Attachment 5 - 549-21-700 - Construction Bid Drawings_Volume 3.pdf
PDF 25 MB Posted
- Solicitation number
- 36C77625R0093
About this file
This document is a set of construction bid drawings (Volume 3) for telecommunications demolition and infrastructure work at the Dallas VA Medical Center. The drawings are dated March 17, 2025, and are part of project 549-21-700 for EHRM Infrastructure Upgrades located at 4500 S Lancaster Road, Dallas, Texas 75216. The drawings include demolition floor plans for telecommunications systems across multiple buildings (B2J, B3, B4, B5, B6, B7, B8, B9, B11, B13, and B43) at various levels including basements and upper floors.
The drawings specify existing telecommunications infrastructure to remain in place, new telecommunications rooms and enclosures to be created, and equipment to be removed. General notes indicate that the site is an active working environment requiring coordination with VA campus operations for any system shutdowns, with at least twenty working days' notice required. The contractor must field-verify existing conditions and coordinate with the contracting officer and engineer of record where conditions deviate from contract documents. The owner retains first salvage rights for all demolished devices and materials. Work includes removing existing faceplates and cabling back to source while preserving pathways and backboxes for reuse where noted, and demolishing existing cable tray except where reuse is specified. The design team includes Spur Design LLC as architect and MEP/Telecom engineer, with multiple consultants for civil, structural, fire protection, industrial hygiene, and security disciplines.
View the file
Other files
Show all 36
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
U P
U P
U P
2D/1V
2D/1V2D/1V 2D/1V2D/1V
2D/1V 2D/1V
2D/1V2D/1V 2D/1V 2D/1V
2D/1V 2D/1V 2D/1V
2D/1V 2D/1V 2D/1V
2D/1V2D/1V2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V2D/1V
2D/1V 2D/1V 2D/1V 2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/2V2D/1V 2D/1V
2D/1V
2D/1V 2D/1V
2D
2D
2D 2D
2D
1D
1D
1D
2D
2D 2D 2D
2D2D2D
1D
1D
1D
2D 2D 2D
1D1D1D
1D
1D 1D 1D
1D1D 1D1D1D1D
1D
1D
1V
1D
2D
1D 1V
1D1D
1V
1V
2V
1V
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
1D1D1D
1D 1D 1D
1D1D1D
1D 1D 1D
1D 1D 1D 1D 1D 1D
1D
1D
1D
1D
2D/1V
1TV
1D/1V
2D/1V
2D/1V
WAP
2D/1V
2D/1V 1D
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V +36"
2D/1V
2D/1V +36"
1D
2D/1V
2D/1V
1D
2D/1VWAP
2D/1V 2D/1V2D/1V +36"
2D/1V2D/1V +36"
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V +36"2D/1V +36"
2D/1V
2D/1V 2D/1V +36"
2D/1V
2D/1V 2D/1V +36"
2D/1V
2D/1V 2D/1V +36"
2D/1V
2D/1V 2D/1V +36"
2D/1V
2D/1V 2D/1V +36"
2D/1V
2D/1V 2D/1V +36"
2D/1V
2D/1V 2D/1V +36"
2D/1V
2D/1V
2D/1V +36"
2D/1V
2D/1V 2D/1V +36"
2D/1V
2D/1V 2D/1V +36"
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V +36"
2D/1V
2D/1V +36"
2D/1V
2D/1V +36" 2D/1V
2D/1V +36"
2D/1V
2D/1V +36"
2D/1V
2D/1V +36"
1D
2D/1V 2D/1V2D/1V2D/1V2D/1V
2D/1V2D/1V
2D/1V
2D/1V
2D/1V
2D/1V2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
1 1 1
EX. COMM
3-1A
92 SF
EX. COMM
3-2A
95 SF
2D/1V
2D/1V
2D/1V
1V +48"
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
1V +48"
2D/1V
2D/1V
2D/1V
2D/1V 1V +48"2D/1V
2D/1V
WAP
WAP
WAP WAP
WAP
WAP
WAP WAP
WAP
WAP
WAP
WAP
2D/1V
2D
CORRIDOR
C1B-18
1 BR
3A-235C
1 BR
3A-235D
1 BR
3A-235E
1 BR
3A-235F
1 BR
3A-235G
MULTI BR
3A-242
S EQUIP
3A-240
EQUIP
3A-236
LINEN
3A-235K
MED
3A-235J
3A-235H
MULTI PURP
3A-154
MULTI PURP
3A-152
MULTI PURP
3A-150
MULTI PURP
3A-148
MULTI PURP
3A-144
MULTI PURP
3A-138
MULTI PURP
3A-136
MULTI PURP
3A-134
MULTI PURP
3A-132
MULTI PURP
3A-126
MULTI PURP
3A-124
MULTI PURP
3A-120
MULTI PURP
3A-118
MULTI PURP
3A-116
MULTI PURP
3A-114
CHIEF
3A-308 PREP
3A-304
CH CHEM
3A-302
DIAL REPO
3A-300
HOUSE STAFF
3A-310
PHYS
3A-312
PHYS
3A-314
PHYS
3A-316
PHYS
3A-318
INTERNS
3A-320
ELEC ROOM
3-2B
STAIRWELL-2
S-234
EXAM
3A-156
EXAM
3A-158
OFFICE
3A-157
MEDICATION
3A-149
EXAM
3A-160
UTILITY
C3A-6D
HAC
3A-146
HAC
3A-145
LAB
3A-303
WAITING ROOM
C3A-23A
OFFICE
C3A-23A
UTILITY
3A-301
OFFICE
3A-301
OFFICE
3A-227
TR
3A-317
HAC
3A-225
BREAK ROOM
3A-222
STORAGE
3A-236
OFFICE
3A-236A
OFFICE
3A-234
TRAINING ROOM
3A-230
EXAM
3A-228
OFFICE
3A-226
OFFICE
3A-224
LOCKER ROOM
3A-222A
LOCKER ROOM
3A-222B
STORAGE
3A-214
STORAGE
3A-212
TOILET, UNISEX
3A-210
STAIRWELL-9
S-93
STORAGE
3A-322 STORAGE
3A-322
STORAGE
3A-335A
STORAGE
3A-335
ELEV LOBBY
3A-335
THERAPY
3A-137
TOILET
3A-139A
OFFICE
3A-133
PROCEDURE
3A-139
MEDICATION
3A-131B
EXAM
3A-127
EXAM
3A-128
TOILET
3A-121
UTILITY
3A-123
MULTI PURP
3A-115
MULTI PURP
3A-113
CORRIDOR
C3A-11
UTLITY
3A-334
RASH HOLDING
3A-330
EXAM
3A-111
COMPUTER
3A-309
42D
EXAM
3A-160
CORRIDOR
C3A-9
EXAM
3A-161 RECEPTION
C3A-6D
CORRIDOR
C3A-8
MULTIPURP
3A-141
CONFERENCE
3A-140
OFFICE
3A-132
OFFICE
3A-131
CORRIDOR
C3A-7
OFFICE
3A-130
CORRIDOR
C3A-5
RECEPTION
C3A-6A
CORRIDOR
C3A-6
MULTIPURP
3A-109
EXAM
3A-129
EXAM
3A-110
EXAM
3A-108
MULTIPURP
3A-106
PROCEDURE
3A-338
CORRIDOR
C3A-17
UTILITY
3A-123
EXAM
3A-112
HAC
3A-336
ELEV LOBBY
BB-101
CORRIDOR
C3A-29
WAITING
3A-204
OFFICE
3A-206
OFFICE
3A-208
CORRIDOR
C3A-19
CORRIDOR
C3A-10
/1 TND123
/1 TND123
CORRIDOR
C3A-21
CORRIDOR
C3A-23
CORRIDOR
C3A-25
CORRIDOR
C3A-24
NURSING STATION
3A-235
TOILET, STAFF
3A-237
TELECAR
3A-236B
CORRIDOR
C3A-26
STAIRWELL 1
S-13
KEY PLAN
N
22J
TT54
TT51
TT49
TT46
TT47
TT48
TT87
TT55
L A
N C
A S
T E
R R
O A
D
ANN ARBOR AVENUE
TT53
TT52
TT50
OVERALL PLAN LEGEND
DESCRIPTIONSYMBOL
EXISTING TELECOMMUNICATIONS ROOM/CLOSET TO REMAIN.
NO SPACE WORK REQUIRED.
NEW TELECOMMUNICATIONS ROOM/TE.
EXISTING ROOM TO BE MODIFIED IN PLACE. REFER TO
ARCHITECTURAL FOR EXTENT OF SPACE WORK.
A. DRAWING IS DIAGRAMMATIC IN NATURE AND IS NOT TO BE CONSTRUED
AS ALL INCLUSIVE; FIELD VERIFY EXISTING CONDITIONS AND ADJUST
WORK AS REQUIRED TO EXECUTE SPECIFIED WORK.
B. EXISTING CONDITIONS INDICATED ARE BASED ON GENERAL FIELD
NOTES AND HISTORICAL DATA AND DOCUMENTATION AND ARE FOR
REFERENCE PURPOSES ONLY TO DEFINE SCOPE OF WORK; FIELD
VERIFY ALL CONDITIONS. WHERE CONDITIONS DEVIATE FROM CONTRACT
DOCUMENTS, CONTRACTOR SHALL CORDINATE WITH COR AND EOR.
C. THIS SITE IS AN ACTIVE WORKING ENVIRONMENT; SYSTEMS SHALL NOT
BE SHUTDOWN WITHOUT WRITTEN AUTHORIZATION AND COORDINATION
WITH CAMPUS OPERATIONS AS DIRECTED BY VA; ALL REQUESTS SHALL
BE SUBMITTED IN WRITING A MINIMUM OF TWENTY (20) WORKING-DAYS
PRIOR TO PROPOSED ACTIVITY DATE OR NEED UNLESS DIRECTED
OTHERWISE.
D. SEE T-001 TELECOMMUNICATIONS COVER SHEET FOR SYMBOLS
DEFINITION:
1. SYMBOLS GRAYED/ HALFTONE: INDICATED FOR REFERENCE AND/OR
INDICATING EXISTING UNLESS SPECIFICALLY NOTED OTHERWISE.
2. SYMBOLS DASHED OR SPECIFICALLY KEYED NOTED: INDICATES
DEMOLITION WORK.
E. OWNER SHALL HAVE FIRST SALVAGE RIGHTS FOR ANY DEMOLISHED
DEVICES OR MATERIAL.
F. ALL PATHWAYS ARE EXISTING UNLESS NOTED OTHERWISE.
G. REMOVE EXISTING FACEPLATE FROM WORK AREA OUTLET. REMOVE
EXISTING CABLING BACK TO SOURCE LEAVING EXISTING PATHWAY AND
BACKBOX IN PLACE FOR REUSE UNLESS NOTED OTHERWISE.
H. DEMOLISH EXISTING SPLINE TYPE CABLE TRAY TO BE EXCEPT WHERE IT
IS DETERMINED THAT THE EXISTING IS TO BE REUESED UNLESS NOTED
OTHERWISE.
TELECOMMUNICATIONS DEMOLITION GENERAL NOTES
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
DRAWING TITLE PROJECT TITLE
LOCATION
DATE CHECKED DRAWN
PROJECT NUMBERCONSULTANTS:
DRAWING #
VA HEALTH CARE SYSTEM APPROVAL:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. BR 2171 EXP. 09/30/2025
ENGR REG. NO. F-17591 EXP. 02/28/2025
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TELECOM
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
RATED ENGINEERING
609 S. KELLY AVENUE, SUITE H2
EDMOND, OK 73003
(405) 856-2965
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
STRUCTURAL ENGINEER
STAND STRUCTURAL ENGINEERING
8234 ROBINSON STREET
OVERLAND PARK, KS 66204
(913) 214-2169
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
DRAWING NUMBER
BUILDING NUMBER
/1
/2
:1
:0
B2J - LEVEL 3 AREA C -
TELECOMMUNICATIONS FLOOR PLAN -
DEMOLITION
MDT 342 OF 478KGH
FINAL BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES DALLAS, TX
03/17/2025
549-21-700
DALLAS VA MEDICAL CENTER
4500 S LANCASTER RD
DALLAS, TX 75216
TND124
SPUR #: 2302
N
1/16" = 1'-0"
B2J - LEVEL 3 AREA C - TELECOMMUNICATIONS FLOOR PLAN - DEMOLITION1
1 EXISTING WORK AREA OUTLETS MOUNTED WITHIN SYSTEMS FURNITURE TO
REMAIN. COORDINATE MOUNTING AND PATHWAY ROUTING WITH FURNITURE
AND EQUIPMENT PLANS.
2 EXISTING TELECOMMUNICATIONS EQUIPMENT IN CLOSET 3-1A TO REMAIN.
3 EXISTING TELECOMMUNICATIONS EQUIPMENT IN CLOSET 3-2A TO REMAIN.
4 EXISTING DATA FOR BUILDING AUTOMATION SYSTEM TO REMAIN.
TELECOMMUNICATIONS KEYNOTES
No. REVISION DESCRIPTION DATE
4D
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 1D
2D/1V
2D
2D/1V
2D/1V
1D/1V
2D/1V
2D/1V
WAP
1D
1D
2D/1V
2D/1V
1V
1D
1D/1V
1D/1V
1D/1V
1D/1V
2D 2D2D 2D 2D
2D
2D/1V +36"
2D
2D 2D/1V2D
2D
2D
2D
2D
2D/1V
2D
2D/1V
2D/1V
2D/1V +36"
2D 2D/1V 2D
2D/1V
2D 2D
2D/1V 2D2D 2D/1V
2D/1V +36"
2D 2D/1V
2D/1V +36"
2D/1V2D/1V
2D2D/1V
2D/1V
2D/1V
2D/1V +36"
2D2D
2D/1V +36"
2D/1V2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V2D/1V2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
TR
5B-646
181 SF
EX. COMM
5-4A
90 SF
EX. COMM
5-5A
92 SF
EX. COMM
5-6A
92 SF
TR
5B-313
177 SF
EX. COMM
5-7A
84 SF
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
1V +48"
2D/1V
2D/1V 2D/1V
2D/1V
1V +48"
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V2D/1V2D/1V
2D/1V
1V +48"
2D/1V
2D/1V
2D/1V
2D/1V
1D
2D/1V2D/1V
2D/1V
2D/1V2D/1V
2D/1V2D/1V
2D/1V2D/1V
1V +48"
2D/1V
2D/1V
1V +48"
2D/1V
2D/1V
2D/1V
2D/1V2D/1V
2D/1V
2D/1V
2D/1V
1V +48"
2D/1V 2D/1V
2D/1V
1V +48"
2D/1V
2D/1V
2D/1V
1V +48"
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V2D/1V2D/1V
PATIENT RM.
5B-202M
PATIENT RM.
5B-202L
PATIENT RM.
5B-202K
PATIENT RM.
5B-202J
OFFICE
5B-228
OFFICE
5B-230
OFFICE
5B-232
OFFICE
5B-234
OFFICE
5B-236
PATIENT RM.
5B-252X
PATIENT RM.
5B-252W
PATIENT RM.
5B-252V
PATIENT RM.
5B-252U
PATIENT RM.
5B-252T
PATIENT RM.
5B-252S
PATIENT RM.
5B-252R
PATIENT RM.
5B-252Q
PATIENT RM.
5B-252P
SICU NURSING
STATION
5B-202
TOILET, UNISEX
5B-202E
MEDICATION
5B-202F
PATIENT RM.
5B-202G
PATIENT RM.
5B-202H
CLOSET
5B-222
HAC
5B-223
UTILITY RM SOILED
5B-202A
CORRIDOR
C5B-39
ON-CALL BEDROOM
5B-229
ON-CALL BATH
5B-229A
SICU/TICU
SATELLITE PHARM.
5B-243
LINEN RM SOILED
5B-240
STORAGE, EQUIP
5B-242
STORAGE, OXYGEN
5B-244
ON-CALL BEDROOM
5B-229
ON-CALL BATH
5B-229A
OFFICE
5B-238
LAB
5B-238
OFFICE
5B-248
CONFERENCE RM
5B-248
STORAGE
5B-251
TICU NURSING
STATION
5B-252
KITCHEN
5B-252A
KITCHEN
NOURISHMENT
5B-252B
UTILITY RM CLEAN
5B-252A
WORKSTATION
5B-252D
WORKSTATION
5B-252E
MEDICATION
5B-252F
STORAGE EQUIP.
5B-252G
TOILET, UNISEX
5B-202E
STORAGE
5B-252E
UTILITY RM SOILED
5B-252J
HAC
5B-252K
PATIENT RM.
5B-252L
ANTE RM
5B-252N
ANTE RM
5B-252M
ELECTRICAL RM
5-7B
SERVICE BAY 7
5-7
CORRIDOR
C5B-46 HAC
5B-273
STAIRWELL
S-75
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
ELECTRICAL RM
5-6B
SERVICE BAY
5-6
STAIRWELL
S-65
ELECTRICAL RM
5-5B
SERVICE BAY
5-5
ELECTRICAL RM
5-4B
SERVICE BAY
5-4
STAIRWELL
S-55
STAIRWELL
S-45
VESTIBULE
5-5C
BREAKROOM
5B-271
LOCKER RM/MALE
5B-271B
LOCKER
RM/FEMALE
5B-271
BREAKROOM
5B-271
S T
O R
A G
E , O
X Y
G E
N
5B -3
S T
O R
A G
E , O
X Y
G E
N
5B -3
BEDROOM
5B-315
BEDROOM
5B-317
BEDROOM
5B-315A
BEDROOM
5B-317A BEDROOM
5B-319
BEDROOM
5B-319A
BEDROOM
5B-319
OFFICE
5B-312
OFFICE
5B-311
OFFICE
5B-310
OFFICE
5B-309
OFFICE
5B-308
OFFICE
5B-306
OFFICE
5B-259
OFFICE
5B-307
CORRIDOR
5B-300
OFFICE
5B-305
OFFICE
5B-257
OFFICE
5B-304
OFFICE
5B-303
TOILET, MALE
STAFF
5B-255
TOILET, FEMALE
STAFF
5B-253
LOCKER RM, MALE
STAFF
5B-255A
LOCKER RM,
FEMALE STAFF
5B-253A
OFFICE
5B-302
UTILITY RM SOILED
5B-202A HAC
5B-413
OPERATING RM 7
5B-407D
OPERATING RM 8
5B-407C
OPERATING RM 9
5B-407A
OPERATING RM 6
5B-407F
OPERATING RM 4
5B-408B
OPERATING RM 3
5B-408G
OPERATING RM 1
5B-408D
OPERATING RM 2
5B-408E
CLEAN OUTER
CORRIDOR
C5B-31B
CLEAN OUTER
CORRIDOR
C5B-31A
SUB STERILE AREA
5B-407D1
SCRUB RM
5B-407E
SCRUB RM
5B-407C1
CORRIDOR
5B-407
CLEAN CORE
CORRIDOR
5B-406
CLEAN CORE
CORRIDOR
5B-408
FROZEN SECTION
5B-410
OR LAB
5B-408A
SUB STERILE AREA
5B-406C1
SUB STERILE AREA
5B-406A1
EQUIP CONTROL RM
5B-406A2
WORKSTATION
5B-407G
EQUIPMENT AREA
5B-407H
STORAGE
5B-406E
HAC
5B-406F
SCRUB RM
5B-408F
STERILE AREA
5B-406C1
CLEAN OUTER
CORRIDOR
C5B-31
LINEN CONTROL,
CLEAN
C5B-31A
HAC
5B-406F
STERILE AREA
5B-408D1
ANETHESIA
SATELLITE CART
C5B-35A
STORAGE
5B-408C
LINEN CONTROL,
CLEAN
C5B-31A
WAP
WAPWAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
2D/1V
2D
2D
2D
2D
1D
OFFICE
5B-676
OFFICE
5B-674
OFFICE
5B-672
OFFICE
5B-670
OFFICE
5B-668
CUBICAL
5B-636
OFFICE
5B-634
LAB
5B-633
CORRIDOR
C5B-17
ECHO
5B-642
OFFICE
5B-666
UTILITY
5B-664
OFFICE
5B-662
PROCEDURE
5B-663
OFFICE
5B-675
CONTROL
5B-661
STORAGE
5B-659A
CARDIAC LAB
5B-659
OFFICE
5B-503
OFFICE
5B-503
UTILITY
5B-500C
ISO RM
5B-500E
ANTE
5B-500D
OFFICE
5B-500F
ANTE
5B-500G
OFFICE
5B-500H
BREAKROOM
5B-500J
BEDROOM
5B-322
BEDROOM
5B-323
BEDROOM
5B-324
LINEN
5B-500Q
MEDICATION
5B-500P
HAC
5B-500L
STORAGE
5B-500M
ISO RM
5B-500B
OFFICE
5B-504
OFFICE
5B-505
WORKROOM
5B-504A
VIEWING
5B-657
UTILITY
5B-655
STORAGE
5B-653
X-RAY
5B-647
CONTROL
5B-647A
DRESSING
5B-647A1
/1 TND126
/1 TND126
KEY PLAN
N
22J
TT54
TT51
TT49
TT46
TT47
TT48
TT87
TT55
L A
N C
A S
T E
R R
O A
D
ANN ARBOR AVENUE
TT53
TT52
TT50
OVERALL PLAN LEGEND
DESCRIPTIONSYMBOL
EXISTING TELECOMMUNICATIONS ROOM/CLOSET TO REMAIN.
NO SPACE WORK REQUIRED.
NEW TELECOMMUNICATIONS ROOM/TE.
EXISTING ROOM TO BE MODIFIED IN PLACE. REFER TO
ARCHITECTURAL FOR EXTENT OF SPACE WORK.
A. DRAWING IS DIAGRAMMATIC IN NATURE AND IS NOT TO BE CONSTRUED
AS ALL INCLUSIVE; FIELD VERIFY EXISTING CONDITIONS AND ADJUST
WORK AS REQUIRED TO EXECUTE SPECIFIED WORK.
B. EXISTING CONDITIONS INDICATED ARE BASED ON GENERAL FIELD
NOTES AND HISTORICAL DATA AND DOCUMENTATION AND ARE FOR
REFERENCE PURPOSES ONLY TO DEFINE SCOPE OF WORK; FIELD
VERIFY ALL CONDITIONS. WHERE CONDITIONS DEVIATE FROM CONTRACT
DOCUMENTS, CONTRACTOR SHALL CORDINATE WITH COR AND EOR.
C. THIS SITE IS AN ACTIVE WORKING ENVIRONMENT; SYSTEMS SHALL NOT
BE SHUTDOWN WITHOUT WRITTEN AUTHORIZATION AND COORDINATION
WITH CAMPUS OPERATIONS AS DIRECTED BY VA; ALL REQUESTS SHALL
BE SUBMITTED IN WRITING A MINIMUM OF TWENTY (20) WORKING-DAYS
PRIOR TO PROPOSED ACTIVITY DATE OR NEED UNLESS DIRECTED
OTHERWISE.
D. SEE T-001 TELECOMMUNICATIONS COVER SHEET FOR SYMBOLS
DEFINITION:
1. SYMBOLS GRAYED/ HALFTONE: INDICATED FOR REFERENCE AND/OR
INDICATING EXISTING UNLESS SPECIFICALLY NOTED OTHERWISE.
2. SYMBOLS DASHED OR SPECIFICALLY KEYED NOTED: INDICATES
DEMOLITION WORK.
E. OWNER SHALL HAVE FIRST SALVAGE RIGHTS FOR ANY DEMOLISHED
DEVICES OR MATERIAL.
F. ALL PATHWAYS ARE EXISTING UNLESS NOTED OTHERWISE.
G. REMOVE EXISTING FACEPLATE FROM WORK AREA OUTLET. REMOVE
EXISTING CABLING BACK TO SOURCE LEAVING EXISTING PATHWAY AND
BACKBOX IN PLACE FOR REUSE UNLESS NOTED OTHERWISE.
H. DEMOLISH EXISTING SPLINE TYPE CABLE TRAY TO BE EXCEPT WHERE IT
IS DETERMINED THAT THE EXISTING IS TO BE REUESED UNLESS NOTED
OTHERWISE.
TELECOMMUNICATIONS DEMOLITION GENERAL NOTES
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
DRAWING TITLE PROJECT TITLE
LOCATION
DATE CHECKED DRAWN
PROJECT NUMBERCONSULTANTS:
DRAWING #
VA HEALTH CARE SYSTEM APPROVAL:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. BR 2171 EXP. 09/30/2025
ENGR REG. NO. F-17591 EXP. 02/28/2025
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TELECOM
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
RATED ENGINEERING
609 S. KELLY AVENUE, SUITE H2
EDMOND, OK 73003
(405) 856-2965
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
STRUCTURAL ENGINEER
STAND STRUCTURAL ENGINEERING
8234 ROBINSON STREET
OVERLAND PARK, KS 66204
(913) 214-2169
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
DRAWING NUMBER
BUILDING NUMBER
/1
/2
:1
:1
B2J - LEVEL 5 AREA A -
TELECOMMUNICATIONS FLOOR PLAN -
DEMOLITION
MDT 343 OF 478KGH
FINAL BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES DALLAS, TX
03/17/2025
549-21-700
DALLAS VA MEDICAL CENTER
4500 S LANCASTER RD
DALLAS, TX 75216
TND125
SPUR #: 2302
N
1/16" = 1'-0"
B2J - LEVEL 5 AREA A - TELECOMMUNICATIONS FLOOR PLAN - DEMOLITION1
1 EXISTING DATA FOR BUILDING AUTOMATION SYSTEM TO REMAIN.
2 EXISTING DATA FROM CEILING TO REMAIN.
3 EXISTING TELECOMMUNICATIONS EQUIPMENT IN CLOSET 5-4A TO REMAIN.
4 NEW TELECOMMUNICATIONS ROOM.
5 EXISTING TELECOMMUNICATIONS EQUIPMENT IN CLOSET 5-5A TO REMAIN.
6 EXISTING TELECOMMUNICATIONS EQUIPMENT IN CLOSET 5-6A TO REMAIN.
7 EXISTING TELECOMMUNICATIONS EQUIPMENT IN CLOSET 5-7A TO REMAIN.
S T-02A
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
WAP
WAP
1V
1D1V
1V
WAP WAPWAP
2D/1V
2D/1V
4D/2V
2D/1V
2D/1V
2D/1V
2D/1V2D/1V2D/1V2D/1V2D2D
2D/1V 2D/1V
2D/1V
2V
2D/1V
2D/1V
2D/1V
2V
4D/1V
2V
4D/1V
1D/1V2D
2D
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
WAP
WAP
WAP
WAP
WAP
1V
1V1V1V
1D 1D 1D
1V
2D/1V
2D/1V
1V 1V
1D/1V
2D/1V
2D/1V 2D
2D/1V
2D/1V
2D/1V2D/1V
2D/1V
2D 2D WAP
2D/1V
2D/1V
2D/1V
2D/1V2D/1V
2D
2D
2D
2D/1V +36"
2D/1V 2D/1V
2D/1V 2D/1V
2D
2D/1V +36"
2D/1V 2D/1V
2D/1V
2D/1V +36"
2D
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
WAP
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V2D/1V
2D/1V
2D/1V
2D/1V
2D/1V2D/1V
2D/1V2D/1V
2D/1V2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
TR
5B-138
150 SF
EX. COMM
5-3A
92 SF
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
1V +48"
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
1V +48"
2D/1V 2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
1V +48"
PATIENT RM.
5B-202T
PATIENT RM.
5B-202S
PATIENT RM.
5B-202R
PATIENT RM.
5B-202Q
PATIENT RM.
5B-202P
PATIENT RM.
5B-202N
ANTE RM.
5B-202U
ANTE RM.
5B-202V
PATIENT RM.
5B-202W
PATIENT RM.
5B-202X
PATIENT RM.
5B-202Y
CLEAN LINEN RM
5B-202B
KITCHEN
NOURISHMENT
5B-202A
UTILITY RM CLEAN
5B-202A
WORKSTATION
5B-202C
CORRIDOR
C5B-28
CONSULTATION
5B-200
ELECTRICAL RM.
5-3B
SERVICE BAY
5-3
SERVICE BAY
5-3C
CORRIDOR
C5B-8
CLEAN OUTER
CORRIDOR
C5B-27
CLEAN OUTER
CORRIDOR
C5B-30
HAC
5B-411
STORAGE,
STRETCHER
5B-411
STERILE RM
5B-405C1
OPERATING RM 12
5B-405C
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
OPERATING RM 11
5B-405E
OPERATING RM 10
5B-405G
OPERATING RM 5
5B-407C
OPERATING RM 13
5B-405B1
LOCKER RM/MALE
5B-402A
CLOTHING RM
5B-403A
CLOTHING RM
5B-403
TOILET/MALE STAFF
5B-402
CHART/DICTAT.
5B-401A
SURGICAL LOUNGE
5B-401
CHART/DICTAT.
5B-401A
TOILET/FEMALE
STAFF
5B-400
LOCKER
RM/FEMALE
5B-400A
STERILE AREA
5B-404A
STORAGE, EQUIP
5B-404C
CLEAN CORE
CORRIDOR
5B-404
WORKROOM
5B-404B
STORAGE
5B-408C
SCRUB RM
5B-406B
CONTROL RM
5B-406A
CLEAN CORE
CORRIDOR
5B-405
ALCOVE, CRASH
CART
5B-405H
STERIL AREA
5B-407A4
SCRUB RM
5B-405F
SUB STERILE AREA
5B-406A1
SCRUB RM
5B-405D
PLASTER RM.
5B-405E1
SCRUB RM
5B-405B
X-RAY RM
5B-405B3
STORAGE
5B-405B3A
LINEN RM. CLEAN
5B-405B2
UTILITY RM, SOILED
5B-412
STORAGE
5B-405A
PHARMACY
5B-405A
CORRIDOR
C5B-7
OFFICE
5B-143
STORAGE
C5B-7OFFICE, CHIEF
5B-141
COPY RM
C5B-7
CORRIDOR
5B-101B
OFFICE
5B-139
SPECIAL
PROCEDURE RM
5B-139
STAFF TOILET
5B-139
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
OFFICE
5A-202
SERVER ROOM
5B-600
CORRIDOR
C5A-3
ELEV LOBBY
C5A-1
TOILET
5B-603
TOILET
5B-601
OFFICE
5B-103A
STUDY ROOM
5B-103
KITCHEN
5B-102
TOILET
5A-100
TOILET
5B-100
OFFICE
5A-102
CORRIDOR
C5A-2A
RECEPTION
5B-101
DRESSING
5B-120A
LOUNGE
5B-120
OFFICE, JOINED
5B-124
OFFICE
5B-130
OFFICE
5B-132
OFFICE
5B-134
OFFICE
5B-136
WAITING AREA
C5B-1A
WAP
2D
2D/1V
2D/1V
OFFICE
5B-632
OFFICE
5B-630
EXAM
5B-628
LAB
5B-626
LAB
5B-624
RECEPTION
5B-622
CARDIOLOGY
C5B-13A
OFFICE
5B-616
STAIRWAY-8
S-85
PHARMACY
5B-612
OFFICE
5B-608
OFFICE
5B-610
EXAM
5B-623
EXAM
5B-625
EKG
5B-627
LOUNGE
5B-629
LAB
5B-631
PATIENT
5B-705
OFFICE
5B-710
OFFICE
5B-708 PATIENT
5B-705
OFFICE
5B-706
OFFICE
5B-707
OFFICE
5B-709
LINEN
5B-700 OFFICE
5B-703
HAC
5B-704
STORAGE
5B-702
STORAGE
5B-107
ELEVATOR LOBBY
C5B-11
VESTIBULE
5B-108B
RECOVERY
5B-115
/1 TND125
/1 TND125
CLEAN OUTER
CORRIDOR
C5B-27
CORRIDOR
C5B-26
KEY PLAN
N
22J
TT54
TT51
TT49
TT46
TT47
TT48
TT87
TT55
L A
N C
A S
T E
R R
O A
D
ANN ARBOR AVENUE
TT53
TT52
TT50
OVERALL PLAN LEGEND
DESCRIPTIONSYMBOL
EXISTING TELECOMMUNICATIONS ROOM/CLOSET TO REMAIN.
NO SPACE WORK REQUIRED.
NEW TELECOMMUNICATIONS ROOM/TE.
EXISTING ROOM TO BE MODIFIED IN PLACE. REFER TO
ARCHITECTURAL FOR EXTENT OF SPACE WORK.
A. DRAWING IS DIAGRAMMATIC IN NATURE AND IS NOT TO BE CONSTRUED
AS ALL INCLUSIVE; FIELD VERIFY EXISTING CONDITIONS AND ADJUST
WORK AS REQUIRED TO EXECUTE SPECIFIED WORK.
B. EXISTING CONDITIONS INDICATED ARE BASED ON GENERAL FIELD
NOTES AND HISTORICAL DATA AND DOCUMENTATION AND ARE FOR
REFERENCE PURPOSES ONLY TO DEFINE SCOPE OF WORK; FIELD
VERIFY ALL CONDITIONS. WHERE CONDITIONS DEVIATE FROM CONTRACT
DOCUMENTS, CONTRACTOR SHALL CORDINATE WITH COR AND EOR.
C. THIS SITE IS AN ACTIVE WORKING ENVIRONMENT; SYSTEMS SHALL NOT
BE SHUTDOWN WITHOUT WRITTEN AUTHORIZATION AND COORDINATION
WITH CAMPUS OPERATIONS AS DIRECTED BY VA; ALL REQUESTS SHALL
BE SUBMITTED IN WRITING A MINIMUM OF TWENTY (20) WORKING-DAYS
PRIOR TO PROPOSED ACTIVITY DATE OR NEED UNLESS DIRECTED
OTHERWISE.
D. SEE T-001 TELECOMMUNICATIONS COVER SHEET FOR SYMBOLS
DEFINITION:
1. SYMBOLS GRAYED/ HALFTONE: INDICATED FOR REFERENCE AND/OR
INDICATING EXISTING UNLESS SPECIFICALLY NOTED OTHERWISE.
2. SYMBOLS DASHED OR SPECIFICALLY KEYED NOTED: INDICATES
DEMOLITION WORK.
E. OWNER SHALL HAVE FIRST SALVAGE RIGHTS FOR ANY DEMOLISHED
DEVICES OR MATERIAL.
F. ALL PATHWAYS ARE EXISTING UNLESS NOTED OTHERWISE.
G. REMOVE EXISTING FACEPLATE FROM WORK AREA OUTLET. REMOVE
EXISTING CABLING BACK TO SOURCE LEAVING EXISTING PATHWAY AND
BACKBOX IN PLACE FOR REUSE UNLESS NOTED OTHERWISE.
H. DEMOLISH EXISTING SPLINE TYPE CABLE TRAY TO BE EXCEPT WHERE IT
IS DETERMINED THAT THE EXISTING IS TO BE REUESED UNLESS NOTED
OTHERWISE.
TELECOMMUNICATIONS DEMOLITION GENERAL NOTES
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
DRAWING TITLE PROJECT TITLE
LOCATION
DATE CHECKED DRAWN
PROJECT NUMBERCONSULTANTS:
DRAWING #
VA HEALTH CARE SYSTEM APPROVAL:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. BR 2171 EXP. 09/30/2025
ENGR REG. NO. F-17591 EXP. 02/28/2025
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TELECOM
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
RATED ENGINEERING
609 S. KELLY AVENUE, SUITE H2
EDMOND, OK 73003
(405) 856-2965
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
STRUCTURAL ENGINEER
STAND STRUCTURAL ENGINEERING
8234 ROBINSON STREET
OVERLAND PARK, KS 66204
(913) 214-2169
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
DRAWING NUMBER
BUILDING NUMBER
/1
/2
:1
:2
B2J - LEVEL 5 AREA B -
TELECOMMUNICATIONS FLOOR PLAN -
DEMOLITION
MDT 344 OF 478KGH
FINAL BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES DALLAS, TX
03/17/2025
549-21-700
DALLAS VA MEDICAL CENTER
4500 S LANCASTER RD
DALLAS, TX 75216
TND126
SPUR #: 2302
N
1/16" = 1'-0"
B2J - LEVEL 5 AREA B - TELECOMMUNICATIONS FLOOR PLAN - DEMOLITION1
1 EXISTING DATA FOR BUILDING AUTOMATION SYSTEM TO REMAIN.
2 EXISTING TELECOMMUNICATIONS EQUIPMENT IN CLOSET 5-3A TO REMAIN.
3D 4D
2D/1V
2D/1V
2D/1V
2D/1V
4D/2V
2D/1V
2D/1V
1D/1V 1V
3D
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
WAP
WAP
WAP
WAP
1V 2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V2D/1V
2D/1V
2D/1V
2D/1V 2D/1V 2D/1V 2D/1V
2D/1V
2D/1V2D/1V
2D/1V2D/1V
2D/1V
2D/1V 2D/1V 2D/1V 2D/1V 2D/1V 2D/1V 2D/1V 2D/1V 2D/1V 2D/1V 2D/1V 2D/1V 2D/1V 2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
EX. COMM
5-1A
92 SF
TR
5A-227
150 SF
EX. COMM
5-2A
92 SF
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
1V +48"
2D/1V
2D/1V
1V +48"
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
1V +48"
2D/1V
2D/1V
2D/1V
2D/1V 1V +48"
2D/1V2D/1V
1V +48"
2D/1V
WAP
WAP
WAP
WAP WAP
WAP
WAP WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
SERVICE BAY 1
5-1
ELEC
5-1B
FAMILY ROOM
5A-256 CLEAN EQUIPMENT
5A-253
CLEAN EQUIPMENT
5A-252
PATIENT ROOM 2
5A-262
PATIENT TOILET
5A-262A
PATIENT TOILET
5A-268A
PATIENT TOILET
5A-276A
PATIENT TOILET
5A-284A
PATIENT TOILET
5A-290A
PATIENT ROOM 2
5A-264
PATIENT ROOM 2
5A-268
PATIENT ROOM 2
5A-272
PATIENT ROOM
ISOLATION
5A-276A
PATIENT ROOM 2
5A-280
PATIENT ROOM 2
5A-284
PATIENT ROOM 2
5A-286
PATIENT TOILET
5A-264A
PATIENT TOILET
5A-272A
HAC
5A-270
ANTE ROOM
5A-272
PATIENT TOILET
5A-280A
CORRIDOR
C5-A16
PATIENT TOILET
5A-286A
PATIENT ROOM 2
5A-290
PATIENT ROOM 2
5A-250
PATIENT TOILET
5A-250A
PATIENT TOILET
5A-244A
PATIENT TOILET
5A-236B
PATIENT TOILET
5A-230A
PATIENT TOILET
5A-224A
PATIENT ROOM 2
5A-248
PATIENT ROOM
5A-244
PATIENT ROOM
5A-240
PATIENT ROOM
ISOLATION
5A-236A
PATIENT ROOM 2
5A-234
PATIENT ROOM 2
5A-230
PATIENT ROOM 2
5A-228
PATIENT TOILET
5A-248A
PATIENT TOILET
5A-240A
OFFICE
5A-242
ANTE ROOM
5A-236
PATIENT TOILET
5A-234A
CORRIDOR
C5-A19
PATIENT TOILET
5A-228A
PATIENT ROOM 2
5A-224
STAIRWELL-1
S-15
PATIENT ROOM
5A-254
PATIENT TOILET
5A-254A
ON CALL BATH
5A-220A
ON CALL BATH
5A-218A
OFFICE
5A-220
OFFICE
5A-218
CORRIDOR
C5A-18
OFFICE
5A-263
OFFICE
5A-249
STAFF LOUNGE
5A-241B
WORK STATION
C5A16C
TOILET
5A-241A
CHART
5A-241B
MEDICATION
5A-269
NURSE
5A-269
CORRIDOR
C5A-17
KITCHEN
5A-237
CLEAN UTILITY
5A-277
SOILED UTILITY
5A-277CLEAN LINEN
5A-279
OFFICE
5A-233
OFFICE
5A-285
OFFICE
5A-229
NURSE
C5A15A
STORAGE
C5A19A
OFFICE
5A-291
OXYGEN
5A-291
OFFICE
5A-295
HAC
5A-292
SOILED UTILITY
5A-292
FEMALE LOCKER
5A-296
OFFICE
5A-107
PATIENT ROOM
5A-109R
PATIENT ROOM
5A-109Q
PATIENT ROOM
5A-109P
PATIENT ROOM
5A-109N
PATIENT ROOM
5A-109M
PATIENT ROOM
5A-109L
PATIENT ROOM
5A-109K
PATIENT ROOM
5A-124L
PATIENT ROOM
5A-109S
PATIENT ROOM
5A-124K
PATIENT ROOM
5A-124J
PATIENT ROOM
5A-124H
PATIENT ROOM
5A-124G
PATIENT ROOM
5A-124F
PATIENT ROOM
5A-124E
ELEC
5-2B
SERVICE BAY 2
5-2
ISO ROOM
5A-124D
ANTE ROOM
5A-124C
ANTE ROOM
5A-124B
PATIENT ROOM
5A-124A
NURSE
5A-124
WORK AREA
5A-124S
TOILET
5A-124T
MED PREP
5A-124S CLEAN LINEN
5A-124
EQUIPMENT
5A-109H
PATIENT ROOM
5A-124M
PATIENT ROOM
5A-109J
NURSE
5A-109
TOILET
5A-109F
BREAKROOM
5A-109D1
MED PREP
5A-109E
WORK AREA
5A-109E
LINEN CLEAN
5A-109B
ANTE
5A-109T
ANTE
5A-109U
PATIENT ROOM
5A-109V
SERVER ROOM
5A-108
TOILET
5A-216
OFFICE
5A-212
TOILET
5A-214
STAIRWELL-9
S-95
CORRIDOR
C5-A20
LOUNGE
C5A-21
OFFICE
5A-210TOILET
5A-208
ELEV LOBBY
5A297
1V +48"
2D/1V
2D/1V
2D
1V +48" 2D
/1 TND126
/1 TND126
KEY PLAN
N
22J
TT54
TT51
TT49
TT46
TT47
TT48
TT87
TT55
L A
N C
A S
T E
R R
O A
D
ANN ARBOR AVENUE
TT53
TT52
TT50
OVERALL PLAN LEGEND
DESCRIPTIONSYMBOL
EXISTING TELECOMMUNICATIONS ROOM/CLOSET TO REMAIN.
NO SPACE WORK REQUIRED.
NEW TELECOMMUNICATIONS ROOM/TE.
EXISTING ROOM TO BE MODIFIED IN PLACE. REFER TO
ARCHITECTURAL FOR EXTENT OF SPACE WORK.
A. DRAWING IS DIAGRAMMATIC IN NATURE AND IS NOT TO BE CONSTRUED
AS ALL INCLUSIVE; FIELD VERIFY EXISTING CONDITIONS AND ADJUST
WORK AS REQUIRED TO EXECUTE SPECIFIED WORK.
B. EXISTING CONDITIONS INDICATED ARE BASED ON GENERAL FIELD
NOTES AND HISTORICAL DATA AND DOCUMENTATION AND ARE FOR
REFERENCE PURPOSES ONLY TO DEFINE SCOPE OF WORK; FIELD
VERIFY ALL CONDITIONS. WHERE CONDITIONS DEVIATE FROM CONTRACT
DOCUMENTS, CONTRACTOR SHALL CORDINATE WITH COR AND EOR.
C. THIS SITE IS AN ACTIVE WORKING ENVIRONMENT; SYSTEMS SHALL NOT
BE SHUTDOWN WITHOUT WRITTEN AUTHORIZATION AND COORDINATION
WITH CAMPUS OPERATIONS AS DIRECTED BY VA; ALL REQUESTS SHALL
BE SUBMITTED IN WRITING A MINIMUM OF TWENTY (20) WORKING-DAYS
PRIOR TO PROPOSED ACTIVITY DATE OR NEED UNLESS DIRECTED
OTHERWISE.
D. SEE T-001 TELECOMMUNICATIONS COVER SHEET FOR SYMBOLS
DEFINITION:
1. SYMBOLS GRAYED/ HALFTONE: INDICATED FOR REFERENCE AND/OR
INDICATING EXISTING UNLESS SPECIFICALLY NOTED OTHERWISE.
2. SYMBOLS DASHED OR SPECIFICALLY KEYED NOTED: INDICATES
DEMOLITION WORK.
E. OWNER SHALL HAVE FIRST SALVAGE RIGHTS FOR ANY DEMOLISHED
DEVICES OR MATERIAL.
F. ALL PATHWAYS ARE EXISTING UNLESS NOTED OTHERWISE.
G. REMOVE EXISTING FACEPLATE FROM WORK AREA OUTLET. REMOVE
EXISTING CABLING BACK TO SOURCE LEAVING EXISTING PATHWAY AND
BACKBOX IN PLACE FOR REUSE UNLESS NOTED OTHERWISE.
H. DEMOLISH EXISTING SPLINE TYPE CABLE TRAY TO BE EXCEPT WHERE IT
IS DETERMINED THAT THE EXISTING IS TO BE REUESED UNLESS NOTED
OTHERWISE.
TELECOMMUNICATIONS DEMOLITION GENERAL NOTES
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
DRAWING TITLE PROJECT TITLE
LOCATION
DATE CHECKED DRAWN
PROJECT NUMBERCONSULTANTS:
DRAWING #
VA HEALTH CARE SYSTEM APPROVAL:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. BR 2171 EXP. 09/30/2025
ENGR REG. NO. F-17591 EXP. 02/28/2025
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TELECOM
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
RATED ENGINEERING
609 S. KELLY AVENUE, SUITE H2
EDMOND, OK 73003
(405) 856-2965
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
STRUCTURAL ENGINEER
STAND STRUCTURAL ENGINEERING
8234 ROBINSON STREET
OVERLAND PARK, KS 66204
(913) 214-2169
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
DRAWING NUMBER
BUILDING NUMBER
/1
/2
:1
:3
B2J - LEVEL 5 AREA C -
TELECOMMUNICATIONS FLOOR PLAN -
DEMOLITION
MDT 345 OF 478KGH
FINAL BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES DALLAS, TX
03/17/2025
549-21-700
DALLAS VA MEDICAL CENTER
4500 S LANCASTER RD
DALLAS, TX 75216
TND127
SPUR #: 2302
N
1/16" = 1'-0"
B2J - LEVEL 5 AREA C - TELECOMMUNICATIONS FLOOR PLAN - DEMOLITION1
TELECOMMUNICATIONS KEYNOTES
1 EXISTING DATA FOR BUILDING AUTOMATION SYSTEM TO REMAIN.
2 EXISTING TELECOMMUNICATIONS EQUIPMENT IN CLOSET 5-1A TO REMAIN.
3 NEW TELECOMMUNICATIONS ROOM.
4 EXISTING TELECOMMUNICATIONS EQUIPMENT IN CLOSET 5-2A TO REMAIN.
KEY PLAN
N
22J
TT54
TT51
TT49
TT46
TT47
TT48
TT53
TT52
TT50
TT87
TT55
L A
N C
A S
T E
R R
O A
D
ANN ARBOR AVENUE
PENTHOUSE(TE)
7A-01A
OVERALL PLAN LEGEND
DESCRIPTIONSYMBOL
EXISTING TELECOMMUNICATIONS ROOM/CLOSET TO REMAIN.
NO SPACE WORK REQUIRED.
NEW TELECOMMUNICATIONS ROOM/TE.
EXISTING ROOM TO BE MODIFIED IN PLACE. REFER TO
ARCHITECTURAL FOR EXTENT OF SPACE WORK.
A. DRAWING IS DIAGRAMMATIC IN NATURE AND IS NOT TO BE CONSTRUED
AS ALL INCLUSIVE; FIELD VERIFY EXISTING CONDITIONS AND ADJUST
WORK AS REQUIRED TO EXECUTE SPECIFIED WORK.
B. EXISTING CONDITIONS INDICATED ARE BASED ON GENERAL FIELD
NOTES AND HISTORICAL DATA AND DOCUMENTATION AND ARE FOR
REFERENCE PURPOSES ONLY TO DEFINE SCOPE OF WORK; FIELD
VERIFY ALL CONDITIONS. WHERE CONDITIONS DEVIATE FROM CONTRACT
DOCUMENTS, CONTRACTOR SHALL CORDINATE WITH COR AND EOR.
C. THIS SITE IS AN ACTIVE WORKING ENVIRONMENT; SYSTEMS SHALL NOT
BE SHUTDOWN WITHOUT WRITTEN AUTHORIZATION AND COORDINATION
WITH CAMPUS OPERATIONS AS DIRECTED BY VA; ALL REQUESTS SHALL
BE SUBMITTED IN WRITING A MINIMUM OF TWENTY (20) WORKING-DAYS
PRIOR TO PROPOSED ACTIVITY DATE OR NEED UNLESS DIRECTED
OTHERWISE.
D. SEE T-001 TELECOMMUNICATIONS COVER SHEET FOR SYMBOLS
DEFINITION:
1. SYMBOLS GRAYED/ HALFTONE: INDICATED FOR REFERENCE AND/OR
INDICATING EXISTING UNLESS SPECIFICALLY NOTED OTHERWISE.
2. SYMBOLS DASHED OR SPECIFICALLY KEYED NOTED: INDICATES
DEMOLITION WORK.
E. OWNER SHALL HAVE FIRST SALVAGE RIGHTS FOR ANY DEMOLISHED
DEVICES OR MATERIAL.
F. ALL PATHWAYS ARE EXISTING UNLESS NOTED OTHERWISE.
G. REMOVE EXISTING FACEPLATE FROM WORK AREA OUTLET. REMOVE
EXISTING CABLING BACK TO SOURCE LEAVING EXISTING PATHWAY AND
BACKBOX IN PLACE FOR REUSE UNLESS NOTED OTHERWISE.
H. DEMOLISH EXISTING SPLINE TYPE CABLE TRAY TO BE EXCEPT WHERE IT
IS DETERMINED THAT THE EXISTING IS TO BE REUESED UNLESS NOTED
OTHERWISE.
TELECOMMUNICATIONS DEMOLITION GENERAL NOTES
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
DRAWING TITLE PROJECT TITLE
LOCATION
DATE CHECKED DRAWN
PROJECT NUMBERCONSULTANTS:
DRAWING #
VA HEALTH CARE SYSTEM APPROVAL:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. BR 2171 EXP. 09/30/2025
ENGR REG. NO. F-17591 EXP. 02/28/2025
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TELECOM
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
RATED ENGINEERING
609 S. KELLY AVENUE, SUITE H2
EDMOND, OK 73003
(405) 856-2965
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
STRUCTURAL ENGINEER
STAND STRUCTURAL ENGINEERING
8234 ROBINSON STREET
OVERLAND PARK, KS 66204
(913) 214-2169
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
DRAWING NUMBER
BUILDING NUMBER
/1
/2
:1
:3
BUILDING 2J - LEVEL 6 -
TELECOMMUNICATIONS FLOOR PLANS -
DEMOLITION
MDT 346 OF 478KGH
FINAL BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES DALLAS, TX
03/17/2025
549-21-700
DALLAS VA MEDICAL CENTER
4500 S LANCASTER RD
DALLAS, TX 75216
TND128
SPUR #: 2302
TELECOMMUNICATIONS KEYNOTES
1 NEW TELECOMMUNICATIONS ENCLOSURE.
N
1/16" = 1'-0"
B2J - LEVEL 6 - TELECOMMUNICATIONS FLOOR PLAN - DEMOLITION1
U P
D N
U P
D N
D N
D N
UP
FEC
MECHANICAL SHOP
CRAWL SPACE
CONTROL SHOP
1V +48"
2D/1V
1V +48" 2D/1V
5D/1V
5D/1V
5D/1V
2D/1V 3D 2D/1V 3D
5D/1V
2D/1V
3D
5D/1V
2D2D
2D
3D
2D
2D
2D
2D 2D
2D
2D
2D
5D/1V
5D/1V
2D4D2D5D/1V
2D/1V
4D/2V
4D/2V
2D/1V 2D/1V 2D/1V
4D/2V
2D/1V4D/2V
WORKROOM
WORKROOM
OFFICE
102A
2D/1V 2D/1V
2D 2D
2D
2D 2D
2D
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
1V 1V 1V
1V
1V
1V
1V
1V 1V
2D/1V
2D/2V
2D 2D
2D
2D
2D 2D
2D
2D
2D 2D
2D 2D
2D
2D2D2D
2D/1V
1V
1V
2D/1V
2D/4V
2D/1V
1V
1V 2D/1V
2D/1V
2D/1V
1V
2D/1V
1V
1V
2D/1V 2D/1V 1V
1V
2D/1V 2V
2D/1V 1V
2D/1V 1V
2D/1V
2D/1V
EX. COMM
19 SF
2D/1V 2D/1V
2D/1V
2D/1V2D/1V
2D
2D
2D
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
RESEARCH LAB
COMMON
RESOURCE
INSTRUMENTATION
ROOM
INFECTIOUS
DISEASES
RESEARCH LAB
CORRIDOR
ENGINEERING
SURGICAL LAB
038 STORAGE
STORAGE
PSYCHIATRY
RESEARCH LAB
SURGICAL
RESEARCH
SURGICAL
RESEARCH
OFFICE
SURGICAL
RESEARCH
OFFICE
022A
CORRIDOR
OFFICE
OFFICE
039D
ENGINEERING
OFFICE
039C
OFFICE
039B
OFFICE
039A
ENG. RM
RECEPTION
LAB
CORRIDOR
OFFICE
OFFICE
SURGICAL
RESEARCH
OFFICE
CORRIDOR
CORRIDOR
SURGICAL
RESEARCH
CORRIDOR
STORAGE
TOILET
HAC
BETA COUNTER
LAB
INSTRUMENTATION
ENG.
ENG.
AUTOCLAVE
GLASSWARE
CLEANING, ICE
MACHINES
CORRIDOR
RADIO IODINATION
LABRATORY
OFFICE
ENG.
CORRIDOR
STAIRS
DARK RM.
OFFICE
OFFICE
004 VEST.
OFFICE
OFFICE
009A
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
2D 2D
2D/1V
4D/2V
4D/2V
4D/2V
1V
2D/1V
2D/1V
3D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
1V 1V
WAP
1V
1V
2D/2V
1V
1V
2D/3V
WAP
WAP
WAP
1V
1V
WAP
1V2D/1V
2D/1V
WAP
TR
112 SF
PSYCHOLOGY
PSYCHIATRY
RESEARCH LAB
LAB
106A
OFFICE
106B
OFFICE
BIOCHEMISTRY
RESEARCH
BIOCHEMISTRY
RESEARCH
CORRIDOR
OFFICE
COMMON LAB
XEROX
CORRIDOR
ENG.
CORRIDOR
STAIRS
#1
INSTRUMENTATION
LAB
CONFERENCE RM.
CHEMICAL
STORAGE
SCIENTIST
OFFICE
115A
RESEARCH
NUTRITIONAL LAB
NUTRITIONAL
RESEARCH LAB
NUTRITIONAL
RESEARCH LAB
CORRIDOR
ENGINEERING RM.
CORRIDOR
HAC
TOILET
123124
CORRIDOR
WAP
WAP
WAP
WAP
WAP
KEY PLAN
N
22J
TT54
TT51
TT49
TT46
TT47
TT48
TT55
L A
N C
A S
T E
R R
O A
D
ANN ARBOR AVENUE
TT53
TT52
TT50
OVERALL PLAN LEGEND
DESCRIPTIONSYMBOL
EXISTING TELECOMMUNICATIONS ROOM/CLOSET TO REMAIN.
NO SPACE WORK REQUIRED.
NEW TELECOMMUNICATIONS ROOM/TE.
EXISTING ROOM TO BE MODIFIED IN PLACE. REFER TO
ARCHITECTURAL FOR EXTENT OF SPACE WORK.
A. DRAWING IS DIAGRAMMATIC IN NATURE AND IS NOT TO BE CONSTRUED
AS ALL INCLUSIVE; FIELD VERIFY EXISTING CONDITIONS AND ADJUST
WORK AS REQUIRED TO EXECUTE SPECIFIED WORK.
B. EXISTING CONDITIONS INDICATED ARE BASED ON GENERAL FIELD
NOTES AND HISTORICAL DATA AND DOCUMENTATION AND ARE FOR
REFERENCE PURPOSES ONLY TO DEFINE SCOPE OF WORK; FIELD
VERIFY ALL CONDITIONS. WHERE CONDITIONS DEVIATE FROM CONTRACT
DOCUMENTS, CONTRACTOR SHALL CORDINATE WITH COR AND EOR.
C. THIS SITE IS AN ACTIVE WORKING ENVIRONMENT; SYSTEMS SHALL NOT
BE SHUTDOWN WITHOUT WRITTEN AUTHORIZATION AND COORDINATION
WITH CAMPUS OPERATIONS AS DIRECTED BY VA; ALL REQUESTS SHALL
BE SUBMITTED IN WRITING A MINIMUM OF TWENTY (20) WORKING-DAYS
PRIOR TO PROPOSED ACTIVITY DATE OR NEED UNLESS DIRECTED
OTHERWISE.
D. SEE T-001 TELECOMMUNICATIONS COVER SHEET FOR SYMBOLS
DEFINITION:
1. SYMBOLS GRAYED/ HALFTONE: INDICATED FOR REFERENCE AND/OR
INDICATING EXISTING UNLESS SPECIFICALLY NOTED OTHERWISE.
2. SYMBOLS DASHED OR SPECIFICALLY KEYED NOTED: INDICATES
DEMOLITION WORK.
E. OWNER SHALL HAVE FIRST SALVAGE RIGHTS FOR ANY DEMOLISHED
DEVICES OR MATERIAL.
F. ALL PATHWAYS ARE EXISTING UNLESS NOTED OTHERWISE.
G. REMOVE EXISTING FACEPLATE FROM WORK AREA OUTLET. REMOVE
EXISTING CABLING BACK TO SOURCE LEAVING EXISTING PATHWAY AND
BACKBOX IN PLACE FOR REUSE UNLESS NOTED OTHERWISE.
H. DEMOLISH EXISTING SPLINE TYPE CABLE TRAY TO BE EXCEPT WHERE IT
IS DETERMINED THAT THE EXISTING IS TO BE REUESED UNLESS NOTED
OTHERWISE.
TELECOMMUNICATIONS DEMOLITION GENERAL NOTES
N
1/16" = 1'-0"
B3 - BASEMENT - TELECOMMUNICATIONS FLOOR PLAN - DEMOLITION1
N
1/16" = 1'-0"
B3 - LEVEL 1 - TELECOMMUNICATIONS FLOOR PLAN - DEMOLITION2
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
DRAWING TITLE PROJECT TITLE
LOCATION
DATE CHECKED DRAWN
PROJECT NUMBERCONSULTANTS:
DRAWING #
VA HEALTH CARE SYSTEM APPROVAL:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. BR 2171 EXP. 09/30/2025
ENGR REG. NO. F-17591 EXP. 02/28/2025
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TELECOM
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
RATED ENGINEERING
609 S. KELLY AVENUE, SUITE H2
EDMOND, OK 73003
(405) 856-2965
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
STRUCTURAL ENGINEER
STAND STRUCTURAL ENGINEERING
8234 ROBINSON STREET
OVERLAND PARK, KS 66204
(913) 214-2169
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
DRAWING NUMBER
BUILDING NUMBER
/1
/2
:1
:4
B3 AND B4 - TELECOMMUNICATIONS
FLOOR PLANS - DEMOLITION
MDT 347 OF 478KGH
FINAL BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES DALLAS, TX
03/17/2025
549-21-700
DALLAS VA MEDICAL CENTER
4500 S LANCASTER RD
DALLAS, TX 75216
TND129
SPUR #: 2302
N 1" = 200'-0"
B4 - BASEMENT LEVEL - TELECOMMUNICATIONS PLAN - DEMOLITION3 N
1" = 200'-0"
B4 - LEVEL 1 - TELECOMMUNICATIONS FLOOR PLAN - DEMOLITION4
TELECOMMUNICATIONS KEYNOTES
1 EXISTING WORK AREA OUTLETS MOUNTED WITHIN SYSTEMS FURNITURE TO
REMAIN. COORDINATE MOUNTING AND PATHWAY ROUTING WITH FURNITURE
AND EQUIPMENT PLANS.
2 NEW TELECOMMUNICATIONS ROOM.
3 EXISTING TELECOMMUNICATIONS EQUIPMENT IN CLOSET 19 TO REMAIN.
K-3423W
ELLW
O
RTH
TO
ILETS
VITREO
US CHINA
UPUP
UP
DN.
STAIRS
1TV
WAP
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
WAP
WAP
EX. COMM
B1A
35 SF
HAC
B1D
TOILET
B1C
MECH RM
B1E
WORK AREA
B1
E L
E C
. C L
O S
E T
B 1B
2D/1V
2D/1V 2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
1TV 2D/1V
2D/1V
OFFICE (TE)
187 SF
BREAK ROOM
HAC
CORRIDOR
CONFERENCE
ROOM
OFFICE
101A
OFFICE
101B
TOILET, UNISEX
B1E
WAP
WAP
WAP
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V2D/1V2D/1V
2D/1V
EX. COMM
B4
38 SF
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
ELECTRICAL RM
B3B
WORKROOM
B3
MECH RM
B3A
WORKROOM
B3C
STORAGE
B2
OFFICE
B5
HAC
B6
STORAGE
B6
CLOSET, ENG
B8
THERAPY ROOM
B8
TOILET/SHOWER
B10
ELEVATOR LOBBY
MECH RM
B1
WAP
WAP
WAP
TE
102B
65 SF
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
STORAGE (TE)
106A
70 SF
2D/1V
2D/1V2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
1V +48"
2D/1V2D/1V 2D/1V
2D/1V2D/1V2D/1V
OFFICE
OFFICE
WORKROOM
COMM CLOSET
102B
KITCHEN
102C
STAIRWELL
FOYER
ENTRANCE
HAC
TOILET, MALE
ELECT
THERAPY RM
THERAPY RM
OFFICE
TOILET, WOMEN
CUBICLE AREA
STORAGE
110A
OFFICE
OFFICE
STORAGE
109A
VESTIBULE
ELEVATOR LOBBY
WAP WAP WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
WORKROOM
OFFICE
CLOSET
201A
CLOSET
221A
OFFICE
TOILET, UNISEX
219A
STORAGE
219B
STORAGE
CLOSET
203A
COMMUNICATION
CLOSET
217A
ELEVATOR LOBBY
TOILET, MALE
STORAGE
TREATMENT ROOM
OFFICE
TOILET, FEMALE
OFFICE
ELECT
OFFICE
CLOSET
213A
OFFICE
OFFICE
WAP
WAP
WAP
WAP
WAP
WAP
WAPWAP
WAP
WAP
WAP
KEY PLAN
N
22J
TT54
TT51
TT49
TT46
TT47
TT48
TT53
TT52
TT50
TT87
TT55
L A
N C
A S
T E
R R
O A
D
ANN ARBOR AVENUE
TR
098A
109 SF
2D/1V2D/1V
STORAGE
STORAGE
CRAWL SPACE
FOYER
CRAWL SPACE
WAP
5D 5D 5D 5D
5D 5D 5D
2D/1V
2D/1V
2D/1V
1V
2D/1V
2D/1V
2D/1V
WAP
1D/1V
1V
2D
2D
2D/1V
2D 2D
2D
2D/1V
2D/1V
6D +36"
WAP
5D
2D
2D +36"
2D 2D 2D
2D
2D
BREAKROOM
WOMEN
ELECT.
OFFICE
TELE.
EMS
OFFICE
101A
RECEPTION
WAITING
CLASSROOM
TOILET
WAP
WAP
WAP
2D/1V
2D/1V
2D/1V 2D/1V 2D/1V 2D/1V 2D/1V 2D/1V2D/1V 2D/1V 2D/1V 2D/1V
2D/1V2D/1V2D/1V2D/1V2D/1V2D/1V2D/1V 2D/1V2D/1V2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
1D/1V
1V 1V
3D/1V
WAPWAP
2D/1V
2D/1V
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
MEN
210HEALTH NET
OFFICE
OFFICE
OFFICE
C O
R R
ID
O
R
OFFICE
CORRIDOR
TOILET
OFFICE
OFFICE
OFFICE
OFFICE
STORAGE
WAP
WAP
WAP
WAP
WAP
OVERALL PLAN LEGEND
DESCRIPTIONSYMBOL
EXISTING TELECOMMUNICATIONS ROOM/CLOSET TO REMAIN.
NO SPACE WORK REQUIRED.
NEW TELECOMMUNICATIONS ROOM/TE.
EXISTING ROOM TO BE MODIFIED IN PLACE. REFER TO
ARCHITECTURAL FOR EXTENT OF SPACE WORK.
A. DRAWING IS DIAGRAMMATIC IN NATURE AND IS NOT TO BE CONSTRUED
AS ALL INCLUSIVE; FIELD VERIFY EXISTING CONDITIONS AND ADJUST
WORK AS REQUIRED TO EXECUTE SPECIFIED WORK.
B. EXISTING CONDITIONS INDICATED ARE BASED ON GENERAL FIELD
NOTES AND HISTORICAL DATA AND DOCUMENTATION AND ARE FOR
REFERENCE PURPOSES ONLY TO DEFINE SCOPE OF WORK; FIELD
VERIFY ALL CONDITIONS. WHERE CONDITIONS DEVIATE FROM CONTRACT
DOCUMENTS, CONTRACTOR SHALL CORDINATE WITH COR AND EOR.
C. THIS SITE IS AN ACTIVE WORKING ENVIRONMENT; SYSTEMS SHALL NOT
BE SHUTDOWN WITHOUT WRITTEN AUTHORIZATION AND COORDINATION
WITH CAMPUS OPERATIONS AS DIRECTED BY VA; ALL REQUESTS SHALL
BE SUBMITTED IN WRITING A MINIMUM OF TWENTY (20) WORKING-DAYS
PRIOR TO PROPOSED ACTIVITY DATE OR NEED UNLESS DIRECTED
OTHERWISE.
D. SEE T-001 TELECOMMUNICATIONS COVER SHEET FOR SYMBOLS
DEFINITION:
1. SYMBOLS GRAYED/ HALFTONE: INDICATED FOR REFERENCE AND/OR
INDICATING EXISTING UNLESS SPECIFICALLY NOTED OTHERWISE.
2. SYMBOLS DASHED OR SPECIFICALLY KEYED NOTED: INDICATES
DEMOLITION WORK.
E. OWNER SHALL HAVE FIRST SALVAGE RIGHTS FOR ANY DEMOLISHED
DEVICES OR MATERIAL.
F. ALL PATHWAYS ARE EXISTING UNLESS NOTED OTHERWISE.
G. REMOVE EXISTING FACEPLATE FROM WORK AREA OUTLET. REMOVE
EXISTING CABLING BACK TO SOURCE LEAVING EXISTING PATHWAY AND
BACKBOX IN PLACE FOR REUSE UNLESS NOTED OTHERWISE.
H. DEMOLISH EXISTING SPLINE TYPE CABLE TRAY TO BE EXCEPT WHERE IT
IS DETERMINED THAT THE EXISTING IS TO BE REUESED UNLESS NOTED
OTHERWISE.
TELECOMMUNICATIONS DEMOLITION GENERAL NOTES
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
DRAWING TITLE PROJECT TITLE
LOCATION
DATE CHECKED DRAWN
PROJECT NUMBERCONSULTANTS:
DRAWING #
VA HEALTH CARE SYSTEM APPROVAL:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. BR 2171 EXP. 09/30/2025
ENGR REG. NO. F-17591 EXP. 02/28/2025
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TELECOM
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
RATED ENGINEERING
609 S. KELLY AVENUE, SUITE H2
EDMOND, OK 73003
(405) 856-2965
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
STRUCTURAL ENGINEER
STAND STRUCTURAL ENGINEERING
8234 ROBINSON STREET
OVERLAND PARK, KS 66204
(913) 214-2169
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
DRAWING NUMBER
BUILDING NUMBER
/1
/2
:1
:5
B5, B6, AND B7 - TELECOMMUNICATIONS
FLOOR PLANS - DEMOLITION
MDT 348 OF 478KGH
FINAL BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES DALLAS, TX
03/17/2025
549-21-700
DALLAS VA MEDICAL CENTER
4500 S LANCASTER RD
DALLAS, TX 75216
TND130
SPUR #: 2302
N
1/16" = 1'-0"
B5 - BASEMENT - TELECOMMUNICATIONS FLOOR PLAN - DEMOLITION1
N
1/16" = 1'-0"
B5 - LEVEL 1 - TELECOMMUNICATIONS FLOOR PLAN - DEMOLITION2
N
1/16" = 1'-0"
B6 - BASEMENT - TELECOMMUNICATIONS FLOOR PLAN - DEMOLITION3
N
1/16" = 1'-0"
B6 - LEVEL 1 - TELECOMMUNICATIONS FLOOR PLAN - DEMOLITION4
N
1/16" = 1'-0"
B6 - LEVEL 2 - TELECOMMUNICATIONS FLOOR PLAN - DEMOLITION5
N
1/16" = 1'-0"
B7 - BASEMENT - TELECOMMUNICATIONS FLOOR PLAN - DEMOLITION6
N
1/16" = 1'-0"
B7 - LEVEL 1 - TELECOMMUNICATIONS FLOOR PLAN - DEMOLITION7
N
1/16" = 1'-0"
B7 - LEVEL 2 - TELECOMMUNICATIONS FLOOR PLAN - DEMOLITION8
TELECOMMUNICATIONS KEYNOTES
1 EXISTING TELECOMMUNICATIONS EQUIPMENT IN COMMUNICATION CLOSET 217A
TO REMAIN.
2 NEW TELECOMMUNICATIONS ENCLOSURE.
3 EXISTING TELECOMMUNICATIONS ROOM TO REMAIN AND EXPAND.
4 EXISTING TELECOMMUNICATIONS EQUIPMENT IN CLOSET B1A TO REMAIN.
5 EXISTING TELECOMMUNICATIONS EQUIPMENT IN TELE. 106 TO REMAIN.
6 EXISTING TELECOMMUNICATIONS EQUIPMENT IN CLOSET B4 TO REMAIN.
7 EXISTING TELECOMMUNICATIONS EQUIPMENT IN STORAGE (TE) 106A TO
REMAIN.
1D/1V 1D/1V
1D/1V
1D/1V 1D/1V2D/1V
2D/1V
WAP
WAP
2D/1V ARCHIVE STORAGE
B105
CONFERENCE RM
B103
BREAK RM
B100
TOILET
B104
HKC
B102
TOILET
B101
MECH RM
B106
PHONE CL
B108
CLOSET
B100A
2D/1V
2D/1V2D/1V
2D/1V 2D/1V
2D/1V2D/1V2D/1V2D/1V2D/1V2D/1V
2D/1V
2D/1V
2D/1V 2D/1V 2D/1V 2D/1V 2D/1V 2D/1V
2D/1V 2D/1V
4D/2V 4D/2V
1V
1V
1V
1V 2D/1V
COPY ROOM
75 SF
POLICE (TE)
102 SF
OFFICE
A123
OFFICE
OFFICE
OFFICE
OFFICE
CONFERENCE
OFFICE
OFFICE
HALL
ENTRY
100A
OFFICE AREA
OFFICE
OFFICE
DEPT. HALL
OFFICE
121E
OFFICE
121D
OFFICE
121C
OFFICE
121B
OFFICE
121A
OFFICE
OFFICE
121I
OFFICE
121G
OFFICE
121F
OFFICE
OFFICE
OFFICE
MALE TOILET
FEMALE TOILET
WAP
WAP
WAP
WAP
WAP
WAP
WAP
2D 2D/1V 2D/1V 2D/1V
1TV
2D/1V 2D/1V 2D/1V 2D/1V 2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V2D/1V2D/1V 2D/1V
1D
2D/1V
WAP
WAP
WAP
WAP
OFFICE
TOILET
TOILET
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
WORK RM
OFFICE
OFFICE
203A
TV
KEY PLAN
N
22J
TT54
TT51
TT49
TT46
TT47
TT48
TT53
TT52
TT50
TT87
TT55
L A
N C
A S
T E
R R
O A
D
ANN ARBOR AVENUE
WAP
TV
WAP
1D/1V
1D
1D
1D
1D
1D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
1D
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V2D/1V
2D/1V
2D/1V
4D/2V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/2V
4D/1V
2D/1V
4D/2V
1V
1V 1V
1V
1V
1V1V
2D/1V
OFFICE (TE)
258 SF
WAP
WAP
WAP WAP
WAP
WAP
WAP
WAP
2D/1V 2D/1V 2D/1V
WAP
2D/1V
2D/1V
WAP
WAP
WAP
2D/1V
2D/1V
OFFICE
OFFICE
OFFICE
MTG
HAC
RESTROOM
OFFICE
OFFICE
OFFICE
RESTROOM
PRINTER/ COPIERS
RESTROOM
OFFICE
TOILET
CORR.
2D/1V
WAP
WAP
WAP
OFFICE
130C
OFFICE
130D
OFFICE
130E
OFFICE
130F
OFFICE
130B
OFFICE
130A
OFFICE
OFFICE
119A
CAD ROOM
OFFICE
OFFICE
ADMIN
WORK STATION
ACCOUNTING
OFFICE
OFFICE
OFFICE
EX. COMM
10 SF
MECHANIC SHOP
Not Enclosed
2D/1V
2D/1V
2D/1V
WAP
WAP
OFFICE (TE)
700A
192 SF
1TV
1TV
CARPENTER SHOP
STORAGE
800AA
TOILET
900A
OFFICE
800A
BREAK ROOM
WELDING SHOP
600A
L O
C K
E R
R O
O M
STORAGE
800B
PLUMBING SHOP
WAP
WAP
EX. COMM
600B
35 SF
2D/1V 2D/1V
1D/1V 2D/1V
1D
1D/1V
1V
WAP
WAP
2D/1V
2D/1V
1D/1TV
1TV 1D
TVWAP
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
STORAGE
100B
OFFICE
OFFICE
100A
SERVICE BAY
100C
ELECTRIC
300BAA
STORAGE
100BBA
STORAGE
100BB
TOILET
100BA
STORAGE
300BA
OFFICE
300A
STORAGE
300B
STORAGE
300BB
ELECTRIC SHOP
PAINT SHOP
STORAGE
300C
MOTOR POOL
STORAGE
WAP
WAP
OVERALL PLAN LEGEND
DESCRIPTIONSYMBOL
EXISTING TELECOMMUNICATIONS ROOM/CLOSET TO REMAIN.
NO SPACE WORK REQUIRED.
NEW TELECOMMUNICATIONS ROOM/TE.
EXISTING ROOM TO BE MODIFIED IN PLACE. REFER TO
ARCHITECTURAL FOR EXTENT OF SPACE WORK.
A. DRAWING IS DIAGRAMMATIC IN NATURE AND IS NOT TO BE CONSTRUED
AS ALL INCLUSIVE; FIELD VERIFY EXISTING CONDITIONS AND ADJUST
WORK AS REQUIRED TO EXECUTE SPECIFIED WORK.
B. EXISTING CONDITIONS INDICATED ARE BASED ON GENERAL FIELD
NOTES AND HISTORICAL DATA AND DOCUMENTATION AND ARE FOR
REFERENCE PURPOSES ONLY TO DEFINE SCOPE OF WORK; FIELD
VERIFY ALL CONDITIONS. WHERE CONDITIONS DEVIATE FROM CONTRACT
DOCUMENTS, CONTRACTOR SHALL CORDINATE WITH COR AND EOR.
C. THIS SITE IS AN ACTIVE WORKING ENVIRONMENT; SYSTEMS SHALL NOT
BE SHUTDOWN WITHOUT WRITTEN AUTHORIZATION AND COORDINATION
WITH CAMPUS OPERATIONS AS DIRECTED BY VA; ALL REQUESTS SHALL
BE SUBMITTED IN WRITING A MINIMUM OF TWENTY (20) WORKING-DAYS
PRIOR TO PROPOSED ACTIVITY DATE OR NEED UNLESS DIRECTED
OTHERWISE.
D. SEE T-001 TELECOMMUNICATIONS COVER SHEET FOR SYMBOLS
DEFINITION:
1. SYMBOLS GRAYED/ HALFTONE: INDICATED FOR REFERENCE AND/OR
INDICATING EXISTING UNLESS SPECIFICALLY NOTED OTHERWISE.
2. SYMBOLS DASHED OR SPECIFICALLY KEYED NOTED: INDICATES
DEMOLITION WORK.
E. OWNER SHALL HAVE FIRST SALVAGE RIGHTS FOR ANY DEMOLISHED
DEVICES OR MATERIAL.
F. ALL PATHWAYS ARE EXISTING UNLESS NOTED OTHERWISE.
G. REMOVE EXISTING FACEPLATE FROM WORK AREA OUTLET. REMOVE
EXISTING CABLING BACK TO SOURCE LEAVING EXISTING PATHWAY AND
BACKBOX IN PLACE FOR REUSE UNLESS NOTED OTHERWISE.
H. DEMOLISH EXISTING SPLINE TYPE CABLE TRAY TO BE EXCEPT WHERE IT
IS DETERMINED THAT THE EXISTING IS TO BE REUESED UNLESS NOTED
OTHERWISE.
TELECOMMUNICATIONS DEMOLITION GENERAL NOTES
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
DRAWING TITLE PROJECT TITLE
LOCATION
DATE CHECKED DRAWN
PROJECT NUMBERCONSULTANTS:
DRAWING #
VA HEALTH CARE SYSTEM APPROVAL:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. BR 2171 EXP. 09/30/2025
ENGR REG. NO. F-17591 EXP. 02/28/2025
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TELECOM
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
RATED ENGINEERING
609 S. KELLY AVENUE, SUITE H2
EDMOND, OK 73003
(405) 856-2965
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
STRUCTURAL ENGINEER
STAND STRUCTURAL ENGINEERING
8234 ROBINSON STREET
OVERLAND PARK, KS 66204
(913)…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .