ATTACHMENT 5 - Mechanical.pdf

PDF 17 MB Posted

Attached to
Y1DZ--Expand and Renovate B400 for Urgent and Primary Care (Minor) - Tomah
Solicitation number
36C77621B0009
Issued by

About this file

This document provides details for a federal contract solicitation to expand and renovate a building for urgent and primary care services. The solicitation number is 36C77621B0009 issued by the Department of Veterans Affairs Technology Acquisition Center Austin. Contractors are sought to completely prepare the site for building operations, including demolition and removal of existing structures, and furnish all labor, materials, and work to expand and renovate building B400 for urgent and primary care as specified in the attached drawings and specifications. The location of the project is at the Tomah VA facility. Responses are due based on the standard solicitation timeline and procedures issued by the contracting agency.

View the file

Other files

File Type Posted
31 23 19 DEWATERING.pdf PDF
36C77621B0009 0003.pdf PDF
Drawings VF100 - VF101.pdf PDF
Technical Questions - FINAL - Tomah 8-2-21.pdf PDF
36C77621B0009 0002.pdf PDF
ATTACHMENT 17 - Construction Wage Rates - Monroe County - 7-9-21.pdf PDF
Site Visit Sign-in Sheet - Tomah - 9 AM - 7-12-21.pdf PDF
36C77621B0009 0001.pdf PDF
Site Visit Sign-in Sheet - Tomah - 10 AM - 7-13-21.pdf PDF
ATTACHMENT 20 - Site Visit Registration - Map.pdf PDF
36C77621B0009 - 6-29-21.pdf PDF
ATTACHMENT 15 - Fire Alarm.pdf PDF
ATTACHMENT 7 - Fire Protection.pdf PDF
ATTACHMENT 16 - Contractor Core Work Hours.pdf PDF
ATTACHMENT 17 - Construction Wage Rates - Monroe County - 5-14-21.pdf PDF
ATTACHMENT 12 - Furniture.pdf PDF
ATTACHMENT 4 - Electrical.pdf PDF
ATTACHMENT 13 - Civil.pdf PDF
ATTACHMENT 11 - Architectual.pdf PDF
ATTACHMENT 8 - Equipment.pdf PDF
ATTACHMENT 1 - Specifications Final 6-21-21.pdf PDF
ATTACHMENT 6 - Plumbing.pdf PDF
ATTACHMENT 2 - General.pdf PDF
ATTACHMENT 19 - Contractor Safety - Environmental Form.docx DOCX document
ATTACHMENT 10 - Signage.pdf PDF
ATTACHMENT 18 - Limitations on Subcontracting - Construction.docx DOCX document
ATTACHMENT 9 - Interiors.pdf PDF
ATTACHMENT 3 - Structural.pdf PDF
ATTACHMENT 14 - Hazard.pdf PDF
Show all 29

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A L

M

B

C N

OD

E

P

Q

R

S

F

G

T

H

U

V

W

I

K

AD ACCESS DOOR

ACFM ABSOLUTE CUBIC FEET PER MINUTE

AFF ABOVE FINISHED FLOOR

AFM AIR FLOW MEASURING DEVICE

AFMS AIR FLOW MOISTURIZING STATION

AHU AIR HANDLING UNIT

AMB AMBIENT

AP ACCESS PANEL

APPROX APPROXIMATE

ASR AUTOMATIC SPRINKLER RISER

LAT LEAVING AIR TEMPERATURE

LBS/HR POUNDS PER HOUR

LGT LENGTH

LP LOW POINT

LRA LOCKED ROTOR AMPERS

LVG LEAVING

LWT LEAVING WATER TEMPERATURE

BFP BACKFLOW PREVENTER

BHP BRAKE HORSEPOWER

BOD BOTTOM OF DUCT

BOP BOTTOM OF PIPE

BTU(H) BRITISH THERMAL UNIT (PER HOUR)

MAX MAXIMUM

MBH 1000 BTU/HR

MCC MOTOR CONTROL CENTER

MECH MECHANICAL

MER MECHANICAL EQUIPMENT ROOM

MIN MINIMUM

MISC MISCELLANEOUS

MTG MOUNTING

NC NOISE CRITERIA

N.C. NORMALLY CLOSED

NIC NOT IN CONTRACT

NO. NUMBER

N.O. NORMALLY OPEN

NOM NOMINAL

NPSH NET POSITIVE SUCTION HEAD

(NRL) NEW LOCATION OF RELOCATED

MATERIAL OR EQUIPMENT

NTS NOT TO SCALE

CAP. CAPACITY

CDSR CONDENSER

CFH CUBIC FEET PER HOUR

CFM CUBIC FEET PER MINUTE

CI CAST IRON

CO CLEAN OUT

COMP COMPRESSOR

COND CONDENSATE

CONT CONTINUATION

CW COLD WATER

DB DECIBELS

DBA DECIBELS (A-WEIGHTED SCALE)

DBT DRY BULB TEMPERATURE °F

DDC DIRECT DIGITAL DRIVE

DIA DIAMETER

DN DOWN

DP DIFFERENTIAL PRESSURE

DPT DEW POINT TEMPERATURE °F

DWG DRAWING

DX DIRECT EXPANSION

D&T DRIP & TRAP

OA OUTSIDE AIR

OAD OUTSIDE AIR DAMPER

OD OUTSIDE DIAMETER

OFD OVERFLOW DRAIN

OPR OPERATING

OV OUTLET VELOCITY

PD PRESSURE DROP (FEET OF WATER)

PRESS PRESSURE

PRV PRESSURE REGULATING VALVE

PSI POUNDS PER SQUARE INCH

PSIG POUNDS PER SQUARE INCH - GUAGE

QTY QUANTITY

RA RETURN/RELIEF AIR

RC ROOF CONDUCTOR

RD ROOF DRAIN

RH RELATIVE HUMIDITY

(RL) RELOCATED MATERIAL OR EQUIPMENT

RLA RUNNING LOAD AMPS

RPM REVOLUTIONS PER MINUTE

RET RETURN

RE REFERENCE

SA SUPPLY AIR

SA SHOCK ABSORBER

SA SOUND ATTENUATOR

SAN SANITARY WASTE

SCFM STANDARD CUBIC FEET PER MINUTE

SD SMOKE DETECTOR

SDP SMOKE DAMPER

SENS SENSIBLE

SF SQUARE FEET

SG SPECIFIC GRAVITY

SL SOUND LINING

SP STATIC PRESSURE (INCHES OF WATER)

SPD SPEED

SPL SOUND POWER LEVEL

SPS STATIC PRESSURE SENSOR

SS STAINLESS STEEL

STM STEAM

TAB TESTING, ADJUSTING AND BALANCING

TEMP TEMPERATURE

TP TOTAL PRESSURE; TRAP PRIMER

TYP TYPICAL

UON UNLESS OTHERWISE NOTED

V VOLTS

VAC VACUUM

VEL VELOCITY

VFD VARIABLE FREQUENCY DRIVE

VTR VENT THRU ROOF

W WATTS

W/ WITH

W/O WITHOUT

WBT WET BULB TEMPERATURE

WDT WIDTH

WG WATER GUAGE

WH WALL HYDRANT

EA EACH; EXHAUST AIR

EAT ENTERING AIR TEMPERATURE

EER ENERGY EFFICIENCY RATIO

EFF EFFICIENCY

EGW ETHYLENE GLYCOL WATER SOLUTION

(% GLYCOL BY VOLUME)

EL ELEVATION

ENT ENTERING

EQ EQUIVALENT

ESP EXTERNAL STATIC PRESSURE

EWC ELECTRIC WATER COOLER

EWT ENTERING WATER TEMPERATURE

EXH EXHAUST

EXP EXPANSION

EXT EXTERNAL

(E) EXISTING

F FAHRENHEIT

FD FLOOR DRAIN

FDP FIRE DAMPER

FH FUME HOOD

FLA FULL LOAD AMPERS

FLEX FLEXIBLE CONNECTION

FLR FLOOR

FM FLOW METER

FPM FEET PER MINUTE

FS FLOW SWITCH

FSDP FIRE & SMOKE DAMPER

FT FEET or FOOT

GAL GALLONS

GPM GALLONS PER MINUTE

GR GRAINS

HB HOSE BIBB

HG MERCURY

HGT HEIGHT

HO HUB OUTLET

HP HORSE POWER

HR HOUR

HUM HUMIDIFIER

HZ HERTZ

ID INSIDE DIAMETER

IE INVERT ELEVATION

IFB INTEGRAL FACE AND BY-PASS

IN. INCHES

KW KILOWATTS

SEE MECHANICAL SYMBOLS, LEGENDS AND EQUIPMENT SCHEDULES

FOR ADDITIONAL ABBREVIATIONS. ALL ABBREVIATIONS, SYMBOLS,

AND LEGENDS SHOWN ON THIS DRAWINGS ARE NOT NECESSARILY

USED.

R

UNIT HEATER

OF AIR FLOW 45° OFFSETS

RETURN OR EXHAUST AIR FLOW

SUPPLY OR OUTSIDE AIR FLOW

SIDE WALL SUPPLY DIFFUSER

SIDE WALL RETURN or EXHAUST

GRILLE/REGISTER

PRESSURE REGULATING VALVE, FLANGED

HORIZONTAL FIRE DAMPER

REDUCER - ECCENTRIC

UP or DN

TEE OUTLET - UP

REDUCED PRESSURE BACKFLOW PREVENTER

AIR VENT

DROP OR RISE

DIRECTION OF FLOW

DIRECTION OF PIPE PITCH

CONNECT OUT OF TOP

FLOW METER

ELBOW - TURNED UP OR RISER CONNECTION

PRESSURE GUAGE WITH COCK

QUICK COUPLING

ELBOW - TURNED DOWN

TEE OUTLET - DOWN

CAP OR PLUG

THERMOMETER

ALIGNMENT GUIDE

PIPE UNION

PIPE ANCHOR

FLOOR DRAIN (ROUND)

ROOF DRAIN (RD)

RUNNING TRAP

CLEANOUT IN FLOOR

REDUCER - CONCENTRIC

HOSE CONNECTION

WALL HYDRANT

STEAM TRAP

CLEANOUT

HOSE BIBB

FLOW INDICATING BALANCE VALVE

ORIFICE PLATE

FLEXIBLE CONNECTION

STRAINER

PRESSURE REDUCING VALVE

SAFETY RELIEF VALVE

VERTICAL DUCT DROP

VERTICAL DUCT RISE

DIRECTION OF FLOW

SMOKE DAMPER

VERTICAL FIRE DAMPER

BUTTERFLY VALVE (ISOLATION OR THROTTLING)

SELF ACTUATING TYPE DIFFERENTIAL PRESSURE

AUTOMATIC FLOW CONTROL VALVE

3-WAY ELECTRIC CONTROL VALVE

BALL VALVE (ISOLATION OR THROTTLING)

PLUG VALVE (ISOLATION OR THROTTLING)

AUTOMATIC DPCV

CONTROL VALVE (DPCV)

SOLENOID VALVE

2-WAY ELECTRIC CONTROL VALVE

3-WAY PNEUMATIC CONTROL VALVE

2-WAY PNEUMATIC CONTROL VALVE

ANGLE VALVE

CHECK VALVE

ISOLATION VALVE

THROTTLING VALVE

AUTOMATIC DAMPER (MOTORIZED)

VOLUME DAMPER (MANUAL)

ROOM THERMOSTAT

SMOKE DETECTOR

FLOW SWITCH

STATIC PRESSURE SENSOR

AIR SYSTEMS

SUPPLY

RETURN

T

PRESSURE REGULATING VALVE, THREADED

FLOOR DRAIN (RECTANGULAR)

SA

RA

TE

GE

SUPPLY AIR

RETURN AIR

GENERAL EXHAUST

TOILET EXHAUST

(NOTES APPLY TO ALL MECHANICAL DRAWINGS.)

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

VAV BOX

VAV BOX

OUTSIDE AIR INTAKE

DUCT SYSTEM LOCATION

PRESSURE

CLASSIFICATION

(INCH WATER

GAUGE)

REMARKS

FROM TO

FAN DISCHARGE

FAN INLETGRILLE

GENERAL EXHAUST

RETURN

SUPPLY

2"

2"

2"

4"

THROUGH OUT 2"

DIFFUSER

OWS OPERATOR WORK STATION

EXHAUST

HHWS HEATING HOT WATER SUPPLY

HHWR HEATING HOT WATER RETURN

CWS CONDENSER WATER SUPPLY

CWR CONDENSER WATER RETURN

HPR (PSIG)

LPR (PSIG)

PS

D

HPS (PSIG)

LPS (PSIG)

CS (PSIG)

PHWS

PHWR

RL

RS

CHWS

CHWR

RHG

CONDENSATE DRAIN

HIGH PRESSURE CONDENSATE RETURN

LOW PRESSURE CONDENSATE RETURN

LOW PRESSURE STEAM

CLEAN STEAM

PUMPED CONDENSATE

HIGH PRESSURE STEAM

PERIMETER HEATING WATER RETURN

PERIMETER HEATING WATER SUPPLY

CHILLED WATER SUPPLY

CHILLED WATER RETURN

REFRIGERANT HOT GAS

REFRIGERANT SUCTION

REFRIGERANT LIQUID

SD

FS

SP

SMOKE/FIRE COMBINATION DAMPER

INSTALL ALL WORK IN ACCORDANCE WITH THE WISCONSIN CODE, WISCONSIN PLUMBING CODE, WISCONSIN ENERGY CODE, WISCONSIN ELECTRIC CODE AND

THE REGULATIONS OF ALL AUTHORITIES HAVING JURISDICTION.

TO OBTAIN ALL CONSTRUCTION INFORMATION, ALL SPECIFICATION AND DRAWINGS (E.G. ARCHITECTURAL, STRUCTURAL, CIVIL, MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION MUST BE USED.

BRING TO THE ATTENTION OF THE ARCHITECT/ENGINEER ANY INFORMATIONAL CONFLICTS WITHIN THE SPECIFICATIONS AND DRAWINGS. THE CONTRACTOR(S) SHALL NOT PROCEED WITH ANY WORK, EXCEPT AT ITS OWN RISK, UNTIL ALL CONFLICTS ARE RESOLVED AND THE CLARIFYING INFORMATION IS ISSUED TO THE

CONTRACTOR(S) BY THE ARCHITECT/ENGINEER.

COORDINATE DIFFUSER & REGISTER LOCATIONS WITH ARCHITECTURAL REFLECTED CEILING PLANS.

COORDINATE ALL WALL MOUNTED DEVICES SUCH AS THERMOSTATS AND CONTROL PANELS WITH ARCHITECTURAL INTERIOR ELEVATIONS.

ALL DIMENSIONS SHOWN FOR DUCTWORK ARE NET INSIDE DIMENSIONS.

FURNISH AND INSTALL ALL MANUALLY OPERATED VOLUME CONTROL (BALANCING) DAMPERS NECESSARY TO PERFORM THE BALANCING WORK.

THOUGH SOME OFFSETS & TRANSITIONS ARE SHOWN IN PIPING & SHEET METAL TO HELP INDICATE THE PHYSICAL RELATIONSHIP BETWEEN THEM, IT IS NOT THE INTENT OF THE DRAWINGS TO SHOW ALL PIPING & SHEET METAL OFFSETS & TRANSITIONS REQUIRED. THE CONTRACTOR SHALL FULLY COORDINATE THE MECHANICAL WORK WITHIN ITSELF & WITH THE WORK OF ALL TRADES TO PROVIDE COMPLETE & OPERABLE SYSTEMS WITHOUT INTERFERENCES.

DUCT CONSTRUCTION SHALL FOLLOW THE LATEST SMACNA STANDARDS FOR THE SPECIFIC PRESSURE CLASSIFICATIONS INDICATED BELOW.

BUILDING IS TO BE FULLY SPRINKLED; SPRINKLER LAYOUT SHALL CONFORM TO NFPA 13. REFLECTED CEILING PLANS SHOW SPRINKLER LAYOUT FOR SOME AREAS. REFER TO SPECIFICATIONS & ARCHITECTURAL DRAWINGS FOR ADDITIONAL LAYOUT REQUIREMENTS.

PROVIDE DUCT PRESSURE CLASSIFICATIONS AS FOLLOWS:

EXISTING TRADES SHOWN IN LIGHT LINES.

NEW CONSTRUCTION SHOWN IN DARK LINES.

VAV BOXAIR INLET

FAN INLETVAV BOX

3"

BCW BOOSTED COLD WATER

SUB-METER FOR COLD WATER, HOT WATER, GAS

HORIZONTAL SMOKE/FIRE COMBINATION DAMPER

TEST PORT

HB

ST

HC

S

M

M

M

AIR VENT WITH VALVE

RD

FD

FD

CO

CO

RISER DESIGNATION (TYPE AS INDICATED)

SECTION NUMBER

DETAIL NUMBER

DRAWING NUMBER WHERE DRAWN

DRAWING NUMBER WHERE DRAWN

E1-1.0

E1-1.0

KEY NOTE

DUCTWORK

SEAL/LEAKAGE

CLASS

A

A

A

A

A

A

NEW DUCTWORK

DEMO DUCTWORK

EXISTING DUCTWORK

1. (E) MECHANICAL SHOWN ON DRAWINGS IS BASED ON AVAILABLE DRAWINGS. INSTALLING CONTRACTOR IS

RESPONSIBLE FOR FIELD VERIFICATION OF (E) CONDITIONS

2. REMOVED PIPING TO BE CAPPED & VALVED AT MAIN - NO DEADLEGS TO REMAIN

3. REMOVED DUCTWORK TO BE CAPPED AND SEALED AIR TIGHT AT MAIN.

4. COORDINATE SYSTEM SHUT-DOWNS WITH FACILITIES

5. COORDINATE HOT/FREEZE TAPS WITH FACILITIES

6. ANY ITEMS DESIGNATED BY FACILITIES TO BE RETAINED SHALL BE REMOVED AND TURNED OVER DAMAGE FREE

7. PIPING SHALL BE LABELED PER VA STANDARDS

8. AS-BUILT MARK-UPS WITH VALVE LOCATIONS & LIST SHALL BE TURNED OVER TO FACILITIES

9. ALL PENETRATIONS SHALL BE PROPERLY SEALED AND FIRE STOPPED

GENERAL DEMOLITION NOTES:

FTR FINNED TUBE RADIATOR

SYMBOLS:ABBREVIATIONS:

LINE TYPES: GENERAL NOTES:

PARTITION RATING GRAPHICS:

4 HR FIRE BARRIER

3 HR FIRE BARRIER

2 HR FIRE & SMOKE BARRIER

2 HR FIRE BARRIER

2 HR FIRE BARRIER/SHAFT

1 HR FIRE & SMOKE BARRIER

1 HR FIRE BARRIER

1 HR FIRE BARRIER/SHAFT

SMOKE PARTITION (NON RATED)

NON RATED

PARTITION RATING GRAPHIC DESIGNATION: PRIORITY

1 HIGHEST

5 LOWEST

PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE

RESISTANT, OR BOTH FIRE AND SMOKE RESISTANT ARE SHOWN

GRAPHICALLY ON PLANS WITH HATCH PATTERNS.

DEMO PIPING

RL REFRIGERANT LIQUID

RS REFRIGERANT SUCTION

DEDUCTIVE ALTERNATE:

POINT OF DISCONNECT

POINT OF CONNECTION

1. Deduct Alternate #1: Remove B407 North Swing Space.

a. Remove 60 days from schedule.

2. Deduct Alternate #2: Remove B407 South Swing Space, Bathroom refresh and IT closet infrastructure from project.

a. Remove 90 days from schedule.

3. Deduct Alternate #3: Remove sealed bubble wall fountain in Waiting Room 1082 from project.

a. Remove 14 days from schedule.

4. Deduct Alternate #4: Rebuild (E) AHU rather than install new one.

a. Remove 90 calendar days from schedule.

5. Deduct Alternate #5: Remove exterior entrance canopy at staff lounge 1102.

a. Remove 14 calendar days from schedule.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMP

321 4 5 6 7 8 9 10

ARCHITECT/ENGINEER OF RECORD

A/E:

CONSULTANT

C&S Engineers, Inc.

2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com

Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com

Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com

B

IM

/6

-3

B

E x p a n d

R e lo c a te

U rg e n t

C a re A n d

R e n o v a te s t F lo o r P a ti e n t C a re

/6

-3

.4

.M

E P

.r v t

/2

/2

:0

:2

A

M

M-000

MECHANICAL ABBREVIATIONS AND

SYMBOLS

Expand and Renovate B400 for

Urgent and Primary Care

500 E Veterans St, Tomah, WI 54660

676-19-327

400/407

05/20/2021 K.LEITCH P.KOTTA

TRIPLE C - THE A&E GROUP

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

ISSUED FOR

CONSTRUCTION

MECHANICAL SHEET INDEX

M-000 MECHANICAL ABBREVIATIONS AND SYMBOLS

MD101 B400 - LEVEL 1 - HVAC DEMOLITION PLAN

MD101A B400 - LEVEL 1 - HVAC DEMOLITION PLAN - DEDUCT ALT. #4

MD102 B400 - LEVEL 2 - HVAC DEMOLITION PLAN

MD103-407 B407 - LEVEL 3 - HVAC DEMOLITION PLAN

MD200 B400 - FOUNDATION - HVAC PIPING DEMOLITION PLAN

MD201 B400 - LEVEL 1 - HVAC PIPING DEMOLITION PLAN

MD202 B400 - LEVEL 2 - HVAC PIPING DEMOLITION PLAN

M-100 B400 - LEVEL 1 - HVAC TEMPORARY PLAN

M-101 B400 - LEVEL 1 - HVAC PLAN

M-101A B400 - LEVEL 1 - HVAC PLAN - DEDUCT ALT. #4

M-102 B400 - LEVEL 2 - HVAC PLAN

M-103-407 B407 - LEVEL 3 - HVAC PLAN

MP200 B400 - FOUNDATION - HVAC PIPING PLAN

MP201 B400 - LEVEL 1 - HVAC PIPING PLAN

MP202 B400 - LEVEL 2 - HVAC PIPING PLAN

MP203-407 B407 - LEVEL 3 - HVAC PIPING PLAN

M-400 ENLARGED MECHANICAL PLANS

M-401 ENLARGED MECHANICAL PLANS

M-402 ENLARGED MECHANICAL PLANS - DEDUCT ALT. #4

M-500 MECHANICAL DETAILS

M-501 MECHANICAL DETAILS

M-502 MECHANICAL DETAILS

M-600 MECHANICAL SECTIONS

M-700 MECHANICAL SCHEDULES

M-800 MECHANICAL CONTROLS

M-801 MECHANICAL CONTROLS

M-802 MECHANICAL CONTROLS

Pending Totals: NEW Plumbing systems in crawl space and 1st floor are original. Provide complete new plumbing piping systems, basement, crawl space, 1st floor. Replace all cold water, hot water, drain, waste, and vent piping throughout.

Fixtures / Piping 111175 [ Field Engineer Review Completed on 07/29/2014 by VHATOMBueniM.] [ Auto Generated Project Pending on 07/29/2014 for Project Number 676-14- 122 created by VHATOMBueniM.] Project 676-14-122 replaced the sanitary and storm sewer piping under the west wing.

Replace piping in the basement and in the 1st and 2nd floors, which exceed maximum life expectancy.

Fire Sprinkler / Pump 90803 Sprinkler piping is in good condition.

Pending Totals: NEW Ambulance Bay exhaust fan Square inline May have a control issue. Fan was running continuously when no source of CO contamination was present. (2010 vintage

Ventil (O.A. & Exh) 111174 Ventilation is in good condition.

Room Air Dist/Term 111173 VAV boxes and reheating coils in good condition.

Heating System 277776 2nd floor steam piping and convectors removed, replaced by hot water heaters or air-side heating.

Heating System 111168 The original steam piping and convectors on the 1st floor has exceeded their life expectancy and should be replaced.

Engr. Control syst. 111167 METASYS controls on the 1st and 2nd floors installed in 2005 and are in good condition.

Ducts & Water Dist 111166 Ducts and piping in good condition.

Pending Totals: NEW Air Handler (2004) serving the current dental in good condition, Air Handler is Mixed Air, Pre-Filter, Air Blender, Hot Water Pumped Heating Coil, CW Cooling Coil, Diffuser, Supply Fan with ABB VFD, Filter, Steam Humidifier on discharge *AHU-8 Trane MN: MCCB025UAODOUA SN:K04M65739A

Mechanical Rec No Description

Building 400 FCA Report

Disclaimer: These items have been determined to have reached their end of life usefulnes. This scope of work contract did not allocate funding for the below mentioned deficiencies. The following information was received from the owner's assessment report dated 1/6/2017.

Revisions: Date:

ARCHITECT/ENGINEER OF RECORD

A/E:

CONSULTANT

C&S Engineers, Inc.

2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com

Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com

Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com

TRIPLE C - THE A&E GROUP

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

43886

05/20/2021 KAEKO LEITCH

1 2 3 4 5 6 6.1 7 7.8 8 9 9.1 9.9 10 11 11.2 12 13 14 18171615

M.3

M

L

K.3

K

J.4

J.3

J

I.5

I.2

I

H.1

H

G

F.1

F

E

D

C

B

A

(E )1

4" x1

2" S

A (E

)1 8" x1 2"

S A

(E )2

8" x1

2" S

A

(E)30"x12" RA

(E)30"x12" RA

(E)24"x4"

(E )2

4" x1

0" R

A (E

)1 8" x8

R A

(E )1

4" x8

R

A (E

)8 "x

8"

(E )3

0" x1

2" S

A

(E)30"x12" SA

(E)12"x6"

(E)12"x6"

(E)16"x14" (E)18"x14"

(E)36"x16"

(E )2

4" x1

2" (E

)2 0" x1 2"

(E)18"x12" (E)14"x12"

(E)10"x10"

(E)10"x10"

(E)16"x12" SA

(E )2

2" x1

2" S

A (E

)2 8" x1 2"

S A

(E)32"x12" SA

(E)32"x12"

(E)20"x12"

(E)18"x30"

(E )2

0" x1

2"

(E)12"x8" SA

(E)14"x12"

(E)18"x10"

(E)14"x8"

(E )1

4" ø

(E )1

0" ø

(E)10"x10"

(E)10"x8"

(E)14"ø SA

(E)10"ø SA

(E)14"x4"

(E)10"x8"

(E)12"x8"

(E)14"x8"(E)12"x8"(E)8"x8"

(E )3

2" x1

2"

(E)8"x10"

(E )1

2" x1

0" (E

)1 2" x1 2"

(E )2

0" x1

2"

(E)10"ø

(E )1

2" x1

0"

(E )1

0" ø

(E )8

"ø

(E)8"ø

(E )1

2" x1

2"

3 3

2 1

1 1

2 1

5 5

(E)3-13

(E)3-15

(E)3-14

(E)3-12

(E)3-10

(E)3-9

(E)3-7

(E)3-6

(E)3-8 (E)3-5

(E)3-4

(E)3-1

(E)1-13

(E)1-11

(E)1-9

(E)1-12

(E)1-10

(E)1-8

(E)1-6

(E)1-2

(E)1-3 (E)1-4

(E)3-11

(E)8"ø

(E)8"ø

(E)8"ø

(E)8"ø

(E)8"x8"

(E)8"ø

(E)8"ø

(E)6"ø

(E )1

0" x1

0" R

A (E

)1 4" x1 0"

R A

(E)20"x10" RA

(E)6"ø

(E)30"x12" SA UP

(E)30"x12" RA UP ø8" ø8"

(E)8"x8"

(E )3

0" x1

2" ø10" ø10" ø8" (E)8"ø ø8"

(E)8"ø

(E)20"x14"

(E )3

6" x1

6" (E

)3 6" x1 0" ø10" ø6"

(E)10"x12" ø6" ø6"

(E)24"x4" ø10" ø10" ø6" ø10" ø10"

(E)10"x8"

(E)16"x96"

(E)3-3

(E)3-2

(E)1-7

(E)1-1 ø8" ø8" ø8" ø8"

(E)22"x8" ø8"

(E)10"ø ø8" ø8" ø8"

(E)12"x12"

(E)10"x8"

(E)12"x12"

(E)12"x12"

(E )1

2" x1

0"

(E )1

2" x1

2"

(E)6"x6"

(E)6"ø ø8"

(E)12"x12"

(E)8"ø

(E)20"x12"

(E)

COOLING

TOWER

(E)1-5

(E)8"ø

(E)12"x8" ø8"

(E)30"x12" RA

(E)24"x10" RA

EXAM

EXAM

EXAM

OFFICE

OFFICE

OFFICE

OFFICE

EXAM

OFFICE

OFFICE

DIRTY UTILTIY

OFFICE

WAITING

NURSE STATION

OFFICE

1011 EXAM

CONFERENCE

EXAM

EXAM

EXAM

OFFICE

OFFICE

WOMEN VISITOR TOILET

TLT

MECH

IT

OFFICE

OFFICE

OFFICE

EXAM

STAIR

WAITING / CIRCULATION

EXAM

EXAM

EXAM

NURSE STATION

EXAM

EXAM

WOMEN TLT

EXAM

EXAM

OFFICE

STORAGE

1096A

STAFF TOILET

STAFF TOILET

AMBULANCE GARAGE

A. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS

PRIOR TO BEGINNING WORK AND NOTIFY THE ARCHITECT/

ENGINEER OF ANY DISCREPANCIES BETWEEN THE "AS-

BUILT" CONDITIONS AND THESE DRAWINGS.

B. COORDINATE ALL DUCTWORK INSTALLATION WITH

GENERAL, PLUMBING, FIRE PROTECTION, AND ELECTRICAL

CONTRACTORS. INSTALL ALL DUCTWORK AS HIGH AS

POSSIBLE. PROVIDE ALL NECESSARY OFFSETS (DROPS

AND RISES) TO KEEP DUCTWORK TIGHT TO THE

STRUCTURE ABOVE. OFFSET DUCTWORK TO AVOID

BEAMS

C. REFER TO AND COORDINATE WITH THE ARCHITECTURAL

PLANS FOR CEILING TYPES, HEIGHTS, SOFFIT AREAS, AND

ELEVATIONS FOR INSTALLATION OF NEW VENTILATION

DUCTWORK, EQUIPMENT, ETC.

D. THIS CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND

RE-INSTALLING OF EXISTING CEILING TILE NOT REMOVED

BY THE GENERAL CONTRACTOR FOR THE INSTALLATION

OF NEW VENTILATION DUCTWORK, EQUIPMENT, ETC.

VERIFY WITH ARCHITECTURAL PLANS FOR CEILING WORK

BY THE GENERAL CONTRACTOR. ANY CEILING TILE OR

GRID DAMAGED DURING CONSTRUCTION SHALL BE

REPLACED WITH NEW BY THIS CONTRACTOR.

E. THIS CONTRACTOR SHALL OPEN ALL EXISTING WALLS

AND/ OR CEILINGS FOR INSTALLATION OF NEW

VENTILATION DUCTWORK, EQUIPMENT, ETC. AS REQUIRED.

PATCH WALLS AND OR CEILINGS TO MATCH EXISTING.

F. MAINTAIN 3'-0" CLEAR SPACE IN FRONT OF ALL

ELECTRICAL, CONTROL, AND ACCESS PANELS FOR

ACCESSIBILITY.

G. ALL DAMPERS, ETC. SHALL BE INSTALLED IN ACCESSIBLE

CEILINGS.

H. FIRE CAULK DUCT PENTERATIONS AT RATED WALLS,

CEILING, AND FLOORS. REFER THE ARCHITECTURE SHEET

GI101, GI102, AND GI104 FOR FIRE RATINGS.

I. CONTRACTOR SHALL MAINTAIN ALL RECOMENDED

EQUIPMENT CLEARANCES.

J. REFER TO ARCHITECTURAL PLAN FOR FIRE RATED WALL /

PARTITION / FLOOR / CEILING / ASSEMBLY LOCATIONS.

N

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMP

321 4 5 6 7 8 9 10

GENERAL NOTES

KEY PLAN

KEYNOTES

AREA A

B400 KEY PLAN

AREA B

AREA

A1

AREA C

ARCHITECT/ENGINEER OF RECORD

A/E:

CONSULTANT

C&S Engineers, Inc.

2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com

Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com

Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com

B

IM

/6

-3

B

E x p a n d

R e lo c a te

U rg e n t

C a re A n d

R e n o v a te s t F lo o r P a ti e n t C a re

/6

-3

.4

.M

E P

.r v t

/2

/2

:0

:0

A

M

MD101

B400 - LEVEL 1 - HVAC DEMOLITION

PLAN

Expand and Renovate B400 for

Urgent and Primary Care

500 E Veterans St, Tomah, WI 54660

676-19-327

400/407

05/20/2021 K.LEITCH P.KOTTA

TRIPLE C - THE A&E GROUP

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

ISSUED FOR

CONSTRUCTION

SCALE: 1/8" = 1'-0"

F1

B400 - LEVEL 1 - HVAC DEMOLITION PLAN

1 REMOVE AND REPLACE EXISTING DIFFUSER

AND FLEX DUCT. ANY FLEX DUCT RUNOUT

SHALL NOT EXCEED 5 FEET.

2 REMOVE AND REPLACE EXISTING GRILLE. SEE

NEW WORK FOR LOCATION.

3 EXISTING VAV BOX TO BE REUSED. REMOVE

EXISTING CONTROLS AND REPLACE WITH NEW

DDC CONTROLS. SEE SPECS FOR DETAILS.

4 REMOVE EXISTING BRANCH MAIN TO POINT

INDICATED ON PLAN. CAP AND SEAL

DUCTWORK.

5 REMOVE DUCTWORK TO POINT INDICATED ON

PLAN AND PREPARE FOR FUTURE

CONNECTION. SEE M-101 FOR FUTURE

CONNECTION.

6 REMOVE DUCTWORK TO POINT INDICATED ON

PLAN. CAP AND SEAL DUCT AIR TIGHT.

7 REMOVE EXISTING EXHAUST FAN, FLEX

CONNECTIONS AND DUCT TRANSITIONS.

PREPARE EXISTING EXHAUST INLET AND

OUTLET FOR FUTURE CONNECTION. SEE

M-101 FOR NEW EXHAUST FAN.

8 CONTRACTOR TO RELOCATE EXISTING OA

LOUVER, DUCTWORK, DAMPER, AND

CONTROLS. SEE M-101 FOR NEW LOCATION.

9 REMOVE AHU AND ASSOCIATED

ACCESSORIES.

10 REMOVE EXISTING WINDOW AND PREPARE

OPENING FOR NEW INTAKE LOUVER. SEE NEW

WORK FOR DETAILS.

11 REMOVE INTAKE LOUVER AND PROVIDE

INSULATED CAP AROUND OPENING.

COORDINATE WORK WITH GENERAL

CONTRACTOR.

12 REMOVE EXISTING RETURN AIR DUCT 1'-0"

BELOW FLOOR PENETRATION. CAP AND SEAL

DUCT AIR TIGHT. INFILL FLOOR OPENING WITH

MATERIALS SIMILAR TO EXISTING.

Revisions: Date:

ARCHITECT/ENGINEER OF RECORD

A/E:

CONSULTANT

C&S Engineers, Inc.

2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com

Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com

Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com

TRIPLE C - THE A&E GROUP

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

1 2 3 4 5 6 6.1 7 7.8 8 9 9.1 9.9 10 11 11.2 12 13 18171615

M

L

K.3

K

J.4

J.3

J

I.5

I.2

I

H.1

H

G

F.1

F

E

D

C

B

A

(E )1

4" x1

2" S

A (E

)1 8" x1 2"

S A

(E )2

8" x1

2" S

A

(E)30"x12" RA

(E)30"x12" RA

(E)24"x4"

(E )2

4" x1

0" R

A (E

)1 8" x8

R A

(E )1

4" x8

R

A (E

)8 "x

8"

(E )3

0" x1

2" S

A

(E)30"x12" SA

(E)12"x6"

(E)12"x6"

(E)16"x14" (E)18"x14"

(E)36"x16"

(E )2

4" x1

2" (E

)2 0" x1 2"

(E)18"x12" (E)14"x12"

(E)10"x10"

(E)10"x10"

(E)16"x12" SA

(E )2

2" x1

2" S

A (E

)2 8" x1 2"

S A

(E)32"x12" SA

(E)32"x12"

(E)20"x12"

(E)18"x30"

(E )2

0" x1

2"

(E)12"x8" SA

(E)14"x12"

(E)18"x10"

(E)14"x8"

(E )1

4" ø

(E )1

0" ø

(E)10"x10"

(E)10"x8"

(E)14"ø SA

(E)10"ø SA

(E)14"x4"

(E)10"x8"

(E)12"x8"

(E)14"x8"(E)12"x8"(E)8"x8"

(E )3

2" x1

2" S

A

(E)8"x10"

(E )1

2" x1

0" (E

)1 2" x1 2"

(E )2

0" x1

2"

(E)10"ø

(E )1

2" x1

0"

(E )1

0" ø

(E )8

"ø

(E)8"ø

(E )1

2" x1

2"

3 3

2 1

1 1

2 1

4 4

(E)3-13

(E)3-15

(E)3-14

(E)3-12

(E)3-10

(E)3-9

(E)3-7

(E)3-6

(E)3-8 (E)3-5

(E)3-4

(E)3-1

(E)1-13

(E)1-11

(E)1-9

(E)1-12

(E)1-10

(E)1-8

(E)1-6

(E)1-2

(E)1-3 (E)1-4

(E)3-11

(E)8"ø

(E)8"ø

(E)8"ø

(E)8"ø

(E)8"x8"

(E)8"ø

(E)8"ø

(E)6"ø

(E )1

0" x1

0" R

A (E

)1 4" x1 0"

R A

(E)20"x10" RA

(E)6"ø

(E)30"x12" SA UP

(E)30"x12" RA UP ø8" ø8"

(E)8"x8"

(E )3

0" x1

2" ø10" ø10" ø8" (E)8"ø ø8"

(E)8"ø

(E)20"x14"

(E )3

6" x1

6" (E

)3 6" x1 0" ø10" ø6"

(E)10"x12" ø6" ø6"

(E)24"x4" ø10" ø10" ø6" ø10" ø10"

(E)10"x8"

(E)16"x96"

(E)3-3

(E)3-2

(E)1-7

(E)1-1 ø8" ø8" ø8" ø8"

(E)22"x8" ø8"

(E)10"ø ø8" ø8" ø8"

(E)12"x12"

(E)10"x8"

(E)12"x12"

(E)12"x12"

(E )1

2" x1

0"

(E )1

2" x1

2"

(E)6"x6"

(E)6"ø ø8"

(E)12"x12"

(E)8"ø

(E)20"x12"

(E)

COOLING

TOWER

(E)1-5

(E)8"ø

(E)12"x8" ø8"

(E)30"x12" RA

(E)24"x10" RA

(E)80"x12" (E)72"x12" (E)58"x12"

(E) 30x20 RA DN

DEDUCT ALT. #4:

REBUILD (E) AHU RATHER

THAN INSTALL NEW ONE

DEDUCT ALT. #4:

REBUILD (E) AHU RATHER

THAN INSTALL NEW ONE

EXAM

EXAM

EXAM

OFFICE

OFFICE

OFFICE

OFFICE

EXAM

OFFICE

OFFICE

DIRTY UTILTIY

OFFICE

WAITING

NURSE STATION

OFFICE

1011 EXAM

CONFERENCE

EXAM

EXAM

EXAM

OFFICE

OFFICE

WOMEN VISITOR TOILET

TLT

MECH

IT

OFFICE

OFFICE

OFFICE

EXAM

STAIR

WAITING / CIRCULATION

EXAM

EXAM

EXAM

NURSE STATION

EXAM

EXAM

WOMEN TLT

EXAM

EXAM

OFFICE

STORAGE

1096A

STAFF TOILET

STAFF TOILET

AMBULANCE GARAGE

A. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS

PRIOR TO BEGINNING WORK AND NOTIFY THE ARCHITECT/

ENGINEER OF ANY DISCREPANCIES BETWEEN THE "AS-

BUILT" CONDITIONS AND THESE DRAWINGS.

B. COORDINATE ALL DUCTWORK INSTALLATION WITH

GENERAL, PLUMBING, FIRE PROTECTION, AND ELECTRICAL

CONTRACTORS. INSTALL ALL DUCTWORK AS HIGH AS

POSSIBLE. PROVIDE ALL NECESSARY OFFSETS (DROPS

AND RISES) TO KEEP DUCTWORK TIGHT TO THE

STRUCTURE ABOVE. OFFSET DUCTWORK TO AVOID

BEAMS

C. REFER TO AND COORDINATE WITH THE ARCHITECTURAL

PLANS FOR CEILING TYPES, HEIGHTS, SOFFIT AREAS, AND

ELEVATIONS FOR INSTALLATION OF NEW VENTILATION

DUCTWORK, EQUIPMENT, ETC.

D. THIS CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND

RE-INSTALLING OF EXISTING CEILING TILE NOT REMOVED

BY THE GENERAL CONTRACTOR FOR THE INSTALLATION

OF NEW VENTILATION DUCTWORK, EQUIPMENT, ETC.

VERIFY WITH ARCHITECTURAL PLANS FOR CEILING WORK

BY THE GENERAL CONTRACTOR. ANY CEILING TILE OR

GRID DAMAGED DURING CONSTRUCTION SHALL BE

REPLACED WITH NEW BY THIS CONTRACTOR.

E. THIS CONTRACTOR SHALL OPEN ALL EXISTING WALLS

AND/ OR CEILINGS FOR INSTALLATION OF NEW

VENTILATION DUCTWORK, EQUIPMENT, ETC. AS REQUIRED.

PATCH WALLS AND OR CEILINGS TO MATCH EXISTING.

F. MAINTAIN 3'-0" CLEAR SPACE IN FRONT OF ALL

ELECTRICAL, CONTROL, AND ACCESS PANELS FOR

ACCESSIBILITY.

G. ALL DAMPERS, ETC. SHALL BE INSTALLED IN ACCESSIBLE

CEILINGS.

H. FIRE CAULK DUCT PENTERATIONS AT RATED WALLS,

CEILING, AND FLOORS. REFER THE ARCHITECTURE SHEET

GI101, GI102, AND GI104 FOR FIRE RATINGS.

I. CONTRACTOR SHALL MAINTAIN ALL RECOMENDED

EQUIPMENT CLEARANCES.

J. REFER TO ARCHITECTURAL PLAN FOR FIRE RATED WALL /

PARTITION / FLOOR / CEILING / ASSEMBLY LOCATIONS.

N

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMP

321 4 5 6 7 8 9 10

GENERAL NOTES

KEY PLAN

KEYNOTES

AREA A

B400 KEY PLAN

AREA B

AREA

A1

AREA C

ARCHITECT/ENGINEER OF RECORD

A/E:

CONSULTANT

C&S Engineers, Inc.

2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com

Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com

Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com

B

IM

/6

-3

B

E x p a n d R e lo c a te U rg e n t

C a re A n d

R e n o v a te s t F lo o r P a ti e n t

C a re /6

-3

.4

.M

E P

D e s ig n O p ti o n M a y

.r v t

/2

/2

:0

:0

A

M

MD101A

B400 - LEVEL 1 - HVAC DEMO PLAN

- DEDUCT ALT. #4

Expand and Renovate B400 for

Urgent and Primary Care

500 E Veterans St, Tomah, WI 54660

676-19-327

400/407

05/20/2021 K.LEITCH P.KOTTA

TRIPLE C - THE A&E GROUP

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

ISSUED FOR

CONSTRUCTION

SCALE: 1/8" = 1'-0"

F1

B400 - LEVEL 1 - HVAC DEMOLITION PLAN

1 REMOVE AND REPLACE EXISTING DIFFUSER

AND FLEX DUCT. ANY FLEX DUCT RUNOUT

SHALL NOT EXCEED 5 FEET.

2 REMOVE AND REPLACE EXISTING GRILLE. SEE

NEW WORK FOR LOCATION.

3 EXISTING VAV BOX TO BE REUSED. REMOVE

EXISTING CONTROLS AND REPLACE WITH NEW

DDC CONTROLS. SEE SPECS FOR DETAILS.

4 REMOVE DUCTWORK TO POINT INDICATED ON

PLAN AND PREPARE FOR FUTURE

CONNECTION. SEE M-101 FOR FUTURE

CONNECTION.

5 REMOVE DUCTWORK TO POINT INDICATED ON

PLAN. CAP AND SEAL DUCT AIR TIGHT.

6 REMOVE EXISTING EXHAUST FAN, FLEX

CONNECTIONS AND DUCT TRANSITIONS.

PREPARE EXISTING EXHAUST INLET AND

OUTLET FOR FUTURE CONNECTION. SEE

M-101 FOR NEW EXHAUST FAN.

7 CONTRACTOR TO RELOCATE EXISTING OA

LOUVER, DUCTWORK, DAMPER, AND

CONTROLS. SEE M-101 FOR NEW LOCATION.

8 REMOVE AHU AND ASSOCIATED

ACCESSORIES.

9 REMOVE EXISTING WINDOW AND PREPARE

OPENING FOR NEW INTAKE LOUVER. SEE NEW

WORK FOR DETAILS.

10 REMOVE INTAKE LOUVER AND PROVIDE

INSULATED CAP AROUND OPENING.

COORDINATE WORK WITH GENERAL

CONTRACTOR.

11 PRIOR TO CONSTRUCTION, CONTRACTOR TO

PROVIDE A PRE-TAB REPORT AND SUBMIT

REPORT TO ENGINEER/OWNER.

Revisions: Date:

CONSULTANT

C&S Engineers, Inc.

2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com

Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com

Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com

M

L

K.3

K

J.4

J.3

J

I.5

I.2

I

H.1

H

G

F.1

F

E

D

C

B

A

(E)8"x10" SA

(E)12"x10" SA

(E)16"x8" RA

(E)14"x6"

(E)10"x10"

(E)14"x6"

(E)6"x12"

(E)24"x10" RA

(E )2

6" x1

2" R

A (E

)3 4" x1 2"

R A

(E)44"x12" RA(E)44"x22" RA

(E)AH-3

(E)44"x12" RA

(E)8"x8" EA

(E)8"x8"

(E)12"x12" SA

(E)6"x12" SA

(E)6"ø

(E)10"x12" SA

(E)6"x12" SA

(E)14"x8" EA

(E)8"x8" SA

(E)30"x12" SA

(E )3

8" x1

2" R

A

(E)30"x12" SA

(E)30"x12" SA

(E)30"x12" SA

1 2

1 2

(E)5

(E)2

(E)3

(E)7

(E)8

(E)3-18 (E)3-19

(E)38"x12" RA

(E)8"x12"

(E)10"x10"

(E)16"x8" RA

(E)10"ø

(E)4

(E)1

(E)10

(E)9

(E)6

(E)3-20

(E)3-41

(E)

COOLING

TOWER

OFFICE

UNOCCUPIED

CLEAN UTILITY

LAB

MECHANICAL

OFFICE

2015A

TOILET, STAFF

2030A

UTILITY ROOM, SOILED

TOILET

LOCKER ROOM

LAB

TREATMENT ROOM

2025 EXAM/ TREATMENT ROOM

EXAM/ TREATMENT ROOM

TREATMENT ROOM

EXAM/TREATMENT ROOM

TREATMENT ROOM

STAIR

S9

A. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS

PRIOR TO BEGINNING WORK AND NOTIFY THE ARCHITECT/

ENGINEER OF ANY DISCREPANCIES BETWEEN THE "AS-

BUILT" CONDITIONS AND THESE DRAWINGS.

B. COORDINATE ALL DUCTWORK INSTALLATION WITH

GENERAL, PLUMBING, FIRE PROTECTION, AND ELECTRICAL

CONTRACTORS. INSTALL ALL DUCTWORK AS HIGH AS

POSSIBLE. PROVIDE ALL NECESSARY OFFSETS (DROPS

AND RISES) TO KEEP DUCTWORK TIGHT TO THE

STRUCTURE ABOVE. OFFSET DUCTWORK TO AVOID

BEAMS

C. REFER TO AND COORDINATE WITH THE ARCHITECTURAL

PLANS FOR CEILING TYPES, HEIGHTS, SOFFIT AREAS, AND

ELEVATIONS FOR INSTALLATION OF NEW VENTILATION

DUCTWORK, EQUIPMENT, ETC.

D. THIS CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND

RE-INSTALLING OF EXISTING CEILING TILE NOT REMOVED

BY THE GENERAL CONTRACTOR FOR THE INSTALLATION

OF NEW VENTILATION DUCTWORK, EQUIPMENT, ETC.

VERIFY WITH ARCHITECTURAL PLANS FOR CEILING WORK

BY THE GENERAL CONTRACTOR. ANY CEILING TILE OR

GRID DAMAGED DURING CONSTRUCTION SHALL BE

REPLACED WITH NEW BY THIS CONTRACTOR.

E. THIS CONTRACTOR SHALL OPEN ALL EXISTING WALLS

AND/ OR CEILINGS FOR INSTALLATION OF NEW

VENTILATION DUCTWORK, EQUIPMENT, ETC. AS REQUIRED.

PATCH WALLS AND OR CEILINGS TO MATCH EXISTING.

F. MAINTAIN 3'-0" CLEAR SPACE IN FRONT OF ALL

ELECTRICAL, CONTROL, AND ACCESS PANELS FOR

ACCESSIBILITY.

G. ALL DAMPERS, ETC. SHALL BE INSTALLED IN ACCESSIBLE

CEILINGS.

H. FIRE CAULK DUCT PENTERATIONS AT RATED WALLS,

CEILING, AND FLOORS. REFER THE ARCHITECTURE SHEET

GI101, GI102, AND GI104 FOR FIRE RATINGS.

I. CONTRACTOR SHALL MAINTAIN ALL RECOMENDED

EQUIPMENT CLEARANCES.

J. REFER TO ARCHITECTURAL PLAN FOR FIRE RATED WALL /

PARTITION / FLOOR / CEILING / ASSEMBLY LOCATIONS.

N

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMP

321 4 5 6 7 8 9 10

GENERAL NOTES

KEY PLAN

KEYNOTES

AREA A

B400 KEY PLAN

AREA B

AREA

A1

AREA C

ARCHITECT/ENGINEER OF RECORD

A/E:

CONSULTANT

C&S Engineers, Inc.

2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com

Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com

Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com

B

IM

/6

-3

B

E x p a n d

R e lo c a te

U rg e n t

C a re A n d

R e n o v a te s t F lo o r P a ti e n t C a re

/6

-3

.4

.M

E P

.r v t

/2

/2

:0

:1

A

M

MD102

B400 - LEVEL 2 - HVAC DEMOLITION

PLAN

Expand and Renovate B400 for

Urgent and Primary Care

500 E Veterans St, Tomah, WI 54660

676-19-327

400/407

05/20/2021 K.LEITCH P.KOTTA

TRIPLE C - THE A&E GROUP

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

ISSUED FOR

CONSTRUCTION

SCALE: 1/8" = 1'-0"

F1

B400 - LEVEL 2 - HVAC DEMOLITION PLAN

1 REMOVE AND REPLACE EXISTING DIFFUSER

AND FLEX DUCT. ANY FLEX DUCT RUNOUT

SHALL NOT EXCEED 5 FEET.

2 REMOVE AND REPLACE EXISTING GRILLE. SEE

NEW WORK FOR LOCATION.

3 EXISTING VAV BOX TO BE REUSED. REMOVE

EXISTING CONTROLS AND REPLACE WITH NEW

DDC CONTROLS. SEE SPECS FOR DETAILS.

Revisions: Date:

ARCHITECT/ENGINEER OF RECORD

A/E:

CONSULTANT

C&S Engineers, Inc.

2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com

Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com

Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com

TRIPLE C - THE A&E GROUP

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

(E)FTR (E)FTR

(E)FTR (E)FTR

(E)FTR (E)FTR

(E)FTR (E)R-1

(E)R-1

(E)R-1

(E)FTR

(E)FTR

(E)FTR

(E)FTR

(E)FTR (E)FTR (E)FTR

(E)FTR

(E)FTR

(E)R-1

(E)FTR

(E)R-1

407.A

407.B1

407.C1

407.D1

407.E

407.F

407.G1

407.H

407.I

407.J

407.K

407.L

407.M

407.N

407.14407.11 407.12.1407.12

407.9407.7

407.41407.4407.3407.21

J.39

J.40

J.41

407.H2

407.H1

407.13.1

OPEN OFFICE

RESTROOM

RESTROOM

OPEN OFFICE

OFFICE

3775B

MECH / ELEC

3 3

DEDUCT ALT 1:

REMOVE WORK

ASSOCIATED WITH

B407 NORTH.

DEDUCT ALT 2:

REMOVE WORK

ASSOCIATED WITH

B407 SOUTH.

DEDUCT ALT 2:

REMOVE WORK

ASSOCIATED WITH

B407 SOUTH.

DEDUCT ALT 2:

REMOVE WORK

ASSOCIATED WITH

B407 SOUTH.

DEDUCT ALT 2:

REMOVE WORK

ASSOCIATED WITH

B407 SOUTH.

A. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS

PRIOR TO BEGINNING WORK AND NOTIFY THE ARCHITECT/

ENGINEER OF ANY DISCREPANCIES BETWEEN THE "AS-

BUILT" CONDITIONS AND THESE DRAWINGS.

B. COORDINATE ALL DUCTWORK INSTALLATION WITH

GENERAL, PLUMBING, FIRE PROTECTION, AND ELECTRICAL

CONTRACTORS. INSTALL ALL DUCTWORK AS HIGH AS

POSSIBLE. PROVIDE ALL NECESSARY OFFSETS (DROPS

AND RISES) TO KEEP DUCTWORK TIGHT TO THE

STRUCTURE ABOVE. OFFSET DUCTWORK TO AVOID

BEAMS

C. REFER TO AND COORDINATE WITH THE ARCHITECTURAL

PLANS FOR CEILING TYPES, HEIGHTS, SOFFIT AREAS, AND

ELEVATIONS FOR INSTALLATION OF NEW VENTILATION

DUCTWORK, EQUIPMENT, ETC.

D. THIS CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND

RE-INSTALLING OF EXISTING CEILING TILE NOT REMOVED

BY THE GENERAL CONTRACTOR FOR THE INSTALLATION

OF NEW VENTILATION DUCTWORK, EQUIPMENT, ETC.

VERIFY WITH ARCHITECTURAL PLANS FOR CEILING WORK

BY THE GENERAL CONTRACTOR. ANY CEILING TILE OR

GRID DAMAGED DURING CONSTRUCTION SHALL BE

REPLACED WITH NEW BY THIS CONTRACTOR.

E. THIS CONTRACTOR SHALL OPEN ALL EXISTING WALLS

AND/ OR CEILINGS FOR INSTALLATION OF NEW

VENTILATION DUCTWORK, EQUIPMENT, ETC. AS REQUIRED.

PATCH WALLS AND OR CEILINGS TO MATCH EXISTING.

F. MAINTAIN 3'-0" CLEAR SPACE IN FRONT OF ALL

ELECTRICAL, CONTROL, AND ACCESS PANELS FOR

ACCESSIBILITY.

G. ALL DAMPERS, ETC. SHALL BE INSTALLED IN ACCESSIBLE

CEILINGS.

H. FIRE CAULK DUCT PENTERATIONS AT RATED WALLS,

CEILING, AND FLOORS. REFER THE ARCHITECTURE SHEET

GI101, GI102, AND GI104 FOR FIRE RATINGS.

I. CONTRACTOR SHALL MAINTAIN ALL RECOMENDED

EQUIPMENT CLEARANCES.

J. REFER TO ARCHITECTURAL PLAN FOR FIRE RATED WALL /

PARTITION / FLOOR / CEILING / ASSEMBLY LOCATIONS.

N

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMP

321 4 5 6 7 8 9 10

GENERAL NOTES

KEYNOTES

B407 KEY PLAN

AREA A

KEY PLAN

ARCHITECT/ENGINEER OF RECORD

A/E:

CONSULTANT

C&S Engineers, Inc.

2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com

Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com

Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com

B

IM

/6

-3

B

E x p a n d

R e lo c a te

U rg e n t

C a re A n d

R e n o v a te s t F lo o r P a ti e n t C a re

/6

-3

.4

.M

E P

.r v t

/2

/2

:0

:1

A

M

MD103-407

B407 - LEVEL 3 - HVAC DEMOLITION

PLAN

Expand and Renovate B400 for

Urgent and Primary Care

500 E Veterans St, Tomah, WI 54660

676-19-327

400/407

05/20/2021 K.LEITCH P.KOTTA

TRIPLE C - THE A&E GROUP

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

ISSUED FOR

CONSTRUCTION

SCALE: 1/8" = 1'-0"

F1

B407 - LEVEL 3 - HVAC DEMOLITION PLAN

1 CONTRACTOR SHALL DISCONNECT/REMOVE

EXISTING RADIATION COVER AND PREP

EQUIPMENT FOR NEW COVER.

2 EXISTING WINDOW TO BE REMOVED AND

REPLACED WITH LOUVER. PREPARE OPENING

FOR LOUVER CONNECTION.

3 REMOVE EXISTING PNEUMATIC ACTUATOR

SERVING STEAM RADIATOR AND PREPARE

FOR FUTURE WORK. SEE MP203-407 FOR

DETAILS.

Revisions: Date:

ARCHITECT/ENGINEER OF RECORD

A/E:

CONSULTANT

C&S Engineers, Inc.

2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com

Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com

Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com

TRIPLE C - THE A&E GROUP

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

M

L

K.3

K

J.4

J.3

J

I.5

I.2

I

H.1

H

G

F.1

F

E

D

C

B

A

(E)2 1/2"

(E)2 1/2"

(E)2 1/2"

(E)2 1/2"

5" HHWR

5" HHWS

(E)5" HHWS UP

(E)5" HHWR UP

2 1/2" HHWR UP

2 1/2" HHWS UP

A. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR

TO BEGINNING WORK AND NOTIFY THE ARCHITECT/ ENGINEER

OF ANY DISCREPANCIES BETWEEN THE "AS-BUILT" CONDITIONS

AND THESE DRAWINGS.

B. COORDINATE ALL HVAC PIPING INSTALLATION WITH GENERAL,

PLUMBING, FIRE PROTECTION, VENTILATION, AND ELECTRICAL

CONTRACTORS. INSTALL ALL HVAC PIPING AS HIGH AS

POSSIBLE. PROVIDE ALL NECESSARY OFFSETS (DROPS AND

RISES) TO KEEP HVAC PIPING TIGHT TO THE STRUCTURE OR

DUCTWORK ABOVE. OFFSET HVAC PIPING TO AVOID BEAMS.

C. REFER TO AND COORDINATE WITH THE ARCHITECTURAL PLANS

FOR CEILING TYPES, HEIGHTS, SOFFIT AREAS, AND ELEVATIONS

FOR INSTALLATION OF NEW HVAC PIPING, EQUIPMENT, ETC.

D. THIS CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND RE-

INSTALLING OF EXISTING CEILING TILE NOT REMOVED BY THE

GENERAL CONTRACTOR FOR THE INSTALLATION OF NEW HVAC

PIPING, EQUIPMENT, ETC. VERIFY WITH ARCHITECTURAL PLANS

FOR CEILING WORK BY THE GENERAL CONTRACTOR. ANY

CEILING TILE OR GRID DAMAGED DURING CONSTRUCTION SHALL

BE REPLACED WITH NEW BY THIS CONTRACTOR.

E. THIS CONTRACTOR SHALL OPEN ALL EXISTING WALLS AND/OR

CEILINGS TO INSTALL NEW HVAC PIPING, EQUIPMENT, ETC. AS

REQUIRED. PATCH WALLS AND/OR CEILINGS TO MATCH

EXISTING.

F. MAINTAIN 3'-0" CLEAR SPACE IN FRONT OF ALL ELECTRICAL,

CONTROL, AND ACCESS PANELS FOR ACCESSIBILITY.

G. ALL SHUT-OFF VALVES, CONTROL VALVES, STRAINERS, ETC...

SHALL BE INSTALLED IN ACCESSIBLE CEILINGS.

H. PROVIDE 1/2" DRAIN VALVE AT ALL LOW POINTS OF EACH

SYSTEM TO ENABLE COMPLETE DRAINAGE. PROVIDE 1/2" VENT

VALVES AT ALL HIGH POINTS OF EACH SYSTEM TO ENABLE

COMPLETE VENTING.

I. REFER TO HVAC PIPING DETAILS ON SHEET 1/M502 FOR

ADDITIONAL INFORMATION ON INDIVIDUAL TERMINAL DEVICES

AND COILS.

J. ALL CONTROL VALVES ON THE HEATING DEVICES SHALL BE 2-

WAY UNLESS OTHERWISE NOTED.

K. FIRE CAULK PIPE PENTERATIONS AT RATED WALLS, CEILING,

AND FLOORS. REFER THE ARCHITECTURE SHEET GI101, GI102,

AND GI104 FOR FIRE RATINGS.

L. ELEMENTS SHOWN IN DARK LINEWEIGHT ARE NEW. ELEMENTS

SHOWN IN LIGHT LINEWEIGHT ARE EXISTING.

N

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMP

321 4 5 6 7 8 9 10

GENERAL NOTES

KEY PLAN

KEYNOTES

AREA A

B400 KEY PLAN

AREA B

AREA

A1

AREA C

ARCHITECT/ENGINEER OF RECORD

A/E:

CONSULTANT

C&S Engineers, Inc.

2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com

Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com

Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com

B

IM

/6

-3

B

E x p a n d

R e lo c a te

U rg e n t

C a re A n d

R e n o v a te s t F lo o r P a ti e n t C a re

/6

-3

.4

.M

E P

.r v t

/2

/2

:0

:2

A

M

MD200

B400 - FOUNDATION - HVAC PIPING

DEMOLITION PLAN

Expand and Renovate B400 for

Urgent and Primary Care

500 E Veterans St, Tomah, WI 54660

676-19-327

400/407

05/20/2021 K.LEITCH P.KOTTA

2508 29th Avenue NE

Mat Perkins

ISSUED FOR

CONSTRUCTION

SCALE: 1/8" = 1'-0"

F1

B400 - FOUNDATION - HVAC PIPING PLAN

1 REMOVE 2-1/2" HHWR AND CAP AT POINT

SHOWN ON PLAN.

2 REMOVE 2-1/2" HHWS AND CAP AT POINT

SHOW ON PLAN.

3 REMOVE 2-1/2" HHWS/R AT POINT AS SHOW

ON PLAN AND PREPARE FOR FUTURE

CONNECTION.

1 REMOVE 2-1/2" HHWR AND CAP AT POINT

SHOWN ON PLAN.

2 REMOVE 2-1/2" HHWS AND CAP AT POINT

SHOW ON PLAN.

3 REMOVE 2-1/2" HHWS/R AT POINT AS SHOW

ON PLAN AND PREPARE FOR FUTURE

CONNECTION.

Revisions: Date:

ARCHITECT/ENGINEER OF RECORD

A/E:

CONSULTANT

C&S Engineers, Inc.

2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com

Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com

Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com

TRIPLE C - THE A&E GROUP

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

T

T

T

T T

T

T

T

T

T

T

T

T

T

T

TT

T

T

T

T

T

T

T

T

T T

T

T

TT

T

T

T

T

T

TT

T

TT

1 2 3 4 5 6 6.1 7 7.8 8 9 10 11 11.2 12 13 14 18171615

M.3

M

L

K.3

K

J.4

J.3

J

I.5

I.2

I

H.1

H

G

F.1

F

E

D

C

B

A

(E)2" HHWS

(E)2" HHWR

(E)3/4" HHWR

(E)1 1/2" HHWR

(E)1 1/4" HHWS

(E)1 1/2" HHWS

(E)3/4" HHWR

(E)1" HHWR

(E)1 1/4" HHWR

(E)1 1/2" HHWS

(E)1 1/4" HHWR

(E)1 1/4" HHWS

(E)2" HHWR

(E)1" HHWS

(E)2" HHWR

(E)2" HHWR

(E)2" HHWR

(E)2" HHWS

(E)1 1/4" HHWS

(E)2"

(E)2"

(E)1 1/4" HHWR

(E)1" LPS(#) DN

(E)1 1/4" LPS(#)

(E)3" CHWR DN

(E)3" CHWS DN

(E)3" CHWR

(E)3" CHWS

(E)3-15

(E)3-13

(E)3-12

(E)3-14

(E)3-10 (E)3-9

(E)3-11

(E)3-6

(E)3-7

(E)3-8

REMOVE AHU,

CONTROLS,

AND PIPIPNG

(E)1-5

(E)3-5

(E)3-3

(E)3-4

(E)3-1

(E)3-2

(E)1-1

(E)1-2

(E)1-3

(E)1-6

(E)1-7

(E)1-8

(E)1-10

(E)1-12

(E)1-13

(E)1-9

(E)1-11

(E) AH-1

5 5

5 5

(E)

COOLING

TOWER

EXAM

EXAM

EXAM

OFFICE

OFFICE

OFFICE

OFFICE

EXAM

OFFICE

OFFICE

DIRTY UTILTIY

OFFICE

WAITING

NURSE STATION

OFFICE

EXAM

CONFERENCE

EXAM

EXAM

EXAM

OFFICE

OFFICE

WOMEN

VISITOR

TOILET

TLT

MECH

IT

OFFICE

OFFICE

OFFICE

EXAM

STAIR

WAITING / CIRCULATION

EXAM

EXAM

EXAM

NURSE STATION

1085 EXAM

EXAM

WOMEN TLT

EXAM

EXAM

OFFICE

STORAGE

1096A

STAFF TOILET

1094 STAFF TOILET

AMBULANCE GARAGE

A. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR

TO BEGINNING WORK AND NOTIFY THE ARCHITECT/ ENGINEER

OF ANY DISCREPANCIES BETWEEN THE "AS-BUILT" CONDITIONS

AND THESE DRAWINGS.

B. COORDINATE ALL HVAC PIPING INSTALLATION WITH GENERAL,

PLUMBING, FIRE PROTECTION, VENTILATION, AND ELECTRICAL

CONTRACTORS. INSTALL ALL HVAC PIPING AS HIGH AS

POSSIBLE. PROVIDE ALL NECESSARY OFFSETS (DROPS AND

RISES) TO KEEP HVAC PIPING TIGHT TO THE STRUCTURE OR

DUCTWORK ABOVE. OFFSET HVAC PIPING TO AVOID BEAMS.

C. REFER TO AND COORDINATE WITH THE ARCHITECTURAL PLANS

FOR CEILING TYPES, HEIGHTS, SOFFIT AREAS, AND ELEVATIONS

FOR INSTALLATION OF NEW HVAC PIPING, EQUIPMENT, ETC.

D. THIS CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND RE-

INSTALLING OF EXISTING CEILING TILE NOT REMOVED BY THE

GENERAL CONTRACTOR FOR THE INSTALLATION OF NEW HVAC

PIPING, EQUIPMENT, ETC. VERIFY WITH ARCHITECTURAL PLANS

FOR CEILING WORK BY THE GENERAL CONTRACTOR. ANY

CEILING TILE OR GRID DAMAGED DURING CONSTRUCTION SHALL

BE REPLACED WITH NEW BY THIS CONTRACTOR.

E. THIS CONTRACTOR SHALL OPEN ALL EXISTING WALLS AND/OR

CEILINGS TO INSTALL NEW HVAC PIPING, EQUIPMENT, ETC. AS

REQUIRED. PATCH WALLS AND/OR CEILINGS TO MATCH

EXISTING.

F. MAINTAIN 3'-0" CLEAR SPACE IN FRONT OF ALL ELECTRICAL,

CONTROL, AND ACCESS PANELS FOR ACCESSIBILITY.

G. ALL SHUT-OFF VALVES, CONTROL VALVES, STRAINERS, ETC...

SHALL BE INSTALLED IN ACCESSIBLE CEILINGS.

H. PROVIDE 1/2" DRAIN VALVE AT ALL LOW POINTS OF EACH

SYSTEM TO ENABLE COMPLETE DRAINAGE. PROVIDE 1/2" VENT

VALVES AT ALL HIGH POINTS OF EACH SYSTEM TO ENABLE

COMPLETE VENTING.

I. REFER TO HVAC PIPING DETAILS ON SHEET 1/M502 FOR

ADDITIONAL INFORMATION ON INDIVIDUAL TERMINAL DEVICES

AND COILS.

J. ALL CONTROL VALVES ON THE HEATING DEVICES SHALL BE 2-

WAY UNLESS OTHERWISE NOTED.

K. FIRE CAULK PIPE PENTERATIONS AT RATED WALLS, CEILING,

AND FLOORS. REFER THE ARCHITECTURE SHEET GI101, GI102,

AND GI104 FOR FIRE RATINGS.

L. ELEMENTS SHOWN IN DARK LINEWEIGHT ARE NEW. ELEMENTS

SHOWN IN LIGHT LINEWEIGHT ARE EXISTING.

N

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMP

321 4 5 6 7 8 9 10

GENERAL NOTES

KEY PLAN

KEYNOTES

AREA A

B400 KEY PLAN

AREA B

AREA

A1

AREA C

ARCHITECT/ENGINEER OF RECORD

A/E:

CONSULTANT

C&S Engineers, Inc.

2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com

Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com

Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com

B

IM

/6

-3

B

E x p a n d

R e lo c a te

U rg e n t

C a re A n d

R e n o v a te s t F lo o r P a ti e n t C a re

/6

-3

.4

.M

E P

.r v t

/2

/2

:0

:2

A

M

MD201

B400 - LEVEL 1 - HVAC PIPING

DEMOLITION PLAN

Expand and Renovate B400 for

Urgent and Primary Care

500 E Veterans St, Tomah, WI 54660

676-19-327

400/407

05/20/2021 K.LEITCH P.KOTTA

TRIPLE C - THE A&E GROUP

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

ISSUED FOR

CONSTRUCTION

SCALE: 1/8" = 1'-0"

F1

B400 - LEVEL 1 - HVAC PIPING DEMOLITION PLAN

1 REMOVE EXISTING CONDENSATE

CONNECTED TO EXISTING OUTSIDE AIR

LOUVER.

2 REMOVE HWS/R BRANCH BACK TO MAIN.

CAP AND SEAL WATER TIGHT.

3 REMOVE EXISTING CONVECTOR, PIPING,

AND FITTINGS BACK TO MAIN. CAP AND SEAL

MAIN WATER TIGHT.

4 REMOVE EXISTING THERMOSTAT AND

CONTROL WIRING. REMOVE ASSOCIATED

EQUIPMENT, GRAPHICS AND CONTROL

POINTS FROM BAS.

5 REMOVE EXISTING THERMOSTAT AND

CONTROL WIRING. WHERE APPLICABLE,

REUSE EXISTING ROUGH-IN.

6 REMOVE CHILLED WATER STEAM, AND

CONDENSATE PIPING BACK TO MAIN. CAP

AND SEAL WATER TIGHT.

Revisions: Date:

ARCHITECT/ENGINEER OF RECORD

A/E:

CONSULTANT

C&S Engineers, Inc.

2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com

Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com

Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com

TRIPLE C - THE A&E GROUP

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

T T

T

T T

T

T

T

T

T

T T

T

TTT

T

T

T

T

TTT

T T

T

T

T T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

TTT

T T

TT

T

T

T

T

T

T

T

T

T

T

T

1 2 3 4 5 6 6.1 7 7.8 8 9 9.1 9.9 10 11 11.2 12 13 14 18171615

M.3

M

L

K.3

K

J.4

J.3

J

I.5

I.2

I

H.1

H

G

F.1

F

E

D

C

B

A

(E)2

(E)4

(E)5

(E)1

(E)3

(E)10

(E)8

(E)3-18

(E)3-19

(E)3-20

(E)2" HHWS

(E)2" HHWR

(E)

COOLING

TOWER

(E)3-41

(E)1 1/2" HHWS

(E)1 1/4" HHWR

(E)1 1/2" HHWS

(E)1 1/4" HHWR

(E)3/4" HHWR

(E)3/4" HHWS

(E)3/4" HHWR

(E)3/4" HHWS

(E)3/4" HHWS(E)3/4" HHWR

(E)3/4" HHWR

(E)3/4" HHWS

(E)1 1/4" HHWS

(E)1 1/4" HHWR

(E)3/4" HHWS

(E)3/4" HHWR

(E)3/4" HHWS

(E)3/4" HHWR

(E)1 1/2" HHWR

(E)1 1/4" HHWS

(E)FTR

(E)FTR

(E)FTR (E)FTR

(E)FTR

(E)FTR

(E)3/4" HHWR(E)3/4" HHWS

(E)1 1/4" HHWR

(E)1 1/2" HHWS

(E)FTR

(E)3/4" HHWR

(E)3/4" HHWS

(E)3/4" HHWR

(E)3/4" HHWS

(E)FTR

(E)1 1/2" HHWS

(E)1" HHWR(E)3/4"

(E)3/4"

(E)3/4"

(E)3/4"

(E)3/4"

(E)3/4"

(E)3/4" HHWR

(E)FTR

(E)3/4" HHWS

(E)1" HHWS

(E)1 1/2" HHWR

(E)3/4" HHWR

(E)FTR

(E)3/4" HHWS (E)3/4"

(E)3/4"

(E)FTR

(E)1" HHWS

(E)1 1/2" HHWR

(E)3/4" HHWR

(E)3/4" HHWS

(E)FTR

(E)3/4" HHWR (E)3/4" HHWS

(E)3/4" HHWS

(E)1 1/2" HHWR

(E)FTR

(E)3/4" HHWS (E)3/4" HHWR

(E)2" HHWR

(E)2" HHWS

(E)2" HHWS

(E)FTR

(E)3/4" HHWS (E)3/4" HHWR

(E)3/4" HHWR

(E)1 1/2" HHWS

(E)3/4" HHWS

(E)FTR

(E)3/4" HHWR

(E)2 1/2" CHWS(E)2 1/2" CHWR

(E)2 1/2" HHWR

(E)2 1/2" HHWS

(E)1 1/2" HHWS

(E)1 1/2" HHWR

(E)1" HHWR

(E)1" HHWS

(E)1" HHWR

(E)1" HHWS

(E)3/4" HHWS

(E)3/4" HHWR

(E)1" HHWR

(E)1" HHWS

(E)1 1/2" HHWR

(E)1 1/2" HHWR

(E)1" HHWS

(E)1" HHWR

(E)3/4" HHWR

(E)3/4" HHWS

(E)3" HHWR

(E)3" HHWS

(E)3" HHWR

(E)3" HHWS

(E)1 1/4" HHWR (E)3" HHWR

(E)1" HHWR

(E)3" HHWS

OFFICE

UNOCCUPIED

CLEAN UTILITY

LAB

CORRIDOR

OC24A

MECHANICAL

EXAM TREATMENT

OFFICE

2015A

TOILET, STAFF

2030A

UTILITY ROOM, SOILED

TOILET

LOCKER ROOM

LAB

TREATMENT ROOM

EXAM/ TREATMENT ROOM

EXAM/ TREATMENT ROOM

TREATMENT ROOM

EXAM/TREATMENT ROOM

TREATMENT ROOM

STAIR

S9

OFFICE, TECHNICIAN

A. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR

TO BEGINNING WORK AND NOTIFY THE ARCHITECT/ ENGINEER

OF ANY DISCREPANCIES BETWEEN THE "AS-BUILT" CONDITIONS

AND THESE DRAWINGS.

B. COORDINATE ALL HVAC PIPING INSTALLATION WITH GENERAL,

PLUMBING, FIRE PROTECTION, VENTILATION, AND ELECTRICAL

CONTRACTORS. INSTALL ALL HVAC PIPING AS HIGH AS

POSSIBLE. PROVIDE ALL NECESSARY OFFSETS (DROPS AND

RISES) TO KEEP HVAC PIPING TIGHT TO THE STRUCTURE OR

DUCTWORK ABOVE. OFFSET HVAC PIPING TO AVOID BEAMS.

C. REFER TO AND COORDINATE WITH THE ARCHITECTURAL PLANS

FOR CEILING TYPES, HEIGHTS, SOFFIT AREAS, AND ELEVATIONS

FOR INSTALLATION OF NEW HVAC PIPING, EQUIPMENT, ETC.

D. THIS CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND RE-

INSTALLING OF EXISTING CEILING TILE NOT REMOVED BY THE

GENERAL CONTRACTOR FOR THE INSTALLATION OF NEW HVAC

PIPING, EQUIPMENT, ETC. VERIFY WITH ARCHITECTURAL PLANS

FOR CEILING WORK BY THE GENERAL CONTRACTOR. ANY

CEILING TILE OR GRID DAMAGED DURING CONSTRUCTION SHALL

BE REPLACED WITH NEW BY THIS CONTRACTOR.

E. THIS CONTRACTOR SHALL OPEN ALL EXISTING WALLS AND/OR

CEILINGS TO INSTALL NEW HVAC PIPING, EQUIPMENT, ETC. AS

REQUIRED. PATCH WALLS AND/OR CEILINGS TO MATCH

EXISTING.

F. MAINTAIN 3'-0" CLEAR SPACE IN FRONT OF ALL ELECTRICAL,

CONTROL, AND ACCESS PANELS FOR ACCESSIBILITY.

G. ALL SHUT-OFF VALVES, CONTROL VALVES, STRAINERS, ETC...

SHALL BE INSTALLED IN ACCESSIBLE CEILINGS.

H. PROVIDE 1/2" DRAIN VALVE AT ALL LOW POINTS OF EACH

SYSTEM TO ENABLE COMPLETE DRAINAGE. PROVIDE 1/2" VENT

VALVES AT ALL HIGH POINTS OF EACH SYSTEM TO ENABLE

COMPLETE VENTING.

I. REFER TO HVAC PIPING DETAILS ON SHEET 1/M502 FOR

ADDITIONAL INFORMATION ON INDIVIDUAL TERMINAL DEVICES

AND COILS.

J. ALL CONTROL VALVES ON THE HEATING DEVICES SHALL BE 2-

WAY UNLESS OTHERWISE NOTED.

K. FIRE CAULK PIPE PENTERATIONS AT RATED WALLS, CEILING,

AND FLOORS. REFER THE ARCHITECTURE SHEET GI101, GI102,

AND GI104 FOR FIRE RATINGS.

L. ELEMENTS SHOWN IN DARK LINEWEIGHT ARE NEW. ELEMENTS

SHOWN IN LIGHT LINEWEIGHT ARE EXISTING.

N

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMP

321 4 5 6 7 8 9 10

GENERAL NOTES

KEY PLAN

KEYNOTES

AREA A

B400 KEY PLAN

AREA B

AREA

A1

AREA C

ARCHITECT/ENGINEER OF RECORD

A/E:

CONSULTANT

C&S Engineers, Inc.

2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com

Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com

Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com

B

IM

/6

-3

B

E x p a n d

R e lo c a te

U rg e n t

C a re A n d

R e n o v a te s t F lo o r P a ti e n t C a re

/6

-3

.4

.M

E P

.r v t

/2

/2

:0

:3

A

M

MD202

B400 - LEVEL 2 - HVAC PIPING

DEMOLITION PLAN

Expand and Renovate B400 for

Urgent and Primary Care

500 E Veterans St, Tomah, WI 54660

676-19-327

400/407

05/20/2021 K.LEITCH P.KOTTA

TRIPLE C - THE A&E GROUP

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

ISSUED FOR

CONSTRUCTION

SCALE: 1/8" = 1'-0"

F1

B400 - LEVEL 2 - HVAC PIPING PLAN DEMOLITION PLAN

1 REMOVE EXISTING THERMOSTAT AND

CONTROL WIRING. WHERE APPLICABLE,

REUSE EXISTING ROUGH-IN.

2 REMOVE EXISTING THERMOSTAT SERVING

VAV BOX (E)3-41 AND PREPARE BOX FOR

FUTURE THERMOSTAT CONTROL WIRING.

Revisions: Date:

ARCHITECT/ENGINEER OF RECORD

A/E:

CONSULTANT

C&S Engineers, Inc.

2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com

Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com

Hinman Consulting Engineers 601 California Street…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .