Attachment 03 107315 Extruded Alum Canopy.pdf

PDF 21 KB Posted

Attached to
Y1DA--586-401 | Construct CLC Residential Neighborhood | Jackson, MS | Scott Tom
Solicitation number
36C77626B0023
Issued by

About this file

This is a construction specification section for extruded aluminum canopies as part of the G.V. Montgomery VAMC CLC Residential Neighborhood project in Jackson, Mississippi (Project No. 586-401), dated June 29, 2026, issued as Addendum 01.

The specification requires furnishing and installation of extruded aluminum canopy systems composed of decking, tie rods, posts, and fascia fabricated from aluminum alloy 6063-T6 according to current Mapes brochures. The canopy components must feature either a fluorocarbon finish meeting AAMA 2605 or an anodized finish meeting AAMA 611 (AA-M12C22A41) with chemically etched medium matte coating, Class I Architectural grade, 0.18 mm (7 mils) thick. Color selection will be determined by the Contracting Officer Representative (COR) and Architect from the manufacturer's full range, including metallic fluorocarbon options. The decking shall employ interlocking extruded aluminum members with field-applied mechanical fasteners to ensure structural integrity and must be designed as water-tight with proper internal drainage flow. Manufacturers and installers must each demonstrate a minimum of three years of documented experience. All components must be delivered and stored under cover and elevated above grade. The contractor must provide a five-year warranty period for corrective work after Substantial Completion, plus a five-year manufacturer warranty against exterior finish degradation including fading, chalking, or flaking, with provisions for unit and material replacement. Installation must comply strictly with manufacturer shop drawings, with erection scheduled after completion of all concrete, masonry, and roofing work in the area. Applicable reference standards include AAMA CW-10, ASCE 7, ASTM B209, and ASTM B221.

View the file

Other files

File Type Posted
Attachment 01 C - FAR Clause 52.212-4 - Construction KAE.docx DOCX document
36C77626B0023 0007.docx DOCX document
36C77626B0023 0006.docx DOCX document
Attachment 01 S05 - Tech Questions Tracker w clarifications v1.xlsx XLSX spreadsheet
Attachment 02 23-060_Addendum 02 Door Tags Locations.pdf PDF
Attachment 01 Asbestos AHERA Baseline Survey--February 2017.pdf PDF
36C77626B0023 0005.docx DOCX document
Attachment 01 S05 - Tech Questions Tracker.xlsx XLSX spreadsheet
36C77626B0023 0004.docx DOCX document
Attachment 08 M-601.pdf PDF
Attachment 07 M-504.pdf PDF
Attachment 09 A-104 Cubicle Curtains.pdf PDF
Attachment 06 M-503.pdf PDF
Attachment 05 117300 Ceiling Pt. Lift System.pdf PDF
Attachment 04 331000 Water Utilities.pdf PDF
Attachment 02 051200 StructSteelFraming.pdf PDF
36C77626B0023 0003.docx DOCX document
36C77626B0023 0002.docx DOCX document
GeoReport.VA CLC Neighborhood - Jackson MS.EB245012_locked_.pdf PDF
S04 Site Visit Sign in Sheet 36C77626B0023.pdf PDF
36C77626B0023 0001.docx DOCX document
S02 36C77626B0023_1 Final.pdf PDF
Attachment 05 Wage Determination Hinds County MS 05_28_2026.pdf PDF
Attachment 04- Limitations on Subcontracting - Construction.pdf PDF
Attachment 3 P11 Vol2 Drawings SS Final.pdf PDF
Attachment 2 P11 Vol1 Drawings SS Final.pdf PDF
Attachment 06 - Site Visit Details.docx DOCX document
Attchment 1 23-060 Specs 100 percent SS 20250618 Final.pdf PDF
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

G.V. Montgomery VAMC June 29, 2026

CLC Residential Neighborhood 100% Construction Documents

Jackson, MS 39216 Project No: 586-401

Addendum 01

10 73 15 - 1

SECTION 10 73 15

EXTRUDED ALUMINUM CANOPY

PART 1 - GENERAL

1.1 SECTION INCLUDES

A. Work in this section includes furnishing and installation of extruded aluminum canopies.

1.2 RELATED REQUIREMENTS

A. Section 01 33 23 - Product Requirements: Fundamental product requirements, substitutions and product options, delivery, storage, and handling.

B. Section 07 6000 - Sheet Metal Flashing and Trim: Flashings between canopy and adjacent finishes.

C. Section 04 2000 – Unit Masonry

D. Section 05 1200 - Structural Steel

E. Section 05 5000 - Miscellaneous Metals

F. Section 05 4000 - Cold Formed Metal Framing

1.3 REFERENCE STANDARDS

A. AAMA CW-10 - Care and Handling of Architectural Aluminum from Shop to

Site; American Architectural Manufacturers Association; 2012.

B. ASCE 7 - Minimum Design Loads for Buildings and Other Structures;

American Society of Civil Engineers; 2011.

C. ASTM B209 - Standard Specification for Aluminum and Aluminum-Alloy

Sheet and Plate; 2010.

D. ASTM B221 - Standard Specification for Aluminum and Aluminum-Alloy

Extruded Bars, Rods, Wire, Profiles, and Tubes; 2013.

1.4 SUBMITTALS

A. See Section 01 3323 - Administrative Requirements, for submittal procedures.

B. Product Data: Provide component dimensions and profiles, describe components within assembly, anchorage and fasteners, and internal drainage details.

C. Field Measurement: Confirm dimensions prior to preparation of shop drawings when possible

D. Shop Drawings: Indicate system dimensions and tolerances; affected related Work; framing members; exterior finishes; continuity of water-resistant barrier from canopy to adjacent surfaces; internal water drainage system; anchoring and attachment methods.

10 73 15 - 2

E. Samples: Submit two samples, 4x4 inch in size, illustrating finish color.

F. Delegated Design Data: Indicate compliance of canopy structure with design loads noted in Structural drawings.

1.5 QUALITY ASSURANCE

A. Manufacturer Qualifications: Company specializing in manufacturing products specified in this section, with not less than three years of documented experience.

B. Installer Qualifications: Company specializing in performing the work of this sectionwith minimum 3 years of experience.

1.6 DELIVERY, STORAGE, AND HANDLING

A. Deliver and store all canopy components under cover and elevated above grade.

1.7 WARRANTY

A. Correct defective Work within a five-year period after Date of

Substantial Completion.

B. Provide five-year manufacturer warranty against excessive degradation of exterior finish. Include provision for replacement of units and materials with excessive fading, chalking, or flaking.

PART 2 - PRODUCTS

2.1 CANOPY SYSTEM

A. Description:

1. Composition: Decking, tie rods, posts and fascia shall be extruded aluminum, alloy 6063-T6, in profile and thickness shown in current

Mapes brochures.

2. Size: As indicated on drawings

3. Finish:

a. Fluorocarbon Finish meeting AAMA 2605.

b. Anodized Finish meeting AAMA 611 (AA-M12C22A41). Chemically etched medium matte, with anodic coating, Class I Architectural,

0.18 mm (7 mils) thick.

4. Color: To be selected by COR and Architect from manufacturer’s full range including metallic fluorocarbon finishes.

B. Fabrication

10 73 15 - 3

1. Decking shall be designed with interlocking extruded aluminum members with mechanical fasteners field applied to provide structural integrity for the completed assembly.

2. Design and construct to be water-tight and have proper flow to internal drainage system.

PART 3 - EXECUTION

3.1 INSPECTION

A. Confirm that surrounding area is ready for the canopy installation.

B. Installer shall confirm dimensions and elevations to be as shown on drawings provided by manufacturer.

C. Erection shall be performed by an approved installer and scheduled after all concrete, masonry and roofing in the area is completed.

3.2 INSTALLATION

A. Installation shall be in strict accordance with manufacturer’s shop drawings. Particular attention should be given to protecting the finish during handling and erection

3.3 CLEANING

A. After installation, entire system shall be left in a clean condition.

B. Protect installed products from damage during subsequent construction.

---END---

10 73 15 - 4

--- INTENTIONALLY BLANK ---

File details come from the government source that posted it. Updated .