLUDING, BUT NOT

LIMITED TO, ALL NECESSARY PIPING, VALVES, FITTING, TAMPER

SWITCHES & FLOW SWITCHES.

C. ALL WORK TO BE COORDINATED WITH OTHER TRADES BEFORE

INSTALLATION. REMOVAL OF ANY PENETRATIONS THRU EXISTING WALLS

OR FLOORS TO BE PROPERLY SEALED.

D. PERFORM FLOW TEST FROM NEAREST HYDRANTS AND VERIFY SEASONAL

VARIATIONS WITH WATER UTILITIES.

E. COORDINATE TEMPORARY FIRE COVERAGE DURING CONSTRUCTION GRC

AND FACILITIES.

F. FINAL LAYOUT AND SPRINKLER COUNT TO BE BY SPRINKLER

CONTRACTOR.

G. FIRE CAULK PIPE PENTERATIONS AT RATED WALLS, CEILING, AND

FLOORS. REFER THE ARCHITECTURE SHEET GI101, GI102, AND GI104 FOR

FIRE RATINGS.

H. CONCEALED SPRINKLER HEADS NOT ALLOWED, PROVIDE FAST ACTING

SEMI-RECESSED HEADS.

I. FINAL LAYOUT AND SPRINKLER COUNT TO BE BY SPRINKLER

CONTRACTOR.

Revisions: Date:

ARCHITECT/ENGINEER OF RECORD

A/E:

CONSULTANT

C&S Engineers, Inc.

2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com

Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com

Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com

TRIPLE C - THE A&E GROUP

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

M

L

K.3

K

J.4

J

I.5

I

H.1

H

G

F.1

F

E

D

C

B

A

(E)2 1/2" F (E)2 1/2" F

(E )2

/2

F

EXISTING 6"

STANDPIPE TO

REMAIN

AREA TO SHOW EXISTING FIRE SPRINKLER

MAIN ONLY. NEW BRANCH MAIN TO CLINICAL

AREA MAY BE NECESSARY PER FIRE

SPRINKLER CONTRACTORS HYDRAULIC

CALCULATIONS.

MECH

INFUSION ROOM

MECH

EXAM 1

CLEAN UTILITY - LOGISTICS

TLT

TEAM WORK AREA

MED EQUIPMENT STORAGE

EXAM 5

EXAM 3

EXAM 2

EXAM 4

CORRIDOR

OC22

CLEAN LINENS

SOILED UTILITY

SOILED UTILITY

LIGHT HAZARD AREA

FIRE PROTECTION ZONING LINE

FIRE PROTECTION LEGEND:

N

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMP

321 4 5 6 7 8 9 10

GENERAL NOTES

KEY PLAN

KEYNOTES

AREA A

B400 KEY PLAN

AREA B

AREA

A1

AREA C

ARCHITECT/ENGINEER OF RECORD

A/E:

CONSULTANT

C&S Engineers, Inc.

2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com

Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com

Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com

B

IM

/6

-3

B

E x p a n d

R e lo c a te

U rg e n t

C a re A n d

R e n o v a te s t F lo o r P a ti e n t C a re

/6

-3

.4

.M

E P

.r v t

/2

/2

:0

:2

A

M

FP102

B400 - LEVEL 2 - FIRE PROTECTION

PLAN

Expand and Renovate B400 for

Urgent and Primary Care

500 E Veterans St, Tomah, WI 54660

676-19-327

400/407

05/20/2021 K.LEITCH P.KOTTA

TRIPLE C - THE A&E GROUP

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

ISSUED FOR

CONSTRUCTION

SCALE: 1/8" = 1'-0"

F1

B400 - LEVEL 2- FIRE PROTECTION PLAN

1 IN THIS SHADED AREA CENTER NEW

RECESSED SPRINKLER HEADS IN NEW

CEILING TILE AND MODIFY EXISTING

BRANCH PIPING AS REQUIRED TO

ACCOMMODATE NEW LOCATION.

A. FIRE PROTECTION CONTRACTOR TO PROVIDE COMPLETE PLANS,

APPROVALS AND INSTALLATION PER NFPA STANDARDS, LOCAL CODES

AND VA STANDARDS.

B. PROVIDE COMPLETE FIRE PROTECTION SYSTEM INCLUDING, BUT NOT

LIMITED TO, ALL NECESSARY PIPING, VALVES, FITTING, TAMPER

SWITCHES & FLOW SWITCHES.

C. ALL WORK TO BE COORDINATED WITH OTHER TRADES BEFORE

INSTALLATION. REMOVAL OF ANY PENETRATIONS THRU EXISTING WALLS

OR FLOORS TO BE PROPERLY SEALED.

D. PERFORM FLOW TEST FROM NEAREST HYDRANTS AND VERIFY SEASONAL

VARIATIONS WITH WATER UTILITIES.

E. COORDINATE TEMPORARY FIRE COVERAGE DURING CONSTRUCTION GRC

AND FACILITIES.

F. FINAL LAYOUT AND SPRINKLER COUNT TO BE BY SPRINKLER

CONTRACTOR.

G. FIRE CAULK PIPE PENTERATIONS AT RATED WALLS, CEILING, AND

FLOORS. REFER THE ARCHITECTURE SHEET GI101, GI102, AND GI104 FOR

FIRE RATINGS.

H. CONCEALED SPRINKLER HEADS NOT ALLOWED, PROVIDE FAST ACTING

SEMI-RECESSED HEADS.

I. FINAL LAYOUT AND SPRINKLER COUNT TO BE BY SPRINKLER

CONTRACTOR.

Revisions: Date:

ARCHITECT/ENGINEER OF RECORD

A/E:

CONSULTANT

C&S Engineers, Inc.

2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com

Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com

Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com

TRIPLE C - THE A&E GROUP

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

407.A

407.B1

407.C1

407.D1

407.E

407.F

407.G1

407.H

407.I

407.J

407.K

407.L

407.M

407.N

407.14407.11 407.12.1407.12

407.9407.7

407.41407.4407.3407.21

J.39

J.40

J.41

407.H2

407.H1

407.13.1

OFFICE

3790A MECH / ELECT

3790C

OFFICE

3775B

OPEN OFFICE

OFFICE

3790B

MECH / ELEC

OPEN OFFICE

DEDUCT ALT 1:

REMOVE WORK

ASSOCIATED WITH

B407 NORTH.

DEDUCT ALT 2:

REMOVE WORK

ASSOCIATED WITH

B407 SOUTH.

DEDUCT ALT 2:

REMOVE WORK

ASSOCIATED WITH

B407 SOUTH.

DEDUCT ALT 2:

REMOVE WORK

ASSOCIATED WITH

B407 SOUTH.

DEDUCT ALT 2:

REMOVE WORK

ASSOCIATED WITH

B407 SOUTH.

EXISTING SIDEWALL

SPRINKLER HEADS TO REMAIN

IN AREA

EXISTING SIDEWALL

SPRINKLER HEADS

TO REMAIN IN AREA

EXISTING

SPRINKLER HEADS

TO REMAIN IN AREA

LIGHT HAZARD AREA

FIRE PROTECTION ZONING LINE

FIRE PROTECTION LEGEND:

N

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMP

321 4 5 6 7 8 9 10

GENERAL NOTES

KEYNOTES

B407 KEY PLAN

AREA A

KEY PLAN

ARCHITECT/ENGINEER OF RECORD

A/E:

CONSULTANT

C&S Engineers, Inc.

2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com

Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com

Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com

B

IM

/6

-3

B

E x p a n d

R e lo c a te

U rg e n t

C a re A n d

R e n o v a te s t F lo o r P a ti e n t C a re

/6

-3

.4

.M

E P

.r v t

/2

/2

:0

:2

A

M

FP103-407

B407 - LEVEL 3 - FIRE PROTECTION

PLAN

Expand and Renovate B400 for

Urgent and Primary Care

500 E Veterans St, Tomah, WI 54660

676-19-327

400/407

05/20/2021 K.LEITCH P.KOTTA

TRIPLE C - THE A&E GROUP

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

ISSUED FOR

CONSTRUCTION

SCALE: 1/8" = 1'-0"

F1

B407 - LEVEL 3 - FIRE PROTECTION PLAN

1 IN THIS SHADED AREA CENTER NEW

RECESSED SPRINKLER HEADS IN NEW

CEILING TILE AND MODIFY EXISTING

BRANCH PIPING AS REQUIRED TO

ACCOMMODATE NEW LOCATION.

A. FIRE PROTECTION CONTRACTOR TO PROVIDE COMPLETE PLANS,

APPROVALS AND INSTALLATION PER NFPA STANDARDS, LOCAL CODES

AND VA STANDARDS.

B. PROVIDE COMPLETE FIRE PROTECTION SYSTEM INCLUDING, BUT NOT

LIMITED TO, ALL NECESSARY PIPING, VALVES, FITTING, TAMPER

SWITCHES & FLOW SWITCHES.

C. ALL WORK TO BE COORDINATED WITH OTHER TRADES BEFORE

INSTALLATION. REMOVAL OF ANY PENETRATIONS THRU EXISTING WALLS

OR FLOORS TO BE PROPERLY SEALED.

D. PERFORM FLOW TEST FROM NEAREST HYDRANTS AND VERIFY SEASONAL

VARIATIONS WITH WATER UTILITIES.

E. COORDINATE TEMPORARY FIRE COVERAGE DURING CONSTRUCTION GRC

AND FACILITIES.

F. FINAL LAYOUT AND SPRINKLER COUNT TO BE BY SPRINKLER

CONTRACTOR.

G. FIRE CAULK PIPE PENTERATIONS AT RATED WALLS, CEILING, AND

FLOORS. REFER THE ARCHITECTURE SHEET GI101, GI102, AND GI104 FOR

FIRE RATINGS.

H. CONCEALED SPRINKLER HEADS NOT ALLOWED, PROVIDE FAST ACTING

SEMI-RECESSED HEADS.

I. FINAL LAYOUT AND SPRINKLER COUNT TO BE BY SPRINKLER

CONTRACTOR.

Revisions: Date:

ARCHITECT/ENGINEER OF RECORD

A/E:

CONSULTANT

C&S Engineers, Inc.

2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com

Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com

Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com

TRIPLE C - THE A&E GROUP

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

GI000-COVER SHEET
GI001-PROJECT SHEET INDEX
GI050-GENERAL NOTES
GI101-B400 -LEVEL 1 -FIRE AND LIFE SAFETY PLAN & CODE DATA
GI102-B400 -LEVEL 2 -FIRE AND LIFE SAFETY PLAN & CODE DATA
GI104-B407 -LEVEL 3 -FIRE AND LIFE SAFETY PLAN & CODE DATA -DEDUCT ALT #1 & #2
GI201-INFECTION CONTROL PLAN & INTERIM LIFE
GC101-PROJECT PHASING
GC102-PHASING PLANS
H101-B400 -LEVEL 1 -HAZARDOUS MATERIAL ABATEMENT
H102-B400 -LEVEL 2 -HAZARDOUS MATERIAL ABATEMENT
H103-407-B407 -LEVEL 3 -HAZARDOUS MATERIAL ABATEMENT
HC101-B400 -LEVEL 1 -HAZARDOUS MATERIAL ABATEMENT -PIPING
VF100-CONTROL POINT SITE PLAN
VF101-viuvTiiig i iuvCIVIL SURVEY PLAN
CD101-CIVIL DEMOLITION PLAN
CS101-CIVIL SITE PLAN
COo-CIVIL SITE PLAN STAGING AREA
CG101-CIVIL GRADING PLAN
CG501-CIVIL DETAIL SHEET 1
CG502-CIVIL DETAIL SHEET 2
CU101-CIVIL UTILITY PLAN
SJ001-GENERAL STRUCTURAL NOTES
SJ002-GENERAL STRUCTURAL NOTES CONTINUED
SJ003-SPECIAL INSPECTIONS
SB100-B400 -LEVEL 1 -FOUNDATION PLAN -OVERALL
SB101-B400 -LEVEL 1 - FOUNDATION PLAN -AREA A
SF102-B400 -LEVEL 2 - FRAMING PLAN -OVERALL
SF103-B400 -LEVEL 2 -ROOF FRAMING PLAN -AREA A
SF201-FRAMING ELEVATIONS
SF202-FRAMING ELEVATIONS
SF203-FRAMING ELEVATIONS
SF501-TYPICAL DETAILS
SF502-TYPICAL DETAILS
SF503-TYPICAL DETAILS
SF504-TYPICAL DETAILS
SF505-TYPICAL DETAILS
SB510-FOUNDATION DETAILS
SF520-FRAMING DETAILS
SF521-FRAMING DETAILS
SF530-COLD-FORMED STEEL FRAMING
SF601-GRAPHICAL COLUMN SCHEDULE
AE000-SYMBOLS, & GENERAL NOTES
AS101-ARCHITECTURAL SITE PLAN
AG100-FLOOR PLAN -LEVEL 1, URGENT CARE CENTER PROGRAM PLAN
AG103-FLOOR PLAN -LEVEL 1, CLINICAL SPACE PROGRAM PLAN
AG200-FLOOR PLAN -LEVEL 2, SPECIALTY CARE PROGRAM PLAN
AG201A-FLOOR PLAN -LEVEL 3 -SWING SPACE LAYOUT B407-DEDUCT ALT #1 & #2
AD101-B400 -LEVEL 1 -DEMOLITION PLAN
AD102-B400 -LEVEL 2 -DEMOLITION PLAN
AD103-407-B407 -LEVEL 3 -DEMOLITION PLAN -DEDUCT AL #1 & #2
AD121-B400 -LEVEL 1 -DEMOLITION RCP
AD122-B400 -LEVEL 2 -DEMOLITION RCP
AD123-407-B407 -LEVEL 3 -DEMOLITION RCP -DEDUCT ALT #1 & #2
AE101-B400 -LEVEL 1 -FLOOR PLAN -OVERALL
AE102-B400 -LEVEL 2 -FLOOR PLAN -OVERALL
AE103-407-B407 -LEVEL 3 -FLOOR PLAN -DEDUCT ALT #1& #2
AE104-B400 -ROOF PLAN -OVERALL
AC101-B400 -LEVEL 1 -REFLECTED CEILING PLAN
AC102-B400 -LEVEL 2 -REFLECTED CEILING PLAN
AC103-407-B407 -LEVEL 3 -REFLECTED CEILING PLAN -DEDUCT ALT #1 & #2
AE201-B400 EXTERIOR ELEVATIONS
AE201-407-B407 EXTERIOR ELEVATIONS -DEDUCT ALT #1 & #2
AE202-B400 EXTERIOR ELEVATIONS
AE301-BUILDING SECTIONS
AE320-WALL SECTIONS
AE321-WALL SECTIONS
AE322-WALL SECTIONS
AE401-B400 -LEVEL 1 -ENLARGED FLOOR PLANS
AE401A-B400 -LEVEL 1 -ENLARGED FLOOR PLANS
AE401B-B400 -LEVEL 1 -ENLARGED FLOOR PLANS
AE401C-B400 -LEVEL 1 -ENLARGED FLOOR PLANS
AE401D-B400 -LEVEL 1 -ENLARGED FLOOR PLANS
AE402-B400 -LEVEL 2 -ENLARGED FLOOR PLANS
AE500-EXTERIOR WALL AND ROOF ASSEMBLIES
AE520-EXTERIOR SECTION DETAILS
AE521-EXTERIOR SECTION DETAILS
AE551-DETAILS -INTERIOR
AE552-DETAILS -INTERIOR
AE560-DOOR DETAILS
AE561-DOOR AND LOUVER DETAILS
AE601-DOOR WINDOW & LOUVER SCHEDULES
AE710-ARCHITECTURAL DOOR, WINDOW & FRAME TYPES
AE720-STANDARD PARTITION TYPES
AE721-PARTITION HEAD DETAILS
AE722-PARTITION FRAMING DETAILS
AE730-TYPICAL MOUNTING HEIGHTS
AG900-B400 RENDERINGS
AG901-B400 RENDERINGS
AG902-B400/ B407 RENDERINGS
AW001-SIGNAGE ABBREVIATIONS, SYMBOLS, GENERAL NOTES & DETAILS
AW101-B400 -LEVEL 1 -SIGNAGE PLAN
AW102-B400 -LEVEL 2 -SIGNAGE PLAN
AW103-B407 -LEVEL 3 -SIGNAGE PLAN -DEDUCT ALT #1 & #2
IN001-NTERIOR FINISH ABBREVIATIONS, SYMBOLS, GENERAL NOTES & FINISH BOARDS
IN101-B400 -LEVEL 1 -INTERIOR FINISH PLAN -OVERALL
IN101A-B400 -LEVEL 1 -INTERIOR FINISH PLANS -AREA & A1
IN101B-B400 -LEVEL 1 -INTERIOR FINISH PLANS -AREA
IN102C-B400 -LEVEL 2 -INTERIOR FINISH PLANS -AREA C
IN103D-B407 -LEVEL 3 -INTERIOR FINISH PLANS -AREA A, B & C -DEDUCT ALT #1& #2
IN501-INTERIOR FINISH DETAILS
IN601-INTERIOR FINISH LEGEND AND SCHEDULES
IF101AB-B400 -LEVEL 1 -INTERIOR FURNITURE PLAN -FOR REFERENCE ONLY
IF102C-B400 -LEVEL 2 -INTERIOR FURNITURE PLAN -FOR REFERENE ONLY
IF103D-B407 -LEVEL 3 -INTERIOR FURNITURE PLAN -FOR REFERENCE ONLY -DEDUCT ALT #1 & #2
IF104-FURNITURE PLAN -FOR REFERENCE ONLY
IF105-FURNITURE PLAN -FOR REFERENCE ONLY
IF106-FURNITURE PLAN -FOR REFERENCE ONLY
Q001-EQUIPMENT SCHEDULE
Q101AB-B400 -LEVEL 1 -EQUIPMENT PLANS
Q101C-B400 -LEVEL 2 -EQUIPMENT PLAN
F000-FIRE PROTECTION ABBREVIATIONS AND SYMBOLS
FD101-B400 -LEVEL 1 - FIRE PROTECTION DEMOLITION PLAN
FD102-B400 -LEVEL 2 - FIRE PROTECTION DEMOLITION PLAN
FD103-407-B407 -LEVEL 3 - FIRE PROTECTION DEMOLITION PLAN
FP101-B400 -LEVEL 1 - FIRE PROTECTION PLAN
FP102-B400 -LEVEL 2 - FIRE PROTECTION PLAN
FP103-407-B407 -LEVEL 3 - FIRE PROTECTION PLAN
P-000-PLUMBING ABBREVIATIONS AND SYMBOLS
PD100-B400 -FOUNDATION -PLUMBING DEMOLITION PLAN
PD101-B400 -LEVEL 1 -PLUMBING DEMOLITION PLAN
PD102-B400 -LEVEL 2 -PLUMBING DEMOLITION PLAN
PD201-B400 -LEVEL 1 -MED GAS DEMOLITION PLAN
P-100-B400 -FOUNDATION -PLUMBING PLAN
P-101-B400 -LEVEL 1 -PLUMBING PLAN
P-102-B400 -LEVEL 2 -PLUMBING PLAN
P103-407-B407 -LEVEL 3 -PLUMBING PLAN
P-201-B400 -LEVEL 1 -MED GAS PLAN
P-300-B400 -PLUMBING ENLARGED PLANS
P-301-B400 -PLUMBING ENLARGED PLANS
P-302-B400 -PLUMBING ENLARGED PLANS
P-303-B400 -PLUMBING ENLARGED PLANS
P-304-B400 -PLUMBING ENLARGED PLANS
P-305-B400 -PLUMBING ENLARGED PLANS
P-400-PLUMBING RISERS
P-401-PLUMBING RISERS
P-402-PLUMBING RISERS
P-403-PLUMBING RISERS
P-404-PLUMBING RISERS
P-500-PLUMBING DETAILS
P-700-PLUMBING SCHEDULES
M-000-MECHANICAL ABBREVIATIONS AND SYMBOLS
MD101-B400 -LEVEL 1 -HVAC DEMOLITION PLAN
MD101A-B400 -LEVEL 1 -HVAC DEMO PLAN -DEDUCT ALT. #4
MD102-B400 -LEVEL 2 -HVAC DEMOLITION PLAN
MD103-407-B407 -LEVEL 3 -HVAC DEMOLITION PLAN
MD200-B400 -FOUNDATION -HVAC PIPING DEMOLITION PLAN
MD201-B400 -LEVEL 1 -HVAC PIPING DEMOLITION PLAN
MD202-B400 -LEVEL 2 -HVAC PIPING DEMOLITION PLAN
M-100-B400 -LEVEL 1 -HVAC TEMPORARY PLAN
M-101-B400 -LEVEL 1 - HVAC PLAN
M-101A-B400 -LEVEL 1 - HVAC PLAN -DEDUCT ALT. #4
M-102-B400 -LEVEL 2 - HVAC PLAN
M-103-407-B407 -LEVEL 3 - HVAC PLAN
MP200-B400 -FOUNDATION -HVAC PIPING PLAN
MP201-B400 -LEVEL 1 -HVAC PIPING PLAN
MP202-B400 -LEVEL 2 -HVAC PIPING PLAN
MP203-407-B407 -LEVEL 3 -HVAC PIPING PLAN
M-400-ENLARGED MECHANICAL PLANS
M-401-ENLARGED MECHANICAL PLANS
M-402-ENLARGED MECHANICAL PLANS -DEDUCT ALT. #4
M-500-MECHANICAL DETAILS
M-501-MECHANICAL DETAILS
M-502-MECHANICAL DETAILS
M-600-MECHANICAL SECTIONS
M-700-MECHANICAL SCHEDULES
M-800-MECHANICAL CONTROLS
M-801-MECHANICAL CONTROLS
M-802-MECHANICAL CONTROLS
E-000-ELECTRICAL ABBREVIATIONS AND SYMBOLS
ED101-B400 -LEVEL 1 - ELECTRICAL DEMOLITION PLAN
ED102-B400 -LEVEL 2 - ELECTRICAL DEMOLITION PLAN
ED103-407-B407 -LEVEL 3 - ELECTRICAL DEMOLITION PLAN
EL101-B400 -LEVEL 1 - LIGHTING PLAN
EL102-B400 -LEVEL 2 - LIGHTING PLAN
EL103-407-B407 -LEVEL 3 - LIGHTING PLAN
EL111-B400 -LEVEL 1 -LIGHTING CALCS
EL112-B400 -LEVEL 2 -LIGHTING CALCS
EL113-407-B407 -LEVEL 3 -LIGHTING CALCS
EP101-B400 -LEVEL 1 - POWER PLAN
EP102-B400 -LEVEL 2 - POWER PLAN
EP103-407-B407 -LEVEL 3 - POWER PLAN
EY101-B400 -LEVEL 1 - SPECIAL SYSTEMS PLAN
EY102-B400 -LEVEL 2 - SPECIAL SYSTEMS PLAN
EY103-407-B407 -LEVEL 3 - SPECIAL SYSTEMS PLAN
E-501-ELECTRICAL DETAILS
E-601-B400 ELECTRICAL DIAGRAMS
E-602-B400 ELECTRICAL DIAGRAMS
E-700-ELECTRICAL SCHEDULES
EF101-B400 -LEVEL 1 - FIRE ALARM DEMOLITION PLAN
EF102-B400 -LEVEL 2 - FIRE ALARM DEMOLITION PLAN
EF103-407-B407 -LEVEL 3 - FIRE ALARM DEMOLITION PLAN
EF201-B400 -LEVEL 1 - FIRE ALARM PLAN
EF202-B400 -LEVEL 2 - FIRE ALARM PLAN
EF203-407-B407 -LEVEL 3 - FIRE ALARM PLAN

File details come from the government source that posted it. Updated .