Attachment 11 - Technology - Drawings.pdf

PDF 16 MB Posted

Attached to
EHRM Infrastructure Construction Grand Island Project #636-21-701
Solicitation number
36C77623B0002
Issued by

About this file

This document provides details for a federal construction solicitation. The solicitation number 36C77623B0002 is for the Construction of the EHRM Infrastructure Upgrades at the Grand Island VAMC, Project #636-21-701, issued by the Department of Veterans Affairs Technology Acquisition Center Austin. The opportunity type is a solicitation for construction to upgrade infrastructure at the Grand Island Veterans Affairs Medical Center. An attachment to the solicitation provides construction drawings related to the project. The response due date, award date, pricing terms, and other contractual requirements are not specified in this document.

View the file

Other files

File Type Posted
36C77623B0002 0004 Amendment - Bid Opening and Wage Rates.pdf PDF
Attachment 15 - Construction Wage Rates - Hall 01-13-2022.pdf PDF
ADD 1 - 01 Reports - 1947 Original Construction A2.pdf PDF
Alesia Addendum 1.pdf PDF
ADD 1 - 02 Project Manual - 07 40 00 - ROOFING AND SIDING PANELS - Addendum 1.pdf PDF
ADD 1 - 03 Architectural - A-701.pdf PDF
ADD 1 - 01 Reports - Geotechnical Report 20220114 TD2.pdf PDF
ADD 1 - 02 Project Manual - 09 06 00 - SCHEDULE FOR FINISHES - Addendum 1.pdf PDF
ADD 1 - 03 Architectural - 19-A-102.pdf PDF
ADD 1 - 02 Project Manual - 26 32 13 - ENGINE GENERATORS - Addendum 1.pdf PDF
36C77623B0002 Amendment 0003 - Addendum 1.pdf PDF
ADD 1 - 02 Project Manual - 00 01 10 - TABLE OF CONTENTS - Addendum 1.pdf PDF
ADD 1 - 03 Architectural - A-601.pdf PDF
ADD 1 - 01 Reports - HAZMAT Report GI VA EHRM 01-10-22.pdf PDF
SES Addendum 1.pdf PDF
ADD 1 - 03 General - GI002.pdf PDF
ADD 1 - 05 ME - ME Drawings Add 01.pdf PDF
ADD 1 - 03 Architectural - 19-A-201.pdf PDF
ADD 1 - 04 Civil - C3.0.pdf PDF
ADD 1 - 04 Civil - C2.0.pdf PDF
ADD 1 - 01 Reports - 1947 Original Construction S3.pdf PDF
36C77623B0002 Grand Island EHRM - Technical Questions and Answers.pdf PDF
36C77623B0002 0001 IFB Amendment - Grand Island.pdf PDF
Site Visit Sign-in Sheet - Grand Island.pdf PDF
Questions - 36C77623B0002 Grand Island.pdf PDF
Attachment 9 - Mechanical - Drawings.pdf PDF
Attachment 5 - Hazardous Materials - Drawings.pdf PDF
Attachment 16 - Site Visit Instructions.pdf PDF
Attachment 4 - Life Safety - Drawings.pdf PDF
Attachment 1 - Specifications 1.pdf PDF
Attachment 6 - Civil - Drawings.pdf PDF
Attachment 12 - COVID-19 Safety Protocols 12-14-21.pdf PDF
Attachment 13 - Limitations on Subcontracting - Construction.pdf PDF
Attachment 15 - Construction Wage Rates - Hall 09-02-2022.pdf PDF
Attachment 2 - Specifications 2.pdf PDF
Attachment 14 - Contractor Safety - Environmental Form.pdf PDF
36C77623B0002_1.pdf PDF
Attachment 10 - Electrical - Drawings.pdf PDF
Attachment 7 - Structural - Drawings.pdf PDF
Attachment 8 - Architectural - Drawings.pdf PDF
Attachment 3 - Drawings Sheet Index.pdf PDF
Show all 41

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TECHNOLOGY SYMBOL LIST

SYMBOL: DESCRIPTION: NOTE:

EQUIPMENT

LIST ABBREV.:

#D

W

#D#V

1. 4.

WALL INFORMATION OUTLET, COMBINATION

TELEPHONE/DATA COMMUNICATION

SC-IO-W

1. 4.WALL INFORMATION OUTLET, WALL TELEPHONESC-IO-W

1.

FLOOR INFORMATION OUTLET, DATA COMMUNICATION

ONLY

SC-IO-F

#D

1. 4.

CEILING INFORMATION OUTLET, DATA

COMMUNICATION ONLY

SC-IO-C

#D

1. 4.

WALL INFORMATION OUTLET, DATA COMMUNICATION

ONLY

SC-IO-W

M 2.AC-CR2 CARD ACCESS READER WITH KEYPAD; LETTER

INDICATES AS FOLLOWS:

M = MOUNT

C - CEILING D - DESK F- FLUSH H - HIDDEN M -

MULLION

P - PEDESTAL R - RACK S - SURFACE W - WALL

CSS 2.CONTROLLED SECURITY SCHEME SCHEDULE

IDENTIFIER

N/A

CCTV 3.

VIDEO SURVEILLANCE CAMERA WITH LENS, WALL

MOUNT OR CEILING MOUNTVS-CM1

TECHNOLOGY ABBREVIATION KEY

ENTRANCE ROOMER-#

MAIN COMPUTER ROOMMCR-#

TELECOMMUNICATIONS ROOMTR-#

ABOVE FINISHED FLOORAFF

BELOW FINISHED CEILINGBFC

CONDUITC

SIMILARSIM

TYPICALTYP

MOUNTING HEIGHT ABOVE FINISHED FLOOR+#

JUNCTION BOXJ-BOX

ABBR: DESCRIPTION:

OFFICE OF INFORMATION TECHNOLOGY (VA)OIT

GENERAL NOTES:

1. ALL SYMBOLS AND ABBREVIATIONS LISTED MAY NOT BE APPLICABLE TO THIS PROJECT.

REFER TO THE TECHNOLOGY EQUIPMENT SCHEDULE FOR MORE COMPLETE DESCRIPTION

AND ITEMS.

2. ALL SYMBOLS AND ABBREVIATIONS REFER TO TECHNOLOGY SHEETS ONLY AS DEFINED ON

THE SHEET INDEX. REFER TO THE GENERAL TECHNOLOGY NOTES FOR ADDITIONAL

INFORMATION.

3. ALL SYMBOLS LISTED ABOVE ARE FOR REFERENCE ONLY. REFER TO PLANS AND LINE TYPE

KEY FOR NEW, EXISTING TO REMAIN AND TO BE REMOVED ITEMS FOR ADDITIONAL

INFORMATION.

4. REFER TO RISERS ON SHEET(S): T-500, T-501, T-502, T-503, T-504, T-505

TECHNOLOGY SYMBOL NOTES:

1. "#" INDICATES INFORMATION OUTLET FACEPLATE CONFIGURATION. REFER TO

INFORMATION OUTLET SCHEDULE ON T-600 FOR ADDITIONAL INFORMATION.

2. REFER TO CONTROLLED SECURITY SCHEME (CSS) TYPE SCHEDULE ON T-600 FOR

ADDITIONAL INFORMATION.

3. "CM-#" ON FLOOR PLANS INDICATES CAMERA TYPE AND IS ASSOCIATED WITH THE

CORRESPONDING "VS-CM-#" EQUIPMENT SCHEDULE ABBREVIATION.

4. REFER TO LINE TYPE KEY FOR NEW, EXISTING TO REMAIN, OR DEMO LINE TYPE.

CABLE TRAY, CHANNEL TRAY, BASKET

TRAY

LADDER RACK

WIDTH X HEIGHT

WIDTH X HEIGHT

DIAMETERø C CONDUIT

CONDUIT DOWN

CONDUIT UP OR UP/DOWN

CONDUIT SLEEVE

CONTINUATION

PLAN OR DETAIL NUMBER

PLAN OR DETAIL NAME

PLAN OR DETAIL SCALE

DETAIL REFERRED TO BY SECTION CUT

SHEET DETAIL IS LOCATED ON

NAME

VIEW NAME

1/8" = 1'-0"

M101

SIMSIM

INDICATES SIMILAR DETAIL REFERENCED

IN MULTIPLE LOCATIONS

LEVEL NAME

10'-0" HEIGHT ABOVE

PROJECT 0'-0"

1 INDICATES NOTE USED TO DESCRIBE

ADDITIONAL INFORMATION ABOUT

WORK REQUIRED, SPECIFIC TO THE

SHEET AND/OR DETAIL

N

O R HT

INDICATES DIRECTION OF TRUE NORTH

VIEW KEY

LINE TYPE AND TAG KEY:

NEW WORK BY THIS CONTRACTOR (WIDE LINE)

NEW

EXISTING TO BE REMOVED (SHORT DASHED PATTERN)

NEW UNDERFLOOR OR UNDERGROUND (LONG DASHED PATTERN)

EXISTING TO REMAIN OR WORK BY OTHERS (NARROW LINE)

EXISTING

EXISTING TO BE REMOVED BY OTHERS (SHORT DASHED PATTERN)

EXISTING UNDERFLOOR OR UNDERGROUND (LONG DASHED PATTERN)

HALFTONING DOES NOT MODIFY SCOPE.

'TAG'-E TAGS WITH DASH 'E' INDICATES THE REFERENCED OBJECT IS EXISTING

TAG-1 UNDERLINED TAG INDICATES OBJECT IS IN-SCOPE. IF NEW, ADDITIONAL

INFORMATION IS AVAILABLE IN A SCHEDULE, MATERIAL LIST, OR SYMBOL LIST

INDICATES AN EXISTING SYSTEM'S POINT OF CONNECTION/REMOVAL

T101

SECURITY CONTRACTORS.C.

CIVIL CONTRACTORC.C.

FIRE PROTECTION CONTRACTORF.P.C.

PLUMBING CONTRACTORP.C.

GENERAL CONTRACTORG.C.

MECHANICAL CONTRACTORM.C.

ELECTRICAL CONTRACTORE.C.

CONTRACTOR ABBREVIATION KEY

ABBR: DESCRIPTION:

TECHNOLOGY CONTRACTORT.C.

CONSTRUCTION MANAGERC.M.

SUGGESTED MATRIX OF RESPONSIBILITY

ITEM: SHOWN ON:

FURNISHED

BY:

INSTALLED

BY: NOTES:

TECHNOLOGY ROUGH-IN, REFER TO

TECHNOLOGY EQUIPMENT SCHEDULE

AND SPECIFICATIONS FOR DEFINITION

T-SERIES E.C. E.C. 3. 4.

INFORMATION OUTLET FACEPLATES,

JACKS, AND TERMINATIONS

T-SERIES T.C. T.C.

CONDUIT SLEEVES (WHEN SHOWN ON

DRAWINGS)

T-SERIES E.C. E.C.

CONDUIT SLEEVES (NOT SHOWN BUT

REQUIRED FOR PROPER INSTALLATION

OF SYSTEM)

N/A T.C. T.C. 2. 4.

TELECOMMUNICATION SYSTEMS

ROUGH-IN

T-SERIES E.C. E.C. 1.

TELECOMMUNICATION EQUIPMENT,

CABLING, AND TERMINATIONS

T-SERIES T.C. T.C.

CABLE TRAY (INCLUDING WIRE BASKET

TRAY) REFER TO SPECIFICATION

SECTION 27 05 28 FOR DEFINITION

T-SERIES E.C. E.C.

LADDER RACK T-SERIES T.C. T.C. 5.

GROUNDING LUGS ON TECHNOLOGY

EQUIPMENT

T-SERIES T.C. E.C. 6.

BONDING SYSTEM FOR TECHNOLOGY

SYSTEM, REFER TO SPECIFICATION

SECTION 27 05 26 FOR DEFINITION

T-SERIES E.C. E.C. 7. 8.

CONNECTION OF TECHNOLOGY

BONDING SYSTEM TO THE ELECTRICAL

GROUND SYSTEM

T-SERIES E.C. E.C.

LINE VOLTAGE POWER (+120V OR

GREATER)

E-SERIES E.C. E.C.

LINE VOLTAGE POWER (NOT SHOWN

BUT REQUIRED FOR PROPER

INSTALLATION OF SYSTEM)

N/A T.C. E.C. 2. 4.

LINE VOLTAGE POWER FOR DOOR

HARDWARE POWER SUPPLIES

ARCH SPEC E.C. E.C.

LOW VOLTAGE CABLING FOR

TECHNOLOGY SYSTEMS

T-SERIES T.C. T.C.

CABLE HANGERS AND SUPPORTS OR

OTHER CABLE ROUTING METHODS

(OTHER THAN CONDUIT AND CABLE

TRAY)

T-SERIES T.C. T.C. 5.

TECHNOLOGY SERVICE ENTRANCE

CONDUITS, HANDHOLES, AND

MANHOLES

T-SERIES E.C. E.C.

FLOOR BOX (ROUGH-IN) T & E SERIES E.C. E.C.

SUGGESTED MATRIX OF RESPONSIBILITY NOTES

1. LOCATIONS OF TELECOMMUNICATIONS ROUGH-INS SHALL BE INDICATED BY THE INFORMATION

OUTLET SYMBOLS ON THE DRAWINGS. REFER TO THE TECHNOLOGY SYMBOL LIST FOR

ADDITIONAL INFORMATION.

2. BASED ON THE INHERENT DIFFERENCES IN PRODUCTS FROM VARIOUS MANUFACTURERS, ALL

REQUIRED EQUIPMENT MAY NOT BE SHOWN ON THE DRAWINGS FOR ALL ACCEPTABLE

MANUFACTURERS.

3. INCLUDES BACKBOXES AND CONDUIT REQUIRED FOR THE TECHNOLOGY SYSTEMS

INSTALLATION. THE E.C. SHALL BASE THE BID ON THE BASIS OF DESIGN SHOWN ON THE

CONTRACT DOCUMENTS.

4. ALL CHANGES TO THE SLEEVES, BACKBOXES, CONDUITS, AND POWER REQUIRED BECAUSE OF

THE T.C.'S SELECTION OF AN ALTERNATE ACCEPTABLE MANUFACTURER OR FROM SYSTEM

CONFIGURATIONS THAT ARE LEFT TO THE CHOICE OF THE CONTRACTOR SHALL BE INCLUDED

IN THE T.C.'S BID. THIS BID SHALL INCLUDE INSTALLATION BY A LICENSED ELECTRICIAN.

5. UNLESS TRADE RULES DICTATE OTHERWISE.

6. FURNISHED AS PART OF THE EQUIPMENT WHEN POSSIBLE, OR FURNISHED TO THE E.C. FOR

INSTALLATION IN THE FIELD.

7. INCLUDES ALL CONDUCTORS, GROUND BARS, AND TERMINATIONS FOR THE COMPLETE

BONDING SYSTEM REQUIRED BY THE SPECIFICATIONS.

8. REFER TO ELECTRICAL DRAWINGS FOR LOCATIONS OF PANELS AND SWITCHBOARDS SHOWN

IN THE TECHNOLOGY BONDING RISER DIAGRAM AND TYPICAL TELECOM ROOM BONDING FLOW

DIAGRAM.

TELECOM ROOM REFERENCES

TELECOM ROOM

DETAIL / SHEET

REFERENCE

FLOOR PLAN

REFERENCE ARCH ROOM NUMBER

ER-01 1/1-T10G-TR-B 1-T10G N09A

MCR-01 2/1-T10G-TR-A 1-T10G 1-C01

TR-01-0 4/1-T10G-TR-B 1-T10G 1-C6

TR-01-1 1/1-T101-TR 1-T101 1-N118

TR-01-2 1/1-T102-TR 1-T102 1-S202

TR-01-3 1/1-T103-TR 1-T103 1-S302

TR-01-4 1/1-T104-TR 1-T104 1-C404A

TR-01-5 1/1-T105-TR 1-T105 1-S502

TR-03-1 1/3-T-200 3-T-100 3-2C

TR-04-1 1/4-T-200 4-T-100 4-2C

TR-05-1 1/5-T-200 5-T-100 5-1

TR-06-1 1/6-T-200 6-T-100 N/A

TR-07-1 1/7-T-200 7-T-100 104

TR-08-1 1/8-T-200 8-T-101 19

TR-17-1 3/17-T-101 17-T-101 N/A

TR-19-1 2/19-T-101 19-T-101 19-G02

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

636A-21-701

9/2/2022

EHRM INFRASTRUCTURE

UPGRADES

CONSTRUCTION

DOCUMENTS

GRAND ISLAND, NE

Alesia Architecture P.C.

3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941

Shaffer Stevens & Schaap P.C.

1070 Howard Street Omaha, NE 68102 Phone: (402) 455-7698

Specialized Engineering Solutions 10360 Ellison Circle Omaha, NE 68134 Phone: (402) 991-5520

IMEG Corp.

2882 106th Street Des Moines, IA 50322 Phone (515) 334-4324

Thompson, Dreessen & Dorner, Inc.

10836 Old Mill Rd Omaha, NE 68154 Phone: (402) 330-8860

AMI Environmental Inc 8802 S 135th Street Omaha, NE 68138 Phone: (402) 397-5001

B

IM

/2

-1 a -2

-7

V

A G ra n d I s la n d

E H

R M

/6

A

-7

.C a m p u s G e n e ra l_

T e c h

C

.r v t

/1

/2

:2

:0

P M

T-000

TECHNOLOGY COVERSHEET

PND DJJ

CAMPUS

TECHNOLOGY SHEET INDEX

T-000 TECHNOLOGY COVERSHEET

T-001 TECHNOLOGY NOTES

T-002 SITE PLAN - TECHNOLOGY

1-T-10B BASEMENT FLOOR PLAN - TECHNOLOGY - BLDG 1

1-T-10G GROUND FLOOR PLAN - TECHNOLOGY - BLDG 1

1-T-10G-TR-A GROUND FLOOR PLAN - TECHNOLOGY - ENLARGEMENTS - BLDG 1

1-T-10G-TR-B GROUND FLOOR PLAN - TECHNOLOGY - ENLARGEMENTS - BLDG 1

1-T-100A GROUND FLOOR - TECHNOLOGY - AREA A - BLDG 1

1-T-100B GROUND FLOOR - TECHNOLOGY - AREA B - BLDG 1

1-T-100C GROUND FLOOR - TECHNOLOGY - AREA C - BLDG 1

1-T-100D GROUND FLOOR - TECHNOLOGY - AREA D - BLDG 1

1-T-101 FIRST FLOOR PLAN - TECHNOLOGY - BLDG 1

1-T-101-TR FIRST FLOOR PLAN - TECHNOLOGY - ENLARGEMENTS - BLDG 1

1-T-101A FIRST FLOOR - TECHNOLOGY - AREA A - BLDG 1

1-T-101B FIRST FLOOR - TECHNOLOGY - AREA B - BLDG 1

1-T-101C FIRST FLOOR - TECHNOLOGY - AREA C - BLDG 1

1-T-101D FIRST FLOOR - TECHNOLOGY - AREA D - BLDG 1

1-T-102 SECOND FLOOR PLAN - TECHNOLOGY - BLDG 1

1-T-102-TR SECOND FLOOR PLAN - TECHNOLOGY - ENLARGEMENTS - BLDG 1

1-T-102A SECOND FLOOR - TECHNOLOGY - AREA A - BLDG 1

1-T-102B SECOND FLOOR - TECHNOLOGY - AREA B - BLDG 1

1-T-102C SECOND FLOOR - TECHNOLOGY - AREA C - BLDG 1

1-T-102D SECOND FLOOR - TECHNOLOGY - AREA D - BLDG 1

1-T-103 THIRD FLOOR PLAN - TECHNOLOGY - BLDG 1

1-T-103-TR THIRD FLOOR PLAN - TECHNOLOGY - ENLARGEMENTS - BLDG 1

1-T-103A THIRD FLOOR - TECHNOLOGY - AREA A - BLDG 1

1-T-103B THIRD FLOOR - TECHNOLOGY - AREA B - BLDG 1

1-T-103C THIRD FLOOR - TECHNOLOGY - AREA C - BLDG 1

1-T-103D THIRD FLOOR - TECHNOLOGY - AREA D - BLDG 1

1-T-104 FOURTH FLOOR PLAN - TECHNOLOGY - BLDG 1

1-T-104-TR FOURTH FLOOR - TECHNOLOGY - ENLARGEMENTS - BLDG 1

1-T-104A FOURTH FLOOR - TECHNOLOGY - AREA A - BLDG 1

1-T-104B FOURTH FLOOR - TECHNOLOGY - AREA B - BLDG 1

1-T-104C FOURTH FLOOR - TECHNOLOGY - AREA C - BLDG 1

1-T-104D FOURTH FLOOR - TECHNOLOGY - AREA D - BLDG 1

1-T-105 FIFTH FLOOR PLAN - TECHNOLOGY - BLDG 1

1-T-105-TR FIFTH FLOOR PLAN - TECHNOLOGY - ENLARGEMENTS - BLDG 1

1-T-105B FIFTH FLOOR - TECHNOLOGY - AREA B - BLDG 1

1-T-105C FIFTH FLOOR - TECHNOLOGY - AREA C - BLDG 1

1-T-106 SIXTH FLOOR PLAN - TECHNOLOGY - BLDG 1

1-T-107 SEVENTH FLOOR PLAN - TECHNOLOGY - BLDG 1

1-TD-10B BASEMENT FLOOR DEMOLITION PLAN - TECHNOLOGY - BLDG 1

1-TD-10G GROUND FLOOR DEMOLITION PLAN - TECHNOLOGY - BLDG 1

1-TD-10GA GROUND FLOOR DEMOLITION - TECHNOLOGY - AREA A - BLDG 1

1-TD-10GB GROUND FLOOR DEMOLITION - TECHNOLOGY - AREA B - BLDG 1

1-TD-10GC GROUND FLOOR DEMOLITION - TECHNOLOGY - AREA C - BLDG 1

1-TD-10GD GROUND FLOOR DEMOLITION - TECHNOLOGY - AREA D - BLDG 1

1-TD-101 FIRST FLOOR DEMOLITION PLAN - TECHNOLOGY - BLDG 1

1-TD-101A FIRST FLOOR DEMOLITION - TECHNOLOGY - AREA A - BLDG 1

1-TD-101B FIRST FLOOR DEMOLITION - TECHNOLOGY - AREA B - BLDG 1

1-TD-101C FIRST FLOOR DEMOLITION - TECHNOLOGY - AREA C - BLDG 1

1-TD-101D FIRST FLOOR DEMOLITION - TECHNOLOGY - AREA D - BLDG 1

1-TD-102 SECOND FLOOR DEMOLITION PLAN - TECHNOLOGY - BLDG 1

1-TD-102A SECOND FLOOR DEMOLITION - TECHNOLOGY - AREA A - BLDG 1

1-TD-102B SECOND FLOOR DEMOLITION - TECHNOLOGY - AREA B - BLDG 1

1-TD-102C SECOND FLOOR DEMOLITION - TECHNOLOGY - AREA C - BLDG 1

1-TD-102D SECOND FLOOR DEMOLITION - TECHNOLOGY - AREA D - BLDG 1

1-TD-103 THIRD FLOOR DEMOLITION PLAN - TECHNOLOGY - BLDG 1

1-TD-103A THIRD FLOOR DEMOLITION - TECHNOLOGY - AREA A - BLDG 1

1-TD-103B THIRD FLOOR DEMOLITION - TECHNOLOGY - AREA B - BLDG 1

1-TD-103C THIRD FLOOR DEMOLITION - TECHNOLOGY - AREA C - BLDG 1

1-TD-103D THIRD FLOOR DEMOLITION - TECHNOLOGY - AREA D - BLDG 1

1-TD-104 FOURTH FLOOR DEMOLITION PLAN - TECHNOLOGY - BLDG 1

1-TD-104A FOURTH FLOOR DEMOLITION - TECHNOLOGY - AREA A - BLDG 1

1-TD-104B FOURTH FLOOR DEMOLITION - TECHNOLOGY - AREA B - BLDG 1

1-TD-104C FOURTH FLOOR DEMOLITION - TECHNOLOGY - AREA C - BLDG 1

1-TD-104D FOURTH FLOOR DEMOLITION - TECHNOLOGY - AREA D - BLDG 1

1-TD-105 FIFTH FLOOR DEMOLITION PLAN - TECHNOLOGY - BLDG 1

1-TD-105B FIFTH FLOOR DEMOLITION - TECHNOLOGY - AREA B - BLDG 1

1-TD-105C FIFTH FLOOR DEMOLITION - TECHNOLOGY - AREA C - BLDG 1

1-TD-106 SIXTH FLOOR DEMOLITION PLAN - TECHNOLOGY - BLDG 1

1-TD-106C SIXTH FLOOR DEMOLITION - TECHNOLOGY - AREA C - BLDG 1

1-TD-107 SEVENTH FLOOR DEMOLITION PLAN - TECHNOLOGY - BLDG 1

1-TD-107C SEVENTH FLOOR DEMOLITION - TECHNOLOGY - AREA C - BLDG 1

3-T-100 BASEMENT FLOOR PLANS - TELECOMMUNICATIONS - BLDG 3

3-T-101 FIRST FLOOR PLANS - TELECOMMUNICATIONS - BLDG 3

3-T-200 TELECOMMUNICATIONS ROOM ENLARGEMENTS - BLDG 3

4-T-100 BASEMENT FLOOR PLANS - TECHNOLOGY - BLDG 4

4-T-101 FIRST FLOOR PLANS - TECHNOLOGY - BLDG 4

4-T-200 TECHNOLOGY ROOM ENLARGEMENTS - BLDG 4

5-T-100 BASEMENT FLOOR PLAN - TECHNOLOGY - BLDG 5

5-T-101 FIRST FLOOR PLAN - TECHNOLOGY - BLDG 5

5-T-200 TECHNOLOGY ROOM ENLARGEMENTS - BLDG 5

6-T-100 BASEMENT FLOOR PLAN - TECHNOLOGY - BLDG 6

6-T-101 FIRST FLOOR PLAN - TECHNOLOGY - BLDG 6

6-T-200 TECHNOLOGY ROOM ENLARGEMENTS - BLDG 6

7-T-100 BASEMENT FLOOR PLAN - TECHNOLOGY - BLDG 7

7-T-101 FIRST FLOOR PLAN - TECHNOLOGY - BLDG 7

7-T-200 TECHNOLOGY ROOM ENLARGEMENTS - BLDG 7

8-T-101 FIRST FLOOR PLAN - TECHNOLOGY - BLDG 8

8-T-200 TECHNOLOGY ROOM ENLARGEMENTS - BLDG 8

17-T-101 FIRST FLOOR PLAN - TECHNOLOGY - BLDG 17

19-T-101 FIRST FLOOR PLAN - TECHNOLOGY - BLDG 19

T-400 TECHNOLOGY DETAILS

T-401 TECHNOLOGY DETAILS

T-500 TECHNOLOGY DIAGRAMS

T-501 TECHNOLOGY DIAGRAMS

T-502 TECHNOLOGY DIAGRAMS

T-503 TECHNOLOGY DIAGRAMS

T-504 TECHNOLOGY DIAGRAMS

T-505 TECHNOLOGY DIAGRAMS

T-600 TECHNOLOGY SCHEDULES

TOTAL: 102

Revisions: Date:

1. THE EXISTING MAIN COMPUTER ROOM (MCR) AND TELECOM ROOMS (TR) TO REMAIN

OPERATIONAL DURING THE INSTALLATION OF THE NEW STRUCTURED CABLING AND

BACKBONE CABLING SYSTEMS. THE EXISTING SYSTEMS SHALL NOT BE DISRUPTED UNLESS

COORDINATED IN ADVANCE WITH OIT AND AT THEIR DISCRETION ON DATE AND TIME.

2. COORDINATE EACH TR CUTOVER WITH OIT AT THEIR DISCRETION ON DATE AND TIME.

PHASE 1 - PATHWAYS AND NEW INFRASTRUCTURE

1. INSTALL NEW INTER-BUILDING UNDERGROUND DUCT BANK CONDUITS.

2. BUILDOUT NEW TR LOCATIONS.

3. REMODEL EXISTING MCR

A. INSTALL DUST CONTAINTMENT PARTITION IN FRONT OF EXISTING CABINETS TO ALLOW

REMODEL OF “SIDE A” OF THE ROOM.

B. INSTALL “SIDE A” CABINETS, CABLE TRAY, AND CABLING.

C. INSTALL TEMPORARY FIBER OPTIC BACKBONE EXTENSION FOR TEMPORARY MIGRATION

OF “CORE B” SWITCH TO COMPLETED “SIDE A”.

D. COORDINATE MIGRATION OF EQUIPMENT AND CUTOVER TO NEW FIBER OPTIC

BACKBONES INTO NEW CABINETS WITH OIT

E. INSTALL “SIDE B” HALF OF MCR AFTER SUCCESSFUL “SIDE A” MIGRATION OF EQUIPMENT

F. COORDINATE MIGRATION OF EQUIPMENT AND CUTOVER TO NEW FIBER OPTIC

BACKBONES INTO NEW CABINETS WITH OIT

PHASE 2 - BACKBONE CABLING

1. INSTALL INTER-BUILDING BACKBONE CABLING.

2. INSTALL INTRA-BUILDING BACKBONE CABLING.

3. TERMINATE AND TEST.

PHASE 3 - HORIZONTAL CABLING

1. INSTALL NEW CAT 6A CABLING.

A. TERMINATE CABLING IN NEW TR PATCH PANELS.

B. NEATLY COIL CABLING AT EXISTING OR EXPANDED TR LOCATIONS FOR CUTOVER TO

NEW RACKS AND PATCH PANELS.

C. NEATLY COIL CABLING AT EXISTING OUTLET LOCATIONS.

PHASE 4 - CUTOVER

1. OIT INSTALLATION OF NETWORK SWITCHES AT EACH TR PLANNED FOR CUTOVER

2. REMOVE EXISTING OUTLET CABLING FROM OUTLET AND ROUTE NEW CAT 6A CABLING INTO

OUTLET.

A. NEATLY COIL EXISTING CABING ABOVE CEILING.

3. REMOVE EXISTING EQUIPMENT RACKS AND INSTALL NEW EQIUPMENT RACKS EQUIPMENT IN

REMODELED OR EXPANDED TR.

4. TERMINATE AND TEST NEW CABLING.

5. OIT CUTOVER AND PATCHING TO NETWORK SWITCHES.

PHASE 5 - DEMOLITION

1. REMOVE OLD FIBER OPTIC BACKBONE CABLING FROM EACH OLD TR FOLLOWING

SUCCESSFULL CUTOVER TO NEW TR.

A. OTHER EXISTING SYSTEMS IN OLD TR TO REMAIN FUNCTIONAL.

2. REMOVE OLD HORIZONTAL CABLING FROM EACH OUTLET BACK TO ITS SOURCE FOLLOWING

SUCCESSFUL CUTOVER.

3. REMOVE ALL EQUIPMENT RACKS AND ASSOCIATED EQUIPMENT FROM EACH OLD TR

FOLLOWING SUCCESSFUL CUTOVER.

TECHNOLOGY PHASING NOTES

1. SCOPE OF WORK INCLUDES RE-USE OF EXISTING TELECOMMUNICATIONS OUTLET ROUGH-

IN FOR NEW CATEGORY 6A CABLING. NEW CATEGORY 6A CABLING AT EXISTING OUTLET

LOCATIONS SHALL BE AS FOLLOWS:

• EXISTING 3/4” CONDUIT ROUGH-IN LOCATIONS TO RECEIVE A MAXIMUM OF TWO (2)

CAT 6A CABLES

• EXISTING 1” CONDUIT ROUGH-IN LOCATIONS TO RECEIVE A MAXIMUM OF FOUR (4)

CAT 6A CABLES

• PROVIDE NEW CONDUIT AND BACKBOX AT LOCATIONS EXCEEDING THE

REQUIREMENTS LISTED ABOVE. NEW CONDUIT SIZE SHALL BE BASED ON 40% FILL,

TAKING INTO CONSIDERATION THE DERATING OF THE CONDUIT CAPACITY FOR EACH

90 DEGREE BEND

2. NEW OUTLET LOCATIONS REQURING NEW IN-WALL OR SURFACE MOUNT ROUGH-IN ARE

NOTED ON THE DRAWINGS.

3. CONCEAL ALL NEW CONDUIT IN WALLS, PARTITIONS, ABOVE CEILING, IN FLOOR SLAB, ETC.

UNLESS OTHERWISE INDICATED ON THE PLANS OR IN THE SPECIFICATIONS. CONDUIT IN

MECHANICAL ROOMS AND STORAGE ROOMS WITHOUT CEILINGS MAY BE EXPOSED ON

BUILDING STRUCTURE.

4. BOXES LOCATED ON OPPOSITE SIDES OF NON-RATED WALLS SHALL BE OFFSET A MINIMUM

OF 6" HORIZONTALLY. BOXES ON OPPOSITE SIDES OF FIRE RATED WALLS SHALL BE

OFFSET A MINIMUM OF 24" HORIZONTALLY. "THRU-THE-WALL" BOXES SHALL NOT BE

ALLOWED WITHOUT PRIOR WRITTEN APPROVAL OF THE ARCHITECT/ENGINEER.

5. THE COMPLETE INSTALLATION SHALL BE IN ACCORDANCE WITH THE ADA STANDARDS FOR

ACCESSIBLE DESIGN. REFER TO THE ADA GUIDELINES FOR ALL CONFIGURATION DETAILS

ON THIS SHEET FOR ADDITIONAL INFORMATION.

6. TELECOMMUNICATIONS EQUIPMENT SHALL BE MOUNTED TO ALLOW ACCESS TO

ELECTRICAL AND MECHANICAL EQUIPMENT. ALL MOUNTING OF TELECOMMUNICATION

DEVICES ON EQUIPMENT SUPPLIED BY ANOTHER CONTRACTOR SHALL BE APPROVED IN

ADVANCE BY THE OTHER CONTRACTOR.

7. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL OPENINGS REQUIRED IN WALLS. ALL

OPENINGS SHALL BE REPAIRED TO MATCH EXISTING BY A QUALIFIED CONTRACTOR AT THE

EXPENSE OF THIS CONTRACTOR. ALL CONDUITS THROUGH WALLS SHALL BE GROUTED OR

SEALED INTO OPENINGS.

8. ALL MATERIALS USED TO SEAL PENETRATIONS OF FIRE RATED WALLS AND FLOORS SHALL

BE TESTED AND CERTIFIED AS A SYSTEM PER ASTM E814 STANDARDS FOR FIRE TESTS OF

THROUGH-PENETRATION FIRESTOPS. REFER TO DIVISON 7 FOR ADDITIONAL INFORMATION

AND REQUIREMENTS SPECIFIC TO FIRESTOPPING.

9. THE TECHNOLOGY CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND REPLACEMENT OF

THE CEILINGS, CEILING TILES, AND CEILING GRID ASSOCIATED WITH THE AREAS OF WORK

BY ALL CONTRACTORS. NOTIFY THE GENERAL CONTRACTOR OF AFFECTED AREAS PRIOR

TO BIDDING.

10. ALL CABLE TRAY SIZES ARE AS DEFINED ON THE DRAWINGS. REFER TO SPECIFICATIONS

FOR INSTALLATION REQUIREMENTS.

11. FLUSH MOUNT ALL TELECOMMUNICATION OUTLETS AT +18" FROM FLOOR (CENTERLINE

DIMENSION), EXCEPT WHERE OTHERWISE NOTED. OUTLETS MAY BE SURFACE MOUNTED

WHEN CONDUIT IS SPECIFIED EXPOSED.

12. EACH CONTRACTOR IS RESPONSIBLE FOR DAMAGE CAUSED BY THEIR ACTIONS TO THE

WALLS, FLOORS, CEILINGS, AND ROOFS. THE CONTRACTOR WHOSE WORK CAUSES

DAMAGE IS RESPONSIBLE FOR PATCHING TO MATCH ORIGINAL CONSTRUCTION, FIRE

RATING, AND FINISH.

TECHNOLOGY INSTALLATION NOTES:

1. THE LOCATION OF THE CONDUIT, HAND HOLES AND/OR MAINTENANCE HOLES SHOWN ARE

APPROXIMATE LOCATIONS. FIELD VERIFY THE LOCATION OF ALL UTILITIES PRIVATE AND/OR

PUBLIC PRIOR TO THE INSTALLATION OF THE COMPONENT. FIELD COORDINATE THE FINAL

LOCATION WITH THE OWNER AND ENGINEER PRIOR TO INSTALLATION.

2. POTHOLING TO LOCATE EXISTING UNDERGROUND UTILITIES, IF APPLICABLE, SHALL BE

INCLUDED IN THE CONTRACTOR'S BID. CONTRACTOR IS RESPONSIBLE FOR FINAL

PLACEMENT OF HAND HOLES AND/OR MAINTENANCE HOLES AND SHALL NOTIFY THE

ENGINEER OF FINAL LOCATIONS PRIOR TO INSTALLATION.

3. HAND HOLES AND/OR MAINTENANCE HOLES SHALL BE CONSTRUCTED SO THAT THE TOP OF

THE FRAME WILL BE FLUSH WITH THE GROUND LINE.

4. REMOVAL AND REPLACEMENT OF THE EXISTING UNDERGROUND UTILITIES THAT ARE

REQUIRED TO COMPLETE THE INSTALLATION SHALL BE INCLUDED IN THE CONTRACTOR'S

BID.

5. CONTRACTOR SHALL INCLUDE IN THEIR BID ANY REMOVAL AND REPLACEMENT OF EXISTING

SIDEWALK, PAVEMENT, GRASS, SHRUBS, TREES, ETC. THAT WILL BE IMPACTED BY THE

INSTALLATION OF THE NEW CONDUITS SHOWN ON THE DRAWINGS. IF TREES ARE REQUIRED

TO BE REMOVED THE CONTRACTOR SHALL CONTACT THE OWNER AND DISCUSS OPTIONS

PRIOR TO CUTTING DOWN ANY TREE OR SHRUB OVER 5' IN HEIGHT.

6. NO ADDITIONAL COST SHALL BE APPROVED FOR PLACING CONDUITS DEEPER THAN

REQUIRED MINIMUM DEPTH TO AVOID EXISTING UNDERGROUND UTILITIES.

7. PROVIDE A MINIMUM OF 25'-0" SLACK LOOP WITHIN EACH HAND HOLES AND/OR

MAINTENANCE HOLES. SLACK LOOP SHALL BE SECURE SO COPPER OR FIBER IS NOT

RESTING ON EARTH AFTER FINAL INSTALLATION.

TECHNOLOGY OUTSIDE PLANT NOTES

1. THE DRAWINGS INDICATE EXISTING ITEMS TO BE REMOVED. THE DRAWINGS ARE

INTENDED TO INDICATE THE SCOPE OF WORK REQUIRED AND DO NOT INDICATE EVERY

BOX, CONDUIT, OR WIRE THAT MUST BE REMOVED. THE CONTRACTOR SHALL VISIT THE

SITE PRIOR TO SUBMITTING A BID AND VERIFY EXISTING CONDITIONS.

2. ITEMS REMOVED REMAIN THE PROPERTY OF THE OWNER. THE CONTRACTOR SHALL BE

RESPONSIBLE FOR THE DISPOSAL OF MATERIAL THE OWNER DOES NOT WANT TO

REUSE OR RETAIN. (i.e., FOR MAINTENANCE PURPOSES).

3. EXISTING TO REMAIN DEVICES WITHIN OR ADJACENT TO THE PATH OF CONSTRUCTION

SHALL BE PROTECTED IN PLACE. DEVICES THAT MUST BE REMOVED SHALL BE TESTED

PRIOR TO REMOVAL, PROTECTED FROM DAMAGE, AND RE-INSTALLED IN ITS ORIGINAL

LOCATION DURING THE NEW CONSTRUCTION PHASE OF THE PROJECT.

4. OBTAIN APPROVAL FROM THE OWNER BEFORE TURNING OFF THE POWER TO

EQUIPMENT, SYSTEMS, PANELS, ETC. COORDINATE ALL OUTAGES WITH OWNER.

CONDUIT CONCEALED IN WALL CONSTRUCTION MAY BE ABANDONED IN PLACE IF NOT

AFFECTED BY OTHER CONSTRUCTION.

5. ALL CONDUIT SHALL BE REMOVED WHERE WALLS ARE BEING REMOVED. WHERE

CONDUIT IS IN THE CONCRETE SLAB, CUT OFF FLUSH, PULL OUT WIRE, AND PLUG.

WHERE CONDUIT IS RUN EXPOSED, ALL ASSOCIATED CLAMPS, SUPPORTS, HANGERS,

ETC., SHALL ALSO BE REMOVED.

6. COORDINATE ALL WORK WITH OTHER CONTRACTORS AT THE JOB SITE BEFORE

REMOVING EXISTING EQUIPMENT AND INSTALLING NEW ITEMS.

7. EXISTING CONDUIT IN GOOD CONDITION, MAY BE REUSED IN PLACE. RELOCATING

EXISTING CONDUIT SHALL NOT BE ALLOWED. BONDING CONDUCTORS SHALL BE

INSTALLED IN ALL REUSED CONDUIT TO ASSURE PROPER GROUND PATH.

8. EQUIPMENT REMOVAL IN CERTAIN LOCATIONS MAY REQUIRE THE INSTALLATION OF A

JUNCTION BOX TO RECONNECT CIRCUITS THAT REMAIN IN OPERATION. EXTEND

CONDUIT AND WIRING AS REQUIRED TO MAINTAIN POWER TO REMAINING EQUIPMENT.

9. DEVICES TO BE REMOVED SHALL HAVE ALL CONNECTED WIRING REMOVED TO THE

SOURCE.

10. DEVICES NOT TO BE REMOVED SHALL BE PROTECTED FROM THE ENVIRONMENT, AND

ALL ASSOCIATED CABLE/RACEWAYS ARE TO REMAIN AND BE PROTECTED. T.C. SHALL BE

RESPONSIBLE FOR REPAIR OF ANY INTERRUPTIONS TO PROTECTED DEVICES.

TECHNOLOGY DEMOLITION NOTESTECHNOLOGY GENERAL NOTES:

1. ###-### INDICATES TECHNOLOGY EQUIPMENT SCHEDULE ITEM LABELED AS "EQUIPMENT

LIST ABBREVIATION"

2. REFER TO TECHNOLOGY EQUIPMENT SCHEDULE AND SPECIFICATIONS FOR FULL

DESCRIPTIONS AND MANUFACTURERS OF ALL DEVICES.

TECHNOLOGY MOUNTING SUBSCRIPT KEY:

A MOUNT AT +6" TO CENTERLINE ABOVE COUNTER OR BACKSPLASH

H MOUNT ORIENTED HORIZONTALLY

L MOUNT IN CASEWORK

M MOUNT IN MODULAR FURNITURE

S MOUNT IN SURFACE RACEWAY

A SLASH IS USED BETWEEN TWO SUBSCRIPTS, E.G., A/H.

M

A X

20" MAX.

M

A X

20"-25" MAX.

M

A X

M

IN

. 4

M

A X

M

A X

10" MAX. 10"-24" MAX.

ADA GUIDELINES - FRONT ACCESS

ADA STANDARDS FOR ACCESSIBLE DESIGN

INSTALL ABOVE COUNTER

DEVICE AT 44" ABOVE

FINISHED FLOOR.

INSTALL ABOVE COUNTER

DEVICE AT 40" ABOVE

FINISHED FLOOR.

INSTALL DEVICE AT 18"

ABOVE FINISHED FLOOR.

ADA GUIDELINES - SIDE ACCESS

INSTALL DEVICE AT 44"

ABOVE FINISHED FLOOR.

INSTALL DEVICE AT 42"

ABOVE FINISHED FLOOR.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

636A-21-701

9/2/2022

EHRM INFRASTRUCTURE

UPGRADES

CONSTRUCTION

DOCUMENTS

GRAND ISLAND, NE

Alesia Architecture P.C.

3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941

Shaffer Stevens & Schaap P.C.

1070 Howard Street Omaha, NE 68102 Phone: (402) 455-7698

Specialized Engineering Solutions 10360 Ellison Circle Omaha, NE 68134 Phone: (402) 991-5520

IMEG Corp.

2882 106th Street Des Moines, IA 50322 Phone (515) 334-4324

Thompson, Dreessen & Dorner, Inc.

10836 Old Mill Rd Omaha, NE 68154 Phone: (402) 330-8860

AMI Environmental Inc 8802 S 135th Street Omaha, NE 68138 Phone: (402) 397-5001

B

IM

/2

-1 a -2

-7

V

A G ra n d I s la n d

E H

R M

/6

A

-7

.C a m p u s G e n e ra l_

T e c h

C

.r v t

/1

/2

:2

:0

P M

T-001

TECHNOLOGY NOTES

PND DJJRevisions: Date:

F.F .E.

.40

B U

IL

D

IN

G

N O R

TH

W H E E L E R

A V E N U E

BUILDING

2324 NORTH

WHEELER

AVENUE

G

AR

AG

E

B U

IL

D

IN

G

N O R

TH

B R O A D W E L L

A V E N U E

B U

IL

D

IN

G

N O R

TH

B R O A D W E

LL

A V E N U E

G

AR

AG

E

B U

IL

D

IN

G

B

LD

G

B U I L D I N G

B

U

I L D

I N

G

BUILDING

B

LD

G

B U

IL

D

IN

G

N O R

TH

W H E E

LE

R

AV

E N U E

W

IN

D O W

W E

LL

(T

YP

W

IN

D O W

W E

LL

W

IN

D O W

W E

LL

R R

R

R R

R R R

R R

R

R R

R

C P

C P

S

IG

N

P

LA

Y G R O U N D

E Q U

IP

M E N T

P

IC

N

IC

TA

B

LE

S

IG

N

S

IG

N

C O N C R E

TE

P

AD

C O N C R E

TE

S

ID

E W

AL

K

C O N C R E

TE

S

ID

E W

AL

K

C O N C R E

TE

S

ID

E W

AL

K

C O N C R E

TE

S

ID

E W

AL

K

C O N C R E

TE

C O N C

C O N C

C O N C R E

TE

C O N C R E

TE

CONCRETE

C O N C R E

TE

S

ID

E W

AL

K

C

ON

C

RE

TE

C O N C R E

TE

S

ID

E W

AL

K

C O N C R E

TE

S

ID

E W

AL

K

P

LA

N

TE

R

684.36' R

.1

R

6.1

5' R

.2

R

375.01' R

.7

R

.0

R

4.8

3' R

.7

R

217.91' R

.1

R

85.14' R

.0

R

V P

AC

K

AC

AC

PB

P B

P B

P B

F.

F.

E .7

F.

F.

E

.2

ACAC

F.

F.

E

.9

F.

F.

E

.8

F.

F.

E

.8

F.

F.

E

.9

F.

F.

E

.7

AC

AC

AC

ACACAC

F.

F.

E .8

F.

F.

E .8

F.

F.

E .2

AC

F.

F.

E

.1

F.

F.

E

.1

PB

AC

P

BF.

F.

E .3

P B

P B

F.

F.

E .2

AC

AC AC

F.

F.

E

.0

P B

P B

F.

F.

E

.9

F.

F.

E

.2

F.

F.

E

.2

F.

F.

E .9

F.

F.

E

.4

2D

ABANDON EXISTING CONDUITS

AFTER INSTALLATION OF NEW FIBER

OPTIC CABLING. REMOVE EXISTING

FIBER OPTIC AND COPPER CABLING

AFTER SUCCESSFUL CUTOVER.

EXISTING TUNNEL

ENTRANCE FROM

BUILDING 1 TO

BUILDING 7

EXISTING CONDUIT

PATHWAY "LEG A"

EXISTING

MAN HOLE

DROP OFF (4) 4" CONDUITS

FOR CABLING TO EXISTING

CONDUITS EXITING TUNNEL

(6) 4" CONDUITS

"LEG A"

(2) 4" CONDUITS

"LEG A"

(8) 4" CONDUITS

"LEG B"

(4) 4" CONDUITS

"LEG B"

(2) 4" CONDUITS

"LEG B"

(2) 4" CONDUITS

"LEG B"

(2) 4" CONDUITS

"LEG B"

PW-HH-1

PW-HH-1

PW-HH-1

PW-HH-1

PW-HH-1

PW-HH-1

EXISTING

HAND HOLE

EXISTING

HAND HOLE

EXISTING

HAND HOLE

EXISTING CONDUIT

PATHWAY "LEG A"

EXISTING CONDUIT

PATHWAY "LEG A"

EXISTING CONDUIT

PATHWAY "LEG A"

PW-HH-1 (4) 4" CONDUITS

"LEG A"

(4) 4" CONDUITS

"LEG A"

(6) 4" CONDUITS

"LEG B"

(2) 4" CONDUITS

"LEG B"

(4) 4" CONDUITS

"LEG B"

(2) 4" CONDUITS

"LEG B"

ROUTE CONDUITS FROM

TUNNEL ENTRY TO

BUILDING 7 TR

"LEG A" BACKBONE

PATHWAY TO

BUILDINGS 3, 4, & 5

"LEG B" BACKBONE

PATHWAY TO

BUILDINGS 3, 4, & 5

"LEG A" BACKBONE

PATHWAY TO

BUILDINGS 6, 7, 8, & 19

"LEG B" BACKBONE

PATHWAY TO

BUILDINGS 6, 7, 8, & 19

B U

IL

D

IN

G

B U

IL

D

IN

G

BUILDING 5

BUILDING 7

BUILDING 8

BUILDING 6

BUILDING 1

DATA FOR MOBILE MRI TRAILER

LOCATED IN EXISTING PEDESTAL

WITH EXISTING PATHWAY TO

BUILDING 17

(1) 4" CONDUIT

BUILDING

B U

IL

D

IN

G

BUILDING 18

TRUE

NORTH

PLAN

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

636A-21-701

9/2/2022

EHRM INFRASTRUCTURE

UPGRADES

CONSTRUCTION

DOCUMENTS

GRAND ISLAND, NE

Alesia Architecture P.C.

3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941

Shaffer Stevens & Schaap P.C.

1070 Howard Street Omaha, NE 68102 Phone: (402) 455-7698

Specialized Engineering Solutions 10360 Ellison Circle Omaha, NE 68134 Phone: (402) 991-5520

IMEG Corp.

2882 106th Street Des Moines, IA 50322 Phone (515) 334-4324

Thompson, Dreessen & Dorner, Inc.

10836 Old Mill Rd Omaha, NE 68154 Phone: (402) 330-8860

AMI Environmental Inc 8802 S 135th Street Omaha, NE 68138 Phone: (402) 397-5001

3 4

10 11

6 191

KEYPLAN

B

IM

/2

-1 a

-2

-7

V A

G ra n d I s la n d

E H

R M

/6

A

-7

.B

T e c h

C

.r v t

/1

/2

:3

:2

P M

T-002

SITE PLAN - TECHNOLOGY

PND DJJ

1" = 40'-0"

SITE PLAN - TECHNOLOGY

0 40' 80'20'

D

W

D

CRAWL

SPACE

CRAWL

SPACE

CRAWL

SPACE

CRAWL

SPACE

CRAWL

SPACE

41 2 5 6 7 8 9 10 11 13 14 15 16 17 18 20 21 22 23 24 25 26 27 28

A

B

C

D

E

F

G

H

J

K

L

M

N

P

R

S

T

U

V

W

X

Y

Z

AA

BB

CC

DD

EXISTING CABLE TRAY

EXISTING 4"

RISER CONDUITS

CABLE TRAY EXTENDS

THROUGH TUNNEL TO

BUILDING 7

TRUE

NORTH

PLAN

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

636A-21-701

9/2/2022

EHRM INFRASTRUCTURE

UPGRADES

CONSTRUCTION

DOCUMENTS

GRAND ISLAND, NE

Alesia Architecture P.C.

3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941

Shaffer Stevens & Schaap P.C.

1070 Howard Street Omaha, NE 68102 Phone: (402) 455-7698

Specialized Engineering Solutions 10360 Ellison Circle Omaha, NE 68134 Phone: (402) 991-5520

IMEG Corp.

2882 106th Street Des Moines, IA 50322 Phone (515) 334-4324

Thompson, Dreessen & Dorner, Inc.

10836 Old Mill Rd Omaha, NE 68154 Phone: (402) 330-8860

AMI Environmental Inc 8802 S 135th Street Omaha, NE 68138 Phone: (402) 397-5001

3 4

10 11

6 191

KEYPLAN

B

IM

/2

-1 a

-2

-7

V A

G ra n d I s la n d

E H

R M

/6

A

-7

.B

T e c h

C

.r v t

/1

/2

:2

:0

P M

1-T-10B

BASEMENT FLOOR PLAN - TECHNOLOGY -

BLDG 1

PND DJJ

1/16" = 1'-0"

BASEMENT FLOOR PLAN - TECHNOLOGY

KEYNOTES:

1. TUNNEL SHALL BE USED FOR "LEG A" FIBER

OPTIC BACKBONE PATHWAY AND COPPER

BACKBONE PATHWAY. REFER TO T-002 FOR

CONTINUATION.

0 16' 32'8'

SHEET NOTES:

1. ALL CABLING ON THIS SHEET SHALL BE

SERVED FROM TR-01-0.

TR

C5

MENS

TOILET

C7

WAREHOUSE

SUPPLY

RM

C8

BIO

MED

SHOP/OFFICE

C9

EEMS

STORAGE

C10

WAREHOUSE

STORAGE

C11

WAREHOUSE

STORAGE

C12

CANTEEN

STORAGE

C13

STORAGE

C14

STORAGE

C15

ER

SUPPLY

C16

C17

SUPPLY

WAREHOUSE

C18

PROSTHETICS

C17A

STORAGE

C20

STAIR

NO-6G

STORAGE

C17E

MECH

C17B

MECH

C17B

CHILLER

RM

G03

WAREHOUSE

STORAGE

C12A

WAREHOUSE

STORAGE

C11A

LOCKER

RM

N05

IT

OPERATORS

N08

N10

IT

SERVICES

N11

IT

OFFICE

N12

UNISEX

TOILET

N13 N14

WOMENS

LOCKER

N14A

IT

STORAGE

N15A

STORAGE

C22

CRAWL

SPACE

NO.7

CRAWL

SPACE

NO.6

CRAWL

SPACE

NO.8

CRAWL

SPACE

NO.9

S10

MAIL

RM

S9

MAIL

RM

OFFICE

S8

ARMORY

C23

POLICE

OFFICE

S4

FITNESS

CENTER

S6

STAIR

NO 4

SE2SE1

SPS

DISPATCH

S1 OFFICE

C24

OFFICE

S2 S3

IT

C25

SPS

LOCKER

RM

C28

EQUIP

RM

NE3A

EQUIR

RM

NE3B

NE2

MENS

TOILET

C29

WOMENS

TOILET

C30

RESTROOM

C31

SOILED

LINEN

CHUTE

N04

PAHTOLOGY

N06LOCKER

N17

STORAGE

N18

SOILED

LINEN

S7

CORR

NGCOR.1

CORR

NGCOR.2

CORR

SGCOR.1

CORR

SEGCOR.1

C O

R R

C G

C O

R .6

C O

R R

C G

C O

R .7

41 2 5 6 7 8 9 10 11 13 14 15 16 17 18 20 21 22 23 24 25 26 27 28

A

B

C

D

E

F

G

H

J

K

L

M

N

P

R

S

T

U

V

W

X

Y

Z

AA

BB

CC

DD

TR

1-C6

UPS

1-N02 MCR

1-C01

CANTEEN

OFFICE

1-NE0

OFFICE

1-NE1

CORR

1-CGCOR.1

CORR

1-NEGCOR.1

C O

R R

1- N

E G

C O

R .2

LAUNDRY

1-NE3

OFFICE

1-N07

ENTRANCE

ROOM

1-N09A

C O

R R

1- C

G C

O R

.2

C O

R R

1- C

G C

O R

.3

CORR

1-CGCOR.4

C O

R R

1- C

G C

O R

.5

CORR

1-NEGCOR.3

1-T-10G-TR-A

1-T-10G-TR-B

TR-01-0

1-T-10G-TR-B

ER-01

1-T-10G-TR-B

1-T-10G-TR-A

MCR-01

REFER TO T-002

FOR CONTINUATION

REFER TO T-002 FOR

CONTINUATION

REFER TO T-002 FOR

CONTINUATION

EXISTING

SECURITY

PANELS

6 6

1-T-10G-TR-B

TRUE

NORTH

PLAN

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

636A-21-701

9/2/2022

EHRM INFRASTRUCTURE

UPGRADES

CONSTRUCTION

DOCUMENTS

GRAND ISLAND, NE

Alesia Architecture P.C.

3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941

Shaffer Stevens & Schaap P.C.

1070 Howard Street Omaha, NE 68102 Phone: (402) 455-7698

Specialized Engineering Solutions 10360 Ellison Circle Omaha, NE 68134 Phone: (402) 991-5520

IMEG Corp.

2882 106th Street Des Moines, IA 50322 Phone (515) 334-4324

Thompson, Dreessen & Dorner, Inc.

10836 Old Mill Rd Omaha, NE 68154 Phone: (402) 330-8860

AMI Environmental Inc 8802 S 135th Street Omaha, NE 68138 Phone: (402) 397-5001

3 4

10 11

6 191

KEYPLAN

B

IM

/2

-1 a

-2

-7

V A

G ra n d I s la n d

E H

R M

/6

A

-7

.B

T e c h

C

.r v t

/1

/2

:2

:1

P M

1-T-10G

GROUND FLOOR PLAN - TECHNOLOGY -

BLDG 1

PND DJJ

1/16" = 1'-0"

GROUND FLOOR PLAN - TECHNOLOGY

KEYNOTES:

1. "LEG A" BACKBONE CABLING PATHWAY.

2. "LEG B" BACKBONE CABLING PATHWAY.

3. (6) EXISTING CONDUITS DOWN TO BASEMENT

LEVEL FOR "LEG A" PATHWAY TO OUT

BUILDINGS. REFER TO 1-T10B AND T-002 FOR

ADDITIONAL INFORMATION.

4. (4) EXISTING CONDUITS UP TO FIRST FLOOR

FOR "LEG A" PATHWAY TO BUILDING 1 TR.

5. PROVIDE (1) 4" CONDUIT SLEEVE UP TO FIRST

FLOOR.

6. (3) 4" CONDUIT SLEEVES. STUB CONDUITS AT

EXISTING CABLE TRAY ON EXTERIOR SIDE OF

TR. PROVIDE CORRUGATED INNERDUCT FOR

FIBER OPTIC CABLING.

0 16' 32'8'

SHEET NOTES:

1. ALL NEW CABLING SHALL BE INSTALLED IN

EXISTING CABLE TRAY LOCATED

THROUGHOUT THE CORRIDORS OF THE

FLOOR PLAN. PROVIDE J-HOOK PATHWAYS

FOR CABLING FROM EXISTING CABLE TRAY TO

OUTLET LOCATIONS.

1D 24" SPACE RESERVED

FOR IN-ROW COOLING

UNITS (TYP.)

1-T-10G-TR-A

4SC-CAB-1SC-CAB-1SC-CAB-1SC-CAB-2SC-CAB-2

SC-CAB-1SC-CAB-1SC-CAB-1 SC-CAB-1SC-CAB-1SC-CAB-1

SC-CAB-2SC-CAB-2

KEYNOTES:

1. "A SIDE"

A. INSTALL CABINETS, CABLING, AND CABLE TRAY ON THIS SIDE OF THE LINE.

B. COORDINATE MIGRATION OF EQUIPMENT WITH OIT TO NEW CABINETS.

C. PROVIDE TEMPORARY FIBER OPTIC PATCH CORD CONNECTIONS FROM

EXISTING CORE SWITCHES TO MIGRATED EQUIPMENT TO MAINTAIN

REDUNDANCY.

D. COORDINATE WITH OIT FOR TEMPORARY MIGRATION OF "CORE B" SWITCH TO

"A SIDE". REFER TO 1/T-10G-TR-A FOR ADDTIONAL INFORMATION.

2. "B SIDE"

A. INSTALL REMAINING CABINETS, CABLING, AND CABLE TRAY ON THIS SIDE OF

THE LINE.

B. COORDINATE MIGRATION OF "CORE B" SWITCH FROM TEMPORARY "A SIDE"

LOCATION TO PERMANENT "B SIDE" LOCATION.

C. COORDINATE MIGRATION OF EQUIPMENT WITH OIT TO NEW CABINETS.

SC-VPP-1

SC-GND-1

MDA "A"HDA "A"HDA "B"MDA "B"

SC-TTB

DATA FOR DDC.

COORDINATE LOCATION WITH

M.C. PRIOR TO INSTALLATION.

18"x4"

"x

"x

SC-CT-2 +110" AFF

(TYP.)

24" SPACE RESERVED FOR

IN-ROW COOLING UNITS

(TYP.)

SC-CAB-2 SC-CAB-2 SC-CAB-2 SC-CAB-2SC-CAB-1 SC-CAB-1 SC-CAB-1 SC-CAB-1 SC-CAB-1 SC-CAB-1 SC-CAB-1 SC-CAB-1 SC-CAB-1

SC-BLK-1

SC-FDC-1

SC-BLK-1

SC-VPP-2

SC-BLK-1

SC-VPP-2

SC-BLK-1

SC-VPP-2

SC-FDC-1

SC-FDC-1

SC-FDC-1

SC-MPP-2

SC-MPP-2

SC-MPP-2

SC-MPP-2

SC-MPP-2

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-FDC-1

SC-BLK-1

SC-MPP-2

SC-BLK-1

SC-FDC-1

SC-BLK-1

SC-MPP-2

SC-BLK-1

SC-FDC-1

SC-BLK-1

SC-MPP-2

SC-BLK-1

SC-FDC-1

SC-BLK-1

SC-MPP-2

SC-BLK-1

SC-FDC-1

SC-BLK-1

SC-MPP-2

SC-BLK-1

SC-FDC-1

SC-BLK-1

SC-MPP-2

SC-BLK-1

SC-FDC-1

SC-BLK-1

SC-MPP-2

SC-BLK-1

SC-FDC-1

SC-BLK-1

SC-MPP-2

SC-BLK-1

SC-BLK-1

SC-FDC-1

SC-MPP-2

SC-BLK-1

SC-FDC-1

SC-BLK-1

SC-FDC-1

SC-BLK-1

SC-FDC-1

SC-BLK-1

SC-MPP-2

SC-BLK-1

SC-MPP-2

SC-BLK-1

SC-MPP-2

SC-BLK-1

SC-MPP-2

SC-BLK-1

SC-MPP-2

SC-BLK-1

KEYNOTES:

1. INSTALL (1) SC-GND-2 AT TOP RU ON REAR MOUNTING RAILS OF EACH CABINET.

2. INSTALL (2) SC-PDU-3 AT THE REAR OF EACH CABINET.

SC-FDC-1

MDA "LEG A" HDA "LEG A" HDA "LEG B" MDA "LEG B"

SC-FDC-1

SC-MPP-2

SC-MPP-2

SC-MPP-2

SC-VPP-2

SC-VPP-2

SC-VPP-2

SC-VPP-2

SC-VPP-2

1 2 1 2

SC-FDC-1

1 2 1 2 1 2 1 2 2 2 1 2 1 2 1 2 1 2 1 211

EXISTING CABINET

(TYP.)

EXISTING 2-POST RACK

EXISTING FIBER OPTIC CABLING

EXISTING CORE SWITCH

REMOVE PULL BOX

NOTES:

1. COORDINATE WITH OIT FOR RELOCATION OF EXISTING EQUIPMENT TO NEW MCR-01

CABINETS AND CUTOVER TO NEW BACKBONE CABLING. EXISTING CABINETS AND

CABLING SHALL NOT BE REMOVED PRIOR TO CONFIRMATION FROM OIT.

2. EXISTING FIBER OPTIC CABLING SHALL REMAIN OPERATIONAL UNTIL SUCCESSFUL

CUTOVER TO NEW LEG "A" FIBER OPTIC BACKBONE. PROVIDE TEMPORARY

CONNECTIONS TO EXISTING FIBER OPTIC CABLING AS NECESSARY TO PERFORM

SUCCESSFUL "LEG A" CUTOVER TO REMODELED SIDE OF MCR-01.

3. FOR TEMPORARY MIGRATION OF EXISTING "CORE B" SWITCH

A. PULL "CORE B" EXISTING FIBER OPTIC BACKBONE BACK TO CORRIDOR AND

PROVIDE TEMPORARY ABOVE CEILING ENCLOSURE. PROVIDE TEMPORARY

FIBER OPTIC BACKBONE EXTENSION TO NEW "HDA A" CABINET FOR OIT

RELOCATION OF "CORE B" SWITCH.

B. FOR BIDDING PURPOSES ASSUME 24 STRANDS OS1 FIBER OPTIC CABLING FOR

TEMPORARY BACKBONE. CONFIRM FIBER TYPE AND STRAND COUNT NEEDS

WITH OIT PRIOR TO INSTALLATION.

PROVIDE PARTITION TO PROTECT EXISTING

EQUIPMENT FROM DUST AND DAMAGE

DURING REMOVAL OF CEILING AND RAISED

FLOOR ON THIS SIDE OF THE LINE

TEMPORARY "CORE B" FIBER OPTIC

ENCLOSURE ABOVE CEILING. SEE NOTES.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

636A-21-701

9/2/2022

EHRM INFRASTRUCTURE

UPGRADES

CONSTRUCTION

DOCUMENTS

GRAND ISLAND, NE

Alesia Architecture P.C.

3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941

Shaffer Stevens & Schaap P.C.

1070 Howard Street Omaha, NE 68102 Phone: (402) 455-7698

Specialized Engineering Solutions 10360 Ellison Circle Omaha, NE 68134 Phone: (402) 991-5520

IMEG Corp.

2882 106th Street Des Moines, IA 50322 Phone (515) 334-4324

Thompson, Dreessen & Dorner, Inc.

10836 Old Mill Rd Omaha, NE 68154 Phone: (402) 330-8860

AMI Environmental Inc 8802 S 135th Street Omaha, NE 68138 Phone: (402) 397-5001

B

IM

/2

-1 a

-2

-7

V A

G ra n d I s la n d

E H

R M

/6

A

-7

.B

T e c h

C

.r v t

/1

/2

:2

:1

P M

1-T-10G-TR-A

GROUND FLOOR PLAN - TECHNOLOGY -

ENLARGEMENTS - BLDG 1

PND DJJ

1/4" = 1'-0"

SERVER ROOM LAYOUT - MCR-01

2 1/4" = 1'-0"

SERVER ROOM PATHWAY - MCR-01

1" = 1'-0"

EQUIPMENT RACK ELEVATION - MCR-01

1/4" = 1'-0"

EXISTING ROOM LAYOUT - MCR-01

0 4' 8'2' 0 4' 8'2' 0 4' 8'2'

N N N

CCTV

1D

ENTRANCE

ROOM

1-N09A

SC-VPP-1

KEYNOTES:

1. EXISTING 110-BLOCK FRAME WITH HORIZONTAL MOUNTING RAILS. REMOVE

EXISTING MULTI-PAIR CABLING WHEN CUTOVER TO NEW TR BACKBONE

ARCHITECTURE IS COMPLETE.

2. 100-PAIR BACKBONE TO MCR-01. REFER TO T-500 FOR ADDITIONAL INFORMATION.

ENTRANCE ROOM

N09A

-T

-1 G

-T R

-B

SC-VWM-1

SC-ER-1

(TYP.)

(TYP.)

SC-GND-1

DATA FOR DDC.

COORDINATE LOCATION WITH

M.C. PRIOR TO INSTALLATION.

1-T-10G-TR-B

SC-VWM-1

SC-ER-1

SC-TTB

SC-GND-1

(TYP.)

(TYP.)

(TYP.)

NOTES:

1. REFER TO 3/1-T10G-TR-B FOR TELECOM ROOM PATHWAY -TR-01-0.

2. REFER TO T-600 FOR TECHNOLOGY EQUIPMENT SCHEUDLE.

3. REFER TO 1-S-501 FOR COORDINATION WITH STRUCTURAL SUPPORTS FOR TR RACK

INSTALLATION.

DATA FOR DDC.

COORDINATE LOCATION WITH

M.C. PRIOR TO INSTALLATION.

18"x4"

12"x4"

12"x4"

"x

"x

SC-CT-2

SC-CT-1

(TYP.)

NOTES:

1. INSTALL CABLE TRAY AT 7'-6" AFF.

2. REFER TO T-600 FOR TECHNOLOGY EQUIPMENT SCHEUDLE.

SC-ER-1 SC-VWM-1

(TYP.) (TYP.)

SC-UPS-1 SC-UPS-1SC-UPS-1

SC-BLK-1 SC-BLK-1 SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-FDC-1

SC-BLK-1

SC-MPP-1

SC-MPP-1

SC-MPP-1

SC-MPP-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1 SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-HWM-1

SC-HWM-2

SC-HWM-1

SC-HWM-2

SC-HWM-1

SC-HWM-2

SC-HWM-2

SC-HWM-2

SC-HWM-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

OWNER SWITCH

OWNER SWITCH

OWNER SWITCH

OWNER SWITCH

SC-HWM-2 SC-HWM-2

SC-HWM-1 SC-HWM-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

SC-BLK-1

KEYNOTES:

1. INSTALL SC-GND-2 AT TOP RU IN BACK OF EACH RACK.

2. INSTALL (2) SC-PDU-1 IN BACK OF EACH RACK.

SC-BLK-1

SC-BLK-1

(TYP.)

(TYP.)

SC-BLK-1

SC-BLK-1

SC-BLK-1 SC-BLK-1

SC-BLK-1

SC-BLK-1

KEYNOTES:

1. INSTALL SC-GND-2 AT TOP RU IN BACK OF EACH RACK.

2. INSTALL (2) SC-PDU-1 IN BACK OF EACH RACK.

SC-VWM-1SC-ER-1

(TYP.) (TYP.)

SC-BLK-1

SC-FDC-1

SC-BLK-1

SC-BLK-1

SC-FDC-1

SC-BLK-1

SC-UPS-1 SC-UPS-1

(TYP.)

(TYP.)

ENTRANCE

ROOM

1-N09A

NOTES:

1. INSTALL CABLE TRAY AT 7'-6" AFF.

2. REFER TO T-600 FOR TECHNOLOGY EQUIPMENT SCHEUDLE.

ENTRANCE ROOM

N09A

"x

"x

"x

12"x4"

12"x4"

CONNECT TO EXISTING

CABLE TRAY

SC-CT-1

(TYP.)

SC-CT-2

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

636A-21-701

9/2/2022

EHRM INFRASTRUCTURE

UPGRADES

CONSTRUCTION

DOCUMENTS

GRAND ISLAND, NE

Alesia Architecture P.C.

3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941

Shaffer Stevens & Schaap P.C.

1070 Howard Street Omaha, NE 68102 Phone: (402) 455-7698

Specialized Engineering Solutions 10360 Ellison Circle Omaha, NE 68134 Phone: (402) 991-5520

IMEG Corp.

2882 106th Street Des Moines, IA 50322 Phone (515) 334-4324

Thompson, Dreessen & Dorner, Inc.

10836 Old Mill Rd Omaha, NE 68154 Phone: (402) 330-8860

AMI Environmental Inc 8802 S 135th Street Omaha, NE 68138 Phone: (402) 397-5001

B

IM

/2

-1 a

-2

-7

V A

G ra n d I s la n d

E H

R M

/6

A

-7

.B

T e c h

C

.r v t

/1

/2

:2

:1

P M

1-T-10G-TR-B

GROUND FLOOR PLAN - TECHNOLOGY -

ENLARGEMENTS - BLDG 1

PND DJJ

1/4" = 1'-0"

ENTRANCE ROOM LAYOUT - ER-01

1/4" = 1'-0"

TELECOM ROOM LAYOUT - TR-01-0

4 1/4" = 1'-0"

TELECOM ROOM PATHWAY - TR-01-0

5 1" = 1'-0"

EQUIPMENT RACK ELEVATION - TR-01-0

0 4' 8'2'

0 4' 8'2' 0 4' 8'2'

N N N

1" = 1'-0"

EQUIPMENT RACK ELEVATION - ER-01

31/4" = 1'-0"

ENTRANCE ROOM PATHWAY - ER-01

N

2D

1D-WAP

W

1D-WAP

1D-WAP

MENS

TOILET

C7

WAREHOUSE

SUPPLY

RM

C8

EEMS

STORAGE

C10

EQUIP

RM

NE3A

EQUIR

RM

NE3B

NE2

MENS

TOILET

C29

WOMENS

TOILET

C30

RESTROOM

C31

41 2 5 6 7 8 9 10 11 13

P

R

S

T

U

V

W

X

Y

Z

AA

BB

CC

DD

TR

1-C6

C O

R R

1- N

E G

C O

R .2

LAUNDRY

1-NE3

TRUE

NORTH

PLAN

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

636A-21-701

9/2/2022

EHRM INFRASTRUCTURE

UPGRADES

CONSTRUCTION

DOCUMENTS

GRAND ISLAND, NE

Alesia Architecture P.C.

3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941

Shaffer Stevens & Schaap P.C.

1070 Howard Street Omaha, NE 68102 Phone: (402) 455-7698

Specialized Engineering Solutions 10360 Ellison Circle Omaha, NE 68134 Phone: (402) 991-5520

IMEG Corp.

2882 106th Street Des Moines, IA 50322 Phone (515) 334-4324

Thompson, Dreessen & Dorner, Inc.

10836 Old Mill Rd Omaha, NE 68154 Phone: (402) 330-8860

AMI Environmental Inc 8802 S 135th Street Omaha, NE 68138 Phone: (402) 397-5001

3 4

10 11

6 191

KEYPLAN

B

IM

/2

-1 a

-2

-7

V A

G ra n d I s la n d

E H

R M

/6

A

-7

.B

T e c h

C

.r v t

/1

/2

:2

:2

P M

1-T-100A

GROUND FLOOR - TECHNOLOGY - AREA A -

BLDG 1

PND DJJ

1/8" = 1'-0"

GROUND FLOOR - TECHNOLOGY - AREA A

1 0 8' 16'4'

1D

D

D

D

2D

1D-WAP

1D-WAP

D

W

1D-WAP

1D-WAP

D

1D-WAP

W

1D-WAP

D

D

1D-WAP

1D-WAP

W

1D

D

D

D

D

D

D

2D

2D

C

C T V

D

D

CSS

M

TR

C5

MENS

TOILET

C7

LOCKER

RM

N05

IT

OPERATORS

N08

N10

IT

SERVICES

N11 IT

OFFICE

N12

UNISEX

TOILET

N13 N14

WOMENS

LOCKER

N14A

IT

STORAGE

N15A

STORAGE

C22

CRAWL

SPACE

NO.7

SOILED

LINEN

CHUTE

N04

PAHTOLOGY

N06

LOCKER

N17

STORAGE

N18

CORR

NGCOR.1

CORR

NGCOR.2

41 2 5 6 7 8 9 10 11 13

A

B

C

D

E

F

G

H

J

K

L

M

N

P

TR

1-C6

UPS

1-N02

CANTEEN

OFFICE

1-NE0

OFFICE

1-NE1

CORR

1-NEGCOR.1

C O

R R

1- N

E G

C O

R .2

LAUNDRY

1-NE3

OFFICE

1-N07

ENTRANCE

ROOM

1-N09A

C O

R R

1- C

G C

O R

.2

CORR

1-NEGCOR.3

1-T-10G-TR-B

ER-01

INTRUSION DETECTION

PANEL

2 1

1 1

INSTALL NVR, MONITOR, AND

WALL MOUNT SHELF RELOCATED

FROM PREVIOUS CANTEEN OFFICE.

REFER TO 1-TD10GC FOR PREVIOUS

LOCATION.

TRUE

NORTH

PLAN

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

636A-21-701

9/2/2022

EHRM INFRASTRUCTURE

UPGRADES

CONSTRUCTION

DOCUMENTS

GRAND ISLAND, NE

Alesia Architecture P.C.

3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941

Shaffer Stevens & Schaap P.C.

1070 Howard Street Omaha, NE 68102 Phone: (402) 455-7698

Specialized Engineering Solutions 10360 Ellison Circle Omaha, NE 68134 Phone: (402) 991-5520

IMEG Corp.

2882 106th Street Des Moines, IA 50322 Phone (515) 334-4324

Thompson, Dreessen & Dorner, Inc.

10836 Old Mill Rd Omaha, NE 68154 Phone: (402) 330-8860

AMI Environmental Inc 8802 S 135th Street Omaha, NE 68138 Phone: (402) 397-5001

3 4

10 11

6 191

KEYPLAN

B

IM

/2

-1 a

-2

-7

V A

G ra n d I s la n d

E H

R M

/6

A

-7

.B

T e c h

C

.r v t

/1

/2

:2

:2

P M

1-T-100B

GROUND FLOOR - TECHNOLOGY - AREA B -

BLDG 1

PND DJJ

1/8" = 1'-0"

GROUND FLOOR - TECHNOLOGY - AREA B

KEYNOTES:

1. PROVIDE SURFACE MOUNT RACEWAY AND

BACKBOX FOR NEW OUTLET LOCATION. REFER

TO 2/T-401 FOR ADDITIONAL INFORMATION.

2. DATA FOR ELECTRONIC KEY BOX. PROVIDE (1)

1" CONDUIT FROM KEY BOX TO ABOVE

ACCESSIBLE CEILING.

0 8' 16'4'

D

D

1D-WAP

D

W

2D

2D

1D-WAP

D

D

W

2D2D2D

2D 2D

1D-WAP

2D W

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

D

W 2D 2D 2D

1D

W

W

1D-WAP

W

W

W

1D

W

C S

S

1D

TR

C5

MENS

TOILET

C7

SUPPLY

WAREHOUSE

C18

STORAGE

C20

STAIR

NO-6G

STORAGE

C17E

MECH

C17B

MECH

C17B

N14

CRAWL

SPACE

NO.6

CRAWL

SPACE

NO.8

S10

MAIL

RM

S9

MAIL

RM

OFFICE

S8

ARMORY

C23

POLICE

OFFICE

S4

FITNESS

CENTER

S6

STAIR

NO 4

SE2

SE1

SPS

DISPATCH

S1

OFFICE

C24 OFFICE

S2 S3

IT

C25

SPS

LOCKER

RM

C28

SOILED

LINEN

S7

CORR

SGCOR.1

CORR

SEGCOR.1

13 14 15 16 17 18 20 21 22 23 24 25 26 27 28

A

B

C

D

E

F

G

H

J

K

L

M

N

P

TR

1-C6

UPS

1-N02

MCR

1-C01

CORR

1-CGCOR.1

C O

R R

1- C

G C

O R

.2

C O

R R

1- C

G C

O R

.3

CORR

1-CGCOR.4

C O

R R

1- C

G C

O R

.5

1-T-10G-TR-B

TR-01-0

1-T-10G-TR-A

MCR-01

INTRUSION

DETECTION

PANEL

DATA FOR EXISTING

SECURITY PANEL

TRUE

NORTH

PLAN

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

636A-21-701

9/2/2022

EHRM INFRASTRUCTURE

UPGRADES

CONSTRUCTION

DOCUMENTS

GRAND ISLAND, NE

Alesia Architecture P.C.

3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941

Shaffer Stevens & Schaap P.C.

1070 Howard Street Omaha, NE 68102 Phone: (402) 455-7698

Specialized Engineering Solutions 10360 Ellison Circle Omaha, NE 68134 Phone: (402) 991-5520

IMEG Corp.

2882 106th Street Des Moines, IA 50322 Phone (515) 334-4324

Thompson, Dreessen & Dorner, Inc.

10836 Old Mill Rd Omaha, NE 68154 Phone: (402) 330-8860

AMI Environmental Inc 8802 S 135th Street Omaha, NE 68138 Phone: (402) 397-5001

3 4

10 11

6 191

KEYPLAN

B

IM

/2

-1 a

-2

-7

V A

G ra n d I s la n d

E H

R M

/6

A

-7

.B

T e c h

C

.r v t

/1

/2

:2

:2

P M

1-T-100C

GROUND FLOOR - TECHNOLOGY - AREA C -

BLDG 1

PND DJJ

1/8" = 1'-0"

GROUND FLOOR - TECHNOLOGY - AREA C

D

D

1D-WAP

1D-WAP

D

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-WAP

1D-CAM

W W2

D

D

2D

D

D

W

W

D

1D-WAP

3D

D

W

W

V

2D

MENS

TOILET

C7

WAREHOUSE

SUPPLY

RM

C8

BIO

MED

SHOP/OFFICE

C9

EEMS

STORAGE

C10

WAREHOUSE

STORAGE

C11

WAREHOUSE

STORAGE

C12

CANTEEN

STORAGE

C13

STORAGE

C14

STORAGE

C15

ER

SUPPLY

C16

C17

SUPPLY

WAREHOUSE

C18

PROSTHETICS

C17A

STORAGE

C20

STORAGE

C17E

MECH

C17B

MECH

C17B

CHILLER

RM

G03

WAREHOUSE

STORAGE

C12A

WAREHOUSE

STORAGE

C11A

CRAWL

SPACE

NO.9

SE2

SE1

C O

R R

C G

C O

R .6

C O

R R

C G

C O

R .7

13 14 15 16 17 18 20 21 22 23 24 25 26 27 28

P

R

S

T

U

V

W

X

Y

Z

AA

BB

CC

DD

TR

1-C6

C O

R R

1- C

G C

O R

.5

INTRUSION DETECTION

PANEL

TRUE

NORTH

PLAN

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

636A-21-701

9/2/2022

EHRM INFRASTRUCTURE

UPGRADES

CONSTRUCTION

DOCUMENTS

GRAND ISLAND, NE

Alesia Architecture P.C.

3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941

Shaffer Stevens & Schaap P.C.

1070 Howard Street Omaha, NE 68102 Phone: (402) 455-7698

Specialized Engineering Solutions 10360 Ellison Circle Omaha, NE 68134 Phone: (402) 991-5520

IMEG Corp.

2882 106th Street Des Moines, IA 50322 Phone (515) 334-4324

Thompson, Dreessen & Dorner, Inc.

10836 Old Mill Rd Omaha, NE 68154 Phone: (402) 330-8860

AMI Environmental Inc 8802 S 135th Street Omaha, NE 68138 Phone: (402) 397-5001

3 4

10 11

6 191

KEYPLAN

B

IM

/2

-1 a

-2

-7

V A

G ra n d I s la n d

E H

R M

/6

A

-7

.B

T e c h

C

.r v t

/1

/2

:2

:2

P M

1-T-100D

GROUND FLOOR - TECHNOLOGY - AREA D -

BLDG 1

PND DJJ

1/8" = 1'-0"

GROUND FLOOR - TECHNOLOGY - AREA D

SUPPLY

NE104

SOILED

NE105

OFFICE

NE106

OFFICE

NE107

HAC

NE108

LAB

NE109

CANTEEN

N102

OFFICE

N103

FEMALE

TOILET

N104

MALE

TOILET

N105

OFFICE

N106

PATIENT

EDUCATION

N107

WAITING

N112

STAIR

NO-3

CLINICAL

PHARMACIST

NW101

EXAM

RM

NW102

EXAM

RM

NW103

EXAM

RM

NW104

STORAGE

NW105

EXAM

RM

NW106

EXAM

RM

NW107

EXAM

RM

NW108

CLEAN

UTILITY

NW109

SOILED

UTILITY

NW110

EXAM

RM

NW111

CLEAN

LINEN

NW112

EXAM

RM

NW113

NURSE

STATION

NW114

EXAM

RM

NW115

EXAM

RM

NW116

CLINICAL

PHARMACIST

NW117

STAIR

NO-1

TOILET

NW107A

TOILET

NW108A

TOILET

NW111A

TR

C100

C101

OFFFICE

C101E

CONFERENCE

RM

C101D

FOOD

STORAGE

C115

VEG

RM

C101E

FREEZER

C102A

FREEZER

C102

C102B

FREEZER

C103

FREEZER

C113A

WOMENS

TOILET

C104

LINEN

CLOSET

C105

STORAGE

C106 FREEZER

C112

MALE

TOILET

C107

STORAGE

C111

WASH

RM/HAC

C110

HAC

C109

C108

STAIR-6

C34

INPATIENT

PHARMACY

SE102

IV

DISPENSING

SE103

SE104

CONFERENCE

RM

SE106

CHIEF

PHARMACY

SE107

VACANT

SE108

OFFICE

SE109

REST

RM

SE110

REST

RM

SE111

CONTROL

SUBSTANCE

SE112

PRESCRIPTIONS

SE115

PATIENT

RECIEVING

SE116

VACANT

SE117

MD

EXAM

SE118

EXAM

RM

SE119

MD

EXAM

SE120

EXAM

RM

SE121

SE122

EXAM

RM

SE124

MD

EXAM

SE125

MD

EXAM

SE126

EXAM

RM

SE127

NURSE

SE128

CLEAN

UTILITY

SE130

SOILED

UTILITY

SE131

ELIGIBILTY

SE133

NUTRITION

CLINIC

SE134

EXAM

RM

SE135

OFFICE

SE136

OFFICE

SE137

ELECTRICAL

SE138

TOILET

SE139

EXAM

RM

SE140

OFFICE

SE141

EXAM

RM

SE142

MD

EXAM

SE143

TELEHEALTH

SE144

TELEMEDICINE

SE145

SOCIAL

WORK

SE147

OFFICE

SE148

STAIR

NO-4

STAIR

NO-5

HAC

SE150

TRIAGE

SE151

SOCIAL

WORKER

SE152

MINOR

TREATMENT

SE153

CONFERENCE

RM

SE155

ADVOCATE

OFFICE

S109 S108

RECEPTION

SW102A

NURSE

STATION

SW103

PROVIDER

STATION

SW104

EXAM

RM

SW105

EXAM

RM

SW106

EXAM

RM

SW107

SW108

EXAM

RM

SW109SW110

EXAM

RM

SW113

EXAM

RM

SW114

TOILET

SW115A

CLINICAL

PHARMACIST

SW116

TOILET

SW117

TOILET

SW118

SW119

TREATMENT

SW102B

POLICE

AMBULANCE

ENTRANCE

SE156

PASSAGE

SE105

ACTIVE

STORAGE

SE113

OUTPATIENT

PHARMACY

SE114

MALE

TOILET

S111

WOMENS

TOILET

S110

OFFICE

N114

IMAGING

NE110

TREATMENT

NE111

TREATMENT

NE112

RECEPTION

NE113

TREATMENT

NE103

CORR

NE1COR.1

CORR

NE1COR.1

CORR

NW1C0R.1

CORR

SE1COR.1

CORR

S1COR.1

CORR

SW1C0R.2

CORR

SW1C0R.1

CORR

S1C0R.2

C O

R R

C 1C

0R .3

C O

R R

C 1C

0R .2

41 2 5 6 7 8 9 10 11 13 14 15 16 17 18 20 21 22 23 24 25 26 27 28

A

B

C

D

E

F

G

H

J

K

L

M

N

P

R

S

T

U

V

W

X

Y

Z

AA

BB

CC

DD

TR

1-N118

LOBBY

1-001

CORR

1-C1COR.1

CORR

1-N1COR.1

OFFICE

1-N117

CASHIER

1-N116OFFICE

1-N115

VOLUNTEER

AREA

1-N121

1-T-101-TR

TR-01-1

1-T-101-TR

EXISTING SECURITY

PANELS

TRUE

NORTH

PLAN

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

636A-21-701

9/2/2022

EHRM INFRASTRUCTURE

UPGRADES

CONSTRUCTION

DOCUMENTS

GRAND ISLAND, NE

Alesia Architecture P.C.

3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941

Shaffer Stevens & Schaap P.C.

1070 Howard Street Omaha, NE 68102 Phone: (402) 455-7698

Specialized Engineering Solutions 10360 Ellison Circle Omaha, NE 68134 Phone: (402) 991-5520

IMEG Corp.

2882 106th Street Des Moines, IA 50322 Phone (515) 334-4324

Thompson, Dreessen & Dorner, Inc.

10836 Old Mill Rd Omaha, NE 68154 Phone: (402) 330-8860

AMI Environmental Inc 8802 S 135th Street Omaha, NE 68138 Phone: (402) 397-5001

3 4

10 11

6 191

KEYPLAN

B

IM

/2

-1 a

-2

-7

V A

G ra n d I s la n d

E H

R M

/6

A

-7

.B

T e c h

C

.r v t

/1

/2

:2

:3

P M

1-T-101

FIRST FLOOR PLAN - TECHNOLOGY - BLDG

PND DJJ

1/16" = 1'-0"

FIRST FLOOR PLAN - TECHNOLOGY

KEYNOTES:

1. "LEG A" BACKBONE CABLING PATHWAY.

2. "LEG B" BACKBONE CABLING PATHWAY.

3.…

This is the start of the file's text. The full file is on GovTribe.