Attachment 5 - Hazardous Materials - Drawings.pdf
PDF 3 MB Posted
- Solicitation number
- 36C77623B0002
About this file
This document package includes hazardous materials drawings and a federal contract opportunity notice for construction services. The hazardous materials drawings depict asbestos-containing materials and lead-based paint located throughout five floors and the basement of an EHRM Infrastructure Upgrades project at the Grand Island VAMC. The project number is 636-21-701. The federal contract opportunity is for the construction of these EHRM Infrastructure Upgrades with a solicitation number of 36C77623B0002. The agency issuing this opportunity is the Department of Veterans Affairs Technology Acquisition Center located in Austin, Texas.
View the file
Other files
Show all 41
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
41 2 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
A
B
C
D
E
F
G
H
J
K
L
M
N
P
R
S
T
U
V
W
X
Y
Z
AA
BB
CC
DD
CANTEEN
OFFICE
C6
COMM
C5
MENS
TOILET
C7
WAREHOUSE
SUPPLY
RM
C8
BIO
MED
SHOP/OFFICE
C9
EEMS
STORAGE
C10
WAREHOUSE
STORAGE
C11
WAREHOUSE
STORAGE
C12
CANTEEN
STORAGE
C13
STORAGE
C14
STORAGE
C15
ER
SUPPLY
C16
C17
SUPPLY
WAREHOUSE
C18
PROSTHETICS
C19
STORAGE
C20
STAIR
NO-6
STORAGE
C17E
MECH
C17B
MECH
C21
CHILLER
RM
G03
WAREHOUSE
STORAGE
C26
WAREHOUSE
STORAGE
C27
OFFICE
N02
MIKE
SAFETY
N03
SOILED
LINEN
CHUTE
N04LOCKER
RM
N05
PAHTOLOGY
N06
OFFICE
N07
IT
OPERATORS
N08
TEL
SWITCH
N09A
N10
IT
SERVICES
N11
IT
OFFICE
N12
UNISEX
TOILET
N13 N14
WOMENS
LOCKER
N14A
IT
STORAGE
N15ALOCKER
N17
STORAGE
N18
STORAGE
C22
CRAWL
SPACE
NO.7
CRAWL
SPACE
NO.6
SERVER
RM
C01
CRAWL
SPACE
NO.8
CRAWL
SPACE
NO.9
S10
RM
S9
RM
OFFICE
S8
ARMORY
C23
POLICE
OFFICE
S4
FITNESS
CENTER
S6
STAIR
NO 4
SE2SE1
SPS
DISPATCH
S1 OFFICE
C24 OFFICE
S2 S3
SOILED
LINEN
S7
IT
C25
SPS
LOCKER
RM
C28
EQUIP
RM
NE3A
EQUIR
RM
NE3B
NE3
NE2
OFFFICE
NE1
MENS
TOILET
C29
WOMENS
TOILET
C30
RESTROOM
C31
1/16" = 1'-0"1 GROUND FLOOR - HAZARDOUS MATERIALS PLAN
SUMMARY OF ASBESTOS CONTAINING MATERIALS
KEY NOTE DESCRIPTION FRIABLE QTY HATCHING
1 LAMINATE FLOORING (TAN) NF 150 SF
2 DUCT MASTIC (LIGHT RED) NF 250 LF
3 12" X 12" FLOOR TILE (BEIGE) NF 150 SF
4 9" X 9" FLOOR TILE (BLACK) NF 16 SF
5 12" X 12" FLOOR TILE (BLACK) NF 150 SF
6 12" X 12" FLOOR TILE (BEIGE) NF 10 SF
2 2
ASBESTOS NOTES
GENERAL NOTES:
1. THESE DRAWINGS ARE DIAGRAMMATIC AND FOR GENERAL IDENTIFICATION OF ASBESTOS-CONTAINING MATERIALS (ACM) AND LEAD-BASED PAINT (LBP) SUBJECT TO REMOVAL OR DISTURBANCE. THEIR ACCURACY IS NOT GUARANTEED. LOCATIONS AND QUANTITIES SHOWN OF ACM AND LBP TO BE REMOVED ARE REPRESENTATIVE BASED ON RECENT AND PREEXISTING SITE SURVEY INFORMATION. THE ABATEMENT CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL MATERIAL
LOCATIONS AND REMOVAL QUANTITIES, AND EXISTING SITE CONDITIONS.
2. ASBESTOS REMOVAL IS BEING PERFORMED PURSUANT TO RENOVATION OF THE PROJECT AREAS. REMOVE AND DISPOSE OF ALL ACM IN ACCORDANCE WITH APPLICABLE REGULATIONS, PROJECT SPECIFICATIONS, AND THE APPROVED ASBESTOS HAZARD ABATEMENT PLAN (AHAP). IF SUSPECT ACMS ARE ENCOUNTERED DURING CONSTRUCTION AND DEMOLITION THAT ARE NOT IDENTIFIED ON THE ASBESTOS ABATEMENT DRAWINGS, STOP WORK AND CONTACT THE PROJECT MANAGER AND VPIH.
3. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL REGULATIONS; PROJECT SPECIFICATIONS, THE APPROVED WORK PLAN, AND ACCEPTED INDUSTRY PRACTICE. WHEN REQUIREMENTS OVERLAP OR CONFLICT, THE MOST STRINGENT REQUIREMENT SHALL APPLY. ALL WORK SHALL BE SUBJECT TO INSPECTION BY THE OWNER, THE OWNER'S CONSULTANTS, AND REGULATORY PERSONNEL.
4. DEMOLITION OF NON-ACM BUILDING MATERIALS MAY BE REQUIRED TO ACCESS REGULATED MATERIALS, INCLUDING, BUT NOT LIMITED TO, CABINETS, RAISED FLOORING, GYPSUM WALLBOARD, EXPANDED METAL OR WOOD LATH AND PLASTER WALLS AND CEILINGS, WALL FRAMING, CARPET, CERAMIC AND VINYL FLOOR COVERINGS, WOOD, ETC. THE ABATEMENT CONTRACTOR SHALL BE RESPONSIBLE FOR DEMOLITION OF NON-ACM MATERIALS AS NEEDED TO ACCESS REGULATED MATERIALS FOR ABATEMENT, AND FOR COORDINATING THE LIMITS OF DEMOLITION AND ABATEMENT WITH THE GENERAL CONTRACTOR.
5. ALL COSTS ASSOCIATED WITH EXPLORATORY DEMOLITION AND DEMOLITION OF NON-ACM MATERIALS NEEDED TO ACCOMPLISH ABATEMENT SHALL BE INCLUDED IN THE ABATEMENT CONTRACTOR'S LUMP SUM PRICE FOR THE PROJECT. NO ADDITIONAL
COMPENSATION SHALL BE CONSIDERED FOR THIS WORK.
ASBESTOS NOTES:
1. THE PROJECT AREA WAS RECENTLY SURVEYED FOR ACM. REFER TO THE HAZARDOUS BUILDING MATERIALS INSPECTION REPORT BY AMI ENVIRONMENTAL, DATED NOVEMBER 16, 2021 FOR MORE INFORMATION ABOUT ACMS IDENTIFIED IN THE
PROJECT AREA.
2. CONCEALED ACM PIPE INSULATION (TSI) MAY EXIST WITHIN WALLS, PIPE CHASES AND ABOVE RIGID CEILINGS. COORDINATE ACCESS WITH DEMOLITION DRAWINGS AND THE GENERAL CONTRACTOR. SOME EXPLORATORY DEMOLITION MAY BE REQUIRED
TO DETERMINE IF CONCEALED ACM IS PRESENT.
3. IF SUSPECT ACM IS DISCOVERED IN CONSTRUCTION, STOP WORK AND CONTACT GENERAL CONTRACTOR, VA
REPRESENTATIVES AND VPIH.
4. GASKETS AND PACKINGS ARE CONCEALED IN VALVES, EQUIPMENT, STEAM TRAPS, BOILERS AND FLUES AND ARE INACCESSIBLE FOR SAMPLING. GASKETS AND PACKINGS ARE ASSUMED AS ACM UNLESS SAMPLED, ANALYZED, AND DETERMINED TO BE
NON-ASBESTOS.
5. ESTABLISH REGULATED AREAS (RA) AND NEGATIVE PRESSURE ENCLOSURES (NPE) AND PERFORM REMOVAL IN ACCORDANCE WITH APPLICABLE SPECIFICATION SECTIONS: SEC 02 82 13-13, GLOVEBAG ASBESTOS ABATEMENT; SEC 02 82 11, TRADITIONAL
ASBESTOS ABATEMENT; SEC 02 82 13-19, ASBESTOS FLOOR TILE AND MASTIC ABATEMENT.
6. FINALIZE LIMITS OF REGULATED AREAS, LOCATIONS OF NEGATIVE AIR MACHINES (NAM), PERSONAL DECONTAMINATION FACILITIES (PDF), AND WASTE DECONTAMINATION FACILITIES (WDF) BASED ON SITE CONDITIONS, BEST PRACTICES AND
PHASING REQUIREMENTS.
7. ASSUME 50% EFFICIENCY WHEN CALCULATING NAM REQUIREMENTS FOR ACHIEVING FOUR (4) AIR CHANGES PER HOUR AND PROVIDED GREATER THAN -0.02” WCG PRESSURE. CONFIGURE AND PLACE NAMS AS NEEDED TO MAXIMIZE AIR MOVEMENT AND PREVENT DEAD AIR SPACE. COORDINATE NEGATIVE AIR DISCHARGE LOCATIONS WITH GENERAL CONTRACTOR, OWNER'S
REPRESENTATIVE, AND VPIH, IF NEEDED.
ASBESTOS ABATEMENT PHASING:
1. THE ABATEMENT CONTRACTOR SHALL WORK CLOSELY WITH THE GENERAL CONTRACTOR, CONTRACTING OFFICER, OWNER OR OWNER'S REPRESENTATIVE, AND/OR THE VPIH TO COORDINATE REMOVAL OF ACM IN ACCORDANCE WITH PROJECT SCHEDULING, SEQUENCING, AND PHASING REQUIREMENTS. SOME AFTER HOURS AND WEEK-END WORK MAY BE REQUIRED.
PHASING IS SUBJECT TO CHANGE TO ACCOMMODATE SITE CONDITIONS AND FACILITY OPERATIONS.
TRUE
NORTH
PLAN
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
636A-21-701EHRM INFRASTRUCTURE
UPGRADES
CONSTRUCTION
DOCUMENTS
GRAND ISLAND, NE
Alesia Architecture P.C.
3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941
Shaffer Stevens & Schaap P.C.
9910 North 48th Street Omaha, Nebraska 68152 Phone: (402) 455-7698
Specialized Engineering Solutions 10360 Ellison Circle Omaha, NE 68134 Phone: (402) 991-5520
IMEG Corp.
2882 106th Street Des Moines, IA 50322 Phone (515) 334-4324
Thompson, Dreessen & Dorner, Inc.
10836 Old Mill Rd Omaha, NE 68154 Phone: (402) 330-8860
AMI Environmental Inc 8802 S 135th Street Omaha, NE 68138 Phone: (402) 397-5001
3 4
10 11
6 191
KEYPLAN
BI
M
-1
6a -2
1-
- V
A G ra nd
Is la nd E
H R
M /6
_2
1_ Bl dg
1.
rv t 3/
/2
:3
1:
A M
1-HA10G
GROUND FLOOR – HAZARDOUS
MATERIALS - ASBESTOS – BLDG 1 1
Revisions: Date: 9/1/2022 CL MET
B
C
D
E
F
G
H
J
K
L
M
N
P
R
S
T
U
V
W
X
Y
Z
AA
BB
CC
DD
TREATMENT
NE101
SUPPLY
NE104
SOILED
NE105
OFFICE
NE106
OFFICE
NE107
HAC
NE108
LAB
NE109
CANTEEN
N102
OFFICE
N103
FEMALE
TOILET
N104
MALE
TOILET
N105
OFFICE
N106
PATIENT
EDUCATION
N107
WAITING
N112
OFFICE
N115
OFFICE
N116
CASHIER
N117
STAIR
NO-3
CLINICAL
PHARMACIST
NW101
EXAM
RM
NW102
EXAM
RM
NW103
EXAM
RM
NW104
STORAGE
NW105
EXAM
RM
NW106
EXAM
RM
NW107
EXAM
RM
NW108
CLEAN
UTILITY
NW109
SOILED
UTILITY
NW110
EXAM
RM
NW111
CLEAN
LINEN
NW112
EXAM
RM
NW113
NURSE
STATION
NW114
EXAM
RM
NW115
EXAM
RM
NW116
CLINICAL
PHARMACIST
NW117
STAIR
NO-1
TOILET
NW107A
TOILET
NW108A
TOILET
NW111A
LOBBY
COMM
C100
C101
OFFFICE
C101E
CONFERENCE
RM
C101D
FOOD
STORAGE
C32
VEG RM
C33
FREEZER
C102A
FREEZER
C102
C102B
FREEZER
C103
FREEZER
C113A
WOMENS
TOILET
C104
LINEN
CLOSET
C105
STORAGE
C106
FREEZER
C112
MALE
TOILET
C107
STORAGE
C111
WASH
RM HAC
C110
HAC
C109C108
STAIR
C34
INPATIENT
PHARMACY
SE102
IV
DISPENSING
SE103
SE104
CONFERENCE
RM
SE106
CHIEF
PHARMACY
SE107
VACANT
SE108
OFFICE
SE109
REST
RM
SE110
REST
RM
SE111
CONTROL
SUBSTANCE
SE112
PRESCRIPTIONS
SE115
PATIENT
RECIEVING
SE116
VACANT
SE117
MD
EXAM
SE118
EXAM
RM
SE119
MD
EXAM
SE120
EXAM
RM
SE121
SE122
EXAM
RM
SE124
MD
EXAM
SE125
MD
EXAM
SE126
EXAM
RM
SE127
NURSE
SE128
CLEAN
UTILITY
SE130
SOILED
UTILITY
SE131
ELIGIBILTY
SE133
NUTRITION
CLINIC
SE134
EXAM
RM
SE135
OFFICE
SE136
OFFICE
SE137
ELECTRICAL
SE138
TOILET
SE139
EXAM
RM
SE140
OFFICE
SE141
EXAM
RM
SE142
MD
EXAM
SE143
TELEHEALTH
SE144
TELEMEDICINE
SE145
SOCIAL
WORK
SE147
OFFICE
SE148
STAIR
NO-4
STAIR
NO-5
HAC
SE151
TRIAGE
SE152
SOCIAL
WORKER
SE153
MINOR
TREATMENT
SE154
CONFERENCE
RM
SE155
MALE
TOILET
S111
WOMENS
TOILET
S110
ADVOCATE
OFFICE
S109 S108
RECEPTION
SW102A
NURSE
STATION
SW103
PROVIDER
STATION
SW104
EXAM
RM
SW105
EXAM
RM
SW106
EXAM
RM
SW107
SW108
EXAM
RM
SW109SW110
EXAM
RM
SW113
EXAM
RM
SW114
TOILET
SW115A
CLINICAL
PHARMACIST
SW116
TOILET
SW117
TOILET
SW118
SW119
TREATMENT
SW102B
POLICE
AMBULANCE
ENTRANCE
SE156
Room
OUTPATIENT
PHARMACY
SE114
ACTIVE
STORAGE
SE113
PASSAGE
SE105
1/16" = 1'-0"1 FIRST FLOOR - HAZARDOUS MATERIALS PLAN
SUMMARY OF ASBESTOS CONTAINING MATERIALS
KEY NOTE DESCRIPTION FRIABLE QTY HATCHING
1 LAMINATE FLOORING (TAN) NF 150 SF
2 DUCT MASTIC (LIGHT RED) NF 250 LF
3 12" X 12" FLOOR TILE (BEIGE) NF 150 SF
4 9" X 9" FLOOR TILE (BLACK) NF 16 SF
ASBESTOS NOTES
GENERAL NOTES:
1. THESE DRAWINGS ARE DIAGRAMMATIC AND FOR GENERAL IDENTIFICATION OF ASBESTOS-CONTAINING MATERIALS (ACM) AND LEAD-BASED PAINT (LBP) SUBJECT TO REMOVAL OR DISTURBANCE. THEIR ACCURACY IS NOT GUARANTEED. LOCATIONS AND QUANTITIES SHOWN OF ACM AND LBP TO BE REMOVED ARE REPRESENTATIVE BASED ON RECENT AND PREEXISTING SITE SURVEY INFORMATION. THE ABATEMENT CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL MATERIAL
LOCATIONS AND REMOVAL QUANTITIES, AND EXISTING SITE CONDITIONS.
2. ASBESTOS REMOVAL IS BEING PERFORMED PURSUANT TO RENOVATION OF THE PROJECT AREAS. REMOVE AND DISPOSE OF ALL ACM IN ACCORDANCE WITH APPLICABLE REGULATIONS, PROJECT SPECIFICATIONS, AND THE APPROVED ASBESTOS HAZARD ABATEMENT PLAN (AHAP). IF SUSPECT ACMS ARE ENCOUNTERED DURING CONSTRUCTION AND DEMOLITION THAT ARE NOT IDENTIFIED ON THE ASBESTOS ABATEMENT DRAWINGS, STOP WORK AND CONTACT THE PROJECT MANAGER AND VPIH.
3. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL REGULATIONS; PROJECT SPECIFICATIONS, THE APPROVED WORK PLAN, AND ACCEPTED INDUSTRY PRACTICE. WHEN REQUIREMENTS OVERLAP OR CONFLICT, THE MOST STRINGENT REQUIREMENT SHALL APPLY. ALL WORK SHALL BE SUBJECT TO INSPECTION BY THE OWNER, THE OWNER'S CONSULTANTS, AND REGULATORY PERSONNEL.
4. DEMOLITION OF NON-ACM BUILDING MATERIALS MAY BE REQUIRED TO ACCESS REGULATED MATERIALS, INCLUDING, BUT NOT LIMITED TO, CABINETS, RAISED FLOORING, GYPSUM WALLBOARD, EXPANDED METAL OR WOOD LATH AND PLASTER WALLS AND CEILINGS, WALL FRAMING, CARPET, CERAMIC AND VINYL FLOOR COVERINGS, WOOD, ETC. THE ABATEMENT CONTRACTOR SHALL BE RESPONSIBLE FOR DEMOLITION OF NON-ACM MATERIALS AS NEEDED TO ACCESS REGULATED MATERIALS FOR ABATEMENT, AND FOR COORDINATING THE LIMITS OF DEMOLITION AND ABATEMENT WITH THE GENERAL CONTRACTOR.
5. ALL COSTS ASSOCIATED WITH EXPLORATORY DEMOLITION AND DEMOLITION OF NON-ACM MATERIALS NEEDED TO ACCOMPLISH ABATEMENT SHALL BE INCLUDED IN THE ABATEMENT CONTRACTOR'S LUMP SUM PRICE FOR THE PROJECT. NO ADDITIONAL
COMPENSATION SHALL BE CONSIDERED FOR THIS WORK.
ASBESTOS NOTES:
1. THE PROJECT AREA WAS RECENTLY SURVEYED FOR ACM. REFER TO THE HAZARDOUS BUILDING MATERIALS INSPECTION REPORT BY AMI ENVIRONMENTAL, DATED NOVEMBER 16, 2021 FOR MORE INFORMATION ABOUT ACMS IDENTIFIED IN THE
PROJECT AREA.
2. CONCEALED ACM PIPE INSULATION (TSI) MAY EXIST WITHIN WALLS, PIPE CHASES AND ABOVE RIGID CEILINGS. COORDINATE ACCESS WITH DEMOLITION DRAWINGS AND THE GENERAL CONTRACTOR. SOME EXPLORATORY DEMOLITION MAY BE REQUIRED
TO DETERMINE IF CONCEALED ACM IS PRESENT.
3. IF SUSPECT ACM IS DISCOVERED IN CONSTRUCTION, STOP WORK AND CONTACT GENERAL CONTRACTOR, VA
REPRESENTATIVES AND VPIH.
4. GASKETS AND PACKINGS ARE CONCEALED IN VALVES, EQUIPMENT, STEAM TRAPS, BOILERS AND FLUES AND ARE INACCESSIBLE FOR SAMPLING. GASKETS AND PACKINGS ARE ASSUMED AS ACM UNLESS SAMPLED, ANALYZED, AND DETERMINED TO BE
NON-ASBESTOS.
5. ESTABLISH REGULATED AREAS (RA) AND NEGATIVE PRESSURE ENCLOSURES (NPE) AND PERFORM REMOVAL IN ACCORDANCE WITH APPLICABLE SPECIFICATION SECTIONS: SEC 02 82 13-13, GLOVEBAG ASBESTOS ABATEMENT; SEC 02 82 11, TRADITIONAL
ASBESTOS ABATEMENT; SEC 02 82 13-19, ASBESTOS FLOOR TILE AND MASTIC ABATEMENT.
6. FINALIZE LIMITS OF REGULATED AREAS, LOCATIONS OF NEGATIVE AIR MACHINES (NAM), PERSONAL DECONTAMINATION FACILITIES (PDF), AND WASTE DECONTAMINATION FACILITIES (WDF) BASED ON SITE CONDITIONS, BEST PRACTICES AND
PHASING REQUIREMENTS.
7. ASSUME 50% EFFICIENCY WHEN CALCULATING NAM REQUIREMENTS FOR ACHIEVING FOUR (4) AIR CHANGES PER HOUR AND PROVIDED GREATER THAN -0.02” WCG PRESSURE. CONFIGURE AND PLACE NAMS AS NEEDED TO MAXIMIZE AIR MOVEMENT AND PREVENT DEAD AIR SPACE. COORDINATE NEGATIVE AIR DISCHARGE LOCATIONS WITH GENERAL CONTRACTOR, OWNER'S
REPRESENTATIVE, AND VPIH, IF NEEDED.
ASBESTOS ABATEMENT PHASING:
1. THE ABATEMENT CONTRACTOR SHALL WORK CLOSELY WITH THE GENERAL CONTRACTOR, CONTRACTING OFFICER, OWNER OR OWNER'S REPRESENTATIVE, AND/OR THE VPIH TO COORDINATE REMOVAL OF ACM IN ACCORDANCE WITH PROJECT SCHEDULING, SEQUENCING, AND PHASING REQUIREMENTS. SOME AFTER HOURS AND WEEK-END WORK MAY BE REQUIRED.
PHASING IS SUBJECT TO CHANGE TO ACCOMMODATE SITE CONDITIONS AND FACILITY OPERATIONS.
CL MET
TRUE
NORTH
PLAN
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
636A-21-701EHRM INFRASTRUCTURE
UPGRADES
GRAND ISLAND, NE
Alesia Architecture P.C.
3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941
Shaffer Stevens & Schaap P.C.
9910 North 48th Street Omaha, Nebraska 68152 Phone: (402) 455-7698
Specialized Engineering Solutions 10360 Ellison Circle Omaha, NE 68134 Phone: (402) 991-5520
IMEG Corp.
2882 106th Street Des Moines, IA 50322 Phone (515) 334-4324
Thompson, Dreessen & Dorner, Inc.
10836 Old Mill Rd Omaha, NE 68154 Phone: (402) 330-8860
AMI Environmental Inc 8802 S 135th Street Omaha, NE 68138 Phone: (402) 397-5001
3 4
10 11
6 191
KEYPLAN
BI
M
-1
6a -2
1-
- V
A G ra nd
Is la nd E
H R
M /6
_2
1_ Bl dg
1.
rv t 3/
/2
:3
2:
A M
1-HA101
FIRST FLOOR – HAZARDOUS MATERIALS -
ASBESTOS – BLDG 1 1
Revisions: Date:
CONSTRUCTION
DOCUMENTS
9/1/2022
42 5 6 7 8 9 10 11
12 13 14 15 16 17 18 19
20 21 22 23 24 25 26 27 28
A
B
C
D
E
F
G
H
J
K
L
M
N
P
R
S
T
U
V
W
X
Y
Z
AA
BB
CC
DD
LAB
SE201
ELECTRICAL
SE202
MECH
SE202A
MENS
TOILET
SE203
SE204
SE205
WOMENS
TOILET
SE206
OFFICE
SE207
OFFICE
SE208
STAIR
SE123
OFFICE
SE210
LAB
STORAGE
SE201A
S201
OFFICE
S202
TREATMENT
S203
THERAPY
S204
HVAC
S205
LOCKER
S206
LAB
STORAGE
S207
WAITING
S208STORAGE
S209
OFFICE
S211
GAIT
RM
S212
EQUIPMENT
SOTRAGE
S213
KITCHEN
S203A
CONFERENCE
RM
S206A
SOILED
UTILITY
S216
O AND
P LAB
C200
COMM
C201
CHAPEL
C202
RECREATIONAL
HALL
C203
CHAPLIN
C202B
VOL
SERVICES
C203A
VOL
SVS
KITCHEN
C203B
C207
OFFICE
C208
OFFICE
C209OFFICE
C210
OFFICE
C211
OFFICE
C212
STORAGE
C213
PT RM
C214
STAIR
NO-7
STORAGE
C202A
CLEAN
LINEN
C217
CHAPLAIN
SE149 STAIR
SE150
MECH
C220
RESTROOM
C221 STORAGE
C222
RECEPTION
N201
WAITING
RM
N202
AUDIOLOGY
N203
EXAM
N204
EXAM
N205
EXAM
N206
EXAM
N207
STAIR
SE157
HAC
N209
EXAM
N210
EXAM
N211
TOILET
NE212A
WOMENS
RESTROOM
N214
MENS
RESTROOM
N215
STORAGE
N213
AUDIIOLOGY
OFFICE
NW201
AUDIOLOGY
EXAM
NW202
AUDIOLOGY
NW203
STAIR
SE158
OFFICE
NW205
TREATMENT
RM
NW206
TREATMENT
RM
NW207
EXAM
NW208
EXAM
NW209
EXAM
NW210
STORAGE
NW211
BOOTH
SE159
NW213
TREATMENT
RM
NW205B
TOILET
NW207A
NW
205C
NW205C
SOILED
HOLD
NE201
PROCED
NE202
EXAM
NE203
EXAM
NE204
EXAM
NE205
LINEN
NE206 EXAM
NE207
EXAM
NE208
STORAGE
NE209
STAFF
NE210
SUPPLY
NE211
PROCED
NE212
WAITING
SW213A
ULTRASOUND
SW201
MECH
SW202
TOILET
SW203
X-RAY
SW204
WORK
RM
SW205
TOILET
SW206
X-RAY
SW207SW208
CONTROL
RM
SW209
BREAK
RM
SW210
X-RAY
SW211
VASCULAR
PROCEDURE
RM
SW212
CHECKING
SW213
TOILET
SW201A
1/16" = 1'-0"1 SECOND FLOOR - HAZARDOUS MATERIALS PLAN
SUMMARY OF ASBESTOS CONTAINING MATERIALS
KEY NOTE DESCRIPTION FRIABLE QTY HATCHING
1 LAMINATE FLOORING (TAN) NF 150 SF
2 DUCT MASTIC (LIGHT RED) NF 250 LF
3 12" X 12" FLOOR TILE (BEIGE) NF 150 SF
4 9" X 9" FLOOR TILE (BLACK) NF 16 SF
ASBESTOS NOTES
GENERAL NOTES:
1. THESE DRAWINGS ARE DIAGRAMMATIC AND FOR GENERAL IDENTIFICATION OF ASBESTOS-CONTAINING MATERIALS (ACM) AND LEAD-BASED PAINT (LBP) SUBJECT TO REMOVAL OR DISTURBANCE. THEIR ACCURACY IS NOT GUARANTEED. LOCATIONS AND QUANTITIES SHOWN OF ACM AND LBP TO BE REMOVED ARE REPRESENTATIVE BASED ON RECENT AND PREEXISTING SITE SURVEY INFORMATION. THE ABATEMENT CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL MATERIAL
LOCATIONS AND REMOVAL QUANTITIES, AND EXISTING SITE CONDITIONS.
2. ASBESTOS REMOVAL IS BEING PERFORMED PURSUANT TO RENOVATION OF THE PROJECT AREAS. REMOVE AND DISPOSE OF ALL ACM IN ACCORDANCE WITH APPLICABLE REGULATIONS, PROJECT SPECIFICATIONS, AND THE APPROVED ASBESTOS HAZARD ABATEMENT PLAN (AHAP). IF SUSPECT ACMS ARE ENCOUNTERED DURING CONSTRUCTION AND DEMOLITION THAT ARE NOT IDENTIFIED ON THE ASBESTOS ABATEMENT DRAWINGS, STOP WORK AND CONTACT THE PROJECT MANAGER AND VPIH.
3. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL REGULATIONS; PROJECT SPECIFICATIONS, THE APPROVED WORK PLAN, AND ACCEPTED INDUSTRY PRACTICE. WHEN REQUIREMENTS OVERLAP OR CONFLICT, THE MOST STRINGENT REQUIREMENT SHALL APPLY. ALL WORK SHALL BE SUBJECT TO INSPECTION BY THE OWNER, THE OWNER'S CONSULTANTS, AND REGULATORY PERSONNEL.
4. DEMOLITION OF NON-ACM BUILDING MATERIALS MAY BE REQUIRED TO ACCESS REGULATED MATERIALS, INCLUDING, BUT NOT LIMITED TO, CABINETS, RAISED FLOORING, GYPSUM WALLBOARD, EXPANDED METAL OR WOOD LATH AND PLASTER WALLS AND CEILINGS, WALL FRAMING, CARPET, CERAMIC AND VINYL FLOOR COVERINGS, WOOD, ETC. THE ABATEMENT CONTRACTOR SHALL BE RESPONSIBLE FOR DEMOLITION OF NON-ACM MATERIALS AS NEEDED TO ACCESS REGULATED MATERIALS FOR ABATEMENT, AND FOR COORDINATING THE LIMITS OF DEMOLITION AND ABATEMENT WITH THE GENERAL CONTRACTOR.
5. ALL COSTS ASSOCIATED WITH EXPLORATORY DEMOLITION AND DEMOLITION OF NON-ACM MATERIALS NEEDED TO ACCOMPLISH ABATEMENT SHALL BE INCLUDED IN THE ABATEMENT CONTRACTOR'S LUMP SUM PRICE FOR THE PROJECT. NO ADDITIONAL
COMPENSATION SHALL BE CONSIDERED FOR THIS WORK.
ASBESTOS NOTES:
1. THE PROJECT AREA WAS RECENTLY SURVEYED FOR ACM. REFER TO THE HAZARDOUS BUILDING MATERIALS INSPECTION REPORT BY AMI ENVIRONMENTAL, DATED NOVEMBER 16, 2021 FOR MORE INFORMATION ABOUT ACMS IDENTIFIED IN THE
PROJECT AREA.
2. CONCEALED ACM PIPE INSULATION (TSI) MAY EXIST WITHIN WALLS, PIPE CHASES AND ABOVE RIGID CEILINGS. COORDINATE ACCESS WITH DEMOLITION DRAWINGS AND THE GENERAL CONTRACTOR. SOME EXPLORATORY DEMOLITION MAY BE REQUIRED
TO DETERMINE IF CONCEALED ACM IS PRESENT.
3. IF SUSPECT ACM IS DISCOVERED IN CONSTRUCTION, STOP WORK AND CONTACT GENERAL CONTRACTOR, VA
REPRESENTATIVES AND VPIH.
4. GASKETS AND PACKINGS ARE CONCEALED IN VALVES, EQUIPMENT, STEAM TRAPS, BOILERS AND FLUES AND ARE INACCESSIBLE FOR SAMPLING. GASKETS AND PACKINGS ARE ASSUMED AS ACM UNLESS SAMPLED, ANALYZED, AND DETERMINED TO BE
NON-ASBESTOS.
5. ESTABLISH REGULATED AREAS (RA) AND NEGATIVE PRESSURE ENCLOSURES (NPE) AND PERFORM REMOVAL IN ACCORDANCE WITH APPLICABLE SPECIFICATION SECTIONS: SEC 02 82 13-13, GLOVEBAG ASBESTOS ABATEMENT; SEC 02 82 11, TRADITIONAL
ASBESTOS ABATEMENT; SEC 02 82 13-19, ASBESTOS FLOOR TILE AND MASTIC ABATEMENT.
6. FINALIZE LIMITS OF REGULATED AREAS, LOCATIONS OF NEGATIVE AIR MACHINES (NAM), PERSONAL DECONTAMINATION FACILITIES (PDF), AND WASTE DECONTAMINATION FACILITIES (WDF) BASED ON SITE CONDITIONS, BEST PRACTICES AND
PHASING REQUIREMENTS.
7. ASSUME 50% EFFICIENCY WHEN CALCULATING NAM REQUIREMENTS FOR ACHIEVING FOUR (4) AIR CHANGES PER HOUR AND PROVIDED GREATER THAN -0.02” WCG PRESSURE. CONFIGURE AND PLACE NAMS AS NEEDED TO MAXIMIZE AIR MOVEMENT AND PREVENT DEAD AIR SPACE. COORDINATE NEGATIVE AIR DISCHARGE LOCATIONS WITH GENERAL CONTRACTOR, OWNER'S
REPRESENTATIVE, AND VPIH, IF NEEDED.
ASBESTOS ABATEMENT PHASING:
1. THE ABATEMENT CONTRACTOR SHALL WORK CLOSELY WITH THE GENERAL CONTRACTOR, CONTRACTING OFFICER, OWNER OR OWNER'S REPRESENTATIVE, AND/OR THE VPIH TO COORDINATE REMOVAL OF ACM IN ACCORDANCE WITH PROJECT SCHEDULING, SEQUENCING, AND PHASING REQUIREMENTS. SOME AFTER HOURS AND WEEK-END WORK MAY BE REQUIRED.
PHASING IS SUBJECT TO CHANGE TO ACCOMMODATE SITE CONDITIONS AND FACILITY OPERATIONS.
CL MET
TRUE
NORTH
PLAN
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
636A-21-701EHRM INFRASTRUCTURE
UPGRADES
GRAND ISLAND, NE
Alesia Architecture P.C.
3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941
Shaffer Stevens & Schaap P.C.
9910 North 48th Street Omaha, Nebraska 68152 Phone: (402) 455-7698
Specialized Engineering Solutions 10360 Ellison Circle Omaha, NE 68134 Phone: (402) 991-5520
IMEG Corp.
2882 106th Street Des Moines, IA 50322 Phone (515) 334-4324
Thompson, Dreessen & Dorner, Inc.
10836 Old Mill Rd Omaha, NE 68154 Phone: (402) 330-8860
AMI Environmental Inc 8802 S 135th Street Omaha, NE 68138 Phone: (402) 397-5001
3 4
10 11
6 191
KEYPLAN
BI
M
-1
6a -2
1-
- V
A G ra nd
Is la nd E
H R
M /6
_2
1_ Bl dg
1.
rv t 3/
/2
:3
3:
A M
1-HA102
SECOND FLOOR – HAZARDOUS
MATERIALS - ASBESTOS – BLDG 1 1
Revisions: Date:
CONSTRUCTION
20 21 22 23 24 25 26 27 28
A
B
C
D
E
F
G
H
J
K
L
M
N
P
R
S
T
U
V
W
X
Y
Z
AA
BB
CC
DD
NUTRISH
SE301
1-BED
SE302
HAND
WASH
ALCOVE
SE303
2-BED
SE304
2-BED
SE305
STORAGE
SE306 2-BED
SE307
1-BED
SE308
LIFT
SE309
NURSE
SE310
MEDS
SE311
STAIR
SE160
DUMBWAITER
S301
1-BED
S302
1-BED
ISOLATION
S303
1-BED
S304
Room S305
TUB/SHOWER
S306
HANDWASH
S307
CLEAN
STORAGE
S308
ALCOVE
S309
PATIENT
LOUNGE
S310
CLC
REHAB
RM
S311
UNISEX
TOILET
S312
SUPPLY
RM
SW312
SOILED
UTILITY
S314
HANDWASH
S315
2-BED
S316
2-BED
S317
LIFT
S313
NURSE
SW301
2-BED
SW302
2-BED
SW303
2-BED
SW304
2-BED
SW305
2-BED
SW306
2-BED
SW307
2-BED
SW309
ALCOVE
SW310
1-BED
SW311
OBSERVATION
SW313
HANDWASH
SW314
STAIR
NO-2
SPD
C301
CENTRAL
NURSE
C302
RN
OFFICE
C303A
LAUNDRY
C304
HSKP
C305
COMM
C306
WOMENS
TOILET
C307
MENS
TOILET
C308
NURSE
OFFICE
C309
ASSISTED
DINING
RM
C310
STAFF
LOUNGE
C311
CONFERENCE
RM
C312
PHYSICIAN/NURSE
OFFICE
C313
SOCIAL
WORKER
OFFICE
C314
MECH
C315
PHARMACIST
OFFICE
C316
NURSE
MGR
OFFICE
C317
PHYSICIAN
OFFICE
C318
SOCIAL
WORKER
C319
UNISEX
TOILET
C320
FAMILY
RM
C321
DINING
RM
C322
NUTRITION
AND
FOOD
C323
ACTIVITIES
RM
C324
REC
THERAPY
C325
CLEAN
LINEN
C326
STAIR
SE161
TOILET
C302A
ELEVATOR
LOBBY
C327
Room C330
OXYGEN
STORAGE
C305B
HALL
SE162
STAIR
NO-
SUPV
OFFICE
N3021-BED
N303
1-BED
N304
TUB/SHOWER
N305
CLEAN
STORAGE
N306
TOILET
N307
HANDWASH
N308
ALCOVE
N309
PATIENT
LOUNGE
N310
2-BED
N311
UNISEC
TOILET
N312
LIFT
N313
Room N314
Room N315
2-BED
N316 2-BED
N317
NURSE
NW301
2-BED
NW302
2-BED
NW303
2-BED
NW304
2-BED
NW305
2-BED
NW306
2-BED
NW307
HANDWASH
NW308
Room
NW309
ALCOVE
NW310
1-BED
NW311
OXYGEN
STORAGE
NW312
OBSERVATION
NW313
STAIR
SE163
FAMILY
RM
NE302
HANDWASH
ALCOVE
NE303
2-BED
NE304
2-BED
NE305
STORAGE
NE3062-BED
NE307
2-BED
NE308
LIFT
NE309
MEDS
NE310
STAIR
SE164
NURSE
SE165
1/16" = 1'-0"1 THIRD FLOOR - HAZARDOUS MATERIALS PLAN
SUMMARY OF ASBESTOS CONTAINING MATERIALS
KEY NOTE DESCRIPTION FRIABLE QTY HATCHING
1 LAMINATE FLOORING (TAN) NF 150 SF
2 DUCT MASTIC (LIGHT RED) NF 250 LF
3 12" X 12" FLOOR TILE (BEIGE) NF 150 SF
4 9" X 9" FLOOR TILE (BLACK) NF 16 SF
ASBESTOS NOTES
GENERAL NOTES:
1. THESE DRAWINGS ARE DIAGRAMMATIC AND FOR GENERAL IDENTIFICATION OF ASBESTOS-CONTAINING MATERIALS (ACM) AND LEAD-BASED PAINT (LBP) SUBJECT TO REMOVAL OR DISTURBANCE. THEIR ACCURACY IS NOT GUARANTEED. LOCATIONS AND QUANTITIES SHOWN OF ACM AND LBP TO BE REMOVED ARE REPRESENTATIVE BASED ON RECENT AND PREEXISTING SITE SURVEY INFORMATION. THE ABATEMENT CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL MATERIAL
LOCATIONS AND REMOVAL QUANTITIES, AND EXISTING SITE CONDITIONS.
2. ASBESTOS REMOVAL IS BEING PERFORMED PURSUANT TO RENOVATION OF THE PROJECT AREAS. REMOVE AND DISPOSE OF ALL ACM IN ACCORDANCE WITH APPLICABLE REGULATIONS, PROJECT SPECIFICATIONS, AND THE APPROVED ASBESTOS HAZARD ABATEMENT PLAN (AHAP). IF SUSPECT ACMS ARE ENCOUNTERED DURING CONSTRUCTION AND DEMOLITION THAT ARE NOT IDENTIFIED ON THE ASBESTOS ABATEMENT DRAWINGS, STOP WORK AND CONTACT THE PROJECT MANAGER AND VPIH.
3. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL REGULATIONS; PROJECT SPECIFICATIONS, THE APPROVED WORK PLAN, AND ACCEPTED INDUSTRY PRACTICE. WHEN REQUIREMENTS OVERLAP OR CONFLICT, THE MOST STRINGENT REQUIREMENT SHALL APPLY. ALL WORK SHALL BE SUBJECT TO INSPECTION BY THE OWNER, THE OWNER'S CONSULTANTS, AND REGULATORY PERSONNEL.
4. DEMOLITION OF NON-ACM BUILDING MATERIALS MAY BE REQUIRED TO ACCESS REGULATED MATERIALS, INCLUDING, BUT NOT LIMITED TO, CABINETS, RAISED FLOORING, GYPSUM WALLBOARD, EXPANDED METAL OR WOOD LATH AND PLASTER WALLS AND CEILINGS, WALL FRAMING, CARPET, CERAMIC AND VINYL FLOOR COVERINGS, WOOD, ETC. THE ABATEMENT CONTRACTOR SHALL BE RESPONSIBLE FOR DEMOLITION OF NON-ACM MATERIALS AS NEEDED TO ACCESS REGULATED MATERIALS FOR ABATEMENT, AND FOR COORDINATING THE LIMITS OF DEMOLITION AND ABATEMENT WITH THE GENERAL CONTRACTOR.
5. ALL COSTS ASSOCIATED WITH EXPLORATORY DEMOLITION AND DEMOLITION OF NON-ACM MATERIALS NEEDED TO ACCOMPLISH ABATEMENT SHALL BE INCLUDED IN THE ABATEMENT CONTRACTOR'S LUMP SUM PRICE FOR THE PROJECT. NO ADDITIONAL
COMPENSATION SHALL BE CONSIDERED FOR THIS WORK.
ASBESTOS NOTES:
1. THE PROJECT AREA WAS RECENTLY SURVEYED FOR ACM. REFER TO THE HAZARDOUS BUILDING MATERIALS INSPECTION REPORT BY AMI ENVIRONMENTAL, DATED NOVEMBER 16, 2021 FOR MORE INFORMATION ABOUT ACMS IDENTIFIED IN THE
PROJECT AREA.
2. CONCEALED ACM PIPE INSULATION (TSI) MAY EXIST WITHIN WALLS, PIPE CHASES AND ABOVE RIGID CEILINGS. COORDINATE ACCESS WITH DEMOLITION DRAWINGS AND THE GENERAL CONTRACTOR. SOME EXPLORATORY DEMOLITION MAY BE REQUIRED
TO DETERMINE IF CONCEALED ACM IS PRESENT.
3. IF SUSPECT ACM IS DISCOVERED IN CONSTRUCTION, STOP WORK AND CONTACT GENERAL CONTRACTOR, VA
REPRESENTATIVES AND VPIH.
4. GASKETS AND PACKINGS ARE CONCEALED IN VALVES, EQUIPMENT, STEAM TRAPS, BOILERS AND FLUES AND ARE INACCESSIBLE FOR SAMPLING. GASKETS AND PACKINGS ARE ASSUMED AS ACM UNLESS SAMPLED, ANALYZED, AND DETERMINED TO BE
NON-ASBESTOS.
5. ESTABLISH REGULATED AREAS (RA) AND NEGATIVE PRESSURE ENCLOSURES (NPE) AND PERFORM REMOVAL IN ACCORDANCE WITH APPLICABLE SPECIFICATION SECTIONS: SEC 02 82 13-13, GLOVEBAG ASBESTOS ABATEMENT; SEC 02 82 11, TRADITIONAL
ASBESTOS ABATEMENT; SEC 02 82 13-19, ASBESTOS FLOOR TILE AND MASTIC ABATEMENT.
6. FINALIZE LIMITS OF REGULATED AREAS, LOCATIONS OF NEGATIVE AIR MACHINES (NAM), PERSONAL DECONTAMINATION FACILITIES (PDF), AND WASTE DECONTAMINATION FACILITIES (WDF) BASED ON SITE CONDITIONS, BEST PRACTICES AND
PHASING REQUIREMENTS.
7. ASSUME 50% EFFICIENCY WHEN CALCULATING NAM REQUIREMENTS FOR ACHIEVING FOUR (4) AIR CHANGES PER HOUR AND PROVIDED GREATER THAN -0.02” WCG PRESSURE. CONFIGURE AND PLACE NAMS AS NEEDED TO MAXIMIZE AIR MOVEMENT AND PREVENT DEAD AIR SPACE. COORDINATE NEGATIVE AIR DISCHARGE LOCATIONS WITH GENERAL CONTRACTOR, OWNER'S
REPRESENTATIVE, AND VPIH, IF NEEDED.
ASBESTOS ABATEMENT PHASING:
1. THE ABATEMENT CONTRACTOR SHALL WORK CLOSELY WITH THE GENERAL CONTRACTOR, CONTRACTING OFFICER, OWNER OR OWNER'S REPRESENTATIVE, AND/OR THE VPIH TO COORDINATE REMOVAL OF ACM IN ACCORDANCE WITH PROJECT SCHEDULING, SEQUENCING, AND PHASING REQUIREMENTS. SOME AFTER HOURS AND WEEK-END WORK MAY BE REQUIRED.
PHASING IS SUBJECT TO CHANGE TO ACCOMMODATE SITE CONDITIONS AND FACILITY OPERATIONS.
CL MET
TRUE
NORTH
PLAN
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
636A-21-701EHRM INFRASTRUCTURE
UPGRADES
GRAND ISLAND, NE
Alesia Architecture P.C.
3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941
Shaffer Stevens & Schaap P.C.
9910 North 48th Street Omaha, Nebraska 68152 Phone: (402) 455-7698
Specialized Engineering Solutions 10360 Ellison Circle Omaha, NE 68134 Phone: (402) 991-5520
IMEG Corp.
2882 106th Street Des Moines, IA 50322 Phone (515) 334-4324
Thompson, Dreessen & Dorner, Inc.
10836 Old Mill Rd Omaha, NE 68154 Phone: (402) 330-8860
AMI Environmental Inc 8802 S 135th Street Omaha, NE 68138 Phone: (402) 397-5001
3 4
10 11
6 191
KEYPLAN
BI
M
-1
6a -2
1-
- V
A G ra nd
Is la nd E
H R
M /6
_2
1_ Bl dg
1.
rv t 3/
/2
:3
5:
A M
1-HA103
THIRD FLOOR – HAZARDOUS MATERIALS -
ASBESTOS – BLDG 1 1
Revisions: Date:
CONSTRUCTION
20 21 22 23 24 25 26 27 28
A
B
C
D
E
F
G
H
J
K
L
M
N
P
R
S
T
U
V
W
X
Y
Z
AA
BB
CC
DD
WORK
SE401
Room
SE402
Room
SE403
Room
SE404
Room
SE405
Room SE406 Room
SE407
Room
SE408
Room
SE409
Room
SE410
Room
SE411
Room
SE412
STORAGE
SE400
STAIR
SE166DUMBWAITER
S401
EXAM
S402
S403
RECEPTION
CHECK
IN
S404
OFFICE
S405
WOMEN
RESTROOM
S406
BREAK
RM
S407
STORAGE
S408
GROUP
RM
S409 S410
HOUSEKEEPING
S411HOUSEKEEPING
S412
CONFERENCE
RM
S413
GROUP
RM
S414
SW401
OFFICE
SW402
OFFICE
SW403
THERAPY
RM
SW404
OFFICE
SW405
MH
STORAGE
SW406
PHARMACIST
OFFICE
SW407
OFFICE
SW408
NURSE
OFFICE
SW409
SOCIAL
WORKER
OFFICE
SW410
SOCIAL
WORKER
OFFICE
SW411
SOCIAL
WORKER
OFFFICE
SW412
OFFICE
SW413
OFFICE
SW414
STORAGE
SW415
STAIR
SE167
COPY
RM
SE168
KITCHEN
SE169
WOMENS
TOILET
C401
OFFICE
C402
EXERCISE
RM
C402A
MENS
TOILET
C403
HOMELESS
CLINIC
C404B
OFFICE
C404A
EMS
OFFICE
C404
STAIR
SE170
COMM
C404C
2-BED
N401
2-BED
N402
HOUSEKEEPING
N403
SOILED
LINEN
N404
DINING
RM
N407
N409
COPY
RM
SE171
TREATMENT
RM
N410
RECEPTION
OFFICE
N411 LAUNDRY
N412
2-BED
N413
OFFICE
N414RESTROOM
N415
OFFICE
N416
MEDICATION
NW401
1-BED
NW402
2-BED
NW404
1-BED
NW405
1-BED
NW406
1-BED
NW4071-BED
NW408
1-BED
NW409
NW410
1-BED
NW411
1-BED
NW412
1-BED
NW413
1-BED
NW414
NW416
MEETING
RM
NE400A
OFFICE
NE401
OFFICE
NE403
BREAK
RM
NE405
NE408
OFFICE
NE406
SUPPLY
NE404
OFFICE
NE402
MEETING
RM
NE400B
STAIR
SE172
STAIR
SE173
1/16" = 1'-0"1 FOURTH FLOOR - HAZARDOUS MATERIALS PLAN
SUMMARY OF ASBESTOS CONTAINING MATERIALS
KEY NOTE DESCRIPTION FRIABLE QTY HATCHING
1 LAMINATE FLOORING (TAN) NF 150 SF
2 DUCT MASTIC (LIGHT RED) NF 250 LF
3 12" X 12" FLOOR TILE (BEIGE) NF 150 SF
4 9" X 9" FLOOR TILE (BLACK) NF 16 SF
2 3
ASBESTOS NOTES
GENERAL NOTES:
1. THESE DRAWINGS ARE DIAGRAMMATIC AND FOR GENERAL IDENTIFICATION OF ASBESTOS-CONTAINING MATERIALS (ACM) AND LEAD-BASED PAINT (LBP) SUBJECT TO REMOVAL OR DISTURBANCE. THEIR ACCURACY IS NOT GUARANTEED. LOCATIONS AND QUANTITIES SHOWN OF ACM AND LBP TO BE REMOVED ARE REPRESENTATIVE BASED ON RECENT AND PREEXISTING SITE SURVEY INFORMATION. THE ABATEMENT CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL MATERIAL
LOCATIONS AND REMOVAL QUANTITIES, AND EXISTING SITE CONDITIONS.
2. ASBESTOS REMOVAL IS BEING PERFORMED PURSUANT TO RENOVATION OF THE PROJECT AREAS. REMOVE AND DISPOSE OF ALL ACM IN ACCORDANCE WITH APPLICABLE REGULATIONS, PROJECT SPECIFICATIONS, AND THE APPROVED ASBESTOS HAZARD ABATEMENT PLAN (AHAP). IF SUSPECT ACMS ARE ENCOUNTERED DURING CONSTRUCTION AND DEMOLITION THAT ARE NOT IDENTIFIED ON THE ASBESTOS ABATEMENT DRAWINGS, STOP WORK AND CONTACT THE PROJECT MANAGER AND VPIH.
3. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL REGULATIONS; PROJECT SPECIFICATIONS, THE APPROVED WORK PLAN, AND ACCEPTED INDUSTRY PRACTICE. WHEN REQUIREMENTS OVERLAP OR CONFLICT, THE MOST STRINGENT REQUIREMENT SHALL APPLY. ALL WORK SHALL BE SUBJECT TO INSPECTION BY THE OWNER, THE OWNER'S CONSULTANTS, AND REGULATORY PERSONNEL.
4. DEMOLITION OF NON-ACM BUILDING MATERIALS MAY BE REQUIRED TO ACCESS REGULATED MATERIALS, INCLUDING, BUT NOT LIMITED TO, CABINETS, RAISED FLOORING, GYPSUM WALLBOARD, EXPANDED METAL OR WOOD LATH AND PLASTER WALLS AND CEILINGS, WALL FRAMING, CARPET, CERAMIC AND VINYL FLOOR COVERINGS, WOOD, ETC. THE ABATEMENT CONTRACTOR SHALL BE RESPONSIBLE FOR DEMOLITION OF NON-ACM MATERIALS AS NEEDED TO ACCESS REGULATED MATERIALS FOR ABATEMENT, AND FOR COORDINATING THE LIMITS OF DEMOLITION AND ABATEMENT WITH THE GENERAL CONTRACTOR.
5. ALL COSTS ASSOCIATED WITH EXPLORATORY DEMOLITION AND DEMOLITION OF NON-ACM MATERIALS NEEDED TO ACCOMPLISH ABATEMENT SHALL BE INCLUDED IN THE ABATEMENT CONTRACTOR'S LUMP SUM PRICE FOR THE PROJECT. NO ADDITIONAL
COMPENSATION SHALL BE CONSIDERED FOR THIS WORK.
ASBESTOS NOTES:
1. THE PROJECT AREA WAS RECENTLY SURVEYED FOR ACM. REFER TO THE HAZARDOUS BUILDING MATERIALS INSPECTION REPORT BY AMI ENVIRONMENTAL, DATED NOVEMBER 16, 2021 FOR MORE INFORMATION ABOUT ACMS IDENTIFIED IN THE
PROJECT AREA.
2. CONCEALED ACM PIPE INSULATION (TSI) MAY EXIST WITHIN WALLS, PIPE CHASES AND ABOVE RIGID CEILINGS. COORDINATE ACCESS WITH DEMOLITION DRAWINGS AND THE GENERAL CONTRACTOR. SOME EXPLORATORY DEMOLITION MAY BE REQUIRED
TO DETERMINE IF CONCEALED ACM IS PRESENT.
3. IF SUSPECT ACM IS DISCOVERED IN CONSTRUCTION, STOP WORK AND CONTACT GENERAL CONTRACTOR, VA
REPRESENTATIVES AND VPIH.
4. GASKETS AND PACKINGS ARE CONCEALED IN VALVES, EQUIPMENT, STEAM TRAPS, BOILERS AND FLUES AND ARE INACCESSIBLE FOR SAMPLING. GASKETS AND PACKINGS ARE ASSUMED AS ACM UNLESS SAMPLED, ANALYZED, AND DETERMINED TO BE
NON-ASBESTOS.
5. ESTABLISH REGULATED AREAS (RA) AND NEGATIVE PRESSURE ENCLOSURES (NPE) AND PERFORM REMOVAL IN ACCORDANCE WITH APPLICABLE SPECIFICATION SECTIONS: SEC 02 82 13-13, GLOVEBAG ASBESTOS ABATEMENT; SEC 02 82 11, TRADITIONAL
ASBESTOS ABATEMENT; SEC 02 82 13-19, ASBESTOS FLOOR TILE AND MASTIC ABATEMENT.
6. FINALIZE LIMITS OF REGULATED AREAS, LOCATIONS OF NEGATIVE AIR MACHINES (NAM), PERSONAL DECONTAMINATION FACILITIES (PDF), AND WASTE DECONTAMINATION FACILITIES (WDF) BASED ON SITE CONDITIONS, BEST PRACTICES AND
PHASING REQUIREMENTS.
7. ASSUME 50% EFFICIENCY WHEN CALCULATING NAM REQUIREMENTS FOR ACHIEVING FOUR (4) AIR CHANGES PER HOUR AND PROVIDED GREATER THAN -0.02” WCG PRESSURE. CONFIGURE AND PLACE NAMS AS NEEDED TO MAXIMIZE AIR MOVEMENT AND PREVENT DEAD AIR SPACE. COORDINATE NEGATIVE AIR DISCHARGE LOCATIONS WITH GENERAL CONTRACTOR, OWNER'S
REPRESENTATIVE, AND VPIH, IF NEEDED.
ASBESTOS ABATEMENT PHASING:
1. THE ABATEMENT CONTRACTOR SHALL WORK CLOSELY WITH THE GENERAL CONTRACTOR, CONTRACTING OFFICER, OWNER OR OWNER'S REPRESENTATIVE, AND/OR THE VPIH TO COORDINATE REMOVAL OF ACM IN ACCORDANCE WITH PROJECT SCHEDULING, SEQUENCING, AND PHASING REQUIREMENTS. SOME AFTER HOURS AND WEEK-END WORK MAY BE REQUIRED.
PHASING IS SUBJECT TO CHANGE TO ACCOMMODATE SITE CONDITIONS AND FACILITY OPERATIONS.
CL MET
TRUE
NORTH
PLAN
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
636A-21-701EHRM INFRASTRUCTURE
UPGRADES
GRAND ISLAND, NE
Alesia Architecture P.C.
3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941
Shaffer Stevens & Schaap P.C.
9910 North 48th Street Omaha, Nebraska 68152 Phone: (402) 455-7698
Specialized Engineering Solutions 10360 Ellison Circle Omaha, NE 68134 Phone: (402) 991-5520
IMEG Corp.
2882 106th Street Des Moines, IA 50322 Phone (515) 334-4324
Thompson, Dreessen & Dorner, Inc.
10836 Old Mill Rd Omaha, NE 68154 Phone: (402) 330-8860
AMI Environmental Inc 8802 S 135th Street Omaha, NE 68138 Phone: (402) 397-5001
3 4
10 11
6 191
KEYPLAN
BI
M
-1
6a -2
1-
- V
A G ra nd
Is la nd E
H R
M /6
_2
1_ Bl dg
1.
rv t 3/
/2
:3
8:
A M
1-HA104
FOURTH FLOOR – HAZARDOUS
MATERIALS - ASBESTOS – BLDG 1 1
Revisions: Date:
CONSTRUCTION
42 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
B
C
D
E
F
G
H
J
K
L
M
N
P
R
S
T
OFFICE
N501
Room N502
Room N503
Room N504
STORAGE
N505
EMPLOYEE
HEALTH
EXAM
RM
NW501
OFFICE
N507B
OFFICE
N508
SITE
MANAGERS
OFFICE
N509
EXECUTIVE
OFFICE
SE174
SITE-3
CONFERENCE
RM
N511 OFFICE
N512
OFFICE
N513A OFFICE
N513 N510
SITE-1
CONFERENCE
RM
N507
STAIR
SE175
OFFICE
NW507
STORAGE
NW502
SITE-5
CONFERENCE
RM
NW504
UNION
OFFICE
NW505
SITE-2
CONFERENCE
RM
C503 OFFICE
C502
WOMENS
TOILET
C504
VACANT
C503A
OFFICE
C513B
CPRS
OFFICE
C505B
COMPUTER
TRAINING
RM AND
CPRS
C505
HAC
C505A
STAIR
SE176 BREAK
RM
S502
STORAGE
S503
LACTATION
RM
S501
CLINICAL
DOCUMENTATION
CENTER
S515
OFFICE
S514
STORAGE
S513
S512
OFFICE
S505
SITE-4
CONFERENCE
RM
S506
MENS
TOILET
S516
WOMENS
TOILET
C501
STORAGE
C502A
STORAGE
S505A
SOILED
LINEN
CHUTE
SE177
HAC
S511EMPLOYEE
EDUCATION
STORAGE
SW508
S510
OFFICE
SW507
OFFICE
SW502EMPLOYEE
EDUCATION
CLASS
RM
SW505 OFFICE
SW504
PIV RM
S518
EXTENDED
CARE
S517
STAIR
SE178
POLICE
S508
POLICE
OFFICE
SE502
OFFFICE
SE503
POLICE
OFFICE
SE501
COMM
C506
1/16" = 1'-0"1 FIFTH FLOOR - HAZARDOUS MATERIALS PLAN
SUMMARY OF ASBESTOS CONTAINING MATERIALS
KEY NOTE DESCRIPTION FRIABLE QTY HATCHING
1 LAMINATE FLOORING (TAN) NF 150 SF
2 DUCT MASTIC (LIGHT RED) NF 250 LF
3 12" X 12" FLOOR TILE (BEIGE) NF 150 SF
4 9" X 9" FLOOR TILE (BLACK) NF 16 SF
ASBESTOS NOTES
GENERAL NOTES:
1. THESE DRAWINGS ARE DIAGRAMMATIC AND FOR GENERAL IDENTIFICATION OF ASBESTOS-CONTAINING MATERIALS (ACM) AND LEAD-BASED PAINT (LBP) SUBJECT TO REMOVAL OR DISTURBANCE. THEIR ACCURACY IS NOT GUARANTEED. LOCATIONS AND QUANTITIES SHOWN OF ACM AND LBP TO BE REMOVED ARE REPRESENTATIVE BASED ON RECENT AND PREEXISTING SITE SURVEY INFORMATION. THE ABATEMENT CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL MATERIAL
LOCATIONS AND REMOVAL QUANTITIES, AND EXISTING SITE CONDITIONS.
2. ASBESTOS REMOVAL IS BEING PERFORMED PURSUANT TO RENOVATION OF THE PROJECT AREAS. REMOVE AND DISPOSE OF ALL ACM IN ACCORDANCE WITH APPLICABLE REGULATIONS, PROJECT SPECIFICATIONS, AND THE APPROVED ASBESTOS HAZARD ABATEMENT PLAN (AHAP). IF SUSPECT ACMS ARE ENCOUNTERED DURING CONSTRUCTION AND DEMOLITION THAT ARE NOT IDENTIFIED ON THE ASBESTOS ABATEMENT DRAWINGS, STOP WORK AND CONTACT THE PROJECT MANAGER AND VPIH.
3. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL REGULATIONS; PROJECT SPECIFICATIONS, THE APPROVED WORK PLAN, AND ACCEPTED INDUSTRY PRACTICE. WHEN REQUIREMENTS OVERLAP OR CONFLICT, THE MOST STRINGENT REQUIREMENT SHALL APPLY. ALL WORK SHALL BE SUBJECT TO INSPECTION BY THE OWNER, THE OWNER'S CONSULTANTS, AND REGULATORY PERSONNEL.
4. DEMOLITION OF NON-ACM BUILDING MATERIALS MAY BE REQUIRED TO ACCESS REGULATED MATERIALS, INCLUDING, BUT NOT LIMITED TO, CABINETS, RAISED FLOORING, GYPSUM WALLBOARD, EXPANDED METAL OR WOOD LATH AND PLASTER WALLS AND CEILINGS, WALL FRAMING, CARPET, CERAMIC AND VINYL FLOOR COVERINGS, WOOD, ETC. THE ABATEMENT CONTRACTOR SHALL BE RESPONSIBLE FOR DEMOLITION OF NON-ACM MATERIALS AS NEEDED TO ACCESS REGULATED MATERIALS FOR ABATEMENT, AND FOR COORDINATING THE LIMITS OF DEMOLITION AND ABATEMENT WITH THE GENERAL CONTRACTOR.
5. ALL COSTS ASSOCIATED WITH EXPLORATORY DEMOLITION AND DEMOLITION OF NON-ACM MATERIALS NEEDED TO ACCOMPLISH ABATEMENT SHALL BE INCLUDED IN THE ABATEMENT CONTRACTOR'S LUMP SUM PRICE FOR THE PROJECT. NO ADDITIONAL
COMPENSATION SHALL BE CONSIDERED FOR THIS WORK.
ASBESTOS NOTES:
1. THE PROJECT AREA WAS RECENTLY SURVEYED FOR ACM. REFER TO THE HAZARDOUS BUILDING MATERIALS INSPECTION REPORT BY AMI ENVIRONMENTAL, DATED NOVEMBER 16, 2021 FOR MORE INFORMATION ABOUT ACMS IDENTIFIED IN THE
PROJECT AREA.
2. CONCEALED ACM PIPE INSULATION (TSI) MAY EXIST WITHIN WALLS, PIPE CHASES AND ABOVE RIGID CEILINGS. COORDINATE ACCESS WITH DEMOLITION DRAWINGS AND THE GENERAL CONTRACTOR. SOME EXPLORATORY DEMOLITION MAY BE REQUIRED
TO DETERMINE IF CONCEALED ACM IS PRESENT.
3. IF SUSPECT ACM IS DISCOVERED IN CONSTRUCTION, STOP WORK AND CONTACT GENERAL CONTRACTOR, VA
REPRESENTATIVES AND VPIH.
4. GASKETS AND PACKINGS ARE CONCEALED IN VALVES, EQUIPMENT, STEAM TRAPS, BOILERS AND FLUES AND ARE INACCESSIBLE FOR SAMPLING. GASKETS AND PACKINGS ARE ASSUMED AS ACM UNLESS SAMPLED, ANALYZED, AND DETERMINED TO BE
NON-ASBESTOS.
5. ESTABLISH REGULATED AREAS (RA) AND NEGATIVE PRESSURE ENCLOSURES (NPE) AND PERFORM REMOVAL IN ACCORDANCE WITH APPLICABLE SPECIFICATION SECTIONS: SEC 02 82 13-13, GLOVEBAG ASBESTOS ABATEMENT; SEC 02 82 11, TRADITIONAL
ASBESTOS ABATEMENT; SEC 02 82 13-19, ASBESTOS FLOOR TILE AND MASTIC ABATEMENT.
6. FINALIZE LIMITS OF REGULATED AREAS, LOCATIONS OF NEGATIVE AIR MACHINES (NAM), PERSONAL DECONTAMINATION FACILITIES (PDF), AND WASTE DECONTAMINATION FACILITIES (WDF) BASED ON SITE CONDITIONS, BEST PRACTICES AND
PHASING REQUIREMENTS.
7. ASSUME 50% EFFICIENCY WHEN CALCULATING NAM REQUIREMENTS FOR ACHIEVING FOUR (4) AIR CHANGES PER HOUR AND PROVIDED GREATER THAN -0.02” WCG PRESSURE. CONFIGURE AND PLACE NAMS AS NEEDED TO MAXIMIZE AIR MOVEMENT AND PREVENT DEAD AIR SPACE. COORDINATE NEGATIVE AIR DISCHARGE LOCATIONS WITH GENERAL CONTRACTOR, OWNER'S
REPRESENTATIVE, AND VPIH, IF NEEDED.
ASBESTOS ABATEMENT PHASING:
1. THE ABATEMENT CONTRACTOR SHALL WORK CLOSELY WITH THE GENERAL CONTRACTOR, CONTRACTING OFFICER, OWNER OR OWNER'S REPRESENTATIVE, AND/OR THE VPIH TO COORDINATE REMOVAL OF ACM IN ACCORDANCE WITH PROJECT SCHEDULING, SEQUENCING, AND PHASING REQUIREMENTS. SOME AFTER HOURS AND WEEK-END WORK MAY BE REQUIRED.
PHASING IS SUBJECT TO CHANGE TO ACCOMMODATE SITE CONDITIONS AND FACILITY OPERATIONS.
CL MET
TRUE
NORTH
PLAN
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
636A-21-701EHRM INFRASTRUCTURE
UPGRADES
GRAND ISLAND, NE
Alesia Architecture P.C.
3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941
Shaffer Stevens & Schaap P.C.
9910 North 48th Street Omaha, Nebraska 68152 Phone: (402) 455-7698
Specialized Engineering Solutions 10360 Ellison Circle Omaha, NE 68134 Phone: (402) 991-5520
IMEG Corp.
2882 106th Street Des Moines, IA 50322 Phone (515) 334-4324
Thompson, Dreessen & Dorner, Inc.
10836 Old Mill Rd Omaha, NE 68154 Phone: (402) 330-8860
AMI Environmental Inc 8802 S 135th Street Omaha, NE 68138 Phone: (402) 397-5001
3 4
10 11
6 191
KEYPLAN
BI
M
-1
6a -2
1-
- V
A G ra nd
Is la nd E
H R
M /6
_2
1_ Bl dg
1.
rv t 3/
/2
:3
9:
A M
1-HA105
FIFTH FLOOR – HAZARDOUS MATERIALS -
ASBESTOS – BLDG 1 1
Revisions: Date:
CONSTRUCTION
B
C
D
E
F
G
H
J
K
L
M
N
P
R
S
T
U
V
W
X
Y
Z
AA
BB
CC
DD
CANTEEN
OFFICE
C6
COMM
C5
MENS
TOILET
C7
WAREHOUSE
SUPPLY
RM
C8
BIO
MED
SHOP/OFFICE
C9
EEMS
STORAGE
C10
WAREHOUSE
STORAGE
C11
WAREHOUSE
STORAGE
C12
CANTEEN
STORAGE
C13
STORAGE
C14
STORAGE
C15
ER
SUPPLY
C16
C17
SUPPLY
WAREHOUSE
C18
PROSTHETICS
C19
STORAGE
C20
STAIR
NO-6
STORAGE
C17E
MECH
C17B
MECH
C21
CHILLER
RM
G03
WAREHOUSE
STORAGE
C26
WAREHOUSE
STORAGE
C27
OFFICE
N02
MIKE
SAFETY
N03
SOILED
LINEN
CHUTE
N04LOCKER
RM
N05
PAHTOLOGY
N06
OFFICE
N07
IT
OPERATORS
N08
TEL
SWITCH
N09A
N10
IT
SERVICES
N11
IT
OFFICE
N12
UNISEX
TOILET
N13 N14
WOMENS
LOCKER
N14A
IT
STORAGE
N15ALOCKER
N17
STORAGE
N18
STORAGE
C22
CRAWL
SPACE
NO.7
CRAWL
SPACE
NO.6
SERVER
RM
C01
CRAWL
SPACE
NO.8
CRAWL
SPACE
NO.9
S10
RM
S9
RM
OFFICE
S8
ARMORY
C23
POLICE
OFFICE
S4
FITNESS
CENTER
S6
STAIR
NO 4
SE2SE1
SPS
DISPATCH
S1 OFFICE
C24 OFFICE
S2 S3
SOILED
LINEN
S7
IT
C25
SPS
LOCKER
RM
C28
EQUIP
RM
NE3A
EQUIR
RM
NE3B
NE3
NE2
OFFFICE
NE1
MENS
TOILET
C29
WOMENS
TOILET
C30
RESTROOM
C31
1/16" = 1'-0"1 GROUND FLOOR - HAZARDOUS MATERIALS PLAN
CL MET
SUMMARY OF LEAD-BASED PAINT CONTAINING MATERIALS
DESCRIPTION CONDITION EST. QTY. HATCHING
1 RADIATOR AND PIPE PAINT (WHITE) FAIR 1 EA
20LF
2 DOOR FRAME PAINT (GRAY) GOOD 1 EA
3 DOOR FRAME PAINT (YELLOW) GOOD 2 EA
LEAD NOTES
GENERAL NOTES:
1. THESE DRAWINGS ARE DIAGRAMMATIC AND FOR GENERAL IDENTIFICATION OF ASBESTOS-CONTAINING MATERIALS (ACM) AND LEAD-BASED PAINT (LBP) SUBJECT TO REMOVAL OR DISTURBANCE. THEIR ACCURACY IS NOT GUARANTEED. LOCATIONS AND QUANTITIES SHOWN OF ACM TO BE REMOVED ARE REPRESENTATIVE BASED ON RECENT AND PREEXISTING SITE SURVEY INFORMATION. THE ABATEMENT CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL MATERIAL LOCATIONS AND REMOVAL QUANTITIES, AND EXISTING SITE
CONDITIONS.
2. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL REGULATIONS, PROJECT SPECIFICATIONS, THE APPROVED WORK PLAN, AND ACCEPTED INDUSTRY PRACTICE.
WHEN REQUIREMENTS OVERLAP OR CONFLICT, THE MOST STRINGENT REQUIREMENT SHALL APPLY. ALL WORK SHALL BE SUBJECT TO INSPECTION BY THE OWNER, THE OWNER'S CONSULTANTS, AND REGULATORY
PERSONNEL.
LEAD-BASED PAINT AND PAINT CONTAINING LEAD:
1. THE PROJECT AREA WAS RECENTLY SURVEYED FOR ACM. REFER TO THE HAZARDOUS BUILDING MATERIALS INSPECTION REPORT BY AMI ENVIRONMENTAL, DATED NOVEMBER 16, 2021, FOR MORE INFORMATION
CONCERNING THE PRESENCE OF LBP AND PCL IN THE PROJECT AREAS.
2. LEAD-BASED PAINT AND PAINT CONTAINING LEAD WERE FOUND IN THE ABOVE REFERENCED SURVEY.
LEAD-BASED PAINT (LBP) ARE PAINTS THAT CONTAIN LEAD ≥1.0 mg/m² or ≥0.5 PERCENT BY WEIGHT. PAINT CONTAINING LEAD (PCL) IS PAINT WITH A DETECTABLE LEVEL OF LEAD. LBP AND PCL ARE KNOWN TO EXIST ON MATERIALS, COMPONENTS, AND SURFACES THAT MAY BE DISTURBED, PENETRATED, REFINISHED, OR DEMOLISHED. PERFORM DEMOLITION OF MATERIALS AND COMPONENTS WITH LBP AND/OR PCL IN
ACCORDANCE WITH APPLICABLE REGULATIONS AND THE APPROVED WORK PLAN.
3. CONCEALED LBP AND/OR PAINT CONTAINING LEAD MAY BE PRESENT ON SURFACES BEHIND WALLS AND MAY BE IMPACTED FOR PENETRATIONS, OR WALL DEMOLITION. LBP DUST MUST BE CONTROLLED ACCORDING TO 29 CFR 1926.62. PERFORM CLEANUP AND DISPOSAL OF LBP DUST AND DEBRIS IN ACCORDANCE WITH APPLICABLE
WASTE DISPOSAL REGULATIONS
4. FLAKING AND PEELING LBP AND/OR PCL ON SURFACES TO REMAIN SHALL BE REMOVED AND STABILIZED USING METHODS IN ACCORDANCE WITH SECTION 02 83 33.13, LEAD-BASED PAINT REMOVAL AND DISPOSAL AND OSHA
LEAD IN CONSTRUCTION RULES, 29 CFR 1926.62.
5. REFER TO THE HAZARDOUS BUILDING MATERIALS INSPECTION REPORT BY AMI ENVIRONMENTAL, DATED NOVEMBER 16, 2021, FOR INFORMATION CONCERNING THE PRESENCE OF LBP AND PCL IN THE PROJECT AREAS.
TRUE
NORTH
PLAN
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
636A-21-701EHRM INFRASTRUCTURE
UPGRADES
GRAND ISLAND, NE
Alesia Architecture P.C.
3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941
Shaffer Stevens & Schaap P.C.
9910 North 48th Street Omaha, Nebraska 68152 Phone: (402) 455-7698
Specialized Engineering Solutions 10360 Ellison Circle Omaha, NE 68134 Phone: (402) 991-5520
IMEG Corp.
2882 106th Street Des Moines, IA 50322 Phone (515) 334-4324
Thompson, Dreessen & Dorner, Inc.
10836 Old Mill Rd Omaha, NE 68154 Phone: (402) 330-8860
AMI Environmental Inc 8802 S 135th Street Omaha, NE 68138 Phone: (402) 397-5001
3 4
10 11
6 191
KEYPLAN
BI
M
-1
6a -2
1-
- V
A G ra nd
Is la nd E
H R
M /6
_2
1_ Bl dg
1.
rv t 3/
/2
:4
0:
A M
1-HL10G
GROUND FLOOR – HAZARDOUS
MATERIALS LEAD-BASED PAINT– BLDG 1 1
Revisions: Date:
CONSTRUCTION
DOCUMENTS
9/1/2022
AutoCAD SHX Text or 0.5 PERCENT BY WEIGHT. PAINT
103 SF
TR
BATH RM STAIR
PASSAGE
IT RM
STORAGE
CRAWL SPACE
1/4" = 1'-0"1 BASEMENT - FLOOR PLAN
SUMMARY OF LEAD-BASED PAINT CONTAINING MATERIALS
DESCRIPTION CONDITION EST. QTY. HATCHING
1 RADIATOR AND PIPE PAINT (WHITE) FAIR 1 EA
20LF
2 DOOR FRAME PAINT (GRAY) GOOD 1 EA
1 1
LEAD NOTES
GENERAL NOTES:
1. THESE DRAWINGS ARE DIAGRAMMATIC AND FOR GENERAL IDENTIFICATION OF ASBESTOS-CONTAINING MATERIALS (ACM) AND LEAD-BASED PAINT (LBP) SUBJECT TO REMOVAL OR DISTURBANCE. THEIR ACCURACY IS NOT GUARANTEED. LOCATIONS AND QUANTITIES SHOWN OF ACM TO BE REMOVED ARE REPRESENTATIVE BASED ON RECENT AND PREEXISTING SITE SURVEY INFORMATION. THE ABATEMENT CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL MATERIAL LOCATIONS AND REMOVAL QUANTITIES, AND EXISTING SITE
CONDITIONS.
2. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL REGULATIONS, PROJECT SPECIFICATIONS, THE APPROVED WORK PLAN, AND ACCEPTED INDUSTRY PRACTICE.
WHEN REQUIREMENTS OVERLAP OR CONFLICT, THE MOST STRINGENT REQUIREMENT SHALL APPLY. ALL WORK SHALL BE SUBJECT TO INSPECTION BY THE OWNER, THE OWNER'S CONSULTANTS, AND REGULATORY
PERSONNEL.
LEAD-BASED PAINT AND PAINT CONTAINING LEAD:
1. THE PROJECT AREA WAS RECENTLY SURVEYED FOR ACM. REFER TO THE HAZARDOUS BUILDING MATERIALS INSPECTION REPORT BY AMI ENVIRONMENTAL, DATED NOVEMBER 16, 2021, FOR MORE INFORMATION
CONCERNING THE PRESENCE OF LBP AND PCL IN THE PROJECT AREAS.
2. LEAD-BASED PAINT AND PAINT CONTAINING LEAD WERE FOUND IN THE ABOVE REFERENCED SURVEY.
LEAD-BASED PAINT (LBP) ARE PAINTS THAT CONTAIN LEAD ≥1.0 mg/m² or ≥0.5 PERCENT BY WEIGHT. PAINT CONTAINING LEAD (PCL) IS PAINT WITH A DETECTABLE LEVEL OF LEAD. LBP AND PCL ARE KNOWN TO EXIST ON MATERIALS, COMPONENTS, AND SURFACES THAT MAY BE DISTURBED, PENETRATED, REFINISHED, OR DEMOLISHED. PERFORM DEMOLITION OF MATERIALS AND COMPONENTS WITH LBP AND/OR PCL IN
ACCORDANCE WITH APPLICABLE REGULATIONS AND THE APPROVED WORK PLAN.
3. CONCEALED LBP AND/OR PAINT CONTAINING LEAD MAY BE PRESENT ON SURFACES BEHIND WALLS AND MAY BE IMPACTED FOR PENETRATIONS, OR WALL DEMOLITION. LBP DUST MUST BE CONTROLLED ACCORDING TO 29 CFR 1926.62. PERFORM CLEANUP AND DISPOSAL OF LBP DUST AND DEBRIS IN ACCORDANCE WITH APPLICABLE
WASTE DISPOSAL REGULATIONS
4. FLAKING AND PEELING LBP AND/OR PCL ON SURFACES TO REMAIN SHALL BE REMOVED AND STABILIZED USING METHODS IN ACCORDANCE WITH SECTION 02 83 33.13, LEAD-BASED PAINT REMOVAL AND DISPOSAL AND OSHA
LEAD IN CONSTRUCTION RULES, 29 CFR 1926.62.
5. REFER TO THE HAZARDOUS BUILDING MATERIALS INSPECTION REPORT BY AMI ENVIRONMENTAL, DATED NOVEMBER 16, 2021, FOR INFORMATION CONCERNING THE PRESENCE OF LBP AND PCL IN THE PROJECT AREAS.
CL MET
TRUE
NORTH
PLAN
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
636A-21-701EHRM INFRASTRUCTURE
UPGRADES
GRAND ISLAND, NE
Alesia Architecture P.C.
3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941
Shaffer Stevens & Schaap P.C.
9910 North 48th Street Omaha, Nebraska 68152 Phone: (402) 455-7698
Specialized Engineering Solutions 10360 Ellison Circle Omaha, NE 68134 Phone: (402) 991-5520
IMEG Corp.
2882 106th Street Des Moines, IA 50322 Phone (515) 334-4324
Thompson, Dreessen & Dorner, Inc.
10836 Old Mill Rd Omaha, NE 68154 Phone: (402) 330-8860
AMI Environmental Inc 8802 S 135th Street Omaha, NE 68138 Phone: (402) 397-5001
3 4
10 11
6 191
KEYPLAN
BI
M
-1
6a -2
1-
- V
A G ra nd
Is la nd E
H R
M /6
_2
1_ Bl dg
1.
rv t 3/
/2
:4
1:
A M
6-HL100
BASEMENT – HAZARDOUS MATERIALS -
LEAD-BASED PAINT – BLDG 6 6
Revisions: Date:
CONSTRUCTION
DOCUMENTS
9/1/2022
AutoCAD SHX Text or 0.5 PERCENT BY WEIGHT. PAINT
| Sheets and Views |
| Layout1 |
| 1-HA10G - GROUND FLOOR– HAZARDOUS MATERIALS - ASBESTOS– BLDG 1 |
| 1-HA101 - FIRST FLOOR– HAZARDOUS MATERIALS -ASBESTOS– BLDG 1 |
| 1-HA102 - SECOND FLOOR– HAZARDOUS MATERIALS - ASBESTOS– BLDG 1 |
| 1-HA103 - THIRD FLOOR– HAZARDOUS MATERIALS -ASBESTOS– BLDG 1 |
| 1-HA104 - FOURTH FLOOR– HAZARDOUS MATERIALS - ASBESTOS– BLDG 1 |
| 1-HA105 - FIFTH FLOOR– HAZARDOUS MATERIALS -ASBESTOS– BLDG 1 |
| 1-HL10G - GROUND FLOOR– HAZARDOUS MATERIALS LEAD-BASED PAINT– BLDG1 |
| 6-HL100 - BASEMENT– HAZARDOUS MATERIALS -LEAD-BASED PAINT– BLDG 6 |
File details come from the government source that posted it. Updated .