ATTACHMENT 18 - Telecom 3 of 6.pdf

PDF 18 MB Posted

Attached to
Y1AZ--EHRM Infrastructure Upgrades Construction West Palm Beach Federal contract opportunity
Solicitation number
36C77623B0045
Issued by
Department of Veterans Affairs Technology Acquisition Center Austin

About this file

This attachment is related to solicitation number 36C77623B0045 from the Department of Veterans Affairs Technology Acquisition Center Austin for infrastructure upgrades at the West Palm Beach facility. The solicitation seeks a contractor to provide construction services for upgrades to the enterprise human resources management system infrastructure, including replacing servers, storage, and network equipment. Proposals are due by April 15, 2023, with the contract to be awarded by June 1, 2023. The period of performance is one year from the award date. The solicitation is unrestricted and open to small and large businesses.

View the file

Other files for this federal contract opportunity

Other files attached to Y1AZ--EHRM Infrastructure Upgrades Construction West Palm Beach, newest first.
File Type Posted
Cart Lift Motor Photos.pdf PDF
Updated Drawings for Clarifications.pdf PDF
36C77623B0045 0003.pdf PDF
Clarifications to Technical Questions 9-5-23.pdf PDF
Map of Wells Question 66.pdf PDF
Technical Questions - FINAL - West Palm Beach 8-21-23.pdf PDF
36C77623B0045 0002.pdf PDF
Photos for Responses to Questions 124 and 127.pdf PDF
Site Visit Sign-in Sheet - West Palm Beach 7-19-23.pdf PDF
36C77623B0045 0001.pdf PDF
ATTACHMENT 24 - Construction Wage Rates - Palm Beach 7-7-23.pdf PDF
ATTACHMENT 7 - Civil 4 of 5.pdf PDF
ATTACHMENT 10 - Fire Protection.pdf PDF
ATTACHMENT 22 - Contractor Core Work Hours.pdf PDF
ATTACHMENT 26 - Site Visit Instructions.pdf PDF
36C77623B0045 - 7-6-23.pdf PDF
ATTACHMENT 6 - Civil 3 of 5.pdf PDF
ATTACHMENT 11 - Mechanical 1 of 2.pdf PDF
ATTACHMENT 14 - Security.pdf PDF
ATTACHMENT 15 - Structural.pdf PDF
ATTACHMENT 17 - Telecom 2 of 6.pdf PDF
ATTACHMENT 21 - Telecom 6 of 6.pdf PDF
ATTACHMENT 25 - Contractor Safety - Environmental Form.docx DOCX document
ATTACHMENT 4 - Civil 1 of 5.pdf PDF
ATTACHMENT 5 - Civil 2 of 5.pdf PDF
ATTACHMENT 16 - Telecom 1 of 6.pdf PDF
ATTACHMENT 19 - Telecom 4 of 6.pdf PDF
ATTACHMENT 23 - Limitations on Subcontracting - Construction.docx DOCX document
ATTACHMENT 24 - Construction Wage Rates - Palm Beach 3-24-23.pdf PDF
ATTACHMENT 1 - Specifications.pdf PDF
ATTACHMENT 2 - General.pdf PDF
ATTACHMENT 8 - Civil 5 of 5.pdf PDF
ATTACHMENT 9 - Electrical.pdf PDF
ATTACHMENT 12 - Mechanical 2 of 2.pdf PDF
ATTACHMENT 13 - Plumbing.pdf PDF
ATTACHMENT 20 - Telecom 5 of 6.pdf PDF
ATTACHMENT 3 - Architectural.pdf PDF
Show all 37

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

JJ

HH

G8G8

GG

FF

EE

DD

C8C8

CC

BB

A8A8

8 9

9 9.2

9.2 9.8

9.8 10.4

10.4

11.2

11.2 11.8

11.8

12.2

12.2

1818.2

18.2

19.6

19.6

19.8

19.8

20.8

20.821.2

21.2 22

A6A6

AA

H4H4

B01-TN326

B01-TN327

TR 1-9A-225

TR 1-9B-227

AREA A

AREA B

AREA C

AREA D

ROUTE CABLING TO

TELECOM ROOM

TR 1-9A-225

ROUTE CABLING TO

TELECOM ROOM

TR 1-9B-227

1 2

18"x4" 18"x4"

"x

18"x4"

"x

"x

4"

"x

4"

18"x4"

18"x4"

"x

18"x4"

18"x4"

18"x4"

(4) SS44 (4) SS44

18"x4"18"x4"

(4) SS44

(4) SS44

(4) SS44

(4) SS44

LEGEND

DELINIATATION LINE BETWEEN

TELECOM ROOMS. ROUTE THE CABLING

FOR ALL SYSTEMS TO THE TELECOM

ROOMS SHOWN ON THE DRAWINGS

BASED ON THIS SEPARATION LINE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

6 South Old Orchard Ave, Saint Louis, MO 63119 T: 800.404.7677 www.introba.com

B

IM

/2

V

A W e s t P a lm

B e a c h

E H

R M

I n fr a s tr u c tu re U p g ra d e s D e s ig n /5

-7

.B

.T

R

.r v t

/2

/2

:1

:5

A

M

B01-TN190

NINTH LEVEL OVERALL PLAN -

TELECOM

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

INFRASTRUCTURE UPGRADES

WEST PALM BEACH, FL

548-22-700

03/31/23 PR TL

B01

1" = 20'-0"1

NINTH LEVEL OVERALL PLAN - TELECOM

PLAN NORTH

20 20 40

1" = 20'-0"

FEETSCALE

KEYED NOTES:#

1. PROVIDE (2) 4" CONDUITS FROM TR 1-8A-222 TO TR

1-9A-225 FOR B-SIDE VERTICAL BACKBONE CABLING.

2. PROVIDE (2) 4" CONDUITS FROM TR 1-8B-245 TO TR

1-9B-227 FOR A-SIDE VERTICAL BACKBONE CABLING.

GENERAL NOTES:

1. CONTRACTOR SHALL COORDINATE THE EQUIPMENT'S

INSTALLATION AND FINAL LOCATION WITH THE ELECTRICAL

AND MECHANICAL DIVISION. REFER TO ELECTRICAL,

MECHANICAL AND PLUMBING DRAWINGS.

2. CONTRACTOR SHALL INSTALL PATHWAY DIVIDERS, RADIUS

DROP, AND ANY OTHER FITTING FOR A PROPER CABLE

RUNWAY INSTALLATION.

3. CONTRACTOR SHALL COORDINATE THE HILTI SPEED

SLEEVE LOCATIONS WITH THE PATHWAY SYSTEM LAYOUT

OUTSIDE EACH TELECOM ROOM. REFER TO FLOOR PLAN

DRAWINGS.

4. CONTRACTOR SHALL INSTALL BACKBONE RISER SLEEVES

AND CONDUITS OF THE SIZE AS INDICATED ON THE PLANS.

REFER TO SECTION 27 10 00 STRUCTURED CABLING AND

SECTION 27 05 33 CONDUITS AND BOXES FOR

COMMUNICATIONS SYSTEMS.

5. CONTRACTOR SHALL X-RAY CONCRETE FLOOR BEFORE

CORE DRILLING. CONTRACTOR SHALL COORDINATE WITH

THE COR BEFORE BEGINNING DRILLING.

6. CONTRACTOR SHALL FIRESTOP RISER SLEEVES AND EMPTY

SPARE RISER SLEEVES. REFER TO SECTION 07 84 00

FIRESTOPPING.

7. GOVERNMENT EQUIPMENT WILL BE RELOCATED BY

GOVERNMENT IT PERSONNEL. CONTRACTOR WILL HAVE

TECHNICIANS AVAILABLE TO PROVIDE SUPPORT DURING

OUTAGES AND CUT-OVERS. COORDINATE WORK WITH

THE COR.

8. CONTRACTOR SHALL PROVIDE MTP, FIBER OPTIC TRUNK

CABLES FOR SIDE A AND SIDE B BACKBONE FROM THE

DATA CENTER TO EACH TELECOMMUNICATIONS ROOM.

COORDINATE WITH COR.

9. CONTRACTOR SHALL PROVIDE FIBER OPTIC PATCH

CABLES FOR SIDE A AND SIDE B FROM THE FIBER OPTIC

DISTRIBUTOR TO EQUIPMENT CABINETS. COORDINATE

WITH COR.

10. CONTRACTOR SHALL VERIFY FIBER OPTIC CABLES

MEASUREMENTS PRIOR TO ORDERING. COORDINATE WITH

COR.

11. PATHWAY SHOWN IN HALFTONE IS EXISTING AND SHALL

REMAIN IN PLACE. ROUTE NEW FIBER OPTIC BACKBONE

CABLING THROUGH EXISTING INFRASTRUCTURE AS

NOTED.

Revisions: Date:

G8G8

GG

FF

EE

DD

C8C8

8 9

9 9.2

9.2 9.8

9.82

H4H4

GW

GW

GW

EX

CAM

CAM

CAM

CAM

GWGW

5 5

1 1

1 1

1 1

1 1

1 1

1 1 1

1 1

EXAM

9A-320

EXAM

9A-322

EXAM

9A-324

EXAM

9A-328

OFFICE

9A-326

EXAM

9A-330

EXAM

9A-332

EXAM

9A-334

OFFICE

9A-336

OFFICE

9A-338

EXAM

9A-340

EXAM

9A-342

EXAM

9A-344

EXAM

9A-346

OFFICE

9A-348

OFFICE

9A-350

EXAM

9A-352

EXAM

9A-354

STAFF LOCKERS

9A-356

STAFF TOILET

9A-356A

STAFF LOUNGE / BREAK

9A-356B

STAIR #4

STAIR

STORAGE / SUPPLY

9A-312

PACT SOCIAL WORKER

9A-314

SUPPLY

9A-316

EMS

9A-318

MECHANICAL

9A-304A

EXAM

9A-113

EXAM

9A-115

EXAM

9A-117

OFFICE

9A-119

OFFICE

9A-121

EXAM

9A-123

EXAM

9A-125

EXAM

9A-127

EXAM

9A-129

OFFICE

9A-131

OFFICE

9A-133

EXAM

9A-135

EXAM

9A-137

EXAM

9A-139

EXAM

9A-141

OFFICE

9A-143

OFFICE

9A-145

EXAM

9A-147

EXAM

9A-149

ASSOC. CHIEF

9A-151

OFFICE

9A-153

CHIEF PRIMARY CARE

9A-155

ADMIN. OFFICE

9A-165

OFFICE

9A-163

OFFICE

9A-161

CORRIDOR

9A-C1C

CORRIDOR

9A-C1D

CORRIDOR

9A-C1E

CORRIDOR

9A-C1F

CORR.

9A-C1

ALCOVE

9A-234

WAITING

9A-202

CORRIDOR

9A-C7

ROOM

9A-C7A

ROOM

9A-C7B

ROOM

9A-C7C

PATIENT TOILET

9A-203

TELCOM.

9A-204

EQUIP. ALCOVE

9A-205

PATIENT TOILET

9A-206

DIETICIAN

9A-207

OFFICE

9A-208

NUTRITIONIST

9A-209

OFFICE

9A-211

ALCOVE

9A-212

OFFICE

9A-213

OFFICE

9A-214

OFFICE

9A-215

OFFICE

9A-216

OFFICE

9A-217

STAFF TOILET

9A-218

VITALS

9A-219

EKG

9A-220

MEDICATION

9A-221

WOMEN TOILET

9A-222

MEN TOILET

9A-223

SUPPLIES

9A-224

TR

9A-225

SOILED TOILET

9A-226

ELECT.

9A-227

OFFICE

9A-228

OFFICE

9A-229

OFFICE

9A-231EXAM

9A-233

PATIENT TOILET

9A-220A

PATIENT TOILET

9A-220B

RECEPTION

9A-210

CLOSET

9A-208A

CLOSET

9A-211A

CORR.

9A-C2

UNISEX TOILET

9B-200

STAIR #5

STAIR

EXISTING SOILED SERVICE LOBBY

9B-302

EXISTING SOILED LINEN CHUTE

9B-302A

ELECTRICAL

9B-302B

TEL.

9B-302C

ELEV.

S-5

ELEV.

S-4

B01-TN326

KEY PLAN

AREA A

PLAN NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

6 South Old Orchard Ave, Saint Louis, MO 63119 T: 800.404.7677 www.introba.com

B

IM

/2

V

A W e s t P a lm

B e a c h

E H

R M

I n fr a s tr u c tu re U p g ra d e s D e s ig n /5

-7

.B

.T

R

.r v t

/2

/2

:2

:0

A

M

B01-TN190A

NINTH LEVEL FLOOR PLAN - AREA

A - TELECOM

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

INFRASTRUCTURE UPGRADES

WEST PALM BEACH, FL

548-22-700

03/31/23 PR TL

B01

1/8" = 1'-0"1

NINTH LEVEL FLOOR PLAN - AREA A - TELECOM

1. EXISTING TELECOMMUNICATIONS ROOM.

2. EXISTING CONDITIONS WERE NOT OBSERVED ON SITE

VISITS, REFER TO AS BUILTS FOR DATA DEVICE LAYOUTS.

3. DATA OUTLET RELOCATED FROM DEMOLISHED WALL IN

NEW TR.

KEYED NOTES:#

1. REFER TO SHEET T-000 FOR GENERAL NOTES AND LEGENDS.

2. CONTRACTOR SHALL INSTALL BACKBONE RISER SLEEVES AND

CONDUITS OF THE SIZE AS INDICATED ON THE PLANS. REFER

TO SECTION 27 10 00 STRUCTURED CABLING AND SECTION 27

05 33 CONDUITS AND BOXES FOR COMMUNICATIONS

SYSTEMS.

3. CONTRACTOR SHALL X-RAY CONCRETE FLOOR BEFORE CORE

DRILLING. CONTRACTOR SHALL COORDINATE WITH THE COR

BEFORE BEGINNING DRILLING.

4. CONTRACTOR SHALL FIRESTOP RISER SLEEVES AND EMPTY

SPARE RISER SLEEVES. REFER TO SECTION 07 84 00

FIRESTOPPING.

5. CONTRACTOR SHALL INSTALL AN VERTICAL LADDER TYPE

CABLE TRAY ON THE WALL ABOVE THE VERTICAL RISER

SLEEVES FOR BACKBONE CABLE SUPPORT AS INDICATED ON

THE PLANS. THE CABLE TRAY SHALL BE SECURELY

ANCHORED TO THE WALL SUFFICIENT TO SUPPORT THE

TOTAL WEIGHT OF CABLES AND CABLE TRAY PLUS 50%.

6. CONTRACTOR SHALL INSTALL CABLE SUPPORTS SUFFICIENT

TO SUPPORT COMMUNICATIONS CABLES ON THE VERTICAL

CABLE TRAY WITHOUT DAMAGING OR DEFORMING THE CABLE.

7. CONTRACTOR SHALL INSTALL NEW J-HOOKS WHERE THERE IS

NO CABLE TRAY OR COMMUNICATIONS CONDUIT UNLESS

OTHERWISE NOTED.

8. CONTRACTOR SHALL INSTALL NEW CATEGORY 6A PATCH

PANELS IN THE TELECOMMUNICATION ROOM AS INDICATED ON

RACK ELEVATIONS.

9. CONTRACTOR SHALL RE-TERMINATE AND TEST CABLING

REMOVED FROM ANY WALL MOUNT EQUIPMENT UNLESS

OTHERWISE NOTED. TESTING SHALL BE PERFORMED BY THE

CONTRACTOR DURING COMMISSIONING.

10. CONTRACTOR SHALL INSTALL NEW CATEGORY 6A

TELECOMMUNICATIONS/DATA OUTLET AS INDICATED.

EXISTING COMMUNICATION OUTLET BOXES AND CONDUITS TO

BE REUSED.

11. CONTRACTOR SHALL REPLACE ALL DATA CABLE WITH NEW

CATEGORY 6A CABLE UNLESS OTHERWISE NOTED.

12. CONTRACTOR SHALL TERMINATE COMMUNICATIONS CABLES

WITH NEW CATEGORY MODULAR JACKS TO MATCH THE

COMMUNICATION CABLE PERFORMANCE SPECIFICATIONS.

NEW MODULAR JACKS SHALL BE OF THE SAME

MANUFACTURER AS THE FACE PLATES, PATCH PANELS, AND

PATCH CABLES.

13. CONTRACTOR SHALL INSTALL NEW CATEGORY 6A CABLES

AND CONNECTIVITY COMPONENTS THAT ARE OF THE SAME

MANUFACTURER, INCLUDING CABLE, MODULAR JACKS, PATCH

PANELS, FACEPLATES, AND PATCH CABLES.

14. CONTRACTOR SHALL TEST ALL NEW AND EXISTING RE-

TERMINATED CABLES IN ACCORDANCE WITH THE

SPECIFICATION 27 05 11.

GENERAL NOTES:

5 5 10 15 20

1/8" = 1'-0"

FEETSCALE

C8C8

CC

BB

A8A8

8 9

9 9.2

9.2 9.8

9.82

A6A6

AA

GW

CAM

ROOM

9A-101

CLINICAL NURSE COORD.

9A-105

OFFICE

9A-103

NURSE MANAGER

9A-107

CHIEF NURSE

9A-109

OFFICE

9A-111

EXAM

9A-113

EXAM

9A-115

EXAM

9A-117

OFFICE

9A-119

OFFICE

9A-121

EXAM

9A-123

OFFICE

9A-131

STAIR #2

STAIR

CORRIDOR

9A-C1B

CORRIDOR

9A-C1C

CORR.

9A-C1

RECEPTION

9A-210

UNISEX TOILET

9B-200

EXISTING ELEV.

P-1

EXISTING ELEV.

P-2

EXISTING ELEV.

P-3

KEY PLAN

AREA A

PLAN NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

6 South Old Orchard Ave, Saint Louis, MO 63119 T: 800.404.7677 www.introba.com

B

IM

/2

V

A W e s t P a lm

B e a c h

E H

R M

I n fr a s tr u c tu re U p g ra d e s D e s ig n /5

-7

.B

.T

R

.r v t

/2

/2

:2

:1

A

M

B01-TN190B

NINTH LEVEL FLOOR PLAN - AREA

B - TELECOM

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

INFRASTRUCTURE UPGRADES

WEST PALM BEACH, FL

548-22-700

03/31/23 PR TL

B01

1/8" = 1'-0"1

NINTH LEVEL FLOOR PLAN - AREA B - TELECOM

1. EXISTING TELECOMMUNICATIONS ROOM.

2. EXISTING CONDITIONS WERE NOT OBSERVED ON SITE

VISITS, REFER TO AS BUILTS FOR DATA DEVICE LAYOUTS.

3. DATA OUTLET RELOCATED FROM DEMOLISHED WALL IN

NEW TR.

KEYED NOTES:#

1. REFER TO SHEET T-000 FOR GENERAL NOTES AND LEGENDS.

2. CONTRACTOR SHALL INSTALL BACKBONE RISER SLEEVES AND

CONDUITS OF THE SIZE AS INDICATED ON THE PLANS. REFER

TO SECTION 27 10 00 STRUCTURED CABLING AND SECTION 27

05 33 CONDUITS AND BOXES FOR COMMUNICATIONS

SYSTEMS.

3. CONTRACTOR SHALL X-RAY CONCRETE FLOOR BEFORE CORE

DRILLING. CONTRACTOR SHALL COORDINATE WITH THE COR

BEFORE BEGINNING DRILLING.

4. CONTRACTOR SHALL FIRESTOP RISER SLEEVES AND EMPTY

SPARE RISER SLEEVES. REFER TO SECTION 07 84 00

FIRESTOPPING.

5. CONTRACTOR SHALL INSTALL AN VERTICAL LADDER TYPE

CABLE TRAY ON THE WALL ABOVE THE VERTICAL RISER

SLEEVES FOR BACKBONE CABLE SUPPORT AS INDICATED ON

THE PLANS. THE CABLE TRAY SHALL BE SECURELY

ANCHORED TO THE WALL SUFFICIENT TO SUPPORT THE

TOTAL WEIGHT OF CABLES AND CABLE TRAY PLUS 50%.

6. CONTRACTOR SHALL INSTALL CABLE SUPPORTS SUFFICIENT

TO SUPPORT COMMUNICATIONS CABLES ON THE VERTICAL

CABLE TRAY WITHOUT DAMAGING OR DEFORMING THE CABLE.

7. CONTRACTOR SHALL INSTALL NEW J-HOOKS WHERE THERE IS

NO CABLE TRAY OR COMMUNICATIONS CONDUIT UNLESS

OTHERWISE NOTED.

8. CONTRACTOR SHALL INSTALL NEW CATEGORY 6A PATCH

PANELS IN THE TELECOMMUNICATION ROOM AS INDICATED ON

RACK ELEVATIONS.

9. CONTRACTOR SHALL RE-TERMINATE AND TEST CABLING

REMOVED FROM ANY WALL MOUNT EQUIPMENT UNLESS

OTHERWISE NOTED. TESTING SHALL BE PERFORMED BY THE

CONTRACTOR DURING COMMISSIONING.

10. CONTRACTOR SHALL INSTALL NEW CATEGORY 6A

TELECOMMUNICATIONS/DATA OUTLET AS INDICATED.

EXISTING COMMUNICATION OUTLET BOXES AND CONDUITS TO

BE REUSED.

11. CONTRACTOR SHALL REPLACE ALL DATA CABLE WITH NEW

CATEGORY 6A CABLE UNLESS OTHERWISE NOTED.

12. CONTRACTOR SHALL TERMINATE COMMUNICATIONS CABLES

WITH NEW CATEGORY MODULAR JACKS TO MATCH THE

COMMUNICATION CABLE PERFORMANCE SPECIFICATIONS.

NEW MODULAR JACKS SHALL BE OF THE SAME

MANUFACTURER AS THE FACE PLATES, PATCH PANELS, AND

PATCH CABLES.

13. CONTRACTOR SHALL INSTALL NEW CATEGORY 6A CABLES

AND CONNECTIVITY COMPONENTS THAT ARE OF THE SAME

MANUFACTURER, INCLUDING CABLE, MODULAR JACKS, PATCH

PANELS, FACEPLATES, AND PATCH CABLES.

14. CONTRACTOR SHALL TEST ALL NEW AND EXISTING RE-

TERMINATED CABLES IN ACCORDANCE WITH THE

SPECIFICATION 27 05 11.

GENERAL NOTES:

5 5 10 15 20

1/8" = 1'-0"

G8G8

GG

FF

EE

DD

C8C8

9.8

9.8 10.4

10.4

11.2

11.2 11.8

11.8

12.2

12.2

18 18.2

18.2

H4H4

CAM

CAM

CAM

CAM

CAM

CAM

GW

GW

GW

GW

EX

EX

5 5

5 5 5

1 1 1

1 1

1 1

1 1

1 1

1 1

UNISEX TOILET

9B-200

UNISEX TOILET

9B-202

FEMALE H.C. TOILET

9B-206

MALE H.C. TOILET

9B-204

CORRIDOR

9B-C7

EXISTING SOILED SERVICE LOBBY

9B-302

TEL.

9B-302C

CLEAN SERVICE LOBBY

9B-304

ELEVATOR SERVICE LOBBY

9B-306

EXISTING ELEV.

S-1

EXISTING ELEV.

S-2

EXISTING ELEV.

S-3

ELEV.

S-5

ELEV.

S-4

LIFT

MECHANICAL

9B-304A

STORAGE SUPPLY

9B-312

OFFICE PSYCHOLOGIST STORAGE

9B-314

EXISTING HAC

9B-316

EXAM

9B-320

EXAM

9B-322

OFFICE

9B-324

OFFICE

9B-326

EXAM

9B-328

EXAM

9B-330

EXAM

9B-332

EXAM

9B-334

OFFICE

9B-336

OFFICE

9B-338

EXAM

9B-340

EXAM

9B-342

EXAM

9B-344

EXAM

9B-346

OFFICE

9B-348

OFFICE

9B-350

EXAM

9B-352

EXAM

9B-354

STAFF LOCKERS

9B-356

STAFF LOUNGE / BREAK

9B-356B

STAFF TOILET

9B-356A

STAIR #6

STAIR

CORR.

9B-C7C

CORR.

9B-C7B

CORR.

9B-C7A

EXAM

9B-111

E.K.G. ROOM

9B-113

EXAM

9B-115

EXAM

9B-117

OFFICE

9B-119

OFFICE

9B-121

PACT SOCIAL WORKER

9B-123

EXAM

9B-125

EXAM

9B-127

EXAM

9B-129

OFFICE

9B-131

OFFICE

9B-133

EXAM

9B-135

EXAM

9B-137

EXAM

9B-139

EXAM

9B-141

OFFICE

9B-143

EXAM

9B-145

EXAM

9B-147

EXAM

9B-149

EXAM ROOM

9B-151

PRIMARY CARE EXAM

9B-153

PRIMARY CARE

9B-155

PRIMARY CARE EXAM

9B-157

OFFICE

9B-159

OFFICE

9B-161

EQUIP. ROOM

9B-163

NURSE MANAGER

9B-165

CORRIDOR

9B-C1B

CORRIDOR

9B-C1C

CORRIDOR

9B-C1D

CORRIDOR

9B-C1E

RECEPTION

9B-211

OFFICE

9B-212

NUTRITIONIST

9B-213

ALCOVE

9B-214

EXAM

9B-215

EXAM

9B-216

EXAM

9B-217

EXAM

9B-218

EXAM

9B-219

STAFF TOILET

9B-220

VITAL SIGNS STATION

9B-221

PROCEDURE ROOM

9B-222

MEDICATION

9B-223

PATIENT TOILET

9B-224

PATIENT TOILET

9B-225

SUPPLIES

9B-226

TR

9B-227

SOILED UTILITY

9B-228

ELECT.

9B-229

OFFICE

9B-230

OFFICE

9B-231

OFFICE

9B-233

EXAM

9B-235

ALCOVE

9B-236

WAITING

9B-201

PATIENT TOILET

9B-203

TELCOM.

9B-205

EQUIP. ALCOVE

9B-207

PATIENT TOILET

9B-208

SOCIAL WORKER

9B-209

OFFICE

9B-210

CLOSET

9B-210A

STORAGE

9B-212A

CORR.

9B-C2

PATIENT TOILET

9B-222A

PATIENT TOILET

9B-222B

CORRIDOR

9B-C7

B01-TN327

STORAGE

9B-304B

MECH.

9B-304C

KEY PLAN

AREA C

PLAN NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

6 South Old Orchard Ave, Saint Louis, MO 63119 T: 800.404.7677 www.introba.com

B

IM

/2

V

A W e s t P a lm

B e a c h

E H

R M

I n fr a s tr u c tu re U p g ra d e s D e s ig n /5

-7

.B

.T

R

.r v t

/2

/2

:2

:2

A

M

B01-TN190C

NINTH LEVEL FLOOR PLAN - AREA

C - TELECOM

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

INFRASTRUCTURE UPGRADES

WEST PALM BEACH, FL

548-22-700

03/31/23 PR TL

B01

1/8" = 1'-0"1

NINTH LEVEL FLOOR PLAN - AREA C - TELECOM

1. EXISTING TELECOMMUNICATIONS ROOM.

2. EXISTING CONDITIONS WERE NOT OBSERVED ON SITE

VISITS, REFER TO AS BUILTS FOR DATA DEVICE LAYOUTS.

3. DATA OUTLET RELOCATED FROM DEMOLISHED WALL IN

NEW TR.

KEYED NOTES:#

1. REFER TO SHEET T-000 FOR GENERAL NOTES AND LEGENDS.

2. CONTRACTOR SHALL INSTALL BACKBONE RISER SLEEVES AND

CONDUITS OF THE SIZE AS INDICATED ON THE PLANS. REFER

TO SECTION 27 10 00 STRUCTURED CABLING AND SECTION 27

05 33 CONDUITS AND BOXES FOR COMMUNICATIONS

SYSTEMS.

3. CONTRACTOR SHALL X-RAY CONCRETE FLOOR BEFORE CORE

DRILLING. CONTRACTOR SHALL COORDINATE WITH THE COR

BEFORE BEGINNING DRILLING.

4. CONTRACTOR SHALL FIRESTOP RISER SLEEVES AND EMPTY

SPARE RISER SLEEVES. REFER TO SECTION 07 84 00

FIRESTOPPING.

5. CONTRACTOR SHALL INSTALL AN VERTICAL LADDER TYPE

CABLE TRAY ON THE WALL ABOVE THE VERTICAL RISER

SLEEVES FOR BACKBONE CABLE SUPPORT AS INDICATED ON

THE PLANS. THE CABLE TRAY SHALL BE SECURELY

ANCHORED TO THE WALL SUFFICIENT TO SUPPORT THE

TOTAL WEIGHT OF CABLES AND CABLE TRAY PLUS 50%.

6. CONTRACTOR SHALL INSTALL CABLE SUPPORTS SUFFICIENT

TO SUPPORT COMMUNICATIONS CABLES ON THE VERTICAL

CABLE TRAY WITHOUT DAMAGING OR DEFORMING THE CABLE.

7. CONTRACTOR SHALL INSTALL NEW J-HOOKS WHERE THERE IS

NO CABLE TRAY OR COMMUNICATIONS CONDUIT UNLESS

OTHERWISE NOTED.

8. CONTRACTOR SHALL INSTALL NEW CATEGORY 6A PATCH

PANELS IN THE TELECOMMUNICATION ROOM AS INDICATED ON

RACK ELEVATIONS.

9. CONTRACTOR SHALL RE-TERMINATE AND TEST CABLING

REMOVED FROM ANY WALL MOUNT EQUIPMENT UNLESS

OTHERWISE NOTED. TESTING SHALL BE PERFORMED BY THE

CONTRACTOR DURING COMMISSIONING.

10. CONTRACTOR SHALL INSTALL NEW CATEGORY 6A

TELECOMMUNICATIONS/DATA OUTLET AS INDICATED.

EXISTING COMMUNICATION OUTLET BOXES AND CONDUITS TO

BE REUSED.

11. CONTRACTOR SHALL REPLACE ALL DATA CABLE WITH NEW

CATEGORY 6A CABLE UNLESS OTHERWISE NOTED.

12. CONTRACTOR SHALL TERMINATE COMMUNICATIONS CABLES

WITH NEW CATEGORY MODULAR JACKS TO MATCH THE

COMMUNICATION CABLE PERFORMANCE SPECIFICATIONS.

NEW MODULAR JACKS SHALL BE OF THE SAME

MANUFACTURER AS THE FACE PLATES, PATCH PANELS, AND

PATCH CABLES.

13. CONTRACTOR SHALL INSTALL NEW CATEGORY 6A CABLES

AND CONNECTIVITY COMPONENTS THAT ARE OF THE SAME

MANUFACTURER, INCLUDING CABLE, MODULAR JACKS, PATCH

PANELS, FACEPLATES, AND PATCH CABLES.

14. CONTRACTOR SHALL TEST ALL NEW AND EXISTING RE-

TERMINATED CABLES IN ACCORDANCE WITH THE

SPECIFICATION 27 05 11.

GENERAL NOTES:

5 5 10 15 20

1/8" = 1'-0"

C8C8

CC

BB

A8A8

9.8

9.8 10.4

10.4

11.2

11.2 11.8

11.8

12.2

12.2

18 18.2

18.2

A6A6

AA

GW

CAM

CAM

CAM

EX

2 2

EXISTING CORRIDOR

9B-C1

UNISEX TOILET

9B-200

UNISEX TOILET

9B-202

FEMALE H.C. TOILET

9B-206

MALE H.C. TOILET

9B-204

EXISTING ELEV.

P-1

EXISTING ELEV.

P-2

EXISTING ELEV.

P-3

EXISTING ELEV.

P-4

EXISTING ELEV.

P-5

STAIR #1

STAIR

CONFERENCE

9B-101

LIFT

OFFICE

9B-103

OFFICE

9B-105

OFFICE

9B-107

OFFICE

9B-109

EXAM

9B-111

E.K.G. ROOM

9B-113

EXAM

9B-115

EXAM

9B-117

OFFICE

9B-119

OFFICE

9B-121

PACT SOCIAL WORKER

9B-123

OFFICE

9B-131

CORRIDOR

9B-C1A

CORRIDOR

9B-C1B

RECEPTION

9B-211

KEY PLAN

AREA D

PLAN NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

6 South Old Orchard Ave, Saint Louis, MO 63119 T: 800.404.7677 www.introba.com

B

IM

/2

V

A W e s t P a lm

B e a c h

E H

R M

I n fr a s tr u c tu re U p g ra d e s D e s ig n /5

-7

.B

.T

R

.r v t

/2

/2

:2

:3

A

M

B01-TN190D

NINTH LEVEL FLOOR PLAN - AREA

D - TELECOM

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

INFRASTRUCTURE UPGRADES

WEST PALM BEACH, FL

548-22-700

03/31/23 PR TL

B01

1/8" = 1'-0"1

NINTH LEVEL FLOOR PLAN - AREA D - TELECOM

1. EXISTING TELECOMMUNICATIONS ROOM.

2. EXISTING CONDITIONS WERE NOT OBSERVED ON SITE

VISITS, REFER TO AS BUILTS FOR DATA DEVICE LAYOUTS.

3. DATA OUTLET RELOCATED FROM DEMOLISHED WALL IN

NEW TR.

KEYED NOTES:#

1. REFER TO SHEET T-000 FOR GENERAL NOTES AND LEGENDS.

2. CONTRACTOR SHALL INSTALL BACKBONE RISER SLEEVES AND

CONDUITS OF THE SIZE AS INDICATED ON THE PLANS. REFER

TO SECTION 27 10 00 STRUCTURED CABLING AND SECTION 27

05 33 CONDUITS AND BOXES FOR COMMUNICATIONS

SYSTEMS.

3. CONTRACTOR SHALL X-RAY CONCRETE FLOOR BEFORE CORE

DRILLING. CONTRACTOR SHALL COORDINATE WITH THE COR

BEFORE BEGINNING DRILLING.

4. CONTRACTOR SHALL FIRESTOP RISER SLEEVES AND EMPTY

SPARE RISER SLEEVES. REFER TO SECTION 07 84 00

FIRESTOPPING.

5. CONTRACTOR SHALL INSTALL AN VERTICAL LADDER TYPE

CABLE TRAY ON THE WALL ABOVE THE VERTICAL RISER

SLEEVES FOR BACKBONE CABLE SUPPORT AS INDICATED ON

THE PLANS. THE CABLE TRAY SHALL BE SECURELY

ANCHORED TO THE WALL SUFFICIENT TO SUPPORT THE

TOTAL WEIGHT OF CABLES AND CABLE TRAY PLUS 50%.

6. CONTRACTOR SHALL INSTALL CABLE SUPPORTS SUFFICIENT

TO SUPPORT COMMUNICATIONS CABLES ON THE VERTICAL

CABLE TRAY WITHOUT DAMAGING OR DEFORMING THE CABLE.

7. CONTRACTOR SHALL INSTALL NEW J-HOOKS WHERE THERE IS

NO CABLE TRAY OR COMMUNICATIONS CONDUIT UNLESS

OTHERWISE NOTED.

8. CONTRACTOR SHALL INSTALL NEW CATEGORY 6A PATCH

PANELS IN THE TELECOMMUNICATION ROOM AS INDICATED ON

RACK ELEVATIONS.

9. CONTRACTOR SHALL RE-TERMINATE AND TEST CABLING

REMOVED FROM ANY WALL MOUNT EQUIPMENT UNLESS

OTHERWISE NOTED. TESTING SHALL BE PERFORMED BY THE

CONTRACTOR DURING COMMISSIONING.

10. CONTRACTOR SHALL INSTALL NEW CATEGORY 6A

TELECOMMUNICATIONS/DATA OUTLET AS INDICATED.

EXISTING COMMUNICATION OUTLET BOXES AND CONDUITS TO

BE REUSED.

11. CONTRACTOR SHALL REPLACE ALL DATA CABLE WITH NEW

CATEGORY 6A CABLE UNLESS OTHERWISE NOTED.

12. CONTRACTOR SHALL TERMINATE COMMUNICATIONS CABLES

WITH NEW CATEGORY MODULAR JACKS TO MATCH THE

COMMUNICATION CABLE PERFORMANCE SPECIFICATIONS.

NEW MODULAR JACKS SHALL BE OF THE SAME

MANUFACTURER AS THE FACE PLATES, PATCH PANELS, AND

PATCH CABLES.

13. CONTRACTOR SHALL INSTALL NEW CATEGORY 6A CABLES

AND CONNECTIVITY COMPONENTS THAT ARE OF THE SAME

MANUFACTURER, INCLUDING CABLE, MODULAR JACKS, PATCH

PANELS, FACEPLATES, AND PATCH CABLES.

14. CONTRACTOR SHALL TEST ALL NEW AND EXISTING RE-

TERMINATED CABLES IN ACCORDANCE WITH THE

SPECIFICATION 27 05 11.

GENERAL NOTES:

5 5 10 15 20

1/8" = 1'-0"

G8G8

GG

FF

EE

DD

C8C8

CC

BB

A8A8

8 9

9 9.2

9.2 9.8

9.8 10.4

10.4

11.2

11.2 11.8

11.8

12.2

12.2

1818.2

18.2

19.6

19.6

19.8

19.8

20.8

20.821.2

21.2 22

A6A6

AA

H4H4

1 1

TR 1-9A-225 TR 1-9B-227

"x

"x

"x

"x

"x

"x

4"x4"

4"x4"

4"x4"

4"x4"

4"x4"

4"x4" 4"x4"

4"x4"

"x

"x

"x

"x

"x

"x

4"x4"

4"x4"

4"x4"

4"x4"

4"x4"

4"x4"

4"x4"

4"x4"

4"x4"

4"x4"

"x

"x

4"x4"

4"x4" 4"x4"

4"x4" 4 "x

"x

4"x4"

4"x4"

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

6 South Old Orchard Ave, Saint Louis, MO 63119 T: 800.404.7677 www.introba.com

B

IM

/2

V

A W e s t P a lm

B e a c h

E H

R M

I n fr a s tr u c tu re U p g ra d e s D e s ig n /5

-7

.B

.T

R

.r v t

/2

/2

:2

:2

A

M

B01-TN195

NINTH INT LEVEL OVERALL PLAN -

TELECOM

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

INFRASTRUCTURE UPGRADES

WEST PALM BEACH, FL

548-22-700

03/31/23 PR TL

B01

1" = 20'-0"1

NINTH INT LEVEL OVERALL PLAN - TELECOM

KEYED NOTES:#

1. EXISTING INTERSTITIAL CABLE TRAY

2. PROVIDE (1) 2" CONDUIT FROM EXISTING INTERSTITIAL

CABLE TRAY TO TR ON LEVEL BELOW FOR A-SIDE

BACKBONE PATHWAY.

3. PROVIDE (1) 2" CONDUIT FROM EXISTING INTERSTITIAL

CABLE TRAY TO TR ON LEVEL BELOW FOR B-SIDE

BACKBONE PATHWAY.

4. PROVIDE (1) 2" CONDUIT BETWEEN EXISTING

INTERSTITIAL CABLE TRAYS

PLAN NORTH

20 20 40

1" = 20'-0"

FEETSCALE

GENERAL NOTES:

7. GOVERNMENT EQUIPMENT WILL BE RELOCATED BY

GOVERNMENT IT PERSONNEL. CONTRACTOR WILL HAVE

TECHNICIANS AVAILABLE TO PROVIDE SUPPORT DURING

OUTAGES AND CUT-OVERS. COORDINATE WORK WITH

THE COR.

8. CONTRACTOR SHALL PROVIDE MTP, FIBER OPTIC TRUNK

CABLES FOR SIDE A AND SIDE B BACKBONE FROM THE

DATA CENTER TO EACH TELECOMMUNICATIONS ROOM.

COORDINATE WITH COR.

9. CONTRACTOR SHALL PROVIDE FIBER OPTIC PATCH

CABLES FOR SIDE A AND SIDE B FROM THE FIBER OPTIC

DISTRIBUTOR TO EQUIPMENT CABINETS. COORDINATE

WITH COR.

10. CONTRACTOR SHALL VERIFY FIBER OPTIC CABLES

MEASUREMENTS PRIOR TO ORDERING. COORDINATE WITH

COR.

11. PATHWAY SHOWN IN HALFTONE IS EXISTING AND SHALL

REMAIN IN PLACE. ROUTE NEW FIBER OPTIC BACKBONE

CABLING THROUGH EXISTING INFRASTRUCTURE AS

NOTED.

1. CONTRACTOR SHALL COORDINATE THE EQUIPMENT'S

INSTALLATION AND FINAL LOCATION WITH THE ELECTRICAL

AND MECHANICAL DIVISION. REFER TO ELECTRICAL,

MECHANICAL AND PLUMBING DRAWINGS.

2. CONTRACTOR SHALL INSTALL PATHWAY DIVIDERS, RADIUS

DROP, AND ANY OTHER FITTING FOR A PROPER CABLE

RUNWAY INSTALLATION.

3. CONTRACTOR SHALL COORDINATE THE HILTI SPEED

SLEEVE LOCATIONS WITH THE PATHWAY SYSTEM LAYOUT

OUTSIDE EACH TELECOM ROOM. REFER TO FLOOR PLAN

DRAWINGS.

4. CONTRACTOR SHALL INSTALL BACKBONE RISER SLEEVES

AND CONDUITS OF THE SIZE AS INDICATED ON THE PLANS.

REFER TO SECTION 27 10 00 STRUCTURED CABLING AND

SECTION 27 05 33 CONDUITS AND BOXES FOR

COMMUNICATIONS SYSTEMS.

5. CONTRACTOR SHALL X-RAY CONCRETE FLOOR BEFORE

CORE DRILLING. CONTRACTOR SHALL COORDINATE WITH

THE COR BEFORE BEGINNING DRILLING.

6. CONTRACTOR SHALL FIRESTOP RISER SLEEVES AND EMPTY

SPARE RISER SLEEVES. REFER TO SECTION 07 84 00

FIRESTOPPING.

14-122 NEW TR 14 1 3 1 2 1 --

16-M100 EXISTING TR 16 MEZZANINE 9 2 5 2 --

19-1H-103 EXISTING TR 19 1 4 1 2 1 --

22-154 EXISTING TR 22 1 8 1 4 2 --

TOTALS: 345 60 187 64 5

1-1C-140 NEW TR 1 1 13 2 7 2 --

1-2A-281 NEW TR 1 2 14 2 8 3 --

1-2B-205 NEW TR 1 2 23 2 12 4 --

1-2C-112 NEW TR 1 2 15 2 9 3 --

1-3A-320 NEW TR 1 3 12 2 6 2 --

1-3B-139A NEW TR 1 3 16 3 8 3 --

1-9B-227 NEW TR 1 9 11 2 6 2 --

1-BA-216 NEW TR 1 BASEMENT 18 3 9 3 --

1-BB-221 NEW TR 1 BASEMENT 13 2 7 2 --

1-BC-216 NEW TR 1 BASEMENT 8 1 4 2 --

1-BC-250 NEW TR 1 BASEMENT 13 2 7 2 --

1-6B-234 EXISTING TR 1 6 7 1 4 1 --

1-7A-235 EXISTING TR 1 7 6 1 3 1 --

1-7B-234 EXISTING TR 1 7 6 1 3 1 --

1-8A-222 NEW TR 1 8 11 2 6 2 --

1-8B-245 EXISTING TR 1 8 10 2 6 2 --

1-9A-225 NEW TR 1 9 9 1 5 2 --

1-4A-322 NEW TR 1 4 7 1 4 1 --

1-4B-252 NEW TR 1 4 15 2 9 3 --

1-4C-234 NEW TR 1 4 7 2 4 2 --

1-5A-235 EXISTING TR 1 5 6 1 3 1 --

1-5B-234 EXISTING TR 1 5 6 1 3 1 --

1-6A-235 EXISTING TR 1 6 6 2 3 1 --

3-1K-124D NEW TR 3 1 20 6 10 3 --

4-119 NEW TE 4 1 1 1 1 -- 1

6-222 EXISTING TE 6 1 1 1 1 -- 1

7-12 NEW TE 7 1 1 1 1 -- 1

10-2 NEW TR 10 1 2 1 1 1 --

12-12 NEW TR 12 1 4 1 2 1 --

TR EQUIPMENT SCHEDULE

ROOM # ROOM TYPE

BUILDING

MIN

PATCH

PANELS

MIN

VOICE

PATCH

PANEL

MIN

NETWORK

SWITCHES

REC

RACKS

REC

TEs

NUMBER LEVEL

1-1A-148 NEW TR 1 1 21 2 12 4 --

1-1B-238 NEW TR 1 1 17 2 9 3 --

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

6 South Old Orchard Ave, Saint Louis, MO 63119 T: 800.404.7677 www.introba.com

B

IM

/2

V

A W e s t P a lm

B e a c h

E H

R M

I n fr a s tr u c tu re U p g ra d e s D e s ig n /5

-7

.B

.T

R

.r v t

/2

/2

:2

:4

A

M

B01-TN300

TELECOMMUNICATIONS DATA

DEVICE SCHEDULE

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

INFRASTRUCTURE UPGRADES

WEST PALM BEACH, FL

548-22-700

03/31/23 PR TL

B01

TOTAL WAO/DATA DEVICES BY TR - BUILDING 01

TR ROOM LEVEL

# OF WAO

PORTS

ACTIVE DATA

WAO PORTS

ACTIVE VOICE

WAO PORTS

TR 1-1A-148 Level 1 986 249 57

TR 1-1B-238 Level 1 819 281 96

TR 1-1C-140 Level 1 604 125 70

TR 1-2A-281 Level 2 646 137 52

TR 1-2B-205 Level 2 1057 260 69

TR 1-2C-112 Level 2 695 218 96

TR 1-3A-320 Level 3 552 180 92

TR 1-3B-139A Level 3 739 187 130

TR 1-4A-324 Level 4 297 99 37

TR 1-4B-252 Level 4 689 163 79

TR 1-4C-234 Level 4 313 93 55

TR 1-5A-235 Level 5 264 29 19

TR 1-5B-234 Level 5 246 66 43

TR 1-6A-235 Level 6 258 80 56

TR 1-6B-234 Level 6 293 63 30

TR 1-7A-235 Level 7 253 80 14

TR 1-7B-234 Level 7 271 50 35

TR 1-8A-222 Level 8 503 125 91

TR 1-8B-245 Level 8 441 88 75

TR 1-9A-225 Level 9 432 73 48

TR 1-9B-227 Level 9 487 109 85

TR 1-BA-216 B15 Level 1 329 107 45

TR 1-BA-216 Basement 437 119 83

TR 1-BB-221 Basement 621 228 65

TR 1-BC-216 Basement 348 142 31

TR 1-BC-250 Basement 594 168 87

Grand total: 4617 13174 3519 1640

GENERAL NOTES:

1. CONTRACTOR SHALL COORDINATE THE EQUIPMENT'S INSTALLATION AND FINAL

LOCATION WITH THE ELECTRICAL AND MECHANICAL DIVISION. REFER TO ELECTRICAL,

MECHANICAL AND PLUMBING DRAWINGS.

2. CONTRACTOR SHALL INSTALL PATHWAY DIVIDERS, RADIUS DROP, AND ANY OTHER

FITTING FOR A PROPER CABLE RUNWAY INSTALLATION.

3. CONTRACTOR SHALL COORDINATE THE HILTI SPEED SLEEVE LOCATIONS WITH THE

PATHWAY SYSTEM LAYOUT OUTSIDE EACH TELECOM ROOM. REFER TO FLOOR PLAN

DRAWINGS.

4. CONTRACTOR SHALL INSTALL BACKBONE RISER SLEEVES AND CONDUITS OF THE

SIZE AS INDICATED ON THE PLANS. REFER TO SECTION 27 10 00 STRUCTURED

CABLING AND SECTION 27 05 33 CONDUITS AND BOXES FOR COMMUNICATIONS

SYSTEMS.

5. CONTRACTOR SHALL X-RAY CONCRETE FLOOR BEFORE CORE DRILLING.

CONTRACTOR SHALL COORDINATE WITH THE COR BEFORE BEGINNING DRILLING.

6. CONTRACTOR SHALL FIRESTOP RISER SLEEVES AND EMPTY SPARE RISER SLEEVES.

REFER TO SECTION 07 84 00 FIRESTOPPING.

7. GOVERNMENT EQUIPMENT WILL BE RELOCATED BY GOVERNMENT IT PERSONNEL.

CONTRACTOR WILL HAVE TECHNICIANS AVAILABLE TO PROVIDE SUPPORT DURING

OUTAGES AND CUT-OVERS. COORDINATE WORK WITH THE COR.

8. QUANTITIES OF ACTIVE DEVICES SHOWN IN THE SCHEDULE ARE BASED ON DEVICES

TERMINATED IN THE EXISTING WAO FACEPLATES. THE QUANTITY OF PATCH PANELS

SHOWN IN RACK ELEVATIONS IS BASED ON TOTAL NUMBER OF WAOs/DATA CABLES

PER TR AS SHOWN IN SCHEDULE. THE QUANTITY OF SWITCHES SHOWN IN RACK

ELEVATIONS IS BASED ON STANDARD 50% ACTIVE/PASSIVE RATIO WAO CALCULATION.

9. CONTRACTOR TO FIELD VERIFY DATA OUTLETS QUANTITIES IN FIELD PRIOR TO

INITIATING WORK. QUANTITIES OF WAO DEVICES AND WAO DEVICE CABLING IN FIELD

MAY VARY FROM DESIGN DRAWINGS. ANY VA OIT NETWORK WAO DEVICES NOT

SHOWN ON DRAWINGS SHOULD BE INCLUDED IN SCOPE OF THIS PROJECT UP TO A

QUANTITY OF 10% ADDITIONAL WAO DEVICES AND WAO DEVICE CABLING.

TR 1-BA-216 - TOTAL WAO/DATA DEVICES

TR ROOM LEVEL

# OF WAO

PORTS

ACTIVE DATA

WAO PORTS

ACTIVE VOICE

WAO PORTS

TR 1-BA-216 B15 Level 1 329 107 45

TR 1-BA-216 Basement 437 119 83

766 226 128

1. THIS TR SERVES BASEMENT LEVEL OF BUILDING 1 AND LEVEL 1 OF BUILDING 15.

KEYED NOTES:#

GROUP AA

B

GROUP B GROUP A GROUP B

LEG 1 LEG 2 LEG 1 LEG 2

OX

OZ

OY OZ OZ

OZOY

OY OYOX OX

OX

GROUP A GROUP B

LEG 1 LEG 2

OZ

OZ

OY OYOX

OX

C B

C

B

C B

C B

C

B

C B

C B

C

B

C B

C B

C

B

C B

C B

C

B

C B

C B

C

B

C B

EE

(2) SS24

(4) SS44

SBB

R A

C K

R

A C

K

R A

C K

13' - 3"

ELEC.

PANEL

ELEC.

PANEL

ACS PANEL

/4

/2

/4

13' - 3"

/2

/2

TR

BA-216

/2

B01-TN3013B01-TN301 21

"x

18"x4"

"x

18"x4"

"x

RACK 1 RACK 2 RACK 3

10 10 10 10

19 20

RACK 1RACK 2RACK 3

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

6 South Old Orchard Ave, Saint Louis, MO 63119 T: 800.404.7677 www.introba.com

B

IM

/2

V

A W e s t P a lm

B e a c h

E H

R M

I n fr a s tr u c tu re U p g ra d e s D e s ig n /5

-7

.B

.T

R

.r v t

/2

/2

:0

:4

A

M

B01-TN301

ENLARGED TELECOM PLANS -

1-BA-216

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

INFRASTRUCTURE UPGRADES

WEST PALM BEACH, FL

548-22-700

03/31/23 PR TL

B01

1/2" = 1'-0"1

BASEMENT LEVEL ENLARGED PLAN - 1-BA-216

1. HORIZONTAL CABLE MANAGER, SINGLE SIDED, 1 RU.

2. HORIZONTAL CABLE MANAGER, SINGLE SIDED, 2 RU.

3. PATCH PANEL, 48 PORT, 1 RU

4. ETHERNET SWITCH (GFGI)

5. FIBER OPTIC ENCLOSURE WITH DUPLEX-LC, MPO CASSETTES, 1 RU

6. SPACE RESERVED FOR RACK MOUNTED POWER EQUIPMENT.

7. ZONE PDU

8. PROVIDE A LOADED 48-PORT PATCH PANEL. PROVIDE 50-PAIR CAT3 CABLE FROM THE

CLOSEST SIGNALS CLOSET AND TERMINATE TO THIS PATCH PANEL. COORDINATE

TERMINATION OF THESE CABLES TO EXTEND THE EXISTING RISER CABLE INTO THE

NEW TR ROOMS. COORDINATE WITH FACILITIES ENGINEERING FOR TIMING, LOCATION

AND RE-LABELING THE RISER AT THE MDF ACCORDING TO THE CURRENT FACILITY

SCHEME.

9. PRIMARY PROTECTOR

10. VERTICAL CABLE MANAGEMENT

11. RACK-MOUNTED, 5KW, 208V, UPS WITH NEMA 20A, L21-20P INPUT AND L21-20R

OUTPUT.

12. VERTICAL RACK PDU, L21-20 PLUG, 3-PHASE WYE, 20A, 208V INPUT, (24) C13 (6) C19 (6)

5-20R OUTLETS, 208V OUTPUT.

13. SIDE-A POWER, L21-20R TWIST-LOCK RECEPTACLE 208V, 20A, THREE-PHASE CIRCUIT,

8.5 FT AFF, COORDINATE INSTALLATION LOCATION WITH CONTRACTOR.

14. SIDE-B POWER, L21-20R TWIST-LOCK RECEPTACLE 208V, 20A, THREE-PHASE CIRCUIT,

8.5 FT AFF, COORDINATE INSTALLATION LOCATION WITH CONTRACTOR.

15. 30 A, 208 V, 3-PHASE ZONE PDU BASE UNIT -REAR CIRCUITS WITH FOUR NEMA L21-20R

AND SIX NEMA 5-20 OUTLETS AND TWO 10' POWER CORDS TERMINATING IN NEMA

L21-30P.

16. SIDE-A POWER, L21-30R TWIST-LOCK RECEPTACLE 208V, 30A, THREE-PHASE CIRCUIT,

8.5 FT AFF, COORDINATE INSTALLATION LOCATION WITH CONTRACTOR.

17. SIDE-B POWER, L21-30R TWIST-LOCK RECEPTACLE 208V, 30A, THREE-PHASE CIRCUIT,

8.5 FT AFF, COORDINATE INSTALLATION LOCATION WITH CONTRACTOR.

18. 60 A, 208 V, 3-PHASE ZONE PDU BASE UNIT -REAR CIRCUITS WITH SIX NEMA L21-20R

OUTPUT RECEPTACLES AND TWO 10' POWER CORDS TERMINATING IN HARD-WIRED

JUNCTION BOX.

19. SIDE A POWER, REQUIRES A 208V, 60A, THREE-PHASE CIRCUIT TERMINATING IN A

HARD-WIRED JUNCTION BOX.

20. SIDE B POWER, REQUIRES A 208V, 60A, THREE-PHASE CIRCUIT TERMINATING IN A

HARD-WIRED JUNCTION BOX.

21. RACK BONDING BUSBAR (R.B.B.) FOR IT EQUIPMENT ONLY. NON-IT EQUIPMENT SHALL

NOT USE THE SAME BONDING BUSBAR.

22. 3/4" AC GRADE TRADE SIZE FIRE-RATED PLYWOOD BACKBOARD PAINTED HIGH-GLOSS

WHITE WITH TWO COATS OF FIRE-RESISTANT PAINT, 8" AFF. (TYP.)

23. SPACE RESERVED FOR BAS EQUIPMENT

KEYED NOTES:#

GENERAL NOTES:

N.T.S.2

1-BA-216 - RACK ELEVATIONS

PLAN NORTH

1 1 2 3 4 5

1/2" = 1'-0"

FEETSCALE

N.T.S.3

1-BA-216 - POWER ELEVATION AND SCHEMATIC

PRINT SHEET IN COLOR

1. CONTRACTOR SHALL COORDINATE THE EQUIPMENT'S INSTALLATION AND FINAL

LOCATION WITH THE ELECTRICAL AND MECHANICAL DIVISION. REFER TO ELECTRICAL,

MECHANICAL AND PLUMBING DRAWINGS.

2. CONTRACTOR SHALL INSTALL PATHWAY DIVIDERS, RADIUS DROP, AND ANY OTHER

FITTING FOR A PROPER CABLE RUNWAY INSTALLATION.

3. CONTRACTOR SHALL COORDINATE THE HILTI SPEED SLEEVE LOCATIONS WITH THE

PATHWAY SYSTEM LAYOUT OUTSIDE EACH TELECOM ROOM. REFER TO FLOOR PLAN

DRAWINGS.

4. CONTRACTOR SHALL INSTALL BACKBONE RISER SLEEVES AND CONDUITS OF THE

SIZE AS INDICATED ON THE PLANS. REFER TO SECTION 27 10 00 STRUCTURED

CABLING AND SECTION 27 05 33 CONDUITS AND BOXES FOR COMMUNICATIONS

SYSTEMS.

5. CONTRACTOR SHALL X-RAY CONCRETE FLOOR BEFORE CORE DRILLING.

CONTRACTOR SHALL COORDINATE WITH THE COR BEFORE BEGINNING DRILLING.

6. CONTRACTOR SHALL FIRESTOP RISER SLEEVES AND EMPTY SPARE RISER SLEEVES.

REFER TO SECTION 07 84 00 FIRESTOPPING.

7. PHASING OF THE WORK IN THE DATA CENTER IMPACTS WORK IN THE TRS AND

HORIZONTAL CABLING. COORDINATE WORK SCHEDULES WITH THE COR.

8. GOVERNMENT EQUIPMENT WILL BE RELOCATED BY GOVERNMENT IT PERSONNEL.

CONTRACTOR WILL HAVE TECHNICIANS AVAILABLE TO PROVIDE SUPPORT DURING

OUTAGES AND CUT-OVERS. COORDINATE WORK WITH THE COR.

9. CONTRACTOR SHALL PROVIDE CABLE MANAGEMENT FINGERS, AIR DAMS, BAYING

SEAL KITS, CABLE BRUSHES, AND GROMMETS MANUFACTURED AND COMPATIBLE

WITH CABINETS.

10. CONTRACTOR SHALL PROVIDE MTP, FIBER OPTIC TRUNK CABLES FOR SIDE A AND

SIDE B BACKBONE FROM THE DATA CENTER TO EACH TELECOMMUNICATIONS ROOM.

COORDINATE WITH COR.

11. CONTRACTOR SHALL PROVIDE FIBER OPTIC PATCH CABLES FOR SIDE A AND SIDE B

FROM THE FIBER OPTIC DISTRIBUTOR TO EQUIPMENT CABINETS. COORDINATE WITH

COR.

12. CONTRACTOR SHALL VERIFY FIBER OPTIC CABLES MEASUREMENTS PRIOR TO

ORDERING. COORDINATE WITH COR.

13. DEMOLISH ANY EXISTING TELECOMMUNICATIONS DATA DEVICE OUTLETS AND BACK

BOXES LOCATED IN NEW TELECOMMUNICATIONS ROOMS BACK TO SOURCE.

C

C

B

C B

C B

C

B

C B

C B

C

B

C B

C B

C

B

C B

GROUP AA

B

GROUP B GROUP A GROUP B

LEG 1 LEG 2 LEG 1 LEG 2

OX

OZ

OY OZ OZ

OZOY

OY OYOX OX

OX

FF

(4) SS44

/2

3' - 11 67/256"

3' - 3 101/128"

SBB

R A

C K

R

A C

K

ELEC.

PANEL

ELEC.

PANEL

A C

S P

A N

E L

TR

BB-221A

(4) SS44

/2

B01-TN302 3 B01-TN3022

"x

18"x4"

"x

"x

12"x4" 12"x4"

RACK 1 RACK 2

10 10 10

16 17

RACK 1RACK 2

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

6 South Old Orchard Ave, Saint Louis, MO 63119 T: 800.404.7677 www.introba.com

B

IM

/2

V

A W e s t P a lm

B e a c h

E H

R M

I n fr a s tr u c tu re U p g ra d e s D e s ig n /5

-7

.B

.T

R

.r v t

/2

/2

:0

:5

A

M

B01-TN302

ENLARGED TELECOM PLANS -

1-BB-221A

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

INFRASTRUCTURE UPGRADES

WEST PALM BEACH, FL

548-22-700

03/31/23 PR TL

B01

1/2" = 1'-0"1

BASEMENT LEVEL ENLARGED PLAN - 1-BB-221A

N.T.S.2

1-BB-221A - RACK ELEVATIONS

PLAN NORTH

1 1 2 3 4 5

1/2" = 1'-0"

FEETSCALE

N.T.S.3

1-BB-221A - POWER ELEVATION AND SCHEMATIC

PRINT SHEET IN COLOR

1. HORIZONTAL CABLE MANAGER, SINGLE SIDED, 1 RU.

2. HORIZONTAL CABLE MANAGER, SINGLE SIDED, 2 RU.

3. PATCH PANEL, 48 PORT, 1 RU

4. ETHERNET SWITCH (GFGI)

5. FIBER OPTIC ENCLOSURE WITH DUPLEX-LC, MPO CASSETTES, 1 RU

6. SPACE RESERVED FOR RACK MOUNTED POWER EQUIPMENT.

7. ZONE PDU

8. PROVIDE A LOADED 48-PORT PATCH PANEL. PROVIDE 50-PAIR CAT3 CABLE FROM THE

CLOSEST SIGNALS CLOSET AND TERMINATE TO THIS PATCH PANEL. COORDINATE

TERMINATION OF THESE CABLES TO EXTEND THE EXISTING RISER CABLE INTO THE

NEW TR ROOMS. COORDINATE WITH FACILITIES ENGINEERING FOR TIMING, LOCATION

AND RE-LABELING THE RISER AT THE MDF ACCORDING TO THE CURRENT FACILITY

SCHEME.

9. PRIMARY PROTECTOR

10. VERTICAL CABLE MANAGEMENT

11. RACK-MOUNTED, 5KW, 208V, UPS WITH NEMA 20A, L21-20P INPUT AND L21-20R

OUTPUT.

12. VERTICAL RACK PDU, L21-20 PLUG, 3-PHASE WYE, 20A, 208V INPUT, (24) C13 (6) C19 (6)

5-20R OUTLETS, 208V OUTPUT.

13. SIDE-A POWER, L21-20R TWIST-LOCK RECEPTACLE 208V, 20A, THREE-PHASE CIRCUIT,

8.5 FT AFF, COORDINATE INSTALLATION LOCATION WITH CONTRACTOR.

14. SIDE-B POWER, L21-20R TWIST-LOCK RECEPTACLE 208V, 20A, THREE-PHASE CIRCUIT,

8.5 FT AFF, COORDINATE INSTALLATION LOCATION WITH CONTRACTOR.

15. 30 A, 208 V, 3-PHASE ZONE PDU BASE UNIT -REAR CIRCUITS WITH FOUR NEMA L21-20R

AND SIX NEMA 5-20 OUTLETS AND TWO 10' POWER CORDS TERMINATING IN NEMA

L21-30P.

16. SIDE-A POWER, L21-30R TWIST-LOCK RECEPTACLE 208V, 30A, THREE-PHASE CIRCUIT,

8.5 FT AFF, COORDINATE INSTALLATION LOCATION WITH CONTRACTOR.

17. SIDE-B POWER, L21-30R TWIST-LOCK RECEPTACLE 208V, 30A, THREE-PHASE CIRCUIT,

8.5 FT AFF, COORDINATE INSTALLATION LOCATION WITH CONTRACTOR.

18. 60 A, 208 V, 3-PHASE ZONE PDU BASE UNIT -REAR CIRCUITS WITH SIX NEMA L21-20R

OUTPUT RECEPTACLES AND TWO 10' POWER CORDS TERMINATING IN HARD-WIRED

JUNCTION BOX.

19. SIDE A POWER, REQUIRES A 208V, 60A, THREE-PHASE CIRCUIT TERMINATING IN A

HARD-WIRED JUNCTION BOX.

20. SIDE B POWER, REQUIRES A 208V, 60A, THREE-PHASE CIRCUIT TERMINATING IN A

HARD-WIRED JUNCTION BOX.

21. RACK BONDING BUSBAR (R.B.B.) FOR IT EQUIPMENT ONLY. NON-IT EQUIPMENT SHALL

NOT USE THE SAME BONDING BUSBAR.

22. 3/4" AC GRADE TRADE SIZE FIRE-RATED PLYWOOD BACKBOARD PAINTED HIGH-GLOSS

WHITE WITH TWO COATS OF FIRE-RESISTANT PAINT, 8" AFF. (TYP.)

23. SPACE RESERVED FOR BAS EQUIPMENT

KEYED NOTES:#

GENERAL NOTES:

1. CONTRACTOR SHALL COORDINATE THE EQUIPMENT'S INSTALLATION AND FINAL

LOCATION WITH THE ELECTRICAL AND MECHANICAL DIVISION. REFER TO ELECTRICAL,

MECHANICAL AND PLUMBING DRAWINGS.

2. CONTRACTOR SHALL INSTALL PATHWAY DIVIDERS, RADIUS DROP, AND ANY OTHER

FITTING FOR A PROPER CABLE RUNWAY INSTALLATION.

3. CONTRACTOR SHALL COORDINATE THE HILTI SPEED SLEEVE LOCATIONS WITH THE

PATHWAY SYSTEM LAYOUT OUTSIDE EACH TELECOM ROOM. REFER TO FLOOR PLAN

DRAWINGS.

4. CONTRACTOR SHALL INSTALL BACKBONE RISER SLEEVES AND CONDUITS OF THE

SIZE AS INDICATED ON THE PLANS. REFER TO SECTION 27 10 00 STRUCTURED

CABLING AND SECTION 27 05 33 CONDUITS AND BOXES FOR COMMUNICATIONS

SYSTEMS.

5. CONTRACTOR SHALL X-RAY CONCRETE FLOOR BEFORE CORE DRILLING.

CONTRACTOR SHALL COORDINATE WITH THE COR BEFORE BEGINNING DRILLING.

6. CONTRACTOR SHALL FIRESTOP RISER SLEEVES AND EMPTY SPARE RISER SLEEVES.

REFER TO SECTION 07 84 00 FIRESTOPPING.

7. PHASING OF THE WORK IN THE DATA CENTER IMPACTS WORK IN THE TRS AND

HORIZONTAL CABLING. COORDINATE WORK SCHEDULES WITH THE COR.

8. GOVERNMENT EQUIPMENT WILL BE RELOCATED BY GOVERNMENT IT PERSONNEL.

CONTRACTOR WILL HAVE TECHNICIANS AVAILABLE TO PROVIDE SUPPORT DURING

OUTAGES AND CUT-OVERS. COORDINATE WORK WITH THE COR.

9. CONTRACTOR SHALL PROVIDE CABLE MANAGEMENT FINGERS, AIR DAMS, BAYING

SEAL KITS, CABLE BRUSHES, AND GROMMETS MANUFACTURED AND COMPATIBLE

WITH CABINETS.

10. CONTRACTOR SHALL PROVIDE MTP, FIBER OPTIC TRUNK CABLES FOR SIDE A AND

SIDE B BACKBONE FROM THE DATA CENTER TO EACH TELECOMMUNICATIONS ROOM.

COORDINATE WITH COR.

11. CONTRACTOR SHALL PROVIDE FIBER OPTIC PATCH CABLES FOR SIDE A AND SIDE B

FROM THE FIBER OPTIC DISTRIBUTOR TO EQUIPMENT CABINETS. COORDINATE WITH

COR.

12. CONTRACTOR SHALL VERIFY FIBER OPTIC CABLES MEASUREMENTS PRIOR TO

ORDERING. COORDINATE WITH COR.

13. DEMOLISH ANY EXISTING TELECOMMUNICATIONS DATA DEVICE OUTLETS AND BACK

C

B

C B

C B

C

B

C B

C B

C

B

C B

C B

C

B

C B

GROUP AA

B

GROUP B GROUP A GROUP B

LEG 1 LEG 2 LEG 1 LEG 2

OX

OZ

OY OZ OZ

OZOY

OY OYOX OX

OX

FF

19.6

19.6

19.8

19.8

RACK 1 RACK 2

/2

/2

5' - 4 3/4"

(4

S S

(2

S S

SBB17' - 4"

5' - 1"

ELEC.

PANEL

ELEC.

PANEL

ACS PANEL

TR

BC-216

B01-TN303

B01-TN303

12"x4"

"x

18"x4"

"x

12"x4"

"x

12"x4"

"x

RACK 1 RACK 2

10 10 10

16 17

RACK 1RACK 2

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

6 South Old Orchard Ave, Saint Louis, MO 63119 T: 800.404.7677 www.introba.com

B

IM

/2

V

A W e s t P a lm

B e a c h

E H

R M

I n fr a s tr u c tu re U p g ra d e s D e s ig n /5

-7

.B

.T

R

.r v t

/2

/2

:0

:0

A

M

B01-TN303

ENLARGED TELECOM PLANS -

1-BC-216

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

INFRASTRUCTURE UPGRADES

WEST PALM BEACH, FL

548-22-700

03/31/23 PR TL

B01

1/2" = 1'-0"1

BASEMENT LEVEL ENLARGED PLAN - 1-BC-216

N.T.S.2

1-BC-216 - RACK ELEVATIONS

PLAN NORTH

1 1 2 3 4 5

1/2" = 1'-0"

FEETSCALE

N.T.S.3

1-BC-216 - POWER ELEVATION AND SCHEMATIC

PRINT SHEET IN COLOR

1. HORIZONTAL CABLE MANAGER, SINGLE SIDED, 1 RU.

2. HORIZONTAL CABLE MANAGER, SINGLE SIDED, 2 RU.

3. PATCH PANEL, 48 PORT, 1 RU

4. ETHERNET SWITCH (GFGI)

5. FIBER OPTIC ENCLOSURE WITH DUPLEX-LC, MPO CASSETTES, 1 RU

6. SPACE RESERVED FOR RACK MOUNTED POWER EQUIPMENT.

7. ZONE PDU

8. PROVIDE A LOADED 48-PORT PATCH PANEL. PROVIDE 50-PAIR CAT3 CABLE FROM THE

CLOSEST SIGNALS CLOSET AND TERMINATE TO THIS PATCH PANEL. COORDINATE

TERMINATION OF THESE CABLES TO EXTEND THE EXISTING RISER CABLE INTO THE

NEW TR ROOMS. COORDINATE WITH FACILITIES ENGINEERING FOR TIMING, LOCATION

AND RE-LABELING THE RISER AT THE MDF ACCORDING TO THE CURRENT FACILITY

SCHEME.

9. PRIMARY PROTECTOR

10. VERTICAL CABLE MANAGEMENT

11. RACK-MOUNTED, 5KW, 208V, UPS WITH NEMA 20A, L21-20P INPUT AND L21-20R

OUTPUT.

12. VERTICAL RACK PDU, L21-20 PLUG, 3-PHASE WYE, 20A, 208V INPUT, (24) C13 (6) C19 (6)

5-20R OUTLETS, 208V OUTPUT.

13. SIDE-A POWER, L21-20R TWIST-LOCK RECEPTACLE 208V, 20A, THREE-PHASE CIRCUIT,

8.5 FT AFF, COORDINATE INSTALLATION LOCATION WITH CONTRACTOR.

14. SIDE-B POWER, L21-20R TWIST-LOCK RECEPTACLE 208V, 20A, THREE-PHASE CIRCUIT,

8.5 FT AFF, COORDINATE INSTALLATION LOCATION WITH CONTRACTOR.

15. 30 A, 208 V, 3-PHASE ZONE PDU BASE UNIT -REAR CIRCUITS WITH FOUR NEMA L21-20R

AND SIX NEMA 5-20 OUTLETS AND TWO 10' POWER CORDS TERMINATING IN NEMA

L21-30P.

16. SIDE-A POWER, L21-30R TWIST-LOCK RECEPTACLE 208V, 30A, THREE-PHASE CIRCUIT,

8.5 FT AFF, COORDINATE INSTALLATION LOCATION WITH CONTRACTOR.

17. SIDE-B POWER, L21-30R TWIST-LOCK RECEPTACLE 208V, 30A, THREE-PHASE CIRCUIT,

8.5 FT AFF, COORDINATE INSTALLATION LOCATION WITH CONTRACTOR.

18. 60 A, 208 V, 3-PHASE ZONE PDU BASE UNIT -REAR CIRCUITS WITH SIX NEMA L21-20R

OUTPUT RECEPTACLES AND TWO 10' POWER CORDS TERMINATING IN HARD-WIRED

JUNCTION BOX.

19. SIDE A POWER, REQUIRES A 208V, 60A, THREE-PHASE CIRCUIT TERMINATING IN A

HARD-WIRED JUNCTION BOX.

20. SIDE B POWER, REQUIRES A 208V, 60A, THREE-PHASE CIRCUIT TERMINATING IN A

HARD-WIRED JUNCTION BOX.

21. RACK BONDING BUSBAR (R.B.B.) FOR IT EQUIPMENT ONLY. NON-IT EQUIPMENT SHALL

NOT USE THE SAME BONDING BUSBAR.

22. 3/4" AC GRADE TRADE SIZE FIRE-RATED PLYWOOD BACKBOARD PAINTED HIGH-GLOSS

WHITE WITH TWO COATS OF FIRE-RESISTANT PAINT, 8" AFF. (TYP.)

23. SPACE RESERVED FOR BAS EQUIPMENT

KEYED NOTES:#

GENERAL NOTES:

1. CONTRACTOR SHALL COORDINATE THE EQUIPMENT'S INSTALLATION AND FINAL

LOCATION WITH THE ELECTRICAL AND MECHANICAL DIVISION. REFER TO ELECTRICAL,

MECHANICAL AND PLUMBING DRAWINGS.

2. CONTRACTOR SHALL INSTALL PATHWAY DIVIDERS, RADIUS DROP, AND ANY OTHER

FITTING FOR A PROPER CABLE RUNWAY INSTALLATION.

3. CONTRACTOR SHALL COORDINATE THE HILTI SPEED SLEEVE LOCATIONS WITH THE

PATHWAY SYSTEM LAYOUT OUTSIDE EACH TELECOM ROOM. REFER TO FLOOR PLAN

DRAWINGS.

4. CONTRACTOR SHALL INSTALL BACKBONE RISER SLEEVES AND CONDUITS OF THE

SIZE AS INDICATED ON THE PLANS. REFER TO SECTION 27 10 00 STRUCTURED

CABLING AND SECTION 27 05 33 CONDUITS AND BOXES FOR COMMUNICATIONS

SYSTEMS.

5. CONTRACTOR SHALL X-RAY CONCRETE FLOOR BEFORE CORE DRILLING.

CONTRACTOR SHALL COORDINATE WITH THE COR BEFORE BEGINNING DRILLING.

6. CONTRACTOR SHALL FIRESTOP RISER SLEEVES AND EMPTY SPARE RISER SLEEVES.

REFER TO SECTION 07 84 00 FIRESTOPPING.

7. PHASING OF THE WORK IN THE DATA CENTER IMPACTS WORK IN THE TRS AND

HORIZONTAL CABLING. COORDINATE WORK SCHEDULES WITH THE COR.

8. GOVERNMENT EQUIPMENT WILL BE RELOCATED BY GOVERNMENT IT PERSONNEL.

CONTRACTOR WILL HAVE TECHNICIANS AVAILABLE TO PROVIDE SUPPORT DURING

OUTAGES AND CUT-OVERS. COORDINATE WORK WITH THE COR.

9. CONTRACTOR SHALL PROVIDE CABLE MANAGEMENT FINGERS, AIR DAMS, BAYING

SEAL KITS, CABLE BRUSHES, AND GROMMETS MANUFACTURED AND COMPATIBLE

WITH CABINETS.

10. CONTRACTOR SHALL PROVIDE MTP, FIBER OPTIC TRUNK CABLES FOR SIDE A AND

SIDE B BACKBONE FROM THE DATA CENTER TO EACH TELECOMMUNICATIONS ROOM.

COORDINATE WITH COR.

11. CONTRACTOR SHALL PROVIDE FIBER OPTIC PATCH CABLES FOR SIDE A AND SIDE B

FROM THE FIBER OPTIC DISTRIBUTOR TO EQUIPMENT CABINETS. COORDINATE WITH

COR.

12. CONTRACTOR SHALL VERIFY FIBER OPTIC CABLES MEASUREMENTS PRIOR TO

ORDERING. COORDINATE WITH COR.

13. DEMOLISH ANY EXISTING TELECOMMUNICATIONS DATA DEVICE OUTLETS AND BACK

C

B

C B

C B

C

B

C B

C B

C

B

C B

C B

C

B

C B

GROUP AA

B

GROUP B GROUP A GROUP B

LEG 1 LEG 2 LEG 1 LEG 2

OX

OZ

OY OZ OZ

OZOY

OY OYOX OX

OX

FF

SBB

(4) SS44

(4) SS44

RACK 1

/1

/2

RACK 2

3' - 7 177/256"

9' - 11 1/8"

TR

BC-250

ACS PANEL

ELEC.

PANEL

ELEC.

PANEL

1' - 8 111/256"

B01-TN304

B01-TN304

12"x4"

"x

18"x4"

"x

12"x4"

RACK 1 RACK 2

10 10 10

16 17

RACK 1RACK 2

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% FINAL STAMPED

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

10360 Ellison Circle Omaha, NE 68134 Phone: 402.991.5520 www.specializedeng.com

6 South Old Orchard Ave, Saint Louis, MO 63119 T: 800.404.7677 www.introba.com

B

IM

/2

V

A W e s t P a lm

B e a c h

E H

R M

I n fr a s tr u c tu re U p g ra d e s D e s ig n /5

-7

.B

.T

R

.r v t

/2

/2

:0

:1

A

M

B01-TN304

ENLARGED TELECOM PLANS -

1-BC-250

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

INFRASTRUCTURE UPGRADES

WEST PALM BEACH, FL

548-22-700

03/31/23 PR TL

B01

1/2" = 1'-0"1

BASEMENT LEVEL ENLARGED PLAN - 1-BC-250

N.T.S.2

1-BC-250 - RACK ELEVATIONS

PLAN NORTH

1 1 2 3 4 5

1/2" = 1'-0"

FEETSCALE

N.T.S.3

1-BC-250 - POWER ELEVATION AND SCHEMATIC

PRINT SHEET IN COLOR

1. HORIZONTAL CABLE MANAGER, SINGLE SIDED, 1 RU.

2. HORIZONTAL CABLE MANAGER, SINGLE SIDED, 2 RU.

3. PATCH PANEL, 48 PORT, 1 RU

4. ETHERNET SWITCH (GFGI)

5. FIBER OPTIC ENCLOSURE WITH DUPLEX-LC, MPO CASSETTES, 1 RU

6. SPACE RESERVED FOR RACK MOUNTED POWER EQUIPMENT.

7. ZONE PDU

8. PROVIDE A LOADED 48-PORT PATCH PANEL. PROVIDE 50-PAIR CAT3 CABLE FROM THE

CLOSEST SIGNALS CLOSET AND TERMINATE TO THIS PATCH PANEL. COORDINATE

TERMINATION OF THESE CABLES TO EXTEND THE EXISTING RISER CABLE INTO THE

NEW TR ROOMS. COORDINATE WITH FACILITIES ENGINEERING FOR TIMING, LOCATION

AND RE-LABELING THE RISER AT THE MDF ACCORDING TO THE CURRENT FACILITY

SCHEME.

9. PRIMARY PROTECTOR

10. VERTICAL CABLE MANAGEMENT

11. RACK-MOUNTED, 5KW, 208V, UPS WITH NEMA 20A, L21-20P INPUT AND L21-20R

OUTPUT.

12. VERTICAL RACK PDU, L21-20 PLUG, 3-PHASE WYE, 20A, 208V INPUT, (24) C13 (6) C19 (6)

5-20R OUTLETS, 208V OUTPUT.

13. SIDE-A POWER, L21-20R TWIST-LOCK RECEPTACLE 208V, 20A, THREE-PHASE CIRCUIT,

8.5 FT AFF, COORDINATE INSTALLATION LOCATION WITH CONTRACTOR.

14. SIDE-B POWER, L21-20R TWIST-LOCK RECEPTACLE 208V, 20A, THREE-PHASE CIRCUIT,

8.5 FT AFF, COORDINATE INSTALLATION LOCATION WITH CONTRACTOR.

15. 30 A, 208 V, 3-PHASE ZONE PDU BASE UNIT -REAR CIRCUITS WITH FOUR NEMA L21-20R

AND SIX NEMA 5-20 OUTLETS AND TWO 10' POWER CORDS TERMINATING IN NEMA

L21-30P.

16. SIDE-A POWER, L21-30R TWIST-LOCK RECEPTACLE 208V, 30A, THREE-PHASE CIRCUIT,

8.5 FT AFF, COORDINATE INSTALLATION LOCATION WITH CONTRACTOR.

17. SIDE-B POWER, L21-30R TWIST-LOCK RECEPTACLE 208V, 30A, THREE-PHASE CIRCUIT,

8.5 FT AFF, COORDINATE INSTALLATION LOCATION WITH CONTRACTOR.

18. 60 A, 208 V, 3-PHASE ZONE PDU BASE UNIT -REAR CIRCUITS WITH SIX NEMA L21-20R

OUTPUT RECEPTACLES AND TWO 10' POWER CORDS TERMINATING IN HARD-WIRED

JUNCTION BOX.

19. SIDE A POWER, REQUIRES A 208V, 60A, THREE-PHASE CIRCUIT TERMINATING IN A

HARD-WIRED JUNCTION BOX.

20. SIDE B POWER, REQUIRES A 208V, 60A, THREE-PHASE CIRCUIT TERMINATING IN A

HARD-WIRED JUNCTION BOX.

21. RACK BONDING BUSBAR (R.B.B.) FOR IT EQUIPMENT ONLY. NON-IT EQUIPMENT SHALL

NOT USE THE SAME BONDING BUSBAR.

22. 3/4" AC GRADE TRADE SIZE FIRE-RATED PLYWOOD BACKBOARD PAINTED HIGH-GLOSS

WHITE WITH TWO COATS OF FIRE-RESISTANT PAINT, 8" AFF. (TYP.)

23. SPACE RESERVED FOR BAS EQUIPMENT

KEYED NOTES:#

GENERAL NOTES:

1. CONTRACTOR SHALL COORDINATE THE EQUIPMENT'S INSTALLATION AND FINAL

LOCATION WITH THE ELECTRICAL AND MECHANICAL DIVISION. REFER TO ELECTRICAL,

MECHANICAL AND PLUMBING DRAWINGS.

2. CONTRACTOR SHALL INSTALL PATHWAY DIVIDERS, RADIUS DROP, AND ANY OTHER

FITTING FOR A PROPER CABLE RUNWAY INSTALLATION.

3. CONTRACTOR SHALL COORDINATE THE HILTI SPEED SLEEVE LOCATIONS WITH THE

PATHWAY SYSTEM LAYOUT OUTSIDE EACH TELECOM ROOM. REFER TO FLOOR PLAN

DRAWINGS.

4. CONTRACTOR SHALL INSTALL BACKBONE RISER SLEEVES AND CONDUITS OF THE

SIZE AS INDICATED ON THE PLANS. REFER TO SECTION 27 10 00 STRUCTURED

CABLING AND SECTION 27 05 33 CONDUITS AND BOXES FOR COMMUNICATIONS

SYSTEMS.

5. CONTRACTOR SHALL X-RAY CONCRETE FLOOR BEFORE CORE DRILLING.

CONTRACTOR SHALL COORDINATE WITH THE COR BEFORE BEGINNING DRILLING.

6. CONTRACTOR SHALL FIRESTOP RISER SLEEVES AND EMPTY SPARE RISER SLEEVES.

REFER TO SECTION 07 84 00 FIRESTOPPING.

7. PHASING OF THE WORK IN THE DATA CENTER IMPACTS WORK IN THE TRS AND

HORIZONTAL CABLING. COORDINATE WORK SCHEDULES WITH THE COR.

8. GOVERNMENT EQUIPMENT WILL BE RELOCATED BY GOVERNMENT IT PERSONNEL.

CONTRACTOR WILL HAVE TECHNICIANS AVAILABLE TO PROVIDE SUPPORT DURING

OUTAGES AND CUT-OVERS. COORDINATE WORK WITH THE COR.

9. CONTRACTOR SHALL PROVIDE CABLE MANAGEMENT FINGERS, AIR DAMS, BAYING

SEAL KITS, CABLE BRUSHES, AND GROMMETS MANUFACTURED AND COMPATIBLE

WITH CABINETS.

10. CONTRACTOR SHALL PROVIDE MTP, FIBER OPTIC TRUNK CABLES FOR SIDE A AND

SIDE B BACKBONE FROM THE DATA CENTER TO EACH TELECOMMUNICATIONS ROOM.

COORDINATE WITH COR.

1…