ATTACHMENT 15 - Fire Alarm.pdf
PDF 6 MB Posted
- Solicitation number
- 36C77621B0009
About this file
This solicitation is for a construction project to expand and renovate an existing building (B400) to support urgent and primary care services at the Department of Veterans Affairs Medical Center in Tomah, Wisconsin. The contractor shall complete all demolition and removal of existing structures, and furnish labor, materials, and work required by the attached drawings and specifications. The project includes expanding clinical space on the first floor for urgent care and renovating specialty care areas on the second floor. The contractor must prepare the site for building operations, including demolition. The solicitation was issued by the Department of Veterans Affairs Technology Acquisition Center in Austin, Texas.
View the file
Other files
Show all 29
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S
S
S
SD
F
F
F
SD
SD
SD
SD
SD
SD
SD
S
A
S
SD
SF
SD
S
SD
S
S
S
SD
S
S
SD
S
S
S
S FSD
1 2 3 4 5 6 6.1 7 7.8 8 9 9.1 9.9 10 11 11.2 12 13 14 18171615
M.3
M
L
K.3
K
J.4
J.3
J
I.5
I.2
I
H.1
H
G
F.1
F
E
D
C
B
A
EX CP-6-1EX NP-1-1
EX LS-2-1
EX FA
EXISTING FIRE ALARM
WIRING CABINETS
EX FACU
EX CP 6-1
EX ECB-LS
EX ECB-CR
EX ECB-EQ EX REMOTE
GENERATOR PANEL
EX LOAD CENTER
EX NP-3-1
EX CP-4-1
EX NP-2-1
EX CP-2-1
EX CP-3-1
EX ELEVATOR
PANEL
EX NVP-1EX MDP(480)
EX DP-208-EQ
EX MSB(208)
EX ATS-LS
EX ATS(480)CR
EX DP-LS
EX ATS(208)CR
EX DP-CR(480)
EX DP-LQ
EX DP-CR(208)
EX T-CR
EX T-EQ
EX ATS-EQ
EX LS-1-1
EX CP-1-1
A. EXISTING CONDITION DRAWINGS INDICATE CONDITIONS AS THEY WERE
PLANNED FOR UNDER PREVIOUS PROJECTS, AND ARE INCLUDED FOR
REFERENCE ONLY. NOT ALL EXISTING DEVICES/ITEMS MAY BE SHOWN AND
ACTUAL CONDITIONS MAY VARY FROM THE PLANNED CONDITIONS. PROVIDE
DETAILED EVALUATION OF BUILDING SYSTEMS PRIOR TO CONSTRUCTION
AND REPORT DISCREPANCIES AND DEFICIENCIES TO ENGINEER. SYSTEMS
SHALL BE IN SIMILAR OR BETTER CONDITIONS AFTER COMPLETION OF
WORK.
B. FIELD VERIFY EXACT CONDITIONS PRIOR TO ANY DEMOLITION AND
MAINTAIN CONTINUITY OF ADJACENT CIRCUITS THAT REMAIN. REPORT ANY
DISCREPANCIES TO THE ENGINEER.
C. DISCONNECT AND REMOVE ELECTRICAL DEVICES NOTED AND/OR ON
WALLS THAT ARE BEING DEMOLISHED. REMOVE WIRING, CONDUIT,
SUPPORTS, ACCESSORIES, ETC BACK TO SOURCE. LABEL CIRCUIT
BREAKERS MADE UNUSED DURING DEMOLITION AS SPARE. REFER TO
ARCHITECTURAL PLANS FOR WALLS THAT ARE TO BE DEMOLISHED. WALLS
BEING REMOVED ARE SHOWN DASHED.
D. WHERE CIRCUITS TO REMAIN ARE INTERRUPTED DUE TO DEMOLITION,
CONTINUE THE CIRCUITS BY PROVIDING A J-BOX ABOVE CONCEALED
ACCESSIBLE CEILING, OR RE-FEED FROM AVAILABLE SOURCE.
E. ELECTRICAL DEVICES THAT HAVE BEEN INDICATED TO BE DISCONNECTED
AND REMOVED SHALL BE OFFERED TO THE OWNER AS SALVAGE UNLESS
INDICATED OTHERWISE. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR
DISPOSAL OF UNDESIRED ITEMS.
F. REFEED EXISTING CIRCUITS IN CONSTRUCTION LIMITS THAT CONFLICT
WITH NEW WORK. PROVIDE J-BOXES, CONDUIT, WIRING, AND OTHER
ACCESSORIES TO MAINTAIN INTEGRITY OF ELECTRICAL ITEMS. PROPERLY
SUPPORT ELECTRICAL ITEMS TO REMAIN IN CONSTRUCTION LIMITS.
PROVIDE REQUIRED COMPONENTS FOR PROPER INSTALLATION.
G. COORDINATE DEMOLITION WORK AS TO NOT REMOVE DEVICES/SYSTEMS
THAT ARE TO REMAIN AS EXISTING.
H. COORDINATE SYSTEM OUTAGES WITH OWNER.
I. MAINTAIN FIRE RATINGS WHERE CONDUITS ARE TO BE REMOVED FROM A
FIRE RATED STRUCTURE.
J. WHERE CEILINGS ARE REMOVED AND REPLACED; TEMPORARILY AND
PROPERLY SUPPORT ELECTRICAL DEVICES TO REMAIN.
K. PATCH AND RESTORE FINISHES WHERE DISTURBED OR DAMAGED DUE TO
ELECTRICAL DEMOLITION. REPAINT TO MATCH EXISTING WHERE
ELECTRICAL DEVICES ARE REMOVED.
L. PROVIDE STAINLESS STEEL BLANK COVER PLATES FOR ABANDONED
BOXES IN WALLS TO REMAIN.
M. COORDINATE DEMOLITION AND NEW WORK AS TO NOT REMOVE SYSTEMS,
DEVICES, AND/OR ACCESSORIES NECESSARY FOR AREAS IN LATER
PHASES.
N. FIRE ALARM SCOPE: REMOVE EXISTING FIRE ALARM DEVICES, WIRING, AND
RACEWAYS IN THE PROJECT AREAS IN THEIR ENTIRETY. PROVIDE NEW
DEVICES, WIRING, AND RACEWAYS AS INDICATED. MODIFY/EXPAND
EXISTING SILENT KNIGHT FACU AND ASSOCIATED EQUIPMENT PANELS TO
MEET NEW SYSTEM DESIGN.
EXAM
1027 EXAM
EXAM
OFFICE
OFFICE
OFFICE
OFFICE
EXAM
OFFICE
OFFICE
DIRTY UTILTIY
OFFICE
WAITING
NURSE STATION
OFFICE
EXAM
CONFERENCE
EXAM
EXAM
EXAM
OFFICE
OFFICE
WOMEN
VISITOR
TOILET
TLT
MECH
IT
1005 OFFICE
OFFICE
OFFICE
EXAM
STAIR
WAITING / CIRCULATION
EXAM
EXAM
EXAM
NURSE STATION
1085 EXAM
EXAM
WOMEN TLT
EXAM
EXAM
OFFICE
STORAGE
1096A
STAFF TOILET
STAFF TOILET
AMBULANCE GARAGE
IT
1051B
ELECT
1051A
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMP
321 4 5 6 7 8 9 10
GENERAL NOTES
KEY PLAN
KEYNOTES
AREA A
B400 KEY PLAN
AREA B
AREA
A1
AREA C
ARCHITECT/ENGINEER OF RECORD
A/E:
CONSULTANT
C&S Engineers, Inc.
2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com
Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com
Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com
B
IM
/6
-3
B
E x p a n d
R e lo c a te
U rg e n t
C a re A n d
R e n o v a te s t F lo o r P a ti e n t C a re
/6
-3
.4
.M
E P
.r v t
/1
/2
:4
:4
A
M
EF101
B400 - LEVEL 1 - FIRE ALARM
DEMOLITION PLAN
Expand and Renovate B400 for
Urgent and Primary Care
500 E Veterans St, Tomah, WI 54660
676-19-327
400/407
05/20/2021 A.BARTSCH T.INGLE
TRIPLE C - THE A&E GROUP
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
ISSUED FOR
CONSTRUCTION
SCALE: 1/8" = 1'-0"
B400 LEVEL 1 FLOOR PLAN - FIRE ALARM DEMOLITION
1 EXISTING REMOTE FIRE ALARM ANNUNCIATOR PANEL
SHALL BE DISCONNECTED AND STORED DURING
DEMOLITION TO BE REINSTALLED IN SIMILAR
LOCATION.
2 REMOVE AND RELOCATE EXISTING FIRE ALARM
MODULE PANEL.
3 EXISTING MAIN FIRE ALARM CONTROL UNIT - SILENT
KNIGHT IFP-2000ECS.
Revisions: Date:
ARCHITECT/ENGINEER OF RECORD
A/E:
CONSULTANT
C&S Engineers, Inc.
2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com
Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com
Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com
TRIPLE C - THE A&E GROUP
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
48553 5/20/2021 Anthony R. Nelson
Checked
A.NELSON
H
H
S F
SD
SD
S
1 2 3 4 5 6 6.1 7 7.8 8 9 9.1 9.9 10 11 11.2 12 13 14 18171615
M.3
M
L
K.3
K
J.4
J.3
J
I.5
I.2
I
H.1
H
G
F.1
F
E
D
C
B
A
EX NP-1-2
EX CP-6-2.1
EX CP-6-2
EX 4 CP-2-2
EX CP-2-2 EX CP-1-2
EX LS1-2
TEMPORARY
2007A
SOILED UTILITY
A. EXISTING CONDITION DRAWINGS INDICATE CONDITIONS AS THEY WERE
PLANNED FOR UNDER PREVIOUS PROJECTS, AND ARE INCLUDED FOR
REFERENCE ONLY. NOT ALL EXISTING DEVICES/ITEMS MAY BE SHOWN AND
ACTUAL CONDITIONS MAY VARY FROM THE PLANNED CONDITIONS. PROVIDE
DETAILED EVALUATION OF BUILDING SYSTEMS PRIOR TO CONSTRUCTION
AND REPORT DISCREPANCIES AND DEFICIENCIES TO ENGINEER. SYSTEMS
SHALL BE IN SIMILAR OR BETTER CONDITIONS AFTER COMPLETION OF
WORK.
B. FIELD VERIFY EXACT CONDITIONS PRIOR TO ANY DEMOLITION AND
MAINTAIN CONTINUITY OF ADJACENT CIRCUITS THAT REMAIN. REPORT ANY
DISCREPANCIES TO THE ENGINEER.
C. DISCONNECT AND REMOVE ELECTRICAL DEVICES NOTED AND/OR ON
WALLS THAT ARE BEING DEMOLISHED. REMOVE WIRING, CONDUIT,
SUPPORTS, ACCESSORIES, ETC BACK TO SOURCE. LABEL CIRCUIT
BREAKERS MADE UNUSED DURING DEMOLITION AS SPARE. REFER TO
ARCHITECTURAL PLANS FOR WALLS THAT ARE TO BE DEMOLISHED. WALLS
BEING REMOVED ARE SHOWN DASHED.
D. WHERE CIRCUITS TO REMAIN ARE INTERRUPTED DUE TO DEMOLITION,
CONTINUE THE CIRCUITS BY PROVIDING A J-BOX ABOVE CONCEALED
ACCESSIBLE CEILING, OR RE-FEED FROM AVAILABLE SOURCE.
E. ELECTRICAL DEVICES THAT HAVE BEEN INDICATED TO BE DISCONNECTED
AND REMOVED SHALL BE OFFERED TO THE OWNER AS SALVAGE UNLESS
INDICATED OTHERWISE. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR
DISPOSAL OF UNDESIRED ITEMS.
F. REFEED EXISTING CIRCUITS IN CONSTRUCTION LIMITS THAT CONFLICT
WITH NEW WORK. PROVIDE J-BOXES, CONDUIT, WIRING, AND OTHER
ACCESSORIES TO MAINTAIN INTEGRITY OF ELECTRICAL ITEMS. PROPERLY
SUPPORT ELECTRICAL ITEMS TO REMAIN IN CONSTRUCTION LIMITS.
PROVIDE REQUIRED COMPONENTS FOR PROPER INSTALLATION.
G. COORDINATE DEMOLITION WORK AS TO NOT REMOVE DEVICES/SYSTEMS
THAT ARE TO REMAIN AS EXISTING.
H. COORDINATE SYSTEM OUTAGES WITH OWNER.
I. MAINTAIN FIRE RATINGS WHERE CONDUITS ARE TO BE REMOVED FROM A
FIRE RATED STRUCTURE.
J. WHERE CEILINGS ARE REMOVED AND REPLACED; TEMPORARILY AND
PROPERLY SUPPORT ELECTRICAL DEVICES TO REMAIN.
K. PATCH AND RESTORE FINISHES WHERE DISTURBED OR DAMAGED DUE TO
ELECTRICAL DEMOLITION. REPAINT TO MATCH EXISTING WHERE
ELECTRICAL DEVICES ARE REMOVED.
L. PROVIDE STAINLESS STEEL BLANK COVER PLATES FOR ABANDONED
BOXES IN WALLS TO REMAIN.
M. COORDINATE DEMOLITION AND NEW WORK AS TO NOT REMOVE SYSTEMS,
DEVICES, AND/OR ACCESSORIES NECESSARY FOR AREAS IN LATER
PHASES.
N. FIRE ALARM SCOPE: REMOVE EXISTING FIRE ALARM DEVICES, WIRING, AND
RACEWAYS IN THE PROJECT AREAS IN THEIR ENTIRETY. PROVIDE NEW
DEVICES, WIRING, AND RACEWAYS AS INDICATED. MODIFY/EXPAND
EXISTING SILENT KNIGHT FACU AND ASSOCIATED EQUIPMENT PANELS TO
MEET NEW SYSTEM DESIGN.
OFFICE
UNOCCUPIED
CLEAN UTILITY
ELEC.
LAB
MECHANICAL
OFFICE
2015A
TOILET, STAFF
2030A
UTILITY ROOM, SOILED
TOILET
LOCKER ROOM
LAB
TREATMENT ROOM
EXAM/ TREATMENT ROOM
EXAM/ TREATMENT ROOM
TREATMENT ROOM
EXAM/TREATMENT ROOM
TREATMENT ROOM
STAIR
S9
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMP
321 4 5 6 7 8 9 10
GENERAL NOTES
KEY PLAN
KEYNOTES
AREA A
B400 KEY PLAN
AREA B
AREA
A1
AREA C
ARCHITECT/ENGINEER OF RECORD
A/E:
CONSULTANT
C&S Engineers, Inc.
2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com
Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com
Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com
B
IM
/6
-3
B
E x p a n d
R e lo c a te
U rg e n t
C a re A n d
R e n o v a te s t F lo o r P a ti e n t C a re
/6
-3
.4
.M
E P
.r v t
/1
/2
:4
:4
A
M
EF102
B400 - LEVEL 2 - FIRE ALARM
DEMOLITION PLAN
Expand and Renovate B400 for
Urgent and Primary Care
500 E Veterans St, Tomah, WI 54660
676-19-327
400/407
05/20/2021 A.BARTSCH T.INGLE
TRIPLE C - THE A&E GROUP
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
ISSUED FOR
CONSTRUCTION
SCALE: 1/8" = 1'-0"
B400 LEVEL 2 FLOOR PLAN - FIRE ALARM DEMOLITION
1 EXISTING FIRE ALARM POWER PANELS.
Revisions: Date:
ARCHITECT/ENGINEER OF RECORD
A/E:
CONSULTANT
C&S Engineers, Inc.
2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com
Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com
Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com
TRIPLE C - THE A&E GROUP
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
48553 5/20/2021 Anthony R. Nelson
SD
CO
S
S
J
H
SD SD
SD SD
S
SD
407.A
407.B1
407.C1
407.D1
407.E
407.F
407.G1
407.H
407.I
407.J
407.K
407.L
407.M
407.N
407.14407.11 407.12.1407.12
407.9407.7
407.41407.4407.3407.21
J.39
J.40
J.41
407.H2
407.H1
407.13.1
OPEN OFFICE
RESTROOM
MECH / ELEC
OPEN OFFICE
RESTROOM
EX CP3-3
EX CP1-3
EX LS1-3
EX NP1-3
DEDUCT ALT 1:
REMOVE WORK
ASSOCIATED WITH
B407 NORTH.
DEDUCT ALT 2:
REMOVE WORK
ASSOCIATED WITH
B407 SOUTH.
DEDUCT ALT 2:
REMOVE WORK
ASSOCIATED WITH
B407 SOUTH.
A. EXISTING CONDITION DRAWINGS INDICATE CONDITIONS AS THEY WERE
PLANNED FOR UNDER PREVIOUS PROJECTS, AND ARE INCLUDED FOR
REFERENCE ONLY. NOT ALL EXISTING DEVICES/ITEMS MAY BE SHOWN AND
ACTUAL CONDITIONS MAY VARY FROM THE PLANNED CONDITIONS. PROVIDE
DETAILED EVALUATION OF BUILDING SYSTEMS PRIOR TO CONSTRUCTION
AND REPORT DISCREPANCIES AND DEFICIENCIES TO ENGINEER. SYSTEMS
SHALL BE IN SIMILAR OR BETTER CONDITIONS AFTER COMPLETION OF
WORK.
B. FIELD VERIFY EXACT CONDITIONS PRIOR TO ANY DEMOLITION AND
MAINTAIN CONTINUITY OF ADJACENT CIRCUITS THAT REMAIN. REPORT ANY
DISCREPANCIES TO THE ENGINEER.
C. DISCONNECT AND REMOVE ELECTRICAL DEVICES NOTED AND/OR ON
WALLS THAT ARE BEING DEMOLISHED. REMOVE WIRING, CONDUIT,
SUPPORTS, ACCESSORIES, ETC BACK TO SOURCE. LABEL CIRCUIT
BREAKERS MADE UNUSED DURING DEMOLITION AS SPARE. REFER TO
ARCHITECTURAL PLANS FOR WALLS THAT ARE TO BE DEMOLISHED. WALLS
BEING REMOVED ARE SHOWN DASHED.
D. WHERE CIRCUITS TO REMAIN ARE INTERRUPTED DUE TO DEMOLITION,
CONTINUE THE CIRCUITS BY PROVIDING A J-BOX ABOVE CONCEALED
ACCESSIBLE CEILING, OR RE-FEED FROM AVAILABLE SOURCE.
E. ELECTRICAL DEVICES THAT HAVE BEEN INDICATED TO BE DISCONNECTED
AND REMOVED SHALL BE OFFERED TO THE OWNER AS SALVAGE UNLESS
INDICATED OTHERWISE. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR
DISPOSAL OF UNDESIRED ITEMS.
F. REFEED EXISTING CIRCUITS IN CONSTRUCTION LIMITS THAT CONFLICT
WITH NEW WORK. PROVIDE J-BOXES, CONDUIT, WIRING, AND OTHER
ACCESSORIES TO MAINTAIN INTEGRITY OF ELECTRICAL ITEMS. PROPERLY
SUPPORT ELECTRICAL ITEMS TO REMAIN IN CONSTRUCTION LIMITS.
PROVIDE REQUIRED COMPONENTS FOR PROPER INSTALLATION.
G. COORDINATE DEMOLITION WORK AS TO NOT REMOVE DEVICES/SYSTEMS
THAT ARE TO REMAIN AS EXISTING.
H. COORDINATE SYSTEM OUTAGES WITH OWNER.
I. MAINTAIN FIRE RATINGS WHERE CONDUITS ARE TO BE REMOVED FROM A
FIRE RATED STRUCTURE.
J. WHERE CEILINGS ARE REMOVED AND REPLACED; TEMPORARILY AND
PROPERLY SUPPORT ELECTRICAL DEVICES TO REMAIN.
K. PATCH AND RESTORE FINISHES WHERE DISTURBED OR DAMAGED DUE TO
ELECTRICAL DEMOLITION. REPAINT TO MATCH EXISTING WHERE
ELECTRICAL DEVICES ARE REMOVED.
L. PROVIDE STAINLESS STEEL BLANK COVER PLATES FOR ABANDONED
BOXES IN WALLS TO REMAIN.
M. COORDINATE DEMOLITION AND NEW WORK AS TO NOT REMOVE SYSTEMS,
DEVICES, AND/OR ACCESSORIES NECESSARY FOR AREAS IN LATER
PHASES.
N. FIRE ALARM SCOPE: REMOVE EXISTING FIRE ALARM DEVICES, WIRING, AND
RACEWAYS IN THE PROJECT AREAS IN THEIR ENTIRETY. PROVIDE NEW
DEVICES, WIRING, AND RACEWAYS AS INDICATED. MODIFY/EXPAND
EXISTING SILENT KNIGHT FACU AND ASSOCIATED EQUIPMENT PANELS TO
MEET NEW SYSTEM DESIGN.
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMP
321 4 5 6 7 8 9 10
GENERAL NOTES
KEYNOTES
B407 KEY PLAN
AREA A
KEY PLAN
ARCHITECT/ENGINEER OF RECORD
A/E:
CONSULTANT
C&S Engineers, Inc.
2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com
Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com
Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com
B
IM
/6
-3
B
E x p a n d
R e lo c a te
U rg e n t
C a re A n d
R e n o v a te s t F lo o r P a ti e n t C a re
/6
-3
.4
.M
E P
.r v t
/1
/2
:4
:5
A
M
EF103-407
B407 - LEVEL 3 - FIRE ALARM
DEMOLITION PLAN
Expand and Renovate B400 for
Urgent and Primary Care
500 E Veterans St, Tomah, WI 54660
676-19-327
400/407
05/20/2021 A.BARTSCH T.INGLE
TRIPLE C - THE A&E GROUP
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
ISSUED FOR
CONSTRUCTION
SCALE: 1/8" = 1'-0"
B407 LEVEL 3 FLOOR PLAN - FIRE ALARM DEMOLITION
1 EXISTING FIRE ALARM POWER PANELS.
Revisions: Date:
ARCHITECT/ENGINEER OF RECORD
A/E:
CONSULTANT
C&S Engineers, Inc.
2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com
Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com
Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com
TRIPLE C - THE A&E GROUP
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
48553 5/20/2021 Anthony R. Nelson
F
S
S
SD
S
S
S S
SD
S
S
S
S
S
S
S
SD
SD
S
S S
SD
S
S
S
S
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD SD
SD
SD
SD
SD
F
SD
A
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
SD
S
S
S
S
S
HD
SSSD
SD
SD
S
SD
S
S
F
SD
S
1 2 3 4 5 6 6.1 7 7.8 8 9 9.1 9.9 10 11 11.2 12 13 14 18171615
M.3
M
L
K.3
K
J.4
J.3
J
I.5
I.2
I
H.1
H
G
F.1
F
E
D
C
B
A
CONF
CONSULT ROOM 2
CONSULT ROOM 1
CLEAN UTILITY
EXAM 10
CHAIR EXAM
1085b
EXAM 6
ANTE ROOM
1108A
OFFICE
EXAM 8
ALCOVE
WHEELCHAIR ALCOVE
EQ. ALCOVE
EXAM 13 / CONSULT RM 3
EXAM 2
TEAM
WORK
STATIONS
WAITING
1032B
1101A
TEAM
AREA
1086A
TEAM
AREA
PATIENT TLT
TLT
1022B
STAFF TLT
1019B
MECH
STAFF TOILET
1100B
BARIATRIC/
WOMENS
HEALTH
TLT
1104B
TLT
TLT/SHWR
EXAM 2 - NEGATIVE PRESS
1104A
MEDS
EXAM 4
EXAM 5 BARIATRIC/ WOMENS HEALTH
1100A
1032A
RECEPT
CHECK
IN/OUT
WEIGH AREA
MEDS
CORRIDOR
OC11
EXAM 12
FAMILY TLT
NURSE MANAGER OFFICE
OFFICE
CLEAN SUPPLY
EXAM 7
SOILED UTILITY / SPD
CORRIDOR
OC13
EXAM 1
TLT
1108C
TELEHEALTH
TELEHEALTH
EXAM 9
HALLWAY
OC14
LOGISTICS STORAGE
WAITING
RECEPTION
1080C
EXAM 7
CLEAN UTLITY
SOILED UTILITY
CORRIDOR
OC20
1099A
MENTAL
HEALTH
STAFF LOUNGE
1108B
EXAM
1-
NEGATIVE
PRESS
VESTIBULE
TRIAGE
STOR
EXAM 8
EXAM 11
DPE
DPE
DPE
DPE
RTU-10S
RTU-10R
AHU-1
LACTATION
FA
EXISTING FIRE ALARM
WIRING CABINETS
EXISTING MAIN FIRE ALARM
CONTROL UNIT.
EX FACU
EX CP-6-1 EX NP-1-1
EX LS-2-1
EX CP-5-1
IT
1051B
ELECT
1051A
CLG
CLG
CLG
30,CLG
30,CLG
75,CLG
30,CLG
110,CLG
30,CLG
CLG
CLG
CLG
CLG
CLG
CLG
CLG
CLG
CLG
CLG
CLG
CLG
CLG
CLG
NP-1-1
CP-1-1
CLG
75,CLG
30,CLG
30,CLG
30,CLG
CLG
30,CLG
CLG
30,CLG
CLG
CLG
30,CLG
CLG
CLG
CLG
15,CLG
CLG
CLG
CLG
CP-8-1 NP-5-1
EX ECB-EQ
EX REMOTE
GENERATOR PANEL
EX ATS-LS
EX ATS(480)CR
EX ATS-EQEX DP-LS
EX ATS(208)CR EX DP-LQ
EX DP-CR(480)
EX T-CR
EX DP-CR(208)
EX DP-208-EQ
EX T-EQ
EX ECB-LS
EX ECB-CR
EX LOAD CENTER
EX NP-3-1
EX MSB(208)
EX CP-3-1
EX ELEVATOR
PANEL
EX NVP-1
EX MDP(480)
EX CP-2-1
EX NP-2-1
EX CP-4-1
30,CLG
15,CLG
FSD FSD
CP-1-1-1 CP-1-1-1
2 2
DPE
DPE
FSD
CP-1-1-1
DPE
DPE
CP-8-1-39
FSD
HAC
CLG
30,CLG
30,CLG
75,CLG
EX
EX
LS-1-1
AHU-1
EX NP-4-1
EX CP-7-1
75,CLG
CLG
FSD
CP-8-1-39
DPE2
A. ALIGN DEVICES VERTICALLY WHERE LIGHTING, POWER, SPECIAL SYSTEMS,
AND FIRE ALARM DEVICES WITH DIFFERENT MOUNTING HEIGHTS ARE
INDICATED CLOSE TO OTHER DEVICES.
B. REFER TO THE ARCHITECTURAL ELEVATION AND DETAIL DRAWINGS FOR
COORDINATION OF ELECTRICAL DEVICES.
C. CUTTING, DRILLING, AND/OR BORING THROUGH STRUCTURAL MEMBERS IS
NOT ACCEPTABLE.
D. PROVIDE FIRE RATED SEALS ON PENETRATIONS IN FIRE RATED FLOORS
AND WALLS. COORDINATE RATED LOCATIONS WITH LIFE SAFETY CODE
PLAN DRAWINGS.
E. PROVIDE INSULATED BUSHINGS FOR ROUGH-IN AND CONDUIT SLEEVE
LOCATIONS PRIOR TO INSTALLATION OF ANY CABLING.
F. BRANCH CIRCUITS CONDUCTOR LENGTHS FROM PANEL LONGER THAN 100’
FOR 120V AND 200' FOR 277V SHALL BE #10 OR LARGER FOR ENTIRE
LENGTH OF CIRCUIT FOR LINE, NEUTRAL, AND GROUND WIRES.
G. PROVIDE DEDICATED NEUTRAL FOR EACH MULTIWIRE BRANCH CIRCUIT
PHASE CONDUCTOR.
H. FOR DEVICE LOCATIONS SPECIFIED FOR ROUGH-IN, UNLESS NOTED
OTHERWISE, PROVIDE DOUBLE GANG J-BOX WITH SINGLE GANG MUD RING
AND BLANK COVER PLATE. ROUTE 1"C. UP INTO CONCEALED ACCESSIBLE
CEILING SPACE. PROVIDE BUSHINGS AND PULL STRING IN CONDUIT.
I. INSTALL SMOKE DETECTORS AT LEAST 3'-0” FROM ANY HVAC SUPPLY
DIFFUSER.
J. PROVIDE DUCT SMOKE DETECTORS FOR CONTROL OF SMOKE DAMPERS.
PROVIDE ONE CONTROL RELAY AND ONE ALARM INDICATOR FOR EACH
DETECTOR. PROVIDE 120V POWER AT EACH DAMPER LOCATION.
COORDINATE INSTALLATION WITH MECHANICAL CONTRACTOR. INSTALL
DETECTORS A MINIMUM OF 6 DUCT WIDTHS FROM ANY AIR INLET. PROVIDE
SAMPLING TUBE THAT EXTENDS INTO THE AIR STREAM, AND MOUNT
DETECTOR IN CENTER OF VERTICAL DIMENSION OF THE DUCT. DUCT
SMOKE DETECTORS INSTALLED FOR INDIVIDUAL CONTROL OF FIRE/SMOKE
DAMPERS SHALL BE INSTALLED A MAXIMUM OF 5' FROM THE DAMPER, WITH
NO AIR OUTLETS OR INLETS BETWEEN THE DETECTOR AND THE DAMPER.
K. SET EACH FIRE ALARM SYSTEM SPEAKER UNITS TO BEST SUIT INDIVIDUAL
ROOM CHARACTERISTICS AND TO ENSURE ALARM SOUND LEVELS OF 15db
OVER AMBIENT LEVELS. FIRE ALARM SPEAKER/STROBE AND STROBE ONLY
DEVICES SHALL BE WHITE.
L. PROVIDE CIRCUIT BREAKER 'LOCK-ON' FOR FIRE ALARM POWER CIRCUITS.
M. DEVICES INSTALLED IN 2X2 CEILING TILE SHALL BE CENTERED IN THE TILE.
DEVICES INSTALLED IN 2X4 CEILING TILE SHALL BE CENTERED IN 2X2
PORTION OF 2X4 TILE.
N. FIRE ALARM STROBES SHALL BE DUAL 'CLEAR FIRE' AND 'AMBER ALERT'
DEVICES.
O. COORDINATE DEMOLITION AND NEW WORK AS TO NOT REMOVE SYSTEMS,
DEVICES, AND/OR ACCESSORIES NECESSARY FOR AREAS IN LATER
PHASES.
P. FIRE ALARM SCOPE: REMOVE EXISTING FIRE ALARM DEVICES, WIRING, AND
RACEWAYS IN THE PROJECT AREAS IN THEIR ENTIRETY. PROVIDE NEW
DEVICES, WIRING, AND RACEWAYS AS INDICATED. MODIFY/EXPAND
EXISTING SILENT KNIGHT FACU AND ASSOCIATED EQUIPMENT PANELS TO
MEET NEW SYSTEM DESIGN.
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMP
321 4 5 6 7 8 9 10
GENERAL NOTES
KEY PLAN
KEYNOTES
AREA A
B400 KEY PLAN
AREA B
AREA
A1
AREA C
ARCHITECT/ENGINEER OF RECORD
A/E:
CONSULTANT
C&S Engineers, Inc.
2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com
Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com
Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com
B
IM
/6
-3
B
E x p a n d
R e lo c a te
U rg e n t
C a re A n d
R e n o v a te s t F lo o r P a ti e n t C a re
/6
-3
.4
.M
E P
.r v t
/1
/2
:4
:5
A
M
EF201
B400 - LEVEL 1 - FIRE ALARM
PLAN
Expand and Renovate B400 for
Urgent and Primary Care
500 E Veterans St, Tomah, WI 54660
676-19-327
400/407
05/20/2021 A.BARTSCH T.INGLE
TRIPLE C - THE A&E GROUP
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
ISSUED FOR
CONSTRUCTION
SCALE: 1/8" = 1'-0"
B400 LEVEL 1 FLOOR PLAN - FIRE ALARM
1 EXISTING REMOTE FIRE ALARM ANNUNCIATOR PANEL
SHALL BE REINSTALLED. EXTEND/REFEED EXISTING
WIRING AS REQUIRED TO NEW LOCATION.
2 PROVIDE DUCT SMOKE DETECTOR - PHOTO ELECTRIC
TYPE AND 120V POWER CONNECTION AT MOTORIZED
DAMPER INSTALLED BY M.C. COORDINATE SMOKE
DETECTOR INSTALLATION AND CONNECTION WITH
M.C.
3 NEW LOCATION OF EXISTING FA POWER MODULE
PANEL. EXTEND CIRCUITS TO NEW LOCATION.
Revisions: Date:
ARCHITECT/ENGINEER OF RECORD
A/E:
CONSULTANT
C&S Engineers, Inc.
2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com
Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com
Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com
TRIPLE C - THE A&E GROUP
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
48553 5/20/2021 Anthony R. Nelson
S
S
SD
S
S
S
SD
SD
SD
SD
S
F
SD
S
SD
SD
S
S
S
S S
1 2 3 4 5 6 6.1 7 7.8 8 9 9.1 9.9 10 11 11.2 12 13 14 18171615
M.3
M
L
K.3
K
J.4
J.3
J
I.5
I.2
I
H.1
H
G
F.1
F
E
D
C
B
A
INFUSION ROOM
MECH
EXAM 1
CLEAN UTILITY - LOGISTICS
TLT
TEAM WORK AREA
MED
EQUIPMENT
STORAGE
EXAM 5
EXAM 3
EXAM 2
EXAM 4
CORRIDOR
OC22
CLEAN LINENS
SOILED UTILITY
75,CLG
75,CLG
15,CLG
15,CLG
30,CLG
EX NP-1-2
EX CP-1-2
EX CP-2-2
EX CP-6-2
CLG
CLG
CLG
CLG
CLG
CLG
CLG
SOILED UTILITY
EX CP-6-2.1
EX 4 CP-2-2
EX LS1-2
A. ALIGN DEVICES VERTICALLY WHERE LIGHTING, POWER, SPECIAL SYSTEMS,
AND FIRE ALARM DEVICES WITH DIFFERENT MOUNTING HEIGHTS ARE
INDICATED CLOSE TO OTHER DEVICES.
B. REFER TO THE ARCHITECTURAL ELEVATION AND DETAIL DRAWINGS FOR
COORDINATION OF ELECTRICAL DEVICES.
C. CUTTING, DRILLING, AND/OR BORING THROUGH STRUCTURAL MEMBERS IS
NOT ACCEPTABLE.
D. PROVIDE FIRE RATED SEALS ON PENETRATIONS IN FIRE RATED FLOORS
AND WALLS. COORDINATE RATED LOCATIONS WITH LIFE SAFETY CODE
PLAN DRAWINGS.
E. PROVIDE INSULATED BUSHINGS FOR ROUGH-IN AND CONDUIT SLEEVE
LOCATIONS PRIOR TO INSTALLATION OF ANY CABLING.
F. BRANCH CIRCUITS CONDUCTOR LENGTHS FROM PANEL LONGER THAN 100’
FOR 120V AND 200' FOR 277V SHALL BE #10 OR LARGER FOR ENTIRE
LENGTH OF CIRCUIT FOR LINE, NEUTRAL, AND GROUND WIRES.
G. PROVIDE DEDICATED NEUTRAL FOR EACH MULTIWIRE BRANCH CIRCUIT
PHASE CONDUCTOR.
H. FOR DEVICE LOCATIONS SPECIFIED FOR ROUGH-IN, UNLESS NOTED
OTHERWISE, PROVIDE DOUBLE GANG J-BOX WITH SINGLE GANG MUD RING
AND BLANK COVER PLATE. ROUTE 1"C. UP INTO CONCEALED ACCESSIBLE
CEILING SPACE. PROVIDE BUSHINGS AND PULL STRING IN CONDUIT.
I. INSTALL SMOKE DETECTORS AT LEAST 3'-0” FROM ANY HVAC SUPPLY
DIFFUSER.
J. PROVIDE DUCT SMOKE DETECTORS FOR CONTROL OF SMOKE DAMPERS.
PROVIDE ONE CONTROL RELAY AND ONE ALARM INDICATOR FOR EACH
DETECTOR. PROVIDE 120V POWER AT EACH DAMPER LOCATION.
COORDINATE INSTALLATION WITH MECHANICAL CONTRACTOR. INSTALL
DETECTORS A MINIMUM OF 6 DUCT WIDTHS FROM ANY AIR INLET. PROVIDE
SAMPLING TUBE THAT EXTENDS INTO THE AIR STREAM, AND MOUNT
DETECTOR IN CENTER OF VERTICAL DIMENSION OF THE DUCT. DUCT
SMOKE DETECTORS INSTALLED FOR INDIVIDUAL CONTROL OF FIRE/SMOKE
DAMPERS SHALL BE INSTALLED A MAXIMUM OF 5' FROM THE DAMPER, WITH
NO AIR OUTLETS OR INLETS BETWEEN THE DETECTOR AND THE DAMPER.
K. SET EACH FIRE ALARM SYSTEM SPEAKER UNITS TO BEST SUIT INDIVIDUAL
ROOM CHARACTERISTICS AND TO ENSURE ALARM SOUND LEVELS OF 15db
OVER AMBIENT LEVELS. FIRE ALARM SPEAKER/STROBE AND STROBE ONLY
DEVICES SHALL BE WHITE.
L. PROVIDE CIRCUIT BREAKER 'LOCK-ON' FOR FIRE ALARM POWER CIRCUITS.
M. DEVICES INSTALLED IN 2X2 CEILING TILE SHALL BE CENTERED IN THE TILE.
DEVICES INSTALLED IN 2X4 CEILING TILE SHALL BE CENTERED IN 2X2
PORTION OF 2X4 TILE.
N. FIRE ALARM STROBES SHALL BE DUAL 'CLEAR FIRE' AND 'AMBER ALERT'
DEVICES.
O. COORDINATE DEMOLITION AND NEW WORK AS TO NOT REMOVE SYSTEMS,
DEVICES, AND/OR ACCESSORIES NECESSARY FOR AREAS IN LATER
PHASES.
P. FIRE ALARM SCOPE: REMOVE EXISTING FIRE ALARM DEVICES, WIRING, AND
RACEWAYS IN THE PROJECT AREAS IN THEIR ENTIRETY. PROVIDE NEW
DEVICES, WIRING, AND RACEWAYS AS INDICATED. MODIFY/EXPAND
EXISTING SILENT KNIGHT FACU AND ASSOCIATED EQUIPMENT PANELS TO
MEET NEW SYSTEM DESIGN.
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMP
321 4 5 6 7 8 9 10
GENERAL NOTES
KEY PLAN
KEYNOTES
AREA A
B400 KEY PLAN
AREA B
AREA
A1
AREA C
ARCHITECT/ENGINEER OF RECORD
A/E:
CONSULTANT
C&S Engineers, Inc.
2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com
Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com
Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com
B
IM
/6
-3
B
E x p a n d
R e lo c a te
U rg e n t
C a re A n d
R e n o v a te s t F lo o r P a ti e n t C a re
/6
-3
.4
.M
E P
.r v t
/1
/2
:4
:5
A
M
EF202
B400 - LEVEL 2 - FIRE ALARM
PLAN
Expand and Renovate B400 for
Urgent and Primary Care
500 E Veterans St, Tomah, WI 54660
676-19-327
400/407
05/20/2021 A.BARTSCH T.INGLE
TRIPLE C - THE A&E GROUP
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
ISSUED FOR
CONSTRUCTION
SCALE: 1/8" = 1'-0"
B400 LEVEL 2 FLOOR PLAN - FIRE ALARM
1 EXISTING FIRE ALARM POWER PANELS.
Revisions: Date:
ARCHITECT/ENGINEER OF RECORD
A/E:
CONSULTANT
C&S Engineers, Inc.
2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com
Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com
Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com
TRIPLE C - THE A&E GROUP
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
48553 5/20/2021 Anthony R. Nelson
SD
S
S
SD
J
S
S
S
SD
SD
OFFICE
3790A
MECH / ELECT
3790C
OFFICE
3775B
OPEN OFFICE
OFFICE
3790B
BEDROOM
BEDROOM
MECHANICAL ROOM
3780A
MECH / ELEC
MECHANICAL ROOM
BEDROOM
MEDS
3711A
BEDROOM
STORAGE
DINING
3749A
BREAK
3765 BEDROOM
WARD
READING
BEDROOM
TREATMENT
CT CLINIC
TOILET
3744A
CLOSET
RESTROOM
RESTROOM
SHOWERS
3784A
DRESSING
DRESSING
SHOWERS
3715A
Room
DAY ROOM
TOILET
CLOSET
3750A
CORRIDOR
7C36
CORRIDOR
7C31
DATA CLOSET
3772A
ELECTRICAL
CORRIDOR
7C38
CORRIDOR
7C39
OFFICE
STAIR
S4
CORRIDOR
7C37
CORRIDOR
7C32
HAC
3736A
NURSES
BEDROOM
BEDROOM
READING
UTILITY
WARD
STAIR
S6
DINING
LOCKERS
WARD
BEDROOM
BEDROOM
CLEAN LINENS
Room
CLOSET
ELEVATOR LOBBY
7C35
ELEVATOR
CORRIDOR
CORRIDOR
7C33
BEDROOM
LAUNDRY
OPEN OFFICE
407.A
407.B1
407.C1
407.D1
407.E
407.F
407.G1
407.H
407.I
407.J
407.K
407.L
407.M
407.N
407.14407.11 407.12.1407.12
407.9407.7
407.41407.4407.3407.21
J.39
J.40
J.41
407.H2
407.H1
407.13.1
EX CP3-3
EX CP1-3
EX LS1-3
EX NP1-3
EX FACU
PE
PE
75,CLG
75,CLG
75,CLG
75,CLG
CLG
CLG
CLG
DPE
DPE
DEDUCT ALT 1:
REMOVE WORK
ASSOCIATED WITH
B407 NORTH.
DEDUCT ALT 2:
REMOVE WORK
ASSOCIATED WITH
B407 SOUTH.
DEDUCT ALT 2:
REMOVE WORK
ASSOCIATED WITH
B407 SOUTH.
A. ALIGN DEVICES VERTICALLY WHERE LIGHTING, POWER, SPECIAL SYSTEMS,
AND FIRE ALARM DEVICES WITH DIFFERENT MOUNTING HEIGHTS ARE
INDICATED CLOSE TO OTHER DEVICES.
B. REFER TO THE ARCHITECTURAL ELEVATION AND DETAIL DRAWINGS FOR
COORDINATION OF ELECTRICAL DEVICES.
C. CUTTING, DRILLING, AND/OR BORING THROUGH STRUCTURAL MEMBERS IS
NOT ACCEPTABLE.
D. PROVIDE FIRE RATED SEALS ON PENETRATIONS IN FIRE RATED FLOORS
AND WALLS. COORDINATE RATED LOCATIONS WITH LIFE SAFETY CODE
PLAN DRAWINGS.
E. PROVIDE INSULATED BUSHINGS FOR ROUGH-IN AND CONDUIT SLEEVE
LOCATIONS PRIOR TO INSTALLATION OF ANY CABLING.
F. BRANCH CIRCUITS CONDUCTOR LENGTHS FROM PANEL LONGER THAN 100’
FOR 120V AND 200' FOR 277V SHALL BE #10 OR LARGER FOR ENTIRE
LENGTH OF CIRCUIT FOR LINE, NEUTRAL, AND GROUND WIRES.
G. PROVIDE DEDICATED NEUTRAL FOR EACH MULTIWIRE BRANCH CIRCUIT
PHASE CONDUCTOR.
H. FOR DEVICE LOCATIONS SPECIFIED FOR ROUGH-IN, UNLESS NOTED
OTHERWISE, PROVIDE DOUBLE GANG J-BOX WITH SINGLE GANG MUD RING
AND BLANK COVER PLATE. ROUTE 1"C. UP INTO CONCEALED ACCESSIBLE
CEILING SPACE. PROVIDE BUSHINGS AND PULL STRING IN CONDUIT.
I. INSTALL SMOKE DETECTORS AT LEAST 3'-0” FROM ANY HVAC SUPPLY
DIFFUSER.
J. PROVIDE DUCT SMOKE DETECTORS FOR CONTROL OF SMOKE DAMPERS.
PROVIDE ONE CONTROL RELAY AND ONE ALARM INDICATOR FOR EACH
DETECTOR. PROVIDE 120V POWER AT EACH DAMPER LOCATION.
COORDINATE INSTALLATION WITH MECHANICAL CONTRACTOR. INSTALL
DETECTORS A MINIMUM OF 6 DUCT WIDTHS FROM ANY AIR INLET. PROVIDE
SAMPLING TUBE THAT EXTENDS INTO THE AIR STREAM, AND MOUNT
DETECTOR IN CENTER OF VERTICAL DIMENSION OF THE DUCT. DUCT
SMOKE DETECTORS INSTALLED FOR INDIVIDUAL CONTROL OF FIRE/SMOKE
DAMPERS SHALL BE INSTALLED A MAXIMUM OF 5' FROM THE DAMPER, WITH
NO AIR OUTLETS OR INLETS BETWEEN THE DETECTOR AND THE DAMPER.
K. SET EACH FIRE ALARM SYSTEM SPEAKER UNITS TO BEST SUIT INDIVIDUAL
ROOM CHARACTERISTICS AND TO ENSURE ALARM SOUND LEVELS OF 15db
OVER AMBIENT LEVELS. FIRE ALARM SPEAKER/STROBE AND STROBE ONLY
DEVICES SHALL BE WHITE.
L. PROVIDE CIRCUIT BREAKER 'LOCK-ON' FOR FIRE ALARM POWER CIRCUITS.
M. DEVICES INSTALLED IN 2X2 CEILING TILE SHALL BE CENTERED IN THE TILE.
DEVICES INSTALLED IN 2X4 CEILING TILE SHALL BE CENTERED IN 2X2
PORTION OF 2X4 TILE.
N. FIRE ALARM STROBES SHALL BE DUAL 'CLEAR FIRE' AND 'AMBER ALERT'
DEVICES.
O. COORDINATE DEMOLITION AND NEW WORK AS TO NOT REMOVE SYSTEMS,
DEVICES, AND/OR ACCESSORIES NECESSARY FOR AREAS IN LATER
PHASES.
P. FIRE ALARM SCOPE: REMOVE EXISTING FIRE ALARM DEVICES, WIRING, AND
RACEWAYS IN THE PROJECT AREAS IN THEIR ENTIRETY. PROVIDE NEW
DEVICES, WIRING, AND RACEWAYS AS INDICATED. MODIFY/EXPAND
EXISTING SILENT KNIGHT FACU AND ASSOCIATED EQUIPMENT PANELS TO
MEET NEW SYSTEM DESIGN.
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMP
321 4 5 6 7 8 9 10
GENERAL NOTES
B407 KEY PLAN
AREA A
KEY PLAN
ARCHITECT/ENGINEER OF RECORD
A/E:
CONSULTANT
C&S Engineers, Inc.
2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com
Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com
Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com
B
IM
/6
-3
B
E x p a n d
R e lo c a te
U rg e n t
C a re A n d
R e n o v a te s t F lo o r P a ti e n t C a re
/6
-3
.4
.M
E P
.r v t
/1
/2
:4
:0
A
M
EF203-407
B407 - LEVEL 3 - FIRE ALARM
PLAN
Expand and Renovate B400 for
Urgent and Primary Care
500 E Veterans St, Tomah, WI 54660
676-19-327
400/407
05/20/2021 A.BARTSCH T.INGLE
TRIPLE C - THE A&E GROUP
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
ISSUED FOR
CONSTRUCTION
SCALE: 1/8" = 1'-0"
B407 LEVEL 3 FLOOR PLAN - FIRE ALARM
Revisions: Date:
ARCHITECT/ENGINEER OF RECORD
A/E:
CONSULTANT
C&S Engineers, Inc.
2575 E. Camelback Rd, Suite 740 Phoenix, AZ 85016 Phone: 602-997-7536 Fax: 602-997-7592 www.cscos.com
Obernel 1331 Tyler Street NE Suite 201 Minneapolis, MN 55413 Phone: (612) 249-5600 www.obernel.com
Hinman Consulting Engineers 601 California Street Suite 1710 San Francisco, CA 94108 Phone: 415-621-4423 www.hce.com
TRIPLE C - THE A&E GROUP
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
48553 5/20/2021 Anthony R. Nelson
| GI000-COVER SHEET |
| GI001-PROJECT SHEET INDEX |
| GI050-GENERAL NOTES |
| GI101-B400 -LEVEL 1 -FIRE AND LIFE SAFETY PLAN & CODE DATA |
| GI102-B400 -LEVEL 2 -FIRE AND LIFE SAFETY PLAN & CODE DATA |
| GI104-B407 -LEVEL 3 -FIRE AND LIFE SAFETY PLAN & CODE DATA -DEDUCT ALT #1 & #2 |
| GI201-INFECTION CONTROL PLAN & INTERIM LIFE |
| GC101-PROJECT PHASING |
| GC102-PHASING PLANS |
| H101-B400 -LEVEL 1 -HAZARDOUS MATERIAL ABATEMENT |
| H102-B400 -LEVEL 2 -HAZARDOUS MATERIAL ABATEMENT |
| H103-407-B407 -LEVEL 3 -HAZARDOUS MATERIAL ABATEMENT |
| HC101-B400 -LEVEL 1 -HAZARDOUS MATERIAL ABATEMENT -PIPING |
| VF100-CONTROL POINT SITE PLAN |
| VF101-viuvTiiig i iuvCIVIL SURVEY PLAN |
| CD101-CIVIL DEMOLITION PLAN |
| CS101-CIVIL SITE PLAN |
| COo-CIVIL SITE PLAN STAGING AREA |
| CG101-CIVIL GRADING PLAN |
| CG501-CIVIL DETAIL SHEET 1 |
| CG502-CIVIL DETAIL SHEET 2 |
| CU101-CIVIL UTILITY PLAN |
| SJ001-GENERAL STRUCTURAL NOTES |
| SJ002-GENERAL STRUCTURAL NOTES CONTINUED |
| SJ003-SPECIAL INSPECTIONS |
| SB100-B400 -LEVEL 1 -FOUNDATION PLAN -OVERALL |
| SB101-B400 -LEVEL 1 - FOUNDATION PLAN -AREA A |
| SF102-B400 -LEVEL 2 - FRAMING PLAN -OVERALL |
| SF103-B400 -LEVEL 2 -ROOF FRAMING PLAN -AREA A |
| SF201-FRAMING ELEVATIONS |
| SF202-FRAMING ELEVATIONS |
| SF203-FRAMING ELEVATIONS |
| SF501-TYPICAL DETAILS |
| SF502-TYPICAL DETAILS |
| SF503-TYPICAL DETAILS |
| SF504-TYPICAL DETAILS |
| SF505-TYPICAL DETAILS |
| SB510-FOUNDATION DETAILS |
| SF520-FRAMING DETAILS |
| SF521-FRAMING DETAILS |
| SF530-COLD-FORMED STEEL FRAMING |
| SF601-GRAPHICAL COLUMN SCHEDULE |
| AE000-SYMBOLS, & GENERAL NOTES |
| AS101-ARCHITECTURAL SITE PLAN |
| AG100-FLOOR PLAN -LEVEL 1, URGENT CARE CENTER PROGRAM PLAN |
| AG103-FLOOR PLAN -LEVEL 1, CLINICAL SPACE PROGRAM PLAN |
| AG200-FLOOR PLAN -LEVEL 2, SPECIALTY CARE PROGRAM PLAN |
| AG201A-FLOOR PLAN -LEVEL 3 -SWING SPACE LAYOUT B407-DEDUCT ALT #1 & #2 |
| AD101-B400 -LEVEL 1 -DEMOLITION PLAN |
| AD102-B400 -LEVEL 2 -DEMOLITION PLAN |
| AD103-407-B407 -LEVEL 3 -DEMOLITION PLAN -DEDUCT AL #1 & #2 |
| AD121-B400 -LEVEL 1 -DEMOLITION RCP |
| AD122-B400 -LEVEL 2 -DEMOLITION RCP |
| AD123-407-B407 -LEVEL 3 -DEMOLITION RCP -DEDUCT ALT #1 & #2 |
| AE101-B400 -LEVEL 1 -FLOOR PLAN -OVERALL |
| AE102-B400 -LEVEL 2 -FLOOR PLAN -OVERALL |
| AE103-407-B407 -LEVEL 3 -FLOOR PLAN -DEDUCT ALT #1& #2 |
| AE104-B400 -ROOF PLAN -OVERALL |
| AC101-B400 -LEVEL 1 -REFLECTED CEILING PLAN |
| AC102-B400 -LEVEL 2 -REFLECTED CEILING PLAN |
| AC103-407-B407 -LEVEL 3 -REFLECTED CEILING PLAN -DEDUCT ALT #1 & #2 |
| AE201-B400 EXTERIOR ELEVATIONS |
| AE201-407-B407 EXTERIOR ELEVATIONS -DEDUCT ALT #1 & #2 |
| AE202-B400 EXTERIOR ELEVATIONS |
| AE301-BUILDING SECTIONS |
| AE320-WALL SECTIONS |
| AE321-WALL SECTIONS |
| AE322-WALL SECTIONS |
| AE401-B400 -LEVEL 1 -ENLARGED FLOOR PLANS |
| AE401A-B400 -LEVEL 1 -ENLARGED FLOOR PLANS |
| AE401B-B400 -LEVEL 1 -ENLARGED FLOOR PLANS |
| AE401C-B400 -LEVEL 1 -ENLARGED FLOOR PLANS |
| AE401D-B400 -LEVEL 1 -ENLARGED FLOOR PLANS |
| AE402-B400 -LEVEL 2 -ENLARGED FLOOR PLANS |
| AE500-EXTERIOR WALL AND ROOF ASSEMBLIES |
| AE520-EXTERIOR SECTION DETAILS |
| AE521-EXTERIOR SECTION DETAILS |
| AE551-DETAILS -INTERIOR |
| AE552-DETAILS -INTERIOR |
| AE560-DOOR DETAILS |
| AE561-DOOR AND LOUVER DETAILS |
| AE601-DOOR WINDOW & LOUVER SCHEDULES |
| AE710-ARCHITECTURAL DOOR, WINDOW & FRAME TYPES |
| AE720-STANDARD PARTITION TYPES |
| AE721-PARTITION HEAD DETAILS |
| AE722-PARTITION FRAMING DETAILS |
| AE730-TYPICAL MOUNTING HEIGHTS |
| AG900-B400 RENDERINGS |
| AG901-B400 RENDERINGS |
| AG902-B400/ B407 RENDERINGS |
| AW001-SIGNAGE ABBREVIATIONS, SYMBOLS, GENERAL NOTES & DETAILS |
| AW101-B400 -LEVEL 1 -SIGNAGE PLAN |
| AW102-B400 -LEVEL 2 -SIGNAGE PLAN |
| AW103-B407 -LEVEL 3 -SIGNAGE PLAN -DEDUCT ALT #1 & #2 |
| IN001-NTERIOR FINISH ABBREVIATIONS, SYMBOLS, GENERAL NOTES & FINISH BOARDS |
| IN101-B400 -LEVEL 1 -INTERIOR FINISH PLAN -OVERALL |
| IN101A-B400 -LEVEL 1 -INTERIOR FINISH PLANS -AREA & A1 |
| IN101B-B400 -LEVEL 1 -INTERIOR FINISH PLANS -AREA |
| IN102C-B400 -LEVEL 2 -INTERIOR FINISH PLANS -AREA C |
| IN103D-B407 -LEVEL 3 -INTERIOR FINISH PLANS -AREA A, B & C -DEDUCT ALT #1& #2 |
| IN501-INTERIOR FINISH DETAILS |
| IN601-INTERIOR FINISH LEGEND AND SCHEDULES |
| IF101AB-B400 -LEVEL 1 -INTERIOR FURNITURE PLAN -FOR REFERENCE ONLY |
| IF102C-B400 -LEVEL 2 -INTERIOR FURNITURE PLAN -FOR REFERENE ONLY |
| IF103D-B407 -LEVEL 3 -INTERIOR FURNITURE PLAN -FOR REFERENCE ONLY -DEDUCT ALT #1 & #2 |
| IF104-FURNITURE PLAN -FOR REFERENCE ONLY |
| IF105-FURNITURE PLAN -FOR REFERENCE ONLY |
| IF106-FURNITURE PLAN -FOR REFERENCE ONLY |
| Q001-EQUIPMENT SCHEDULE |
| Q101AB-B400 -LEVEL 1 -EQUIPMENT PLANS |
| Q101C-B400 -LEVEL 2 -EQUIPMENT PLAN |
| F000-FIRE PROTECTION ABBREVIATIONS AND SYMBOLS |
| FD101-B400 -LEVEL 1 - FIRE PROTECTION DEMOLITION PLAN |
| FD102-B400 -LEVEL 2 - FIRE PROTECTION DEMOLITION PLAN |
| FD103-407-B407 -LEVEL 3 - FIRE PROTECTION DEMOLITION PLAN |
| FP101-B400 -LEVEL 1 - FIRE PROTECTION PLAN |
| FP102-B400 -LEVEL 2 - FIRE PROTECTION PLAN |
| FP103-407-B407 -LEVEL 3 - FIRE PROTECTION PLAN |
| P-000-PLUMBING ABBREVIATIONS AND SYMBOLS |
| PD100-B400 -FOUNDATION -PLUMBING DEMOLITION PLAN |
| PD101-B400 -LEVEL 1 -PLUMBING DEMOLITION PLAN |
| PD102-B400 -LEVEL 2 -PLUMBING DEMOLITION PLAN |
| PD201-B400 -LEVEL 1 -MED GAS DEMOLITION PLAN |
| P-100-B400 -FOUNDATION -PLUMBING PLAN |
| P-101-B400 -LEVEL 1 -PLUMBING PLAN |
| P-102-B400 -LEVEL 2 -PLUMBING PLAN |
| P103-407-B407 -LEVEL 3 -PLUMBING PLAN |
| P-201-B400 -LEVEL 1 -MED GAS PLAN |
| P-300-B400 -PLUMBING ENLARGED PLANS |
| P-301-B400 -PLUMBING ENLARGED PLANS |
| P-302-B400 -PLUMBING ENLARGED PLANS |
| P-303-B400 -PLUMBING ENLARGED PLANS |
| P-304-B400 -PLUMBING ENLARGED PLANS |
| P-305-B400 -PLUMBING ENLARGED PLANS |
| P-400-PLUMBING RISERS |
| P-401-PLUMBING RISERS |
| P-402-PLUMBING RISERS |
| P-403-PLUMBING RISERS |
| P-404-PLUMBING RISERS |
| P-500-PLUMBING DETAILS |
| P-700-PLUMBING SCHEDULES |
| M-000-MECHANICAL ABBREVIATIONS AND SYMBOLS |
| MD101-B400 -LEVEL 1 -HVAC DEMOLITION PLAN |
| MD101A-B400 -LEVEL 1 -HVAC DEMO PLAN -DEDUCT ALT. #4 |
| MD102-B400 -LEVEL 2 -HVAC DEMOLITION PLAN |
| MD103-407-B407 -LEVEL 3 -HVAC DEMOLITION PLAN |
| MD200-B400 -FOUNDATION -HVAC PIPING DEMOLITION PLAN |
| MD201-B400 -LEVEL 1 -HVAC PIPING DEMOLITION PLAN |
| MD202-B400 -LEVEL 2 -HVAC PIPING DEMOLITION PLAN |
| M-100-B400 -LEVEL 1 -HVAC TEMPORARY PLAN |
| M-101-B400 -LEVEL 1 - HVAC PLAN |
| M-101A-B400 -LEVEL 1 - HVAC PLAN -DEDUCT ALT. #4 |
| M-102-B400 -LEVEL 2 - HVAC PLAN |
| M-103-407-B407 -LEVEL 3 - HVAC PLAN |
| MP200-B400 -FOUNDATION -HVAC PIPING PLAN |
| MP201-B400 -LEVEL 1 -HVAC PIPING PLAN |
| MP202-B400 -LEVEL 2 -HVAC PIPING PLAN |
| MP203-407-B407 -LEVEL 3 -HVAC PIPING PLAN |
| M-400-ENLARGED MECHANICAL PLANS |
| M-401-ENLARGED MECHANICAL PLANS |
| M-402-ENLARGED MECHANICAL PLANS -DEDUCT ALT. #4 |
| M-500-MECHANICAL DETAILS |
| M-501-MECHANICAL DETAILS |
| M-502-MECHANICAL DETAILS |
| M-600-MECHANICAL SECTIONS |
| M-700-MECHANICAL SCHEDULES |
| M-800-MECHANICAL CONTROLS |
| M-801-MECHANICAL CONTROLS |
| M-802-MECHANICAL CONTROLS |
| E-000-ELECTRICAL ABBREVIATIONS AND SYMBOLS |
| ED101-B400 -LEVEL 1 - ELECTRICAL DEMOLITION PLAN |
| ED102-B400 -LEVEL 2 - ELECTRICAL DEMOLITION PLAN |
| ED103-407-B407 -LEVEL 3 - ELECTRICAL DEMOLITION PLAN |
| EL101-B400 -LEVEL 1 - LIGHTING PLAN |
| EL102-B400 -LEVEL 2 - LIGHTING PLAN |
| EL103-407-B407 -LEVEL 3 - LIGHTING PLAN |
| EL111-B400 -LEVEL 1 -LIGHTING CALCS |
| EL112-B400 -LEVEL 2 -LIGHTING CALCS |
| EL113-407-B407 -LEVEL 3 -LIGHTING CALCS |
| EP101-B400 -LEVEL 1 - POWER PLAN |
| EP102-B400 -LEVEL 2 - POWER PLAN |
| EP103-407-B407 -LEVEL 3 - POWER PLAN |
| EY101-B400 -LEVEL 1 - SPECIAL SYSTEMS PLAN |
| EY102-B400 -LEVEL 2 - SPECIAL SYSTEMS PLAN |
| EY103-407-B407 -LEVEL 3 - SPECIAL SYSTEMS PLAN |
| E-501-ELECTRICAL DETAILS |
| E-601-B400 ELECTRICAL DIAGRAMS |
| E-602-B400 ELECTRICAL DIAGRAMS |
| E-700-ELECTRICAL SCHEDULES |
| EF101-B400 -LEVEL 1 - FIRE ALARM DEMOLITION PLAN |
| EF102-B400 -LEVEL 2 - FIRE ALARM DEMOLITION PLAN |
| EF103-407-B407 -LEVEL 3 - FIRE ALARM DEMOLITION PLAN |
| EF201-B400 -LEVEL 1 - FIRE ALARM PLAN |
| EF202-B400 -LEVEL 2 - FIRE ALARM PLAN |
| EF203-407-B407 -LEVEL 3 - FIRE ALARM PLAN |
File details come from the government source that posted it. Updated .