This is a Reflected Ceiling Plan (RCP) for the Ground Floor of a construction project at the G.V. Montgomery Veterans Affairs Medical Center (VAMC) in Jackson, Mississippi. The drawing is part of 100% Construction Documents dated June 23, 2025, with Addendum 01 issued on June 29, 2026, for Project Number 23-060 (Building 586-401).
The scope of work includes removal and replacement of existing ceiling grid and tiles, with new ceilings specified at 9'-0" Above Finished Floor (AFF) and soffits/bulkheads at 8'-0" AFF throughout the facility. The plan details placement of multiple ceiling-mounted devices including 2'x4' recessed flat lens troffers, 6" diameter recessed downlights, 4' linear suspended strips, pendant lights, exit signs, supply diffusers, return grilles, exhaust grilles, semi-recessed sprinkler heads, ceiling-mounted lifts, ceiling-mounted fans, and access panels. Key requirements include centering all lights, diffusers, exit signage, sprinkler heads, and smoke detectors within ceiling tiles; centering exit signs over doors; balancing border widths at room edges; avoiding tiles less than 6" in width; painting exposed cut edges of acoustical ceiling tile to match; and painting interior surfaces of air ducts and heating cabinets with flat black paint to 1'-6" minimum depth. The contractor must coordinate with mechanical, plumbing, and electrical trades for above-ceiling work and verify appropriate access panels in non-accessible ceilings where service access may be required. The project is fully sprinklered and prepared by Apogee Consulting Group, P.A., for the U.S. Department of Veterans Affairs, Office of Construction and Facilities Management.
View the file
Other files
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
J
J
J
S SS SS SS S
S S
S S
SYMBOL DESCRIPTION
2' X 4' RECESSED FLAT LENS TROFFER
6" DIAMETER RECESSED DOWNLIGHT
4' LINEAR STRIP - SUSPENDED
CEILING MOUNTED LIGHT
PENDANT LIGHT
EXIT SIGN - WALL MOUNTED
EXIT SIGN - CEILING MOUNTED
SURFACE MOUNTED CURTAIN TRACK
RETURN GRILLE
SUPPLY DIFFUSER
EXHAUST GRILLE
SEMI-RECESSED SPRINKLER HEAD
CEILING MOUNTED LIFTS
ACCESS PANEL
CEILING MOUNTED FAN
PENDANT LIGHT
REFLECTED CEILING PLAN
LEGEND
ACT
GYP
CEILING TAGX'-X" AFF
DIRECT FINISH SYSTEM
LINEAR WOOD CEILING
CEILING CONTRACTOR TO MEASURE EACH CEILING
AREA AND ESTABLISH A CEILING LAYOUT TO BALANCE
BORDER WIDTHS AT OPPOSITE EDGES OF EACH ROOM.
AVOID USE OF LESS-THAN 6" TILES.
TRPONMLJGFEDCBA
H K
0.B 0.C 0.D 0.F
0.4
0.2
0.A 0.G 0.K
0.1
0.5
0.E
0.3
0.H
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM 111
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
RESIDENT
ROOM
107A
RESIDENT
TOILET
106A
RESIDENT
TOILET
105A
RESIDENT
TOILET
108A
RESIDENT
TOILET
109A
RESIDENT
TOILET
110A
RESIDENT
TOILET
111A
RESIDENT
TOILET
SOILED HOLD
LINEN
CLEAN
EQUIP
112A
RESIDENT
TOILET
113A
RESIDENT
TOILET
114A
RESIDENT
TOILET
SCREENED
PORCH
SUN ROOM
MECHANICAL
A-301
A-301 _____4
A-301
SEATING
SEATING
SEATING
LIVING ROOM
CORRIDOR
EXISTING GROUND FLOOR CEILILNG
0.J
NURSE
A.F.F.9' - 6"
A.F.F.9' - 6" A.F.F.9' - 6"
A.F.F.9' - 6"
A.F.F.10' - 6"
A.F.F.10' - 0"
A.F.F.10' - 6"
A.F.F.10' - 6"
A-303
A-305
A-304
A-304
A-303
A-304
A-304
A-104
A-104
A-513
A-513
A-513
A-513
A-513
A-513
S
1'-9" 1'-9" 1'-9" 1'-9" 1'-9" 1'-9"
1'-9" 1'-9" 1'-9" 1'-9"
2'-6"
1'-0"
/4
2'-1"2'-1"2'-1" 2'-1"2'-1"2'-1"2'-1" 2'-1" 2'-1"
1'-0" 1'-0"1
/2
/2
A.F.F.10' - 0"
1'-5"
1'-0"
1'-1"
9' - 6"
9' - 0"
A.F.F.10' - 0"
A.F.F.9' - 6"
5 5 5
5 5
A-306
_____ 2
A-306
A-301.1
A-301.1
A-301.1 _____4
A-301.1
2 551
A-305
A-304
1 1111 1 1 1
6 2'-0"
2'-0"
4"
4"
1'-0"
2"
1'-4"
1'-4"
1'-4"
1'-4"
A.F.F.9' - 6"
A5180 A5180 A5180 A5180 A5180 A5180 A5180 A5180 A5180A5180
SCOPE OF WORK LEGEND
NOT IN SCOPE
IN SCOPE
0.D
0.2
0.1
0.3
A-301
A-303
A1205M
QH-101
0.C
0.2
0.3
A.F.F.8' - 0"A.F.F.8' - 0"
A.F.F.9' - 0"
A.F.F.9' - 0"
RCP GENERAL NOTES
GENERAL
1. ALL CEILINGS ARE 9'-0" AFF (UNO).
2. ALL SOFFITS AND BULKHEADS ARE 8'-0" AFF (UNO).
3. CONTRACTOR IS TO REVIEW CEILING LAYOUT AND NOTIFY ARCHITECT OF ANY CONFLICTS
BEFORE PROCEEDING WITH CONSTRUCTION.
4. COORDINATE WITH MECHANICAL AND ELECTRICAL DRAWINGS FOR CEILING MOUNTED
DEVICES.
5. COORDINATE WITH MECHANICAL, PLUMBING, AND ELECTRICAL FOR ALL ABOVE CEILING
WORK TO MEET CEILING HEIGHTS.
6. REFER TO ROOM FINISH SCHEDULE FOR CEILING MATERIALS.
ALL WORK
1. LIGHTS, DIFFUSERS, EXIT SIGNAGE, SPRINKLER HEADS, AND SMOKE DETECTORS SHALL BE
CENTERED IN THE CEILING TILE.
2. EXIT SIGNAGE TO BE CENTERED OVER DOORS (UNO).
3. CENTER CEILING GRID IN BOTH DIRECTIONS OF THE SPACE (UNO).
4. ACCESS PANELS ARE NOT PERMITTED IN SOFFITS. CHECK ALL VALVES, FIRE DAMPERS,
REHEAT BOXES, ETC. FOR ACCESS POINTS. ARRANGE FIRE AND SMOKE DAMPERS FROM
NON-CORRIDOR SIDE.
5. THE CONTRACTOR SHALL VERIFY THAT ACCESS PANELS OF APPROPRIATE SIZE AND TYPE
ARE INSTALLED IN NON-ACCESSIBLE TYPE CEILINGS WHERE ACCESS, SERVICE, OR
ADJUSTMENT TO MECHANICAL, PLUMBING, ELECTRICAL ITEMS MAY BE REQUIRED.
6. PAINT CUT EDGES OF ACT TO MATCH CEILING TILE WHERE EXPOSED TO VIEW.
7. PAINT ALL INTERIOR SURFACES OF AIR DUCTS AND CONVECTOR / BASEBOARD HEATING
CABINETS THAT ARE VISIBLE THROUGH GRILLES AND LOUVERS WITH (1) ONE COAT OF FLAT
BLACK PAINT FOR 1'-6" MINIMUM OR BEYOND LINE OF SIGHT, WHICHEVER IS GREATER.
8. HANG SUSPENSION SYSTEM INDEPENDENTLY OF WALLS, COLUMNS, DUCTS, PIPES, AND
CONDUIT.
9. PROVIDE METAL BACKING AND/OR BRACING AS REQUIRED FOR LIGHT FIXTURES EXCEEDING
50LBS IN WEIGHT OR WEIGHING MORE THAN THE RATED LOAD CAPACITY OF THE OUTLET
BOX ON WHICH THE FIXTURE WILL BE MOUNTED. REFER TO NFPA 70 NATIONAL ELECTRICAL
CODE CHAPTER 3.
RENOVATION
1. REPAIR EXISTING CEILING GRID AND TILES AS NEEDED AT CONSTRUCTION TIE-INS.
2. WHERE NEW CEILINGS ARE INDICATED, REMOVE ALL EXISTING CEILINGS AND ACCESSORIES
TO ALLOW FOR PROPER INSTALLATION OF NEW CEILINGS. PATCH / REPAIR AS NEEDED.
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/8
/2
:5
:2
A M
C U s e rs
\e d ig g s \D o c u m e n ts
\A
-0
-V
A J a c k s o n -C o n s tr u c t
C L
C R e d ig g s D
X N
.r v t
A-104
GROUND FLOOR REFLECTED CEILING
PLAN
12 35JNL
CLC RESIDENTIAL
NEIGHBORHOOD
G.V. MONTGOMERY VAMC
1500 E. WOODROW WILSON AVENUE
JACKSON, MS 39216 JUNE 23, 2025
100% CONSTRUCTION DOCUMENTS
586-40123-060
7A
KC
N O
R T
H0 4 8 16
Scale: 1/8" = 1'-0"
GROUND FLOOR REFLECTED CEILING PLAN
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
Scale: 1/4" = 1'-0"
ENLARGED REFLECTED
CEILING PLAN 1
Scale: 1/4" = 1'-0"
ENLARGED REFLECTED
CEILING PLAN 2
N O
R T
H0 2 4 8
N O
R T
H0 2 4 8
1 PATIENT LIFT.
2 DIRECT FINISH SYSTEM EXTERIOR CEILING.
3 ROOF LEADER LOCATION.
4 ELECTRIC FIREPLACE CHASE.
5 P-2, ACCENT PAINT
6 2'X2' CEILING ACCESS HATCH; BASIS OF DESIGN:
ARMSTRONG WOODWORK GRILLE FORTE TORISON
SPRING ACCESS DOORS, CONTRACTOR TO VERIFY
LOCATIONS IN FIELD
A. ALL CEILINGS @ 9' - 0" AFF UNO.
B. ALL SOFFITS @ 8' - 0" AFF UNO.
C. CENTER DEVICES, DOWNLIGHTS, SPRINKLER
HEADS, HVAC GRILLS, ETC. IN CEILING TILES, UNO.
D. CENTER EXIT SIGNS OVER DOORS, UNO.
E. THE CONTACTOR SHALL VERIFY THAT ACCESS
PANELS OF APPROPRIATE SIZE AND TYPE ARE
INSTALLED IN GYPSUM BOARD CEILINGS WHERE
ACCESS, SERVICE, OR ADJUSTMENT TO
MECHANICAL, PLUMBING, OR ELECTRICAL ITEMS
MAY BE REQUIRED.
F. ACCESS PANELS ARE NOT PERMITTED IN SOFFITS
UNLESS SHOWN ON DRAWING.
G. REMOVE AND REPLACE CEILING GRID AND TILES.
1 Addendum 01 06/29/2026
Docusign Envelope ID: 3303808F-E285-81A0-83E8-46423FA2F6CE
7/8/2026
| Sheets |
| A-104 - GROUND FLOOR REFLECTED CEILING PLAN |
| 2026-07-08T19:09:13+0000 | |
| Digitally verifiable PDF exported from www.docusign.com |