ATTACHMENT 10 - Signage.pdf

PDF 3 MB Posted

Attached to
Y1DZ--Expand and Renovate B400 for Urgent and Primary Care (Minor) - Tomah
Solicitation number
36C77621B0009
Issued by

About this file

This solicitation is for a construction contract to expand and renovate an urgent and primary care facility at a Department of Veterans Affairs medical center. The contractor will be responsible for demolishing existing structures, preparing the site for construction, and performing all work required to complete the project in accordance with the drawings and specifications. This includes furnishing all labor, materials, equipment and performing demolition, site work, general construction, interior construction and finishes, mechanical, electrical and plumbing work. The solicitation was issued by the VA Technology Acquisition Center in Austin, Texas for work to be performed at the VA medical center in Tomah, Wisconsin. The response due date and contract award date are not provided in the solicitation summary.

View the file

Other files

File Type Posted
31 23 19 DEWATERING.pdf PDF
36C77621B0009 0003.pdf PDF
Drawings VF100 - VF101.pdf PDF
Technical Questions - FINAL - Tomah 8-2-21.pdf PDF
36C77621B0009 0002.pdf PDF
ATTACHMENT 17 - Construction Wage Rates - Monroe County - 7-9-21.pdf PDF
Site Visit Sign-in Sheet - Tomah - 9 AM - 7-12-21.pdf PDF
36C77621B0009 0001.pdf PDF
Site Visit Sign-in Sheet - Tomah - 10 AM - 7-13-21.pdf PDF
ATTACHMENT 20 - Site Visit Registration - Map.pdf PDF
36C77621B0009 - 6-29-21.pdf PDF
ATTACHMENT 15 - Fire Alarm.pdf PDF
ATTACHMENT 7 - Fire Protection.pdf PDF
ATTACHMENT 16 - Contractor Core Work Hours.pdf PDF
ATTACHMENT 17 - Construction Wage Rates - Monroe County - 5-14-21.pdf PDF
ATTACHMENT 12 - Furniture.pdf PDF
ATTACHMENT 4 - Electrical.pdf PDF
ATTACHMENT 13 - Civil.pdf PDF
ATTACHMENT 11 - Architectual.pdf PDF
ATTACHMENT 8 - Equipment.pdf PDF
ATTACHMENT 1 - Specifications Final 6-21-21.pdf PDF
ATTACHMENT 6 - Plumbing.pdf PDF
ATTACHMENT 2 - General.pdf PDF
ATTACHMENT 19 - Contractor Safety - Environmental Form.docx DOCX document
ATTACHMENT 18 - Limitations on Subcontracting - Construction.docx DOCX document
ATTACHMENT 5 - Mechanical.pdf PDF
ATTACHMENT 9 - Interiors.pdf PDF
ATTACHMENT 3 - Structural.pdf PDF
ATTACHMENT 14 - Hazard.pdf PDF
Show all 29

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

INTERIOR SIGN PLAQUE COLOR

REFERENCES

VA SIGNAGE DESIGN MANUAL

SIGN VENDOR TO REFERENCE VA SIGNAGE DESIGN MANUAL FOR COMPLETE

SPECIFICATIONS

https://www.cfm.va.gov/til/spclRqmts.asp#SIGN

SIGN SYMBOL LEGEND

PRIMARY SIGN

SECONDARY SIGN

CONFERENCE/TRAINING ROOM SIGN

RESTROOM - ALL

RESTROOM - MEN

RESTROOM - WOMEN

EXIT

DIRECTIONAL

1. LETTERFORMS SHALL BE HELVETICA, PER VA ADMINISTRATION STANDARDS. UPPER AND LOWER CASE SHALL BE USED ON ALL DIRECTIONAL TRAFFIC AND PEDESTRIAN SIGNS, UNLESS NOTED.

HELVETICA CONDENSED MEDIUM FOR ALL OVERHEAD SIGNS. PROPOSED AND REFURBISHED SITE

SIGNAGE SHALL MATCH EXISTING SIGN PROGRAM, INCLUDING FONT, GRAPHICS, CONSTRUCTION, DETAILING, MATERIALS AND COLORS.

2. SIGN CONTRACTOR SHALL REVIEW SIGN LOCATIONS PRIOR TO INSTALLATION WITH COR TO

COORDINATE WITH LIGHTING SYSTEM, SIGN AND LIGHT LOCATIONS PER SPECIFICATIONS.

3. SIGNS SHALL BE MOUNTED LEVEL AND PLUMB, UNLESS NOTED.

4. WHERE TWO (2) SIGNS ARE MOUNTED BACK-TO-BACK, SMALLEST L DIMENSION SHALL INCREASE TO

MATCH LARGEST L DIMENSION.

5. MAXIMUM BOLT INSERT EMBEDMENT LENGTH 1-1/4" INTO CONCRETE STRUCTURE, UNLESS NOTED.

6. DO NOT SCALE DRAWINGS.

7. BACKS AND EDGES OF ALL ALUMINUM SIGNS MOUNTED DIRECTLY TO STRUCTURE SHALL BE

PAINTED WHITE TO PREVENT CATHODIC REACTION.

8. ILLUMINATED SIGNS TO BE U.L. LISTED OR APPROVED EQUIVALENT.

9. REFLECTIVE GRAPHICS AND COPY COLORS ARE 3M. ALL NON-REFLECTIVE COLORS ARE PANTONE

OR EQUAL TO SHERWIN WILLIAMS.

10. SEE DEPARTMENT OF VETERANS AFFAIRS SIGNAGE DESIGN GUIDE, PG-18-12 FOR ADDITIONAL

INFORMATION INCLUDING SIGN TYPE, SIZE, COLORS AND MOUNTING DETAILS NOTED IN SCHEDULE.

11. HANG SIGN FROM OUTSIDE FACE OF BEAM.

12. HEIGHT OF SIGNS AS INDICATED IS TO BOTTOM OF THE SIGN.

13. COORDINATE BLIND AND NON-AMBULATORY PEDESTRIAN SIGNAGE AND TACTILE SURFACING

REQUIREMENTS WITH CAMPUS STANDARDS AND PG-18-12.

14. ALL SIGNS INDICATED TO BE RELOCATED SHALL BE REMOVED IN THEIR ENTIRETY (INCLUDING

CONCRETE FOUNDATIONS), REFURBISHED OFF SITE TO LIKE NEW CONDITION, HAVE NEW MESSAGE INSTALLED AS SCHEDULED, AND BE INSTALLED IN THEIR FINAL LOCATION BEFORE COMPLETION OF THE PROJECT. INCLUDE NEW FOUNDATION (TO MATCH EXISTING) IN BID PRICE FOR ALL RELOCATED

SIGNS.

15. FOR ALL SIGNS IN THIS PROJECT, PROVIDE ENGINEERING FOR FOUNDATIONS AND ATTACHMENT

CONNECTIONS TO MEET LOCAL CODES AND ORDINANCES FOR WIND LOADING AND OTHER

APPLICABLE SAFETY AND SOILS REQUIREMENTS.

16. DIRECTIONAL SIGNAGE: ARROW DIRECTION AND PLACEMENT IS DEPENDENT ON FINAL SIGN LOCATIONS. ALL SIGN ARROW ORIENTATION IS TO BE COORDINATED WITH ARCHITECT AND OWNER

PRIOR TO FABRICATION.

17. VA LOGO: CONTRACTOR SHALL OBTAIN DIGITAL FILE OF CURRENT VA LOGO FROM VA STAFF PRIOR

TO FABRICATION OF ANY SIGNS INCORPORATING THE VA LOGO.

18. ANY EXISTING SIGNS NOT SHOWN ON PLAN ARE "EXISTING TO REMAIN". IN THE CASE WHEN AN EXISTING SIGN IS IN CONFLICT WITH FINAL PROJECT BUILDINGS OR SITE ELEMENTS, CONTRACTOR SHALL SALVAGE SIGNAGE FOR OWNER. IN THE CASE WHEN CONSTRUCTION ACTIVITIES CONFLICT

WITH AN EXISTING SIGN LOCATION, THE SIGN SHALL BE REMOVED, PUT INTO STORAGE,

REFURBISHED AND PLACED BACK IN ITS ORIGINAL LOCATION PRIOR TO COMPLETION OF THE

PROJECT. INCLUDE THIS SCOPE OF WORK WITHIN THE BID PRICE.

19. BID PRICE SHALL INCLUDE REFURBISHMENT TO LIKE NEW CONDITION, REMESSAGING AND

RELOCATION FOR (2) ADDITIONAL 5'x4' POST & PANEL SITE SIGNS (2 SIDED), BEYOND WHAT IS

INDICATED WITHIN THESE DOCUMENTS, INCLUDING INSTALLATION AND FOUNDATIONS.

20. BID PRICE SHALL INCLUDE (1) ADDITIONAL SIGN #6 BEYOND WHAT IS INDICATED WITHIN THESE

DOCUMENTS, INCLUDING INSTALLATION AND FOUNDATIONS.

21. FOR EXISTING SIGNS THAT ARE SCHEDULED WITH PROPOSED MESSAGES, REMOVE THE ENTIRE

EXISTING MESSAGE, THOROUGHLY CLEAN THE PANEL AND INSTALL THE NEW MESSAGE. IF

SHADOWING OF ANY KIND REMAINS AFTER PANEL IS CLEANED, THEN PANEL MUST BE REMOVED

AND REFINISHED PRIOR TO NEW MESSAGE INSTALLATION.

22. FOR EXISTING SIGNS THAT HAVE NO PROPOSED MESSAGE IN THE SCHEDULE, THE EXISTING

MESSAGE SHALL REMAIN UNCHANGED, U.N.O.

23. MESSAGES INDICATED IN SCHEDULE WITH UNDERLINED TEXT REPRESENT LINES SEPARATING

TEXT.

24. DESIGN INTENT IS THAT TEXT IS ORIENTED AS INDICATED IN PROPOSED MESSAGE COLUMN OF THE SIGN SCHEDULE. ORIENTATION OF MESSAGE SHALL BE CONSISTENT WITH EXISTING SITE SIGNS.

FINAL LAYOUT COORDINATION TO BE PERFORMED WITH ARCHITECT DURING THE SHOP DRAWING

PROCESS.

25. DESIGN INTENT IS THAT SIZE OF LETTERING AND GRAPHICS ARE TO MATCH THAT OF THE MESSAGE

BEING REPLACED.

26. ALL SIGNS REQUIRING PANEL REFURBISHMENT SHALL ALSO HAVE "VA" LOGO REPLACED.

27. CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL SIGNS FOR THIS PROJECT. QUANTITIES INDICATED

IN SCHEDULES DO NOT REFLECT TOTAL QUANTITIES IN PROJECT. REFERENCE ALL DRAWINGS AND

SPECIFICATIONS TO UNDERSTAND ENTIRE SIGNAGE SCOPE.

28. TEXT SIZE ON SIGNAGE TO BE MODIFIED TO ACCOMMODATE VERBIAGE FITTING WITHIN SIGN LIMITS.

29. MANUFACTURER'S TRADE NAMES AND NUMBERS USED HEREIN ARE ONLY TO IDENTIFY COLORS, FINISHES, TEXTURES AND PATTERNS AS THE BASIS OF THE DESIGN. PRODUCTS OF AUTHORIZED

EQUAL MANUFACTURER'S EQUIVALENT TO COLORS, FINISHES, TEXTURES AND PATTERNS OF

MANUFACTURERS LISTED THAT MEET REQUIREMENTS OF DRAWINGS AND TECHNICAL

SPECIFICATIONS IN EVERY RESPECT MAY BE ACCEPTABLE WITH SUBMITTAL OF A COMPLETED

SUBSTITUTION REQUEST CONTAINING ALL PRODUCT DATA, TESTING AND ACTUAL SAMPLES AND

UPON APPROVAL IN WRITING BY CONTRACTING OFFICER.

30. FOR ANY SIGN NOTED TO BE RETURNED TO OWNER, CONTRACTOR SHALL COMPLETELY REMOVE

CONCRETE FOUNDATION PRIOR TO TURNING OVER.

SIGN COLOR: A060518-

BK GLOOMY GREY

COPY OPTION:

DIRECT PRINT

COPY STYLE: HRC

HELVETICA REGULAR

COPY COLOR: 708

WHITE

COPY SIZE: 1-1/2, 3/4

EDGE RAIL COLOR AND

ACCENT STRIP COLOR:

704 BLACK

INSERT SIZE 11X17w

INSERT COLOR: 704

BLACK, 408 WHITE

INSERT COLOR:

A060518-BK GLOOMY

GREY

FRAME COLOR: 101

SATIN

COPY STYLE: HRC

HELVETICA REGULAR

COPY COLOR: 708

WHITE

COPY OPTION: BLANK

COPY OPTION: DIRECT

PRINT

COPY SIZE: 1

SIGN COLOR: A060518-BK

GLOOMY GREY

COPY OPTION: DIRECT

PRINT

COPY STYLE: HRC

HELVETICA REGULAR

COPY COLOR: 708

WHITE

COPY SIZE: 5/8, 3/8

SIGN COLOR: A060518-BK

GLOOMY GREY

COPY OPTION: DIRECT PRINT

COPY STYLE: HRC HELVETICA

REGULAR

COPY COLOR: 708 WHITE

COPY SIZE: 1-3/4, 3/4

SIGN COLOR: A060518-BK GLOOMY

GREY

COPY OPTION: TACTILE/BRAILLE,

DIRECT PRINT

COPY STYLE: HRC HELVETICA

REGULAR

COPY COLOR: 708 WHITE

COPY SIZE: 3/4, 5/8

SIGN COLOR: A060518-BK

GLOOMY GREY

COPY OPTION: DIRECT

PRINT

COPY STYLE: HRC

HELVETICA REGULAR

COPY COLOR: 708 WHITE

COPY SIZE: 2-3/4,

1-5/16

SIGN COLOR: A060518-BK

GLOOMY GREY

COPY OPTION: VINYL

COPY STYLE: SYMBOL, HRC

HELVETICA REGULAR

COPY COLOR: 708 WHITE

COPY SIZE: 5, 3/4

EDGE RAIL COLOR: 704 BLACK

FRAME COLOR: 101 SATIN

MOUNT OPTION: K-

PERPENDICULAR

DRY ERASE ACRYLIC

SIGN COLOR: A060518-BK

GLOOMY GREY

COPY OPTION:

PHOTOPOLYMER/

BRAILLE

COPY STYLE: HRC

HELVETICA REGULAR

COPY COLOR: 708 WHITE

COPY SIZE: 1-1/4

1/

4"

9"

3"

EDGE RAIL COLOR AND

ACCENT STRIP COLOR: 704

BLACK

COPY OPTION:

PHOTOPOLYMER/ BRAILLE

INSERT COLOR: A060518-BK

GLOOMY GREY

FRAME COLOR: 101 SATIN

COPY STYLE: HRC

HELVETICA REGULAR

COPY COLOR: 708 WHITE

1/

4"

9"

3"

EDGE RAIL COLOR AND

ACCENT STRIP COLOR: 704

BLACK

COPY OPTION:

PHOTOPOLYMER/ BRAILLE

INSERT COLOR: A060518-BK

GLOOMY GREY

FRAME COLOR: 101 SATIN

COPY STYLE: HRC HELVETICA

REGULAR

COPY COLOR: 708 WHITE

EDGE RAIL COLOR

AND ACCENT STRIP

COLOR: 704 BLACK

COPY OPTION:

PHOTOPOLYMER/

BRAILLE

INSERT COLOR:

A060518-BK

GLOOMY GREY

FRAME COLOR:

101 SATIN

COPY STYLE: HRC

HELVETICA REGULAR

COPY COLOR: 708

WHITE

SIGN COLOR: 735

RED

COPY OPTION:

DIRECT PRINT

COPY STYLE:

SYMBOL, HRC

HELVETICA

REGULAR

COPY COLOR: 708

WHITE

COPY SIZE: 5, 3/4

SIGN COLOR: A060518-BK

GLOOMY GREY

COPY OPTION:

VINYL

COPY STYLE: SYMBOL,

HRC HELVETICA

REGULAR

COPY COLOR:

708 WHITE

COPY SIZE: 5, 3/4

END CAP STYLE: SL,

SLIMLINE TREC

MOUNT OPTION: K-

PERPENDICULAR

SIGN COLOR: A060518-BK GLOOMY

GREY

COPY OPTION: PHOTOPOLYMER/ BRAILLE

COPY STYLE: HRC HELVETICA REGULAR

COPY COLOR: 708 WHITE

COPY SIZE: 1-1/4

EDGE RAIL COLOR: 704 BLACK

FRAME COLOR: 101 SATIN

MOUNT OPTION: D-SCREW

SIGN COLOR: A060518-BK

GLOOMY GREY

COPY OPTION: PHOTOPOLYMER/

BRAILLE

COPY STYLE: HRC HELVETICA

REGULAR

COPY COLOR: 708 WHITE

COPY SIZE: 1-1/4

EDGE RAIL COLOR: 704 BLACK

FRAME COLOR: 101 SATIN

MOUNT OPTION: D-SCREW

INSERT COLOR: 704 BLACK, 403

COOL GREY

SIGN COLOR: A060518-BK

GLOOMY GREY

COPY OPTION: DIRECT

PRINT

COPY STYLE: HRC

HELVETICA REGULAR

COPY COLOR: 708 WHITE

COPY SIZE: 2-3/4,

1-5/16

** SIGN IMAGE WAS NOT PROVIDED THEREFORE DOES ACCURATELY DEPICT CAMPUS STANDARDS

N

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

AREA A

B400 KEY PLAN

AREA B

AREA

A1

C&S Engineers, Inc.

2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com

Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: 612-249-5600 www.obernel.com

Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com

B

IM

/6

-3

B

E x p a n d

R e lo c a te

U rg e n t C a re

A n d

R e n o v a te s t F lo o r

P a ti e n t C a re

/6

-3

.B

.A

.r v t

/1

/2

:5

:5

A

M

AW001

SIGNAGE ABBREVIATIONS, SYMBOLS, GENERAL

NOTES & DETAILS

TRIPLE C - THE A&E GROUP

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

676-19-327

400/407

05/20/2021 M.PERKINS ENN

ISSUED FOR

CONSTRUCTION

Expand and Renovate B400 for Urgent and Primary Care

500 E Veterans St, Tomah, WI 54660

BUILDING SIGNAGE SCHEDULE

VERSION

TYPE COUNT DESCRIPTION

DETAIL

NUMBER INSTALLATION PROPOSED MESSAGE

BRAILLE OR

RAISED LETTERS

REQUIRED TEXT COLOR BACKGROUND COLOR

DIMENSIONS

COMMENTS

SIGN_

HEIGHT

SIGN_

WIDTH

MOUNTING

HEIGHT

2618 2 WALL MOUNTED DIRECTIONAL F1 / AW001 STAFF SPACES REFER TO PAGE 9-5-9 OF INTERIOR SIGNS DESIGN GUIDE DATED 12/2012 YES MATCH CAMPUS STANDARD MATCH CAMPUS STANDARDS 2' - 3" 1' - 5" 4' - 6"

IN-01.01.03 3 FIRE & EMERGENCY EXIT PLAN D1 / AW001 PUBLIC SPACES REFER TO PAGE 9-5-9 OF INTERIOR SIGNS DESIGN GUIDE DATED 12/2012 NO MATCH CAMPUS STANDARD MATCH CAMPUS STANDARDS 3 1/4" 9" 4' - 6"

IN-01.03 3 FIRE PROCEDURE SIGN E4 / AW001 PUBLIC SPACES REFER TO PAGE 8-5-7 OF CODE AND LIFE SAFETY SIGNS DESIGN GUIDE DATED 12/2012 NO MATCH CAMPUS STANDARD MATCH CAMPUS STANDARDS 9" 9" 5' - 0"

IN-01.05 6 FIRE DOOR E2 / AW001 PUBLIC SPACES REFER TO PAGE 9-5-7 OF INTERIOR SIGNS DESIGN GUIDE DATED 12/2012 NO MATCH CAMPUS STANDARD MATCH CAMPUS STANDARDS 9" 9" 5' - 0"

IN-01.10 3 STAIR IDENTIFICATION E5 / AW001 PUBLIC SPACES REFER TO PAGE 9-5-9 OF INTERIOR SIGNS DESIGN GUIDE DATED 12/2012 YES MATCH CAMPUS STANDARD MATCH CAMPUS STANDARDS 9" 9" 4' - 6"

IN-01.30 3 NO RE-ENTRY D2 / AW001 PUBLIC SPACES REFER TO PAGE 8-5-61 OF CODE AND LIFE SAFETY SIGNS DESIGN GUIDE DATED 12/2012 NO MATCH CAMPUS STANDARD MATCH CAMPUS STANDARDS 9" 9" 5' - 0"

IN-01.31 9 FLAG MOUNT FIRE EQUIPMENT F5 / AW001 PUBLIC SPACES REFER TO PAGE 9-5-27 OF INTERIOR SIGNS DESIGN GUIDE DATED 12/2012 NO MATCH CAMPUS STANDARD MATCH CAMPUS STANDARDS 9" 8" 5' - 0"

IN-05.07 29 PATIENT ROOM IDENTIFICATION WITH INSERT F4 / AW001 PATIENT ROOMS REFER TO PAGE 9-5-13 OF INTERIOR SIGNS DESIGN GUIDE DATED 12/2012 YES MATCH CAMPUS STANDARD MATCH CAMPUS STANDARDS 10 1/8" 11" 5' - 0"

IN-09.01 1 RESTROOM IDENTIFICATION-WOMEN B1 / AW001 RESTROOMS REFER TO PAGE 9-5-27 OF INTERIOR SIGNS DESIGN GUIDE DATED 12/2012 YES MATCH CAMPUS STANDARD MATCH CAMPUS STANDARDS 1' - 0 1/4" 9" 5' - 0"

IN-09.02 1 RESTROOM IDENTIFICATION-MEN B2 / AW001 RESTROOMS REFER TO PAGE 9-5-27 OF INTERIOR SIGNS DESIGN GUIDE DATED 12/2012 YES MATCH CAMPUS STANDARD MATCH CAMPUS STANDARDS 1' - 0 1/4" 9" 5' - 0"

IN-09.03 12 RESTROOM IDENTIFICATION B4 / AW001 RESTROOMS REFER TO PAGE 9-5-27 OF INTERIOR SIGNS DESIGN GUIDE DATED 12/2012 YES MATCH CAMPUS STANDARD MATCH CAMPUS STANDARDS 1' - 0 1/8" 8 1/2" 5' - 0"

IN-09.08 1 PICTOGRAM AND SYMBOL A1 / AW001 ALCOVE REFER TO PAGE 9-5-29 OF INTERIOR SIGNS DESIGN GUIDE DATED 12/2012 YES MATCH CAMPUS STANDARD MATCH CAMPUS STANDARDS 9" 9" 5' - 0"

IN-11.01 2 INFORMATIONAL OR INSTRUCTIONAL SIGN PRESSURIZED ROOMS REFER TO PAGE 9-5-33 OF INTERIOR SIGNS DESIGN GUIDE DATED 12/2012 YES MATCH CAMPUS STANDARD MATCH CAMPUS STANDARDS 9" 9" 5' - 0" VA DESIGNER TO SELECT

IN-13.01 4 FLAG MOUNT RESTROOM IDENTIFICATION B5 / AW001 RESTROOMS REFER TO PAGE 9-5-27 OF INTERIOR SIGNS DESIGN GUIDE DATED 12/2012 NO MATCH CAMPUS STANDARD MATCH CAMPUS STANDARDS 9" 9" 5' - 0"

IN-15.51C 1 CEILING MOUNTED DIRECTIONAL SIGN D4 / AW001 CORRIDOR REFER TO PAGE 9-5-951 OF INTERIOR SIGNS DESIGN GUIDE DATED 12/2012 YES MATCH CAMPUS STANDARD MATCH CAMPUS STANDARDS 6" 3' - 4" 7' - 0"

IN-39.1 10 SECONDARY ROOM IDENTIFICATION F1 / AW001 STAFF SPACES REFER TO PAGE 9-5-9 OF INTERIOR SIGNS DESIGN GUIDE DATED 12/2012 YES MATCH CAMPUS STANDARD MATCH CAMPUS STANDARDS 3" 8 1/2" 4' - 6"

IN-69.1 34 PRIMARY ROOM IDENTIFICATION WITH INSERT F2 / AW001 PUBLIC SPACES REFER TO PAGE 9-5-7 OF INTERIOR SIGNS DESIGN GUIDE DATED 12/2012 YES MATCH CAMPUS STANDARD MATCH CAMPUS STANDARDS 6 1/8" 8 1/2" 5' - 0"

Grand total: 124

SIGNAGE GENERAL NOTES

NOT USED

SIGNAGE IS FOR

REFERENCE ONLY.

VA DESIGNER TO REVIEW

SIGNAGE PLANS AND

PROCURE ALL SIGNAGE.

3" = 1'-0" E1

2618 SIGN DETAIL - DIRECTIONAL

3" = 1'-0" D1

IN-01.01.03 SIGN DETAIL -

FIRE & EMERGENCY EXIT

PLAN

3" = 1'-0" E4

IN-01.03 SIGN DETAIL - FIRE

PROCEDURE SIGN

3" = 1'-0"

E2

IN-01.05 SIGN DETAIL - FIRE

DOOR SIGN

3" = 1'-0"

E5

IN-01.10 SIGN DETAIL -

STAIR IDENTIFICATION SIGN

3" = 1'-0" D2

IN-01.30 SIGN DETAIL - NO

RE-ENTRY SIGN

3" = 1'-0" F5

IN-01.31 SIGN DETAIL - FLAG MOUNT FIRE EQUIPMENT

3" = 1'-0"

F4

IN-05.07 SIGN DETAIL -

EXAM ROOM

IDENTIFICATION

3" = 1'-0" B2

IN-09.01 SIGN DETAIL -

MENS RESTROOM SIGN

3" = 1'-0"

B1

IN-09.02 SIGN DETAIL -

WOMENS RESTROOM SIGN

3" = 1'-0"

B4

IN-09.03 SIGN DETAIL -

RESTROOM

IDENTIFICATION

3" = 1'-0" A1

IN-09.08 SIGN DETAIL -

PICTOGRAM

3" = 1'-0" B5

IN-13.01 SIGN DETAIL - FLAG MOUNT RESTROOM SIGN

3" = 1'-0" F1

IN-39.1 SIGN DETAIL -

SECONDARY ROOM

IDENTIFICATION

3" = 1'-0"

F2

IN-69.1 SIGN DETAIL -

PRIMARY ROOM

IDENTIFICATION

3" = 1'-0" D4

IN-15.51C SIGN DETAIL - CEILING MOUNT DIRECTIONAL

Revisions: Date:

ARCHITECTURAL SIGNAGE LEGEND

ARCHITECTURAL SHEET NOTES

1. REFER TO PLAN SHEETS FOR SIGNAGE LOCATION INFORMATION, REFER

TO SPECIFICATIONS FOR ADDITIONAL SIGNAGE, IDENTIFICATION AND

SYSTEMS / EQUIPMENT LABELING REQUIREMENTS.

2. REFER TO AW100 FOR SIGNAGE MESSAGE AND SCHEDULE

INFORMATION.

3. REFER TO AW100 FOR DETAILS AND SIGNAGE MOUNTING.

4. REFER TO "IN" SERIES SHEETS FOR ARCHITECTURAL INTERIOR FINISHES

AND PAINTS.

SIGN TYPE, SEE SCHEDULEXXX

MANDATORY POLICY SIGN DESIGNATIONS

IN-02.03 A

I Designates an interior sign.

N Identifies the sign is non-illuminated.

02 Two digit number identifies a particular sign type family .

.03 The two digit number, following the period, identifies a specific sign within the sign family.

A The letter designates a specific sign configuration, version and/or layout for graphics.

SIGNAGE KEYNOTES ?

AREA OF NO WORK, FACILITY TO REMAIN OPERATIONAL

KEY PLAN

A

B

C

D

E

F F

G G

F.1 F.1

H H

I I

J J

K K

L L

M M

5 6 6.1 7

14 15 16 17 18 19

H.5

I.4

J.7

IN-05.07

IN-09.03

CLEAN

UTLITY

10951095

CLEAN

SUPPLY

10931093

EXAM 8

10891089

TLT/SHWR

10871087

CHAIR

EXAM

1085b1085b

EXAM 6

10831083

TRIAGE

10841084

TEAM

AREA

1086A1086A

TEAM

AREA

1101A1101A

HAC

11051105

MENTAL

HEALTH

1099A1099A

CORRIDOR

OC21OC21

ALCOVE

10881088

EXAM 5

BARIATRIC/

WOMENS

HEALTH

1100A1100A

BARIATRIC/

WOMENS

HEALTH

TLT

1100B1100B

AMBULANCE

BAY

10981098

CORRIDOR

OC20OC20

STAFF

TOILET

10961096

OFFICE

10941094

OFFICE

10971097

STAFF

LOUNGE

11021102

TLT

MENTAL

HEALTH

1099B1099B

IN-69.1

IN-05.07

IN-69.1

IN-69.1

SOILED

UTILITY

10921092

EXAM 2 -

NEGATIVE

PRESS

1104A1104A

TLT

1108C1108C

ANTE

ROOM

1108A1108A

EXAM 1-

NEGATIVE

PRESS

1108B1108B

RECEPTION

1080C1080C

WAITING

10821082

EXAM 4

11031103

MEDS

11061106

CONF

10251025

CONSULT

ROOM 2

10281028

CONSULT

ROOM 1

10261026

NURSE

MANAGER

OFFICE

10241024

LOGISTICS

STORAGE

10231023

CLEAN

UTILITY

10211021

EXAM 7

10221022

STAFF

TLT

1019B1019B

EXAM 2

10191019 SOILED

UTILITY /

SPD

10161016

EXAM 1

10171017

PATIENT

TLT

10331033

EQ.

ALCOVE

10311031

TEAM

WORK

STATIONS

10151015

EXAM 13 /

CONSULT

RM 3

10111011

EXAM 12

10051005

EXAM 11

10031003

TELEHEALTH

10011001

TELEHEALTH

10021002

EXAM 10

10041004

EXAM 9

10171017

EXAM 8

11981198

STOR

10001000

HALLWAY

OC14OC14

WAITING

1032B1032B

FAMILY

TLT

10341034

LACTATION

10361036

MECH

10321032

RECEPT

CHECK

IN/OUT

1032A1032A

MEDS

10141014

WEIGH

AREA

10121012

IN-69.1

IN-05.07

IN-05.07

IN-69.1

IN-05.07

IN-05.07

IN-09.03

IN-69.1

IN-09.03

IN-69.1

IN-39.1

IN-05.07

IN-05.07

IN-05.07

IN-69.1

IN-05.07

IN-69.1

IN-69.1

IN-05.07

IN-05.07

IN-69.1

IN-09.03

IN-69.1

IN-05.07

IN-69.1

IN-69.1

IN-05.07

IN-69.1

IN-05.07

IN-69.1

IN-05.07

IN-05.07

IN-09.03

IN-39.1

IN-39.1

IN-09.03

IN-01.10

IN-01.10

IN-05.07

IN-39.1

IN-09.03

IN-09.03

IN-01.05

IN-69.1

IN-01.05

IN-69.1

IN-09.03

IN-05.07

IN-05.07

IN-01.01.03

IN-01.01.03

IN-13.01

IN-13.01

IN-69.1

IN-05.07

IN-05.07

IN-09.03

IN-13.01

IN-39.1

IN-01.31

IN-01.31

IN-01.31

IN-01.31

IN-01.31

IN-01.05

IN-69.1

IT

1051B1051B

ELECT

1051A1051A

IN-05.07

IN-13.01

IN-11.01

IN-11.01

IN-01.03

IN-01.03

IN-69.1

IN-09.08

IN-69.1

91 11

A

B

A

C

B

B

A

OC20

1099A

1099B 11

B

1102A

1080C

B

B

1001 1002

1003 1004

1015A

1033 S9B

1017 1016

1022B

1019B

O C

TLT

1022B1022B

TLT

1104B1104B

IN-01.30

IN-01.30

IN-01.05

IN-01.05

IN-01.30

I.5 I.5

N

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

AREA A

B400 KEY PLAN

AREA B

AREA

A1

C&S Engineers, Inc.

2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com

Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: 612-249-5600 www.obernel.com

Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com

B

IM

/6

-3

B

E x p a n d

R e lo c a te

U rg e n t C a re

A n d

R e n o v a te s t F lo o r

P a ti e n t C a re

/6

-3

.B

.A

.r v t

/1

/2

:5

:1

A

M

AW101

B400 - LEVEL 1 - SIGNAGE PLAN

TRIPLE C - THE A&E GROUP

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

676-19-327

05/20/2021 M. PERKINS K.

MCDERMOTT

ISSUED FOR

CONSTRUCTION

Expand and Renovate B400 for Urgent and Primary Care

500 E Veterans St, Tomah, WI 54660

1 VERIFY RECEPTION SIGNAGE NEEDS WITH OWNER.

2 FURNITURE IS NOT IN CONTRACT

3 ADDITIONAL URGENT CARE SIGNAGE TO BE DETERMINED BY OWNER

4 SIGN MOUNT TO BE LIGATURE FREE

1/8" = 1'-0" F1

B400 LEVEL 1 - SIGNAGE PLAN

1. REFER TO PLAN SHEETS FOR SIGNAGE LOCATION INFORMATION, REFER

TO SPECIFICATIONS FOR ADDITIONAL SIGNAGE, IDENTIFICATION AND

SYSTEMS / EQUIPMENT LABELING REQUIREMENTS.

2. REFER TO AW100 FOR SIGNAGE MESSAGE AND SCHEDULE

INFORMATION.

3. REFER TO AW100 FOR DETAILS AND SIGNAGE MOUNTING.

4. REFER TO "IN" SERIES SHEETS FOR ARCHITECTURAL INTERIOR FINISHES

AND PAINTS.

SIGN TYPE, SEE SCHEDULEXXX

MANDATORY POLICY SIGN DESIGNATIONS

IN-02.03 A

I Designates an interior sign.

N Identifies the sign is non-illuminated.

02 Two digit number identifies a particular sign type family .

.03 The two digit number, following the period, identifies a specific sign within the sign family.

A The letter designates a specific sign configuration, version and/or layout for graphics.

SIGNAGE KEYNOTES ?

AREA OF NO WORK, FACILITY TO REMAIN OPERATIONAL

KEY PLAN

1 2

F F

G G

F.1

H H

I

J

K K

L L

M M

3 4 5

H.5 H.5

J.7 J.7

MECH

20132013

INFUSION

ROOM

20152015

CORRIDOR

OC22OC22

MECH

20172017

EXAM 1

20192019

EXAM 2

20212021

EXAM 4

20222022

EXAM 5

20202020

SOILED

UTILITY

20242024

CLEAN

UTILITY -

LOGISTICS

20232023

EXAM 3

20252025

MED

EQUIPMENT

STORAGE

20272027

TEAM

WORK

AREA

20302030

TLT

20282028

CLEAN

LINENS

20262026

IN-39.1

IN-05.07

IN-05.07

IN-05.07

IN-05.07

IN-69.1

IN-05.07

IN-69.1

IN-69.1

IN-69.1

IN-09.03

IN-69.1

IN-05.07

IN-01.10

IN-01.01.03

IN-39.1

IN-39.1

IN-01.31

SOILED

UTILITY

101 SF

IN-69.1

2019 2020

2021 2022

2027 2028

IN-01.05

IN-15.51C

I.5 I.5

TELE

76 SF

N

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

B400 KEY PLAN

AREA C

C&S Engineers, Inc.

2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com

Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: 612-249-5600 www.obernel.com

Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com

B

IM

/6

-3

B

E x p a n d

R e lo c a te

U rg e n t C a re

A n d

R e n o v a te s t F lo o r

P a ti e n t C a re

/6

-3

.B

.A

.r v t

/1

/2

:5

:2

A

M

AW102

B400 - LEVEL 2 - SIGNAGE PLAN

TRIPLE C - THE A&E GROUP

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

676-19-327

05/20/2021 M.PERKINS ENN

ISSUED FOR

CONSTRUCTION

Expand and Renovate B400 for Urgent and Primary Care

500 E Veterans St, Tomah, WI 54660

1/8" = 1'-0" F1

B400 LEVEL 2 - SIGNAGE PLAN

1 FURNITURE IS NOT IN CONTRACT

1. REFER TO PLAN SHEETS FOR SIGNAGE LOCATION INFORMATION, REFER

TO SPECIFICATIONS FOR ADDITIONAL SIGNAGE, IDENTIFICATION AND

SYSTEMS / EQUIPMENT LABELING REQUIREMENTS.

2. REFER TO AW100 FOR SIGNAGE MESSAGE AND SCHEDULE

INFORMATION.

3. REFER TO AW100 FOR DETAILS AND SIGNAGE MOUNTING.

4. REFER TO "IN" SERIES SHEETS FOR ARCHITECTURAL INTERIOR FINISHES

AND PAINTS.

SIGN TYPE, SEE SCHEDULEXXX

MANDATORY POLICY SIGN DESIGNATIONS

IN-02.03 A

I Designates an interior sign.

N Identifies the sign is non-illuminated.

02 Two digit number identifies a particular sign type family .

.03 The two digit number, following the period, identifies a specific sign within the sign family.

A The letter designates a specific sign configuration, version and/or layout for graphics.

SIGNAGE KEYNOTES ?

AREA OF NO WORK, FACILITY TO REMAIN OPERATIONAL

KEY PLAN

407.A

407.B1

407.C1

407.D1

407.E

407.F

407.G1

407.H

407.I

407.J

407.K

407.L

407.M

407.N

407.14407.11 407.12.1407.12407.9407.7407.41407.4407.3407.21

J.39

J.40

J.41

407.H2

407.H1

407.13.1

OFFICE

3790A3790A

MECH /

ELECT

3790C3790C

OPEN

OFFICE

37903790

OFFICE

3790B3790B

RESTROOM

37883788

MECH /

ELEC

37803780

OPEN

OFFICE

37753775

OFFICE

3775B3775B

IN-09.02 IN-09.01

IN-69.1

IN-39.1

IN-69.1

IN-69.1

IN-69.1

IN-39.1

IN-69.1

IN-01.31

IN-01.31

IN-01.31

IN-69.1

DATA

CLOSET

3772A3772A

ELECTRICAL

37723772

IN-01.03

3790A 3790C

B

3790B

DEDUCT ALT 1: ELIMINATE

ALL WORK ASSOCIATED WITH

NORTH PORTION OF

BUILDING 407.

DEDUCT ALT 2:

ELIMINATE ALL WORK

ASSOCIATED WITH

SOUTH PORTION OF

BUILDING 407.

DEDUCT ALT 2:

ELIMINATE ALL WORK

ASSOCIATED WITH

SOUTH PORTION OF

BUILDING 407.

DEDUCT ALT 2:

ELIMINATE ALL WORK

ASSOCIATED WITH

SOUTH PORTION OF

BUILDING 407.

DEDUCT ALT 2:

ELIMINATE ALL WORK

ASSOCIATED WITH

SOUTH PORTION OF

BUILDING 407.

N

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

B407 KEY PLAN

AREA A

Expand and Renovate B400 for Urgent and Primary Care

C&S Engineers, Inc.

2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com

Obernel 1400 Van Buren St NE

UNIT 130,

Minneapolis, MN 55413 Phone: 612-249-5600 www.obernel.com

Hinman Cinsulting Enginers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com

B

IM

/6

-3

B

E x p a n d

R e lo c a te

U rg e n t C a re

A n d

R e n o v a te s t F lo o r

P a ti e n t C a re

/6

-3

.B

.A

.r v t

/1

/2

:5

:3

A

M

AW103

B407 - LEVEL 3 - SIGNAGE PLAN - DEDUCT ALT #1

& #2

TRIPLE C - THE A&E GROUP

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

676-19-327

05/20/2021 M. PERKINS K.

MCDERMOTT

ISSUED FOR

CONSTRUCTION

500 E Veterans St, Tomah, WI 54660

1/8" = 1'-0" F1

B407 LEVEL 3 - SIGNAGE PLAN

1 FURNITURE IS NOT IN CONTRACT

DEDUCT ALT 1: ELIMINATE ALL WORK ASSOCIATED

WITH NORTH PORTION OF BUILDING 407.

DEDUCT ALT 2: ELIMINATE ALL WORK ASSOCIATED

WITH SOUTH PORTION OF BUILDING 407.

GI000-COVER SHEET
GI001-PROJECT SHEET INDEX
GI050-GENERAL NOTES
GI101-B400 -LEVEL 1 -FIRE AND LIFE SAFETY PLAN & CODE DATA
GI102-B400 -LEVEL 2 -FIRE AND LIFE SAFETY PLAN & CODE DATA
GI104-B407 -LEVEL 3 -FIRE AND LIFE SAFETY PLAN & CODE DATA -DEDUCT ALT #1 & #2
GI201-INFECTION CONTROL PLAN & INTERIM LIFE
GC101-PROJECT PHASING
GC102-PHASING PLANS
H101-B400 -LEVEL 1 -HAZARDOUS MATERIAL ABATEMENT
H102-B400 -LEVEL 2 -HAZARDOUS MATERIAL ABATEMENT
H103-407-B407 -LEVEL 3 -HAZARDOUS MATERIAL ABATEMENT
HC101-B400 -LEVEL 1 -HAZARDOUS MATERIAL ABATEMENT -PIPING
VF100-CONTROL POINT SITE PLAN
VF101-viuvTiiig i iuvCIVIL SURVEY PLAN
CD101-CIVIL DEMOLITION PLAN
CS101-CIVIL SITE PLAN
COo-CIVIL SITE PLAN STAGING AREA
CG101-CIVIL GRADING PLAN
CG501-CIVIL DETAIL SHEET 1
CG502-CIVIL DETAIL SHEET 2
CU101-CIVIL UTILITY PLAN
SJ001-GENERAL STRUCTURAL NOTES
SJ002-GENERAL STRUCTURAL NOTES CONTINUED
SJ003-SPECIAL INSPECTIONS
SB100-B400 -LEVEL 1 -FOUNDATION PLAN -OVERALL
SB101-B400 -LEVEL 1 - FOUNDATION PLAN -AREA A
SF102-B400 -LEVEL 2 - FRAMING PLAN -OVERALL
SF103-B400 -LEVEL 2 -ROOF FRAMING PLAN -AREA A
SF201-FRAMING ELEVATIONS
SF202-FRAMING ELEVATIONS
SF203-FRAMING ELEVATIONS
SF501-TYPICAL DETAILS
SF502-TYPICAL DETAILS
SF503-TYPICAL DETAILS
SF504-TYPICAL DETAILS
SF505-TYPICAL DETAILS
SB510-FOUNDATION DETAILS
SF520-FRAMING DETAILS
SF521-FRAMING DETAILS
SF530-COLD-FORMED STEEL FRAMING
SF601-GRAPHICAL COLUMN SCHEDULE
AE000-SYMBOLS, & GENERAL NOTES
AS101-ARCHITECTURAL SITE PLAN
AG100-FLOOR PLAN -LEVEL 1, URGENT CARE CENTER PROGRAM PLAN
AG103-FLOOR PLAN -LEVEL 1, CLINICAL SPACE PROGRAM PLAN
AG200-FLOOR PLAN -LEVEL 2, SPECIALTY CARE PROGRAM PLAN
AG201A-FLOOR PLAN -LEVEL 3 -SWING SPACE LAYOUT B407-DEDUCT ALT #1 & #2
AD101-B400 -LEVEL 1 -DEMOLITION PLAN
AD102-B400 -LEVEL 2 -DEMOLITION PLAN
AD103-407-B407 -LEVEL 3 -DEMOLITION PLAN -DEDUCT AL #1 & #2
AD121-B400 -LEVEL 1 -DEMOLITION RCP
AD122-B400 -LEVEL 2 -DEMOLITION RCP
AD123-407-B407 -LEVEL 3 -DEMOLITION RCP -DEDUCT ALT #1 & #2
AE101-B400 -LEVEL 1 -FLOOR PLAN -OVERALL
AE102-B400 -LEVEL 2 -FLOOR PLAN -OVERALL
AE103-407-B407 -LEVEL 3 -FLOOR PLAN -DEDUCT ALT #1& #2
AE104-B400 -ROOF PLAN -OVERALL
AC101-B400 -LEVEL 1 -REFLECTED CEILING PLAN
AC102-B400 -LEVEL 2 -REFLECTED CEILING PLAN
AC103-407-B407 -LEVEL 3 -REFLECTED CEILING PLAN -DEDUCT ALT #1 & #2
AE201-B400 EXTERIOR ELEVATIONS
AE201-407-B407 EXTERIOR ELEVATIONS -DEDUCT ALT #1 & #2
AE202-B400 EXTERIOR ELEVATIONS
AE301-BUILDING SECTIONS
AE320-WALL SECTIONS
AE321-WALL SECTIONS
AE322-WALL SECTIONS
AE401-B400 -LEVEL 1 -ENLARGED FLOOR PLANS
AE401A-B400 -LEVEL 1 -ENLARGED FLOOR PLANS
AE401B-B400 -LEVEL 1 -ENLARGED FLOOR PLANS
AE401C-B400 -LEVEL 1 -ENLARGED FLOOR PLANS
AE401D-B400 -LEVEL 1 -ENLARGED FLOOR PLANS
AE402-B400 -LEVEL 2 -ENLARGED FLOOR PLANS
AE500-EXTERIOR WALL AND ROOF ASSEMBLIES
AE520-EXTERIOR SECTION DETAILS
AE521-EXTERIOR SECTION DETAILS
AE551-DETAILS -INTERIOR
AE552-DETAILS -INTERIOR
AE560-DOOR DETAILS
AE561-DOOR AND LOUVER DETAILS
AE601-DOOR WINDOW & LOUVER SCHEDULES
AE710-ARCHITECTURAL DOOR, WINDOW & FRAME TYPES
AE720-STANDARD PARTITION TYPES
AE721-PARTITION HEAD DETAILS
AE722-PARTITION FRAMING DETAILS
AE730-TYPICAL MOUNTING HEIGHTS
AG900-B400 RENDERINGS
AG901-B400 RENDERINGS
AG902-B400/ B407 RENDERINGS
AW001-SIGNAGE ABBREVIATIONS, SYMBOLS, GENERAL NOTES & DETAILS
AW101-B400 -LEVEL 1 -SIGNAGE PLAN
AW102-B400 -LEVEL 2 -SIGNAGE PLAN
AW103-B407 -LEVEL 3 -SIGNAGE PLAN -DEDUCT ALT #1 & #2
IN001-NTERIOR FINISH ABBREVIATIONS, SYMBOLS, GENERAL NOTES & FINISH BOARDS
IN101-B400 -LEVEL 1 -INTERIOR FINISH PLAN -OVERALL
IN101A-B400 -LEVEL 1 -INTERIOR FINISH PLANS -AREA & A1
IN101B-B400 -LEVEL 1 -INTERIOR FINISH PLANS -AREA
IN102C-B400 -LEVEL 2 -INTERIOR FINISH PLANS -AREA C
IN103D-B407 -LEVEL 3 -INTERIOR FINISH PLANS -AREA A, B & C -DEDUCT ALT #1& #2
IN501-INTERIOR FINISH DETAILS
IN601-INTERIOR FINISH LEGEND AND SCHEDULES
IF101AB-B400 -LEVEL 1 -INTERIOR FURNITURE PLAN -FOR REFERENCE ONLY
IF102C-B400 -LEVEL 2 -INTERIOR FURNITURE PLAN -FOR REFERENE ONLY
IF103D-B407 -LEVEL 3 -INTERIOR FURNITURE PLAN -FOR REFERENCE ONLY -DEDUCT ALT #1 & #2
IF104-FURNITURE PLAN -FOR REFERENCE ONLY
IF105-FURNITURE PLAN -FOR REFERENCE ONLY
IF106-FURNITURE PLAN -FOR REFERENCE ONLY
Q001-EQUIPMENT SCHEDULE
Q101AB-B400 -LEVEL 1 -EQUIPMENT PLANS
Q101C-B400 -LEVEL 2 -EQUIPMENT PLAN
F000-FIRE PROTECTION ABBREVIATIONS AND SYMBOLS
FD101-B400 -LEVEL 1 - FIRE PROTECTION DEMOLITION PLAN
FD102-B400 -LEVEL 2 - FIRE PROTECTION DEMOLITION PLAN
FD103-407-B407 -LEVEL 3 - FIRE PROTECTION DEMOLITION PLAN
FP101-B400 -LEVEL 1 - FIRE PROTECTION PLAN
FP102-B400 -LEVEL 2 - FIRE PROTECTION PLAN
FP103-407-B407 -LEVEL 3 - FIRE PROTECTION PLAN
P-000-PLUMBING ABBREVIATIONS AND SYMBOLS
PD100-B400 -FOUNDATION -PLUMBING DEMOLITION PLAN
PD101-B400 -LEVEL 1 -PLUMBING DEMOLITION PLAN
PD102-B400 -LEVEL 2 -PLUMBING DEMOLITION PLAN
PD201-B400 -LEVEL 1 -MED GAS DEMOLITION PLAN
P-100-B400 -FOUNDATION -PLUMBING PLAN
P-101-B400 -LEVEL 1 -PLUMBING PLAN
P-102-B400 -LEVEL 2 -PLUMBING PLAN
P103-407-B407 -LEVEL 3 -PLUMBING PLAN
P-201-B400 -LEVEL 1 -MED GAS PLAN
P-300-B400 -PLUMBING ENLARGED PLANS
P-301-B400 -PLUMBING ENLARGED PLANS
P-302-B400 -PLUMBING ENLARGED PLANS
P-303-B400 -PLUMBING ENLARGED PLANS
P-304-B400 -PLUMBING ENLARGED PLANS
P-305-B400 -PLUMBING ENLARGED PLANS
P-400-PLUMBING RISERS
P-401-PLUMBING RISERS
P-402-PLUMBING RISERS
P-403-PLUMBING RISERS
P-404-PLUMBING RISERS
P-500-PLUMBING DETAILS
P-700-PLUMBING SCHEDULES
M-000-MECHANICAL ABBREVIATIONS AND SYMBOLS
MD101-B400 -LEVEL 1 -HVAC DEMOLITION PLAN
MD101A-B400 -LEVEL 1 -HVAC DEMO PLAN -DEDUCT ALT. #4
MD102-B400 -LEVEL 2 -HVAC DEMOLITION PLAN
MD103-407-B407 -LEVEL 3 -HVAC DEMOLITION PLAN
MD200-B400 -FOUNDATION -HVAC PIPING DEMOLITION PLAN
MD201-B400 -LEVEL 1 -HVAC PIPING DEMOLITION PLAN
MD202-B400 -LEVEL 2 -HVAC PIPING DEMOLITION PLAN
M-100-B400 -LEVEL 1 -HVAC TEMPORARY PLAN
M-101-B400 -LEVEL 1 - HVAC PLAN
M-101A-B400 -LEVEL 1 - HVAC PLAN -DEDUCT ALT. #4
M-102-B400 -LEVEL 2 - HVAC PLAN
M-103-407-B407 -LEVEL 3 - HVAC PLAN
MP200-B400 -FOUNDATION -HVAC PIPING PLAN
MP201-B400 -LEVEL 1 -HVAC PIPING PLAN
MP202-B400 -LEVEL 2 -HVAC PIPING PLAN
MP203-407-B407 -LEVEL 3 -HVAC PIPING PLAN
M-400-ENLARGED MECHANICAL PLANS
M-401-ENLARGED MECHANICAL PLANS
M-402-ENLARGED MECHANICAL PLANS -DEDUCT ALT. #4
M-500-MECHANICAL DETAILS
M-501-MECHANICAL DETAILS
M-502-MECHANICAL DETAILS
M-600-MECHANICAL SECTIONS
M-700-MECHANICAL SCHEDULES
M-800-MECHANICAL CONTROLS
M-801-MECHANICAL CONTROLS
M-802-MECHANICAL CONTROLS
E-000-ELECTRICAL ABBREVIATIONS AND SYMBOLS
ED101-B400 -LEVEL 1 - ELECTRICAL DEMOLITION PLAN
ED102-B400 -LEVEL 2 - ELECTRICAL DEMOLITION PLAN
ED103-407-B407 -LEVEL 3 - ELECTRICAL DEMOLITION PLAN
EL101-B400 -LEVEL 1 - LIGHTING PLAN
EL102-B400 -LEVEL 2 - LIGHTING PLAN
EL103-407-B407 -LEVEL 3 - LIGHTING PLAN
EL111-B400 -LEVEL 1 -LIGHTING CALCS
EL112-B400 -LEVEL 2 -LIGHTING CALCS
EL113-407-B407 -LEVEL 3 -LIGHTING CALCS
EP101-B400 -LEVEL 1 - POWER PLAN
EP102-B400 -LEVEL 2 - POWER PLAN
EP103-407-B407 -LEVEL 3 - POWER PLAN
EY101-B400 -LEVEL 1 - SPECIAL SYSTEMS PLAN
EY102-B400 -LEVEL 2 - SPECIAL SYSTEMS PLAN
EY103-407-B407 -LEVEL 3 - SPECIAL SYSTEMS PLAN
E-501-ELECTRICAL DETAILS
E-601-B400 ELECTRICAL DIAGRAMS
E-602-B400 ELECTRICAL DIAGRAMS
E-700-ELECTRICAL SCHEDULES
EF101-B400 -LEVEL 1 - FIRE ALARM DEMOLITION PLAN
EF102-B400 -LEVEL 2 - FIRE ALARM DEMOLITION PLAN
EF103-407-B407 -LEVEL 3 - FIRE ALARM DEMOLITION PLAN
EF201-B400 -LEVEL 1 - FIRE ALARM PLAN
EF202-B400 -LEVEL 2 - FIRE ALARM PLAN
EF203-407-B407 -LEVEL 3 - FIRE ALARM PLAN

File details come from the government source that posted it. Updated .