Attachment 09 A-104 Cubicle Curtains.pdf

PDF 603 KB Posted

Attached to
Y1DA--586-401 | Construct CLC Residential Neighborhood | Jackson, MS | Scott Tom
Solicitation number
36C77626B0023
Issued by

About this file

This is a Reflected Ceiling Plan (RCP) for the Ground Floor of a construction project at the G.V. Montgomery Veterans Affairs Medical Center (VAMC) in Jackson, Mississippi. The drawing is part of 100% Construction Documents dated June 23, 2025, with Addendum 01 issued on June 29, 2026, for Project Number 23-060 (Building 586-401).

The scope of work includes removal and replacement of existing ceiling grid and tiles, with new ceilings specified at 9'-0" Above Finished Floor (AFF) and soffits/bulkheads at 8'-0" AFF throughout the facility. The plan details placement of multiple ceiling-mounted devices including 2'x4' recessed flat lens troffers, 6" diameter recessed downlights, 4' linear suspended strips, pendant lights, exit signs, supply diffusers, return grilles, exhaust grilles, semi-recessed sprinkler heads, ceiling-mounted lifts, ceiling-mounted fans, and access panels. Key requirements include centering all lights, diffusers, exit signage, sprinkler heads, and smoke detectors within ceiling tiles; centering exit signs over doors; balancing border widths at room edges; avoiding tiles less than 6" in width; painting exposed cut edges of acoustical ceiling tile to match; and painting interior surfaces of air ducts and heating cabinets with flat black paint to 1'-6" minimum depth. The contractor must coordinate with mechanical, plumbing, and electrical trades for above-ceiling work and verify appropriate access panels in non-accessible ceilings where service access may be required. The project is fully sprinklered and prepared by Apogee Consulting Group, P.A., for the U.S. Department of Veterans Affairs, Office of Construction and Facilities Management.

View the file

Other files

File Type Posted
36C77626B0023 0007.docx DOCX document
Attachment 01 C - FAR Clause 52.212-4 - Construction KAE.docx DOCX document
36C77626B0023 0006.docx DOCX document
Attachment 01 S05 - Tech Questions Tracker w clarifications v1.xlsx XLSX spreadsheet
36C77626B0023 0005.docx DOCX document
Attachment 02 23-060_Addendum 02 Door Tags Locations.pdf PDF
Attachment 01 Asbestos AHERA Baseline Survey--February 2017.pdf PDF
Attachment 01 S05 - Tech Questions Tracker.xlsx XLSX spreadsheet
36C77626B0023 0004.docx DOCX document
Attachment 05 117300 Ceiling Pt. Lift System.pdf PDF
Attachment 04 331000 Water Utilities.pdf PDF
Attachment 02 051200 StructSteelFraming.pdf PDF
Attachment 08 M-601.pdf PDF
Attachment 07 M-504.pdf PDF
Attachment 06 M-503.pdf PDF
Attachment 03 107315 Extruded Alum Canopy.pdf PDF
36C77626B0023 0003.docx DOCX document
GeoReport.VA CLC Neighborhood - Jackson MS.EB245012_locked_.pdf PDF
36C77626B0023 0002.docx DOCX document
S04 Site Visit Sign in Sheet 36C77626B0023.pdf PDF
36C77626B0023 0001.docx DOCX document
S02 36C77626B0023_1 Final.pdf PDF
Attachment 05 Wage Determination Hinds County MS 05_28_2026.pdf PDF
Attachment 04- Limitations on Subcontracting - Construction.pdf PDF
Attachment 3 P11 Vol2 Drawings SS Final.pdf PDF
Attachment 2 P11 Vol1 Drawings SS Final.pdf PDF
Attachment 06 - Site Visit Details.docx DOCX document
Attchment 1 23-060 Specs 100 percent SS 20250618 Final.pdf PDF
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

J

J

J

S SS SS SS S

S S

S S

SYMBOL DESCRIPTION

2' X 4' RECESSED FLAT LENS TROFFER

6" DIAMETER RECESSED DOWNLIGHT

4' LINEAR STRIP - SUSPENDED

CEILING MOUNTED LIGHT

PENDANT LIGHT

EXIT SIGN - WALL MOUNTED

EXIT SIGN - CEILING MOUNTED

SURFACE MOUNTED CURTAIN TRACK

RETURN GRILLE

SUPPLY DIFFUSER

EXHAUST GRILLE

SEMI-RECESSED SPRINKLER HEAD

CEILING MOUNTED LIFTS

ACCESS PANEL

CEILING MOUNTED FAN

PENDANT LIGHT

REFLECTED CEILING PLAN

LEGEND

ACT

GYP

CEILING TAGX'-X" AFF

DIRECT FINISH SYSTEM

LINEAR WOOD CEILING

CEILING CONTRACTOR TO MEASURE EACH CEILING

AREA AND ESTABLISH A CEILING LAYOUT TO BALANCE

BORDER WIDTHS AT OPPOSITE EDGES OF EACH ROOM.

AVOID USE OF LESS-THAN 6" TILES.

TRPONMLJGFEDCBA

H K

0.B 0.C 0.D 0.F

0.4

0.2

0.A 0.G 0.K

0.1

0.5

0.E

0.3

0.H

RESIDENT

ROOM

RESIDENT

ROOM

RESIDENT

ROOM 111

RESIDENT

ROOM

RESIDENT

ROOM

RESIDENT

ROOM

RESIDENT

ROOM

RESIDENT

ROOM

RESIDENT

ROOM

RESIDENT

ROOM

107A

RESIDENT

TOILET

106A

RESIDENT

TOILET

105A

RESIDENT

TOILET

108A

RESIDENT

TOILET

109A

RESIDENT

TOILET

110A

RESIDENT

TOILET

111A

RESIDENT

TOILET

SOILED HOLD

LINEN

CLEAN

EQUIP

112A

RESIDENT

TOILET

113A

RESIDENT

TOILET

114A

RESIDENT

TOILET

SCREENED

PORCH

SUN ROOM

MECHANICAL

A-301

A-301 _____4

A-301

SEATING

SEATING

SEATING

LIVING ROOM

CORRIDOR

EXISTING GROUND FLOOR CEILILNG

0.J

NURSE

A.F.F.9' - 6"

A.F.F.9' - 6" A.F.F.9' - 6"

A.F.F.9' - 6"

A.F.F.10' - 6"

A.F.F.10' - 0"

A.F.F.10' - 6"

A.F.F.10' - 6"

A-303

A-305

A-304

A-304

A-303

A-304

A-304

A-104

A-104

A-513

A-513

A-513

A-513

A-513

A-513

S

1'-9" 1'-9" 1'-9" 1'-9" 1'-9" 1'-9"

1'-9" 1'-9" 1'-9" 1'-9"

2'-6"

1'-0"

/4

2'-1"2'-1"2'-1" 2'-1"2'-1"2'-1"2'-1" 2'-1" 2'-1"

1'-0" 1'-0"1

/2

/2

A.F.F.10' - 0"

1'-5"

1'-0"

1'-1"

9' - 6"

9' - 0"

A.F.F.10' - 0"

A.F.F.9' - 6"

5 5 5

5 5

A-306

_____ 2

A-306

A-301.1

A-301.1

A-301.1 _____4

A-301.1

2 551

A-305

A-304

1 1111 1 1 1

6 2'-0"

2'-0"

4"

4"

1'-0"

2"

1'-4"

1'-4"

1'-4"

1'-4"

A.F.F.9' - 6"

A5180 A5180 A5180 A5180 A5180 A5180 A5180 A5180 A5180A5180

SCOPE OF WORK LEGEND

NOT IN SCOPE

IN SCOPE

0.D

0.2

0.1

0.3

A-301

A-303

A1205M

QH-101

0.C

0.2

0.3

A.F.F.8' - 0"A.F.F.8' - 0"

A.F.F.9' - 0"

A.F.F.9' - 0"

RCP GENERAL NOTES

GENERAL

1. ALL CEILINGS ARE 9'-0" AFF (UNO).

2. ALL SOFFITS AND BULKHEADS ARE 8'-0" AFF (UNO).

3. CONTRACTOR IS TO REVIEW CEILING LAYOUT AND NOTIFY ARCHITECT OF ANY CONFLICTS

BEFORE PROCEEDING WITH CONSTRUCTION.

4. COORDINATE WITH MECHANICAL AND ELECTRICAL DRAWINGS FOR CEILING MOUNTED

DEVICES.

5. COORDINATE WITH MECHANICAL, PLUMBING, AND ELECTRICAL FOR ALL ABOVE CEILING

WORK TO MEET CEILING HEIGHTS.

6. REFER TO ROOM FINISH SCHEDULE FOR CEILING MATERIALS.

ALL WORK

1. LIGHTS, DIFFUSERS, EXIT SIGNAGE, SPRINKLER HEADS, AND SMOKE DETECTORS SHALL BE

CENTERED IN THE CEILING TILE.

2. EXIT SIGNAGE TO BE CENTERED OVER DOORS (UNO).

3. CENTER CEILING GRID IN BOTH DIRECTIONS OF THE SPACE (UNO).

4. ACCESS PANELS ARE NOT PERMITTED IN SOFFITS. CHECK ALL VALVES, FIRE DAMPERS,

REHEAT BOXES, ETC. FOR ACCESS POINTS. ARRANGE FIRE AND SMOKE DAMPERS FROM

NON-CORRIDOR SIDE.

5. THE CONTRACTOR SHALL VERIFY THAT ACCESS PANELS OF APPROPRIATE SIZE AND TYPE

ARE INSTALLED IN NON-ACCESSIBLE TYPE CEILINGS WHERE ACCESS, SERVICE, OR

ADJUSTMENT TO MECHANICAL, PLUMBING, ELECTRICAL ITEMS MAY BE REQUIRED.

6. PAINT CUT EDGES OF ACT TO MATCH CEILING TILE WHERE EXPOSED TO VIEW.

7. PAINT ALL INTERIOR SURFACES OF AIR DUCTS AND CONVECTOR / BASEBOARD HEATING

CABINETS THAT ARE VISIBLE THROUGH GRILLES AND LOUVERS WITH (1) ONE COAT OF FLAT

BLACK PAINT FOR 1'-6" MINIMUM OR BEYOND LINE OF SIGHT, WHICHEVER IS GREATER.

8. HANG SUSPENSION SYSTEM INDEPENDENTLY OF WALLS, COLUMNS, DUCTS, PIPES, AND

CONDUIT.

9. PROVIDE METAL BACKING AND/OR BRACING AS REQUIRED FOR LIGHT FIXTURES EXCEEDING

50LBS IN WEIGHT OR WEIGHING MORE THAN THE RATED LOAD CAPACITY OF THE OUTLET

BOX ON WHICH THE FIXTURE WILL BE MOUNTED. REFER TO NFPA 70 NATIONAL ELECTRICAL

CODE CHAPTER 3.

RENOVATION

1. REPAIR EXISTING CEILING GRID AND TILES AS NEEDED AT CONSTRUCTION TIE-INS.

2. WHERE NEW CEILINGS ARE INDICATED, REMOVE ALL EXISTING CEILINGS AND ACCESSORIES

TO ALLOW FOR PROPER INSTALLATION OF NEW CEILINGS. PATCH / REPAIR AS NEEDED.

Engineers Architects

# KEY NOTES:

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

/8

/2

:5

:2

A M

C U s e rs

\e d ig g s \D o c u m e n ts

\A

-0

-V

A J a c k s o n -C o n s tr u c t

C L

C R e d ig g s D

X N

.r v t

A-104

GROUND FLOOR REFLECTED CEILING

PLAN

12 35JNL

CLC RESIDENTIAL

NEIGHBORHOOD

G.V. MONTGOMERY VAMC

1500 E. WOODROW WILSON AVENUE

JACKSON, MS 39216 JUNE 23, 2025

100% CONSTRUCTION DOCUMENTS

586-40123-060

7A

KC

N O

R T

H0 4 8 16

Scale: 1/8" = 1'-0"

GROUND FLOOR REFLECTED CEILING PLAN

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

Scale: 1/4" = 1'-0"

ENLARGED REFLECTED

CEILING PLAN 1

Scale: 1/4" = 1'-0"

ENLARGED REFLECTED

CEILING PLAN 2

N O

R T

H0 2 4 8

N O

R T

H0 2 4 8

1 PATIENT LIFT.

2 DIRECT FINISH SYSTEM EXTERIOR CEILING.

3 ROOF LEADER LOCATION.

4 ELECTRIC FIREPLACE CHASE.

5 P-2, ACCENT PAINT

6 2'X2' CEILING ACCESS HATCH; BASIS OF DESIGN:

ARMSTRONG WOODWORK GRILLE FORTE TORISON

SPRING ACCESS DOORS, CONTRACTOR TO VERIFY

LOCATIONS IN FIELD

A. ALL CEILINGS @ 9' - 0" AFF UNO.

B. ALL SOFFITS @ 8' - 0" AFF UNO.

C. CENTER DEVICES, DOWNLIGHTS, SPRINKLER

HEADS, HVAC GRILLS, ETC. IN CEILING TILES, UNO.

D. CENTER EXIT SIGNS OVER DOORS, UNO.

E. THE CONTACTOR SHALL VERIFY THAT ACCESS

PANELS OF APPROPRIATE SIZE AND TYPE ARE

INSTALLED IN GYPSUM BOARD CEILINGS WHERE

ACCESS, SERVICE, OR ADJUSTMENT TO

MECHANICAL, PLUMBING, OR ELECTRICAL ITEMS

MAY BE REQUIRED.

F. ACCESS PANELS ARE NOT PERMITTED IN SOFFITS

UNLESS SHOWN ON DRAWING.

G. REMOVE AND REPLACE CEILING GRID AND TILES.

1 Addendum 01 06/29/2026

Docusign Envelope ID: 3303808F-E285-81A0-83E8-46423FA2F6CE

7/8/2026

Sheets
A-104 - GROUND FLOOR REFLECTED CEILING PLAN
2026-07-08T19:09:13+0000
Digitally verifiable PDF exported from www.docusign.com

File details come from the government source that posted it. Updated .