Attachment_3_Equipment List.xlsx
XLSX spreadsheet 28 KB Posted
- Solicitation number
- N6449824R4028
About this file
This solicitation is for a competitive single award Firm Fixed Price Indefinite Delivery, Indefinite Quantity services contract for cooling water equipment and systems preventative maintenance/repair and cooling water analysis and chemical treatment services located at various Naval Surface Warfare Center Philadelphia Division government buildings at the Philadelphia Navy Yard. The services required include preventative maintenance and repair of cooling water pumps, motors, motor starters, cooling towers, automatic control valves, actuators, and other related equipment. The contractor must also provide cooling water analysis and chemical treatment services. A site visit will be held on February 20, 2024 at 9:30am EST, and requests to attend must be submitted by February 16, 2024 at 12:00pm EST. The opportunity is set aside for small businesses. The contracting agency is the Department of the Navy Naval Sea Systems Command.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment_0002_N6449824R4028.pdf | ||
| Amendment_0001_N6449824R4028.pdf | ||
| Attachment_7_PPQ.docx | DOCX document | |
| CDRL_A009_Asbestos_Containing_Material_Report.pdf | ||
| Attachment_5_Performance Requirements.docx | DOCX document | |
| CDRL_A007_Accident_Reports.pdf | ||
| Attachment_1_CoolingWater_PNBC_Site_Map.pdf | ||
| CDRL_A001_Contract Status Report.pdf | ||
| CDRL_A008_OSHA Citations and Violations CAR.pdf | ||
| Attachment_2_ELINS.xlsx | XLSX spreadsheet | |
| Attachment_6_PM_Checklists_1_thru_8.docx | DOCX document | |
| RFP N6449824R4028.pdf | ||
| CDRL_A005_Accident_Prevention_Plan.pdf | ||
| CDRL_A006_Activity_Hazard_Analysis.pdf | ||
| Attachment_6A_PM_Checklist_9.docx | DOCX document | |
| CDRL_A003_Contractors_Personnel_Roster.pdf | ||
| Attachment_4_Historical Repair Call.xlsx | XLSX spreadsheet | |
| CDRL_A002_Contractors_Maintenace_Program_Plan.pdf | ||
| CDRL_A004_Contractors_Quality_Management_Plan.pdf |
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1 PWS ATTACHMENT 3 OF COOLING WATER EQUIPMENT AND SYSTEM MAINTEANANCE AND REPAIR CONTRACT -- EQUIPMENT LIST 12/Sep/2023
| COOLING WATER PUMPS | ||||
| ID NO | DESC | MFR & MODEL NO. | LOCATION | CHECKLIST(S) |
| Pump 1A | CWR, 8350 GPM | Peerless, Model 24HH, Vertical Turbine Well Pump, S/N 9927108110-10-A | Bldg 77H, West Side | 1 |
| Pump 1B | CWR, 8350 GPM | Peerless, Model 24HH, Vertical Turbine Well Pump, S/N 9927108110-10-C | Bldg 77H, West Side | 1 |
| Pump 1C | CWR, 8350 GPM | Peerless, Model 24HH, Vertical Turbine Well Pump, S/N 9927108110-10-B | Bldg 77H, West Side | 1 |
| Pump 2A | CWR, 8350 GPM | Peerless, Model 18HH, Vertical Turbine Well Pump, S/N 9927108114-10-A | Bldg 77H, East Side | 1 |
| Pump 2B | CWR, 8350 GPM | Peerless, Model 18HH, Vertical Turbine Well Pump, S/N 9927108114-10-C | Bldg 77H, East Side | 1 |
| Pump 2C | CWR, 8350 GPM | Peerless, Model 18HH, Vertical Turbine Well Pump, S/N 9927108114-10-B | Bldg 77H, East Side | 1 |
| DTF | 3800 GPM | Peerless, Model 16HXB, Vertical Turbine Well Pump, S/N 9927108116-10-A | Bldg 77H, East Side | 1 |
| CTP-1 | CWR, 2020 GPM | Peerless, Model 8AD13.5, S/N 191854 | Bldg 87, Northeast | 1 |
| CTP-1A | CWR, 2020 GPM | Peerless, Model 8AD13.5, S/N 191915 | Bldg 87, Northeast | 1 |
| CTP-2 | CWS, 2020 GPM | Peerless, Model 8AD17, S/N 191853A | Bldg 87 Cooling Tower | 1 |
| CTP-2A | CWS, 2020 GPM | Peerless, Model 8AD17, S/N 191853B | Bldg 87 Cooling Tower | 1 |
| MOTORS, COOLING WATER PUMPS | ||||
| ID NO | DESC | MFR & MODEL NO. | LOCATION | CHECKLIST(S) |
| Pump 1A | 150 HP | US Motors, Frame 445TPA, Type RUI, S/N X 04 20152245-0001 R001 | Bldg 77H, West Side | 1 |
| Pump 1B | 150 HP | US Motors, Frame 445TPA, Type RUI, S/N X 04 20152245-0001 R002 | Bldg 77H, West Side | 1 |
| Pump 1C | 150 HP | US Motors, Frame 445TPA, Type RUI, S/N X 04 20152245-0001 R003 | Bldg 77H, West Side | 1 |
| Pump 2A | 250 HP | US Motors, Frame 445TPA, Type RUI, S/N X 04 20152246-0001 R003 | Bldg 77H, East Side | 1 |
| Pump 2B | 250 HP | US Motors, Frame 445TPA, Type RUI, S/N X 04 20152246-0001 R001 | Bldg 77H, East Side | 1 |
| Pump 2C | 250 HP | US Motors, Frame 445TPA, Type RUI, S/N X 04 20152246-0001 R002 | Bldg 77H, East Side | 1 |
| DTF Pump | 200 HP | US Motors, Frame 445TPA, Type RUI, S/N X 04 20152247-0001 R001 | Bldg 77H, East Side | 1 |
| CTP-1 | 40 HP | US Electric Motor, Type FR, Frame 364T, Model H658A | Bldg 87, Northeast | 1 |
| CTP-1A | 40 HP | US Electric Motor, Type FR, Frame 364T, Model H658A | Bldg 87, Northeast | 1 |
| CTP-2 | 150 HP | US Electric Motor, Type TCE, Frame 445TS | Bldg 87 Cooling Tower | 1 |
| CTP-2A | 150 HP | US Electric Motor, Type TCE, Frame 445TS | Bldg 87 Cooling Tower | 1 |
| MOTOR STARTERS, COOLING WATER PUMPS | ||||
| ID NO | DESC | MFR & MODEL NO. | LOCATION | CHECKLIST(S) |
| Pump 1A | VFD | ABB Model ACH550-BCR-180A-4+F267 S/N 2162803003 | Bldg 77H, West Side | 2 |
| Pump 1B | VFD | ABB Model ACH550-BCR-180A-4+F267 S/N 2162802884 | Bldg 77H, West Side | 2 |
| Pump 1C | VFD | ABB Model ACH550-BCR-180A-4+F267 S/N 2162802827 | Bldg 77H, West Side | 2 |
| Pump 2A | VFD | ABB Model ACH550-BCR-316A-4-F267 S/N 21622704375 | Bldg 77H, East Side | 2 |
| Pump 2B | VFD | ABB Model ACH550-BCR-316A-4-F267 S/N 2162703051 | Bldg 77H, East Side | 2 |
| Pump 2C | VFD | ABB Model ACH550-BCR-316A-4-F267 S/N 2162700589 | Bldg 77H, East Side | 2 |
| DTF Pump | Size 5 | Westinghouse, Cat # A200M5CX, 2045A41G03-Model J | Bldg 77H, East Side | 2 |
| CTP-1 | 40 HP | General Electric, Spectra 8000 MCC, Type FVNR | Bldg 87, Northeast | 2 |
| CTP-1A | 40 HP | General Electric, Spectra 8000 MCC, Type FVNR | Bldg 87, Northeast | 2 |
| CTP-2 | 150 HP | General Electric, Reduced Voltage, Model 331GM434J2AOD | Bldg 87 Cooling Tower | 2 |
| CTP-2A | 150 HP | General Electric, Reduced Voltage, Model 331GM434J2AOD | Bldg 87 Cooling Tower | 2 |
| CTP-3 | 7.5/55 HP | General Electric, Spectra 8000 MCC, Type 2S1WVT | Bldg 87, Northeast | 2 |
| CTP-4 | 7.5/55 HP | General Electric, Spectra 8000 MCC, Type 2S1WVT | Bldg 87, Northeast | 2 |
| CTP-5 | 7.5/55 HP | General Electric, Spectra 8000 MCC, Type 2S1WVT | Bldg 87, Northeast | 2 |
| MOTOR STARTERS, COOLING TOWER FAN MOTORS | ||||
| ID NO | DESC | MFR & MODEL NO. | LOCATION | CHECKLIST(S) |
| CT-1 (West Cell) | VFD | ABB Model ACH550-BCR-180A-4+F267 S/N 2162802780 | Pump House by 77H CT | 2 |
| CT-2 (Middle Cell) | VFD | ABB Model ACH550-BCR-180A-4+F267 S/N 2162802655 | Pump House by 77H CT | 2 |
| CT-3 (East Cell) | VFD | ABB Model ACH550-BCR-180A-4+F267 S/N 2162802938 | Pump House by 77H CT | 2 |
| CT-1 (N) | 50 HP, 2 Speed | General Electric, Spectra 8000 MCC, Type 2S1WVT | Bldg 87, Northeast | 2 |
| CT-1 (C) | 50 HP, 2 Speed | General Electric, Spectra 8000 MCC, Type 2S1WVT | Bldg 87, Northeast | 2 |
| CT-1 (S) | 50 HP, 2 Speed | General Electric, Spectra 8000 MCC, Type 2S1WVT | Bldg 87, Northeast | 2 |
| COOLING TOWER FAN MOTORS | ||||
| ID NO | DESC | MFR & MODEL NO. | LOCATION | CHECKLIST(S) |
| West Cell | 150 HP | TECO Westinghouse, Type AEHH-UW, Frame 445T, S/N VA E9158111002 | 77H Cooling Tower | 3 |
| Middle Cell | 150 HP | TECO Westinghouse, Type AEHH-UW, Frame 445T, S/N VA E9158109001 | 77H Cooling Tower | 3 |
| East Cell | 150 HP | TECO Westinghouse, Type AEHH-UW, Frame 445T, S/N NACC152106-1 | 77H Cooling Tower | 3 |
| North Cell | 50/12.5 HP | Marathon Electric, Type TFS, Frame 364T, 4VN364TTFS7229AP | 87 Cooling Tower | 3 |
| Middle Cell | 50/12.5 HP | Marathon Electric, Type TFS, Frame 364T, 4VN364TTFS7229AP | 87 Cooling Tower | 3 |
| South Cell | 50/12.5 HP | Marathon Electric, Type TFS, Frame 364T, 4VN364TTFS7229AP | 87 Cooling Tower | 3 |
| COOLING TOWERS | ||||
| ID NO | DESC | MFR & MODEL NO. | LOCATION | CHECKLIST(S) |
| CT-1 | 25,000 GPM | Composite Cooling Solutions, Model 3FT4248-150-P6-48-FM | 77H Cooling Tower | 3 |
| 1 Fan per Cell Tuf-lite V5.9 Axial Flow Fan, Diameter 28 feet, 8 blades,134.6 GPM | ||||
| Reducer Amarillo Model 1311 Right Angle Double Reduction | ||||
| CT-1 | 4035 GPM | Marley, Model NC7233GS, S/N 119752-NC7233GS-98 | 87 Cooling Tower | 3 |
| 3 Cell, Fan Size 120H3-9, Gear Reducer Type 22.3, | ||||
| Electric Basin Heaters, 2 per Cell, 12 KW each | ||||
| Tower Piping Heat Trace, Thermon Type FLX, Thermon Thermostat | ||||
| Cat # E4X-1-SR |
| AUTOMATIC CONTROL VALVES, ACTUATORS | ||||
| ID NO | DESC | MFR & MODEL NO. | LOCATION | CHECKLIST(S) |
| FCV-111 | 20 Inch Butterfly Valve | Bray, Model SSL2-C200-170 92-255-XP24D-SW7H-5 | 77H Cooling Tower | 4 |
| FCV-112 | 20 Inch Butterfly Valve | Bray, Model SSL2-C200-170 92-255-XP24D-SW7H-5 | 77H Cooling Tower | 4 |
| FCV-113 | 20 Inch Butterfly Valve | Bray, Model SSL2-C200-170 92-255-XP24D-SW7H-5 | 77H Cooling Tower | 4 |
| FCV-114 | 36 Inch Butterfly Valve | Bray, Model F800-060/70800-67, S/N 81731N01-1 98F1ILO-213A11G000S0 | 77H Cooling Tower | 4 |
| LV 120-1 | 24 Inch Butterfly Valve-Basin Level Control-North | Bray, Model SSF2-C240-170 73E2-14SR4JS-EP5XH-10EXT, S/N 160217 | 77H Cooling Tower | 4 |
| LV 120-2 | 24 Inch Butterfly Valve-Basin Level Control-Middle | Bray, Model SSF2-C240-170 73E2-14SR4JS-EP5XH-10EXT, S/N 160225 | 77H Cooling Tower | 4 |
| LV 120-3 | 24 Inch Butterfly Valve-Basin Level Control-South | Bray, Model SSF2-C240-170 73E2-14SR4JS-EP5XH-10EXT, S/N 160223 | 77H Cooling Tower | 4 |
| DDG51 | 30 Inch Butterfly Valve | Keystone Valve, Dual Cylinder, Air Operated, SM0061, Fig. #105 | 77H LBES Test Site | 4 |
| IPS | 30 Inch Butterfly Valve | Keystone Valve, Dual Cylinder, Air Operated, SM0061, Fig. #105 | 77H LBES Test Site | 4 |
| BPV-2 | 36 Inch Butterfly Valve | Keystone Valve, Dual Cylinder, Air Operated, SM0061, Fig. #105 | 77H LBES Test Site | 4 |
| SOV | 36 Inch Butterfly Valve | Keystone Valve, Dual Cylinder, Air Operated, SM0061, Fig. #105 | Bldg 77H, East Side | 4 |
| LV-110 Make-up | 4 Inch Cage Valve | Bray, Model SSL2-C040-170 93-1193-EPFXH-FR-5, S/N S01005603/1 Valve S/N S060000060401 | Pump House | 4 |
| Hd Tank Htg | 1 inch steam valve | Dodge Engineering, ES62B2 | 77H, East Side | 4 |
| V5 | 14 inch Butterfly Valve | Keystone Pneumatic Actuator, Model # F79U-066U | 77H, East Side | 4 |
| V6 | 14 inch Butterfly Valve | Keystone Pneumatic Actuator, Model # F79U-066U | 77H, East Side | 4 |
| V1 | 12 Inch Butterfly Valve | Dodge Engineering, RE25TG1 | Bldg 87, Northeast | 4 |
| V2 | 2.5 Inch Butterfly Valve | Belimo, GM24-SR (Dual), w/Feedback Pot | Bldg 87, South Center | 4 |
| V3 | 14 Inch Butterfly Valve | Dodge Engineering, RE25TB2 H&S | Bldg 87 Cooling Tower | 4 |
| V4 | 14 Inch Butterfly Valve | Dodge Engineering, RE25TB2 H&S | Bldg 87 Cooling Tower | 4 |
| V5 | 4 Inch Butterfly Valve | Belimo, AF24-SR-AL (Dual) | Bldg 87, NE, Tank WTS | 4 |
| V6 | 10 Inch Butterfly Valve | Dodge Engineering, RE30A2 | Bldg 87, AMR | 4 |
| Chiller | 4 Inch Butterfly Valve | Dodge Engineering RE6A2 | Bldg 87, Chiller Rm | 4 |
| V7 | 6 Inch Butterfly Valve | Dodge Engineering, KS2-6-S1 | Bldg 87, AMR, WTS-2 | 4 |
| V8 | 8 Inch Butterfly Valve | Dodge Engineering, KS2-8-S1 | Bldg 87, AMR, WTS-2 | 4 |
| V9 | 10 Inch Butterfly Valve | Dodge Engineering, PS-1200 | Bldg 87, Tank WTS-1 | 4 |
| V10 | 8 Inch Butterfly Valve | Dodge Engineering, PS-850 | Bldg 87, Tank WTS-1 | 4 |
| BALANCING VALVES | ||||
| ID NO | DESC | MFR & MODEL NO. | LOCATION | CHECKLIST(S) |
| BLV-8 | 10" butterfly balancing valve for CT-1 Cell 1 Pump Suction | IMI Flow Design Model VF1000 | CT-1 Cell 1 Pump Suction | 4 |
| BLV-9 | 10" butterfly balancing valve for CT-1 Cell 2 Pump Suction | IMI Flow Design Model VF1000 | CT-1 Cell 2 Pump Suction | 4 |
| BLV-10 | 10" butterfly balancing valve for CT-1 Cell 3Pump Suction | IMI Flow Design Model VF1000 | CT-1 Cell 3Pump Suction | 4 |
| BLV-11 | 10" butterfly balancing valve for CT-1 Cell 4 Pump Suction | IMI Flow Design Model VF1000 | CT-1 Cell 4 Pump Suction | 4 |
| BLV-12 | 16" butterfly balancing valve for CWP-1 Pump Discharge | IMI Flow Design Model VF1600 | CWP-1 Pump Discharge | 4 |
| BLV-13 | 16" butterfly balancing valve for CWP-2 Pump Discharge | IMI Flow Design Model VF1600 | CWP-2 Pump Discharge | 4 |
| BLV-14 | 16" butterfly balancing valve for CWP-3 Pump Discharge | IMI Flow Design Model VF1600 | CWP-3 Pump Discharge | 4 |
| AUTOMATIC CONTROL VALVES | ||||
| ID NO | DESC | MFR & MODEL NO. | LOCATION | CHECKLIST(S) |
| Head Tank | 14 Inch Cla-Valve | CLA-VAL, Catalog # 210-81/610-81, Altitude and Back Pressure | Bldg 77H East Side | 8 |
| 6 Inch Cla-Valve | CLA-VAL, 50-01-7937A Size 6 50-01BPV E999996 DBBBB150A | Bldg 670 East Side | 8 |
| DDC CONTROL SYSTEM SENSORS | ||||
| ID NO | DESC | MFR & MODEL NO. | LOCATION | CHECKLIST(S) |
| LT-110A | Cooling Tower Basin Level Transmitter A | Rosemont 5302HA1S1V4AE00306DAE5Q4+751AM4E5BBT | 77H Cooling Tower | 5 |
| TT-105A | Cooling Tower Basin Temperature Transmitter A | Rosemont 3144D1A2E5M5G1C4Q4U6XA+0183N22E2C60A480F58E5XA | 77H Cooling Tower | 5 |
| TT-105B | Cooling Tower Basin Temperature Transmitter B | Rosemont 3144D1A2E5M5G1C4Q4U6XA+0183N22E2C60A480F58E5XA | 77H Cooling Tower | 5 |
| PT-1 | DDG51 Site Pressure | Pressure Transducer, Veris Model PH-100 | DDG51 LBES | 5 |
| PT-2 | IPS Site Pressure | Pressure Transducer, Veris Model PH-100 | IPS LBES | 5 |
| LT-110B | Cooling Tower Basin Level Transmitter B | Rosemont 5302HA1S1V4AE00306DAE5Q4+751AM4E5BBT | 77H Cooling Tower | 5 |
| HT-T | 77H Head Tank Temp. | 1k Immersion Sensor, Bapi Model ALC/T1K(30-234)-1-4 | 77H Head Tank | 5 |
| OA | Outside Air Sensor | 10k Therm., Bapi Model ALC/10K-2-O | Pump House | 5 |
| CWR Temp | Clg. Wtr. Return Temp. | 1k Immersion Sensor, Bapi Model ALC/T1K(30-234)-1-4 | 77H Trench | 5 |
| Hd Tk Htg | Head Tank Supply Tem | 1k Immersion Sensor, Bapi Model ALC/T1K(30-234)-1-4 | 77H | 5 |
| LS-1 | Level Sensor, Tank 1 | Radar Level Gauge, Apex Model APEXBC1D1SC2NO4A101C1E5M1 | 77H, Pump Set 1 | 5 |
| LS-1 | Level Sensor, Tank 1 | Rosemont Radar Level Transmitter, Model 5402AH1E52SPVAAM1C1 | 77H, Pump Set 1 | 5 |
| LS-2 | Level Sensor, Tank 2 | Radar Level Gauge, Apex Model APEXBC1D1SC2NO4A101C1E5M1 | 77H, Pump Set 2 | 5 |
| LS-2 | Level Sensor, Tank 2 | Rosemont Radar Level Transmitter, Model 5402AH1E52SPVAAM1C1 | 77H, Pump Set 2 | 5 |
| TI-105B-1 | Cooling Tower Basin Temperature Indicator | Ashcroft 50EI60E480-20/120XYW | 77H Cooling Tower Basin | 5 |
| FT-1 | Flow Transmitter, CWR | J-TEC, Model No. VL600 TRI | 87 Cooling Tower | 5 |
| FT-2 | Flow Transmitter, CWS | J-TEC, Model No. VL600 TRI | 87 Cooling Tower | 5 |
| TS-1 | Temperature Sensor | ACI, Model ACI/3000-I-8 | Bldg 87, NE, CWR | 5 |
| TS-2 | Temperature Sensor | ACI, Model ACI/3000-I-8 | Bldg 87, Above WTS-1 | 5 |
| 0AS-1 | Outdoor Air Sensor | Vaisala, Model HMD60Y0 | Outside Bldg 87, NE | 5 |
| PT-1 | Pressure Transmitter | Setra, Model No. C280E (0-100 PSI) | Bldg 87, South, Center | 5 |
| LT-1 | Level Transmitter | Omega, Model No. LV5200/LV5900 | Bldg 87 Cooling Tower | 5 |
| LT-3 | Level Transmitter | Omega, Model No. LV5200/LV5900 | Bldg 87 Cooling Tower | 5 |
| LT-4 | Level Transmitter | Setra, Model no. C207 (0-25 PSI) | Bldg 87, Tank WTS-1 | 5 |
| LWC | Low Level Switch | GEMS, Model No. ULS-11 | Bldg 87, Tank WTS-1 | 5 |
| LS-1 | Low Level Switch | GEMS, Model No. LS-700-316SS | Bldg 87 Cooling Tower | 5 |
| LS-3 | Low Level Switch | GEMS, Model No. LS-700-316SS | Bldg 87 Cooling Tower | 5 |
| LS-2 (AMR) | Low Level Switches | GEMS, Model No. LS-800-316SS | Bldg 87, AMR, WTS-2 | 5 |
| LS-3 (AMR) | Low Level Switches | GEMS, Model No. LS-800-316SS | Bldg 87, AMR, WTS-3 | 5 |
| LWC | Low Level Switch | GEMS, Model No. ULS-11 | Bldg 87, AMR, WTS-3 | 5 |
| FS-1 | Flow Switch | Kele, Model No. F61MB-1 | Bldg 87, AMR, WTS-4 | 5 |
| DDC CONTROL SYSTEM | ||||
| ID NO | DESC | MFR & MODEL NO. | LOCATION | CHECKLIST(S) |
| DDC | Control System | Automated Logic Corporation; includes Automated Logic PLCs | Bldg 87, NE and AMR | 7 |
| DDC | Control System | PCS system; includes Allen Bradley PLCs | Bldg 77H, IT Room | 7 |
| Control Cabinet | PCS-RI001 PCS-HMI01 | Bldg 77H Pumpset 1 | 7 | |
| Control Cabinet | PCS-CP01 | Bldg 77H Pumpset 2 | 7 | |
| Control Cabinet | PCS-RI002 | Cooling Tower Control House | 7 |
| BILGE PUMPS | ||||
| ID NO | DESC | MFR & MODEL NO. | LOCATION | CHECKLIST(S) |
| PUMP #1 | BILGE PUMP | VERTIFLO 800 | BLDG. 633 | 9 |
| PUMP #2 | BILGE PUMP | VERTIFLO 800 | BLDG. 633 | 9 |
| PUMP #3 | BILGE PUMP | VERTIFLO 800 | BLDG. 633 | 9 |
| PUMP #4 | BILGE PUMP | VERTIFLO 800 | BLDG. 633 | 9 |
| PUMP #6 | BILGE PUMP | VERTIFLO 800 | BLDG. 633 | 9 |
| PUMP #7 | BILGE PUMP | VERTIFLO 800 | BLDG. 633 | 9 |
| PUMP #8 | BILGE PUMP | VERTIFLO 800 | BLDG. 633 | 9 |
| PUMP #10 | BILGE PUMP | VERTIFLO 814 | BLDG. 633 | 9 |
| HEAD TANK FREEZE PROTECTION CIRCULATION PUMP | ||||
| ID NO | DESC | MFR & MODEL NO. | LOCATION | CHECKLIST(S) |
| PUMP B | HEAD TANK FREEZE PROTECTION CIRCULATION PUMP | BALDOR M3218T/ 5 H.P. 208-230/460/3/60 | BLDG. 77H | 9 |
&"Times New Roman,Regular"&10&Z&F &"Times New Roman,Regular"Page &P of &N
File details come from the government source that posted it. Updated .