Attachment 6 - 537-21-700 JBMC EHRM - Drawings - Set 3.pdf
PDF 36 MB Posted
- Solicitation number
- 36C77625B0049
View the file
Other files
Show all 42
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AREA
OF
WORK
W POLK ST
W TAYLOR ST
W O
G D E N A
V E
S D
A M
E N
S T
INTERSTATE 290
1B 1A
11B
11A
GARAGE
V.B.A.
OFFICE
BLDG
T E
M P
TAYLOR STREET
O G D
EN
A V
EN
U E
S O
U T
H D
A M
E N
A V
E N
U E
POLK STREET
AREA OF WORK
LEGEND - PROJECT MAP
1C
STRUCTURAL
MECHANICAL
IMEG Corp.
1100 Warrenville Road, Suite 400W Naperville, IL 60563 Phone: 630.753.8525 Contact: Matt Mears E-mail: matthew.r.mears@imegcorp.com
Calibre Engineering, Inc.
9090 S. Ridgeline Blvd. Suite 105 HIghlands Ranch, CO 80129 Phone: 303.951.8943 Contact: Ed Sabia E-mail: esabia@calibre-engineering.com
ARCHITECT
NAGEL Architects + Engineers 13890 Bishops Drive, Suite 250 Brookfield, WI 53005 Phone: 262.649.1883 Contact: Greg Nagel E-mail: greg.nagel@nagel.us
FIRE PROTECTION
IMEG Corp.
1100 Warrenville Road, Suite 400W Naperville, IL 60563 Phone: 314.951.2535 Contact: Scott R. Przybysz E-mail: scott.r.przybysz@imegcorp.com
ELECTRICAL
IMEG Corp.
1100 Warrenville Road, Suite 400W Naperville, IL 60563 Phone: 779.771.6240 Contact: Anthony Vansant E-mail: anthony.j.vansant@imegcorp.com
PLUMBING
IMEG Corp.
1100 Warrenville Road, Suite 400W Naperville, IL 60563 Phone: 630.753.8525 Contact: Matt Mears E-mail: matthew.r.mears@imegcorp.com
CIVIL
Calibre Engineering, Inc.
9090 S. Ridgeline Blvd. Suite 105 HIghlands Ranch, CO 80129 Phone: 303.339.6272 Contact: Jordan Dillard E-mail: jdillard@calibre-engineering.com
BLAST DESIGN
HOHBACH-LEWIN, INC.
909 Montgomery Street, Suite 260 San Francisco, CA 94133 Phone: 415.610.5793 Contact: Andrew Arnold E-mail: aarnold@hohbach-lewin.com
TELECOMMUNICATIONS
IMEG Corp.
1100 Warrenville Road, Suite 400W Naperville, IL 60563 Phone: 608.221.6716 Contact: Marty Witt E-mail: martin.a.witt@imegcorp.com
DESIGNER LIST AND STAMPS
13890 Bishops Drive, Suite 250 Brookfield, WI 53005
DEPARTMENT OF VETERANS AFFAIRS
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
NAGEL A+E PROJECT NUMBER:VA PROJECT NUMBER:
Building Number
Drawing NumberLocation
Issue Date Checked Drawn
Approved:
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
NOT FOR CONSTRUCTION
Project NumberProject TitleDrawing Title Phase
NAGEL
project number:
1100 Warrenville Road Suite 400W Naperville, IL 60563
829 Wisconsin Ave Racine, WI 53403
C U s e rs \r o if .N
A G
E L
\O n e D ri v e
N a g e l S e rv ic e s L
L C
\D o c u m e n ts \J e s s e
B ro w n E
H R
M I n fr a s tr u c tu re U p g ra d e s
F
IN
A L
C D ro i.
fo n ta n .r v t
/1
/2
:5 :2
P
M
JESSE BROWN VAMC EHRM INFRASTRUCTURE UPGRADES
820 S DAMEN AVE, CHIGAGO, IL 60612
21011537-21-700
G001.3
COVER SHEET JESSE BROWN VAMC EHRM
INFRASTRUCTURE UPGRADES
820 S DAMEN AVE, CHIGAGO, IL 60612
537-21-700
VA BLDG
18 AUG 2025 RF RB
FULLY SPRINKLERED
ISSUED FOR BID &
CONSTRUCTION
21011
ISSUED FOR BID & CONSTRUCTION
PROJECT SITE MAP
PROJECT LOCATION MAP
PERSPECTIVE
SHEET # SHEET NAME
40E-TD107 BUILDING 40E - SEVENTH FLOOR DEMO PLAN – TECHNOLOGY
40E-TN101 BUILDING 40E - FIRST FLOOR PLAN – TECHNOLOGY
40E-TN102 BUILDING 40E - SECOND FLOOR PLAN – TECHNOLOGY
40E-TN103 BUILDING 40E - THIRD FLOOR PLAN – TECHNOLOGY
40E-TN104 BUILDING 40E - FOURTH FLOOR PLAN – TECHNOLOGY
40E-TN105 BUILDING 40E - FIFTH FLOOR PLAN – TECHNOLOGY
40E-TN106 BUILDING 40E - SIXTH FLOOR PLAN – TECHNOLOGY
40E-TN107 BUILDING 40E - SEVENTH FLOOR PLAN – TECHNOLOGY
40W-TD101 BUILDING 40W - FIRST FLOOR DEMO PLAN – TECHNOLOGY
40W-TD102 BUILDING 40W - SECOND FLOOR DEMO PLAN – TECHNOLOGY
40W-TD103 BUILDING 40W - THIRD FLOOR DEMO PLAN – TECHNOLOGY
40W-TD104 BUILDING 40W - FOURTH FLOOR DEMO PLAN – TECHNOLOGY
40W-TD105 BUILDING 40W - FIFTH FLOOR DEMO PLAN – TECHNOLOGY
40W-TD106 BUILDING 40W - SIXTH FLOOR DEMO PLAN – TECHNOLOGY
40W-TD107 BUILDING 40W - SEVENTH FLOOR DEMO PLAN – TECHNOLOGY
40W-TN101 BUILDING 40W - FIRST FLOOR PLAN – TECHNOLOGY
40W-TN102 BUILDING 40W - SECOND FLOOR PLAN – TECHNOLOGY
40W-TN103 BUILDING 40W - THIRD FLOOR PLAN – TECHNOLOGY
40W-TN104 BUILDING 40W - FOURTH FLOOR PLAN – TECHNOLOGY
40W-TN105 BUILDING 40W - FIFTH FLOOR PLAN – TECHNOLOGY
40W-TN106 BUILDING 40W - SIXTH FLOOR PLAN – TECHNOLOGY
40W-TN107 BUILDING 40W - SEVENTH FLOOR PLAN – TECHNOLOGY
40W-TN300 TR 40 - TECHNOLOGY ROOM ENLARGEMENTS
40W-TN301 TR 40 - TECHNOLOGY ROOM ENLARGEMENTS
40W-TN302 TR 40 - TECHNOLOGY ROOM ENLARGEMENTS
40W-TN303 TR 40 - TECHNOLOGY ROOM ENLARGEMENTS
T400 TECHNOLOGY RISER DIAGRAMS
T401 TECHNOLOGY RISER DIAGRAMS
T402 TECHNOLOGY RISER DIAGRAMS
T403 TECHNOLOGY RISER DIAGRAMS
T500 TECHNOLOGY DETAILS
T501 TECHNOLOGY DETAILS
T502 TECHNOLOGY DETAILS
T503 TECHNOLOGY DETAILS
T504 TECHNOLOGY DETAILS
T600 TECHNOLOGY SCHEDULES
SHEET # SHEET NAME
1B-TN110 BUILDING 1B - TENTH FLOOR PLAN – TECHNOLOGY
1B-TN300 TR 1B - TECHNOLOGY ROOM ENLARGEMENTS
1B-TN301 TR 1B - TECHNOLOGY ROOM ENLARGEMENTS
1B-TN302 TR 1B - TECHNOLOGY ROOM ENLARGEMENTS
11A-TD101 BUILDING 11A - FIRST FLOOR DEMO PLAN – TECHNOLOGY
11A-TD102 BUILDING 11A - SECOND FLOOR DEMO PLAN – TECHNOLOGY
11A-TD102.1 BUILDING 11A - SECOND FLOOR DEMO PLAN – TECHNOLOGY
11A-TD103 BUILDING 11A - THIRD FLOOR DEMO PLAN – TECHNOLOGY
11A-TD103.1 BUILDING 11A - THIRD FLOOR DEMO PLAN – TECHNOLOGY
11A-TD104 BUILDING 11A - FOURTH FLOOR DEMO PLAN – TECHNOLOGY
11A-TD104.1 BUILDING 11A - FOURTH FLOOR DEMO PLAN – TECHNOLOGY
11A-TD105 BUILDING 11A - FIFTH FLOOR DEMO PLAN – TECHNOLOGY
11A-TD105.1 BUILDING 11A - FIFTH FLOOR DEMO PLAN – TECHNOLOGY
11A-TD106 BUILDING 11A - SIXTH FLOOR DEMO PLAN – TECHNOLOGY
11A-TD106.1 BUILDING 11A - SIXTH FLOOR DEMO PLAN – TECHNOLOGY
11A-TD107 BUILDING 11A - SEVENTH FLOOR DEMO PLAN – TECHNOLOGY
11A-TD107.1 BUILDING 11A - SEVENTH FLOOR DEMO PLAN – TECHNOLOGY
11A-TN101 BUILDING 11A - FIRST FLOOR PLAN – TECHNOLOGY
11A-TN102 BUILDING 11A - SECOND FLOOR PLAN – TECHNOLOGY
11A-TN102.1 BUILDING 11A - SECOND FLOOR PLAN – TECHNOLOGY
11A-TN103 BUILDING 11A - THIRD FLOOR PLAN – TECHNOLOGY
11A-TN103.1 BUILDING 11A - THIRD FLOOR PLAN – TECHNOLOGY
11A-TN104 BUILDING 11A - FOURTH FLOOR PLAN – TECHNOLOGY
11A-TN104.1 BUILDING 11A - FOURTH FLOOR PLAN – TECHNOLOGY
11A-TN105 BUILDING 11A - FIFTH FLOOR PLAN – TECHNOLOGY
11A-TN105.1 BUILDING 11A - FIFTH FLOOR PLAN – TECHNOLOGY
11A-TN106 BUILDING 11A - SIXTH FLOOR PLAN – TECHNOLOGY
11A-TN106.1 BUILDING 11A - SIXTH FLOOR PLAN – TECHNOLOGY
11A-TN107 BUILDING 11A - SEVENTH FLOOR PLAN – TECHNOLOGY
11A-TN107.1 BUILDING 11A - SEVENTH FLOOR PLAN – TECHNOLOGY
11A-TN300 TR 11A - TECHNOLOGY ROOM ENLARGEMENTS
11A-TN301 TR 11A - TECHNOLOGY ROOM ENLARGEMENTS
11A-TN302 TR 11A - TECHNOLOGY ROOM ENLARGEMENTS
11A-TN303 TR 11A - TECHNOLOGY ROOM ENLARGEMENTS
11B-TD101 BUILDING 11B - FIRST FLOOR DEMO PLAN – TECHNOLOGY
11B-TD102 BUILDING 11B - SECOND FLOOR DEMO PLAN – TECHNOLOGY
11B-TD103 BUILDING 11B - THIRD FLOOR DEMO PLAN – TECHNOLOGY
11B-TD104 BUILDING 11B - FOURTH FLOOR DEMO PLAN – TECHNOLOGY
11B-TD105 BUILDING 11B - FIFTH FLOOR DEMO PLAN – TECHNOLOGY
11B-TD106 BUILDING 11B - SIXTH FLOOR DEMO PLAN – TECHNOLOGY
11B-TD107 BUILDING 11B - SEVENTH FLOOR DEMO PLAN – TECHNOLOGY
11B-TN101 BUILDING 11B - FIRST FLOOR PLAN – TECHNOLOGY
11B-TN102 BUILDING 11B - SECOND FLOOR PLAN – TECHNOLOGY
11B-TN103 BUILDING 11B - THRID FLOOR PLAN – TECHNOLOGY
11B-TN104 BUILDING 11B - FOURTH FLOOR PLAN – TECHNOLOGY
11B-TN105 BUILDING 11B - FIFTH FLOOR PLAN – TECHNOLOGY
11B-TN106 BUILDING 11B - SIXTH FLOOR PLAN – TECHNOLOGY
11B-TN107 BUILDING 11B - SEVENTH FLOOR PLAN – TECHNOLOGY
11B-TN301 TR 11B - TECHNOLOGY ROOM ENLARGEMENTS
11B-TN302 TR 11B - TECHNOLOGY ROOM ENLARGEMENTS
11B-TN303 TR 11B - TECHNOLOGY ROOM ENLARGEMENTS
11B-TN304 TR 11B - TECHNOLOGY ROOM ENLARGEMENTS
30-TD101 BUILDING 30 - FIRST FLOOR DEMO PLAN – TECHNOLOGY
30-TN101 BUILDING 30 - FIRST FLOOR PLAN – TECHNOLOGY
30-TN301 TR 30 -TECHNOLOGY ROOM ENLARGEMENTS
32-TD101 BUILDING 32 - FIRST FLOOR DEMO PLAN – TECHNOLOGY
32-TD102 BUILDING 32 - SECOND FLOOR DEMO PLAN – TECHNOLOGY
32-TN101 BUILDING 32 - FIRST FLOOR PLAN – TECHNOLOGY
32-TN102 BUILDING 32 - SECOND FLOOR PLAN – TECHNOLOGY
32-TN301 TR32 - TECHNOLOGY ROOM ENLARGEMENTS
40E-TD101 BUILDING 40E - FIRST FLOOR DEMO PLAN – TECHNOLOGY
40E-TD102 BUILDING 40E - SECOND FLOOR DEMO PLAN – TECHNOLOGY
40E-TD103 BUILDING 40E - THIRD FLOOR DEMO PLAN – TECHNOLOGY
40E-TD104 BUILDING 40E - FOURTH FLOOR DEMO PLAN – TECHNOLOGY
40E-TD105 BUILDING 40E - FIFTH FLOOR DEMO PLAN – TECHNOLOGY
40E-TD106 BUILDING 40E - SIXTH FLOOR DEMO PLAN – TECHNOLOGY
SHEET # SHEET NAME
15 - TECHNOLOGY - T
00-T000 TECHNOLOGY - LEGENDS, NOTES
00-TN101 FIRST FLOOR PLAN -TECHNOLOGY
00-TN102 SECOND FLOOR PLAN - TECHNOLOGY
00-TN103 FIRST FLOOR PLAN - TECHNOLOGY
00-TN104 FOURTH FLOOR PLAN - TECHNOLOGY
00-TN105 FIFTH FLOOR PLAN - TECHNOLOGY
00-TN106 SIXTH FLOOR PLAN - TECHNOLOGY
00-TN107 SEVENTH FLOOR PLAN - TECHNOLOGY
00-TN108 EIGHTH FLOOR PLAN - TECHNOLOGY
00-TN109 NINTH FLOOR PLAN- TECHNOLOGY
00-TN110 TENTH FLOOR PLAN - TECHNOLOGY
1AN-TD101 BUILDING 1A-N - FIRST FLOOR DEMO PLAN - TECHNOLOGY
1AN-TD102 BUILDING 1A-N - SECOND FLOOR DEMO PLAN - TECHNOLOGY
1AN-TD103 BUILDING 1A-N - THIRD FLOOR DEMO PLAN - TECHNOLOGY
1AN-TD104 BUILDING 1A-N - FOURTH FLOOR DEMO PLAN - TECHNOLOGY
1AN-TD105 BUILDING 1A-N - FIFTH FLOOR DEMO PLAN - TECHNOLOGY
1AN-TD106 BUILDING 1A-N - SIXTH FLOOR DEMO PLAN - TECHNOLOGY
1AN-TD107 BUILDING 1A-N - SEVENTH FLOOR DEMO PLAN - TECHNOLOGY
1AN-TD108 BUILDING 1A-N - EIGHTH FLOOR DEMO PLAN - TECHNOLOGY
1AN-TD109 BUILDING 1A-N - NINTH FLOOR DEMO PLAN - TECHNOLOGY
1AN-TD110 BUILDING 1A-N - TENTH FLOOR DEMO PLAN - TECHNOLOGY
1AN-TN101 BUILDING 1A-N - FIRST FLOOR PLAN - TECHNOLOGY
1AN-TN102 BUILDING 1A-N - SECOND FLOOR PLAN - TECHNOLOGY
1AN-TN103 BUILDING 1A-N - THIRD FLOOR PLAN - TECHNOLOGY
1AN-TN104 BUILDING 1A-N - FOURTH FLOOR PLAN - TECHNOLOGY
1AN-TN105 BUILDING 1A-N - FIFTH FLOOR PLAN - TECHNOLOGY
1AN-TN106 BUILDING 1A-N - SIXTH FLOOR PLAN - TECHNOLOGY
1AN-TN107 BUILDING 1A-N - SEVENTH FLOOR PLAN - TECHNOLOGY
1AN-TN108 BUILDING 1A-N - EIGHTH FLOOR PLAN - TECHNOLOGY
1AN-TN109 BUILDING 1A-N - NINTH FLOOR PLAN - TECHNOLOGY
1AN-TN110 BUILDING 1A-N - TENTH FLOOR PLAN - TECHNOLOGY
1AS-TD101 BUILDING 1A-S - FIRST FLOOR DEMO PLAN - TECHNOLOGY
1AS-TD102 BUILDING 1A-S - SECOND FLOOR DEMO PLAN - TECHNOLOGY
1AS-TD103 BUILDING 1A-S - THIRD FLOOR DEMO PLAN - TECHNOLOGY
1AS-TD104 BUILDING 1A-S - FOURTH FLOOR DEMO PLAN - TECHNOLOGY
1AS-TD105 BUILDING 1A-S - FIFTH FLOOR DEMO PLAN - TECHNOLOGY
1AS-TD106 BUILDING 1A-S - SIXTH FLOOR DEMO PLAN - TECHNOLOGY
1AS-TD107 BUILDING 1A-S - SEVENTH FLOOR DEMO PLAN - TECHNOLOGY
1AS-TD108 BUILDING 1A-S - EIGHTH FLOOR DEMO PLAN - TECHNOLOGY
1AS-TD109 BUILDING 1A-S - NINTH FLOOR DEMO PLAN - TECHNOLOGY
1AS-TD110 BUILDING 1A-S - TENTH FLOOR DEMO PLAN - TECHNOLOGY
1AS-TN101 BUILDING 1A-S - FIRST FLOOR PLAN - TECHNOLOGY
1AS-TN102 BUILDING 1A-S - SECOND FLOOR PLAN - TECHNOLOGY
1AS-TN103 BUILDING 1A-S - THIRD FLOOR PLAN - TECHNOLOGY
1AS-TN104 BUILDING 1A-S - FOUTH FLOOR PLAN - TECHNOLOGY
1AS-TN105 BUILDING 1A-S - FIFTH FLOOR PLAN - TECHNOLOGY
1AS-TN106 BUILDING 1A-S - SIXTH FLOOR PLAN - TECHNOLOGY
1AS-TN107 BUILDING 1A-S - SEVENTH FLOOR PLAN - TECHNOLOGY
1AS-TN108 BUILDING 1A-S - EIGHTH FLOOR PLAN - TECHNOLOGY
1AS-TN109 BUILDING 1A-S - NINTH FLOOR PLAN - TECHNOLOGY
1AS-TN110 BUILDING 1A-S - TENTH FLOOR PLAN - TECHNOLOGY
1AS-TN300 TR 1A - TECHNOLOGY ROOM ENLARGEMENTS
1AS-TN301 TR 1A - TECHNOLOGY ROOM ENLARGEMENTS
1AS-TN303 TR 1A - TECHNOLOGY ROOM ENLARGEMENTS
1AS-TN304 TR 1A - TECHNOLOGY ROOM ENLARGEMENTS
1AS-TN305 TR 1A - TECHNOLOGY ROOM ENLARGEMENTS
1AS-TN306 TECHNOLOGY ROOM ENLARGEMENTS
1AS-TN307 TECHNOLOGY ROOM ENLARGEMENTS
1B-TD101 BUILDING 1B - FIRST FLOOR DEMO PLAN – TECHNOLOGY
1B-TD102 BUILDING 1B - SECOND FLOOR DEMO PLAN – TECHNOLOGY
1B-TD103 BUILDING 1B - THIRD FLOOR DEMO PLAN – TECHNOLOGY
1B-TD104 BUILDING 1B - FOURTH FLOOR DEMO PLAN – TECHNOLOGY
1B-TD105 BUILDING 1B - FIFTH FLOOR DEMO PLAN – TECHNOLOGY
1B-TD106 BUILDING 1B - SIXTH FLOOR DEMO PLAN – TECHNOLOGY
1B-TD107 BUILDING 1B - SEVENTH FLOOR DEMO PLAN – TECHNOLOGY
1B-TD108 BUILDING 1B - EIGHTH FLOOR DEMO PLAN – TECHNOLOGY
1B-TD109 BUILDING 1B - NINTH FLOOR DEMO PLAN – TECHNOLOGY
1B-TD110 BUILDING 1B - TENTH FLOOR DEMO PLAN – TECHNOLOGY
1B-TN101 BUILDING 1B - FIRST FLOOR PLAN – TECHNOLOGY
1B-TN102 BUILDING 1B - SECOND FLOOR PLAN – TECHNOLOGY
1B-TN103 BUILDING 1B - THIRD FLOOR PLAN – TECHNOLOGY
1B-TN104 BUILDING 1B - FOURTH FLOOR PLAN – TECHNOLOGY
1B-TN105 BUILDING 1B - FIFTH FLOOR PLAN – TECHNOLOGY
1B-TN106 BUILDING 1B - SIXTH FLOOR PLAN – TECHNOLOGY
1B-TN107 BUILDING 1B - SEVENTH FLOOR PLAN – TECHNOLOGY
1B-TN108 BUILDING 1B - EIGHTH FLOOR PLAN – TECHNOLOGY
1B-TN109 BUILDING 1B - NINTH FLOOR PLAN – TECHNOLOGY
SHEET INDEX
SHEET # SHEET NAME
00.2 - GENERAL - G
G001.3 COVER SHEET
Revisions: Date:
Ryan Bourland Text Box
12 MAR 2025,
18 AUG 2025 R1
Ryan Bourland Line
TECHNOLOGY SYMBOL LIST
SYMBOL: DESCRIPTION: NOTE:
EQUIPMENT
LIST ABBREV.:
W
1.
CEILING INFORMATION OUTLET, COMBINATION
TELEPHONE/DATA COMMUNICATION
SC-IO-C
1.
WALL INFORMATION OUTLET, COMBINATION
TELEPHONE/DATA COMMUNICATION
SC-IO-W
1.
WALL INFORMATION OUTLET, WALL TELEPHONE
COMMUNICATION
SC-IO-W
1.
FLOOR INFORMATION OUTLET, DATA COMMUNICATION
ONLY
SC-IO-F
WAP
1.
CEILING INFORMATION OUTLET, DATA COMMUNICATION
ONLY, WIRELESS ACCESS POINT
SC-IO-C
TV
1.
WALL INFORMATION OUTLET, TELEVISION, MOUNTED AT
+84" UNLESS OTHERWISE NOTED
SC-IO-W
1.
FLOOR INFORMATION OUTLET, COMBINATION
TELEPHONE/DATA COMMUNICATION
SC-IO-F
1.
CEILING INFORMATION OUTLET, DATA COMMUNICATION
ONLY
SC-IO-C
M T .
CARD ACCESS READER; LETTER INDICATES AS
FOLLOWS:
M = MOUNT
C - CEILING D - DESK F- FLUSH H - HIDDEN M -
MULLION
P - PEDESTAL R - RACK S - SURFACE W - WALL
T = TECHNOLOGY/TYPE
B - BARCODE F - ELEVATOR FLOOR CALL
H - ELEVATOR HALL CALL M - MAG STRIP
P = PROXIMITY S - SMART CARD T - TOKEN
AC-CR1
CSS .
CONTROLLED SECURITY SCHEME SCHEDULE
IDENTIFIER
N/A
CCTV 2.
VIDEO SURVEILLANCE CAMERA WITH LENS,
WALL MOUNT OR CEILING MOUNTVS-CM-1
TECHNOLOGY ABBREVIATION KEY
TELECOMMUNICATIONS ROOMTR-#
ABOVE FINISHED FLOORAFF
BELOW FINISHED CEILINGBFC
CONDUITC
SIMILARSIM
TYPICALTYP
MOUNTING HEIGHT ABOVE FINISHED FLOOR+#
JUNCTION BOXJ-BOX
ABBR: DESCRIPTION:
UNLESS OTHERWISE NOTEDUON
FIELD OF VIEWFOV
DOUBLE POLE DOUBLE THROWDPDT
PAN TILT ZOOMPTZ
POWER OVER ETHERNETPOE
ABOVE FINISHED GRADEAFG
DELAYED EGRESSDE
TECHNOLOGY GENERAL NOTES:
1. ###-### INDICATES TECHNOLOGY EQUIPMENT SCHEDULE ITEM LABELED AS "EQUIPMENT
LIST ABBREVIATION"
2. REFER TO TECHNOLOGY EQUIPMENT SCHEDULE AND SPECIFICATIONS FOR FULL
DESCRIPTIONS AND MANUFACTURERS OF ALL DEVICES.
TECHNOLOGY MOUNTING SUBSCRIPT KEY:
A MOUNT AT +6" TO CENTERLINE ABOVE COUNTER OR BACKSPLASH
H MOUNT ORIENTED HORIZONTALLY
L MOUNT IN CASEWORK
M MOUNT IN MODULAR FURNITURE
S MOUNT IN SURFACE RACEWAY
A SLASH IS USED BETWEEN TWO SUBSCRIPTS, E.G., A/H.
1. THE COMPLETE INSTALLATION SHALL BE IN ACCORDANCE WITH THE ADA STANDARDS FOR
ACCESSIBLE DESIGN. REFER TO THE ADA GUIDELINES FOR ALL CONFIGURATION DETAILS
ON THIS PAGE FOR ADDITIONAL INFORMATION.
2. CONCEAL ALL CONDUIT IN WALLS, PARTITIONS, ABOVE CEILING, IN FLOOR SLAB, ETC.
UNLESS OTHERWISE INDICATED ON THE PLANS OR IN THE SPECIFICATIONS. CONDUIT IN
MECHANICAL ROOMS AND STORAGE ROOMS WITHOUT CEILINGS MAY BE EXPOSED ON
BUILDING STRUCTURE.
3. BOXES LOCATED ON OPPOSITE SIDES OF NON-RATED WALLS SHALL BE OFFSET A MINIMUM
OF 6" HORIZONTALLY. BOXES ON OPPOSITE SIDES OF FIRE RATED WALLS SHALL BE
OFFSET A MINIMUM OF 24" HORIZONTALLY. "THRU-THE-WALL" BOXES SHALL NOT BE
ALLOWED WITHOUT PRIOR WRITTEN APPROVAL OF THE ARCHITECT/ENGINEER.
4. VERIFY ALL FURNITURE, MODULAR FURNITURE, AND EQUIPMENT LOCATIONS WITH
ARCHITECTURAL PLANS, ELEVATIONS, AND REVIEWED SHOP DRAWINGS. PRIOR TO MAKING
THE ACTUAL TELECOMMUNICATIONS INSTALLATION, ADJUST OUTLETS OR CONNECTION
LOCATIONS TO ACCOMMODATE FURNITURE AND/OR EQUIPMENT.
5. TELECOMMUNICATIONS EQUIPMENT SHALL BE MOUNTED TO ALLOW ACCESS TO
ELECTRICAL AND MECHANICAL EQUIPMENT. ALL MOUNTING OF TELECOMMUNICATION
DEVICES ON EQUIPMENT SUPPLIED BY ANOTHER CONTRACTOR SHALL BE APPROVED IN
ADVANCE BY THE OTHER CONTRACTOR.
6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL OPENINGS REQUIRED IN WALLS. ALL
OPENINGS SHALL BE REPAIRED TO MATCH EXISTING BY A QUALIFIED CONTRACTOR AT THE
EXPENSE OF THIS CONTRACTOR. ALL CONDUITS THROUGH WALLS SHALL BE GROUTED OR
SEALED INTO OPENINGS.
7. ALL MATERIALS USED TO SEAL PENETRATIONS OF FIRE RATED WALLS AND FLOORS SHALL
BE TESTED AND CERTIFIED AS A SYSTEM PER ASTM E814 STANDARDS FOR FIRE TESTS OF
THROUGH-PENETRATION FIRESTOPS. REFER TO DIVISION 7 FOR ADDITIONAL INFORMATION
AND REQUIREMENTS SPECIFIC TO FIRESTOPPING.
8. THE TECHNOLOGY CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND REPLACEMENT OF
THE CEILINGS, CEILING TILES, AND CEILING GRID ASSOCIATED WITH THE AREAS OF WORK
BY ALL CONTRACTORS.
9. ALL LADDER RACK AND CABLE TRAY SIZES ARE AS DEFINED ON THE DRAWINGS. REFER TO
MANUFACTURERS DOCUMENTS FOR INSTALLATION REQUIREMENTS.
10. FLUSH MOUNT ALL TELECOMMUNICATION OUTLETS AT +18" FROM FLOOR (CENTERLINE
DIMENSION), EXCEPT WHERE OTHERWISE NOTED. OUTLETS MAY BE SURFACE MOUNTED
WHEN CONDUIT IS SPECIFIED EXPOSED.
11. EACH CONTRACTOR IS RESPONSIBLE FOR DAMAGE CAUSED BY THEIR ACTIONS TO THE
WALLS, FLOORS, CEILINGS, AND ROOFS. THE CONTRACTOR WHOSE WORK CAUSES
DAMAGE IS RESPONSIBLE FOR PATCHING TO MATCH ORIGINAL CONSTRUCTION, FIRE
RATING, AND FINISH.
12. ALL VERTICAL PATHWAYS IN THE EXISTING STRUCTURE SHALL BE SCANNED OR X-RAY'D
PRIOR TO CORING AND DRILLING. DAMAGES CAUSED WITHOUT PROPER SCANNING SHALL
BE REPAIRED WITHOUT COST TO THE OWER WITHIN 8 HOURS.
13. ALL ADDITIONAL FLOOR SLEEVES SHALL REQUIRE THE CONTRACTOR TO SCAN THE FLOOR
PRIOR TO CORING. NO WORK SHALL PROCEED WITHOUT VERIFICATION THE CORE
LOCATION IS CLEAR OF CONDUIT WITHIN THE DECK.
14. TEMPORARY FIRESTOPPING COMPOSED OF MINERAL WOOL SHALL BE INSTALLED IN ALL
WALL AND FLOOR PENETRATIONS AT THE END OF EVERY WORK SHIFT WHILE WORK IS IN
PROGRESS. UN-SEALED OPENINGS ARE NOT ALLOWED TO PROVIDE PROTECTION AGAINST
FIRE/SMOKE SPREAD THROUGH UN-SEALED PENETRATIONS.
15. RE-INSTALL CEILING TILES AT THE END OF EVERY WORK SHIFT DURING CABLE
INSTALLATION.
16. ALL BACKBOX INSTALLED IN A FIRE-RATED WALL SHALL BE INSTALLED WITH FIRE PUTTY
PADS.
TECHNOLOGY INSTALLATION NOTES:
GENERAL NOTES:
1. ALL SYMBOLS AND ABBREVIATIONS LISTED MAY NOT BE APPLICABLE TO THIS PROJECT.
REFER TO THE TECHNOLOGY EQUIPMENT SCHEDULE FOR MORE COMPLETE DESCRIPTION
AND ITEMS.
2. ALL SYMBOLS AND ABBREVIATIONS REFER TO TECHNOLOGY SHEETS ONLY AS DEFINED ON
THE SHEET INDEX. REFER TO THE GENERAL TECHNOLOGY NOTES FOR ADDITIONAL
INFORMATION.
3. ALL SYMBOLS LISTED ABOVE ARE FOR REFERENCE ONLY. REFER TO PLANS AND LINE TYPE
KEY FOR NEW, EXISTING TO REMAIN AND TO BE REMOVED ITEMS FOR ADDITIONAL
INFORMATION.
4. REFER TO RISERS ON SHEET(S): T400, T401, T402, T403.
TECHNOLOGY SYMBOL NOTES:
1. "#" INDICATES INFORMATION OUTLET FACEPLATE CONFIGURATION. REFER TO
INFORMATION OUTLET SCHEDULE ON T600 FOR ADDITIONAL INFORMATION.
2. "CM-#" ON FLOOR PLANS INDICATES CAMERA TYPE AND IS ASSOCIATED WITH THE
CORRESPONDING "VS-CM-#" EQUIPMENT SCHEDULE ABBREVIATION. "##-##" SUBSCRIPT
INDICATES FLOOR NUMBER-CAMERA NUMBER. REFER TO SHEET 1/T504 FOR CAMERA
MOUNTING DETAIL.
CABLE TRAY, CHANNEL TRAY, BASKET
TRAY
LADDER RACK
WIDTH X HEIGHT
WIDTH X HEIGHT
DIAMETERø C CONDUIT
CONDUIT DOWN
CONDUIT UP OR UP/DOWN
CONDUIT SLEEVE
CONTINUATION
SC-ER-1 FOUR POST EQUIPMENT RACK
N/A EXISTING TWO POST EQUIPMENT RACK
SC-VWM-1
N/A POWER POLE
VERTICAL WIRE MANAGER
SC-GND-1 WALL MOUNT GROUND BAR
PRIMARY FIBERP P P
SECONDARY FIBERS S S
WAP SC-IO-W WALL NFORMATION OUTLET, DATA COMMUNICATION
ONLY, WIRELESS ACCESS POINT
1.
#D
WALL NFORMATION OUTLET, DATA COMMUNICATION
ONLY
T
N/A CEILING NFORMATION OUTLET, TELEMETRY
SC-IO-W
PLAN OR DETAIL NUMBER
PLAN OR DETAIL NAME
PLAN OR DETAIL SCALE
DETAIL REFERRED TO BY SECTION CUT
SHEET DETAIL IS LOCATED ON
NAME
VIEW NAME
1/8" = 1'-0"
M101
SIMSIM
INDICATES SIMILAR DETAIL REFERENCED
IN MULTIPLE LOCATIONS
LEVEL NAME
10'-0" HEIGHT ABOVE
PROJECT 0'-0"
1 INDICATES NOTE USED TO DESCRIBE
ADDITIONAL INFORMATION ABOUT
WORK REQUIRED, SPECIFIC TO THE
SHEET AND/OR DETAIL
N
O R HT
INDICATES DIRECTION OF TRUE NORTH
VIEW KEY
LINE TYPE AND TAG KEY:
NEW WORK BY THIS CONTRACTOR (WIDE LINE)
NEW
EXISTING TO BE REMOVED (SHORT DASHED PATTERN)
NEW UNDERFLOOR OR UNDERGROUND (LONG DASHED PATTERN)
EXISTING TO REMAIN OR WORK BY OTHERS (NARROW LINE)
EXISTING
EXISTING TO BE REMOVED BY OTHERS (SHORT DASHED PATTERN)
EXISTING UNDERFLOOR OR UNDERGROUND (LONG DASHED PATTERN)
HALFTONING DOES NOT MODIFY SCOPE.
'TAG'-E TAGS WITH DASH 'E' INDICATES THE REFERENCED OBJECT IS EXISTING
TAG-1 UNDERLINED TAG INDICATES OBJECT IS IN-SCOPE. IF NEW, ADDITIONAL
INFORMATION IS AVAILABLE IN A SCHEDULE, MATERIAL LIST, OR SYMBOL LIST
INDICATES AN EXISTING SYSTEM'S POINT OF CONNECTION/REMOVAL
T101
TEMPERATURE CONTROLS CONTRACTORT.C.C.
ASBESTOS ABATEMENT CONTRACTOR
FIRE PROTECTION CONTRACTORF.P.C.
PLUMBING CONTRACTORP.C.
GENERAL CONTRACTORG.C.
MECHANICAL CONTRACTORM.C.
VENTILATION CONTRACTORV.C.
ELECTRICAL CONTRACTORE.C.
A.C.
CONTRACTOR ABBREVIATION KEY
ABBR: DESCRIPTION:
TECHNOLOGY CONTRACTORT.C.
CONSTRUCTION MANAGERC.M.
M
A X
20" MAX.
M
A X
20"-25" MAX.
M
A X
M
IN
. 4
M
A X
M
A X
10" MAX. 10"-24" MAX.
ADA GUIDELINES - FRONT ACCESS
ADA STANDARDS FOR ACCESSIBLE DESIGN
INSTALL ABOVE COUNTER
DEVICE AT 44" ABOVE
FINISHED FLOOR.
INSTALL ABOVE COUNTER
DEVICE AT 40" ABOVE
FINISHED FLOOR.
INSTALL DEVICE AT 18"
ABOVE FINISHED FLOOR.
ADA GUIDELINES - SIDE ACCESS
INSTALL DEVICE AT 44"
ABOVE FINISHED FLOOR.
INSTALL DEVICE AT 42"
ABOVE FINISHED FLOOR.
1. THE DRAWINGS INDICATE EXISTING ITEMS TO BE REMOVED. THE DRAWINGS ARE
INTENDED TO INDICATE THE SCOPE OF WORK REQUIRED AND DO NOT INDICATE EVERY
BOX, CONDUIT, OR WIRE THAT MUST BE REMOVED. THE CONTRACTOR SHALL VISIT THE
SITE PRIOR TO SUBMITTING A BID AND VERIFY EXISTING CONDITIONS.
2. ITEMS (i.e. SPEAKERS, SWITCHES, ETC.) REMOVED AND NOT RELOCATED REMAIN THE
PROPERTY OF THE OWNER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE
DISPOSAL OF MATERIAL THE OWNER DOES NOT WANT TO REUSE OR RETAIN. (i.e., FOR
MAINTENANCE PURPOSES).
3. EXISTING TO REMAIN DEVICES WITHIN OR ADJACENT TO THE PATH OF CONSTRUCTION
SHALL BE PROTECTED IN PLACE. DEVICES THAT MUST BE REMOVED SHALL BE TESTED
PRIOR TO REMOVAL, PROTECTED FROM DAMAGE, AND RE-INSTALLED IN ITS ORIGINAL
LOCATION DURING THE NEW CONSTRUCTION PHASE OF THE PROJECT.
4. OBTAIN APPROVAL FROM THE OWNER BEFORE TURNING OFF THE POWER TO
EQUIPMENT, SYSTEMS, PANELS, ETC. COORDINATE ALL OUTAGES WITH OWNER.
CONDUIT CONCEALED IN WALL CONSTRUCTION MAY BE ABANDONED IN PLACE IF NOT
AFFECTED BY OTHER CONSTRUCTION.
5. ALL CONDUIT SHALL BE REMOVED WHERE WALLS ARE BEING REMOVED. WHERE
CONDUIT IS IN THE CONCRETE SLAB, CUT OFF FLUSH, PULL OUT WIRE, AND PLUG.
WHERE CONDUIT IS RUN EXPOSED, ALL ASSOCIATED CLAMPS, SUPPORTS, HANGERS,
ETC., SHALL ALSO BE REMOVED.
6. COORDINATE ALL WORK WITH OTHER CONTRACTORS AT THE JOB SITE BEFORE
REMOVING EXISTING EQUIPMENT AND INSTALLING NEW ITEMS.
7. EXISTING CONDUIT IN GOOD CONDITION, MAY BE REUSED IN PLACE. RELOCATING
EXISTING CONDUIT SHALL NOT BE ALLOWED. BONDING CONDUCTORS SHALL BE
INSTALLED IN ALL REUSED CONDUIT TO ASSURE PROPER GROUND PATH.
8. EQUIPMENT REMOVAL IN CERTAIN LOCATIONS MAY REQUIRE THE INSTALLATION OF A
JUNCTION BOX TO RECONNECT CIRCUITS THAT REMAIN IN OPERATION. EXTEND
CONDUIT AND WIRING AS REQUIRED TO MAINTAIN POWER TO REMAINING EQUIPMENT.
9. DEVICES TO BE REMOVED SHALL HAVE ALL CONNECTED WIRING REMOVED TO THE
SOURCE.
10. DEVICES NOT TO BE REMOVED SHALL BE PROTECTED FROM THE ENVIRONMENT, AND
ALL ASSOCIATED CABLE/RACEWAYS ARE TO REMAIN AND BE PROTECTED. T.C. SHALL BE
RESPONSIBLE FOR REPAIR OF ANY INTERRUPTIONS TO PROTECTED DEVICES.
11. CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL OF ALL CEILING TILES WHERE
THEIR RESPECTIVE WORK IS REQUIRED FOR ACCESS ABOVE THE CEILING. DAMAGED
CEILING TILES SHALL BE REPLACED WITH NEW TILES MATCHING THE EXISTING
CONDITIONS. THE CONTRACTOR SHALL DOCUMENT ANY TILES THAT ARE PRE-DAMAGED
PRIOR TO WORK AND SUBMIT EXISTING CONDITIONS TO THE CONTRACTIING AGENT FOR
RECORDS.
12. ALL ABANDONED EQUIPMENT IN THE TELECOMMUNICATION ROOMS BEING ABANDONED
OR TURNED OVER TO THE VA SHALL BE REMOVED AS PART OF THE CONTRACTORS
SCOPE. THIS INCLUDES BUT NOT LIMITED TO RACKS, CABINETS, PATCH PANEL, VOICE
WALLFIELDS AND BONDING SYSTEMS. COORDINATE WITH OWNER PRIOR TO REMOVAL.
13. CONTRACTOR IS TO REMOVE ALL REPLACED CABLING IN ITS ENTIRETLY TO THE TR. NO
CABLING SHALL BE ABANDONED IN PLACE
TECHNOLOGY DEMOLITION NOTES
1. THE EXISTING DATA NETWORK IS TO REMAIN OPERATIONAL DURING THE INSTALLATION
OF THE NEW TELECOM ROOM EQUIPMENT. THE SYSTEM SHALL NOT BE DISRUPTED
UNLESS COORDINATED IN ADVANCE WITH THE OWNER AND ENGINEER AND AT THEIR
DISCRETION ON DATE AND TIME.
2. REFER TO THE DRAWINGS FOR THE LOCATIONS OF THE NEW TELECOM ROOM
EQUIPMENT AND THE EXISTING TELECOM ROOM EQUIPMENT LOCATIONS.
3. CONSTRUCT NEW TELECOMMUNICATIONS ROOMS AND/OR EXPAND EXISTING TO
REMAIN TELECOMMUNICATIONS ROOMS. RENOVATION AND CONSTRUCTION OF
NEW TELECOMMUNICATION ROOMS SHALL BE COMPLETED AT THE START OF THE
PROJECT.
4. MAINTAIN THE EXISTING FIBER AND FEEDS TO THE EXISTING TELECOMMUNICATIONS
ROOM AS CURRENTLY CONSTRUCTED UNTIL THE END OF THE PROJECT.
5. ROUTE NEW FIBER TO THE NEW TELECOMMUNICATIONS ROOMS. MAINTAIN THE
EXISTING ROOMS AND FIBER BACKBONE CABLING UNTIL THE AREA BEING SERVED BY
EACH RESPECTIVE TELECOMMUNICATIONS ROOM HAS BEEN RE-FED.
6. PROVIDE NEW A/B POWER PANELS, HVAC, AND GROUNDING IN NEW AND EXISTING
TO REMAIN ROOMS. POWER ALL TELECOMMUNICATIONS ROOM LOADS FROM THE NEW
PANELS.
7. FOR NEW OR EXPANDED TELECOMMUNICATIONS ROOMS, PROVIDE NEW CABLES FROM
THE EXISTING OUTLETS TO THE NEW ROOMS. REMOVE ALL EXISTING CABLING AFTER
NEW CABLES HAVE BEEN PULLED TO THE OUTLETS TO MAINTAIN THE OPERATIONAL
CAPABILITY OF THE SPACES TO THE GREATEST EXTENT POSSIBLE.
8. AFTER NEW CABLING HAS BEEN INSTALLED, REMOVE EXISTING BACKBONE CABLING
IN TELECOMMUNICATIONS ROOMS BEING ABANDONED.
9. REFER TO THE TECHNOLOGY DEMOLITION NOTES FOR ADDITIONAL REQUIREMENTS.
PHASE 1 - PATHWAYS AND INFRASTRUCTURE
A. INSTALL NEW INTER-BUILDING UNDERGROUND DUCT BANK CONDUITS.
B. BUILD OUT NEW TR SPACES.
C. INSTALL NEW INTRA-BUILDING BACKBONE CABLING PATHWAYS.
PHASE 2 - BACKBONE CABLING
A. INSTALL INTER-BUILDING BACKBONE CABLING.
B. INSTALL INTRA-BUILDING BACKBONE CABLING.
C. TERMINATE AND TEST.
PHASE 3 - HORIZONTAL CABLING
A. INSTALL NEW CAT 6A CABLING.
• TERMINATE CABLING IN NEW TR PATCH PANELS.
• NEATLY COIL CABLING AT EXISTING OR EXPANDED TR LOCATIONS FOR CUTOVER
TO NEW RACKS AND PATCH PANELS.
B. NEATLY COIL CABLING AT EXISTING OUTLET LOCATIONS.
PHASE 4 - CUTOVER
A. OIT INSTALLATION OF NETWORK SWITCHES AT EACH TR PLANNED FOR CUTOVER .
PHASING FOR THE NUMBER OF CLOSET TO BE CONCURRENTLY WORKED ON SHALL
BE BASED ON A QUANTITY OF (10) 48-PORT NETWORK SWITCHES AVAILABLE BY THE
VA OIT.
B. REMOVE EXISTING OUTLET CABLING FROM OUTLET AND ROUTE NEW CAT 6A
CABLING INTO OUTLET.
• NEATLY COIL EXISTING CABLING ABOVE CEILING.
C. REMOVE EXISTING EQUIPMENT RACKS AND INSTALL NEW EQUIPMENT RACKS
EQUIPMENT IN REMODELED OR EXPANDED TR.
D. TERMINATE AND TEST NEW CABLING.
E. OIT CUTOVER AND PATCHING TO NETWORK SWITCHES.
PHASE 5 - DEMOLITION
A. REMOVE OLD FIBER OPTIC BACKBONE CABLING FROM EACH OLD TR FOLLOWING
SUCCESSFULL CUTOVER TO NEW TR.
• OTHER EXISTING SYSTEMS IN OLD TR TO REMAIN FUNCTIONAL.
B. REMOVE OLD HORIZONTAL CABLING FROM EACH OUTLET BACK TO ITS SOURCE
FOLLOWING SUCCESSFUL CUTOVER.
C. REMOVE ALL EQUIPMENT RACKS AND ASSOCIATED EQUIPMENT FROM EACH OLD TR
FOLLOWING SUCCESSFUL CUTOVER.
10. REFER TO THE DIV 01 SPECIFICATIONS FOR ADDITIONAL INFORMATION ON PHASING
TECHNOLOGY PHASING NOTES
FIRE WALL/PARTITION NOTES:
1. REFER TO THE PHASING PLAN FOR THE LOCATIONS OF FIRE RATED WALLS TO ENSURE
PROPER FIRESTOPPING AND WALL REPAIRS.
SUGGESTED MATRIX OF RESPONSIBILITY
ITEM: SHOWN ON:
FURNISHED
BY:
INSTALLED
BY: NOTES:
TECHNOLOGY ROUGH-IN, REFER TO
TECHNOLOGY EQUIPMENT SCHEDULE
AND SPECIFICATIONS FOR DEFINITION
T-SERIES E.C. E.C. 3. 4.
INFORMATION OUTLET FACEPLATES,
JACKS, AND TERMINATIONS
T-SERIES T.C. T.C.
CONDUIT SLEEVES (WHEN SHOWN ON
DRAWINGS)
T-SERIES E.C. E.C.
CONDUIT SLEEVES (NOT SHOWN BUT
REQUIRED FOR PROPER INSTALLATION
OF SYSTEM)
N/A T.C. T.C. 2. 4.
TELECOMMUNICATION SYSTEMS
ROUGH-IN
T-SERIES E.C. E.C. 1.
TELECOMMUNICATION EQUIPMENT,
CABLING, AND TERMINATIONS
T-SERIES T.C. T.C.
CABLE TRAY (INCLUDING WIRE BASKET
TRAY)
T-SERIES E.C. E.C.
LADDER RACK T-SERIES T.C. T.C. 5.
GROUNDING LUGS ON TECHNOLOGY
EQUIPMENT
T-SERIES T.C. E.C. 6.
BONDING SYSTEM FOR TECHNOLOGY
SYSTEM
T-SERIES E.C. E.C. 7. 8.
CONNECTION OF TECHNOLOGY
BONDING SYSTEM TO THE ELECTRICAL
GROUND SYSTEM
T-SERIES E.C. E.C.
LINE VOLTAGE POWER (+120V OR
GREATER)
E-SERIES E.C. E.C.
LINE VOLTAGE POWER (NOT SHOWN
BUT REQUIRED FOR PROPER
INSTALLATION OF SYSTEM)
N/A T.C. E.C. 2. 4.
LINE VOLTAGE POWER FOR DOOR
HARDWARE POWER SUPPLIES
ARCH SPEC E.C. E.C.
LOW VOLTAGE CABLING FOR
TECHNOLOGY SYSTEMS
T-SERIES T.C. T.C.
CABLE HANGERS AND SUPPORTS OR
OTHER CABLE ROUTING METHODS
(OTHER THAN CONDUIT AND CABLE
TRAY)
T-SERIES T.C. T.C. 5.
FLOOR BOX (ROUGH-IN) T & E SERIES E.C. E.C.
SUGGESTED MATRIX OF RESPONSIBILITY NOTES
1. LOCATIONS OF TELECOMMUNICATIONS ROUGH-INS SHALL BE INDICATED BY THE INFORMATION
OUTLET SYMBOLS ON THE DRAWINGS. REFER TO THE TECHNOLOGY SYMBOL LIST FOR
ADDITIONAL INFORMATION.
2. BASED ON THE INHERENT DIFFERENCES IN PRODUCTS FROM VARIOUS MANUFACTURERS, ALL
REQUIRED EQUIPMENT MAY NOT BE SHOWN ON THE DRAWINGS FOR ALL ACCEPTABLE
MANUFACTURERS.
3. INCLUDES BACKBOXES AND CONDUIT REQUIRED FOR THE TECHNOLOGY SYSTEMS
INSTALLATION. THE E.C. SHALL BASE THE BID ON THE BASIS OF DESIGN SHOWN ON THE
CONTRACT DOCUMENTS.
4. ALL CHANGES TO THE SLEEVES, BACKBOXES, CONDUITS, AND POWER REQUIRED BECAUSE OF
THE T.C.'S SELECTION OF AN ALTERNATE ACCEPTABLE MANUFACTURER OR FROM SYSTEM
CONFIGURATIONS THAT ARE LEFT TO THE CHOICE OF THE CONTRACTOR SHALL BE INCLUDED
IN THE T.C.'S BID. THIS BID SHALL INCLUDE INSTALLATION BY A LICENSED ELECTRICIAN.
5. UNLESS TRADE RULES DICTATE OTHERWISE.
6. FURNISHED AS PART OF THE EQUIPMENT WHEN POSSIBLE, OR FURNISHED TO THE E.C. FOR
INSTALLATION IN THE FIELD.
7. INCLUDES ALL CONDUCTORS, GROUND BARS, AND TERMINATIONS FOR THE COMPLETE
BONDING SYSTEM REQUIRED BY THE SPECIFICATIONS.
8. REFER TO ELECTRICAL DRAWINGS FOR LOCATIONS OF PANELS AND SWITCHBOARDS SHOWN
IN THE TECHNOLOGY BONDING RISER DIAGRAM AND TYPICAL TELECOM ROOM BONDING FLOW
DIAGRAM.
263 SHUMAN BOULEVARD
SUITE 550
NAPERVILLE, IL 60563
P: 630.527.2320
The FUTURE. Built Smarter www.imegcorp.com
PROJECT #21006425.00
13100 watertown plank road, suite 200 elm grove, wi 53122
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
NAGEL
project number:
B
IM
/2
.0
V
A -C h ic a g o
IL
-J
B E
H R
M /5
-7
.J
B E
H R
M .M
E P
T
C .r v t
/1
/2
:1 :4
A
M
00-T000
TECHNOLOGY - LEGENDS, NOTES JESSE BROWN VAMC EHRM
INFRASTRUCTURE UPGRADES
820 S DAMEN AVE, CHICAGO, IL 60612
537-21-700
VA BLDG
18 AUG 2025 MARWIT ALFARA
ISSUED FOR BID &
CONSTRUCTION
21011
LEGEND NOTES
TELECOM ROOM REFERENCES "TR"
TELECOM ROOM
DETAIL / SHEET
REFERENCE
FLOOR PLAN
REFERENCE ARCH ROOM NUMBER
BIOMED SERVER ROOM 1/1AS-TN307 00-TN107 7433
EXISTING TR 11T1 N/A 00-TN101 11T1
EXISTING TR 12T1 N/A 00-TN101 12T1
EXISTING TR 12T2 N/A 00-TN101 12T2
EXISTING TR 13T1 N/A 00-TN101 1362
EXISTING TR 14T2 N/A 00-TN101 14T2
EXISTING TR 14T3 N/A 00-TN101 14T3
EXISTING TR 14T4 N/A 00-TN101 14T4
EXISTING TR 15T1 N/A 00-TN101 15T1
EXISTING TR 22T1 N/A 00-TN102 22T1
EXISTING TR 22T2 N/A 00-TN102 22T2
EXISTING TR 24T1 N/A 00-TN102 24T1
EXISTING TR 32T1 N/A 00-TN103 32T1
EXISTING TR 32T2 N/A 00-TN103 32T2
EXISTING TR 34T1 N/A 00-TN103 34T1
EXISTING TR 35T1 N/A 00-TN103 35T1
EXISTING TR 42T1 N/A 00-TN104 42T1
EXISTING TR 42T2 N/A 00-TN104 42T2
EXISTING TR 44T1 N/A 00-TN104 44T1
EXISTING TR 45T1 N/A 00-TN104 45T1
EXISTING TR 52T1 N/A 00-TN105 52T1
EXISTING TR 52T2 N/A 00-TN105 52T2
EXISTING TR 54T1 N/A 00-TN105 54T1
EXISTING TR 55T1 N/A 00-TN105 55T1
EXISTING TR 62T1 N/A 00-TN106 62T1
EXISTING TR 62T2 N/A 00-TN106 62T2
EXISTING TR 64T1 N/A 00-TN106 64T1
EXISTING TR 72T1 N/A 00-TN107 72T1
EXISTING TR 72T2 N/A 00-TN107 72T2
EXISTING TR 74T1 N/A 00-TN107 74T1
EXISTING TR 84T1 N/A 00-TN108 84T1
EXISTING TR 94T1 N/A 00-TN109 94T1
EXISTING TR 104T1 N/A 00-TN110 104T1
EXISTING TR 1539F N/A 00-TN101 1538F
EXISTING TR 2330 N/A 00-TN102 2330
EXISTING TR 3362 N/A 00-TN103 3362
EXISTING TR 4634 N/A 00-TN104 4634
EXISTING TR 5362 N/A 00-TN105 5362
EXISTING TR 6362 N/A 00-TN106 6362
SERVER ROOM 1/1AS-TN306 00-TN107 7467
TR1A-1 1/1AS-TN300 00-TN101 TR1A-1
TR1A-2 4/1AS-TN300 00-TN102 TR1A-2
TR1A-3 1/1AS-TN301 00-TN103 TR1A-3
TR1A-4 4/1AS-TN301 00-TN104 TR1A-4
TR1A-5 1/1AS-TN302 00-TN105 TR1A-5
TR1A-6 4/1AS-TN302 00-TN106 TR1A-6
TR1A-7 1/1AS-TN303 00-TN107 TR1A-7
TR1A-8 4/1AS-TN303 00-TN108 TR1A-8
TR1A-9 1/1AS-TN304 00-TN109 TR1A-9
TR1A-10 4/1AS-TN304 00-TN110 TR1A-10
TR1AA-1 1/1A-TN305 00-TN101 TR1AA-1
TR1B-1 1/1B-TN300 00-TN101 TR1B-1
TR1B-2 4/1B-TN300 00-TN102 TR 1B-2
TR1B-3 1/1B-TN301 00-TN103 TR1B-3
TR1B-4 4/1B-TN301 00-TN104 TR1B-4
TR1B-5 1/1B-TN303 00-TN105 TR1B-5
TR11A-1A 1/11A-TN300 00-TN101 TR11A-1A
TR11A-2 4/11A-TN300 00-TN102 TR11A-2
TR11A-3 1/11A-TN301 00-TN103 TR11A-3
TR11A-4 4/11A-TN301 00-TN104 TR11A-4
TR11A-5 1/11A-TN302 00-TN105 TR11A-5
TR11A-6 4/11A-TN302 00-TN106 TR11A-6
TR11A-7 1/11A-TN303 00-TN107 TR11A-7
TR11B-1 1/11B-TN301 00-TN101 TR11B-1
TR11B-2 4/11B-TN301 00-TN102 TR11B-2
TR11B-3 1/11B-TN302 00-TN103 TR11B-3
TR11B-4 4/11B-TN302 00-TN104 TR11B-4
TR11B-5 1/11B-TN303 00-TN105 TR11B-5
TR11B-6 4/11B-TN303 00-TN106 TR11B-6
TR11B-7 1/11B-TN304 00-TN107 TR11B-7
TR30-1 1/30-TN301 00-TN101 TR30-1
TR32-1 1/32-TN301 00-TN101 TR32-1
TR40-1 1/40B-TN300 00-TN101 40-1
TR40-2 1/40B-TN301 00-TN102 40-2
TR40-3 4/40B-TN301 00-TN103 40-3
TR40-4 1/40B-TN302 00-TN104 40-4
TR40-5 4/40B-TN302 00-TN105 40-5
TR40-6 6/40B-TN302 00-TN106 40-6
TR40-7 1/40B-TN303 00-TN107 40-7
Revisions: Date:
Ryan Bourland Text Box
12 MAR 2025,
18 AUG 2025 R1
S
S S
S SS S S S S S
P PP P P P P P
P P P
P P
P P
P P
P P
P P
P P
S SS S S S S S SS
S
S S
S S
S S
S S
S S
S S
S S
S S
S P
P
P PP P P P P P
P P
P P
P P
P P
P PP P
P P
P P
SSS
S
P P
P PP P P P P P P P P P
P P
P P P
P P
P P
P
P P
P P
P
P PP P
P PP P P P P P P P P P P PP
P
P
S SS S S S S S S S S S S
S S
TR 1AA
1AA-1
TR11B
11B-1
TR11B
VESTIBULE
11B-1B
TR32
32-1
TR30
30-1
CONFERENCE
LUNCH RM
LOCKERS
1264A
STAFF
TOILET
CLEAN
STORAGE
(DRY)
CLEAN
STORAGE
(WET)
WAREHOUSE
MAIL ROOM
SHAFT
NURSE MGR
SOCIAL
WORKER
CHAIR
STATION
CUBICLES
CLEAN
STORAGE
ALCOVE
1266A
CHAIR
STATION
CUBICLES
1259A
CORRIDOR
TEMPORARY
NURSES
STATION
TEMPORARY
SOILED
UTILITY
PATIENT
TOILET
CHIEF
PHYSICIAN
IRM
12T1MECH ROOM
MAIN
ENTRANCE
WATER
TREATMENT
STORAGE
PATIENT
WAITING
AREA
WHEELCHAIR
STORAGE
1249A
BIO-MED
REPAIR
IRM
STORAGE
MECH
FAC
ELECTRICAL
12E2
TELEPHONE
CANTEEN
STORAGE
REFR
REFR
STORAGE
1210B
CONFERENCE
RM
OFFICE
STAFF
OFFICE
STAFF
OFFICE
STAFF
OFFICE
OUTPATIENT
PHARMACY
NARCOTIC
VAULT
TOILET
STORAGE
1213A
CORRIDOR
C1203
STORAGE
DISH
WASHING
HAC
CANTEEN
STORAGE
CORRIDOR
C1204
CORRIDOR
C1205
LOADING
DOCK
1280A
VESTIBULE
1275A
OFFICE
ELECTRICAL
ELECTRICAL
LOUNGE
HAC
SUPERVISOR
OFFICE
TELECOM
12T2
PHARMACY
CONSULTATION
1195A
CORRIDOR
C1115
OFFICE
CONSULT
OFFICE
DIETICIAN
OFFICE
SUPV CLINIC
SUPPORT
OFFICE
STORAGE/
COPIER
DERMLITE
RM
RN OFFICE
1200A
BEHAVIORAL
HEALTH LAB
1200B
DERMATOLOGY
EXAM ROOM
URGENT
CARE EXAM
1182A
URGENT
CARE EXAM
1182B
URGENT
CARE EXAM
1162A
STORAGE
OFFICE
OFFICE
102A
CORRIDOR
MEN'S
TOILET
WOMEN'S
TOILET
PROGRAM
ROOM
1T15
CORRIDOR
PAINT
STORAGE
CARPENTRY
STORAGE
ELECTRICAL
STORAGE
PLUMBING
STORAGE
HVAC
STORAGE
EXERCISE
AREA
RESIDENT
TEAM
1225A ELECTRICAL
1210C
CORRIDOR
C1207
CHIEF
1238 COPIER/STORAGE
PHARMACY/OFFICE
STAFF
OFFICE
MANAGER
PROCUREMENT
PHARMACIST
OFFICE
EMS HAC
STORAGE
FEMALE
TOILET
MALE TOILET
CORRIDOR
C1203
CORRIDOR
C1206
FAC
1210ASTAIR
STAIR
ELEVATOR
P1A
ELEVATOR
P2A
ELEVATOR
S3A
ELEVATOR
FUTURE
P4A
ELEVATOR
5A
STAIR
KITCHEN
KITCHEN
COOKING
AREA
FOOD SVC
VENDING
CANTEEN
DINING AREA
CORRIDOR
1294A
DERMATOLOGY
EXAM RM
DERMATOLOGY
EXAM RM
DERMATOLOGY
EXAM RM
DERMATOLOGY
EXAM RM
DERMATOLOGY
EXAM RM
EXAM RM
EXAM RM
EXAM RM
EXAM RM
EXAM RM
1181B
EXAM RM
1189A
EXAM RM
URGENT
CARE
CONSULTATION
RM
CORRIDOR
C1112
CORRIDOR
C1111
EXAM RM
URGENT
CARE
EXAM RM
GREEN
CLINIC
1170ELECTRICAL
11E3
EXAM RM
GREEN
CLINIC
EXAM RM
EXAM RM
EXAM RM
GREEN
CLINIC
EXAM RM
EXAM RM
WOMEN'S
TOILET
MEN'S
TOILET
NURSE
OFFICE
NURSE
OFFICE
MEN'S
TOILET
WOMEN'S
TOILET
EXAM RM
ELECTRICAL
11E2
EXAM RM
EXAM RM
EXAM RM
EXAM RM
EXAM RM
EXAM RM
CONSULTATION
RM
CORRIDOR
C1110
CORRIDOR
C1109
CORRIDOR
C1107
CORRIDOR
C1106
CORRIDOR
C1108
CASHIER
STORAGE
AGENT
CASHIER
NURSE
OFFICE
NURSE
OFFICE
NURSE
OFFICE
DERMATOLOGY
EXAM RM
ELECTRICAL
11E4
PHARMACY
STAFF
1195B
CLINIC
BREAK RM
EXAM RM
EXAM RM
1161B
EXAM RM
1161A
EXAM RM
EXAM RM
EXAM RM
EXAM RM
EXAM RM
UROLOGY
NURSE
OFFICE
NURSE
OFFICE
EXAM/
SCREENING
EXAM/
SCREENING
EXAM/
SCREENING
ELECTRICAL
11E1
UROLOGY
EXAM RM
EXAM/
SCREENING
GU CLINIC
EXAM RM
EXAM/
SCREENING
GU CLINIC
EXAM RM
C1120
CONSULTATION
RM
URGENT
MAINT
VACANT
TOILET
1139A
URODYNAMIC/
ULTRASOUND
UROLOGY
TREATMENT
PROCEDURE
EXAM/
SCREENING
UROLOGY
OFFICE
HAC
TOILET
CLEAN
SUPPLY
ELECTRICAL
TOILET
DIRTY
UTILITIES
STERILE RM
MINOR OR
SURGY RM
GU CLINIC
EXAM RM
PHARMACIST
EXAM RM
NURSE
OFFICE
TELECOM
11T1
TOILET
DRESSING
RM
LOCKER
CORRIDOR
C1105
RECOVERY
RM
SUPPLY RM
UROLOGY
OFFICE
CLINICS
WOMEN'S
TOILET
MEN'S
TOILET
FLAMABLE
STORAGE
RADIOACTIVE
STORAGE
GENERATOR
RM
1300A
CORRIDOR
CANTEEN
CORRIDOR
C1202
CORRIDOR
C1201
STAIR
OFFICE
1302A
TRANSFORMER
RM
CHIEF
OFFICE
STORAGE
ELEVATOR
P-7B
FUTURE
ELEVATOR
P-6B
ELEVATOR
P-8B
ELEVATOR
P-9B
RESTROOM
ELEVATOR
S-10B
STAIR
TEL PHONE
DATA RM
13T1
TOILET
1345B
CLERICAL
SUPPORT
WAITING
CORRIDOR
INTAKE
NURSE
EXAM RM
EXAM RM
PROC
EXAM RM
EXAM RM
PROC
EXAM RM
ACCESIBLE
STAFF
TOILET
EXAM RM
CORRIDOR
PHYSICIAN
OFFICE
STAIRCASE
STORAGE
ELECTRICAL
CLOSET
FIRE CLOSET
CORRIDOR
SOILED
UTILITY RM
ELECTRICAL
CORRIDOR
C1305
CORRIDOR
C1303
CORRIDOR
C1304
CORRIDOR
C1306
CORRIDOR
C1301
MRI SUITE
STAGING
1345F
HOLDING
1345E
VIEW
1345C
IMAGING
SUPV OFFICE
1345A
OFFICE
MOHS LAB
PHOTO
THERAPY
EQUIP
CLOSET
1345J
MRI EQUIP
1390D
MRI GANTRY
RM
1345I
MALE REST
RM
REST RM
REST RM
STORAGE
HAC
WOMEN'S
TOILET
ELECTRICAL
ELECT.
CORRIDOR
C1302
HAC
PHONE
CLOSET
CORRIDOR
PATHOLOGY
LAB
OUTPATIENT
SPECIMEN
LAB
WAITING RM
SUPV BLOOD
DRAW
OFFICE
1363A
PATH
SUPPLY
1363B
MULTI
PURPOSE
RM
MED CENTER
SAFETY
OFFICER
OFFICE
1363C
OUTPATIENT
RADIOLOGY
WAITING
AREA
REST RM
CONTROL
RM
1379A
ELECTRICAL
STORAGE
STORAGE
STORAGE
STORAGE
1390B
STORAGE
1390C
STAIR
OUTPATIENT
RADIOLOGY
EXAM/TREATMENT
READING RM
COMPUTER
ASST /
ADPAC RPA
OFFICE
DRESSING
RM
DRESSING
RM
OUTPATIENT
RADIOLOGY
EXAM/TREATMENT
CORRIDOR
1376A
DRESS
1345D
SUPPORT
ALCOVE
1345H
CONTROL
RM
1345G
CORRIDOR
C1608
CORRIDOR
C1202B
ENTRANCE
C1101
CORRIDOR
C1102
MEN'S
TOILET
WOMEN'S
TOILET
HEALTH VET
CO-ORDR
CREDIT
UNION
WAITING RM
ELECTRICAL
PHYSICIAN
ASSIST
TRIAGE
TRIAGE
STORAGE
FIRE
CONTROL
PATIENT
ADVOCATE
OFFICE
OPTICAL
WAITING RM
1410B
OPTICAL
DISPENSARY
1410A
ELECTRICAL
SWITCH RM
STAIR
TRIAGE
RECEPTION
AND
ADMISSION
AMBULATORY
CARE SUPV
OFFICE
CHIEF
AMBULATORY
TRAVEL
OFFICE
VTS
MANAGER
ER HALLWAY
1431 MEDICAL
SUPPORT
1431C
ER STORAGE
1431B
TRIAGE
ICE MACH
E D
ATTENDING
TRIAGE
EMS
STORAGE
1431A
TELEPHONE
TRIAGE
NEGATIVE
PRESSURE
TOILET
CLEAN LINEN
EMS
TOILET
CLEAN
SUPPLY
AMBULANCE
DROP-OFF
VESTIBULE
C1408
CORRIDOR
C1407
HAC
CONSULT RM
PAC
CO-ORDR
CHIEF
CONSULT RM
CONSULT RM
CONSULT RM
CONSULT RM
CONSULT RM
ADDICTION
RECEPTION
VIST
CO-ORDR
ER OFFICE
TOILET
EXAM RM
1470A
VEST/STAIR
2B
CORRIDOR
C1445
CORRIDOR
C1406
ELECTRICAL
ER MGR
VESTIBULE
C1116
ER OFFICE
1459A
STAIR
CORRIDOR
C1409
ELEVATOR
P7
ELEVATOR
P8
ELEVATOR
P1
ELEVATOR
P2
ELEVATOR
P3
ELEVATOR
P4
ELEVATOR
S5
ELEVATOR
S6
TR1A
1A-1
EQUIP
STORAGE
CORRIDOR
C1404
CORRIDOR
C1402
ROOM
STAIR
5A
NURSE
STATION
EMERGENCY
RM
EXAM RM
1470B
EXAM RM
1470C
EXAM RM
1470D
EXAM RM
1470E
EXAM RM
1470F
EXAM RM
1470G
MEDS
1470H
EXAM RM
1470J
EXAM RM 9
1470KEXAM RM 10
1470L
ON CALL
1491B
EXAM RM 11
1470M
EXAM RM 12
1470N
SOILED
UTILITY
EXAM RM 13
1470P
EXAM RM 14
1470Q
EXAM RM
1470R
ELECTRICAL
14E6
COMM
14T3
OFFICE
1475A
LOUNGE
ELECTRICAL
CLOSET
14E4
TOILET
1491A
WAITING RM
LOGISTICS
AREA
MECH RM
OFFICE
TOILET
1472B
ON CALL
SECRET
OFFICE
MEN'S
TOILET
1473 DOCTOR
OFFICE
TELECOMMUNICATION
STAFF
OFFICE
ELEVATOR
FOYER
ELEVATOR
MECH
STAIR
GAS
STORAGE
1503 TELECOMMUNICATION
RM
14T4
BIOHAZARD
CONTAINER
CORRIDOR
C1401
PHARMACY
IV STORAGE
DONATED
CLOTHING
STORAGE
MORGUE
ELEVATOR
EMS LINEN
RM
EMS
STORAGE
FIRE HOSE
CONTROL
RM
1528B
FIRE ALARM
WAITING RM
CLEAN
SUPPLY
TOILET
1530B
CONSULT RM
TECH WORK
HAC
CONSULT RM
TOILET
GOWNED
WAITING
CONTROL
RM
1530A
CT IMAGING
RM
TOILET
1528A
CLEAN
GAS
CYLINDER
STORAGE
MEN'S
CHANGING
WOMEN'S
CHANGING
CORRIDOR
C1503
CORRIDOR
C1501
CORRIDOR
C1502
CORRIDOR
C1505B
CORRIDOR
C1405
CORRIDOR
C1504
ELECTRICAL
1541B
SECY OFFICE
INPT
HOLDING
CT IMAGING
RM
DIGITAL
RADIOLOGY
CORRIDDOR
C1506
RADIOLOGY /
FLUOROSCOPIC
RM
READING RM
ELECTRICAL
15E4
DIGITAL
RADIOLOGY
ULTRASOUND
PREP/
RECOVERY
RADIOLOGY
SUPPLY
1539 I R READING
RM
1539A
ANTE RM
1538B
CONTROL
RM
1538D
SPECIAL
PROCEDURES
INTERVENTIONAL
1538C
EQUIP RM
1538E
COMMUNICATIONS
1538F
STAIR
TOILET
1538A
CORRIDOR
C1506A
TOILET
1533A
MECH
SWITCHGEAR
RM
STAIRWELL
C1506B
VESTIBULE
1570A
ATS RM
1570C
ELECTRICAL
RM
HAC
TELEPHONE
CLOSET
15T1
SPD SUPV
OFFICE
ELECTRICAL
CLOSET
15E2
SPD
RECEIVING
STORAGE
CHIEF
RADIOLOGY
SECY OFFICE
RADIOLOGY
SVC
OPERATION
MGR
RADIOLOGY
SVC
CONFERENCE
RM
STORAGE
COMPUTER
CABINET
1581A
FAN RM
VESTIBULE
C1507
CORRIDOR
C1510
STAIR
RADIOLOGY
OFFICE
CORRIDOR
C1509
RADIOLOGY
READING RM
RADIOLOGY
OFFICE
RADIOLOGY
OFFICE
RADIOLOGY
OFFICE
RADIOLOGY
OFFICE
RADIOLOGY
SCHEDULING
RADIOLOGY
SVC
UTRASOUND
CORRIDOR
C1505
TOILET
CORRIDOR
C1505C
CORRIDOR
C1511
EVIDENCE
OFFICE VIEW
VESTIBULE
PHYSICAL
SECURITY
1540A
PHYSICAL
SECURITY
1540B
SQUAD RM
OFFICE
CONFERENCE
/ TRAINING
DEPUTY
CHIEF
POLICE
OPERATION
OPERATION
CAPTAIN
STORAGE
1554B
EVIDENCE
STORAGE
1542A
CLOSET
1544A
HOLD CELL
HOLD CELL
POLICE
INVESTIGATION
OFFICE
POLICE
CHIEF
TOILET
1555B
TEL CLOSET
14T2
TOILET
1499A
VESTIBULE
1499B
STAFF
LOCKER
TOILET
STAFF
LOCKER
TOILET
1628 STAFF
LOUNGE
MANUAL
EQUIP WASH
HAC
16H5
SALLY PORT
1635AELEVATOR
P-26
SACRISTY
SOILED
RECEIVING /
DECONTAM
STEAM
STERILIZER
CART WASH
ETO SVC
ETO RM
1639A
PREPARATION
SECURED
ITEMS
CART
STAGING
AREA
1640A
STERILE
SUPPLY
STORAGE
AND DIST
1640B
VESTIBULE
CHAPEL
VESTIBULE
1602A
SECY
BLESSED
SACRAMENT
ELEVATOR
PIT
P-27
FIRE
COMMAND
CENTER
1608 ELEVATOR
MACH RM
STAIR
ESCORT
WAITING RM
WHEELCHAIR
WASH
CHIEF
CHAPLAIN
CHAPLAIN
OFFICE
VENDING
MACH
ELECTRICAL
RM
16E1A
CORRIDOR
C1607
HAC
16H4
MALE TOILET
WOMEN'S
TOILET
TELEPHONE
ALCOVE
HAC
16H6
TOILET
1643A
SPD STAFF
OFFICE
TOILET
1646A
STAFF
LOCKER
SPD CHIEF
STAFF
LOUNGE
STAFF
LOCKER
DINNING
SPACE
VESTIBULE
1652A
EMS
STORAGE
1652B
HAC
16H2
GAS
CYLINDER
STORAGE
EMS OFFICE
STAIR
WASTE RM
STAFF
LOUNGE
STAFF
TOILET
VESTIBULE
WOMEN
STAFF
LOCKER
LINEN CHUTE
RM
16L1
TR40
40-1
VESTIBULE
MEN STAFF
LOCKER
SHOWER
1662B
TOILET
1662A
PAT TOILET
HOLDING RM
HOLDING RM
HOLDING RM
HOLDING RM
HOLDING RM
HOLDING RM
HOLDING RM
HOLDING RM
HOLDING RM
PAT CLINIC
PAT CLINIC
PAT CLOTH
CLOSET
STORAGE
CLEAN
SUPPLY
PANTRY
PAT TOILET
OFFICE
HOLDING RM
HOLDING RM
SOILED
UTILITY
HOLDING RM
ELEVATOR
OFFICE
PAT TOILET
VESTIBULE
CLEAN
SUPPLY
MINOR
PROCEDURE
MINOR
PROCEDURE
CLEAN LINEN
COMPUTER
TRAINING
SURGY
FAMILY
WAITING
VESTIBULE
BULK
STORAGE
VESTIBULE
1661A
VESTIBULE
1657A
EMS CLEAN
SUPPLY
RECEIVING
16H1
LOBBY
C1606
ELEVATOR
ELEVATOR
ELEVATOR
ELECTRICAL
RM
16E2
ELEVATOR
ELEVATOR
DISCHARGE
LOUNGE
ELEVATOR
REGISTRATION
SURGY
RECEPTION
HAC
16H3
CONSULT RM
1697B
ELEVATOR
MACH RM
1696A
CONSULT RM
1697A
MED RM
1687A
ELEVATOR
STAIR
15 ELEVATOR
LOBBY
C1604
NURSE
STATION
CORRIDOR
C1603
ELEVATOR
LOBBY
C1602
CORRIDOR
C1601
ELEVATOR
LOBBY
C1605
STAIR
ELECTRICAL
RM
16E1B
FIRE PUMP
RM
MECH PUMP
RM
CORRIDOR
C1113
CORRIDOR
C1114
FAC
ELEC
CLOSET
14E5
COPY
VESTIBULE
1521A
CORRIDOR
C1508
RECEPTION
ARMORY RM
CLOSET
1541A
CLOSET
1545A
CORRIDOR
C1411
VESTIBULE
ELECTRICAL
14E7
EXIT
CORRIDOR
1679A
TOOL
STORAGE
TOILET
1472A
ROOM
1479B
ADMIN
OFFICES
1479C
STAIR
OFFICE
1479D
TR1B
1B-1
TR 11A
11A-1AELEC RM
11A-1B
1.1
1.2
1.3
1.5
1.6
1.7
1.10
1.11
1.12
1.13
1.14 1.15
1.20
1.21
1.V1.O1.N1.M
1.4
1.J
1.J
2.4
2.4
2.3
2.3
2.2
2.2
2.1
2.1
2.5
2.6
2.7
2.8
2.10
2.9
X8X8.1
X7
X6.6
X6.5
X9
X10
X11 2.11
X12
2.12
2.13
2.14
2.A
2.C1
X13
2.D
2.C5
2.A5
2.B
2.B
2.C
2.D9 2.G2.F2.E
3.P
3.N
3.M
3.L
3.K
3.J
3.H
3.G
3.F
3.E
3.A
3.B
3.C
3.D
3.1 3.2 3.3 3.5 3.7 3.8 3.9 3.10 3.11 3.12 3.13 3.173.163.153.14
3.18 3.19
3.20 3.21 3.22 3.23 3.24
5.J1
5.N1
5.U
5.S
5.C
5.10 5.12 5.14 5.16 5.19 5.21 5.23
5.25 5.27 5.30 5.32
5.35 5.38 5.435.41
4.4
4.5
4.3
4.2
4.1
4.D54.C54.A 4.B 4.C 4.D 4.E 4.F
5.N
5.G
5.34
5.37 5.40 5.445.44.5 5.49
5.Y
5.BB
1.22
1.H1.G1.F 1.K 1.P 1.Q 1.R
1.19
1.18
1.17
1.16
1.8
1.A 1.B 1.C 1.D 1.E
1.L
3.J1
1.I
V2V1
VB
VA
X1 X2 X3
XB
XA
Y1
1.S 1.T 1.U
1.U2
5.A
Y2
Y3
Y4
EXISTING TR 14T4
(DEMARCATION)
EXISTING
TR 14T3
TR40-1
EXISTING TR 15T1
EXISTING TR 1539F
DAMEN WEST
(BALD. 1B)
EXISTING TR
14T2
ALL LOW VOLTAGE CABLING IN
THIS AREA SHALL BE SERVED
FROM TR1B-1
ALL LOW VOLTAGE CABLING IN
THIS AREA SHALL BE SERVED
FROM TR1B-1
ALL LOW VOLTAGE CABLING IN
THIS AREA SHALL BE SERVED
FROM TR1AA-1
ALL LOW VOLTAGE CABLING IN
THIS AREA SHALL BE SERVED
FROM TR1A-1
TR1B-1
TR1A-1
TR1AA-1
ALL LOW VOLTAGE CABLING IN
THIS AREA SHALL BE SERVED
FROM TR30-1
ALL LOW VOLTAGE CABLING IN
THIS AREA SHALL BE SERVED
FROM TR1A-1
ALL LOW VOLTAGE CABLING IN
THIS AREA SHALL BE SERVED
FROM TR1AA-1
ALL LOW VOLTAGE CABLING IN
THIS AREA SHALL BE SERVED
FROM TR40-1
TR11A-1A
TR32-1
ALL LOW VOLTAGE CABLING
IN THIS AREA SHALL BE
SERVED FROM TR11A-1A
ALL LOW VOLTAGE CABLING
IN THIS AREA SHALL BE
SERVED FROM TR32-1
TR30-1
ALL LOW VOLTAGE CABLING
IN THIS AREA SHALL BE
SERVED FROM TR11B-1
ALL LOW VOLTAGE CABLING
IN THIS AREA SHALL BE
SERVED FROM TR11A-1A
TR11B-1
EXISTING
TR 12T1
EXISTING TR 13T1
OGDEN
EXISTING TR 12T2
ATRIUM
EXISTING TR 11T1
ALL LOW VOLTAGE CABLING IN
THIS AREA SHALL BE SERVED
FROM TR30-1
SECONDARY FIBER ROUTE
WITH (1) 24-STR OM4 AND (1) 12-
ST OS1 TO TR1AA-1
PRIMARY FIBER ROUTE WITH (1)
24-STR OM4 AND (1) 12-ST OS1
TO TR1AA-1
ROUTE FOR SECONDARY
FIBER SERVING BLDGS:
TR1AA
(1) 4"CONDUIT TO SERVER
ROOM ON 7TH FLOOR FOR
SERVICE PROVIDER USE
ROUTE FOR PRIMARY
FIBER SERVING BLDGS:
TR1AA
ROUTE FOR PRIMARY FIBER
SERVING BLDGS:
TR1B
TR40
ROUTE FOR SECONDARY
FIBER SERVING BLDGS:
TR40
PRIMARY FIBER ROUTE
WITH (1) 24-STR OM4 AND
(1) 12-ST OS1 TO EACH
CLOSET:
TR1B-6
TR1B-5
TR1B-4
TR1B-3
TR1B-2
TR1B-1
SECONDARY FIBER
ROUTE WITH (1) 24-STR
OM4 AND (1) 12-ST OS1
TO EACH CLOSET:
TR40-7
TR40-6
TR40-5
TR40-4
TR40-3
TR40-2
TR40-1
PRIMARY FIBER ROUTE
WITH (1) 24-STR OM4 AND
(1) 12-ST OS1 TO EACH
CLOSET:
TR40-7
TR40-6
TR40-5
TR40-4
TR40-3
TR40-2
TR40-1
ROUTE FOR PRIMARY FIBER
SERVING BLDGS:
TR32
TR30
TR11B
TR-11A
ROUTE FOR PRIMARY FIBER
SERVING BLDGS:
TR32
TR30
SECONDARY FIBER ROUTE
WITH (1) 24-ST OS2 TO
TR32-1, AND (1) 24-STR OM4
AND (1) 12-ST OS1 TO TR30-1
PRIMARY FIBER ROUTE
WITH (1) 24-ST OS2 TO
TR32-1, AND (1) 24-STR OM4
AND (1) 12-ST OS1 TO TR30-1
SECONDARY FIBER ROUTE
WITH (1) 24-ST OS2 TO
TR32-1
PRIMARY FIBER ROUTE
WITH (1) 24-ST OS2 TO
TR32-1
PRIMARY FIBER ROUTE WITH
(1) 24-STR OM4 AND (1) 12-ST
OS1 TO EACH CLOSET:
TR11A-7
TR11A-6
TR11A-5
TR11A-4
TR11A-3
TR11A-2
TR11A-1
PRIMARY FIBER ROUTE WITH
(1) 24-STR OM4 AND (1) 12-ST
OS1 TO EACH CLOSET:
TR11B-7
TR11B-6
TR11B-5
TR11B-4
TR11B-3
TR11B-2
TR11B-1
263 SHUMAN BOULEVARD
SUITE 550
NAPERVILLE, IL 60563
P: 630.527.2320
The FUTURE. Built Smarter www.imegcorp.com
PROJECT #21006425.00
13100 watertown plank road, suite 200 elm grove, wi 53122
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
NAGEL
project number:
B
IM
/2
.0
V
A -C h ic a g o
IL
-J
B E
H R
M /5
-7
.J
B E
H R
M .M
E P
T
C .r v t
/1
/2
:1 :5
A
M
00-TN101
FIRST FLOOR PLAN -
TECHNOLOGY
JESSE BROWN VAMC EHRM
INFRASTRUCTURE UPGRADES
820 S DAMEN AVE, CHICAGO, IL 60612
537-21-700
VA BLDG
18 AUG 2025 MARWIT ALFARA
ISSUED FOR BID &
CONSTRUCTION
FULLY SPRINKLERED
21011
1" = 30'-0"
FIRST FLOOR PLAN - TECHNOLOGY
SHEET NOTES:
1. REFER TO 1/T402 FOR ADDITIONAL
INFORMATION ON FIBER BACKBONE ROUTING.
1 0 1
SCALE: 1" = 1' - 0"
1" = 30'-0"
30 30 60
KEYNOTES:
1. IBER INSTALLED OUTDOOR SHALL BE
INSTALLED IN CONDUIT, PROVIDE (4) 4"
CONDUIT INSTALLED IN DUCTBANK WITH
HANDHOLE LOCATED AT BOTH ENDS PRIOR TO
ENTERING THE BUILDING.
Revisions: Date:
Ryan Bourland Text Box
12 MAR 2025,
18 AUG 2025 R1
Ryan Bourland Line
S S
S S
S
S SS
S S
S SS S S S S S S
SS SS SS S S S S S S S S S S S S S S S
S S
S S
S SS
S S
S S
S S
S S
TR1A
1A-2
LOBBY
RECEPTION
2444A
HUMAN
RESOURCES
OFFICE
CORRIDOR
C2405
WALL
PARTITION
CLOSET
2446G
ELECTRICAL
2446F
ELECTRICAL
2446E
COMPLIANCE
OFFICER
OFFICE
STORAGE
2446D
AUDITORIUM
ELEC
CLOSET
24E4
TEL CLOSET
24T1
FIRE CLOSET
2447A
FLEET
OPERATION
OFFICE
2449A
SUPV OFFICE
2449B
ELEVATOR
P7
ELEVATOR
P8
ELEVATOR
P1
ELEVATOR
P2
ELEVATOR
P3
ELEVATOR
P4
ELEVATOR
S6
ELEVATOR
S5
STAIR
DIRECTORS
STAFF
OFFICE AREA
ELEC
CLOSET
TEL
CORRIDOR
C2408
VOLUNTARY
STORAGE
MENS TOILET
STORAGE
2446A
WALL
PARTITION
CLOSET
2446H
CORRIDOR
C2409
CORRIDOR
C2404
VESTIBULE
STORAGE
STORAGE
STORAGE
SOILED
UTILITY
TOILET/SHOWER
AREA
2497A
WAITING RM
CORRIDOR
C2301
IRM
STORAGE
IRM
STORAGE
IRM
STORAGE
IRM
STORAGE
STORAGE
PATIENT RM
2522 TOILET
2521A
WOMENS
TOILET
WOMENS
LOCKER
HAC
CORRIDOR
C2502
STORAGE
STORAGE
2530KINESIOTHERAPY
CLINIC
CLOSET
2520A
MENS TOILET
MENS TOILET
LOCKER
2580A
STORAGE
OFFICE
STAFF
STAIR
ELEC
CLOSET
25E2
ELEC
CLOSET
WORK RM
OFFICE
PM AND R
SECY STAFF
CORRIDOR
PM AND R
CHIEF
RESIDENT
OFFICE
DOCTOR
OFFICE
CONFERENCE
RM
DOCTOR
OFFICE
DOCTOR
OFFICE
FAC
25E1
OT OFFICE
ELECTRICAL
CLOSET
STORAGE
MULTIPURPOSE
THERAPY
GENERAL
STORAGE
2554B
GENERAL
STORAGE
2554A
ADL RM
OCCUPATIONAL
THERAPY
KITCHEN
ASSESSMENT
OCCUPATIONAL
THERAPY
VESTIBULE
NORMAL
SUBSTATION
RM
2556A
EMERGENCY
SUBSTATION
RM
2556B
CLOSET
2585A
CLOSET
2585B
PHYSICAL
THERAPY
CLINIC
FUTURE
CORRIDOR
2585C
CANTEEN
STORAGE
AUTOPSY
AREA
REFR
2477A
MECH SPACE
MORGUE
CLEAN
UTILITY
CLEAN
UTILITY
MECH
ELEVATOR
SPACE
FAMILY
VIEWING
STORAGE
HAC
UNISEX
TOILET
2462 RECEPTION
PIV
FILE RM
PIV
NUCLEAR
MED CHIEF
PIV
NUCLEAR
MED
READING RM
VISUAL
CO-ORDR
BONE
DENSITY
PROCEDURE
RM
TOILET
2474A
NUCLEAR
MED OFFICE
LOW AND
BLIND VISION
STAFF
OFFICE
STORAGE
AND EQUIP
2446C
DRESSING
RM
2462A
NUCLEAR
MED
TOILET
CORRIDOR
C2403
INJECTION
RM
CARDIOLOGY
TREATMENT
PROCESSING
RM
WAITING
CORRIDOR
C2401
STRESS LAB
STORAGE
2492A
TREATMENT
RM
TREATMENT
RM
LAB
NUCLEAR
MEDICINE
SCANNING
AREA
ELEC
24E5
FAC
2479A
WOMENS
TOILET
KITCHEN
2446B
ASST
DIRECTOR
CHIEF OF
STAFF
ACOS CLINIC
AFFAIRS
OFFICE
AD OFFICE
MGR
ANALYST
PA OFFICE
FELLOW
OFFICE
WOMENS
TOILET
BREAK RM
ASST TO
DIRECTOR
SECY STAFF
OFFICE
CORRIDOR
C2406
NORTH
PENTHOUSE
BUILDING 30
STORAGE
STORAGE
2413A
LOUNGE /
KITCHEN
TOILET
2413B
SECRET
AREA
ASSOCIATE
DIRECTOR
CORRIDOR
C2407
SECRET
STORAGE
2440A
STORAGE
ELEC
ASSOCIATE
DIRECTOR
PATIENT
CARE
DIRECTOR
OFFICE
OFFICE
ASSOCIATE
DIRECTOR
MENS TOILET
SECRET
TEL
PI OFFICE
CONFERENCE
RM
STAFF
OFFICE
STAIRS
STAIRS
STAIRS
STAIRS
5A
TR 1B
1B-2
1.1
1.2
1.3
1.5
1.6
1.7
1.10
1.11
1.12
1.13
1.14 1.15
1.20
1.21
1.V1.O1.N1.M
1.4
1.J
1.J
X11 2.11
X12
2.12
2.13
2.14
2.A
X13
2.D
2.C5
2.A5
2.B 2.C
2.D9 2.G2.F2.E
3.P
3.N
3.M
3.L
3.K
3.J
3.H
3.G
3.F
3.23 3.24
5.U
5.S
5.C
5.27 5.30 5.32
5.35 5.38 5.435.41
5.N
5.G
5.34
5.37 5.40 5.445.44.5 5.49
5.Y
5.BB
1.22
1.H1.G1.F 1.K 1.P 1.Q 1.R
1.19
1.18
1.17
1.16
1.8
1.A 1.B 1.C 1.D 1.E
1.L
3.J1
1.I
V2V1
VB
VA
1.S 1.T 1.U
1.U2
5.A
Y3
EXISTING TR 24T1
TR1A-2
ALL LOW VOLTAGE CABLING
IN THIS AREA SHALL BE
SERVED FROM TR1B-2
TR1B-2
ALL LOW VOLTAGE CABLING
IN THIS AREA SHALL BE
SERVED FROM TR1B-2
ALL LOW VOLTAGE CABLING
IN THIS AREA SHALL BE
SERVED FROM TR1A-2
ALL LOW VOLTAGE CABLING
IN THIS AREA SHALL BE
SERVED FROM TR40-2
SECONDARY FIBER ROUTE
WITH (1) 24-STR OM4 AND (1)
12-ST OS1 TO EACH CLOSET:
TR1B-6
TR1B-5
TR1B-4
TR1B-3
TR1B-2
TR1B-1
ROUTE FOR SECONDARY
FIBER SERVING BLDGS:
TR-1B
SECONDARY ROUTE FOR
FIBER SERVING BLDGS:
TR-1A
TR-1B
TR-11A
TR-11B
ROUTE FOR SECONDARY
FIBER SERVING BLDGS:
TR-1A
LOCATION OF (1) 4"
VERTICAL CONDUIT RISER
FOR SERVICE PROVIDER
FROM DEMARC TO SERVER
ROOM
KINESIOTHERAPY
CLINIC
PHYSICAL
THERAPY
CLINIC
FUTURE
CORRIDOR
2585C
STORAGE
OFFICE
STAFF
STAIR
PM AND R
SECY STAFF
WORK RM
OFFICE
CORRIDOR
CORRIDOR
C2502
MENS TOILET
MENS TOILET
LOCKER
2580A
CYSTOSCOPY
CYSTO
CLEAN UP
RM
2602A
OR-7
CYSTO
STORAGE
2602B
OR-6
2606 ELEVATOR
OR-5
STERILE
CORE ANNEX
STERILE
CORE
ELEC RM
26E2
STERILE
MACH
STAIR
ELEVATOR
VESTIBULE
OR-3
OR SUPPORT
OR-2
VESTIBULE
OR-1
EQUIP
STORAGE
OR SUPPORT
EQUIP
STORAGE
CLEAN LINEN
HAC
26H1
OR-4
CORRIDOR
C2601
CORRIDOR
C2602
O…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .