Attachment 3 P11 Vol2 Drawings SS Final.pdf
PDF 24 MB Posted
- Solicitation number
- 36C77626B0023
About this file
This file is an architectural drawing set (P11 Vol2) for the CLC Residential Neighborhood construction project. The drawings are final specifications prepared for the Department of Veterans Affairs Technology Acquisition Center Austin and depict the structural and design elements for Project 586-401 in Jackson, Mississippi. The document serves as technical reference material for contractors bidding on or executing the residential construction work, providing detailed visual representations of building layouts, dimensions, and construction specifications necessary for project implementation. These drawings are essential supporting documentation for the solicitation and would guide contractors in understanding the scope of work, site configuration, and architectural requirements for constructing the CLC residential neighborhood. The drawings represent the final approved design that contractors must follow during construction execution.
View the file
Other files
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
PROJECT SITE MAP
STREET FACING BUILDING EXTERIOR PERSPECTIVE
PROJECT LOCATION MAP
/1
/2
:0
:3
A
M C
U s e rs
\J lo n g h u rs t\ D o c u m e n ts \A
-0
-V A
J a c k s o n
-C o n s tr u c t C
L C
R jlo n g h u rs tS M
A W
.r v t
G-001.5
COVER
1 1JNL
CLC RESIDENTIAL
NEIGHBORHOOD
G.V. MONTGOMERY VAMC
1500 E. WOODROW WILSON AVENUE
JACKSON, MS 39216 JUNE 23, 2025
100% CONSTRUCTION DOCUMENTS
586-40123-060
7A
CLC RESIDENTIAL NEIGHBORHOOD
G.V. MONTGOMERY VAMC
1500 E. WOODROW WILSON AVENUE
JACKSON, MS 39216
VA PROJECT #: 586-401
KC
JACKSON VA CLINIC
NORTH
JACKSON VA CLINIC
NORTH
VOLUME 2 OF 2
DRAWING LIST
GENERAL
G-001 COVER 1 7
G-002 GENERAL INFORMATION 2 7
G-003 CODE SUMMARY - NFPA 101 3 7
G-004 ICRA INFORMATION AND DETAILS 4 7
G-005 OVERALL SITE LOGISTICS PLAN 5 7
G-006 SITE LOGISTICS PLAN 6 7
GL101 GROUND FLOOR LIFE SAFETY PLAN 7 7
CIVIL
CD101 CIVIL DEMOLITION PLAN 1 6
CS101 CIVIL SITE & UTILITY PLAN 2 6
CS102 CIVIL DEDUCT ALTERNATE SITE GRADING & UTILITY PLAN 3 6
CG101 GRADING & DRAINAGE PLAN 4 6
CG102 STORM AND SANITARY SEWER PROFILES 5 6
CS501 CIVIL DETAILS 6 6
LANDSCAPE
LP101 LANDSCAPE PLAN 1 3
LP102 LANDSCAPE DEDUCTIVE ALTERNATE PLAN 2 3
LP501 LANDSCAPE DETAILS 3 3
STRUCTURAL
S-001 STRUCTURAL SYMBOLS, ABBREVIATIONS AND NOTES 1 23
S-002 STRUCTURAL SCHEDULES 2 23
S-003 STRUCTURAL SCHEDULES 3 23
S-101 FOUNDATION PLAN 4 23
S-101.1 FOUNDATION PLAN - DEDUCT ALTERNATE #6 5 23
S-102 FOUNDATION WALL PLAN 6 23
S-102.1 FOUNDATION WALL PLAN - DEDUCT ALTERNATE #6 7 23
S-103 GROUND FLOOR PLAN 8 23
S-103.1 GROUND FLOOR PLAN - DEDUCT ALTERNATE #6 9 23
S-104 GROUND FLOOR WALL PLAN 10 23
S-104.1 GROUND FLOOR WALL PLAN - DEDUCT ALTERNATE #2, #6, #12 11 23
S-105 ROOF FRAMING PLAN 12 23
S-105.1 ROOF FRAMING PLAN - DEDUCT ALTERNATE #6 13 23
S-106 ROOF WALL FRAMING PLAN 14 23
S-106.1 ROOF WALL FRAMING PLAN - DEDUCT ALTERNATE #6 15 23
S-107 PERGOLA FOUNDATION PLAN 16 23
S-201 WALL SECTIONS 17 23
S-202 WALL SECTIONS 18 23
S-203 WALL SECTIONS 19 23
S-204 WALL SECTIONS - DEDUCT ALTERNATE #6 20 23
S-301 DETAILS 21 23
S-302 DETAILS 22 23
S-303 DETAILS 23 23
ARCHITECTURAL
A-001 ARCHITECTURAL SYMBOLS, ABBREVIATIONS AND NOTES 1 35
AD101 GROUND AND FIRST FLOOR DEMOLITION PLANS 2 35
AD102 EXTERIOR ELEVATIONS & AXONOMETRIC DEMOLITION 3 35
AD103 TEMPORARY COURTYARD DEMOLITION AND ADDITION 4 35
AD104 EXTERIOR WALL SECTIONS AND DETAILS DEMOLITION 5 35
A-100 OVERALL SITE & FUTURE GROWTH PLAN 6 35
A-100.1 OVERALL SITE & FUTURE GROWTH PLAN - SITE DEDUCT ALTERNATES 7 35
A-101 GROUND FLOOR PLAN 8 35
A-101.1 GROUND FLOOR PLAN - DEDUCT ALTERNATES 9 35
A-102 GROUND FLOOR DIMENSION PLAN 10 35
A-103 EDGE OF SLAB PLANS 11 35
A-104 GROUND FLOOR REFLECTED CEILING PLAN 12 35
A-104.1 GROUND FLOOR REFLECTED CEILING PLAN - DEDUCT ALTERNATES 13 35
A-105 ROOF PLAN / ROOF DEDUCT ALTERNATES 14 35
A-201 EXTERIOR ELEVATIONS 15 35
A-201.1 EXTERIOR ELEVATIONS - DEDUCT ALTERNATES 16 35
A-301 BUILDING SECTIONS 17 35
A-301.1 BUILDING SECTIONS - DEDUCT ALTERNATES 18 35
A-302 WALL SECTIONS - SCREEN PORCH 19 35
A-303 WALL SECTIONS - WITH DEDUCT ALTERNATES 20 35
A-304 WALL SECTIONS - WITH DEDUCT ALTERNATES 21 35
A-305 WALL SECTIONS - WITH DEDUCT ALTERNATES 22 35
A-306 WALL SECTIONS 23 35
A-307 ENLARGED PLAN DETAILS 24 35
A-401 FENCE AND PILASTER DETAILS 25 35
A-421 ENLARGED TOILET PLANS AND ELEVATIONS 26 35
A-501 EXTERIOR DETAILS - PENETRATION AND ROOF DETAILS 27 35
A-502 EXTERIOR MASONRY DETAILS - BRICK ON MTL STUDS 28 35
A-503 EXTERIOR DETAILS - METAL PANEL ON MTL STUDS (WITH DEDUCT ALTERNATES) 29 35
A-510 PARTITION TYPES & INTERIOR DETAILS 30 35
A-511 COLUMN DETAILS 31 35
A-512 INTERIOR DETAILS 32 35
A-513 CEILING DETAILS 33 35
A-601 DOOR SCHEDULE, ELEVATIONS AND DETAILS 34 35
A-602 WINDOW ELEVATIONS 35 35
INTERIORS
I-001 GENERAL NOTES, ABBREVIATIONS AND ROOM FINISH SCHEDULE 1 11
I-101 GROUND FLOOR FINISH AND WALL PROTECTION PLAN 2 11
I-131 GROUND FLOOR PATTERN PLAN 3 11
I-141 GROUND FLOOR SIGNAGE PLAN 4 11
I-201 CASEWORK AND MILLWORK ELEVATIONS 5 11
I-202 CASEWORK DETAILS 6 11
I-401 INTERIOR ELEVATIONS 7 11
I-411 GROUND FLOOR OVERALL EQUIPMENT PLAN 8 11
I-421 ENLARGED EQUIPMENT PLANS 9 11
I-422 ENLARGED EQUIPMENT PLANS 10 11
I-601 EQUIPMENT AND AQUISITION SCHEDULE 11 11
EQUIPMENT
QH-101 VENDOR DRAWINGS - GULDMANN (FOR REFERENCE ONLY) 1 1
DRAWING LIST
GENERAL
G-001.5 COVER 1 1
FIRE SUPPRESSION
FX001 FIRE SUPPRESSION GENERAL INFORMATION 1 5
FX101 GROUND FLOOR FIRE SUPPRESSION PLAN 2 5
FX101.1 GROUND FLOOR FIRE SUPPRESSION PLAN - DEDUCT ALTERNATE 3 5
FX102 GROUND FLOOR FIRE SUPPRESSION REFLECTED CEILING PLAN 4 5
FX102.1 GROUND FLOOR FIRE SUPPRESSION REFLECTED CEILING PLAN - DEDUCT ALTERNATE 5 5
PLUMBING
P-001 PLUMBING GENERAL INFORMATION 1 14
PW101 GROUND FLOOR DRAIN, WASTE, AND VENT PLAN 2 14
PP101 GROUND FLOOR DOMESTIC WATER PLAN 3 14
PG101 GROUND FLOOR MEDICAL GAS PLAN 4 14
PG102 GROUND FLOOR MEDICAL GAS PLAN 5 14
PW102 ROOF PLUMBING PLAN 6 14
P-401 ENLARGED PLUMBING PLANS AND PLUMBING SECTION 7 14
P-501 PLUMBING DETAILS 8 14
P-502 PLUMBING DETAILS 9 14
P-601 PLUMBING SCHEDULES 10 14
P-901 SANITARY PIPE RISERS 11 14
P-902 DOMESTIC PIPE RISERS 12 14
P-903 STORM PIPE RISERS 13 14
P-904 MEDICAL GAS PIPE RISERS 14 14
MECHANICAL
M-001 MECHANICAL GENERAL INFORMATION 1 15
MH101 GROUND FLOOR HVAC PLAN 2 15
MH102 ROOF HVAC PLAN 3 15
MP101 GROUND FLOOR MECHANICAL PIPING PLAN 4 15
MP101.1 GROUND FLOOR MECHANICAL PIPING PLAN - DEDUCT ALTERNATE 5 15
M-301 MECHANICAL SECTIONS 6 15
M-401 ENLARGED MECHANICAL ROOM HVAC PLAN 7 15
M-402 ENLARGED MECHANICAL ROOM PIPING PLAN 8 15
M-402.1 ENLARGED MECHANICAL ROOM PIPING PLAN - DEDUCT ALTERNATE 9 15
M-501 MECHANICAL DETAILS 10 15
M-502 MECHANICAL DETAILS 11 15
M-503 MECHANICAL DETAILS 12 15
M-504 MECHANICAL CONTROLS 13 15
M-505 MECHANICAL CONTROLS 14 15
M-601 MECHANICAL SCHEDULES 15 15
ELECTRICAL
E-001 ELECTRICAL GENERAL NOTES, SYMBOL LEGENDS, AND ABBREVIATIONS 1 13
ES101 SITE POWER AND LIGHTING PLAN 2 13
EL101 GROUND FLOOR LIGHTING PLAN 3 13
EP101 GENERATOR AND SWITCHGEAR ROOM AND PIPE BASEMENT POWER PLAN 4 13
EP102 PIPE BASEMENT EASTERN FLOOR OVERALL POWER PLAN 5 13
EP103 GROUND FLOOR POWER PLAN 6 13
EX101 ROOF LEVEL, LIGHTNING PROTECTION PLAN 7 13
EX102 EAST, NORTH, AND SOUTH LIGHTNING PROTECTION ELEVATIONS 8 13
E-401 ELECTRICAL ENLARGEMENTS 9 13
E-501 ELECTRICAL DETAILS 10 13
E-502 ELECTRICAL DETAILS 11 13
E-601 SINGLE LINE POWER DIAGRAM AND LIGHTING SCHEDULE 12 13
E-602 MECHANICAL EQUIPMENT CONNECTION & PANEL SCHEDULES 13 13
TECHNOLOGY
T-001 TECHNOLOGY GENERAL NOTES, SYMBOL LEGEND, AND ABBREVIATIONS 1 7
TS101 TECHNOLOGY SITE PLAN 2 7
T-101 CLC GROUND FLOOR TECHNOLOGY PLAN 3 7
T-102 ROOF TECHNOLOGY PLAN 4 7
T-103 FIRST FLOOR TECHNOLOGY PLAN 5 7
T-501 TECHNOLOGY DETAILS 6 7
T-502 TECHNOLOGY DETAILS 7 7
FIRE ALARM
FA001 FIRE ALARM GENERAL NOTES, SYMBOL LEGEND, AND RISER 1 3
FA101 CLC GROUND FLOOR FIRE ALARM PLAN 2 3
FA102 ROOF FIRE ALARM PLAN 3 3
- VOLUME 1 - VOLUME 2
Docusign Envelope ID: B03CFFD6-4D75-44E6-906A-763AFD2AA6C2
6/19/2025
S SS
NOTE: NOT ALL SYMBOLS MAY BE USED ON THIS PROJECT
SEMI-RECESSED SPRINKLER HEAD
UPRIGHT SPRINKLER HEAD
FIRE SUPPRESSION LINEFS
CONCEALED SPRINKLER HEAD
PENDANT SPRINKLER HEAD
SIDEWALL SPRINKLER HEAD
FIRE DEPARTMENT CONNECTION (FDC)
FIRE DRAINDRAIN
POINT OF NEW CONNECTION
LIMIT OF DEMOLITION
NEW WORK KEYNOTE
DEMOLITION KEYNOTE
FIRE PROTECTION CONTRACTORFPC
TAMPER SWITCH
FLOW SWITCH
CHECK VALVE
GATE VALVE
EXTERIOR ALARM GONG (WATER ACTIVATED)
TEST AND DRAIN ASSEMBLY
BACKFLOW PREVENTER
T&D
TS
FS
ORDINARY HAZARD
GROUP 1 OCCUPANCY
DETAIL OR SECTION MARK
SHOWN ON DRAWING
DETAIL MODULE NUMBER
ORDINARY HAZARD
GROUP 2 OCCUPANCY
LIGHT HAZARD
FIRE SUPPRESSION SYMBOLS & ABBREVIATIONS
THE FIRE PROTECTION DRAWING IS DESIGNED TO BE IN CONFORMANCE WITH NFPA 13.
IT IS A PERFORMANCE BASED DRAWING INDICATING THE EXTENT OF FIRE PROTECTION
WORK FOR THE AREA THAT THIS DRAWING REPRESENTS. THIS DRAWING IS “FOR
INFORMATION ONLY”, AS A REFERENCE FOR THE FIRE PROTECTION CONTRACTOR TO
BASE THE DESIGN OF THE FIRE PROTECTION SYSTEM ON. THE CONTRACTOR SHALL
VERIFY THE EXACT CONDITIONS THAT THIS DRAWING REPRESENTS, INCLUDING ANY
PERCEIVED CONCEALED SPACES, AND THE BUILDING TYPE AND CONSTRUCTION AS
OUTLINED IN THE INTERNATIONAL BUILDING CODE, PRIOR TO THE START OF WORK.
REFER TO NFPA 13, AND THE PROJECT SPECIFICATIONS FOR OTHER FIRE PROTECTION
REQUIREMENTS.
FLUSHING CONNECTION
FEED OR CROSS MAIN.
TYPICAL TEE WITH
CROSS MAIN PITCH
TOWARDS FEED MAIN.
NOTE: INSTALL FLUSHING
CONNECTION AT END OF
CROSS MAINS.
2" NIPPLE 4" LONG
WITH CAP.
MECHANICAL TEE
NEW PIPING
MECHANICAL TEE
SCREWED END
STEEL BEAM
RETAINING STRAP
C-CLAMP
THREADED HANGER ROD
ADJUSTABLE RING HANGER
NOTE:
HANGING DETAILS SHOWN ARE SUBJECT TO REQUIREMENTS OF SEISMIC DESIGN.
EXPANSION ANCHOR HILTI QUIK
BOLT TZ OR APPROVED EQUAL.
EXPANSION ANCHOR SHALL BE
QUALIFIED FOR USE IN CRACKED
CONCRETE PER ACI 355.2
EXISTING CONCRETE SLAB
AUTO. SPRINKLER PIPE
SET SCREW
SURGE RESTRAINER
DUCTWORK OR OTHER
OBSTRUCTION OVER
48" IN WIDTH.
UPRIGHT HEAD
SPRINKLER BRANCH LINE
ALL EXPOSED
SPRINKLER PIPING
SHALL BE PAINTED RED.
UPRIGHT HEAD.
PROVIDE GUARD.
NOTE:
1. PROVIDE SPRINKLER ABOVE AND BELOW DUCT OR OTHER OBSTRUCTION OVER 48" IN WIDTH.
2. COORDINATE SPRINKLER PIPE ROUTING AND LOCATION WITH COR AND ALL PARTIES INVOLVED WITH
INSTALLATION OF THE OBSTRUCTION.
3. PROVIDE PIPE SUPPORTS THAT COMPLY WITH NFPA 13 REQUIREMENTS. INCLUDE COST OF ADDITIONAL
SUPPORTS AS REQUIRED.
4. ATTACH PIPE SUPPORTS TO BUILDING STRUCTURE OR PROVIDE SUPPLEMENTAL STEEL ANCHOR POINTS. DO NOT ATTACH PIPE SUPPORTS TO DUCTWORK, PIPES, CONDUIT, OR EXISTING HANGER RODS FOR OTHER
EQUIPMENT.
INSTALL INSULATION AFTER
CAULKING SLEEVE, SEAL
ANNULAR SPACE.
FIRE RATED WALL AND OR SLAB.
STEEL PIPE SLEEVE TERMINATE
SLEEVE FLUSH WITH FINISHED
SURFACE.
UL-LISTED FIRESTOPPING
FINISHED ESCUTCHEON PLATE
FLUSH AGAINST WALL AND OF
SIZE TO COMPLETELY COVER
OPENING.
APPROVED TYPE FIRE SAFE &
SMOKE TIGHT CAULKING SEALER
BETWEEN BARE PIPE AND SLEEVE.
NOTE:
MINIMUM SIZE OF OPENINGS AROUND SPRINKLER PIPE PENETRATIONS OF CONCRETE OR CMU WALLS
SHALL BE IN ACCORDANCE WITH NFPA 13 SEISMIC REQUIREMENTS.
1" X ARMOVER
1" 90 EL
1" X DROP
DROP NIPPLE
1" x 1/2" R.C. REDUCER
NOTE:
1. ALL SPRINKLERS SHALL BE FM APPROVED QUICK RESPONSE.
2. ALL EXPOSED PIPING SHALL BE PAINTED RED.
3. USE FLEXIBLE SPRINKLER HEAD PIPE.
SUSPENDED CEILING
HANGERS SHALL
BE PROVIDED AS
REQUIRED BY
NFPA 13 TYPICAL
1" x 2" NIPPLE
BRANCH LINE
PENDENT SPRINKLER HEAD
1. LOCATIONS SHOWN FOR EXISTING FIRE PROTECTION PIPE AND EQUIPMENT ARE APPROXIMATE. FIELD VERIFY THE EXACT LOCATIONS OF EXISTING FIRE PROTECTION LINES AND EQUIPMENT INCLUDING RISERS AND VALVES PRIOR TO START OF
WORK.
2. COORDINATE WITH COR FOR ANY SHUTDOWNS OR PLANNED INTERRUPTIONS OF THE FIRE PROTECTION SERVICE. GIVE THE
COR THREE (3) DAYS NOTICE PRIOR TO PLANNED SHUTDOWN OR INTERRUPTION.
FIRE SUPPRESSION DEMOLITION GENERAL NOTES
1. USE NFPA-13 (CURRENT EDITION), “PLANS AND CALCULATIONS CHAPTER” AS A GUIDELINE WHEN PREPARING SUBMITTALS FOR REVIEW. DISREGARD ONLY THOSE ITEMS NOT APPLICABLE TO THE INDIVIDUAL BUILDING SYSTEM. FIRE PROTECTION MATERIALS, EQUIPMENT AND INSTALLATION SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA-13 FOR THE
INSTALLATION OF AUTOMATIC SPRINKLER SYSTEM.
2. INSTALLATION SHALL COMPLY WITH NFPA AND VA REQUIREMENTS.
3. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS AND ROOM FINISH SCHEDULE WHICH INDICATE CEILING HEIGHTS.
COORDINATE WITH ARCHITECT'S REFLECTED CEILING PLAN FOR LOCATION OF SPRINKLER HEADS IN AREAS WITH CEILINGS.
LOCATE HEADS IN AREAS WITHOUT CEILINGS AS REQUIRED BY NFPA AND VA REQUIREMENTS FOR THE APPROPRIATE
HAZARD CLASSIFICATION.
4. THIS FACILITY IS FULLY SPRINKLERED. FIRE SUPPRESSION SYSTEM SHALL BE WET PIPE TYPE SYSTEM WITH COMPLETE SPRINKLER PROTECTION UNLESS NOTED OTHERWISE. SYSTEM TO BE DESIGNED AS REQUIRED BY NFPA AND VA
REQUIREMENTS FOR THE APPROPRIATE HAZARD CLASSIFICATION.
5. SPRINKLER HEAD LAYOUTS INDICATED ARE BASED ON OCCUPANCY HAZARD CLASSIFICATIONS OUTLINED IN NFPA-13 AND VA
STANDARDS.
6. HYDRAULICALLY CALCULATE SPRINKLER DEMAND IN ACCORDANCE WITH REQUIREMENTS FOR APPROPRIATE HAZARD OCCUPANCY. PROVIDE ACTUAL NUMBER OF HEADS, REQUIRED SPACING AND PIPE ROUTING AS REQUIRED FOR CLEARANCE WITH STRUCTURAL CONDITIONS AND OTHER TRADES TO PROVIDE A COMPLETE AND OPERABLE SYSTEM IN ACCORDANCE
WITH NFPA AND VA REQUIREMENTS.
7. FIRE PROTECTION CONTRACTOR SHALL OBTAIN FLOW TEST DATA INDICATING THE WATER FLOW, STATIC PRESSURE AVAILABLE WITH NO FLOW, AND RESIDUAL PRESSURE AT FULL FLOW TO THE FACILITY. SUBMIT HYDRAULIC CALCULATIONS
AND PLANS RELATED TO A MINIMUM OF 1 REMOTE AREA FOR REVIEW.
8. PIPING IS SHOWN IN SCHEMATIC FORM TO INDICATE APPROXIMATE ARRANGEMENT OF EQUIPMENT AND PIPING. SPRINKLER CONTRACTOR SHALL DESIGN THE SYSTEM AND ROUTE PIPING AS REQUIRED FOR CONFORMANCE WITH ACTUAL BUILDING CONDITIONS AND NFPA REQUIREMENTS. COORDINATE SPRINKLER WORK WITH ALL OTHER TRADES TO AVOID CONFLICT.
9. SUPPORT NEW PIPING AND EQUIPMENT FROM STRUCTURE. PROVIDE ALL SUPPLEMENTAL STEEL TO SPAN BETWEEN PRIMARY BUILDING STRUCTURAL MEMBERS. DESIGN SUPPLEMENTAL STEEL AND SUPPORTS INCLUDING REACTION LOADS
AT PRIMARY BUILDING STRUCTURAL MEMBERS.
10. PROVIDE SPRINKLER HEADS IN CONCEALED LOCATIONS IN ACCORDANCE WITH NFPA REQUIREMENTS.
11. CLEAN ENTIRE WORK AREA OF ALL DUST, DIRT, AND OTHER DEBRIS. MAINTAIN WORK AREA IN CLEAN CONDITION.
12. PROVIDE ALL LABOR, MATERIALS, TOOLS, EQUIPMENT, ETC. REQUIRED FOR COMPLETE AND FUNCTIONAL SYSTEM AS
SPECIFIED AND INDICATED ON THE DRAWINGS.
13. SUBMIT ONE COMPLETE SET OF AUTOMATIC SPRINKLER SYSTEM DRAWINGS, HYDRAULIC CALCULATIONS, CURRENT WATER FLOW TEST, AND THE EQUIPMENT DATA BROCHURES PREPARED BY OR UNDER THE SUPERVISION OF, AND SEALED BY A
PROFESSIONAL ENGINEER.
14. REPAIR OR REPLACE NON-CONFORMING AND INADEQUATE WORK AT NO ADDITIONAL COST TO THE VA.
15. PROVIDE FIRE STOPS / SEALANT AT ALL PIPE PENETRATIONS THROUGHOUT FIRE RATED WALLS. REVIEW ARCHITECTURAL
PLANS PRIOR TO BIDDING AND INDICATE PENETRATIONS ON SPRINKLER LAYOUT SUBMITTAL.
16. FLOW AND TAMPER SWITCHES ARE TO BE PURCHASED AND INSTALLED AS WORK OF DIVISION 21. PROVIDE WIRING TO FLOW
AND TAMPER SWITCHES AS WORK OF DIVISION 26.
17. WATER SERVICE AND DETECTOR TYPE REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER TO BE PROVIDED AND TESTED AS WORK OF DIVISION 22. INCORPORATE ASSOCIATED PRESSURE DROP OF SELECTED BACKFLOW PREVENTER
DEVICE IN HYDRAULIC CALCULATIONS.
18. FURNISH AND INSTALL ARMOVER SUPPORTS FOR ALL END OF LINE BRANCH LINES IN ACCORDANCE WITH NFPA-13.
19. ALL DROPS TO SPRINKLER HEADS SHALL TEE / ELBOW OFF TOP OF BRANCH PIPE, EXCEPT WHERE STRUCTURAL, ARCHITECTURAL OR MECHANICAL EQUIPMENT CONDITIONS PRECLUDE CONNECTION AT TOP OF PIPE.
20. SPRINKLER HEADS SHALL BE IN A SYMMETRICAL PATTERN, NOT NECESSARILY IN THE CENTER OF ROOMS OR CORRIDORS.
LOCATE CENTERED IN CEILING TILE WHERE POSSIBLE.
21. LOCATE THE INSPECTOR'S TEST CONNECTION AND MAIN DRAIN LOCATIONS IN ACCORDANCE WITH NFPA-13.
22. FIRE DEPARTMENT CONNECTION SHALL BE LOCATED NOT MORE THAN 100 FEET AWAY FROM THE NEAREST FIRE HYDRANT CONNECTED TO AN APPROVED WATER SUPPLY AND SHALL BE LOCATED NOT LESS THAN 18 INCHES, NOR MORE THAN 48
INCHES ABOVE ADJACENT SURFACE.
23. STANDPIPES SHALL BE PROVIDED IN EACH REQUIRED EGRESS STAIRWAY, WITH 4 INCH DIAMETER MINIMUM SIZE.
24. CLASS 1 SYSTEM SHALL BE PROVIDED WITH 2 1/2 INCH HOSE CONNECTIONS AT EACH INTERMEDIATE LANDING BETWEEN FLOORS IN EACH REQUIRED EGRESS EXIT STAIRWAY. COORDINATE TYPE OF HOSE CONNECTIONS WITH THE LOCAL FIRE
DEPARTMENT.
25. CONTRACTOR RESPONSIBLE FOR PROVIDING ALL TESTING ASSOCIATED WITH FIRE PROTECTION SYSTEM COMMISSIONING
PER SPECIFICATIONS.
FIRE SUPPRESSION GENERAL NOTES
1. DURING THE TIME THAT THE FIRE PROTECTION RENOVATION WORK IS BEING PERFORMED AND THE FIRE PROTECTION SYSTEM IS OUT OF COMMISSION, CONTRACTOR SHALL HAVE SUFFICIENT PERSONNEL ONSITE TO KEEP A “FIRE WATCH” ON THE FACILITY IN ACCORDANCE WITH VA REQUIREMENTS. AN OUT OF SERVICE TAG MUST BE PLACED AT THE FIRE ALARM PANEL AND THE FIRE DEPARTMENT CONNECTION. REFER TO INTERNATIONAL FIRE CODE CHAPTER 9, SECTION 901.7.
2. FIRE WATCH PERSONNEL ARE TO KEEP WATCH FOR FIRES IN THE GENERAL AREA OF PERFORMANCE - THE PERSONS
PERFORMING THE FIRE WATCH ARE NOT PERMITTED TO PERFORM ANY OTHER DUTIES.
3. FIRE WATCH PERSONNEL ARE TO HAVE FIRE EXTINGUISHING EQUIPMENT READILY AVAILABLE AND TO BE TRAINED IN ITS USE.
4. THE QUANTITY OF PERSONNEL INVOLVED IN THE FIRE WATCH IS TO BE ADEQUATE SUCH THAT EACH FLOOR, LEVEL, AND
ROOM OF THE FIRE AREA IS COVERED.
5. REPLACE CEILING TILES AT THE END OF EACH SHIFT FOR WORK AREAS OUTSIDE OF A RATED CONSTRUCTION BARRIER. IF THE TILES CANNOT BE REPLACED, THE SPRINKLER SYSTEM MAY BE CONSIDERED OUT OF SERVICE IN THESE AREAS AND 1-HOUR FIRE RATED SEPARATION WILL BE REQUIRED BETWEEN THE CONSTRUCTION AREA AND THE OCCUPIED PORTIONS OF THE
BUILDING.
BUILDING AND OCCUPANT SAFETY - INTERRUPTION OF
FIRE PROTECTION SERVICE
1. CONTRACTOR SHALL COMPLY WITH THE VA'S INFECTION CONTROL RISK ASSESSMENT REQUIREMENTS AND WRITTEN DUST
CONTROL PLAN.
2. EXISTING AIR QUALITY REQUIREMENTS AND OTHER UTILITY REQUIREMENTS FOR OCCUPIED AREAS SHALL BE MAINTAINED.
3. RENOVATION AREAS SHALL BE ISOLATED FROM OCCUPIED AREAS DURING CONSTRUCTION USING AIRTIGHT BARRIERS.
PROVIDE EXHAUST AIRFLOW IN A MANNER THAT SHALL BE SUFFICIENT TO MAINTAIN NEGATIVE AIR PRESSURE IN THE CONSTRUCTION ZONE. COORDINATE TEMPORARY BARRIERS WITH INTERIM LIFE SAFETY MEASURES.
4. FIRE PROTECTION SYSTEM REVISIONS SHALL BE PROPERLY PERFORMED TO LIMIT WATERBORNE OPPORTUNISTIC
PATHOGENS.
5. CRUCIAL VENTILATION SPECIFICATIONS FOR AIR BALANCE AND FILTRATION SHALL BE VERIFIED BEFORE COR ACCEPTANCE.
INFECTION CONTROL MEASURES
STATIC PSI RESIDUAL PSI FLOW GPM DATE LOCATION FLOW TEST PERFORMED BY
84 76 1186 08/27/2022
FIRE HYDRANT
FIVE
CAPITOL CHLORINATOR &
UTILITY SERVICE, INC.
THE FLOW TEST INFORMATION LISTED ABOVE IS INTENDED AS A REFERENCE FOR THE FIRE PROTECTION CONTRACTOR. THE FIRE
PROTECTION CONTRACTOR SHALL PERFORM A HYDRAULIC FLOW TEST NEAR THE PROJECT SITE TO VERIFY ACTUAL FLOW
CONDITIONS ON WHICH TO BASE THE FIRE PROTECTION DESIGN.
FLOW TEST INFORMATION
BID DEDUCT ALTERNATE #1
ALL WORK IN CONTRACT EXCEPT CHANGE FENCE AND PYLONS TO METAL
FENCE. SEE SHEET A-101.1.
BID DEDUCT ALTERNATE #2
ALL WORK IN CONTRACT EXCEPT DEDUCT #1 AND SUBSTITUTE BRICK IN
PLACE OF RAINSCREEN. SEE SHEET A-201.1.
BID DEDUCT ALTERNATE #3
ALL WORK IN CONTRACT EXCEPT DEDUCT #1, #2, AND REMOVE SCREEN
SYSTEM AT FIRST-FLOOR PORCH. SEE SHEET A-201.1.
BID DEDUCT ALTERNATE #4
ALL WORK IN CONTRACT EXCEPT DEDUCT #1 THROUGH #3 AND REMOVE
SCREEN SYSTEM AT GROUND FLOOR PORCH. SEE SHEET A-201.1.
BID DEDUCT ALTERNATE #5
ALL WORK IN CONTRACT EXCEPT DEDUCT #1 THROUGH #4 AND OMIT
LANDSCAPE/HARDSCAPE IN THE SOUTHERN COURTYARD. SEE SHEET A101.1.
BID DEDUCT ALTERNATE #6
ALL WORK IN CONTRACT EXCEPT DEDUCT #1 THROUGH #5 AND ELIMINATE
SCREEN PORCH, INCLUDING ASSOCIATED LIGHT FIXTURES, LIGHTING
CONTROLS, RECEPTACLES, AND NOTIFICATION DEVICES. INSTALL LIGHT
FIXTURE M1E AT DOUBLE DOORS EXITING THE BUILDING. INSTALL PULL
STATION AT DOUBLE DOORS EXITING THE BUILDING. SEE SHEETS EL101,
EP101, AND FA101.
BID DEDUCT ALTERNATE #7
ALL WORK IN CONTRACT EXCEPT DEDUCT #1 THROUGH #6 AND ELIMINATE
LANDSCAPE LIGHTING, INCLUDING LIGHT FIXTURES AND LIGHTING CONTROLS.
SEE SHEET ES101.
BID DEDUCT ALTERNATE #8
ALL WORK IN CONTRACT EXCEPT DEDUCT #1 THROUGH #7 AND OMIT
CANOPIES. SEE SHEET A-105.
BID DEDUCT ALTERNATE #9
ALL WORK IN CONTRACT EXCEPT DEDUCT #1 THROUGH #8 AND ELIMINATE
NORTH COURTYARD. SEE SHEET A-101.1.
BID DEDUCT ALTERNATE #10
ALL WORK IN CONTRACT EXCEPT DEDUCT #1 THROUGH #9 AND REDUCE
LANDSCAPING, TREE, AND SHRUB CALIPERS. SEE SHEET A-101.1.
BID DEDUCT ALTERNATE #11
ALL WORK IN CONTRACT EXCEPT DEDUCT #1 THROUGH #10 AND ELIMINATE
THIRD CHILLER, INCLUDING ASSOCIATED BREAKER, DISCONNECT, AND
WIRING. SEE SHEET E-401.
BID DEDUCT ALTERNATE #12
ALL WORK IN CONTRACT EXCEPT DEDUCT #1 THROUGH #11 AND MOVE
CEILING LIFTS TO ACTIVATION BUDGET. SEE SHEET A-104.1.
BID DEDUCT ALTERNATE #13
ALL WORK IN CONTRACT EXCEPT DEDUCT #1 THROUGH #12 AND PLACE
WINDOW SHADES IN THE ACTIVATION BUDGET.
BID DEDUCT ALTERNATE #14
ALL WORK IN CONTRACT EXCEPT DEDUCT #1 THROUGH #13 AND ELIMINATE
WINDOW SOFFITS AND SOLID SURFACE SILLS. SEE SHEET A-512 DETAIL 10.
BID DEDUCT ALTERNATE #15
ALL WORK IN CONTRACT EXCEPT DEDUCT #1 THROUGH #14 AND SHELL FIVE
RESIDENT ROOMS. INSTALL ELECTRICAL WIRING, BOXES, SWITCHES AS
SHOWN, EXCLUDING LIGHT FIXTURES C1 AND D2. INSTALL LIGHT FIXTURE F1
AND CIRCUIT TO WALL SWITCH PER DETAIL 5/E-401. SEE SHEET EL101.
BID DEDUCT ALTERNATE #16
ALL WORK IN CONTRACT EXCEPT DEDUCT #1 THROUGH #15 AND ELIMINATE
BENCHES. SEE SHEET A-101.1.
# ALTERNATE NOTES
2 HOUR FIRE SEPARATION
1 HOUR FIRE SEPARATION
SMOKE RATED
NOTE:
1. ALL EXPOSED PIPING SHALL BE PAINTED RED.
2. PROVIDE GUARDS ON UPRIGHT SPRINKLERS
UNLESS OTHERWISE NOTED.
THREADED
HANGER ROD
SURGE
RESTRAINER
ADJUSTABLE
RING HANGER
BRANCHLINE
AUTO. SPRINKLER FEED
UPRIGHT AUTOMATIC
SPRINKLER, FM APPROVED,
QUICK RESPONSE.
REDUCER
RISER NIPPLE
REDUCING TEE
FIRE PROTECTION WATER
SUPPLY DEMAND ESTIMATE
DESIGN DATA:
SYSTEM TYPE: WET
OCCUPATION CLASSIFICATION: ORD. GR. 1
DENSITY: 0.15 GPM/FT2
AREA OF APPLICATION: 1500
MINIMUM SPRINKLER DEMAND: 225 GPM
HOSE STREAM DEMAND: 250 GPM
OVERFLOW FACTOR (10%): 22.5 GPM
TOTAL WATER REQUIRED
(INCLUDING HOSE STREAMS): 497.5 GPM
PRIMARY OCCUPANCY: BUSINESS
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1
/2
:5
:2
P
M C
R e v it p ro je c ts
\M P
-0
-V
A J a c k s o n -C o n s tr u c t
C L
C R tb u d a i.
rv t
FX001
FIRE SUPPRESSION GENERAL
INFORMATION
1 5TB
CLC RESIDENTIAL
NEIGHBORHOOD
G.V. MONTGOMERY VAMC
1500 E. WOODROW WILSON AVENUE
JACKSON, MS 39216 JUNE 23, 2025
100% CONSTRUCTION DOCUMENTS
586-40123-060
7A
WRS
Scale: No Scale
MECHANICAL TEE AND FLUSHING CONNECTION DETAIL
Scale: No Scale
PIPE HANGER SUPPORT DETAIL
Scale: No Scale
SPRINKLER ABOVE AND BELOW DUCT DETAIL
Scale: No Scale
SPRINKLER PIPE SLEEVE THRU FIRE RATED WALL DETAIL
Scale: No Scale
SEMI-RECESSED PENDENT SPRINKLER DETAIL
WALL RATING LEGEND
Scale: No Scale
UPRIGHT AUTOMATIC SPRINKLER DETAIL
Docusign Envelope ID: F0685764-3D35-4365-8C23-542E69C17E6F
FOYER
G101
VESTIBULE
G100
BEDROOM
G148
BEDROOM
G149
BEDROOM
G150 BEDROOM
G151
BEDROOM
G152
BEDROOM
G153
BEDROOM
G142
BEDROOM
G143
BEDROOM
G144
BEDROOM
G145
BEDROOM
G146
BEDROOM, BARIATRIC
G141
BATH SUITE
G154
BEDROOM, BARIATRIC
G161
SOILED UTILITY
G174
CLEAN UTILITY
G173
BEDROOM
G172
BEDROOM
G171
SIM.G165
BEDROOM
G170
BEDROOM
G165
BEDROOM
G164
BEDROOM
G163BEDROOM
G162
FAMILY
LOUNGE
G107
MEDICINE STORAGE
G106
TELECOM CLOSET
G113
CONCIERGE STATION
G105
SITTING AREA
G104
MILTI-PURPOSE AREA
G112
LAUNDRY
G109
TOILET
G148.1 TOILET
G149.1
TOILET
G150.1
TOILET
G151.1
TOILET
G152.1
TOILET
G153.1
TOILET
G146.1
TOILET
G145.1
TOILET
G144.1
TOILET
G143.1
TOILET
G142.1 TOILET
G141.1
TOILET
G165.1
TOILET
G164.1TOILET
G163.1
TOILET
G162
TOILET
G161.1
STORAGE
G140.1
CORRIDOR
G140 CORRIDOR
G160
STAIRS
G147
STAIRS
G133
LOBBY
G103
OXYGEN
STORAGE
- EMPTY
G121
STORAGE
G140.2
ELEC
G160.2
ALCOVE
G160.5
TOILET
G172.1
TOILET
G171.1
TOILET
G170.1
G103
ELEVATOR
C1-G
ELEVATOR
C2-G
STORAGE/LINEN STORAGE
G110
KITCHEN
G111
ALCOVE
G140.5
ELEC CLOSET
G140.4
STORAGE
G140.3
MULTI-PURPOSE AREA
G102
OXYGEN
STORAGE
- FULL
G121.1
PUBLIC TOILET
G108
CLOSET
G114
UPUP
DN
DNUP
UP
3'
4'
FOYER
G101
VESTIBULE
G100
BEDROOM
G148
BEDROOM
G149
BEDROOM
G150 BEDROOM
G151
BEDROOM
G152
BEDROOM
G153
BEDROOM
G142
BEDROOM
G143
BEDROOM
G144
BEDROOM
G145
BEDROOM
G146
BEDROOM, BARIATRIC
G141
BATH SUITE
G154
BEDROOM, BARIATRIC
G161
SOILED UTILITY
G174
CLEAN UTILITY
G173
BEDROOM
G172
BEDROOM
G171
SIM.G165
BEDROOM
G170
BEDROOM
G165
BEDROOM
G164
BEDROOM
G163BEDROOM
G162
FAMILY
LOUNGE
G107
MEDICINE STORAGE
G106
TELECOM CLOSET
G113
CONCIERGE STATION
G105
SITTING AREA
G104
MILTI-PURPOSE AREA
G112
LAUNDRY
G109
TOILET
G148.1 TOILET
G149.1
TOILET
G150.1
TOILET
G151.1
TOILET
G152.1
TOILET
G153.1
TOILET
G146.1
TOILET
G145.1
TOILET
G144.1
TOILET
G143.1
TOILET
G142.1 TOILET
G141.1
TOILET
G165.1
TOILET
G164.1TOILET
G163.1
TOILET
G162
TOILET
G161.1
STORAGE
G140.1
CORRIDOR
G140 CORRIDOR
G160
STAIRS
G147
STAIRS
G133
LOBBY
G103
OXYGEN
STORAGE
- EMPTY
G121
STORAGE
G140.2
ELEC
G160.2
ALCOVE
G160.5
TOILET
G172.1
TOILET
G171.1
TOILET
G170.1
G103
ELEVATOR
C1-G
ELEVATOR
C2-G
STORAGE/LINEN STORAGE
G110
KITCHEN
G111
ALCOVE
G140.5
ELEC CLOSET
G140.4
STORAGE
G140.3
MULTI-PURPOSE AREA
G102
OXYGEN
STORAGE
- FULL
G121.1
PUBLIC TOILET
G108
CLOSET
G114
UPUP
DN
DNUP
UP
3'
4'
S S
S S
S S
S S
S
S
S SS SS SS S
S
S
S S
S
S S
S S
S S
S
S
S S
S S
S S
S S
A UT
0.K
R
0.J
PO
0.H
N
0.G
MKJ
0.F
H
0.E
GF
0.D
ED
0.C
C
0.B
B
0.A
0.5
0.4
0.3
0.2
EQUIP
CLEAN
LINEN
SOILED
HOLD
RESIDENT
TOILET
114A
RESIDENT
TOILET
113A
RESIDENT
TOILET
112A
RESIDENT
TOILET
111A
RESIDENT
TOILET
110A
RESIDENT
TOILET
109A
RESIDENT
TOILET
108A
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
SCREENED
PORCH
SUN ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
MECHANICAL
RESIDENT
TOILET
105A
RESIDENT
TOILET
106A
RESIDENT
TOILET
107A
EXISTING 4"
FS RISER
2 1/2" FS 2 1/2" FS 2 1/2" FS
F S
F S
2 1/2" FS
F S
FS
F S
FS 4" FSFSFSFS
2 1
NURSE
2 1/2" FS
SMOKE COMPARTMENT G-3
EXISTING: 5,713 SF
SMOKE COMPARTMENT G-2
EXISTING SF: 10,815
SMOKE COMPARTMENT G-1
EXISTING: 6,645 SF
1/
F S
F S
F S
4" FS
SMOKE COMPARTMENT NEW:
NEW SF: 10,570
L S
0.1
ELEC
SEATING
SEATING
LIVING
ROOM
CORRIDOR
SEATING
CORRIDOR
SCOPE OF WORK LEGEND
EXISTING SMOKE COMPARTMENT
NOT IN SCOPE
IN SCOPE
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1
/2
:5
:3
P
M C
R e v it p ro je c ts
\M P
-0
-V
A J a c k s o n -C o n s tr u c t
C L
C R tb u d a i.
rv t
FX101
GROUND FLOOR FIRE SUPPRESSION
PLAN
2 5TB
CLC RESIDENTIAL
NEIGHBORHOOD
G.V. MONTGOMERY VAMC
1500 E. WOODROW WILSON AVENUE
JACKSON, MS 39216 JUNE 23, 2025
100% CONSTRUCTION DOCUMENTS
586-40123-060
7A
WRS
Scale: 1/8" = 1'-0"
GROUND FLOOR FIRE SUPPRESSION PLAN
1 THIS ROOM SHALL BE CONSIDERED ORDINARY
HAZARD, GROUP 1.
2 THIS ROOM SHALL BE CONSIDERED ORDINARY
HAZARD, GROUP 2.
3 CONNECT NEW FIRE SPRINKLER LINE TO THE 4"
EXISTING FIRE SPRINKLER RISER IN THE GROUND
FLOOR CEILING. PROVIDE NEW FIRE SPRINKLER
ZONE, NEW ZONE VALVE, AND TAMPER SWITCH.
PERFORM HYDRAULIC CALCULATIONS. REFER T0
HYDRANT FLOW TEST DATA ON SHEET FX001.
0 4 8 16
N O
R T
H
A. PROVIDE NEW SPRINKLERS HEADS AS PER
NEW LAYOUT.
B. PROVIDE NEW MAINS FOR THE NEW ADDITION,
AND NEW BRANCH PIPING AS REQUIRED FOR
NEW LAYOUT.
C. EXISTING FIRE AND SMOKE ZONES SHALL BE
MAINTAINED.
D. UNLESS OTHERWISE NOTED, SPACES ARE
LIGHT HAZARD CLASSIFICATION.
E. FOR HAZARD CLASSIFICATION REFER TO
SPECIFICATIONS.
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
VESTIBULE
G100
BEDROOM
G148
BEDROOM
G149
BEDROOM
G150 BEDROOM
G151
BEDROOM
G152
BEDROOM
G153
BEDROOM
G142
BEDROOM
G143
BEDROOM
G144
BEDROOM
G145
BEDROOM
G146
BEDROOM, BARIATRIC
G141
BATH SUITE
G154
BEDROOM, BARIATRIC
G161
SOILED UTILITY
G174
CLEAN UTILITY
G173
BEDROOM
G172
BEDROOM
G171
SIM.G165
BEDROOM
G170
BEDROOM
G165
BEDROOM
G164
BEDROOM
G163BEDROOM
G162
FAMILY
LOUNGE
G107
MEDICINE STORAGE
G106
TELECOM CLOSET
G113
CONCIERGE STATION
G105
SITTING AREA
G104
MILTI-PURPOSE AREA
G112
LAUNDRY
G109
TOILET
G148.1 TOILET
G149.1
TOILET
G150.1
TOILET
G151.1
TOILET
G152.1
TOILET
G153.1
TOILET
G146.1
TOILET
G145.1
TOILET
G144.1
TOILET
G143.1
TOILET
G142.1 TOILET
G141.1
TOILET
G165.1
TOILET
G164.1TOILET
G163.1
TOILET
G162
TOILET
G161.1
STORAGE
G140.1
CORRIDOR
G140 CORRIDOR
G160
STAIRS
G147
STAIRS
G133
LOBBY
G103
OXYGEN
STORAGE
- EMPTY
G121
STORAGE
G140.2
ELEC
G160.2
ALCOVE
G160.5
TOILET
G172.1
TOILET
G171.1
TOILET
G170.1
G103
ELEVATOR
C1-G
ELEVATOR
C2-G
STORAGE/LINEN STORAGE
G110
KITCHEN
G111
ALCOVE
G140.5
ELEC CLOSET
G140.4
STORAGE
G140.3
MULTI-PURPOSE AREA
G102
OXYGEN
STORAGE
- FULL
G121.1
PUBLIC TOILET
G108
CLOSET
G114
UPUP
DN
DNUP
UP
3'
4'
FOYER
G101
VESTIBULE
G100
BEDROOM
G148
BEDROOM
G149
BEDROOM
G150 BEDROOM
G151
BEDROOM
G152
BEDROOM
G153
BEDROOM
G142
BEDROOM
G143
BEDROOM
G144
BEDROOM
G145
BEDROOM
G146
BEDROOM, BARIATRIC
G141
BATH SUITE
G154
BEDROOM, BARIATRIC
G161
SOILED UTILITY
G174
CLEAN UTILITY
G173
BEDROOM
G172
BEDROOM
G171
SIM.G165
BEDROOM
G170
BEDROOM
G165
BEDROOM
G164
BEDROOM
G163BEDROOM
G162
FAMILY
LOUNGE
G107
MEDICINE STORAGE
G106
TELECOM CLOSET
G113
CONCIERGE STATION
G105
SITTING AREA
G104
MILTI-PURPOSE AREA
G112
LAUNDRY
G109
TOILET
G148.1 TOILET
G149.1
TOILET
G150.1
TOILET
G151.1
TOILET
G152.1
TOILET
G153.1
TOILET
G146.1
TOILET
G145.1
TOILET
G144.1
TOILET
G143.1
TOILET
G142.1 TOILET
G141.1
TOILET
G165.1
TOILET
G164.1TOILET
G163.1
TOILET
G162
TOILET
G161.1
STORAGE
G140.1
CORRIDOR
G140 CORRIDOR
G160
STAIRS
G147
STAIRS
G133
LOBBY
G103
OXYGEN
STORAGE
- EMPTY
G121
STORAGE
G140.2
ELEC
G160.2
ALCOVE
G160.5
TOILET
G172.1
TOILET
G171.1
TOILET
G170.1
G103
ELEVATOR
C1-G
ELEVATOR
C2-G
STORAGE/LINEN STORAGE
G110
KITCHEN
G111
ALCOVE
G140.5
ELEC CLOSET
G140.4
STORAGE
G140.3
MULTI-PURPOSE AREA
G102
OXYGEN
STORAGE
- FULL
G121.1
PUBLIC TOILET
G108
CLOSET
G114
UPUP
DN
DNUP
UP
3'
4'
S S
S S
S S
S S
S
S
S SS SS SS S
S
S
S S
S
S S
S S
S S
S
S
S S
S S
S S
S S
A UT
0.K
R
0.J
PO
0.H
N
0.G
MKJ
0.F
H
0.E
GF
0.D
ED
0.C
C
0.B
B
0.A
0.5
0.4
0.3
0.2
L S
0.1
EQUIP
CLEAN
LINEN
SOILED
HOLD
RESIDENT
TOILET
114A
RESIDENT
TOILET
113A
RESIDENT
TOILET
112A
RESIDENT
TOILET
111A
RESIDENT
TOILET
110A
RESIDENT
TOILET
109A
RESIDENT
TOILET
108A
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
SCREENED
PORCH
SUN ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
MECHANICAL
RESIDENT
TOILET
105A
RESIDENT
TOILET
106A
RESIDENT
TOILET
107A
EXISTING 4"
FS RISER
2 1/2" FS 2 1/2" FS 2 1/2" FS
F S
F S
2 1/2" FS
F S
FS
F S
FS 4" FSFSFS
2 1
NURSE
2 1/2" FS
SMOKE COMPARTMENT G-3
EXISTING: 5,713 SF
SMOKE COMPARTMENT G-2
EXISTING SF: 10,815
SMOKE COMPARTMENT G-1
EXISTING: 6,645 SF
1/
F S
F S
F S
4" FS
SMOKE COMPARTMENT NEW:
NEW SF: 10,570
ELEC
SEATING
SEATING
LIVING
ROOM
CORRIDOR
SEATING
CORRIDOR
SCOPE OF WORK LEGEND
EXISTING SMOKE COMPARTMENT
NOT IN SCOPE
IN SCOPE
DEDUCT ALTERNATE NOTES
GC TO REFER TO DEDUCT ALTERNATE LIST ON
SHEET FX001 AND COORDINATE ACCORDINGLY. #
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1
/2
:5
:3
P
M C
R e v it p ro je c ts
\M P
-0
-V
A J a c k s o n -C o n s tr u c t
C L
C R tb u d a i.
rv t
FX101.1
GROUND FLOOR FIRE SUPPRESSION
PLAN - DEDUCT ALTERNATE
3 5TB
CLC RESIDENTIAL
NEIGHBORHOOD
G.V. MONTGOMERY VAMC
1500 E. WOODROW WILSON AVENUE
JACKSON, MS 39216 JUNE 23, 2025
100% CONSTRUCTION DOCUMENTS
586-40123-060
7A
WRS
Scale: 1/8" = 1'-0"
GROUND FLOOR FIRE SUPPRESSION PLAN - DEDUCT ALTERNATE 0 4 8 16
N O
R T
H
A. PROVIDE NEW SPRINKLERS HEADS AS PER
NEW LAYOUT.
B. PROVIDE NEW MAINS FOR THE NEW ADDITION,
AND NEW BRANCH PIPING AS REQUIRED FOR
THE NEW LAYOUT.
C. EXISTING FIRE AND SMOKE ZONES SHALL BE
MAINTAINED.
D. UNLESS OTHERWISE NOTED, SPACES ARE
LIGHT HAZARD CLASSIFICATION.
E. FOR HAZARD CLASSIFICATION REFER TO
SPECIFICATIONS.
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
1 THIS ROOM SHALL BE CONSIDERED ORDINARY
HAZARD, GROUP 1.
2 THIS ROOM SHALL BE CONSIDERED ORDINARY
HAZARD, GROUP 2.
3 CONNECT NEW FIRE SPRINKLER LINE TO THE 4"
EXISTING FIRE SPRINKLER RISER IN THE GROUND
FLOOR CEILING. PROVIDE NEW FIRE SPRINKLER
ZONE, NEW ZONE VALVE, AND TAMPER SWITCH.
PERFORM HYDRAULIC CALCULATIONS. REFER T0
HYDRANT FLOW TEST DATA ON SHEET FX001.
J
J
J
A UT
0.K
R
0.J
PO
0.H
N
0.G
MKJ
0.F
H
0.E
GF
0.D
ED
0.C
C
0.B
B
0.A
0.5
0.4
0.3
0.2
EQUIP
CLEAN
LINEN
SOILED
HOLD
RESIDENT
TOILET
114A
RESIDENT
TOILET
113A
RESIDENT
TOILET
112A
RESIDENT
TOILET
111A
RESIDENT
TOILET
110A
RESIDENT
TOILET
109A
RESIDENT
TOILET
108A
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
SCREENED
PORCH
SUN ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
MECHANICAL
RESIDENT
TOILET
105A
RESIDENT
TOILET
106A
RESIDENT
TOILET
107A
1 TYP.
L S
0.1
LIVING
ROOM
NURSE
SEATING
SEATING
SEATING
LIVING
ROOM
CORRIDOR
TYP.
SCOPE OF WORK LEGEND
IN SCOPE
NOT IN SCOPE
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1
/2
:5
:3
P
M C
R e v it p ro je c ts
\M P
-0
-V
A J a c k s o n -C o n s tr u c t
C L
C R tb u d a i.
rv t
FX102
GROUND FLOOR FIRE SUPPRESSION
REFLECTED CEILING PLAN
4 5TB
CLC RESIDENTIAL
NEIGHBORHOOD
G.V. MONTGOMERY VAMC
1500 E. WOODROW WILSON AVENUE
JACKSON, MS 39216 JUNE 23, 2025
100% CONSTRUCTION DOCUMENTS
586-40123-060
7A
WRS
Scale: 1/8" = 1'-0"
GROUND FLOOR FIRE SUPPRESSION REFLECTED CEILING PLAN
1 PROVIDE NEW SEMI-RECESSED QUICK RESPONSE
SPRINKLER HEADS PER NEW LAYOUT. SEE DETAIL
6/FX001.
2 PROVIDE NEW UPRIGHT SPRINKLER HEADS PER
NEW LAYOUT. SEE DETAIL 5/FX001.
0 4 8 16
N O
R T
H
A. PROVIDE NEW SPRINKLERS HEADS AS PER
NEW LAYOUT.
B. PROVIDE NEW MAINS FOR THE NEW ADDITION,
AND NEW BRANCH PIPING AS REQUIRED FOR
THE NEW LAYOUT. SEE FX101.
C. EXISTING FIRE AND SMOKE ZONES SHALL BE
MAINTAINED.
D. ALL AIR TERMINALS AND LIGHTING FIXTURES
ARE SHOWN FOR COORDINATION PURPOSES
ONLY. REFER TO THE CORRESPONDING
MECHANICAL AND ELECTRICAL DRAWINGS FOR
MORE INFORMATION.
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
J
J
A UT
0.K
R
0.J
PO
0.H
N
0.G
MKJ
0.F
H
0.E
GF
0.D
ED
0.C
C
0.B
B
0.A
0.5
0.4
0.3
0.2
L S
0.1
EQUIP
CLEAN
LINEN
SOILED
HOLD
RESIDENT
TOILET
114A
RESIDENT
TOILET
113A
RESIDENT
TOILET
112A
RESIDENT
TOILET
111A
RESIDENT
TOILET
110A
RESIDENT
TOILET
109A
RESIDENT
TOILET
108A
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
SUN ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
MECHANICAL
RESIDENT
TOILET
105A
RESIDENT
TOILET
106A
RESIDENT
TOILET
107A
1 TYP.
LIVING
ROOM
NURSE
SEATING
SEATING
SEATING
LIVING
ROOM
CORRIDOR
TYP.
SCOPE OF WORK LEGEND
IN SCOPE
NOT IN SCOPE
DEDUCT ALTERNATE NOTES
GC TO REFER TO DEDUCT ALTERNATE LIST ON
SHEET FX001 AND COORDINATE ACCORDINGLY. #
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1
/2
:5
:4
P
M C
R e v it p ro je c ts
\M P
-0
-V
A J a c k s o n -C o n s tr u c t
C L
C R tb u d a i.
rv t
FX102.1
GROUND FLOOR FIRE SUPPRESSION
REFLECTED CEILING PLAN - DEDUCT
ALTERNATE
5 5TB
CLC RESIDENTIAL
NEIGHBORHOOD
G.V. MONTGOMERY VAMC
1500 E. WOODROW WILSON AVENUE
JACKSON, MS 39216 JUNE 23, 2025
100% CONSTRUCTION DOCUMENTS
586-40123-060
7A
WRS
Scale: 1/8" = 1'-0"
GROUND FLOOR FIRE SUPPRESSION REFLECTED CEILING PLAN - DEDUCT ALTERNATE 0 4 8 16
N O
R T
H
A. PROVIDE NEW SPRINKLERS HEADS AS PER
NEW LAYOUT.
B. PROVIDE NEW MAINS FOR THE NEW ADDITION,
AND NEW BRANCH PIPING AS REQUIRED FOR
THE NEW LAYOUT. SEE FX101.1.
C. EXISTING FIRE AND SMOKE ZONES SHALL BE
MAINTAINED.
D. ALL AIR TERMINALS AND LIGHTING FIXTURES
ARE SHOWN FOR COORDINATION PURPOSES
ONLY. REFER TO THE CORRESPONDING
MECHANICAL AND ELECTRICAL DRAWINGS FOR
MORE INFORMATION.
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
1 PROVIDE NEW SEMI-RECESSED QUICK RESPONSE
SPRINKLER HEADS PER NEW LAYOUT. SEE DETAIL
6/FX001.
2 PROVIDE NEW UPRIGHT SPRINKLER HEADS PER
NEW LAYOUT. SEE DETAIL 5/FX001.
3 IN DEDUCT AREA PROVIDE NEW UPRIGHT
SPRINKLER HEADS PER NEW LAYOUT FOR
DEDUCT #15 ONLY.
S SS
DCWR
DHW
PIPING SYSTEM
NG NATURAL GAS
ST STORM
PD PUMP DISCHARGE
OFD OVERFLOW STORM DRAIN
GW GREASE WASTE
OW OIL WASTE
SAN SANITARY WASTE
D CONDENSATE DRAIN
CA COMPRESSED AIR
AW ACID WASTE
N2 NITROGEN
N2O NITROUS OXIDE
MA MEDICAL AIR
O2 OXYGEN
WAGD WASTE ANESTHETIC GAS DISPOSAL
VAC VACUUM
V SANITARY VENT
OV OIL VENT
AV ACID VENT
NPCW NONPOTABLE COLD WATER
DI DE-IONIZED WATER
DSCW DOMESTIC SOFT COLD WATER
DCW DOMESTIC COLD WATER
RO REVERSE OSMOSIS WATER
DOMESTIC CW RECIRCULATION
DOMESTIC HOT WATER
CO2 CARBON DIOXIDE
DHW 140 DOMESTIC HOT WATER (OTHER TEMP)
PG PROPANE GAS
DHWR DOMESTIC HW RECIRCULATION
NG
ST
PD
OFD
GW
OW
SAN
D
CA
AW
N2
N2O
MA
O2
WAGD
VAC
CO2
PG
V
OV
AV
HW 140
DSCW
NPCW
DI
RO
EXISTING
NEW WORK KEYNOTE
DEMOLITION KEYNOTE
NEW BOLD TEXT INDICATES NEW ITEM
ITALICIZED TEXT INDICATES EXISTING ITEM
NEW PLUMBING EQUIPMENT MARK
DETAIL OR SECTION MARK
SHOWN ON DRAWING
DETAIL MODULE NUMBER
CONNECT TO EXISTING
LIMIT OF DEMOLITION
P-###
EXISTING PLUMBING EQUIPMENT MARKP-###
3-WAY CONTROL VALVE
ANGLE GATE VALVE
ANGLE GLOBE VALVE
BALL VALVE
BUTTERFLY VALVE
CHECK VALVE
CONTROL VALVE
GATE VALVE
GLOBE VALVE
SAFETY RELIEF VALVE
TWO POSITION CONTROL VALVE
BACKFLOW PREVENTER
ECCENTRIC REDUCER
CONCENTRIC REDUCER
FLOW ARROW
HOSE BIBB / SILLCOCK
PLUG VALVE
PRESSURE REDUCING VALVE (WATER)
PRESSURE REGULATOR (GAS)
PIPE ANCHOR
PIPE GUIDES
WALL CLEANOUT
SUSPENDED CLEANOUT
WCO
WYE STRAINER
WYE STRAINER WITH DRAIN VALVE
FLOOR DRAIN - ROUND OR SQUARE
FLOOR CLEANOUT
PIPE CAP
PIPE TURNING DOWN
PIPE TURNING UP
TEE UP
TEE DOWN
DROP AND RUN
DROP AND TURN
TEE OFF TOP
TEE OFF BOTTOM
CROSS AND RISER
PLAN 90° ELBOW
PIPE TEE
PIPE UNION
FLEXIBLE PIPE CONNECTOR
WATER METER
PUMP
AUTOMATIC AIR VENT
PRESSURE SWITCH
PRESSURE GAUGE
THERMOMETER
FLOW SWITCH
TEMPERATURE SWITCH
OR
CO
PIPE SLOPE ARROW
AV
F
P
T
M
CIRCUIT SETTER
F FAHRENHEIT
FA FROM ABOVE
FB FROM BELOW
FBO FURNISHED BY OTHERS
FCO FLOOR CLEANOUT
FCW FILTERED COLD WATER
FD FLOOR DRAIN
FDC FIRE DEPARTMENT (HOSE)
CONNECTION
FM FLOW METER
FOP FUEL OIL PUMP
FOR FUEL OIL RETURN
FOS FUEL OIL SUPPLY
FOV FUEL OIL VENT
FS FLOOR SINK
FU FIXTURE UNITS
G GALLON
GC GENERAL CONTRACTOR
GCO GRADE CLEANOUTS
GD GARBAGE DISPOSAL
GPD GALLONS PER DAY
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GPR GAS PRESSURE REGULATOR
GRS GAS REGULATOR STATION
GT GREASE TRAP
GVTR GAS VENT THROUGH ROOF
GWH GAS FIRED WATER HEATER
H&CW HOT AND COLD WATER
HB HOSE BIBB (INTERIOR)
HD HUB DRAIN
HEX HEAT EXCHANGER
HP HORSEPOWER
HS HAND SINK
HST HOT WATER STORAGE TANK
(DOMESTIC)
HWB HOT WATER BOILER
HWCP HOT WATER CIRCULATING PUMP
HWP HOT WATER PUMP
HYD HYDRANT
ICW INDUSTRIAL COLD WATER
INV INVERT
IPC INTERNATIONAL PLUMBING CODE
IRW IRRIGATION WATER
IW INDIRECT WASTE
IWH INSTANTANEOUS WATER HEATER
IWR INDUSTRIAL WATER RETURN
IWS INDUSTRIAL WATER SUPPLY
KW KILOWATT
KWHR KILOWATT-HOUR
L/S LITER PER SECOND
LA LABORATORY AIR
LAV LAVATORY
LBS/HR POUNDS PER HOUR
LCW LABORATORY COLD WATER
LHW LABORATORY HOT WATER
LNG LIQUID NATURAL GAS
LOX LIQUID OXYGEN
LV LABORATORY VACUUM
LW LOW WATER
M METER
MA MEDICAL AIR
MAV MANUAL AIR VENT
MBH THOUSANDS OF BTU PER HOUR
MC MECHANICAL CONTRACTOR
MED MEDICAL
MER MECHANICAL EQUIPMENT ROOM
MH MANHOLE
MOU MEMORANDUM OF UNDERSTANDING
MSB MOP SINK BASIN
MV MEDICAL VACUUM
N2 NITROGEN
N2O NITROUS OXIDE
NC NORMALLY CLOSED
NG NATURAL GAS
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NOM NOMINAL
NPW NON POTABLE WATER
NTS NOT TO SCALE
O2 OXYGEN
OC ON CENTER
OD OUTSIDE DIAMETER
OSD OVERFLOW STORM DRAIN
OR OPERATING ROOM
OVFL OVERFLOW
PA PASCAL
PC PLUMBING CONTRACTOR
PD PRESSURE DROP
PDI PLUMBING AND DRAINAGE INSTITUTE
PG PRESSURE GAUGE
PP PLUMBING PUMP
PPM PARTS PER MILLION
PRS PRESSURE REDUCING STATION
PRV PRESSURE REDUCING VALVE
PSI POUNDS PER SQUARE INCH
PSIA POUNDS PER SQUARE INCH -
ABSOLUTE
PSIG POUNDS PER SQUARE INCH - GAUGE
PTRV PRESSURE TEMPERATURE RELIEF
VALVE
PW POTABLE WATER
RD ROOF DRAIN
RDL ROOF DRAIN LEADER
RL ROOF LEADER
RO REVERSE OSMOSIS
RWL RAIN WATER LEADER
SAN SANITARY SEWER
SCFM STANDARD CUBIC FOOT/MIN
SCW SOFTENED COLD WATER
SD STORM DRAIN
SDMH STORM DRAIN MANHOLE
SP SUMP PUMP
SPR SPRINKLER LINE
SQFT SQUARE FOOT
SS STAINLESS STEEL
ST STORAGE TANK
SW STORM WATER
TCV TEMPERATURE CONTROL VALVE
TD TRENCH DRAIN
TDH TOTAL DYNAMIC HEAD
TDL TEMPERATURE DIFFERENTIAL
TEMP TEMPERATURE
TMV THERMOSTATIC MIXING VALVE
TP TRAP PRIMER
TSTAT THERMOSTAT
TWR TEMPERED WATER RETURN
TWS TEMPERED WATER SUPPLY
TYP TYPICAL
UPC UNIFORM PLUMBING CODE
V SANITARY VENT
VAC VACUUM
VB VACUUM BREAKER
VCO VACUUM CLEANER OUTLET
VP VACUUM PUMP
VS VENT STACK
VTR VENT THROUGH ROOF
W WASTE
WC WATER CLOSET
WCO WALL CLEANOUT
WG WATER GAUGE
WH WATER HEATER
WHA WATER HAMMER ARRESTOR
WHD WALL HYDRANT
WL WATER LINE
WM WATER METER
WPD WATER PRESSURE DROP
WS WASTE STACK
YCO YARD CLEANOUT
YH YARD HYDRANT
A/E ARCHITECT/ENGINEER
AC ABOVE CEILING
AD AREA DRAIN
AFF ABOVE FINISHED FLOOR
AG AIR GAP
AP ACCESS PANEL
AS AUTOMATIC SPRINKLER
AFG ABOVE FINISHED GRADE
ASD ADJUSTABLE SPEED DRIVE
ASHRAE AMERICAN SOCIETY HEATING,
REFRIGERATING, AIR CONDITIONING
ENGINEERS
ASME AMERICAN SOCIETY OF MECHANICAL
ENGINEERS
ASPE AMERICAN SOCIETY PLUMBING
ENGINEERS
ASR AUTOMATIC SPRINKLER RISER
AV ACID VENT
AW ACID WASTE
BAS BUILDING AUTOMATION SYSTEM
BF BELOW FLOOR
BFP BACKFLOW PREVENTER
BG BELOW GRADE
BH BOOSTER HEATER
BHP BREAK HORSEPOWER
BJ BETWEEN JOISTS
BOP BOTTOM OF PIPE
BSP BLACK STEEL PIPE
BT BATHTUB
BTUH BRITISH THERMAL UNITS PER HOUR
C CELSIUS
CF COMBINATION FIXTURE
CGA COMPRESSED GAS ASSOCIATION
CI CAST IRON
CO CLEANOUT
COND CONDENSATE
CP CONDENSATE PUMP
CS CLINICAL SINK
CV CONTROL VALVE
DA DENTAL COMPRESSED AIR
DCW DOMESTIC COLD WATER
DHW DOMESTIC HOT WATER
DHWR DOMESTIC HOT WATER RETURN
DHWS DOMESTIC HOT WATER SUPPLY
DF DRINKING FOUNTAIN
DI DEIONIZED WATER
DN DOWN
DOE DEPARTMENT OF ENERGY
DS DOWNSPOUT
DV DENTAL VACUUM
DW DISHWASHER
DWG DRAWING
DWH DOMESTIC WATER HEATER
DWR DRINKING WATER RETURN
DWS DRINKING WATER SUPPLY
DWT DOMESTIC WATER TEMPERED
DWV DRAIN WASTE VENT
EC ELECTRICAL CONTRACTOR
EL ELEVATION
EMCS ENERGY MONOSERRAT AND CENTRAL
SYSTEM
EPA ENVIRONMENTAL PROTECTION
AGENCY
EPACT ENERGY POLICY ACT
ESC ESCUTCHEON
ESH EMERGENCY SHOWER
ET EXPANSION TANK
EWC ELECTRIC WATER COOLER
EWH ELECTRIC WATER HEATER
EWS EYEWASH STATION
EX EXISTING
PLUMBING SYMBOLS PLUMBING SYMBOLS
ANNOTATION SYMBOLS
PLUMBING ABBREVIATIONS
DWT DOMESTIC WATER TEMPERED DWT
DCW DOMESTIC CW BELOW THE FLOOR
SD STORM BELOW THE FLOOR
SAN SANITARY WASTE BELOW THE FLOOR
1. WORK SHALL CONFORM TO APPLICABLE LOCAL, STATE, AND NATIONAL CODES AND APPLICABLE VA STANDARDS.
2. INSTALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S WRITTEN RECOMMENDATIONS.
3. OBTAIN AND PAY FOR PERMITS, FEES, AND INSPECTIONS REQUIRED FOR THIS WORK.
4. PROVIDE NEW MATERIALS, EQUIPMENT AND PRODUCTS INCORPORATED IN THE WORK, OF A SUITABLE GRADE FOR THE
PURPOSES INTENDED.
5. EQUIPMENT OR MATERIAL DEVIATIONS FROM INDICATED CONTRACT REQUIREMENTS ARE SUBJECT TO THE APPROVAL OF THE COR. SUBMIT PROPOSED EQUIPMENT DEVIATIONS THAT ARE SIMILAR BOTH IN QUALITY AND CAPACITY TO THAT
EQUIPMENT SPECIFIED, AS SOLELY DETERMINED BY THE COR.
6. INSTALL EQUIPMENT AS INDICATED, ALLOWING FOR SUFFICIENT ACCESS AND CLEARANCE SPACE FOR EQUIPMENT
MAINTENANCE, REPAIRS, AND REPLACEMENT.
7. AT EACH PLUMBING FIXTURE WITH QUICK CLOSING VALVES, PROVIDE A PISTON TYPE WATER HAMMER ARRESTOR SIZED
ACCORDING TO MANUFACTURER'S RECOMMENDATIONS.
8. SANITARY DRAINAGE PIPING INDICATED IS LOCATED BELOW FLOOR SLAB OR WITHIN WALLS UNLESS NOTED OTHERWISE.
SANITARY VENT PIPING INDICATED IS ABOVE THE CEILING OR WITHIN WALLS UNLESS NOTED OTHERWISE.
9. SUPPORT PIPING SYSTEM AS REQUIRED BY APPLICABLE LOCAL, STATE, AND NATIONAL CODES ALONG WITH
SPECIFICATIONS, VA STANDARDS AND MANUFACTURER'S RECOMMENDATIONS.
10. FIRESTOP AND SEAL PIPING PENETRATIONS THROUGH WALLS AND FLOORS EQUAL TO THE RATING OF WALLS AND FLOORS.
11. TEST PLUMBING SYSTEM IN ACCORDANCE WITH APPLICABLE LOCAL, STATE AND NATIONAL CODES AND APPLICABLE VA
STANDARDS.
12. COORDINATE PLUMBING PIPING WITH WORK OF OTHER DISCIPLINES.
13. DISINFECT DOMESTIC WATER SYSTEM IN ACCORDANCE WITH APPLICABLE LOCAL, STATE, AND NATIONAL CODES AND
APPLICABLE VA STANDARDS.
14. PROVIDE SHUT OFF VALVES AT BRANCH PIPING TO FIXTURES.
15. COORDINATE PLUMBING WORK WITH ALL OTHER TRADES PRIOR TO INSTALLATION. COORDINATE ROUTING OF PIPING WITH
EXISTING CONDITIONS.
16. PROVIDE ALL NECESSARY OFFSETS, TEES, ELBOWS, ETC. FOR A COMPLETE AND COORDINATED WORKING PLUMBING SYSTEM. DRAWING PLANS, SCHEMATICS, AND DIAGRAMS INDICATE GENERAL LOCATION AND ARRANGEMENT OF PIPING
SYSTEMS.
17. CONTRACTOR SHALL COORDINATE ANY PLUMBING SYSTEM REQUIRED SHUTDOWN WITH THE COR 2 WEEKS IN ADVANCE
AND CONFIRM 48 HOURS PRIOR.
18. PATCH, PAINT AND CLEAN SURFACES SUSTAINING DAMAGE ASSOCIATED WITH PLUMBING WORK OF THIS CONTRACT, UNLESS NOTED OTHERWISE.
19. INSTALL ESCUTCHEONS IN ALL PLACES WHERE PIPING PENETRATES A WALL IN AN EXPOSED LOCATION.
20. DO NOT INSTALL PIPES ABOVE TELECOM OR ELECTRICAL EQUIPMENT.
21. CONTRACTOR RESPONSIBLE FOR PROVIDING ALL TESTING ASSOCIATED WITH PLUMBING SYSTEM COMMISSIONING PER
SPECIFICATIONS.
PLUMBING GENERAL NOTES
BID DEDUCT ALTERNATE #1
ALL WORK IN CONTRACT EXCEPT CHANGE FENCE AND PYLONS TO METAL
FENCE. SEE SHEET A-101.1.
BID DEDUCT ALTERNATE #2
ALL WORK IN CONTRACT EXCEPT DEDUCT #1 AND SUBSTITUTE BRICK IN
PLACE OF RAINSCREEN. SEE SHEET A-201.1.
BID DEDUCT ALTERNATE #3
ALL WORK IN CONTRACT EXCEPT DEDUCT #1, #2, AND REMOVE SCREEN
SYSTEM AT FIRST-FLOOR PORCH. SEE SHEET A-201.1.
BID DEDUCT ALTERNATE #4
ALL WORK IN CONTRACT EXCEPT DEDUCT #1 THROUGH #3 AND REMOVE
SCREEN SYSTEM AT GROUND FLOOR PORCH. SEE SHEET A-201.1.
BID DEDUCT ALTERNATE #5
ALL WORK IN CONTRACT EXCEPT DEDUCT #1 THROUGH #4 AND OMIT
LANDSCAPE/HARDSCAPE IN THE SOUTHERN COURTYARD. SEE SHEET A101.1.
BID DEDUCT ALTERNATE #6
ALL WORK IN CONTRACT EXCEPT DEDUCT #1 THROUGH #5 AND ELIMINATE
SCREEN PORCH, INCLUDING ASSOCIATED LIGHT FIXTURES, LIGHTING
CONTROLS, RECEPTACLES, AND NOTIFICATION DEVICES. INSTALL LIGHT
FIXTURE M1E AT DOUBLE DOORS EXITING THE BUILDING. INSTALL PULL
STATION AT DOUBLE DOORS EXITING THE BUILDING. SEE SHEETS EL101,
EP101, AND FA101.
BID DEDUCT ALTERNATE #7
ALL WORK IN CONTRACT EXCEPT DEDUCT #1 THROUGH #6 AND ELIMINATE
LANDSCAPE LIGHTING, INCLUDING LIGHT FIXTURES AND LIGHTING CONTROLS.
SEE SHEET ES101.
BID DEDUCT ALTERNATE #8
ALL WORK IN CONTRACT EXCEPT DEDUCT #1 THROUGH #7 AND OMIT
CANOPIES. SEE SHEET A-105.
BID DEDUCT ALTERNATE #9
ALL WORK IN CONTRACT EXCEPT DEDUCT #1 THROUGH #8 AND ELIMINATE
NORTH COURTYARD. SEE SHEET A-101.1.
BID DEDUCT ALTERNATE #10
ALL WORK IN CONTRACT EXCEPT DEDUCT #1 THROUGH #9 AND REDUCE
LANDSCAPING, TREE, AND SHRUB CALIPERS. SEE SHEET A-101.1.
BID DEDUCT ALTERNATE #11
ALL WORK IN CONTRACT EXCEPT DEDUCT #1 THROUGH #10 AND ELIMINATE
THIRD CHILLER, INCLUDING ASSOCIATED BREAKER, DISCONNECT, AND
WIRING. SEE SHEET E-401.
BID DEDUCT ALTERNATE #12
ALL WORK IN CONTRACT EXCEPT DEDUCT #1 THROUGH #11 AND MOVE
CEILING LIFTS TO ACTIVATION BUDGET. SEE SHEET A-104.1.
BID DEDUCT ALTERNATE #13
ALL WORK IN CONTRACT EXCEPT DEDUCT #1 THROUGH #12 AND PLACE
WINDOW SHADES IN THE ACTIVATION BUDGET.
BID DEDUCT ALTERNATE #14
ALL WORK IN CONTRACT EXCEPT DEDUCT #1 THROUGH #13 AND ELIMINATE
WINDOW SOFFITS AND SOLID SURFACE SILLS. SEE SHEET A-512 DETAIL 10.
BID DEDUCT ALTERNATE #15
ALL WORK IN CONTRACT EXCEPT DEDUCT #1 THROUGH #14 AND SHELL FIVE
RESIDENT ROOMS. INSTALL ELECTRICAL WIRING, BOXES, SWITCHES AS
SHOWN, EXCLUDING LIGHT FIXTURES C1 AND D2. INSTALL LIGHT FIXTURE F1
AND CIRCUIT TO WALL SWITCH PER DETAIL 5/E-401. SEE SHEET EL101.
BID DEDUCT ALTERNATE #16
ALL WORK IN CONTRACT EXCEPT DEDUCT #1 THROUGH #15 AND ELIMINATE
BENCHES. SEE SHEET A-101.1.
# ALTERNATE NOTES
2 HOUR FIRE SEPARATION
1 HOUR FIRE SEPARATION
SMOKE RATED
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1
/2
:2
:4
P
M C
R e v it p ro je c ts
\M P
-0
-V
A J a c k s o n -C o n s tr u c t
C L
C R tb u d a i.
rv t
P-001
PLUMBING GENERAL INFORMATION
1 14TB
CLC RESIDENTIAL
NEIGHBORHOOD
G.V. MONTGOMERY VAMC
1500 E. WOODROW WILSON AVENUE
JACKSON, MS 39216 JUNE 23, 2025
100% CONSTRUCTION DOCUMENTS
586-40123-060
7A
WRS
WALL RATING LEGEND
VESTIBULE
G100
BEDROOM
G148
BEDROOM
G149
BEDROOM
G150 BEDROOM
G151
BEDROOM
G152
BEDROOM
G153
BEDROOM
G142
BEDROOM
G143
BEDROOM
G144
BEDROOM
G145
BEDROOM
G146
BEDROOM, BARIATRIC
G141
BATH SUITE
G154
BEDROOM, BARIATRIC
G161
SOILED UTILITY
G174
CLEAN UTILITY
G173
BEDROOM
G172
BEDROOM
G171
SIM.G165
BEDROOM
G170
BEDROOM
G165
BEDROOM
G164
BEDROOM
G163BEDROOM
G162
TELECOM CLOSET
G113
CONCIERGE STATION
G105
SITTING AREA
G104
MILTI-PURPOSE AREA
G112
TOILET
G148.1 TOILET
G149.1
TOILET
G150.1
TOILET
G151.1
TOILET
G152.1
TOILET
G153.1
TOILET
G146.1
TOILET
G145.1
TOILET
G144.1
TOILET
G143.1
TOILET
G142.1 TOILET
G141.1
TOILET
G165.1
TOILET
G164.1TOILET
G163.1
TOILET
G162
TOILET
G161.1
STORAGE
G140.1
CORRIDOR
G140 CORRIDOR
G160
STAIRS
G147
LOBBY
G103STORAGE
G140.2
ELEC
G160.2
ALCOVE
G160.5
TOILET
G172.1
TOILET
G171.1
TOILET
G170.1
G103
ELEVATOR
C1-G
ELEVATOR
C2-G
STORAGE/LINEN STORAGE
G110
KITCHEN
G111
ALCOVE
G140.5
ELEC CLOSET
G140.4
STORAGE
G140.3
MULTI-PURPOSE AREA
G102
PUBLIC TOILET
G108
CLOSET
G114
UP
3'
4'
FOYER
G101
VESTIBULE
G100
BEDROOM
G148
BEDROOM
G149
BEDROOM
G150 BEDROOM
G151
BEDROOM
G152
BEDROOM
G153
BEDROOM
G142
BEDROOM
G143
BEDROOM
G144
BEDROOM
G145
BEDROOM
G146
BEDROOM, BARIATRIC
G141
BATH SUITE
G154
BEDROOM, BARIATRIC
G161
SOILED UTILITY
G174
CLEAN UTILITY
G173
BEDROOM
G172
BEDROOM
G171
SIM.G165
BEDROOM
G170
BEDROOM
G165
BEDROOM
G164
BEDROOM
G163BEDROOM
G162
TELECOM CLOSET
G113
CONCIERGE STATION
G105
SITTING AREA
G104
MILTI-PURPOSE AREA
G112
TOILET
G148.1 TOILET
G149.1
TOILET
G150.1
TOILET
G151.1
TOILET
G152.1
TOILET
G153.1
TOILET
G146.1
TOILET
G145.1
TOILET
G144.1
TOILET
G143.1
TOILET
G142.1 TOILET
G141.1
TOILET
G165.1
TOILET
G164.1TOILET
G163.1
TOILET
G162
TOILET
G161.1
STORAGE
G140.1
CORRIDOR
G140 CORRIDOR
G160
STAIRS
G147
LOBBY
G103STORAGE
G140.2
ELEC
G160.2
ALCOVE
G160.5
TOILET
G172.1
TOILET
G171.1
TOILET
G170.1
G103
ELEVATOR
C1-G
ELEVATOR
C2-G
STORAGE/LINEN STORAGE
G110
KITCHEN
G111
ALCOVE
G140.5
ELEC CLOSET
G140.4
STORAGE
G140.3
MULTI-PURPOSE AREA
G102
PUBLIC TOILET
G108
CLOSET
G114
UP
3'
4'
S S
S S
S S
S S
S
S
S SS SS SS S
S
S
S S
S
S S
S S
S S
S
S
S S
S S
S S
S S
A UT
0.K
R
0.J
PO
0.H
N
0.G
MKJ
0.F
H
0.E
GF
0.D
ED
0.C
C
0.B
B
0.A
0.5
0.4
0.3
0.2
EQUIP
CLEAN
LINEN
SOILED
HOLD
RESIDENT
TOILET
114A
RESIDENT
TOILET
113A
RESIDENT
TOILET
112A
RESIDENT
TOILET
111A
RESIDENT
TOILET
110A
RESIDENT
TOILET
109A
RESIDENT
TOILET
108A
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
SCREENED
PORCH
SUN ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
105 MECHANICAL
RESIDENT
TOILET
105A
RESIDENT
TOILET
106A
RESIDENT
TOILET
107A
P-101*
P-413*P-413*
P-101*
P-101*
P-413*P-413*
P-101* P-101*
P-413*P-413*
P-101* P-101*
P-41…