This is a construction bid drawing document (Volume 2) for the EHRM Infrastructure Upgrades project at Dallas VA Medical Center. The document contains demolition and floor plans, door schedules, finish specifications, and technical details for multiple buildings undergoing renovation and expansion work.
The project involves telecommunications room (TR) construction and infrastructure upgrades across numerous buildings at the Dallas VA Medical Center (Building 1, Building 2, Building 2J, Building 3, and multiple numbered buildings including 5, 6, 8, 9, 11, 13, 43, 45, 60, 68, 69, 71, 72, 74, 75, 77, 80, 81, 82, and temporary buildings TT46-TT55). The work includes demolition of existing walls, ceilings, and fixtures; installation of new fire-rated partitions and doors with dual authentication (PIV and PIN code) access control systems; reconfiguration of mechanical systems and sprinkler systems; and installation of fire-rated plywood protection on walls. Specifications require negative pressure HEPA filtration during demolition, fire caulking of all penetrations, and protective barriers in non-demolition areas. New doors feature hollow metal frames with painted finishes and are sized between 2'-0" to 6'-0" wide and 7'-0" to 8'-0" tall, with fire ratings ranging from 20 minutes to 90 minutes. Flooring finishes include static dissipative tile (SD1) with rubber base (RB1) in TR spaces and existing tile replacement (ETR) in other areas, with fire-retardant plywood wall protection on walls. The drawing date is March 17, 2025, prepared by Spur Design, LLC (Architect) with supporting consultants including Olsson (Civil Engineer), Rated Engineering (Fire Protection), and other specialists. The document is marked as preliminary and not for construction purposes.
View the file
Other files
Show all 36
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GENERAL DEMOLITION PLAN NOTES
1. ALL EXISTING WALL DIMENSIONS ARE TO FINISH FACE, UNLESS OTHERWISE NOTED
2. THE CONTRACTOR SHALL VERIFY DIMENSIONS OF EXISTING CONDITIONS, AND NOTIFY THE
ARCHITECT IN WRITING OF ANY DISCREPANCIES. ALL INFORMATION SHOWN ON THE
CONSTRUCTION DOCUMENTS IS BASED ON FIELD OBSERVATIONS AND/OR THE ORIGINAL
CONSTRUCTION DOCUMENTS OF THE FACILITY.
3. DEMOLITION AND CONSTRUCTION WORK MUST BE DONE UNDER NEGATIVE PRESSURE UTILIZING
HEPA FILTRATION UNITS. SEE INFECTION CONTROL NOTES AND SPECIFICATIONS.
4. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT OR AREA HAS BEEN
INSPECTED BY THE SAFETY OFFICER AND INFECTION CONTROL COORDINATOR AND
THOROUGHLY CLEANED BY ENVIRONMENTAL MANAGEMENT SERVICES.
5. THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING FOR EXISTING FLOOR, WALL AND
CEILING FINISHES IN EXISTING AREAS NOT DESIGNATED FOR DEMOLITION OR NEW
CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE
CAUSED BY THIER WORK OR ANY SUBCONTRACTOR.
6. THE CONTRACTOR SHALL VERIFY THAT NEW MECHANICAL SYSTEMS CAN BE INSTALLED IN
EXISTING SPACES TO CLEAR EXISTING CEILING AND OTHER CONSTRUCTED ITEMS AND MAINTAIN
FLOOR TO CEILING HEIGHTS INDICATED ON DRAWINGS. IF DISCREPANCIES OCCUR DUE TO
EXISTING CONDITIONS, CONSULT WITH THE ARCHITECT BEFORE PROCEEDING.
7. THE FINISH FACE OF MATERIAL OF NEW PARTITIONS SHALL ALIGN ON BOTH SIDES OF THE PARTITION WITH THE FACE OF THE MATERIALS ON EXISTING COLUMNS, WALLS, OR PARTITIONS, UNLESS NOTED OTHERWISE.
8. NO WORK TO BE DONE IN AREAS HATCHED GRAY IN PLANS, HOWEVER WORK MIGHT NEED TO BE
PERFORMED IN CEILING OR EXISTING CHASES THROUGHOUT BUILDING. REFERENCE
MECHANICAL AND ELECTRICAL DRAWINGS FOR EXTENT OF WORK. COORDINATE ACCESS TO
ROOMS OUTSIDE OF SCOPE WITH OWNER.
9. ALL EXISTING TELECOM EQUIPMENT TO REMAIN UNLESS NOTED OTHERWISE. REFER TO TELECOM
DRAWINGS.
GENERAL PLAN NOTES
1. ALL NEW DOOR FRAMES TO BE LOCATED 4" FROM OUTSIDE OF FRAME TO FINISH FACE OF
ADJACENT WALL UNLESS NOTED OTHERWISE.
2. FIRE CAULK ALL PENETRATIONS IN EXISTING WALLS, FLOORS, OR CEILINGS.
3. ALL WALLS TO GO TO DECK. IF EXISTING WALL DOES NOT CURRENTLY GO TO DECK,
CONTRACTOR TO EXTEND WALL SYSTEM UP TO EXISTING STRUCTURE ABOVE PRIOR TO FIRE
CAULKING. MAINTAINING EXISTING FIRE RATING.
4. ALL NEW CONSTRUCTION WALLS ARE DIMENSIONED TO CENTERLINE OF METAL STUD, UNLESS
NOTED OTHERWISE.
5. ALL EXISTING WALLS ARE DIMENSIONED TO FACE OF EXISTING FINISH, UNLESS NOTED
OTHERWISE.
6. ALL EXISTING GLAZING LOCATED IN EXTERIOR WALLS WITHIN EXISTING AND NEW TELECOM
ROOMS SHALL RECEIVE 15-MINUTE FORCED INTRUSION RESISTANT FILM & CONTACT SENSORS
TIED TO THE SECURITY CONTROL CENTER.
GENERAL REFLECTED CEILING PLAN NOTES
1. CEILINGS IN ALL TR'S ARE TO BE OPEN TO BOTTOM OF DECK, UNLESS NOTED OTHERWISE.
2. ALL SURFACES OF FURRDOWNS TO BE PAINTED TO MATCH UNLESS NOTED OTHERWISE.
3. ALL FIXTURES IN DEMOLISHED CEILINGS ARE TO FIRST BE REMOVED AND RETURNED TO OWNER, UNLESS NOTED OTHERWISE.
4. RECONFIGURE SPRINKLER SYSTEM IN DEMOLISHED CEILINGS PER FIRE PROTECTION
REQUIREMENTS.
5. ALL FIXTURES TO BE CENTERD IN ROOM UNLESS NOTED OTHERWISE.
NEW DOOR & FRAME
APPLICATION.
REF: DOOR SCHEDULE
DEMOLITION & NEW FLOOR PLAN LEGEND
AREA NOT IN ARCHITECTURAL
SCOPE, REF: OTHER
DISCIPLINES
EXISTING WALL TO BE
DEMOLISHED IN ITS ENTIRETY
EXISTING PARTITION TO
REMAIN & PROTECT
EXISTING DOOR & FRAME TO
REMAIN AND PROTECT
EXISTING FRAME TO REMAIN,
REMOVE EXISTING DOOR; REF:
KEY NOTES FOR DEMO NOTES.
EXISTING 2' x 2' ACOUSTICAL
CEILING TO BE DEMOLISHED
EXISTING GYPSUM BOARD
CEILING TO BE DEMOLISHED
EXISTING 2 x 4 LIGHT FIXTURE
TO BE DEMOLISHED
REF: ELECTRICAL
DEMOLITION REFLECTED CEILING PLAN LEGEND
EXISTING 2' x 4' ACOUSTICAL
CEILING TO BE DEMOLISHED
EXISTING SUPPLY AIR
DIFFUSER TO BE DEMOLISHED
REF: MECHANICAL
EXISTING EXHAUST AIR
GRILLE TO BE DEMOLISHED
REF: MECHANICAL
EXISTING SUSPENDED LIGHT
FIXTURE TO BE REMOVED
REF: ELECTRICAL
EXISTING RETURN AIR GRILLE
TO BE DEMOLISHED
REF: MECHANICAL
EXISTING 2 x 2 LIGHT FIXTURE
TO BE DEMOLISHED
REF: ELECTRICAL
EXISTING GYPSUM BOARD
CEILING TO REMAIN
2' x 2' ACOUSTICAL CEILING
2 x 2 LIGHT FIXTURE
REF: ELECTRICAL
CEILING HEIGHT, ABOVE
FINISH FLOOR
2 x 4 LIGHT FIXTURE
REF: ELECTRICAL
00'-00"
REFLECTED CEILING PLAN LEGEND
2' x 4' ACOUSTICAL CEILING
RETURN AIR GRILLE
REF: MECHANICAL
SUPPLY AIR DIFFUSER
REF: MECHANICAL
SUSPENDED LIGHT FIXTURE
REF: ELECTRICAL
DUCTLESS SPLIT INDOOR
UNIT; REF: MECHANICAL
EXHAUST AIR GRILLE
REF: MECHANICAL
HAC
'-4
10'-0"
EX. COMM.
122+
1' -4
F
V
+/- 10'-0" FV
2.96
2.67
2.190
113 SF
TE
HAC
10.31
26.13
6.09
27.06
122-TT54
+/- 10'-0" FV
1'
-4
F V
228 SF
RECEPTION
+/- 21'-8 1/2" FV
0'
-0
F V
10.31
228 SF
RECEPTION
+/- 21'-8 1/2" FV
0'
-0
F V
6.09
27.06
26.13
GROUP C ROOM
4'
-1 0"
F V
+/- 13'-4 1/2" FV
2.96
332 SF
GROUP C
ROOM (TE)
10.31
4'
-1 0"
F V
+/- 13'-4 1/2" FV
27.06
6.09
0-
TT53
26.13
EX. COMM
'-3
/2
F
V
+/- 7'-1" FV
2.190
2.105
OFFICE
1052.73
2.180
EX. COMM
'-3
/2
F
V
+/- 7'-1" FV
OFFICE
10.30
6.09
26.13
27.06
6.091' -1
1'
-7
/2
4' -6
3'-2" 5" 3'-4"
3/ 4"
3/ 4"
8'-6"+/- 8'-6" FV
20 SF
EX. TELECOM
'-1
1" F
V
'-0
F V
+/- 3'-11" FV
2.73
OFFICE
2.96
+/- 8'-6" FV
20 SF
EX. TELECOM
OFFICE (TE)
'-1
1" F
V
'-0
F V
+/- 3'-11" FV
6.09
10.31
27.06
6-
TT50
5' -6
10'-11"
'-6
F
V
+/- 10'-11" FV
EX. COMM
104-A
2.190
2.105
2.105
'-6
F
V
+/- 10'-11" FV
10.31
6.0927.06
EX. COMM
104-A
116 SF
MEANS TEST
COORDINATOR
(TE)
+/- 10'-6" FV
1'
-0
F V
10.31
6.09
27.06
1-
TT49
MEANS TEST
COORDINATOR
+/- 10'-6" FV
1'
-0
F V
2.96
PARTITION LEGEND
1 HOUR FIRE RATED
2 HOUR FIRE RATED
SMOKE PARTITION/BARRIER
NEW NON-RATED WALLS
EXISTING WALL TO REMAIN
EXISTING 1 HOUR FIRE
EXISTING 2 HOUR FIRE
NOTE: NOT ALL SYMBOLS MAY BE USED
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
DRAWING TITLE PROJECT TITLE
LOCATION
DATE CHECKED DRAWN
PROJECT NUMBERCONSULTANTS:
DRAWING #
VA HEALTH CARE SYSTEM APPROVAL:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. BR 2171 EXP. 09/30/2025
ENGR REG. NO. F-17591 EXP. 02/28/2026
CIVIL ENGINEER
OLSSON
550 E. ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 890-8802
MECH / ELEC / PLUMB / TELECOM
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
RATED ENGINEERING
609 S. KELLY AVENUE, SUITE H2
EDMOND, OK 73003
(405) 210-5814
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
11140 S. TOWNE SQUARE, STE 100
ST. LOUIS, MO 63123
(314) 917-0148
STRUCTURAL ENGINEER
STAND STRUCTURAL ENGINEERING
8234 ROBINSON STREET
OVERLAND PARK, KS 66204
(913) 214-2169
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
DRAWING NUMBER
BUILDING NUMBER
/1
/2
:4 :3
P
M
BUILDINGS TT49, TT50, TT51, TT52, TT53,
TT54, AND TT55 - ENLARGED PLANS -
LEVEL 1
CAB 142 OF 478AJS
FINAL BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES DALLAS, TX
03/17/2025
549-21-700
DALLAS VA MEDICAL CENTER
4500 S LANCASTER RD
DALLAS, TX 75216
AE139
SPUR #: 2302
KEYNOTE LEGEND
2.67 EXISTING FIRE RATED PLYWOOD TO REMAIN. SEE FINISH SCHEDULE.
2.73 EXISTING TR EQUIPMENT TO REMAIN. REF: GENERAL DEMOLITION NOTE 9 & TELECOM.
2.96 REUSE EXISTING DOOR AND FRAME. REPLACE HARDWARE. REF: DOOR SCHEDULE &
HARDWARE SCHEDULE.
2.105 EXISTING ELECTRICAL EQUIPMENT TO REMAIN. REF: ELECTRICAL.
2.180 EXISTING EQUIPMENT TO REMAIN. REF: TELECOM.
2.190 DEMOLISH EXISTING TELECOM RACK. REF: TELECOM.
6.09 3/4" FIRE RATED PLYWOOD (4X8) MOUNTED 18" FROM FLOOR, PAINTED. REF: ROOM FINISH
SCHEDULE.
10.30 TELECOMMUNICATION RACK, REF: TELECOM
10.31 WALL-MOUNTED TELECOMMUNICATION CABINET, REF: TELECOM
26.13 ELECTRICAL PANEL, REF: ELECTRICAL
27.06 GROUND BAR, REF: TELECOM
TT50, TT51, TT52, TT53, TT54, AND TT55
N
1/4" = 1'-0" 10/ A-111
BLDG TT54 - LEVEL 1 - 122 - DEMO PLAN11
N
1/4" = 1'-0" 10/ A-111
BLDG TT54 - LEVEL 1 - 122 - FLOOR PLAN12
N
1/4" = 1'-0" 8/ A-111
BLDG TT52 - LEVEL 1 - 100 - DEMO PLAN5
N
1/4" = 1'-0" 8/ A-111
BLDG TT52 - LEVEL 1 - 100 - FLOOR PLAN6
N
1/4" = 1'-0" 9/ A-111
BLDG TT53 - GROUP C - DEMO PLAN9
N
1/4" = 1'-0" 9/ A-111
BLDG TT53 - GROUP C - FLOOR PLAN10
N
1/4" = 1'-0" 11/ A-111
BLDG TT55 - LEVEL 1 - 104 - DEMO PLAN13
N
1/4" = 1'-0" 11/ A-111
BLDG TT55 - LEVEL 1 - 104 - FLOOR PLAN14
N
1/4" = 1'-0" 6/ A-111
BLDG TT50 - LEVEL 1 - DEMO PLAN3
N
1/4" = 1'-0" 6/ A-111
BLDG TT50 - LEVEL 1 - FLOOR PLAN4
N
1/4" = 1'-0" 7/ A-111
BLDG TT51 - LEVEL 1 - 104-A - DEMO PLAN7
N
1/4" = 1'-0" 7/ A-111
BLDG TT51 - LEVEL 1 - 104-A - FLOOR PLAN8
N
1/4" = 1'-0" 5/ A-111
BLDG TT49 - LEVEL 1 - 111 - FLOOR PLAN2
N
1/4" = 1'-0" 5/ A-111
BLDG TT49 - LEVEL 1 - 111 - DEMO PLAN1
No. REVISION DESCRIPTION DATE
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
2. THE CONTRACTOR SHALL VERIFY DIMENSIONS OF EXISTING CONDITIONS, AND NOTIFY THE
ARCHITECT IN WRITING OF ANY DISCREPANCIES. ALL INFORMATION SHOWN ON THE
CONSTRUCTION DOCUMENTS IS BASED ON FIELD OBSERVATIONS AND/OR THE ORIGINAL
CONSTRUCTION DOCUMENTS OF THE FACILITY.
3. DEMOLITION AND CONSTRUCTION WORK MUST BE DONE UNDER NEGATIVE PRESSURE UTILIZING
HEPA FILTRATION UNITS. SEE INFECTION CONTROL NOTES AND SPECIFICATIONS.
4. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT OR AREA HAS BEEN
INSPECTED BY THE SAFETY OFFICER AND INFECTION CONTROL COORDINATOR AND
THOROUGHLY CLEANED BY ENVIRONMENTAL MANAGEMENT SERVICES.
5. THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING FOR EXISTING FLOOR, WALL AND
CEILING FINISHES IN EXISTING AREAS NOT DESIGNATED FOR DEMOLITION OR NEW
CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE
CAUSED BY THIER WORK OR ANY SUBCONTRACTOR.
6. THE CONTRACTOR SHALL VERIFY THAT NEW MECHANICAL SYSTEMS CAN BE INSTALLED IN
EXISTING SPACES TO CLEAR EXISTING CEILING AND OTHER CONSTRUCTED ITEMS AND MAINTAIN
FLOOR TO CEILING HEIGHTS INDICATED ON DRAWINGS. IF DISCREPANCIES OCCUR DUE TO
EXISTING CONDITIONS, CONSULT WITH THE ARCHITECT BEFORE PROCEEDING.
7. THE FINISH FACE OF MATERIAL OF NEW PARTITIONS SHALL ALIGN ON BOTH SIDES OF THE PARTITION WITH THE FACE OF THE MATERIALS ON EXISTING COLUMNS, WALLS, OR PARTITIONS, UNLESS NOTED OTHERWISE.
8. NO WORK TO BE DONE IN AREAS HATCHED GRAY IN PLANS, HOWEVER WORK MIGHT NEED TO BE
PERFORMED IN CEILING OR EXISTING CHASES THROUGHOUT BUILDING. REFERENCE
MECHANICAL AND ELECTRICAL DRAWINGS FOR EXTENT OF WORK. COORDINATE ACCESS TO
ROOMS OUTSIDE OF SCOPE WITH OWNER.
9. ALL EXISTING TELECOM EQUIPMENT TO REMAIN UNLESS NOTED OTHERWISE. REFER TO TELECOM
DRAWINGS.
GENERAL PLAN NOTES
1. ALL NEW DOOR FRAMES TO BE LOCATED 4" FROM OUTSIDE OF FRAME TO FINISH FACE OF
ADJACENT WALL UNLESS NOTED OTHERWISE.
2. FIRE CAULK ALL PENETRATIONS IN EXISTING WALLS, FLOORS, OR CEILINGS.
3. ALL WALLS TO GO TO DECK. IF EXISTING WALL DOES NOT CURRENTLY GO TO DECK,
CONTRACTOR TO EXTEND WALL SYSTEM UP TO EXISTING STRUCTURE ABOVE PRIOR TO FIRE
CAULKING. MAINTAINING EXISTING FIRE RATING.
4. ALL NEW CONSTRUCTION WALLS ARE DIMENSIONED TO CENTERLINE OF METAL STUD, UNLESS
NOTED OTHERWISE.
5. ALL EXISTING WALLS ARE DIMENSIONED TO FACE OF EXISTING FINISH, UNLESS NOTED
OTHERWISE.
6. ALL EXISTING GLAZING LOCATED IN EXTERIOR WALLS WITHIN EXISTING AND NEW TELECOM
ROOMS SHALL RECEIVE 15-MINUTE FORCED INTRUSION RESISTANT FILM & CONTACT SENSORS
TIED TO THE SECURITY CONTROL CENTER.
GENERAL REFLECTED CEILING PLAN NOTES
1. CEILINGS IN ALL TR'S ARE TO BE OPEN TO BOTTOM OF DECK, UNLESS NOTED OTHERWISE.
2. ALL SURFACES OF FURRDOWNS TO BE PAINTED TO MATCH UNLESS NOTED OTHERWISE.
3. ALL FIXTURES IN DEMOLISHED CEILINGS ARE TO FIRST BE REMOVED AND RETURNED TO OWNER, UNLESS NOTED OTHERWISE.
4. RECONFIGURE SPRINKLER SYSTEM IN DEMOLISHED CEILINGS PER FIRE PROTECTION
REQUIREMENTS.
5. ALL FIXTURES TO BE CENTERD IN ROOM UNLESS NOTED OTHERWISE.
NEW DOOR & FRAME
APPLICATION.
REF: DOOR SCHEDULE
DEMOLITION & NEW FLOOR PLAN LEGEND
AREA NOT IN ARCHITECTURAL
SCOPE, REF: OTHER
DISCIPLINES
EXISTING WALL TO BE
DEMOLISHED IN ITS ENTIRETY
EXISTING PARTITION TO
REMAIN & PROTECT
EXISTING DOOR & FRAME TO
REMAIN AND PROTECT
EXISTING FRAME TO REMAIN,
REMOVE EXISTING DOOR; REF:
KEY NOTES FOR DEMO NOTES.
EXISTING 2' x 2' ACOUSTICAL
CEILING TO BE DEMOLISHED
EXISTING GYPSUM BOARD
CEILING TO BE DEMOLISHED
EXISTING 2 x 4 LIGHT FIXTURE
TO BE DEMOLISHED
REF: ELECTRICAL
DEMOLITION REFLECTED CEILING PLAN LEGEND
EXISTING 2' x 4' ACOUSTICAL
CEILING TO BE DEMOLISHED
EXISTING SUPPLY AIR
DIFFUSER TO BE DEMOLISHED
REF: MECHANICAL
EXISTING EXHAUST AIR
GRILLE TO BE DEMOLISHED
REF: MECHANICAL
EXISTING SUSPENDED LIGHT
FIXTURE TO BE REMOVED
REF: ELECTRICAL
EXISTING RETURN AIR GRILLE
TO BE DEMOLISHED
REF: MECHANICAL
EXISTING 2 x 2 LIGHT FIXTURE
TO BE DEMOLISHED
REF: ELECTRICAL
EXISTING GYPSUM BOARD
CEILING TO REMAIN
2' x 2' ACOUSTICAL CEILING
2 x 2 LIGHT FIXTURE
REF: ELECTRICAL
CEILING HEIGHT, ABOVE
FINISH FLOOR
2 x 4 LIGHT FIXTURE
REF: ELECTRICAL
00'-00"
REFLECTED CEILING PLAN LEGEND
2' x 4' ACOUSTICAL CEILING
RETURN AIR GRILLE
REF: MECHANICAL
SUPPLY AIR DIFFUSER
REF: MECHANICAL
SUSPENDED LIGHT FIXTURE
REF: ELECTRICAL
DUCTLESS SPLIT INDOOR
UNIT; REF: MECHANICAL
EXHAUST AIR GRILLE
REF: MECHANICAL
+/- 11'-0" FV
'-9
1' -9
F
V
2.190
EX. COMM
114A
2.180
2.180
2.73
129 SF
TR
114A
6.09
6.09
3/ 4"
3/ 4"
1'
-9
F V
9.85
3/4"3/4"
5'-6 1/2" 2'-0" 3'-4"
5' -7
/2
2'
-6
3' -6
27.06 10.30
+/- 11'-0" FV
10'-10 1/2"
26.13
5' -7
+/- 13'-9" FV
3' -4
5'-5"8'-4"
5' -7
2.73
'-1
1" F
V
EX. COMM
2.73 2.180
105 SF
EX. COMM
5' -7
+/- 13'-9" FV
3' -4
5'-5"8'-4"
5' -7
'-1
1" F
V
+/- 11'-0" FV
1'
-9
F V
+/- 11'-0" FV
1'
-9
F V
129 SF
TR
114A
2.74
E Q
5' -3
/2
E
Q
5'-4" 5'-8"
23.06
23.06
10.32
STORAGE
MECH LOFT
'-0
F
V
EX. COMM
'-0
F
V
+/- 3'-7" FV
OFFICE AND
BREAK ROOM
2.73
EX. COMM
STORAGE
MECH LOFT
+/- 3'-7" FV
'-0
F
V
OFFICE AND
BREAK ROOM
EX. COMM
244B
2.73
2.73
'-4
1'
-2
1'
-5
/2
F V
1'-2 1/2" 14'-2"
+/- 15'-4 1/2" FV
175 SF
EX. COMM
244B
'-4
1'
-2
1'
-5
/2
F V
1'-2 1/2" 14'-2"
+/- 15'-4 1/2" FV
PARTITION LEGEND
1 HOUR FIRE RATED
2 HOUR FIRE RATED
SMOKE PARTITION/BARRIER
NEW NON-RATED WALLS
EXISTING WALL TO REMAIN
EXISTING 1 HOUR FIRE
EXISTING 2 HOUR FIRE
NOTE: NOT ALL SYMBOLS MAY BE USED
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
DRAWING TITLE PROJECT TITLE
LOCATION
DATE CHECKED DRAWN
PROJECT NUMBERCONSULTANTS:
DRAWING #
VA HEALTH CARE SYSTEM APPROVAL:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. BR 2171 EXP. 09/30/2025
ENGR REG. NO. F-17591 EXP. 02/28/2026
CIVIL ENGINEER
OLSSON
550 E. ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 890-8802
MECH / ELEC / PLUMB / TELECOM
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
RATED ENGINEERING
609 S. KELLY AVENUE, SUITE H2
EDMOND, OK 73003
(405) 210-5814
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
11140 S. TOWNE SQUARE, STE 100
ST. LOUIS, MO 63123
(314) 917-0148
STRUCTURAL ENGINEER
STAND STRUCTURAL ENGINEERING
8234 ROBINSON STREET
OVERLAND PARK, KS 66204
(913) 214-2169
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
DRAWING NUMBER
BUILDING NUMBER
/1
/2
:4 :4
P
M
BUILDINGS 1 AND MMRC-HZ5 (OFF-SITE)
- ENLARGED PLANS - LEVEL 1 AND
LEVEL 2
CAB 143 OF 478AJS
FINAL BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES DALLAS, TX
03/17/2025
549-21-700
DALLAS VA MEDICAL CENTER
4500 S LANCASTER RD
DALLAS, TX 75216
AE140
SPUR #: 2302
KEYNOTE LEGEND
2.73 EXISTING TR EQUIPMENT TO REMAIN. REF: GENERAL DEMOLITION NOTE 9 & TELECOM.
2.74 OPEN TO BOTTOM OF DECK ABOVE.
2.180 EXISTING EQUIPMENT TO REMAIN. REF: TELECOM.
2.190 DEMOLISH EXISTING TELECOM RACK. REF: TELECOM.
6.09 3/4" FIRE RATED PLYWOOD (4X8) MOUNTED 18" FROM FLOOR, PAINTED. REF: ROOM FINISH
SCHEDULE.
9.85 PATCH AND REPAIR EXISTING WALLS AFFECTED BY DEMOLITION WORK. FIRE CAULK AND
SEAL PENETRATIONS AS REQUIRED TO MAINTAIN FIRE AND/OR SMOKE RATING.
10.30 TELECOMMUNICATION RACK, REF: TELECOM
10.32 CABLE TRAY, REF: TELECOM
23.06 DUCTLESS SPLIT INDOOR UNIT MOUNTED ABOVE CABLE TRAY, REF: MECHANICAL
26.13 ELECTRICAL PANEL, REF: ELECTRICAL
27.06 GROUND BAR, REF: TELECOM
1 AND MMRC-HZ5
N
1/4" = 1'-0" 2/ A-112
BLDG1 - LEVEL 1 - OFF-SITE - 114A - DEMO PLAN3
N
1/4" = 1'-0" 2/ A-112
BLDG1 - LEVEL 1 - OFF-SITE - 114A - FLOOR PLAN4
N
1/4" = 1'-0" 1/ A-112
MMRC-HZ5 - LEVEL 1 - OFF-SITE - 117 - DEMO PLAN1
N
1/4" = 1'-0" 1/ A-112
MMRC-HZ5 - LEVEL 1 - OFF-SITE - 117 - FLOOR PLAN2
N
1/4" = 1'-0"
BLDG1 - LEVEL 1 - OFF-SITE - 114A - DEMO RCP5
N
1/4" = 1'-0"
BLDG1 - LEVEL 1 - OFF-SITE - 114A - RCP6
N
1/4" = 1'-0" 3/ A-112
MDRT - LEVEL 1 - OFF-SITE - 104 - DEMO PLAN9
N
1/4" = 1'-0" 3/ A-112
MDRT - LEVEL 1 - OFF-SITE - 104 - FLOOR PLAN10
N
1/4" = 1'-0" 4/ A-112
BLDG 1 - LEVEL 2 - OFF-SITE - 244B - DEMO PLAN7
N
1/4" = 1'-0" 4/ A-112
BLDG 1 - LEVEL 2 - OFF-SITE - 244B - FLOOR PLAN8
SHOWN FOR REFERENCE ONLY. NEW
TRS LOCATED AT 114A AND 229A.
SHOWN FOR REFERENCE ONLY. NEW
TRS LOCATED AT 114A AND 229A.
SHOWN FOR REFERENCE ONLY. NEW
TRS LOCATED AT 114A AND 229A.
No. REVISION DESCRIPTION DATE
The information on this document is preliminary or incomplete, not for
2. THE CONTRACTOR SHALL VERIFY DIMENSIONS OF EXISTING CONDITIONS, AND NOTIFY THE
ARCHITECT IN WRITING OF ANY DISCREPANCIES. ALL INFORMATION SHOWN ON THE
CONSTRUCTION DOCUMENTS IS BASED ON FIELD OBSERVATIONS AND/OR THE ORIGINAL
CONSTRUCTION DOCUMENTS OF THE FACILITY.
3. DEMOLITION AND CONSTRUCTION WORK MUST BE DONE UNDER NEGATIVE PRESSURE UTILIZING
HEPA FILTRATION UNITS. SEE INFECTION CONTROL NOTES AND SPECIFICATIONS.
4. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT OR AREA HAS BEEN
INSPECTED BY THE SAFETY OFFICER AND INFECTION CONTROL COORDINATOR AND
THOROUGHLY CLEANED BY ENVIRONMENTAL MANAGEMENT SERVICES.
5. THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING FOR EXISTING FLOOR, WALL AND
CEILING FINISHES IN EXISTING AREAS NOT DESIGNATED FOR DEMOLITION OR NEW
CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE
CAUSED BY THIER WORK OR ANY SUBCONTRACTOR.
6. THE CONTRACTOR SHALL VERIFY THAT NEW MECHANICAL SYSTEMS CAN BE INSTALLED IN
EXISTING SPACES TO CLEAR EXISTING CEILING AND OTHER CONSTRUCTED ITEMS AND MAINTAIN
FLOOR TO CEILING HEIGHTS INDICATED ON DRAWINGS. IF DISCREPANCIES OCCUR DUE TO
EXISTING CONDITIONS, CONSULT WITH THE ARCHITECT BEFORE PROCEEDING.
7. THE FINISH FACE OF MATERIAL OF NEW PARTITIONS SHALL ALIGN ON BOTH SIDES OF THE PARTITION WITH THE FACE OF THE MATERIALS ON EXISTING COLUMNS, WALLS, OR PARTITIONS, UNLESS NOTED OTHERWISE.
8. NO WORK TO BE DONE IN AREAS HATCHED GRAY IN PLANS, HOWEVER WORK MIGHT NEED TO BE
PERFORMED IN CEILING OR EXISTING CHASES THROUGHOUT BUILDING. REFERENCE
MECHANICAL AND ELECTRICAL DRAWINGS FOR EXTENT OF WORK. COORDINATE ACCESS TO
ROOMS OUTSIDE OF SCOPE WITH OWNER.
9. ALL EXISTING TELECOM EQUIPMENT TO REMAIN UNLESS NOTED OTHERWISE. REFER TO TELECOM
DRAWINGS.
GENERAL PLAN NOTES
1. ALL NEW DOOR FRAMES TO BE LOCATED 4" FROM OUTSIDE OF FRAME TO FINISH FACE OF
ADJACENT WALL UNLESS NOTED OTHERWISE.
2. FIRE CAULK ALL PENETRATIONS IN EXISTING WALLS, FLOORS, OR CEILINGS.
3. ALL WALLS TO GO TO DECK. IF EXISTING WALL DOES NOT CURRENTLY GO TO DECK,
CONTRACTOR TO EXTEND WALL SYSTEM UP TO EXISTING STRUCTURE ABOVE PRIOR TO FIRE
CAULKING. MAINTAINING EXISTING FIRE RATING.
4. ALL NEW CONSTRUCTION WALLS ARE DIMENSIONED TO CENTERLINE OF METAL STUD, UNLESS
NOTED OTHERWISE.
5. ALL EXISTING WALLS ARE DIMENSIONED TO FACE OF EXISTING FINISH, UNLESS NOTED
OTHERWISE.
6. ALL EXISTING GLAZING LOCATED IN EXTERIOR WALLS WITHIN EXISTING AND NEW TELECOM
ROOMS SHALL RECEIVE 15-MINUTE FORCED INTRUSION RESISTANT FILM & CONTACT SENSORS
TIED TO THE SECURITY CONTROL CENTER.
GENERAL REFLECTED CEILING PLAN NOTES
1. CEILINGS IN ALL TR'S ARE TO BE OPEN TO BOTTOM OF DECK, UNLESS NOTED OTHERWISE.
2. ALL SURFACES OF FURRDOWNS TO BE PAINTED TO MATCH UNLESS NOTED OTHERWISE.
3. ALL FIXTURES IN DEMOLISHED CEILINGS ARE TO FIRST BE REMOVED AND RETURNED TO OWNER, UNLESS NOTED OTHERWISE.
4. RECONFIGURE SPRINKLER SYSTEM IN DEMOLISHED CEILINGS PER FIRE PROTECTION
REQUIREMENTS.
5. ALL FIXTURES TO BE CENTERD IN ROOM UNLESS NOTED OTHERWISE.
NEW DOOR & FRAME
APPLICATION.
REF: DOOR SCHEDULE
DEMOLITION & NEW FLOOR PLAN LEGEND
AREA NOT IN ARCHITECTURAL
SCOPE, REF: OTHER
DISCIPLINES
EXISTING WALL TO BE
DEMOLISHED IN ITS ENTIRETY
EXISTING PARTITION TO
REMAIN & PROTECT
EXISTING DOOR & FRAME TO
REMAIN AND PROTECT
EXISTING FRAME TO REMAIN,
REMOVE EXISTING DOOR; REF:
KEY NOTES FOR DEMO NOTES.
EXISTING 2' x 2' ACOUSTICAL
CEILING TO BE DEMOLISHED
EXISTING GYPSUM BOARD
CEILING TO BE DEMOLISHED
EXISTING 2 x 4 LIGHT FIXTURE
TO BE DEMOLISHED
REF: ELECTRICAL
DEMOLITION REFLECTED CEILING PLAN LEGEND
EXISTING 2' x 4' ACOUSTICAL
CEILING TO BE DEMOLISHED
EXISTING SUPPLY AIR
DIFFUSER TO BE DEMOLISHED
REF: MECHANICAL
EXISTING EXHAUST AIR
GRILLE TO BE DEMOLISHED
REF: MECHANICAL
EXISTING SUSPENDED LIGHT
FIXTURE TO BE REMOVED
REF: ELECTRICAL
EXISTING RETURN AIR GRILLE
TO BE DEMOLISHED
REF: MECHANICAL
EXISTING 2 x 2 LIGHT FIXTURE
TO BE DEMOLISHED
REF: ELECTRICAL
EXISTING GYPSUM BOARD
CEILING TO REMAIN
2' x 2' ACOUSTICAL CEILING
2 x 2 LIGHT FIXTURE
REF: ELECTRICAL
CEILING HEIGHT, ABOVE
FINISH FLOOR
2 x 4 LIGHT FIXTURE
REF: ELECTRICAL
00'-00"
REFLECTED CEILING PLAN LEGEND
2' x 4' ACOUSTICAL CEILING
RETURN AIR GRILLE
REF: MECHANICAL
SUPPLY AIR DIFFUSER
REF: MECHANICAL
SUSPENDED LIGHT FIXTURE
REF: ELECTRICAL
DUCTLESS SPLIT INDOOR
UNIT; REF: MECHANICAL
EXHAUST AIR GRILLE
REF: MECHANICAL19'-0" 11'-6"
8'
-8
/2
F V2.22
EX. WORKROOM
3'-4"7'-8 1/2"3'-4"19'-8 1/2"
'-3
6.09
102 SF
TR
229A
8' -8
'-0
/2
19'-2" 11'-0 1/2"
8'
-8
/2
F V
D3
D3
229A-HZG
9-
H Z
G
3/ 4"
2' -1
1/
2" 2'
-9
4' -0
3/
4"
3/4"
3'-9"3'-1 1/2"3'-7 1/2"
3/4"
10.30
6.09
6.09
27.06
D3
WORK ROOM
LOBBY
229B
9.88
9.88
9.88
9.88
26.13
18'-11 1/2" 11'-5 1/2"
8' -5
/2
'-3
EX. WORK ROOM
TR
229A
WORK ROOM
LOBBY
229B
EQ5'-3"EQ
E Q
E Q
2.74
23.06
10.32
PARTITION LEGEND
1 HOUR FIRE RATED
2 HOUR FIRE RATED
SMOKE PARTITION/BARRIER
NEW NON-RATED WALLS
EXISTING WALL TO REMAIN
EXISTING 1 HOUR FIRE
EXISTING 2 HOUR FIRE
NOTE: NOT ALL SYMBOLS MAY BE USED
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
DRAWING TITLE PROJECT TITLE
LOCATION
DATE CHECKED DRAWN
PROJECT NUMBERCONSULTANTS:
DRAWING #
VA HEALTH CARE SYSTEM APPROVAL:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. BR 2171 EXP. 09/30/2025
ENGR REG. NO. F-17591 EXP. 02/28/2026
CIVIL ENGINEER
OLSSON
550 E. ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 890-8802
MECH / ELEC / PLUMB / TELECOM
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
RATED ENGINEERING
609 S. KELLY AVENUE, SUITE H2
EDMOND, OK 73003
(405) 210-5814
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
11140 S. TOWNE SQUARE, STE 100
ST. LOUIS, MO 63123
(314) 917-0148
STRUCTURAL ENGINEER
STAND STRUCTURAL ENGINEERING
8234 ROBINSON STREET
OVERLAND PARK, KS 66204
(913) 214-2169
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
DRAWING NUMBER
BUILDING NUMBER
/1
/2
:4 :4
P
M
BUILDINGS 1 AND MMRC-HZ5 (OFF-SITE)
- ENLARGED PLANS - LEVEL 2
CAB 144 OF 478AJS
FINAL BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES DALLAS, TX
03/17/2025
549-21-700
DALLAS VA MEDICAL CENTER
4500 S LANCASTER RD
DALLAS, TX 75216
AE141
SPUR #: 2302
KEYNOTE LEGEND
2.22 DEMOLISH EXISTING FLOORING AND BASE TO EXTENTS INDICATED; CLEAN & PREPARE
SUB-FLOOR SURFACE FOR NEW FLOORING.
2.74 OPEN TO BOTTOM OF DECK ABOVE.
6.09 3/4" FIRE RATED PLYWOOD (4X8) MOUNTED 18" FROM FLOOR, PAINTED. REF: ROOM FINISH
SCHEDULE.
9.88 PAINT NEW WALLS TO MATCH EXISTING AND INSTALL RUBBER BASE, REFER TO FINISH
SCHEDULE.
10.30 TELECOMMUNICATION RACK, REF: TELECOM
10.32 CABLE TRAY, REF: TELECOM
23.06 DUCTLESS SPLIT INDOOR UNIT MOUNTED ABOVE CABLE TRAY, REF: MECHANICAL
26.13 ELECTRICAL PANEL, REF: ELECTRICAL
27.06 GROUND BAR, REF: TELECOM
1 AND MMRC-HZ5
1/4" = 1'-0"
HRZG 1 - LEVEL 2 - 229A - DEMO PLAN11/4" = 1'-0"
HRZG 1 - LEVEL 2 - 229A - FLOOR PLAN2
1/4" = 1'-0"
HRZG 1 - LEVEL 2 - 229A - DEMO RCP31/4" = 1'-0"
HRZG 1 - LEVEL 2 - 229A - RCP4
NN
NN
No. REVISION DESCRIPTION DATE
The information on this document is preliminary or incomplete, not for th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
DRAWING TITLE PROJECT TITLE
LOCATION
DATE CHECKED DRAWN
PROJECT NUMBERCONSULTANTS:
DRAWING #
VA HEALTH CARE SYSTEM APPROVAL:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. BR 2171 EXP. 09/30/2025
ENGR REG. NO. F-17591 EXP. 02/28/2026
CIVIL ENGINEER
OLSSON
550 E. ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 890-8802
MECH / ELEC / PLUMB / TELECOM
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
RATED ENGINEERING
609 S. KELLY AVENUE, SUITE H2
EDMOND, OK 73003
(405) 210-5814
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
11140 S. TOWNE SQUARE, STE 100
ST. LOUIS, MO 63123
(314) 917-0148
STRUCTURAL ENGINEER
STAND STRUCTURAL ENGINEERING
8234 ROBINSON STREET
OVERLAND PARK, KS 66204
(913) 214-2169
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
DRAWING NUMBER
BUILDING NUMBER
/1
/2
:4 :4
P
M
DOOR SCHEDULE
CAB 145 OF 478AJS
FINAL BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES DALLAS, TX
03/17/2025
549-21-700
DALLAS VA MEDICAL CENTER
4500 S LANCASTER RD
DALLAS, TX 75216
AE601
SPUR #: 2302
DOOR SCHEDULE
vg ROOM NAME
DOOR PANEL FRAME HARDWARE
SET
COMMENTS
TYPE MATERIAL WIDTH HEIGHT FIRE RATING TYPE FINISH
BLDG 1
103-1 TR F WD 3'-6" 7'-0" 20 MIN. HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
212-1 TR F WD 3'-8" 7'-0" 20 MIN. HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
310-1 TR F WD 3'-6" 7'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
403-1 TR F WD 3'-6" 7'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
542-1 TR F WD 3'-6" 7'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
600D-1 OFFICE (TE) F MTL 3'-0" 7'-0" HM-1 PAINTED 04 EXISTING DOOR & FRAME TO REMAIN. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS.
BLDG 2
1C-301-2 TR F WD 3'-6" 7'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
1C-409U TR F WD 3'-0" 7'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
1D-217-2 TR F WD 3'-6" 7'-0" 20 MIN. HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
1D-217A-2 EX. FIRE ALARM F WD 2'-6" 7'-0" HM-1 PAINTED 03 NEW DOOR & FRAME. STOREROOM FUNCTION.
2C-104B-2 TR F WD 3'-0" 7'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
2D-40B1-2 TR F WD 3'-10" 7'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS.
2D-401-2 CLOSET F WD 3'-10" 7'-0" HM-1 PAINTED 03 NEW DOOR & FRAME. STOREROOM FUNCTION. FIELD VERIFY EXISTING ROUGH OPENING.
2D-401A-2 CLOSET F WD 3'-0" 7'-0" HM-1 PAINTED 03 NEW DOOR & FRAME. STOREROOM FUNCTION.
3C-236-2 TR F WD 3'-0" 7'-0" 20 MIN. HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
3C-477-2 TR F WD 3'-0" 7'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
4C-224-2 TR F WD 3'-4" 7'-0" 20 MIN. HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
4C-407-2 TR F WD 3'-0" 7'-0" 20 MIN. HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
5C-204-2 TR F WD 3'-8" 7'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
5C-435-2 TR F WD 3'-0" 7'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
6C-221-2 TR F WD 3'-0" 7'-0" 20 MIN. HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
6C-405-2 TR F WD 3'-0" 7'-0" 20 MIN. HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
7C-225-2 TR F WD 3'-0" 7'-0" 20 MIN. HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
7C-406-2 TR F WD 3'-0" 7'-0" 20 MIN. HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
8C-237-2 TR F WD 3'-0" 7'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
8C-409B-2 TR F WD 3'-6" 8'-0" 90 MIN. HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS.
9C-206-2 TR F WD 3'-0" 7'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
9C-206A-2 TR F WD 3'-0" 7'-0" HM-1 PAINTED 03 NEW DOOR & FRAME. STOREROOM FUNCTION.
BC-128-2 TR F WD 3'-0" 7'-0" 20 MIN. HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
BC-229-2 TR F WD 3'-0" 7'-0" 20 MIN. HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
BD-101A-2 TR F WD 3'-6" 8'-0" 90 MIN. HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS.
BLDG 2J
1A-206A-2J TR F WD 3'-6" 8'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS.
1A-453A-2J TR F WD 3'-6" 8'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS.
1B-210-2J TR F WD 3'-0" 7'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS.
1B-486A-2J TR F WD 3'-6" 8'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS.
3A-317A-2J TR F WD 3'-6" 8'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS.
3B-206-2J TR F WD 3'-6" 8'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS.
3B-409-2J TR F MTL 3'-0" 7'-0" 20 MIN. HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
5A-227-2J TR F WD 3'-0" 7'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
5A-227A-2J CLOSET F WD 2'-0" 7'-0" HM-1 PAINTED 03 NEW DOOR & FRAME. STOREROOM FUNCTION.
5B-138-2J TR F MTL 3'-6" 7'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
5B-313-2J TR F WD 3'-0" 7'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
5B-646-2J TR F WD 3'-6" 7'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS.
6-2J-D-2J MACHINE ROOM (TE) PAIR-F MTL 6'-0" 7'-0" HM-1 PAINTED 05 EXISTING DOOR & FRAME TO REMAIN. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS.
BA-301E1 TR F WD 3'-0" 7'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
BB-111 TR F WD 3'-0" 7'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS.
BB-210F1A-2
J
TR F WD 3'-6" 8'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS.
BLDG 3
017-3 TR F WD 3'-6" 7'-0" 20 MIN. HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
113-3 TR F WD 3'-6" 7'-0" 20 MIN. HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
BLDG 5
106-5 OFFICE (TE) F WD 3'-0" 7'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
BLDG 6
102A-6 CLOSET F WD 3'-0" 7'-0" HM-1 PAINTED 03 EXISTING DOOR AND FRAME TO BE REUSED. STOREROOM FUNCTION.
BLDG 8
103-8 POLICE (TE) F WD 3'-0" 7'-0" HM-1 PAINTED 04 EXISTING DOOR & FRAME TO REMAIN. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS.
BLDG 9
103-9 OFFICE (TE) F WD 2'-6" 7'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
BLDG 11
700A-11 OFFICE (TE) F WD 2'-6" 7'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
BLDG 13
300BA1-13 STORAGE F MTL 3'-0" 7'-0" HM-1 -- 01 NEW WIRE MESH DOOR. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS.
BLDG 43
109A-43 TR F MTL 3'-0" 7'-0" HM-1 PAINTED 02 NEW DOOR & FRAME. SALVAGE AND REUSE EXISTING ACCESS CONTROL EQUIPMENT.
207B-43 TR F MTL 3'-0" 7'-0" HM-1 PAINTED 02 NEW DOOR & FRAME. SALVAGE AND REUSE EXISTING ACCESS CONTROL EQUIPMENT.
G02-43 TR F MTL 3'-0" 7'-0" HM-1 PAINTED 02 NEW DOOR & FRAME. SALVAGE AND REUSE EXISTING ACCESS CONTROL EQUIPMENT.
BLDG 45
C118-45 TR F WD 3'-0" 7'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
BLDG 60
A155-60 TR F WD 3'-0" 7'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
A155A-60 CLOSET F WD 3'-6" 7'-0" HM-1 PAINTED 03 NEW DOOR & FRAME. STOREROOM FUNCTION.
B155-60 TR F WD 3'-0" 7'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
B155A OXYGEN STORAGE F WD 3'-6" 7'-0" HM-1 PAINTED 03 NEW DOOR & FRAME. STOREROOM FUNCTION.
C152-60 TR F WD 3'-0" 7'-0" 20 MIN. HM-1 PAINTED 02 NEW DOOR & FRAME. SALVAGE AND REUSE EXISTING ACCESS CONTROL EQUIPMENT.
BLDG 68
100-68 CLOSET (TE) F MTL 3'-0" 7'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
BLDG 69
A163-69 OFFICE (TE) F WD 3'-0" 7'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
BLDG 71
A121-71 TR F WD 3'-0" 7'-0" 20 MIN. HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
BLDG 72
206-72 TR F WD 3'-6" 7'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
BLDG 74
1B-116-74 TR F WD 3'-6" 8'-0" 20 MIN. HM-1 PAINTED 02 NEW DOOR & FRAME. SALVAGE AND REUSE EXISTING ACCESS CONTROL EQUIPMENT.
1C-164-74 TR F WD 3'-0" 7'-0" HM-1 PAINTED 02 NEW DOOR & FRAME. SALVAGE AND REUSE EXISTING ACCESS CONTROL EQUIPMENT.
BLDG 75
A110A-75 TR F WD 3'-0" 7'-0" 20 MIN. HM-1 PAINTED 02 NEW DOOR & FRAME. SALVAGE AND REUSE EXISTING ACCESS CONTROL EQUIPMENT.
BLDG 77
124-77 TR F WD 3'-0" 7'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
BLDG 80
102-80 TE F MTL 3'-0" 7'-0" 45 MIN. HM-1 PAINTED 04 EXISTING DOOR & FRAME TO REMAIN. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS.
BLDG 81
108-81 EX. TELECOM (TE) F MTL 3'-0" 7'-0" 20 MIN. HM-1 PAINTED 02 NEW DOOR & FRAME. SALVAGE AND REUSE EXISTING ACCESS CONTROL EQUIPMENT.
BLDG 82
BA101-82 TE F MTL 3'-0" 7'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
BA104-82 TE F WD 3'-0" 7'-0" HM-1 PAINTED 04 EXISTING DOOR & FRAME TO REMAIN. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS.
HZG
229-HZG WORK ROOM F WD 3'-0" 7'-0" HM-1 PAINTED 03 NEW DOOR & FRAME. STOREROOM FUNCTION.
229A-HZG TR F WD 3'-0" 7'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS. FIELD VERIFY EXISTING ROUGH OPENING.
TT46
105-TT46 OFFICE (TE) F WD 3'-0" 7'-0" HM-1 PAINTED 04 EXISTING DOOR & FRAME TO REMAIN. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS.
TT48
100-TT48 OFFICE F MTL 3'-0" 7'-0" HM-1 PAINTED 01 NEW DOOR & FRAME. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS.
TT49
111-TT49 F WD 3'-0" 7'-0" HM-1 PAINTED 04 EXISTING DOOR & FRAME TO REMAIN. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS.
TT50
106-TT50 OFFICE (TE) F WD 2'-6" 7'-0" HM-1 PAINTED 04 EXISTING DOOR & FRAME TO REMAIN. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS.
TT53
100-TT53 F MTL 3'-6" 7'-0" HM-1 PAINTED 04 EXISTING DOOR & FRAME TO REMAIN. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS.
TT54
122-TT54 TE F WD 3'-0" 7'-0" 20 MIN. HM-1 PAINTED 04 EXISTING DOOR & FRAME TO REMAIN. INSTALL NEW DUAL AUTHENTICATION (PIV AND PIN CODE) CARD READER. BADGE ACCESS BY OTHERS.
No. REVISION DESCRIPTION DATE
The information on this document is preliminary or incomplete, not for
2 1/2"
8.109
5.34
8.112
8.95
2.102
5.34
5' -4
F
.V
9.13
9.05
7.017.01
9.05
8.12
U.N.O.
4"
9.13
9.05
8.14
9.13
7.017.01
A
2" 5/
8"
1 15/16" VARIES 1 9/16"
1/2"
INT. STUD WALLS
WALL THICKNESS AT 1/2"
RE: DOOR SCHEDULE
FRAME DEPTH
F
SCHED. DIM.
S C
H E
D . D
IM
FFE
FLUSH
HM-1
NOTE: NOT ALL FRAME
ELEVATIONS MAY BE USED
2" S
C H
E D
. D
IM
2"
DIM.
SCHED. 2"
FFE
STANDARD FRAME
INTERIOR DETAILS:
HEAD:
JAMB:
HM-0
2" S
C H
E D
. D
IM
2"
DIM.
SCHED. 2"
FRAMED OPENING
INTERIOR DETAILS:
HEAD:
JAMB: /5 AE611
/6 AE611
F.F.
1/ 2"
8.113
8.115
7.02
2.104
22.03
7.78
WIDTH
ACTUAL
9.13
7.78
9.01
7.03
2.03
9.75
9.01
2.104
9.75
2.104
ALIGNALIGN
ALIGNALIGN
1' -0
4'
-0
9.89
6.06
9.77
7.190
9.53
9.53
5' -0
REFER TO PLANS FOR DIMENSION
VARIES
9.91
9.94
9.90
9.91
9.93
9.90 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
DRAWING TITLE PROJECT TITLE
LOCATION
DATE CHECKED DRAWN
PROJECT NUMBERCONSULTANTS:
DRAWING #
VA HEALTH CARE SYSTEM APPROVAL:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. BR 2171 EXP. 09/30/2025
ENGR REG. NO. F-17591 EXP. 02/28/2026
CIVIL ENGINEER
OLSSON
550 E. ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 890-8802
MECH / ELEC / PLUMB / TELECOM
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
RATED ENGINEERING
609 S. KELLY AVENUE, SUITE H2
EDMOND, OK 73003
(405) 210-5814
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
11140 S. TOWNE SQUARE, STE 100
ST. LOUIS, MO 63123
(314) 917-0148
STRUCTURAL ENGINEER
STAND STRUCTURAL ENGINEERING
8234 ROBINSON STREET
OVERLAND PARK, KS 66204
(913) 214-2169
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
DRAWING NUMBER
BUILDING NUMBER
/1
/2
:4 :5
P
M
DOOR & WINDOW DETAILS
CAB 146 OF 478AJS
FINAL BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES DALLAS, TX
03/17/2025
549-21-700
DALLAS VA MEDICAL CENTER
4500 S LANCASTER RD
DALLAS, TX 75216
AE611
SPUR #: 2302
3" = 1'-0"
DOOR FRAME TYPES3 1/4" = 1'-0"
DOOR TYPES11/4" = 1'-0"
HOLLOW METAL FRAME ELEVATIONS23" = 1'-0"
TYP. HM HEAD DETAIL - INTERIOR6 3" = 1'-0"
TYP. HM JAMB DETAIL - INTERIOR5
3" = 1'-0"
TYP. WINDOW COVER DETAIL11
KEYNOTE LEGEND
2.03 EXISTING WALL TO REMAIN.
2.102 EXISTING WINDOW (CONSTRUCTION MAY VARY)
2.104 EXISTING WALL PARTITION TO REMAIN IN PLACE, EXISTING WALL CONSTRUCTION MAY VARY
5.34 2" X 2" STEEL ANGLE FRAME SCREWED TOP, BOTTOM, SIDES TO ADJACENT WALLS / SILL.
SILL CONDITIONS VARY.
6.06 3/4" FRT PLYWOOD SHEATHING
7.01 SEALANT, COLOR MATCH TO WALL FINISH
7.02 BACKER-ROD & SEALANT, COLOR MATCH TO WALL FINISH
7.03 FIBERGLASS BALL INSULATION
7.78 THROUGH-PENETRATION FIRESTOP
7.190 FIRE CAULK ANY EXISTING OR NEW PENETRATIONS IN ALL WALLS, FLOOR, AND CEILING OF
NEW TR LOCATIONS
8.12 HOLLOW METAL DOOR & FRAME
8.14 HOLLOW METAL FRAME
8.95 REMOVE WINDOW GASKETING AND APPLY ANTIFRAGMENTATION LAMINATION TO EACH
WINDOW PANE. REINSTALL GASKETING AND PROVIDE CONTACT SENSORS.
8.109 1/2" DENSEGLASS PANEL BONDED TO 2" RIGID INSULATION CUT TO FIT WINDOW OPENING
8.112 BLACKOUT FILM ON TOP OF BLAST FILM (MATTE FINISH), APPLIED TO GLAZING
8.113 DOOR, REFER TO SCHEDULE
8.115 PROVIDE GASKET UNDER DOOR.
9.01 METAL STUD FRAMING SEE PARTITION TYPES SCHEDULE
9.05 3 5/8" C STUD
9.13 5/8" GYPSUM WALL BOARD
9.53 P1, REFERENCE SHEET AF711 FOR FINISH LEGEND AND FINISH SCHEDULES
9.75 GYPSUM BOARD ON METAL STUD FRAMING, REFER TO PLAN FOR WALL TYPE
9.77 CEILING
9.89 FLOOR FINISH PER FLOOR FINISH SCHEDULE
9.90 FLOORING MATERIAL (CPT1, LVT1, VCT1, WSF1)
9.91 FLOORING MATERIAL (CPT1, LVT1, VCT1, WSF1, SDT1)
9.93 TSI - WHEELED TRAFFIC TRANSITIONS
9.94 TSI - REDUCER TRANSITION
22.03 PLUMBING FIXTURE, SEE PLUMBING DRAWINGS
3" = 1'-0"
INTERIOR WOOD DOOR - SILL DETAIL4
3" = 1'-0"
PENETRATION DETAIL - FLOOR73" = 1'-0"
FIRE RATED WALL PENETRATION DETAIL81 1/2" = 1'-0"
NEW WALL TO EXISTING WALL91 1/2" = 1'-0"
EXISTING WALL INFILL10
3/4" = 1'-0"
INTERIOR ELEVATION - FIRE RATED PLYWOOD14 6" = 1'-0"
TR1 TRANSITION DETAIL126" = 1'-0"
TR2 TRANSITION DETAIL13
No. REVISION DESCRIPTION DATE
The information on this document is preliminary or incomplete, not for
1. ALL WOOD-LOOK PLANKS TO BE LAID IN THE SAME DIRECTION AS THE LONGEST DIMENSION OF
THE ROOM.
2. ALL RUBBERBASE TO BE RB1, UNO REF: ROOM FINISH SCHEDULE FOR EXCEPTIONS.
3. ALL NEW HOLLOW METAL DOOR FRAMES TO BE PAINTED TO MATCH EXISTING FINISH & COLOR.
4. ALL CONSTRUCTION SHALL CONFORM TO THE AMERICANS WITH DISABILITIES ACT, ACCESSIBILITY GUIDELINES (ADAAG), LOCAL GOVERNING FIRE, SAFETY, AND BUILDING CODES, REQUIREMENTS
AND REGULATIONS, 2015 IBC, ANSI A117.1-2003.
5. ALL DIMENSIONS ARE TO THE FACE OF EXISTING CONSTRUCTION OR CENTERLINE OF STUD
WALLS, UNLESS NOTED OTHERWISE.
6. ASBESTOS OR ASBESTOS CONTAINING PRODUCTS ARE NOT ALLOWED IN ANY ASPECT OF THIS
CONSTRUCTION.
7. COORDINATE ALL DISCIPLINES AND ALL ASPECTS OF WORK. CONFLICTS AND DISCREPENCIES
SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY.
8. ALL CONCRETE SURFACES WHICH RECEIVE A SPECIAL FINISH, FLOOR COVERING, COATINGS, HARDENERS, ETC. SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE SPECIFIC FINISH
MANUFACTURER'S SPECIFICATIONS AND INSTRUCTIONS. PRIOR TO APPLICATION OF A SPECIAL FINISH, A WRITTEN ACCEPTANCE OF THE SURFACE SHALL BE SUBMITTED TO THE ARCHITECT BY
THE GENERAL CONTRACTOR.
9. WHERE NOTED, REMOVE ALL FLOOR FINISHES AND ADHESVES AND STRIP FLOOR DOWN TO
EXISTING CONCRETE. PREP FLOOR FOR INSTALLATION OF NEW FLOOR FINISHES AS SHOWN
10. USE TR1 WHERE TRANSITIONS ARE LVT, CPT, SD, OR VCT TO CONCRETE, FIELD VERIFY
THICKNESS TO FLOORING USED.
11. USE TR2 WHERE TRANSITIONS ARE FLOORING MATERIAL TO FLOORING MATERIAL TRANSITIONS, FIELD VERIFY THICKNESS TO FLOORING LEGEND
12. ALL TRANSITIONS TO OCCUR CENTER OF DOOR PLANEL WHEN CLOSED.
GENERAL FINISH NOTES
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
DRAWING TITLE PROJECT TITLE
LOCATION
DATE CHECKED DRAWN
PROJECT NUMBERCONSULTANTS:
DRAWING #
VA HEALTH CARE SYSTEM APPROVAL:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. BR 2171 EXP. 09/30/2025
ENGR REG. NO. F-17591 EXP. 02/28/2026
CIVIL ENGINEER
OLSSON
550 E. ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 890-8802
MECH / ELEC / PLUMB / TELECOM
SPUR DESIGN
2519 MADISON AVE, SUITE 100
KANSAS CITY, MO 64108
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
RATED ENGINEERING
609 S. KELLY AVENUE, SUITE H2
EDMOND, OK 73003
(405) 210-5814
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
11140 S. TOWNE SQUARE, STE 100
ST. LOUIS, MO 63123
(314) 917-0148
STRUCTURAL ENGINEER
STAND STRUCTURAL ENGINEERING
8234 ROBINSON STREET
OVERLAND PARK, KS 66204
(913) 214-2169
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
DRAWING NUMBER
BUILDING NUMBER
/1
/2
:4 :5
P
M
FINISH SCHEDULES & DETAILS
CAB 147 OF 478AJS
FINAL BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES DALLAS, TX
03/17/2025
549-21-700
DALLAS VA MEDICAL CENTER
4500 S LANCASTER RD
DALLAS, TX 75216
AF711
SPUR #: 2302
ROOM FINISH SCHEDULE
BUILDING
NUMBER
ROOM # ROOM NAME
FLOOR FINISHES WALL FINISHES
CEILING AREA
MATERIAL BASE NORTH EAST SOUTH WEST
105 OFFICE ETR ETR ETR ETR ETR FRTP ETR 120 SF
BLDG 1
BLDG 1 103 TR SD1 RB1 FRTP FRTP FRTP FRTP OTS 141 SF
BLDG 1 212 TR SD1 RB1 FRTP FRTP FRTP FRTP OTS 123 SF
BLDG 1 310 TR SD1 RB1 FRTP FRTP FRTP FRTP OTS 125 SF
BLDG 1 403 TR SD1 RB1 FRTP FRTP FRTP FRTP OTS 128 SF
BLDG 1 542 TR SD1 RB1 FRTP FRTP FRTP FRTP OTS 125 SF
BLDG 1 600D OFFICE (TE) ETR ETR ETR ETR ETR FRTP ETR 112 SF
BLDG 2
BLDG 2 1C-C100 CORRIDOR ETR ETR ETR ETR P1 ETR ETR 131 SF
BLDG 2 BC-128A CLOSET ETR ETR P1 / FRTP ETR P1 ETR ETR 124 SF
BLDG 2 BD101 STORAGE ETR ETR P1 ETR P1 P1 ETR 747 SF
BLDG 2 BD-101A TR SD1 RB1 P1 / FRTP P1 / FRTP P1 / FRTP FRTP OTS 132 SF
BLDG 2 1C-301 CONFERENCE ETR ETR ETR ETR ETR P1 / WD ETR 1217 SF
BLDG 2 1C-301A TR SD1 RB1 FRTP P1 / FRTP FRTP FRTP OTS 88 SF
BLDG 2 1C-409U TR SD1 RB1 FRTP FRTP FRTP FRTP OTS 147 SF
BLDG 2 1D-217 TR SD1 RB1 FRTP P1 / FRTP FRTP FRTP OTS 151 SF
BLDG 2 1D-217A EX. FIRE ALARM ETR ETR ETR ETR ETR P1 ETR 31 SF
BLDG 2 2C-104B TR SD1 RB1 FRTP FRTP FRTP FRTP OTS 138 SF
BLDG 2 2C-412A TR SD1 RB1 FRTP FRTP FRTP FRTP ETR 182 SF
BLDG 2 2D401 CLOSET ETR ETR ETR ETR ETR ETR ETR 103 SF
BLDG 2 2D-401A CLOSET ETR ETR ETR ETR ETR ETR ETR 53 SF
BLDG 2 2D-401B TR SD1 RB1 FRTP FRTP FRTP P1 / FRTP OTS 159 SF
BLDG 2 3C-236 TR SD1 RB1 FRTP FRTP FRTP ETR OTS 130 SF
BLDG 2 3C-477 TR SD1 RB1 FRTP FRTP P1 / FRTP FRTP OTS 248 SF
BLDG 2 3C-477A OFFICE ETR RB1 P1 ETR ETR ETR ETR 254 SF
BLDG 2 4C-224 TR SD1 RB1 FRTP FRTP FRTP FRTP OTS 194 SF
BLDG 2 4C-407 TR SD1 RB1 FRTP FRTP FRTP FRTP OTS 160 SF
BLDG 2 5C-204 TR SD1 RB1 FRTP FRTP FRTP FRTP OTS 151 SF
BLDG 2 5C-435 TR SD1 RB1 FRTP FRTP FRTP FRTP OTS 106 SF
BLDG 2 6C-221 TR SD1 RB1 FRTP FRTP FRTP FRTP OTS 149 SF
BLDG 2 6C-405 TR SD1 RB1 P1 / FRTP FRTP FRTP FRTP OTS 84 SF
BLDG 2 6C-C400 CORRIDOR ETR RB1 ETR ETR P1 ETR ETR 148 SF
BLDG 2 7C-225 TR SD1 RB1 FRTP FRTP FRTP FRTP OTS 127 SF
BLDG 2 7C-406 TR SD1 RB1 FRTP FRTP…