ATTACHMENT 4 - Electrical.pdf
PDF 12 MB Posted
- Solicitation number
- 36C77621B0009
About this file
This document provides details for a federal contract opportunity to expand and renovate an existing medical facility. The Department of Veterans Affairs Technology Acquisition Center Austin is soliciting bids under solicitation number 36C77621B0009 to completely prepare the site for building operations at the Tomah VA Medical Center in Wisconsin. This includes demolition and removal of existing structures as well as furnishing all labor, materials, and work to expand and renovate the B400 building for urgent and primary care services as outlined in the attached drawings and specifications, specifically the electrical drawings and specifications in Attachment 4. Bidders should reference the provided solicitation number and opportunity details when preparing a response for this contract by the specified response date to expand and upgrade primary care facilities for veterans at the Tomah VA Medical Center.
View the file
Other files
Show all 29
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FF-X
CUH-X
P
C
TC
C
12"x2"
A
A
#X
PT
ML
D
REX
P
C
K
J
J
V
C
S
S
M
M
S
SD
RT
C
F
S
S
H
H
HD
HD
SD
SD
SD
SD
SD
SD
SD
FD
A
M
R
SV
FS
TS
DIZ
DPE
SB
IZ
H
PE
F
F
#X
FA
SD
SBC
SS
PS
R
D
HD
M
C
VFD-X
T
DO
DO
E
T
T
H
TR
D
DF
G
G
TGB
TMGB
A
SI
a
D
A a
A a
A a
A a
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A a
T S
0-10V
P
U
D
MC
P
LV
KMC
L
LTS
LC
K
A V
I
I
I
I
GEN
A
H
S
D N
N
V N
S N
B
E
NC
A
J
E-1
E-1
HEARING AID
VISITOR INTERCOM
NURSE CALL WALL DOUBLE SIDED LIGHT -
1,2 OR 4 LIGHTS
NURSE CALL ANNUNCIATOR PANEL
NURSE CALL WALL LIGHT - 1,2 OR 4 LIGHTS
VISUAL NURSE CALL STATION
GEN-SET ANNUNCIATOR PANEL
INTERCOM HANDSET OUTLET
INTERCOM CALL SWITCH AND SPEAKER
NURSE CALL STATION
NURSE CALL DUTY STATION
NURSE CALL ZONE LIGHT - 1,2 OR 4 LIGHTS
NURSE CALL EMERGENCY STATION
NURSE CALL BATH STATION
NURSE CALL STAFF STATION
INTERCOM CALL SWITCH AND SPEAKER-SECURITY
RELAY
PHOTOCELL
LOWER CASE LETTER INDICATES SWITCH CIRCUIT ID (IF USED), LETTER
INDICATES TYPE, ARROWS INDICATE DIRECTION.
TYPE
SW ID
SINGLE POLE RECEPTACLE
PENDANT FIXTURE
CEILING FAN
(SUBSCRIPT INDICATES TYPE)
NURSE CALL
FIRE/SMOKE DAMPER
0-10V DIMMER SWITCH
3-WAY DIMMER SWITCH
UL924 RELAY
DAYLIGHT SENSOR - DIGITAL
DAYLIGHT SENSOR
POWER PACK (LETTER INDICATES TYPE)
AUTOMATIC LIGHTING CONTROL
CONDUIT IN WALL OR CEILING
CONDUIT IN FLOOR OR UNDERGROUND
HAND DRYER
DROP CORD OUTLET
ISOLATED DUPLEX RECEPTACLE
GFCI DUPLEX RECEPTACLE
MANUAL MOTOR SWITCH
CAR POST HEATER
TAMPER PROOF RECEPTACLE
DOUBLE DUPLEX RECEPTACLE
SPECIAL RECEPTACLE
RECEPTACLE DEVICE ON EMERGENCY CIRCUIT
MOTOR
HALF SWITCH DUPLEX RECEPTACLE
IN-GRADE LIGHT FIXTURE (ARROW INDICATES AIMING DIRECTION)
DIGITAL SWITCH
DIGITAL DIMMER SWITCH
SMOKE DETECTOR- WALL MOUNTED
REMOTE TEST SWITCH
FIRE ALARM CHIME STROBE
SERIAL INTERFACE, ISOLATED RELAY, ETC.)
LIGHTING CONTROL DEVICE (PARTITION SENSOR,
DUAL TECHNOLOGY (CEILING) - DIGITAL
ULTRASONIC (CEILING) - DIGITAL
PIR (CEILING) - DIGITAL
DUAL TECHNOLOGY (CEILING) - STAND ALONE
ULTRASONIC (CEILING) - STAND ALONE
PIR (CEILING) - STAND ALONE
ULTRASONIC (CEILING) - DIGITAL
ULTRASONIC (CEILING) - STAND ALONE
LIGHTING TOUCH SCREEN
ROOM CONTROLLER (LIGHTING / AV EQUIP)
DUAL TECHNOLOGY (WALL) - DIGITAL
DUAL TECHNOLOGY (CEILING) - DIGITAL
ULTRASONIC (WALL) - DIGITAL
ULTRASONIC (CEILING) - DIGITAL
PIR (WALL) - DIGITAL
PIR (CEILING) - DIGITAL
DUAL TECHNOLOGY (WALL) - STAND ALONE
DUAL TECHNOLOGY (CEILING) - STAND ALONE
ULTRASONIC (WALL) - STAND ALONE
ULTRASONIC (CEILING) - STAND ALONE
PIR (WALL) - STAND ALONE
PIR (CEILING) - STAND ALONE
CAST-IN-PLACE FLOOR BOX (LETTER INDICATES TYPE)
ELECTRICAL SYMBOLS
DUCT SMOKE DETECTOR- IONIZATION
DUCT SMOKE DETECTOR- PHOTO ELECTRIC
SMOKE DETECTOR- SOUNDER BASE
SMOKE DETECTOR- IONIZATION
SMOKE DETECTOR- WITH HEAT DETECTOR
SMOKE DETECTOR- PHOTO ELECTRIC
ACCESS
CONTACTOR
RELAY
VARIABLE FREQUENCY DRIVE
EQUIPMENT/CONTROL CABINET
PANELBOARD
COMBINATION STARTER DISCONNECT
TELEPHONE/DATA BACKBOARD
METER SOCKET
LOW VOLTAGE TRANSFORMER
MAGNETIC MOTOR STARTER
DISCONNECT
DISTRIBUTION
FIRE ALARM
AUDIO/VISUAL
MISCELLANEOUS
ELECTRIC HEATING
LIGHTING CONTROL
ELECTRICAL DEVICE
LIGHTING
WIRING AND RACEWAY
SHEET
FIRE ALARM RELAY
FIRE ALARM SPEAKER/STROBE
FIRE ALARM SPEAKER
FLAME DETECTOR
POWER SUPPLY
POWER TRANSFER DEVICE
REQUEST TO EXIT
PROXIMITY READER
PROJECTOR
MOTORIZED DAMPER, INTERLOCK WITH MOTOR #X
MASTER CLOCK STATION
CLOCK SPEAKER
DOOR BELL/CHIME
120V SINGLE STATION SMOKE DETECTOR
INDIVIDUAL ADDRESSABLE MONITOR MODULE
INDIVIDUAL ADDRESSABLE CONTROL MODULE
FIRE/SMOKE DAMPER (MECHANICAL)
DUAL HEAD PARKING LOT LIGHT FIXTURE
CEILING EMERGENCY BATTERY LIGHT FIXTURE
STUB-OUT/TERMINATION
BREAK OR CONTINUATION
GROUND
FAN FORCED HEATER
CEILING RADIANT HEAT PANEL
CARD READER
LOW-VOLTAGE SWITCH
RECESSED LIGHT FIXTURE ON EMERGENCY/LIFE SAFETY
PUSHBUTTON (LETTER(S) INDICATES TYPE)
GARAGE DOOR SAFETY SWITCH
SURFACE LIGHT FIXTURE ON EMERGENCY/LIFE SAFETY
STRIP LIGHT
ADA DOOR OPENER
MAGNETIC DOOR LOCK
CAMERA
RESIDENT ROOM NIGHT LIGHT
BELL
HUMIDISTAT
TRIPLE PUSH BUTTON
FIRE ALARM ANNUNCIATOR PANEL
WALL MOUNTED JUNCTION BOX
SINGLE HEAD PARKING LOT LIGHT FIXTURE
LIGHT FIXTURE ON EMERGENCY/LIFE SAFETY
RECESSED MOUNTED LIGHT FIXTURE (2X4 AND 2X2 REPRESENTED)
SHEET NUMBER SHOWN (E-1)
WITH DRAWING NUMBER SHOWN (1) AND
ELEVATION / SECTION NOTE REFERENCE
SHEET NUMBER SHOWN (E-1)
WITH DRAWING NUMBER SHOWN (1) AND
DETAIL NOTE REFERENCE
SHEET NOTE REFERENCE
REVISION NOTE REFERENCE
SURFACE MOUNTED LIGHT FIXTURE
DOOR POSITION SWITCH/DOOR CONTACTOR
SYSTEMS OUTLET (# & LETTER INDICATES QUANTITY & TYPE)
COMBINATION RATE OF RISE HEAT DETECTOR
TAMPER SWITCH
SOLENOID VALVE
FIRE ALARM HORN
DOUBLE PUSH BUTTON
SINGLE PUSH BUTTON
HORN SPEAKER
COMBINATION AUDIO/VISUAL FIRE ALARM
THERMOSTAT BY DIVISION 23
THERMOSTAT BY DIVISION 26
TIME CLOCK
FIRE ALARM STROBE LIGHT
MANUAL PULL STATION
FIXED TEMPERATURE HEAT DETECTOR W/ SETTING
FLOW SWITCH
MAGNETIC DOOR HOLDER
CLOCK - WALL MOUNTED
WALL SPEAKER
(LETTER INDICATES TYPE)
RECESSED CEILING SPEAKER
MICROPHONE OUTLET
VOLUME CONTROL SWITCH
DUAL MICROPHONE OUTLET
KEYPAD
ELECTRIC DOOR STRIKE
CABINET UNIT HEATER (CUH)
EMERGENCY BATTERY LIGHT FIXTURE
WALL MOUNTED LIGHT FIXTURE
RECESSED LIGHT FIXTURE
EMERGENCY LIGHT/REMOTE HEAD
SURFACE LIGHT FIXTURE
BOLLARD TYPE SITE LIGHT FIXTURE
NON-CONTINUOUS CABLE SUPPORTS
CEILING EXIT LIGHT FIXTURE
WALL EXIT LIGHT FIXTURE
DARK DASHED INDICATES ITEMS TO BE REMOVED
SINGLE POLE SWITCH
KEYED SWITCH
FOUR-WAY SWITCH
THREE-WAY SWITCH
SWITCH AND PILOT LIGHT
DIMMER SWITCH
JUNCTION BOX
POKE-THRU FLOOR BOX (LETTER INDICATES TYPE)
ELECTRIC HEAT
CONDUIT STUB-DOWN
CONDUIT STUB-UP
LADDER RACK
CABLE TRAY (NUMBERS INDICATE SIZE)
DUPLEX 20A, 125V,2P,3W RECEPTACLE
KEYED MOMENTARY CONTACT SWITCH
MOMENTARY CONTACT SWITCH
* ALL SYMBOLS AND ABBREVIATIONS DO NOT NECESSARILY APPEAR ON DRAWINGS *
SMOKE DETECTOR- SOUNDER BASE W / CO
HAND OFF-AUTO SWITCH
DUPLEX RECEPTACLE ON DEDICATED CIRCUIT
REMOTE DEAD FRONT GFCI TEST/RESET SWITCH
GROUND BAR (TMGB)
GROUND BAR (TGB)
TIME SWITCH
AV ROUGH-IN / JACKS
S
S
S
D
D
D
S
S
S
S
S
S
S
D
S
S
GFCI DOUBLE DUPLEX RECEPTACLE
MOTOR WITH MOTOR RATED
TOGGLE SWITCH DISCONNECT
S
U DUPLEX RECEPTACLE WITH USB
ELECTRIC BASEBOARD HEAT
OS EXISTING GENERIC OCCUPANCY SENSOR
RB REMOTE BATTERY
CO CARBON DIOXIDE DETECTOR
FSD
S
A
A
DUPLEX RECEPTACLE FLOOR MOUNTED
HORIZONTAL DUPLEX RECEPTACLE
PRV
PNL
PMH
PH
PA
P
NUCC
NO
NL
NIC
NF
NEU
NEMA
NEC
NC
MTS
MTD
MSWBD
MIN
MFS
MFG
MGA
MECH
MDP
M.C.
MCC
XFMR
WP
WH
WG
W/
VA
V
UH
UG
TYP
TV
TSTAT
THRU
TELE
TCR
TCP
SWBD
SUSE
STRUC
SSS
SPC
SE
RS
RNC
RMC
RGP
PVC
ELECTRICAL
ELECTRICAL CONTRACTOR
DRAWING
DOWN
DIRECT BURIED
CABINET UNIT HEATER
CONTRACTOR
COMMUNICATION
COMBINATION
CIRCUIT
CUBIC FEET PER MINUTE
CLOSED CIRCUIT TELEVISION
CRITICAL CARE
CIRCUIT BREAKER
CABINET
CONDUIT
BELOW CABINET
AUTOMATIC TRANSFER SWITCH
APPROXIMATE
AUDIO/ VISUAL
ANNUNCIATOR
ABOVE GRADE
ABOVE FINISHED FLOOR
AIR CONDITIONER
ABOVE COUNTER
AMPERE
AT
ELEC
E.C.
DWG
DN
DB
CUH
CONTR
COMM
COMB
CCT
CFM
CCTV
CC
C.B.
CAB
C.
BC
ATS
APPROX
A/V
ANNUC
AG
AFF
A/C
AC
A
@ POWER ROOF VENTILATOR
PANELBOARD
PULSE START METAL HALIDE
PHASE
PUBLIC ADDRESS
PUMP
CONDUIT WITH CONDUCTORS
NONMETALLIC UNDERGROUND
NORMALLY OPEN
NIGHT LIGHT
NOT IN CONTRACT
NON-FUSED
NEUTRAL
NATIONAL ELEC MFG ASSOCIATION
NATIONAL ELECTRICAL CODE
NORMALLY CLOSED
MANUAL TRANSFER SWITCH
MOUNTED
MAIN SWITCHBOARD
MINIMUM
MAXIMUM FUSE SIZE
MANUFACTURER
MEDICAL GAS ALARM PANEL
MECHANICAL
MAIN DISTRIBUTION PANEL
MECHANICAL CONTRACTOR
MOTOR CONTROL CENTER
KILOVOLT AMPS
LIFE SAFETY
LIQUID TIGHT FLEXIBLE NONMETALLIC CONDUIT
LIQUID TIGHT FLEXIBLE METAL CONDUIT
INTERMEDIATE METAL CONDUIT
HORSEPOWER OR HEAT PUMP
HAND-OFF-AUTO
GROUND
GROUND FAULT CIRCUIT INTERRUPT
GENERAL CONTRACTOR
FEET
FIBER OPTIC
FLEXIBLE METALLIC TUBING
FLEXIBLE METAL CONDUIT
FIRE ALARM CONTROL UNIT
FIRE ALARM ANNUNCIATOR
FIRE ALARM
EXPLOSION PROOF
EXHAUST FAN
EXISTING
EYE WASH/ EMERGENCY SHOWER
ELECTRIC WATER COOLER
EQUIPMENT SUPPLIER
ELECTRICAL NONMETALLIC TUBING
ENCLOSURE
ELECTRICAL METALLIC TUBING
ELEVATION OR ELEVATOR
KVA
LS
LFNC
LFMC
IMC
HP
HOA
GND
GFCI
G.C.
FT
FO
FMT
FMC
FACU
FAA
FA
EXP
EXH
EX
EWS
EWC
E.S.
ENT
ENCL
EMT
ELEV
TRANSFORMER
WEATHERPROOF
WATER HEATER
WIRE GUARD
WITH
VOLT AMPERE
VOLT
UNIT HEATER
UNDERGROUND
TYPICAL
TELEVISION
THERMOSTAT
THROUGH
TELEPHONE
TELECOMMUNICATIONS ROOM
TEMPERATURE CONTROL PANEL
SWITCHBOARD
SUITABLE FOR USE AS SERVICE EQUIP.
STRUCTURAL
SOLID STATE STARTER
SINGLE POINT CONNECTION
SERVICE ENTRANCE
RIGID STEEL (CONDUIT)
RIGID NONMETALLIC CONDUIT
RIGID METAL CONDUIT
REFERENCE GROUND POINT
POLYVINYL-CHLORIDE (CONDUIT)
ELECTRICAL ABBREVIATIONS
NTS NOT TO SCALE
LC-XX LIGHTING CONTROL SCHEDULE NOTE
DEDUCT ALTERNATE #1: REMOVE B407 NORTH SWING SPACE.
DEDUCT ALTERNATE #2: REMOVE B407 SOUTH SWING SPACE, BATHROOM REFRESH, AND IT CLOSET
INFRASTRUCTURE FROM PROJECT.
DEDUCT ALTERNATE #3: REMOVE SEALED BUBBLE WALL FOUNTAIN IN WAITING ROOM 1082 FROM PROJECT.
DEDUCT ALTERNATE #4: REBUILD (E) AHU RATHER THAN INSTALL A NEW ONE.
DEDUCT ALTERNATE #5: REMOVE EXTERIOR ENTRANCE CANOPY AT STAFF LOUNGE 1102.
DEDUCTIVE ALTERNATE:
GFCI RECEPTACLE DEVICE ON EMERGENCY CIRCUIT
GENERAL ELECTRICAL DEMOLITION NOTES:
A. DEMOLISH AND EXTEND EXISTING ELECTRICAL WORK AS INDICATED ON DRAWINGS, UNDER PROVISIONS OF DIVISION 01, AND SPEC SECTION 26 0500.
B. WHERE NOTED, EQUIPMENT REMOVED AND NOT NOTED AS SALVAGE FOR REUSE SHALL BE REMOVED FROM THIS JOB SITE AND LEGALLY DISPOSED OF BY ELECTRICAL CONTRACTOR.
C. MATERIALS AND EQUIPMENT INDICATED TO BE SALVAGED: REMOVE, DEMOUNT, DISCONNECT, AND DELIVER SAME TO A LOCATION DESIGNATED FOR STORAGE. LEAVE IN GOOD CONDITION AND STORE IN ORDERLY MANNER.
D. ALL EQUIPMENT TO BE SALVAGED SHALL BE CHECKED FOR DAMAGE AND CLEANED PRIOR TO REINSTALLATION.
E. REMOVE, RELOCATE, AND EXTEND EXISTING INSTALLATIONS TO ACCOMMODATE NEW CONSTRUCTION. CONTRACTOR SHALL REVIEW ALL ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS FOR EXTENT OF WORK.
F. REMOVE ALL ABANDONED CONDUIT, UNLESS INDICATED TO REMAIN FOR RE-USE OR FUTURE WORK, INCLUDING ABANDONED CONDUIT EXPOSED DURING DEMOLITION AND LOCATED ABOVE ACCESSIBLE CEILINGS. CUT CONCEALED ABANDONED CONDUIT FLUSH WITH WALLS AND
FLOORS THAT ARE INDICATED TO REMAIN.
G. ALL ELECTRICAL EQUIPMENT SHOWN DASHED ON DEMOLITION DRAWINGS SHALL BE REMOVED COMPLETE BY THE ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. EQUIPMENT SHALL BE REMOVED COMPLETE WITH ALL ASSOCIATED BACK BOXES, CONDUIT, CIRCUITRY, ETC.
H. PROVIDE APPROPRIATE BLANK COVER FOR ABANDONED BOXES WHICH ARE NOT REMOVED.
I. DISCONNECT AND REMOVE LUMINAIRES COMPLETE INCLUDING BRACKETS, STEMS, HANGERS, AND OTHER ACCESSORIES AS INDICATED. COORDINATE EXTENT OF CEILING DEMOLITION WITH GENERAL CONTRACTOR, AND MECHANICAL CONTRACTOR.
J. NO EXISTING WIRING REMOVED SHALL BE REUSED. PROVIDE ALL NEW CONDUCTORS AS SPECIFIED AND INDICATED ON DRAWINGS.
K. CONDUIT AND BACK BOXES REMOVED DURING DEMOLITION THAT ARE IN GOOD CONDITION MAY BE REUSED. HOWEVER DISCRETION SHOULD BE USED AS THE ENGINEER SHALL MAKE FINAL DETERMINATION AS TO THE CONDITION OF THIS EQUIPMENT. ANY EQUIPMENT NOT DETERMINED
TO BE IN GOOD CONDITION AND REUSED SHALL BE REPLACED AT THE CONTRACTOR'S EXPENSE.
L. REPAIR ADJACENT CONSTRUCTION & FINISHES DAMAGED DURING DEMOLITION & EXTENSION WORK. PATCH SURFACES IN ACCORDANCE WITH 26 0500.
M. MAINTAIN ACCESS TO EXISTING ELECTRICAL INSTALLATIONS WHICH REMAIN ACTIVE. MODIFY INSTALLATION OR PROVIDE ACCESS DOOR UNIT AS APPROPRIATE.
N. WHERE WALLS, CEILINGS AND/OR FLOORS ARE TO BE REMOVED. REROUTE FEEDERS AND BRANCH CIRCUITS AS REQUIRED TO MAINTAIN CONTINUITY OF CIRCUITRY TO ALL ELECTRICAL EQUIPMENT NOT REMOVED.
O. EXTEND EXISTING INSTALLATIONS USING MATERIALS AND METHODS COMPATIBLE WITH EXISTING ELECTRICAL INSTALLATIONS, AS SPECIFIED AND IN COMPLIANCE WITH CURRENT CODES.
P. THESE DRAWINGS ARE A REPRESENTATION OF EXISTING CONDITIONS AND DO NOT NECESSARILY INDICATE ALL ELECTRICAL EQUIPMENT TO BE REMOVED OR TO REMAIN INTACT. IT IS THE ELECTRICAL CONTRACTORS RESPONSIBILITY TO EVALUATE ALL CONDITIONS AND PROVIDE
DEMOLITION IN ACCORDANCE WITH THE OWNER.
Q. SEE SPEC SECTION 26 0500.
GENERAL ELECTRICAL NOTES:
A. LABEL ALL RECEPTACLES PLATES AS DESCRIBED IN SPEC. SECTION IDENTIFICATION FOR ELECTRICAL SYSTEMS. INCLUDE LABELING ON BACK OF DEVICE PLATE W/ PERMANENT INK.
B. LABEL ALL ADDRESSABLE FIRE ALARM DEVICES AS DESCRIBED IN SPEC. SECTION IDENTIFICATION FOR ELECTRICAL SYSTEMS.
C. LABEL ALL PANELBOARDS AS DESCRIBED IN SPEC. SECTION IDENTIFICATION FOR ELECTRICAL SYSTEMS.
D. PROVIDE ARC FLASH LABELS AT ALL NEW EQUIPMENT PER SPEC. SECTION IDENTIFICATION FOR ELECTRICAL SYSTEMS.
E. RECEPTACLE CIRCUITING: PROVIDE A MINIMUM OF ONE 4" SQUARE 2-1/8" DEEP JUNCTION BOX AT THE ACCESSIBLE CEILING IN EACH ROOM.
F. CONDUIT FITTINGS SHALL BE STEEL WITH SET SCREWS AND INSULATED THROATS. USE WATERTIGHT FITTINGS IN WET LOCATIONS ONLY.
G. ALL DEVICES MOUNTED AT ACCESSIBLE CEILINGS SHALL BE CONNECTED FROM A JUNCTION BOX WITH FLEXIBLE METAL CONDUIT.
H. ALL FIRE ALARM CONDUIT SHALL BE RED.
I. MAKE CONNECTIONS TO VIBRATING EQUIPMENT (INCLUDING MOTORS) USING FLEXIBLE CONDUIT WITH STRANDED CONDUCTORS.
J. MULTI-WIRE BRANCH CIRCUITS SHALL NOT BE ACCEPTABLE. PULL DEDICATED NEUTRAL CONDUCTOR IDENTIFIED WITH TRACER WIRE, COLOR TO MATCH PHASE CONDUCTOR.
K. NEUTRAL CONDUCTOR SIZE SHALL MATCH PHASE CONDUCTORS.
L. PROVIDE GROUND CONDUCTOR IN ALL FEEDERS & BRANCH CIRCUITS. SEE SPEC. SECTION GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS.
M. COLOR OF SWITCH LEG CONDUCTORS SHALL MATCH PHASE CONDUCTORS AND BE IDENTIFIED WITH COLORED TAPE. THREE AND FOUR WAY SWITCH "TRAVELERS" SHALL BE PINK OR PURPLE.
N. DO NOT INSTALL FLUSH MOUNTING BOX BACK-TO-BACK IN WALLS; PROVIDE MINIMUM 6 INCHES SEPARATION. PROVIDE MINIMUM 24 INCHES SEPARATION IN ACOUSTIC RATED WALLS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMP
321 4 5 6 7 8 9 10
ARCHITECT/ENGINEER OF RECORD
A/E:
CONSULTANT
C&S Engineers, Inc.
2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com
Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com
Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com
B
IM
/6
-3
B
E x p a n d
R e lo c a te
U rg e n t
C a re A n d
R e n o v a te s t F lo o r P a ti e n t C a re
/6
-3
.4
.M
E P
.r v t
/1
/2
:4
:4
P
M
E-000
ELECTRICAL ABBREVIATIONS AND
SYMBOLS
Expand and Renovate B400 for
Urgent and Primary Care
500 E Veterans St, Tomah, WI 54660
676-19-327
400/407
05/20/2021 A.NELSON T.INGLE
TRIPLE C - THE A&E GROUP
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
ISSUED FOR
CONSTRUCTION
ELECTRICAL SHEET INDEX
E-000 ELECTRICAL ABBREVIATIONS AND SYMBOLS
ED101 B400 - LEVEL 1 - ELECTRICAL DEMOLITION PLAN
ED102 B400 - LEVEL 2 - ELECTRICAL DEMOLITION PLAN
ED103-407 B407 - LEVEL 3 - ELECTRICAL DEMOLITION PLAN
EF101 B400 - LEVEL 1 - FIRE ALARM DEMOLITION PLAN
EF102 B400 - LEVEL 2 - FIRE ALARM DEMOLITION PLAN
EF103-407 B407 - LEVEL 3 - FIRE ALARM DEMOLITION PLAN
EL101 B400 - LEVEL 1 - LIGHTING PLAN
EL102 B400 - LEVEL 2 - LIGHTING PLAN
EL103-407 B407 - LEVEL 3 - LIGHTING PLAN
EL111 B400 - LEVEL 1 - LIGHTING CALCS
EL112 B400 - LEVEL 2 - LIGHTING CALCS
EL113-407 B407 - LEVEL 3 - LIGHTING CALCS
EP101 B400 - LEVEL 1 - POWER PLAN
EP102 B400 - LEVEL 2 - POWER PLAN
EP103-407 B407 - LEVEL 3 - POWER PLAN
EY101 B400 - LEVEL 1 - SPECIAL SYSTEMS PLAN
EY102 B400 - LEVEL 2 - SPECIAL SYSTEMS PLAN
EY103-407 B407 - LEVEL 3 - SPECIAL SYSTEMS PLAN
EF201 B400 - LEVEL 1 - FIRE ALARM PLAN
EF202 B400 - LEVEL 2 - FIRE ALARM PLAN
EF203-407 B407 - LEVEL 3 - FIRE ALARM PLAN
E-501 ELECTRICAL DETAILS
E-601 B400 ELECTRICAL DIAGRAMS
E-602 B400 ELECTRICAL DIAGRAMS
E-700 ELECTRICAL SCHEDULES
TELECOMMUNICATIONS
ROOMS
286443 TELECOMMUNICATIONS ROOMS 1043, 4010E, AND 3060 1) HAVE NO
GROUNDING FROM IT EQUIPMENT TO BUILDING GROUND, INSTALL
BONDING STRAPS ON IT RACKS, TELEPHONE CABLING HOUSINGS,
AND CABLE TRAYS SUCH THAT THEY ARE GROUNDED TO BUILDING
GROUND.
TELECOMMUNICATIONS
ROOMS
286442 TELECOMMUNICATIONS ROOM 2060 1) HAVE NO GROUNDING FROM
IT EQUIPMENT TO BUILDING GROUND, INSTALL BONDING STRAPS
ON IT RACKS, TELEPHONE CABLING HOUSINGS, AND CABLE TRAYS
SUCH THAT THEY ARE GROUNDED TO BUILDING GROUND. 2) HAVE
ABANDONED CABLING; REMOVE ABANDONED CABLING TO COMPLY
WITH CODE.
TELECOMMUNICATIONS
ROOMS
286441 ALL OF THE TELECOMMUNICATIONS ROOMS ARE TOO SMALL,
EXPAND ROOMS OR RELOCATE TO LOCATIONS THAT CONFORM TO
REQUIREMENTS OUTLINED IN VA SPACE PLANNING CRITERIA
CHAPTER 232 AND OIT DESIGN GUIDE SECTION 4 - 84.
INFORMATION
TECHNOLOGY
REC
NO
DESCRIPTION
SECONDARY DIST. 295171 CORRECT DEFICIENCIES FROM EATON STUDIES REPORT
COMPLETED IN SEPTEMBER 2012. EATON REPORT HAS
RECOMMENDED NEW SETTINGS FOR ADJUSTABLE LOW VOLTAGE
TRIP AND THERMAL MAGNETIC CIRCUIT BREAKERS IN ORDER TO
IMPROVE PROTECTION FOR PERSONNEL AND EQUIPMENT. FOR
DETAIL, REFER TO TABLE 4.4 - TCC PLOTS, PAGES 4-49 TO 4-58.
FIRE ALARM 111163 NEW FIRE ALARM PANEL AND DEVICES WERE INSTALLED IN 1999.
WIRING ON THE 1ST AND 2ND FLOORS HAS EXCEEDED ITS LIFE
EXPECTANCY AND SHOULD BE REPLACED.
PENDING TOTALS: NEW AIR HANDLER SERVING THE LAB AREA IS NOT BACKED UP ON
EMERGENCY POWER AS REQUIRED BY NFPA AND VA
REQUIREMENTS. RE-ROUTE FEEDER FROM NORMAL PANEL TO
EQUIPMENT-BRANCH PANEL.
ELECTRICAL REC
NO
DESCRIPTION
BUILDING 400 FCA REPORT
DISCLAIMER: THESE ITEMS HAVE BEEN DETERMINED TO HAVE REACHED THEIR END OF LIFE
USEFULNESS. THIS SCOPE OF WORK CONTRACT DID NOT ALLOCATE FUNDING FOR THE BELOW
MENTIONED DEFICIENCIES. THE FOLLOWING INFORMATION WAS RECEIVED FROM THE OWNER'S...
Revisions: Date:
ARCHITECT/ENGINEER OF RECORD
A/E:
CONSULTANT
C&S Engineers, Inc.
2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com
Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com
Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com
TRIPLE C - THE A&E GROUP
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
48553 5/20/2021 Anthony R. Nelson
CCTV
C C
T V
J
NCP
XXX
C C
T V
J C
XX
C C
TV
J
B
J
J
J
E
S
S
S
S
S S
S
S
S
S S
S
S
S S
S
S
S
S
S
S
SS
S
S
S
S S N
N
N
N
N
N
N N N
N
N
N
S
N
N
N
S
N
N
N
N
N
N
N
N
A A
AA
N
N
N
N
N
S
SS
C
S
SM
S
1 2 3 4 5 6 6.1 7 7.8 8 9 9.1 9.9 10 11 11.2 12 13 14 18171615
M.3
M
L
K.3
K
J.4
J.3
J
I.5
I.2
I
H.1
H
G
F.1
F
E
D
C
B
A
ICE
INTERCOMM
PANIC
NC PB
SCL
E C
B -L
S
E C
B -E
Q
ECB-CR
REMOTE
GENERATOR PANEL
DP-CR(480)
DP-CR(208)
T-CR
ATS(208)CR
ATS-LS
ATS(480)CR
T-EQ
DP-208-EQ
ATS-EQ
MSB(208)
LOAD CENTER NP-3-1
CP-4-1
NP-2-1
CP-2-1
CP-3-1
ELEVATOR PANEL
NVP-1
MDP(480)
WIREWAY
PULLBOX PULLBOX
EX NP-1-1
EX CP-6-1EX NP-1-1
EX LS-2-1
EX CP 6-11
EX EF-4
EX EF-2
DATA RACKS
EX EF-3
EX OHD
EX
CIRC
PUMP
EX AHU
EX
EXHAUST
FAN
EX DO (E)UH
EX LS-1-1
EX CP-5-1
EX NP-4-1
EX CP-7-1
EX CP-1-1
EX DP-480-EQ
EXAM
1027 EXAM
EXAM
OFFICE
OFFICE
OFFICE
OFFICE
EXAM
OFFICE
OFFICE
DIRTY
UTILTIY
OFFICE
WAITING
NURSE STATION
OFFICE
1011 EXAM
CONFERENCE
EXAM
EXAM
EXAM
OFFICE
OFFICE
WOMEN VISITOR TOILET
TLT
MECH
IT
OFFICE
1033 OFFICE
1035 OFFICE
EXAM
STAIR
WAITING / CIRCULATION
EXAM
EXAM
EXAM
NURSE STATION
EXAM
EXAM
WOMEN TLT
EXAM
EXAM
OFFICE
STORAGE
1096A
STAFF TOILET
STAFF
TOILET
AMBULANCE GARAGE
IT
1051B
ELECT
1051A
CLEAN STORAGE
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMP
321 4 5 6 7 8 9 10
GENERAL NOTES
KEY PLAN
KEYNOTES
AREA A
B400 KEY PLAN
AREA B
AREA
A1
AREA C
ARCHITECT/ENGINEER OF RECORD
A/E:
CONSULTANT
C&S Engineers, Inc.
2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com
Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com
Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com
B
IM
/6
-3
B
E x p a n d
R e lo c a te
U rg e n t
C a re A n d
R e n o v a te s t F lo o r P a ti e n t C a re
/6
-3
.4
.M
E P
.r v t
/1
/2
:4
:3
A
M
ED101
B400 - LEVEL 1 - ELECTRICAL
DEMOLITION PLAN
Expand and Renovate B400 for
Urgent and Primary Care
500 E Veterans St, Tomah, WI 54660
676-19-327
400/407
05/20/2021 A.BARTSCH T.INGLE
TRIPLE C - THE A&E GROUP
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
ISSUED FOR
CONSTRUCTION
SCALE: 1/8" = 1'-0"
B400 LEVEL 1 FLOOR PLAN - ELECTRICAL DEMOLITION
A. REMOVE EXISTING ELECTRICAL DEVICES, EQUIPMENT, BRANCH CIRCUITS
AND FEEDERS IN THEIR ENTIRETY BACK TO THEIR POINT OF ORIGIN UNLESS
OTHERWISE INDICATED. TURN OFF AND LABEL CIRCUIT BREAKERS AS
SPARES FOR NEW WORK.
B. QUANTITY AND LOCATION OF DEVICES SHOWN ON PLANS ARE
APPROXIMATE. FIELD VERIFY DEVICES AND LOCATIONS.
C. PROTECT EXISTING-TO-REMAIN CEILING, FLOORS, WALLS AND PANELS.
D. SELECT DEMOLITION MAY BE REQUIRED FOR NEW CONSTRUCTION AND MAY
NOT BE DELINEATED ON THIS DRAWING. CAREFULLY COORDINATE
DEMOLITION WITH NEW CONSTRUCTION (PARTITION AND REFLECTED
CEILING) PLANS TO VERIFY ACTUAL EXTENT OF DEMOLITION.
E. EXAMINE THE DRAWINGS OF OTHER TRADES AND BE FAMILIAR WITH THE
DEMOLITION REQUIRED BY OTHER TRADES. PERFORM INCIDENTAL
ELECTRICAL DEMOLITION WORK AND/OR RELOCATION REQUIRED TO
FACILITATE THE DEMOLITION WORK OF OTHER TRADES, WHETHER OR NOT
SPECIFICALLY INDICATED
F. RECYCLE OR DISPOSE MATERIALS OFF SITE AND INCLUDE ALL COSTS IN
BID. HANDLE ALL MATERIALS IN ACCORDANCE WITH LEED REQUIREMENTS,
ALL FEDERAL, STATE, AND LOCAL REGULATIONS,
G. PROVIDE BLANK COVER PLATES WHERE DEVICES ARE REMOVED BUT
EXISTING WALLS REMAIN INTACT.
H. WHERE EXISTING BUILDING SERVICES AND/OR EQUIPMENT THAT IS TO
REMAIN IN USE ARE REQUIRED TO BE SHUT DOWN COORDINATE WITH THE
OWNER'S REPRESENTATIVE. , INCLUDE ALL ASSOCIATED OVERTIME COSTS
TO PERFORM THIS WORK DURING WEEKENDS AND EVENINGS. INCLUDE ALL
COSTS FOR PROVIDING TEMPORARY POWER WHERE SHUT DOWN MUST
OCCUR FOR PERIODS LONGER THAN THESE HOURS. COORDINATE
ELECTRICAL SHUT DOWNS WITH THE OWNER ONE WEEK PRIOR TO SHUT
DOWN.
I. PROVIDE NEW TYPED DIRECTORIES FOR PANELS AFFECTED BY THIS
ALTERATION.
J. REMOVE ELECTRICAL EQUIPMENT INDICATED WITH HEAVY WEIGHT DASHED
LINES OR INDICATED WITH KEYNOTES.
K. PROVIDE CODE-COMPLIANT SUPPORT TO EXISTING-TO-REMAIN
UNSUPPORTED CONDUITS AND BOXES WHERE CEILINGS ARE TO BE
REMOVED. RE-ROUTE BRANCH CIRCUITS AND RELOCATE JUNCTION BOXES
AS REQUIRED TO FACILITATE INSTALLATION OF NEW EQUIPMENT AND
SYSTEMS IN CEILING SPACES.
L. MAINTAIN ELECTRICAL SERVICE TO LIGHTING FIXTURES AND DEVICES THAT
ARE TO REMAIN. EXTEND CONDUIT AND WIRE AS REQUIRED WHERE
DEMOLITION WORK AFFECTS ELECTRICAL SERVICE TO DOWNSTREAM
DEVICES THAT ARE TO REMAIN.
M. COORDINATE DEMOLITION AND NEW WORK AS TO NOT REMOVE SYSTEMS,
DEVICES, AND/OR ACCESSORIES NECESSARY FOR AREAS IN LATER
PHASES.
1 EXISTING DOOR ACCESS PANEL FOR URGENT CARE
AND AMBULANCE BAY SHALL BE DISCONNECTED AND
STORED DURING DEMOLITION FOR REINSTALLATION.
2 EXISTING UNDERCABINET LIGHTING TO BE
DEMOLISHED.
3 REMOVE PANELBOARD AND FEEDER TO BELOW
FLOOR, EXISTING FEEDER TO REMAIN AND TO BE
EXTENDED TO NEW LOCATION.
4 REMOVE EXISTING DATA RACK AND ASSOCIATED
DATA CABLES. EXISTING DATA JACKS TO REMAIN
SHALL BE REFED FROM THE MDF.
5 DISCONNECT POWER TO EQUIPMENT BEING
REMOVED, RETAIN BRANCH CIRCUIT FOR USE IN NEW
WORK.
6 DISCONNECT POWER TO EQUIPMENT BEING
REMOVED. REMOVE WIRING BACK TO SOURCE,
REMOVE ACCESSIBLE CONDUIT.
7 EXISTING EXTERIOR WALL PACK SHALL BE
DEMOLISHED. PRESERVE EXISTING WIRING AND
CONTROL CONNECTIONS FOR REROUTING TO NEW
EXTERIOR WALL PACK LOCATION.
8 EXISTING BOGEN GS150D PA AMPLIFIER.
Revisions: Date:
ARCHITECT/ENGINEER OF RECORD
A/E:
CONSULTANT
C&S Engineers, Inc.
2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com
Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com
Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com
TRIPLE C - THE A&E GROUP
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
48553 5/20/2021 Anthony R. Nelson
Checked
A.NELSON
SS
S S
S
S S
J
A
B
J
SS
S
SS
J
S S
S
SS
J
S
C
S
S
S
S S
J
S
S
1 2 3 4 5 6 6.1 7 7.8 8 9 9.1 9.9 10 11 11.2 12 13 14 18171615
M.3
M
L
K.3
K
J.4
J.3
J
I.5
I.2
I
H.1
H
G
F.1
F
E
D
C
B
A
EX CP-6-2.1
EX CP-6-2
EX 4 CP-2-2
EX CP-2-2 EX CP-1-2
EX NP-1-2
EX LS1-2
EX NC
EX WAP
OFFICE
UNOCCUPIED
CLEAN UTILITY
ELEC.
LAB
MECHANICAL
OFFICE
2015A
TOILET, STAFF
2030A
UTILITY ROOM, SOILED
TOILET
LOCKER ROOM
LAB
TREATMENT ROOM
EXAM/
TREATMENT
ROOM
EXAM/ TREATMENT ROOM
TREATMENT ROOM
EXAM/TREATMENT ROOM
TREATMENT ROOM
STAIR
S9
TELE
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMP
321 4 5 6 7 8 9 10
GENERAL NOTES
KEY PLAN
KEYNOTES
AREA A
B400 KEY PLAN
AREA B
AREA
A1
AREA C
ARCHITECT/ENGINEER OF RECORD
A/E:
CONSULTANT
C&S Engineers, Inc.
2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com
Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com
Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com
B
IM
/6
-3
B
E x p a n d
R e lo c a te
U rg e n t
C a re A n d
R e n o v a te s t F lo o r P a ti e n t C a re
/6
-3
.4
.M
E P
.r v t
/1
/2
:4
:3
A
M
ED102
B400 - LEVEL 2 - ELECTRICAL
DEMOLITION PLAN
Expand and Renovate B400 for
Urgent and Primary Care
500 E Veterans St, Tomah, WI 54660
676-19-327
400/407
05/20/2021 A.BARTSCH T.INGLE
TRIPLE C - THE A&E GROUP
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
ISSUED FOR
CONSTRUCTION
SCALE: 1/8" = 1'-0"
B400 LEVEL 2 FLOOR PLAN - ELECTRICAL DEMOLITION
A. REMOVE EXISTING ELECTRICAL DEVICES, EQUIPMENT, BRANCH CIRCUITS
AND FEEDERS IN THEIR ENTIRETY BACK TO THEIR POINT OF ORIGIN UNLESS
OTHERWISE INDICATED. TURN OFF AND LABEL CIRCUIT BREAKERS AS
SPARES FOR NEW WORK.
B. QUANTITY AND LOCATION OF DEVICES SHOWN ON PLANS ARE
APPROXIMATE. FIELD VERIFY DEVICES AND LOCATIONS.
C. PROTECT EXISTING-TO-REMAIN CEILING, FLOORS, WALLS AND PANELS.
D. SELECT DEMOLITION MAY BE REQUIRED FOR NEW CONSTRUCTION AND MAY
NOT BE DELINEATED ON THIS DRAWING. CAREFULLY COORDINATE
DEMOLITION WITH NEW CONSTRUCTION (PARTITION AND REFLECTED
CEILING) PLANS TO VERIFY ACTUAL EXTENT OF DEMOLITION.
E. EXAMINE THE DRAWINGS OF OTHER TRADES AND BE FAMILIAR WITH THE
DEMOLITION REQUIRED BY OTHER TRADES. PERFORM INCIDENTAL
ELECTRICAL DEMOLITION WORK AND/OR RELOCATION REQUIRED TO
FACILITATE THE DEMOLITION WORK OF OTHER TRADES, WHETHER OR NOT
SPECIFICALLY INDICATED
F. RECYCLE OR DISPOSE MATERIALS OFF SITE AND INCLUDE ALL COSTS IN
BID. HANDLE ALL MATERIALS IN ACCORDANCE WITH LEED REQUIREMENTS,
ALL FEDERAL, STATE, AND LOCAL REGULATIONS,
G. PROVIDE BLANK COVER PLATES WHERE DEVICES ARE REMOVED BUT
EXISTING WALLS REMAIN INTACT.
H. WHERE EXISTING BUILDING SERVICES AND/OR EQUIPMENT THAT IS TO
REMAIN IN USE ARE REQUIRED TO BE SHUT DOWN COORDINATE WITH THE
OWNER'S REPRESENTATIVE. , INCLUDE ALL ASSOCIATED OVERTIME COSTS
TO PERFORM THIS WORK DURING WEEKENDS AND EVENINGS. INCLUDE ALL
COSTS FOR PROVIDING TEMPORARY POWER WHERE SHUT DOWN MUST
OCCUR FOR PERIODS LONGER THAN THESE HOURS. COORDINATE
ELECTRICAL SHUT DOWNS WITH THE OWNER ONE WEEK PRIOR TO SHUT
DOWN.
I. PROVIDE NEW TYPED DIRECTORIES FOR PANELS AFFECTED BY THIS
ALTERATION.
J. REMOVE ELECTRICAL EQUIPMENT INDICATED WITH HEAVY WEIGHT DASHED
LINES OR INDICATED WITH KEYNOTES.
K. PROVIDE CODE-COMPLIANT SUPPORT TO EXISTING-TO-REMAIN
UNSUPPORTED CONDUITS AND BOXES WHERE CEILINGS ARE TO BE
REMOVED. RE-ROUTE BRANCH CIRCUITS AND RELOCATE JUNCTION BOXES
AS REQUIRED TO FACILITATE INSTALLATION OF NEW EQUIPMENT AND
SYSTEMS IN CEILING SPACES.
L. MAINTAIN ELECTRICAL SERVICE TO LIGHTING FIXTURES AND DEVICES THAT
ARE TO REMAIN. EXTEND CONDUIT AND WIRE AS REQUIRED WHERE
DEMOLITION WORK AFFECTS ELECTRICAL SERVICE TO DOWNSTREAM
DEVICES THAT ARE TO REMAIN.
1 EXISTING AIR COMPRESSOR TO REMAIN.
2 DISCONNECTED AIR DRYER TO REMAIN.
3 EXISTING AIR HANDLING UNIT TO REMAIN.
4 EXISTING DATA RACK FEEDING SECOND FLOOR.
ADJUST EXISTING PATCH PANEL MOUNTING AS
REQUIRED TO ALLOW FOR NEW PATCH PANELS.
Revisions: Date:
ARCHITECT/ENGINEER OF RECORD
A/E:
CONSULTANT
C&S Engineers, Inc.
2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com
Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com
Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com
TRIPLE C - THE A&E GROUP
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
48553 5/20/2021 Anthony R. Nelson
J J
J J
J J
J
J
N
N
J
S
VUV-2790
VUV-2776
EX BLANK
EX BLANK EX BLANK
NP2-3
LS-2-3
CP2-3
407.A
407.B1
407.C1
407.D1
407.E
407.F
407.G1
407.H
407.I
407.J
407.K
407.L
407.M
407.N
407.14407.11 407.12.1407.12
407.9407.7
407.41407.4407.3407.21
J.39
J.40
J.41
407.H2
407.H1
407.13.1
EX CP3-3
EX CP1-3
EX LS1-3
EX NP1-3
EX 407 DATA RACK
OPEN OFFICE
ELECTRICAL
DATA CLOSET
3772A
OPEN OFFICE
MECH / ELEC
RESTROOM
RESTROOM
DEDUCT ALT 1:
REMOVE WORK
ASSOCIATED WITH
B407 NORTH.
DEDUCT ALT 2:
REMOVE WORK
ASSOCIATED WITH
B407 SOUTH.
DEDUCT ALT 2:
REMOVE WORK
ASSOCIATED WITH
B407 SOUTH.
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMP
321 4 5 6 7 8 9 10
GENERAL NOTES
B407 KEY PLAN
AREA A
KEY PLAN
ARCHITECT/ENGINEER OF RECORD
A/E:
CONSULTANT
C&S Engineers, Inc.
2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com
Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com
Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com
B
IM
/6
-3
B
E x p a n d
R e lo c a te
U rg e n t
C a re A n d
R e n o v a te s t F lo o r P a ti e n t C a re
/6
-3
.4
.M
E P
.r v t
/1
/2
:4
:3
A
M
ED103-407
B407 - LEVEL 3 - ELECTRICAL
DEMOLITION PLAN
Expand and Renovate B400 for
Urgent and Primary Care
500 E Veterans St, Tomah, WI 54660
676-19-327
400/407
05/20/2021 A.BARTSCH T.INGLE
TRIPLE C - THE A&E GROUP
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
ISSUED FOR
CONSTRUCTION
SCALE: 1/8" = 1'-0"
B407 LEVEL 3 FLOOR PLAN - ELECTRICAL DEMOLITION
A. REMOVE EXISTING ELECTRICAL DEVICES, EQUIPMENT, BRANCH CIRCUITS
AND FEEDERS IN THEIR ENTIRETY BACK TO THEIR POINT OF ORIGIN UNLESS
OTHERWISE INDICATED. TURN OFF AND LABEL CIRCUIT BREAKERS AS
SPARES FOR NEW WORK.
B. QUANTITY AND LOCATION OF DEVICES SHOWN ON PLANS ARE
APPROXIMATE. FIELD VERIFY DEVICES AND LOCATIONS.
C. PROTECT EXISTING-TO-REMAIN CEILING, FLOORS, WALLS AND PANELS.
D. SELECT DEMOLITION MAY BE REQUIRED FOR NEW CONSTRUCTION AND MAY
NOT BE DELINEATED ON THIS DRAWING. CAREFULLY COORDINATE
DEMOLITION WITH NEW CONSTRUCTION (PARTITION AND REFLECTED
CEILING) PLANS TO VERIFY ACTUAL EXTENT OF DEMOLITION.
E. EXAMINE THE DRAWINGS OF OTHER TRADES AND BE FAMILIAR WITH THE
DEMOLITION REQUIRED BY OTHER TRADES. PERFORM INCIDENTAL
ELECTRICAL DEMOLITION WORK AND/OR RELOCATION REQUIRED TO
FACILITATE THE DEMOLITION WORK OF OTHER TRADES, WHETHER OR NOT
SPECIFICALLY INDICATED
F. RECYCLE OR DISPOSE MATERIALS OFF SITE AND INCLUDE ALL COSTS IN
BID. HANDLE ALL MATERIALS IN ACCORDANCE WITH LEED REQUIREMENTS,
ALL FEDERAL, STATE, AND LOCAL REGULATIONS,
G. PROVIDE BLANK COVER PLATES WHERE DEVICES ARE REMOVED BUT
EXISTING WALLS REMAIN INTACT.
H. WHERE EXISTING BUILDING SERVICES AND/OR EQUIPMENT THAT IS TO
REMAIN IN USE ARE REQUIRED TO BE SHUT DOWN COORDINATE WITH THE
OWNER'S REPRESENTATIVE. , INCLUDE ALL ASSOCIATED OVERTIME COSTS
TO PERFORM THIS WORK DURING WEEKENDS AND EVENINGS. INCLUDE ALL
COSTS FOR PROVIDING TEMPORARY POWER WHERE SHUT DOWN MUST
OCCUR FOR PERIODS LONGER THAN THESE HOURS. COORDINATE
ELECTRICAL SHUT DOWNS WITH THE OWNER ONE WEEK PRIOR TO SHUT
DOWN.
I. PROVIDE NEW TYPED DIRECTORIES FOR PANELS AFFECTED BY THIS
ALTERATION.
J. REMOVE ELECTRICAL EQUIPMENT INDICATED WITH HEAVY WEIGHT DASHED
LINES OR INDICATED WITH KEYNOTES.
K. PROVIDE CODE-COMPLIANT SUPPORT TO EXISTING-TO-REMAIN
UNSUPPORTED CONDUITS AND BOXES WHERE CEILINGS ARE TO BE
REMOVED. RE-ROUTE BRANCH CIRCUITS AND RELOCATE JUNCTION BOXES
AS REQUIRED TO FACILITATE INSTALLATION OF NEW EQUIPMENT AND
SYSTEMS IN CEILING SPACES.
L. MAINTAIN ELECTRICAL SERVICE TO LIGHTING FIXTURES AND DEVICES THAT
ARE TO REMAIN. EXTEND CONDUIT AND WIRE AS REQUIRED WHERE
DEMOLITION WORK AFFECTS ELECTRICAL SERVICE TO DOWNSTREAM
DEVICES THAT ARE TO REMAIN.
Revisions: Date:
ARCHITECT/ENGINEER OF RECORD
A/E:
CONSULTANT
C&S Engineers, Inc.
2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com
Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com
Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com
TRIPLE C - THE A&E GROUP
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
48553 5/20/2021 Anthony R. Nelson
D
D
S
D
D
S
D
S
D
D
D
D
S D
S
S
D
S
D
D
D
DD
D
S
D
D
D
D
S
D
D
D
J
J
S
U
S
S
D
D
D
D
D
D
LC
LC
D
D
D
D
D
D D
D
D
D
D
D
D
D
D D
D
D
D D
A. ALIGN DEVICES VERTICALLY WHERE LIGHTING, POWER, AND SYSTEM
DEVICES WITH DIFFERENT MOUNTING HEIGHTS ARE INDICATED CLOSE TO
OTHER DEVICES.
B. REFER TO THE ARCHITECTURAL ELEVATION, DETAIL, AND REFLECTED
CEILING PLAN DRAWINGS FOR COORDINATION OF ELECTRICAL DEVICES.
C. CUTTING, DRILLING, AND/OR BORING THROUGH STRUCTURAL MEMBERS IS
NOT ACCEPTABLE.
D. PROVIDE FIRE RATED SEALS ON PENETRATIONS IN FIRE RATED FLOORS
AND WALLS. COORDINATE RATED LOCATIONS WITH LIFE SAFETY CODE
PLAN DRAWINGS.
E. PROVIDE INSULATED BUSHINGS FOR ROUGH-IN AND CONDUIT SLEEVE
LOCATIONS PRIOR TO INSTALLATION OF ANY CABLING.
F. BRANCH CIRCUITS CONDUCTOR LENGTHS FROM PANEL LONGER THAN 100’
FOR 120V AND 200' FOR 277V SHALL BE #10 OR LARGER FOR ENTIRE
LENGTH OF CIRCUIT FOR LINE, NEUTRAL, AND GROUND WIRES.
G. PROVIDE DEDICATED NEUTRAL FOR EACH MULTIWIRE BRANCH CIRCUIT
PHASE CONDUCTOR. PROVIDE DEDICATED NEUTRAL FOR EACH DIMMING
CIRCUIT.
H. DEVICES IN FINISHED AREAS ARE TO BE RECESSED WITHIN WALLS EXCEPT
WHERE REQUIRED TO BE SURFACE MOUNTED. IN UNFINISHED AREAS
(PLUMBING CHASES, JANITORS CLOSETS, ELECTRICAL ROOMS, AND
MECHANICAL ROOMS) DEVICES AND CONDUIT MAY BE SURFACE MOUNTED.
I. LIGHT SWITCHES SHALL BE MOUNTED ON LATCH SIDE OF DOOR, WITHIN 12"
OF DOOR/SIDELIGHT FRAMING, UNLESS NOTED OTHERWISE. LIGHT
SWITCHES INSTALLED ADJACENT TO DOOR SWINGS SHALL BE MOUNTED
CLEAR OF DOOR SWING AND WITHIN 12" OF DOOR IN OPEN POSITION.
COORDINATE LOCATION WITH OTHER WALL DEVICES.
J. COORDINATE LUMINAIRE LOCATIONS WITH STRUCTURAL AND MECHANICAL
TRADES PRIOR TO INSTALLATION. COORDINATE MOUNTING HEIGHTS AND
LOCATIONS OF LUMINAIRES IN MECHANICAL ROOMS WITH DUCTS, PIPES,
AND EQUIPMENT. MOUNT LUMINAIRES BELOW DUCTS AND PIPES AND AVOID
MOUNTING LUMINAIRES OVER EQUIPMENT. SUPPORT LUMINAIRES
INDEPENDENTLY OF DUCTS, PIPES, AND EQUIPMENT.
K. VERIFY OCCUPANCY SENSOR DEVICE LAYOUT AND QUANTITIES FOR
COMPLETE AREA/ROOM COVERAGE WITH SENSOR MANUFACTURER PRIOR
TO ROUGH-IN.
L. COORDINATE CEILING TYPES, RECESS CONDITIONS, AND MOUNTING
HARDWARE REQUIRED PRIOR TO PURCHASE OF LUMINAIRES.
M. WIRING SHALL NOT FEED THROUGH FIXTURES EXCEPT TO SERVE
CONTINUOUS ROWS OF SIMILAR TYPE OF LUMINAIRES.
N. FOR EXISTING PANELS, CIRCUIT NUMBERS ARE FOR REFERENCE ONLY.
COORDINATE EXISTING PANEL CONFIGURATION. UTILIZE EXISTING DEMOED
CIRCUITS FEEDING THIS AREA. PROVIDE NEW, UPDATED, TYPED PANEL
INDEX FOR MODIFIED PANELS. UNUSED CIRCUIT BREAKERS SHALL BE
LISTED AS SPARE.
O. COORDINATE DEMOLITION AND NEW WORK AS TO NOT REMOVE SYSTEMS,
DEVICES, AND/OR ACCESSORIES NECESSARY FOR AREAS IN LATER
PHASES.
P. PROVIDE NON-METALLIC SURFACE RACEWAY FOR DEVICES MOUNTED ON
EXISTING SOLID WALLS. EXPOSED/SURFACE CONDUIT IS NOT ALLOWED.
1 2 3 4 5 6 6.1 7 7.8 8 9 9.1 9.9 10 11 11.2 12 13 14 18171615
M.3
M
L
K.3
K
J.4
J.3
J
I.5
I.2
I
H.1
H
G
F.1
F
E
D
C
B
A
LIGHTING CONTROL ZONE
LIGHTING CONTROL ZONE
LIGHTING CONTROL ZONE
LIGHTING CONTROL ZONE
CONF
CONSULT ROOM 2
CONSULT ROOM 1
CLEAN UTILITY
EXAM 10
CHAIR EXAM
1085b
EXAM 6
1083 ANTE ROOM
1108A
OFFICE
EXAM 8
ALCOVE
WHEELCHAIR ALCOVE
EQ. ALCOVE
EXAM 13 / CONSULT RM 3
EXAM 2
TEAM
WORK
STATIONS
WAITING
1032B
TEAM AREA
1101A
TEAM AREA
1086A
PATIENT TLT
TLT
1022B
STAFF TLT
1019B
MECH
STAFF
TOILET
1100B
BARIATRIC/
WOMENS
HEALTH
TLT
TLT
1104B
TLT/SHWR
EXAM 2 - NEGATIVE PRESS
1104A
MEDS
EXAM 4
EXAM 5 BARIATRIC/ WOMENS HEALTH
1100A
RECEPT CHECK IN/OUT
1032A
WEIGH AREA
MEDS
CORRIDOR
OC11
EXAM 12
FAMILY TLT
NURSE
MANAGER
OFFICE
OFFICE
CLEAN
SUPPLY
EXAM 7
SOILED UTILITY / SPD
CORRIDOR
OC13
EXAM 1
TLT
1108C
LOGISTICS STORAGE
AMBULANCE BAY
TELEHEALTH
TRIAGE
RECEPTION
1080C
TELEHEALTH
STOR
EXAM 7
CLEAN UTLITY
VESTIBULE
EXAM 9
STAFF LOUNGE
EXAM 1- NEGATIVE PRESS
1108B
WAITING
CORRIDOR
OC20
SOILED UTILITY
1099A
MENTAL
HEALTH
CORRIDOR
OC21
CORRIDOR
OC19
CORRIDOR
OC22
HALLWAY
OC14
EXAM 8
EXAM 11
LACTATION
IT
1051B
ELECT
1051A
HAC
LC-11
LC-10
LC-10
LC-5
LC-10
LC-9
LC-9
LC-6
LC-4
LC-9
LC-10
LC-10
LC-7
LC-8LC-8
LC-3
LC-3
LC-3
LC-3
LC-3
LC-3
LC-10
LC-5
LC-9
LC-10
LC-2
LC-5
LC-6
LC-10
LC-3
LC-11
LC-4
LC-5
LC-10
LC-5
LC-6
LC-10
LC-3
LC-5
LC-11
LC-9
LC-1
LC-11
LC-9
LC-10
LC-4
LC-10
LC-1
LC-6
LC-5
LC-9
LC-6
LC-6
LC-6
LC-2
LC-10
LC-10
LC-9
LC-5
EX ECB-EQ
EX REMOTE
GENERATOR PANEL
EX ATS-LS
EX ATS(480)CR
EX ATS-EQEX DP-LS
EX ATS(208)CR EX DP-LQ
EX DP-CR(480)
EX T-CR
EX DP-CR(208)
EX DP-208-EQ
EX T-EQ
EX ECB-LS
EX ECB-CR
EX LOAD CENTER
EX NP-3-1
EX MSB(208)
EX CP-3-1
EX ELEVATOR
PANEL
EX NVP-1
EX MDP(480)
EX CP-2-1
EX NP-2-1
EX CP-4-1
EX DP-480-EQ
EX CP-6-1 EX NP-1-1
EX LS-2-1
B1
B1
B1
B1
B1B1B1
A1
A1
B1 B1
A1
C1
B1
A1 A3
B1
A1 A1
A1
A1
B1 B1
A1
B1
A3
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
E1
E1
A1 A1
B1 B1
B1
B1
B1 B1
B1
A3
A1
A1
A3
A1
A3
B1
B1 B1
B1
A1
A3
A3
A1
A1
A1
B1 B1 B1 B1
B1 B1 B1
B1
D1
D1
D1
A1
A3
A1
A3
A1
A3
A3
A1
A1
A1
A2 A4
A1
B1B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1 B1
B1B1
B1 B1
B1
B1
A2 A4
A1
A3
A1
B1
A1
A1 A3
A3
A1
A1 A3
A3
D1
DP
DP
F1
F1
F1
H1
B1
D1
DT
D1
B1
B1
D1
D1
D2
D2
D2
B1 B1 z1 z1 z1
D1 D1
D1
B1
E1
E1
E1
D2
A1
A3
E1
E1
E2
B1
D1 D1
D1
E1
H1 H1
A5
A5
B2 B2
D2
D2
A5
DT
CP-8-1-36
CP-8-1-36
CP-8-1-36
CP-8-1-36
CP-8-1-34
CP-8-1-34 CP-8-1-34
CP-8-1-34
CP-8-1-34
CP-8-1-34
CP-8-1-34
CP-8-1-34 LS-2-1-1
CP-8-1-34CP-8-1-34CP-8-1-34
CP-8-1-34
CP-8-1-34
CP-8-1-34
CP-8-1-34
CP-8-1-34
CP-8-1-35
CP-8-1-35 CP-8-1-35
CP-8-1-35
CP-8-1-35
CP-8-1-35
CP-8-1-35
CP-8-1-35
CP-8-1-35
CP-8-1-35
CP-8-1-35CP-8-1-35
CP-8-1-35
CP-8-1-35
CP-8-1-35
CP-8-1-35
CP-8-1-35
CP-8-1-35
CP-8-1-35
CP-8-1-35
CP-8-1-35
CP-8-1-37CP-8-1-37 LS-2-1-1
LS-2-1-1
LS-2-1-1
LS-2-1-1
LS-2-1-1
LS-2-1-1
LS-2-1-1
LS-2-1-1
LS-2-1-1
LS-2-1-1
LS-2-1-1
CP-8-1-37
LS-2-1-1
CP-8-1-37 CP-8-1-37
CP-8-1-37
CP-8-1-37
CP-8-1-37
CP-8-1-37
CP-8-1-37
CP-8-1-37
CP-8-1-37
LS-2-1-3
LS-2-1-3
LS-2-1-3
LS-2-1-3
LS-2-1-3
LS-2-1-3
LS-2-1-3
LS-2-1-3
LS-2-1-3
LS-2-1-3
CP-1-1-40
CP-1-1-40 CP-1-1-40
CP-1-1-40
CP-1-1-40
CP-1-1-40
CP-1-1-40
CP-1-1-40
CP-1-1-40
CP-1-1-40
CP-1-1-40
CP-1-1-40 CP-1-1-40
CP-1-1-40
CP-1-1-40 CP-1-1-40
CP-1-1-40 CP-1-1-40
CP-1-1-40CP-1-1-40
CP-1-1-40CP-1-1-40
CP-1-1-40
CP-1-1-40
CP-1-1-40CP-1-1-40
CP-1-1-40 CP-1-1-40
CP-1-1-40CP-1-1-40
LS-2-1-3
LS-2-1-3
CP-1-1-41
CP-1-1-41
CP-1-1-41 CP-1-1-41
CP-1-1-41
CP-1-1-41CP-1-1-41
CP-1-1-41 CP-1-1-41
CP-1-1-41
CP-1-1-41
CP-1-1-42
CP-1-1-41
CP-1-1-41
CP-1-1-41
CP-1-1-41
CP-1-1-41
CP-1-1-41
CP-1-1-41
CP-1-1-41
CP-1-1-41CP-1-1-41
CP-1-1-41
CP-1-1-41
CP-1-1-41
CP-1-1-41
CP-1-1-41
CP-1-1-41
CP-1-1-41
CP-1-1-42
CP-1-1-42
CP-1-1-42CP-1-1-42
CP-1-1-42
CP-1-1-42
CP-1-1-42
CP-1-1-42
CP-1-1-42
CP-1-1-42
CP-1-1-42
CP-1-1-42
CP-1-1-42
CP-1-1-42
CP-1-1-42
CP-1-1-42
CP-1-1-42
CP-1-1-42
LS-2-1-3
CP-1-1-42 CP-1-1-42
CP-1-1-42
CP-1-1-42
CP-1-1-42
CP-1-1-42
CP-1-1-42
CP-1-1-42
CP-1-1-42
CP-1-1-42
CP-1-1-42
CP-1-1-42
CP-1-1-42
CP-1-1-42
CP-1-1-42
CP-1-1-42
CP-1-1-42
NL
NL
NL
NL
NL
NL
NL
NL
NL
NL
NL
NL
NL
NL
SL SL
SL SL
SL SL
CP-8-1-37
CP-8-1-37
CP-8-1-37 CP-8-1-37
CP-8-1-37
CP-8-1-37
b b ba a a
NL
a b
H1
CP-1-1-42
B2
CP-1-1-42
D2
CP-1-1-40
S1
CP-1-1-40
LC-5
S1
CP-1-1-40
S1
CP-1-1-40
CP-1-1
LC-2
S1
CP-1-1-42
S1
CP-8-1-35
LC-5
S1
CP-8-1-35
S1
CP-8-1-35
CP-8-1 NP-5-1
EX CP-5-1
CP-8-1-37
S2
CP-8-1-34
S1
CP-8-1-34
EX
EX
EX
EX
NP-1-1
A5
CP-8-1-34
LC-3
1099B
TLT
MENTAL
HEALTH
D2
CP-8-1-34
D1
CP-8-1-35
A3
A3
CP-8-1-34
CP-8-1-34
z2 z2 z2 z2 z2
CP-8-1-37
z3
F1
F1
CP-8-1-37
CP-8-1-37
z3 z3
C1
CP-8-1-34
EX NP-4-1
EX CP-7-1
E2
LS-2-1-1
LS-1-1
NL
E1
LS-2-1-1
DEDUCT
ALTERNATE #5:
EXTERIOR
EXTRANCE CANOPY.
z1 z2 z3 z1 z1 z1 z1z1z3 z3 z3 z2 z2 z2 z2 z2 z2 z2 z2z2 z2 z2
D1
LS-2-1-3
NL
ALTERNATE #5: REMOVE EXTERIOR ENTRANCE CANOPY
AT STAFF LOUNGE 1100.
A. PROVIDE CONNECTIONS FROM LIGHTING CIRCUITING
ROUGH-INS TO INTEGRAL CANOPY LIGHTING.
Z1
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMP
321 4 5 6 7 8 9 10
GENERAL NOTES
KEY PLAN
KEYNOTES
AREA A
B400 KEY PLAN
AREA B
AREA
A1
AREA C
ARCHITECT/ENGINEER OF RECORD
A/E:
CONSULTANT
C&S Engineers, Inc.
2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com
Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com
Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com
B
IM
/6
-3
B
E x p a n d
R e lo c a te
U rg e n t
C a re A n d
R e n o v a te s t F lo o r P a ti e n t C a re
/6
-3
.4
.M
E P
.r v t
/1
/2
:4
:1
A
M
EL101
B400 - LEVEL 1 - LIGHTING PLAN
Expand and Renovate B400 for
Urgent and Primary Care
500 E Veterans St, Tomah, WI 54660
676-19-327
400/407
05/20/2021 A.BARTSCH T.INGLE
TRIPLE C - THE A&E GROUP
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
ISSUED FOR
CONSTRUCTION
1 COORDINATE MOUNTING OF LUMINAIRES WITH
MECHANICAL DUCTWORK AND EQUIPMENT IN THIS
SPACE.
2 PROVIDE POWER AND CONTROLS ROUGH-IN TO
CANOPY UNDER BASE BID. EXTEND EXISTING
EXTERIOR LIGHTING CIRCUIT TO CANOPY ROUGH-IN
LOCATION. COORDINATE CONNECTION WITH CANOPY
INSTALLER.
3 PROVIDE 3-WAY DIMMER SWITCH FOR LOCAL
OVERRIDE OF LIGHTING CONTROL ZONE.
4 PROVIDE ROOM CONTROLLER EQUAL TO STEINEL DCS
CONTROLLER. ROOM CONTROLLER SHALL BE
PROGRAMMED WITH OWNER'S BAS DUSK-TO-DAWN
TIME SETTINGS. LOCAL PIR OCCUPANCY SENSORS
AND DIMMER WALL STATIONS SHALL BE WIRED
THROUGH ROOM CONTROLLER.
5 EXTEND/REFEED EXISTING WIRING FROM
DEMOLISHED EXTERIOR WALL PACK TO NEW
EXTERIOR WALL PACK LOCATION. FIXTURE MOUNTED
IDEALLY 8'-0" TO CENTER OF ROUGH-IN. CONCEAL
CONDUIT AS MUCH AS POSSIBLE. COORDINATE
MOUNTING WITH OWNER.
SCALE: 1/8" = 1'-0"
B400 LEVEL 1 FLOOR PLAN - LIGHTING
Revisions: Date:
ARCHITECT/ENGINEER OF RECORD
A/E:
CONSULTANT
C&S Engineers, Inc.
2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com
Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com
Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com
TRIPLE C - THE A&E GROUP
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
48553 5/20/2021 Anthony R. Nelson
D
D
D
D D
S
D
D
D
D S
D
DDD
D
D
D
LC
1 2 3 4 5 6 6.1 7 7.8 8 9 9.1 9.9 10 11 11.2 12 13 14 18171615
M.3
M
L
K.3
K
J.4
J.3
J
I.5
I.2
I
H.1
H
G
F.1
F
E
D
C
B
A
MECH
INFUSION ROOM
MECH
EXAM 1
CLEAN UTILITY - LOGISTICS
TLT
TEAM
WORK
AREA
MED EQUIPMENT STORAGE
EXAM 5
EXAM 3
EXAM 2
EXAM 4
CORRIDOR
OC22
CLEAN LINENS
SOILED UTILITY
A1
A3 A3
A1
B1
B1
B1
B1
B1
B1
B1
B1
A3
A1
A1
A3
B1
A1 A1
A3
A3
A1
D1 D1
B1
B1
B1 B1
B1
B1 B1
A1 A1
LIGHTING CONTROL ZONE
A3
E1 a b a a b b b
CP-1-2-17
CP-1-2-17CP-1-2-17
CP-1-2-17
CP-1-2-16
CP-1-2-16
CP-1-2-16
CP-1-2-16
CP-1-2-16
CP-1-2-16
CP-1-2-16
CP-1-2-16
CP-1-2-16
CP-1-2-16
CP-1-2-16
CP-1-2-16
CP-1-2-16 CP-1-2-16
CP-1-2-16
CP-1-2-16
CP-1-2-16
CP-1-2-16
CP-1-2-16
CP-1-2-16
CP-1-2-17
CP-1-2-16
LS1-2-1
LS1-2-1
LS1-2-1
LS1-2-1
LS1-2-1
CP-1-2-18
CP-1-2-18
CP-1-2-18
CP-1-2-18
B1
B1
CP-1-2-17
CP-1-2-17
NL
NL
NL
NL
d c b a a a d c b
B2
CP-1-2-18
EX
LC-7
LC-3
S1
CP-1-2-16LC-3
LC-10
LC-5
LC-10
LC-10
LC-9
LC-6
LC-9
LC-9
EX CP-2-2
EX CP-1-2
EX NP-1-2
EX CP-6-2.1
EX CP-6-2
EX 4 CP-2-2
SOILED
UTILITY
LC-5
A1
CP-1-2-18
LC-5
a,b,c,d
A. ALIGN DEVICES VERTICALLY WHERE LIGHTING, POWER, AND SYSTEM
DEVICES WITH DIFFERENT MOUNTING HEIGHTS ARE INDICATED CLOSE TO
OTHER DEVICES.
B. REFER TO THE ARCHITECTURAL ELEVATION, DETAIL, AND REFLECTED
CEILING PLAN DRAWINGS FOR COORDINATION OF ELECTRICAL DEVICES.
C. CUTTING, DRILLING, AND/OR BORING THROUGH STRUCTURAL MEMBERS IS
NOT ACCEPTABLE.
D. PROVIDE FIRE RATED SEALS ON PENETRATIONS IN FIRE RATED FLOORS
AND WALLS. COORDINATE RATED LOCATIONS WITH LIFE SAFETY CODE
PLAN DRAWINGS.
E. PROVIDE INSULATED BUSHINGS FOR ROUGH-IN AND CONDUIT SLEEVE
LOCATIONS PRIOR TO INSTALLATION OF ANY CABLING.
F. BRANCH CIRCUITS CONDUCTOR LENGTHS FROM PANEL LONGER THAN 100’
FOR 120V AND 200' FOR 277V SHALL BE #10 OR LARGER FOR ENTIRE
LENGTH OF CIRCUIT FOR LINE, NEUTRAL, AND GROUND WIRES.
G. PROVIDE DEDICATED NEUTRAL FOR EACH MULTIWIRE BRANCH CIRCUIT
PHASE CONDUCTOR. PROVIDE DEDICATED NEUTRAL FOR EACH DIMMING
CIRCUIT.
H. DEVICES IN FINISHED AREAS ARE TO BE RECESSED WITHIN WALLS EXCEPT
WHERE REQUIRED TO BE SURFACE MOUNTED. IN UNFINISHED AREAS
(PLUMBING CHASES, JANITORS CLOSETS, ELECTRICAL ROOMS, AND
MECHANICAL ROOMS) DEVICES AND CONDUIT MAY BE SURFACE MOUNTED.
I. LIGHT SWITCHES SHALL BE MOUNTED ON LATCH SIDE OF DOOR, WITHIN 12"
OF DOOR/SIDELIGHT FRAMING, UNLESS NOTED OTHERWISE. LIGHT
SWITCHES INSTALLED ADJACENT TO DOOR SWINGS SHALL BE MOUNTED
CLEAR OF DOOR SWING AND WITHIN 12" OF DOOR IN OPEN POSITION.
COORDINATE LOCATION WITH OTHER WALL DEVICES.
J. COORDINATE LUMINAIRE LOCATIONS WITH STRUCTURAL AND MECHANICAL
TRADES PRIOR TO INSTALLATION. COORDINATE MOUNTING HEIGHTS AND
LOCATIONS OF LUMINAIRES IN MECHANICAL ROOMS WITH DUCTS, PIPES,
AND EQUIPMENT. MOUNT LUMINAIRES BELOW DUCTS AND PIPES AND AVOID
MOUNTING LUMINAIRES OVER EQUIPMENT. SUPPORT LUMINAIRES
INDEPENDENTLY OF DUCTS, PIPES, AND EQUIPMENT.
K. VERIFY OCCUPANCY SENSOR DEVICE LAYOUT AND QUANTITIES FOR
COMPLETE AREA/ROOM COVERAGE WITH SENSOR MANUFACTURER PRIOR
TO ROUGH-IN.
L. COORDINATE CEILING TYPES, RECESS CONDITIONS, AND MOUNTING
HARDWARE REQUIRED PRIOR TO PURCHASE OF LUMINAIRES.
M. WIRING SHALL NOT FEED THROUGH FIXTURES EXCEPT TO SERVE
CONTINUOUS ROWS OF SIMILAR TYPE OF LUMINAIRES.
N. FOR EXISTING PANELS, CIRCUIT NUMBERS ARE FOR REFERENCE ONLY.
COORDINATE EXISTING PANEL CONFIGURATION. UTILIZE EXISTING DEMOED
CIRCUITS FEEDING THIS AREA. PROVIDE NEW, UPDATED, TYPED PANEL
INDEX FOR MODIFIED PANELS. UNUSED CIRCUIT BREAKERS SHALL BE
LISTED AS SPARE.
O. COORDINATE DEMOLITION AND NEW WORK AS TO NOT REMOVE SYSTEMS,
DEVICES, AND/OR ACCESSORIES NECESSARY FOR AREAS IN LATER
PHASES.
P. PROVIDE NON-METALLIC SURFACE RACEWAY FOR DEVICES MOUNTED ON
EXISTING SOLID WALLS. EXPOSED/SURFACE CONDUIT IS NOT ALLOWED.
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMP
321 4 5 6 7 8 9 10
GENERAL NOTES
KEY PLAN
KEYNOTES
AREA A
B400 KEY PLAN
AREA B
AREA
A1
AREA C
ARCHITECT/ENGINEER OF RECORD
A/E:
CONSULTANT
C&S Engineers, Inc.
2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com
Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com
Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com
B
IM
/6
-3
B
E x p a n d
R e lo c a te
U rg e n t
C a re A n d
R e n o v a te s t F lo o r P a ti e n t C a re
/6
-3
.4
.M
E P
.r v t
/1
/2
:4
:1
A
M
EL102
B400 - LEVEL 2 - LIGHTING PLAN
Expand and Renovate B400 for
Urgent and Primary Care
500 E Veterans St, Tomah, WI 54660
676-19-327
400/407
05/20/2021 A.BARTSCH T.INGLE
TRIPLE C - THE A&E GROUP
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
ISSUED FOR
CONSTRUCTION
SCALE: 1/8" = 1'-0"
B400 LEVEL 2 FLOOR PLAN - LIGHTING
1 PROVIDE 3-WAY DIMMER SWITCH FOR LOCAL
OVERRIDE OF LIGHTING CONTROL ZONE.
2 PROVIDE ROOM CONTROLLER EQUAL TO STEINEL DCS
CONTROLLER. ROOM CONTROLLER SHALL BE
PROGRAMMED WITH OWNER'S BAS DUSK-TO-DAWN
TIME SETTINGS. LOCAL PIR OCCUPANCY SENSORS
AND DIMMER WALL STATIONS SHALL BE WIRED
THROUGH ROOM CONTROLLER.
Revisions: Date:
ARCHITECT/ENGINEER OF RECORD
A/E:
CONSULTANT
C&S Engineers, Inc.
2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com
Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com
Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com
TRIPLE C - THE A&E GROUP
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
48553 5/20/2021 Anthony R. Nelson
DD
S
D
D
D
D
D
B2 B2
B1 B1
B2 B2
B2 B2
B2B2B2B2
B2 B2 B2 B2
B2 B2 B2 B2
A5 H1 H1
OFFICE
3790A
MECH / ELECT
3790C
OFFICE
3775B
OPEN OFFICE
OFFICE
3790B
BEDROOM
BEDROOM
MECHANICAL ROOM
3780A
MECH / ELEC
MECHANICAL ROOM
BEDROOM
MEDS
3711A
BEDROOM
STORAGE
DINING
3749A
BREAK
3765 BEDROOM
WARD
READING
BEDROOM
TREATMENT
CT CLINIC
TOILET
3744A
CLOSET
RESTROOM
RESTROOM
SHOWERS
3784A
DRESSING
DRESSING
SHOWERS
3715A
Room
DAY ROOM
TOILET
CLOSET
3750A
CORRIDOR
7C36
CORRIDOR
7C31
DATA CLOSET
3772A
ELECTRICAL
CORRIDOR
7C38
CORRIDOR
7C39
OFFICE
STAIR
S4
CORRIDOR
7C37
CORRIDOR
7C32
HAC
3736A
NURSES
BEDROOM
BEDROOM
READING
UTILITY
WARD
STAIR
S6
DINING
LOCKERS
WARD
BEDROOM
BEDROOM
CLEAN LINENS
Room
CLOSET
ELEVATOR LOBBY
7C35
ELEVATOR
CORRIDOR
CORRIDOR
7C33
BEDROOM
LAUNDRY
OPEN OFFICE
B1 B1 B2
H1 H1
B2 B2 B2 B2
B2B2B2B2
B2
B2 B2
B2 B2
B2 B2
B2
407.A
407.B1
407.C1
407.D1
407.E
407.F
407.G1
407.H
407.I
407.J
407.K
407.L
407.M
407.N
407.14407.11 407.12.1407.12
407.9407.7
407.41407.4407.3407.21
J.39
J.40
J.41
407.H2
407.H1
407.13.1
E1
B1 B1
E1
CP3-3-1 CP3-3-1 CP3-3-1 CP3-3-1
CP3-3-1CP3-3-1LS1-3-17CP3-3-1
CP3-3-1 CP3-3-1 CP3-3-1 CP3-3-1
CP3-3-1CP3-3-1CP3-3-1CP3-3-1
CP3-3-1 CP3-3-1
LS1-3-17 CP3-3-1 CP3-3-1
CP3-3-2CP3-3-2
CP3-3-2 CP3-3-2
CP3-3-2CP3-3-2
CP3-3-2
CP3-3-2
CP3-3-2 CP3-3-2 CP3-3-2 CP3-3-2
CP3-3-2CP3-3-2CP3-3-2CP3-3-2
CP3-3-2 CP3-3-2 CP3-3-2 CP3-3-2
CP3-3-2 CP3-3-2
CP3-3-2CP3-3-2
LS1-3-17
LS1-3-17
LS1-3-17
EX CP3-3
EX CP1-3
EX LS1-3
EX NP1-3
EX BLANK
EX BLANK EX BLANK
LC-11
LC-7
LC-11
LC-3
LC-7
LC-11 LC-3
EX LS-2-3
EX NP2-3
EX CP4-3
NL
NL
DEDUCT ALT 1:
REMOVE WORK
ASSOCIATED WITH
B407 NORTH.
DEDUCT ALT 2:
REMOVE WORK
ASSOCIATED WITH
B407 SOUTH.
DEDUCT ALT 2:
REMOVE WORK
ASSOCIATED WITH
B407 SOUTH.
A. ALIGN DEVICES VERTICALLY WHERE LIGHTING, POWER, AND SYSTEM
DEVICES WITH DIFFERENT MOUNTING HEIGHTS ARE INDICATED CLOSE TO
OTHER DEVICES.
B. REFER TO THE ARCHITECTURAL ELEVATION, DETAIL, AND REFLECTED
CEILING PLAN DRAWINGS FOR COORDINATION OF ELECTRICAL DEVICES.
C. CUTTING, DRILLING, AND/OR BORING THROUGH STRUCTURAL MEMBERS IS
NOT ACCEPTABLE.
D. PROVIDE FIRE RATED SEALS ON PENETRATIONS IN FIRE RATED FLOORS
AND WALLS. COORDINATE RATED LOCATIONS WITH LIFE SAFETY CODE
PLAN DRAWINGS.
E. PROVIDE INSULATED BUSHINGS FOR ROUGH-IN AND CONDUIT SLEEVE
LOCATIONS PRIOR TO INSTALLATION OF ANY CABLING.
F. BRANCH CIRCUITS CONDUCTOR LENGTHS FROM PANEL LONGER THAN 100’
FOR 120V AND 200' FOR 277V SHALL BE #10 OR LARGER FOR ENTIRE
LENGTH OF CIRCUIT FOR LINE, NEUTRAL, AND GROUND WIRES.
G. PROVIDE DEDICATED NEUTRAL FOR EACH MULTIWIRE BRANCH CIRCUIT
PHASE CONDUCTOR. PROVIDE DEDICATED NEUTRAL FOR EACH DIMMING
CIRCUIT.
H. DEVICES IN FINISHED AREAS ARE TO BE RECESSED WITHIN WALLS EXCEPT
WHERE REQUIRED TO BE SURFACE MOUNTED. IN UNFINISHED AREAS
(PLUMBING CHASES, JANITORS CLOSETS, ELECTRICAL ROOMS, AND
MECHANICAL ROOMS) DEVICES AND CONDUIT MAY BE SURFACE MOUNTED.
I. LIGHT SWITCHES SHALL BE MOUNTED ON LATCH SIDE OF DOOR, WITHIN 12"
OF DOOR/SIDELIGHT FRAMING, UNLESS NOTED OTHERWISE. LIGHT
SWITCHES INSTALLED ADJACENT…