Attachment 4 - Drawings Architectural - 2 of 2.pdf
PDF 15 MB Posted
- Solicitation number
- 36C77623B0066
About this file
This document provides details on a federal contract opportunity for construction services. The Department of Veterans Affairs Technology Acquisition Center Austin is soliciting proposals under solicitation number 36C77623B0066 for infrastructure upgrades at the Veterans Affairs Medical Center in Kansas City, Missouri. Attached are architectural drawings related to the project, which involves upgrading the EHRM infrastructure and totals 15MB in file size. Proposals are due by the date listed in the solicitation for the construction of these upgrades at the Kansas City VAMC facility. Relevant services, response dates, and the awarding agency are outlined for interested contractors to review.
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
OS OS
15.1 15.2 15.3
FIRST FLOOR
946' - 0"
FIFTH FLOOR
992' - 7 1/2"
SIXTH FLOOR
1004' - 2"
SEVENTH FLOOR
1015' - 8 1/2"
EIGHTH FLOOR
1027' - 3"
BLDG 15 BASEMENT
929' - 2"
Bldg 15 T.O. High Roof
1052' - 9 7/8"
Bldg 15 T.O. Low Roof
1038' - 7 1/2"
15AE-103
JOINT COVER PLATE
PARAPET TRIM
METAL PANEL SYSTEM
1' - 9"
1' - 9"EQ EQ
E Q
E Q
E Q
E Q
E Q
E Q
HORIZONTAL JOINT,
TYPICAL
VERTICAL JOINT, TYP
EXISTING LOUVER BEYOND
15.1.215.1.1
ROOF TOP UNIT
PER MECH
15.J 15.K
FIRST FLOOR
946' - 0"
SIXTH FLOOR
1004' - 2"
SEVENTH FLOOR
1015' - 8 1/2"
EIGHTH FLOOR
1027' - 3"
TENTH FLOOR
1050' - 4"
BLDG 15 BASEMENT
929' - 2"
15.L
Bldg 15 T.O. High Roof
1052' - 9 7/8"
Bldg 15 T.O. Low Roof
1038' - 7 1/2"
15AE-103
METAL PANEL SYSTEM
DOWN SPOUT
SCUPPER HEAD
PARAPET TRIM
JOINT COVER
PLATE
HORIZONTAL JOINT,
TYPICAL
VERTICAL JOINT,
TYPICAL
E Q
E Q
E Q
E Q
15 M
/2
E Q
E Q
1' - 8 3/8"1' - 9"
NEW ADDITIONEXISTING
SHOWN AREA
PROJECT
NORTH
BLDG 15
TOWER
FIRST FLOOR
946' - 0"
FIFTH FLOOR
992' - 7 1/2"
SIXTH FLOOR
1004' - 2"
SEVENTH FLOOR
1015' - 8 1/2"
EIGHTH FLOOR
1027' - 3"
BLDG 15 BASEMENT
929' - 2"
15.L
Bldg 15 T.O. High Roof
1052' - 9 7/8"
Bldg 15 T.O. Low Roof
1038' - 7 1/2"
15 M
JOINT COVER PLATE
/2
/2
/2
/2
METAL PANEL SYSTEM
HORIZONTAL JOINT,
TYPICAL
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
EHRM INFRASTRUCTURE
UPGRADES - KANSAS CITY, MO
KANSAS CITY VAMC 4801 LINWOOD BLVD KANSAS CITY, MO 64128
589-21-700
SPEES DESIGN BUILD
625 1ST AVE, STE 301
SEATTLE, WA 98104
(206) 590-2118
RAY SPEES 15AE-102
BLDG 15 TOWER - ELEVATION
MA/EM DD/ST
100% CONSTRUCTION
DOCUMENTS
06/19/2023
Revisions: Date:
1/4" = 1'-0"
BLDG 15 NORTH EXTERIOR ELEVATION
1/4" = 1'-0"
BLDG 15 WEST EXTERIOR ELEVATION
LEGEND
GENERAL NOTES
KEYNOTES (THIS SHEET ONLY)
KEY PLAN
1/4" = 1'-0"
BLDG 15 - EAST ELEVATION
07/19/2023ADDENDUM #1
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
(206) 590-2118
RAY SPEES
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
(206) 590-2118
RAY SPEES
SUB-BASEMENT
922' - 0"
15.1 15.2
BASEMENT FLOOR
934' - 0"
FIRST FLOOR
946' - 0"
SECOND FLOOR
958' - 0"
THIRD FLOOR
969' - 6 1/2"
SEVENTH FLOOR
1015' - 8 1/2"
EIGHTH FLOOR
1027' - 3"
BLDG 15 BASEMENT
929' - 2"
Bldg 15 T.O. Low Roof
1038' - 7 1/2"
15AE-103
168 SF
TR
F1-000
180 SF
CORRIDOR
C1-11
168 SF
TR
C1-12
168 SF
TR
F6-000
168 SF
TR
F7-000
168 SF
TR
F8-000
• TPO ROOFING MEMBRANE
• 1/2" COVER BOARD
• R-30ci RIGID INSULATION
SLOPE TO DRAIN
• VAPOR RETARDER
• 1/2" PLYWOOD SHEATHING
• 2 1/2" METAL DECK
COLUMN WRAP WITH
4" RECESSED BASE
AND TOP
J1 3/4" THK PRESSURE
TREATED PLYWOOD
LINER, TYP
LUCABOND SOFFIT
OVER 7/8" HAT
CHANNEL @ 2'-0" OC
5/8" GWB SHEATHING
OVER 2 1/2" METAL STUDS
FRAMING @ 2'-0" OC
JOINT FILLER
JOINT COVER PLATE
NEW ADDITION EXISTING
T Y
P
A-604B
JOINT FILLER
JOINT FILLER
JOINT FILLER
JOINT FILLER
A-604B
1A
SIM
A-604B
EXTERIOR WALL:
• 2" METAL PANEL SYSTEM
• R-10ci RIGID INSULATION
• WRB
• 5/8" EXTERIOR GYPSUM BOARD
• 3 5/8" METAL STUDS @ 16" OC
• R-15 BATT INSULATION
• VAPOR RETARDER
• 5/8" TYPE X GYPSUM BOARD
15.1.215.1.1
MECH ROOF TOP UNIT,
TYP
A-604C
2 HOUR FIRE RATED SHAFT WALL
• (2) 5/8" TYPE X GWB
• 2 1/2" C-H STUDS @ 2'-0" OC
• 1" SHAFT LINER
2 HOUR FIRE RATED FLOOR/CEILING
• 2 1/2" NORMAL WEIGHT CONCRETE
• 2", 18 GA DECK
• 2 HOUR SPRAY APPLY FIRE
RESISTIVE MATERIAL
A-604C
5'-0"
168 SF
TR
F3-000
15.J 15.K
BASEMENT FLOOR
934' - 0"
FIRST FLOOR
946' - 0"
SECOND FLOOR
958' - 0"
THIRD FLOOR
969' - 6 1/2"
SEVENTH FLOOR
1015' - 8 1/2"
EIGHTH FLOOR
1027' - 3"
BLDG 15 BASEMENT
929' - 2"
15.L
Bldg 15 T.O. Low Roof
1038' - 7 1/2"
15AE-103
A-604C
A-604B
1A
A-604B
168 SF
TR
F8-000
168 SF
TR
F7-000
168 SF
TR
F6-000
168 SF
TR
F3-000
168 SF
TR
C1-12
168 SF
TR
F1-000
180 SF
CORRIDOR
C1-11
44 SF
MICROSCOPY
F2-102B
J2
3/4" THK PRESSURE
TREATED PLYWOOD
LINER
L
E V
E L
O N
L Y
/2
V E
R
IF
Y
/2
LUCABOND SOFFIT
OVER 7/8" HAT
CHANNEL @ 2'-0" OC
5/8" GWB SHEATHING
OVER 2 1/2" METAL STUDS
FRAMING @ 2'-0" OC
10' - 0"
JOINT COVER PLATE
JOINT COVER PLATE
JOINT COVER PLATE
JOINT COVER PLATE
JOINT COVER PLATE
JOINT COVER PLATE
NEW ADDITIONEXISTING
A-604B
A-604B
• TPO ROOFING MEMBRANE
• 1/2" COVER BOARD
• R-30ci RIGID INSULATION
SLOPE TO DRAIN
• VAPOR RETARDER
• 1/2" PLYWOOD SHEATHING
• 2 1/2" METAL DECK
EXTERIOR WALL:
• 2" METAL PANEL SYSTEM
• R-10ci RIGID INSULATION
• WRB
• 5/8" EXTERIOR GYPSUM BOARD
• 3 5/8" METAL STUDS @ 16" OC
• R-15 BATT INSULATION
• VAPOR RETARDER
• 5/8" TYPE X GYPSUM BOARD
15 M
1' - 2" 4"
T Y
P
NEW LINTEL,
TYP
NEW LINTEL,
TYP
A-604C
M
IN
SPRAY APPLY FIREPROOFING @
ALL STRUCTURAL MEMBERS,
TYP
CABLE TRAY, TYP
LIGHT FIXTURE
SHOWN AREA
PROJECT
NORTH
BLDG 15
TOWER
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
EHRM INFRASTRUCTURE
UPGRADES - KANSAS CITY, MO
KANSAS CITY VAMC 4801 LINWOOD BLVD KANSAS CITY, MO 64128
589-21-700
SPEES DESIGN BUILD
625 1ST AVE, STE 301
SEATTLE, WA 98104
(206) 590-2118
RAY SPEES 15AE-103
BLDG 15 TOWER - SECTIONS
MA/EM DD
100% CONSTRUCTION
DOCUMENTS
06/19/2023
Revisions: Date:
1/4" = 1'-0"
BLDG 15 SECTION THRU NORTH
1/4" = 1'-0"
BLDG 15 SECTION THRU WEST
LEGEND
GENERAL NOTES
KEYNOTES (THIS SHEET ONLY)
KEY PLAN
07/19/2023ADDENDUM #1
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
(206) 590-2118
RAY SPEES
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
(206) 590-2118
SUB-BASEMENT
922' - 0"
15.J15.K
FIRST FLOOR
946' - 0"
SECOND FLOOR
958' - 0"
THIRD FLOOR
969' - 6 1/2"
SEVENTH FLOOR
1015' - 8 1/2"
EIGHTH FLOOR
1027' - 3"
BLDG 15 BASEMENT
929' - 2"
15.L
Bldg 15 T.O. Low Roof
1038' - 7 1/2"
15AE-103
15 M
123 SF
OFFICE
F-100A
168 SF
TR
F1-000
168 SF
TR
C1-12
168 SF
TR
F3-000
168 SF
TR
F6-000
168 SF
TR
F7-000
93 SF
CELL CULTURE
ROOM
F2-102A
95 SF
CELL CULTURE
ROOM
F3-102A
168 SF
TR
F8-000
3/4" THK PRESSURE
TREATED PLYWOOD
LINER
LUCABOND SOFFIT
OVER 7/8" HAT
CHANNEL @ 2'-0" OC
5/8" GWB SHEATHING
OVER 2 1/2" METAL STUDS
FRAMING @ 2'-0" OC
JOINT COVER PLATE
JOINT COVER PLATE
JOINT COVER PLATE
NEW ADDITION EXISTING
• TPO ROOFING MEMBRANE
• 1/2" COVER BOARD
• R-30ci RIGID INSULATION
SLOPE TO DRAIN
• VAPOR RETARDER
• 1/2" PLYWOOD SHEATHING
• 2 1/2" METAL DECK
EXTERIOR WALL:
• 2" METAL PANEL SYSTEM
• R-10ci RIGID INSULATION
• WRB
• 5/8" EXTERIOR GYPSUM BOARD
• 3 5/8" METAL STUDS @ 16" OC
• R-15 BATT INSULATION
• VAPOR RETARDER
• 5/8" TYPE X GYPSUM BOARD
A-604C
JOINT COVER PLATE
DATA RACK, TYP
CABLE TRAY, TYP
E1 E1
FIRE RESISTANT
PLYWOOD LINER, TYP
SHAFT WALL BEYOND
LUCABOND COLUMN
WRAP, TYP
V E
R
IF
Y
ELECT
PANEL, TYP
SPRAY APPLY
FIREPROOFING @ ALL
STRUCTURAL MEMBERS, TYP
SUB-BASEMENT
922' - 0"
15.115.2
FIRST FLOOR
946' - 0"
SECOND FLOOR
958' - 0"
THIRD FLOOR
969' - 6 1/2"
SEVENTH FLOOR
1015' - 8 1/2"
EIGHTH FLOOR
1027' - 3"
BLDG 15 BASEMENT
929' - 2"
Bldg 15 T.O. Low Roof
1038' - 7 1/2"
15AE-103
15AE-104
15.1.2 15.1.1
168 SF
TR
F8-000
168 SF
TR
F7-000
168 SF
TR
F6-000
168 SF
TR
F3-000
168 SF
TR
C1-12
168 SF
TR
F1-000
• TPO ROOFING MEMBRANE
• 1/2" COVER BOARD
• R-30ci RIGID INSULATION
SLOPE TO DRAIN
• VAPOR RETARDER
• 1/2" PLYWOOD SHEATHING
• 2 1/2" METAL DECK
COLUMN WRAP WITH
4" RECESSED BASE
AND TOP
3/4" THK PRESSURE
TREATED PLYWOOD
LINER, TYP
LUCABOND SOFFIT
OVER 7/8" HAT
CHANNEL @ 2'-0" OC
5/8" GWB SHEATHING
OVER 2 1/2" METAL STUDS
FRAMING @ 2'-0" OC
JOINT FILLER
JOINT COVER PLATE
NEW ADDITION
EXISTING
JOINT FILLER
JOINT FILLER
JOINT FILLER
JOINT FILLER
EXTERIOR WALL:
• 2" METAL PANEL SYSTEM
• R-10ci RIGID INSULATION
• WRB
• 5/8" EXTERIOR GYPSUM BOARD
• 3 5/8" METAL STUDS @ 16" OC
• R-15 BATT INSULATION
• VAPOR RETARDER
• 5/8" TYPE X GYPSUM BOARD
M20 J1
SHAFT WALL, TYP
J1
M20
E1
CABLE TRAY
DATA RACK
SHOWN AREA
PROJECT
NORTH
BLDG 15
TOWER
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
EHRM INFRASTRUCTURE
UPGRADES - KANSAS CITY, MO
KANSAS CITY VAMC 4801 LINWOOD BLVD KANSAS CITY, MO 64128
589-21-700
SPEES DESIGN BUILD
625 1ST AVE, STE 301
SEATTLE, WA 98104
(206) 590-2118
RAY SPEES 15AE-104
BLDG 15 TOWER - SECTIONS
MA/EM DD
100% CONSTRUCTION
DOCUMENTS
06/19/2023
Revisions: Date:
1/4" = 1'-0"
BLDG 15 SECTION - THRU NORTH LOOKING EAST
1/4" = 1'-0"
BLDG 15 SECTION - LOOKING NORTH
LEGEND
GENERAL NOTES
KEYNOTES (THIS SHEET ONLY)
KEY PLAN
07/19/2023ADDENDUM #1
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
(206) 590-2118
RAY SPEES
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
(206) 590-2118
DN
SHOWN AREA
PROJECT
NORTH
15.C
15.D
15.E
15.F
15.G
15.H
15.J
15.K
15.4 15.115.215.3
15.B
15.L
1.21
ELEVATOR NO.
E10
ELEVATOR
LOBBY
EB-F
MECH. ROOM
FB-100B
MECH. ROOM
FB-100
MECH. ROOM
FB-100A
SECTION 1A:
CONTRACTOR TO COORDINATE
WITH VA FOR ROOM CLOSURES
AND AVAILABILITY TO COMPLETE
DATA WIRING IN THIS AREA
MECHANICAL
MB-243
TRANSFER
DUCT
MB-243A
SECTION 1B:
CONTRACTOR TO COORDINATE
WITH VA FOR ROOM CLOSURES
AND AVAILABILITY TO COMPLETE
DATA WIRING IN THIS AREA
ICRA CLASS II
ICRA CLASS III
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
EHRM INFRASTRUCTURE
UPGRADES - KANSAS CITY, MO
KANSAS CITY VAMC 4801 LINWOOD BLVD KANSAS CITY, MO 64128
589-21-700
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
(206) 590-2118
RAY SPEES 15AS100
BUILDING 15 - LEVEL 00 - PHASING
PLAN 15
MA/EM CO
100% CONSTRUCTION
DOCUMENTS
06/19/2023
LEGENDLEGEND
KEY PLAN
1" = 10'-0"
BUILDING 15 - LEVEL 00 - PHASING PLAN
PROJECT
NORTH
0' 5' 10' 20'
Revisions: Date:
GENERAL NOTES
DUST MITIGATION NOTES
1. FOR THOSE CLOSETS IDENTIFIED TO REMAIN IN PLACE AND
BE REMODELED, THE CONTRACTOR SHALL WORK CLOSELY
WITH THE COR AND OIT TO PROTECT ALL EQUIPMENT FROM
THE HAZARDOUS EFFECTS OF DUST AND DEBRIS THAT WILL
BE GENERATED FROM CONSTRUCTION ACTIVITIES. THE
CONTRACTOR SHALL PROVIDE A LIST OF THOSE SPACES
THAT MAY BE ADVERSELY AFFECTED BY CONSTRUCTION TO
THE COR PRIOR TO THE START OF ANY CONSTRUCTION
ACTIVITIES.
2. CONTRACTOR SHALL SUBMIT A PLAN OF ACTION TO
MITIGATE THE EFFECTS OF DUST, DIRT AND DEBRIS WHICH
MAY INCLUDE THE FOLLOWING: PLASTIC SHEETING, CLEAN
AIR RECIRCULATION, SHORT DURATION POWER OUTAGES,
OFF HOURS WORK, ADDITIONAL CLEANING OF THE AREA
AFFECTED, TEMPORARY RELOCATION WITHIN THE ROOM OF
EQUIPMENT.
3. THE TYPES OF EQUIPMENT THAT MAY NEED PROTECTION
FROM CONSTRUCTION ACTIVITIES INCLUDES BUT IS NOT
LIMITED TO: RACK MOUNTED SERVERS, ROUTERS AND
SWITCH GEAR, FIRE ALARM PANELS, ACCESS CONTROL
PANELS, NURSE CALL, CCTV, SMOKE DETECTORS AND FIBER
OPTIC ENCLOSURES.
4. THE CONTRACTOR SHALL CLEAN ALL AREAS AFTER EACH
WORK PERIOD WITH VACUUMS THAT HAVE HEPA FILTERS IN
PLACE TO MINIMIZE THE RECIRCULATION OF DUST AND DIRT.
CONTRACTOR SHALL ALSO WIPE DOWN EQUIPMENT WITH
CLEANING WIPES TO ASSURE ANY EXCESS DUST IS
REMOVED.
5. THE CONTRACTOR SHALL PROVIDE PORTABLE COOLING AS
REQUIRED FOR ANY TELECOM RACKS REMAINING IN PLACE
DURING CONSTRUCTION ACTIVITIES.
A/E:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
(206) 590-2118
86 of 512Page 86 of 518
PROJECT
NORTH
ICRA CLASS II
ICRA CLASS III
ICRA CLASS IV
TR
TR
FIRE EXTINGUISHER CLOSETFEC
FIRE EXTINGUISHERFE
1.21
1.D.1
15.C
15.D
15.E
15.F
15.G
15.H
15.5
15.4 15.3
15.B
15.A
MECH.
SPRINKLER
VALVES
F1-101
CLINIC
RESEARCH
F1-105
OFFICE
F1-108A
OFFICE
F1-107A
CLINIC
RESEARCH
F1-107
CLINIC
RESEARCH
F1-109
OFFICE
F1-110A
OFFICE
F1-111
WORK ROOM
F1-113
OFFICE
F1-112A
MECH. ROOM
F1-117
CONFERENCE
ROOM
F1-119
OFFICE
F1-122
OFFICE
F1-123
OFFICE
F1-125A
OFFICE
F1-125
OFFICE
F1-129
OFFICE
F1-130
OFFICE
F1-132
OFFICE
F1-131
LOCKER,
FEMALE
F1-127
H.A.C.
F1-151
TOILET
F1-127A
STAIRWELL
S14
ELEVATOR
E10
ELEVATOR
E9
STAIRWELL
S20
CORRIDOR
C1-12
VESTIBULE
C1-10C
WORK ROOM
F1-137
OFFICE
F-100A
TR
F1-000
OFFICE
F1-100B
CLINIC
RESEARCH
F1-100
CLINIC
RESEARCH
F1-104
CLINIC
RESEARCH
F1-108
CLINIC
RESEARCH
F1-110
OFFICE
F1-112
OFFICE
F1-114
MECH. ROOM
F1-118
WORK ROOM
F1-120
15.2 15.1
15.J
15.K
15.L
CORRIDOR
C1-11
TR
PHASE 1: CONTRACTOR
TO COMPLETE THE WORK
OF THIS TR AND
ASSOCIATED DATA DROPS.
COMPLETE ONE
SECTION AT A TIME AS
DIRECTED TO COR.
SECTION 1A:
CONTRACTOR TO COORDINATE
WITH VA FOR ROOM
CLOSURES AND AVAILABILITY
TO COMPLETE DATA WIRING IN
THIS AREA
SECTION 1B:
CONTRACTOR TO COORDINATE
WITH VA FOR ROOM
CLOSURES AND AVAILABILITY
TO COMPLETE DATA WIRING IN
THIS AREA
15.1.2 15.1.1
15.M
FEC
FE
FEC
FEC
FAP
R 75' - 0"
LOBBY
C1-10B
DATA
M1-???
STORAGE
M1-209
STORAGE
M1-211
STORAGE
F1-153
FEC/FE REQUIRED WITHIN
75' RADIUS AROUND TR/TE
F1-000
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
EHRM INFRASTRUCTURE
UPGRADES - KANSAS CITY, MO
KANSAS CITY VAMC 4801 LINWOOD BLVD KANSAS CITY, MO 64128
589-21-700
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
(206) 590-2118
RAY SPEES 15AS101
BUILDING 15 - LEVEL 01 - PHASING
PLAN 15
MA/EM CO
100% CONSTRUCTION
DOCUMENTS
06/19/2023
LEGENDLEGEND
KEY PLAN
PROJECT
NORTH
1" = 10'-0"
BUILDING 15 - LEVEL 01 - PHASING PLAN
0' 5' 10' 20'
Revisions: Date:
GENERAL NOTES
DUST MITIGATION NOTES
1. FOR THOSE CLOSETS IDENTIFIED TO REMAIN IN PLACE AND
BE REMODELED, THE CONTRACTOR SHALL WORK CLOSELY
WITH THE COR AND OIT TO PROTECT ALL EQUIPMENT FROM
THE HAZARDOUS EFFECTS OF DUST AND DEBRIS THAT WILL
BE GENERATED FROM CONSTRUCTION ACTIVITIES. THE
CONTRACTOR SHALL PROVIDE A LIST OF THOSE SPACES
THAT MAY BE ADVERSELY AFFECTED BY CONSTRUCTION TO
THE COR PRIOR TO THE START OF ANY CONSTRUCTION
ACTIVITIES.
2. CONTRACTOR SHALL SUBMIT A PLAN OF ACTION TO
MITIGATE THE EFFECTS OF DUST, DIRT AND DEBRIS WHICH
MAY INCLUDE THE FOLLOWING: PLASTIC SHEETING, CLEAN
AIR RECIRCULATION, SHORT DURATION POWER OUTAGES,
OFF HOURS WORK, ADDITIONAL CLEANING OF THE AREA
AFFECTED, TEMPORARY RELOCATION WITHIN THE ROOM OF
EQUIPMENT.
3. THE TYPES OF EQUIPMENT THAT MAY NEED PROTECTION
FROM CONSTRUCTION ACTIVITIES INCLUDES BUT IS NOT
LIMITED TO: RACK MOUNTED SERVERS, ROUTERS AND
SWITCH GEAR, FIRE ALARM PANELS, ACCESS CONTROL
PANELS, NURSE CALL, CCTV, SMOKE DETECTORS AND FIBER
OPTIC ENCLOSURES.
4. THE CONTRACTOR SHALL CLEAN ALL AREAS AFTER EACH
WORK PERIOD WITH VACUUMS THAT HAVE HEPA FILTERS IN
PLACE TO MINIMIZE THE RECIRCULATION OF DUST AND DIRT.
CONTRACTOR SHALL ALSO WIPE DOWN EQUIPMENT WITH
CLEANING WIPES TO ASSURE ANY EXCESS DUST IS
REMOVED.
5. THE CONTRACTOR SHALL PROVIDE PORTABLE COOLING AS
REQUIRED FOR ANY TELECOM RACKS REMAINING IN PLACE
DURING CONSTRUCTION ACTIVITIES.
A/E:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
(206) 590-2118
87 of 512Page 87 of 518
NORTH
ICRA CLASS II
ICRA CLASS III
ICRA CLASS IV
TR
TR
FIRE EXTINGUISHER CLOSETFEC
FIRE EXTINGUISHERFE
1.21
15.C
15.D
15.E
15.F
15.G
15.H
15.5
15.4 15.3
15.B
15.A
STAIRWELL NO.
S14
379 SF
MECH. ROOM
F2-117
114 SF
LAB
F2-121
370 SF
MECHM ROOM
F2-116
75 SF
ELEVATOR NO.
E9
79 SF
ELEVATOR NO.
E10
13 SF
CLOSET
F2-101 92 SF
CELL CULTURE
ROOM
F2-102A
119 SF
CELL CULTURE
ROOM
F2-105A
91 SF
MICROSCOPY
F2-105B
25 SF
EMERGENCY
SHOWER
F2-103
742 SF
LAB
F2-105
12 SF
ICE MACHINE
F2-106
138 SF
WORKSTATION
F2-105C
134 SF
STORAGE
F2-107
120 SF
WORKSTATION
F2-102C
308 SF
LAB
EQUIPMENT
F2-110
111 SF
WORKSTATION
F2-126C
123 SF
BD FACSAria
FUSION ROOM
F2-126D
799 SF
LAB
F2-126
79 SF
MICROSCOPY
F2-126B
102 SF
CELL CULTURE
ROOM
F2-126A
58 SF
RESTROOM
F2-126E
35 SF
CARTS
F2-127B
140 SF
RECEPTION
F2-131A
112 SF
BREAK ROOM
F2-127
254 SF
CONFERENCE
ROOM
F2-125
142 SF
SHARED
STORAGE
F2-123
293 SF
COLLABORATION
ZONE
F2-131
297 SF
CORRIDOR
C2-12
189 SF
TR
F2-000
15.2 15.1
15.J
15.K
15.L
TR
PHASE 1: CONTRACTOR
TO COMPLETE THE WORK
OF THIS TR AND
ASSOCIATED DATA DROPS.
COMPLETE ONE
SECTION AT A TIME AS
DIRECTED TO COR.
SECTION 1A:
CONTRACTOR TO COORDINATE
WITH VA FOR ROOM
CLOSURES AND AVAILABILITY
TO COMPLETE DATA WIRING IN
THIS AREA
SECTION 1B:
CONTRACTOR TO COORDINATE
WITH VA FOR ROOM
CLOSURES AND AVAILABILITY
TO COMPLETE DATA WIRING IN
THIS AREA
815 SF
F2-002
R 75' - 0"
FAP
15.M
EQPT RM #2
M2-143
MRI
M2-145
MRI ANTE ROOM
M2-120
TOILET
M2-142TOILET
M2-144
CORRIDOR
C2-16
DRESS'G 4
M2-140
DRESS'G 2
M2-138
CONSULT
M2-136
CORRIDOR
C2-15
DRESS'G 1
M2-137
DRESS'G 3
M2-139
EMS CLOSET
M2-141
TOILET
M2-150
TOILET
M2-158A
ANTE
M2-157
STORAGE
M2-135
CORRIDOR
C2-10
FEC/FE REQUIRED WITHIN
75' RADIUS AROUND TR/TE
15.1.2
F2-000
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
EHRM INFRASTRUCTURE
UPGRADES - KANSAS CITY, MO
KANSAS CITY VAMC 4801 LINWOOD BLVD KANSAS CITY, MO 64128
589-21-700
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
(206) 590-2118
RAY SPEES 15AS102
BUILDING 15 - LEVEL 02 - PHASING
PLAN 15
MA/EM CO
100% CONSTRUCTION
DOCUMENTS
06/19/2023
LEGENDLEGEND
KEY PLAN
PROJECT
NORTH
0' 5' 10' 20'1" = 10'-0"
BUILDING 15 - LEVEL 02 - PHASING PLAN
Revisions: Date:
GENERAL NOTES
DUST MITIGATION NOTES
1. FOR THOSE CLOSETS IDENTIFIED TO REMAIN IN PLACE AND
BE REMODELED, THE CONTRACTOR SHALL WORK CLOSELY
WITH THE COR AND OIT TO PROTECT ALL EQUIPMENT FROM
THE HAZARDOUS EFFECTS OF DUST AND DEBRIS THAT WILL
BE GENERATED FROM CONSTRUCTION ACTIVITIES. THE
CONTRACTOR SHALL PROVIDE A LIST OF THOSE SPACES
THAT MAY BE ADVERSELY AFFECTED BY CONSTRUCTION TO
THE COR PRIOR TO THE START OF ANY CONSTRUCTION
ACTIVITIES.
2. CONTRACTOR SHALL SUBMIT A PLAN OF ACTION TO
MITIGATE THE EFFECTS OF DUST, DIRT AND DEBRIS WHICH
MAY INCLUDE THE FOLLOWING: PLASTIC SHEETING, CLEAN
AIR RECIRCULATION, SHORT DURATION POWER OUTAGES,
OFF HOURS WORK, ADDITIONAL CLEANING OF THE AREA
AFFECTED, TEMPORARY RELOCATION WITHIN THE ROOM OF
EQUIPMENT.
3. THE TYPES OF EQUIPMENT THAT MAY NEED PROTECTION
FROM CONSTRUCTION ACTIVITIES INCLUDES BUT IS NOT
LIMITED TO: RACK MOUNTED SERVERS, ROUTERS AND
SWITCH GEAR, FIRE ALARM PANELS, ACCESS CONTROL
PANELS, NURSE CALL, CCTV, SMOKE DETECTORS AND FIBER
OPTIC ENCLOSURES.
4. THE CONTRACTOR SHALL CLEAN ALL AREAS AFTER EACH
WORK PERIOD WITH VACUUMS THAT HAVE HEPA FILTERS IN
PLACE TO MINIMIZE THE RECIRCULATION OF DUST AND DIRT.
CONTRACTOR SHALL ALSO WIPE DOWN EQUIPMENT WITH
CLEANING WIPES TO ASSURE ANY EXCESS DUST IS
REMOVED.
5. THE CONTRACTOR SHALL PROVIDE PORTABLE COOLING AS
REQUIRED FOR ANY TELECOM RACKS REMAINING IN PLACE
DURING CONSTRUCTION ACTIVITIES.
A/E:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
(206) 590-2118
88 of 512Page 88 of 518
NORTH
ICRA CLASS II
ICRA CLASS III
ICRA CLASS IV
TR
TR
FIRE EXTINGUISHER CLOSETFEC
FIRE EXTINGUISHERFE
F3-000
1.F
1.J
1.21
1.D.1
15.C
15.D
15.E
15.F
15.G
15.H
15.5
15.4
15.B
15.A
15.1
93 SF
CELL CULTURE
ROOM
F3-102A
80 SF
MICROSCOPY
F3-102B
788 SF
LAB
F3-102
120 SF
WORKSTATION
F3-102C
309 SF
LAB
EQUIPMENT
F3-110
369 SF
MECH. ROOM
F3-116
368 SF
MECH. ROOM
F3-117
163 SF
STERILIZER
F3-121
123 SF
SPECIAL
EQUIPMENT
F3-120
112 SF
WORKSTATION
F3-126A
784 SF
LAB
F3-126260 SF
CONFERENCE
ROOM
F3-125
112 SF
BREAK ROOM
F3-127
34 SF
CARTS
F3-127B
58 SF
RESTROOM
F3-127A
79 SF
MICROSCOPY
F3-126C
102 SF
CELL CULTURE
ROOM
F3-126B
141 SF
CORRIDOR
C3-11
189 SF
TR
F3-000
127 SF
STAIRWELL NO.
S14
119 SF
CELL CULTURE
ROOM
F3-105A
89 SF
MICROSCOPY
F3-105B
161 SF
CORRIDOR
C3-11B
23 SF
EMERGENCY
SHOWER
F3-103
653 SF
LAB
F3-105
134 SF
STORAGE
F3-107
137 SF
WORKSTATION
F3-105C
12 SF
ICE MACHINE
F3-106
391 SF
CORRIDOR
C3-12
146 SF
RECEPTION
F3-131A
219 SF
COLLABORATION
ZONE
F3-131
13 SF
EMERGENCY
SHOWER
F3-126E
13 SF
CLOSET
F3-101
158 SF
STAIRWELL NO.
S20
253 SF
CORRIDOR
C3-10
77 SF
ELEVATOR
15.3 15.2
15.J
15.K
15.L
TR
PHASE 1: CONTRACTOR
TO COMPLETE THE WORK
OF THIS TR AND
ASSOCIATED DATA DROPS.
COMPLETE ONE
SECTION AT A TIME AS
DIRECTED TO COR.
SECTION 1A:
CONTRACTOR TO COORDINATE
WITH VA FOR ROOM
CLOSURES AND AVAILABILITY
TO COMPLETE DATA WIRING IN
THIS AREA.
SECTION 1B:
CONTRACTOR TO COORDINATE
WITH VA FOR ROOM
CLOSURES AND AVAILABILITY
TO COMPLETE DATA WIRING IN
THIS AREA
R
5'
0"
FAP
15.M
FEC/FE REQUIRED WITHIN
75' RADIUS AROUND TR/TE
15.1.2
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
EHRM INFRASTRUCTURE
UPGRADES - KANSAS CITY, MO
KANSAS CITY VAMC 4801 LINWOOD BLVD KANSAS CITY, MO 64128
589-21-700
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
(206) 590-2118
RAY SPEES 15AS103
BUILDING 15 - LEVEL 03 - PHASING
PLAN 15
MA/EM CO
100% CONSTRUCTION
DOCUMENTS
06/19/2023
LEGENDLEGEND
KEY PLAN
PROJECT
NORTH
0' 5' 10' 20'1" = 10'-0"
BUILDING 15 - LEVEL 03 - PHASING PLAN
Revisions: Date:
GENERAL NOTES
DUST MITIGATION NOTES
1. FOR THOSE CLOSETS IDENTIFIED TO REMAIN IN PLACE AND
BE REMODELED, THE CONTRACTOR SHALL WORK CLOSELY
WITH THE COR AND OIT TO PROTECT ALL EQUIPMENT FROM
THE HAZARDOUS EFFECTS OF DUST AND DEBRIS THAT WILL
BE GENERATED FROM CONSTRUCTION ACTIVITIES. THE
CONTRACTOR SHALL PROVIDE A LIST OF THOSE SPACES
THAT MAY BE ADVERSELY AFFECTED BY CONSTRUCTION TO
THE COR PRIOR TO THE START OF ANY CONSTRUCTION
ACTIVITIES.
2. CONTRACTOR SHALL SUBMIT A PLAN OF ACTION TO
MITIGATE THE EFFECTS OF DUST, DIRT AND DEBRIS WHICH
MAY INCLUDE THE FOLLOWING: PLASTIC SHEETING, CLEAN
AIR RECIRCULATION, SHORT DURATION POWER OUTAGES,
OFF HOURS WORK, ADDITIONAL CLEANING OF THE AREA
AFFECTED, TEMPORARY RELOCATION WITHIN THE ROOM OF
EQUIPMENT.
3. THE TYPES OF EQUIPMENT THAT MAY NEED PROTECTION
FROM CONSTRUCTION ACTIVITIES INCLUDES BUT IS NOT
LIMITED TO: RACK MOUNTED SERVERS, ROUTERS AND
SWITCH GEAR, FIRE ALARM PANELS, ACCESS CONTROL
PANELS, NURSE CALL, CCTV, SMOKE DETECTORS AND FIBER
OPTIC ENCLOSURES.
4. THE CONTRACTOR SHALL CLEAN ALL AREAS AFTER EACH
WORK PERIOD WITH VACUUMS THAT HAVE HEPA FILTERS IN
PLACE TO MINIMIZE THE RECIRCULATION OF DUST AND DIRT.
CONTRACTOR SHALL ALSO WIPE DOWN EQUIPMENT WITH
CLEANING WIPES TO ASSURE ANY EXCESS DUST IS
REMOVED.
5. THE CONTRACTOR SHALL PROVIDE PORTABLE COOLING AS
REQUIRED FOR ANY TELECOM RACKS REMAINING IN PLACE
DURING CONSTRUCTION ACTIVITIES.
A/E:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
(206) 590-2118
89 of 512Page 89 of 518
NORTH
ICRA CLASS II
ICRA CLASS III
ICRA CLASS IV
TR
TR
FIRE EXTINGUISHER CLOSETFEC
FIRE EXTINGUISHERFE
F4-000
1.F
1.J
1.21
1.D.1
15.C
15.D
15.E
15.F
15.G
15.H
15.J
15.K
15.5
15.4 15.115.215.3
15.B
15.A
15.L
OFFICE, CHIEF
M4-202
OFFICE
M4-201
CORRIDOR
C4-20
STORAGE
F4-100
MECH.
SPRINKLER
VALVES
F4-101
DARKROOM
F4-103
LAB
F4-104
LAB
F4-105
LAB
F4-108
COLD ROOM
F4-109
LAB
F4-110
COLD ROOM
F4-111
MECH. ROOM
F4-114
MECH. ROOM
F4-115
LAB
F4-117
LAB
F4-120
LAB
F4-125
LAB
F4-124
OFFICE
F4-127
OFFICE
F4-130
CONFERENCE
ROOM
F4-131
OFFICE
F4-130A
OFFICE
F4-130B
JAN. CLOSET
F4-151
STAFF LOCKER,
MALE
F4-153
CORRIDOR
C4-11
CORRIDOR
C4-12
ELEVATOR NO.
E10
ELEVATOR NO.
E9
STAIRWELL NO.
S20
STAIRWELL NO.
S14
RAD
CORRIDOR
C4-10
FAP
TR
F4-000
TR
PHASE 1: CONTRACTOR
TO COMPLETE THE WORK
OF THIS TR AND
ASSOCIATED DATA DROPS.
COMPLETE ONE
SECTION AT A TIME AS
DIRECTED TO COR.
SECTION 1A:
CONTRACTOR TO COORDINATE
WITH VA FOR ROOM
CLOSURES AND AVAILABILITY
TO COMPLETE DATA WIRING IN
THIS AREA.
SECTION 1B:
CONTRACTOR TO COORDINATE
WITH VA FOR ROOM
CLOSURES AND AVAILABILITY
TO COMPLETE DATA WIRING IN
THIS AREA.
R
5'
0"
15.M
FEC/FE REQUIRED WITHIN 75'
RADIUS AROUND TR/TE
15.1.2
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
EHRM INFRASTRUCTURE
UPGRADES - KANSAS CITY, MO
KANSAS CITY VAMC 4801 LINWOOD BLVD KANSAS CITY, MO 64128
589-21-700
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
(206) 590-2118
RAY SPEES 15AS104
BUILDING 15 - LEVEL 04 - PHASING
PLAN 15
MA/EM CO
100% CONSTRUCTION
DOCUMENTS
06/19/2023
LEGENDLEGEND
KEY PLAN
1" = 10'-0"
BUILDING 15 - LEVEL 04 - PHASING PLAN
PROJECT
NORTH
0' 5' 10' 20'
Revisions: Date:
GENERAL NOTES
DUST MITIGATION NOTES
1. FOR THOSE CLOSETS IDENTIFIED TO REMAIN IN PLACE AND
BE REMODELED, THE CONTRACTOR SHALL WORK CLOSELY
WITH THE COR AND OIT TO PROTECT ALL EQUIPMENT FROM
THE HAZARDOUS EFFECTS OF DUST AND DEBRIS THAT WILL
BE GENERATED FROM CONSTRUCTION ACTIVITIES. THE
CONTRACTOR SHALL PROVIDE A LIST OF THOSE SPACES
THAT MAY BE ADVERSELY AFFECTED BY CONSTRUCTION TO
THE COR PRIOR TO THE START OF ANY CONSTRUCTION
ACTIVITIES.
2. CONTRACTOR SHALL SUBMIT A PLAN OF ACTION TO
MITIGATE THE EFFECTS OF DUST, DIRT AND DEBRIS WHICH
MAY INCLUDE THE FOLLOWING: PLASTIC SHEETING, CLEAN
AIR RECIRCULATION, SHORT DURATION POWER OUTAGES,
OFF HOURS WORK, ADDITIONAL CLEANING OF THE AREA
AFFECTED, TEMPORARY RELOCATION WITHIN THE ROOM OF
EQUIPMENT.
3. THE TYPES OF EQUIPMENT THAT MAY NEED PROTECTION
FROM CONSTRUCTION ACTIVITIES INCLUDES BUT IS NOT
LIMITED TO: RACK MOUNTED SERVERS, ROUTERS AND
SWITCH GEAR, FIRE ALARM PANELS, ACCESS CONTROL
PANELS, NURSE CALL, CCTV, SMOKE DETECTORS AND FIBER
OPTIC ENCLOSURES.
4. THE CONTRACTOR SHALL CLEAN ALL AREAS AFTER EACH
WORK PERIOD WITH VACUUMS THAT HAVE HEPA FILTERS IN
PLACE TO MINIMIZE THE RECIRCULATION OF DUST AND DIRT.
CONTRACTOR SHALL ALSO WIPE DOWN EQUIPMENT WITH
CLEANING WIPES TO ASSURE ANY EXCESS DUST IS
REMOVED.
5. THE CONTRACTOR SHALL PROVIDE PORTABLE COOLING AS
REQUIRED FOR ANY TELECOM RACKS REMAINING IN PLACE
DURING CONSTRUCTION ACTIVITIES.
A/E:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
(206) 590-2118
90 of 512Page 90 of 518
FAS
1.21
1.D.1
15.C
15.D
15.E
15.F
15.G
15.H
15.J
15.K
15.5
15.4 15.115.215.3
15.B
15.A
15.L
OFFICE
F5-100
MECH.
SPRINKLER
VALVES
F5-101
CLINICAL
RESEARCH
F5-103
OFFICE
F5-105
MOTHER'S
ROOM
F5-106
ELEVATOR NO.
E10
STAIRWELL NO.
S14
CORRIDOR
C5-11
CLINICAL
RESEARCH
F5-108
CLINICAL
RESEARCH
F5-110
CLINICAL
RESEARCH
F5-109
CHEMICAL LAB
F5-112
ELECTRICS
SHOP
F5-111
MECH. ROOM
F5-116
MECH. ROOM
F5-117
LAB
F5-120
LAB / OFFICE
F5-121
CLINICAL
RESEARCH
F5-123
OFFICE
F5-124
OFFICE
F5-125
OFFICE
F5-125A
OFFICE
F5-126
CLINICAL
RESEARCH
F5-130
CORRIDOR
C5-12
ELEVATOR NO.
E9
STAIRWELL NO.
S20
CLINICAL
RESEARCH
F5-151
JAN. CLOSET
F5-153
TOILET, FEMALE
F5-155
63 SF
F5-106A
TR
F5-000 TR
PHASE 1: CONTRACTOR
TO COMPLETE THE WORK
OF THIS TR AND
ASSOCIATED DATA DROPS.
COMPLETE ONE
SECTION AT A TIME AS
DIRECTED TO COR.
SECTION 1A:
CONTRACTOR TO COORDINATE
WITH VA FOR ROOM
CLOSURES AND AVAILABILITY
TO COMPLETE DATA WIRING IN
THIS AREA
SECTION 1B:
CONTRACTOR TO COORDINATE
WITH VA FOR ROOM
CLOSURES AND AVAILABILITY
TO COMPLETE DATA WIRING IN
THIS AREA
R
5'
0"
15.M
BIOMED
NETWORK
CLOSET
F5-157
FEC/FE REQUIRED WITHIN
75' RADIUS AROUND TR/TE
15.1.2
ICRA CLASS II
ICRA CLASS III
ICRA CLASS IV
TR
TR
FIRE EXTINGUISHER CLOSETFEC
FIRE EXTINGUISHERFE
F5-000
SHOWN AREA
PROJECT
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
EHRM INFRASTRUCTURE
UPGRADES - KANSAS CITY, MO
KANSAS CITY VAMC 4801 LINWOOD BLVD KANSAS CITY, MO 64128
589-21-700
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
(206) 590-2118
RAY SPEES 15AS105
BUILDING 15 - LEVEL 05 - PHASING
PLAN 15
MA/EM RB
100% CONSTRUCTION
DOCUMENTS
06/19/2023
LEGENDLEGEND
KEY PLAN
1" = 10'-0"
BUILDING 15 - LEVEL 05 - PHASING PLAN
0' 5' 10' 20'
PROJECT
NORTH
Revisions: Date:
GENERAL NOTES
DUST MITIGATION NOTES
1. FOR THOSE CLOSETS IDENTIFIED TO REMAIN IN PLACE AND
BE REMODELED, THE CONTRACTOR SHALL WORK CLOSELY
WITH THE COR AND OIT TO PROTECT ALL EQUIPMENT FROM
THE HAZARDOUS EFFECTS OF DUST AND DEBRIS THAT WILL
BE GENERATED FROM CONSTRUCTION ACTIVITIES. THE
CONTRACTOR SHALL PROVIDE A LIST OF THOSE SPACES
THAT MAY BE ADVERSELY AFFECTED BY CONSTRUCTION TO
THE COR PRIOR TO THE START OF ANY CONSTRUCTION
ACTIVITIES.
2. CONTRACTOR SHALL SUBMIT A PLAN OF ACTION TO
MITIGATE THE EFFECTS OF DUST, DIRT AND DEBRIS WHICH
MAY INCLUDE THE FOLLOWING: PLASTIC SHEETING, CLEAN
AIR RECIRCULATION, SHORT DURATION POWER OUTAGES,
OFF HOURS WORK, ADDITIONAL CLEANING OF THE AREA
AFFECTED, TEMPORARY RELOCATION WITHIN THE ROOM OF
EQUIPMENT.
3. THE TYPES OF EQUIPMENT THAT MAY NEED PROTECTION
FROM CONSTRUCTION ACTIVITIES INCLUDES BUT IS NOT
LIMITED TO: RACK MOUNTED SERVERS, ROUTERS AND
SWITCH GEAR, FIRE ALARM PANELS, ACCESS CONTROL
PANELS, NURSE CALL, CCTV, SMOKE DETECTORS AND FIBER
OPTIC ENCLOSURES.
4. THE CONTRACTOR SHALL CLEAN ALL AREAS AFTER EACH
WORK PERIOD WITH VACUUMS THAT HAVE HEPA FILTERS IN
PLACE TO MINIMIZE THE RECIRCULATION OF DUST AND DIRT.
CONTRACTOR SHALL ALSO WIPE DOWN EQUIPMENT WITH
CLEANING WIPES TO ASSURE ANY EXCESS DUST IS
REMOVED.
5. THE CONTRACTOR SHALL PROVIDE PORTABLE COOLING AS
REQUIRED FOR ANY TELECOM RACKS REMAINING IN PLACE
DURING CONSTRUCTION ACTIVITIES.
A/E:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
(206) 590-2118
91 of 512Page 91 of 518
ICRA CLASS II
ICRA CLASS III
ICRA CLASS IV
TR
TR
FIRE EXTINGUISHER CLOSETFEC
FIRE EXTINGUISHERFE
1.F
1.J
1.21
1.D.1
1.E.1
15.C
15.D
15.E
15.F
15.G
15.H
15.J
15.K
15.5
15.4 15.115.215.3
15.B
15.A
15.L
57 SF
TOILET, MALE
F6-155
ELEVATOR NO.
E10
STAIRWELL NO.
S14
MECH.
SPRINKLER
VALVES
F6-101
LAB
F6-100
BIOMED
STORAGE
F6-103
BIOMED
STORAGE
F6-105
BIOMED
STORAGE
F6-107
STORAGE
F6-109
BIOMED LAB
F6-106
POLICE DEPT.
F6-111
OFFICE
F6-114
OFFICE
F6-114A
MECH. ROOM
F6-119
MECH. ROOM
F6-118
MACHINE ROOM
F6-123
BIOMED
ENGINEERING
F6-120
BIOMED
ENGINEERING
F6-130
MACHINE ROOM
F6-123A
STORAGE
F6-151
CORRIDOR
F6-112
CORRIDOR
C6-11
CORRIDOR
C6-10
ELEVATOR NO.
E9
STAIRWELL NO.
S20
OFFICE
F6-129
98 SF
F6-123A
TR
PHASE 1: CONTRACTOR
TO COMPLETE THE WORK
OF THIS TR AND
ASSOCIATED DATA DROPS.
COMPLETE ONE
SECTION AT A TIME AS
DIRECTED TO COR.
SECTION 1A:
CONTRACTOR TO COORDINATE
WITH VA FOR ROOM
CLOSURES AND AVAILABILITY
TO COMPLETE DATA WIRING IN
THIS AREA
SECTION 1B:
CONTRACTOR TO COORDINATE
WITH VA FOR ROOM
CLOSURES AND AVAILABILITY
TO COMPLETE DATA WIRING IN
THIS AREA
CORRIDOR
94 SF
CORRIDOR
FAP
R
5'
0"
FAP
15.M
191 SF
CORRIDOR
F6-001
49 SF
TOILET, FEMALE
F6-002
FEC/FE REQUIRED WITHIN
75' RADIUS AROUND TR/TE
TR
F6-000
189 SF
15.1.2
F6-000
SHOWN AREA
PROJECT
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
EHRM INFRASTRUCTURE
UPGRADES - KANSAS CITY, MO
KANSAS CITY VAMC 4801 LINWOOD BLVD KANSAS CITY, MO 64128
589-21-700
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
(206) 590-2118
RAY SPEES 15AS106
BUILDING 15 - LEVEL 06 - PHASING
PLAN 15
MA/EM ML
100% CONSTRUCTION
DOCUMENTS
06/19/2023
LEGEND
1" = 10'-0"
BUILDING 15 - LEVEL 06 - PHASING PLAN
PROJECT
NORTH
0' 5' 10' 20'
KEY PLAN
Revisions: Date:
GENERAL NOTES
DUST MITIGATION NOTES
1. FOR THOSE CLOSETS IDENTIFIED TO REMAIN IN PLACE AND
BE REMODELED, THE CONTRACTOR SHALL WORK CLOSELY
WITH THE COR AND OIT TO PROTECT ALL EQUIPMENT FROM
THE HAZARDOUS EFFECTS OF DUST AND DEBRIS THAT WILL
BE GENERATED FROM CONSTRUCTION ACTIVITIES. THE
CONTRACTOR SHALL PROVIDE A LIST OF THOSE SPACES
THAT MAY BE ADVERSELY AFFECTED BY CONSTRUCTION TO
THE COR PRIOR TO THE START OF ANY CONSTRUCTION
ACTIVITIES.
2. CONTRACTOR SHALL SUBMIT A PLAN OF ACTION TO
MITIGATE THE EFFECTS OF DUST, DIRT AND DEBRIS WHICH
MAY INCLUDE THE FOLLOWING: PLASTIC SHEETING, CLEAN
AIR RECIRCULATION, SHORT DURATION POWER OUTAGES,
OFF HOURS WORK, ADDITIONAL CLEANING OF THE AREA
AFFECTED, TEMPORARY RELOCATION WITHIN THE ROOM OF
EQUIPMENT.
3. THE TYPES OF EQUIPMENT THAT MAY NEED PROTECTION
FROM CONSTRUCTION ACTIVITIES INCLUDES BUT IS NOT
LIMITED TO: RACK MOUNTED SERVERS, ROUTERS AND
SWITCH GEAR, FIRE ALARM PANELS, ACCESS CONTROL
PANELS, NURSE CALL, CCTV, SMOKE DETECTORS AND FIBER
OPTIC ENCLOSURES.
4. THE CONTRACTOR SHALL CLEAN ALL AREAS AFTER EACH
WORK PERIOD WITH VACUUMS THAT HAVE HEPA FILTERS IN
PLACE TO MINIMIZE THE RECIRCULATION OF DUST AND DIRT.
CONTRACTOR SHALL ALSO WIPE DOWN EQUIPMENT WITH
CLEANING WIPES TO ASSURE ANY EXCESS DUST IS
REMOVED.
5. THE CONTRACTOR SHALL PROVIDE PORTABLE COOLING AS
REQUIRED FOR ANY TELECOM RACKS REMAINING IN PLACE
DURING CONSTRUCTION ACTIVITIES.
A/E:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
(206) 590-2118
92 of 512Page 92 of 518
15.1
15.H
15.J
15.K
15.4 15.215.3
15.L
15.C
15.D
15.E
15.F
15.G
15.5
15.B
15.A
1.J
1.21
1.D.1
RAD
115 SF
OFFICE
F7-100
660 SF
CORRIDOR
C7-11
161 SF
STAIRWELL NO.
S20
77 SF
ELEVATOR NO.
E9
186 SF
CONFERENCE
ROOM
F7-104A
187 SF
CONFERENCE
ROOM
F7-104
204 SF
CANCER
REGISTRY
F7-103
97 SF
OFFICE
F7-106A
400 SF
WORKROOM
F7-110
99 SF
OFFICE
F7-115
369 SF
MECH. ROOM
F7-120
362 SF
MECH. ROOM
F7-121
190 SF
COMPUTER
TRAINING
F7-125
203 SF
OFFICE
F7-124
987 SF
CLASSROOM
F7-130
99 SF
TOILET
F7-149
27 SF
JAN. CLOSET
F7-153
525 SF
CORRIDOR
C7-10
287 SF
CORRIDOR
C7-12
134 SF
STAIRWELL NO.
S14
15 SF
MECH.
SPRINKLER
F7-101
482 SF
LOGISTICS
F7-109
84 SF
ELEVATOR NO.
E10
190 SF
OFFICE
F7-105
97 SF
OFFICE
F7-106
203 SF
OFFICE
F7-117
105 SF
TOILET, FEMALE
F7-151
94 SF
Room
F7-100E
93 SF
Room
F7-100F
27 SF
JAN. CLOSET
F7-153
TR
PHASE 1:
CONTRACTOR
TO COMPLETE THE WORK OF THIS TR
AND ASSOCIATED DATA DROPS.
COMPLETE ONE SECTION AT A TIME
AS DIRECTED TO COR.
SECTION 1A:
CONTRACTOR TO COORDINATE
WITH VA FOR ROOM
CLOSURES AND AVAILABILITY
TO COMPLETE DATA WIRING IN
THIS AREA
SECTION 1B:
CONTRACTOR TO COORDINATE
WITH VA FOR ROOM
CLOSURES AND AVAILABILITY
TO COMPLETE DATA WIRING IN
THIS AREA
407 SF
187 SF
15.M
TR
F7-000
R
5'
BIOMED
NETWORK
CLOSET
F7-157
TOILET, MALE
F7-155
FEC/FE REQUIRED WITHIN
75' RADIUS AROUND TR/TE
15.1.2
SHOWN AREA
PROJECT
NORTH
F7-000
ICRA CLASS II
ICRA CLASS III
ICRA CLASS IV
TR
TR
FIRE EXTINGUISHER CLOSETFEC
FIRE EXTINGUISHERFE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
EHRM INFRASTRUCTURE
UPGRADES - KANSAS CITY, MO
KANSAS CITY VAMC 4801 LINWOOD BLVD KANSAS CITY, MO 64128
589-21-700
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
(206) 590-2118
RAY SPEES 15AS107
BUILDING 15 - LEVEL 07 - PHASING
PLAN 15
MA/EM JC
100% CONSTRUCTION
DOCUMENTS
06/19/2023
1" = 10'-0"
BUILDING 15 - LEVEL 07 - PHASING PLAN
LEGENDLEGEND
KEY PLAN
PROJECT
NORTH
0' 5' 10' 20'
Revisions: Date:
GENERAL NOTES
DUST MITIGATION NOTES
1. FOR THOSE CLOSETS IDENTIFIED TO REMAIN IN PLACE AND
BE REMODELED, THE CONTRACTOR SHALL WORK CLOSELY
WITH THE COR AND OIT TO PROTECT ALL EQUIPMENT FROM
THE HAZARDOUS EFFECTS OF DUST AND DEBRIS THAT WILL
BE GENERATED FROM CONSTRUCTION ACTIVITIES. THE
CONTRACTOR SHALL PROVIDE A LIST OF THOSE SPACES
THAT MAY BE ADVERSELY AFFECTED BY CONSTRUCTION TO
THE COR PRIOR TO THE START OF ANY CONSTRUCTION
ACTIVITIES.
2. CONTRACTOR SHALL SUBMIT A PLAN OF ACTION TO
MITIGATE THE EFFECTS OF DUST, DIRT AND DEBRIS WHICH
MAY INCLUDE THE FOLLOWING: PLASTIC SHEETING, CLEAN
AIR RECIRCULATION, SHORT DURATION POWER OUTAGES,
OFF HOURS WORK, ADDITIONAL CLEANING OF THE AREA
AFFECTED, TEMPORARY RELOCATION WITHIN THE ROOM OF
EQUIPMENT.
3. THE TYPES OF EQUIPMENT THAT MAY NEED PROTECTION
FROM CONSTRUCTION ACTIVITIES INCLUDES BUT IS NOT
LIMITED TO: RACK MOUNTED SERVERS, ROUTERS AND
SWITCH GEAR, FIRE ALARM PANELS, ACCESS CONTROL
PANELS, NURSE CALL, CCTV, SMOKE DETECTORS AND FIBER
OPTIC ENCLOSURES.
4. THE CONTRACTOR SHALL CLEAN ALL AREAS AFTER EACH
WORK PERIOD WITH VACUUMS THAT HAVE HEPA FILTERS IN
PLACE TO MINIMIZE THE RECIRCULATION OF DUST AND DIRT.
CONTRACTOR SHALL ALSO WIPE DOWN EQUIPMENT WITH
CLEANING WIPES TO ASSURE ANY EXCESS DUST IS
REMOVED.
5. THE CONTRACTOR SHALL PROVIDE PORTABLE COOLING AS
REQUIRED FOR ANY TELECOM RACKS REMAINING IN PLACE
DURING CONSTRUCTION ACTIVITIES.
A/E:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
(206) 590-2118
93 of 512Page 93 of 518
NORTH
15.B.8
15.C
15.D
15.E
15.F
15.G
15.H
15.J
15.K
15.4 15.115.215.3
15.B
15.A
15.L
1.21
ELEVATOR NO.
E10
WORK ROOM
F8-100
STAIRWELL NO.
S14
OFFICE
F8-105
OFFICE
F8-106
MEDICAL
LIBRARY
F8-120
MECH. ROOM
F8-123
MECH. ROOM
F8-122
LARGE FORMAT
PRINTING
F8-124
OFFICE
F8-126
OFFICE
F8-128
CLASSROOM
F8-129
OFFICE
F8-131
COPY CENTER
F8-132
OFFICE
F8-134
OFFICE
F8-132C
ELEVATOR NO.
E9
STAIRWELL NO.
S20
JAN. CLOSET
F8-153
CORRIDOR
C8-11
CORRIDOR
C8-10
CORRIDOR
C8-9
FEC
FE FAP
FAP
FAP
MECH.
SPRINKLER
VALVES
M8-226C
189 SF
TR
F8-000
396 SF
FB-120
117 SF
F8-104
183 SF
F8-107
268 SF
F8-109
402 SF
F8-127
397 SF
PHASE 1: CONTRACTOR TO
COMPLETE THE WORK OF THIS
TR AND ASSOCIATED DATA
DROPS. COMPLETE ONE
SECTION AT A TIME AS
DIRECTED TO COR.
TR
SECTION 1A:
CONTRACTOR TO COORDINATE
WITH VA FOR ROOM
CLOSURES AND AVAILABILITY
TO COMPLETE DATA WIRING IN
THIS AREA
SECTION 2A:
CONTRACTOR TO COORDINATE
WITH VA FOR ROOM
CLOSURES AND AVAILABILITY
TO COMPLETE DATA WIRING IN
THIS AREA
R 7 5' -
15.M
FEC/FE REQUIRED WITHIN
75' RADIUS AROUND TR/TE
15.1.2
F8-000
ICRA CLASS II
ICRA CLASS III
ICRA CLASS IV
TR
TR
FIRE EXTINGUISHER CLOSETFEC
FIRE EXTINGUISHERFE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
EHRM INFRASTRUCTURE
UPGRADES - KANSAS CITY, MO
KANSAS CITY VAMC 4801 LINWOOD BLVD KANSAS CITY, MO 64128
589-21-700
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
(206) 590-2118
RAY SPEES 15AS108
BUILDING 15 - LEVEL 08 - PHASING
PLAN 15
MA/EM DD/ADSI
100% CONSTRUCTION
DOCUMENTS
06/19/2023
LEGENDLEGEND
KEY PLAN
1" = 10'-0"
BUILDING 15 - LEVEL 08 - PHASING PLAN
0' 5' 10' 20'
PROJECT
NORTH
Revisions: Date:
GENERAL NOTES
DUST MITIGATION NOTES
1. FOR THOSE CLOSETS IDENTIFIED TO REMAIN IN PLACE AND
BE REMODELED, THE CONTRACTOR SHALL WORK CLOSELY
WITH THE COR AND OIT TO PROTECT ALL EQUIPMENT FROM
THE HAZARDOUS EFFECTS OF DUST AND DEBRIS THAT WILL
BE GENERATED FROM CONSTRUCTION ACTIVITIES. THE
CONTRACTOR SHALL PROVIDE A LIST OF THOSE SPACES
THAT MAY BE ADVERSELY AFFECTED BY CONSTRUCTION TO
THE COR PRIOR TO THE START OF ANY CONSTRUCTION
ACTIVITIES.
2. CONTRACTOR SHALL SUBMIT A PLAN OF ACTION TO
MITIGATE THE EFFECTS OF DUST, DIRT AND DEBRIS WHICH
MAY INCLUDE THE FOLLOWING: PLASTIC SHEETING, CLEAN
AIR RECIRCULATION, SHORT DURATION POWER OUTAGES,
OFF HOURS WORK, ADDITIONAL CLEANING OF THE AREA
AFFECTED, TEMPORARY RELOCATION WITHIN THE ROOM OF
EQUIPMENT.
3. THE TYPES OF EQUIPMENT THAT MAY NEED PROTECTION
FROM CONSTRUCTION ACTIVITIES INCLUDES BUT IS NOT
LIMITED TO: RACK MOUNTED SERVERS, ROUTERS AND
SWITCH GEAR, FIRE ALARM PANELS, ACCESS CONTROL
PANELS, NURSE CALL, CCTV, SMOKE DETECTORS AND FIBER
OPTIC ENCLOSURES.
4. THE CONTRACTOR SHALL CLEAN ALL AREAS AFTER EACH
WORK PERIOD WITH VACUUMS THAT HAVE HEPA FILTERS IN
PLACE TO MINIMIZE THE RECIRCULATION OF DUST AND DIRT.
CONTRACTOR SHALL ALSO WIPE DOWN EQUIPMENT WITH
CLEANING WIPES TO ASSURE ANY EXCESS DUST IS
REMOVED.
5. THE CONTRACTOR SHALL PROVIDE PORTABLE COOLING AS
REQUIRED FOR ANY TELECOM RACKS REMAINING IN PLACE
DURING CONSTRUCTION ACTIVITIES.
A/E:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
(206) 590-2118
94 of 512Page 94 of 518
15.4 15.3 15.2 15.1
15.L
15.K
15.J
15.H
15.G
15.F
15.E
15.D
15.C
15.A
Room
F9-150B
Room
F9-150
STAIRWELL NO.
S14
15.B
SECTION 1B:
CONTRACTOR TO COORDINATE
WITH VA FOR ROOM
CLOSURES AND AVAILABILITY
TO COMPLETE DATA WIRING IN
THIS AREA.
SECTION 1A:
CONTRACTOR TO COORDINATE
WITH VA FOR ROOM
CLOSURES AND AVAILABILITY
TO COMPLETE DATA WIRING IN
THIS AREA.
SHOWN AREA
PROJECT
NORTH
ICRA CLASS II
ICRA CLASS III
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
EHRM INFRASTRUCTURE
UPGRADES - KANSAS CITY, MO
KANSAS CITY VAMC 4801 LINWOOD BLVD KANSAS CITY, MO 64128
589-21-700
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
(206) 590-2118
RAY SPEES 15AS109
BUILDING 15 - LEVEL 09 - PHASING
PLAN 15
MA/EM ML/CO
100% CONSTRUCTION
DOCUMENTS
06/19/2023
1" = 10'-0"
BUILDING 15 - LEVEL 09 - PHASING PLAN
LEGENDLEGEND
KEY PLAN
0' 5' 10' 20'
PROJECT
NORTH
Revisions: Date:
GENERAL NOTES
DUST MITIGATION NOTES
1. FOR THOSE CLOSETS IDENTIFIED TO REMAIN IN PLACE AND
BE REMODELED, THE CONTRACTOR SHALL WORK CLOSELY
WITH THE COR AND OIT TO PROTECT ALL EQUIPMENT FROM
THE HAZARDOUS EFFECTS OF DUST AND DEBRIS THAT WILL
BE GENERATED FROM CONSTRUCTION ACTIVITIES. THE
CONTRACTOR SHALL PROVIDE A LIST OF THOSE SPACES
THAT MAY BE ADVERSELY AFFECTED BY CONSTRUCTION TO
THE COR PRIOR TO THE START OF ANY CONSTRUCTION
ACTIVITIES.
2. CONTRACTOR SHALL SUBMIT A PLAN OF ACTION TO
MITIGATE THE EFFECTS OF DUST, DIRT AND DEBRIS WHICH
MAY INCLUDE THE FOLLOWING: PLASTIC SHEETING, CLEAN
AIR RECIRCULATION, SHORT DURATION POWER OUTAGES,
OFF HOURS WORK, ADDITIONAL CLEANING OF THE AREA
AFFECTED, TEMPORARY RELOCATION WITHIN THE ROOM OF
EQUIPMENT.
3. THE TYPES OF EQUIPMENT THAT MAY NEED PROTECTION
FROM CONSTRUCTION ACTIVITIES INCLUDES BUT IS NOT
LIMITED TO: RACK MOUNTED SERVERS, ROUTERS AND
SWITCH GEAR, FIRE ALARM PANELS, ACCESS CONTROL
PANELS, NURSE CALL, CCTV, SMOKE DETECTORS AND FIBER
OPTIC ENCLOSURES.
4. THE CONTRACTOR SHALL CLEAN ALL AREAS AFTER EACH
WORK PERIOD WITH VACUUMS THAT HAVE HEPA FILTERS IN
PLACE TO MINIMIZE THE RECIRCULATION OF DUST AND DIRT.
CONTRACTOR SHALL ALSO WIPE DOWN EQUIPMENT WITH
CLEANING WIPES TO ASSURE ANY EXCESS DUST IS
REMOVED.
5. THE CONTRACTOR SHALL PROVIDE PORTABLE COOLING AS
REQUIRED FOR ANY TELECOM RACKS REMAINING IN PLACE
DURING CONSTRUCTION ACTIVITIES.
A/E:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
(206) 590-2118
95 of 512Page 95 of 518
NORTH
26.5
26.E
26.4a
/2
INTERIOR LINE
OF NEW WALLB B
B B
A
A
ENTRY
POINT
ENTRY
POINT
3' - 0"
3' - 0" 4' - 9 1/2"
REMOVE OLD
DOOR AFTER NEW
IS INSTALLED
1B B
3' - 0"
A
A
ENTRY
POINT
26.5
26.E
26.4a
26.E
26.4a
149 SF
STOCK ROOM
VB-713
3279 SF
RETAIL STORE
VB-715
100 SF
TR
VB-715A
69 SF
OFFICE
VB-715B
1079 SF
CORRIDOR
CB-60
01a
01b
VB-713
/2
8' - 5"
8' - 5"
NEW
FLOORING
EXISTING
FLOORING
10' x 8' TR
FORM FACTOR
VB-715A
26.E
26.4a
100 SF
TR
VB-715A
EXPOSED
1' - 1"
/2
/2
/2
3279 SF
RETAIL STORE
VB-715
149 SF
STOCK ROOM
VB-713
69 SF
OFFICE
VB-715B
1079 SF
CORRIDOR
CB-60
2' - 2 1/2"
1' - 1" 2' - 2 1/2"
/2
3279 SF
RETAIL STORE
VB-715
86 SF
IT CLOSET
VB-715A
164 SF
STOCK ROOM
VB-713
69 SF
OFFICE
VB-715B
1079 SF
CORRIDOR
CB-60
3279 SF
RETAIL STORE
VB-715
86 SF
IT CLOSET
VB-715A
164 SF
STOCK ROOM
VB-713
69 SF
OFFICE
VB-715B
1079 SF
CORRIDOR
CB-60
RM VB-713
EXISTING DOOR TO REMAIN
NEW DOOR
TO DEMOLISH
EXISTING DOOR TO DEMOLISH
EXISTING WALL TO DEMOLISH
EXISTING LIGHTS TO DEMOLISH
NEW LIGHTS (SEE ELECTRICAL DETAILS)
POLYETHYLENE SHEETING
CONSTRUCTION TACKY MATT
HEPA EQUIPPED AIR FILTER
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
EHRM INFRASTRUCTURE
UPGRADES - KANSAS CITY, MO
KANSAS CITY VAMC 4801 LINWOOD BLVD KANSAS CITY, MO 64128
589-21-700
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
(206) 590-2118
RAY SPEES 26A-100
BLDG 26 - LEVEL 00 - DEMO,
FLOOR PLANS & RCPS 26
MA/EM DD/KB/CO
100% CONSTRUCTION
DOCUMENTS
06/19/2023
LEGEND
KEY NOTES (THIS SHEET ONLY)
1/4" = 1'-0"
RM VB-715A - DEMO FLOOR PLAN
1/4" = 1'-0"
RM VB-715A - DEMO RCP
1/4" = 1'-0"
RM VB-715A - FLOOR PLAN
1/4" = 1'-0"
RM VB-715A - RCP
PROJECT
NORTH
PROJECT
NORTH
PROJECT
NORTH
PROJECT
NORTH
DEMOLISH EXISTING WALL. PREPARE FOR NEW
DOOR/FRAME.
DEMOLISH EXISTING DOOR/FRAME.
DEMOLISH EXISTING WALL. PATCH WALLS WHERE DEMO
OCCURS.
DEMOLISH EXISTING FLOORING TO EXPOSE CONCRETE SLAB
UNDERNEATH, REMOVE EXISTING ADHESIVE.
DEMOLISH EXISTING ACT COMPLETELY INCLUDING ALL GRID,
SUPPORTING WIRES, CLIPS, AND PERIMETER WALL ANGLES
IN ROOM TO EXPOSE UNDERSIDE OF STRUCTURE ABOVE.
INSTALL NEW DOOR/FRAME.
INFILL WALL, PATCH AND PAINT TO MATCH EXISTING.
CONSTRUCT NEW WALL, PATCH AND PAINT TO MATCH
EXISTING.
APPLY ANTI-STATIC COATING TO EXPOSED CONCRETE
FLOOR. PROVIDE VINYL REDUCER STRIP AT EXISTING
FLOORING TRANSITION.
INSTALL NEW RESILIENT RUBBER BASE AT ROOM
PERIMETER WITH SEALANT AT THE BOTTOM.
INSTALL NEW FRT PLYWOOD OVER WALLS PER DETAIL
3/AE421, TYPICAL.
INSTALL FIRE RETARDANT POLYETHYLENE SHEETING TO
ISOLATE CONSTRUCTION ZONE. TAPE AND SEAL ALONG
EDGES AND ANY AREAS WHERE POTENTIAL DUST MAY BE
EXPOSED OUTSIDE OF CONSTRUCTION AREA.
PLACE ADHESIVE WALK-OFF MATS AT ENTRANCE AND EXIT
OF CONSTRUCTION AREA. TYPICAL.
KEY PLAN
GENERAL NOTES
1. ALL PRODUCTS AND WALL FINISHES SHALL MATCH EXISTING
OR ADJACENT EXISTING UNLESS OTHERWISE NOTED.
2. PATCH AND REPAIR WALLS, FLOORS AND CEILING WHERE
MECHANICAL, PLUMBING, AND ELECTRICAL ITEMS ARE
DEMOLISHED.
3. PROTECT FINISHES IN ROOMS ADJACENT TO THE AREA OF
WORK AND PARTS THAT ARE NOT INCLUDED IN THE SCOPE.
4. CONTRACTORS SHALL LEAVE FIRE RATING STAMP
UNPAINTED AND VISIBLE ON THE NEW INSTALLED FRT
PLYWOOD. SEE DETAIL 5/AE421.
5. REFER TO SHEET AS101 FOR ICRA REQUIREMENTS AND
DETAILS.
6. PATCH AND REPAIR CEILING, WALLS AND FLOORS AS
REQUIRED WHERE ICRA BARRIERS WILL BE CONSTRUCTED
AND REMOVED.
7. PATCH AND REPAIR GWB WHERE DOOR IS DEMOLISHED AND
A NEW DOOR WILL BE INSTALLED.
A
B
ICRA CLASS II
ICRA LEGEND
ICRA KEY NOTES
Revisions: Date:
A/E:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
(206) 590-2118
96 of 512Page 96 of 518
OS
OS
J T
1.3d26.3
26.E
ENTRY POINT
A B
B
/2
1.3d26.3
26.E
23 SF
STORAGE
V1-684A
34 SF
TE
V1-685
127 SF
TR
V1-684
119 SF
OFFICE
V1-682
100 SF
EXAM ROOM
V1-781
98 SF
EXAM ROOM
V1-783
687 SF
CORRIDOR
C1-63
V -6
RADIATION
SHIELDED
WALL
01c
9' - 1"
"N E
W
F L O
O R
IN
G
E X
IS
T
IN
G
O
O R
IN
G
10' x 8' TR
FORM FACTOR
1.3d26.3
26.E
1.3d26.3
26.E
127 SF
TR
V1-684
687 SF
CORRIDOR
C1-63
34 SF
TE
V1-685
23 SF
STORAGE
V1-684A
687 SF
CORRIDOR
C1-63
573 SF
CHECK-IN/OUT
V1-706
EXPOSED
1' - 4"
/2
1' - 4"
0' - 8"
/2
1' - 4"
137 SF
SUPPLY ROOM
V1-684
34 SF
ELEC
V1-685
23 SF
STORAGE
V1-684A
119 SF
OFFICE
V1-682
100 SF
EXAM ROOM
V1-781
98 SF
EXAM ROOM
V1-783
687 SF
CORRIDOR
C1-63
137 SF
SUPPLY ROOM
V1-684
34 SF
ELEC
V1-685
23 SF
STORAGE
V1-684A
119 SF
OFFICE
V1-682
100 SF
EXAM ROOM
V1-781
98 SF
EXAM ROOM
V1-783
687 SF
CORRIDOR
C1-63
V1-684
EXISTING DOOR TO REMAIN
NEW DOOR
TO DEMOLISH
EXISTING DOOR TO DEMOLISH
EXISTING WALL TO DEMOLISH
EXISTING LIGHTS TO DEMOLISH
NEW LIGHTS (SEE ELECTRICAL DETAILS)
SHOWN AREA
PROJECT
NORTH
POLYETHYLENE SHEETING
CONSTRUCTION TACKY MATT
HEPA EQUIPPED AIR FILTER
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
EHRM INFRASTRUCTURE
UPGRADES - KANSAS CITY, MO
KANSAS CITY VAMC 4801 LINWOOD BLVD KANSAS CITY, MO 64128
589-21-700
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
(206) 590-2118
RAY SPEES 26A-101
BLDG 26 - LEVEL 01 - DEMO,
FLOOR PLANS & RCPS 26
MA/EM DD/ML/CO
100% CONSTRUCTION
DOCUMENTS
06/19/2023
LEGEND
1/4" = 1'-0"
RM V1-684 - DEMO FLOOR PLAN
1/4" = 1'-0"
RM V1-684 - FLOOR PLAN
1/4" = 1'-0"
RM V1-684 - DEMO RCP
1/4" = 1'-0"
RM V1-684 - RCP
PROJECT
NORTH
PROJECT
NORTH
PROJECT
NORTH
DEMOLISH EXISTING DOOR/FRAME.
DEMOLISH EXISTING FLOORING TO EXPOSE CONCRETE SLAB
UNDERNEATH. REMOVE EXISTING ADHESIVE. PREPARE
FLOORING FOR NEW WORK.
DEMOLISH EXISTING ACT COMPLETELY INCLUDING ALL
GRIDS, SUPPORTING WIRES, CLIPS, AND PERIMETER WALL
ANGLES TO EXPOSE UNDERSIDE OF STRUCTURE ABOVE.
PATCH WALLS WHERE CEILING IS REMOVED.
INSTALL NEW DOOR/FRAME.
APPLY ANTI-STATIC COATING TO EXPOSED CONCRETE
FLOOR. PROVIDE VINYL REDUCER STRIP AT EXISTING
FLOORING TRANSITION.
INSTALL NEW RESILIENT RUBBER BASE AT ROOM PERIMETER
WITH SEALANT AT THE BOTTOM.
INSTALL NEW FRT PLYWOOD OVER WALLS PER DETAIL
3/AE421, TYPICAL.
INSTALL FIRE RETARDANT POLYETHYLENE SHEETING TO
ISOLATE CONSTRUCTION ZONE. TAPE AND SEAL ALONG
EDGES AND ANY AREAS WHERE POTENTIAL DUST MAY BE
EXPOSED OUTSIDE OF CONSTRUCTION AREA.
PLACE ADHESIVE WALK-OFF MATS AT ENTRANCE AND EXIT
OF CONSTRUCTION AREA. TYPICAL.
KEY NOTES (THIS SHEET ONLY)
KEY PLAN
GENERAL NOTES
1. ALL PRODUCTS AND WALL FINISHES SHALL MATCH EXISTING
OR ADJACENT EXISTING UNLESS OTHERWISE NOTED.
2. PATCH AND REPAIR WALLS, FLOORS AND CEILING WHERE
MECHANICAL, PLUMBING, AND ELECTRICAL ITEMS ARE
DEMOLISHED.
3. PROTECT FINISHES IN ROOMS ADJACENT TO THE AREA OF
WORK AND PARTS THAT ARE NOT INCLUDED IN THE SCOPE.
4. CONTRACTORS SHALL LEAVE FIRE RATING STAMP
UNPAINTED AND VISIBLE ON THE NEW INSTALLED FRT
PLYWOOD. SEE DETAIL 5/AE421.
5. REFER TO SHEET AS101 FOR ICRA REQUIREMENTS AND
DETAILS.
6. PATCH AND REPAIR CEILING, WALLS AND FLOORS AS
REQUIRED WHERE ICRA BARRIERS WILL BE CONSTRUCTED
AND REMOVED.
7. PATCH AND REPAIR GWB WHERE DOOR IS DEMOLISHED AND
A NEW DOOR WILL BE INSTALLED.
ICRA CLASS II
ICRA LEGEND
A
B
PROJECT
NORTH
ICRA KEY NOTES
Revisions: Date:
A/E:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 203
KENT, WA 98032
(206) 590-2118
97 of 512Page 97 of 518
J
PROJECT
NORTH
RM V2-751A
26.3
26.D
26.E
26.D.1
5' - 0"
5' - 0 1/2"
/2
3' - 0" 5' - 0"
B B
A
B B
A
B B
A
26.3
26.D
26.E
26.D.1
82 SF
LOCKERS, MALE
V2-751
175 SF
CORRIDOR
C2-72
30 SF
TOILET, FEMALE
V2-749A
55 SF
TOILET, MALE
V2-751A
112 SF
A X-RAY ROOM
V2-756
103 SF
B X-RAY ROOM
V2-758
111 SF
LOCKERS,
FEMALE
V2-749
26.3
26.D
26.E
26.D.1
174 SF
LOCKERS, MALE
V2-751
418 SF
CORRIDOR
C2-71
175 SF
CORRIDOR
C2-72
103 SF
B X-RAY ROOM
V2-758
112 SF
A X-RAY ROOM
V2-756
130 SF
TR
V2-749
IN-03.01-11
01a
01b
V2-749
11' - 10 1/2"
/2
11' - 10 1/2"
NEW
FLOORING
EXISTING
FLOORING
10' x 10' TR
FORM FACTOR
26.3
26.D
26.E
26.D.1
418 SF
CORRIDOR
C2-71
174 SF
LOCKERS, MALE
V2-751
175 SF
CORRIDOR
C2-72
112 SF
A X-RAY ROOM
V2-756
103 SF
B X-RAY ROOM
V2-758
130 SF
TR
V2-749
EXPOSED
/2
/2
2' - 0 1/2" 2' - 0 1/2"
/2
82 SF
LOCKERS, MALE
V2-751
175 SF
CORRIDOR
C2-72
30 SF
TOILET, FEMALE
V2-749A
55 SF
TOILET, MALE
V2-751A
112 SF
A X-RAY ROOM
V2-756
103 SF
B X-RAY ROOM
V2-758
111 SF
LOCKERS,
FEMALE
V2-749
POLYETHYLENE SHEETING
CONSTRUCTION TACKY MATT
HEPA EQUIPPED AIR FILTER
EXISTING DOOR TO REMAIN
NEW DOOR
TO DEMOLISH
EXISTING DOOR TO DEMOLISH
EXISTING WALL TO DEMOLISH
EXISTING LIGHTS TO DEMOLISH
2HR FIRE RATED WALL
NEW LIGHTS (SEE ELECTRICAL DETAILS)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 -…
This is the start of the file's text. The full file is on GovTribe.