Attachment 4 - Drawings Architectural - 2 of 2.pdf

PDF 15 MB Posted

Attached to
Y1DA--EHRM Infrastructure Upgrades Construction Kansas City, MO (VA-23-00068037)
Solicitation number
36C77623B0066
Issued by

About this file

This document provides details on a federal contract opportunity for construction services. The Department of Veterans Affairs Technology Acquisition Center Austin is soliciting proposals under solicitation number 36C77623B0066 for infrastructure upgrades at the Veterans Affairs Medical Center in Kansas City, Missouri. Attached are architectural drawings related to the project, which involves upgrading the EHRM infrastructure and totals 15MB in file size. Proposals are due by the date listed in the solicitation for the construction of these upgrades at the Kansas City VAMC facility. Relevant services, response dates, and the awarding agency are outlined for interested contractors to review.

View the file

Other files

File Type Posted
Copy of Attachment 1 - Technical Questions - Responses.xlsx XLSX spreadsheet
36C77623B0066 0002.docx DOCX document
Attachment 1 - Site Visit - Sign-In Sheet - 36C77623B0066 EHRM Infra Upgrade - KC.pdf PDF
36C77623B0066 0001.docx DOCX document
Attachment 11 - Drawings Electrical - 6 of 8.pdf PDF
Attachment 19 - Drawings Telecommunications - 2 of 3.pdf PDF
Attachment 1 - Specifications - DIV 1-13.pdf PDF
Attachment 18 - Drawings Telecommunications - 1 of 3.pdf PDF
Attachment 3 - Drawings Architectural - 1 of 2.pdf PDF
Attachment 16 - Drawings Structural.pdf PDF
Attachment 7 - Drawings Electrical - 2 of 8.pdf PDF
Attachment 13 - Drawings Electrical - 8 of 8.pdf PDF
Attachment 14 - Drawings Environmental.pdf PDF
Attachment 10 - Drawings Electrical - 5 of 8.pdf PDF
Attachment 12 - Drawings Electrical - 7 of 8.pdf PDF
Attachment 22 - Wage Rates - 6-30-23.pdf PDF
Attachment 21 - Limitations on Subcontracting - Construction.docx DOCX document
Attachment 9 - Drawings Electrical - 4 of 8.pdf PDF
Attachment 23 - Contractor Safety - Environmental Form.docx DOCX document
Attachment 6 - Drawings Electrical - 1 of 8.pdf PDF
Attachment 17 - Drawings Technology.pdf PDF
Attachment 2 - Specifications - DIV 21-32.pdf PDF
Attachment 8 - Drawings Electrical - 3 of 8.pdf PDF
36C77623B0066_1.docx DOCX document
Attachment 20 - Drawings Telecommunications - 3 of 3.pdf PDF
Attachment 5 - Drawings Civil.pdf PDF
Attachment 15 - Drawings Mechanical.pdf PDF
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

OS OS

15.1 15.2 15.3

FIRST FLOOR

946' - 0"

FIFTH FLOOR

992' - 7 1/2"

SIXTH FLOOR

1004' - 2"

SEVENTH FLOOR

1015' - 8 1/2"

EIGHTH FLOOR

1027' - 3"

BLDG 15 BASEMENT

929' - 2"

Bldg 15 T.O. High Roof

1052' - 9 7/8"

Bldg 15 T.O. Low Roof

1038' - 7 1/2"

15AE-103

JOINT COVER PLATE

PARAPET TRIM

METAL PANEL SYSTEM

1' - 9"

1' - 9"EQ EQ

E Q

E Q

E Q

E Q

E Q

E Q

HORIZONTAL JOINT,

TYPICAL

VERTICAL JOINT, TYP

EXISTING LOUVER BEYOND

15.1.215.1.1

ROOF TOP UNIT

PER MECH

15.J 15.K

FIRST FLOOR

946' - 0"

SIXTH FLOOR

1004' - 2"

SEVENTH FLOOR

1015' - 8 1/2"

EIGHTH FLOOR

1027' - 3"

TENTH FLOOR

1050' - 4"

BLDG 15 BASEMENT

929' - 2"

15.L

Bldg 15 T.O. High Roof

1052' - 9 7/8"

Bldg 15 T.O. Low Roof

1038' - 7 1/2"

15AE-103

METAL PANEL SYSTEM

DOWN SPOUT

SCUPPER HEAD

PARAPET TRIM

JOINT COVER

PLATE

HORIZONTAL JOINT,

TYPICAL

VERTICAL JOINT,

TYPICAL

E Q

E Q

E Q

E Q

15 M

/2

E Q

E Q

1' - 8 3/8"1' - 9"

NEW ADDITIONEXISTING

SHOWN AREA

PROJECT

NORTH

BLDG 15

TOWER

FIRST FLOOR

946' - 0"

FIFTH FLOOR

992' - 7 1/2"

SIXTH FLOOR

1004' - 2"

SEVENTH FLOOR

1015' - 8 1/2"

EIGHTH FLOOR

1027' - 3"

BLDG 15 BASEMENT

929' - 2"

15.L

Bldg 15 T.O. High Roof

1052' - 9 7/8"

Bldg 15 T.O. Low Roof

1038' - 7 1/2"

15 M

JOINT COVER PLATE

/2

/2

/2

/2

METAL PANEL SYSTEM

HORIZONTAL JOINT,

TYPICAL

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

EHRM INFRASTRUCTURE

UPGRADES - KANSAS CITY, MO

KANSAS CITY VAMC 4801 LINWOOD BLVD KANSAS CITY, MO 64128

589-21-700

SPEES DESIGN BUILD

625 1ST AVE, STE 301

SEATTLE, WA 98104

(206) 590-2118

RAY SPEES 15AE-102

BLDG 15 TOWER - ELEVATION

MA/EM DD/ST

100% CONSTRUCTION

DOCUMENTS

06/19/2023

Revisions: Date:

1/4" = 1'-0"

BLDG 15 NORTH EXTERIOR ELEVATION

1/4" = 1'-0"

BLDG 15 WEST EXTERIOR ELEVATION

LEGEND

GENERAL NOTES

KEYNOTES (THIS SHEET ONLY)

KEY PLAN

1/4" = 1'-0"

BLDG 15 - EAST ELEVATION

07/19/2023ADDENDUM #1

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 203

KENT, WA 98032

(206) 590-2118

RAY SPEES

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 203

KENT, WA 98032

(206) 590-2118

RAY SPEES

SUB-BASEMENT

922' - 0"

15.1 15.2

BASEMENT FLOOR

934' - 0"

FIRST FLOOR

946' - 0"

SECOND FLOOR

958' - 0"

THIRD FLOOR

969' - 6 1/2"

SEVENTH FLOOR

1015' - 8 1/2"

EIGHTH FLOOR

1027' - 3"

BLDG 15 BASEMENT

929' - 2"

Bldg 15 T.O. Low Roof

1038' - 7 1/2"

15AE-103

168 SF

TR

F1-000

180 SF

CORRIDOR

C1-11

168 SF

TR

C1-12

168 SF

TR

F6-000

168 SF

TR

F7-000

168 SF

TR

F8-000

• TPO ROOFING MEMBRANE

• 1/2" COVER BOARD

• R-30ci RIGID INSULATION

SLOPE TO DRAIN

• VAPOR RETARDER

• 1/2" PLYWOOD SHEATHING

• 2 1/2" METAL DECK

COLUMN WRAP WITH

4" RECESSED BASE

AND TOP

J1 3/4" THK PRESSURE

TREATED PLYWOOD

LINER, TYP

LUCABOND SOFFIT

OVER 7/8" HAT

CHANNEL @ 2'-0" OC

5/8" GWB SHEATHING

OVER 2 1/2" METAL STUDS

FRAMING @ 2'-0" OC

JOINT FILLER

JOINT COVER PLATE

NEW ADDITION EXISTING

T Y

P

A-604B

JOINT FILLER

JOINT FILLER

JOINT FILLER

JOINT FILLER

A-604B

1A

SIM

A-604B

EXTERIOR WALL:

• 2" METAL PANEL SYSTEM

• R-10ci RIGID INSULATION

• WRB

• 5/8" EXTERIOR GYPSUM BOARD

• 3 5/8" METAL STUDS @ 16" OC

• R-15 BATT INSULATION

• VAPOR RETARDER

• 5/8" TYPE X GYPSUM BOARD

15.1.215.1.1

MECH ROOF TOP UNIT,

TYP

A-604C

2 HOUR FIRE RATED SHAFT WALL

• (2) 5/8" TYPE X GWB

• 2 1/2" C-H STUDS @ 2'-0" OC

• 1" SHAFT LINER

2 HOUR FIRE RATED FLOOR/CEILING

• 2 1/2" NORMAL WEIGHT CONCRETE

• 2", 18 GA DECK

• 2 HOUR SPRAY APPLY FIRE

RESISTIVE MATERIAL

A-604C

5'-0"

168 SF

TR

F3-000

15.J 15.K

BASEMENT FLOOR

934' - 0"

FIRST FLOOR

946' - 0"

SECOND FLOOR

958' - 0"

THIRD FLOOR

969' - 6 1/2"

SEVENTH FLOOR

1015' - 8 1/2"

EIGHTH FLOOR

1027' - 3"

BLDG 15 BASEMENT

929' - 2"

15.L

Bldg 15 T.O. Low Roof

1038' - 7 1/2"

15AE-103

A-604C

A-604B

1A

A-604B

168 SF

TR

F8-000

168 SF

TR

F7-000

168 SF

TR

F6-000

168 SF

TR

F3-000

168 SF

TR

C1-12

168 SF

TR

F1-000

180 SF

CORRIDOR

C1-11

44 SF

MICROSCOPY

F2-102B

J2

3/4" THK PRESSURE

TREATED PLYWOOD

LINER

L

E V

E L

O N

L Y

/2

V E

R

IF

Y

/2

LUCABOND SOFFIT

OVER 7/8" HAT

CHANNEL @ 2'-0" OC

5/8" GWB SHEATHING

OVER 2 1/2" METAL STUDS

FRAMING @ 2'-0" OC

10' - 0"

JOINT COVER PLATE

JOINT COVER PLATE

JOINT COVER PLATE

JOINT COVER PLATE

JOINT COVER PLATE

JOINT COVER PLATE

NEW ADDITIONEXISTING

A-604B

A-604B

• TPO ROOFING MEMBRANE

• 1/2" COVER BOARD

• R-30ci RIGID INSULATION

SLOPE TO DRAIN

• VAPOR RETARDER

• 1/2" PLYWOOD SHEATHING

• 2 1/2" METAL DECK

EXTERIOR WALL:

• 2" METAL PANEL SYSTEM

• R-10ci RIGID INSULATION

• WRB

• 5/8" EXTERIOR GYPSUM BOARD

• 3 5/8" METAL STUDS @ 16" OC

• R-15 BATT INSULATION

• VAPOR RETARDER

• 5/8" TYPE X GYPSUM BOARD

15 M

1' - 2" 4"

T Y

P

NEW LINTEL,

TYP

NEW LINTEL,

TYP

A-604C

M

IN

SPRAY APPLY FIREPROOFING @

ALL STRUCTURAL MEMBERS,

TYP

CABLE TRAY, TYP

LIGHT FIXTURE

SHOWN AREA

PROJECT

NORTH

BLDG 15

TOWER

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

EHRM INFRASTRUCTURE

UPGRADES - KANSAS CITY, MO

KANSAS CITY VAMC 4801 LINWOOD BLVD KANSAS CITY, MO 64128

589-21-700

SPEES DESIGN BUILD

625 1ST AVE, STE 301

SEATTLE, WA 98104

(206) 590-2118

RAY SPEES 15AE-103

BLDG 15 TOWER - SECTIONS

MA/EM DD

100% CONSTRUCTION

DOCUMENTS

06/19/2023

Revisions: Date:

1/4" = 1'-0"

BLDG 15 SECTION THRU NORTH

1/4" = 1'-0"

BLDG 15 SECTION THRU WEST

LEGEND

GENERAL NOTES

KEYNOTES (THIS SHEET ONLY)

KEY PLAN

07/19/2023ADDENDUM #1

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 203

KENT, WA 98032

(206) 590-2118

RAY SPEES

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 203

KENT, WA 98032

(206) 590-2118

SUB-BASEMENT

922' - 0"

15.J15.K

FIRST FLOOR

946' - 0"

SECOND FLOOR

958' - 0"

THIRD FLOOR

969' - 6 1/2"

SEVENTH FLOOR

1015' - 8 1/2"

EIGHTH FLOOR

1027' - 3"

BLDG 15 BASEMENT

929' - 2"

15.L

Bldg 15 T.O. Low Roof

1038' - 7 1/2"

15AE-103

15 M

123 SF

OFFICE

F-100A

168 SF

TR

F1-000

168 SF

TR

C1-12

168 SF

TR

F3-000

168 SF

TR

F6-000

168 SF

TR

F7-000

93 SF

CELL CULTURE

ROOM

F2-102A

95 SF

CELL CULTURE

ROOM

F3-102A

168 SF

TR

F8-000

3/4" THK PRESSURE

TREATED PLYWOOD

LINER

LUCABOND SOFFIT

OVER 7/8" HAT

CHANNEL @ 2'-0" OC

5/8" GWB SHEATHING

OVER 2 1/2" METAL STUDS

FRAMING @ 2'-0" OC

JOINT COVER PLATE

JOINT COVER PLATE

JOINT COVER PLATE

NEW ADDITION EXISTING

• TPO ROOFING MEMBRANE

• 1/2" COVER BOARD

• R-30ci RIGID INSULATION

SLOPE TO DRAIN

• VAPOR RETARDER

• 1/2" PLYWOOD SHEATHING

• 2 1/2" METAL DECK

EXTERIOR WALL:

• 2" METAL PANEL SYSTEM

• R-10ci RIGID INSULATION

• WRB

• 5/8" EXTERIOR GYPSUM BOARD

• 3 5/8" METAL STUDS @ 16" OC

• R-15 BATT INSULATION

• VAPOR RETARDER

• 5/8" TYPE X GYPSUM BOARD

A-604C

JOINT COVER PLATE

DATA RACK, TYP

CABLE TRAY, TYP

E1 E1

FIRE RESISTANT

PLYWOOD LINER, TYP

SHAFT WALL BEYOND

LUCABOND COLUMN

WRAP, TYP

V E

R

IF

Y

ELECT

PANEL, TYP

SPRAY APPLY

FIREPROOFING @ ALL

STRUCTURAL MEMBERS, TYP

SUB-BASEMENT

922' - 0"

15.115.2

FIRST FLOOR

946' - 0"

SECOND FLOOR

958' - 0"

THIRD FLOOR

969' - 6 1/2"

SEVENTH FLOOR

1015' - 8 1/2"

EIGHTH FLOOR

1027' - 3"

BLDG 15 BASEMENT

929' - 2"

Bldg 15 T.O. Low Roof

1038' - 7 1/2"

15AE-103

15AE-104

15.1.2 15.1.1

168 SF

TR

F8-000

168 SF

TR

F7-000

168 SF

TR

F6-000

168 SF

TR

F3-000

168 SF

TR

C1-12

168 SF

TR

F1-000

• TPO ROOFING MEMBRANE

• 1/2" COVER BOARD

• R-30ci RIGID INSULATION

SLOPE TO DRAIN

• VAPOR RETARDER

• 1/2" PLYWOOD SHEATHING

• 2 1/2" METAL DECK

COLUMN WRAP WITH

4" RECESSED BASE

AND TOP

3/4" THK PRESSURE

TREATED PLYWOOD

LINER, TYP

LUCABOND SOFFIT

OVER 7/8" HAT

CHANNEL @ 2'-0" OC

5/8" GWB SHEATHING

OVER 2 1/2" METAL STUDS

FRAMING @ 2'-0" OC

JOINT FILLER

JOINT COVER PLATE

NEW ADDITION

EXISTING

JOINT FILLER

JOINT FILLER

JOINT FILLER

JOINT FILLER

EXTERIOR WALL:

• 2" METAL PANEL SYSTEM

• R-10ci RIGID INSULATION

• WRB

• 5/8" EXTERIOR GYPSUM BOARD

• 3 5/8" METAL STUDS @ 16" OC

• R-15 BATT INSULATION

• VAPOR RETARDER

• 5/8" TYPE X GYPSUM BOARD

M20 J1

SHAFT WALL, TYP

J1

M20

E1

CABLE TRAY

DATA RACK

SHOWN AREA

PROJECT

NORTH

BLDG 15

TOWER

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

EHRM INFRASTRUCTURE

UPGRADES - KANSAS CITY, MO

KANSAS CITY VAMC 4801 LINWOOD BLVD KANSAS CITY, MO 64128

589-21-700

SPEES DESIGN BUILD

625 1ST AVE, STE 301

SEATTLE, WA 98104

(206) 590-2118

RAY SPEES 15AE-104

BLDG 15 TOWER - SECTIONS

MA/EM DD

100% CONSTRUCTION

DOCUMENTS

06/19/2023

Revisions: Date:

1/4" = 1'-0"

BLDG 15 SECTION - THRU NORTH LOOKING EAST

1/4" = 1'-0"

BLDG 15 SECTION - LOOKING NORTH

LEGEND

GENERAL NOTES

KEYNOTES (THIS SHEET ONLY)

KEY PLAN

07/19/2023ADDENDUM #1

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 203

KENT, WA 98032

(206) 590-2118

RAY SPEES

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 203

KENT, WA 98032

(206) 590-2118

DN

SHOWN AREA

PROJECT

NORTH

15.C

15.D

15.E

15.F

15.G

15.H

15.J

15.K

15.4 15.115.215.3

15.B

15.L

1.21

ELEVATOR NO.

E10

ELEVATOR

LOBBY

EB-F

MECH. ROOM

FB-100B

MECH. ROOM

FB-100

MECH. ROOM

FB-100A

SECTION 1A:

CONTRACTOR TO COORDINATE

WITH VA FOR ROOM CLOSURES

AND AVAILABILITY TO COMPLETE

DATA WIRING IN THIS AREA

MECHANICAL

MB-243

TRANSFER

DUCT

MB-243A

SECTION 1B:

CONTRACTOR TO COORDINATE

WITH VA FOR ROOM CLOSURES

AND AVAILABILITY TO COMPLETE

DATA WIRING IN THIS AREA

ICRA CLASS II

ICRA CLASS III

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

EHRM INFRASTRUCTURE

UPGRADES - KANSAS CITY, MO

KANSAS CITY VAMC 4801 LINWOOD BLVD KANSAS CITY, MO 64128

589-21-700

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 203

KENT, WA 98032

(206) 590-2118

RAY SPEES 15AS100

BUILDING 15 - LEVEL 00 - PHASING

PLAN 15

MA/EM CO

100% CONSTRUCTION

DOCUMENTS

06/19/2023

LEGENDLEGEND

KEY PLAN

1" = 10'-0"

BUILDING 15 - LEVEL 00 - PHASING PLAN

PROJECT

NORTH

0' 5' 10' 20'

Revisions: Date:

GENERAL NOTES

DUST MITIGATION NOTES

1. FOR THOSE CLOSETS IDENTIFIED TO REMAIN IN PLACE AND

BE REMODELED, THE CONTRACTOR SHALL WORK CLOSELY

WITH THE COR AND OIT TO PROTECT ALL EQUIPMENT FROM

THE HAZARDOUS EFFECTS OF DUST AND DEBRIS THAT WILL

BE GENERATED FROM CONSTRUCTION ACTIVITIES. THE

CONTRACTOR SHALL PROVIDE A LIST OF THOSE SPACES

THAT MAY BE ADVERSELY AFFECTED BY CONSTRUCTION TO

THE COR PRIOR TO THE START OF ANY CONSTRUCTION

ACTIVITIES.

2. CONTRACTOR SHALL SUBMIT A PLAN OF ACTION TO

MITIGATE THE EFFECTS OF DUST, DIRT AND DEBRIS WHICH

MAY INCLUDE THE FOLLOWING: PLASTIC SHEETING, CLEAN

AIR RECIRCULATION, SHORT DURATION POWER OUTAGES,

OFF HOURS WORK, ADDITIONAL CLEANING OF THE AREA

AFFECTED, TEMPORARY RELOCATION WITHIN THE ROOM OF

EQUIPMENT.

3. THE TYPES OF EQUIPMENT THAT MAY NEED PROTECTION

FROM CONSTRUCTION ACTIVITIES INCLUDES BUT IS NOT

LIMITED TO: RACK MOUNTED SERVERS, ROUTERS AND

SWITCH GEAR, FIRE ALARM PANELS, ACCESS CONTROL

PANELS, NURSE CALL, CCTV, SMOKE DETECTORS AND FIBER

OPTIC ENCLOSURES.

4. THE CONTRACTOR SHALL CLEAN ALL AREAS AFTER EACH

WORK PERIOD WITH VACUUMS THAT HAVE HEPA FILTERS IN

PLACE TO MINIMIZE THE RECIRCULATION OF DUST AND DIRT.

CONTRACTOR SHALL ALSO WIPE DOWN EQUIPMENT WITH

CLEANING WIPES TO ASSURE ANY EXCESS DUST IS

REMOVED.

5. THE CONTRACTOR SHALL PROVIDE PORTABLE COOLING AS

REQUIRED FOR ANY TELECOM RACKS REMAINING IN PLACE

DURING CONSTRUCTION ACTIVITIES.

A/E:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 203

KENT, WA 98032

(206) 590-2118

86 of 512Page 86 of 518

PROJECT

NORTH

ICRA CLASS II

ICRA CLASS III

ICRA CLASS IV

TR

TR

FIRE EXTINGUISHER CLOSETFEC

FIRE EXTINGUISHERFE

1.21

1.D.1

15.C

15.D

15.E

15.F

15.G

15.H

15.5

15.4 15.3

15.B

15.A

MECH.

SPRINKLER

VALVES

F1-101

CLINIC

RESEARCH

F1-105

OFFICE

F1-108A

OFFICE

F1-107A

CLINIC

RESEARCH

F1-107

CLINIC

RESEARCH

F1-109

OFFICE

F1-110A

OFFICE

F1-111

WORK ROOM

F1-113

OFFICE

F1-112A

MECH. ROOM

F1-117

CONFERENCE

ROOM

F1-119

OFFICE

F1-122

OFFICE

F1-123

OFFICE

F1-125A

OFFICE

F1-125

OFFICE

F1-129

OFFICE

F1-130

OFFICE

F1-132

OFFICE

F1-131

LOCKER,

FEMALE

F1-127

H.A.C.

F1-151

TOILET

F1-127A

STAIRWELL

S14

ELEVATOR

E10

ELEVATOR

E9

STAIRWELL

S20

CORRIDOR

C1-12

VESTIBULE

C1-10C

WORK ROOM

F1-137

OFFICE

F-100A

TR

F1-000

OFFICE

F1-100B

CLINIC

RESEARCH

F1-100

CLINIC

RESEARCH

F1-104

CLINIC

RESEARCH

F1-108

CLINIC

RESEARCH

F1-110

OFFICE

F1-112

OFFICE

F1-114

MECH. ROOM

F1-118

WORK ROOM

F1-120

15.2 15.1

15.J

15.K

15.L

CORRIDOR

C1-11

TR

PHASE 1: CONTRACTOR

TO COMPLETE THE WORK

OF THIS TR AND

ASSOCIATED DATA DROPS.

COMPLETE ONE

SECTION AT A TIME AS

DIRECTED TO COR.

SECTION 1A:

CONTRACTOR TO COORDINATE

WITH VA FOR ROOM

CLOSURES AND AVAILABILITY

TO COMPLETE DATA WIRING IN

THIS AREA

SECTION 1B:

CONTRACTOR TO COORDINATE

WITH VA FOR ROOM

CLOSURES AND AVAILABILITY

TO COMPLETE DATA WIRING IN

THIS AREA

15.1.2 15.1.1

15.M

FEC

FE

FEC

FEC

FAP

R 75' - 0"

LOBBY

C1-10B

DATA

M1-???

STORAGE

M1-209

STORAGE

M1-211

STORAGE

F1-153

FEC/FE REQUIRED WITHIN

75' RADIUS AROUND TR/TE

F1-000

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

EHRM INFRASTRUCTURE

UPGRADES - KANSAS CITY, MO

KANSAS CITY VAMC 4801 LINWOOD BLVD KANSAS CITY, MO 64128

589-21-700

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 203

KENT, WA 98032

(206) 590-2118

RAY SPEES 15AS101

BUILDING 15 - LEVEL 01 - PHASING

PLAN 15

MA/EM CO

100% CONSTRUCTION

DOCUMENTS

06/19/2023

LEGENDLEGEND

KEY PLAN

PROJECT

NORTH

1" = 10'-0"

BUILDING 15 - LEVEL 01 - PHASING PLAN

0' 5' 10' 20'

Revisions: Date:

GENERAL NOTES

DUST MITIGATION NOTES

1. FOR THOSE CLOSETS IDENTIFIED TO REMAIN IN PLACE AND

BE REMODELED, THE CONTRACTOR SHALL WORK CLOSELY

WITH THE COR AND OIT TO PROTECT ALL EQUIPMENT FROM

THE HAZARDOUS EFFECTS OF DUST AND DEBRIS THAT WILL

BE GENERATED FROM CONSTRUCTION ACTIVITIES. THE

CONTRACTOR SHALL PROVIDE A LIST OF THOSE SPACES

THAT MAY BE ADVERSELY AFFECTED BY CONSTRUCTION TO

THE COR PRIOR TO THE START OF ANY CONSTRUCTION

ACTIVITIES.

2. CONTRACTOR SHALL SUBMIT A PLAN OF ACTION TO

MITIGATE THE EFFECTS OF DUST, DIRT AND DEBRIS WHICH

MAY INCLUDE THE FOLLOWING: PLASTIC SHEETING, CLEAN

AIR RECIRCULATION, SHORT DURATION POWER OUTAGES,

OFF HOURS WORK, ADDITIONAL CLEANING OF THE AREA

AFFECTED, TEMPORARY RELOCATION WITHIN THE ROOM OF

EQUIPMENT.

3. THE TYPES OF EQUIPMENT THAT MAY NEED PROTECTION

FROM CONSTRUCTION ACTIVITIES INCLUDES BUT IS NOT

LIMITED TO: RACK MOUNTED SERVERS, ROUTERS AND

SWITCH GEAR, FIRE ALARM PANELS, ACCESS CONTROL

PANELS, NURSE CALL, CCTV, SMOKE DETECTORS AND FIBER

OPTIC ENCLOSURES.

4. THE CONTRACTOR SHALL CLEAN ALL AREAS AFTER EACH

WORK PERIOD WITH VACUUMS THAT HAVE HEPA FILTERS IN

PLACE TO MINIMIZE THE RECIRCULATION OF DUST AND DIRT.

CONTRACTOR SHALL ALSO WIPE DOWN EQUIPMENT WITH

CLEANING WIPES TO ASSURE ANY EXCESS DUST IS

REMOVED.

5. THE CONTRACTOR SHALL PROVIDE PORTABLE COOLING AS

REQUIRED FOR ANY TELECOM RACKS REMAINING IN PLACE

DURING CONSTRUCTION ACTIVITIES.

A/E:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 203

KENT, WA 98032

(206) 590-2118

87 of 512Page 87 of 518

NORTH

ICRA CLASS II

ICRA CLASS III

ICRA CLASS IV

TR

TR

FIRE EXTINGUISHER CLOSETFEC

FIRE EXTINGUISHERFE

1.21

15.C

15.D

15.E

15.F

15.G

15.H

15.5

15.4 15.3

15.B

15.A

STAIRWELL NO.

S14

379 SF

MECH. ROOM

F2-117

114 SF

LAB

F2-121

370 SF

MECHM ROOM

F2-116

75 SF

ELEVATOR NO.

E9

79 SF

ELEVATOR NO.

E10

13 SF

CLOSET

F2-101 92 SF

CELL CULTURE

ROOM

F2-102A

119 SF

CELL CULTURE

ROOM

F2-105A

91 SF

MICROSCOPY

F2-105B

25 SF

EMERGENCY

SHOWER

F2-103

742 SF

LAB

F2-105

12 SF

ICE MACHINE

F2-106

138 SF

WORKSTATION

F2-105C

134 SF

STORAGE

F2-107

120 SF

WORKSTATION

F2-102C

308 SF

LAB

EQUIPMENT

F2-110

111 SF

WORKSTATION

F2-126C

123 SF

BD FACSAria

FUSION ROOM

F2-126D

799 SF

LAB

F2-126

79 SF

MICROSCOPY

F2-126B

102 SF

CELL CULTURE

ROOM

F2-126A

58 SF

RESTROOM

F2-126E

35 SF

CARTS

F2-127B

140 SF

RECEPTION

F2-131A

112 SF

BREAK ROOM

F2-127

254 SF

CONFERENCE

ROOM

F2-125

142 SF

SHARED

STORAGE

F2-123

293 SF

COLLABORATION

ZONE

F2-131

297 SF

CORRIDOR

C2-12

189 SF

TR

F2-000

15.2 15.1

15.J

15.K

15.L

TR

PHASE 1: CONTRACTOR

TO COMPLETE THE WORK

OF THIS TR AND

ASSOCIATED DATA DROPS.

COMPLETE ONE

SECTION AT A TIME AS

DIRECTED TO COR.

SECTION 1A:

CONTRACTOR TO COORDINATE

WITH VA FOR ROOM

CLOSURES AND AVAILABILITY

TO COMPLETE DATA WIRING IN

THIS AREA

SECTION 1B:

CONTRACTOR TO COORDINATE

WITH VA FOR ROOM

CLOSURES AND AVAILABILITY

TO COMPLETE DATA WIRING IN

THIS AREA

815 SF

F2-002

R 75' - 0"

FAP

15.M

EQPT RM #2

M2-143

MRI

M2-145

MRI ANTE ROOM

M2-120

TOILET

M2-142TOILET

M2-144

CORRIDOR

C2-16

DRESS'G 4

M2-140

DRESS'G 2

M2-138

CONSULT

M2-136

CORRIDOR

C2-15

DRESS'G 1

M2-137

DRESS'G 3

M2-139

EMS CLOSET

M2-141

TOILET

M2-150

TOILET

M2-158A

ANTE

M2-157

STORAGE

M2-135

CORRIDOR

C2-10

FEC/FE REQUIRED WITHIN

75' RADIUS AROUND TR/TE

15.1.2

F2-000

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

EHRM INFRASTRUCTURE

UPGRADES - KANSAS CITY, MO

KANSAS CITY VAMC 4801 LINWOOD BLVD KANSAS CITY, MO 64128

589-21-700

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 203

KENT, WA 98032

(206) 590-2118

RAY SPEES 15AS102

BUILDING 15 - LEVEL 02 - PHASING

PLAN 15

MA/EM CO

100% CONSTRUCTION

DOCUMENTS

06/19/2023

LEGENDLEGEND

KEY PLAN

PROJECT

NORTH

0' 5' 10' 20'1" = 10'-0"

BUILDING 15 - LEVEL 02 - PHASING PLAN

Revisions: Date:

GENERAL NOTES

DUST MITIGATION NOTES

1. FOR THOSE CLOSETS IDENTIFIED TO REMAIN IN PLACE AND

BE REMODELED, THE CONTRACTOR SHALL WORK CLOSELY

WITH THE COR AND OIT TO PROTECT ALL EQUIPMENT FROM

THE HAZARDOUS EFFECTS OF DUST AND DEBRIS THAT WILL

BE GENERATED FROM CONSTRUCTION ACTIVITIES. THE

CONTRACTOR SHALL PROVIDE A LIST OF THOSE SPACES

THAT MAY BE ADVERSELY AFFECTED BY CONSTRUCTION TO

THE COR PRIOR TO THE START OF ANY CONSTRUCTION

ACTIVITIES.

2. CONTRACTOR SHALL SUBMIT A PLAN OF ACTION TO

MITIGATE THE EFFECTS OF DUST, DIRT AND DEBRIS WHICH

MAY INCLUDE THE FOLLOWING: PLASTIC SHEETING, CLEAN

AIR RECIRCULATION, SHORT DURATION POWER OUTAGES,

OFF HOURS WORK, ADDITIONAL CLEANING OF THE AREA

AFFECTED, TEMPORARY RELOCATION WITHIN THE ROOM OF

EQUIPMENT.

3. THE TYPES OF EQUIPMENT THAT MAY NEED PROTECTION

FROM CONSTRUCTION ACTIVITIES INCLUDES BUT IS NOT

LIMITED TO: RACK MOUNTED SERVERS, ROUTERS AND

SWITCH GEAR, FIRE ALARM PANELS, ACCESS CONTROL

PANELS, NURSE CALL, CCTV, SMOKE DETECTORS AND FIBER

OPTIC ENCLOSURES.

4. THE CONTRACTOR SHALL CLEAN ALL AREAS AFTER EACH

WORK PERIOD WITH VACUUMS THAT HAVE HEPA FILTERS IN

PLACE TO MINIMIZE THE RECIRCULATION OF DUST AND DIRT.

CONTRACTOR SHALL ALSO WIPE DOWN EQUIPMENT WITH

CLEANING WIPES TO ASSURE ANY EXCESS DUST IS

REMOVED.

5. THE CONTRACTOR SHALL PROVIDE PORTABLE COOLING AS

REQUIRED FOR ANY TELECOM RACKS REMAINING IN PLACE

DURING CONSTRUCTION ACTIVITIES.

A/E:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 203

KENT, WA 98032

(206) 590-2118

88 of 512Page 88 of 518

NORTH

ICRA CLASS II

ICRA CLASS III

ICRA CLASS IV

TR

TR

FIRE EXTINGUISHER CLOSETFEC

FIRE EXTINGUISHERFE

F3-000

1.F

1.J

1.21

1.D.1

15.C

15.D

15.E

15.F

15.G

15.H

15.5

15.4

15.B

15.A

15.1

93 SF

CELL CULTURE

ROOM

F3-102A

80 SF

MICROSCOPY

F3-102B

788 SF

LAB

F3-102

120 SF

WORKSTATION

F3-102C

309 SF

LAB

EQUIPMENT

F3-110

369 SF

MECH. ROOM

F3-116

368 SF

MECH. ROOM

F3-117

163 SF

STERILIZER

F3-121

123 SF

SPECIAL

EQUIPMENT

F3-120

112 SF

WORKSTATION

F3-126A

784 SF

LAB

F3-126260 SF

CONFERENCE

ROOM

F3-125

112 SF

BREAK ROOM

F3-127

34 SF

CARTS

F3-127B

58 SF

RESTROOM

F3-127A

79 SF

MICROSCOPY

F3-126C

102 SF

CELL CULTURE

ROOM

F3-126B

141 SF

CORRIDOR

C3-11

189 SF

TR

F3-000

127 SF

STAIRWELL NO.

S14

119 SF

CELL CULTURE

ROOM

F3-105A

89 SF

MICROSCOPY

F3-105B

161 SF

CORRIDOR

C3-11B

23 SF

EMERGENCY

SHOWER

F3-103

653 SF

LAB

F3-105

134 SF

STORAGE

F3-107

137 SF

WORKSTATION

F3-105C

12 SF

ICE MACHINE

F3-106

391 SF

CORRIDOR

C3-12

146 SF

RECEPTION

F3-131A

219 SF

COLLABORATION

ZONE

F3-131

13 SF

EMERGENCY

SHOWER

F3-126E

13 SF

CLOSET

F3-101

158 SF

STAIRWELL NO.

S20

253 SF

CORRIDOR

C3-10

77 SF

ELEVATOR

15.3 15.2

15.J

15.K

15.L

TR

PHASE 1: CONTRACTOR

TO COMPLETE THE WORK

OF THIS TR AND

ASSOCIATED DATA DROPS.

COMPLETE ONE

SECTION AT A TIME AS

DIRECTED TO COR.

SECTION 1A:

CONTRACTOR TO COORDINATE

WITH VA FOR ROOM

CLOSURES AND AVAILABILITY

TO COMPLETE DATA WIRING IN

THIS AREA.

SECTION 1B:

CONTRACTOR TO COORDINATE

WITH VA FOR ROOM

CLOSURES AND AVAILABILITY

TO COMPLETE DATA WIRING IN

THIS AREA

R

5'

0"

FAP

15.M

FEC/FE REQUIRED WITHIN

75' RADIUS AROUND TR/TE

15.1.2

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

EHRM INFRASTRUCTURE

UPGRADES - KANSAS CITY, MO

KANSAS CITY VAMC 4801 LINWOOD BLVD KANSAS CITY, MO 64128

589-21-700

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 203

KENT, WA 98032

(206) 590-2118

RAY SPEES 15AS103

BUILDING 15 - LEVEL 03 - PHASING

PLAN 15

MA/EM CO

100% CONSTRUCTION

DOCUMENTS

06/19/2023

LEGENDLEGEND

KEY PLAN

PROJECT

NORTH

0' 5' 10' 20'1" = 10'-0"

BUILDING 15 - LEVEL 03 - PHASING PLAN

Revisions: Date:

GENERAL NOTES

DUST MITIGATION NOTES

1. FOR THOSE CLOSETS IDENTIFIED TO REMAIN IN PLACE AND

BE REMODELED, THE CONTRACTOR SHALL WORK CLOSELY

WITH THE COR AND OIT TO PROTECT ALL EQUIPMENT FROM

THE HAZARDOUS EFFECTS OF DUST AND DEBRIS THAT WILL

BE GENERATED FROM CONSTRUCTION ACTIVITIES. THE

CONTRACTOR SHALL PROVIDE A LIST OF THOSE SPACES

THAT MAY BE ADVERSELY AFFECTED BY CONSTRUCTION TO

THE COR PRIOR TO THE START OF ANY CONSTRUCTION

ACTIVITIES.

2. CONTRACTOR SHALL SUBMIT A PLAN OF ACTION TO

MITIGATE THE EFFECTS OF DUST, DIRT AND DEBRIS WHICH

MAY INCLUDE THE FOLLOWING: PLASTIC SHEETING, CLEAN

AIR RECIRCULATION, SHORT DURATION POWER OUTAGES,

OFF HOURS WORK, ADDITIONAL CLEANING OF THE AREA

AFFECTED, TEMPORARY RELOCATION WITHIN THE ROOM OF

EQUIPMENT.

3. THE TYPES OF EQUIPMENT THAT MAY NEED PROTECTION

FROM CONSTRUCTION ACTIVITIES INCLUDES BUT IS NOT

LIMITED TO: RACK MOUNTED SERVERS, ROUTERS AND

SWITCH GEAR, FIRE ALARM PANELS, ACCESS CONTROL

PANELS, NURSE CALL, CCTV, SMOKE DETECTORS AND FIBER

OPTIC ENCLOSURES.

4. THE CONTRACTOR SHALL CLEAN ALL AREAS AFTER EACH

WORK PERIOD WITH VACUUMS THAT HAVE HEPA FILTERS IN

PLACE TO MINIMIZE THE RECIRCULATION OF DUST AND DIRT.

CONTRACTOR SHALL ALSO WIPE DOWN EQUIPMENT WITH

CLEANING WIPES TO ASSURE ANY EXCESS DUST IS

REMOVED.

5. THE CONTRACTOR SHALL PROVIDE PORTABLE COOLING AS

REQUIRED FOR ANY TELECOM RACKS REMAINING IN PLACE

DURING CONSTRUCTION ACTIVITIES.

A/E:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 203

KENT, WA 98032

(206) 590-2118

89 of 512Page 89 of 518

NORTH

ICRA CLASS II

ICRA CLASS III

ICRA CLASS IV

TR

TR

FIRE EXTINGUISHER CLOSETFEC

FIRE EXTINGUISHERFE

F4-000

1.F

1.J

1.21

1.D.1

15.C

15.D

15.E

15.F

15.G

15.H

15.J

15.K

15.5

15.4 15.115.215.3

15.B

15.A

15.L

OFFICE, CHIEF

M4-202

OFFICE

M4-201

CORRIDOR

C4-20

STORAGE

F4-100

MECH.

SPRINKLER

VALVES

F4-101

DARKROOM

F4-103

LAB

F4-104

LAB

F4-105

LAB

F4-108

COLD ROOM

F4-109

LAB

F4-110

COLD ROOM

F4-111

MECH. ROOM

F4-114

MECH. ROOM

F4-115

LAB

F4-117

LAB

F4-120

LAB

F4-125

LAB

F4-124

OFFICE

F4-127

OFFICE

F4-130

CONFERENCE

ROOM

F4-131

OFFICE

F4-130A

OFFICE

F4-130B

JAN. CLOSET

F4-151

STAFF LOCKER,

MALE

F4-153

CORRIDOR

C4-11

CORRIDOR

C4-12

ELEVATOR NO.

E10

ELEVATOR NO.

E9

STAIRWELL NO.

S20

STAIRWELL NO.

S14

RAD

CORRIDOR

C4-10

FAP

TR

F4-000

TR

PHASE 1: CONTRACTOR

TO COMPLETE THE WORK

OF THIS TR AND

ASSOCIATED DATA DROPS.

COMPLETE ONE

SECTION AT A TIME AS

DIRECTED TO COR.

SECTION 1A:

CONTRACTOR TO COORDINATE

WITH VA FOR ROOM

CLOSURES AND AVAILABILITY

TO COMPLETE DATA WIRING IN

THIS AREA.

SECTION 1B:

CONTRACTOR TO COORDINATE

WITH VA FOR ROOM

CLOSURES AND AVAILABILITY

TO COMPLETE DATA WIRING IN

THIS AREA.

R

5'

0"

15.M

FEC/FE REQUIRED WITHIN 75'

RADIUS AROUND TR/TE

15.1.2

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

EHRM INFRASTRUCTURE

UPGRADES - KANSAS CITY, MO

KANSAS CITY VAMC 4801 LINWOOD BLVD KANSAS CITY, MO 64128

589-21-700

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 203

KENT, WA 98032

(206) 590-2118

RAY SPEES 15AS104

BUILDING 15 - LEVEL 04 - PHASING

PLAN 15

MA/EM CO

100% CONSTRUCTION

DOCUMENTS

06/19/2023

LEGENDLEGEND

KEY PLAN

1" = 10'-0"

BUILDING 15 - LEVEL 04 - PHASING PLAN

PROJECT

NORTH

0' 5' 10' 20'

Revisions: Date:

GENERAL NOTES

DUST MITIGATION NOTES

1. FOR THOSE CLOSETS IDENTIFIED TO REMAIN IN PLACE AND

BE REMODELED, THE CONTRACTOR SHALL WORK CLOSELY

WITH THE COR AND OIT TO PROTECT ALL EQUIPMENT FROM

THE HAZARDOUS EFFECTS OF DUST AND DEBRIS THAT WILL

BE GENERATED FROM CONSTRUCTION ACTIVITIES. THE

CONTRACTOR SHALL PROVIDE A LIST OF THOSE SPACES

THAT MAY BE ADVERSELY AFFECTED BY CONSTRUCTION TO

THE COR PRIOR TO THE START OF ANY CONSTRUCTION

ACTIVITIES.

2. CONTRACTOR SHALL SUBMIT A PLAN OF ACTION TO

MITIGATE THE EFFECTS OF DUST, DIRT AND DEBRIS WHICH

MAY INCLUDE THE FOLLOWING: PLASTIC SHEETING, CLEAN

AIR RECIRCULATION, SHORT DURATION POWER OUTAGES,

OFF HOURS WORK, ADDITIONAL CLEANING OF THE AREA

AFFECTED, TEMPORARY RELOCATION WITHIN THE ROOM OF

EQUIPMENT.

3. THE TYPES OF EQUIPMENT THAT MAY NEED PROTECTION

FROM CONSTRUCTION ACTIVITIES INCLUDES BUT IS NOT

LIMITED TO: RACK MOUNTED SERVERS, ROUTERS AND

SWITCH GEAR, FIRE ALARM PANELS, ACCESS CONTROL

PANELS, NURSE CALL, CCTV, SMOKE DETECTORS AND FIBER

OPTIC ENCLOSURES.

4. THE CONTRACTOR SHALL CLEAN ALL AREAS AFTER EACH

WORK PERIOD WITH VACUUMS THAT HAVE HEPA FILTERS IN

PLACE TO MINIMIZE THE RECIRCULATION OF DUST AND DIRT.

CONTRACTOR SHALL ALSO WIPE DOWN EQUIPMENT WITH

CLEANING WIPES TO ASSURE ANY EXCESS DUST IS

REMOVED.

5. THE CONTRACTOR SHALL PROVIDE PORTABLE COOLING AS

REQUIRED FOR ANY TELECOM RACKS REMAINING IN PLACE

DURING CONSTRUCTION ACTIVITIES.

A/E:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 203

KENT, WA 98032

(206) 590-2118

90 of 512Page 90 of 518

FAS

1.21

1.D.1

15.C

15.D

15.E

15.F

15.G

15.H

15.J

15.K

15.5

15.4 15.115.215.3

15.B

15.A

15.L

OFFICE

F5-100

MECH.

SPRINKLER

VALVES

F5-101

CLINICAL

RESEARCH

F5-103

OFFICE

F5-105

MOTHER'S

ROOM

F5-106

ELEVATOR NO.

E10

STAIRWELL NO.

S14

CORRIDOR

C5-11

CLINICAL

RESEARCH

F5-108

CLINICAL

RESEARCH

F5-110

CLINICAL

RESEARCH

F5-109

CHEMICAL LAB

F5-112

ELECTRICS

SHOP

F5-111

MECH. ROOM

F5-116

MECH. ROOM

F5-117

LAB

F5-120

LAB / OFFICE

F5-121

CLINICAL

RESEARCH

F5-123

OFFICE

F5-124

OFFICE

F5-125

OFFICE

F5-125A

OFFICE

F5-126

CLINICAL

RESEARCH

F5-130

CORRIDOR

C5-12

ELEVATOR NO.

E9

STAIRWELL NO.

S20

CLINICAL

RESEARCH

F5-151

JAN. CLOSET

F5-153

TOILET, FEMALE

F5-155

63 SF

F5-106A

TR

F5-000 TR

PHASE 1: CONTRACTOR

TO COMPLETE THE WORK

OF THIS TR AND

ASSOCIATED DATA DROPS.

COMPLETE ONE

SECTION AT A TIME AS

DIRECTED TO COR.

SECTION 1A:

CONTRACTOR TO COORDINATE

WITH VA FOR ROOM

CLOSURES AND AVAILABILITY

TO COMPLETE DATA WIRING IN

THIS AREA

SECTION 1B:

CONTRACTOR TO COORDINATE

WITH VA FOR ROOM

CLOSURES AND AVAILABILITY

TO COMPLETE DATA WIRING IN

THIS AREA

R

5'

0"

15.M

BIOMED

NETWORK

CLOSET

F5-157

FEC/FE REQUIRED WITHIN

75' RADIUS AROUND TR/TE

15.1.2

ICRA CLASS II

ICRA CLASS III

ICRA CLASS IV

TR

TR

FIRE EXTINGUISHER CLOSETFEC

FIRE EXTINGUISHERFE

F5-000

SHOWN AREA

PROJECT

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

EHRM INFRASTRUCTURE

UPGRADES - KANSAS CITY, MO

KANSAS CITY VAMC 4801 LINWOOD BLVD KANSAS CITY, MO 64128

589-21-700

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 203

KENT, WA 98032

(206) 590-2118

RAY SPEES 15AS105

BUILDING 15 - LEVEL 05 - PHASING

PLAN 15

MA/EM RB

100% CONSTRUCTION

DOCUMENTS

06/19/2023

LEGENDLEGEND

KEY PLAN

1" = 10'-0"

BUILDING 15 - LEVEL 05 - PHASING PLAN

0' 5' 10' 20'

PROJECT

NORTH

Revisions: Date:

GENERAL NOTES

DUST MITIGATION NOTES

1. FOR THOSE CLOSETS IDENTIFIED TO REMAIN IN PLACE AND

BE REMODELED, THE CONTRACTOR SHALL WORK CLOSELY

WITH THE COR AND OIT TO PROTECT ALL EQUIPMENT FROM

THE HAZARDOUS EFFECTS OF DUST AND DEBRIS THAT WILL

BE GENERATED FROM CONSTRUCTION ACTIVITIES. THE

CONTRACTOR SHALL PROVIDE A LIST OF THOSE SPACES

THAT MAY BE ADVERSELY AFFECTED BY CONSTRUCTION TO

THE COR PRIOR TO THE START OF ANY CONSTRUCTION

ACTIVITIES.

2. CONTRACTOR SHALL SUBMIT A PLAN OF ACTION TO

MITIGATE THE EFFECTS OF DUST, DIRT AND DEBRIS WHICH

MAY INCLUDE THE FOLLOWING: PLASTIC SHEETING, CLEAN

AIR RECIRCULATION, SHORT DURATION POWER OUTAGES,

OFF HOURS WORK, ADDITIONAL CLEANING OF THE AREA

AFFECTED, TEMPORARY RELOCATION WITHIN THE ROOM OF

EQUIPMENT.

3. THE TYPES OF EQUIPMENT THAT MAY NEED PROTECTION

FROM CONSTRUCTION ACTIVITIES INCLUDES BUT IS NOT

LIMITED TO: RACK MOUNTED SERVERS, ROUTERS AND

SWITCH GEAR, FIRE ALARM PANELS, ACCESS CONTROL

PANELS, NURSE CALL, CCTV, SMOKE DETECTORS AND FIBER

OPTIC ENCLOSURES.

4. THE CONTRACTOR SHALL CLEAN ALL AREAS AFTER EACH

WORK PERIOD WITH VACUUMS THAT HAVE HEPA FILTERS IN

PLACE TO MINIMIZE THE RECIRCULATION OF DUST AND DIRT.

CONTRACTOR SHALL ALSO WIPE DOWN EQUIPMENT WITH

CLEANING WIPES TO ASSURE ANY EXCESS DUST IS

REMOVED.

5. THE CONTRACTOR SHALL PROVIDE PORTABLE COOLING AS

REQUIRED FOR ANY TELECOM RACKS REMAINING IN PLACE

DURING CONSTRUCTION ACTIVITIES.

A/E:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 203

KENT, WA 98032

(206) 590-2118

91 of 512Page 91 of 518

ICRA CLASS II

ICRA CLASS III

ICRA CLASS IV

TR

TR

FIRE EXTINGUISHER CLOSETFEC

FIRE EXTINGUISHERFE

1.F

1.J

1.21

1.D.1

1.E.1

15.C

15.D

15.E

15.F

15.G

15.H

15.J

15.K

15.5

15.4 15.115.215.3

15.B

15.A

15.L

57 SF

TOILET, MALE

F6-155

ELEVATOR NO.

E10

STAIRWELL NO.

S14

MECH.

SPRINKLER

VALVES

F6-101

LAB

F6-100

BIOMED

STORAGE

F6-103

BIOMED

STORAGE

F6-105

BIOMED

STORAGE

F6-107

STORAGE

F6-109

BIOMED LAB

F6-106

POLICE DEPT.

F6-111

OFFICE

F6-114

OFFICE

F6-114A

MECH. ROOM

F6-119

MECH. ROOM

F6-118

MACHINE ROOM

F6-123

BIOMED

ENGINEERING

F6-120

BIOMED

ENGINEERING

F6-130

MACHINE ROOM

F6-123A

STORAGE

F6-151

CORRIDOR

F6-112

CORRIDOR

C6-11

CORRIDOR

C6-10

ELEVATOR NO.

E9

STAIRWELL NO.

S20

OFFICE

F6-129

98 SF

F6-123A

TR

PHASE 1: CONTRACTOR

TO COMPLETE THE WORK

OF THIS TR AND

ASSOCIATED DATA DROPS.

COMPLETE ONE

SECTION AT A TIME AS

DIRECTED TO COR.

SECTION 1A:

CONTRACTOR TO COORDINATE

WITH VA FOR ROOM

CLOSURES AND AVAILABILITY

TO COMPLETE DATA WIRING IN

THIS AREA

SECTION 1B:

CONTRACTOR TO COORDINATE

WITH VA FOR ROOM

CLOSURES AND AVAILABILITY

TO COMPLETE DATA WIRING IN

THIS AREA

CORRIDOR

94 SF

CORRIDOR

FAP

R

5'

0"

FAP

15.M

191 SF

CORRIDOR

F6-001

49 SF

TOILET, FEMALE

F6-002

FEC/FE REQUIRED WITHIN

75' RADIUS AROUND TR/TE

TR

F6-000

189 SF

15.1.2

F6-000

SHOWN AREA

PROJECT

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

EHRM INFRASTRUCTURE

UPGRADES - KANSAS CITY, MO

KANSAS CITY VAMC 4801 LINWOOD BLVD KANSAS CITY, MO 64128

589-21-700

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 203

KENT, WA 98032

(206) 590-2118

RAY SPEES 15AS106

BUILDING 15 - LEVEL 06 - PHASING

PLAN 15

MA/EM ML

100% CONSTRUCTION

DOCUMENTS

06/19/2023

LEGEND

1" = 10'-0"

BUILDING 15 - LEVEL 06 - PHASING PLAN

PROJECT

NORTH

0' 5' 10' 20'

KEY PLAN

Revisions: Date:

GENERAL NOTES

DUST MITIGATION NOTES

1. FOR THOSE CLOSETS IDENTIFIED TO REMAIN IN PLACE AND

BE REMODELED, THE CONTRACTOR SHALL WORK CLOSELY

WITH THE COR AND OIT TO PROTECT ALL EQUIPMENT FROM

THE HAZARDOUS EFFECTS OF DUST AND DEBRIS THAT WILL

BE GENERATED FROM CONSTRUCTION ACTIVITIES. THE

CONTRACTOR SHALL PROVIDE A LIST OF THOSE SPACES

THAT MAY BE ADVERSELY AFFECTED BY CONSTRUCTION TO

THE COR PRIOR TO THE START OF ANY CONSTRUCTION

ACTIVITIES.

2. CONTRACTOR SHALL SUBMIT A PLAN OF ACTION TO

MITIGATE THE EFFECTS OF DUST, DIRT AND DEBRIS WHICH

MAY INCLUDE THE FOLLOWING: PLASTIC SHEETING, CLEAN

AIR RECIRCULATION, SHORT DURATION POWER OUTAGES,

OFF HOURS WORK, ADDITIONAL CLEANING OF THE AREA

AFFECTED, TEMPORARY RELOCATION WITHIN THE ROOM OF

EQUIPMENT.

3. THE TYPES OF EQUIPMENT THAT MAY NEED PROTECTION

FROM CONSTRUCTION ACTIVITIES INCLUDES BUT IS NOT

LIMITED TO: RACK MOUNTED SERVERS, ROUTERS AND

SWITCH GEAR, FIRE ALARM PANELS, ACCESS CONTROL

PANELS, NURSE CALL, CCTV, SMOKE DETECTORS AND FIBER

OPTIC ENCLOSURES.

4. THE CONTRACTOR SHALL CLEAN ALL AREAS AFTER EACH

WORK PERIOD WITH VACUUMS THAT HAVE HEPA FILTERS IN

PLACE TO MINIMIZE THE RECIRCULATION OF DUST AND DIRT.

CONTRACTOR SHALL ALSO WIPE DOWN EQUIPMENT WITH

CLEANING WIPES TO ASSURE ANY EXCESS DUST IS

REMOVED.

5. THE CONTRACTOR SHALL PROVIDE PORTABLE COOLING AS

REQUIRED FOR ANY TELECOM RACKS REMAINING IN PLACE

DURING CONSTRUCTION ACTIVITIES.

A/E:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 203

KENT, WA 98032

(206) 590-2118

92 of 512Page 92 of 518

15.1

15.H

15.J

15.K

15.4 15.215.3

15.L

15.C

15.D

15.E

15.F

15.G

15.5

15.B

15.A

1.J

1.21

1.D.1

RAD

115 SF

OFFICE

F7-100

660 SF

CORRIDOR

C7-11

161 SF

STAIRWELL NO.

S20

77 SF

ELEVATOR NO.

E9

186 SF

CONFERENCE

ROOM

F7-104A

187 SF

CONFERENCE

ROOM

F7-104

204 SF

CANCER

REGISTRY

F7-103

97 SF

OFFICE

F7-106A

400 SF

WORKROOM

F7-110

99 SF

OFFICE

F7-115

369 SF

MECH. ROOM

F7-120

362 SF

MECH. ROOM

F7-121

190 SF

COMPUTER

TRAINING

F7-125

203 SF

OFFICE

F7-124

987 SF

CLASSROOM

F7-130

99 SF

TOILET

F7-149

27 SF

JAN. CLOSET

F7-153

525 SF

CORRIDOR

C7-10

287 SF

CORRIDOR

C7-12

134 SF

STAIRWELL NO.

S14

15 SF

MECH.

SPRINKLER

F7-101

482 SF

LOGISTICS

F7-109

84 SF

ELEVATOR NO.

E10

190 SF

OFFICE

F7-105

97 SF

OFFICE

F7-106

203 SF

OFFICE

F7-117

105 SF

TOILET, FEMALE

F7-151

94 SF

Room

F7-100E

93 SF

Room

F7-100F

27 SF

JAN. CLOSET

F7-153

TR

PHASE 1:

CONTRACTOR

TO COMPLETE THE WORK OF THIS TR

AND ASSOCIATED DATA DROPS.

COMPLETE ONE SECTION AT A TIME

AS DIRECTED TO COR.

SECTION 1A:

CONTRACTOR TO COORDINATE

WITH VA FOR ROOM

CLOSURES AND AVAILABILITY

TO COMPLETE DATA WIRING IN

THIS AREA

SECTION 1B:

CONTRACTOR TO COORDINATE

WITH VA FOR ROOM

CLOSURES AND AVAILABILITY

TO COMPLETE DATA WIRING IN

THIS AREA

407 SF

187 SF

15.M

TR

F7-000

R

5'

BIOMED

NETWORK

CLOSET

F7-157

TOILET, MALE

F7-155

FEC/FE REQUIRED WITHIN

75' RADIUS AROUND TR/TE

15.1.2

SHOWN AREA

PROJECT

NORTH

F7-000

ICRA CLASS II

ICRA CLASS III

ICRA CLASS IV

TR

TR

FIRE EXTINGUISHER CLOSETFEC

FIRE EXTINGUISHERFE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

EHRM INFRASTRUCTURE

UPGRADES - KANSAS CITY, MO

KANSAS CITY VAMC 4801 LINWOOD BLVD KANSAS CITY, MO 64128

589-21-700

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 203

KENT, WA 98032

(206) 590-2118

RAY SPEES 15AS107

BUILDING 15 - LEVEL 07 - PHASING

PLAN 15

MA/EM JC

100% CONSTRUCTION

DOCUMENTS

06/19/2023

1" = 10'-0"

BUILDING 15 - LEVEL 07 - PHASING PLAN

LEGENDLEGEND

KEY PLAN

PROJECT

NORTH

0' 5' 10' 20'

Revisions: Date:

GENERAL NOTES

DUST MITIGATION NOTES

1. FOR THOSE CLOSETS IDENTIFIED TO REMAIN IN PLACE AND

BE REMODELED, THE CONTRACTOR SHALL WORK CLOSELY

WITH THE COR AND OIT TO PROTECT ALL EQUIPMENT FROM

THE HAZARDOUS EFFECTS OF DUST AND DEBRIS THAT WILL

BE GENERATED FROM CONSTRUCTION ACTIVITIES. THE

CONTRACTOR SHALL PROVIDE A LIST OF THOSE SPACES

THAT MAY BE ADVERSELY AFFECTED BY CONSTRUCTION TO

THE COR PRIOR TO THE START OF ANY CONSTRUCTION

ACTIVITIES.

2. CONTRACTOR SHALL SUBMIT A PLAN OF ACTION TO

MITIGATE THE EFFECTS OF DUST, DIRT AND DEBRIS WHICH

MAY INCLUDE THE FOLLOWING: PLASTIC SHEETING, CLEAN

AIR RECIRCULATION, SHORT DURATION POWER OUTAGES,

OFF HOURS WORK, ADDITIONAL CLEANING OF THE AREA

AFFECTED, TEMPORARY RELOCATION WITHIN THE ROOM OF

EQUIPMENT.

3. THE TYPES OF EQUIPMENT THAT MAY NEED PROTECTION

FROM CONSTRUCTION ACTIVITIES INCLUDES BUT IS NOT

LIMITED TO: RACK MOUNTED SERVERS, ROUTERS AND

SWITCH GEAR, FIRE ALARM PANELS, ACCESS CONTROL

PANELS, NURSE CALL, CCTV, SMOKE DETECTORS AND FIBER

OPTIC ENCLOSURES.

4. THE CONTRACTOR SHALL CLEAN ALL AREAS AFTER EACH

WORK PERIOD WITH VACUUMS THAT HAVE HEPA FILTERS IN

PLACE TO MINIMIZE THE RECIRCULATION OF DUST AND DIRT.

CONTRACTOR SHALL ALSO WIPE DOWN EQUIPMENT WITH

CLEANING WIPES TO ASSURE ANY EXCESS DUST IS

REMOVED.

5. THE CONTRACTOR SHALL PROVIDE PORTABLE COOLING AS

REQUIRED FOR ANY TELECOM RACKS REMAINING IN PLACE

DURING CONSTRUCTION ACTIVITIES.

A/E:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 203

KENT, WA 98032

(206) 590-2118

93 of 512Page 93 of 518

NORTH

15.B.8

15.C

15.D

15.E

15.F

15.G

15.H

15.J

15.K

15.4 15.115.215.3

15.B

15.A

15.L

1.21

ELEVATOR NO.

E10

WORK ROOM

F8-100

STAIRWELL NO.

S14

OFFICE

F8-105

OFFICE

F8-106

MEDICAL

LIBRARY

F8-120

MECH. ROOM

F8-123

MECH. ROOM

F8-122

LARGE FORMAT

PRINTING

F8-124

OFFICE

F8-126

OFFICE

F8-128

CLASSROOM

F8-129

OFFICE

F8-131

COPY CENTER

F8-132

OFFICE

F8-134

OFFICE

F8-132C

ELEVATOR NO.

E9

STAIRWELL NO.

S20

JAN. CLOSET

F8-153

CORRIDOR

C8-11

CORRIDOR

C8-10

CORRIDOR

C8-9

FEC

FE FAP

FAP

FAP

MECH.

SPRINKLER

VALVES

M8-226C

189 SF

TR

F8-000

396 SF

FB-120

117 SF

F8-104

183 SF

F8-107

268 SF

F8-109

402 SF

F8-127

397 SF

PHASE 1: CONTRACTOR TO

COMPLETE THE WORK OF THIS

TR AND ASSOCIATED DATA

DROPS. COMPLETE ONE

SECTION AT A TIME AS

DIRECTED TO COR.

TR

SECTION 1A:

CONTRACTOR TO COORDINATE

WITH VA FOR ROOM

CLOSURES AND AVAILABILITY

TO COMPLETE DATA WIRING IN

THIS AREA

SECTION 2A:

CONTRACTOR TO COORDINATE

WITH VA FOR ROOM

CLOSURES AND AVAILABILITY

TO COMPLETE DATA WIRING IN

THIS AREA

R 7 5' -

15.M

FEC/FE REQUIRED WITHIN

75' RADIUS AROUND TR/TE

15.1.2

F8-000

ICRA CLASS II

ICRA CLASS III

ICRA CLASS IV

TR

TR

FIRE EXTINGUISHER CLOSETFEC

FIRE EXTINGUISHERFE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

EHRM INFRASTRUCTURE

UPGRADES - KANSAS CITY, MO

KANSAS CITY VAMC 4801 LINWOOD BLVD KANSAS CITY, MO 64128

589-21-700

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 203

KENT, WA 98032

(206) 590-2118

RAY SPEES 15AS108

BUILDING 15 - LEVEL 08 - PHASING

PLAN 15

MA/EM DD/ADSI

100% CONSTRUCTION

DOCUMENTS

06/19/2023

LEGENDLEGEND

KEY PLAN

1" = 10'-0"

BUILDING 15 - LEVEL 08 - PHASING PLAN

0' 5' 10' 20'

PROJECT

NORTH

Revisions: Date:

GENERAL NOTES

DUST MITIGATION NOTES

1. FOR THOSE CLOSETS IDENTIFIED TO REMAIN IN PLACE AND

BE REMODELED, THE CONTRACTOR SHALL WORK CLOSELY

WITH THE COR AND OIT TO PROTECT ALL EQUIPMENT FROM

THE HAZARDOUS EFFECTS OF DUST AND DEBRIS THAT WILL

BE GENERATED FROM CONSTRUCTION ACTIVITIES. THE

CONTRACTOR SHALL PROVIDE A LIST OF THOSE SPACES

THAT MAY BE ADVERSELY AFFECTED BY CONSTRUCTION TO

THE COR PRIOR TO THE START OF ANY CONSTRUCTION

ACTIVITIES.

2. CONTRACTOR SHALL SUBMIT A PLAN OF ACTION TO

MITIGATE THE EFFECTS OF DUST, DIRT AND DEBRIS WHICH

MAY INCLUDE THE FOLLOWING: PLASTIC SHEETING, CLEAN

AIR RECIRCULATION, SHORT DURATION POWER OUTAGES,

OFF HOURS WORK, ADDITIONAL CLEANING OF THE AREA

AFFECTED, TEMPORARY RELOCATION WITHIN THE ROOM OF

EQUIPMENT.

3. THE TYPES OF EQUIPMENT THAT MAY NEED PROTECTION

FROM CONSTRUCTION ACTIVITIES INCLUDES BUT IS NOT

LIMITED TO: RACK MOUNTED SERVERS, ROUTERS AND

SWITCH GEAR, FIRE ALARM PANELS, ACCESS CONTROL

PANELS, NURSE CALL, CCTV, SMOKE DETECTORS AND FIBER

OPTIC ENCLOSURES.

4. THE CONTRACTOR SHALL CLEAN ALL AREAS AFTER EACH

WORK PERIOD WITH VACUUMS THAT HAVE HEPA FILTERS IN

PLACE TO MINIMIZE THE RECIRCULATION OF DUST AND DIRT.

CONTRACTOR SHALL ALSO WIPE DOWN EQUIPMENT WITH

CLEANING WIPES TO ASSURE ANY EXCESS DUST IS

REMOVED.

5. THE CONTRACTOR SHALL PROVIDE PORTABLE COOLING AS

REQUIRED FOR ANY TELECOM RACKS REMAINING IN PLACE

DURING CONSTRUCTION ACTIVITIES.

A/E:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 203

KENT, WA 98032

(206) 590-2118

94 of 512Page 94 of 518

15.4 15.3 15.2 15.1

15.L

15.K

15.J

15.H

15.G

15.F

15.E

15.D

15.C

15.A

Room

F9-150B

Room

F9-150

STAIRWELL NO.

S14

15.B

SECTION 1B:

CONTRACTOR TO COORDINATE

WITH VA FOR ROOM

CLOSURES AND AVAILABILITY

TO COMPLETE DATA WIRING IN

THIS AREA.

SECTION 1A:

CONTRACTOR TO COORDINATE

WITH VA FOR ROOM

CLOSURES AND AVAILABILITY

TO COMPLETE DATA WIRING IN

THIS AREA.

SHOWN AREA

PROJECT

NORTH

ICRA CLASS II

ICRA CLASS III

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

EHRM INFRASTRUCTURE

UPGRADES - KANSAS CITY, MO

KANSAS CITY VAMC 4801 LINWOOD BLVD KANSAS CITY, MO 64128

589-21-700

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 203

KENT, WA 98032

(206) 590-2118

RAY SPEES 15AS109

BUILDING 15 - LEVEL 09 - PHASING

PLAN 15

MA/EM ML/CO

100% CONSTRUCTION

DOCUMENTS

06/19/2023

1" = 10'-0"

BUILDING 15 - LEVEL 09 - PHASING PLAN

LEGENDLEGEND

KEY PLAN

0' 5' 10' 20'

PROJECT

NORTH

Revisions: Date:

GENERAL NOTES

DUST MITIGATION NOTES

1. FOR THOSE CLOSETS IDENTIFIED TO REMAIN IN PLACE AND

BE REMODELED, THE CONTRACTOR SHALL WORK CLOSELY

WITH THE COR AND OIT TO PROTECT ALL EQUIPMENT FROM

THE HAZARDOUS EFFECTS OF DUST AND DEBRIS THAT WILL

BE GENERATED FROM CONSTRUCTION ACTIVITIES. THE

CONTRACTOR SHALL PROVIDE A LIST OF THOSE SPACES

THAT MAY BE ADVERSELY AFFECTED BY CONSTRUCTION TO

THE COR PRIOR TO THE START OF ANY CONSTRUCTION

ACTIVITIES.

2. CONTRACTOR SHALL SUBMIT A PLAN OF ACTION TO

MITIGATE THE EFFECTS OF DUST, DIRT AND DEBRIS WHICH

MAY INCLUDE THE FOLLOWING: PLASTIC SHEETING, CLEAN

AIR RECIRCULATION, SHORT DURATION POWER OUTAGES,

OFF HOURS WORK, ADDITIONAL CLEANING OF THE AREA

AFFECTED, TEMPORARY RELOCATION WITHIN THE ROOM OF

EQUIPMENT.

3. THE TYPES OF EQUIPMENT THAT MAY NEED PROTECTION

FROM CONSTRUCTION ACTIVITIES INCLUDES BUT IS NOT

LIMITED TO: RACK MOUNTED SERVERS, ROUTERS AND

SWITCH GEAR, FIRE ALARM PANELS, ACCESS CONTROL

PANELS, NURSE CALL, CCTV, SMOKE DETECTORS AND FIBER

OPTIC ENCLOSURES.

4. THE CONTRACTOR SHALL CLEAN ALL AREAS AFTER EACH

WORK PERIOD WITH VACUUMS THAT HAVE HEPA FILTERS IN

PLACE TO MINIMIZE THE RECIRCULATION OF DUST AND DIRT.

CONTRACTOR SHALL ALSO WIPE DOWN EQUIPMENT WITH

CLEANING WIPES TO ASSURE ANY EXCESS DUST IS

REMOVED.

5. THE CONTRACTOR SHALL PROVIDE PORTABLE COOLING AS

REQUIRED FOR ANY TELECOM RACKS REMAINING IN PLACE

DURING CONSTRUCTION ACTIVITIES.

A/E:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 203

KENT, WA 98032

(206) 590-2118

95 of 512Page 95 of 518

NORTH

26.5

26.E

26.4a

/2

INTERIOR LINE

OF NEW WALLB B

B B

A

A

ENTRY

POINT

ENTRY

POINT

3' - 0"

3' - 0" 4' - 9 1/2"

REMOVE OLD

DOOR AFTER NEW

IS INSTALLED

1B B

3' - 0"

A

A

ENTRY

POINT

26.5

26.E

26.4a

26.E

26.4a

149 SF

STOCK ROOM

VB-713

3279 SF

RETAIL STORE

VB-715

100 SF

TR

VB-715A

69 SF

OFFICE

VB-715B

1079 SF

CORRIDOR

CB-60

01a

01b

VB-713

/2

8' - 5"

8' - 5"

NEW

FLOORING

EXISTING

FLOORING

10' x 8' TR

FORM FACTOR

VB-715A

26.E

26.4a

100 SF

TR

VB-715A

EXPOSED

1' - 1"

/2

/2

/2

3279 SF

RETAIL STORE

VB-715

149 SF

STOCK ROOM

VB-713

69 SF

OFFICE

VB-715B

1079 SF

CORRIDOR

CB-60

2' - 2 1/2"

1' - 1" 2' - 2 1/2"

/2

3279 SF

RETAIL STORE

VB-715

86 SF

IT CLOSET

VB-715A

164 SF

STOCK ROOM

VB-713

69 SF

OFFICE

VB-715B

1079 SF

CORRIDOR

CB-60

3279 SF

RETAIL STORE

VB-715

86 SF

IT CLOSET

VB-715A

164 SF

STOCK ROOM

VB-713

69 SF

OFFICE

VB-715B

1079 SF

CORRIDOR

CB-60

RM VB-713

EXISTING DOOR TO REMAIN

NEW DOOR

TO DEMOLISH

EXISTING DOOR TO DEMOLISH

EXISTING WALL TO DEMOLISH

EXISTING LIGHTS TO DEMOLISH

NEW LIGHTS (SEE ELECTRICAL DETAILS)

POLYETHYLENE SHEETING

CONSTRUCTION TACKY MATT

HEPA EQUIPPED AIR FILTER

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

EHRM INFRASTRUCTURE

UPGRADES - KANSAS CITY, MO

KANSAS CITY VAMC 4801 LINWOOD BLVD KANSAS CITY, MO 64128

589-21-700

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 203

KENT, WA 98032

(206) 590-2118

RAY SPEES 26A-100

BLDG 26 - LEVEL 00 - DEMO,

FLOOR PLANS & RCPS 26

MA/EM DD/KB/CO

100% CONSTRUCTION

DOCUMENTS

06/19/2023

LEGEND

KEY NOTES (THIS SHEET ONLY)

1/4" = 1'-0"

RM VB-715A - DEMO FLOOR PLAN

1/4" = 1'-0"

RM VB-715A - DEMO RCP

1/4" = 1'-0"

RM VB-715A - FLOOR PLAN

1/4" = 1'-0"

RM VB-715A - RCP

PROJECT

NORTH

PROJECT

NORTH

PROJECT

NORTH

PROJECT

NORTH

DEMOLISH EXISTING WALL. PREPARE FOR NEW

DOOR/FRAME.

DEMOLISH EXISTING DOOR/FRAME.

DEMOLISH EXISTING WALL. PATCH WALLS WHERE DEMO

OCCURS.

DEMOLISH EXISTING FLOORING TO EXPOSE CONCRETE SLAB

UNDERNEATH, REMOVE EXISTING ADHESIVE.

DEMOLISH EXISTING ACT COMPLETELY INCLUDING ALL GRID,

SUPPORTING WIRES, CLIPS, AND PERIMETER WALL ANGLES

IN ROOM TO EXPOSE UNDERSIDE OF STRUCTURE ABOVE.

INSTALL NEW DOOR/FRAME.

INFILL WALL, PATCH AND PAINT TO MATCH EXISTING.

CONSTRUCT NEW WALL, PATCH AND PAINT TO MATCH

EXISTING.

APPLY ANTI-STATIC COATING TO EXPOSED CONCRETE

FLOOR. PROVIDE VINYL REDUCER STRIP AT EXISTING

FLOORING TRANSITION.

INSTALL NEW RESILIENT RUBBER BASE AT ROOM

PERIMETER WITH SEALANT AT THE BOTTOM.

INSTALL NEW FRT PLYWOOD OVER WALLS PER DETAIL

3/AE421, TYPICAL.

INSTALL FIRE RETARDANT POLYETHYLENE SHEETING TO

ISOLATE CONSTRUCTION ZONE. TAPE AND SEAL ALONG

EDGES AND ANY AREAS WHERE POTENTIAL DUST MAY BE

EXPOSED OUTSIDE OF CONSTRUCTION AREA.

PLACE ADHESIVE WALK-OFF MATS AT ENTRANCE AND EXIT

OF CONSTRUCTION AREA. TYPICAL.

KEY PLAN

GENERAL NOTES

1. ALL PRODUCTS AND WALL FINISHES SHALL MATCH EXISTING

OR ADJACENT EXISTING UNLESS OTHERWISE NOTED.

2. PATCH AND REPAIR WALLS, FLOORS AND CEILING WHERE

MECHANICAL, PLUMBING, AND ELECTRICAL ITEMS ARE

DEMOLISHED.

3. PROTECT FINISHES IN ROOMS ADJACENT TO THE AREA OF

WORK AND PARTS THAT ARE NOT INCLUDED IN THE SCOPE.

4. CONTRACTORS SHALL LEAVE FIRE RATING STAMP

UNPAINTED AND VISIBLE ON THE NEW INSTALLED FRT

PLYWOOD. SEE DETAIL 5/AE421.

5. REFER TO SHEET AS101 FOR ICRA REQUIREMENTS AND

DETAILS.

6. PATCH AND REPAIR CEILING, WALLS AND FLOORS AS

REQUIRED WHERE ICRA BARRIERS WILL BE CONSTRUCTED

AND REMOVED.

7. PATCH AND REPAIR GWB WHERE DOOR IS DEMOLISHED AND

A NEW DOOR WILL BE INSTALLED.

A

B

ICRA CLASS II

ICRA LEGEND

ICRA KEY NOTES

Revisions: Date:

A/E:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 203

KENT, WA 98032

(206) 590-2118

96 of 512Page 96 of 518

OS

OS

J T

1.3d26.3

26.E

ENTRY POINT

A B

B

/2

1.3d26.3

26.E

23 SF

STORAGE

V1-684A

34 SF

TE

V1-685

127 SF

TR

V1-684

119 SF

OFFICE

V1-682

100 SF

EXAM ROOM

V1-781

98 SF

EXAM ROOM

V1-783

687 SF

CORRIDOR

C1-63

V -6

RADIATION

SHIELDED

WALL

01c

9' - 1"

"N E

W

F L O

O R

IN

G

E X

IS

T

IN

G

O

O R

IN

G

10' x 8' TR

FORM FACTOR

1.3d26.3

26.E

1.3d26.3

26.E

127 SF

TR

V1-684

687 SF

CORRIDOR

C1-63

34 SF

TE

V1-685

23 SF

STORAGE

V1-684A

687 SF

CORRIDOR

C1-63

573 SF

CHECK-IN/OUT

V1-706

EXPOSED

1' - 4"

/2

1' - 4"

0' - 8"

/2

1' - 4"

137 SF

SUPPLY ROOM

V1-684

34 SF

ELEC

V1-685

23 SF

STORAGE

V1-684A

119 SF

OFFICE

V1-682

100 SF

EXAM ROOM

V1-781

98 SF

EXAM ROOM

V1-783

687 SF

CORRIDOR

C1-63

137 SF

SUPPLY ROOM

V1-684

34 SF

ELEC

V1-685

23 SF

STORAGE

V1-684A

119 SF

OFFICE

V1-682

100 SF

EXAM ROOM

V1-781

98 SF

EXAM ROOM

V1-783

687 SF

CORRIDOR

C1-63

V1-684

EXISTING DOOR TO REMAIN

NEW DOOR

TO DEMOLISH

EXISTING DOOR TO DEMOLISH

EXISTING WALL TO DEMOLISH

EXISTING LIGHTS TO DEMOLISH

NEW LIGHTS (SEE ELECTRICAL DETAILS)

SHOWN AREA

PROJECT

NORTH

POLYETHYLENE SHEETING

CONSTRUCTION TACKY MATT

HEPA EQUIPPED AIR FILTER

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

EHRM INFRASTRUCTURE

UPGRADES - KANSAS CITY, MO

KANSAS CITY VAMC 4801 LINWOOD BLVD KANSAS CITY, MO 64128

589-21-700

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 203

KENT, WA 98032

(206) 590-2118

RAY SPEES 26A-101

BLDG 26 - LEVEL 01 - DEMO,

FLOOR PLANS & RCPS 26

MA/EM DD/ML/CO

100% CONSTRUCTION

DOCUMENTS

06/19/2023

LEGEND

1/4" = 1'-0"

RM V1-684 - DEMO FLOOR PLAN

1/4" = 1'-0"

RM V1-684 - FLOOR PLAN

1/4" = 1'-0"

RM V1-684 - DEMO RCP

1/4" = 1'-0"

RM V1-684 - RCP

PROJECT

NORTH

PROJECT

NORTH

PROJECT

NORTH

DEMOLISH EXISTING DOOR/FRAME.

DEMOLISH EXISTING FLOORING TO EXPOSE CONCRETE SLAB

UNDERNEATH. REMOVE EXISTING ADHESIVE. PREPARE

FLOORING FOR NEW WORK.

DEMOLISH EXISTING ACT COMPLETELY INCLUDING ALL

GRIDS, SUPPORTING WIRES, CLIPS, AND PERIMETER WALL

ANGLES TO EXPOSE UNDERSIDE OF STRUCTURE ABOVE.

PATCH WALLS WHERE CEILING IS REMOVED.

INSTALL NEW DOOR/FRAME.

APPLY ANTI-STATIC COATING TO EXPOSED CONCRETE

FLOOR. PROVIDE VINYL REDUCER STRIP AT EXISTING

FLOORING TRANSITION.

INSTALL NEW RESILIENT RUBBER BASE AT ROOM PERIMETER

WITH SEALANT AT THE BOTTOM.

INSTALL NEW FRT PLYWOOD OVER WALLS PER DETAIL

3/AE421, TYPICAL.

INSTALL FIRE RETARDANT POLYETHYLENE SHEETING TO

ISOLATE CONSTRUCTION ZONE. TAPE AND SEAL ALONG

EDGES AND ANY AREAS WHERE POTENTIAL DUST MAY BE

EXPOSED OUTSIDE OF CONSTRUCTION AREA.

PLACE ADHESIVE WALK-OFF MATS AT ENTRANCE AND EXIT

OF CONSTRUCTION AREA. TYPICAL.

KEY NOTES (THIS SHEET ONLY)

KEY PLAN

GENERAL NOTES

1. ALL PRODUCTS AND WALL FINISHES SHALL MATCH EXISTING

OR ADJACENT EXISTING UNLESS OTHERWISE NOTED.

2. PATCH AND REPAIR WALLS, FLOORS AND CEILING WHERE

MECHANICAL, PLUMBING, AND ELECTRICAL ITEMS ARE

DEMOLISHED.

3. PROTECT FINISHES IN ROOMS ADJACENT TO THE AREA OF

WORK AND PARTS THAT ARE NOT INCLUDED IN THE SCOPE.

4. CONTRACTORS SHALL LEAVE FIRE RATING STAMP

UNPAINTED AND VISIBLE ON THE NEW INSTALLED FRT

PLYWOOD. SEE DETAIL 5/AE421.

5. REFER TO SHEET AS101 FOR ICRA REQUIREMENTS AND

DETAILS.

6. PATCH AND REPAIR CEILING, WALLS AND FLOORS AS

REQUIRED WHERE ICRA BARRIERS WILL BE CONSTRUCTED

AND REMOVED.

7. PATCH AND REPAIR GWB WHERE DOOR IS DEMOLISHED AND

A NEW DOOR WILL BE INSTALLED.

ICRA CLASS II

ICRA LEGEND

A

B

PROJECT

NORTH

ICRA KEY NOTES

Revisions: Date:

A/E:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 203

KENT, WA 98032

(206) 590-2118

97 of 512Page 97 of 518

J

PROJECT

NORTH

RM V2-751A

26.3

26.D

26.E

26.D.1

5' - 0"

5' - 0 1/2"

/2

3' - 0" 5' - 0"

B B

A

B B

A

B B

A

26.3

26.D

26.E

26.D.1

82 SF

LOCKERS, MALE

V2-751

175 SF

CORRIDOR

C2-72

30 SF

TOILET, FEMALE

V2-749A

55 SF

TOILET, MALE

V2-751A

112 SF

A X-RAY ROOM

V2-756

103 SF

B X-RAY ROOM

V2-758

111 SF

LOCKERS,

FEMALE

V2-749

26.3

26.D

26.E

26.D.1

174 SF

LOCKERS, MALE

V2-751

418 SF

CORRIDOR

C2-71

175 SF

CORRIDOR

C2-72

103 SF

B X-RAY ROOM

V2-758

112 SF

A X-RAY ROOM

V2-756

130 SF

TR

V2-749

IN-03.01-11

01a

01b

V2-749

11' - 10 1/2"

/2

11' - 10 1/2"

NEW

FLOORING

EXISTING

FLOORING

10' x 10' TR

FORM FACTOR

26.3

26.D

26.E

26.D.1

418 SF

CORRIDOR

C2-71

174 SF

LOCKERS, MALE

V2-751

175 SF

CORRIDOR

C2-72

112 SF

A X-RAY ROOM

V2-756

103 SF

B X-RAY ROOM

V2-758

130 SF

TR

V2-749

EXPOSED

/2

/2

2' - 0 1/2" 2' - 0 1/2"

/2

82 SF

LOCKERS, MALE

V2-751

175 SF

CORRIDOR

C2-72

30 SF

TOILET, FEMALE

V2-749A

55 SF

TOILET, MALE

V2-751A

112 SF

A X-RAY ROOM

V2-756

103 SF

B X-RAY ROOM

V2-758

111 SF

LOCKERS,

FEMALE

V2-749

POLYETHYLENE SHEETING

CONSTRUCTION TACKY MATT

HEPA EQUIPPED AIR FILTER

EXISTING DOOR TO REMAIN

NEW DOOR

TO DEMOLISH

EXISTING DOOR TO DEMOLISH

EXISTING WALL TO DEMOLISH

EXISTING LIGHTS TO DEMOLISH

2HR FIRE RATED WALL

NEW LIGHTS (SEE ELECTRICAL DETAILS)

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 -…