Attachment 5 - Hazardous Materials - Drawings.pdf

PDF 3 MB Posted

Attached to
EHRM Infrastructure Construction Grand Island Project #636-21-701
Solicitation number
36C77623B0002
Issued by

About this file

This document package includes hazardous materials drawings and a federal contract opportunity notice for construction services. The hazardous materials drawings depict asbestos-containing materials and lead-based paint located throughout five floors and the basement of an EHRM Infrastructure Upgrades project at the Grand Island VAMC. The project number is 636-21-701. The federal contract opportunity is for the construction of these EHRM Infrastructure Upgrades with a solicitation number of 36C77623B0002. The agency issuing this opportunity is the Department of Veterans Affairs Technology Acquisition Center located in Austin, Texas.

View the file

Other files

File Type Posted
36C77623B0002 0004 Amendment - Bid Opening and Wage Rates.pdf PDF
Attachment 15 - Construction Wage Rates - Hall 01-13-2022.pdf PDF
ADD 1 - 01 Reports - 1947 Original Construction A2.pdf PDF
Alesia Addendum 1.pdf PDF
ADD 1 - 02 Project Manual - 07 40 00 - ROOFING AND SIDING PANELS - Addendum 1.pdf PDF
ADD 1 - 03 Architectural - A-701.pdf PDF
ADD 1 - 01 Reports - Geotechnical Report 20220114 TD2.pdf PDF
ADD 1 - 02 Project Manual - 09 06 00 - SCHEDULE FOR FINISHES - Addendum 1.pdf PDF
ADD 1 - 03 Architectural - 19-A-102.pdf PDF
ADD 1 - 02 Project Manual - 26 32 13 - ENGINE GENERATORS - Addendum 1.pdf PDF
36C77623B0002 Amendment 0003 - Addendum 1.pdf PDF
ADD 1 - 02 Project Manual - 00 01 10 - TABLE OF CONTENTS - Addendum 1.pdf PDF
ADD 1 - 03 Architectural - A-601.pdf PDF
ADD 1 - 01 Reports - HAZMAT Report GI VA EHRM 01-10-22.pdf PDF
SES Addendum 1.pdf PDF
ADD 1 - 03 General - GI002.pdf PDF
ADD 1 - 05 ME - ME Drawings Add 01.pdf PDF
ADD 1 - 03 Architectural - 19-A-201.pdf PDF
ADD 1 - 04 Civil - C3.0.pdf PDF
ADD 1 - 04 Civil - C2.0.pdf PDF
ADD 1 - 01 Reports - 1947 Original Construction S3.pdf PDF
36C77623B0002 Grand Island EHRM - Technical Questions and Answers.pdf PDF
36C77623B0002 0001 IFB Amendment - Grand Island.pdf PDF
Site Visit Sign-in Sheet - Grand Island.pdf PDF
Questions - 36C77623B0002 Grand Island.pdf PDF
Attachment 9 - Mechanical - Drawings.pdf PDF
Attachment 16 - Site Visit Instructions.pdf PDF
Attachment 4 - Life Safety - Drawings.pdf PDF
Attachment 1 - Specifications 1.pdf PDF
Attachment 6 - Civil - Drawings.pdf PDF
Attachment 12 - COVID-19 Safety Protocols 12-14-21.pdf PDF
Attachment 13 - Limitations on Subcontracting - Construction.pdf PDF
Attachment 15 - Construction Wage Rates - Hall 09-02-2022.pdf PDF
Attachment 11 - Technology - Drawings.pdf PDF
Attachment 2 - Specifications 2.pdf PDF
Attachment 14 - Contractor Safety - Environmental Form.pdf PDF
36C77623B0002_1.pdf PDF
Attachment 10 - Electrical - Drawings.pdf PDF
Attachment 7 - Structural - Drawings.pdf PDF
Attachment 8 - Architectural - Drawings.pdf PDF
Attachment 3 - Drawings Sheet Index.pdf PDF
Show all 41

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

41 2 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28

A

B

C

D

E

F

G

H

J

K

L

M

N

P

R

S

T

U

V

W

X

Y

Z

AA

BB

CC

DD

CANTEEN

OFFICE

C6

COMM

C5

MENS

TOILET

C7

WAREHOUSE

SUPPLY

RM

C8

BIO

MED

SHOP/OFFICE

C9

EEMS

STORAGE

C10

WAREHOUSE

STORAGE

C11

WAREHOUSE

STORAGE

C12

CANTEEN

STORAGE

C13

STORAGE

C14

STORAGE

C15

ER

SUPPLY

C16

C17

SUPPLY

WAREHOUSE

C18

PROSTHETICS

C19

STORAGE

C20

STAIR

NO-6

STORAGE

C17E

MECH

C17B

MECH

C21

CHILLER

RM

G03

WAREHOUSE

STORAGE

C26

WAREHOUSE

STORAGE

C27

OFFICE

N02

MIKE

SAFETY

N03

SOILED

LINEN

CHUTE

N04LOCKER

RM

N05

PAHTOLOGY

N06

OFFICE

N07

IT

OPERATORS

N08

TEL

SWITCH

N09A

N10

IT

SERVICES

N11

IT

OFFICE

N12

UNISEX

TOILET

N13 N14

WOMENS

LOCKER

N14A

IT

STORAGE

N15ALOCKER

N17

STORAGE

N18

STORAGE

C22

CRAWL

SPACE

NO.7

CRAWL

SPACE

NO.6

SERVER

RM

C01

CRAWL

SPACE

NO.8

CRAWL

SPACE

NO.9

S10

MAIL

RM

S9

MAIL

RM

OFFICE

S8

ARMORY

C23

POLICE

OFFICE

S4

FITNESS

CENTER

S6

STAIR

NO 4

SE2SE1

SPS

DISPATCH

S1 OFFICE

C24 OFFICE

S2 S3

SOILED

LINEN

S7

IT

C25

SPS

LOCKER

RM

C28

EQUIP

RM

NE3A

EQUIR

RM

NE3B

NE3

NE2

OFFFICE

NE1

MENS

TOILET

C29

WOMENS

TOILET

C30

RESTROOM

C31

1/16" = 1'-0"1 GROUND FLOOR - HAZARDOUS MATERIALS PLAN

SUMMARY OF ASBESTOS CONTAINING MATERIALS

KEY NOTE DESCRIPTION FRIABLE QTY HATCHING

1 LAMINATE FLOORING (TAN) NF 150 SF

2 DUCT MASTIC (LIGHT RED) NF 250 LF

3 12" X 12" FLOOR TILE (BEIGE) NF 150 SF

4 9" X 9" FLOOR TILE (BLACK) NF 16 SF

5 12" X 12" FLOOR TILE (BLACK) NF 150 SF

6 12" X 12" FLOOR TILE (BEIGE) NF 10 SF

2 2

ASBESTOS NOTES

GENERAL NOTES:

1. THESE DRAWINGS ARE DIAGRAMMATIC AND FOR GENERAL IDENTIFICATION OF ASBESTOS-CONTAINING MATERIALS (ACM) AND LEAD-BASED PAINT (LBP) SUBJECT TO REMOVAL OR DISTURBANCE. THEIR ACCURACY IS NOT GUARANTEED. LOCATIONS AND QUANTITIES SHOWN OF ACM AND LBP TO BE REMOVED ARE REPRESENTATIVE BASED ON RECENT AND PREEXISTING SITE SURVEY INFORMATION. THE ABATEMENT CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL MATERIAL

LOCATIONS AND REMOVAL QUANTITIES, AND EXISTING SITE CONDITIONS.

2. ASBESTOS REMOVAL IS BEING PERFORMED PURSUANT TO RENOVATION OF THE PROJECT AREAS. REMOVE AND DISPOSE OF ALL ACM IN ACCORDANCE WITH APPLICABLE REGULATIONS, PROJECT SPECIFICATIONS, AND THE APPROVED ASBESTOS HAZARD ABATEMENT PLAN (AHAP). IF SUSPECT ACMS ARE ENCOUNTERED DURING CONSTRUCTION AND DEMOLITION THAT ARE NOT IDENTIFIED ON THE ASBESTOS ABATEMENT DRAWINGS, STOP WORK AND CONTACT THE PROJECT MANAGER AND VPIH.

3. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL REGULATIONS; PROJECT SPECIFICATIONS, THE APPROVED WORK PLAN, AND ACCEPTED INDUSTRY PRACTICE. WHEN REQUIREMENTS OVERLAP OR CONFLICT, THE MOST STRINGENT REQUIREMENT SHALL APPLY. ALL WORK SHALL BE SUBJECT TO INSPECTION BY THE OWNER, THE OWNER'S CONSULTANTS, AND REGULATORY PERSONNEL.

4. DEMOLITION OF NON-ACM BUILDING MATERIALS MAY BE REQUIRED TO ACCESS REGULATED MATERIALS, INCLUDING, BUT NOT LIMITED TO, CABINETS, RAISED FLOORING, GYPSUM WALLBOARD, EXPANDED METAL OR WOOD LATH AND PLASTER WALLS AND CEILINGS, WALL FRAMING, CARPET, CERAMIC AND VINYL FLOOR COVERINGS, WOOD, ETC. THE ABATEMENT CONTRACTOR SHALL BE RESPONSIBLE FOR DEMOLITION OF NON-ACM MATERIALS AS NEEDED TO ACCESS REGULATED MATERIALS FOR ABATEMENT, AND FOR COORDINATING THE LIMITS OF DEMOLITION AND ABATEMENT WITH THE GENERAL CONTRACTOR.

5. ALL COSTS ASSOCIATED WITH EXPLORATORY DEMOLITION AND DEMOLITION OF NON-ACM MATERIALS NEEDED TO ACCOMPLISH ABATEMENT SHALL BE INCLUDED IN THE ABATEMENT CONTRACTOR'S LUMP SUM PRICE FOR THE PROJECT. NO ADDITIONAL

COMPENSATION SHALL BE CONSIDERED FOR THIS WORK.

ASBESTOS NOTES:

1. THE PROJECT AREA WAS RECENTLY SURVEYED FOR ACM. REFER TO THE HAZARDOUS BUILDING MATERIALS INSPECTION REPORT BY AMI ENVIRONMENTAL, DATED NOVEMBER 16, 2021 FOR MORE INFORMATION ABOUT ACMS IDENTIFIED IN THE

PROJECT AREA.

2. CONCEALED ACM PIPE INSULATION (TSI) MAY EXIST WITHIN WALLS, PIPE CHASES AND ABOVE RIGID CEILINGS. COORDINATE ACCESS WITH DEMOLITION DRAWINGS AND THE GENERAL CONTRACTOR. SOME EXPLORATORY DEMOLITION MAY BE REQUIRED

TO DETERMINE IF CONCEALED ACM IS PRESENT.

3. IF SUSPECT ACM IS DISCOVERED IN CONSTRUCTION, STOP WORK AND CONTACT GENERAL CONTRACTOR, VA

REPRESENTATIVES AND VPIH.

4. GASKETS AND PACKINGS ARE CONCEALED IN VALVES, EQUIPMENT, STEAM TRAPS, BOILERS AND FLUES AND ARE INACCESSIBLE FOR SAMPLING. GASKETS AND PACKINGS ARE ASSUMED AS ACM UNLESS SAMPLED, ANALYZED, AND DETERMINED TO BE

NON-ASBESTOS.

5. ESTABLISH REGULATED AREAS (RA) AND NEGATIVE PRESSURE ENCLOSURES (NPE) AND PERFORM REMOVAL IN ACCORDANCE WITH APPLICABLE SPECIFICATION SECTIONS: SEC 02 82 13-13, GLOVEBAG ASBESTOS ABATEMENT; SEC 02 82 11, TRADITIONAL

ASBESTOS ABATEMENT; SEC 02 82 13-19, ASBESTOS FLOOR TILE AND MASTIC ABATEMENT.

6. FINALIZE LIMITS OF REGULATED AREAS, LOCATIONS OF NEGATIVE AIR MACHINES (NAM), PERSONAL DECONTAMINATION FACILITIES (PDF), AND WASTE DECONTAMINATION FACILITIES (WDF) BASED ON SITE CONDITIONS, BEST PRACTICES AND

PHASING REQUIREMENTS.

7. ASSUME 50% EFFICIENCY WHEN CALCULATING NAM REQUIREMENTS FOR ACHIEVING FOUR (4) AIR CHANGES PER HOUR AND PROVIDED GREATER THAN -0.02” WCG PRESSURE. CONFIGURE AND PLACE NAMS AS NEEDED TO MAXIMIZE AIR MOVEMENT AND PREVENT DEAD AIR SPACE. COORDINATE NEGATIVE AIR DISCHARGE LOCATIONS WITH GENERAL CONTRACTOR, OWNER'S

REPRESENTATIVE, AND VPIH, IF NEEDED.

ASBESTOS ABATEMENT PHASING:

1. THE ABATEMENT CONTRACTOR SHALL WORK CLOSELY WITH THE GENERAL CONTRACTOR, CONTRACTING OFFICER, OWNER OR OWNER'S REPRESENTATIVE, AND/OR THE VPIH TO COORDINATE REMOVAL OF ACM IN ACCORDANCE WITH PROJECT SCHEDULING, SEQUENCING, AND PHASING REQUIREMENTS. SOME AFTER HOURS AND WEEK-END WORK MAY BE REQUIRED.

PHASING IS SUBJECT TO CHANGE TO ACCOMMODATE SITE CONDITIONS AND FACILITY OPERATIONS.

TRUE

NORTH

PLAN

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

636A-21-701EHRM INFRASTRUCTURE

UPGRADES

CONSTRUCTION

DOCUMENTS

GRAND ISLAND, NE

Alesia Architecture P.C.

3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941

Shaffer Stevens & Schaap P.C.

9910 North 48th Street Omaha, Nebraska 68152 Phone: (402) 455-7698

Specialized Engineering Solutions 10360 Ellison Circle Omaha, NE 68134 Phone: (402) 991-5520

IMEG Corp.

2882 106th Street Des Moines, IA 50322 Phone (515) 334-4324

Thompson, Dreessen & Dorner, Inc.

10836 Old Mill Rd Omaha, NE 68154 Phone: (402) 330-8860

AMI Environmental Inc 8802 S 135th Street Omaha, NE 68138 Phone: (402) 397-5001

3 4

10 11

6 191

KEYPLAN

BI

M

-1

6a -2

1-

- V

A G ra nd

Is la nd E

H R

M /6

_2

1_ Bl dg

1.

rv t 3/

/2

:3

1:

A M

1-HA10G

GROUND FLOOR – HAZARDOUS

MATERIALS - ASBESTOS – BLDG 1 1

Revisions: Date: 9/1/2022 CL MET

B

C

D

E

F

G

H

J

K

L

M

N

P

R

S

T

U

V

W

X

Y

Z

AA

BB

CC

DD

TREATMENT

NE101

SUPPLY

NE104

SOILED

NE105

OFFICE

NE106

OFFICE

NE107

HAC

NE108

LAB

NE109

CANTEEN

N102

OFFICE

N103

FEMALE

TOILET

N104

MALE

TOILET

N105

OFFICE

N106

PATIENT

EDUCATION

N107

WAITING

N112

OFFICE

N115

OFFICE

N116

CASHIER

N117

STAIR

NO-3

CLINICAL

PHARMACIST

NW101

EXAM

RM

NW102

EXAM

RM

NW103

EXAM

RM

NW104

STORAGE

NW105

EXAM

RM

NW106

EXAM

RM

NW107

EXAM

RM

NW108

CLEAN

UTILITY

NW109

SOILED

UTILITY

NW110

EXAM

RM

NW111

CLEAN

LINEN

NW112

EXAM

RM

NW113

NURSE

STATION

NW114

EXAM

RM

NW115

EXAM

RM

NW116

CLINICAL

PHARMACIST

NW117

STAIR

NO-1

TOILET

NW107A

TOILET

NW108A

TOILET

NW111A

LOBBY

COMM

C100

C101

OFFFICE

C101E

CONFERENCE

RM

C101D

FOOD

STORAGE

C32

VEG RM

C33

FREEZER

C102A

FREEZER

C102

C102B

FREEZER

C103

FREEZER

C113A

WOMENS

TOILET

C104

LINEN

CLOSET

C105

STORAGE

C106

FREEZER

C112

MALE

TOILET

C107

STORAGE

C111

WASH

RM HAC

C110

HAC

C109C108

STAIR

C34

INPATIENT

PHARMACY

SE102

IV

DISPENSING

SE103

SE104

CONFERENCE

RM

SE106

CHIEF

PHARMACY

SE107

VACANT

SE108

OFFICE

SE109

REST

RM

SE110

REST

RM

SE111

CONTROL

SUBSTANCE

SE112

PRESCRIPTIONS

SE115

PATIENT

RECIEVING

SE116

VACANT

SE117

MD

EXAM

SE118

EXAM

RM

SE119

MD

EXAM

SE120

EXAM

RM

SE121

SE122

EXAM

RM

SE124

MD

EXAM

SE125

MD

EXAM

SE126

EXAM

RM

SE127

NURSE

SE128

CLEAN

UTILITY

SE130

SOILED

UTILITY

SE131

ELIGIBILTY

SE133

NUTRITION

CLINIC

SE134

EXAM

RM

SE135

OFFICE

SE136

OFFICE

SE137

ELECTRICAL

SE138

TOILET

SE139

EXAM

RM

SE140

OFFICE

SE141

EXAM

RM

SE142

MD

EXAM

SE143

TELEHEALTH

SE144

TELEMEDICINE

SE145

SOCIAL

WORK

SE147

OFFICE

SE148

STAIR

NO-4

STAIR

NO-5

HAC

SE151

TRIAGE

SE152

SOCIAL

WORKER

SE153

MINOR

TREATMENT

SE154

CONFERENCE

RM

SE155

MALE

TOILET

S111

WOMENS

TOILET

S110

ADVOCATE

OFFICE

S109 S108

RECEPTION

SW102A

NURSE

STATION

SW103

PROVIDER

STATION

SW104

EXAM

RM

SW105

EXAM

RM

SW106

EXAM

RM

SW107

SW108

EXAM

RM

SW109SW110

EXAM

RM

SW113

EXAM

RM

SW114

TOILET

SW115A

CLINICAL

PHARMACIST

SW116

TOILET

SW117

TOILET

SW118

SW119

TREATMENT

SW102B

POLICE

AMBULANCE

ENTRANCE

SE156

Room

OUTPATIENT

PHARMACY

SE114

ACTIVE

STORAGE

SE113

PASSAGE

SE105

1/16" = 1'-0"1 FIRST FLOOR - HAZARDOUS MATERIALS PLAN

SUMMARY OF ASBESTOS CONTAINING MATERIALS

KEY NOTE DESCRIPTION FRIABLE QTY HATCHING

1 LAMINATE FLOORING (TAN) NF 150 SF

2 DUCT MASTIC (LIGHT RED) NF 250 LF

3 12" X 12" FLOOR TILE (BEIGE) NF 150 SF

4 9" X 9" FLOOR TILE (BLACK) NF 16 SF

ASBESTOS NOTES

GENERAL NOTES:

1. THESE DRAWINGS ARE DIAGRAMMATIC AND FOR GENERAL IDENTIFICATION OF ASBESTOS-CONTAINING MATERIALS (ACM) AND LEAD-BASED PAINT (LBP) SUBJECT TO REMOVAL OR DISTURBANCE. THEIR ACCURACY IS NOT GUARANTEED. LOCATIONS AND QUANTITIES SHOWN OF ACM AND LBP TO BE REMOVED ARE REPRESENTATIVE BASED ON RECENT AND PREEXISTING SITE SURVEY INFORMATION. THE ABATEMENT CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL MATERIAL

LOCATIONS AND REMOVAL QUANTITIES, AND EXISTING SITE CONDITIONS.

2. ASBESTOS REMOVAL IS BEING PERFORMED PURSUANT TO RENOVATION OF THE PROJECT AREAS. REMOVE AND DISPOSE OF ALL ACM IN ACCORDANCE WITH APPLICABLE REGULATIONS, PROJECT SPECIFICATIONS, AND THE APPROVED ASBESTOS HAZARD ABATEMENT PLAN (AHAP). IF SUSPECT ACMS ARE ENCOUNTERED DURING CONSTRUCTION AND DEMOLITION THAT ARE NOT IDENTIFIED ON THE ASBESTOS ABATEMENT DRAWINGS, STOP WORK AND CONTACT THE PROJECT MANAGER AND VPIH.

3. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL REGULATIONS; PROJECT SPECIFICATIONS, THE APPROVED WORK PLAN, AND ACCEPTED INDUSTRY PRACTICE. WHEN REQUIREMENTS OVERLAP OR CONFLICT, THE MOST STRINGENT REQUIREMENT SHALL APPLY. ALL WORK SHALL BE SUBJECT TO INSPECTION BY THE OWNER, THE OWNER'S CONSULTANTS, AND REGULATORY PERSONNEL.

4. DEMOLITION OF NON-ACM BUILDING MATERIALS MAY BE REQUIRED TO ACCESS REGULATED MATERIALS, INCLUDING, BUT NOT LIMITED TO, CABINETS, RAISED FLOORING, GYPSUM WALLBOARD, EXPANDED METAL OR WOOD LATH AND PLASTER WALLS AND CEILINGS, WALL FRAMING, CARPET, CERAMIC AND VINYL FLOOR COVERINGS, WOOD, ETC. THE ABATEMENT CONTRACTOR SHALL BE RESPONSIBLE FOR DEMOLITION OF NON-ACM MATERIALS AS NEEDED TO ACCESS REGULATED MATERIALS FOR ABATEMENT, AND FOR COORDINATING THE LIMITS OF DEMOLITION AND ABATEMENT WITH THE GENERAL CONTRACTOR.

5. ALL COSTS ASSOCIATED WITH EXPLORATORY DEMOLITION AND DEMOLITION OF NON-ACM MATERIALS NEEDED TO ACCOMPLISH ABATEMENT SHALL BE INCLUDED IN THE ABATEMENT CONTRACTOR'S LUMP SUM PRICE FOR THE PROJECT. NO ADDITIONAL

COMPENSATION SHALL BE CONSIDERED FOR THIS WORK.

ASBESTOS NOTES:

1. THE PROJECT AREA WAS RECENTLY SURVEYED FOR ACM. REFER TO THE HAZARDOUS BUILDING MATERIALS INSPECTION REPORT BY AMI ENVIRONMENTAL, DATED NOVEMBER 16, 2021 FOR MORE INFORMATION ABOUT ACMS IDENTIFIED IN THE

PROJECT AREA.

2. CONCEALED ACM PIPE INSULATION (TSI) MAY EXIST WITHIN WALLS, PIPE CHASES AND ABOVE RIGID CEILINGS. COORDINATE ACCESS WITH DEMOLITION DRAWINGS AND THE GENERAL CONTRACTOR. SOME EXPLORATORY DEMOLITION MAY BE REQUIRED

TO DETERMINE IF CONCEALED ACM IS PRESENT.

3. IF SUSPECT ACM IS DISCOVERED IN CONSTRUCTION, STOP WORK AND CONTACT GENERAL CONTRACTOR, VA

REPRESENTATIVES AND VPIH.

4. GASKETS AND PACKINGS ARE CONCEALED IN VALVES, EQUIPMENT, STEAM TRAPS, BOILERS AND FLUES AND ARE INACCESSIBLE FOR SAMPLING. GASKETS AND PACKINGS ARE ASSUMED AS ACM UNLESS SAMPLED, ANALYZED, AND DETERMINED TO BE

NON-ASBESTOS.

5. ESTABLISH REGULATED AREAS (RA) AND NEGATIVE PRESSURE ENCLOSURES (NPE) AND PERFORM REMOVAL IN ACCORDANCE WITH APPLICABLE SPECIFICATION SECTIONS: SEC 02 82 13-13, GLOVEBAG ASBESTOS ABATEMENT; SEC 02 82 11, TRADITIONAL

ASBESTOS ABATEMENT; SEC 02 82 13-19, ASBESTOS FLOOR TILE AND MASTIC ABATEMENT.

6. FINALIZE LIMITS OF REGULATED AREAS, LOCATIONS OF NEGATIVE AIR MACHINES (NAM), PERSONAL DECONTAMINATION FACILITIES (PDF), AND WASTE DECONTAMINATION FACILITIES (WDF) BASED ON SITE CONDITIONS, BEST PRACTICES AND

PHASING REQUIREMENTS.

7. ASSUME 50% EFFICIENCY WHEN CALCULATING NAM REQUIREMENTS FOR ACHIEVING FOUR (4) AIR CHANGES PER HOUR AND PROVIDED GREATER THAN -0.02” WCG PRESSURE. CONFIGURE AND PLACE NAMS AS NEEDED TO MAXIMIZE AIR MOVEMENT AND PREVENT DEAD AIR SPACE. COORDINATE NEGATIVE AIR DISCHARGE LOCATIONS WITH GENERAL CONTRACTOR, OWNER'S

REPRESENTATIVE, AND VPIH, IF NEEDED.

ASBESTOS ABATEMENT PHASING:

1. THE ABATEMENT CONTRACTOR SHALL WORK CLOSELY WITH THE GENERAL CONTRACTOR, CONTRACTING OFFICER, OWNER OR OWNER'S REPRESENTATIVE, AND/OR THE VPIH TO COORDINATE REMOVAL OF ACM IN ACCORDANCE WITH PROJECT SCHEDULING, SEQUENCING, AND PHASING REQUIREMENTS. SOME AFTER HOURS AND WEEK-END WORK MAY BE REQUIRED.

PHASING IS SUBJECT TO CHANGE TO ACCOMMODATE SITE CONDITIONS AND FACILITY OPERATIONS.

CL MET

TRUE

NORTH

PLAN

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

636A-21-701EHRM INFRASTRUCTURE

UPGRADES

GRAND ISLAND, NE

Alesia Architecture P.C.

3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941

Shaffer Stevens & Schaap P.C.

9910 North 48th Street Omaha, Nebraska 68152 Phone: (402) 455-7698

Specialized Engineering Solutions 10360 Ellison Circle Omaha, NE 68134 Phone: (402) 991-5520

IMEG Corp.

2882 106th Street Des Moines, IA 50322 Phone (515) 334-4324

Thompson, Dreessen & Dorner, Inc.

10836 Old Mill Rd Omaha, NE 68154 Phone: (402) 330-8860

AMI Environmental Inc 8802 S 135th Street Omaha, NE 68138 Phone: (402) 397-5001

3 4

10 11

6 191

KEYPLAN

BI

M

-1

6a -2

1-

- V

A G ra nd

Is la nd E

H R

M /6

_2

1_ Bl dg

1.

rv t 3/

/2

:3

2:

A M

1-HA101

FIRST FLOOR – HAZARDOUS MATERIALS -

ASBESTOS – BLDG 1 1

Revisions: Date:

CONSTRUCTION

DOCUMENTS

9/1/2022

42 5 6 7 8 9 10 11

12 13 14 15 16 17 18 19

20 21 22 23 24 25 26 27 28

A

B

C

D

E

F

G

H

J

K

L

M

N

P

R

S

T

U

V

W

X

Y

Z

AA

BB

CC

DD

LAB

SE201

ELECTRICAL

SE202

MECH

SE202A

MENS

TOILET

SE203

SE204

SE205

WOMENS

TOILET

SE206

OFFICE

SE207

OFFICE

SE208

STAIR

SE123

OFFICE

SE210

LAB

STORAGE

SE201A

S201

OFFICE

S202

TREATMENT

S203

THERAPY

S204

HVAC

S205

LOCKER

S206

LAB

STORAGE

S207

WAITING

S208STORAGE

S209

OFFICE

S211

GAIT

RM

S212

EQUIPMENT

SOTRAGE

S213

KITCHEN

S203A

CONFERENCE

RM

S206A

SOILED

UTILITY

S216

O AND

P LAB

C200

COMM

C201

CHAPEL

C202

RECREATIONAL

HALL

C203

CHAPLIN

C202B

VOL

SERVICES

C203A

VOL

SVS

KITCHEN

C203B

C207

OFFICE

C208

OFFICE

C209OFFICE

C210

OFFICE

C211

OFFICE

C212

STORAGE

C213

PT RM

C214

STAIR

NO-7

STORAGE

C202A

CLEAN

LINEN

C217

CHAPLAIN

SE149 STAIR

SE150

MECH

C220

RESTROOM

C221 STORAGE

C222

RECEPTION

N201

WAITING

RM

N202

AUDIOLOGY

N203

EXAM

N204

EXAM

N205

EXAM

N206

EXAM

N207

STAIR

SE157

HAC

N209

EXAM

N210

EXAM

N211

TOILET

NE212A

WOMENS

RESTROOM

N214

MENS

RESTROOM

N215

STORAGE

N213

AUDIIOLOGY

OFFICE

NW201

AUDIOLOGY

EXAM

NW202

AUDIOLOGY

NW203

STAIR

SE158

OFFICE

NW205

TREATMENT

RM

NW206

TREATMENT

RM

NW207

EXAM

NW208

EXAM

NW209

EXAM

NW210

STORAGE

NW211

BOOTH

SE159

NW213

TREATMENT

RM

NW205B

TOILET

NW207A

NW

205C

NW205C

SOILED

HOLD

NE201

PROCED

NE202

EXAM

NE203

EXAM

NE204

EXAM

NE205

LINEN

NE206 EXAM

NE207

EXAM

NE208

STORAGE

NE209

STAFF

NE210

SUPPLY

NE211

PROCED

NE212

WAITING

SW213A

ULTRASOUND

SW201

MECH

SW202

TOILET

SW203

X-RAY

SW204

WORK

RM

SW205

TOILET

SW206

X-RAY

SW207SW208

CONTROL

RM

SW209

BREAK

RM

SW210

X-RAY

SW211

VASCULAR

PROCEDURE

RM

SW212

CHECKING

SW213

TOILET

SW201A

1/16" = 1'-0"1 SECOND FLOOR - HAZARDOUS MATERIALS PLAN

SUMMARY OF ASBESTOS CONTAINING MATERIALS

KEY NOTE DESCRIPTION FRIABLE QTY HATCHING

1 LAMINATE FLOORING (TAN) NF 150 SF

2 DUCT MASTIC (LIGHT RED) NF 250 LF

3 12" X 12" FLOOR TILE (BEIGE) NF 150 SF

4 9" X 9" FLOOR TILE (BLACK) NF 16 SF

ASBESTOS NOTES

GENERAL NOTES:

1. THESE DRAWINGS ARE DIAGRAMMATIC AND FOR GENERAL IDENTIFICATION OF ASBESTOS-CONTAINING MATERIALS (ACM) AND LEAD-BASED PAINT (LBP) SUBJECT TO REMOVAL OR DISTURBANCE. THEIR ACCURACY IS NOT GUARANTEED. LOCATIONS AND QUANTITIES SHOWN OF ACM AND LBP TO BE REMOVED ARE REPRESENTATIVE BASED ON RECENT AND PREEXISTING SITE SURVEY INFORMATION. THE ABATEMENT CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL MATERIAL

LOCATIONS AND REMOVAL QUANTITIES, AND EXISTING SITE CONDITIONS.

2. ASBESTOS REMOVAL IS BEING PERFORMED PURSUANT TO RENOVATION OF THE PROJECT AREAS. REMOVE AND DISPOSE OF ALL ACM IN ACCORDANCE WITH APPLICABLE REGULATIONS, PROJECT SPECIFICATIONS, AND THE APPROVED ASBESTOS HAZARD ABATEMENT PLAN (AHAP). IF SUSPECT ACMS ARE ENCOUNTERED DURING CONSTRUCTION AND DEMOLITION THAT ARE NOT IDENTIFIED ON THE ASBESTOS ABATEMENT DRAWINGS, STOP WORK AND CONTACT THE PROJECT MANAGER AND VPIH.

3. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL REGULATIONS; PROJECT SPECIFICATIONS, THE APPROVED WORK PLAN, AND ACCEPTED INDUSTRY PRACTICE. WHEN REQUIREMENTS OVERLAP OR CONFLICT, THE MOST STRINGENT REQUIREMENT SHALL APPLY. ALL WORK SHALL BE SUBJECT TO INSPECTION BY THE OWNER, THE OWNER'S CONSULTANTS, AND REGULATORY PERSONNEL.

4. DEMOLITION OF NON-ACM BUILDING MATERIALS MAY BE REQUIRED TO ACCESS REGULATED MATERIALS, INCLUDING, BUT NOT LIMITED TO, CABINETS, RAISED FLOORING, GYPSUM WALLBOARD, EXPANDED METAL OR WOOD LATH AND PLASTER WALLS AND CEILINGS, WALL FRAMING, CARPET, CERAMIC AND VINYL FLOOR COVERINGS, WOOD, ETC. THE ABATEMENT CONTRACTOR SHALL BE RESPONSIBLE FOR DEMOLITION OF NON-ACM MATERIALS AS NEEDED TO ACCESS REGULATED MATERIALS FOR ABATEMENT, AND FOR COORDINATING THE LIMITS OF DEMOLITION AND ABATEMENT WITH THE GENERAL CONTRACTOR.

5. ALL COSTS ASSOCIATED WITH EXPLORATORY DEMOLITION AND DEMOLITION OF NON-ACM MATERIALS NEEDED TO ACCOMPLISH ABATEMENT SHALL BE INCLUDED IN THE ABATEMENT CONTRACTOR'S LUMP SUM PRICE FOR THE PROJECT. NO ADDITIONAL

COMPENSATION SHALL BE CONSIDERED FOR THIS WORK.

ASBESTOS NOTES:

1. THE PROJECT AREA WAS RECENTLY SURVEYED FOR ACM. REFER TO THE HAZARDOUS BUILDING MATERIALS INSPECTION REPORT BY AMI ENVIRONMENTAL, DATED NOVEMBER 16, 2021 FOR MORE INFORMATION ABOUT ACMS IDENTIFIED IN THE

PROJECT AREA.

2. CONCEALED ACM PIPE INSULATION (TSI) MAY EXIST WITHIN WALLS, PIPE CHASES AND ABOVE RIGID CEILINGS. COORDINATE ACCESS WITH DEMOLITION DRAWINGS AND THE GENERAL CONTRACTOR. SOME EXPLORATORY DEMOLITION MAY BE REQUIRED

TO DETERMINE IF CONCEALED ACM IS PRESENT.

3. IF SUSPECT ACM IS DISCOVERED IN CONSTRUCTION, STOP WORK AND CONTACT GENERAL CONTRACTOR, VA

REPRESENTATIVES AND VPIH.

4. GASKETS AND PACKINGS ARE CONCEALED IN VALVES, EQUIPMENT, STEAM TRAPS, BOILERS AND FLUES AND ARE INACCESSIBLE FOR SAMPLING. GASKETS AND PACKINGS ARE ASSUMED AS ACM UNLESS SAMPLED, ANALYZED, AND DETERMINED TO BE

NON-ASBESTOS.

5. ESTABLISH REGULATED AREAS (RA) AND NEGATIVE PRESSURE ENCLOSURES (NPE) AND PERFORM REMOVAL IN ACCORDANCE WITH APPLICABLE SPECIFICATION SECTIONS: SEC 02 82 13-13, GLOVEBAG ASBESTOS ABATEMENT; SEC 02 82 11, TRADITIONAL

ASBESTOS ABATEMENT; SEC 02 82 13-19, ASBESTOS FLOOR TILE AND MASTIC ABATEMENT.

6. FINALIZE LIMITS OF REGULATED AREAS, LOCATIONS OF NEGATIVE AIR MACHINES (NAM), PERSONAL DECONTAMINATION FACILITIES (PDF), AND WASTE DECONTAMINATION FACILITIES (WDF) BASED ON SITE CONDITIONS, BEST PRACTICES AND

PHASING REQUIREMENTS.

7. ASSUME 50% EFFICIENCY WHEN CALCULATING NAM REQUIREMENTS FOR ACHIEVING FOUR (4) AIR CHANGES PER HOUR AND PROVIDED GREATER THAN -0.02” WCG PRESSURE. CONFIGURE AND PLACE NAMS AS NEEDED TO MAXIMIZE AIR MOVEMENT AND PREVENT DEAD AIR SPACE. COORDINATE NEGATIVE AIR DISCHARGE LOCATIONS WITH GENERAL CONTRACTOR, OWNER'S

REPRESENTATIVE, AND VPIH, IF NEEDED.

ASBESTOS ABATEMENT PHASING:

1. THE ABATEMENT CONTRACTOR SHALL WORK CLOSELY WITH THE GENERAL CONTRACTOR, CONTRACTING OFFICER, OWNER OR OWNER'S REPRESENTATIVE, AND/OR THE VPIH TO COORDINATE REMOVAL OF ACM IN ACCORDANCE WITH PROJECT SCHEDULING, SEQUENCING, AND PHASING REQUIREMENTS. SOME AFTER HOURS AND WEEK-END WORK MAY BE REQUIRED.

PHASING IS SUBJECT TO CHANGE TO ACCOMMODATE SITE CONDITIONS AND FACILITY OPERATIONS.

CL MET

TRUE

NORTH

PLAN

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

636A-21-701EHRM INFRASTRUCTURE

UPGRADES

GRAND ISLAND, NE

Alesia Architecture P.C.

3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941

Shaffer Stevens & Schaap P.C.

9910 North 48th Street Omaha, Nebraska 68152 Phone: (402) 455-7698

Specialized Engineering Solutions 10360 Ellison Circle Omaha, NE 68134 Phone: (402) 991-5520

IMEG Corp.

2882 106th Street Des Moines, IA 50322 Phone (515) 334-4324

Thompson, Dreessen & Dorner, Inc.

10836 Old Mill Rd Omaha, NE 68154 Phone: (402) 330-8860

AMI Environmental Inc 8802 S 135th Street Omaha, NE 68138 Phone: (402) 397-5001

3 4

10 11

6 191

KEYPLAN

BI

M

-1

6a -2

1-

- V

A G ra nd

Is la nd E

H R

M /6

_2

1_ Bl dg

1.

rv t 3/

/2

:3

3:

A M

1-HA102

SECOND FLOOR – HAZARDOUS

MATERIALS - ASBESTOS – BLDG 1 1

Revisions: Date:

CONSTRUCTION

20 21 22 23 24 25 26 27 28

A

B

C

D

E

F

G

H

J

K

L

M

N

P

R

S

T

U

V

W

X

Y

Z

AA

BB

CC

DD

NUTRISH

SE301

1-BED

SE302

HAND

WASH

ALCOVE

SE303

2-BED

SE304

2-BED

SE305

STORAGE

SE306 2-BED

SE307

1-BED

SE308

LIFT

SE309

NURSE

SE310

MEDS

SE311

STAIR

SE160

DUMBWAITER

S301

1-BED

S302

1-BED

ISOLATION

S303

1-BED

S304

Room S305

TUB/SHOWER

S306

HANDWASH

S307

CLEAN

STORAGE

S308

ALCOVE

S309

PATIENT

LOUNGE

S310

CLC

REHAB

RM

S311

UNISEX

TOILET

S312

SUPPLY

RM

SW312

SOILED

UTILITY

S314

HANDWASH

S315

2-BED

S316

2-BED

S317

LIFT

S313

NURSE

SW301

2-BED

SW302

2-BED

SW303

2-BED

SW304

2-BED

SW305

2-BED

SW306

2-BED

SW307

2-BED

SW309

ALCOVE

SW310

1-BED

SW311

OBSERVATION

SW313

HANDWASH

SW314

STAIR

NO-2

SPD

C301

CENTRAL

NURSE

C302

RN

OFFICE

C303A

LAUNDRY

C304

HSKP

C305

COMM

C306

WOMENS

TOILET

C307

MENS

TOILET

C308

NURSE

OFFICE

C309

ASSISTED

DINING

RM

C310

STAFF

LOUNGE

C311

CONFERENCE

RM

C312

PHYSICIAN/NURSE

OFFICE

C313

SOCIAL

WORKER

OFFICE

C314

MECH

C315

PHARMACIST

OFFICE

C316

NURSE

MGR

OFFICE

C317

PHYSICIAN

OFFICE

C318

SOCIAL

WORKER

C319

UNISEX

TOILET

C320

FAMILY

RM

C321

DINING

RM

C322

NUTRITION

AND

FOOD

C323

ACTIVITIES

RM

C324

REC

THERAPY

C325

CLEAN

LINEN

C326

STAIR

SE161

TOILET

C302A

ELEVATOR

LOBBY

C327

Room C330

OXYGEN

STORAGE

C305B

HALL

SE162

STAIR

NO-

SUPV

OFFICE

N3021-BED

N303

1-BED

N304

TUB/SHOWER

N305

CLEAN

STORAGE

N306

TOILET

N307

HANDWASH

N308

ALCOVE

N309

PATIENT

LOUNGE

N310

2-BED

N311

UNISEC

TOILET

N312

LIFT

N313

Room N314

Room N315

2-BED

N316 2-BED

N317

NURSE

NW301

2-BED

NW302

2-BED

NW303

2-BED

NW304

2-BED

NW305

2-BED

NW306

2-BED

NW307

HANDWASH

NW308

Room

NW309

ALCOVE

NW310

1-BED

NW311

OXYGEN

STORAGE

NW312

OBSERVATION

NW313

STAIR

SE163

FAMILY

RM

NE302

HANDWASH

ALCOVE

NE303

2-BED

NE304

2-BED

NE305

STORAGE

NE3062-BED

NE307

2-BED

NE308

LIFT

NE309

MEDS

NE310

STAIR

SE164

NURSE

SE165

1/16" = 1'-0"1 THIRD FLOOR - HAZARDOUS MATERIALS PLAN

SUMMARY OF ASBESTOS CONTAINING MATERIALS

KEY NOTE DESCRIPTION FRIABLE QTY HATCHING

1 LAMINATE FLOORING (TAN) NF 150 SF

2 DUCT MASTIC (LIGHT RED) NF 250 LF

3 12" X 12" FLOOR TILE (BEIGE) NF 150 SF

4 9" X 9" FLOOR TILE (BLACK) NF 16 SF

ASBESTOS NOTES

GENERAL NOTES:

1. THESE DRAWINGS ARE DIAGRAMMATIC AND FOR GENERAL IDENTIFICATION OF ASBESTOS-CONTAINING MATERIALS (ACM) AND LEAD-BASED PAINT (LBP) SUBJECT TO REMOVAL OR DISTURBANCE. THEIR ACCURACY IS NOT GUARANTEED. LOCATIONS AND QUANTITIES SHOWN OF ACM AND LBP TO BE REMOVED ARE REPRESENTATIVE BASED ON RECENT AND PREEXISTING SITE SURVEY INFORMATION. THE ABATEMENT CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL MATERIAL

LOCATIONS AND REMOVAL QUANTITIES, AND EXISTING SITE CONDITIONS.

2. ASBESTOS REMOVAL IS BEING PERFORMED PURSUANT TO RENOVATION OF THE PROJECT AREAS. REMOVE AND DISPOSE OF ALL ACM IN ACCORDANCE WITH APPLICABLE REGULATIONS, PROJECT SPECIFICATIONS, AND THE APPROVED ASBESTOS HAZARD ABATEMENT PLAN (AHAP). IF SUSPECT ACMS ARE ENCOUNTERED DURING CONSTRUCTION AND DEMOLITION THAT ARE NOT IDENTIFIED ON THE ASBESTOS ABATEMENT DRAWINGS, STOP WORK AND CONTACT THE PROJECT MANAGER AND VPIH.

3. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL REGULATIONS; PROJECT SPECIFICATIONS, THE APPROVED WORK PLAN, AND ACCEPTED INDUSTRY PRACTICE. WHEN REQUIREMENTS OVERLAP OR CONFLICT, THE MOST STRINGENT REQUIREMENT SHALL APPLY. ALL WORK SHALL BE SUBJECT TO INSPECTION BY THE OWNER, THE OWNER'S CONSULTANTS, AND REGULATORY PERSONNEL.

4. DEMOLITION OF NON-ACM BUILDING MATERIALS MAY BE REQUIRED TO ACCESS REGULATED MATERIALS, INCLUDING, BUT NOT LIMITED TO, CABINETS, RAISED FLOORING, GYPSUM WALLBOARD, EXPANDED METAL OR WOOD LATH AND PLASTER WALLS AND CEILINGS, WALL FRAMING, CARPET, CERAMIC AND VINYL FLOOR COVERINGS, WOOD, ETC. THE ABATEMENT CONTRACTOR SHALL BE RESPONSIBLE FOR DEMOLITION OF NON-ACM MATERIALS AS NEEDED TO ACCESS REGULATED MATERIALS FOR ABATEMENT, AND FOR COORDINATING THE LIMITS OF DEMOLITION AND ABATEMENT WITH THE GENERAL CONTRACTOR.

5. ALL COSTS ASSOCIATED WITH EXPLORATORY DEMOLITION AND DEMOLITION OF NON-ACM MATERIALS NEEDED TO ACCOMPLISH ABATEMENT SHALL BE INCLUDED IN THE ABATEMENT CONTRACTOR'S LUMP SUM PRICE FOR THE PROJECT. NO ADDITIONAL

COMPENSATION SHALL BE CONSIDERED FOR THIS WORK.

ASBESTOS NOTES:

1. THE PROJECT AREA WAS RECENTLY SURVEYED FOR ACM. REFER TO THE HAZARDOUS BUILDING MATERIALS INSPECTION REPORT BY AMI ENVIRONMENTAL, DATED NOVEMBER 16, 2021 FOR MORE INFORMATION ABOUT ACMS IDENTIFIED IN THE

PROJECT AREA.

2. CONCEALED ACM PIPE INSULATION (TSI) MAY EXIST WITHIN WALLS, PIPE CHASES AND ABOVE RIGID CEILINGS. COORDINATE ACCESS WITH DEMOLITION DRAWINGS AND THE GENERAL CONTRACTOR. SOME EXPLORATORY DEMOLITION MAY BE REQUIRED

TO DETERMINE IF CONCEALED ACM IS PRESENT.

3. IF SUSPECT ACM IS DISCOVERED IN CONSTRUCTION, STOP WORK AND CONTACT GENERAL CONTRACTOR, VA

REPRESENTATIVES AND VPIH.

4. GASKETS AND PACKINGS ARE CONCEALED IN VALVES, EQUIPMENT, STEAM TRAPS, BOILERS AND FLUES AND ARE INACCESSIBLE FOR SAMPLING. GASKETS AND PACKINGS ARE ASSUMED AS ACM UNLESS SAMPLED, ANALYZED, AND DETERMINED TO BE

NON-ASBESTOS.

5. ESTABLISH REGULATED AREAS (RA) AND NEGATIVE PRESSURE ENCLOSURES (NPE) AND PERFORM REMOVAL IN ACCORDANCE WITH APPLICABLE SPECIFICATION SECTIONS: SEC 02 82 13-13, GLOVEBAG ASBESTOS ABATEMENT; SEC 02 82 11, TRADITIONAL

ASBESTOS ABATEMENT; SEC 02 82 13-19, ASBESTOS FLOOR TILE AND MASTIC ABATEMENT.

6. FINALIZE LIMITS OF REGULATED AREAS, LOCATIONS OF NEGATIVE AIR MACHINES (NAM), PERSONAL DECONTAMINATION FACILITIES (PDF), AND WASTE DECONTAMINATION FACILITIES (WDF) BASED ON SITE CONDITIONS, BEST PRACTICES AND

PHASING REQUIREMENTS.

7. ASSUME 50% EFFICIENCY WHEN CALCULATING NAM REQUIREMENTS FOR ACHIEVING FOUR (4) AIR CHANGES PER HOUR AND PROVIDED GREATER THAN -0.02” WCG PRESSURE. CONFIGURE AND PLACE NAMS AS NEEDED TO MAXIMIZE AIR MOVEMENT AND PREVENT DEAD AIR SPACE. COORDINATE NEGATIVE AIR DISCHARGE LOCATIONS WITH GENERAL CONTRACTOR, OWNER'S

REPRESENTATIVE, AND VPIH, IF NEEDED.

ASBESTOS ABATEMENT PHASING:

1. THE ABATEMENT CONTRACTOR SHALL WORK CLOSELY WITH THE GENERAL CONTRACTOR, CONTRACTING OFFICER, OWNER OR OWNER'S REPRESENTATIVE, AND/OR THE VPIH TO COORDINATE REMOVAL OF ACM IN ACCORDANCE WITH PROJECT SCHEDULING, SEQUENCING, AND PHASING REQUIREMENTS. SOME AFTER HOURS AND WEEK-END WORK MAY BE REQUIRED.

PHASING IS SUBJECT TO CHANGE TO ACCOMMODATE SITE CONDITIONS AND FACILITY OPERATIONS.

CL MET

TRUE

NORTH

PLAN

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

636A-21-701EHRM INFRASTRUCTURE

UPGRADES

GRAND ISLAND, NE

Alesia Architecture P.C.

3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941

Shaffer Stevens & Schaap P.C.

9910 North 48th Street Omaha, Nebraska 68152 Phone: (402) 455-7698

Specialized Engineering Solutions 10360 Ellison Circle Omaha, NE 68134 Phone: (402) 991-5520

IMEG Corp.

2882 106th Street Des Moines, IA 50322 Phone (515) 334-4324

Thompson, Dreessen & Dorner, Inc.

10836 Old Mill Rd Omaha, NE 68154 Phone: (402) 330-8860

AMI Environmental Inc 8802 S 135th Street Omaha, NE 68138 Phone: (402) 397-5001

3 4

10 11

6 191

KEYPLAN

BI

M

-1

6a -2

1-

- V

A G ra nd

Is la nd E

H R

M /6

_2

1_ Bl dg

1.

rv t 3/

/2

:3

5:

A M

1-HA103

THIRD FLOOR – HAZARDOUS MATERIALS -

ASBESTOS – BLDG 1 1

Revisions: Date:

CONSTRUCTION

20 21 22 23 24 25 26 27 28

A

B

C

D

E

F

G

H

J

K

L

M

N

P

R

S

T

U

V

W

X

Y

Z

AA

BB

CC

DD

WORK

SE401

Room

SE402

Room

SE403

Room

SE404

Room

SE405

Room SE406 Room

SE407

Room

SE408

Room

SE409

Room

SE410

Room

SE411

Room

SE412

STORAGE

SE400

STAIR

SE166DUMBWAITER

S401

EXAM

S402

S403

RECEPTION

CHECK

IN

S404

OFFICE

S405

WOMEN

RESTROOM

S406

BREAK

RM

S407

STORAGE

S408

GROUP

RM

S409 S410

HOUSEKEEPING

S411HOUSEKEEPING

S412

CONFERENCE

RM

S413

GROUP

RM

S414

SW401

OFFICE

SW402

OFFICE

SW403

THERAPY

RM

SW404

OFFICE

SW405

MH

STORAGE

SW406

PHARMACIST

OFFICE

SW407

OFFICE

SW408

NURSE

OFFICE

SW409

SOCIAL

WORKER

OFFICE

SW410

SOCIAL

WORKER

OFFICE

SW411

SOCIAL

WORKER

OFFFICE

SW412

OFFICE

SW413

OFFICE

SW414

STORAGE

SW415

STAIR

SE167

COPY

RM

SE168

KITCHEN

SE169

WOMENS

TOILET

C401

OFFICE

C402

EXERCISE

RM

C402A

MENS

TOILET

C403

HOMELESS

CLINIC

C404B

OFFICE

C404A

EMS

OFFICE

C404

STAIR

SE170

COMM

C404C

2-BED

N401

2-BED

N402

HOUSEKEEPING

N403

SOILED

LINEN

N404

DINING

RM

N407

N409

COPY

RM

SE171

TREATMENT

RM

N410

RECEPTION

OFFICE

N411 LAUNDRY

N412

2-BED

N413

OFFICE

N414RESTROOM

N415

OFFICE

N416

MEDICATION

NW401

1-BED

NW402

2-BED

NW404

1-BED

NW405

1-BED

NW406

1-BED

NW4071-BED

NW408

1-BED

NW409

NW410

1-BED

NW411

1-BED

NW412

1-BED

NW413

1-BED

NW414

NW416

MEETING

RM

NE400A

OFFICE

NE401

OFFICE

NE403

BREAK

RM

NE405

NE408

OFFICE

NE406

SUPPLY

NE404

OFFICE

NE402

MEETING

RM

NE400B

STAIR

SE172

STAIR

SE173

1/16" = 1'-0"1 FOURTH FLOOR - HAZARDOUS MATERIALS PLAN

SUMMARY OF ASBESTOS CONTAINING MATERIALS

KEY NOTE DESCRIPTION FRIABLE QTY HATCHING

1 LAMINATE FLOORING (TAN) NF 150 SF

2 DUCT MASTIC (LIGHT RED) NF 250 LF

3 12" X 12" FLOOR TILE (BEIGE) NF 150 SF

4 9" X 9" FLOOR TILE (BLACK) NF 16 SF

2 3

ASBESTOS NOTES

GENERAL NOTES:

1. THESE DRAWINGS ARE DIAGRAMMATIC AND FOR GENERAL IDENTIFICATION OF ASBESTOS-CONTAINING MATERIALS (ACM) AND LEAD-BASED PAINT (LBP) SUBJECT TO REMOVAL OR DISTURBANCE. THEIR ACCURACY IS NOT GUARANTEED. LOCATIONS AND QUANTITIES SHOWN OF ACM AND LBP TO BE REMOVED ARE REPRESENTATIVE BASED ON RECENT AND PREEXISTING SITE SURVEY INFORMATION. THE ABATEMENT CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL MATERIAL

LOCATIONS AND REMOVAL QUANTITIES, AND EXISTING SITE CONDITIONS.

2. ASBESTOS REMOVAL IS BEING PERFORMED PURSUANT TO RENOVATION OF THE PROJECT AREAS. REMOVE AND DISPOSE OF ALL ACM IN ACCORDANCE WITH APPLICABLE REGULATIONS, PROJECT SPECIFICATIONS, AND THE APPROVED ASBESTOS HAZARD ABATEMENT PLAN (AHAP). IF SUSPECT ACMS ARE ENCOUNTERED DURING CONSTRUCTION AND DEMOLITION THAT ARE NOT IDENTIFIED ON THE ASBESTOS ABATEMENT DRAWINGS, STOP WORK AND CONTACT THE PROJECT MANAGER AND VPIH.

3. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL REGULATIONS; PROJECT SPECIFICATIONS, THE APPROVED WORK PLAN, AND ACCEPTED INDUSTRY PRACTICE. WHEN REQUIREMENTS OVERLAP OR CONFLICT, THE MOST STRINGENT REQUIREMENT SHALL APPLY. ALL WORK SHALL BE SUBJECT TO INSPECTION BY THE OWNER, THE OWNER'S CONSULTANTS, AND REGULATORY PERSONNEL.

4. DEMOLITION OF NON-ACM BUILDING MATERIALS MAY BE REQUIRED TO ACCESS REGULATED MATERIALS, INCLUDING, BUT NOT LIMITED TO, CABINETS, RAISED FLOORING, GYPSUM WALLBOARD, EXPANDED METAL OR WOOD LATH AND PLASTER WALLS AND CEILINGS, WALL FRAMING, CARPET, CERAMIC AND VINYL FLOOR COVERINGS, WOOD, ETC. THE ABATEMENT CONTRACTOR SHALL BE RESPONSIBLE FOR DEMOLITION OF NON-ACM MATERIALS AS NEEDED TO ACCESS REGULATED MATERIALS FOR ABATEMENT, AND FOR COORDINATING THE LIMITS OF DEMOLITION AND ABATEMENT WITH THE GENERAL CONTRACTOR.

5. ALL COSTS ASSOCIATED WITH EXPLORATORY DEMOLITION AND DEMOLITION OF NON-ACM MATERIALS NEEDED TO ACCOMPLISH ABATEMENT SHALL BE INCLUDED IN THE ABATEMENT CONTRACTOR'S LUMP SUM PRICE FOR THE PROJECT. NO ADDITIONAL

COMPENSATION SHALL BE CONSIDERED FOR THIS WORK.

ASBESTOS NOTES:

1. THE PROJECT AREA WAS RECENTLY SURVEYED FOR ACM. REFER TO THE HAZARDOUS BUILDING MATERIALS INSPECTION REPORT BY AMI ENVIRONMENTAL, DATED NOVEMBER 16, 2021 FOR MORE INFORMATION ABOUT ACMS IDENTIFIED IN THE

PROJECT AREA.

2. CONCEALED ACM PIPE INSULATION (TSI) MAY EXIST WITHIN WALLS, PIPE CHASES AND ABOVE RIGID CEILINGS. COORDINATE ACCESS WITH DEMOLITION DRAWINGS AND THE GENERAL CONTRACTOR. SOME EXPLORATORY DEMOLITION MAY BE REQUIRED

TO DETERMINE IF CONCEALED ACM IS PRESENT.

3. IF SUSPECT ACM IS DISCOVERED IN CONSTRUCTION, STOP WORK AND CONTACT GENERAL CONTRACTOR, VA

REPRESENTATIVES AND VPIH.

4. GASKETS AND PACKINGS ARE CONCEALED IN VALVES, EQUIPMENT, STEAM TRAPS, BOILERS AND FLUES AND ARE INACCESSIBLE FOR SAMPLING. GASKETS AND PACKINGS ARE ASSUMED AS ACM UNLESS SAMPLED, ANALYZED, AND DETERMINED TO BE

NON-ASBESTOS.

5. ESTABLISH REGULATED AREAS (RA) AND NEGATIVE PRESSURE ENCLOSURES (NPE) AND PERFORM REMOVAL IN ACCORDANCE WITH APPLICABLE SPECIFICATION SECTIONS: SEC 02 82 13-13, GLOVEBAG ASBESTOS ABATEMENT; SEC 02 82 11, TRADITIONAL

ASBESTOS ABATEMENT; SEC 02 82 13-19, ASBESTOS FLOOR TILE AND MASTIC ABATEMENT.

6. FINALIZE LIMITS OF REGULATED AREAS, LOCATIONS OF NEGATIVE AIR MACHINES (NAM), PERSONAL DECONTAMINATION FACILITIES (PDF), AND WASTE DECONTAMINATION FACILITIES (WDF) BASED ON SITE CONDITIONS, BEST PRACTICES AND

PHASING REQUIREMENTS.

7. ASSUME 50% EFFICIENCY WHEN CALCULATING NAM REQUIREMENTS FOR ACHIEVING FOUR (4) AIR CHANGES PER HOUR AND PROVIDED GREATER THAN -0.02” WCG PRESSURE. CONFIGURE AND PLACE NAMS AS NEEDED TO MAXIMIZE AIR MOVEMENT AND PREVENT DEAD AIR SPACE. COORDINATE NEGATIVE AIR DISCHARGE LOCATIONS WITH GENERAL CONTRACTOR, OWNER'S

REPRESENTATIVE, AND VPIH, IF NEEDED.

ASBESTOS ABATEMENT PHASING:

1. THE ABATEMENT CONTRACTOR SHALL WORK CLOSELY WITH THE GENERAL CONTRACTOR, CONTRACTING OFFICER, OWNER OR OWNER'S REPRESENTATIVE, AND/OR THE VPIH TO COORDINATE REMOVAL OF ACM IN ACCORDANCE WITH PROJECT SCHEDULING, SEQUENCING, AND PHASING REQUIREMENTS. SOME AFTER HOURS AND WEEK-END WORK MAY BE REQUIRED.

PHASING IS SUBJECT TO CHANGE TO ACCOMMODATE SITE CONDITIONS AND FACILITY OPERATIONS.

CL MET

TRUE

NORTH

PLAN

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

636A-21-701EHRM INFRASTRUCTURE

UPGRADES

GRAND ISLAND, NE

Alesia Architecture P.C.

3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941

Shaffer Stevens & Schaap P.C.

9910 North 48th Street Omaha, Nebraska 68152 Phone: (402) 455-7698

Specialized Engineering Solutions 10360 Ellison Circle Omaha, NE 68134 Phone: (402) 991-5520

IMEG Corp.

2882 106th Street Des Moines, IA 50322 Phone (515) 334-4324

Thompson, Dreessen & Dorner, Inc.

10836 Old Mill Rd Omaha, NE 68154 Phone: (402) 330-8860

AMI Environmental Inc 8802 S 135th Street Omaha, NE 68138 Phone: (402) 397-5001

3 4

10 11

6 191

KEYPLAN

BI

M

-1

6a -2

1-

- V

A G ra nd

Is la nd E

H R

M /6

_2

1_ Bl dg

1.

rv t 3/

/2

:3

8:

A M

1-HA104

FOURTH FLOOR – HAZARDOUS

MATERIALS - ASBESTOS – BLDG 1 1

Revisions: Date:

CONSTRUCTION

42 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28

B

C

D

E

F

G

H

J

K

L

M

N

P

R

S

T

OFFICE

N501

Room N502

Room N503

Room N504

STORAGE

N505

EMPLOYEE

HEALTH

EXAM

RM

NW501

OFFICE

N507B

OFFICE

N508

SITE

MANAGERS

OFFICE

N509

EXECUTIVE

OFFICE

SE174

SITE-3

CONFERENCE

RM

N511 OFFICE

N512

OFFICE

N513A OFFICE

N513 N510

SITE-1

CONFERENCE

RM

N507

STAIR

SE175

OFFICE

NW507

STORAGE

NW502

SITE-5

CONFERENCE

RM

NW504

UNION

OFFICE

NW505

SITE-2

CONFERENCE

RM

C503 OFFICE

C502

WOMENS

TOILET

C504

VACANT

C503A

OFFICE

C513B

CPRS

OFFICE

C505B

COMPUTER

TRAINING

RM AND

CPRS

C505

HAC

C505A

STAIR

SE176 BREAK

RM

S502

STORAGE

S503

LACTATION

RM

S501

CLINICAL

DOCUMENTATION

CENTER

S515

OFFICE

S514

STORAGE

S513

S512

OFFICE

S505

SITE-4

CONFERENCE

RM

S506

MENS

TOILET

S516

WOMENS

TOILET

C501

STORAGE

C502A

STORAGE

S505A

SOILED

LINEN

CHUTE

SE177

HAC

S511EMPLOYEE

EDUCATION

STORAGE

SW508

S510

OFFICE

SW507

OFFICE

SW502EMPLOYEE

EDUCATION

CLASS

RM

SW505 OFFICE

SW504

PIV RM

S518

EXTENDED

CARE

S517

STAIR

SE178

POLICE

S508

POLICE

OFFICE

SE502

OFFFICE

SE503

POLICE

OFFICE

SE501

COMM

C506

1/16" = 1'-0"1 FIFTH FLOOR - HAZARDOUS MATERIALS PLAN

SUMMARY OF ASBESTOS CONTAINING MATERIALS

KEY NOTE DESCRIPTION FRIABLE QTY HATCHING

1 LAMINATE FLOORING (TAN) NF 150 SF

2 DUCT MASTIC (LIGHT RED) NF 250 LF

3 12" X 12" FLOOR TILE (BEIGE) NF 150 SF

4 9" X 9" FLOOR TILE (BLACK) NF 16 SF

ASBESTOS NOTES

GENERAL NOTES:

1. THESE DRAWINGS ARE DIAGRAMMATIC AND FOR GENERAL IDENTIFICATION OF ASBESTOS-CONTAINING MATERIALS (ACM) AND LEAD-BASED PAINT (LBP) SUBJECT TO REMOVAL OR DISTURBANCE. THEIR ACCURACY IS NOT GUARANTEED. LOCATIONS AND QUANTITIES SHOWN OF ACM AND LBP TO BE REMOVED ARE REPRESENTATIVE BASED ON RECENT AND PREEXISTING SITE SURVEY INFORMATION. THE ABATEMENT CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL MATERIAL

LOCATIONS AND REMOVAL QUANTITIES, AND EXISTING SITE CONDITIONS.

2. ASBESTOS REMOVAL IS BEING PERFORMED PURSUANT TO RENOVATION OF THE PROJECT AREAS. REMOVE AND DISPOSE OF ALL ACM IN ACCORDANCE WITH APPLICABLE REGULATIONS, PROJECT SPECIFICATIONS, AND THE APPROVED ASBESTOS HAZARD ABATEMENT PLAN (AHAP). IF SUSPECT ACMS ARE ENCOUNTERED DURING CONSTRUCTION AND DEMOLITION THAT ARE NOT IDENTIFIED ON THE ASBESTOS ABATEMENT DRAWINGS, STOP WORK AND CONTACT THE PROJECT MANAGER AND VPIH.

3. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL REGULATIONS; PROJECT SPECIFICATIONS, THE APPROVED WORK PLAN, AND ACCEPTED INDUSTRY PRACTICE. WHEN REQUIREMENTS OVERLAP OR CONFLICT, THE MOST STRINGENT REQUIREMENT SHALL APPLY. ALL WORK SHALL BE SUBJECT TO INSPECTION BY THE OWNER, THE OWNER'S CONSULTANTS, AND REGULATORY PERSONNEL.

4. DEMOLITION OF NON-ACM BUILDING MATERIALS MAY BE REQUIRED TO ACCESS REGULATED MATERIALS, INCLUDING, BUT NOT LIMITED TO, CABINETS, RAISED FLOORING, GYPSUM WALLBOARD, EXPANDED METAL OR WOOD LATH AND PLASTER WALLS AND CEILINGS, WALL FRAMING, CARPET, CERAMIC AND VINYL FLOOR COVERINGS, WOOD, ETC. THE ABATEMENT CONTRACTOR SHALL BE RESPONSIBLE FOR DEMOLITION OF NON-ACM MATERIALS AS NEEDED TO ACCESS REGULATED MATERIALS FOR ABATEMENT, AND FOR COORDINATING THE LIMITS OF DEMOLITION AND ABATEMENT WITH THE GENERAL CONTRACTOR.

5. ALL COSTS ASSOCIATED WITH EXPLORATORY DEMOLITION AND DEMOLITION OF NON-ACM MATERIALS NEEDED TO ACCOMPLISH ABATEMENT SHALL BE INCLUDED IN THE ABATEMENT CONTRACTOR'S LUMP SUM PRICE FOR THE PROJECT. NO ADDITIONAL

COMPENSATION SHALL BE CONSIDERED FOR THIS WORK.

ASBESTOS NOTES:

1. THE PROJECT AREA WAS RECENTLY SURVEYED FOR ACM. REFER TO THE HAZARDOUS BUILDING MATERIALS INSPECTION REPORT BY AMI ENVIRONMENTAL, DATED NOVEMBER 16, 2021 FOR MORE INFORMATION ABOUT ACMS IDENTIFIED IN THE

PROJECT AREA.

2. CONCEALED ACM PIPE INSULATION (TSI) MAY EXIST WITHIN WALLS, PIPE CHASES AND ABOVE RIGID CEILINGS. COORDINATE ACCESS WITH DEMOLITION DRAWINGS AND THE GENERAL CONTRACTOR. SOME EXPLORATORY DEMOLITION MAY BE REQUIRED

TO DETERMINE IF CONCEALED ACM IS PRESENT.

3. IF SUSPECT ACM IS DISCOVERED IN CONSTRUCTION, STOP WORK AND CONTACT GENERAL CONTRACTOR, VA

REPRESENTATIVES AND VPIH.

4. GASKETS AND PACKINGS ARE CONCEALED IN VALVES, EQUIPMENT, STEAM TRAPS, BOILERS AND FLUES AND ARE INACCESSIBLE FOR SAMPLING. GASKETS AND PACKINGS ARE ASSUMED AS ACM UNLESS SAMPLED, ANALYZED, AND DETERMINED TO BE

NON-ASBESTOS.

5. ESTABLISH REGULATED AREAS (RA) AND NEGATIVE PRESSURE ENCLOSURES (NPE) AND PERFORM REMOVAL IN ACCORDANCE WITH APPLICABLE SPECIFICATION SECTIONS: SEC 02 82 13-13, GLOVEBAG ASBESTOS ABATEMENT; SEC 02 82 11, TRADITIONAL

ASBESTOS ABATEMENT; SEC 02 82 13-19, ASBESTOS FLOOR TILE AND MASTIC ABATEMENT.

6. FINALIZE LIMITS OF REGULATED AREAS, LOCATIONS OF NEGATIVE AIR MACHINES (NAM), PERSONAL DECONTAMINATION FACILITIES (PDF), AND WASTE DECONTAMINATION FACILITIES (WDF) BASED ON SITE CONDITIONS, BEST PRACTICES AND

PHASING REQUIREMENTS.

7. ASSUME 50% EFFICIENCY WHEN CALCULATING NAM REQUIREMENTS FOR ACHIEVING FOUR (4) AIR CHANGES PER HOUR AND PROVIDED GREATER THAN -0.02” WCG PRESSURE. CONFIGURE AND PLACE NAMS AS NEEDED TO MAXIMIZE AIR MOVEMENT AND PREVENT DEAD AIR SPACE. COORDINATE NEGATIVE AIR DISCHARGE LOCATIONS WITH GENERAL CONTRACTOR, OWNER'S

REPRESENTATIVE, AND VPIH, IF NEEDED.

ASBESTOS ABATEMENT PHASING:

1. THE ABATEMENT CONTRACTOR SHALL WORK CLOSELY WITH THE GENERAL CONTRACTOR, CONTRACTING OFFICER, OWNER OR OWNER'S REPRESENTATIVE, AND/OR THE VPIH TO COORDINATE REMOVAL OF ACM IN ACCORDANCE WITH PROJECT SCHEDULING, SEQUENCING, AND PHASING REQUIREMENTS. SOME AFTER HOURS AND WEEK-END WORK MAY BE REQUIRED.

PHASING IS SUBJECT TO CHANGE TO ACCOMMODATE SITE CONDITIONS AND FACILITY OPERATIONS.

CL MET

TRUE

NORTH

PLAN

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

636A-21-701EHRM INFRASTRUCTURE

UPGRADES

GRAND ISLAND, NE

Alesia Architecture P.C.

3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941

Shaffer Stevens & Schaap P.C.

9910 North 48th Street Omaha, Nebraska 68152 Phone: (402) 455-7698

Specialized Engineering Solutions 10360 Ellison Circle Omaha, NE 68134 Phone: (402) 991-5520

IMEG Corp.

2882 106th Street Des Moines, IA 50322 Phone (515) 334-4324

Thompson, Dreessen & Dorner, Inc.

10836 Old Mill Rd Omaha, NE 68154 Phone: (402) 330-8860

AMI Environmental Inc 8802 S 135th Street Omaha, NE 68138 Phone: (402) 397-5001

3 4

10 11

6 191

KEYPLAN

BI

M

-1

6a -2

1-

- V

A G ra nd

Is la nd E

H R

M /6

_2

1_ Bl dg

1.

rv t 3/

/2

:3

9:

A M

1-HA105

FIFTH FLOOR – HAZARDOUS MATERIALS -

ASBESTOS – BLDG 1 1

Revisions: Date:

CONSTRUCTION

B

C

D

E

F

G

H

J

K

L

M

N

P

R

S

T

U

V

W

X

Y

Z

AA

BB

CC

DD

CANTEEN

OFFICE

C6

COMM

C5

MENS

TOILET

C7

WAREHOUSE

SUPPLY

RM

C8

BIO

MED

SHOP/OFFICE

C9

EEMS

STORAGE

C10

WAREHOUSE

STORAGE

C11

WAREHOUSE

STORAGE

C12

CANTEEN

STORAGE

C13

STORAGE

C14

STORAGE

C15

ER

SUPPLY

C16

C17

SUPPLY

WAREHOUSE

C18

PROSTHETICS

C19

STORAGE

C20

STAIR

NO-6

STORAGE

C17E

MECH

C17B

MECH

C21

CHILLER

RM

G03

WAREHOUSE

STORAGE

C26

WAREHOUSE

STORAGE

C27

OFFICE

N02

MIKE

SAFETY

N03

SOILED

LINEN

CHUTE

N04LOCKER

RM

N05

PAHTOLOGY

N06

OFFICE

N07

IT

OPERATORS

N08

TEL

SWITCH

N09A

N10

IT

SERVICES

N11

IT

OFFICE

N12

UNISEX

TOILET

N13 N14

WOMENS

LOCKER

N14A

IT

STORAGE

N15ALOCKER

N17

STORAGE

N18

STORAGE

C22

CRAWL

SPACE

NO.7

CRAWL

SPACE

NO.6

SERVER

RM

C01

CRAWL

SPACE

NO.8

CRAWL

SPACE

NO.9

S10

MAIL

RM

S9

MAIL

RM

OFFICE

S8

ARMORY

C23

POLICE

OFFICE

S4

FITNESS

CENTER

S6

STAIR

NO 4

SE2SE1

SPS

DISPATCH

S1 OFFICE

C24 OFFICE

S2 S3

SOILED

LINEN

S7

IT

C25

SPS

LOCKER

RM

C28

EQUIP

RM

NE3A

EQUIR

RM

NE3B

NE3

NE2

OFFFICE

NE1

MENS

TOILET

C29

WOMENS

TOILET

C30

RESTROOM

C31

1/16" = 1'-0"1 GROUND FLOOR - HAZARDOUS MATERIALS PLAN

CL MET

SUMMARY OF LEAD-BASED PAINT CONTAINING MATERIALS

DESCRIPTION CONDITION EST. QTY. HATCHING

1 RADIATOR AND PIPE PAINT (WHITE) FAIR 1 EA

20LF

2 DOOR FRAME PAINT (GRAY) GOOD 1 EA

3 DOOR FRAME PAINT (YELLOW) GOOD 2 EA

LEAD NOTES

GENERAL NOTES:

1. THESE DRAWINGS ARE DIAGRAMMATIC AND FOR GENERAL IDENTIFICATION OF ASBESTOS-CONTAINING MATERIALS (ACM) AND LEAD-BASED PAINT (LBP) SUBJECT TO REMOVAL OR DISTURBANCE. THEIR ACCURACY IS NOT GUARANTEED. LOCATIONS AND QUANTITIES SHOWN OF ACM TO BE REMOVED ARE REPRESENTATIVE BASED ON RECENT AND PREEXISTING SITE SURVEY INFORMATION. THE ABATEMENT CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL MATERIAL LOCATIONS AND REMOVAL QUANTITIES, AND EXISTING SITE

CONDITIONS.

2. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL REGULATIONS, PROJECT SPECIFICATIONS, THE APPROVED WORK PLAN, AND ACCEPTED INDUSTRY PRACTICE.

WHEN REQUIREMENTS OVERLAP OR CONFLICT, THE MOST STRINGENT REQUIREMENT SHALL APPLY. ALL WORK SHALL BE SUBJECT TO INSPECTION BY THE OWNER, THE OWNER'S CONSULTANTS, AND REGULATORY

PERSONNEL.

LEAD-BASED PAINT AND PAINT CONTAINING LEAD:

1. THE PROJECT AREA WAS RECENTLY SURVEYED FOR ACM. REFER TO THE HAZARDOUS BUILDING MATERIALS INSPECTION REPORT BY AMI ENVIRONMENTAL, DATED NOVEMBER 16, 2021, FOR MORE INFORMATION

CONCERNING THE PRESENCE OF LBP AND PCL IN THE PROJECT AREAS.

2. LEAD-BASED PAINT AND PAINT CONTAINING LEAD WERE FOUND IN THE ABOVE REFERENCED SURVEY.

LEAD-BASED PAINT (LBP) ARE PAINTS THAT CONTAIN LEAD ≥1.0 mg/m² or ≥0.5 PERCENT BY WEIGHT. PAINT CONTAINING LEAD (PCL) IS PAINT WITH A DETECTABLE LEVEL OF LEAD. LBP AND PCL ARE KNOWN TO EXIST ON MATERIALS, COMPONENTS, AND SURFACES THAT MAY BE DISTURBED, PENETRATED, REFINISHED, OR DEMOLISHED. PERFORM DEMOLITION OF MATERIALS AND COMPONENTS WITH LBP AND/OR PCL IN

ACCORDANCE WITH APPLICABLE REGULATIONS AND THE APPROVED WORK PLAN.

3. CONCEALED LBP AND/OR PAINT CONTAINING LEAD MAY BE PRESENT ON SURFACES BEHIND WALLS AND MAY BE IMPACTED FOR PENETRATIONS, OR WALL DEMOLITION. LBP DUST MUST BE CONTROLLED ACCORDING TO 29 CFR 1926.62. PERFORM CLEANUP AND DISPOSAL OF LBP DUST AND DEBRIS IN ACCORDANCE WITH APPLICABLE

WASTE DISPOSAL REGULATIONS

4. FLAKING AND PEELING LBP AND/OR PCL ON SURFACES TO REMAIN SHALL BE REMOVED AND STABILIZED USING METHODS IN ACCORDANCE WITH SECTION 02 83 33.13, LEAD-BASED PAINT REMOVAL AND DISPOSAL AND OSHA

LEAD IN CONSTRUCTION RULES, 29 CFR 1926.62.

5. REFER TO THE HAZARDOUS BUILDING MATERIALS INSPECTION REPORT BY AMI ENVIRONMENTAL, DATED NOVEMBER 16, 2021, FOR INFORMATION CONCERNING THE PRESENCE OF LBP AND PCL IN THE PROJECT AREAS.

TRUE

NORTH

PLAN

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

636A-21-701EHRM INFRASTRUCTURE

UPGRADES

GRAND ISLAND, NE

Alesia Architecture P.C.

3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941

Shaffer Stevens & Schaap P.C.

9910 North 48th Street Omaha, Nebraska 68152 Phone: (402) 455-7698

Specialized Engineering Solutions 10360 Ellison Circle Omaha, NE 68134 Phone: (402) 991-5520

IMEG Corp.

2882 106th Street Des Moines, IA 50322 Phone (515) 334-4324

Thompson, Dreessen & Dorner, Inc.

10836 Old Mill Rd Omaha, NE 68154 Phone: (402) 330-8860

AMI Environmental Inc 8802 S 135th Street Omaha, NE 68138 Phone: (402) 397-5001

3 4

10 11

6 191

KEYPLAN

BI

M

-1

6a -2

1-

- V

A G ra nd

Is la nd E

H R

M /6

_2

1_ Bl dg

1.

rv t 3/

/2

:4

0:

A M

1-HL10G

GROUND FLOOR – HAZARDOUS

MATERIALS LEAD-BASED PAINT– BLDG 1 1

Revisions: Date:

CONSTRUCTION

DOCUMENTS

9/1/2022

AutoCAD SHX Text or 0.5 PERCENT BY WEIGHT. PAINT

103 SF

TR

BATH RM STAIR

PASSAGE

IT RM

STORAGE

CRAWL SPACE

1/4" = 1'-0"1 BASEMENT - FLOOR PLAN

SUMMARY OF LEAD-BASED PAINT CONTAINING MATERIALS

DESCRIPTION CONDITION EST. QTY. HATCHING

1 RADIATOR AND PIPE PAINT (WHITE) FAIR 1 EA

20LF

2 DOOR FRAME PAINT (GRAY) GOOD 1 EA

1 1

LEAD NOTES

GENERAL NOTES:

1. THESE DRAWINGS ARE DIAGRAMMATIC AND FOR GENERAL IDENTIFICATION OF ASBESTOS-CONTAINING MATERIALS (ACM) AND LEAD-BASED PAINT (LBP) SUBJECT TO REMOVAL OR DISTURBANCE. THEIR ACCURACY IS NOT GUARANTEED. LOCATIONS AND QUANTITIES SHOWN OF ACM TO BE REMOVED ARE REPRESENTATIVE BASED ON RECENT AND PREEXISTING SITE SURVEY INFORMATION. THE ABATEMENT CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL MATERIAL LOCATIONS AND REMOVAL QUANTITIES, AND EXISTING SITE

CONDITIONS.

2. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL REGULATIONS, PROJECT SPECIFICATIONS, THE APPROVED WORK PLAN, AND ACCEPTED INDUSTRY PRACTICE.

WHEN REQUIREMENTS OVERLAP OR CONFLICT, THE MOST STRINGENT REQUIREMENT SHALL APPLY. ALL WORK SHALL BE SUBJECT TO INSPECTION BY THE OWNER, THE OWNER'S CONSULTANTS, AND REGULATORY

PERSONNEL.

LEAD-BASED PAINT AND PAINT CONTAINING LEAD:

1. THE PROJECT AREA WAS RECENTLY SURVEYED FOR ACM. REFER TO THE HAZARDOUS BUILDING MATERIALS INSPECTION REPORT BY AMI ENVIRONMENTAL, DATED NOVEMBER 16, 2021, FOR MORE INFORMATION

CONCERNING THE PRESENCE OF LBP AND PCL IN THE PROJECT AREAS.

2. LEAD-BASED PAINT AND PAINT CONTAINING LEAD WERE FOUND IN THE ABOVE REFERENCED SURVEY.

LEAD-BASED PAINT (LBP) ARE PAINTS THAT CONTAIN LEAD ≥1.0 mg/m² or ≥0.5 PERCENT BY WEIGHT. PAINT CONTAINING LEAD (PCL) IS PAINT WITH A DETECTABLE LEVEL OF LEAD. LBP AND PCL ARE KNOWN TO EXIST ON MATERIALS, COMPONENTS, AND SURFACES THAT MAY BE DISTURBED, PENETRATED, REFINISHED, OR DEMOLISHED. PERFORM DEMOLITION OF MATERIALS AND COMPONENTS WITH LBP AND/OR PCL IN

ACCORDANCE WITH APPLICABLE REGULATIONS AND THE APPROVED WORK PLAN.

3. CONCEALED LBP AND/OR PAINT CONTAINING LEAD MAY BE PRESENT ON SURFACES BEHIND WALLS AND MAY BE IMPACTED FOR PENETRATIONS, OR WALL DEMOLITION. LBP DUST MUST BE CONTROLLED ACCORDING TO 29 CFR 1926.62. PERFORM CLEANUP AND DISPOSAL OF LBP DUST AND DEBRIS IN ACCORDANCE WITH APPLICABLE

WASTE DISPOSAL REGULATIONS

4. FLAKING AND PEELING LBP AND/OR PCL ON SURFACES TO REMAIN SHALL BE REMOVED AND STABILIZED USING METHODS IN ACCORDANCE WITH SECTION 02 83 33.13, LEAD-BASED PAINT REMOVAL AND DISPOSAL AND OSHA

LEAD IN CONSTRUCTION RULES, 29 CFR 1926.62.

5. REFER TO THE HAZARDOUS BUILDING MATERIALS INSPECTION REPORT BY AMI ENVIRONMENTAL, DATED NOVEMBER 16, 2021, FOR INFORMATION CONCERNING THE PRESENCE OF LBP AND PCL IN THE PROJECT AREAS.

CL MET

TRUE

NORTH

PLAN

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

636A-21-701EHRM INFRASTRUCTURE

UPGRADES

GRAND ISLAND, NE

Alesia Architecture P.C.

3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941

Shaffer Stevens & Schaap P.C.

9910 North 48th Street Omaha, Nebraska 68152 Phone: (402) 455-7698

Specialized Engineering Solutions 10360 Ellison Circle Omaha, NE 68134 Phone: (402) 991-5520

IMEG Corp.

2882 106th Street Des Moines, IA 50322 Phone (515) 334-4324

Thompson, Dreessen & Dorner, Inc.

10836 Old Mill Rd Omaha, NE 68154 Phone: (402) 330-8860

AMI Environmental Inc 8802 S 135th Street Omaha, NE 68138 Phone: (402) 397-5001

3 4

10 11

6 191

KEYPLAN

BI

M

-1

6a -2

1-

- V

A G ra nd

Is la nd E

H R

M /6

_2

1_ Bl dg

1.

rv t 3/

/2

:4

1:

A M

6-HL100

BASEMENT – HAZARDOUS MATERIALS -

LEAD-BASED PAINT – BLDG 6 6

Revisions: Date:

CONSTRUCTION

DOCUMENTS

9/1/2022

AutoCAD SHX Text or 0.5 PERCENT BY WEIGHT. PAINT

Sheets and Views
Layout1
1-HA10G - GROUND FLOOR– HAZARDOUS MATERIALS - ASBESTOS– BLDG 1
1-HA101 - FIRST FLOOR– HAZARDOUS MATERIALS -ASBESTOS– BLDG 1
1-HA102 - SECOND FLOOR– HAZARDOUS MATERIALS - ASBESTOS– BLDG 1
1-HA103 - THIRD FLOOR– HAZARDOUS MATERIALS -ASBESTOS– BLDG 1
1-HA104 - FOURTH FLOOR– HAZARDOUS MATERIALS - ASBESTOS– BLDG 1
1-HA105 - FIFTH FLOOR– HAZARDOUS MATERIALS -ASBESTOS– BLDG 1
1-HL10G - GROUND FLOOR– HAZARDOUS MATERIALS LEAD-BASED PAINT– BLDG1
6-HL100 - BASEMENT– HAZARDOUS MATERIALS -LEAD-BASED PAINT– BLDG 6

File details come from the government source that posted it. Updated .